NCP3063SMDBSTEVB_TEST_PROCEDURE.PDF - 305.0 KB

Test Procedure for the NCP3063 (SOIC-8) Boost Evaluation Board
Figure 1Test Setup
Table 1 Required Equipment
Voltage Supply (12V, 3A)
Voltage Meter
Electronic Load or Current
Source
Test Procedure:
1. Connect the test setup as shown in Figure 1
2. Apply an input voltage, Vcc = 12V
3. Apply Iout = 0A load
4. Check that Vout is 24V (23.9V-24.1V)
5. Increase Iout load to 350mA
6. Check that Vout is 24V (23.9V-24.1V)
7. Power down the load
8. Power down Vcc
9. End of test
3/13/2008
-1-
www.onsemi.com