NCL30160GEVB_TEST_PROCEDURE.PDF - 1692.0 KB

Test Procedure for the NC30160GEVB
03/7/2012
Agilent E3632A
DC Power Supply
Chroma 63106
Chroma 6312
+ -
Agilent 34401A Multimeter
HI
HI
LO
+
LO
I
05/15/2012
1
www.onsemi.com
Table 1: Required Equipment
Agilent E3632A DC Power
Agilent 34401A Multimeter
Supply
Two Black Test Leads
Chroma 6312 Electronic Load
Mainframe
One NCL30160GEVB
Evaluation Board
Three Red Test Leads
Chroma 63106 Electronic
Load
Test Procedure:
1. Connect the test setup as shown above.
2. Apply an input voltage, VIN = 12V across VIN and GND.
3. Apply 10 Ω loading from the electronic load after powering up the demo board.
4. Check IOUT.
5. Change the VIN voltage to VIN = 24V.
6. Check IOUT.
05/15/2012
2
www.onsemi.com
Table 2: Desired Results
For VIN = 12V,
IOUT = 280 mA
For VIN = 24V,
IOUT = 277 mA
05/15/2012
3
www.onsemi.com