NCP785AH120GEVB_TEST_PROCEDURE.pdf - 189 KB

Test Procedure for NCP785AH120GEVB
Test procedure:
1. Connect the test setup as shown Figure above
2. Appy an input AC voltage Vin = 85 Vac
4. Appy Iout = 0mA load.
5. Check that Vout is 12.0 V +/-5%.
6. Increase Iout up to 10 mA
7. Check that Vout is 12.0 V +/-5%.
7. Increase Vin up to 235 Vac and decrease the load in accordance with SOA
8. Power down the Load
9. Power down the Input Voltage
10. End of test
08/05/15
1
www.onsemi.com