Test Procedure for the NCP3063 Boost – DFN 9/27/2006 Figure 1: Test Setup DFN Table 1: Required Equipment Voltage Supply (12V, 3A) Voltage Meter Electronic Load Test Procedure: 1. Connect the test setup as shown in Figure 1. 2. Apply an input voltage, Vcc = 12V 3. Apply Iout = 0mA load. 4. Check that Vout is 24Vdc (23.9V – 24.1V) 5. Increase Iout load to 350mA 6. Check that Vout is 24V (23.9V – 24.1V) 7. Power down the load 8. Power down Vcc 9. End of test