NCP1581SBCKRGEVB_TEST_PROCEDURE.PDF - 728.0 KB

Test Procedure for the NCP1581SBCKRGEVB Evaluation Board
Figure 1: Test Setup
The following steps describe the test procedure for all these boards:
Required Equipment:
Current limited DC Power Supply (e.g. AGILENT 6645A) ……………………… 2 pcs
DC Volt-Meter able to measure up to 20 V DC (e.g. KEITHLEY 2000) …….……3 pcs
DC Amp-Meter able to measure up to 1 A DC (e.g. KEITHLEY 2000) ………......1 pc
DC Amp-Meter able to measure up to 10 A DC (e.g. FLUKE 89 IV)…………… 2 pcs
DC Electronic Load (e.g. AGILENT 6060B) ……………………………………... 1 pc
Test Procedure:
1. Connect the test setup as shown in Figure 1.
2. Apply an VCC voltage, VCC = 12 V
3. Apply an VIN voltage, VIN = 5 V
4. Check that VOUT = 1.1 – 3 V (can be set by trimmer)
5. Set IOUT = 10 A
6. Check that VOUT = 1.1 – 3 V (can be set by trimmer)
7. Turn off the load
8. Turn off VCC
9. Turn off VIN
10. End of the test
5/24/2010
-1-