RLAT_200K_Report_RH1013MH_W10905043.1_W18.pdf

TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Products contained in this shipment may be subject to ITAR
regulations.
Warning:
The export of these commodity(ies), technology, or software are subject either to the
U.S. Commerce Department Export Administration Regulations (E.A.R.), or to the U.S.
State Department International Traffic In Arms Regulations (I.T.A.R.). Diversion, the
shipment to unauthorized locations or entities, or the disclosure of related technical data
or software to unauthorized foreign nationals is contrary to U.S. law and is prohibited. If
export is authorized to a specific country or end-users, compliance with the U.S. export
laws is required prior to transfer, transshipment on a non-continuous voyage, or disposal
in any other country, or to any other end-user of these commodities, either in their
original form or after being incorporated into other end-items.
An ISO 9001:2008 and DLA Certified Company
1
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Radiation Lot Acceptance Testing (RLAT) of the RH1013MH Dual Precision
Operational Amplifier for Linear Technology
Customer: Linear Technology, PO# 68651L
RAD Job Number: 14-0247
Part Type Tested: RH1013MH Dual Precision Operational Amplifier, Linear Technology RH1013M
Datasheet Revision E
Traceability Information: Fab Lot Number: W10905043.1, Lot Number: 709855, Wafer Number: 18,
Date Code: 1314A. See photograph of unit under test in Appendix A.
Quantity of Units: 12 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 2
units for control. Serial numbers 27, 28, 29, 30 and 31 were biased during irradiation, serial numbers 32,
33, 34, 35 and 36 were unbiased during irradiation and serial numbers 37 and 38 were used as control.
See Appendix B for the radiation bias connection table.
Radiation and Electrical Test Increments: 50rad(Si)/s ionizing radiation with electrical test
increments: pre-irradiation, 20krad(Si), 50krad(Si), 100krad(Si) and 200krad(Si).
Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD
Overtest and Post-Irradiation Anneal: No overtest. 24-hour room temperature anneal followed by a
168-hour 100°C anneal. Both anneals were performed in the same electrical bias condition as the
irradiations. Electrical measurements were made following each anneal increment.
Radiation Test Standard: MIL-STD-750 TM1019 and/or MIL-STD-883 TM1019 Condition A and
Linear Technology RH1013M Datasheet Revision E.
Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS03, Calibration Date:
4/30/2014, Calibration Due: 4/30/2015. LTS2101 Family Board, Entity ID FB10. LTS0600 Test Fixture,
Entity ID TF03. RH1013 DUT Board. Test Program: RH1013LT.SRC
Facility and Radiation Source: Aeroflex RAD's, Colorado Springs, CO. Gamma rays provided by
JLSA 81-24 Co60 source. Dosimetry performed by Air Ionization Chamber (AIC) traceable to NIST.
Aeroflex RAD's dosimetry has been audited by DLA and Aeroflex RAD has been awarded Laboratory
Suitability for MIL-STD-750 and MIL-STD-883 TM 1019.
Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and
MIL-STD-750.
Test Result:
 PASSED the total ionizing dose test to the 200krad(Si) dose level
 PASSED following 24-hour room temperature anneal
 PASSED following 168-hour 100°C anneal
An ISO 9001:2008 and DLA Certified Company
2
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
1.0. Overview and Background
It is well known that total dose ionizing radiation can cause parametric degradation and ultimately
functional failure in electronic devices. The damage occurs via electron-hole pair production, transport
and trapping in the dielectric and interface regions. In discrete devices the bulk of the damage is
frequently manifested as a reduction in the gain and/or breakdown voltage of the device. The damage
will usually anneal with time following the end of the radiation exposure. Due to this annealing, and to
ensure a worst-case test condition MIL-STD-883H TM1019 calls out a dose rate of 50 to 300rad(Si)/s as
Condition A and further specifies that the time from the end of an incremental radiation exposure and
electrical testing shall be 1-hour or less and the total time from the end of one incremental irradiation to
the beginning of the next incremental radiation step should be 2-hours or less. The work described in
this report was performed to meet MIL-STD-883H TM1019 Condition A.
2.0. Radiation Test Apparatus
The total ionizing dose testing described in this final report was performed using the facilities at
Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose
(TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are
held in the base of the irradiator heavily shielded by lead. During the radiation exposures the rod is
raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this
irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 300rad(Si)/s,
determined by the distance from the source. For high-dose rate experiments the bias boards are placed in
a radial fashion equidistant from the raised Co-60 rods with the distance adjusted to provide the required
dose rate. The irradiator calibration is maintained by Aeroflex RAD Longmire Laboratories using air
ionization chamber (AIC) equipment calibrated with traceability to the National Institute of Standards
and Technology (NIST). Figure 2.1 shows a photograph of the JLSA 81-24 Co-60 irradiator at
Aeroflex RAD's Longmire Laboratory facility.
Aeroflex RAD is currently certified by the Defense Supply Center Columbus (DLA) for Laboratory
Suitability under MIL STD 750 and MIL-STD-883H. Additional details regarding Aeroflex RAD
dosimetry for TM1019 Condition A testing are available in Aeroflex RAD's report to DLA entitled:
"Dose Rate Mapping of the J.L. Shepherd and Associates Model 81 Irradiator Installed by Radiation
Assured Devices".
An ISO 9001:2008 and DLA Certified Company
3
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Figure 2.1. Aeroflex RAD's high dose rate Co-60 irradiator. The dose rate is obtained by positioning the deviceunder-test at a fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately
300rad(Si)/s close to the rods down to 1rad(Si)/s at a distance of approximately 2-feet.
An ISO 9001:2008 and DLA Certified Company
4
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
3.0. Radiation Test Conditions
The RH1013MH Dual Precision Operational Amplifier described in this final report were irradiated
using a split 15V supply and with all pins tied to ground, that is biased and unbiased. See the TID Bias
Table in Appendix B for the full bias circuits. In our opinion, this bias circuit satisfies the requirements
of MIL-STD-883H TM1019 Section 3.9.3 Bias and Loading Conditions which states "The bias applied
to the test devices shall be selected to produce the greatest radiation induced damage or the worst-case
damage for the intended application, if known. While maximum voltage is often worst case some
bipolar linear device parameters (e.g. input bias current or maximum output load current) exhibit more
degradation with 0 V bias."
The devices were irradiated to a maximum total ionizing dose level of 200krad(Si) with incremental
readings at 20krad(Si), 50krad(Si) and 100krad(Si). Electrical testing occurred within one hour
following the end of each irradiation segment. For intermediate irradiations, the parts were tested and
returned to total dose exposure within two hours from the end of the previous radiation increment.
The TID bias board was positioned in the Co-60 cell to provide the required minimum of 50rad(Si)/s
and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test
specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm
Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and
for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1)
initially, (2) when the source is changed, or (3) when the orientation or configuration of the source,
container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g.,
a TLD) in the device-irradiation container at the approximate test-device position. If it can be
demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors
due to dose enhancement, the Pb/Al container may be omitted."
The final dose rate within the high dose rate lead-aluminum enclosure was determined using calibration
calculations based on air ionization chamber (AIC) dosimetry performed just prior to beginning the total
dose irradiations. The final dose rate for this work was 55.3rad(Si)/s with a precision of ±5%.
An ISO 9001:2008 and DLA Certified Company
5
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
4.0. Tested Parameters
During the total ionizing dose characterization testing the following electrical parameters were measured
pre- and post-irradiation:
1. Positive Supply Current 15V (A) @ VS=+/-15V, VCM=0V
2. Negative Supply Current 15V (A) @ VS=+/-15V, VCM=0V
3. Input Offset Voltage1 15V (V) @ VS=+/-15V, VCM=0V
4. Input Offset Voltage2 15V (V) @ VS=+/-15V, VCM=0V
5. Input Offset Current1 15V (A) @ VS=+/-15V, VCM=0V
6. Input Offset Current2 15V (A) @ VS=+/-15V, VCM=0V
7. Positive Input Bias Current1 15V (A) @ VS=+/-15V, VCM=0V
8. Positive Input Bias Current2 15V (A) @ VS=+/-15V, VCM=0V
9. Negative Input Bias Current1 15V (A) @ VS=+/-15V, VCM=0V
10. Negative Input Bias Current2 15V (A) @ VS=+/-15V, VCM=0V
11. Common Mode Rejection Ratio1 15V (dB) @ VCM=+13V, -15V
12. Common Mode Rejection Ratio2 15V (dB) @ VCM=+13V, -15V
13. Power Supply Rejection Ratio1 15V (dB) @ VS=+/-10V to +/-18V
14. Power Supply Rejection Ratio2 15V (dB) @ VS=+/-10V to +/-18V
15. Large-Signal Voltage Gain1 15V (V/mV) @ RL=10K, VO=+/-10V
16. Large-Signal Voltage Gain2 15V (V/mV) @ RL=10K, VO=+/-10V
17. Positive Output Voltage Swing1 15V (V) @ VS=+/-15V, VCM=0V, RL=10k
18. Positive Output Voltage Swing2 15V (V) @ VS=+/-15V, VCM=0V, RL=10k
19. Negative Output Voltage Swing1 15V (V) @ VS=+/-15V, VCM=0V, RL=10k
20. Negative Output Voltage Swing2 15V (V) @ VS=+/-15V, VCM=0V, RL=10k
21. Positive Slew Rate1 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V
22. Positive Slew Rate2 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V
23. Negative Slew Rate1 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V
24. Negative Slew Rate2 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V
25. Positive Supply Current 5V (A) @ +VS=5V, -VS=0V, VCM=0V, VOUT=4V
26. Negative Supply Current 5V (A) @ +VS=5V, -VS=0V, VCM=0V, VOUT=4V
27. Input Offset Voltage1 5V (V) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
28. Input Offset Voltage2 5V (V) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
29. Input Offset Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
30. Input Offset Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
31. Positive Input Bias Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
32. Positive Input Bias Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
33. Negative Input Bias Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
34. Negative Input Bias Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
35. Positive Output Voltage High 5V Open 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
36. Positive Output Voltage High 5V Open 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
37. Positive Output Voltage High 5V 600 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
An ISO 9001:2008 and DLA Certified Company
6
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
38. Positive Output Voltage High 5V 600 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
39. Negative Output Voltage Low 5V Open 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
40. Negative Output Voltage Low 5V Open 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
41. Negative Output Voltage Low 5V 600 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
42. Negative Output Voltage Low 5V 600 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
43. Negative Output Voltage Low 5V 1mA 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, ISINK=1mA
44. Negative Output Voltage Low 5V 1mA 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, ISINK=1mA
Appendix C details the measured parameters, test conditions, pre-irradiation specification and
measurement resolution for each of the measurements.
The parametric data was obtained as "read and record" and all the raw data plus an attributes summary
are contained in this report as well as in a separate Excel file. The attributes data contains the average,
standard deviation and the average with the KTL values applied. The KTL value used in this work is
2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The
90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535
sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the
following criteria must be met for a device to pass the total ionizing dose test: following the radiation
exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units
irradiated without electrical bias and the KTL statistics are included in this report for reference only. If
any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet
specification limits, then the lot could be logged as a failure.
An ISO 9001:2008 and DLA Certified Company
7
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
5.0. Total Ionizing Dose Test Results
Based on this criterion the RH1013MH Dual Precision Operational Amplifier (from the lot traceability
information provided on the first page of this test report) the units-under-test:
 PASSED the total ionizing dose test to the 200krad(Si) dose level
 PASSED following 24-hour room temperature anneal
 PASSED following 168-hour 100°C anneal
Figures 5.1 through 5.44 show plots of all the measured parameters versus total ionizing dose while
Tables 5.1 - 5.44 show the corresponding raw data for each of these parameters. In the data plots the
solid diamonds are the average of the measured data points for the sample irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the units irradiated with all
pins tied to ground. The black lines (solid or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the sample irradiated in the biased condition while the shaded lines
(solid or dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the
sample irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation
minimum and/or maximum specification value as defined in the datasheet and/or test plan.
The control units, as expected, show no significant changes to any of the parameters. Therefore we can
conclude that the electrical testing remained in control throughout the duration of the tests and the
observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section
to facilitate the location of a particular parameter.
