ELDRS_50K_Report_RH1014MW_Fab_Lot_W1213460_1_W1.pdf

ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Products contained in this shipment may be subject to ITAR
regulations.
Warning:
The export of these commodity(ies), technology, or software are subject either to the
U.S. Commerce Department Export Administration Regulations (E.A.R.), or to the U.S.
State Department International Traffic In Arms Regulations (I.T.A.R.). Diversion, the
shipment to unauthorized locations or entities, or the disclosure of related technical data
or software to unauthorized foreign nationals is contrary to U.S. law and is prohibited. If
export is authorized to a specific country or end-users, compliance with the U.S. export
laws is required prior to transfer, transshipment on a non-continuous voyage, or disposal
in any other country, or to any other end-user of these commodities, either in their
original form or after being incorporated into other end-items.
An ISO 9001:2008 and DSCC Certified Company
1
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Enhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the
RH1014MW Quad Precision Operational Amplifier for Linear Technology
Customer: Linear Technology, PO# 7084J
RAD Job Number: 12-900
Part Type Tested: RH1014MW Quad Precision Operational Amplifier, RH1014M Quad Precision
Operational Amplifier Datasheet Revision G
Traceability Information: Assembly Lot Number: 676643, Fab Lot Number: W1213460.1, Wafer
Number: 1, Date Code: 1231A. See photograph of unit under test in Appendix A.
Quantity of Units: 11 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 1
unit for control. Serial numbers 59, 149, 233, 310 and 393 were biased during irradiation, serial numbers
443, 516, 574, 589 and 732 were unbiased during irradiation and serial number 829 was used as control.
See Appendix B for the radiation bias connection table.
Radiation and Electrical Test Increments: 10mrad(Si)/s ionizing radiation with electrical test
increments: pre-irradiation, 10krad(Si), 20krad(Si), 30krad(Si) and 50krad(Si).
Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD
Overtest and Post-Irradiation Anneal: No overtest. 24-hour room temperature anneal followed by a
168-hour 100°C anneal. Both anneals were performed in the same electrical bias condition as the
irradiations. Electrical measurements were made following each anneal increment.
Radiation Test Standard: MIL-STD-750E TM1019 and/or MIL-STD-883H TM1019 Condition D and
Linear Technology RH1014M Quad Precision Operational Amplifier Datasheet Revision G.
Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS03, Calibration Date:
4/26/2012, Calibration Due: 4/26/2013. LTS2101 Family Board, Entity ID FB10. LTS0600 Test Fixture,
Entity ID TF03. BGSS-970312 RH1014 DUT Board. Test Program: RH1014.SR5
Facility and Radiation Source: Aeroflex RAD's Longmire Laboratories, Colorado Springs, CO.
Gamma rays provided by Co60 (GB-150) low dose rate source. Dosimetry performed by Air Ionization
Chamber (AIC) traceable to NIST. Aeroflex RAD's dosimetry has been audited by DSCC and Aeroflex
RAD has been awarded Laboratory Suitability for MIL-STD-750 and MIL-STD-883 TM 1019.
Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and
MIL-STD-750.
Test Result: PASSED the enhanced low dose rate sensitivity test to the
maximum tested dose level of 50krad(Si) with all parameters remaining within
their datasheet specifications.
An ISO 9001:2008 and DSCC Certified Company
2
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
1.0. Overview and Background
It is well known that total dose ionizing radiation can cause parametric degradation and ultimately
functional failure in electronic devices. The damage occurs via electron-hole pair production, transport
and trapping in the dielectric regions. In advanced CMOS technology nodes (0.6µm and smaller) the
bulk of the damage is manifested in the thicker isolation regions, such as shallow trench or local
oxidation of silicon (LOCOS) oxides (also known as "birds-beak" oxides). However, many linear and
mixed signal devices that utilize bipolar minority carrier elements exhibit an enhanced low dose rate
sensitivity (ELDRS). At this time there is no known or accepted a priori method for predicting
susceptibility to ELDRS or simulating the low dose rate sensitivity with a "conventional" room
temperature 50-300rad(Si)/s irradiation (Condition A in MIL-STD-883 TM 1019.8). Over the past 10
years a number of accelerating techniques have been examined, including an elevated temperature
anneal, such as that used for MOS devices (see ASTM-F-1892 for more technical details) and irradiating
at various temperatures. However, none of these techniques have proven useful across the wide variety
of linear and/or mixed signal devices used in spaceborne applications.
The latest requirement incorporated in MIL-STD-883 TM 1019 requires that devices that could
potentially exhibit ELDRS "shall be tested either at the intended application dose rate, at a prescribed
low dose rate to an overtest radiation level, or with an accelerated test such as an elevated temperature
irradiation test that includes a parameter delta design margin". While the recently released MIL-STD883 TM 1019 allows for accelerated testing, the requirements for this are to essentially perform a low
dose rate ELDRS test to verify the suitability of the acceleration method on the component of interest
before the acceleration technique can be instituted. Based on the limitations of accelerated testing and to
meet the requirements of MIL-STD-883 TM1019.8 Condition D, we have performed a low dose rate test
at 10mrad(Si)/s.
2.0. Radiation Test Apparatus
The low dose rate testing described in this final report was performed using the facilities at Aeroflex
RAD's Longmire Laboratories in Colorado Springs, CO. The low dose rate source is a GB-150 irradiator
modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily
shielded by lead. During the irradiation exposures the rod is raised by an electronic timer/controller and
the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from
approximately 1mrad(Si)/s to a maximum of approximately 50rad(Si)/s, determined by the distance
from the source. For low dose rate testing described in this report, the devices are placed approximately
2-meters from the Co-60 rods. The irradiator calibration is maintained by Aeroflex RAD's Longmire
Laboratories using air ionization chamber (AIC) dosimetry traceable to the National Institute of
Standards and Technology (NIST). Figure 2.1 shows a photograph of the GB-150 Co-60 irradiator at
Aeroflex RAD's Longmire Laboratory facility.
An ISO 9001:2008 and DSCC Certified Company
3
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Figure 2.1. Aeroflex RAD's Co-60 irradiator. The dose rate is obtained by positioning the device-under-test at a
fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately 50rad(Si)/s close
to the rods down to <1mrad(Si)/s at a distance of approximately 4-meters.
An ISO 9001:2008 and DSCC Certified Company
4
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
3.0. Radiation Test Conditions
The RH1014MW Quad Precision Operational Amplifier described in this final report were irradiated
using a split 15V supply and with all pins tied to ground, that is biased and unbiased. See Appendix B
for details on the biasing conditions during radiation exposure. In our opinion, this bias circuit satisfies
the requirements of MIL-STD-883H TM1019.8 Section 3.9.3 Bias and Loading Conditions which states
"The bias applied to the test devices shall be selected to produce the greatest radiation induced damage
or the worst-case damage for the intended application, if known. While maximum voltage is often worst
case some bipolar linear device parameters (e.g. input bias current or maximum output load current)
exhibit more degradation with 0 V bias."
The devices were irradiated to a maximum total ionizing dose level of 50krad(Si) with incremental
readings at 10krad(Si), 20krad(Si) and 30krad(Si). Electrical testing occurred within one hour following
the end of each irradiation segment. For intermediate irradiations, the units were tested and returned to
total dose exposure within two hours from the end of the previous radiation increment. The radiation
exposure bias board was positioned in the Co-60 cell to provide the targeted dose rate of 10mrad(Si)/s
and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019.8 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test
specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm
Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and
for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1)
initially, (2) when the source is changed, or (3) when the orientation or configuration of the source,
container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g.,
a TLD) in the device-irradiation container at the approximate test-device position. If it can be
demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors
due to dose enhancement, the Pb/Al container may be omitted".
The final dose rate within the lead-aluminum box was determined based on air ionization chamber
(AIC) dosimetry measurements just prior to the beginning of the total dose irradiations. The final dose
rate for this work was 10mrad(Si)/s with a precision of ±5%.
An ISO 9001:2008 and DSCC Certified Company
5
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
4.0. Tested Parameters
During the enhanced low dose rate sensitivity testing the following electrical parameters were measured
pre- and post-irradiation:
1. Positive Supply Current 15V (A) @ VS= +/-15V, VCM= 0V
2. Negative Supply Current 15V (A) @ VS= +/-15V, VCM= 0V
3. Offset Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V
4. Offset Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V
5. Offset Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V
6. Offset Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V
7. Offset Current 15V 1 (A) @ VS= +/-15V, VCM= 0V
8. Offset Current 15V 2 (A) @ VS= +/-15V, VCM= 0V
9. Offset Current 15V 3 (A) @ VS= +/-15V, VCM= 0V
10. Offset Current 15V 4 (A) @ VS= +/-15V, VCM= 0V
11. Positive Bias Current 15V 1 (A) @ VS= +/-15V, VCM= 0V
12. Positive Bias Current 15V 2 (A) @ VS= +/-15V, VCM= 0V
13. Positive Bias Current 15V 3 (A) @ VS= +/-15V, VCM= 0V
14. Positive Bias Current 15V 4 (A) @ VS= +/-15V, VCM= 0V
15. Negative Bias Current 15V 1 (A) @ VS= +/-15V, VCM= 0V
16. Negative Bias Current 15V 2 (A) @ VS= +/-15V, VCM= 0V
17. Negative Bias Current 15V 3 (A) @ VS= +/-15V, VCM= 0V
18. Negative Bias Current 15V 4 (A) @ VS= +/-15V, VCM= 0V
19. Common Mode Rejection Ratio 1 (dB) @ VS= +/-15V, VCM= 13V, -15V
20. Common Mode Rejection Ratio 2 (dB) @ VS= +/-15V, VCM= 13V, -15V
21. Common Mode Rejection Ratio 3 (dB) @ VS= +/-15V, VCM= 13V, -15V
22. Common Mode Rejection Ratio 4 (dB) @ VS= +/-15V, VCM= 13V, -15V
23. Power Supply Rejection Ratio 1 (dB) @ VS= +/-10V to +/-18V, VCM= 0V
24. Power Supply Rejection Ratio 2 (dB) @ VS= +/-10V to +/-18V, VCM= 0V
25. Power Supply Rejection Ratio 3 (dB) @ VS= +/-10V to +/-18V, VCM= 0V
26. Power Supply Rejection Ratio 4 (dB) @ VS= +/-10V to +/-18V, VCM= 0V
27. Open Loop Gain 1 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
28. Open Loop Gain 2 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
29. Open Loop Gain 3 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
30. Open Loop Gain 4 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
31. Positive Output Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
32. Positive Output Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
33. Positive Output Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
34. Positive Output Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
35. Negative Output Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
36. Negative Output Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
37. Negative Output Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
An ISO 9001:2008 and DSCC Certified Company
6
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
38. Negative Output Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
39. Positive Slew Rate 1 (V/us) @ VS= +/-15V
40. Positive Slew Rate 2 (V/us) @ VS= +/-15V
41. Positive Slew Rate 3 (V/us) @ VS= +/-15V
42. Positive Slew Rate 4 (V/us) @ VS= +/-15V
43. Negative Slew Rate 1 (V/us) @ VS= +/-15V
44. Negative Slew Rate 2 (V/us) @ VS= +/-15V
45. Negative Slew Rate 3 (V/us) @ VS= +/-15V
46. Negative Slew Rate 4 (V/us) @ VS= +/-15V
47. Positive Supply Current 5V (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
48. Negative Supply Current 5V (A) @ VS= +5V , VCM= 0V, VOUT= 1.4V
49. Offset Voltage 5V 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V
50. Offset Voltage 5V 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V
51. Offset Voltage 5V 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V
52. Offset Voltage 5V 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V
53. Offset Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
54. Offset Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
55. Offset Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
56. Offset Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
57. Positive Bias Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
58. Positive Bias Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
59. Positive Bias Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
60. Positive Bias Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
61. Negative Bias Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
62. Negative Bias Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
63. Negative Bias Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
64. Negative Bias Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
65. Positive Output Voltage 5V OPEN 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
66. Positive Output Voltage 5V OPEN 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
67. Positive Output Voltage 5V OPEN 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
68. Positive Output Voltage 5V OPEN 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
69. Positive Output Voltage 5V 600 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
70. Positive Output Voltage 5V 600 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
71. Positive Output Voltage 5V 600 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
72. Positive Output Voltage 5V 600 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
73. Output Voltage Low 5V OPEN 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
74. Output Voltage Low 5V OPEN 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
75. Output Voltage Low 5V OPEN 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
76. Output Voltage Low 5V OPEN 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
77. Output Voltage Low 5V 600 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
78. Output Voltage Low 5V 600 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
79. Output Voltage Low 5V 600 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
An ISO 9001:2008 and DSCC Certified Company
7
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
80. Output Voltage Low 5V 600 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
81. Output Voltage Low 5V 1mA 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
82. Output Voltage Low 5V 1mA 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
83. Output Voltage Low 5V 1mA 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
84. Output Voltage Low 5V 1mA 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
Appendix C details the measured parameters, test conditions, pre-irradiation specification and
measurement resolution for each of the measurements.
The parametric data was obtained as "read and record" and all the raw data plus an attributes summary
are contained in this report as well as in a separate Excel file. The attributes data contains the average,
standard deviation and the average with the KTL values applied. The KTL value used in this work is
2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The
90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535
sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the
following criteria must be met for a device to pass the low dose rate test: following the radiation
exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units
irradiated without electrical bias and the KTL statistics are included in this report for reference only. If
any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet
specification limits, then the lot could be logged as a failure.
An ISO 9001:2008 and DSCC Certified Company
8
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
5.0. ELDRS Test Results
Based on this criterion the RH1014MW Quad Precision Operational Amplifier (from the lot traceability
information provided on the first page of this test report) PASSED the enhanced low dose rate
sensitivity test to the maximum tested dose level of 50krad(Si) with all parameters remaining within
their datasheet specifications.
Figures 5.1 through 5.84 show plots of all the measured parameters versus total ionizing dose while
Tables 5.1 - 5.84 show the corresponding raw data for each of these parameters. In the data plots the
solid diamonds are the average of the measured data points for the sample irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the units irradiated with all
pins tied to ground. The black lines (solid or dashed) are the average of the data points after application
of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or
dashed) are the average of the data points after application of the KTL statistics on the sample irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or
maximum specification value as defined in the datasheet and/or test plan.
In addition to the radiation test results, the data plots and tables described above contain anneal data.
The anneals are performed to better understand the underlying physical mechanisms responsible for
radiation-induced parametric shifts and are not part of the criteria used to establish whether or not the lot
passes or fails the low dose rate test. In all cases the parts either improved or exhibited no change during
the anneal.
The control units, as expected, show no significant changes to any of the parameters. Therefore we can
conclude that the electrical testing remained in control throughout the duration of the tests and the
observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section
to facilitate the location of a particular parameter.
An ISO 9001:2008 and DSCC Certified Company
9
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Positive Supply Current 15V (A)
@ VS= +/-15V, VCM= 0V
2.50E-03
2.00E-03
1.50E-03
1.00E-03
5.00E-04
0.00E+00
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.1. Plot of Positive Supply Current 15V (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
10
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.1. Raw data for Positive Supply Current 15V (A) @ VS= +/-15V, VCM= 0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Positive Supply Current 15V (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +/-15V, VCM= 0V
Device
0
10
20
30
50
60
70
59 1.46E-03 1.42E-03 1.42E-03 1.39E-03 1.31E-03 1.32E-03 1.28E-03
149 1.50E-03 1.44E-03 1.43E-03 1.41E-03 1.32E-03 1.32E-03 1.29E-03
233 1.53E-03 1.47E-03 1.47E-03 1.45E-03 1.36E-03 1.37E-03 1.33E-03
310 1.46E-03 1.43E-03 1.42E-03 1.40E-03 1.31E-03 1.32E-03 1.29E-03
393 1.51E-03 1.46E-03 1.46E-03 1.43E-03 1.34E-03 1.34E-03 1.32E-03
443 1.49E-03 1.50E-03 1.49E-03 1.46E-03 1.41E-03 1.41E-03 1.40E-03
516 1.46E-03 1.51E-03 1.48E-03 1.46E-03 1.41E-03 1.41E-03 1.40E-03
574 1.45E-03 1.50E-03 1.48E-03 1.46E-03 1.41E-03 1.41E-03 1.40E-03
589 1.44E-03 1.47E-03 1.45E-03 1.43E-03 1.38E-03 1.37E-03 1.37E-03
732 1.46E-03 1.49E-03 1.47E-03 1.44E-03 1.39E-03 1.39E-03 1.39E-03
829 1.47E-03 1.46E-03 1.46E-03 1.46E-03 1.46E-03 1.46E-03 1.46E-03
Biased Statistics
Average Biased
1.49E-03 1.44E-03 1.44E-03 1.42E-03 1.33E-03 1.33E-03 1.30E-03
Std Dev Biased
3.42E-05 2.18E-05 2.35E-05 2.36E-05 2.30E-05 2.09E-05 2.05E-05
Ps90%/90% (+KTL) Biased
1.59E-03 1.50E-03 1.51E-03 1.48E-03 1.39E-03 1.39E-03 1.36E-03
Ps90%/90% (-KTL) Biased
1.40E-03 1.38E-03 1.38E-03 1.35E-03 1.26E-03 1.28E-03 1.25E-03
Un-Biased Statistics
Average Un-Biased
1.46E-03 1.49E-03 1.47E-03 1.45E-03 1.40E-03 1.40E-03 1.39E-03
Std Dev Un-Biased
1.82E-05 1.69E-05 1.65E-05 1.51E-05 1.50E-05 1.49E-05 1.28E-05
Ps90%/90% (+KTL) Un-Biased
1.51E-03 1.54E-03 1.52E-03 1.49E-03 1.44E-03 1.44E-03 1.43E-03
Ps90%/90% (-KTL) Un-Biased
1.41E-03 1.45E-03 1.43E-03 1.41E-03 1.36E-03 1.36E-03 1.36E-03
Specification MAX
2.20E-03 2.20E-03 2.20E-03 2.20E-03 2.20E-03 2.20E-03 2.20E-03
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
11
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Negative Supply Current 15V (A)
@ VS= +/-15V, VCM= 0V
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
-2.00E-03
-2.50E-03
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.2. Plot of Negative Supply Current 15V (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
12
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.2. Raw data for Negative Supply Current 15V (A) @ VS= +/-15V, VCM= 0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Supply Current 15V (A)
@ VS= +/-15V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
-1.46E-03
-1.50E-03
-1.53E-03
-1.46E-03
-1.51E-03
-1.49E-03
-1.46E-03
-1.45E-03
-1.44E-03
-1.46E-03
-1.47E-03
Total
10
-1.42E-03
-1.44E-03
-1.47E-03
-1.43E-03
-1.47E-03
-1.51E-03
-1.51E-03
-1.50E-03
-1.47E-03
-1.49E-03
-1.46E-03
Dose (krad(Si))
20
30
-1.42E-03 -1.39E-03
-1.44E-03 -1.42E-03
-1.48E-03 -1.45E-03
-1.43E-03 -1.40E-03
-1.46E-03 -1.43E-03
-1.49E-03 -1.46E-03
-1.48E-03 -1.46E-03
-1.48E-03 -1.46E-03
-1.45E-03 -1.43E-03
-1.47E-03 -1.44E-03
-1.46E-03 -1.46E-03
50
-1.31E-03
-1.32E-03
-1.36E-03
-1.32E-03
-1.34E-03
-1.41E-03
-1.41E-03
-1.41E-03
-1.37E-03
-1.39E-03
-1.46E-03
24 Hr
Anneal
60
-1.32E-03
-1.32E-03
-1.37E-03
-1.32E-03
-1.34E-03
-1.41E-03
-1.41E-03
-1.41E-03
-1.38E-03
-1.39E-03
-1.46E-03
168 Hr
Anneal
70
-1.28E-03
-1.29E-03
-1.33E-03
-1.28E-03
-1.32E-03
-1.40E-03
-1.40E-03
-1.40E-03
-1.38E-03
-1.39E-03
-1.46E-03
-1.49E-03 -1.45E-03 -1.44E-03 -1.42E-03 -1.33E-03 -1.33E-03 -1.30E-03
3.42E-05 2.26E-05 2.34E-05 2.44E-05 2.26E-05 2.08E-05 2.07E-05
-1.40E-03 -1.38E-03 -1.38E-03 -1.35E-03 -1.27E-03 -1.28E-03 -1.24E-03
-1.59E-03 -1.51E-03 -1.51E-03 -1.49E-03 -1.39E-03 -1.39E-03 -1.36E-03
-1.46E-03
1.80E-05
-1.41E-03
-1.51E-03
-2.20E-03
PASS
-1.50E-03
1.66E-05
-1.45E-03
-1.54E-03
-2.20E-03
PASS
-1.47E-03
1.61E-05
-1.43E-03
-1.52E-03
-2.20E-03
PASS
-1.45E-03
1.50E-05
-1.41E-03
-1.49E-03
-2.20E-03
PASS
-1.40E-03
1.48E-05
-1.36E-03
-1.44E-03
-2.20E-03
PASS
An ISO 9001:2008 and DSCC Certified Company
13
-1.40E-03
1.52E-05
-1.36E-03
-1.44E-03
-2.20E-03
PASS
-1.39E-03
1.23E-05
-1.36E-03
-1.43E-03
-2.20E-03
PASS
Offset Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.3. Plot of Offset Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V versus total dose. The solid diamonds
are the average of the measured data points for the samples irradiated under electrical bias while the shaded
diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The
black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the
samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted
line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the
datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
14
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.3. Raw data for Offset Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Offset Voltage 15V 1 (V)
@ VS= +/-15V, VCM= 0V
Device
0
59 -2.71E-05
149 2.05E-05
233 3.19E-05
310 6.09E-05
393 2.95E-05
443 3.51E-05
516 7.30E-06
574 3.41E-05
589 1.50E-05
732 8.45E-05
829 1.11E-04
Biased Statistics
Average Biased
2.31E-05
Std Dev Biased
3.19E-05
Ps90%/90% (+KTL) Biased
1.11E-04
Ps90%/90% (-KTL) Biased
-6.44E-05
Un-Biased Statistics
Average Un-Biased
3.52E-05
Std Dev Un-Biased
3.01E-05
Ps90%/90% (+KTL) Un-Biased
1.18E-04
Ps90%/90% (-KTL) Un-Biased
-4.73E-05
Specification MIN
-3.00E-04
Status
PASS
Specification MAX
3.00E-04
Status
PASS
Dose (krad(Si))
20
30
1.44E-05 3.45E-05
4.77E-05 6.50E-05
7.67E-05 9.75E-05
1.08E-04 1.27E-04
6.61E-05 7.88E-05
5.63E-05 7.20E-05
3.35E-05 4.36E-05
6.66E-05 8.18E-05
5.69E-05 7.22E-05
1.31E-04 1.49E-04
1.13E-04 1.11E-04
50
6.46E-05
9.72E-05
1.34E-04
1.63E-04
1.09E-04
1.03E-04
7.21E-05
1.09E-04
1.13E-04
1.98E-04
1.13E-04
24 Hr
Anneal
60
6.35E-05
9.64E-05
1.33E-04
1.62E-04
1.09E-04
1.03E-04
7.39E-05
1.12E-04
1.15E-04
2.01E-04
1.11E-04
4.52E-05 6.25E-05 8.04E-05
3.35E-05 3.46E-05 3.45E-05
1.37E-04 1.57E-04 1.75E-04
-4.67E-05 -3.23E-05 -1.43E-05
1.13E-04
3.70E-05
2.15E-04
1.18E-05
1.13E-04 6.96E-05
3.73E-05 3.60E-05
2.15E-04 1.68E-04
1.06E-05 -2.91E-05
Total
10
-2.12E-06
2.84E-05
6.16E-05
8.59E-05
5.23E-05
5.07E-05
2.02E-05
4.99E-05
3.69E-05
1.08E-04
1.13E-04
5.31E-05
3.30E-05
1.43E-04
-3.73E-05
-4.50E-04
PASS
4.50E-04
PASS
6.88E-05
3.66E-05
1.69E-04
-3.16E-05
-4.50E-04
PASS
4.50E-04
PASS
8.36E-05
3.90E-05
1.91E-04
-2.33E-05
-4.50E-04
PASS
4.50E-04
PASS
1.19E-04
4.71E-05
2.48E-04
-1.02E-05
-6.00E-04
PASS
6.00E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
15
1.21E-04
4.77E-05
2.52E-04
-9.93E-06
-6.00E-04
PASS
6.00E-04
PASS
168 Hr
Anneal
70
2.06E-05
4.52E-05
9.35E-05
1.08E-04
8.02E-05
6.52E-05
3.97E-05
6.20E-05
5.24E-05
1.33E-04
1.12E-04
7.05E-05
3.65E-05
1.71E-04
-2.95E-05
-6.00E-04
PASS
6.00E-04
PASS
Offset Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.4. Plot of Offset Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V versus total dose. The solid diamonds
are the average of the measured data points for the samples irradiated under electrical bias while the shaded
diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The
black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the
samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted
line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the
datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
16
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.4. Raw data for Offset Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Offset Voltage 15V 2 (V)
@ VS= +/-15V, VCM= 0V
Device
0
59 -1.97E-05
149 -7.91E-06
233 1.87E-06
310 9.81E-05
393 3.72E-05
443 -3.30E-05
516 2.17E-05
574 4.34E-05
589 2.69E-05
732 8.36E-05
829 5.70E-05
Biased Statistics
Average Biased
2.19E-05
Std Dev Biased
4.76E-05
Ps90%/90% (+KTL) Biased
1.52E-04
Ps90%/90% (-KTL) Biased
-1.09E-04
Un-Biased Statistics
Average Un-Biased
2.85E-05
Std Dev Un-Biased
4.21E-05
Ps90%/90% (+KTL) Un-Biased
1.44E-04
Ps90%/90% (-KTL) Un-Biased
-8.69E-05
Specification MIN
-3.00E-04
Status
PASS
Specification MAX
3.00E-04
Status
PASS
Total
10
1.13E-05
9.83E-06
3.04E-05
1.24E-04
6.62E-05
-2.12E-05
4.34E-05
6.00E-05
4.95E-05
1.09E-04
5.61E-05
Dose (krad(Si))
20
30
2.84E-05 4.39E-05
2.37E-05 3.34E-05
4.35E-05 5.70E-05
1.40E-04 1.60E-04
8.06E-05 9.43E-05
-1.49E-05 -4.65E-06
5.99E-05 7.55E-05
7.27E-05 8.37E-05
6.95E-05 8.38E-05
1.26E-04 1.45E-04
5.62E-05 5.44E-05
50
8.06E-05
6.03E-05
9.37E-05
2.08E-04
1.28E-04
1.74E-05
1.15E-04
1.15E-04
1.29E-04
1.80E-04
5.52E-05
24 Hr
168 Hr
Anneal
Anneal
60
70
7.73E-05 4.04E-05
6.02E-05 2.42E-05
9.14E-05 5.03E-05
2.06E-04 1.52E-04
1.26E-04 9.37E-05
1.67E-05 -1.23E-05
1.13E-04 6.11E-05
1.10E-04 6.78E-05
1.29E-04 7.25E-05
1.81E-04 1.39E-04
5.57E-05 5.52E-05
4.84E-05 6.32E-05 7.77E-05 1.14E-04 1.12E-04 7.22E-05
4.82E-05 4.82E-05 5.13E-05 5.78E-05 5.79E-05 5.17E-05
1.80E-04 1.95E-04 2.18E-04 2.73E-04 2.71E-04 2.14E-04
-8.37E-05 -6.91E-05 -6.31E-05 -4.45E-05 -4.65E-05 -6.97E-05
4.81E-05
4.65E-05
1.76E-04
-7.93E-05
-4.50E-04
PASS
4.50E-04
PASS
6.26E-05
5.04E-05
2.01E-04
-7.56E-05
-4.50E-04
PASS
4.50E-04
PASS
7.66E-05
5.32E-05
2.22E-04
-6.93E-05
-4.50E-04
PASS
4.50E-04
PASS
1.11E-04
5.90E-05
2.73E-04
-5.05E-05
-6.00E-04
PASS
6.00E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
17
1.10E-04
5.94E-05
2.73E-04
-5.29E-05
-6.00E-04
PASS
6.00E-04
PASS
6.57E-05
5.38E-05
2.13E-04
-8.18E-05
-6.00E-04
PASS
6.00E-04
PASS
Offset Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.5. Plot of Offset Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V versus total dose. The solid diamonds
are the average of the measured data points for the samples irradiated under electrical bias while the shaded
diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The
black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the
samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted
line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the
datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
18
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.5. Raw data for Offset Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Offset Voltage 15V 3 (V)
@ VS= +/-15V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
0
-4.11E-05
6.16E-05
2.06E-05
-2.11E-05
6.38E-05
-2.79E-05
1.99E-05
9.01E-05
-1.51E-06
-3.56E-06
1.04E-04
Biased Statistics
Average Biased
1.68E-05
Std Dev Biased
4.75E-05
Ps90%/90% (+KTL) Biased
1.47E-04
Ps90%/90% (-KTL) Biased
-1.13E-04
Un-Biased Statistics
Average Un-Biased
1.54E-05
Std Dev Un-Biased
4.51E-05
Ps90%/90% (+KTL) Un-Biased
1.39E-04
Ps90%/90% (-KTL) Un-Biased
-1.08E-04
Specification MIN
-3.00E-04
Status
PASS
Specification MAX
3.00E-04
Status
PASS
Dose (krad(Si))
20
30
1.45E-05 2.95E-05
9.14E-05 1.09E-04
6.41E-05 7.71E-05
2.90E-05 4.63E-05
1.16E-04 1.27E-04
3.31E-06 1.42E-05
6.48E-05 7.84E-05
1.25E-04 1.40E-04
4.29E-05 5.90E-05
3.51E-05 5.26E-05
1.03E-04 1.02E-04
50
7.24E-05
1.36E-04
1.09E-04
9.14E-05
1.67E-04
4.09E-05
1.15E-04
1.73E-04
1.01E-04
9.66E-05
1.03E-04
24 Hr
Anneal
60
6.87E-05
1.37E-04
1.07E-04
8.94E-05
1.66E-04
3.88E-05
1.14E-04
1.73E-04
9.98E-05
9.53E-05
1.04E-04
4.59E-05 6.30E-05 7.77E-05
4.47E-05 4.22E-05 4.09E-05
1.69E-04 1.79E-04 1.90E-04
-7.67E-05 -5.26E-05 -3.46E-05
1.15E-04
3.73E-05
2.17E-04
1.30E-05
1.14E-04 7.72E-05
3.85E-05 3.88E-05
2.19E-04 1.84E-04
8.04E-06 -2.91E-05
Total
10
-4.89E-06
7.86E-05
4.70E-05
8.50E-06
1.00E-04
-7.43E-06
4.51E-05
1.13E-04
2.44E-05
1.96E-05
1.04E-04
3.90E-05
4.55E-05
1.64E-04
-8.58E-05
-4.50E-04
PASS
4.50E-04
PASS
5.41E-05
4.51E-05
1.78E-04
-6.97E-05
-4.50E-04
PASS
4.50E-04
PASS
6.88E-05
4.61E-05
1.95E-04
-5.76E-05
-4.50E-04
PASS
4.50E-04
PASS
1.05E-04
4.72E-05
2.35E-04
-2.41E-05
-6.00E-04
PASS
6.00E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
19
1.04E-04
4.80E-05
2.36E-04
-2.75E-05
-6.00E-04
PASS
6.00E-04
PASS
168 Hr
Anneal
70
4.58E-05
1.12E-04
6.42E-05
3.97E-05
1.24E-04
1.41E-05
5.88E-05
1.22E-04
4.68E-05
3.90E-05
1.03E-04
5.62E-05
4.05E-05
1.67E-04
-5.48E-05
-6.00E-04
PASS
6.00E-04
PASS
Offset Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.6. Plot of Offset Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V versus total dose. The solid diamonds
are the average of the measured data points for the samples irradiated under electrical bias while the shaded
diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The
black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the
samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted
line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the
datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
20
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.6. Raw data for Offset Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Offset Voltage 15V 4 (V)
@ VS= +/-15V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
0
3.94E-05
-3.10E-07
-7.88E-05
6.51E-05
-6.62E-05
5.05E-05
1.26E-06
-1.88E-06
3.29E-05
1.55E-04
6.10E-05
Biased Statistics
Average Biased
-8.15E-06
Std Dev Biased
6.33E-05
Ps90%/90% (+KTL) Biased
1.66E-04
Ps90%/90% (-KTL) Biased
-1.82E-04
Un-Biased Statistics
Average Un-Biased
4.76E-05
Std Dev Un-Biased
6.41E-05
Ps90%/90% (+KTL) Un-Biased
2.23E-04
Ps90%/90% (-KTL) Un-Biased
-1.28E-04
Specification MIN
-3.00E-04
Status
PASS
Specification MAX
3.00E-04
Status
PASS
Total
10
6.75E-05
2.85E-05
-4.40E-05
9.84E-05
-4.20E-05
7.08E-05
1.32E-05
6.45E-06
5.51E-05
1.77E-04
6.08E-05
Dose (krad(Si))
20
30
8.16E-05 9.41E-05
4.09E-05 5.29E-05
-2.82E-05 -1.09E-05
1.14E-04 1.30E-04
-3.10E-05 -2.26E-05
8.13E-05 9.36E-05
2.62E-05 3.77E-05
1.65E-05 3.04E-05
7.54E-05 9.41E-05
1.97E-04 2.16E-04
6.00E-05 5.87E-05
50
1.28E-04
8.19E-05
2.71E-05
1.69E-04
5.97E-06
1.22E-04
6.45E-05
5.53E-05
1.34E-04
2.64E-04
6.02E-05
24 Hr
168 Hr
Anneal
Anneal
60
70
1.27E-04 9.52E-05
8.09E-05 6.27E-05
2.56E-05 -2.13E-05
1.69E-04 1.23E-04
4.76E-06 -3.10E-05
1.21E-04 8.33E-05
6.69E-05 3.46E-05
5.65E-05 2.15E-05
1.35E-04 8.12E-05
2.67E-04 1.94E-04
6.02E-05 6.05E-05
2.17E-05 3.54E-05 4.87E-05 8.23E-05 8.14E-05 4.58E-05
6.40E-05 6.47E-05 6.58E-05 6.79E-05 6.84E-05 6.91E-05
1.97E-04 2.13E-04 2.29E-04 2.68E-04 2.69E-04 2.35E-04
-1.54E-04 -1.42E-04 -1.32E-04 -1.04E-04 -1.06E-04 -1.44E-04
6.46E-05
6.87E-05
2.53E-04
-1.24E-04
-4.50E-04
PASS
4.50E-04
PASS
7.92E-05
7.17E-05
2.76E-04
-1.17E-04
-4.50E-04
PASS
4.50E-04
PASS
9.44E-05
7.44E-05
2.98E-04
-1.10E-04
-4.50E-04
PASS
4.50E-04
PASS
1.28E-04
8.37E-05
3.57E-04
-1.01E-04
-6.00E-04
PASS
6.00E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
21
1.29E-04
8.41E-05
3.60E-04
-1.01E-04
-6.00E-04
PASS
6.00E-04
PASS
8.29E-05
6.79E-05
2.69E-04
-1.03E-04
-6.00E-04
PASS
6.00E-04
PASS
Offset Current 15V 1 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.7. Plot of Offset Current 15V 1 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid diamonds
are the average of the measured data points for the samples irradiated under electrical bias while the shaded
diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The
black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the
samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted
line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the
datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
22
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.7. Raw data for Offset Current 15V 1 (A) @ VS= +/-15V, VCM= 0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Offset Current 15V 1 (A)
@ VS= +/-15V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
0
-7.40E-11
-3.30E-11
-1.08E-10
1.20E-11
1.00E-10
2.00E-12
4.70E-11
-6.20E-11
-7.10E-11
-4.40E-11
-8.60E-11
Biased Statistics
Average Biased
-2.06E-11
Std Dev Biased
8.10E-11
Ps90%/90% (+KTL) Biased
2.02E-10
Ps90%/90% (-KTL) Biased
-2.43E-10
Un-Biased Statistics
Average Un-Biased
-2.56E-11
Std Dev Un-Biased
4.94E-11
Ps90%/90% (+KTL) Un-Biased
1.10E-10
Ps90%/90% (-KTL) Un-Biased
-1.61E-10
Specification MIN
-1.00E-08
Status
PASS
Specification MAX
1.00E-08
Status
PASS
Total
10
-4.50E-11
2.60E-11
-1.14E-10
3.60E-11
5.50E-11
1.02E-10
-2.50E-11
-9.70E-11
-9.20E-11
-3.60E-11
-6.20E-11
Dose (krad(Si))
20
30
-1.60E-11 -1.73E-10
4.30E-11 3.90E-11
-1.13E-10 -8.50E-11
9.40E-11 2.71E-10
-6.30E-11 -3.20E-11
1.80E-11 -2.10E-11
8.90E-11 7.10E-11
-6.20E-11 -7.60E-11
-8.60E-11 -5.10E-11
-5.60E-11 -3.70E-11
-7.60E-11 -7.60E-11
50
-2.02E-10
1.48E-10
-1.01E-10
2.03E-10
3.90E-11
8.50E-11
2.08E-10
-1.09E-10
5.90E-11
-9.20E-11
-8.90E-11
24 Hr
Anneal
60
-2.12E-10
1.71E-10
-7.20E-11
1.65E-10
-3.00E-11
6.30E-11
1.61E-10
-1.36E-10
9.00E-12
-8.00E-11
-8.10E-11
168 Hr
Anneal
70
-4.30E-10
1.16E-10
-4.60E-11
1.14E-10
-1.69E-10
-6.60E-11
1.15E-10
-7.40E-11
-9.00E-11
-3.40E-11
-9.20E-11
-8.40E-12 -1.10E-11 4.00E-12 1.74E-11 4.40E-12 -8.30E-11
7.01E-11 8.23E-11 1.68E-10 1.69E-10 1.64E-10 2.28E-10
1.84E-10 2.15E-10 4.65E-10 4.81E-10 4.54E-10 5.42E-10
-2.01E-10 -2.37E-10 -4.57E-10 -4.46E-10 -4.45E-10 -7.08E-10
-2.96E-11
8.03E-11
1.91E-10
-2.50E-10
-1.00E-08
PASS
1.00E-08
PASS
-1.94E-11
7.20E-11
1.78E-10
-2.17E-10
-1.00E-08
PASS
1.00E-08
PASS
-2.28E-11
5.62E-11
1.31E-10
-1.77E-10
-1.00E-08
PASS
1.00E-08
PASS
3.02E-11
1.32E-10
3.92E-10
-3.32E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
23
3.40E-12
1.17E-10
3.24E-10
-3.18E-10
-1.50E-08
PASS
1.50E-08
PASS
-2.98E-11
8.35E-11
1.99E-10
-2.59E-10
-1.50E-08
PASS
1.50E-08
PASS
Offset Current 15V 2 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.8. Plot of Offset Current 15V 2 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid diamonds
are the average of the measured data points for the samples irradiated under electrical bias while the shaded
diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The
black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the
samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted
line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the
datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
24
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.8. Raw data for Offset Current 15V 2 (A) @ VS= +/-15V, VCM= 0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Offset Current 15V 2 (A)
@ VS= +/-15V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
0
-1.70E-11
-4.80E-11
-3.40E-11
-9.30E-11
-1.23E-10
3.70E-11
6.00E-12
1.12E-10
-5.60E-11
-4.50E-11
-5.30E-11
Biased Statistics
Average Biased
-6.30E-11
Std Dev Biased
4.38E-11
Ps90%/90% (+KTL) Biased
5.72E-11
Ps90%/90% (-KTL) Biased
-1.83E-10
Un-Biased Statistics
Average Un-Biased
1.08E-11
Std Dev Un-Biased
6.81E-11
Ps90%/90% (+KTL) Un-Biased
1.97E-10
Ps90%/90% (-KTL) Un-Biased
-1.76E-10
Specification MIN
-1.00E-08
Status
PASS
Specification MAX
1.00E-08
Status
PASS
Total
10
6.70E-11
5.00E-12
-9.30E-11
-1.40E-11
-1.60E-10
9.00E-11
2.30E-11
1.39E-10
1.60E-11
5.50E-11
-6.40E-11
24 Hr
168 Hr
Dose (krad(Si))
Anneal
Anneal
20
30
50
60
70
1.90E-11 1.21E-10 1.64E-10 1.07E-10 2.40E-11
7.60E-11 9.70E-11 1.73E-10 1.18E-10 1.10E-10
4.90E-11 -4.50E-11 -1.98E-10 -1.70E-10 -2.03E-10
6.50E-11 9.70E-11 1.05E-10 1.00E-10 5.90E-11
-2.07E-10 -1.32E-10 -2.45E-10 -2.90E-10 -3.60E-10
3.80E-11 2.40E-11 1.42E-10 1.57E-10 1.27E-10
-3.30E-11 6.30E-11 1.45E-10 1.46E-10 4.00E-11
1.69E-10 2.21E-10 2.81E-10 3.15E-10 1.68E-10
1.50E-11 1.50E-11 6.10E-11 4.90E-11 -1.80E-11
4.10E-11 -1.30E-11 4.00E-11 2.90E-11 -2.70E-11
-4.70E-11 -3.30E-11 -6.70E-11 -5.70E-11 -4.30E-11
-3.90E-11 4.00E-13 2.76E-11 -2.00E-13 -2.70E-11 -7.40E-11
8.85E-11 1.18E-10 1.11E-10 2.04E-10 1.90E-10 2.00E-10
2.04E-10 3.24E-10 3.31E-10 5.60E-10 4.95E-10 4.74E-10
-2.82E-10 -3.23E-10 -2.76E-10 -5.61E-10 -5.49E-10 -6.22E-10
6.46E-11
5.09E-11
2.04E-10
-7.50E-11
-1.00E-08
PASS
1.00E-08
PASS
4.60E-11
7.49E-11
2.51E-10
-1.59E-10
-1.00E-08
PASS
1.00E-08
PASS
6.20E-11
9.30E-11
3.17E-10
-1.93E-10
-1.00E-08
PASS
1.00E-08
PASS
1.34E-10
9.48E-11
3.94E-10
-1.26E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
25
1.39E-10
1.14E-10
4.50E-10
-1.72E-10
-1.50E-08
PASS
1.50E-08
PASS
5.80E-11
8.69E-11
2.96E-10
-1.80E-10
-1.50E-08
PASS
1.50E-08
PASS
Offset Current 15V 3 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.9. Plot of Offset Current 15V 3 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid diamonds
are the average of the measured data points for the samples irradiated under electrical bias while the shaded
diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The
black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the
samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted
line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the
datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
26
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.9. Raw data for Offset Current 15V 3 (A) @ VS= +/-15V, VCM= 0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Offset Current 15V 3 (A)
@ VS= +/-15V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
0
4.50E-11
-5.40E-11
3.70E-11
-1.50E-11
-2.60E-11
-9.00E-12
-1.32E-10
-4.00E-11
-2.10E-11
-9.00E-12
1.15E-10
Biased Statistics
Average Biased
-2.60E-12
Std Dev Biased
4.24E-11
Ps90%/90% (+KTL) Biased
1.14E-10
Ps90%/90% (-KTL) Biased
-1.19E-10
Un-Biased Statistics
Average Un-Biased
-4.22E-11
Std Dev Un-Biased
5.18E-11
Ps90%/90% (+KTL) Un-Biased
9.98E-11
Ps90%/90% (-KTL) Un-Biased
-1.84E-10
Specification MIN
-1.00E-08
Status
PASS
Specification MAX
1.00E-08
Status
PASS
Total
10
5.80E-11
1.13E-10
-1.90E-11
-1.03E-10
-8.70E-11
-7.60E-11
-1.12E-10
-1.20E-11
6.00E-12
-2.90E-11
1.21E-10
Dose (krad(Si))
20
30
-4.00E-12 1.53E-10
7.50E-11 9.60E-11
-5.00E-11 -1.55E-10
-1.68E-10 -1.84E-10
-1.10E-10 -8.20E-11
-1.90E-11 -9.00E-12
-1.73E-10 -1.35E-10
-5.30E-11 8.20E-11
9.00E-12 -5.50E-11
-2.00E-12 -1.15E-10
7.00E-11 1.22E-10
50
2.01E-10
1.83E-10
-8.80E-11
-1.93E-10
-2.84E-10
2.60E-11
-9.10E-11
2.60E-11
-3.60E-11
-9.90E-11
1.16E-10
24 Hr
Anneal
60
1.79E-10
1.56E-10
-1.06E-10
-2.40E-10
-2.80E-10
4.10E-11
-7.30E-11
8.40E-11
-3.40E-11
-1.11E-10
1.33E-10
168 Hr
Anneal
70
-1.23E-10
-1.05E-10
6.00E-12
-7.90E-11
-1.35E-10
-5.90E-11
-1.72E-10
6.00E-11
6.10E-11
-2.24E-10
1.23E-10
-7.60E-12 -5.14E-11 -3.44E-11 -3.62E-11 -5.82E-11 -8.72E-11
9.27E-11 9.39E-11 1.51E-10 2.20E-10 2.16E-10 5.62E-11
2.47E-10 2.06E-10 3.80E-10 5.66E-10 5.34E-10 6.69E-11
-2.62E-10 -3.09E-10 -4.49E-10 -6.38E-10 -6.51E-10 -2.41E-10
-4.46E-11
4.85E-11
8.83E-11
-1.77E-10
-1.00E-08
PASS
1.00E-08
PASS
-4.76E-11
7.39E-11
1.55E-10
-2.50E-10
-1.00E-08
PASS
1.00E-08
PASS
-4.64E-11
8.73E-11
1.93E-10
-2.86E-10
-1.00E-08
PASS
1.00E-08
PASS
-3.48E-11
6.06E-11
1.31E-10
-2.01E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
27
-1.86E-11
8.03E-11
2.02E-10
-2.39E-10
-1.50E-08
PASS
1.50E-08
PASS
-6.68E-11
1.31E-10
2.91E-10
-4.25E-10
-1.50E-08
PASS
1.50E-08
PASS
Offset Current 15V 4 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.10. Plot of Offset Current 15V 4 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid diamonds
are the average of the measured data points for the samples irradiated under electrical bias while the shaded
diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The
black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the
samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted
line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the
datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
28
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.10. Raw data for Offset Current 15V 4 (A) @ VS= +/-15V, VCM= 0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Offset Current 15V 4 (A)
@ VS= +/-15V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
0
-2.00E-12
-9.20E-11
-2.00E-11
-7.80E-11
-2.60E-11
1.00E-11
-4.40E-11
1.30E-11
-2.20E-11
-3.30E-11
0.00E+00
Biased Statistics
Average Biased
-4.36E-11
Std Dev Biased
3.91E-11
Ps90%/90% (+KTL) Biased
6.37E-11
Ps90%/90% (-KTL) Biased
-1.51E-10
Un-Biased Statistics
Average Un-Biased
-1.52E-11
Std Dev Un-Biased
2.56E-11
Ps90%/90% (+KTL) Un-Biased
5.50E-11
Ps90%/90% (-KTL) Un-Biased
-8.54E-11
Specification MIN
-1.00E-08
Status
PASS
Specification MAX
1.00E-08
Status
PASS
Total
10
-1.90E-11
-1.45E-10
-1.40E-11
-2.40E-11
3.90E-11
1.90E-11
-2.60E-11
8.00E-12
-2.10E-11
-1.10E-11
2.40E-11
Dose (krad(Si))
20
30
-6.40E-11 -1.07E-10
-9.90E-11 -2.44E-10
-5.60E-11 -1.04E-10
6.70E-11 8.90E-11
-1.22E-10 -8.80E-11
8.00E-12 -4.20E-11
-2.40E-11 -3.00E-11
-1.40E-11 -1.70E-11
-4.00E-12 -8.20E-11
8.00E-12 6.00E-11
2.40E-11 2.40E-11
50
-4.10E-11
-1.59E-10
-1.16E-10
1.03E-10
-2.33E-10
4.50E-11
-2.10E-11
1.20E-11
-8.90E-11
1.31E-10
1.10E-11
24 Hr
168 Hr
Anneal
Anneal
60
70
3.90E-11 9.60E-11
-1.16E-10 -1.97E-10
-1.34E-10 3.00E-12
1.03E-10 1.38E-10
-2.47E-10 -2.02E-10
-5.80E-11 -5.60E-11
-1.30E-10 1.03E-10
-5.20E-11 6.20E-11
-1.60E-10 6.20E-11
9.00E-11 8.20E-11
2.80E-11 1.50E-11
-3.26E-11 -5.48E-11 -9.08E-11 -8.92E-11 -7.10E-11 -3.24E-11
6.78E-11 7.31E-11 1.19E-10 1.28E-10 1.41E-10 1.60E-10
1.53E-10 1.46E-10 2.34E-10 2.62E-10 3.15E-10 4.07E-10
-2.18E-10 -2.55E-10 -4.16E-10 -4.40E-10 -4.57E-10 -4.72E-10
-6.20E-12
1.92E-11
4.64E-11
-5.88E-11
-1.00E-08
PASS
1.00E-08
PASS
-5.20E-12
1.40E-11
3.31E-11
-4.35E-11
-1.00E-08
PASS
1.00E-08
PASS
-2.22E-11
5.20E-11
1.20E-10
-1.65E-10
-1.00E-08
PASS
1.00E-08
PASS
1.56E-11
8.14E-11
2.39E-10
-2.07E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
29
-6.20E-11
9.68E-11
2.03E-10
-3.27E-10
-1.50E-08
PASS
1.50E-08
PASS
5.06E-11
6.20E-11
2.20E-10
-1.19E-10
-1.50E-08
PASS
1.50E-08
PASS
Positive Bias Current 15V 1 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.11. Plot of Positive Bias Current 15V 1 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
30
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.11. Raw data for Positive Bias Current 15V 1 (A) @ VS= +/-15V, VCM= 0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Positive Bias Current 15V 1 (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +/-15V, VCM= 0V
Device
0
10
20
30
50
60
70
59 1.07E-08 1.35E-08 1.73E-08 2.10E-08 2.95E-08 2.98E-08 2.72E-08
149 1.03E-08 1.30E-08 1.69E-08 2.06E-08 2.88E-08 2.90E-08 2.61E-08
233 1.07E-08 1.33E-08 1.70E-08 2.07E-08 2.91E-08 2.93E-08 2.68E-08
310 1.05E-08 1.34E-08 1.71E-08 2.07E-08 2.94E-08 2.95E-08 2.70E-08
393 1.03E-08 1.33E-08 1.73E-08 2.10E-08 2.97E-08 2.99E-08 2.71E-08
443 1.06E-08 1.27E-08 1.52E-08 1.74E-08 2.26E-08 2.26E-08 2.04E-08
516 9.98E-09 1.21E-08 1.45E-08 1.65E-08 2.14E-08 2.15E-08 1.94E-08
574 1.01E-08 1.24E-08 1.47E-08 1.68E-08 2.19E-08 2.19E-08 1.97E-08
589 1.11E-08 1.33E-08 1.57E-08 1.79E-08 2.31E-08 2.31E-08 2.11E-08
732 1.05E-08 1.26E-08 1.50E-08 1.71E-08 2.22E-08 2.22E-08 2.01E-08
829 1.11E-08 1.11E-08 1.11E-08 1.12E-08 1.11E-08 1.11E-08 1.11E-08
Biased Statistics
Average Biased
1.05E-08 1.33E-08 1.71E-08 2.08E-08 2.93E-08 2.95E-08 2.68E-08
Std Dev Biased
1.82E-10 1.89E-10 1.71E-10 2.02E-10 3.58E-10 3.57E-10 4.51E-10
Ps90%/90% (+KTL) Biased
1.10E-08 1.38E-08 1.76E-08 2.13E-08 3.03E-08 3.05E-08 2.81E-08
Ps90%/90% (-KTL) Biased
1.00E-08 1.28E-08 1.66E-08 2.02E-08 2.83E-08 2.85E-08 2.56E-08
Un-Biased Statistics
Average Un-Biased
1.05E-08 1.26E-08 1.50E-08 1.71E-08 2.22E-08 2.23E-08 2.01E-08
Std Dev Un-Biased
4.35E-10 4.30E-10 4.62E-10 5.31E-10 6.36E-10 6.12E-10 6.65E-10
Ps90%/90% (+KTL) Un-Biased
1.16E-08 1.38E-08 1.63E-08 1.86E-08 2.40E-08 2.39E-08 2.20E-08
Ps90%/90% (-KTL) Un-Biased
9.26E-09 1.14E-08 1.37E-08 1.57E-08 2.05E-08 2.06E-08 1.83E-08
Specification MIN
-3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 -1.00E-07 -1.00E-07 -1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08 6.00E-08 7.50E-08 7.50E-08 1.00E-07 1.00E-07 1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
31
Positive Bias Current 15V 2 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.12. Plot of Positive Bias Current 15V 2 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
32
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.12. Raw data for Positive Bias Current 15V 2 (A) @ VS= +/-15V, VCM= 0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Positive Bias Current 15V 2 (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +/-15V, VCM= 0V
Device
0
10
20
30
50
60
70
59 1.04E-08 1.30E-08 1.68E-08 2.03E-08 2.86E-08 2.89E-08 2.65E-08
149 1.00E-08 1.26E-08 1.63E-08 1.99E-08 2.80E-08 2.82E-08 2.53E-08
233 1.04E-08 1.31E-08 1.69E-08 2.07E-08 2.93E-08 2.94E-08 2.69E-08
310 1.09E-08 1.36E-08 1.74E-08 2.11E-08 2.96E-08 2.98E-08 2.72E-08
393 1.03E-08 1.31E-08 1.70E-08 2.07E-08 2.93E-08 2.95E-08 2.66E-08
443 9.62E-09 1.17E-08 1.40E-08 1.60E-08 2.09E-08 2.09E-08 1.87E-08
516 1.03E-08 1.23E-08 1.48E-08 1.68E-08 2.17E-08 2.17E-08 1.96E-08
574 9.64E-09 1.17E-08 1.39E-08 1.60E-08 2.08E-08 2.08E-08 1.86E-08
589 1.07E-08 1.29E-08 1.52E-08 1.75E-08 2.26E-08 2.26E-08 2.06E-08
732 1.03E-08 1.23E-08 1.46E-08 1.68E-08 2.17E-08 2.18E-08 1.96E-08
829 1.01E-08 1.00E-08 1.01E-08 1.01E-08 1.01E-08 1.01E-08 1.01E-08
Biased Statistics
Average Biased
1.04E-08 1.31E-08 1.69E-08 2.05E-08 2.90E-08 2.92E-08 2.65E-08
Std Dev Biased
3.02E-10 3.53E-10 3.96E-10 4.53E-10 6.25E-10 6.11E-10 7.14E-10
Ps90%/90% (+KTL) Biased
1.12E-08 1.41E-08 1.79E-08 2.18E-08 3.07E-08 3.08E-08 2.85E-08
Ps90%/90% (-KTL) Biased
9.58E-09 1.21E-08 1.58E-08 1.93E-08 2.72E-08 2.75E-08 2.46E-08
Un-Biased Statistics
Average Un-Biased
1.01E-08 1.22E-08 1.45E-08 1.66E-08 2.15E-08 2.16E-08 1.94E-08
Std Dev Un-Biased
4.65E-10 4.96E-10 5.55E-10 6.25E-10 7.50E-10 7.53E-10 8.27E-10
Ps90%/90% (+KTL) Un-Biased
1.14E-08 1.35E-08 1.60E-08 1.83E-08 2.36E-08 2.36E-08 2.17E-08
Ps90%/90% (-KTL) Un-Biased
8.83E-09 1.08E-08 1.30E-08 1.49E-08 1.95E-08 1.95E-08 1.72E-08
Specification MIN
-3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 -1.00E-07 -1.00E-07 -1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08 6.00E-08 7.50E-08 7.50E-08 1.00E-07 1.00E-07 1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
33
Positive Bias Current 15V 3 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.13. Plot of Positive Bias Current 15V 3 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
34
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.13. Raw data for Positive Bias Current 15V 3 (A) @ VS= +/-15V, VCM= 0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Positive Bias Current 15V 3 (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +/-15V, VCM= 0V
Device
0
10
20
30
50
60
70
59 1.14E-08 1.42E-08 1.82E-08 2.19E-08 3.08E-08 3.11E-08 2.88E-08
149 1.04E-08 1.32E-08 1.70E-08 2.08E-08 2.91E-08 2.93E-08 2.64E-08
233 1.02E-08 1.30E-08 1.68E-08 2.05E-08 2.90E-08 2.91E-08 2.64E-08
310 1.11E-08 1.41E-08 1.80E-08 2.19E-08 3.06E-08 3.09E-08 2.83E-08
393 1.06E-08 1.35E-08 1.75E-08 2.13E-08 3.02E-08 3.03E-08 2.73E-08
443 1.06E-08 1.27E-08 1.51E-08 1.73E-08 2.25E-08 2.25E-08 2.02E-08
516 1.07E-08 1.28E-08 1.53E-08 1.72E-08 2.24E-08 2.24E-08 2.02E-08
574 1.06E-08 1.28E-08 1.51E-08 1.74E-08 2.25E-08 2.25E-08 2.03E-08
589 1.10E-08 1.31E-08 1.57E-08 1.79E-08 2.33E-08 2.32E-08 2.11E-08
732 1.07E-08 1.28E-08 1.51E-08 1.73E-08 2.24E-08 2.25E-08 2.05E-08
829 1.04E-08 1.04E-08 1.04E-08 1.05E-08 1.03E-08 1.05E-08 1.04E-08
Biased Statistics
Average Biased
1.07E-08 1.36E-08 1.75E-08 2.13E-08 2.99E-08 3.01E-08 2.74E-08
Std Dev Biased
5.04E-10 5.23E-10 6.27E-10 6.42E-10 8.29E-10 8.89E-10 1.08E-09
Ps90%/90% (+KTL) Biased
1.21E-08 1.50E-08 1.92E-08 2.30E-08 3.22E-08 3.26E-08 3.04E-08
Ps90%/90% (-KTL) Biased
9.36E-09 1.22E-08 1.58E-08 1.95E-08 2.77E-08 2.77E-08 2.45E-08
Un-Biased Statistics
Average Un-Biased
1.07E-08 1.28E-08 1.53E-08 1.74E-08 2.26E-08 2.26E-08 2.04E-08
Std Dev Un-Biased
1.61E-10 1.44E-10 2.33E-10 2.68E-10 3.66E-10 3.52E-10 3.64E-10
Ps90%/90% (+KTL) Un-Biased
1.12E-08 1.32E-08 1.59E-08 1.82E-08 2.36E-08 2.36E-08 2.14E-08
Ps90%/90% (-KTL) Un-Biased
1.03E-08 1.25E-08 1.46E-08 1.67E-08 2.16E-08 2.16E-08 1.94E-08
Specification MIN
-3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 -1.00E-07 -1.00E-07 -1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08 6.00E-08 7.50E-08 7.50E-08 1.00E-07 1.00E-07 1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
35
Positive Bias Current 15V 4 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.14. Plot of Positive Bias Current 15V 4 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
36
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.14. Raw data for Positive Bias Current 15V 4 (A) @ VS= +/-15V, VCM= 0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Positive Bias Current 15V 4 (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +/-15V, VCM= 0V
Device
0
10
20
30
50
60
70
59 1.05E-08 1.32E-08 1.70E-08 2.05E-08 2.87E-08 2.90E-08 2.63E-08
149 9.93E-09 1.26E-08 1.63E-08 1.99E-08 2.79E-08 2.79E-08 2.52E-08
233 9.72E-09 1.23E-08 1.58E-08 1.92E-08 2.71E-08 2.72E-08 2.47E-08
310 1.03E-08 1.31E-08 1.68E-08 2.03E-08 2.86E-08 2.88E-08 2.64E-08
393 9.61E-09 1.24E-08 1.61E-08 1.97E-08 2.80E-08 2.81E-08 2.52E-08
443 1.01E-08 1.22E-08 1.46E-08 1.67E-08 2.16E-08 2.17E-08 1.95E-08
516 9.67E-09 1.17E-08 1.41E-08 1.60E-08 2.09E-08 2.09E-08 1.88E-08
574 9.72E-09 1.18E-08 1.40E-08 1.62E-08 2.10E-08 2.10E-08 1.88E-08
589 1.06E-08 1.26E-08 1.49E-08 1.71E-08 2.22E-08 2.23E-08 2.02E-08
732 1.03E-08 1.23E-08 1.45E-08 1.67E-08 2.17E-08 2.18E-08 1.96E-08
829 1.07E-08 1.06E-08 1.06E-08 1.07E-08 1.06E-08 1.07E-08 1.07E-08
Biased Statistics
Average Biased
1.00E-08 1.27E-08 1.64E-08 1.99E-08 2.81E-08 2.82E-08 2.56E-08
Std Dev Biased
3.77E-10 4.38E-10 4.73E-10 5.38E-10 6.44E-10 6.97E-10 7.52E-10
Ps90%/90% (+KTL) Biased
1.10E-08 1.39E-08 1.77E-08 2.14E-08 2.98E-08 3.01E-08 2.76E-08
Ps90%/90% (-KTL) Biased
8.98E-09 1.15E-08 1.51E-08 1.84E-08 2.63E-08 2.63E-08 2.35E-08
Un-Biased Statistics
Average Un-Biased
1.01E-08 1.21E-08 1.44E-08 1.65E-08 2.15E-08 2.15E-08 1.94E-08
Std Dev Un-Biased
