NCV8871LVBGEVB_TEST_PROCEDURE.PDF - 43.0 KB

Test Procedure for the NCV8871LVBGEVB Evaluation Board
Equipment Needed
Power Supplies (1 High Power, 1-3 Logic Level)
Digital Volt Meter
Digital Ampere Meter
Function Generator (optional)
NCV8871LWB Test Procedure:
1) Apply 8 V to VIN. The output voltage should be around 7 V - 8 V.
2) Apply 5 V to the EN/SYNC pin. The output voltage should be around 10.6 V.
3) Attach a 10 Ω or 11 Ω load to the output. It should draw 1 A, and the output voltage
should be around 10.6 V.
4) Look at the switch node. The frequency should be around 170 kHz.
5) Apply a 200 kHz, 5 Vpp clock to the EN/SYNC pin. The output voltage should be around
10.6 V.
Look at the switch node. The frequency should be 200 kHz.
11/16/2012
-1-
www.onsemi.com