An ISO 9001:2008 and DLA Certified Company
8
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
1.20E-03
Positive Supply Current 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-03
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.1. Plot of Positive Supply Current 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
9
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.1. Raw data for Positive Supply Current 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Positive Supply Current 15V (A)
@ VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
200
5.68E-04
6.02E-04
5.87E-04
6.05E-04
6.05E-04
5.73E-04
5.72E-04
5.68E-04
5.69E-04
5.77E-04
8.11E-04
7.99E-04
24-hr
Anneal
250
5.84E-04
5.94E-04
5.83E-04
5.97E-04
5.98E-04
5.70E-04
5.70E-04
5.65E-04
5.68E-04
5.76E-04
8.12E-04
8.03E-04
168-hr
Anneal
300
5.99E-04
6.14E-04
5.93E-04
6.06E-04
6.00E-04
5.96E-04
5.91E-04
5.95E-04
5.99E-04
6.00E-04
8.15E-04
8.01E-04
7.16E-04
4.66E-06
7.29E-04
7.03E-04
5.93E-04
1.60E-05
6.37E-04
5.49E-04
5.91E-04
7.19E-06
6.11E-04
5.71E-04
6.02E-04
7.96E-06
6.24E-04
5.81E-04
7.11E-04
7.35E-06
7.31E-04
6.91E-04
1.10E-03
PASS
5.72E-04
3.56E-06
5.82E-04
5.62E-04
1.10E-03
PASS
5.70E-04
4.02E-06
5.81E-04
5.59E-04
1.10E-03
PASS
5.96E-04
3.56E-06
6.06E-04
5.86E-04
1.10E-03
PASS
0
8.01E-04
8.02E-04
8.02E-04
8.02E-04
8.08E-04
7.99E-04
7.95E-04
8.08E-04
8.09E-04
8.05E-04
8.15E-04
8.01E-04
Total
20
8.00E-04
8.09E-04
7.98E-04
7.99E-04
7.99E-04
8.08E-04
8.09E-04
8.18E-04
8.17E-04
8.11E-04
8.14E-04
8.03E-04
Dose (krad(Si))
50
100
7.84E-04 7.18E-04
7.91E-04 7.17E-04
7.82E-04 7.08E-04
7.87E-04 7.19E-04
7.88E-04 7.19E-04
7.81E-04 7.07E-04
7.79E-04 7.05E-04
7.93E-04 7.13E-04
7.85E-04 7.07E-04
7.84E-04 7.23E-04
8.12E-04 8.13E-04
8.01E-04 8.00E-04
8.03E-04
2.83E-06
8.11E-04
7.95E-04
8.01E-04
4.53E-06
8.13E-04
7.89E-04
7.86E-04
3.51E-06
7.96E-04
7.77E-04
8.03E-04
6.02E-06
8.20E-04
7.87E-04
1.10E-03
PASS
8.13E-04
4.62E-06
8.25E-04
8.00E-04
1.10E-03
PASS
7.84E-04
5.37E-06
7.99E-04
7.70E-04
1.10E-03
PASS
An ISO 9001:2008 and DLA Certified Company
10
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Negative Supply Current 15V (A)
@ VS=+/-15V, VCM=0V
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
-1.20E-03
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.2. Plot of Negative Supply Current 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
11
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.2. Raw data for Negative Supply Current 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Negative Supply Current 15V (A)
@ VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
-5.69E-04
-6.02E-04
-5.88E-04
-6.06E-04
-6.04E-04
-5.76E-04
-5.74E-04
-5.71E-04
-5.72E-04
-5.79E-04
-8.12E-04
-8.01E-04
24-hr
Anneal
250
-5.84E-04
-5.93E-04
-5.85E-04
-5.99E-04
-5.99E-04
-5.70E-04
-5.72E-04
-5.66E-04
-5.68E-04
-5.75E-04
-8.14E-04
-8.04E-04
168-hr
Anneal
300
-6.01E-04
-6.14E-04
-5.93E-04
-6.08E-04
-6.00E-04
-5.96E-04
-5.92E-04
-5.97E-04
-6.00E-04
-6.01E-04
-8.17E-04
-8.02E-04
-7.17E-04
4.77E-06
-7.04E-04
-7.30E-04
-5.94E-04
1.56E-05
-5.51E-04
-6.36E-04
-5.92E-04
7.28E-06
-5.72E-04
-6.12E-04
-6.03E-04
8.04E-06
-5.81E-04
-6.25E-04
-7.12E-04
5.90E-06
-6.96E-04
-7.29E-04
-1.10E-03
PASS
-5.74E-04
3.21E-06
-5.66E-04
-5.83E-04
-1.10E-03
PASS
-5.70E-04
3.49E-06
-5.61E-04
-5.80E-04
-1.10E-03
PASS
-5.97E-04
3.56E-06
-5.87E-04
-6.07E-04
-1.10E-03
PASS
0
-8.00E-04
-8.05E-04
-8.00E-04
-8.02E-04
-8.06E-04
-8.01E-04
-7.96E-04
-8.11E-04
-8.06E-04
-8.01E-04
-8.16E-04
-8.02E-04
Total
20
-8.02E-04
-8.09E-04
-7.98E-04
-8.01E-04
-8.01E-04
-8.10E-04
-8.10E-04
-8.19E-04
-8.19E-04
-8.13E-04
-8.14E-04
-8.05E-04
Dose (krad(Si))
50
100
-7.86E-04 -7.19E-04
-7.92E-04 -7.19E-04
-7.82E-04 -7.09E-04
-7.89E-04 -7.19E-04
-7.89E-04 -7.21E-04
-7.83E-04 -7.10E-04
-7.79E-04 -7.08E-04
-7.95E-04 -7.14E-04
-7.85E-04 -7.08E-04
-7.86E-04 -7.22E-04
-8.13E-04 -8.12E-04
-8.03E-04 -8.01E-04
-8.03E-04
2.79E-06
-7.95E-04
-8.10E-04
-8.02E-04
4.09E-06
-7.91E-04
-8.13E-04
-7.88E-04
3.78E-06
-7.77E-04
-7.98E-04
-8.03E-04
5.70E-06
-7.87E-04
-8.19E-04
-1.10E-03
PASS
-8.14E-04
4.55E-06
-8.02E-04
-8.27E-04
-1.10E-03
PASS
-7.86E-04
5.90E-06
-7.69E-04
-8.02E-04
-1.10E-03
PASS
An ISO 9001:2008 and DLA Certified Company
12
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
4.00E-04
Input Offset Voltage1 15V (V)
@ VS=+/-15V, VCM=0V
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.3. Plot of Input Offset Voltage1 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
13
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.3. Raw data for Input Offset Voltage1 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage1 15V (V)
@ VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
200
3.33E-04
1.15E-04
2.32E-04
2.03E-04
2.50E-04
2.79E-04
2.75E-04
2.20E-04
3.03E-04
3.16E-04
8.39E-05
6.57E-05
24-hr
Anneal
250
2.65E-04
1.21E-04
2.18E-04
1.80E-04
2.21E-04
2.27E-04
2.21E-04
1.86E-04
2.46E-04
2.63E-04
8.85E-05
7.58E-05
168-hr
Anneal
300
1.39E-04
5.80E-05
1.18E-04
1.09E-04
1.34E-04
1.35E-04
1.15E-04
1.65E-04
1.22E-04
1.38E-04
9.01E-05
6.50E-05
5.38E-05
3.16E-05
1.41E-04
-3.29E-05
2.27E-04
7.88E-05
4.43E-04
1.07E-05
2.01E-04
5.41E-05
3.49E-04
5.24E-05
1.12E-04
3.24E-05
2.01E-04
2.29E-05
6.99E-05
1.25E-05
1.04E-04
3.56E-05
-7.50E-04
PASS
7.50E-04
PASS
2.78E-04
3.68E-05
3.79E-04
1.77E-04
-9.00E-04
PASS
9.00E-04
PASS
2.29E-04
2.89E-05
3.08E-04
1.49E-04
-9.00E-04
PASS
9.00E-04
PASS
1.35E-04
1.91E-05
1.88E-04
8.29E-05
-9.00E-04
PASS
9.00E-04
PASS
0
3.97E-06
-1.99E-05
3.54E-05
-7.73E-06
1.36E-05
3.78E-05
-3.02E-06
6.17E-05
-1.64E-05
1.67E-05
8.46E-05
6.74E-05
Total
20
-1.41E-05
-3.84E-05
1.28E-05
-1.97E-05
-4.90E-06
1.54E-05
-2.25E-05
4.27E-05
-3.49E-05
-2.48E-06
8.32E-05
6.83E-05
Dose (krad(Si))
50
100
4.39E-06 5.90E-05
-3.29E-05 2.82E-06
3.03E-05 8.47E-05
3.50E-07 4.90E-05
3.64E-05 7.37E-05
2.87E-05 7.65E-05
-1.56E-05 5.08E-05
4.03E-05 7.18E-05
-1.54E-05 6.62E-05
1.63E-05 8.41E-05
8.50E-05 8.29E-05
7.03E-05 6.46E-05
5.07E-06
2.11E-05
6.29E-05
-5.28E-05
-1.29E-05
1.89E-05
3.89E-05
-6.46E-05
7.71E-06
2.76E-05
8.34E-05
-6.79E-05
1.93E-05
3.13E-05
1.05E-04
-6.64E-05
-3.00E-04
PASS
3.00E-04
PASS
-3.72E-07
3.08E-05
8.40E-05
-8.48E-05
-4.50E-04
PASS
4.50E-04
PASS
1.09E-05
2.55E-05
8.08E-05
-5.91E-05
-6.00E-04
PASS
6.00E-04
PASS
An ISO 9001:2008 and DLA Certified Company
14
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
4.00E-04
Input Offset Voltage2 15V (V)
@ VS=+/-15V, VCM=0V
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.4. Plot of Input Offset Voltage2 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
15
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.4. Raw data for Input Offset Voltage2 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage2 15V (V)
@ VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
200
4.12E-04
1.27E-04
1.91E-04
2.58E-04
1.74E-04
3.79E-04
3.35E-04
1.78E-04
3.15E-04
4.13E-04
8.52E-05
5.19E-05
24-hr
Anneal
250
3.19E-04
1.11E-04
1.38E-04
2.14E-04
8.28E-05
3.24E-04
2.63E-04
1.36E-04
2.42E-04
3.41E-04
7.96E-05
4.69E-05
168-hr
Anneal
300
1.67E-04
4.62E-05
5.54E-05
1.30E-04
3.92E-05
1.71E-04
1.09E-04
8.20E-05
8.30E-05
1.85E-04
8.33E-05
5.36E-05
6.05E-05
5.90E-05
2.22E-04
-1.01E-04
2.32E-04
1.11E-04
5.37E-04
-7.16E-05
1.73E-04
9.50E-05
4.33E-04
-8.75E-05
8.75E-05
5.74E-05
2.45E-04
-6.99E-05
9.58E-05
6.09E-05
2.63E-04
-7.13E-05
-7.50E-04
PASS
7.50E-04
PASS
3.24E-04
9.04E-05
5.72E-04
7.63E-05
-9.00E-04
PASS
9.00E-04
PASS
2.61E-04
8.11E-05
4.84E-04
3.87E-05
-9.00E-04
PASS
9.00E-04
PASS
1.26E-04
4.91E-05
2.61E-04
-8.42E-06
-9.00E-04
PASS
9.00E-04
PASS
0
5.90E-05
-1.21E-05
-4.15E-05
4.17E-05
-6.51E-05
9.14E-05
-4.47E-06
-9.10E-07
-4.36E-05
6.73E-05
8.84E-05
4.94E-05
Total
20
5.52E-05
-3.05E-05
-4.31E-05
3.55E-05
-7.68E-05
6.86E-05
-3.38E-05
-3.06E-05
-5.20E-05
5.42E-05
8.70E-05
5.01E-05
Dose (krad(Si))
50
100
7.09E-05 1.34E-04
-1.45E-05 1.62E-05
-1.59E-05 3.29E-05
6.18E-05 1.13E-04
-3.72E-05 5.96E-06
9.40E-05 1.58E-04
-3.39E-06 8.25E-05
-2.74E-05 1.74E-05
-1.45E-05 6.46E-05
7.77E-05 1.57E-04
8.48E-05 8.14E-05
5.34E-05 4.90E-05
-3.61E-06
5.31E-05
1.42E-04
-1.49E-04
-1.19E-05
5.54E-05
1.40E-04
-1.64E-04
1.30E-05
4.96E-05
1.49E-04
-1.23E-04
2.19E-05
5.57E-05
1.75E-04
-1.31E-04
-3.00E-04
PASS
3.00E-04
PASS
1.28E-06
5.57E-05
1.54E-04
-1.52E-04
-4.50E-04
PASS
4.50E-04
PASS
2.53E-05
5.62E-05
1.79E-04
-1.29E-04
-6.00E-04
PASS
6.00E-04
PASS
An ISO 9001:2008 and DLA Certified Company
16
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
5.00E-09
Input Offset Current1 15V (A)
@ VS=+/-15V, VCM=0V
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
-2.50E-08
-3.00E-08
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.5. Plot of Input Offset Current1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
17
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.5. Raw data for Input Offset Current1 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current1 15V (A)
@ VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
200
9.22E-10
-1.59E-10
-5.16E-10
-6.81E-10
5.48E-10
-2.00E-11
-2.02E-10
-1.26E-09
1.38E-10
9.40E-11
4.60E-11
-9.00E-12
24-hr
Anneal
250
3.39E-10
-1.84E-10
-2.57E-10
-4.02E-10
4.99E-10
-8.00E-12
-4.88E-10
-1.06E-09
-6.30E-11
4.70E-11
3.40E-11
0.00E+00
168-hr
Anneal
300
4.97E-10
-1.01E-10
-1.04E-10
-3.90E-10
4.90E-11
-3.19E-10
-1.64E-10
-4.39E-10
-1.83E-10
-3.40E-11
1.70E-11
-8.00E-12
-1.01E-10
1.80E-10
3.92E-10
-5.93E-10
2.28E-11
6.90E-10
1.91E-09
-1.87E-09
-1.00E-12
3.95E-10
1.08E-09
-1.09E-09
-9.80E-12
3.25E-10
8.81E-10
-9.00E-10
-1.48E-11
3.45E-10
9.31E-10
-9.61E-10
-2.00E-08
PASS
2.00E-08
PASS
-2.50E-10
5.80E-10
1.34E-09
-1.84E-09
-2.50E-08
PASS
2.50E-08
PASS
-3.15E-10
4.68E-10
9.68E-10
-1.60E-09
-2.50E-08
PASS
2.50E-08
PASS
-2.28E-10
1.55E-10
1.98E-10
-6.54E-10
-2.50E-08
PASS
2.50E-08
PASS
0
3.40E-11
3.00E-12
5.90E-11
-3.60E-11
8.90E-11
3.00E-12
-8.00E-11
-5.60E-11
3.00E-11
-2.90E-11
3.40E-11
-2.10E-11
Total
20
-2.50E-11
1.40E-11
2.70E-11
-8.10E-11
8.60E-11
9.00E-12
-3.70E-11
-9.60E-11
4.90E-11
-2.50E-11
3.30E-11
-8.00E-12
Dose (krad(Si))
50
100
-8.60E-11 -3.90E-11
-1.83E-10 -2.21E-10
5.30E-11 -1.26E-10
-2.37E-10 -2.90E-10
9.30E-11 1.72E-10
5.70E-11 5.90E-11
4.90E-11 -3.00E-12
-2.23E-10 -6.01E-10
2.40E-10 2.10E-10
3.50E-11 2.61E-10