4.08E-10 3.68E-10 3.76E-10 4.44E-10 5.48E-10 5.89E-10 5.83E-10
Ps90%/90% (+KTL) Un-Biased
1.12E-08 1.31E-08 1.55E-08 1.77E-08 2.30E-08 2.32E-08 2.10E-08
Ps90%/90% (-KTL) Un-Biased
8.97E-09 1.11E-08 1.34E-08 1.53E-08 2.00E-08 1.99E-08 1.78E-08
Specification MIN
-3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 -1.00E-07 -1.00E-07 -1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08 6.00E-08 7.50E-08 7.50E-08 1.00E-07 1.00E-07 1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
37
Negative Bias Current 15V 1 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.15. Plot of Negative Bias Current 15V 1 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
38
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.15. Raw data for Negative Bias Current 15V 1 (A) @ VS= +/-15V, VCM= 0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Negative Bias Current 15V 1 (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +/-15V, VCM= 0V
Device
0
10
20
30
50
60
70
59 1.07E-08 1.35E-08 1.73E-08 2.08E-08 2.94E-08 2.97E-08 2.69E-08
149 1.03E-08 1.31E-08 1.70E-08 2.06E-08 2.91E-08 2.93E-08 2.63E-08
233 1.06E-08 1.32E-08 1.70E-08 2.06E-08 2.91E-08 2.92E-08 2.68E-08
310 1.05E-08 1.34E-08 1.72E-08 2.10E-08 2.96E-08 2.98E-08 2.71E-08
393 1.04E-08 1.34E-08 1.73E-08 2.11E-08 2.99E-08 2.99E-08 2.69E-08
443 1.06E-08 1.29E-08 1.53E-08 1.75E-08 2.28E-08 2.28E-08 2.04E-08
516 1.00E-08 1.22E-08 1.47E-08 1.66E-08 2.17E-08 2.17E-08 1.96E-08
574 1.01E-08 1.24E-08 1.46E-08 1.68E-08 2.19E-08 2.18E-08 1.97E-08
589 1.10E-08 1.32E-08 1.56E-08 1.78E-08 2.33E-08 2.32E-08 2.11E-08
732 1.05E-08 1.26E-08 1.49E-08 1.71E-08 2.22E-08 2.22E-08 2.01E-08
829 1.10E-08 1.10E-08 1.10E-08 1.10E-08 1.11E-08 1.11E-08 1.10E-08
Biased Statistics
Average Biased
1.05E-08 1.33E-08 1.72E-08 2.08E-08 2.94E-08 2.96E-08 2.68E-08
Std Dev Biased
1.44E-10 1.71E-10 1.58E-10 1.97E-10 3.27E-10 3.10E-10 3.14E-10
Ps90%/90% (+KTL) Biased
1.09E-08 1.38E-08 1.76E-08 2.14E-08 3.03E-08 3.04E-08 2.77E-08
Ps90%/90% (-KTL) Biased
1.01E-08 1.29E-08 1.67E-08 2.03E-08 2.85E-08 2.87E-08 2.59E-08
Un-Biased Statistics
Average Un-Biased
1.05E-08 1.27E-08 1.50E-08 1.72E-08 2.24E-08 2.23E-08 2.02E-08
Std Dev Un-Biased
3.98E-10 4.12E-10 4.16E-10 4.91E-10 6.54E-10 6.12E-10 6.17E-10
Ps90%/90% (+KTL) Un-Biased
1.16E-08 1.38E-08 1.62E-08 1.85E-08 2.42E-08 2.40E-08 2.19E-08
Ps90%/90% (-KTL) Un-Biased
9.37E-09 1.15E-08 1.39E-08 1.58E-08 2.06E-08 2.07E-08 1.85E-08
Specification MIN
-3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 -1.00E-07 -1.00E-07 -1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08 6.00E-08 7.50E-08 7.50E-08 1.00E-07 1.00E-07 1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
39
Negative Bias Current 15V 2 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.16. Plot of Negative Bias Current 15V 2 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
40
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.16. Raw data for Negative Bias Current 15V 2 (A) @ VS= +/-15V, VCM= 0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Negative Bias Current 15V 2 (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +/-15V, VCM= 0V
Device
0
10
20
30
50
60
70
59 1.04E-08 1.31E-08 1.69E-08 2.04E-08 2.88E-08 2.91E-08 2.66E-08
149 9.97E-09 1.27E-08 1.64E-08 2.00E-08 2.83E-08 2.85E-08 2.55E-08
233 1.03E-08 1.31E-08 1.70E-08 2.06E-08 2.91E-08 2.94E-08 2.68E-08
310 1.08E-08 1.36E-08 1.75E-08 2.12E-08 2.98E-08 2.99E-08 2.74E-08
393 1.02E-08 1.30E-08 1.69E-08 2.06E-08 2.91E-08 2.93E-08 2.63E-08
443 9.72E-09 1.18E-08 1.41E-08 1.61E-08 2.11E-08 2.10E-08 1.88E-08
516 1.03E-08 1.24E-08 1.48E-08 1.69E-08 2.20E-08 2.19E-08 1.96E-08
574 9.78E-09 1.19E-08 1.42E-08 1.62E-08 2.11E-08 2.11E-08 1.88E-08
589 1.07E-08 1.30E-08 1.53E-08 1.75E-08 2.27E-08 2.27E-08 2.07E-08
732 1.03E-08 1.24E-08 1.47E-08 1.68E-08 2.19E-08 2.19E-08 1.97E-08
829 1.00E-08 1.00E-08 9.97E-09 1.01E-08 1.01E-08 1.00E-08 1.00E-08
Biased Statistics
Average Biased
1.03E-08 1.31E-08 1.69E-08 2.06E-08 2.90E-08 2.92E-08 2.65E-08
Std Dev Biased
3.11E-10 3.36E-10 3.86E-10 4.31E-10 5.48E-10 5.31E-10 6.91E-10
Ps90%/90% (+KTL) Biased
1.12E-08 1.40E-08 1.80E-08 2.18E-08 3.05E-08 3.07E-08 2.84E-08
Ps90%/90% (-KTL) Biased
9.49E-09 1.22E-08 1.59E-08 1.94E-08 2.75E-08 2.78E-08 2.46E-08
Un-Biased Statistics
Average Un-Biased
1.02E-08 1.23E-08 1.46E-08 1.67E-08 2.18E-08 2.17E-08 1.95E-08
Std Dev Un-Biased
4.17E-10 4.90E-10 4.88E-10 5.55E-10 6.86E-10 6.80E-10 7.60E-10
Ps90%/90% (+KTL) Un-Biased
1.13E-08 1.36E-08 1.60E-08 1.82E-08 2.36E-08 2.36E-08 2.16E-08
Ps90%/90% (-KTL) Un-Biased
9.02E-09 1.09E-08 1.33E-08 1.52E-08 1.99E-08 1.99E-08 1.74E-08
Specification MIN
-3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 -1.00E-07 -1.00E-07 -1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08 6.00E-08 7.50E-08 7.50E-08 1.00E-07 1.00E-07 1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
41
Negative Bias Current 15V 3 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.17. Plot of Negative Bias Current 15V 3 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
42
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.17. Raw data for Negative Bias Current 15V 3 (A) @ VS= +/-15V, VCM= 0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Negative Bias Current 15V 3 (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +/-15V, VCM= 0V
Device
0
10
20
30
50
60
70
59 1.14E-08 1.43E-08 1.82E-08 2.21E-08 3.11E-08 3.13E-08 2.87E-08
149 1.05E-08 1.34E-08 1.71E-08 2.09E-08 2.94E-08 2.95E-08 2.64E-08
233 1.02E-08 1.31E-08 1.68E-08 2.03E-08 2.90E-08 2.92E-08 2.65E-08
310 1.11E-08 1.40E-08 1.80E-08 2.18E-08 3.05E-08 3.07E-08 2.82E-08
393 1.05E-08 1.34E-08 1.74E-08 2.13E-08 2.99E-08 3.01E-08 2.72E-08
443 1.07E-08 1.27E-08 1.52E-08 1.74E-08 2.26E-08 2.26E-08 2.03E-08
516 1.05E-08 1.27E-08 1.52E-08 1.71E-08 2.25E-08 2.24E-08 2.01E-08
574 1.06E-08 1.28E-08 1.52E-08 1.75E-08 2.26E-08 2.26E-08 2.03E-08
589 1.11E-08 1.32E-08 1.57E-08 1.79E-08 2.33E-08 2.33E-08 2.12E-08
732 1.07E-08 1.28E-08 1.52E-08 1.73E-08 2.25E-08 2.24E-08 2.02E-08
829 1.06E-08 1.05E-08 1.05E-08 1.06E-08 1.05E-08 1.06E-08 1.06E-08
Biased Statistics
Average Biased
1.07E-08 1.36E-08 1.75E-08 2.13E-08 3.00E-08 3.02E-08 2.74E-08
Std Dev Biased
5.04E-10 5.03E-10 5.99E-10 6.97E-10 8.44E-10 8.73E-10 1.04E-09
Ps90%/90% (+KTL) Biased
1.21E-08 1.50E-08 1.91E-08 2.32E-08 3.23E-08 3.26E-08 3.03E-08
Ps90%/90% (-KTL) Biased
9.35E-09 1.23E-08 1.59E-08 1.94E-08 2.77E-08 2.78E-08 2.46E-08
Un-Biased Statistics
Average Un-Biased
1.07E-08 1.29E-08 1.53E-08 1.74E-08 2.27E-08 2.27E-08 2.04E-08
Std Dev Un-Biased
2.09E-10 1.90E-10 2.15E-10 2.96E-10 3.53E-10 3.76E-10 4.39E-10
Ps90%/90% (+KTL) Un-Biased
1.13E-08 1.34E-08 1.59E-08 1.82E-08 2.37E-08 2.37E-08 2.16E-08
Ps90%/90% (-KTL) Un-Biased
1.01E-08 1.23E-08 1.47E-08 1.66E-08 2.17E-08 2.16E-08 1.92E-08
Specification MIN
-3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 -1.00E-07 -1.00E-07 -1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08 6.00E-08 7.50E-08 7.50E-08 1.00E-07 1.00E-07 1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
43
Negative Bias Current 15V 4 (A) @ VS= +/-15V, VCM= 0V
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.18. Plot of Negative Bias Current 15V 4 (A) @ VS= +/-15V, VCM= 0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
44
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.18. Raw data for Negative Bias Current 15V 4 (A) @ VS= +/-15V, VCM= 0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Negative Bias Current 15V 4 (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +/-15V, VCM= 0V
Device
0
10
20
30
50
60
70
59 1.05E-08 1.32E-08 1.69E-08 2.05E-08 2.87E-08 2.91E-08 2.65E-08
149 9.83E-09 1.26E-08 1.62E-08 1.97E-08 2.77E-08 2.79E-08 2.51E-08
233 9.70E-09 1.22E-08 1.58E-08 1.91E-08 2.70E-08 2.72E-08 2.48E-08
310 1.03E-08 1.32E-08 1.69E-08 2.05E-08 2.88E-08 2.90E-08 2.65E-08
393 9.61E-09 1.25E-08 1.61E-08 1.97E-08 2.78E-08 2.79E-08 2.50E-08
443 1.02E-08 1.23E-08 1.46E-08 1.67E-08 2.18E-08 2.19E-08 1.95E-08
516 9.60E-09 1.18E-08 1.41E-08 1.60E-08 2.09E-08 2.09E-08 1.90E-08
574 9.69E-09 1.18E-08 1.41E-08 1.62E-08 2.10E-08 2.10E-08 1.90E-08
589 1.07E-08 1.26E-08 1.50E-08 1.71E-08 2.22E-08 2.22E-08 2.03E-08
732 1.03E-08 1.23E-08 1.46E-08 1.68E-08 2.20E-08 2.19E-08 1.97E-08
829 1.07E-08 1.07E-08 1.06E-08 1.07E-08 1.07E-08 1.07E-08 1.07E-08
Biased Statistics
Average Biased
9.99E-09 1.27E-08 1.64E-08 1.99E-08 2.80E-08 2.82E-08 2.56E-08
Std Dev Biased
3.96E-10 4.38E-10 4.96E-10 5.82E-10 7.35E-10 8.03E-10 8.41E-10
Ps90%/90% (+KTL) Biased
1.11E-08 1.39E-08 1.77E-08 2.15E-08 3.00E-08 3.04E-08 2.79E-08
Ps90%/90% (-KTL) Biased
8.90E-09 1.15E-08 1.50E-08 1.83E-08 2.60E-08 2.60E-08 2.33E-08
Un-Biased Statistics
Average Un-Biased
1.01E-08 1.22E-08 1.45E-08 1.66E-08 2.16E-08 2.16E-08 1.95E-08
Std Dev Un-Biased
4.39E-10 3.66E-10 3.77E-10 4.49E-10 5.79E-10 5.85E-10 5.50E-10
Ps90%/90% (+KTL) Un-Biased
1.13E-08 1.32E-08 1.55E-08 1.78E-08 2.32E-08 2.32E-08 2.10E-08
Ps90%/90% (-KTL) Un-Biased
8.88E-09 1.12E-08 1.34E-08 1.53E-08 2.00E-08 2.00E-08 1.80E-08
Specification MIN
-3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 -1.00E-07 -1.00E-07 -1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08 6.00E-08 7.50E-08 7.50E-08 1.00E-07 1.00E-07 1.00E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
45
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio 1 (dB)
@ VS= +/-15V, VCM= 13V, -15V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.19. Plot of Common Mode Rejection Ratio 1 (dB) @ VS= +/-15V, VCM= 13V, -15V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
46
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.19. Raw data for Common Mode Rejection Ratio 1 (dB) @ VS= +/-15V, VCM= 13V, -15V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio 1 (dB)
@ VS= +/-15V, VCM= 13V, -15V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.15E+02
1.14E+02
1.12E+02
1.09E+02
1.14E+02
1.14E+02
1.20E+02
1.21E+02
1.08E+02
1.09E+02
1.14E+02
24 Hr
Anneal
60
1.15E+02
1.14E+02
1.12E+02
1.09E+02
1.14E+02
1.14E+02
1.21E+02
1.21E+02
1.08E+02
1.10E+02
1.13E+02
168 Hr
Anneal
70
1.16E+02
1.14E+02
1.12E+02
1.09E+02
1.15E+02
1.16E+02
1.25E+02
1.25E+02
1.08E+02
1.11E+02
1.14E+02
1.13E+02
2.63E+00
1.20E+02
1.06E+02
1.13E+02
2.50E+00
1.19E+02
1.06E+02
1.13E+02
2.58E+00
1.20E+02
1.06E+02
1.13E+02
2.68E+00
1.20E+02
1.06E+02
1.16E+02
7.14E+00
1.36E+02
9.64E+01
9.70E+01
PASS
1.15E+02
6.09E+00
1.31E+02
9.78E+01
9.40E+01
PASS
1.15E+02
6.15E+00
1.32E+02
9.78E+01
9.40E+01
PASS
1.17E+02
7.74E+00
1.38E+02
9.56E+01
9.40E+01
PASS
0
1.19E+02
1.18E+02
1.15E+02
1.10E+02
1.17E+02
1.18E+02
1.38E+02
1.37E+02
1.09E+02
1.11E+02
1.13E+02
Total
10
1.16E+02
1.15E+02
1.12E+02
1.09E+02
1.15E+02
1.16E+02
1.27E+02
1.29E+02
1.09E+02
1.11E+02
1.14E+02
Dose (krad(Si))
20
30
1.15E+02 1.15E+02
1.14E+02 1.14E+02
1.12E+02 1.12E+02
1.09E+02 1.09E+02
1.14E+02 1.14E+02
1.16E+02 1.15E+02
1.24E+02 1.23E+02
1.25E+02 1.24E+02
1.08E+02 1.08E+02
1.10E+02 1.10E+02
1.14E+02 1.14E+02
1.16E+02
3.54E+00
1.26E+02
1.06E+02
1.13E+02
2.66E+00
1.21E+02
1.06E+02
1.13E+02
2.58E+00
1.20E+02
1.06E+02
1.23E+02
1.38E+01
1.61E+02
8.49E+01
9.70E+01
PASS
1.18E+02
9.11E+00
1.43E+02
9.33E+01
9.70E+01
PASS
1.17E+02
7.67E+00
1.38E+02
9.56E+01
9.70E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
47
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio 2 (dB)
@ VS= +/-15V, VCM= 13V, -15V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.20. Plot of Common Mode Rejection Ratio 2 (dB) @ VS= +/-15V, VCM= 13V, -15V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
48
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.20. Raw data for Common Mode Rejection Ratio 2 (dB) @ VS= +/-15V, VCM= 13V, -15V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio 2 (dB)
@ VS= +/-15V, VCM= 13V, -15V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.11E+02
1.15E+02
1.14E+02
1.12E+02
1.18E+02
1.14E+02
1.13E+02
1.15E+02
1.13E+02
1.11E+02
1.20E+02
24 Hr
Anneal
60
1.12E+02
1.15E+02
1.14E+02
1.12E+02
1.18E+02
1.14E+02
1.13E+02
1.15E+02
1.13E+02
1.11E+02
1.20E+02
168 Hr
Anneal
70
1.12E+02
1.16E+02
1.15E+02
1.13E+02
1.19E+02
1.16E+02
1.15E+02
1.17E+02
1.15E+02
1.13E+02
1.20E+02
1.14E+02
2.79E+00
1.22E+02
1.07E+02
1.14E+02
2.61E+00
1.21E+02
1.07E+02
1.14E+02
2.62E+00
1.21E+02
1.07E+02
1.15E+02
2.72E+00
1.22E+02
1.07E+02
1.14E+02
1.56E+00
1.19E+02
1.10E+02
9.70E+01
PASS
1.13E+02
1.53E+00
1.17E+02
1.09E+02
9.40E+01
PASS
1.13E+02
1.52E+00
1.18E+02
1.09E+02
9.40E+01
PASS
1.15E+02
1.60E+00
1.19E+02
1.11E+02
9.40E+01
PASS
0
1.15E+02
1.19E+02
1.18E+02
1.15E+02
1.24E+02
1.18E+02
1.18E+02
1.20E+02
1.17E+02
1.14E+02
1.21E+02
Total
10
1.12E+02
1.16E+02
1.15E+02
1.12E+02
1.20E+02
1.16E+02
1.16E+02
1.18E+02
1.16E+02
1.13E+02
1.20E+02
Dose (krad(Si))
20
30
1.12E+02 1.12E+02
1.15E+02 1.15E+02
1.15E+02 1.14E+02
1.12E+02 1.12E+02
1.19E+02 1.19E+02
1.15E+02 1.15E+02
1.15E+02 1.14E+02
1.17E+02 1.16E+02
1.15E+02 1.14E+02
1.12E+02 1.12E+02
1.20E+02 1.21E+02
1.18E+02
4.02E+00
1.29E+02
1.07E+02
1.15E+02
2.99E+00
1.23E+02
1.07E+02
1.15E+02
2.88E+00
1.23E+02
1.07E+02
1.17E+02
2.30E+00
1.24E+02
1.11E+02
9.70E+01
PASS
1.16E+02
1.79E+00
1.21E+02
1.11E+02
9.70E+01
PASS
1.15E+02
1.67E+00
1.19E+02
1.10E+02
9.70E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
49
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio 3 (dB)
@ VS= +/-15V, VCM= 13V, -15V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.21. Plot of Common Mode Rejection Ratio 3 (dB) @ VS= +/-15V, VCM= 13V, -15V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
50
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.21. Raw data for Common Mode Rejection Ratio 3 (dB) @ VS= +/-15V, VCM= 13V, -15V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio 3 (dB)
@ VS= +/-15V, VCM= 13V, -15V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.08E+02
1.15E+02
1.10E+02
1.09E+02
1.12E+02
1.14E+02
1.14E+02
1.12E+02
1.09E+02
1.13E+02
1.10E+02
24 Hr
Anneal
60
1.08E+02
1.15E+02
1.10E+02
1.09E+02
1.12E+02
1.14E+02
1.15E+02
1.12E+02
1.09E+02
1.13E+02
1.11E+02
168 Hr
Anneal
70
1.09E+02
1.16E+02
1.11E+02
1.09E+02
1.13E+02
1.15E+02
1.16E+02
1.13E+02
1.10E+02
1.15E+02
1.11E+02
1.11E+02
2.82E+00
1.19E+02
1.03E+02
1.11E+02
2.73E+00
1.18E+02
1.03E+02
1.11E+02
2.77E+00
1.19E+02
1.03E+02
1.12E+02
3.02E+00
1.20E+02
1.03E+02
1.13E+02
2.27E+00
1.20E+02
1.07E+02
9.70E+01
PASS
1.12E+02
2.14E+00
1.18E+02
1.07E+02
9.40E+01
PASS
1.13E+02
2.18E+00
1.19E+02
1.07E+02
9.40E+01
PASS
1.14E+02
2.47E+00
1.21E+02
1.07E+02
9.40E+01
PASS
0
1.10E+02
1.18E+02
1.12E+02
1.10E+02
1.14E+02
1.17E+02
1.21E+02
1.15E+02
1.11E+02
1.17E+02
1.11E+02
Total
10
1.09E+02
1.15E+02
1.11E+02
1.09E+02
1.13E+02
1.16E+02
1.18E+02
1.14E+02
1.10E+02
1.15E+02
1.10E+02
Dose (krad(Si))
20
30
1.09E+02 1.08E+02
1.15E+02 1.15E+02
1.10E+02 1.11E+02
1.09E+02 1.09E+02
1.13E+02 1.13E+02
1.15E+02 1.14E+02
1.17E+02 1.16E+02
1.13E+02 1.13E+02
1.10E+02 1.10E+02
1.14E+02 1.14E+02
1.11E+02 1.11E+02
1.13E+02
3.33E+00
1.22E+02
1.04E+02
1.11E+02
2.71E+00
1.19E+02
1.04E+02
1.11E+02
2.74E+00
1.19E+02
1.04E+02
1.16E+02
3.37E+00
1.25E+02
1.07E+02
9.70E+01
PASS
1.15E+02
2.70E+00
1.22E+02
1.07E+02
9.70E+01
PASS
1.14E+02
2.46E+00
1.21E+02
1.07E+02
9.70E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
51
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio 4 (dB)
@ VS= +/-15V, VCM= 13V, -15V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.22. Plot of Common Mode Rejection Ratio 4 (dB) @ VS= +/-15V, VCM= 13V, -15V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
52
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.22. Raw data for Common Mode Rejection Ratio 4 (dB) @ VS= +/-15V, VCM= 13V, -15V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio 4 (dB)
@ VS= +/-15V, VCM= 13V, -15V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.14E+02
1.20E+02
1.12E+02
1.12E+02
1.09E+02
1.21E+02
1.17E+02
1.11E+02
1.11E+02
1.11E+02
1.20E+02
24 Hr
Anneal
60
1.14E+02
1.20E+02
1.12E+02
1.12E+02
1.09E+02
1.22E+02
1.17E+02
1.12E+02
1.11E+02
1.11E+02
1.20E+02
168 Hr
Anneal
70
1.14E+02
1.23E+02
1.12E+02
1.12E+02
1.09E+02
1.27E+02
1.20E+02
1.13E+02
1.12E+02
1.12E+02
1.20E+02
1.14E+02
4.36E+00
1.26E+02
1.02E+02
1.13E+02
4.06E+00
1.24E+02
1.02E+02
1.13E+02
4.16E+00
1.25E+02
1.02E+02
1.14E+02
5.43E+00
1.29E+02
9.94E+01
1.16E+02
5.57E+00
1.31E+02
1.01E+02
9.70E+01
PASS
1.14E+02
4.61E+00
1.27E+02
1.02E+02
9.40E+01
PASS
1.15E+02
4.74E+00
1.28E+02
1.02E+02
9.40E+01
PASS
1.17E+02
6.72E+00
1.35E+02
9.85E+01
9.40E+01
PASS
0
1.18E+02
1.30E+02
1.14E+02
1.14E+02
1.11E+02
1.39E+02
1.26E+02
1.15E+02
1.15E+02
1.14E+02
1.20E+02
Total
10
1.15E+02
1.21E+02
1.13E+02
1.12E+02
1.10E+02
1.29E+02
1.22E+02
1.14E+02
1.13E+02
1.13E+02
1.20E+02
Dose (krad(Si))
20
30
1.14E+02 1.14E+02
1.21E+02 1.21E+02
1.12E+02 1.12E+02
1.12E+02 1.12E+02
1.09E+02 1.09E+02
1.27E+02 1.24E+02
1.20E+02 1.19E+02
1.13E+02 1.13E+02
1.13E+02 1.12E+02
1.12E+02 1.12E+02
1.20E+02 1.20E+02
1.17E+02
7.61E+00
1.38E+02
9.66E+01
1.14E+02
4.39E+00
1.26E+02
1.02E+02
1.14E+02
4.27E+00
1.25E+02
1.02E+02
1.22E+02
1.08E+01
1.52E+02
9.22E+01
9.70E+01
PASS
1.18E+02
7.32E+00
1.38E+02
9.83E+01
9.70E+01
PASS
1.17E+02
6.41E+00
1.34E+02
9.93E+01
9.70E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
53
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio 1 (dB)
@ VS= +/-10V to +/-18V, VCM= 0V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.23. Plot of Power Supply Rejection Ratio 1 (dB) @ VS= +/-10V to +/-18V, VCM= 0V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
54
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.23. Raw data for Power Supply Rejection Ratio 1 (dB) @ VS= +/-10V to +/-18V, VCM= 0V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio 1 (dB)
@ VS= +/-10V to +/-18V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.39E+02
1.39E+02
1.21E+02
1.23E+02
1.25E+02
1.36E+02
1.30E+02
1.30E+02
1.25E+02
1.23E+02
1.37E+02
24 Hr
Anneal
60
1.40E+02
1.39E+02
1.21E+02
1.23E+02
1.26E+02
1.37E+02
1.31E+02
1.31E+02
1.25E+02
1.23E+02
1.37E+02
168 Hr
Anneal
70
1.51E+02
1.34E+02
1.22E+02
1.24E+02
1.27E+02
1.32E+02
1.26E+02
1.26E+02
1.28E+02
1.27E+02
1.36E+02
1.31E+02
1.05E+01
1.60E+02
1.02E+02
1.29E+02
8.78E+00
1.53E+02
1.05E+02
1.30E+02
9.12E+00
1.55E+02
1.05E+02
1.32E+02
1.18E+01
1.64E+02
9.94E+01
1.28E+02
3.98E+00
1.39E+02
1.18E+02
9.80E+01
PASS
1.29E+02
5.09E+00
1.43E+02
1.15E+02
9.40E+01
PASS
1.29E+02
5.68E+00
1.45E+02
1.14E+02
9.40E+01
PASS
1.28E+02
2.16E+00
1.34E+02
1.22E+02
9.40E+01
PASS
0
1.46E+02
1.33E+02
1.24E+02
1.25E+02
1.29E+02
1.30E+02
1.27E+02
1.26E+02
1.31E+02
1.28E+02
1.39E+02
Total
10
1.46E+02
1.35E+02
1.23E+02
1.24E+02
1.28E+02
1.32E+02
1.27E+02
1.26E+02
1.27E+02
1.28E+02
1.34E+02
Dose (krad(Si))
20
30
1.45E+02 1.47E+02
1.41E+02 1.37E+02
1.22E+02 1.22E+02
1.24E+02 1.23E+02
1.29E+02 1.26E+02
1.34E+02 1.35E+02
1.29E+02 1.26E+02
1.27E+02 1.29E+02
1.26E+02 1.27E+02
1.25E+02 1.24E+02
1.39E+02 1.37E+02
1.31E+02
8.78E+00
1.55E+02
1.07E+02
1.31E+02
9.48E+00
1.57E+02
1.05E+02
1.32E+02
1.03E+01
1.60E+02
1.04E+02
1.28E+02
1.99E+00
1.34E+02
1.23E+02
1.00E+02
PASS
1.28E+02
2.19E+00
1.34E+02
1.22E+02
1.00E+02
PASS
1.28E+02
3.33E+00
1.37E+02
1.19E+02
9.80E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
55
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio 2 (dB)
@ VS= +/-10V to +/-18V, VCM= 0V
1.60E+02
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.24. Plot of Power Supply Rejection Ratio 2 (dB) @ VS= +/-10V to +/-18V, VCM= 0V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
56
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.24. Raw data for Power Supply Rejection Ratio 2 (dB) @ VS= +/-10V to +/-18V, VCM= 0V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio 2 (dB)
@ VS= +/-10V to +/-18V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.37E+02
1.34E+02
1.32E+02
1.24E+02
1.24E+02
1.42E+02
1.30E+02
1.35E+02
1.27E+02
1.21E+02
1.35E+02
24 Hr
Anneal
60
1.37E+02
1.35E+02
1.32E+02
1.24E+02
1.24E+02
1.45E+02
1.30E+02
1.34E+02
1.26E+02
1.21E+02
1.35E+02
168 Hr
Anneal
70
1.69E+02
1.31E+02
1.46E+02
1.26E+02
1.25E+02
1.33E+02
1.39E+02
1.29E+02
1.33E+02
1.24E+02
1.35E+02
1.32E+02
5.82E+00
1.48E+02
1.16E+02
1.30E+02
6.08E+00
1.47E+02
1.13E+02
1.30E+02
6.03E+00
1.47E+02
1.14E+02
1.39E+02
1.86E+01
1.90E+02
8.85E+01
1.32E+02
6.41E+00
1.50E+02
1.15E+02
9.80E+01
PASS
1.31E+02
7.93E+00
1.53E+02
1.10E+02
9.40E+01
PASS
1.31E+02
8.87E+00
1.56E+02
1.07E+02
9.40E+01
PASS
1.31E+02
5.36E+00
1.46E+02
1.17E+02
9.40E+01
PASS
0
1.39E+02
1.30E+02
1.47E+02
1.30E+02
1.29E+02
1.33E+02
1.55E+02
1.27E+02
1.37E+02
1.26E+02
1.36E+02
Total
10
1.56E+02
1.32E+02
1.43E+02
1.26E+02
1.27E+02
1.38E+02
1.45E+02
1.29E+02
1.36E+02
1.25E+02
1.35E+02
Dose (krad(Si))
20
30
1.43E+02 1.38E+02
1.33E+02 1.34E+02
1.37E+02 1.35E+02
1.25E+02 1.25E+02
1.26E+02 1.26E+02
1.38E+02 1.40E+02
1.43E+02 1.37E+02
1.31E+02 1.30E+02
1.32E+02 1.30E+02
1.24E+02 1.24E+02
1.40E+02 1.38E+02
1.35E+02
8.00E+00
1.57E+02
1.13E+02
1.37E+02
1.26E+01
1.71E+02
1.02E+02
1.33E+02
7.62E+00
1.54E+02
1.12E+02
1.36E+02
1.16E+01
1.67E+02
1.04E+02
1.00E+02
PASS
1.34E+02
7.70E+00
1.55E+02
1.13E+02
1.00E+02
PASS
1.34E+02
7.15E+00
1.53E+02
1.14E+02
9.80E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
57
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio 3 (dB)
@ VS= +/-10V to +/-18V, VCM= 0V
1.60E+02
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.25. Plot of Power Supply Rejection Ratio 3 (dB) @ VS= +/-10V to +/-18V, VCM= 0V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
58
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.25. Raw data for Power Supply Rejection Ratio 3 (dB) @ VS= +/-10V to +/-18V, VCM= 0V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio 3 (dB)
@ VS= +/-10V to +/-18V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.20E+02
1.38E+02
1.56E+02
1.20E+02
1.27E+02
1.32E+02
1.36E+02
1.51E+02
1.24E+02
1.28E+02
1.51E+02
24 Hr
Anneal
60
1.19E+02
1.37E+02
1.56E+02
1.20E+02
1.27E+02
1.33E+02
1.36E+02
1.70E+02
1.24E+02
1.28E+02
1.51E+02
168 Hr
Anneal
70
1.21E+02
1.45E+02
1.39E+02
1.21E+02
1.31E+02
1.29E+02
1.53E+02
1.38E+02
1.28E+02
1.33E+02
1.59E+02
1.31E+02
1.14E+01
1.62E+02
9.94E+01
1.32E+02
1.53E+01
1.74E+02
9.03E+01
1.32E+02
1.52E+01
1.74E+02
9.03E+01
1.31E+02
1.09E+01
1.61E+02
1.01E+02
1.41E+02
2.26E+01
2.03E+02
7.95E+01
9.80E+01
PASS
1.34E+02
1.04E+01
1.63E+02
1.06E+02
9.40E+01
PASS
1.38E+02
1.85E+01
1.89E+02
8.75E+01
9.40E+01
PASS
1.36E+02
1.03E+01
1.64E+02
1.08E+02
9.40E+01
PASS
0
1.21E+02
1.75E+02
1.36E+02
1.22E+02
1.34E+02
1.27E+02
1.39E+02
1.37E+02
1.30E+02
1.45E+02
1.45E+02
Total
10
1.20E+02
1.42E+02
1.39E+02
1.21E+02
1.33E+02
1.28E+02
1.48E+02
1.32E+02
1.27E+02
1.40E+02
1.81E+02
Dose (krad(Si))
20
30
1.21E+02 1.20E+02
1.37E+02 1.36E+02
1.59E+02 1.47E+02
1.21E+02 1.20E+02
1.33E+02 1.30E+02
1.29E+02 1.30E+02
1.51E+02 1.81E+02
1.37E+02 1.39E+02
1.26E+02 1.26E+02
1.38E+02 1.31E+02
1.42E+02 1.43E+02
1.38E+02
2.19E+01
1.98E+02
7.77E+01
1.31E+02
1.02E+01
1.59E+02
1.03E+02
1.34E+02
1.56E+01
1.77E+02
9.15E+01
1.35E+02
7.36E+00
1.55E+02
1.15E+02
1.00E+02
PASS
1.35E+02
8.70E+00
1.59E+02
1.11E+02
1.00E+02
PASS
1.36E+02
9.47E+00
1.62E+02
1.10E+02
9.80E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
59
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio 4 (dB)
@ VS= +/-10V to +/-18V, VCM= 0V
1.60E+02
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.26. Plot of Power Supply Rejection Ratio 4 (dB) @ VS= +/-10V to +/-18V, VCM= 0V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
60
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.26. Raw data for Power Supply Rejection Ratio 4 (dB) @ VS= +/-10V to +/-18V, VCM= 0V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio 4 (dB)
@ VS= +/-10V to +/-18V, VCM= 0V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.32E+02
1.37E+02
1.31E+02
1.55E+02
1.37E+02
1.32E+02
1.43E+02
1.30E+02
1.25E+02
1.39E+02
1.29E+02
24 Hr
Anneal
60
1.32E+02
1.37E+02
1.31E+02
1.55E+02
1.37E+02
1.32E+02
1.40E+02
1.29E+02
1.25E+02
1.39E+02
1.30E+02
168 Hr
Anneal
70
1.39E+02
1.31E+02
1.38E+02
1.41E+02
1.92E+02
1.28E+02
1.40E+02
1.35E+02
1.30E+02
1.38E+02
1.29E+02
1.38E+02
9.26E+00
1.63E+02
1.12E+02
1.38E+02
9.82E+00
1.65E+02
1.12E+02
1.38E+02
1.00E+01
1.66E+02
1.11E+02
1.48E+02
2.50E+01
2.17E+02
7.96E+01
1.39E+02
1.30E+01
1.75E+02
1.03E+02
9.80E+01
PASS
1.34E+02
7.24E+00
1.54E+02
1.14E+02
9.40E+01
PASS
1.33E+02
6.58E+00
1.51E+02
1.15E+02
9.40E+01
PASS
1.34E+02
5.42E+00
1.49E+02
1.19E+02
9.40E+01
PASS
0
1.41E+02
1.30E+02
1.53E+02
1.31E+02
1.62E+02
1.27E+02
1.33E+02
1.49E+02
1.34E+02
1.34E+02
1.30E+02
Total
10
1.38E+02
1.31E+02
1.41E+02
1.37E+02
1.54E+02
1.28E+02
1.34E+02
1.34E+02
1.33E+02
1.36E+02
1.28E+02
Dose (krad(Si))
20
30
1.33E+02 1.31E+02
1.32E+02 1.34E+02
1.36E+02 1.33E+02
1.53E+02 1.54E+02
1.35E+02 1.36E+02
1.28E+02 1.30E+02
1.37E+02 1.54E+02
1.34E+02 1.31E+02
1.29E+02 1.28E+02
1.61E+02 1.53E+02
1.32E+02 1.31E+02
1.43E+02
1.38E+01
1.81E+02
1.05E+02
1.40E+02
8.56E+00
1.64E+02
1.17E+02
1.38E+02
8.69E+00
1.62E+02
1.14E+02
1.35E+02
8.14E+00
1.58E+02
1.13E+02
1.00E+02
PASS
1.33E+02
2.89E+00
1.41E+02
1.25E+02
1.00E+02
PASS
1.38E+02
1.33E+01
1.74E+02
1.01E+02
9.80E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
61
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Open Loop Gain 1 (V/mV)
@ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
8.00E+03
6.00E+03
4.00E+03
2.00E+03
0.00E+00
-2.00E+03
-4.00E+03
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.27. Plot of Open Loop Gain 1 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
62
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.27. Raw data for Open Loop Gain 1 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Open Loop Gain 1 (V/mV)
@ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
2.83E+03
3.74E+03
3.22E+03
2.12E+03
3.63E+03
5.22E+03
5.89E+03
5.69E+03
2.77E+03
2.63E+03
6.90E+03
24 Hr
Anneal
60
2.75E+03
3.81E+03
3.30E+03
2.22E+03
3.48E+03
5.93E+03
5.67E+03
5.68E+03
3.11E+03
2.90E+03
7.46E+03
168 Hr
Anneal
70
2.60E+03
3.38E+03
2.84E+03
1.95E+03
3.29E+03
5.84E+03
6.73E+03
6.17E+03
3.05E+03
3.01E+03
7.53E+03
2.59E+03
6.73E+02
4.43E+03
7.43E+02
3.10E+03
6.61E+02
4.92E+03
1.29E+03
3.11E+03
6.31E+02
4.84E+03
1.38E+03
2.81E+03
5.79E+02
4.40E+03
1.22E+03
2.91E+03
9.65E+02
5.55E+03
2.63E+02
2.00E+02
PASS
4.44E+03
1.61E+03
8.85E+03
