NCP1030GEVB_TEST_PROCEDURE.PDF - 1654.0 KB

Test Procedure for the NCP 1030EVB
08/03/2004
08/03/2004
1
www.onsemi.com
Table 1: Required Equipment
Equipment
Dual Channel Oscilloscope
Keithley 179A Multimeter or Similar
Test Leads
Positive and Negative Probe Leads for the Oscilloscope
KIKUSUI PLZ303W Load
(76V, 1A) Power Supply
NCP1030 Evaluation Board
Quantity
1
4
4
1
1
1
1
Test Procedure:
1. Connect the test setup as shown above.
2. Apply an input voltage, VIN = 25V across J1 and J2.
3. Check the switching waveform at scope CH1 to see whether the start-up circuit is enabled.
4. Apply an input voltage, VIN = 36 V across J1 and J2. Measure the output voltage across J4 and J3. It
should be approximately 12 V.
5. Apply 175 mA loading from the electronic load after powering up the demo board.
6. Measure VIN, IIN, IOUT, VOUT.
7. Increase VIN to 80 V. The output should turn OFF.
08/03/2004
2
www.onsemi.com
VIN = 36 V
Table 2: Desired Results
IIN = 70 mA to 80 mA
VOUT = 11.1 V to 11.5 V
VIN = 48 V
IIN = 50 mA to 60 mA
VOUT = 11.1 V to 11.5 V
VIN = 76 V
IIN = 30 mA to 40 mA
VOUT = 11.0 V to 11.5 V
08/03/2004
3
www.onsemi.com