4.30E-11 5.90E-11
-7.00E-12 -6.00E-12
2.98E-11
4.85E-11
1.63E-10
-1.03E-10
4.20E-12
6.21E-11
1.74E-10
-1.66E-10
-7.20E-11
1.44E-10
3.22E-10
-4.66E-10
-2.64E-11
4.42E-11
9.47E-11
-1.47E-10
-1.00E-08
PASS
1.00E-08
PASS
-2.00E-11
5.41E-11
1.28E-10
-1.68E-10
-1.00E-08
PASS
1.00E-08
PASS
3.16E-11
1.65E-10
4.85E-10
-4.21E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DLA Certified Company
18
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
0.00E+00
Input Offset Current2 15V (A)
@ VS=+/-15V, VCM=0V
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
-2.50E-08
-3.00E-08
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.6. Plot of Input Offset Current2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
19
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.6. Raw data for Input Offset Current2 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current2 15V (A)
@ VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
200
9.93E-10
-4.02E-10
-7.17E-10
-4.78E-10
7.90E-11
-7.18E-10
-6.69E-10
-1.79E-09
3.00E-11
-5.24E-10
-2.50E-11
-2.20E-11
24-hr
Anneal
250
3.31E-10
-5.14E-10
-2.47E-10
-4.30E-10
2.24E-10
-9.96E-10
-7.80E-10
-1.97E-09
-4.48E-10
-5.59E-10
-3.90E-11
-1.50E-11
168-hr
Anneal
300
3.30E-10
-3.36E-10
-1.78E-10
-3.60E-11
-2.58E-10
-5.42E-10
-2.06E-10
-4.19E-10
-1.21E-10
-5.35E-10
-2.80E-11
-7.00E-12
-1.91E-10
1.83E-10
3.10E-10
-6.93E-10
-1.05E-10
6.78E-10
1.76E-09
-1.97E-09
-1.27E-10
3.84E-10
9.25E-10
-1.18E-09
-9.56E-11
2.63E-10
6.24E-10
-8.15E-10
-4.01E-10
2.42E-10
2.63E-10
-1.07E-09
-2.00E-08
PASS
2.00E-08
PASS
-7.35E-10
6.62E-10
1.08E-09
-2.55E-09
-2.50E-08
PASS
2.50E-08
PASS
-9.51E-10
6.08E-10
7.16E-10
-2.62E-09
-2.50E-08
PASS
2.50E-08
PASS
-3.65E-10
1.92E-10
1.63E-10
-8.92E-10
-2.50E-08
PASS
2.50E-08
PASS
0
-8.00E-12
-6.00E-11
-9.80E-11
-4.60E-11
-1.14E-10
-6.00E-11
-6.40E-11
-2.60E-11
-1.20E-11
-1.40E-11
-3.70E-11
-8.00E-12
Total
20
-1.12E-10
-1.04E-10
-2.23E-10
-7.30E-11
-1.05E-10
-1.34E-10
-1.15E-10
-5.20E-11
-1.78E-10
-1.50E-11
-3.80E-11
-1.50E-11
Dose (krad(Si))
50
100
-7.20E-11 -1.70E-10
-6.00E-12 -2.48E-10
-1.99E-10 -4.40E-10
-2.70E-10 -1.68E-10
2.00E-12 6.90E-11
-4.20E-11 -4.70E-10
-1.71E-10 -3.62E-10
-2.55E-10 -7.70E-10
-7.30E-11 -1.19E-10
-6.50E-11 -2.86E-10
-4.00E-11 -4.00E-11
0.00E+00 -5.00E-12
-6.52E-11
4.22E-11
5.05E-11
-1.81E-10
-1.23E-10
5.77E-11
3.47E-11
-2.82E-10
-1.09E-10
1.21E-10
2.22E-10
-4.40E-10
-3.52E-11
2.51E-11
3.36E-11
-1.04E-10
-1.00E-08
PASS
1.00E-08
PASS
-9.88E-11
6.52E-11
7.99E-11
-2.77E-10
-1.00E-08
PASS
1.00E-08
PASS
-1.21E-10
8.96E-11
1.25E-10
-3.67E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DLA Certified Company
20
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.00E-07
Positive Input Bias Current1 15V (A)
@ VS=+/-15V, VCM=0V
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.7. Plot of Positive Input Bias Current1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
21
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.7. Raw data for Positive Input Bias Current1 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Input Bias Current1 15V (A)
@ VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
Dose (krad(Si))
50
100
2.06E-08 3.49E-08
2.05E-08 3.34E-08
2.10E-08 3.40E-08
2.14E-08 3.45E-08
2.00E-08 3.18E-08
1.99E-08 3.16E-08
2.11E-08 3.36E-08
2.09E-08 3.37E-08
2.11E-08 3.33E-08
1.97E-08 3.16E-08
8.48E-09 8.46E-09
8.60E-09 8.59E-09
200
5.94E-08
5.68E-08
5.88E-08
5.90E-08
5.44E-08
5.49E-08
5.76E-08
5.88E-08
5.62E-08
5.41E-08
8.48E-09
8.59E-09
24-hr
Anneal
250
5.88E-08
5.69E-08
5.91E-08
5.93E-08
5.52E-08
5.04E-08
5.34E-08
5.37E-08
5.21E-08
4.99E-08
8.48E-09
8.61E-09
168-hr
Anneal
300
4.33E-08
4.23E-08
4.52E-08
4.61E-08
4.25E-08
3.67E-08
3.96E-08
3.84E-08
3.86E-08
3.69E-08
8.52E-09
8.59E-09
0
9.09E-09
8.91E-09
9.59E-09
1.01E-08
9.17E-09
9.04E-09
9.87E-09
9.22E-09
9.89E-09
9.25E-09
8.50E-09
8.60E-09
Total
20
1.31E-08
1.31E-08
1.37E-08
1.42E-08
1.31E-08
1.29E-08
1.39E-08
1.34E-08
1.39E-08
1.31E-08
8.47E-09
8.61E-09
9.36E-09
4.58E-10
1.06E-08
8.11E-09
1.34E-08
4.77E-10
1.47E-08
1.21E-08
2.07E-08
5.13E-10
2.21E-08
1.93E-08
3.37E-08
1.22E-09
3.70E-08
3.04E-08
5.77E-08
2.07E-09
6.33E-08
5.20E-08
5.78E-08
1.79E-09
6.27E-08
5.29E-08
4.39E-08
1.70E-09
4.85E-08
3.92E-08
9.45E-09
3.97E-10
1.05E-08
8.37E-09
-3.00E-08
PASS
3.00E-08
PASS
1.34E-08
4.70E-10
1.47E-08
1.21E-08
-7.50E-08
PASS
7.50E-08
PASS
2.05E-08
7.01E-10
2.24E-08
1.86E-08
-1.00E-07
PASS
1.00E-07
PASS
3.27E-08
1.09E-09
3.57E-08
2.98E-08
-1.75E-07
PASS
1.75E-07
PASS
5.63E-08
1.91E-09
6.15E-08
5.11E-08
-2.50E-07
PASS
2.50E-07
PASS
5.19E-08
1.71E-09
5.66E-08
4.72E-08
-2.50E-07
PASS
2.50E-07
PASS
3.80E-08
1.20E-09
4.13E-08
3.47E-08
-2.50E-07
PASS
2.50E-07
PASS
An ISO 9001:2008 and DLA Certified Company
22
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.00E-07
Positive Input Bias Current2 15V (A)
@ VS=+/-15V, VCM=0V
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.8. Plot of Positive Input Bias Current2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
23
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.8. Raw data for Positive Input Bias Current2 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Input Bias Current2 15V (A)
@ VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
Dose (krad(Si))
50
100
2.23E-08 3.76E-08
1.99E-08 3.28E-08
2.17E-08 3.54E-08
2.09E-08 3.39E-08
2.06E-08 3.27E-08
2.16E-08 3.45E-08
2.18E-08 3.46E-08
2.16E-08 3.49E-08
2.20E-08 3.47E-08
2.17E-08 3.50E-08
9.42E-09 9.42E-09
9.44E-09 9.41E-09
200
6.36E-08
5.60E-08
6.09E-08
5.77E-08
5.63E-08
5.95E-08
5.93E-08
6.04E-08
5.86E-08
5.96E-08
9.37E-09
9.42E-09
24-hr
Anneal
250
6.30E-08
5.62E-08
6.12E-08
5.81E-08
5.67E-08
5.51E-08
5.53E-08
5.58E-08
5.47E-08
5.54E-08
9.39E-09
9.41E-09
168-hr
Anneal
300
4.68E-08
4.15E-08
4.70E-08
4.50E-08
4.40E-08
4.00E-08
4.08E-08
3.95E-08
4.04E-08
4.13E-08
9.44E-09
9.43E-09
0
9.91E-09
8.73E-09
9.81E-09
9.91E-09
9.58E-09
9.88E-09
9.99E-09
9.54E-09
1.03E-08
1.03E-08
9.41E-09
9.42E-09
Total
20
1.42E-08
1.29E-08
1.42E-08
1.39E-08
1.36E-08
1.41E-08
1.43E-08
1.38E-08
1.46E-08
1.43E-08
9.43E-09
9.43E-09
9.59E-09
4.98E-10
1.10E-08
8.22E-09
1.38E-08
5.46E-10
1.53E-08
1.23E-08
2.11E-08
9.35E-10
2.37E-08
1.85E-08
3.45E-08
2.04E-09
4.01E-08
2.89E-08
5.89E-08
3.29E-09
6.79E-08
4.99E-08
5.90E-08
2.93E-09
6.71E-08
5.10E-08
4.49E-08
2.22E-09
5.09E-08
3.88E-08
9.99E-09
3.09E-10
1.08E-08
9.15E-09
-3.00E-08
PASS
3.00E-08
PASS
1.42E-08
2.76E-10
1.50E-08
1.35E-08
-7.50E-08
PASS
7.50E-08
PASS
2.17E-08
1.76E-10
2.22E-08
2.13E-08
-1.00E-07
PASS
1.00E-07
PASS
3.47E-08
2.03E-10
3.53E-08
3.42E-08
-1.75E-07
PASS
1.75E-07
PASS
5.95E-08
6.58E-10
6.13E-08
5.77E-08
-2.50E-07
PASS
2.50E-07
PASS
5.53E-08
4.35E-10
5.64E-08
5.41E-08
-2.50E-07
PASS
2.50E-07
PASS
4.04E-08
6.69E-10
4.22E-08
3.86E-08
-2.50E-07
PASS
2.50E-07
PASS
An ISO 9001:2008 and DLA Certified Company
24
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Negative Input Bias Current1 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.9. Plot of Negative Input Bias Current1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
25
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.9. Raw data for Negative Input Bias Current1 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Input Bias Current1 15V (A)
@ VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
Dose (krad(Si))
50
100
2.06E-08 3.49E-08
2.04E-08 3.33E-08
2.11E-08 3.40E-08
2.12E-08 3.43E-08
2.01E-08 3.20E-08
1.99E-08 3.18E-08
2.13E-08 3.36E-08
2.08E-08 3.33E-08
2.13E-08 3.36E-08
1.98E-08 3.18E-08
8.50E-09 8.53E-09
8.61E-09 8.62E-09
200
6.05E-08
5.68E-08
5.84E-08
5.84E-08
5.51E-08
5.50E-08
5.75E-08
5.76E-08
5.64E-08
5.44E-08
8.50E-09
8.59E-09
24-hr
Anneal
250
5.93E-08
5.68E-08
5.89E-08
5.90E-08
5.58E-08
5.06E-08
5.32E-08
5.29E-08
5.22E-08
5.02E-08
8.50E-09
8.60E-09
168-hr
Anneal
300
4.39E-08
4.23E-08
4.52E-08
4.58E-08
4.26E-08
3.65E-08
3.95E-08
3.80E-08
3.85E-08
3.70E-08
8.53E-09
8.58E-09
0
9.13E-09
8.87E-09
9.62E-09
1.00E-08
9.28E-09
9.01E-09
9.76E-09
9.16E-09
9.93E-09
9.26E-09
8.51E-09
8.60E-09
Total
20
1.30E-08
1.31E-08
1.37E-08
1.41E-08
1.32E-08
1.29E-08
1.39E-08
1.33E-08
1.40E-08
1.31E-08
8.54E-09
8.64E-09
9.38E-09
4.47E-10
1.06E-08
8.16E-09
1.34E-08
4.62E-10
1.47E-08
1.22E-08
2.07E-08
4.60E-10
2.19E-08
1.94E-08
3.37E-08
1.10E-09
3.67E-08
3.07E-08
5.78E-08
2.01E-09
6.33E-08
5.23E-08
5.80E-08
1.57E-09
6.23E-08
5.36E-08
4.40E-08
1.55E-09
4.82E-08
3.97E-08
9.42E-09
3.99E-10
1.05E-08
8.33E-09
-3.00E-08
PASS
3.00E-08
PASS
1.34E-08
4.86E-10
1.47E-08
1.21E-08
-7.50E-08
PASS
7.50E-08
PASS
2.06E-08
7.17E-10
2.26E-08
1.86E-08
-1.00E-07
PASS
1.00E-07
PASS
3.28E-08
9.34E-10
3.54E-08
3.03E-08
-1.75E-07
PASS
1.75E-07
PASS
5.62E-08
1.46E-09
6.02E-08
5.22E-08
-2.50E-07
PASS
2.50E-07
PASS
5.18E-08
1.36E-09
5.55E-08
4.81E-08
-2.50E-07
PASS
2.50E-07
PASS
3.79E-08
1.20E-09
4.12E-08
3.46E-08
-2.50E-07
PASS
2.50E-07
PASS
An ISO 9001:2008 and DLA Certified Company
26
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Negative Input Bias Current2 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.10. Plot of Negative Input Bias Current2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
27
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.10. Raw data for Negative Input Bias Current2 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Input Bias Current2 15V (A)
@ VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
Dose (krad(Si))
50
100
2.23E-08 3.75E-08
2.00E-08 3.26E-08
2.15E-08 3.51E-08
2.07E-08 3.38E-08
2.07E-08 3.29E-08
2.16E-08 3.41E-08
2.17E-08 3.43E-08
2.14E-08 3.41E-08
2.20E-08 3.48E-08
2.17E-08 3.48E-08
9.39E-09 9.34E-09
9.40E-09 9.41E-09
200
6.47E-08
5.57E-08
6.03E-08
5.73E-08
5.65E-08
5.89E-08
5.88E-08
5.88E-08
5.88E-08
5.92E-08
9.38E-09
9.40E-09
24-hr
Anneal
250
6.34E-08
5.58E-08
6.11E-08
5.78E-08
5.70E-08
5.42E-08
5.47E-08
5.41E-08
5.45E-08
5.50E-08
9.35E-09
9.43E-09
168-hr
Anneal
300
4.72E-08
4.13E-08
4.69E-08
4.51E-08
4.39E-08
3.95E-08
4.06E-08
3.91E-08
4.03E-08
4.08E-08
9.40E-09
9.39E-09
0
9.88E-09
8.64E-09
9.71E-09
9.87E-09
9.44E-09
9.85E-09
9.97E-09
9.49E-09
1.02E-08
1.02E-08
9.36E-09
9.40E-09
Total
20
1.41E-08
1.28E-08
1.40E-08
1.39E-08
1.35E-08
1.40E-08
1.42E-08
1.38E-08
1.45E-08
1.44E-08
9.37E-09
9.42E-09
9.51E-09