2.89E+01
1.00E+02
PASS
4.65E+03
1.51E+03
8.81E+03
5.03E+02
1.00E+02
PASS
4.96E+03
1.79E+03
9.86E+03
5.53E+01
1.00E+02
PASS
0
5.14E+03
9.77E+03
6.99E+03
2.99E+03
8.14E+03
9.94E+03
8.26E+03
9.78E+03
3.10E+03
3.16E+03
3.71E+03
Total
10
3.92E+03
6.32E+03
4.71E+03
2.72E+03
5.92E+03
6.08E+03
7.52E+03
6.61E+03
2.68E+03
2.38E+03
3.71E+03
Dose (krad(Si))
20
30
2.85E+03 2.31E+03
4.52E+03 3.32E+03
3.48E+03 2.75E+03
1.88E+03 1.58E+03
4.38E+03 2.98E+03
4.72E+03 3.57E+03
5.71E+03 3.21E+03
4.83E+03 3.96E+03
2.26E+03 2.00E+03
2.20E+03 1.79E+03
3.47E+03 3.70E+03
6.60E+03
2.63E+03
1.38E+04
-6.14E+02
4.72E+03
1.47E+03
8.75E+03
6.88E+02
3.42E+03
1.10E+03
6.44E+03
4.05E+02
6.85E+03
3.46E+03
1.63E+04
-2.63E+03
1.20E+03
PASS
5.05E+03
2.37E+03
1.15E+04
-1.43E+03
5.00E+02
PASS
3.94E+03
1.61E+03
8.36E+03
-4.75E+02
2.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
63
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Open Loop Gain 2 (V/mV)
@ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
5.00E+03
4.00E+03
3.00E+03
2.00E+03
1.00E+03
0.00E+00
-1.00E+03
-2.00E+03
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.28. Plot of Open Loop Gain 2 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
64
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.28. Raw data for Open Loop Gain 2 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Open Loop Gain 2 (V/mV)
@ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
2.16E+03
3.18E+03
2.22E+03
2.09E+03
3.00E+03
4.67E+03
3.32E+03
3.58E+03
3.03E+03
3.52E+03
6.48E+03
24 Hr
Anneal
60
2.03E+03
3.19E+03
2.19E+03
2.01E+03
3.08E+03
4.36E+03
3.95E+03
4.09E+03
2.92E+03
3.67E+03
6.17E+03
168 Hr
Anneal
70
1.81E+03
2.89E+03
1.94E+03
1.85E+03
2.78E+03
4.99E+03
4.32E+03
4.39E+03
2.92E+03
3.93E+03
6.01E+03
1.99E+03
5.49E+02
3.49E+03
4.85E+02
2.53E+03
5.17E+02
3.95E+03
1.11E+03
2.50E+03
5.84E+02
4.10E+03
8.99E+02
2.25E+03
5.34E+02
3.72E+03
7.88E+02
2.69E+03
5.17E+02
4.11E+03
1.27E+03
2.00E+02
PASS
3.62E+03
6.25E+02
5.33E+03
1.91E+03
1.00E+02
PASS
3.80E+03
5.52E+02
5.31E+03
2.29E+03
1.00E+02
PASS
4.11E+03
7.64E+02
6.21E+03
2.01E+03
1.00E+02
PASS
0
2.92E+03
7.22E+03
3.34E+03
3.17E+03
5.69E+03
5.98E+03
4.72E+03
5.01E+03
3.26E+03
4.62E+03
3.41E+03
Total
10
2.24E+03
4.54E+03
2.66E+03
2.41E+03
4.17E+03
5.23E+03
3.73E+03
4.08E+03
2.71E+03
3.39E+03
3.20E+03
Dose (krad(Si))
20
30
1.81E+03 1.48E+03
3.22E+03 2.72E+03
2.10E+03 1.72E+03
1.92E+03 1.60E+03
3.11E+03 2.43E+03
3.84E+03 3.34E+03
3.05E+03 2.61E+03
3.66E+03 3.05E+03
2.20E+03 2.04E+03
2.93E+03 2.40E+03
3.15E+03 3.15E+03
4.47E+03
1.90E+03
9.68E+03
-7.46E+02
3.20E+03
1.07E+03
6.14E+03
2.73E+02
2.43E+03
6.80E+02
4.30E+03
5.69E+02
4.72E+03
9.78E+02
7.40E+03
2.03E+03
1.20E+03
PASS
3.83E+03
9.35E+02
6.39E+03
1.26E+03
5.00E+02
PASS
3.13E+03
6.51E+02
4.92E+03
1.35E+03
2.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
65
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Open Loop Gain 3 (V/mV)
@ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
8.00E+03
6.00E+03
4.00E+03
2.00E+03
0.00E+00
-2.00E+03
-4.00E+03
-6.00E+03
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.29. Plot of Open Loop Gain 3 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
66
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.29. Raw data for Open Loop Gain 3 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Open Loop Gain 3 (V/mV)
@ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
3.87E+03
1.19E+04
3.24E+03
3.99E+03
6.21E+03
7.62E+03
5.75E+03
6.53E+03
4.09E+03
5.19E+03
3.18E+03
Total
10
3.11E+03
6.00E+03
2.61E+03
2.94E+03
4.60E+03
4.83E+03
4.26E+03
6.54E+03
3.12E+03
4.50E+03
3.19E+03
Dose (krad(Si))
20
30
2.24E+03 1.66E+03
4.19E+03 3.26E+03
2.23E+03 1.75E+03
2.21E+03 1.86E+03
3.57E+03 2.83E+03
4.68E+03 3.93E+03
3.31E+03 2.97E+03
4.55E+03 4.06E+03
2.58E+03 2.63E+03
3.58E+03 2.81E+03
3.15E+03 3.24E+03
50
2.25E+03
3.73E+03
2.43E+03
2.38E+03
3.41E+03
4.85E+03
4.17E+03
4.74E+03
3.15E+03
3.90E+03
6.11E+03
24 Hr
Anneal
60
2.31E+03
3.58E+03
2.40E+03
2.31E+03
3.30E+03
5.43E+03
4.04E+03
5.21E+03
3.61E+03
4.47E+03
6.50E+03
168 Hr
Anneal
70
2.05E+03
3.61E+03
2.15E+03
2.08E+03
2.95E+03
5.96E+03
4.67E+03
5.54E+03
3.47E+03
4.15E+03
6.00E+03
5.85E+03
3.58E+03
1.56E+04
-3.96E+03
3.85E+03
1.42E+03
7.76E+03
-5.38E+01
2.89E+03
9.30E+02
5.44E+03
3.35E+02
2.27E+03
7.25E+02
4.26E+03
2.83E+02
2.84E+03
6.78E+02
4.70E+03
9.79E+02
2.78E+03
6.11E+02
4.46E+03
1.11E+03
2.57E+03
6.90E+02
4.46E+03
6.77E+02
5.84E+03
1.33E+03
9.49E+03
2.18E+03
1.20E+03
PASS
4.65E+03
1.24E+03
8.04E+03
1.26E+03
5.00E+02
PASS
3.74E+03
8.79E+02
6.15E+03
1.33E+03
2.00E+02
PASS
3.28E+03
6.66E+02
5.11E+03
1.45E+03
2.00E+02
PASS
4.16E+03
6.90E+02
6.05E+03
2.27E+03
1.00E+02
PASS
4.55E+03
7.67E+02
6.66E+03
2.45E+03
1.00E+02
PASS
4.76E+03
1.01E+03
7.53E+03
1.98E+03
1.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
67
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Open Loop Gain 4 (V/mV)
@ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
8.00E+03
6.00E+03
4.00E+03
2.00E+03
0.00E+00
-2.00E+03
-4.00E+03
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.30. Plot of Open Loop Gain 4 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
68
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.30. Raw data for Open Loop Gain 4 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Open Loop Gain 4 (V/mV)
@ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
2.75E+03
3.49E+03
2.71E+03
2.04E+03
2.81E+03
5.60E+03
5.32E+03
5.02E+03
2.79E+03
2.64E+03
6.29E+03
24 Hr
Anneal
60
2.72E+03
3.55E+03
2.74E+03
2.07E+03
3.04E+03
4.99E+03
4.92E+03
5.00E+03
2.85E+03
2.63E+03
6.91E+03
168 Hr
Anneal
70
2.37E+03
3.18E+03
2.43E+03
1.90E+03
2.88E+03
6.06E+03
5.67E+03
5.55E+03
3.24E+03
2.74E+03
6.81E+03
2.16E+03
5.13E+02
3.57E+03
7.57E+02
2.76E+03
5.15E+02
4.17E+03
1.35E+03
2.82E+03
5.38E+02
4.30E+03
1.35E+03
2.55E+03
4.94E+02
3.90E+03
1.20E+03
3.19E+03
1.14E+03
6.32E+03
5.82E+01
2.00E+02
PASS
4.27E+03
1.44E+03
8.22E+03
3.26E+02
1.00E+02
PASS
4.08E+03
1.22E+03
7.43E+03
7.25E+02
1.00E+02
PASS
4.65E+03
1.54E+03
8.87E+03
4.29E+02
1.00E+02
PASS
0
4.43E+03
8.45E+03
4.13E+03
2.88E+03
4.69E+03
1.13E+04
7.14E+03
8.48E+03
3.34E+03
2.86E+03
3.31E+03
Total
10
3.16E+03
5.63E+03
3.05E+03
2.32E+03
3.83E+03
7.28E+03
6.12E+03
7.92E+03
2.58E+03
2.22E+03
3.35E+03
Dose (krad(Si))
20
30
2.56E+03 1.97E+03
3.84E+03 2.89E+03
2.67E+03 2.13E+03
1.93E+03 1.49E+03
2.83E+03 2.34E+03
5.50E+03 4.58E+03
4.80E+03 3.49E+03
4.55E+03 3.83E+03
2.28E+03 2.18E+03
2.25E+03 1.86E+03
3.10E+03 3.52E+03
4.92E+03
2.09E+03
1.07E+04
-8.24E+02
3.60E+03
1.25E+03
7.04E+03
1.62E+02
2.77E+03
6.92E+02
4.66E+03
8.68E+02
6.61E+03
3.54E+03
1.63E+04
-3.09E+03
1.20E+03
PASS
5.22E+03
2.66E+03
1.25E+04
-2.08E+03
5.00E+02
PASS
3.87E+03
1.51E+03
8.02E+03
-2.67E+02
2.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
69
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.42E+01
Positive Output Voltage 15V 1 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
1.40E+01
1.38E+01
1.36E+01
1.34E+01
1.32E+01
1.30E+01
1.28E+01
1.26E+01
1.24E+01
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.31. Plot of Positive Output Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
70
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.31. Raw data for Positive Output Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 15V 1 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Total
10
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Dose (krad(Si))
20
30
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
50
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
24 Hr
Anneal
60
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
168 Hr
Anneal
70
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
5.57E-03 3.71E-03 4.24E-03 4.67E-03 4.39E-03 4.39E-03 4.72E-03
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
1.41E+01
6.07E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.78E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.38E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.76E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.54E-03
1.41E+01
1.41E+01
1.25E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
71
1.41E+01
6.61E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.27E-03
1.41E+01
1.41E+01
1.25E+01
PASS
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.42E+01
Positive Output Voltage 15V 2 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
1.40E+01
1.38E+01
1.36E+01
1.34E+01
1.32E+01
1.30E+01
1.28E+01
1.26E+01
1.24E+01
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.32. Plot of Positive Output Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
72
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.32. Raw data for Positive Output Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 15V 2 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Total
10
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Dose (krad(Si))
20
30
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
50
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
24 Hr
Anneal
60
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
168 Hr
Anneal
70
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
6.00E-03 4.98E-03 4.98E-03 5.15E-03 5.22E-03 4.98E-03 4.64E-03
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
1.41E+01
5.15E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
4.87E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
4.72E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
4.60E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
4.93E-03
1.41E+01
1.41E+01
1.25E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
73
1.41E+01
4.44E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
4.98E-03
1.41E+01
1.41E+01
1.25E+01
PASS
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.42E+01
Positive Output Voltage 15V 3 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
1.40E+01
1.38E+01
1.36E+01
1.34E+01
1.32E+01
1.30E+01
1.28E+01
1.26E+01
1.24E+01
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.33. Plot of Positive Output Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
74
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.33. Raw data for Positive Output Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 15V 3 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Total
10
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Dose (krad(Si))
20
30
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
50
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
24 Hr
Anneal
60
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
168 Hr
Anneal
70
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
6.26E-03 5.10E-03 5.03E-03 5.77E-03 5.10E-03 5.40E-03 5.24E-03
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
1.41E+01
5.50E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.22E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.55E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.59E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.02E-03
1.41E+01
1.41E+01
1.25E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
75
1.41E+01
4.92E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.32E-03
1.41E+01
1.41E+01
1.25E+01
PASS
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.42E+01
Positive Output Voltage 15V 4 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
1.40E+01
1.38E+01
1.36E+01
1.34E+01
1.32E+01
1.30E+01
1.28E+01
1.26E+01
1.24E+01
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.34. Plot of Positive Output Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
76
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.34. Raw data for Positive Output Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 15V 4 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Total
10
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Dose (krad(Si))
20
30
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
50
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
24 Hr
Anneal
60
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
168 Hr
Anneal
70
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
5.55E-03 3.85E-03 4.02E-03 4.24E-03 4.22E-03 3.77E-03 4.10E-03
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
1.41E+01
6.46E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.24E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.93E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.30E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.98E-03
1.41E+01
1.41E+01
1.25E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
77
1.41E+01
5.97E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.07E-03
1.41E+01
1.41E+01
1.25E+01
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Negative Output Voltage 15V 1 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
-1.20E+01
-1.25E+01
-1.30E+01
-1.35E+01
-1.40E+01
-1.45E+01
-1.50E+01
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.35. Plot of Negative Output Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
78
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.35. Raw data for Negative Output Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Output Voltage 15V 1 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
Total Dose (krad(Si))
10
20
30
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
50
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
24 Hr
Anneal
60
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
168 Hr
Anneal
70
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
3.44E-03 3.63E-03 3.58E-03 3.85E-03 3.97E-03 4.22E-03 3.97E-03
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01
3.77E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
3.83E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
4.27E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
3.83E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
3.77E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
79
-1.44E+01
3.77E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
4.56E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Negative Output Voltage 15V 2 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
-1.20E+01
-1.25E+01
-1.30E+01
-1.35E+01
-1.40E+01
-1.45E+01
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.36. Plot of Negative Output Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
80
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.36. Raw data for Negative Output Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Output Voltage 15V 2 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
Total Dose (krad(Si))
10
20
30
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
50
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
24 Hr
Anneal
60
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
168 Hr
Anneal
70
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
4.45E-03 4.10E-03 3.90E-03 3.85E-03 4.34E-03 4.10E-03 4.38E-03
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01
1.67E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
8.94E-04
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
1.41E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
1.52E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
1.67E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
81
-1.44E+01
1.48E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
1.48E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Negative Output Voltage 15V 3 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
-1.20E+01
-1.25E+01
-1.30E+01
-1.35E+01
-1.40E+01
-1.45E+01
-1.50E+01
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.37. Plot of Negative Output Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
82
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.37. Raw data for Negative Output Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Output Voltage 15V 3 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
Total Dose (krad(Si))
10
20
30
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
50
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
24 Hr
Anneal
60
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
168 Hr
Anneal
70
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
4.28E-03 3.91E-03 3.61E-03 3.74E-03 3.78E-03 4.02E-03 3.74E-03
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01
1.34E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
8.94E-04
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
1.14E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
8.94E-04
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
1.00E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
83
-1.44E+01
1.34E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
1.41E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Negative Output Voltage 15V 4 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
-1.20E+01
-1.25E+01
-1.30E+01
-1.35E+01
-1.40E+01
-1.45E+01
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.38. Plot of Negative Output Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
84
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.38. Raw data for Negative Output Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V, RL= 10K versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Output Voltage 15V 4 (V)
@ VS= +/-15V, VCM= 0V, RL= 10K
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
Total Dose (krad(Si))
10
20
30
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01
50
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
24 Hr
Anneal
60
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
168 Hr
Anneal
70
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
3.90E-03 4.22E-03 4.15E-03 3.91E-03 4.44E-03 4.55E-03 3.96E-03
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01
-1.44E+01
4.00E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
4.56E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
4.56E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
4.60E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
4.60E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
85
-1.44E+01
5.02E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
-1.44E+01
4.80E-03
-1.44E+01
-1.44E+01
-1.25E+01
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
Positive Slew Rate 1 (V/us) @ VS= +/-15V
5.00E-01
4.50E-01
4.00E-01
3.50E-01
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.39. Plot of Positive Slew Rate 1 (V/us) @ VS= +/-15V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
86
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.39. Raw data for Positive Slew Rate 1 (V/us) @ VS= +/-15V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Positive Slew Rate 1 (V/us)
@ VS= +/-15V
Device
59
149
233
310
393
443
516
574
589
732
829
0
4.57E-01
4.74E-01
4.64E-01
4.42E-01
4.92E-01
4.61E-01
4.66E-01
4.70E-01
4.35E-01
4.45E-01
4.45E-01
Total
10
4.48E-01
4.59E-01
4.68E-01
4.44E-01
4.58E-01
4.59E-01
4.69E-01
4.72E-01
4.36E-01
4.48E-01
4.45E-01
Dose (krad(Si))
20
30
4.44E-01 4.35E-01
4.61E-01 4.54E-01
4.55E-01 4.51E-01
4.30E-01 4.20E-01
4.57E-01 4.57E-01
4.67E-01 4.53E-01
4.57E-01 4.59E-01
4.58E-01 4.57E-01
4.24E-01 4.20E-01
4.32E-01 4.29E-01
4.39E-01 4.32E-01
50
4.17E-01
4.28E-01
4.29E-01
4.00E-01
4.36E-01
4.30E-01
4.42E-01
4.34E-01
4.02E-01
4.14E-01
4.37E-01
24 Hr
Anneal
60
4.20E-01
4.29E-01
4.28E-01
4.06E-01
4.33E-01
4.43E-01
4.40E-01
4.41E-01
4.05E-01
4.22E-01
4.42E-01
168 Hr
Anneal
70
4.14E-01
4.23E-01
4.33E-01
4.02E-01
4.38E-01
4.37E-01
4.54E-01
4.42E-01
4.18E-01
4.24E-01
4.47E-01
Biased Statistics
Average Biased
4.66E-01 4.55E-01 4.49E-01 4.43E-01 4.22E-01 4.23E-01 4.22E-01
Std Dev Biased
1.87E-02 9.53E-03 1.25E-02 1.56E-02 1.41E-02 1.07E-02 1.45E-02
Ps90%/90% (+KTL) Biased
5.17E-01 4.82E-01 4.84E-01 4.86E-01 4.61E-01 4.53E-01 4.62E-01
Ps90%/90% (-KTL) Biased
4.14E-01 4.29E-01 4.15E-01 4.01E-01 3.83E-01 3.94E-01 3.82E-01
Un-Biased Statistics
Average Un-Biased
4.55E-01 4.57E-01 4.48E-01 4.44E-01 4.24E-01 4.30E-01 4.35E-01
Std Dev Un-Biased
1.48E-02 1.50E-02 1.85E-02 1.79E-02 1.61E-02 1.64E-02 1.44E-02
Ps90%/90% (+KTL) Un-Biased
4.96E-01 4.98E-01 4.98E-01 4.93E-01 4.69E-01 4.75E-01 4.74E-01
Ps90%/90% (-KTL) Un-Biased
4.15E-01 4.16E-01 3.97E-01 3.95E-01 3.80E-01 3.85E-01 3.96E-01
Specification MIN
2.00E-01 1.30E-01 1.20E-01 1.20E-01 1.10E-01 1.10E-01 1.10E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
87
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
Positive Slew Rate 2 (V/us) @ VS= +/-15V
5.00E-01
4.50E-01
4.00E-01
3.50E-01
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.40. Plot of Positive Slew Rate 2 (V/us) @ VS= +/-15V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
88
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.40. Raw data for Positive Slew Rate 2 (V/us) @ VS= +/-15V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Positive Slew Rate 2 (V/us)
@ VS= +/-15V
Device
59
149
233
310
393
443
516
574
589
732
829
0
4.14E-01
4.39E-01
4.53E-01
4.08E-01
4.46E-01
4.46E-01
4.22E-01
4.24E-01
4.22E-01
4.27E-01
4.24E-01
Total
10
4.04E-01
4.21E-01
4.23E-01
4.00E-01
4.40E-01
4.45E-01
4.29E-01
4.23E-01
4.14E-01
4.21E-01
4.23E-01
Dose (krad(Si))
20
30
4.05E-01 3.89E-01
4.20E-01 4.17E-01
4.27E-01 4.17E-01
3.86E-01 3.94E-01
4.33E-01 4.29E-01
4.31E-01 4.22E-01
4.19E-01 4.14E-01
4.23E-01 4.21E-01
4.08E-01 3.98E-01
4.10E-01 4.08E-01
4.20E-01 4.23E-01
50
3.78E-01
3.98E-01
3.97E-01
3.73E-01
4.11E-01
4.09E-01
3.91E-01
4.03E-01
3.84E-01
3.90E-01
4.20E-01
24 Hr
Anneal
60
3.82E-01
3.99E-01
3.98E-01
3.70E-01
4.14E-01
4.09E-01
3.97E-01
4.05E-01
3.86E-01
3.94E-01
4.28E-01
168 Hr
Anneal
70
3.76E-01
4.03E-01
3.96E-01
3.68E-01
4.11E-01
4.24E-01
4.10E-01
4.14E-01
3.96E-01
4.06E-01
4.22E-01
Biased Statistics
Average Biased
4.32E-01 4.18E-01 4.14E-01 4.09E-01 3.91E-01 3.93E-01 3.91E-01
Std Dev Biased
1.99E-02 1.61E-02 1.89E-02 1.70E-02 1.56E-02 1.70E-02 1.82E-02
Ps90%/90% (+KTL) Biased
4.87E-01 4.62E-01 4.66E-01 4.56E-01 4.34E-01 4.39E-01 4.41E-01
Ps90%/90% (-KTL) Biased
3.77E-01 3.73E-01 3.62E-01 3.63E-01 3.49E-01 3.46E-01 3.41E-01
Un-Biased Statistics
Average Un-Biased
4.28E-01 4.26E-01 4.18E-01 4.13E-01 3.95E-01 3.98E-01 4.10E-01
Std Dev Un-Biased
1.02E-02 1.17E-02 9.47E-03 9.94E-03 1.03E-02 9.09E-03 1.03E-02
Ps90%/90% (+KTL) Un-Biased
4.56E-01 4.58E-01 4.44E-01 4.40E-01 4.24E-01 4.23E-01 4.38E-01
Ps90%/90% (-KTL) Un-Biased
4.00E-01 3.94E-01 3.92E-01 3.85E-01 3.67E-01 3.73E-01 3.82E-01
Specification MIN
2.00E-01 1.30E-01 1.20E-01 1.20E-01 1.10E-01 1.10E-01 1.10E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
89
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
Positive Slew Rate 3 (V/us) @ VS= +/-15V
5.00E-01
4.50E-01
4.00E-01
3.50E-01
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.41. Plot of Positive Slew Rate 3 (V/us) @ VS= +/-15V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
90
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.41. Raw data for Positive Slew Rate 3 (V/us) @ VS= +/-15V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Positive Slew Rate 3 (V/us)
@ VS= +/-15V
Device
59
149
233
310
393
443
516
574
589
732
829
0
4.33E-01
4.66E-01
4.62E-01
4.38E-01
4.70E-01
4.69E-01
4.47E-01
4.57E-01
4.39E-01
4.49E-01
4.45E-01
Total
10
4.26E-01
4.52E-01
4.64E-01
4.23E-01
4.53E-01
4.56E-01
4.53E-01
4.60E-01
4.40E-01
4.46E-01
4.46E-01
Dose (krad(Si))
20
30
4.27E-01 4.22E-01
4.44E-01 4.39E-01
4.52E-01 4.46E-01
4.19E-01 4.18E-01
4.65E-01 4.58E-01
4.56E-01 4.41E-01
4.44E-01 4.32E-01
4.48E-01 4.46E-01
4.32E-01 4.26E-01
4.45E-01 4.38E-01
4.45E-01 4.49E-01
50
3.99E-01
4.15E-01
4.18E-01
3.94E-01
4.35E-01
4.31E-01
4.18E-01
4.34E-01
4.06E-01
4.19E-01
4.46E-01
24 Hr
Anneal
60
4.05E-01
4.25E-01
4.30E-01
4.00E-01
4.27E-01
4.41E-01
4.19E-01
4.31E-01
4.09E-01
4.23E-01
4.48E-01
168 Hr
Anneal
70
4.06E-01
4.20E-01
4.25E-01
3.98E-01
4.37E-01
4.46E-01
4.33E-01
4.42E-01
4.22E-01
4.30E-01
4.45E-01
Biased Statistics
Average Biased
4.54E-01 4.44E-01 4.41E-01 4.37E-01 4.12E-01 4.17E-01 4.17E-01
Std Dev Biased
1.70E-02 1.81E-02 1.86E-02 1.67E-02 1.63E-02 1.38E-02 1.54E-02
Ps90%/90% (+KTL) Biased
5.01E-01 4.93E-01 4.92E-01 4.82E-01 4.57E-01 4.55E-01 4.60E-01
Ps90%/90% (-KTL) Biased
4.07E-01 3.94E-01 3.90E-01 3.91E-01 3.67E-01 3.79E-01 3.75E-01
Un-Biased Statistics
Average Un-Biased
4.52E-01 4.51E-01 4.45E-01 4.37E-01 4.22E-01 4.25E-01 4.35E-01
Std Dev Un-Biased
1.14E-02 8.00E-03 8.66E-03 7.80E-03 1.12E-02 1.21E-02 9.58E-03
Ps90%/90% (+KTL) Un-Biased
4.83E-01 4.73E-01 4.69E-01 4.58E-01 4.52E-01 4.58E-01 4.61E-01
Ps90%/90% (-KTL) Un-Biased
4.21E-01 4.29E-01 4.21E-01 4.15E-01 3.91E-01 3.91E-01 4.08E-01
Specification MIN
2.00E-01 1.30E-01 1.20E-01 1.20E-01 1.10E-01 1.10E-01 1.10E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
91
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
Positive Slew Rate 4 (V/us) @ VS= +/-15V
5.00E-01
4.50E-01
4.00E-01
3.50E-01
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.42. Plot of Positive Slew Rate 4 (V/us) @ VS= +/-15V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
92
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.42. Raw data for Positive Slew Rate 4 (V/us) @ VS= +/-15V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Positive Slew Rate 4 (V/us)
@ VS= +/-15V
Device
59
149
233
310
393
443
516
574
589
732
829
0
4.38E-01
4.41E-01
4.50E-01
4.23E-01
4.46E-01
4.42E-01
4.47E-01
4.34E-01
4.20E-01
4.23E-01
4.24E-01
Total
10
4.28E-01
4.28E-01
4.35E-01
4.07E-01
4.37E-01
4.31E-01
4.45E-01
4.46E-01
4.02E-01
4.18E-01
4.21E-01
Dose (krad(Si))
20
30
4.22E-01 4.16E-01
4.27E-01 4.23E-01
4.27E-01 4.26E-01
4.05E-01 3.97E-01
4.37E-01 4.29E-01
4.29E-01 4.25E-01
4.33E-01 4.24E-01
4.34E-01 4.27E-01
3.99E-01 3.87E-01
4.09E-01 4.08E-01
4.14E-01 4.22E-01
50
3.97E-01
4.01E-01
4.08E-01
3.78E-01
4.16E-01
4.07E-01
4.13E-01
4.12E-01
3.83E-01
3.87E-01
4.19E-01
24 Hr
Anneal
60
4.05E-01
4.01E-01
4.10E-01
3.86E-01
4.11E-01
4.10E-01
4.11E-01
4.08E-01
3.80E-01
3.90E-01
4.22E-01
168 Hr
Anneal
70
4.02E-01
4.08E-01
4.06E-01
3.80E-01
4.07E-01
4.22E-01
4.30E-01
4.22E-01
3.87E-01
4.01E-01
4.22E-01
Biased Statistics
Average Biased
4.40E-01 4.27E-01 4.24E-01 4.18E-01 4.00E-01 4.03E-01 4.01E-01
Std Dev Biased
1.04E-02 1.19E-02 1.17E-02 1.28E-02 1.43E-02 1.01E-02 1.17E-02
Ps90%/90% (+KTL) Biased
4.68E-01 4.60E-01 4.56E-01 4.53E-01 4.39E-01 4.30E-01 4.33E-01
Ps90%/90% (-KTL) Biased
