NCP5212AGEVB_TEST_PROCEDURE.PDF - 106.0 KB

Test Procedure for the NCP5212AGEVB Evaluation Board
CRO
PSU1
20V/2A
V
Vo
e-Load
0~15A
PSU2
5V/0.1A
Equipment Set Up Diagram
4/24/2010
Page 1 of 5
www.onsemi.com
Demonstration Board Jumper Location Map
JP3: EN
Default = open
JP2: Sync
Default = open
JP1: Mode Selection
OCP only (Default)
OCP + AVP
4/24/2010
Page 2 of 5
www.onsemi.com
Equipment List
Item
1
2
3
4
Qty
1
2
1
1
Description
Electronic Load. KIKUSUI-PLZ153W or equivalent.
Power Supply. AGILENT-E3632A or equivalent. (Note: build-in ammeter)
Digital Multimeter. AGILENT-34401A or equivalent.
Tekronix TDS460A CRO or equivalent.
Demonstration Board Jumper Setting
Jumper
Status
JP1
-
JP2
-
JP3
-
Description
Sync (not used for demo board test)
Default = open
Mode selection
Default = see “Demo board jumper location map” diagram
Device enable pin.
Open = device is operating
Short = device shut down
Default = open
Demonstration Board Terminal Pins List
Terminal
VIN
PGND
+5V
AGND
4/24/2010
Description
Device input voltage (5-27V)
Device power ground
Device analog circuit bias (4.5 ~ 5.5V)
Device analog ground
Page 3 of 5
www.onsemi.com
Test Procedures
1.
2.
3.
4.
All Jumpers are set as “Default”
Set up the demonstration board shown at “Equipment Set Up Diagram”
Set PSU1=20V, PSU2=5V. For safety set current limit of PSU1=2A, PSU2=0.1A
Measuring results are tabulated in the following table
Note: PSU = Power Supply Unit
e-Load = Electronic Load
PSU1
Vo
LED
e-Load
Current Consumption
0
~0A
1.52-1.54V
ON
2
0.15-19A
1.52-1.54V
ON
5
0.38-0.47A
1.52-1.54V
ON
8
0.62-0.76A
1.52-1.54V
ON
8Æ15A
VoÆ0V
ON Æ OFF
Note:
The current consumption of PSU2 should be below 20mA for all tests.
4/24/2010
Comment
See scope waveform 1
See scope waveform 2
See scope waveform 3
See scope waveform 3
Over current protection test
Page 4 of 5
www.onsemi.com
Scope Waveform 1 – e-Load=0A
Scope Waveform 2 – e-Load=2A
Scope Waveform 3 – e-Load=5A, 8A
4/24/2010
Page 5 of 5
www.onsemi.com