NCP1337ADAPGEVB_TEST_PROCEDURE.PDF - 182.0 KB

Test Procedure for the NCP1337 Adapter Evaluation Board
Electronic Load
Setup 5A Current Mode
Figure 1 - Test Setup
9/21/2007
-1-
Table of Required Equipment
AC Power Supply, 85-265Vac 1A
YOKOGAWA Power Meter WT210
Multimeter
Electronic Load
Test Procedure:
1. Connect the test setup as showed above in Figure 1.
2. Apply an input voltage, 85Vac < Vin < 265Vac, 50Hz or 60Hz
3. Measure Vout and Efficiency to compare with the table of desired results.
Desired Results
Measurements
1
Conditions
Comments
Pin < 0.3W
4
Vin = 230 Vac
Iout = 0A
Efficiency and Vout at high line and full load Vin = 230 Vac
Iout = 5A
Efficiency and Vout at low line and full load Vin = 100 Vac
Iout = 5A
Brown out: Turn off level
Iout = 5A
5
Brown out: Turn on level
Iout = 5A
Vin = 75-85 Vac
6
Overpower Protection at high line
Vin = 230 Vac Iout < 7Amax
Power come into auto restart mode
7
Output over voltage protection at high line
Vin = 230 Vac Power latch off
Short circuit of opto-coupler U1 pin1 to
Pin2
2
3
Standby input power at high line
Results
9/21/2007
Output no load
Efficiency > 88% Efficiency = (Pout/Pin)*100
Vout = 12V ± 5%
Efficiency > 84% Efficiency = (Pout/Pin)*100
Vout = 12V ± 5%
Vin = 65-75 Vac
-2-