4.11E-01 3.94E-01 3.91E-01 3.83E-01 3.61E-01 3.75E-01 3.68E-01
Un-Biased Statistics
Average Un-Biased
4.33E-01 4.28E-01 4.21E-01 4.14E-01 4.00E-01 4.00E-01 4.12E-01
Std Dev Un-Biased
1.17E-02 1.87E-02 1.58E-02 1.70E-02 1.43E-02 1.40E-02 1.78E-02
Ps90%/90% (+KTL) Un-Biased
4.65E-01 4.80E-01 4.64E-01 4.61E-01 4.40E-01 4.38E-01 4.61E-01
Ps90%/90% (-KTL) Un-Biased
4.01E-01 3.77E-01 3.77E-01 3.68E-01 3.61E-01 3.61E-01 3.64E-01
Specification MIN
2.00E-01 1.30E-01 1.20E-01 1.20E-01 1.10E-01 1.10E-01 1.10E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
93
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Ps90%/90% (+KTL) Biased
Negative Slew Rate 1 (V/us) @ VS= +/-15V
2.00E-01
1.00E-01
0.00E+00
-1.00E-01
-2.00E-01
-3.00E-01
-4.00E-01
-5.00E-01
-6.00E-01
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.43. Plot of Negative Slew Rate 1 (V/us) @ VS= +/-15V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
94
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.43. Raw data for Negative Slew Rate 1 (V/us) @ VS= +/-15V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Negative Slew Rate 1 (V/us)
@ VS= +/-15V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-5.13E-01
-5.11E-01
-5.27E-01
-4.74E-01
-5.37E-01
-5.13E-01
-5.34E-01
-5.10E-01
-4.71E-01
-4.92E-01
-4.92E-01
Total
10
-5.04E-01
-4.96E-01
-4.99E-01
-4.78E-01
-5.20E-01
-5.03E-01
-5.18E-01
-5.38E-01
-4.84E-01
-4.80E-01
-4.87E-01
Dose (krad(Si))
20
30
-4.97E-01 -4.86E-01
-5.03E-01 -4.97E-01
-5.04E-01 -4.91E-01
-4.68E-01 -4.72E-01
-5.21E-01 -5.05E-01
-5.06E-01 -4.90E-01
-5.02E-01 -4.91E-01
-5.27E-01 -5.03E-01
-4.68E-01 -4.73E-01
-4.74E-01 -4.70E-01
-4.89E-01 -4.95E-01
50
-4.62E-01
-4.74E-01
-4.82E-01
-4.42E-01
-4.79E-01
-4.68E-01
-4.98E-01
-4.88E-01
-4.53E-01
-4.56E-01
-4.85E-01
24 Hr
Anneal
60
-4.65E-01
-4.82E-01
-4.81E-01
-4.56E-01
-4.74E-01
-4.75E-01
-4.86E-01
-4.90E-01
-4.44E-01
-4.62E-01
-4.87E-01
168 Hr
Anneal
70
-4.62E-01
-4.75E-01
-4.79E-01
-4.44E-01
-4.85E-01
-4.98E-01
-4.97E-01
-5.04E-01
-4.47E-01
-4.73E-01
-4.83E-01
-5.12E-01 -4.99E-01 -4.99E-01 -4.90E-01 -4.68E-01 -4.72E-01 -4.69E-01
2.40E-02 1.51E-02 1.93E-02 1.24E-02 1.63E-02 1.11E-02 1.63E-02
-4.47E-01 -4.58E-01 -4.46E-01 -4.56E-01 -4.23E-01 -4.41E-01 -4.24E-01
-5.78E-01 -5.41E-01 -5.52E-01 -5.24E-01 -5.13E-01 -5.02E-01 -5.14E-01
-5.04E-01
2.37E-02
-4.39E-01
-5.69E-01
-2.00E-01
PASS
-5.05E-01
2.41E-02
-4.38E-01
-5.71E-01
1.30E-01
PASS
-4.95E-01
2.43E-02
-4.29E-01
-5.62E-01
1.20E-01
PASS
-4.85E-01
1.37E-02
-4.48E-01
-5.23E-01
1.20E-01
PASS
-4.73E-01
1.98E-02
-4.18E-01
-5.27E-01
1.10E-01
PASS
An ISO 9001:2008 and DSCC Certified Company
95
-4.71E-01
1.88E-02
-4.20E-01
-5.23E-01
1.10E-01
PASS
-4.84E-01
2.37E-02
-4.19E-01
-5.49E-01
1.10E-01
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Ps90%/90% (+KTL) Biased
Negative Slew Rate 2 (V/us) @ VS= +/-15V
2.00E-01
1.00E-01
0.00E+00
-1.00E-01
-2.00E-01
-3.00E-01
-4.00E-01
-5.00E-01
-6.00E-01
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.44. Plot of Negative Slew Rate 2 (V/us) @ VS= +/-15V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
96
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.44. Raw data for Negative Slew Rate 2 (V/us) @ VS= +/-15V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Negative Slew Rate 2 (V/us)
@ VS= +/-15V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-4.57E-01
-4.90E-01
-4.90E-01
-4.44E-01
-5.03E-01
-4.90E-01
-4.56E-01
-4.61E-01
-4.48E-01
-4.64E-01
-4.71E-01
Total
10
-4.39E-01
-4.74E-01
-4.70E-01
-4.35E-01
-4.97E-01
-4.85E-01
-4.74E-01
-4.80E-01
-4.54E-01
-4.71E-01
-4.63E-01
Dose (krad(Si))
20
30
-4.43E-01 -4.37E-01
-4.59E-01 -4.65E-01
-4.69E-01 -4.72E-01
-4.28E-01 -4.32E-01
-4.80E-01 -4.75E-01
-4.77E-01 -4.60E-01
-4.62E-01 -4.53E-01
-4.63E-01 -4.59E-01
-4.47E-01 -4.45E-01
-4.57E-01 -4.53E-01
-4.71E-01 -4.68E-01
50
-4.14E-01
-4.40E-01
-4.45E-01
-4.07E-01
-4.52E-01
-4.55E-01
-4.37E-01
-4.44E-01
-4.26E-01
-4.41E-01
-4.55E-01
24 Hr
Anneal
60
-4.17E-01
-4.41E-01
-4.53E-01
-4.04E-01
-4.63E-01
-4.50E-01
-4.43E-01
-4.47E-01
-4.24E-01
-4.38E-01
-4.65E-01
168 Hr
Anneal
70
-4.10E-01
-4.34E-01
-4.41E-01
-4.07E-01
-4.50E-01
-4.63E-01
-4.45E-01
-4.59E-01
-4.32E-01
-4.54E-01
-4.54E-01
-4.77E-01 -4.63E-01 -4.56E-01 -4.56E-01 -4.32E-01 -4.36E-01 -4.28E-01
2.50E-02 2.59E-02 2.07E-02 2.02E-02 1.99E-02 2.46E-02 1.91E-02
-4.08E-01 -3.92E-01 -3.99E-01 -4.01E-01 -3.77E-01 -3.68E-01 -3.76E-01
-5.45E-01 -5.34E-01 -5.12E-01 -5.12E-01 -4.86E-01 -5.03E-01 -4.81E-01
-4.64E-01
1.58E-02
-4.20E-01
-5.07E-01
-2.00E-01
PASS
-4.73E-01
1.18E-02
-4.40E-01
-5.05E-01
1.30E-01
PASS
-4.61E-01
1.09E-02
-4.31E-01
-4.91E-01
1.20E-01
PASS
-4.54E-01
6.00E-03
-4.38E-01
-4.70E-01
1.20E-01
PASS
-4.41E-01
1.05E-02
-4.12E-01
-4.70E-01
1.10E-01
PASS
An ISO 9001:2008 and DSCC Certified Company
97
-4.40E-01
1.02E-02
-4.12E-01
-4.68E-01
1.10E-01
PASS
-4.51E-01
1.24E-02
-4.17E-01
-4.85E-01
1.10E-01
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Ps90%/90% (+KTL) Biased
Negative Slew Rate 3 (V/us) @ VS= +/-15V
2.00E-01
1.00E-01
0.00E+00
-1.00E-01
-2.00E-01
-3.00E-01
-4.00E-01
-5.00E-01
-6.00E-01
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.45. Plot of Negative Slew Rate 3 (V/us) @ VS= +/-15V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
98
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.45. Raw data for Negative Slew Rate 3 (V/us) @ VS= +/-15V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Negative Slew Rate 3 (V/us)
@ VS= +/-15V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-4.90E-01
-5.13E-01
-5.20E-01
-4.73E-01
-5.57E-01
-5.07E-01
-4.85E-01
-5.01E-01
-4.92E-01
-5.10E-01
-5.01E-01
Total
10
-4.76E-01
-4.90E-01
-4.91E-01
-4.67E-01
-5.10E-01
-5.18E-01
-5.06E-01
-5.28E-01
-4.85E-01
-4.84E-01
-4.95E-01
Dose (krad(Si))
20
30
-4.75E-01 -4.65E-01
-4.84E-01 -4.87E-01
-5.02E-01 -4.90E-01
-4.65E-01 -4.55E-01
-5.06E-01 -5.06E-01
-5.05E-01 -4.93E-01
-4.88E-01 -4.89E-01
-5.05E-01 -4.97E-01
-4.79E-01 -4.73E-01
-4.92E-01 -4.87E-01
-4.97E-01 -5.08E-01
50
-4.46E-01
-4.72E-01
-4.78E-01
-4.40E-01
-4.85E-01
-4.75E-01
-4.66E-01
-4.81E-01
-4.44E-01
-4.66E-01
-5.03E-01
24 Hr
Anneal
60
-4.50E-01
-4.68E-01
-4.77E-01
-4.37E-01
-4.74E-01
-4.87E-01
-4.70E-01
-4.76E-01
-4.58E-01
-4.74E-01
-5.00E-01
168 Hr
Anneal
70
-4.52E-01
-4.68E-01
-4.75E-01
-4.41E-01
-4.83E-01
-4.96E-01
-4.79E-01
-4.94E-01
-4.59E-01
-4.74E-01
-5.03E-01
-5.11E-01 -4.87E-01 -4.86E-01 -4.81E-01 -4.64E-01 -4.61E-01 -4.64E-01
3.20E-02 1.64E-02 1.75E-02 2.05E-02 2.00E-02 1.71E-02 1.71E-02
-4.23E-01 -4.42E-01 -4.38E-01 -4.25E-01 -4.09E-01 -4.14E-01 -4.17E-01
-5.98E-01 -5.32E-01 -5.34E-01 -5.37E-01 -5.19E-01 -5.08E-01 -5.11E-01
-4.99E-01
1.04E-02
-4.70E-01
-5.28E-01
-2.00E-01
PASS
-5.04E-01
1.96E-02
-4.50E-01
-5.58E-01
1.30E-01
PASS
-4.94E-01
1.13E-02
-4.63E-01
-5.25E-01
1.20E-01
PASS
-4.88E-01
9.12E-03
-4.63E-01
-5.13E-01
1.20E-01
PASS
-4.66E-01
1.40E-02
-4.28E-01
-5.05E-01
1.10E-01
PASS
An ISO 9001:2008 and DSCC Certified Company
99
-4.73E-01
1.05E-02
-4.44E-01
-5.02E-01
1.10E-01
PASS
-4.80E-01
1.52E-02
-4.39E-01
-5.22E-01
1.10E-01
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Ps90%/90% (+KTL) Biased
Negative Slew Rate 4 (V/us) @ VS= +/-15V
2.00E-01
1.00E-01
0.00E+00
-1.00E-01
-2.00E-01
-3.00E-01
-4.00E-01
-5.00E-01
-6.00E-01
0
10
20
30
40
50
Total Dose (krad(Si))
2460Hr
Anneal
16870Hr
Anneal
Figure 5.46. Plot of Negative Slew Rate 4 (V/us) @ VS= +/-15V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
100
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.46. Raw data for Negative Slew Rate 4 (V/us) @ VS= +/-15V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Negative Slew Rate 4 (V/us)
@ VS= +/-15V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-4.90E-01
-4.92E-01
-4.93E-01
-4.64E-01
-5.10E-01
-4.87E-01
-4.82E-01
-4.84E-01
-4.47E-01
-4.68E-01
-4.64E-01
Total
10
-4.65E-01
-4.82E-01
-4.79E-01
-4.48E-01
-4.92E-01
-4.83E-01
-4.93E-01
-4.97E-01
-4.60E-01
-4.57E-01
-4.64E-01
Dose (krad(Si))
20
30
-4.69E-01 -4.61E-01
-4.60E-01 -4.77E-01
-4.78E-01 -4.68E-01
-4.39E-01 -4.40E-01
-4.83E-01 -4.83E-01
-4.79E-01 -4.62E-01
-4.87E-01 -4.76E-01
-4.79E-01 -4.68E-01
-4.40E-01 -4.43E-01
-4.57E-01 -4.53E-01
-4.54E-01 -4.70E-01
50
-4.42E-01
-4.46E-01
-4.45E-01
-4.21E-01
-4.51E-01
-4.42E-01
-4.65E-01
-4.56E-01
-4.26E-01
-4.36E-01
-4.69E-01
24 Hr
Anneal
60
-4.47E-01
-4.43E-01
-4.50E-01
-4.26E-01
-4.63E-01
-4.46E-01
-4.60E-01
-4.47E-01
-4.21E-01
-4.29E-01
-4.56E-01
168 Hr
Anneal
70
-4.42E-01
-4.51E-01
-4.47E-01
-4.10E-01
-4.60E-01
-4.62E-01
-4.75E-01
-4.57E-01
-4.36E-01
-4.36E-01
-4.62E-01
-4.90E-01 -4.73E-01 -4.66E-01 -4.66E-01 -4.41E-01 -4.46E-01 -4.42E-01
1.65E-02 1.71E-02 1.74E-02 1.67E-02 1.16E-02 1.34E-02 1.91E-02
-4.45E-01 -4.26E-01 -4.18E-01 -4.20E-01 -4.09E-01 -4.09E-01 -3.90E-01
-5.35E-01 -5.20E-01 -5.13E-01 -5.12E-01 -4.73E-01 -4.82E-01 -4.94E-01
-4.74E-01
1.66E-02
-4.28E-01
-5.19E-01
-2.00E-01
PASS
-4.78E-01
1.85E-02
-4.27E-01
-5.29E-01
1.30E-01
PASS
-4.68E-01
1.94E-02
-4.15E-01
-5.22E-01
1.20E-01
PASS
-4.60E-01
1.29E-02
-4.25E-01
-4.96E-01
1.20E-01
PASS
-4.45E-01
1.56E-02
-4.02E-01
-4.88E-01
1.10E-01
PASS
An ISO 9001:2008 and DSCC Certified Company
101
-4.41E-01
1.55E-02
-3.98E-01
-4.83E-01
1.10E-01
PASS
-4.53E-01
1.70E-02
-4.07E-01
-5.00E-01
1.10E-01
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Positive Supply Current 5V (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
2.50E-03
2.00E-03
1.50E-03
1.00E-03
5.00E-04
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.47. Plot of Positive Supply Current 5V (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
102
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.47. Raw data for Positive Supply Current 5V (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Positive Supply Current 5V (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
0
10
20
30
50
60
70
59 1.29E-03 1.25E-03 1.26E-03 1.23E-03 1.13E-03 1.13E-03 1.10E-03
149 1.32E-03 1.25E-03 1.26E-03 1.23E-03 1.12E-03 1.12E-03 1.10E-03
233 1.37E-03 1.29E-03 1.31E-03 1.27E-03 1.17E-03 1.17E-03 1.13E-03
310 1.31E-03 1.26E-03 1.27E-03 1.24E-03 1.14E-03 1.14E-03 1.11E-03
393 1.35E-03 1.29E-03 1.28E-03 1.25E-03 1.15E-03 1.15E-03 1.12E-03
443 1.32E-03 1.35E-03 1.33E-03 1.29E-03 1.20E-03 1.21E-03 1.20E-03
516 1.28E-03 1.36E-03 1.32E-03 1.30E-03 1.22E-03 1.22E-03 1.21E-03
574 1.27E-03 1.36E-03 1.33E-03 1.28E-03 1.20E-03 1.21E-03 1.20E-03
589 1.29E-03 1.34E-03 1.31E-03 1.28E-03 1.21E-03 1.22E-03 1.20E-03
732 1.32E-03 1.35E-03 1.32E-03 1.29E-03 1.22E-03 1.22E-03 1.21E-03
829 1.33E-03 1.31E-03 1.31E-03 1.31E-03 1.31E-03 1.32E-03 1.31E-03
Biased Statistics
Average Biased
1.33E-03 1.27E-03 1.28E-03 1.24E-03 1.14E-03 1.14E-03 1.11E-03
Std Dev Biased
3.16E-05 2.02E-05 1.77E-05 1.82E-05 1.97E-05 1.94E-05 1.56E-05
Ps90%/90% (+KTL) Biased
1.41E-03 1.32E-03 1.33E-03 1.29E-03 1.19E-03 1.20E-03 1.15E-03
Ps90%/90% (-KTL) Biased
1.24E-03 1.21E-03 1.23E-03 1.19E-03 1.09E-03 1.09E-03 1.07E-03
Un-Biased Statistics
Average Un-Biased
1.30E-03 1.35E-03 1.32E-03 1.29E-03 1.21E-03 1.22E-03 1.20E-03
Std Dev Un-Biased
2.20E-05 1.17E-05 8.23E-06 7.60E-06 9.87E-06 6.04E-06 7.65E-06
Ps90%/90% (+KTL) Un-Biased
1.36E-03 1.38E-03 1.34E-03 1.31E-03 1.24E-03 1.23E-03 1.22E-03
Ps90%/90% (-KTL) Un-Biased
1.24E-03 1.32E-03 1.30E-03 1.27E-03 1.18E-03 1.20E-03 1.18E-03
Specification MAX
2.00E-03 2.00E-03 2.00E-03 2.00E-03 2.00E-03 2.00E-03 2.00E-03
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
103
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Negative Supply Current 5V (A)
@ VS= +5V , VCM= 0V, VOUT= 1.4V
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
-2.00E-03
-2.50E-03
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.48. Plot of Negative Supply Current 5V (A) @ VS= +5V , VCM= 0V, VOUT= 1.4V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
104
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.48. Raw data for Negative Supply Current 5V (A) @ VS= +5V , VCM= 0V, VOUT= 1.4V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Supply Current 5V (A)
@ VS= +5V , VCM= 0V, VOUT= 1.4V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
-1.27E-03
-1.30E-03
-1.35E-03
-1.29E-03
-1.34E-03
-1.31E-03
-1.28E-03
-1.25E-03
-1.28E-03
-1.29E-03
-1.30E-03
Total
10
-1.25E-03
-1.24E-03
-1.27E-03
-1.24E-03
-1.26E-03
-1.33E-03
-1.33E-03
-1.35E-03
-1.32E-03
-1.32E-03
-1.29E-03
Dose (krad(Si))
20
30
-1.24E-03 -1.20E-03
-1.24E-03 -1.20E-03
-1.29E-03 -1.26E-03
-1.26E-03 -1.22E-03
-1.28E-03 -1.23E-03
-1.31E-03 -1.26E-03
-1.31E-03 -1.28E-03
-1.30E-03 -1.27E-03
-1.29E-03 -1.26E-03
-1.29E-03 -1.27E-03
-1.29E-03 -1.30E-03
50
-1.11E-03
-1.10E-03
-1.15E-03
-1.12E-03
-1.12E-03
-1.19E-03
-1.19E-03
-1.18E-03
-1.19E-03
-1.19E-03
-1.29E-03
24 Hr
Anneal
60
-1.11E-03
-1.09E-03
-1.15E-03
-1.12E-03
-1.13E-03
-1.19E-03
-1.21E-03
-1.19E-03
-1.19E-03
-1.20E-03
-1.30E-03
168 Hr
Anneal
70
-1.08E-03
-1.08E-03
-1.11E-03
-1.09E-03
-1.09E-03
-1.18E-03
-1.19E-03
-1.18E-03
-1.18E-03
-1.18E-03
-1.30E-03
-1.31E-03 -1.25E-03 -1.26E-03 -1.22E-03 -1.12E-03 -1.12E-03 -1.09E-03
3.45E-05 1.32E-05 2.23E-05 2.21E-05 1.78E-05 2.28E-05 1.41E-05
-1.22E-03 -1.22E-03 -1.20E-03 -1.16E-03 -1.07E-03 -1.06E-03 -1.05E-03
-1.41E-03 -1.29E-03 -1.32E-03 -1.28E-03 -1.17E-03 -1.18E-03 -1.13E-03
-1.28E-03
2.17E-05
-1.22E-03
-1.34E-03
-2.00E-03
PASS
-1.33E-03
1.25E-05
-1.30E-03
-1.37E-03
-2.00E-03
PASS
-1.30E-03
9.45E-06
-1.27E-03
-1.33E-03
-2.00E-03
PASS
-1.27E-03
5.36E-06
-1.25E-03
-1.28E-03
-2.00E-03
PASS
-1.19E-03
3.39E-06
-1.18E-03
-1.20E-03
-2.00E-03
PASS
An ISO 9001:2008 and DSCC Certified Company
105
-1.19E-03
8.68E-06
-1.17E-03
-1.22E-03
-2.00E-03
PASS
-1.18E-03
4.98E-06
-1.17E-03
-1.19E-03
-2.00E-03
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Voltage 5V 1 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.00E-03
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.49. Plot of Offset Voltage 5V 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
106
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.49. Raw data for Offset Voltage 5V 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Offset Voltage 5V 1 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-6.73E-05
-1.07E-05
2.93E-05
4.39E-05
3.19E-06
5.49E-06
-2.53E-05
1.26E-06
4.28E-06
6.39E-05
9.44E-05
Total
10
-4.01E-05
4.52E-06
6.74E-05
7.31E-05
2.83E-05
2.50E-05
-7.79E-06
2.15E-05
3.25E-05
9.43E-05
9.59E-05
Dose (krad(Si))
20
30
-2.03E-05 1.02E-06
2.53E-05 4.30E-05
8.55E-05 1.06E-04
9.82E-05 1.16E-04
4.43E-05 5.68E-05
3.38E-05 5.03E-05
7.18E-06 1.90E-05
4.15E-05 5.71E-05
5.34E-05 6.92E-05
1.19E-04 1.38E-04
9.65E-05 9.53E-05
50
3.26E-05
7.61E-05
1.46E-04
1.52E-04
9.05E-05
8.07E-05
5.15E-05
9.09E-05
1.15E-04
1.94E-04
9.65E-05
24 Hr
168 Hr
Anneal
Anneal
60
70
2.93E-05 -1.67E-05
7.30E-05 2.08E-05
1.44E-04 9.90E-05
1.52E-04 9.47E-05
8.98E-05 5.91E-05
8.09E-05 4.01E-05
5.05E-05 1.09E-05
9.12E-05 3.23E-05
1.12E-04 4.70E-05
1.94E-04 1.16E-04
9.59E-05 9.63E-05
-3.30E-07 2.66E-05 4.66E-05 6.46E-05 9.93E-05 9.76E-05 5.14E-05
4.31E-05 4.68E-05 4.77E-05 4.72E-05 4.99E-05 5.11E-05 4.94E-05
1.18E-04 1.55E-04 1.77E-04 1.94E-04 2.36E-04 2.38E-04 1.87E-04
-1.19E-04 -1.02E-04 -8.43E-05 -6.49E-05 -3.75E-05 -4.26E-05 -8.42E-05
9.93E-06
3.27E-05
9.96E-05
-7.98E-05
-4.50E-04
PASS
4.50E-04
PASS
3.31E-05
3.75E-05
1.36E-04
-6.96E-05
-6.00E-04
PASS
6.00E-04
PASS
5.09E-05
4.16E-05
1.65E-04
-6.30E-05
-6.00E-04
PASS
6.00E-04
PASS
6.66E-05
4.38E-05
1.87E-04
-5.34E-05
-6.00E-04
PASS
6.00E-04
PASS
1.06E-04
5.38E-05
2.54E-04
-4.12E-05
-7.50E-04
PASS
7.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
107
1.06E-04
5.40E-05
2.54E-04
-4.23E-05
-7.50E-04
PASS
7.50E-04
PASS
4.92E-05
3.96E-05
1.58E-04
-5.94E-05
-7.50E-04
PASS
7.50E-04
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Voltage 5V 2 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.00E-03
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.50. Plot of Offset Voltage 5V 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
108
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.50. Raw data for Offset Voltage 5V 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Offset Voltage 5V 2 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-6.98E-05
-6.20E-05
-4.58E-05
6.76E-05
-1.85E-07
-8.29E-05
-1.85E-05
-8.15E-06
-5.01E-06
6.29E-05
2.83E-06
Total
10
-3.08E-05
-3.87E-05
-1.02E-05
1.01E-04
3.25E-05
-6.68E-05
5.73E-06
1.03E-05
1.91E-05
8.97E-05
2.83E-06
24 Hr
168 Hr
Anneal
Anneal
Dose (krad(Si))
20
30
50
60
70
-1.03E-05 2.71E-06 4.11E-05 3.77E-05 -4.29E-06
-2.46E-05 -1.50E-05 1.06E-05 9.59E-06 -2.94E-05
4.64E-06 1.85E-05 5.80E-05 5.42E-05 4.65E-06
1.18E-04 1.38E-04 1.88E-04 1.85E-04 1.24E-04
5.03E-05 6.23E-05 1.00E-04 9.90E-05 6.22E-05
-5.84E-05 -4.73E-05 -2.63E-05 -2.60E-05 -6.33E-05
2.49E-05 4.25E-05 8.43E-05 8.08E-05 2.27E-05
2.47E-05 3.82E-05 6.92E-05 6.61E-05 1.70E-05
4.36E-05 6.08E-05 1.11E-04 1.06E-04 4.00E-05
1.09E-04 1.30E-04 1.73E-04 1.70E-04 1.20E-04
2.71E-06 9.01E-07 2.11E-06 1.14E-06 1.39E-06
-2.20E-05 1.07E-05 2.76E-05 4.14E-05 7.95E-05 7.70E-05 3.15E-05
5.69E-05 5.74E-05 5.78E-05 6.13E-05 6.87E-05 6.83E-05 6.18E-05
1.34E-04 1.68E-04 1.86E-04 2.09E-04 2.68E-04 2.64E-04 2.01E-04
-1.78E-04 -1.47E-04 -1.31E-04 -1.27E-04 -1.09E-04 -1.10E-04 -1.38E-04
-1.03E-05
5.18E-05
1.32E-04
-1.52E-04
-4.50E-04
PASS
4.50E-04
PASS
1.16E-05
5.56E-05
1.64E-04
-1.41E-04
-6.00E-04
PASS
6.00E-04
PASS
2.88E-05
5.98E-05
1.93E-04
-1.35E-04
-6.00E-04
PASS
6.00E-04
PASS
4.48E-05
6.32E-05
2.18E-04
-1.29E-04
-6.00E-04
PASS
6.00E-04
PASS
8.22E-05
7.24E-05
2.81E-04
-1.16E-04
-7.50E-04
PASS
7.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
109
7.93E-05
7.10E-05
2.74E-04
-1.15E-04
-7.50E-04
PASS
7.50E-04
PASS
2.73E-05
6.55E-05
2.07E-04
-1.52E-04
-7.50E-04
PASS
7.50E-04
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Voltage 5V 3 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.00E-03
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.51. Plot of Offset Voltage 5V 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
110
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.51. Raw data for Offset Voltage 5V 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Offset Voltage 5V 3 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
Dose (krad(Si))
20
30
2.54E-05 4.09E-05
7.09E-05 8.84E-05
3.16E-05 4.44E-05
4.28E-05 6.05E-05
8.78E-05 9.99E-05
-2.05E-05 -1.03E-05
4.35E-05 5.88E-05
1.07E-04 1.23E-04
3.80E-05 5.49E-05
2.66E-05 4.68E-05
8.67E-05 8.55E-05
50
8.63E-05
1.17E-04
7.52E-05
1.08E-04
1.42E-04
1.90E-05
1.01E-04
1.58E-04
1.01E-04
9.91E-05
8.65E-05
24 Hr
168 Hr
Anneal
Anneal
60
70
8.35E-05 5.04E-05
1.16E-04 8.79E-05
7.40E-05 2.41E-05
1.06E-04 5.15E-05
1.41E-04 9.30E-05
1.54E-05 -1.48E-05
9.67E-05 3.52E-05
1.58E-04 1.00E-04
1.00E-04 3.70E-05
9.59E-05 2.67E-05
8.61E-05 8.70E-05
-3.78E-07 3.25E-05 5.17E-05 6.68E-05
3.23E-05 2.95E-05 2.67E-05 2.63E-05
8.82E-05 1.13E-04 1.25E-04 1.39E-04
-8.90E-05 -4.85E-05 -2.15E-05 -5.45E-06
1.06E-04
2.61E-05
1.77E-04
3.39E-05
1.04E-04 6.14E-05
2.66E-05 2.88E-05
1.77E-04 1.40E-04
3.11E-05 -1.76E-05
0
-3.59E-05
3.76E-05
-1.78E-05
-1.59E-05
3.01E-05
-5.73E-05
-7.91E-06
6.70E-05
-1.03E-05
-1.59E-05
8.62E-05
-4.87E-06
4.49E-05
1.18E-04
-1.28E-04
-4.50E-04
PASS
4.50E-04
PASS
Total
10
3.19E-06
5.71E-05
1.15E-05
2.02E-05
7.03E-05
-3.45E-05
2.12E-05
9.19E-05
1.67E-05
8.38E-06
8.70E-05
2.07E-05
4.55E-05
1.45E-04
-1.04E-04
-6.00E-04
PASS
6.00E-04
PASS
3.89E-05
4.56E-05
1.64E-04
-8.60E-05
-6.00E-04
PASS
6.00E-04
PASS
5.47E-05
4.74E-05
1.85E-04
-7.54E-05
-6.00E-04
PASS
6.00E-04
PASS
9.58E-05
4.96E-05
2.32E-04
-4.04E-05
-7.50E-04
PASS
7.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
111
9.33E-05
5.09E-05
2.33E-04
-4.64E-05
-7.50E-04
PASS
7.50E-04
PASS
3.68E-05
4.11E-05
1.50E-04
-7.59E-05
-7.50E-04
PASS
7.50E-04
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Voltage 5V 4 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.00E-03
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.52. Plot of Offset Voltage 5V 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
112
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.52. Raw data for Offset Voltage 5V 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Offset Voltage 5V 4 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-1.12E-05
-5.50E-05
-1.24E-04
1.62E-05
-1.05E-04
-8.27E-06
-4.11E-05
-3.58E-05
-6.94E-06
1.06E-04
4.64E-06
Total
10
2.21E-05
-2.47E-05
-8.47E-05
5.62E-05
-7.85E-05
1.62E-05
-2.31E-05
-2.11E-05
2.11E-05
1.36E-04
4.40E-06
24 Hr
168 Hr
Anneal
Anneal
Dose (krad(Si))
20
30
50
60
70
3.83E-05 5.14E-05 8.62E-05 8.41E-05 4.79E-05
-9.96E-06 2.98E-07 3.07E-05 2.75E-05 3.32E-06
-6.62E-05 -4.81E-05 -8.39E-06 -1.12E-05 -6.63E-05
7.25E-05 8.88E-05 1.26E-04 1.25E-04 7.71E-05
-6.39E-05 -5.69E-05 -2.79E-05 -2.99E-05 -7.01E-05
2.90E-05 4.17E-05 7.03E-05 6.91E-05 2.40E-05
-8.15E-06 4.28E-06 3.77E-05 3.51E-05 -4.89E-06
-8.03E-06 6.94E-06 3.25E-05 3.24E-05 -8.39E-06
4.35E-05 6.27E-05 1.08E-04 1.08E-04 4.50E-05
1.59E-04 1.80E-04 2.33E-04 2.32E-04 1.52E-04
5.12E-06 3.44E-06 3.92E-06 3.19E-06 3.20E-06
-5.57E-05 -2.19E-05 -5.86E-06 7.08E-06 4.14E-05 3.92E-05 -1.63E-06
5.95E-05 6.16E-05 6.15E-05 6.29E-05 6.45E-05 6.50E-05 6.62E-05
1.08E-04 1.47E-04 1.63E-04 1.80E-04 2.18E-04 2.17E-04 1.80E-04
-2.19E-04 -1.91E-04 -1.74E-04 -1.65E-04 -1.35E-04 -1.39E-04 -1.83E-04
2.81E-06
5.98E-05
1.67E-04
-1.61E-04
-4.50E-04
PASS
4.50E-04
PASS
2.59E-05
6.50E-05
2.04E-04
-1.52E-04
-6.00E-04
PASS
6.00E-04
PASS
4.30E-05
6.86E-05
2.31E-04
-1.45E-04
-6.00E-04
PASS
6.00E-04
PASS
5.91E-05
7.18E-05
2.56E-04
-1.38E-04
-6.00E-04
PASS
6.00E-04
PASS
9.64E-05
8.21E-05
3.22E-04
-1.29E-04
-7.50E-04
PASS
7.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
113
9.54E-05
8.25E-05
3.21E-04
-1.31E-04
-7.50E-04
PASS
7.50E-04
PASS
4.15E-05
6.55E-05
2.21E-04
-1.38E-04
-7.50E-04
PASS
7.50E-04
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Current 5V 1 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.53. Plot of Offset Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
114
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.53. Raw data for Offset Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Offset Current 5V 1 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-1.01E-10
-2.10E-11
-1.39E-10
4.50E-11
1.04E-10
2.10E-11
5.20E-11
-5.90E-11
-8.70E-11
-6.90E-11
-1.01E-10
Total
10
-5.60E-11
-1.00E-11
-1.32E-10
1.70E-11
5.90E-11
5.60E-11
7.00E-12
-1.53E-10
-1.21E-10
-4.50E-11
-9.70E-11
Dose (krad(Si))
20
30
-5.90E-11 -2.15E-10
3.50E-11 -3.80E-11
-1.53E-10 -1.01E-10
7.60E-11 2.91E-10
-6.60E-11 -5.20E-11
-2.80E-11 -1.77E-10
6.90E-11 -7.00E-12
-1.04E-10 -2.88E-10
-1.56E-10 -1.60E-10
-9.40E-11 -1.42E-10
-1.01E-10 -9.40E-11
50
-2.93E-10
8.80E-11
-1.10E-10
1.93E-10
-6.10E-11
-1.04E-10
-3.10E-11
-3.93E-10
-8.50E-11
-2.63E-10
-7.00E-11
24 Hr
Anneal
60
-2.81E-10
8.50E-11
-1.01E-10
1.63E-10
-1.28E-10
-1.87E-10
2.00E-12
-3.10E-10
-1.27E-10
-2.21E-10
-1.05E-10
168 Hr
Anneal
70
-5.31E-10
4.30E-11
-9.00E-12
7.50E-11
-2.92E-10
-1.63E-10
-6.00E-12
-1.91E-10
-1.61E-10
-1.22E-10
-9.60E-11
-2.24E-11 -2.44E-11 -3.34E-11 -2.30E-11 -3.66E-11 -5.24E-11 -1.43E-10
1.00E-10 7.32E-11 9.04E-11 1.89E-10 1.87E-10 1.77E-10 2.61E-10
2.53E-10 1.76E-10 2.14E-10 4.95E-10 4.76E-10 4.34E-10 5.73E-10
-2.98E-10 -2.25E-10 -2.81E-10 -5.41E-10 -5.50E-10 -5.38E-10 -8.59E-10
-2.84E-11
6.11E-11
1.39E-10
-1.96E-10
-1.00E-08
PASS
1.00E-08
PASS
-5.12E-11
8.68E-11
1.87E-10
-2.89E-10
-1.00E-08
PASS
1.00E-08
PASS
-6.26E-11
8.65E-11
1.75E-10
-3.00E-10
-1.00E-08
PASS
1.00E-08
PASS
-1.55E-10
1.00E-10
1.20E-10
-4.30E-10
-1.00E-08
PASS
1.00E-08
PASS
-1.75E-10
1.49E-10
2.34E-10
-5.85E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
115
-1.69E-10
1.16E-10
1.50E-10
-4.87E-10
-1.50E-08
PASS
1.50E-08
PASS
-1.29E-10
7.28E-11
7.10E-11
-3.28E-10
-1.50E-08
PASS
1.50E-08
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Current 5V 2 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.54. Plot of Offset Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
116
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.54. Raw data for Offset Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Offset Current 5V 2 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.80E-11
-5.20E-11
-4.50E-11
-6.60E-11
-1.49E-10
4.50E-11
-1.00E-11
1.42E-10
-3.80E-11
-4.90E-11
-7.30E-11
Total
10
5.60E-11
-7.00E-12
-1.04E-10
1.40E-11
-1.98E-10
2.80E-11
-3.10E-11
1.49E-10
1.70E-11
2.10E-11
-4.50E-11
Dose (krad(Si))
20
30
3.50E-11 1.21E-10
6.90E-11 7.00E-12
2.10E-11 -4.20E-11
3.80E-11 1.11E-10
-2.64E-10 -1.46E-10
-4.90E-11 -2.10E-11
-7.60E-11 -1.70E-11
8.30E-11 8.70E-11
-5.90E-11 -7.60E-11
-4.20E-11 -3.80E-11
-4.90E-11 -3.50E-11
50
1.22E-10
1.20E-10
-2.74E-10
1.12E-10
-2.77E-10
-5.70E-11
-4.40E-11
5.90E-11
-4.20E-11
-1.34E-10
-6.00E-11
24 Hr
Anneal
60
8.50E-11
8.70E-11
-2.26E-10
1.10E-10
-3.77E-10
-7.10E-11
-2.60E-11
1.29E-10
1.50E-11
-1.69E-10
-6.10E-11
168 Hr
Anneal
70
-3.00E-11
6.30E-11
-2.54E-10
7.70E-11
-4.31E-10
1.00E-11
-6.60E-11
7.10E-11
-6.10E-11
-1.31E-10
-6.00E-11
-6.80E-11 -4.78E-11 -2.02E-11 1.02E-11 -3.94E-11 -6.42E-11 -1.15E-10
4.73E-11 1.02E-10 1.37E-10 1.11E-10 2.16E-10 2.23E-10 2.21E-10
6.17E-11 2.33E-10 3.57E-10 3.15E-10 5.52E-10 5.48E-10 4.90E-10
-1.98E-10 -3.29E-10 -3.97E-10 -2.95E-10 -6.30E-10 -6.77E-10 -7.20E-10
1.80E-11
7.83E-11
2.33E-10
-1.97E-10
-1.00E-08
PASS
1.00E-08
PASS
3.68E-11
6.69E-11
2.20E-10
-1.47E-10
-1.00E-08
PASS
1.00E-08
PASS
-2.86E-11
6.37E-11
1.46E-10
-2.03E-10
-1.00E-08
PASS
1.00E-08
PASS
-1.30E-11
6.06E-11
1.53E-10
-1.79E-10
-1.00E-08
PASS
1.00E-08
PASS
-4.36E-11
6.87E-11
1.45E-10
-2.32E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
117
-2.44E-11
1.10E-10
2.76E-10
-3.25E-10
-1.50E-08
PASS
1.50E-08
PASS
-3.54E-11
7.76E-11
1.77E-10
-2.48E-10
-1.50E-08
PASS
1.50E-08
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Current 5V 3 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.55. Plot of Offset Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
118
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.55. Raw data for Offset Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Offset Current 5V 3 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
8.30E-11
3.10E-11
0.00E+00
-3.10E-11
-3.80E-11
-2.80E-11
-1.60E-10
-3.10E-11
-3.50E-11
-9.70E-11
1.42E-10
Total
10
5.90E-11
9.40E-11
7.00E-12
-1.01E-10
-1.08E-10
-1.14E-10
-1.73E-10
-7.60E-11