5.17E-10
1.09E-08
8.09E-09
1.37E-08
5.15E-10
1.51E-08
1.23E-08
2.10E-08
8.91E-10
2.35E-08
1.86E-08
3.44E-08
1.98E-09
3.98E-08
2.89E-08
5.89E-08
3.69E-09
6.90E-08
4.88E-08
5.90E-08
3.15E-09
6.77E-08
5.04E-08
4.48E-08
2.40E-09
5.14E-08
3.83E-08
9.96E-09
3.12E-10
1.08E-08
9.10E-09
-3.00E-08
PASS
3.00E-08
PASS
1.41E-08
2.74E-10
1.49E-08
1.34E-08
-7.50E-08
PASS
7.50E-08
PASS
2.17E-08
2.16E-10
2.23E-08
2.11E-08
-1.00E-07
PASS
1.00E-07
PASS
3.44E-08
3.21E-10
3.53E-08
3.35E-08
-1.75E-07
PASS
1.75E-07
PASS
5.89E-08
1.91E-10
5.94E-08
5.84E-08
-2.50E-07
PASS
2.50E-07
PASS
5.45E-08
3.59E-10
5.55E-08
5.35E-08
-2.50E-07
PASS
2.50E-07
PASS
4.01E-08
7.11E-10
4.20E-08
3.81E-08
-2.50E-07
PASS
2.50E-07
PASS
An ISO 9001:2008 and DLA Certified Company
28
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio1 15V (dB)
@ VCM=+13V, -15V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.11. Plot of Common Mode Rejection Ratio1 15V (dB) @ VCM=+13V, -15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
29
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.11. Raw data for Common Mode Rejection Ratio1 15V (dB) @ VCM=+13V, -15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio1 15V (dB)
@ VCM=+13V, -15V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
1.07E+02
1.10E+02
1.06E+02
1.09E+02
1.05E+02
1.07E+02
1.04E+02
1.10E+02
1.05E+02
1.05E+02
1.21E+02
1.14E+02
24-hr
Anneal
250
1.09E+02
1.13E+02
1.07E+02
1.11E+02
1.06E+02
1.08E+02
1.05E+02
1.12E+02
1.06E+02
1.07E+02
1.21E+02
1.14E+02
168-hr
Anneal
300
1.14E+02
1.19E+02
1.10E+02
1.17E+02
1.09E+02
1.15E+02
1.11E+02
1.42E+02
1.12E+02
1.13E+02
1.22E+02
1.14E+02
1.09E+02
2.52E+00
1.16E+02
1.02E+02
1.07E+02
2.14E+00
1.13E+02
1.01E+02
1.09E+02
2.81E+00
1.17E+02
1.02E+02
1.14E+02
4.41E+00
1.26E+02
1.02E+02
1.09E+02
3.42E+00
1.18E+02
9.96E+01
9.00E+01
PASS
1.06E+02
2.21E+00
1.12E+02
1.00E+02
8.60E+01
PASS
1.08E+02
2.67E+00
1.15E+02
1.00E+02
8.60E+01
PASS
1.19E+02
1.34E+01
1.55E+02
8.19E+01
8.60E+01
PASS
0
1.19E+02
1.38E+02
1.15E+02
1.28E+02
1.13E+02
1.25E+02
1.16E+02
1.20E+02
1.21E+02
1.21E+02
1.21E+02
1.14E+02
Total
20
1.13E+02
1.19E+02
1.11E+02
1.17E+02
1.09E+02
1.15E+02
1.11E+02
1.47E+02
1.14E+02
1.14E+02
1.21E+02
1.14E+02
Dose (krad(Si))
50
100
1.10E+02 1.09E+02
1.15E+02 1.12E+02
1.09E+02 1.07E+02
1.13E+02 1.11E+02
1.08E+02 1.06E+02
1.11E+02 1.09E+02
1.08E+02 1.06E+02
1.20E+02 1.15E+02
1.10E+02 1.08E+02
1.10E+02 1.07E+02
1.21E+02 1.21E+02
1.14E+02 1.14E+02
1.23E+02
1.04E+01
1.51E+02
9.41E+01
1.14E+02
4.24E+00
1.26E+02
1.02E+02
1.11E+02
3.07E+00
1.19E+02
1.03E+02
1.21E+02
3.27E+00
1.30E+02
1.12E+02
9.70E+01
PASS
1.20E+02
1.50E+01
1.61E+02
7.89E+01
9.70E+01
PASS
1.12E+02
4.81E+00
1.25E+02
9.87E+01
9.40E+01
PASS
An ISO 9001:2008 and DLA Certified Company
30
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio2 15V (dB)
@ VCM=+13V, -15V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.12. Plot of Common Mode Rejection Ratio2 15V (dB) @ VCM=+13V, -15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
31
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.12. Raw data for Common Mode Rejection Ratio2 15V (dB) @ VCM=+13V, -15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio2 15V (dB)
@ VCM=+13V, -15V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
1.07E+02
1.08E+02
1.04E+02
1.06E+02
1.04E+02
1.06E+02
1.05E+02
1.06E+02
1.04E+02
1.05E+02
1.26E+02
1.17E+02
24-hr
Anneal
250
1.09E+02
1.09E+02
1.05E+02
1.08E+02
1.07E+02
1.07E+02
1.06E+02
1.08E+02
1.05E+02
1.05E+02
1.26E+02
1.17E+02
168-hr
Anneal
300
1.12E+02
1.12E+02
1.07E+02
1.10E+02
1.08E+02
1.11E+02
1.11E+02
1.15E+02
1.09E+02
1.11E+02
1.26E+02
1.17E+02
1.07E+02
1.90E+00
1.12E+02
1.02E+02
1.06E+02
1.46E+00
1.10E+02
1.02E+02
1.08E+02
1.63E+00
1.12E+02
1.03E+02
1.10E+02
2.34E+00
1.16E+02
1.04E+02
1.07E+02
1.32E+00
1.11E+02
1.04E+02
9.00E+01
PASS
1.05E+02
8.99E-01
1.08E+02
1.03E+02
8.60E+01
PASS
1.06E+02
1.07E+00
1.09E+02
1.03E+02
8.60E+01
PASS
1.11E+02
2.07E+00
1.17E+02
1.06E+02
8.60E+01
PASS
0
1.19E+02
1.17E+02
1.10E+02
1.14E+02
1.12E+02
1.18E+02
1.17E+02
1.25E+02
1.14E+02
1.16E+02
1.27E+02
1.17E+02
Total
20
1.14E+02
1.13E+02
1.08E+02
1.10E+02
1.09E+02
1.13E+02
1.12E+02
1.15E+02
1.10E+02
1.11E+02
1.26E+02
1.17E+02
Dose (krad(Si))
50
100
1.11E+02 1.09E+02
1.11E+02 1.09E+02
1.06E+02 1.05E+02
1.09E+02 1.08E+02
1.07E+02 1.06E+02
1.10E+02 1.08E+02
1.09E+02 1.07E+02
1.12E+02 1.09E+02
1.08E+02 1.06E+02
1.09E+02 1.07E+02
1.26E+02 1.27E+02
1.17E+02 1.17E+02
1.14E+02
3.59E+00
1.24E+02
1.05E+02
1.11E+02
2.76E+00
1.18E+02
1.03E+02
1.09E+02
2.07E+00
1.14E+02
1.03E+02
1.18E+02
4.11E+00
1.29E+02
1.07E+02
9.70E+01
PASS
1.12E+02
2.05E+00
1.18E+02
1.07E+02
9.70E+01
PASS
1.09E+02
1.62E+00
1.14E+02
1.05E+02
9.40E+01
PASS
An ISO 9001:2008 and DLA Certified Company
32
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio1 15V (dB)
@ VS=+/-10V to +/-18V
1.60E+02
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.13. Plot of Power Supply Rejection Ratio1 15V (dB) @ VS=+/-10V to +/-18V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
33
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.13. Raw data for Power Supply Rejection Ratio1 15V (dB) @ VS=+/-10V to +/-18V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio1 15V (dB)
@ VS=+/-10V to +/-18V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
1.22E+02
1.27E+02
1.21E+02
1.19E+02
1.16E+02
1.18E+02
1.15E+02
1.27E+02
1.15E+02
1.16E+02
1.22E+02
1.40E+02
24-hr
Anneal
250
1.34E+02
1.33E+02
1.24E+02
1.22E+02
1.17E+02
1.23E+02
1.18E+02
1.46E+02
1.17E+02
1.18E+02
1.22E+02
1.41E+02
168-hr
Anneal
300
1.22E+02
1.28E+02
1.37E+02
1.36E+02
1.25E+02
1.25E+02
1.33E+02
1.19E+02
1.40E+02
1.29E+02
1.22E+02
1.41E+02
1.34E+02
1.38E+01
1.72E+02
9.59E+01
1.21E+02
4.09E+00
1.32E+02
1.10E+02
1.26E+02
7.44E+00
1.46E+02
1.05E+02
1.30E+02
6.74E+00
1.48E+02
1.11E+02
1.28E+02
8.01E+00
1.50E+02
1.06E+02
8.60E+01
PASS
1.18E+02
5.34E+00
1.33E+02
1.03E+02
8.00E+01
PASS
1.24E+02
1.21E+01
1.57E+02
9.10E+01
8.00E+01
PASS
1.29E+02
8.17E+00
1.51E+02
1.07E+02
8.00E+01
PASS
0
1.22E+02
1.25E+02
1.31E+02
1.36E+02
1.30E+02
1.25E+02
1.43E+02
1.19E+02
1.32E+02
1.29E+02
1.22E+02
1.40E+02
Total
20
1.25E+02
1.28E+02
1.39E+02
1.57E+02
1.25E+02
1.28E+02
1.39E+02
1.21E+02
1.44E+02
1.35E+02
1.22E+02
1.39E+02
Dose (krad(Si))
50
100
1.29E+02 1.42E+02
1.34E+02 1.54E+02
1.42E+02 1.28E+02
1.33E+02 1.26E+02
1.22E+02 1.20E+02
1.39E+02 1.42E+02
1.29E+02 1.22E+02
1.23E+02 1.28E+02
1.32E+02 1.23E+02
1.39E+02 1.25E+02
1.22E+02 1.22E+02
1.41E+02 1.42E+02
1.29E+02
5.52E+00
1.44E+02
1.14E+02
1.35E+02
1.36E+01
1.72E+02
9.73E+01
1.32E+02
7.26E+00
1.52E+02
1.12E+02
1.29E+02
8.79E+00
1.54E+02
1.05E+02
1.00E+02
PASS
1.33E+02
8.94E+00
1.58E+02
1.09E+02
9.80E+01
PASS
1.32E+02
6.90E+00
1.51E+02
1.13E+02
9.40E+01
PASS
An ISO 9001:2008 and DLA Certified Company
34
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio2 15V (dB)
@ VS=+/-10V to +/-18V
1.60E+02
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.14. Plot of Power Supply Rejection Ratio2 15V (dB) @ VS=+/-10V to +/-18V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
35
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.14. Raw data for Power Supply Rejection Ratio2 15V (dB) @ VS=+/-10V to +/-18V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio2 15V (dB)
@ VS=+/-10V to +/-18V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
1.18E+02
1.46E+02
1.19E+02
1.20E+02
1.16E+02
1.13E+02
1.13E+02
1.17E+02
1.11E+02
1.12E+02
1.26E+02
1.39E+02
24-hr
Anneal
250
1.25E+02
1.30E+02
1.22E+02
1.24E+02
1.18E+02
1.15E+02
1.16E+02
1.19E+02
1.13E+02
1.14E+02
1.26E+02
1.37E+02
168-hr
Anneal
300
1.34E+02
1.21E+02
1.43E+02
1.68E+02
1.25E+02
1.27E+02
1.40E+02
1.58E+02
1.23E+02
1.31E+02
1.26E+02
1.38E+02
1.27E+02
4.96E+00
1.40E+02
1.13E+02
1.24E+02
1.25E+01
1.58E+02
8.94E+01
1.24E+02
4.27E+00
1.35E+02
1.12E+02
1.38E+02
1.86E+01
1.89E+02
8.72E+01
1.20E+02
2.93E+00
1.28E+02
1.12E+02
8.60E+01
PASS
1.13E+02
2.01E+00
1.19E+02
1.08E+02
8.00E+01
PASS
1.15E+02
2.17E+00
1.21E+02
1.09E+02
8.00E+01
PASS
1.36E+02
1.40E+01
1.74E+02
9.73E+01
8.00E+01
PASS
0
1.27E+02
1.21E+02
1.46E+02
1.35E+02
1.35E+02
1.35E+02
1.54E+02
1.32E+02
1.27E+02
1.40E+02
1.26E+02
1.38E+02
Total
20
1.31E+02
1.23E+02
1.34E+02
1.59E+02
1.28E+02
1.29E+02
1.35E+02
1.52E+02
1.23E+02
1.29E+02
1.26E+02
1.39E+02
Dose (krad(Si))
50
100
1.47E+02 1.34E+02
1.25E+02 1.28E+02
1.28E+02 1.23E+02
1.34E+02 1.27E+02
1.24E+02 1.21E+02
1.24E+02 1.20E+02
1.27E+02 1.20E+02
1.37E+02 1.25E+02
1.20E+02 1.17E+02
1.26E+02 1.20E+02
1.26E+02 1.25E+02
1.39E+02 1.38E+02
1.33E+02
9.50E+00
1.59E+02
1.07E+02
1.35E+02
1.42E+01
1.74E+02
9.62E+01
1.32E+02
9.78E+00
1.58E+02
1.05E+02
1.38E+02
1.02E+01
1.65E+02
1.10E+02
1.00E+02
PASS
1.34E+02
1.08E+01
1.63E+02
1.04E+02
9.80E+01
PASS
1.27E+02
6.18E+00
1.44E+02
1.10E+02
9.40E+01
PASS
An ISO 9001:2008 and DLA Certified Company
36
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Large-Signal Voltage Gain1 15V (V/mV)
@ RL=10K, VO=+/-10V
4.00E+04
3.00E+04
2.00E+04
1.00E+04
0.00E+00
-1.00E+04
-2.00E+04
-3.00E+04
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.15. Plot of Large-Signal Voltage Gain1 15V (V/mV) @ RL=10K, VO=+/-10V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
37
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.15. Raw data for Large-Signal Voltage Gain1 15V (V/mV) @ RL=10K, VO=+/-10V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Large-Signal Voltage Gain1 15V (V/mV)
@ RL=10K, VO=+/-10V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Dose (krad(Si))
50
100
4.47E+03 1.94E+03
9.11E+03 3.04E+03
3.88E+03 1.82E+03
6.66E+03 2.27E+03
4.17E+03 1.85E+03
4.44E+03 2.44E+03
3.73E+03 1.88E+03
8.40E+03 2.85E+03
3.52E+03 1.96E+03
4.18E+03 1.88E+03
2.43E+05 4.79E+05
5.21E+04 1.07E+05
200
5.03E+02
9.91E+02
6.26E+02
7.79E+02
6.90E+02
6.61E+02
5.66E+02
7.43E+02
5.40E+02
5.66E+02
2.43E+05
5.43E+04
24-hr
Anneal
250
6.00E+02
9.33E+02
6.61E+02
7.61E+02
6.40E+02
7.08E+02
6.16E+02
8.17E+02
5.38E+02
6.04E+02
2.48E+05
5.68E+04
168-hr
Anneal
300
8.32E+02
1.30E+03
8.15E+02
9.07E+02
7.61E+02
8.78E+02
6.95E+02
1.09E+03
6.54E+02
7.15E+02
8.62E+04
1.70E+05
0
2.43E+04
5.11E+04
1.93E+04
4.97E+04
1.80E+04
2.99E+04
2.61E+04
3.28E+04
2.08E+04
2.00E+04
1.37E+06
7.56E+04
Total
20
1.21E+04
4.73E+04
