MEANWELL GS220_11

GS220
220W AC-DC Single Output Desktop
series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.91
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
Class power ( with earth pin)
LED indicator for power on
No load power consumption<0.5W
Meet EISA 2007(Energy Independence and Security Act)
2 years warranty
(except for 48V)
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
GS220A24-R7B
GS220A48-R7B
GS220A12
GS220A15
15V
GS220A20
20V
GS220A24
24V
GS220A48
48V
15A
13.4A
11A
9.2A
4.6A
0 ~ 15A
0 ~ 13.4A
0 ~ 11A
0 ~ 9.2A
0 ~ 4.6A
RATED POWER (max.)
180W
201W
220W
221W
221W
100mVp-p
150mVp-p
180mVp-p
240mVp-p
RIPPLE & NOISE (max.) Note.3 80mVp-p
VOLTAGE TOLERANCE Note.4
5.0%
5.0%
4.0%
3.0%
2.0%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
4.0%
3.0%
2.0%
93.5%
94.5%
Note.5
SETUP, RISE TIME
Note.7 2000ms, 20ms / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.8 90 ~ 264VAC
20ms / 230VAC
2000ms, 20ms / 115VAC at full load
20ms / 115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.91 / 230VAC
EFFICIENCY (Typ.)
90%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
4A / 115VAC
PROTECTION OVER VOLTAGE
PF>0.98 / 115VAC at full load
90%
92%
2A / 230VAC
120A / 230VAC
1.5mA / 240VAC
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
95
5 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +60 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 6)
EMC EMISSION
EMC IMMUNITY
NOTE
GS220A20-R7B
CURRENT RANGE
OVERLOAD
CONNECTOR
GS220A15-R7B
RATED CURRENT
LEAKAGE CURRENT(max.)
OTHERS
geprUfre
Sicherheit
GS220A12-R7B
Note.2 12V
LOAD REGULATION
INPUT
TUV
Rheinland
Product Safety
-40 ~ +85
, 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 class B / CISPR22 class B, CNS13438 class B, GB9254 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
PACKING
PLUG
191.3Khrs min. MIL-HDBK-217F(25 )
210*85*46mm (L*W*H)
1.1Kg; 12pcs/14.2Kg/0.73CUFT
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
MTBF
DIMENSION
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:GS220-SPEC 2011-06-15
GS220
220W AC-DC Single Output Desktop
Mechanical Specification
Case No.961A
46
series
Unit:mm
210
UL1185 16AWGx4C 1000 50mm
30 3mm
POWER LED
85
23
14
Plug Assignment
Standard plug: R7B
R7B
PIN NO. OUTPUT
2
1
3
4
1,4
+V
2,3
-V
AC FG
-V connected to AC FG
Derating Curve
Static Characteristics
100
230VAC
100
90
For others
80
80
For 12~15V
70
100VAC for others
110VAC for 12~15V
50
LOAD (%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GS220-SPEC 2011-06-15