1.70E-11
-1.08E-10
1.21E-10
Dose (krad(Si))
20
30
-1.70E-11 1.87E-10
3.00E-12 3.10E-11
-2.80E-11 -2.19E-10
-1.21E-10 -1.91E-10
-1.60E-10 -1.39E-10
-1.25E-10 -1.18E-10
-1.84E-10 -2.19E-10
-9.70E-11 -1.70E-11
-1.14E-10 -8.00E-11
-9.70E-11 -1.70E-10
1.08E-10 1.18E-10
50
1.80E-10
8.90E-11
-1.20E-10
-2.34E-10
-3.93E-10
-2.00E-10
-2.44E-10
-1.27E-10
-1.52E-10
-3.07E-10
1.22E-10
24 Hr
Anneal
60
1.91E-10
7.20E-11
-9.60E-11
-2.87E-10
-3.61E-10
-1.61E-10
-2.46E-10
-9.10E-11
-1.43E-10
-3.08E-10
1.12E-10
168 Hr
Anneal
70
-1.40E-10
-1.83E-10
3.00E-12
-8.10E-11
-2.12E-10
-2.04E-10
-3.00E-10
-1.17E-10
-3.30E-11
-3.24E-10
1.29E-10
9.00E-12 -9.80E-12 -6.46E-11 -6.62E-11 -9.56E-11 -9.62E-11 -1.23E-10
4.96E-11 9.19E-11 7.15E-11 1.72E-10 2.34E-10 2.33E-10 8.58E-11
1.45E-10 2.42E-10 1.31E-10 4.04E-10 5.45E-10 5.43E-10 1.13E-10
-1.27E-10 -2.62E-10 -2.61E-10 -5.37E-10 -7.36E-10 -7.35E-10 -3.58E-10
-7.02E-11
5.77E-11
8.81E-11
-2.29E-10
-1.00E-08
PASS
1.00E-08
PASS
-9.08E-11
6.97E-11
1.00E-10
-2.82E-10
-1.00E-08
PASS
1.00E-08
PASS
-1.23E-10
3.59E-11
-2.49E-11
-2.22E-10
-1.00E-08
PASS
1.00E-08
PASS
-1.21E-10
7.83E-11
9.38E-11
-3.35E-10
-1.00E-08
PASS
1.00E-08
PASS
-2.06E-10
7.22E-11
-8.09E-12
-4.04E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
119
-1.90E-10
8.65E-11
4.73E-11
-4.27E-10
-1.50E-08
PASS
1.50E-08
PASS
-1.96E-10
1.23E-10
1.40E-10
-5.32E-10
-1.50E-08
PASS
1.50E-08
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Current 5V 4 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.56. Plot of Offset Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
120
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.56. Raw data for Offset Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Offset Current 5V 4 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
7.00E-12
-9.70E-11
0.00E+00
-6.90E-11
-3.10E-11
2.80E-11
-3.80E-11
1.00E-11
-7.00E-12
-3.10E-11
7.00E-12
Total
10
-5.20E-11
-1.77E-10
-2.10E-11
-3.50E-11
3.00E-12
-9.40E-11
-1.56E-10
-1.21E-10
-1.53E-10
-9.40E-11
2.80E-11
Dose (krad(Si))
20
30
-4.20E-11 -1.25E-10
-1.49E-10 -2.71E-10
-4.20E-11 -9.00E-11
4.20E-11 9.00E-11
-1.35E-10 -9.00E-11
-2.46E-10 -2.81E-10
-2.39E-10 -2.08E-10
-1.56E-10 -2.53E-10
-1.35E-10 -2.46E-10
-1.39E-10 -1.14E-10
1.40E-11 1.00E-11
50
-2.80E-11
-2.25E-10
-9.30E-11
1.03E-10
-3.58E-10
-3.66E-10
-4.49E-10
-3.47E-10
-3.46E-10
-6.60E-11
5.00E-12
24 Hr
Anneal
60
1.20E-11
-1.70E-10
-1.04E-10
1.03E-10
-3.37E-10
-3.64E-10
-3.48E-10
-3.12E-10
-3.58E-10
-9.00E-11
-1.10E-11
168 Hr
Anneal
70
8.90E-11
-2.43E-10
2.80E-11
1.41E-10
-2.23E-10
-1.69E-10
-2.70E-11
-3.00E-11
-5.20E-11
3.00E-12
4.00E-12
-3.80E-11 -5.64E-11 -6.52E-11 -9.72E-11 -1.20E-10 -9.92E-11 -4.16E-11
4.46E-11 7.04E-11 7.82E-11 1.29E-10 1.78E-10 1.69E-10 1.79E-10
8.43E-11 1.37E-10 1.49E-10 2.55E-10 3.68E-10 3.65E-10 4.50E-10
-1.60E-10 -2.49E-10 -2.80E-10 -4.50E-10 -6.08E-10 -5.64E-10 -5.33E-10
-7.60E-12
2.76E-11
6.81E-11
-8.33E-11
-1.00E-08
PASS
1.00E-08
PASS
-1.24E-10
3.03E-11
-4.05E-11
-2.07E-10
-1.00E-08
PASS
1.00E-08
PASS
-1.83E-10
5.49E-11
-3.24E-11
-3.34E-10
-1.00E-08
PASS
1.00E-08
PASS
-2.20E-10
6.49E-11
-4.24E-11
-3.98E-10
-1.00E-08
PASS
1.00E-08
PASS
-3.15E-10
1.45E-10
8.38E-11
-7.13E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
121
-2.94E-10
1.16E-10
2.38E-11
-6.13E-10
-1.50E-08
PASS
1.50E-08
PASS
-5.50E-11
6.67E-11
1.28E-10
-2.38E-10
-1.50E-08
PASS
1.50E-08
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 5V 1 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.57. Plot of Positive Bias Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
122
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.57. Raw data for Positive Bias Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Positive Bias Current 5V 1 (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
0
10
20
30
50
60
70
59 1.19E-08 1.52E-08 1.94E-08 2.35E-08 3.28E-08 3.30E-08 3.01E-08
149 1.16E-08 1.47E-08 1.89E-08 2.31E-08 3.22E-08 3.24E-08 2.90E-08
233 1.20E-08 1.50E-08 1.93E-08 2.33E-08 3.25E-08 3.27E-08 2.97E-08
310 1.17E-08 1.48E-08 1.91E-08 2.30E-08 3.24E-08 3.26E-08 2.97E-08
393 1.16E-08 1.50E-08 1.95E-08 2.37E-08 3.32E-08 3.34E-08 3.01E-08
443 1.18E-08 1.46E-08 1.75E-08 2.02E-08 2.64E-08 2.62E-08 2.30E-08
516 1.12E-08 1.40E-08 1.66E-08 1.93E-08 2.52E-08 2.50E-08 2.20E-08
574 1.14E-08 1.43E-08 1.70E-08 1.96E-08 2.57E-08 2.55E-08 2.23E-08
589 1.23E-08 1.50E-08 1.79E-08 2.05E-08 2.66E-08 2.65E-08 2.36E-08
732 1.17E-08 1.43E-08 1.71E-08 1.96E-08 2.58E-08 2.55E-08 2.26E-08
829 1.24E-08 1.24E-08 1.23E-08 1.24E-08 1.24E-08 1.24E-08 1.24E-08
Biased Statistics
Average Biased
1.18E-08 1.49E-08 1.92E-08 2.33E-08 3.26E-08 3.28E-08 2.97E-08
Std Dev Biased
1.88E-10 1.98E-10 2.18E-10 2.66E-10 3.59E-10 3.88E-10 4.28E-10
Ps90%/90% (+KTL) Biased
1.23E-08 1.55E-08 1.98E-08 2.40E-08 3.36E-08 3.39E-08 3.09E-08
Ps90%/90% (-KTL) Biased
1.13E-08 1.44E-08 1.86E-08 2.26E-08 3.16E-08 3.17E-08 2.85E-08
Un-Biased Statistics
Average Un-Biased
1.17E-08 1.44E-08 1.72E-08 1.98E-08 2.60E-08 2.57E-08 2.27E-08
Std Dev Un-Biased
4.22E-10 3.81E-10 4.82E-10 4.95E-10 5.76E-10 5.99E-10 6.23E-10
Ps90%/90% (+KTL) Un-Biased
1.28E-08 1.55E-08 1.85E-08 2.12E-08 2.75E-08 2.74E-08 2.44E-08
Ps90%/90% (-KTL) Un-Biased
1.05E-08 1.34E-08 1.59E-08 1.85E-08 2.44E-08 2.41E-08 2.10E-08
Specification MIN
-5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 -1.25E-07 -1.25E-07 -1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08 8.00E-08 1.00E-07 1.00E-07 1.25E-07 1.25E-07 1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
123
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 5V 2 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.58. Plot of Positive Bias Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
124
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.58. Raw data for Positive Bias Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Positive Bias Current 5V 2 (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
0
10
20
30
50
60
70
59 1.14E-08 1.44E-08 1.85E-08 2.24E-08 3.15E-08 3.18E-08 2.90E-08
149 1.11E-08 1.41E-08 1.82E-08 2.22E-08 3.11E-08 3.13E-08 2.80E-08
233 1.17E-08 1.47E-08 1.89E-08 2.30E-08 3.25E-08 3.26E-08 2.97E-08
310 1.20E-08 1.50E-08 1.93E-08 2.33E-08 3.25E-08 3.26E-08 2.97E-08
393 1.16E-08 1.47E-08 1.90E-08 2.32E-08 3.25E-08 3.28E-08 2.93E-08
443 1.08E-08 1.33E-08 1.60E-08 1.84E-08 2.43E-08 2.41E-08 2.10E-08
516 1.14E-08 1.40E-08 1.67E-08 1.92E-08 2.52E-08 2.50E-08 2.20E-08
574 1.07E-08 1.33E-08 1.59E-08 1.84E-08 2.41E-08 2.39E-08 2.09E-08
589 1.19E-08 1.45E-08 1.73E-08 1.99E-08 2.61E-08 2.58E-08 2.30E-08
732 1.15E-08 1.41E-08 1.67E-08 1.93E-08 2.53E-08 2.51E-08 2.20E-08
829 1.12E-08 1.12E-08 1.12E-08 1.13E-08 1.12E-08 1.12E-08 1.12E-08
Biased Statistics
Average Biased
1.16E-08 1.46E-08 1.88E-08 2.28E-08 3.20E-08 3.22E-08 2.91E-08
Std Dev Biased
3.29E-10 3.35E-10 4.26E-10 4.71E-10 6.51E-10 6.48E-10 6.95E-10
Ps90%/90% (+KTL) Biased
1.25E-08 1.55E-08 1.99E-08 2.41E-08 3.38E-08 3.40E-08 3.10E-08
Ps90%/90% (-KTL) Biased
1.07E-08 1.36E-08 1.76E-08 2.15E-08 3.02E-08 3.04E-08 2.72E-08
Un-Biased Statistics
Average Un-Biased
1.12E-08 1.39E-08 1.65E-08 1.91E-08 2.50E-08 2.48E-08 2.18E-08
Std Dev Un-Biased
5.10E-10 5.24E-10 5.82E-10 6.37E-10 7.97E-10 7.85E-10 8.70E-10
Ps90%/90% (+KTL) Un-Biased
1.26E-08 1.53E-08 1.81E-08 2.08E-08 2.72E-08 2.69E-08 2.42E-08
Ps90%/90% (-KTL) Un-Biased
9.84E-09 1.24E-08 1.49E-08 1.73E-08 2.28E-08 2.26E-08 1.94E-08
Specification MIN
-5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 -1.25E-07 -1.25E-07 -1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08 8.00E-08 1.00E-07 1.00E-07 1.25E-07 1.25E-07 1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
125
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 5V 3 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.59. Plot of Positive Bias Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
126
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.59. Raw data for Positive Bias Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Positive Bias Current 5V 3 (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
0
10
20
30
50
60
70
59 1.25E-08 1.57E-08 2.02E-08 2.43E-08 3.40E-08 3.41E-08 3.15E-08
149 1.17E-08 1.48E-08 1.91E-08 2.32E-08 3.24E-08 3.26E-08 2.93E-08
233 1.15E-08 1.45E-08 1.89E-08 2.30E-08 3.23E-08 3.24E-08 2.93E-08
310 1.23E-08 1.55E-08 2.00E-08 2.43E-08 3.37E-08 3.39E-08 3.10E-08
393 1.18E-08 1.52E-08 1.96E-08 2.39E-08 3.36E-08 3.38E-08 3.03E-08
443 1.19E-08 1.45E-08 1.73E-08 1.99E-08 2.61E-08 2.59E-08 2.28E-08
516 1.20E-08 1.46E-08 1.73E-08 1.98E-08 2.59E-08 2.57E-08 2.27E-08
574 1.18E-08 1.46E-08 1.74E-08 2.00E-08 2.62E-08 2.58E-08 2.28E-08
589 1.23E-08 1.49E-08 1.78E-08 2.05E-08 2.68E-08 2.66E-08 2.35E-08
732 1.20E-08 1.46E-08 1.73E-08 1.99E-08 2.61E-08 2.58E-08 2.29E-08
829 1.16E-08 1.16E-08 1.15E-08 1.16E-08 1.16E-08 1.16E-08 1.16E-08
Biased Statistics
Average Biased
1.20E-08 1.51E-08 1.95E-08 2.37E-08 3.32E-08 3.33E-08 3.03E-08
Std Dev Biased
4.18E-10 5.01E-10 5.53E-10 5.92E-10 7.93E-10 8.05E-10 1.00E-09
Ps90%/90% (+KTL) Biased
1.31E-08 1.65E-08 2.11E-08 2.54E-08 3.54E-08 3.55E-08 3.30E-08
Ps90%/90% (-KTL) Biased
1.08E-08 1.38E-08 1.80E-08 2.21E-08 3.10E-08 3.11E-08 2.75E-08
Un-Biased Statistics
Average Un-Biased
1.20E-08 1.46E-08 1.74E-08 2.00E-08 2.62E-08 2.60E-08 2.30E-08
Std Dev Un-Biased
1.91E-10 1.67E-10 2.29E-10 2.71E-10 3.52E-10 3.47E-10 3.40E-10
Ps90%/90% (+KTL) Un-Biased
1.25E-08 1.51E-08 1.81E-08 2.08E-08 2.72E-08 2.69E-08 2.39E-08
Ps90%/90% (-KTL) Un-Biased
1.15E-08 1.42E-08 1.68E-08 1.93E-08 2.53E-08 2.50E-08 2.20E-08
Specification MIN
-5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 -1.25E-07 -1.25E-07 -1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08 8.00E-08 1.00E-07 1.00E-07 1.25E-07 1.25E-07 1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
127
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 5V 4 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.60. Plot of Positive Bias Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
128
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.60. Raw data for Positive Bias Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Positive Bias Current 5V 4 (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
0
10
20
30
50
60
70
59 1.16E-08 1.48E-08 1.89E-08 2.28E-08 3.17E-08 3.18E-08 2.89E-08
149 1.11E-08 1.42E-08 1.83E-08 2.22E-08 3.10E-08 3.12E-08 2.79E-08
233 1.10E-08 1.38E-08 1.78E-08 2.16E-08 3.02E-08 3.04E-08 2.75E-08
310 1.15E-08 1.45E-08 1.87E-08 2.25E-08 3.15E-08 3.17E-08 2.88E-08
393 1.08E-08 1.39E-08 1.81E-08 2.20E-08 3.11E-08 3.13E-08 2.79E-08
443 1.13E-08 1.40E-08 1.68E-08 1.93E-08 2.54E-08 2.52E-08 2.19E-08
516 1.09E-08 1.35E-08 1.62E-08 1.87E-08 2.45E-08 2.43E-08 2.13E-08
574 1.09E-08 1.36E-08 1.63E-08 1.88E-08 2.47E-08 2.45E-08 2.13E-08
589 1.18E-08 1.44E-08 1.70E-08 1.97E-08 2.57E-08 2.55E-08 2.25E-08
732 1.14E-08 1.40E-08 1.67E-08 1.93E-08 2.51E-08 2.50E-08 2.19E-08
829 1.19E-08 1.18E-08 1.18E-08 1.19E-08 1.19E-08 1.18E-08 1.18E-08
Biased Statistics
Average Biased
1.12E-08 1.43E-08 1.84E-08 2.22E-08 3.11E-08 3.13E-08 2.82E-08
Std Dev Biased
3.40E-10 4.20E-10 4.47E-10 4.70E-10 5.68E-10 5.73E-10 6.24E-10
Ps90%/90% (+KTL) Biased
1.21E-08 1.54E-08 1.96E-08 2.35E-08 3.27E-08 3.28E-08 2.99E-08
Ps90%/90% (-KTL) Biased
1.03E-08 1.31E-08 1.71E-08 2.09E-08 2.95E-08 2.97E-08 2.65E-08
Un-Biased Statistics
Average Un-Biased
1.12E-08 1.39E-08 1.66E-08 1.91E-08 2.51E-08 2.49E-08 2.18E-08
Std Dev Un-Biased
3.95E-10 3.32E-10 3.48E-10 4.01E-10 4.87E-10 5.02E-10 5.12E-10
Ps90%/90% (+KTL) Un-Biased
1.23E-08 1.48E-08 1.75E-08 2.02E-08 2.64E-08 2.63E-08 2.32E-08
Ps90%/90% (-KTL) Un-Biased
1.02E-08 1.30E-08 1.56E-08 1.80E-08 2.37E-08 2.35E-08 2.04E-08
Specification MIN
-5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 -1.25E-07 -1.25E-07 -1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08 8.00E-08 1.00E-07 1.00E-07 1.25E-07 1.25E-07 1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
129
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 5V 1 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.61. Plot of Negative Bias Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
130
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.61. Raw data for Negative Bias Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Negative Bias Current 5V 1 (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
0
10
20
30
50
60
70
59 1.19E-08 1.51E-08 1.94E-08 2.33E-08 3.26E-08 3.28E-08 2.97E-08
149 1.16E-08 1.47E-08 1.91E-08 2.31E-08 3.23E-08 3.25E-08 2.91E-08
233 1.19E-08 1.49E-08 1.91E-08 2.32E-08 3.25E-08 3.26E-08 2.98E-08
310 1.18E-08 1.49E-08 1.92E-08 2.33E-08 3.27E-08 3.28E-08 2.98E-08
393 1.17E-08 1.50E-08 1.95E-08 2.36E-08 3.32E-08 3.33E-08 2.98E-08
443 1.18E-08 1.47E-08 1.75E-08 2.01E-08 2.63E-08 2.61E-08 2.28E-08
516 1.13E-08 1.40E-08 1.68E-08 1.92E-08 2.53E-08 2.50E-08 2.21E-08
574 1.13E-08 1.42E-08 1.69E-08 1.94E-08 2.54E-08 2.52E-08 2.21E-08
589 1.23E-08 1.50E-08 1.77E-08 2.04E-08 2.67E-08 2.64E-08 2.35E-08
732 1.18E-08 1.43E-08 1.70E-08 1.95E-08 2.55E-08 2.53E-08 2.25E-08
829 1.23E-08 1.23E-08 1.23E-08 1.23E-08 1.23E-08 1.23E-08 1.23E-08
Biased Statistics
Average Biased
1.18E-08 1.49E-08 1.92E-08 2.33E-08 3.26E-08 3.28E-08 2.96E-08
Std Dev Biased
1.45E-10 1.58E-10 1.77E-10 1.94E-10 3.17E-10 2.97E-10 2.96E-10
Ps90%/90% (+KTL) Biased
1.22E-08 1.54E-08 1.97E-08 2.38E-08 3.35E-08 3.36E-08 3.04E-08
Ps90%/90% (-KTL) Biased
1.14E-08 1.45E-08 1.88E-08 2.28E-08 3.18E-08 3.20E-08 2.88E-08
Un-Biased Statistics
Average Un-Biased
1.17E-08 1.44E-08 1.72E-08 1.97E-08 2.58E-08 2.56E-08 2.26E-08
Std Dev Un-Biased
3.91E-10 4.01E-10 3.95E-10 5.05E-10 6.13E-10 5.84E-10 5.88E-10
Ps90%/90% (+KTL) Un-Biased
1.28E-08 1.55E-08 1.83E-08 2.11E-08 2.75E-08 2.72E-08 2.42E-08
Ps90%/90% (-KTL) Un-Biased
1.06E-08 1.33E-08 1.61E-08 1.83E-08 2.42E-08 2.40E-08 2.10E-08
Specification MIN
-5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 -1.25E-07 -1.25E-07 -1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08 8.00E-08 1.00E-07 1.00E-07 1.25E-07 1.25E-07 1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
131
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 5V 2 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.62. Plot of Negative Bias Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
132
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.62. Raw data for Negative Bias Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Negative Bias Current 5V 2 (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
0
10
20
30
50
60
70
59 1.14E-08 1.45E-08 1.86E-08 2.26E-08 3.16E-08 3.18E-08 2.90E-08
149 1.11E-08 1.41E-08 1.83E-08 2.23E-08 3.13E-08 3.15E-08 2.81E-08
233 1.16E-08 1.46E-08 1.89E-08 2.30E-08 3.22E-08 3.24E-08 2.95E-08
310 1.19E-08 1.50E-08 1.94E-08 2.34E-08 3.26E-08 3.28E-08 2.98E-08
393 1.15E-08 1.45E-08 1.88E-08 2.30E-08 3.23E-08 3.25E-08 2.89E-08
443 1.08E-08 1.34E-08 1.61E-08 1.85E-08 2.43E-08 2.41E-08 2.10E-08
516 1.13E-08 1.40E-08 1.67E-08 1.92E-08 2.52E-08 2.50E-08 2.19E-08
574 1.09E-08 1.35E-08 1.61E-08 1.85E-08 2.43E-08 2.41E-08 2.10E-08
589 1.19E-08 1.46E-08 1.73E-08 1.99E-08 2.60E-08 2.58E-08 2.30E-08
732 1.15E-08 1.40E-08 1.68E-08 1.93E-08 2.52E-08 2.50E-08 2.19E-08
829 1.12E-08 1.12E-08 1.11E-08 1.12E-08 1.12E-08 1.12E-08 1.12E-08
Biased Statistics
Average Biased
1.15E-08 1.45E-08 1.88E-08 2.28E-08 3.20E-08 3.22E-08 2.91E-08
Std Dev Biased
3.18E-10 3.15E-10 3.78E-10 4.24E-10 5.39E-10 5.40E-10 6.69E-10
Ps90%/90% (+KTL) Biased
1.24E-08 1.54E-08 1.98E-08 2.40E-08 3.35E-08 3.37E-08 3.09E-08
Ps90%/90% (-KTL) Biased
1.06E-08 1.37E-08 1.78E-08 2.17E-08 3.05E-08 3.07E-08 2.72E-08
Un-Biased Statistics
Average Un-Biased
1.13E-08 1.39E-08 1.66E-08 1.91E-08 2.50E-08 2.48E-08 2.18E-08
Std Dev Un-Biased
4.47E-10 4.97E-10 5.34E-10 6.05E-10 7.24E-10 7.25E-10 8.23E-10
Ps90%/90% (+KTL) Un-Biased
1.25E-08 1.53E-08 1.81E-08 2.07E-08 2.70E-08 2.68E-08 2.40E-08
Ps90%/90% (-KTL) Un-Biased
1.01E-08 1.25E-08 1.51E-08 1.74E-08 2.30E-08 2.28E-08 1.95E-08
Specification MIN
-5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 -1.25E-07 -1.25E-07 -1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08 8.00E-08 1.00E-07 1.00E-07 1.25E-07 1.25E-07 1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
133
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 5V 3 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.63. Plot of Negative Bias Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
134
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.63. Raw data for Negative Bias Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Negative Bias Current 5V 3 (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
0
10
20
30
50
60
70
59 1.26E-08 1.58E-08 2.02E-08 2.45E-08 3.42E-08 3.44E-08 3.14E-08
149 1.17E-08 1.48E-08 1.92E-08 2.32E-08 3.26E-08 3.27E-08 2.92E-08
233 1.15E-08 1.46E-08 1.88E-08 2.28E-08 3.22E-08 3.23E-08 2.93E-08
310 1.24E-08 1.54E-08 1.99E-08 2.41E-08 3.35E-08 3.37E-08 3.09E-08
393 1.18E-08 1.51E-08 1.95E-08 2.38E-08 3.33E-08 3.35E-08 3.01E-08
443 1.19E-08 1.44E-08 1.73E-08 1.98E-08 2.60E-08 2.58E-08 2.27E-08
516 1.18E-08 1.44E-08 1.72E-08 1.96E-08 2.57E-08 2.55E-08 2.25E-08
574 1.17E-08 1.45E-08 1.73E-08 2.00E-08 2.61E-08 2.58E-08 2.27E-08
589 1.23E-08 1.49E-08 1.77E-08 2.05E-08 2.67E-08 2.65E-08 2.36E-08
732 1.20E-08 1.45E-08 1.72E-08 1.98E-08 2.58E-08 2.56E-08 2.26E-08
829 1.18E-08 1.17E-08 1.17E-08 1.18E-08 1.17E-08 1.18E-08 1.18E-08
Biased Statistics
Average Biased
1.20E-08 1.52E-08 1.95E-08 2.37E-08 3.32E-08 3.33E-08 3.02E-08
Std Dev Biased
4.77E-10 4.93E-10 5.60E-10 6.68E-10 7.66E-10 8.19E-10 9.55E-10
Ps90%/90% (+KTL) Biased
1.33E-08 1.65E-08 2.10E-08 2.55E-08 3.53E-08 3.56E-08 3.28E-08
Ps90%/90% (-KTL) Biased
1.07E-08 1.38E-08 1.80E-08 2.19E-08 3.11E-08 3.11E-08 2.76E-08
Un-Biased Statistics
Average Un-Biased
1.19E-08 1.45E-08 1.73E-08 1.99E-08 2.61E-08 2.58E-08 2.28E-08
Std Dev Un-Biased
2.34E-10 2.29E-10 2.33E-10 3.23E-10 3.83E-10 4.02E-10 4.44E-10
Ps90%/90% (+KTL) Un-Biased
1.26E-08 1.52E-08 1.80E-08 2.08E-08 2.71E-08 2.69E-08 2.40E-08
Ps90%/90% (-KTL) Un-Biased
1.13E-08 1.39E-08 1.67E-08 1.90E-08 2.50E-08 2.47E-08 2.16E-08
Specification MIN
-5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 -1.25E-07 -1.25E-07 -1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08 8.00E-08 1.00E-07 1.00E-07 1.25E-07 1.25E-07 1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
135
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 5V 4 (A)
@ VS= +5V, VCM= 0V, VOUT= 1.4V
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.64. Plot of Negative Bias Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
136
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.64. Raw data for Negative Bias Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Negative Bias Current 5V 4 (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS= +5V, VCM= 0V, VOUT= 1.4V
Device
0
10
20
30
50
60
70
59 1.17E-08 1.47E-08 1.89E-08 2.27E-08 3.17E-08 3.19E-08 2.91E-08
149 1.10E-08 1.41E-08 1.81E-08 2.20E-08 3.08E-08 3.10E-08 2.77E-08
233 1.10E-08 1.38E-08 1.78E-08 2.15E-08 3.01E-08 3.03E-08 2.76E-08
310 1.14E-08 1.46E-08 1.87E-08 2.26E-08 3.16E-08 3.18E-08 2.90E-08
393 1.08E-08 1.39E-08 1.80E-08 2.19E-08 3.08E-08 3.10E-08 2.77E-08
443 1.14E-08 1.39E-08 1.66E-08 1.91E-08 2.51E-08 2.48E-08 2.18E-08
516 1.08E-08 1.34E-08 1.60E-08 1.85E-08 2.42E-08 2.40E-08 2.13E-08
574 1.08E-08 1.35E-08 1.62E-08 1.86E-08 2.44E-08 2.42E-08 2.14E-08
589 1.18E-08 1.42E-08 1.69E-08 1.95E-08 2.54E-08 2.52E-08 2.25E-08
732 1.14E-08 1.39E-08 1.66E-08 1.91E-08 2.51E-08 2.49E-08 2.20E-08
829 1.18E-08 1.18E-08 1.18E-08 1.19E-08 1.18E-08 1.18E-08 1.19E-08
Biased Statistics
Average Biased
1.12E-08 1.42E-08 1.83E-08 2.22E-08 3.10E-08 3.12E-08 2.82E-08
Std Dev Biased
3.52E-10 4.09E-10 4.78E-10 5.09E-10 6.58E-10 6.81E-10 7.52E-10
Ps90%/90% (+KTL) Biased
1.21E-08 1.53E-08 1.96E-08 2.36E-08 3.28E-08 3.31E-08 3.03E-08
Ps90%/90% (-KTL) Biased
1.02E-08 1.31E-08 1.70E-08 2.08E-08 2.92E-08 2.93E-08 2.61E-08
Un-Biased Statistics
Average Un-Biased
1.12E-08 1.38E-08 1.65E-08 1.89E-08 2.48E-08 2.47E-08 2.18E-08
Std Dev Un-Biased
4.01E-10 3.26E-10 3.78E-10 3.92E-10 5.10E-10 5.00E-10 4.89E-10
Ps90%/90% (+KTL) Un-Biased
1.23E-08 1.47E-08 1.75E-08 2.00E-08 2.62E-08 2.60E-08 2.31E-08
Ps90%/90% (-KTL) Un-Biased
1.01E-08 1.29E-08 1.54E-08 1.79E-08 2.34E-08 2.33E-08 2.05E-08
Specification MIN
-5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 -1.25E-07 -1.25E-07 -1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08 8.00E-08 1.00E-07 1.00E-07 1.25E-07 1.25E-07 1.25E-07
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
137
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 5V OPEN 1 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
4.35E+00
4.30E+00
4.25E+00
4.20E+00
4.15E+00
4.10E+00
4.05E+00
4.00E+00
3.95E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.65. Plot of Positive Output Voltage 5V OPEN 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose. The solid diamonds are the average of the measured data points for the samples
irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the
samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or
maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
138
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.65. Raw data for Positive Output Voltage 5V OPEN 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 5V OPEN 1 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.25E+00
Total
10
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.27E+00
4.25E+00
4.25E+00
4.25E+00
4.25E+00
4.25E+00
4.25E+00
Dose (krad(Si))
20
30
4.26E+00 4.27E+00
4.26E+00 4.27E+00
4.26E+00 4.26E+00
4.25E+00 4.26E+00
4.26E+00 4.27E+00
4.25E+00 4.26E+00
4.25E+00 4.26E+00
4.25E+00 4.26E+00
4.25E+00 4.25E+00
4.25E+00 4.25E+00
4.25E+00 4.25E+00
50
4.30E+00
4.30E+00
4.29E+00
4.29E+00
4.31E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.25E+00
24 Hr
Anneal
60
4.30E+00
4.30E+00
4.29E+00
4.29E+00
4.31E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.25E+00
168 Hr
Anneal
70
4.30E+00
4.31E+00
4.31E+00
4.30E+00
4.31E+00
4.28E+00
4.27E+00
4.28E+00
4.27E+00
4.27E+00
4.25E+00
4.26E+00 4.26E+00 4.26E+00 4.27E+00 4.30E+00 4.30E+00 4.31E+00
3.83E-03 2.88E-03 3.51E-03 4.77E-03 7.23E-03 7.77E-03 2.88E-03
4.27E+00 4.27E+00 4.27E+00 4.28E+00 4.32E+00 4.32E+00 4.31E+00
4.25E+00 4.25E+00 4.25E+00 4.25E+00 4.28E+00 4.28E+00 4.30E+00
4.26E+00
3.21E-03
4.27E+00
4.25E+00
4.00E+00
PASS
4.25E+00
2.55E-03
4.26E+00
4.24E+00
4.00E+00
PASS
4.25E+00
2.59E-03
4.26E+00
4.24E+00
4.00E+00
PASS
4.26E+00
2.77E-03
4.26E+00
4.25E+00
4.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
139
4.27E+00
2.59E-03
4.27E+00
4.26E+00
4.00E+00
PASS
4.27E+00
2.97E-03
4.28E+00
4.26E+00
4.00E+00
PASS
4.27E+00
2.88E-03
4.28E+00
4.27E+00
4.00E+00
PASS
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 5V OPEN 2 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
4.35E+00
4.30E+00
4.25E+00
4.20E+00
4.15E+00
4.10E+00
4.05E+00
4.00E+00
3.95E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.66. Plot of Positive Output Voltage 5V OPEN 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose. The solid diamonds are the average of the measured data points for the samples
irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the
samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or
maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
140
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.66. Raw data for Positive Output Voltage 5V OPEN 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 5V OPEN 2 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
4.28E+00
4.28E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.28E+00
4.27E+00
4.27E+00
4.27E+00
Total
10
4.28E+00
4.28E+00
4.28E+00
4.28E+00
4.29E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.27E+00
Dose (krad(Si))
20
30
4.28E+00 4.29E+00
4.28E+00 4.29E+00
4.28E+00 4.29E+00
4.27E+00 4.28E+00
4.28E+00 4.29E+00
4.26E+00 4.27E+00
4.26E+00 4.27E+00
4.26E+00 4.27E+00
4.26E+00 4.27E+00
4.26E+00 4.27E+00
4.27E+00 4.27E+00
50
4.30E+00
4.31E+00
4.30E+00
4.30E+00
4.30E+00
4.29E+00
4.29E+00
4.28E+00
4.29E+00
4.28E+00
4.27E+00
24 Hr
Anneal
60
4.30E+00
4.31E+00
4.30E+00
4.30E+00
4.31E+00
4.29E+00
4.29E+00
4.28E+00
4.29E+00
4.28E+00
4.27E+00
168 Hr
Anneal
70
4.30E+00
4.31E+00
4.30E+00
4.30E+00
4.30E+00
4.29E+00
4.30E+00
4.29E+00
4.30E+00
4.29E+00
4.27E+00
4.27E+00 4.28E+00 4.28E+00 4.29E+00 4.30E+00 4.30E+00 4.30E+00
4.32E-03 2.77E-03 3.49E-03 4.39E-03 3.19E-03 2.83E-03 3.19E-03
4.28E+00 4.29E+00 4.29E+00 4.30E+00 4.31E+00 4.31E+00 4.31E+00
4.26E+00 4.28E+00 4.27E+00 4.28E+00 4.29E+00 4.30E+00 4.29E+00
4.27E+00
4.44E-03
4.28E+00
4.26E+00
4.00E+00
PASS
4.26E+00
1.41E-03
4.26E+00
4.26E+00
4.00E+00
PASS
4.26E+00
1.30E-03
4.27E+00
4.26E+00
4.00E+00
PASS
4.27E+00
1.10E-03
4.27E+00
4.27E+00
4.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
141
4.29E+00
1.82E-03
4.29E+00
4.28E+00
4.00E+00
PASS
4.29E+00
1.30E-03
4.29E+00
4.28E+00
4.00E+00
PASS
4.29E+00
3.03E-03
4.30E+00
4.29E+00
4.00E+00
PASS
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 5V OPEN 3 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
4.35E+00
4.30E+00
4.25E+00
4.20E+00
4.15E+00
4.10E+00
4.05E+00
4.00E+00
3.95E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.67. Plot of Positive Output Voltage 5V OPEN 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose. The solid diamonds are the average of the measured data points for the samples
irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the
samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or
maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
142
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.67. Raw data for Positive Output Voltage 5V OPEN 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 5V OPEN 3 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
4.26E+00
4.27E+00
4.25E+00
4.25E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.25E+00
Total
10
4.27E+00
4.27E+00
4.26E+00
4.26E+00
4.26E+00
4.25E+00
4.25E+00
4.25E+00
4.25E+00
4.25E+00
4.25E+00
Dose (krad(Si))
20
30
4.26E+00 4.27E+00
4.27E+00 4.27E+00
4.26E+00 4.26E+00
4.26E+00 4.26E+00
4.26E+00 4.27E+00
4.25E+00 4.26E+00
4.25E+00 4.25E+00
4.25E+00 4.26E+00