1.04E+04
2.02E+04
8.78E+03
1.19E+04
1.02E+04
2.87E+04
9.90E+03
9.28E+03
7.93E+05
6.21E+04
3.25E+04
1.65E+04
7.79E+04
-1.29E+04
1.98E+04
1.60E+04
6.36E+04
-2.41E+04
5.66E+03
2.22E+03
1.17E+04
-4.21E+02
2.18E+03
5.14E+02
3.59E+03
7.74E+02
7.18E+02
1.83E+02
1.22E+03
2.16E+02
7.19E+02
1.34E+02
1.09E+03
3.53E+02
9.23E+02
2.17E+02
1.52E+03
3.29E+02
2.59E+04
5.59E+03
4.12E+04
1.06E+04
1.20E+03
PASS
1.40E+04
8.30E+03
3.68E+04
-8.75E+03
2.00E+02
PASS
4.85E+03
2.02E+03
1.04E+04
-6.76E+02
1.00E+02
PASS
2.20E+03
4.30E+02
3.38E+03
1.02E+03
5.00E+01
PASS
6.15E+02
8.50E+01
8.48E+02
3.82E+02
2.50E+01
PASS
6.57E+02
1.08E+02
9.53E+02
3.60E+02
2.50E+01
PASS
8.07E+02
1.80E+02
1.30E+03
3.12E+02
2.50E+01
PASS
An ISO 9001:2008 and DLA Certified Company
38
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Large-Signal Voltage Gain2 15V (V/mV)
@ RL=10K, VO=+/-10V
4.00E+04
3.00E+04
2.00E+04
1.00E+04
0.00E+00
-1.00E+04
-2.00E+04
-3.00E+04
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.16. Plot of Large-Signal Voltage Gain2 15V (V/mV) @ RL=10K, VO=+/-10V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
39
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.16. Raw data for Large-Signal Voltage Gain2 15V (V/mV) @ RL=10K, VO=+/-10V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Large-Signal Voltage Gain2 15V (V/mV)
@ RL=10K, VO=+/-10V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
4.32E+04
3.42E+04
1.79E+04
1.99E+04
1.39E+04
7.09E+04
2.27E+04
2.93E+04
2.57E+04
3.23E+04
4.50E+04
4.05E+04
Total Dose (krad(Si))
20
50
100
1.31E+04 5.62E+03 2.09E+03
2.26E+04 6.93E+03 2.75E+03
9.68E+03 4.32E+03 1.83E+03
9.80E+03 4.73E+03 2.06E+03
7.22E+03 4.70E+03 1.86E+03
2.15E+04 7.02E+03 2.16E+03
1.15E+04 5.07E+03 2.02E+03
4.48E+04 9.56E+03 3.19E+03
1.03E+04 4.29E+03 1.83E+03
8.25E+03 5.47E+03 1.98E+03
4.23E+04 7.50E+04 7.42E+04
3.71E+04 6.38E+04 7.48E+04
200
5.20E+02
9.05E+02
6.97E+02
7.73E+02
6.85E+02
7.56E+02
6.05E+02
8.64E+02
5.39E+02
6.23E+02
6.65E+04
4.78E+04
24-hr
Anneal
250
6.34E+02
9.06E+02
6.49E+02
7.69E+02
6.85E+02
7.64E+02
6.64E+02
9.36E+02
5.44E+02
6.30E+02
6.19E+04
6.62E+04
168-hr
Anneal
300
8.45E+02
1.32E+03
8.24E+02
9.74E+02
7.89E+02
9.53E+02
7.20E+02
1.22E+03
6.73E+02
7.54E+02
4.42E+04
7.27E+04
2.58E+04
1.24E+04
5.97E+04
-8.10E+03
1.25E+04
6.04E+03
2.90E+04
-4.07E+03
5.26E+03
1.05E+03
8.13E+03
2.38E+03
2.12E+03
3.71E+02
3.13E+03
1.10E+03
7.16E+02
1.40E+02
1.10E+03
3.31E+02
7.29E+02
1.12E+02
1.04E+03
4.21E+02
9.51E+02
2.19E+02
1.55E+03
3.51E+02
3.62E+04
1.98E+04
9.04E+04
-1.80E+04
1.20E+03
PASS
1.93E+04
1.52E+04
6.08E+04
-2.23E+04
2.00E+02
PASS
6.28E+03
2.09E+03
1.20E+04
5.64E+02
1.00E+02
PASS
2.24E+03
5.46E+02
3.73E+03
7.39E+02
5.00E+01
PASS
6.77E+02
1.31E+02
1.04E+03
3.19E+02
2.50E+01
PASS
7.08E+02
1.50E+02
1.12E+03
2.96E+02
2.50E+01
PASS
8.63E+02
2.24E+02
1.48E+03
2.48E+02
2.50E+01
PASS
An ISO 9001:2008 and DLA Certified Company
40
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage Swing1 15V (V)
@ VS=+/-15V, VCM=0V, RL=10k
1.42E+01
1.40E+01
1.38E+01
1.36E+01
1.34E+01
1.32E+01
1.30E+01
1.28E+01
1.26E+01
1.24E+01
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.17. Plot of Positive Output Voltage Swing1 15V (V) @ VS=+/-15V, VCM=0V, RL=10k versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
41
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.17. Raw data for Positive Output Voltage Swing1 15V (V) @ VS=+/-15V, VCM=0V, RL=10k versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage Swing1 15V (V)
@ VS=+/-15V, VCM=0V, RL=10k
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
24-hr
Anneal
250
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
168-hr
Anneal
300
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
5.17E-03
1.41E+01
1.41E+01
1.41E+01
5.22E-03
1.41E+01
1.41E+01
1.41E+01
5.10E-03
1.41E+01
1.41E+01
1.41E+01
5.66E-03
1.41E+01
1.41E+01
1.41E+01
5.55E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.76E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.31E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.76E-03
1.41E+01
1.41E+01
1.25E+01
PASS
0
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Total
20
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Dose (krad(Si))
50
100
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01
4.36E-03
1.41E+01
1.41E+01
1.41E+01
5.45E-03
1.41E+01
1.41E+01
1.41E+01
4.47E-03
1.41E+01
1.41E+01
1.41E+01
5.43E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.18E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.02E-03
1.41E+01
1.41E+01
1.25E+01
PASS
An ISO 9001:2008 and DLA Certified Company
42
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage Swing2 15V (V)
@ VS=+/-15V, VCM=0V, RL=10k
1.42E+01
1.40E+01
1.38E+01
1.36E+01
1.34E+01
1.32E+01
1.30E+01
1.28E+01
1.26E+01
1.24E+01
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.18. Plot of Positive Output Voltage Swing2 15V (V) @ VS=+/-15V, VCM=0V, RL=10k versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
43
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.18. Raw data for Positive Output Voltage Swing2 15V (V) @ VS=+/-15V, VCM=0V, RL=10k versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage Swing2 15V (V)
@ VS=+/-15V, VCM=0V, RL=10k
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
24-hr
Anneal
250
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
168-hr
Anneal
300
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
5.37E-03
1.41E+01
1.41E+01
1.41E+01
5.07E-03
1.41E+01
1.41E+01
1.41E+01
5.10E-03
1.41E+01
1.41E+01
1.41E+01
5.12E-03
1.41E+01
1.41E+01
1.41E+01
5.46E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.76E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
6.14E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.76E-03
1.41E+01
1.41E+01
1.25E+01
PASS
0
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Total
20
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
1.41E+01
Dose (krad(Si))
50
100
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01 1.41E+01
1.41E+01
3.96E-03
1.41E+01
1.41E+01
1.41E+01
5.73E-03
1.41E+01
1.41E+01
1.41E+01
5.02E-03
1.41E+01
1.41E+01
1.41E+01
5.54E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
4.85E-03
1.41E+01
1.41E+01
1.25E+01
PASS
1.41E+01
5.37E-03
1.41E+01
1.41E+01
1.25E+01
PASS
An ISO 9001:2008 and DLA Certified Company
44
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage Swing1 15V (V)
@ VS=+/-15V, VCM=0V, RL=10k
-1.20E+01
-1.25E+01
-1.30E+01
-1.35E+01
-1.40E+01
-1.45E+01
-1.50E+01
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.19. Plot of Negative Output Voltage Swing1 15V (V) @ VS=+/-15V, VCM=0V, RL=10k versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
45
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.19. Raw data for Negative Output Voltage Swing1 15V (V) @ VS=+/-15V, VCM=0V, RL=10k versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Output Voltage Swing1 15V (V)
@ VS=+/-15V, VCM=0V, RL=10k
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
Total Dose (krad(Si))
20
50
100
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
200
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
24-hr
Anneal
250
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
168-hr
Anneal
300
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01
1.14E-03 8.94E-04 1.48E-03 2.28E-03 2.49E-03 2.95E-03 2.95E-03
-1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01
2.24E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
-1.47E+01
2.55E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
-1.47E+01
2.19E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
-1.47E+01
2.35E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
An ISO 9001:2008 and DLA Certified Company
46
-1.47E+01
2.19E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
-1.47E+01
2.28E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
-1.47E+01
2.61E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage Swing2 15V (V)
@ VS=+/-15V, VCM=0V, RL=10k
-1.20E+01
-1.25E+01
-1.30E+01
-1.35E+01
-1.40E+01
-1.45E+01
-1.50E+01
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.20. Plot of Negative Output Voltage Swing2 15V (V) @ VS=+/-15V, VCM=0V, RL=10k versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
47
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.20. Raw data for Negative Output Voltage Swing2 15V (V) @ VS=+/-15V, VCM=0V, RL=10k versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Output Voltage Swing2 15V (V)
@ VS=+/-15V, VCM=0V, RL=10k
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
Total Dose (krad(Si))
20
50
100
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01
200
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
24-hr
Anneal
250
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
168-hr
Anneal
300
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01
1.10E-03 1.10E-03 1.48E-03 2.24E-03 2.49E-03 2.17E-03 2.61E-03
-1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01 -1.47E+01
-1.47E+01
1.73E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
-1.47E+01
2.68E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
-1.47E+01
2.19E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
-1.47E+01
2.19E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
An ISO 9001:2008 and DLA Certified Company
48
-1.47E+01
2.28E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
-1.47E+01
2.19E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
-1.47E+01
2.45E-03
-1.47E+01
-1.47E+01
-1.25E+01
PASS
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
4.50E-01
Positive Slew Rate1 15V (V/µs)
@ AV=1, VS=+/-15V, VCM=0V
4.00E-01
3.50E-01
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.21. Plot of Positive Slew Rate1 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
49
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.21. Raw data for Positive Slew Rate1 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Slew Rate1 15V (V/µs)
@ AV=1, VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
2.94E-01
3.18E-01
2.91E-01
3.08E-01
2.83E-01
2.87E-01
2.79E-01
2.90E-01
2.79E-01
2.89E-01
3.92E-01
4.04E-01
24-hr
Anneal
250
3.01E-01
3.05E-01
3.11E-01
3.00E-01
2.89E-01
2.81E-01
2.78E-01
3.03E-01
2.21E-01
2.86E-01
3.92E-01
3.94E-01
