NCP1400AV19EVB_TEST_PROCEDURE.PDF - 87.0 KB

NCP1400A Demo Board Test Procedure
Demo Board
+Vs
Power Supply
w/ 4 wires
sensing
L
+V
-V
IOUT
Electronic Load
TP2
TP1
IIN
VIN
V
VOUT
IOUT = 10 mA
TP4
V
mA
-VS
TP3
OFF
ON
Oscilloscope Setting
Oscilloscope
Ch1
Ch1: 1 V/div (DC-coupled)
Ch2: 20 mV/div (AC-coupled)
Time base: 2 µs/div
Ch2
1. Connect the test setup as shown above.
2. Apply an input voltage, VIN = 1.5 V across TP1 and TP4.
3. Set the electronic load to 10 mA.
4. Check IIN, VOUT, and output Vripple;
Device Voltage
IIN (V); Min / Max Range
VOUT ; Min / Max Range
Option
1.9 V
15.4 mA to 16.3 mA
1.853 V to 1.948 V
2.5 V
20.3 mA to 21.4 mA
2.438 V to 2.563 V
2.7 V
21.9 mA to 23.1 mA
2.633 V to 2.768 V
3.0 V
24.4 mA to 25.7 mA
2.925 V to 3.075 V
3.3 V
26.8 mA to 28.2 mA
3.218 V to 3.383 V
5.0 V
40.6 mA to 42.8 mA
4.875 V to 5.125 V
5.
VRIPPLE ; Typical
11 mVP-P
12 mVP-P
13 mVP-P
15 mVP-P
16 mVP-P
17 mVP-P
Check the switching waveform at scope Ch1 to see whether it is a normal discontinuous conduction mode
switching node voltage waveform. And check the frequency of the waveform, FSW, it should be 144 kHz to
216 kHz.