NCP59152MNADGEVB_TEST_PROCEDURE.PDF - 50.0 KB

A
A
V
V
ELECTRONIC
LOAD
REGULATED DC
SUPPLY
Test Procedure for the NCP59152MNADGEVB Evaluation
Board
Figure 1: Test Setup
Test Procedure:
1. Connect the test setup as shown in Figure 1
2. Apply an input voltage, Vin = 3.5 V dc
3. Apply Iout = 10 mA load
4. Check that Vout is 2.5 V
5. Increase Iout load to 1.5 A
6. Check that Vout is 2.5 V
7. Check by Multimeter referenced to GND that Vflag is roughly 2.5 V
8. Decrease input voltage to Vin = 2.24V
9. Check that Vflag is less than 0.4 V
10. Power down the load
11. Power down Vinput
12. End of test
2/15/2012
-1-