NCV7691RCLV1GEVB_TEST_PROCEDURE.pdf - 213 KB

Test Procedure for the NCV7691RCLV1GEVB Evaluation Board
Initial setup
1.
2.
3.
Add jumpers OPEN1, OPEN2, … OPEN8
Remove jumpers SHORT1, SHORT2, … SHORT8
Connect strap S1, remove strap S2
Required Equipment
• Bench Power Supply with Ampermeter
• NCV7691 RCL Evaluation Board V2
Test procedure Step 1 (Current regulation):
1.
2.
3.
4.
5.
6.
Connect the setup as shown above;
Apply a supply voltage, sweep V BAT from 7 V to 40 V
Check LEDxxR or LEDxxW regulation
Check LED_ERR
Check I BAT .
Check FLTS (J1, pin4)
Table 1: Desired Results
LEDxxR or LEDxxW all on with constant brightness
LED_ERR = off
I BAT ~ 800 mA (Rx1 = 1R5) @ V BAT = 7 – 18 V;
I BAT ~ 400 mA (Rx1 = 1R5) @ V BAT = 21 – 28 V;
I BAT ~ 200 mA (Rx1 = 1R5) @ V BAT = 34 – 40 V
FLTS = LOW
Test procedure Step 2 (PWM):
1.
2.
3.
Apply a supply voltage, V BAT = 12 V
Toggle PWM (J1, pin 2) to GND
Check LEDxxR or LEDxxW states
Table 2: Desired Results
LEDxxR or LEDxxW off when PWM is shorted to GND
Test procedure Step 3 (LED Short):
07/20/15
1
www.onsemi.com
1.
2.
3.
4.
5.
6.
7.
8.
Apply a supply voltage, V BAT = 12 V
Short SHORT1 jumper terminals
Remove the short
Check LEDxxR or LEDxxW states
Check LED_ERR state
Check I BAT
Check FLTS (J1, pin4)
Disconnect V BAT
Table 2: Desired Results
LEDxxR or LEDxxW all off
LED_ERR = on
I BAT < 8 mA
FLTS = HIGH
Test procedure Step 4 (LED Open):
1.
2.
3.
4.
5.
6.
7.
8.
Apply a supply voltage, V BAT = 12 V
Open OPEN1 jumper terminal
Close the terminal again
Check LEDxxR or LEDxxW states
Check LED_ERR state
Check I BAT
Check FLTS (J1, pin 4)
Disconnect V BAT
Table 4: Desired Results
LEDxxR or LEDxxW all off
LED_ERR = on
I BAT < 8 mA
FLTS = HIGH
DC Characteristics
FLTS LOW
FLTS HIGH
MIN
0
4
TYP
MAX
1
6
End of Test
07/20/15
2
www.onsemi.com