168-hr
Anneal
300
3.11E-01
3.31E-01
3.12E-01
3.12E-01
3.12E-01
3.13E-01
3.09E-01
3.25E-01
3.04E-01
3.05E-01
3.91E-01
4.14E-01
3.42E-01
7.02E-03
3.61E-01
3.22E-01
2.99E-01
1.40E-02
3.37E-01
2.60E-01
3.01E-01
8.07E-03
3.23E-01
2.79E-01
3.16E-01
8.62E-03
3.39E-01
2.92E-01
3.38E-01
1.22E-02
3.71E-01
3.04E-01
7.00E-02
PASS
2.85E-01
5.40E-03
3.00E-01
2.70E-01
1.00E-02
PASS
2.74E-01
3.11E-02
3.59E-01
1.89E-01
1.00E-02
PASS
3.11E-01
8.50E-03
3.34E-01
2.88E-01
1.00E-02
PASS
0
3.96E-01
4.29E-01
4.00E-01
3.81E-01
3.96E-01
4.06E-01
3.98E-01
4.01E-01
3.96E-01
3.74E-01
4.16E-01
4.02E-01
Total
20
3.90E-01
4.05E-01
3.69E-01
4.17E-01
3.76E-01
3.90E-01
3.64E-01
4.02E-01
3.84E-01
3.74E-01
3.96E-01
4.10E-01
Dose (krad(Si))
50
100
3.84E-01 3.36E-01
4.01E-01 3.46E-01
3.53E-01 3.43E-01
3.67E-01 3.33E-01
3.64E-01 3.50E-01
3.73E-01 3.56E-01
3.68E-01 3.36E-01
3.79E-01 3.40E-01
3.71E-01 3.22E-01
3.41E-01 3.35E-01
3.90E-01 4.01E-01
4.26E-01 4.03E-01
4.00E-01
1.76E-02
4.49E-01
3.52E-01
3.91E-01
1.99E-02
4.46E-01
3.37E-01
3.74E-01
1.88E-02
4.25E-01
3.22E-01
3.95E-01
1.23E-02
4.29E-01
3.61E-01
2.00E-01
PASS
3.83E-01
1.46E-02
4.23E-01
3.43E-01
1.20E-01
PASS
3.66E-01
1.48E-02
4.07E-01
3.26E-01
1.10E-01
PASS
An ISO 9001:2008 and DLA Certified Company
50
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
4.50E-01
Positive Slew Rate2 15V (V/µs)
@ AV=1, VS=+/-15V, VCM=0V
4.00E-01
3.50E-01
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.22. Plot of Positive Slew Rate2 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
51
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.22. Raw data for Positive Slew Rate2 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Slew Rate2 15V (V/µs)
@ AV=1, VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
3.09E-01
3.19E-01
2.99E-01
3.20E-01
3.02E-01
2.97E-01
3.01E-01
3.21E-01
2.89E-01
3.20E-01
4.13E-01
4.36E-01
24-hr
Anneal
250
3.27E-01
3.21E-01
3.19E-01
3.13E-01
3.19E-01
3.14E-01
2.98E-01
3.28E-01
2.87E-01
3.08E-01
4.17E-01
3.88E-01
168-hr
Anneal
300
3.22E-01
3.45E-01
3.27E-01
3.51E-01
3.23E-01
3.27E-01
3.20E-01
3.59E-01
3.19E-01
2.39E-01
4.40E-01
4.29E-01
3.65E-01
7.18E-03
3.85E-01
3.45E-01
3.10E-01
9.58E-03
3.36E-01
2.84E-01
3.20E-01
5.02E-03
3.34E-01
3.06E-01
3.34E-01
1.34E-02
3.70E-01
2.97E-01
3.52E-01
1.20E-02
3.85E-01
3.19E-01
7.00E-02
PASS
3.06E-01
1.43E-02
3.45E-01
2.66E-01
1.00E-02
PASS
3.07E-01
1.56E-02
3.50E-01
2.64E-01
1.00E-02
PASS
3.13E-01
4.44E-02
4.34E-01
1.91E-01
1.00E-02
PASS
0
4.18E-01
4.21E-01
4.11E-01
4.11E-01
4.21E-01
4.15E-01
4.38E-01
4.20E-01
4.05E-01
4.04E-01
4.25E-01
4.17E-01
Total
20
4.27E-01
4.20E-01
3.82E-01
3.95E-01
3.99E-01
4.13E-01
4.02E-01
4.30E-01
3.87E-01
3.91E-01
4.38E-01
4.28E-01
Dose (krad(Si))
50
100
3.65E-01 3.64E-01
3.99E-01 3.76E-01
3.90E-01 3.61E-01
3.93E-01 3.57E-01
3.95E-01 3.67E-01
3.98E-01 3.50E-01
3.69E-01 3.48E-01
4.07E-01 3.73E-01
3.77E-01 3.44E-01
4.03E-01 3.45E-01
4.29E-01 4.56E-01
4.38E-01 4.30E-01
4.16E-01
5.08E-03
4.30E-01
4.02E-01
4.05E-01
1.85E-02
4.55E-01
3.54E-01
3.88E-01
1.35E-02
4.25E-01
3.51E-01
4.16E-01
1.38E-02
4.54E-01
3.78E-01
2.00E-01
PASS
4.05E-01
1.74E-02
4.52E-01
3.57E-01
1.20E-01
PASS
3.91E-01
1.68E-02
4.37E-01
3.45E-01
1.10E-01
PASS
An ISO 9001:2008 and DLA Certified Company
52
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
0.00E+00
Negative Slew Rate1 15V (V/µs)
@ AV=1, VS=+/-15V, VCM=0V
-5.00E-02
-1.00E-01
-1.50E-01
-2.00E-01
-2.50E-01
-3.00E-01
-3.50E-01
-4.00E-01
-4.50E-01
-5.00E-01
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.23. Plot of Negative Slew Rate1 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
53
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.23. Raw data for Negative Slew Rate1 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Slew Rate1 15V (V/µs)
@ AV=1, VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
200
-3.27E-01
-3.62E-01
-3.18E-01
-3.51E-01
-3.32E-01
-3.37E-01
-3.16E-01
-3.39E-01
-2.43E-01
-3.14E-01
-4.61E-01
-4.44E-01
24-hr
Anneal
250
-3.49E-01
-3.72E-01
-3.36E-01
-3.49E-01
-3.43E-01
-3.33E-01
-3.06E-01
-3.35E-01
-3.12E-01
-3.15E-01
-4.66E-01
-4.51E-01
168-hr
Anneal
300
-3.69E-01
-3.75E-01
-3.55E-01
-3.62E-01
-3.43E-01
-3.64E-01
-3.54E-01
-3.63E-01
-3.58E-01
-3.50E-01
-4.60E-01
-4.55E-01
-3.93E-01
4.87E-03
-3.79E-01
-4.06E-01
-3.38E-01
1.80E-02
-2.89E-01
-3.87E-01
-3.50E-01
1.35E-02
-3.13E-01
-3.87E-01
-3.61E-01
1.25E-02
-3.27E-01
-3.95E-01
-3.88E-01
1.24E-02
-3.54E-01
-4.22E-01
-7.00E-02
PASS
-3.10E-01
3.91E-02
-2.03E-01
-4.17E-01
-1.00E-02
PASS
-3.20E-01
1.30E-02
-2.84E-01
-3.56E-01
-1.00E-02
PASS
-3.58E-01
5.93E-03
-3.42E-01
-3.74E-01
-1.00E-02
PASS
0
-4.45E-01
-4.86E-01
-4.43E-01
-4.14E-01
-4.31E-01
-4.44E-01
-4.25E-01
-4.77E-01
-4.38E-01
-4.29E-01
-4.56E-01
-4.57E-01
Total
20
-4.28E-01
-4.77E-01
-4.19E-01
-4.04E-01
-4.26E-01
-4.13E-01
-4.19E-01
-4.77E-01
-4.21E-01
-4.29E-01
-4.35E-01
-4.36E-01
Dose (krad(Si))
50
100
-4.19E-01 -3.94E-01
-4.25E-01 -3.92E-01
-3.86E-01 -3.95E-01
-4.03E-01 -3.98E-01
-4.29E-01 -3.85E-01
-3.96E-01 -4.07E-01
-4.17E-01 -3.89E-01
-4.43E-01 -3.91E-01
-4.10E-01 -3.77E-01
-4.04E-01 -3.77E-01
-4.72E-01 -4.34E-01
-4.42E-01 -4.68E-01
-4.44E-01
2.66E-02
-3.71E-01
-5.17E-01
-4.31E-01
2.75E-02
-3.55E-01
-5.06E-01
-4.12E-01
1.78E-02
-3.64E-01
-4.61E-01
-4.43E-01
2.06E-02
-3.86E-01
-4.99E-01
-2.00E-01
PASS
-4.32E-01
2.59E-02
-3.61E-01
-5.03E-01
-1.20E-01
PASS
-4.14E-01
1.80E-02
-3.65E-01
-4.63E-01
-1.10E-01
PASS
An ISO 9001:2008 and DLA Certified Company
54
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
0.00E+00
Negative Slew Rate2 15V (V/µs)
@ AV=1, VS=+/-15V, VCM=0V
-1.00E-01
-2.00E-01
-3.00E-01
-4.00E-01
-5.00E-01
-6.00E-01
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.24. Plot of Negative Slew Rate2 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL
statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the upper
and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
55
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.24. Raw data for Negative Slew Rate2 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Slew Rate2 15V (V/µs)
@ AV=1, VS=+/-15V, VCM=0V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
200
-3.58E-01
-3.70E-01
-3.45E-01
-3.54E-01
-3.59E-01
-3.69E-01
-3.42E-01
-3.63E-01
-3.45E-01
-3.55E-01
-4.76E-01
-4.71E-01
24-hr
Anneal
250
-3.52E-01
-3.91E-01
-3.63E-01
-3.68E-01
-3.73E-01
-3.39E-01
-3.40E-01
-3.71E-01
-3.40E-01
-3.41E-01
-4.72E-01
-4.58E-01
168-hr
Anneal
300
-4.01E-01
-4.23E-01
-3.59E-01
-3.98E-01
-3.97E-01
-3.70E-01
-3.68E-01
-3.90E-01
-3.76E-01
-3.87E-01
-4.91E-01
-4.73E-01
-4.16E-01
7.23E-03
-3.96E-01
-4.35E-01
-3.57E-01
9.04E-03
-3.32E-01
-3.82E-01
-3.69E-01
1.44E-02
-3.30E-01
-4.09E-01
-3.96E-01
2.31E-02
-3.32E-01
-4.59E-01
-4.11E-01
2.71E-02
-3.36E-01
-4.85E-01
-7.00E-02
PASS
-3.55E-01
1.15E-02
-3.23E-01
-3.86E-01
-1.00E-02
PASS
-3.46E-01
1.39E-02
-3.08E-01
-3.84E-01
-1.00E-02
PASS
-3.78E-01
9.91E-03
-3.51E-01
-4.05E-01
-1.00E-02
PASS
0
-4.90E-01
-4.71E-01
-4.87E-01
-4.59E-01
-4.38E-01
-4.74E-01
-4.73E-01
-5.55E-01
-4.57E-01
-4.32E-01
-4.66E-01
-4.60E-01
Total
20
-4.51E-01
-4.64E-01
-4.68E-01
-4.44E-01
-4.69E-01
-4.58E-01
-4.67E-01
-4.87E-01
-4.53E-01
-4.68E-01
-4.80E-01
-4.63E-01
Dose (krad(Si))
50
100
-4.47E-01 -4.24E-01
-4.45E-01 -4.05E-01
-4.01E-01 -4.13E-01
-4.30E-01 -4.20E-01
-4.52E-01 -4.16E-01
-4.24E-01 -4.34E-01
-4.37E-01 -4.01E-01
-4.53E-01 -4.44E-01
-4.48E-01 -3.81E-01
-4.25E-01 -3.93E-01
-4.50E-01 -4.66E-01
-4.70E-01 -4.79E-01
-4.69E-01
2.14E-02
-4.10E-01
-5.28E-01
-4.59E-01
1.11E-02
-4.29E-01
-4.90E-01
-4.35E-01
2.07E-02
-3.78E-01
-4.92E-01
-4.78E-01
4.62E-02
-3.52E-01
-6.05E-01
-2.00E-01
PASS
-4.67E-01
1.30E-02
-4.31E-01
-5.02E-01
-1.20E-01
PASS
-4.37E-01
1.31E-02
-4.01E-01
-4.73E-01
-1.10E-01
PASS
An ISO 9001:2008 and DLA Certified Company
56
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Positive Supply Current 5V (A)
@ +VS=5V, -VS=0V, VCM=0V, VOUT=4V
1.20E-03
1.00E-03
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.25. Plot of Positive Supply Current 5V (A) @ +VS=5V, -VS=0V, VCM=0V, VOUT=4V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
57
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.25. Raw data for Positive Supply Current 5V (A) @ +VS=5V, -VS=0V, VCM=0V, VOUT=4V versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Supply Current 5V (A)
@ +VS=5V, -VS=0V, VCM=0V, VOUT=4V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
200
4.49E-04
4.50E-04
4.51E-04
4.63E-04
4.67E-04
4.46E-04
4.55E-04
4.31E-04
4.57E-04
4.61E-04
7.15E-04
7.12E-04
24-hr
Anneal
250
4.57E-04
4.53E-04
4.55E-04
4.68E-04
4.70E-04
4.38E-04
4.45E-04
4.26E-04
4.47E-04
4.50E-04
7.13E-04
7.13E-04
168-hr
Anneal
300
4.67E-04
4.74E-04
4.72E-04
4.80E-04
4.80E-04
4.53E-04
4.59E-04
4.44E-04
4.67E-04
4.65E-04
7.16E-04
7.13E-04
5.77E-04
8.57E-06
6.01E-04
5.53E-04
4.56E-04
8.37E-06
4.79E-04
4.33E-04
4.61E-04
7.83E-06
4.82E-04
4.39E-04
4.75E-04
5.55E-06
4.90E-04
4.59E-04
5.85E-04
1.25E-05
6.20E-04
5.51E-04
1.00E-03
PASS
4.50E-04
1.20E-05
4.83E-04
4.17E-04
1.00E-03
PASS
4.41E-04
9.58E-06
4.67E-04
4.15E-04
1.00E-03
PASS
4.58E-04
9.37E-06
4.83E-04
4.32E-04
1.00E-03
PASS
0
7.10E-04
7.06E-04
7.13E-04
7.16E-04
7.28E-04
7.13E-04
7.11E-04
7.11E-04
7.27E-04
7.18E-04
7.17E-04
7.12E-04
Total
20
6.97E-04
6.99E-04
7.01E-04
7.01E-04
7.04E-04
7.18E-04
7.24E-04
7.21E-04
7.36E-04
7.31E-04
7.15E-04
7.15E-04
Dose (krad(Si))
50
100
6.72E-04 5.72E-04
6.70E-04 5.69E-04
6.72E-04 5.72E-04
6.78E-04 5.83E-04
6.82E-04 5.89E-04
6.76E-04 5.81E-04
6.81E-04 5.88E-04
6.74E-04 5.67E-04
6.89E-04 5.90E-04
6.89E-04 6.01E-04
7.16E-04 7.15E-04
7.11E-04 7.13E-04
7.15E-04
8.35E-06
7.38E-04
6.92E-04
7.00E-04
2.61E-06
7.08E-04
6.93E-04
6.75E-04
5.02E-06
6.89E-04
6.61E-04
7.16E-04
6.78E-06
7.35E-04
6.97E-04
1.00E-03
PASS
7.26E-04
7.38E-06
7.46E-04
7.06E-04
1.00E-03
PASS
6.82E-04
7.05E-06
7.01E-04
6.62E-04
1.00E-03
PASS
An ISO 9001:2008 and DLA Certified Company
58
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Negative Supply Current 5V (A)
@ +VS=5V, -VS=0V, VCM=0V, VOUT=4V
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
-1.20E-03
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.26. Plot of Negative Supply Current 5V (A) @ +VS=5V, -VS=0V, VCM=0V, VOUT=4V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
