NCV8873LEDBSTGEVB_TEST_PROCEDURE.PDF - 326.0 KB

Test Procedure for the NCV8873LEDBSTGEVB Evaluation Board
Operational Guidelines
1. Connect a DC input voltage, within the 6 V to 40 V range, between VIN and
GND.
2. Connect a DC enable voltage, within the 2.0 V to 5.0 V range, between
EN/SYNC and GND.
3. Connect a function generator between PWM and GND. It is recommended the
waveform be set to
a. 125-200 Hz square typical frequency range,
b. low state voltage of 0 – 0.8V
c. high state of 1.8-5V range
d. duty cycle from 0.1% to 100%
4. Overvoltage may be tested by enabling the board (EN/SYNC) with jumper J1
removed.
5. Optionally,
a. for external clock synchronization, connect a pulse source between
EN/SYNC and GND. The high state level should be within the 1.8 to 5 V
range*, and the low state level within the -0.3 V to 0.8 V range, with a
minimum pulse width of 40 ns and a frequency within the 1 MHz and 1.1
MHz range.
b. Jumper J1 should be removed if an external load is to be used instead of
on-board LEDs. Input voltage operating range is valid for loads requiring
Vout < 40 V.
Optional
load (must
remove J1)
Vin
Venable
PWM
Dimming
Figure 1. Demo Board Connections
5/07/2013
1
www.onsemi.com
Typical Performance
Start-up
VOUT
EN
Figure 2 Typical start-up with VIN = 12 V, 10 LEDs/60mA
5/07/2013
2