Test Procedure for the NCP374MU075GEVB Evaluation Board
Connecting Process
1. Place /EN strap and /DIR strap on left side (“1” logic) (connected to Vbat, through pull up
resistor)
2. Connect a Battery or power supply (4.2V) on Battery test point. (min 2A capability)
3. Let Battery strap opened.
05/11/2016
1
www.onsemi.com
4. Connect strap on Ilim.
05/11/2016
2
www.onsemi.com
Disable Mode:
5. Connect 10 V capability Vin Supply on IN1 test point.
a. Set power supply to 5V Check OUT1 = 0V and LED = off
05/11/2016
3
www.onsemi.com
Direct Mode:
6. Switch /DIR from left to right, 1 logic level to 0 logic level
05/11/2016
4
www.onsemi.com
7. Check OUT1=5V and Flag LED is still off
8. Set Vin=7V
9. Check Flag LED = on, and OUT1 is 0V.
Disconnect IN1 supply
Reverse Mode:
10. Set /DIR=1, /EN=1
Disconnect Vin Power Supply from IN1 test point.
Connect 100 ohms on IN1 test point.
Connect Strap on OUT.
11. Set /DIR=1, /EN=0: Vout= Vin
Power off.
12. Set /DIR=1, /EN=1
13. Disconnect load on IN1
14. Disconnect B+ supply
Please contact Application Engineer for further information.