59
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.26. Raw data for Negative Supply Current 5V (A) @ +VS=5V, -VS=0V, VCM=0V, VOUT=4V versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Supply Current 5V (A)
@ +VS=5V, -VS=0V, VCM=0V, VOUT=4V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
-4.33E-04
-4.35E-04
-4.37E-04
-4.47E-04
-4.52E-04
-4.31E-04
-4.40E-04
-4.13E-04
-4.40E-04
-4.44E-04
-7.01E-04
-6.95E-04
24-hr
Anneal
250
-4.39E-04
-4.37E-04
-4.41E-04
-4.51E-04
-4.55E-04
-4.23E-04
-4.30E-04
-4.10E-04
-4.32E-04
-4.34E-04
-7.02E-04
-6.96E-04
168-hr
Anneal
300
-4.54E-04
-4.61E-04
-4.57E-04
-4.63E-04
-4.63E-04
-4.40E-04
-4.44E-04
-4.27E-04
-4.52E-04
-4.49E-04
-7.02E-04
-6.95E-04
-5.62E-04
9.10E-06
-5.37E-04
-5.87E-04
-4.41E-04
8.26E-06
-4.18E-04
-4.63E-04
-4.45E-04
7.92E-06
-4.23E-04
-4.66E-04
-4.60E-04
3.97E-06
-4.49E-04
-4.70E-04
-5.70E-04
1.21E-05
-5.37E-04
-6.04E-04
-1.00E-03
PASS
-4.34E-04
1.25E-05
-3.99E-04
-4.68E-04
-1.00E-03
PASS
-4.26E-04
9.76E-06
-3.99E-04
-4.53E-04
-1.00E-03
PASS
-4.42E-04
9.76E-06
-4.16E-04
-4.69E-04
-1.00E-03
PASS
0
-6.97E-04
-6.93E-04
-7.00E-04
-7.00E-04
-7.12E-04
-6.96E-04
-6.96E-04
-6.96E-04
-7.12E-04
-7.02E-04
-7.02E-04
-6.96E-04
Total
20
-6.83E-04
-6.81E-04
-6.88E-04
-6.88E-04
-6.92E-04
-7.04E-04
-7.09E-04
-7.04E-04
-7.20E-04
-7.17E-04
-7.02E-04
-6.97E-04
Dose (krad(Si))
50
100
-6.56E-04 -5.57E-04
-6.53E-04 -5.54E-04
-6.56E-04 -5.55E-04
-6.61E-04 -5.67E-04
-6.67E-04 -5.75E-04
-6.61E-04 -5.66E-04
-6.66E-04 -5.73E-04
-6.56E-04 -5.53E-04
-6.75E-04 -5.74E-04
-6.74E-04 -5.86E-04
-7.01E-04 -7.01E-04
-6.97E-04 -6.97E-04
-7.00E-04
7.09E-06
-6.81E-04
-7.20E-04
-6.86E-04
4.39E-06
-6.74E-04
-6.98E-04
-6.59E-04
5.50E-06
-6.44E-04
-6.74E-04
-7.00E-04
6.99E-06
-6.81E-04
-7.20E-04
-1.00E-03
PASS
-7.11E-04
7.40E-06
-6.91E-04
-7.31E-04
-1.00E-03
PASS
-6.66E-04
8.20E-06
-6.44E-04
-6.89E-04
-1.00E-03
PASS
An ISO 9001:2008 and DLA Certified Company
60
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Input Offset Voltage1 5V (V)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.27. Plot of Input Offset Voltage1 5V (V) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
61
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.27. Raw data for Input Offset Voltage1 5V (V) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage1 5V (V)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
200
2.97E-04
9.78E-05
2.19E-04
1.95E-04
2.65E-04
2.72E-04
3.01E-04
2.03E-04
3.29E-04
3.29E-04
2.76E-05
3.56E-05
24-hr
Anneal
250
2.18E-04
8.47E-05
1.92E-04
1.58E-04
2.20E-04
2.08E-04
2.31E-04
1.47E-04
2.62E-04
2.73E-04
2.76E-05
3.68E-05
168-hr
Anneal
300
5.74E-05
2.16E-06
5.93E-05
6.09E-05
9.67E-05
5.64E-05
5.29E-05
7.92E-05
5.12E-05
6.97E-05
2.81E-05
3.63E-05
3.14E-05
3.97E-05
1.40E-04
-7.74E-05
2.15E-04
7.64E-05
4.24E-04
5.22E-06
1.74E-04
5.60E-05
3.28E-04
2.09E-05
5.53E-05
3.39E-05
1.48E-04
-3.76E-05
5.42E-05
1.63E-05
9.89E-05
9.36E-06
-9.00E-04
PASS
9.00E-04
PASS
2.87E-04
5.22E-05
4.30E-04
1.44E-04
-9.00E-04
PASS
9.00E-04
PASS
2.24E-04
5.01E-05
3.62E-04
8.66E-05
-9.00E-04
PASS
9.00E-04
PASS
6.18E-05
1.21E-05
9.50E-05
2.86E-05
-9.00E-04
PASS
9.00E-04
PASS
0
-5.68E-05
-7.39E-05
-1.74E-05
-5.61E-05
-2.04E-05
-2.31E-05
-4.65E-05
-6.46E-06
-6.50E-05
-3.18E-05
2.74E-05
3.54E-05
Total
20
-6.32E-05
-8.11E-05
-2.14E-05
-5.89E-05
-2.26E-05
-3.02E-05
-4.98E-05
-1.72E-05
-7.04E-05
-3.58E-05
2.69E-05
3.44E-05
Dose (krad(Si))
50
100
-3.77E-05 1.78E-05
-6.76E-05 -2.57E-05
1.62E-06 6.65E-05
-3.72E-05 2.68E-05
9.64E-06 7.15E-05
-1.68E-05 5.28E-05
-2.93E-05 4.58E-05
-9.24E-06 3.54E-05
-3.92E-05 5.75E-05
-9.72E-06 7.93E-05
2.69E-05 2.68E-05
3.55E-05 3.44E-05
-4.49E-05
2.48E-05
2.31E-05
-1.13E-04
-4.94E-05
2.64E-05
2.29E-05
-1.22E-04
-2.62E-05
3.17E-05
6.07E-05
-1.13E-04
-3.46E-05
2.24E-05
2.68E-05
-9.59E-05
-4.50E-04
PASS
4.50E-04
PASS
-4.07E-05
2.03E-05
1.50E-05
-9.64E-05
-6.00E-04
PASS
6.00E-04
PASS
-2.08E-05
1.30E-05
1.49E-05
-5.66E-05
-7.50E-04
PASS
7.50E-04
PASS
An ISO 9001:2008 and DLA Certified Company
62
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Input Offset Voltage2 5V (V)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.28. Plot of Input Offset Voltage2 5V (V) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
63
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.28. Raw data for Input Offset Voltage2 5V (V) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage2 5V (V)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
200
4.04E-04
9.28E-05
2.00E-04
2.55E-04
1.94E-04
3.94E-04
3.60E-04
1.96E-04
3.60E-04
4.45E-04
3.41E-05
2.54E-05
24-hr
Anneal
250
3.00E-04
6.74E-05
1.45E-04
2.11E-04
8.12E-05
3.41E-04
2.89E-04
1.44E-04
2.93E-04
3.77E-04
3.16E-05
2.32E-05
168-hr
Anneal
300
1.24E-04
-1.05E-05
2.32E-05
1.01E-04
-4.90E-07
1.41E-04
6.47E-05
3.37E-05
5.98E-05
1.51E-04
3.30E-05
2.53E-05
5.01E-05
5.67E-05
2.05E-04
-1.05E-04
2.29E-04
1.14E-04
5.41E-04
-8.29E-05
1.61E-04
9.64E-05
4.25E-04
-1.04E-04
4.74E-05
6.11E-05
2.15E-04
-1.20E-04
1.06E-04
6.58E-05
2.87E-04
-7.42E-05
-9.00E-04
PASS
9.00E-04
PASS
3.51E-04
9.33E-05
6.07E-04
9.54E-05
-9.00E-04
PASS
9.00E-04
PASS
2.89E-04
8.89E-05
5.32E-04
4.50E-05
-9.00E-04
PASS
9.00E-04
PASS
9.01E-05
5.26E-05
2.34E-04
-5.42E-05
-9.00E-04
PASS
9.00E-04
PASS
0
1.58E-05
-5.83E-05
-5.29E-05
1.80E-05
-8.55E-05
5.82E-05
-4.35E-05
-4.41E-05
-6.05E-05
4.01E-05
3.26E-05
2.51E-05
Total
20
1.39E-05
-6.78E-05
-4.62E-05
2.03E-05
-8.70E-05
5.73E-05
-4.78E-05
-5.18E-05
-5.77E-05
4.44E-05
3.24E-05
2.21E-05
Dose (krad(Si))
50
100
4.45E-05 1.15E-04
-4.80E-05 -1.51E-05
-2.20E-05 3.30E-05
4.51E-05 1.03E-04
-5.21E-05 1.43E-05
8.58E-05 1.66E-04
-6.76E-06 8.78E-05
-4.39E-05 1.30E-05
-2.05E-05 9.13E-05
8.40E-05 1.73E-04
3.28E-05 3.21E-05
2.43E-05 2.33E-05
-3.26E-05
4.68E-05
9.59E-05
-1.61E-04
-3.34E-05
4.83E-05
9.91E-05
-1.66E-04
-6.50E-06
4.82E-05
1.26E-04
-1.39E-04
-9.94E-06
5.47E-05
1.40E-04
-1.60E-04
-4.50E-04
PASS
4.50E-04
PASS
-1.11E-05
5.69E-05
1.45E-04
-1.67E-04
-6.00E-04
PASS
6.00E-04
PASS
1.97E-05
6.09E-05
1.87E-04
-1.47E-04
-7.50E-04
PASS
7.50E-04
PASS
An ISO 9001:2008 and DLA Certified Company
64
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Input Offset Current1 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
-2.50E-08
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.29. Plot of Input Offset Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
65
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.29. Raw data for Input Offset Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current1 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
200
1.91E-09
2.01E-10
-8.80E-11
-2.87E-10
8.28E-10
4.46E-10
2.15E-10
-2.40E-10
3.85E-10
6.93E-10
3.00E-11
-1.80E-11
24-hr
Anneal
250
1.01E-09
7.00E-11
3.40E-11
-1.00E-10
7.40E-10
4.25E-10
9.60E-11
-2.17E-10
1.64E-10
4.87E-10
4.00E-11
-1.20E-11
168-hr
Anneal
300
7.13E-10
-5.00E-12
3.90E-11
-2.48E-10
1.38E-10
-1.69E-10
1.03E-10
-1.29E-10
-8.60E-11
1.49E-10
1.60E-11
-1.30E-11
2.44E-11
1.69E-10
4.88E-10
-4.39E-10
5.12E-10
8.86E-10
2.94E-09
-1.92E-09
3.50E-10
4.91E-10
1.70E-09
-9.97E-10
1.27E-10
3.57E-10
1.11E-09
-8.51E-10
8.64E-11
3.24E-10
9.74E-10
-8.01E-10
-2.00E-08
PASS
2.00E-08
PASS
3.00E-10
3.47E-10
1.25E-09
-6.52E-10
-2.00E-08
PASS
2.00E-08
PASS
1.91E-10
2.82E-10
9.65E-10
-5.83E-10
-2.00E-08
PASS
2.00E-08
PASS
-2.64E-11
1.43E-10
3.66E-10
-4.19E-10
-2.00E-08
PASS
2.00E-08
PASS
0
4.70E-11
2.40E-11
9.40E-11
-2.20E-11
1.28E-10
1.20E-11
-8.80E-11
-7.80E-11
3.10E-11
-2.00E-11
4.30E-11
2.90E-11
Total
20
-4.80E-11
-7.80E-11
2.10E-11
-1.32E-10
6.00E-11
-2.70E-11
-3.10E-11
-1.17E-10
7.80E-11
-3.80E-11
7.00E-12
2.80E-11
Dose (krad(Si))
50
100
-3.80E-11 1.04E-10
-1.19E-10 -1.70E-11
1.03E-10 -4.30E-11
-2.20E-10 -1.86E-10
1.48E-10 2.64E-10
5.50E-11 7.80E-11
5.40E-11 -8.00E-12
-1.65E-10 -3.87E-10
2.04E-10 2.75E-10
3.30E-11 4.74E-10
4.50E-11 3.20E-11
-1.50E-11 -1.40E-11
5.42E-11
5.87E-11
2.15E-10
-1.07E-10
-3.54E-11
7.68E-11
1.75E-10
-2.46E-10
-2.52E-11
1.53E-10
3.94E-10
-4.44E-10
-2.86E-11
5.30E-11
1.17E-10
-1.74E-10
-1.00E-08
PASS
1.00E-08
PASS
-2.70E-11
6.94E-11
1.63E-10
-2.17E-10
-1.00E-08
PASS
1.00E-08
PASS
3.62E-11
1.32E-10
3.97E-10
-3.25E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DLA Certified Company
66
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Input Offset Current2 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
-2.50E-08
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.30. Plot of Input Offset Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
67
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.30. Raw data for Input Offset Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current2 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
200
2.36E-09
3.25E-10
2.29E-10
4.54E-10
9.19E-10
1.22E-10
1.55E-10
-6.49E-10
6.75E-10
2.99E-10
-3.80E-11
-1.40E-11
24-hr
Anneal
250
1.39E-09
1.04E-10
2.45E-10
2.95E-10
6.23E-10
-7.75E-10
-3.36E-10
-1.31E-09
8.00E-11
-9.20E-11
-4.20E-11
-1.70E-11
168-hr
Anneal
300
6.59E-10
-1.29E-10
1.70E-10
1.79E-10
4.50E-11
-2.63E-10
2.69E-10
1.42E-10
2.76E-10
-7.30E-11
-4.00E-11
8.00E-12
-3.82E-11
1.55E-10
3.86E-10
-4.63E-10
8.57E-10
8.80E-10
3.27E-09
-1.56E-09
5.31E-10
5.15E-10
1.94E-09
-8.82E-10
1.85E-10
2.93E-10
9.88E-10
-6.18E-10
-4.00E-10
3.10E-10
4.51E-10
-1.25E-09
-2.00E-08
PASS
2.00E-08
PASS
1.20E-10
4.83E-10
1.44E-09
-1.20E-09
-2.00E-08
PASS
2.00E-08
PASS
-4.87E-10
5.62E-10
1.06E-09
-2.03E-09
-2.00E-08
PASS
2.00E-08
PASS
7.02E-11
2.34E-10
7.11E-10
-5.71E-10
-2.00E-08
PASS
2.00E-08
PASS
0
-1.00E-11
-5.80E-11
-1.15E-10
-5.50E-11
-1.09E-10
-4.70E-11
-4.30E-11
0.00E+00
-2.50E-11
-3.20E-11
-4.30E-11
5.00E-12
Total
20
-2.07E-10
-8.60E-11
-3.11E-10
-1.70E-10
-1.70E-10
-2.63E-10
-2.69E-10
-1.57E-10
-2.20E-10
-8.00E-11
-4.80E-11
0.00E+00
Dose (krad(Si))
50
100
-1.36E-10 -7.00E-12
-1.17E-10 -1.55E-10
-2.04E-10 -1.71E-10
-3.23E-10 -7.00E-11
3.40E-11 2.12E-10
-2.57E-10 -4.14E-10
-3.66E-10 -2.59E-10
-4.58E-10 -9.31E-10
-1.76E-10 -2.29E-10
-2.39E-10 -1.67E-10
-3.40E-11 -1.50E-11
-5.00E-12 -2.80E-11
-6.94E-11
4.33E-11
4.94E-11
-1.88E-10
-1.89E-10
8.15E-11
3.45E-11
-4.12E-10
-1.49E-10
1.30E-10
2.08E-10
-5.07E-10
-2.94E-11
1.86E-11
2.16E-11
-8.04E-11
-1.00E-08
PASS
1.00E-08
PASS
-1.98E-10
7.96E-11
2.05E-11