4.25E+00 4.25E+00
4.25E+00 4.25E+00
4.25E+00 4.25E+00
50
4.30E+00
4.31E+00
4.30E+00
4.29E+00
4.30E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.25E+00
24 Hr
Anneal
60
4.30E+00
4.31E+00
4.30E+00
4.29E+00
4.30E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.25E+00
168 Hr
Anneal
70
4.30E+00
4.31E+00
4.30E+00
4.30E+00
4.31E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.25E+00
4.26E+00 4.26E+00 4.26E+00 4.27E+00 4.30E+00 4.30E+00 4.30E+00
5.89E-03 3.27E-03 3.70E-03 4.09E-03 7.40E-03 6.91E-03 3.19E-03
4.27E+00 4.27E+00 4.27E+00 4.28E+00 4.32E+00 4.32E+00 4.31E+00
4.24E+00 4.26E+00 4.25E+00 4.25E+00 4.28E+00 4.28E+00 4.30E+00
4.26E+00
3.35E-03
4.27E+00
4.25E+00
4.00E+00
PASS
4.25E+00
1.95E-03
4.25E+00
4.24E+00
4.00E+00
PASS
4.25E+00
2.28E-03
4.26E+00
4.24E+00
4.00E+00
PASS
4.25E+00
2.05E-03
4.26E+00
4.25E+00
4.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
143
4.27E+00
1.41E-03
4.27E+00
4.26E+00
4.00E+00
PASS
4.27E+00
1.82E-03
4.27E+00
4.26E+00
4.00E+00
PASS
4.27E+00
1.52E-03
4.28E+00
4.27E+00
4.00E+00
PASS
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 5V OPEN 4 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
4.35E+00
4.30E+00
4.25E+00
4.20E+00
4.15E+00
4.10E+00
4.05E+00
4.00E+00
3.95E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.68. Plot of Positive Output Voltage 5V OPEN 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose. The solid diamonds are the average of the measured data points for the samples
irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the
samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data
points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or
maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
144
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.68. Raw data for Positive Output Voltage 5V OPEN 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 5V OPEN 4 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
4.28E+00
4.27E+00
4.27E+00
4.27E+00
4.28E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
4.27E+00
Total
10
4.28E+00
4.27E+00
4.27E+00
4.27E+00
4.29E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.27E+00
Dose (krad(Si))
20
30
4.28E+00 4.29E+00
4.27E+00 4.28E+00
4.27E+00 4.28E+00
4.27E+00 4.28E+00
4.28E+00 4.31E+00
4.27E+00 4.27E+00
4.26E+00 4.27E+00
4.26E+00 4.27E+00
4.26E+00 4.27E+00
4.26E+00 4.27E+00
4.26E+00 4.27E+00
50
4.30E+00
4.30E+00
4.30E+00
4.30E+00
4.30E+00
4.29E+00
4.29E+00
4.29E+00
4.29E+00
4.29E+00
4.27E+00
24 Hr
Anneal
60
4.30E+00
4.31E+00
4.30E+00
4.30E+00
4.31E+00
4.29E+00
4.29E+00
4.29E+00
4.29E+00
4.29E+00
4.27E+00
168 Hr
Anneal
70
4.30E+00
4.31E+00
4.30E+00
4.30E+00
4.31E+00
4.30E+00
4.30E+00
4.30E+00
4.30E+00
4.30E+00
4.27E+00
4.27E+00 4.28E+00 4.27E+00 4.29E+00 4.30E+00 4.30E+00 4.30E+00
5.94E-03 4.97E-03 6.38E-03 1.07E-02 2.61E-03 2.51E-03 2.39E-03
4.29E+00 4.29E+00 4.29E+00 4.32E+00 4.31E+00 4.31E+00 4.31E+00
4.26E+00 4.26E+00 4.26E+00 4.26E+00 4.29E+00 4.30E+00 4.30E+00
4.27E+00
2.88E-03
4.28E+00
4.26E+00
4.00E+00
PASS
4.26E+00
1.52E-03
4.26E+00
4.26E+00
4.00E+00
PASS
4.26E+00
1.52E-03
4.27E+00
4.26E+00
4.00E+00
PASS
4.27E+00
1.48E-03
4.27E+00
4.27E+00
4.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
145
4.29E+00
1.79E-03
4.29E+00
4.28E+00
4.00E+00
PASS
4.29E+00
1.64E-03
4.29E+00
4.28E+00
4.00E+00
PASS
4.30E+00
1.10E-03
4.30E+00
4.30E+00
4.00E+00
PASS
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 5V 600 1 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
4.50E+00
4.00E+00
3.50E+00
3.00E+00
2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.69. Plot of Positive Output Voltage 5V 600 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
146
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.69. Raw data for Positive Output Voltage 5V 600 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
600Ω versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 5V 600 1 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
3.81E+00
3.83E+00
3.82E+00
3.80E+00
3.82E+00
3.83E+00
3.82E+00
3.82E+00
3.79E+00
3.80E+00
3.80E+00
Total
10
3.81E+00
3.82E+00
3.81E+00
3.79E+00
3.82E+00
3.82E+00
3.82E+00
3.82E+00
3.79E+00
3.80E+00
3.80E+00
Dose (krad(Si))
20
30
3.81E+00 3.81E+00
3.82E+00 3.82E+00
3.81E+00 3.81E+00
3.79E+00 3.79E+00
3.82E+00 3.82E+00
3.82E+00 3.82E+00
3.82E+00 3.82E+00
3.82E+00 3.82E+00
3.79E+00 3.79E+00
3.80E+00 3.80E+00
3.80E+00 3.80E+00
50
3.81E+00
3.82E+00
3.81E+00
3.79E+00
3.82E+00
3.82E+00
3.81E+00
3.82E+00
3.79E+00
3.79E+00
3.80E+00
24 Hr
Anneal
60
3.81E+00
3.82E+00
3.81E+00
3.79E+00
3.82E+00
3.82E+00
3.82E+00
3.82E+00
3.79E+00
3.80E+00
3.80E+00
168 Hr
Anneal
70
3.81E+00
3.82E+00
3.81E+00
3.79E+00
3.82E+00
3.82E+00
3.82E+00
3.82E+00
3.79E+00
3.80E+00
3.80E+00
3.81E+00 3.81E+00 3.81E+00 3.81E+00 3.81E+00 3.81E+00 3.81E+00
1.10E-02 1.05E-02 1.03E-02 1.05E-02 1.07E-02 1.11E-02 1.05E-02
3.84E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00
3.78E+00 3.78E+00 3.78E+00 3.78E+00 3.78E+00 3.78E+00 3.78E+00
3.81E+00
1.43E-02
3.85E+00
3.77E+00
3.40E+00
PASS
3.81E+00
1.47E-02
3.85E+00
3.77E+00
3.40E+00
PASS
3.81E+00
1.49E-02
3.85E+00
3.77E+00
3.20E+00
PASS
3.81E+00
1.51E-02
3.85E+00
3.77E+00
3.20E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
147
3.81E+00
1.49E-02
3.85E+00
3.77E+00
3.00E+00
PASS
3.81E+00
1.47E-02
3.85E+00
3.77E+00
3.00E+00
PASS
3.81E+00
1.45E-02
3.85E+00
3.77E+00
3.00E+00
PASS
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 5V 600 2 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
4.00E+00
3.50E+00
3.00E+00
2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.70. Plot of Positive Output Voltage 5V 600 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
148
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.70. Raw data for Positive Output Voltage 5V 600 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
600Ω versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 5V 600 2 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
3.79E+00
3.81E+00
3.80E+00
3.79E+00
3.81E+00
3.81E+00
3.80E+00
3.81E+00
3.79E+00
3.80E+00
3.79E+00
Total
10
3.79E+00
3.81E+00
3.79E+00
3.78E+00
3.81E+00
3.81E+00
3.80E+00
3.81E+00
3.79E+00
3.80E+00
3.79E+00
Dose (krad(Si))
20
30
3.78E+00 3.78E+00
3.80E+00 3.81E+00
3.79E+00 3.79E+00
3.78E+00 3.78E+00
3.80E+00 3.81E+00
3.81E+00 3.81E+00
3.80E+00 3.80E+00
3.81E+00 3.81E+00
3.78E+00 3.79E+00
3.80E+00 3.80E+00
3.79E+00 3.79E+00
50
3.78E+00
3.80E+00
3.79E+00
3.78E+00
3.80E+00
3.81E+00
3.80E+00
3.81E+00
3.78E+00
3.80E+00
3.79E+00
24 Hr
Anneal
60
3.78E+00
3.80E+00
3.79E+00
3.78E+00
3.80E+00
3.81E+00
3.80E+00
3.81E+00
3.78E+00
3.80E+00
3.79E+00
168 Hr
Anneal
70
3.78E+00
3.80E+00
3.79E+00
3.78E+00
3.80E+00
3.81E+00
3.80E+00
3.81E+00
3.79E+00
3.80E+00
3.79E+00
3.80E+00 3.79E+00 3.79E+00 3.79E+00 3.79E+00 3.79E+00 3.79E+00
1.14E-02 1.11E-02 1.11E-02 1.18E-02 1.21E-02 1.18E-02 1.18E-02
3.83E+00 3.83E+00 3.82E+00 3.83E+00 3.82E+00 3.82E+00 3.82E+00
3.77E+00 3.76E+00 3.76E+00 3.76E+00 3.76E+00 3.76E+00 3.76E+00
3.80E+00
9.09E-03
3.83E+00
3.78E+00
3.40E+00
PASS
3.80E+00
9.67E-03
3.83E+00
3.77E+00
3.40E+00
PASS
3.80E+00
9.92E-03
3.83E+00
3.77E+00
3.20E+00
PASS
3.80E+00
9.55E-03
3.83E+00
3.77E+00
3.20E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
149
3.80E+00
9.71E-03
3.82E+00
3.77E+00
3.00E+00
PASS
3.80E+00
9.88E-03
3.83E+00
3.77E+00
3.00E+00
PASS
3.80E+00
9.34E-03
3.82E+00
3.77E+00
3.00E+00
PASS
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 5V 600 3 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
4.50E+00
4.00E+00
3.50E+00
3.00E+00
2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.71. Plot of Positive Output Voltage 5V 600 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
150
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.71. Raw data for Positive Output Voltage 5V 600 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
600Ω versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 5V 600 3 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
3.80E+00
3.82E+00
3.81E+00
3.80E+00
3.82E+00
3.82E+00
3.81E+00
3.82E+00
3.80E+00
3.81E+00
3.80E+00
Total
10
3.80E+00
3.82E+00
3.80E+00
3.79E+00
3.82E+00
3.82E+00
3.81E+00
3.82E+00
3.80E+00
3.81E+00
3.80E+00
Dose (krad(Si))
20
30
3.79E+00 3.79E+00
3.82E+00 3.82E+00
3.80E+00 3.80E+00
3.79E+00 3.79E+00
3.82E+00 3.82E+00
3.82E+00 3.82E+00
3.81E+00 3.81E+00
3.82E+00 3.82E+00
3.79E+00 3.79E+00
3.81E+00 3.81E+00
3.80E+00 3.80E+00
50
3.79E+00
3.81E+00
3.80E+00
3.79E+00
3.81E+00
3.82E+00
3.81E+00
3.82E+00
3.79E+00
3.81E+00
3.80E+00
24 Hr
Anneal
60
3.79E+00
3.81E+00
3.80E+00
3.79E+00
3.81E+00
3.82E+00
3.81E+00
3.82E+00
3.79E+00
3.81E+00
3.80E+00
168 Hr
Anneal
70
3.79E+00
3.81E+00
3.80E+00
3.79E+00
3.81E+00
3.82E+00
3.81E+00
3.82E+00
3.79E+00
3.81E+00
3.80E+00
3.81E+00 3.80E+00 3.80E+00 3.80E+00 3.80E+00 3.80E+00 3.80E+00
1.19E-02 1.14E-02 1.16E-02 1.19E-02 1.21E-02 1.18E-02 1.16E-02
3.84E+00 3.84E+00 3.83E+00 3.84E+00 3.83E+00 3.83E+00 3.83E+00
3.78E+00 3.77E+00 3.77E+00 3.77E+00 3.77E+00 3.77E+00 3.77E+00
3.81E+00
1.03E-02
3.84E+00
3.78E+00
3.40E+00
PASS
3.81E+00
1.01E-02
3.84E+00
3.78E+00
3.40E+00
PASS
3.81E+00
1.03E-02
3.84E+00
3.78E+00
3.20E+00
PASS
3.81E+00
1.05E-02
3.84E+00
3.78E+00
3.20E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
151
3.81E+00
1.05E-02
3.84E+00
3.78E+00
3.00E+00
PASS
3.81E+00
1.07E-02
3.84E+00
3.78E+00
3.00E+00
PASS
3.81E+00
1.05E-02
3.84E+00
3.78E+00
3.00E+00
PASS
ELDRS Report
12-900 130307 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 5V 600 4 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
4.00E+00
3.50E+00
3.00E+00
2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.72. Plot of Positive Output Voltage 5V 600 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
152
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.72. Raw data for Positive Output Voltage 5V 600 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
600Ω versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage 5V 600 4 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Device
59
149
233
310
393
443
516
574
589
732
829
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
3.80E+00
3.81E+00
3.81E+00
3.79E+00
3.82E+00
3.81E+00
3.81E+00
3.81E+00
3.78E+00
3.79E+00
3.79E+00
Total
10
3.80E+00
3.81E+00
3.81E+00
3.79E+00
3.81E+00
3.81E+00
3.81E+00
3.81E+00
3.78E+00
3.79E+00
3.79E+00
Dose (krad(Si))
20
30
3.80E+00 3.80E+00
3.81E+00 3.81E+00
3.80E+00 3.80E+00
3.78E+00 3.78E+00
3.81E+00 3.81E+00
3.81E+00 3.81E+00
3.81E+00 3.81E+00
3.81E+00 3.81E+00
3.78E+00 3.78E+00
3.79E+00 3.79E+00
3.79E+00 3.79E+00
50
3.80E+00
3.80E+00
3.80E+00
3.78E+00
3.81E+00
3.81E+00
3.81E+00
3.81E+00
3.78E+00
3.78E+00
3.79E+00
24 Hr
Anneal
60
3.80E+00
3.81E+00
3.80E+00
3.78E+00
3.81E+00
3.81E+00
3.81E+00
3.81E+00
3.78E+00
3.79E+00
3.80E+00
168 Hr
Anneal
70
3.80E+00
3.81E+00
3.80E+00
3.78E+00
3.81E+00
3.81E+00
3.81E+00
3.81E+00
3.78E+00
3.79E+00
3.79E+00
3.81E+00 3.80E+00 3.80E+00 3.80E+00 3.80E+00 3.80E+00 3.80E+00
1.10E-02 1.06E-02 1.07E-02 1.12E-02 1.10E-02 1.12E-02 1.07E-02
3.84E+00 3.83E+00 3.83E+00 3.83E+00 3.83E+00 3.83E+00 3.83E+00
3.78E+00 3.77E+00 3.77E+00 3.77E+00 3.77E+00 3.77E+00 3.77E+00
3.80E+00
1.37E-02
3.84E+00
3.76E+00
3.40E+00
PASS
3.80E+00
1.42E-02
3.84E+00
3.76E+00
3.40E+00
PASS
3.80E+00
1.45E-02
3.84E+00
3.76E+00
3.20E+00
PASS
3.80E+00
1.44E-02
3.84E+00
3.76E+00
3.20E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
153
3.80E+00
1.49E-02
3.84E+00
3.76E+00
3.00E+00
PASS
3.80E+00
1.47E-02
3.84E+00
3.76E+00
3.00E+00
PASS
3.80E+00
1.44E-02
3.84E+00
3.76E+00
3.00E+00
PASS
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Output Voltage Low 5V OPEN 1 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Specification MAX
4.50E-02
4.00E-02
3.50E-02
3.00E-02
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.73. Plot of Output Voltage Low 5V OPEN 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
154
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.73. Raw data for Output Voltage Low 5V OPEN 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V OPEN 1 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Device
0
10
20
30
50
60
70
59 1.34E-02 1.36E-02 1.36E-02 1.38E-02 1.37E-02 1.38E-02 1.39E-02
149 1.38E-02 1.37E-02 1.36E-02 1.39E-02 1.39E-02 1.38E-02 1.39E-02
233 1.35E-02 1.35E-02 1.37E-02 1.37E-02 1.38E-02 1.37E-02 1.37E-02
310 1.36E-02 1.39E-02 1.36E-02 1.35E-02 1.37E-02 1.39E-02 1.36E-02
393 1.36E-02 1.37E-02 1.38E-02 1.37E-02 1.37E-02 1.39E-02 1.37E-02
443 1.38E-02 1.40E-02 1.38E-02 1.42E-02 1.41E-02 1.42E-02 1.41E-02
516 1.38E-02 1.35E-02 1.37E-02 1.42E-02 1.41E-02 1.41E-02 1.39E-02
574 1.40E-02 1.40E-02 1.39E-02 1.43E-02 1.41E-02 1.41E-02 1.41E-02
589 1.34E-02 1.37E-02 1.40E-02 1.40E-02 1.38E-02 1.39E-02 1.38E-02
732 1.36E-02 1.38E-02 1.37E-02 1.35E-02 1.39E-02 1.41E-02 1.38E-02
829 1.36E-02 1.32E-02 1.31E-02 1.37E-02 1.34E-02 1.36E-02 1.35E-02
Biased Statistics
Average Biased
1.36E-02 1.37E-02 1.37E-02 1.37E-02 1.38E-02 1.38E-02 1.38E-02
Std Dev Biased
1.48E-04 1.48E-04 8.94E-05 1.48E-04 8.94E-05 8.37E-05 1.34E-04
Ps90%/90% (+KTL) Biased
1.40E-02 1.41E-02 1.39E-02 1.41E-02 1.40E-02 1.40E-02 1.41E-02
Ps90%/90% (-KTL) Biased
1.32E-02 1.33E-02 1.34E-02 1.33E-02 1.35E-02 1.36E-02 1.34E-02
Un-Biased Statistics
Average Un-Biased
1.37E-02 1.38E-02 1.38E-02 1.40E-02 1.40E-02 1.41E-02 1.39E-02
Std Dev Un-Biased
2.28E-04 2.12E-04 1.30E-04 3.21E-04 1.41E-04 1.10E-04 1.52E-04
Ps90%/90% (+KTL) Un-Biased
1.43E-02 1.44E-02 1.42E-02 1.49E-02 1.44E-02 1.44E-02 1.44E-02
Ps90%/90% (-KTL) Un-Biased
1.31E-02 1.32E-02 1.35E-02 1.32E-02 1.36E-02 1.38E-02 1.35E-02
Specification MAX
2.50E-02 2.50E-02 3.00E-02 3.00E-02 4.00E-02 4.00E-02 4.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
155
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Output Voltage Low 5V OPEN 2 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Specification MAX
4.50E-02
4.00E-02
3.50E-02
3.00E-02
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.74. Plot of Output Voltage Low 5V OPEN 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
156
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.74. Raw data for Output Voltage Low 5V OPEN 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V OPEN 2 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Device
0
10
20
30
50
60
70
59 1.36E-02 1.36E-02 1.36E-02 1.38E-02 1.39E-02 1.38E-02 1.39E-02
149 1.42E-02 1.40E-02 1.37E-02 1.41E-02 1.40E-02 1.40E-02 1.42E-02
233 1.39E-02 1.35E-02 1.37E-02 1.39E-02 1.38E-02 1.37E-02 1.38E-02
310 1.36E-02 1.35E-02 1.36E-02 1.38E-02 1.39E-02 1.39E-02 1.39E-02
393 1.34E-02 1.37E-02 1.40E-02 1.39E-02 1.39E-02 1.38E-02 1.39E-02
443 1.42E-02 1.39E-02 1.40E-02 1.43E-02 1.42E-02 1.42E-02 1.41E-02
516 1.37E-02 1.39E-02 1.36E-02 1.40E-02 1.41E-02 1.40E-02 1.40E-02
574 1.39E-02 1.40E-02 1.38E-02 1.41E-02 1.41E-02 1.43E-02 1.39E-02
589 1.36E-02 1.37E-02 1.39E-02 1.39E-02 1.41E-02 1.41E-02 1.39E-02
732 1.35E-02 1.39E-02 1.38E-02 1.41E-02 1.39E-02 1.40E-02 1.38E-02
829 1.37E-02 1.41E-02 1.38E-02 1.36E-02 1.37E-02 1.37E-02 1.36E-02
Biased Statistics
Average Biased
1.37E-02 1.37E-02 1.37E-02 1.39E-02 1.39E-02 1.38E-02 1.39E-02
Std Dev Biased
3.13E-04 2.07E-04 1.64E-04 1.22E-04 7.07E-05 1.14E-04 1.52E-04
Ps90%/90% (+KTL) Biased
1.46E-02 1.42E-02 1.42E-02 1.42E-02 1.41E-02 1.42E-02 1.44E-02
Ps90%/90% (-KTL) Biased
1.29E-02 1.31E-02 1.33E-02 1.36E-02 1.37E-02 1.35E-02 1.35E-02
Un-Biased Statistics
Average Un-Biased
1.38E-02 1.39E-02 1.38E-02 1.41E-02 1.41E-02 1.41E-02 1.39E-02
Std Dev Un-Biased
2.77E-04 1.10E-04 1.48E-04 1.48E-04 1.10E-04 1.30E-04 1.14E-04
Ps90%/90% (+KTL) Un-Biased
1.45E-02 1.42E-02 1.42E-02 1.45E-02 1.44E-02 1.45E-02 1.43E-02
Ps90%/90% (-KTL) Un-Biased
1.30E-02 1.36E-02 1.34E-02 1.37E-02 1.38E-02 1.38E-02 1.36E-02
Specification MAX
2.50E-02 2.50E-02 3.00E-02 3.00E-02 4.00E-02 4.00E-02 4.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
157
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Output Voltage Low 5V OPEN 3 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Specification MAX
4.50E-02
4.00E-02
3.50E-02
3.00E-02
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.75. Plot of Output Voltage Low 5V OPEN 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
158
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.75. Raw data for Output Voltage Low 5V OPEN 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V OPEN 3 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Device
0
10
20
30
50
60
70
59 1.39E-02 1.40E-02 1.38E-02 1.35E-02 1.39E-02 1.38E-02 1.38E-02
149 1.37E-02 1.40E-02 1.38E-02 1.38E-02 1.39E-02 1.40E-02 1.39E-02
233 1.37E-02 1.37E-02 1.37E-02 1.37E-02 1.37E-02 1.38E-02 1.38E-02
310 1.37E-02 1.34E-02 1.37E-02 1.35E-02 1.37E-02 1.38E-02 1.37E-02
393 1.39E-02 1.39E-02 1.38E-02 1.38E-02 1.36E-02 1.37E-02 1.38E-02
443 1.36E-02 1.41E-02 1.40E-02 1.39E-02 1.41E-02 1.41E-02 1.41E-02
516 1.36E-02 1.39E-02 1.37E-02 1.40E-02 1.40E-02 1.40E-02 1.38E-02
574 1.38E-02 1.39E-02 1.39E-02 1.42E-02 1.41E-02 1.41E-02 1.40E-02
589 1.40E-02 1.34E-02 1.38E-02 1.39E-02 1.40E-02 1.40E-02 1.36E-02
732 1.39E-02 1.39E-02 1.39E-02 1.39E-02 1.41E-02 1.41E-02 1.39E-02
829 1.36E-02 1.35E-02 1.39E-02 1.37E-02 1.36E-02 1.34E-02 1.36E-02
Biased Statistics
Average Biased
1.38E-02 1.38E-02 1.38E-02 1.37E-02 1.38E-02 1.38E-02 1.38E-02
Std Dev Biased
1.10E-04 2.55E-04 5.48E-05 1.52E-04 1.34E-04 1.10E-04 7.07E-05
Ps90%/90% (+KTL) Biased
1.41E-02 1.45E-02 1.39E-02 1.41E-02 1.41E-02 1.41E-02 1.40E-02
Ps90%/90% (-KTL) Biased
1.35E-02 1.31E-02 1.36E-02 1.32E-02 1.34E-02 1.35E-02 1.36E-02
Un-Biased Statistics
Average Un-Biased
1.38E-02 1.38E-02 1.39E-02 1.40E-02 1.41E-02 1.41E-02 1.39E-02
Std Dev Un-Biased
1.79E-04 2.61E-04 1.14E-04 1.30E-04 5.48E-05 5.48E-05 1.92E-04
Ps90%/90% (+KTL) Un-Biased
1.43E-02 1.46E-02 1.42E-02 1.43E-02 1.42E-02 1.42E-02 1.44E-02
Ps90%/90% (-KTL) Un-Biased
1.33E-02 1.31E-02 1.35E-02 1.36E-02 1.39E-02 1.39E-02 1.34E-02
Specification MAX
2.50E-02 2.50E-02 3.00E-02 3.00E-02 4.00E-02 4.00E-02 4.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
159
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Output Voltage Low 5V OPEN 4 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Specification MAX
4.50E-02
4.00E-02
3.50E-02
3.00E-02
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.76. Plot of Output Voltage Low 5V OPEN 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
160
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.76. Raw data for Output Voltage Low 5V OPEN 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL=
OPEN versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V OPEN 4 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Device
0
10
20
30
50
60
70
59 1.38E-02 1.37E-02 1.42E-02 1.35E-02 1.38E-02 1.38E-02 1.40E-02
149 1.39E-02 1.40E-02 1.40E-02 1.39E-02 1.39E-02 1.40E-02 1.39E-02
233 1.38E-02 1.37E-02 1.37E-02 1.37E-02 1.39E-02 1.39E-02 1.39E-02
310 1.42E-02 1.41E-02 1.36E-02 1.38E-02 1.38E-02 1.38E-02 1.38E-02
393 1.38E-02 1.40E-02 1.40E-02 1.41E-02 1.40E-02 1.40E-02 1.40E-02
443 1.41E-02 1.41E-02 1.40E-02 1.40E-02 1.43E-02 1.43E-02 1.40E-02
516 1.38E-02 1.39E-02 1.41E-02 1.40E-02 1.41E-02 1.41E-02 1.39E-02
574 1.41E-02 1.39E-02 1.40E-02 1.41E-02 1.42E-02 1.41E-02 1.41E-02
589 1.35E-02 1.38E-02 1.38E-02 1.39E-02 1.40E-02 1.42E-02 1.39E-02
732 1.36E-02 1.38E-02 1.40E-02 1.41E-02 1.41E-02 1.40E-02 1.38E-02
829 1.37E-02 1.36E-02 1.38E-02 1.36E-02 1.36E-02 1.37E-02 1.37E-02
Biased Statistics
Average Biased
1.39E-02 1.39E-02 1.39E-02 1.38E-02 1.39E-02 1.39E-02 1.39E-02
Std Dev Biased
1.73E-04 1.87E-04 2.45E-04 2.24E-04 8.37E-05 1.00E-04 8.37E-05
Ps90%/90% (+KTL) Biased
1.44E-02 1.44E-02 1.46E-02 1.44E-02 1.41E-02 1.42E-02 1.41E-02
Ps90%/90% (-KTL) Biased
1.34E-02 1.34E-02 1.32E-02 1.32E-02 1.37E-02 1.36E-02 1.37E-02
Un-Biased Statistics
Average Un-Biased
1.38E-02 1.39E-02 1.40E-02 1.40E-02 1.41E-02 1.41E-02 1.39E-02
Std Dev Un-Biased
2.77E-04 1.22E-04 1.10E-04 8.37E-05 1.14E-04 1.14E-04 1.14E-04
Ps90%/90% (+KTL) Un-Biased
1.46E-02 1.42E-02 1.43E-02 1.42E-02 1.45E-02 1.45E-02 1.43E-02
Ps90%/90% (-KTL) Un-Biased
1.31E-02 1.36E-02 1.37E-02 1.38E-02 1.38E-02 1.38E-02 1.36E-02
Specification MAX
2.50E-02 2.50E-02 3.00E-02 3.00E-02 4.00E-02 4.00E-02 4.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
161
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Low 5V 600 1 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.77. Plot of Output Voltage Low 5V 600 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
162
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.77. Raw data for Output Voltage Low 5V 600 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V 600 1 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
0
10
20
30
50
60
70
Device
59 6.00E-03 5.80E-03 5.80E-03 5.70E-03 5.50E-03 5.60E-03 5.50E-03
149 6.20E-03 6.40E-03 6.10E-03 5.90E-03 5.70E-03 5.50E-03 5.60E-03
233 6.00E-03 5.60E-03 5.80E-03 6.10E-03 5.60E-03 5.70E-03 5.50E-03
310 6.00E-03 6.00E-03 6.00E-03 5.90E-03 5.70E-03 5.60E-03 5.50E-03
393 6.20E-03 6.20E-03 6.00E-03 5.80E-03 5.60E-03 5.60E-03 5.50E-03
443 5.90E-03 6.10E-03 6.10E-03 6.00E-03 5.80E-03 5.80E-03 5.80E-03
516 6.00E-03 6.00E-03 6.20E-03 6.20E-03 5.80E-03 5.90E-03 5.80E-03
574 5.70E-03 6.10E-03 6.10E-03 6.00E-03 5.80E-03 5.90E-03 5.80E-03
589 6.40E-03 5.90E-03 5.90E-03 6.10E-03 5.80E-03 5.70E-03 5.80E-03
732 6.20E-03 6.10E-03 5.70E-03 6.00E-03 5.70E-03 5.70E-03 5.80E-03
829 6.10E-03 6.00E-03 6.10E-03 5.90E-03 5.80E-03 5.90E-03 5.90E-03
Biased Statistics
Average Biased
6.08E-03 6.00E-03 5.94E-03 5.88E-03 5.62E-03 5.60E-03 5.52E-03
Std Dev Biased
1.10E-04 3.16E-04 1.34E-04 1.48E-04 8.37E-05 7.07E-05 4.47E-05
Ps90%/90% (+KTL) Biased
6.38E-03 6.87E-03 6.31E-03 6.29E-03 5.85E-03 5.79E-03 5.64E-03
Ps90%/90% (-KTL) Biased
5.78E-03 5.13E-03 5.57E-03 5.47E-03 5.39E-03 5.41E-03 5.40E-03
Un-Biased Statistics
Average Un-Biased
6.04E-03 6.04E-03 6.00E-03 6.06E-03 5.78E-03 5.80E-03 5.80E-03
Std Dev Un-Biased
2.70E-04 8.94E-05 2.00E-04 8.94E-05 4.47E-05 1.00E-04 0.00E+00
Ps90%/90% (+KTL) Un-Biased
6.78E-03 6.29E-03 6.55E-03 6.31E-03 5.90E-03 6.07E-03 5.80E-03
Ps90%/90% (-KTL) Un-Biased
5.30E-03 5.79E-03 5.45E-03 5.81E-03 5.66E-03 5.53E-03 5.80E-03
Specification MAX
1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
163
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Low 5V 600 2 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.78. Plot of Output Voltage Low 5V 600 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
164
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.78. Raw data for Output Voltage Low 5V 600 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V 600 2 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
0
10
20
30
50
60
70
Device
59 6.00E-03 5.70E-03 5.80E-03 5.80E-03 5.50E-03 5.40E-03 5.20E-03
149 6.30E-03 5.80E-03 5.70E-03 6.00E-03 5.50E-03 5.60E-03 5.50E-03
233 5.90E-03 5.70E-03 5.60E-03 5.80E-03 5.50E-03 5.40E-03 5.30E-03
310 5.70E-03 6.00E-03 5.80E-03 5.50E-03 5.40E-03 5.50E-03 5.30E-03
393 5.70E-03 5.90E-03 5.80E-03 5.90E-03 5.40E-03 5.50E-03 5.50E-03
443 6.10E-03 6.10E-03 5.70E-03 6.10E-03 5.80E-03 5.70E-03 5.70E-03
516 5.70E-03 6.00E-03 6.10E-03 5.80E-03 5.60E-03 5.70E-03 5.60E-03
574 6.10E-03 6.00E-03 5.90E-03 6.00E-03 5.60E-03 5.60E-03 5.70E-03
589 5.90E-03 5.70E-03 5.50E-03 5.90E-03 5.70E-03 5.60E-03 5.60E-03
732 6.10E-03 6.10E-03 5.70E-03 5.70E-03 5.60E-03 5.70E-03 5.60E-03
829 5.80E-03 6.20E-03 5.50E-03 5.60E-03 5.60E-03 5.60E-03 5.70E-03
Biased Statistics
Average Biased
5.92E-03 5.82E-03 5.74E-03 5.80E-03 5.46E-03 5.48E-03 5.36E-03
Std Dev Biased
2.49E-04 1.30E-04 8.94E-05 1.87E-04 5.48E-05 8.37E-05 1.34E-04
Ps90%/90% (+KTL) Biased
6.60E-03 6.18E-03 5.99E-03 6.31E-03 5.61E-03 5.71E-03 5.73E-03
Ps90%/90% (-KTL) Biased
5.24E-03 5.46E-03 5.49E-03 5.29E-03 5.31E-03 5.25E-03 4.99E-03
Un-Biased Statistics
Average Un-Biased
5.98E-03 5.98E-03 5.78E-03 5.90E-03 5.66E-03 5.66E-03 5.64E-03
Std Dev Un-Biased
1.79E-04 1.64E-04 2.28E-04 1.58E-04 8.94E-05 5.48E-05 5.48E-05
Ps90%/90% (+KTL) Un-Biased
6.47E-03 6.43E-03 6.41E-03 6.33E-03 5.91E-03 5.81E-03 5.79E-03
Ps90%/90% (-KTL) Un-Biased
5.49E-03 5.53E-03 5.15E-03 5.47E-03 5.41E-03 5.51E-03 5.49E-03
Specification MAX
1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
165
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Low 5V 600 3 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.79. Plot of Output Voltage Low 5V 600 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
166
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.79. Raw data for Output Voltage Low 5V 600 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V 600 3 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
0
10
20
30
50
60
70
Device
59 6.10E-03 6.00E-03 5.90E-03 5.90E-03 5.60E-03 5.50E-03 5.60E-03
149 6.20E-03 6.20E-03 5.90E-03 6.10E-03 5.60E-03 5.70E-03 5.70E-03
233 6.20E-03 6.10E-03 5.90E-03 5.90E-03 5.80E-03 5.60E-03 5.60E-03
310 6.00E-03 5.90E-03 6.00E-03 6.00E-03 5.60E-03 5.60E-03 5.50E-03
393 6.10E-03 6.10E-03 6.20E-03 6.20E-03 5.70E-03 5.70E-03 5.50E-03
443 6.00E-03 6.40E-03 6.20E-03 6.40E-03 6.00E-03 6.00E-03 5.80E-03
516 6.10E-03 5.70E-03 6.10E-03 6.20E-03 5.80E-03 5.80E-03 5.80E-03
574 6.00E-03 6.60E-03 6.30E-03 6.00E-03 5.90E-03 6.00E-03 6.00E-03
589 5.90E-03 5.80E-03 6.10E-03 6.10E-03 5.80E-03 5.90E-03 5.80E-03
732 6.00E-03 6.00E-03 6.10E-03 6.10E-03 5.80E-03 6.00E-03 5.80E-03
829 6.00E-03 6.20E-03 5.80E-03 5.80E-03 5.90E-03 6.00E-03 5.90E-03
Biased Statistics
Average Biased
6.12E-03 6.06E-03 5.98E-03 6.02E-03 5.66E-03 5.62E-03 5.58E-03
Std Dev Biased
8.37E-05 1.14E-04 1.30E-04 1.30E-04 8.94E-05 8.37E-05 8.37E-05
Ps90%/90% (+KTL) Biased
6.35E-03 6.37E-03 6.34E-03 6.38E-03 5.91E-03 5.85E-03 5.81E-03
Ps90%/90% (-KTL) Biased
5.89E-03 5.75E-03 5.62E-03 5.66E-03 5.41E-03 5.39E-03 5.35E-03
Un-Biased Statistics
Average Un-Biased
6.00E-03 6.10E-03 6.16E-03 6.16E-03 5.86E-03 5.94E-03 5.84E-03
Std Dev Un-Biased
7.07E-05 3.87E-04 8.94E-05 1.52E-04 8.94E-05 8.94E-05 8.94E-05
Ps90%/90% (+KTL) Un-Biased
6.19E-03 7.16E-03 6.41E-03 6.58E-03 6.11E-03 6.19E-03 6.09E-03
Ps90%/90% (-KTL) Un-Biased
5.81E-03 5.04E-03 5.91E-03 5.74E-03 5.61E-03 5.69E-03 5.59E-03
Specification MAX
1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
167
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Low 5V 600 4 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.80. Plot of Output Voltage Low 5V 600 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
168
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.80. Raw data for Output Voltage Low 5V 600 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V 600 4 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
0
10
20
30
50
60
70
Device
59 5.90E-03 5.80E-03 5.80E-03 5.90E-03 5.40E-03 5.40E-03 5.40E-03
149 5.90E-03 6.00E-03 6.10E-03 5.90E-03 5.50E-03 5.60E-03 5.40E-03
233 6.00E-03 6.10E-03 5.90E-03 5.90E-03 5.60E-03 5.50E-03 5.40E-03
310 6.10E-03 5.80E-03 5.60E-03 6.00E-03 5.50E-03 5.40E-03 5.30E-03
393 6.10E-03 6.10E-03 6.00E-03 5.70E-03 5.50E-03 5.50E-03 5.60E-03
443 6.20E-03 6.00E-03 5.80E-03 5.90E-03 5.70E-03 5.80E-03 5.70E-03
516 6.00E-03 6.30E-03 6.00E-03 6.00E-03 5.70E-03 5.70E-03 5.70E-03
574 5.60E-03 5.80E-03 6.10E-03 6.10E-03 5.70E-03 5.70E-03 5.70E-03
589 5.40E-03 6.00E-03 5.80E-03 5.90E-03 5.50E-03 5.70E-03 5.60E-03
732 5.90E-03 6.20E-03 6.00E-03 5.70E-03 5.60E-03 5.60E-03 5.60E-03
829 5.60E-03 5.90E-03 5.90E-03 6.00E-03 5.80E-03 5.70E-03 5.60E-03
Biased Statistics
Average Biased
6.00E-03 5.96E-03 5.88E-03 5.88E-03 5.50E-03 5.48E-03 5.42E-03
Std Dev Biased
1.00E-04 1.52E-04 1.92E-04 1.10E-04 7.07E-05 8.37E-05 1.10E-04
Ps90%/90% (+KTL) Biased
6.27E-03 6.38E-03 6.41E-03 6.18E-03 5.69E-03 5.71E-03 5.72E-03
Ps90%/90% (-KTL) Biased
5.73E-03 5.54E-03 5.35E-03 5.58E-03 5.31E-03 5.25E-03 5.12E-03
Un-Biased Statistics
Average Un-Biased
5.82E-03 6.06E-03 5.94E-03 5.92E-03 5.64E-03 5.70E-03 5.66E-03
Std Dev Un-Biased
3.19E-04 1.95E-04 1.34E-04 1.48E-04 8.94E-05 7.07E-05 5.48E-05
Ps90%/90% (+KTL) Un-Biased
6.70E-03 6.59E-03 6.31E-03 6.33E-03 5.89E-03 5.89E-03 5.81E-03
Ps90%/90% (-KTL) Un-Biased
4.94E-03 5.53E-03 5.57E-03 5.51E-03 5.39E-03 5.51E-03 5.51E-03
Specification MAX
1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
169
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Output Voltage Low 5V 1mA 1 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
Specification MAX
1.20E+00
1.00E+00
8.00E-01
6.00E-01
4.00E-01
2.00E-01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.81. Plot of Output Voltage Low 5V 1mA 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
170
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.81. Raw data for Output Voltage Low 5V 1mA 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK=
1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V 1mA 1 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
0
10
20
30
50
60
70
Device
59 2.42E-01 2.39E-01 2.42E-01 2.43E-01 2.48E-01 2.48E-01 2.51E-01
149 2.39E-01 2.37E-01 2.41E-01 2.40E-01 2.45E-01 2.46E-01 2.48E-01
233 2.38E-01 2.38E-01 2.40E-01 2.40E-01 2.45E-01 2.45E-01 2.49E-01
310 2.44E-01 2.43E-01 2.47E-01 2.46E-01 2.51E-01 2.51E-01 2.55E-01
393 2.38E-01 2.39E-01 2.42E-01 2.41E-01 2.47E-01 2.48E-01 2.50E-01
443 2.39E-01 2.37E-01 2.42E-01 2.40E-01 2.43E-01 2.43E-01 2.44E-01
516 2.37E-01 2.34E-01 2.39E-01 2.37E-01 2.41E-01 2.41E-01 2.42E-01
574 2.38E-01 2.35E-01 2.39E-01 2.38E-01 2.41E-01 2.42E-01 2.42E-01
589 2.43E-01 2.40E-01 2.45E-01 2.43E-01 2.46E-01 2.47E-01 2.48E-01
732 2.42E-01 2.39E-01 2.43E-01 2.42E-01 2.46E-01 2.46E-01 2.47E-01
829 2.40E-01 2.39E-01 2.43E-01 2.40E-01 2.40E-01 2.40E-01 2.40E-01
Biased Statistics
Average Biased
2.40E-01 2.39E-01 2.42E-01 2.42E-01 2.47E-01 2.48E-01 2.51E-01
Std Dev Biased
2.68E-03 2.28E-03 2.70E-03 2.55E-03 2.49E-03 2.30E-03 2.70E-03
Ps90%/90% (+KTL) Biased
2.48E-01 2.45E-01 2.50E-01 2.49E-01 2.54E-01 2.54E-01 2.58E-01
Ps90%/90% (-KTL) Biased
2.33E-01 2.33E-01 2.35E-01 2.35E-01 2.40E-01 2.41E-01 2.43E-01
Un-Biased Statistics
Average Un-Biased
2.40E-01 2.37E-01 2.42E-01 2.40E-01 2.43E-01 2.44E-01 2.45E-01
Std Dev Un-Biased
2.59E-03 2.55E-03 2.61E-03 2.55E-03 2.51E-03 2.59E-03 2.79E-03
Ps90%/90% (+KTL) Un-Biased
2.47E-01 2.44E-01 2.49E-01 2.47E-01 2.50E-01 2.51E-01 2.52E-01
Ps90%/90% (-KTL) Un-Biased
2.33E-01 2.30E-01 2.34E-01 2.33E-01 2.37E-01 2.37E-01 2.37E-01
Specification MAX
3.50E-01 6.00E-01 8.00E-01 8.00E-01 1.00E+00 1.00E+00 1.00E+00
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
171
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Output Voltage Low 5V 1mA 2 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
Specification MAX
1.20E+00
1.00E+00
8.00E-01
6.00E-01
4.00E-01
2.00E-01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.82. Plot of Output Voltage Low 5V 1mA 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
172
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.82. Raw data for Output Voltage Low 5V 1mA 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK=
1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V 1mA 2 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
0
10
20
30
50
60
70
Device
59 2.52E-01 2.51E-01 2.54E-01 2.52E-01 2.59E-01 2.60E-01 2.64E-01
149 2.46E-01 2.46E-01 2.48E-01 2.48E-01 2.54E-01 2.55E-01 2.57E-01
233 2.45E-01 2.47E-01 2.50E-01 2.49E-01 2.56E-01 2.57E-01 2.60E-01
310 2.50E-01 2.51E-01 2.54E-01 2.53E-01 2.59E-01 2.60E-01 2.63E-01
393 2.44E-01 2.45E-01 2.48E-01 2.48E-01 2.54E-01 2.55E-01 2.58E-01
443 2.44E-01 2.42E-01 2.47E-01 2.45E-01 2.48E-01 2.48E-01 2.50E-01
516 2.46E-01 2.43E-01 2.47E-01 2.46E-01 2.50E-01 2.50E-01 2.51E-01
574 2.46E-01 2.43E-01 2.47E-01 2.45E-01 2.49E-01 2.50E-01 2.50E-01
589 2.47E-01 2.44E-01 2.49E-01 2.47E-01 2.51E-01 2.52E-01 2.53E-01
732 2.44E-01 2.42E-01 2.46E-01 2.45E-01 2.48E-01 2.49E-01 2.50E-01
829 2.47E-01 2.45E-01 2.48E-01 2.46E-01 2.45E-01 2.46E-01 2.46E-01
Biased Statistics
Average Biased
2.47E-01 2.48E-01 2.51E-01 2.50E-01 2.56E-01 2.57E-01 2.60E-01
Std Dev Biased
3.44E-03 2.83E-03 3.03E-03 2.35E-03 2.51E-03 2.51E-03 3.05E-03
Ps90%/90% (+KTL) Biased
2.57E-01 2.56E-01 2.59E-01 2.56E-01 2.63E-01 2.64E-01 2.69E-01
Ps90%/90% (-KTL) Biased
2.38E-01 2.40E-01 2.42E-01 2.44E-01 2.50E-01 2.51E-01 2.52E-01
Un-Biased Statistics
Average Un-Biased
2.45E-01 2.43E-01 2.47E-01 2.46E-01 2.49E-01 2.50E-01 2.51E-01
Std Dev Un-Biased
1.34E-03 8.37E-04 1.10E-03 8.94E-04 1.30E-03 1.48E-03 1.30E-03
Ps90%/90% (+KTL) Un-Biased
2.49E-01 2.45E-01 2.50E-01 2.48E-01 2.53E-01 2.54E-01 2.54E-01
Ps90%/90% (-KTL) Un-Biased
2.42E-01 2.41E-01 2.44E-01 2.43E-01 2.46E-01 2.46E-01 2.47E-01
Specification MAX
3.50E-01 6.00E-01 8.00E-01 8.00E-01 1.00E+00 1.00E+00 1.00E+00
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
173
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Output Voltage Low 5V 1mA 3 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
Specification MAX
1.20E+00
1.00E+00
8.00E-01
6.00E-01
4.00E-01
2.00E-01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.83. Plot of Output Voltage Low 5V 1mA 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
174
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.83. Raw data for Output Voltage Low 5V 1mA 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK=
1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V 1mA 3 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
0
10
20
30
50
60
70
Device
59 2.46E-01 2.45E-01 2.47E-01 2.47E-01 2.52E-01 2.53E-01 2.56E-01
149 2.42E-01 2.41E-01 2.44E-01 2.43E-01 2.48E-01 2.49E-01 2.51E-01
233 2.40E-01 2.41E-01 2.43E-01 2.43E-01 2.48E-01 2.49E-01 2.52E-01
310 2.43E-01 2.44E-01 2.47E-01 2.46E-01 2.51E-01 2.52E-01 2.55E-01
393 2.38E-01 2.39E-01 2.42E-01 2.40E-01 2.46E-01 2.47E-01 2.49E-01
443 2.40E-01 2.37E-01 2.42E-01 2.39E-01 2.43E-01 2.44E-01 2.44E-01
516 2.41E-01 2.38E-01 2.42E-01 2.41E-01 2.44E-01 2.44E-01 2.45E-01
574 2.41E-01 2.38E-01 2.42E-01 2.40E-01 2.44E-01 2.44E-01 2.45E-01
589 2.41E-01 2.39E-01 2.44E-01 2.42E-01 2.45E-01 2.46E-01 2.46E-01
732 2.40E-01 2.38E-01 2.42E-01 2.40E-01 2.43E-01 2.43E-01 2.44E-01
829 2.40E-01 2.40E-01 2.42E-01 2.40E-01 2.40E-01 2.40E-01 2.40E-01
Biased Statistics
Average Biased
2.42E-01 2.42E-01 2.45E-01 2.44E-01 2.49E-01 2.50E-01 2.53E-01
Std Dev Biased
3.03E-03 2.45E-03 2.30E-03 2.77E-03 2.45E-03 2.45E-03 2.88E-03
Ps90%/90% (+KTL) Biased
2.50E-01 2.49E-01 2.51E-01 2.51E-01 2.56E-01 2.57E-01 2.60E-01
Ps90%/90% (-KTL) Biased
2.33E-01 2.35E-01 2.38E-01 2.36E-01 2.42E-01 2.43E-01 2.45E-01
Un-Biased Statistics
Average Un-Biased
2.41E-01 2.38E-01 2.42E-01 2.40E-01 2.44E-01 2.44E-01 2.45E-01
Std Dev Un-Biased
5.48E-04 7.07E-04 8.94E-04 1.14E-03 8.37E-04 1.10E-03 8.37E-04
Ps90%/90% (+KTL) Un-Biased
2.42E-01 2.40E-01 2.45E-01 2.44E-01 2.46E-01 2.47E-01 2.47E-01
Ps90%/90% (-KTL) Un-Biased
2.39E-01 2.36E-01 2.40E-01 2.37E-01 2.42E-01 2.41E-01 2.43E-01
Specification MAX
3.50E-01 6.00E-01 8.00E-01 8.00E-01 1.00E+00 1.00E+00 1.00E+00
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
175
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Output Voltage Low 5V 1mA 4 (V)
@ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
Specification MAX
1.20E+00
1.00E+00
8.00E-01
6.00E-01
4.00E-01
2.00E-01
0.00E+00
0
10
20
30
40
Total Dose (krad(Si))
50
2460
Hr
Anneal
16870Hr
Anneal
Figure 5.84. Plot of Output Voltage Low 5V 1mA 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the
unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
176
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.84. Raw data for Output Voltage Low 5V 1mA 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK=
1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Low 5V 1mA 4 (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
0
10
20
30
50
60
70
Device
59 2.48E-01 2.45E-01 2.49E-01 2.48E-01 2.56E-01 2.57E-01 2.60E-01
149 2.44E-01 2.42E-01 2.45E-01 2.46E-01 2.52E-01 2.52E-01 2.55E-01
233 2.43E-01 2.43E-01 2.45E-01 2.45E-01 2.51E-01 2.51E-01 2.55E-01
310 2.49E-01 2.50E-01 2.53E-01 2.53E-01 2.59E-01 2.59E-01 2.63E-01
393 2.45E-01 2.45E-01 2.48E-01 2.48E-01 2.56E-01 2.56E-01 2.59E-01
443 2.43E-01 2.42E-01 2.47E-01 2.45E-01 2.48E-01 2.48E-01 2.50E-01
516 2.42E-01 2.39E-01 2.43E-01 2.42E-01 2.46E-01 2.46E-01 2.47E-01
574 2.43E-01 2.39E-01 2.43E-01 2.43E-01 2.46E-01 2.46E-01 2.47E-01
589 2.48E-01 2.45E-01 2.50E-01 2.48E-01 2.52E-01 2.53E-01 2.54E-01
732 2.47E-01 2.45E-01 2.50E-01 2.48E-01 2.52E-01 2.52E-01 2.54E-01
829 2.46E-01 2.45E-01 2.48E-01 2.46E-01 2.45E-01 2.46E-01 2.46E-01
Biased Statistics
Average Biased
2.46E-01 2.45E-01 2.48E-01 2.48E-01 2.55E-01 2.55E-01 2.58E-01
Std Dev Biased
2.59E-03 3.08E-03 3.32E-03 3.08E-03 3.27E-03 3.39E-03 3.44E-03
Ps90%/90% (+KTL) Biased
2.53E-01 2.53E-01 2.57E-01 2.56E-01 2.64E-01 2.64E-01 2.68E-01
Ps90%/90% (-KTL) Biased
2.39E-01 2.37E-01 2.39E-01 2.40E-01 2.46E-01 2.46E-01 2.49E-01
Un-Biased Statistics
Average Un-Biased
2.45E-01 2.42E-01 2.47E-01 2.45E-01 2.49E-01 2.49E-01 2.50E-01
Std Dev Un-Biased
2.70E-03 3.00E-03 3.51E-03 2.77E-03 3.03E-03 3.32E-03 3.51E-03
Ps90%/90% (+KTL) Un-Biased
2.52E-01 2.50E-01 2.56E-01 2.53E-01 2.57E-01 2.58E-01 2.60E-01
Ps90%/90% (-KTL) Un-Biased
2.37E-01 2.34E-01 2.37E-01 2.38E-01 2.40E-01 2.40E-01 2.41E-01
Specification MAX
3.50E-01 6.00E-01 8.00E-01 8.00E-01 1.00E+00 1.00E+00 1.00E+00
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
177
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
6.0. Summary / Conclusions
The low dose rate testing described in this final report was performed using the facilities at Aeroflex
RAD's Longmire Laboratories in Colorado Springs, CO. The low dose rate source is a GB-150 irradiator
modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily
shielded by lead. During the irradiation exposures the rod is raised by an electronic timer/controller and
the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from
approximately 1mrad(Si)/s to a maximum of approximately 50rad(Si)/s, determined by the distance
from the source.
The parametric data was obtained as "read and record" and all the raw data plus an attributes summary
are contained in this report as well as in a separate Excel file. The attributes data contains the average,
standard deviation and the average with the KTL values applied. The KTL value used in this work is
2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The
90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535
sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the
following criteria must be met for a device to pass the low dose rate test: following the radiation
exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units
irradiated without electrical bias and the KTL statistics are included in this report for reference only. If
any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet
specification limits, then the lot could be logged as a failure.
Based on this criterion the RH1014MW Quad Precision Operational Amplifier (from the lot traceability
information provided on the first page of this test report) PASSED the enhanced low dose rate
sensitivity test to the maximum tested dose level of 50krad(Si) with all parameters remaining within
their datasheet specifications.
An ISO 9001:2008 and DSCC Certified Company
178
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix A: Photograph of Packing Label and a Sample Unit-Under-Test to Show Part
Traceability
An ISO 9001:2008 and DSCC Certified Company
179
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix B: Radiation Bias Connections and Absolute Maximum Ratings
ELDRS Radiation Biased Conditions: Extracted from Linear Technology RH1014M Quad Precision
Operational Amplifier Datasheet Revision G.
An ISO 9001:2008 and DSCC Certified Company
180
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Figure B.1. Irradiation bias circuit. This figure was extracted from Linear Technology RH1014M Quad
Precision Operational Amplifier Datasheet Revision G.
Figure B.2. Package drawing (for reference only). This figure was extracted from Linear Technology RH1014M
Quad Precision Operational Amplifier Datasheet Revision G.
An ISO 9001:2008 and DSCC Certified Company
181
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
ELDRS Radiation Unbiased Conditions: All pins grounded.
Absolute Maximum Ratings:
Parameter
Supply Voltage
Max Rating
±22V
Differential Input Voltage
±30V
Equal to Positive Supply Voltage,
Input Voltage
5V Below Negative Supply Voltage
Output Short-Circuit Duration Indefinite
An ISO 9001:2008 and DSCC Certified Company
182
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix C: Electrical Test Parameters and Conditions
The expected ranges of values as well as the measurement conditions are taken from Linear Technology
RH1014M Quad Precision Operational Amplifier Datasheet Revision G. All electrical tests for this
device are performed on one of Aeroflex RAD's LTS2020 Test Systems. The LTS2020 Test System is a
programmable parametric tester that provides parameter measurements for a variety of digital, analog
and mixed signal products including voltage regulators, voltage comparators, D to A and A to D
converters. The LTS2020 Test System achieves accuracy and sensitivity through the use of software
self-calibration and an internal relay matrix with separate family boards and custom personality adapter
boards. The tester uses this relay matrix to connect the required test circuits, select the appropriate
voltage / current sources and establish the needed measurement loops for all the tests performed. The
measured parameters and test conditions are shown in Table C.1.
A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The
precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020
for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table
C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between
tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90
KTL statistics were applied to the measured standard deviation to generate the final measurement range.
This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020
mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the
measurement resolution is limited by the internal DACs, which results in a measured standard deviation
of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC.
Note that the testing and statistics used in this document are based on an “analysis of variables”
technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p.
91 for a discussion of statistical treatments). Not all measured parameters are well suited to this
approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify
these parameters using an “attributes” approach.
An ISO 9001:2008 and DSCC Certified Company
183
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table C.1. Measured parameters and test conditions for the RH1014MW Quad Precision Operational Amplifier.
Parameter
Symbol
Test Conditions
Positive Supply Current 15V (A)
+IS_15V
VS= +/-15V, VCM= 0V
Negative Supply Current 15V (A)
-IS_15V
VS= +/-15V, VCM= 0V
Offset Voltage 15V (V)
VOS_15V
VS= +/-15V, VCM= 0V
Offset Current 15V (A)
IOS_15V
VS= +/-15V, VCM= 0V
Positive Bias Current 15V (A)
+IB_15V
VS= +/-15V, VCM= 0V
Negative Bias Current 15V (A)
-IB_15V
VS= +/-15V, VCM= 0V
Common Mode Rejection Ratio (dB)
CMRR
VS= +/-15V, VCM= 13V, -15V
Power Supply Rejection Ratio (dB)
PSRR
Open Loop Gain (V/mV)
AVOL
Positive Output Voltage 15V (V)
+VOUT_15V
VS= +/-10V to +/-18V, VCM= 0V
VS= +/-15V, VCM= 0V, VO= +/-10V,
RL= 10K
VS= +/-15V, VCM= 0V, RL= 10K
Negative Output Voltage 15V (V)
-VOUT_15V
VS= +/-15V, VCM= 0V, RL= 10K
Positive Slew Rate (V/us)
+SlewRate
VS= +/-15V
Negative Slew Rate (V/us)
-SlewRate
VS= +/-15V
Positive Supply Current 5V (A)
+IS_5V
VS= +5V, VCM= 0V, VOUT= 1.4V
Negative Supply Current 5V (A)
-IS_5V
VS= +5V, VCM= 0V, VOUT= 1.4V
Offset Voltage 5V (V)
VOS_5V
VS= +5V, VCM= 0V, VOUT= 1.4V
Offset Current 5V (A)
IOS_5V
VS= +5V, VCM= 0V, VOUT= 1.4V
Positive Bias Current 5V (A)
+IB_5V
VS= +5V, VCM= 0V, VOUT= 1.4V
Negative Bias Current 5V (A)
-IB_5V
Positive Output Voltage 5V OPEN (V)
+VOUT_5V OPEN
Positive Output Voltage 5V 600 (V)
+VOUT_5V 600
Output Voltage Low 5V OPEN (V)
-VOUT_5V OPEN
Output Voltage Low 5V 600 (V)
-VOUT_5V 600
Output Voltage Low 5V 1mA (V)
-VOUT_5V 1mA
VS= +5V, VCM= 0V, VOUT= 1.4V
VS= +5V, VCM= 0V, VOUT= 1.4V,
RL= OPEN
VS= +5V, VCM= 0V, VOUT= 1.4V,
RL= 600Ω
VS= +5V, VCM= 0V, VOUT= 1.4V,
RL= OPEN
VS= +5V, VCM= 0V, VOUT= 1.4V,
RL= 600Ω
VS= +5V, VCM= 0V, VOUT= 1.4V,
ISINK= 1mA
An ISO 9001:2008 and DSCC Certified Company
184
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH1014MW
Quad Precision Operational Amplifier.
Pre-Irradiation Specification
Parameter
MIN
MAX
Positive Supply Current 15V (A)
Measurement Precision/Resolution
2.20E-03
±4.59E-06
Negative Supply Current 15V (A)
-2.20E-03
±5.46E-06
Offset Voltage 15V (V)
-3.00E-04
3.00E-04
±1.77E-06
Offset Current 15V (A)
-1.00E-08
1.00E-08
±2.84E-11
Positive Bias Current 15V (A)
-3.00E-08
3.00E-08
±5.76E-11
Negative Bias Current 15V (A)
-3.00E-08
3.00E-08
±6.03E-11
Common Mode Rejection Ratio (dB)
9.70E+01
±2.06E+00
Power Supply Rejection Ratio (dB)
1.00E+02
±2.31E+01
Open Loop Gain (V/mV)
1.20E+03
±2.63E+02
Positive Output Voltage 15V (V)
1.25E+01
±2.19E-03
Negative Output Voltage 15V (V)
Positive Slew Rate (V/us)
-1.25E+01
2.00E-01
±1.96E-03
±1.11E-02
Negative Slew Rate (V/us)
-2.00E-01
±2.01E-02
Positive Supply Current 5V (A)
2.00E-03
±1.48E-05
Negative Supply Current 5V (A)
-2.00E-03
±1.08E-05
Offset Voltage 5V (V)
-4.50E-04
4.50E-04
±1.74E-06
Offset Current 5V (A)
-1.00E-08
1.00E-08
±4.13E-11
Positive Bias Current 5V (A)
-5.00E-08
5.00E-08
±7.16E-11
Negative Bias Current 5V (A)
-5.00E-08
5.00E-08
±5.13E-11
Positive Output Voltage 5V OPEN (V)
4.00E+00
±1.70E-03
Positive Output Voltage 5V 600 (V)
3.40E+00
±1.96E-03
Output Voltage Low 5V OPEN (V)
2.50E-02
±4.79E-04
Output Voltage Low 5V 600 (V)
1.00E-02
±4.75E-04
Output Voltage Low 5V 1mA (V)
3.50E-01
±1.63E-03
An ISO 9001:2008 and DSCC Certified Company
185
ELDRS Report
12-900 130307 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix D: List of Figures Used in the Results Section (Section 5)
5.1.
5.2.
5.3.
5.4.
5.5.
5.6.
5.7.
5.8.
5.9.
5.10.
5.11.
5.12.
5.13.
5.14.
5.15.
5.16.
5.17.
5.18.
5.19.
5.20.
5.21.
5.22.
5.23.
5.24.
5.25.
5.26.
5.27.
5.28.
5.29.
5.30.
5.31.
5.32.
5.33.
5.34.
5.35.
5.36.
5.37.
5.38.
5.39.
5.40.
Positive Supply Current 15V (A) @ VS= +/-15V, VCM= 0V
Negative Supply Current 15V (A) @ VS= +/-15V, VCM= 0V
Offset Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V
Offset Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V
Offset Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V
Offset Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V
Offset Current 15V 1 (A) @ VS= +/-15V, VCM= 0V
Offset Current 15V 2 (A) @ VS= +/-15V, VCM= 0V
Offset Current 15V 3 (A) @ VS= +/-15V, VCM= 0V
Offset Current 15V 4 (A) @ VS= +/-15V, VCM= 0V
Positive Bias Current 15V 1 (A) @ VS= +/-15V, VCM= 0V
Positive Bias Current 15V 2 (A) @ VS= +/-15V, VCM= 0V
Positive Bias Current 15V 3 (A) @ VS= +/-15V, VCM= 0V
Positive Bias Current 15V 4 (A) @ VS= +/-15V, VCM= 0V
Negative Bias Current 15V 1 (A) @ VS= +/-15V, VCM= 0V
Negative Bias Current 15V 2 (A) @ VS= +/-15V, VCM= 0V
Negative Bias Current 15V 3 (A) @ VS= +/-15V, VCM= 0V
Negative Bias Current 15V 4 (A) @ VS= +/-15V, VCM= 0V
Common Mode Rejection Ratio 1 (dB) @ VS= +/-15V, VCM= 13V, -15V
Common Mode Rejection Ratio 2 (dB) @ VS= +/-15V, VCM= 13V, -15V
Common Mode Rejection Ratio 3 (dB) @ VS= +/-15V, VCM= 13V, -15V
Common Mode Rejection Ratio 4 (dB) @ VS= +/-15V, VCM= 13V, -15V
Power Supply Rejection Ratio 1 (dB) @ VS= +/-10V to +/-18V, VCM= 0V
Power Supply Rejection Ratio 2 (dB) @ VS= +/-10V to +/-18V, VCM= 0V
Power Supply Rejection Ratio 3 (dB) @ VS= +/-10V to +/-18V, VCM= 0V
Power Supply Rejection Ratio 4 (dB) @ VS= +/-10V to +/-18V, VCM= 0V
Open Loop Gain 1 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
Open Loop Gain 2 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
Open Loop Gain 3 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
Open Loop Gain 4 (V/mV) @ VS= +/-15V, VCM= 0V, VO= +/-10V, RL= 10K
Positive Output Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
Positive Output Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
Positive Output Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
Positive Output Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
Negative Output Voltage 15V 1 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
Negative Output Voltage 15V 2 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
Negative Output Voltage 15V 3 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
Negative Output Voltage 15V 4 (V) @ VS= +/-15V, VCM= 0V, RL= 10K
Positive Slew Rate 1 (V/us) @ VS= +/-15V
Positive Slew Rate 2 (V/us) @ VS= +/-15V
An ISO 9001:2008 and DSCC Certified Company
186
ELDRS Report
12-900 130307 R1.0
5.41.
5.42.
5.43.
5.44.
5.45.
5.46.
5.47.
5.48.
5.49.
5.50.
5.51.
5.52.
5.53.
5.54.
5.55.
5.56.
5.57.
5.58.
5.59.
5.60.
5.61.
5.62.
5.63.
5.64.
5.65.
5.66.
5.67.
5.68.
5.69.
5.70.
5.71.
5.72.
5.73.
5.74.
5.75.
5.76.
5.77.
5.78.
5.79.
5.80.
5.81.
5.82.
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Positive Slew Rate 3 (V/us) @ VS= +/-15V
Positive Slew Rate 4 (V/us) @ VS= +/-15V
Negative Slew Rate 1 (V/us) @ VS= +/-15V
Negative Slew Rate 2 (V/us) @ VS= +/-15V
Negative Slew Rate 3 (V/us) @ VS= +/-15V
Negative Slew Rate 4 (V/us) @ VS= +/-15V
Positive Supply Current 5V (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Negative Supply Current 5V (A) @ VS= +5V , VCM= 0V, VOUT= 1.4V
Offset Voltage 5V 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Offset Voltage 5V 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Offset Voltage 5V 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Offset Voltage 5V 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Offset Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Offset Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Offset Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Offset Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Positive Bias Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Positive Bias Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Positive Bias Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Positive Bias Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Negative Bias Current 5V 1 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Negative Bias Current 5V 2 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Negative Bias Current 5V 3 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Negative Bias Current 5V 4 (A) @ VS= +5V, VCM= 0V, VOUT= 1.4V
Positive Output Voltage 5V OPEN 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Positive Output Voltage 5V OPEN 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Positive Output Voltage 5V OPEN 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Positive Output Voltage 5V OPEN 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Positive Output Voltage 5V 600 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Positive Output Voltage 5V 600 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Positive Output Voltage 5V 600 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Positive Output Voltage 5V 600 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Output Voltage Low 5V OPEN 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Output Voltage Low 5V OPEN 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Output Voltage Low 5V OPEN 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Output Voltage Low 5V OPEN 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= OPEN
Output Voltage Low 5V 600 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Output Voltage Low 5V 600 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Output Voltage Low 5V 600 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Output Voltage Low 5V 600 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, RL= 600Ω
Output Voltage Low 5V 1mA 1 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
Output Voltage Low 5V 1mA 2 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
An ISO 9001:2008 and DSCC Certified Company
187
ELDRS Report
12-900 130307 R1.0
5.83.
5.84.
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Output Voltage Low 5V 1mA 3 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
Output Voltage Low 5V 1mA 4 (V) @ VS= +5V, VCM= 0V, VOUT= 1.4V, ISINK= 1mA
An ISO 9001:2008 and DSCC Certified Company
188