-4.16E-10
-1.00E-08
PASS
1.00E-08
PASS
-2.99E-10
1.12E-10
8.17E-12
-6.07E-10
-1.50E-08
PASS
1.50E-08
PASS
An ISO 9001:2008 and DLA Certified Company
68
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Input Bias Current1 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.31. Plot of Positive Input Bias Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus
total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
69
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.31. Raw data for Positive Input Bias Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Input Bias Current1 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
Dose (krad(Si))
50
100
2.33E-08 3.85E-08
2.32E-08 3.74E-08
2.35E-08 3.77E-08
2.39E-08 3.82E-08
2.25E-08 3.54E-08
2.26E-08 3.59E-08
2.40E-08 3.79E-08
2.38E-08 3.84E-08
2.39E-08 3.76E-08
2.24E-08 3.54E-08
9.59E-09 9.57E-09
9.68E-09 9.69E-09
200
6.40E-08
6.15E-08
6.26E-08
6.32E-08
5.86E-08
5.96E-08
6.26E-08
6.30E-08
6.09E-08
5.91E-08
9.55E-09
9.69E-09
24-hr
Anneal
250
6.34E-08
6.14E-08
6.27E-08
6.34E-08
5.92E-08
5.52E-08
5.81E-08
5.78E-08
5.65E-08
5.49E-08
9.54E-09
9.68E-09
168-hr
Anneal
300
4.65E-08
4.63E-08
4.84E-08
4.96E-08
4.59E-08
3.92E-08
4.18E-08
4.08E-08
4.09E-08
3.95E-08
9.56E-09
9.71E-09
0
1.02E-08
1.00E-08
1.06E-08
1.11E-08
1.03E-08
1.01E-08
1.10E-08
1.04E-08
1.10E-08
1.03E-08
9.59E-09
9.67E-09
Total
20
1.46E-08
1.49E-08
1.53E-08
1.58E-08
1.47E-08
1.46E-08
1.57E-08
1.53E-08
1.56E-08
1.48E-08
9.57E-09
9.69E-09
1.04E-08
4.45E-10
1.16E-08
9.21E-09
1.51E-08
4.78E-10
1.64E-08
1.37E-08
2.32E-08
5.17E-10
2.47E-08
2.18E-08
3.74E-08
1.20E-09
4.07E-08
3.41E-08
6.20E-08
2.10E-09
6.77E-08
5.62E-08
6.20E-08
1.78E-09
6.69E-08
5.71E-08
4.73E-08
1.60E-09
5.17E-08
4.29E-08
1.06E-08
4.12E-10
1.17E-08
9.43E-09
-5.00E-08
PASS
5.00E-08
PASS
1.52E-08
4.87E-10
1.65E-08
1.38E-08
-1.00E-07
PASS
1.00E-07
PASS
2.33E-08
7.81E-10
2.55E-08
2.12E-08
-1.25E-07
PASS
1.25E-07
PASS
3.70E-08
1.30E-09
4.06E-08
3.35E-08
-2.00E-07
PASS
2.00E-07
PASS
6.11E-08
1.74E-09
6.58E-08
5.63E-08
-2.00E-07
PASS
2.00E-07
PASS
5.65E-08
1.47E-09
6.05E-08
5.25E-08
-2.00E-07
PASS
2.00E-07
PASS
4.04E-08
1.09E-09
4.34E-08
3.75E-08
-2.00E-07
PASS
2.00E-07
PASS
An ISO 9001:2008 and DLA Certified Company
70
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Input Bias Current2 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.32. Plot of Positive Input Bias Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus
total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
71
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.32. Raw data for Positive Input Bias Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Input Bias Current2 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
Dose (krad(Si))
50
100
2.51E-08 4.13E-08
2.27E-08 3.68E-08
2.44E-08 3.92E-08
2.36E-08 3.77E-08
2.34E-08 3.65E-08
2.48E-08 3.91E-08
2.49E-08 3.91E-08
2.49E-08 3.98E-08
2.51E-08 3.94E-08
2.48E-08 3.93E-08
1.06E-08 1.06E-08
1.06E-08 1.05E-08
200
6.81E-08
6.04E-08
6.46E-08
6.17E-08
6.03E-08
6.42E-08
6.42E-08
6.47E-08
6.31E-08
6.46E-08
1.06E-08
1.06E-08
24-hr
Anneal
250
6.74E-08
6.04E-08
6.51E-08
6.20E-08
6.09E-08
6.03E-08
6.03E-08
6.03E-08
5.91E-08
6.07E-08
1.06E-08
1.06E-08
168-hr
Anneal
300
5.00E-08
4.55E-08
5.04E-08
4.86E-08
4.75E-08
4.25E-08
4.29E-08
4.18E-08
4.26E-08
4.38E-08
1.06E-08
1.06E-08
0
1.10E-08
9.84E-09
1.09E-08
1.10E-08
1.07E-08
1.11E-08
1.12E-08
1.08E-08
1.14E-08
1.14E-08
1.06E-08
1.06E-08
Total
20
1.60E-08
1.46E-08
1.60E-08
1.57E-08
1.54E-08
1.60E-08
1.62E-08
1.59E-08
1.64E-08
1.63E-08
1.06E-08
1.06E-08
1.07E-08
4.97E-10
1.21E-08
9.34E-09
1.55E-08
5.77E-10
1.71E-08
1.39E-08
2.38E-08
9.45E-10
2.64E-08
2.12E-08
3.83E-08
1.99E-09
4.38E-08
3.29E-08
6.30E-08
3.34E-09
7.22E-08
5.39E-08
6.31E-08
2.97E-09
7.13E-08
5.50E-08
4.84E-08
1.99E-09
5.38E-08
4.29E-08
1.12E-08
2.62E-10
1.19E-08
1.04E-08
-5.00E-08
PASS
5.00E-08
PASS
1.62E-08
2.13E-10
1.67E-08
1.56E-08
-1.00E-07
PASS
1.00E-07
PASS
2.49E-08
1.05E-10
2.52E-08
2.46E-08
-1.25E-07
PASS
1.25E-07
PASS
3.93E-08
2.79E-10
4.01E-08
3.86E-08
-2.00E-07
PASS
2.00E-07
PASS
6.41E-08
6.05E-10
6.58E-08
6.25E-08
-2.00E-07
PASS
2.00E-07
PASS
6.01E-08
5.93E-10
6.18E-08
5.85E-08
-2.00E-07
PASS
2.00E-07
PASS
4.27E-08
7.00E-10
4.46E-08
4.08E-08
-2.00E-07
PASS
2.00E-07
PASS
An ISO 9001:2008 and DLA Certified Company
72
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Negative Input Bias Current1 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.33. Plot of Negative Input Bias Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus
total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
73
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.33. Raw data for Negative Input Bias Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Input Bias Current1 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
Dose (krad(Si))
50
100
2.32E-08 3.86E-08
2.31E-08 3.74E-08
2.36E-08 3.77E-08
2.37E-08 3.81E-08
2.27E-08 3.58E-08
2.27E-08 3.61E-08
2.41E-08 3.80E-08
2.37E-08 3.80E-08
2.41E-08 3.79E-08
2.25E-08 3.59E-08
9.62E-09 9.63E-09
9.73E-09 9.73E-09
200
6.60E-08
6.17E-08
6.26E-08
6.30E-08
5.95E-08
6.02E-08
6.29E-08
6.29E-08
6.13E-08
5.98E-08
9.60E-09
9.70E-09
24-hr
Anneal
250
6.45E-08
6.15E-08
6.28E-08
6.34E-08
6.00E-08
5.57E-08
5.84E-08
5.77E-08
5.67E-08
5.55E-08
9.62E-09
9.72E-09
168-hr
Anneal
300
4.72E-08
4.63E-08
4.86E-08
4.95E-08
4.61E-08
3.91E-08
4.20E-08
4.06E-08
4.09E-08
3.96E-08
9.65E-09
9.70E-09
0
1.01E-08
1.00E-08
1.07E-08
1.11E-08
1.04E-08
1.01E-08
1.09E-08
1.03E-08
1.11E-08
1.03E-08
9.63E-09
9.69E-09
Total
20
1.46E-08
1.48E-08
1.53E-08
1.57E-08
1.48E-08
1.46E-08
1.56E-08
1.51E-08
1.58E-08
1.47E-08
9.62E-09
9.73E-09
1.05E-08
4.35E-10
1.17E-08
9.27E-09
1.51E-08
4.42E-10
1.63E-08
1.38E-08
2.33E-08
4.07E-10
2.44E-08
2.21E-08
3.75E-08
1.07E-09
4.05E-08
3.46E-08
6.26E-08
2.36E-09
6.91E-08
5.61E-08
6.25E-08
1.74E-09
6.72E-08
5.77E-08
4.75E-08
1.46E-09
5.15E-08
4.35E-08
1.05E-08
4.04E-10
1.16E-08
9.42E-09
-5.00E-08
PASS
5.00E-08
PASS
1.52E-08
5.17E-10
1.66E-08
1.38E-08
-1.00E-07
PASS
1.00E-07
PASS
2.34E-08
7.62E-10
2.55E-08
2.13E-08
-1.25E-07
PASS
1.25E-07
PASS
3.72E-08
1.09E-09
4.02E-08
3.42E-08
-2.00E-07
PASS
2.00E-07
PASS
6.14E-08
1.44E-09
6.54E-08
5.75E-08
-2.00E-07
PASS
2.00E-07
PASS
5.68E-08
1.24E-09
6.02E-08
5.34E-08
-2.00E-07
PASS
2.00E-07
PASS
4.05E-08
1.14E-09
4.36E-08
3.74E-08
-2.00E-07
PASS
2.00E-07
PASS
An ISO 9001:2008 and DLA Certified Company
74
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Negative Input Bias Current2 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.34. Plot of Negative Input Bias Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V versus
total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
75
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.34. Raw data for Negative Input Bias Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Input Bias Current2 5V (A)
@ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Status
Dose (krad(Si))
50
100
2.50E-08 4.14E-08
2.26E-08 3.67E-08
2.42E-08 3.91E-08
2.33E-08 3.77E-08
2.34E-08 3.69E-08
2.46E-08 3.88E-08
2.46E-08 3.90E-08
2.44E-08 3.89E-08
2.49E-08 3.92E-08
2.46E-08 3.92E-08
1.06E-08 1.06E-08
1.06E-08 1.06E-08
200
7.06E-08
6.08E-08
6.49E-08
6.22E-08
6.13E-08
6.44E-08
6.44E-08
6.42E-08
6.39E-08
6.50E-08
1.06E-08
1.06E-08
24-hr
Anneal
250
6.89E-08
6.07E-08
6.54E-08
6.24E-08
6.16E-08
5.96E-08
6.01E-08
5.91E-08
5.92E-08
6.07E-08
1.06E-08
1.06E-08
168-hr
Anneal
300
5.07E-08
4.54E-08
5.07E-08
4.89E-08
4.77E-08
4.23E-08
4.33E-08
4.20E-08
4.29E-08
4.37E-08
1.06E-08
1.06E-08
0
1.10E-08
9.75E-09
1.08E-08
1.10E-08
1.06E-08
1.10E-08
1.11E-08
1.07E-08
1.14E-08
1.15E-08
1.06E-08
1.06E-08
Total
20
1.58E-08
1.45E-08
1.57E-08
1.55E-08
1.52E-08
1.58E-08
1.60E-08
1.57E-08
1.63E-08
1.63E-08
1.06E-08
1.06E-08
1.06E-08
5.24E-10
1.21E-08
9.20E-09
1.53E-08
5.24E-10
1.68E-08
1.39E-08
2.37E-08
9.35E-10
2.63E-08
2.11E-08
3.83E-08
1.97E-09
4.37E-08
3.30E-08
6.40E-08
4.02E-09
7.50E-08
5.29E-08
6.38E-08
3.36E-09
7.30E-08
5.46E-08
4.87E-08
2.22E-09
5.48E-08
4.26E-08
1.12E-08
3.09E-10
1.20E-08
1.03E-08
-5.00E-08
PASS
5.00E-08
PASS
1.60E-08
2.50E-10
1.67E-08
1.53E-08
-1.00E-07
PASS
1.00E-07
PASS
2.46E-08
1.88E-10
2.51E-08
2.41E-08
-1.25E-07
PASS
1.25E-07
PASS
3.90E-08
1.96E-10
3.96E-08
3.85E-08
-2.00E-07
PASS
2.00E-07
PASS
6.44E-08
3.89E-10
6.55E-08
6.33E-08
-2.00E-07
PASS
2.00E-07
PASS
5.97E-08
6.72E-10
6.16E-08
5.79E-08
-2.00E-07
PASS
2.00E-07
PASS
4.28E-08
7.09E-10
4.48E-08
4.09E-08
-2.00E-07
PASS
2.00E-07
PASS
An ISO 9001:2008 and DLA Certified Company
76
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage High 5V Open 1 (V)
@ +VS=+5V, -VS=0V, VCM=0V, No Load
4.35E+00
4.30E+00
4.25E+00
4.20E+00
4.15E+00
4.10E+00
4.05E+00
4.00E+00
3.95E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.35. Plot of Positive Output Voltage High 5V Open 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
77
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.35. Raw data for Positive Output Voltage High 5V Open 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, No
Load versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage High 5V Open 1 (V)
@ +VS=+5V, -VS=0V, VCM=0V, No Load
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.31E+00
4.31E+00
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.26E+00
4.26E+00
24-hr
Anneal
250
4.31E+00
4.31E+00
4.31E+00
4.31E+00
4.31E+00
4.31E+00
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.27E+00
4.26E+00
168-hr
Anneal
300
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.31E+00
4.31E+00
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.27E+00
4.27E+00
4.31E+00
4.62E-03
4.32E+00
4.30E+00
4.31E+00
3.77E-03
4.32E+00
4.30E+00
4.31E+00
2.86E-03
4.32E+00
4.30E+00
4.31E+00
4.00E-03
4.32E+00
4.30E+00
4.31E+00
3.94E-03
4.32E+00
4.30E+00
4.00E+00
PASS
4.31E+00
4.15E-03
4.32E+00
4.30E+00
4.00E+00
PASS
4.31E+00
4.53E-03
4.32E+00
4.30E+00
4.00E+00
PASS
4.31E+00
4.53E-03
4.32E+00
4.30E+00
4.00E+00
PASS
0
4.26E+00
4.27E+00
4.26E+00
4.26E+00
4.26E+00
4.27E+00
4.26E+00
4.27E+00
4.26E+00
4.26E+00
4.27E+00
4.26E+00
Total
20
4.26E+00
4.27E+00
4.26E+00
4.26E+00
4.26E+00
4.26E+00
4.25E+00
4.26E+00
4.25E+00
4.25E+00
4.26E+00
4.26E+00
Dose (krad(Si))
50
100
4.27E+00 4.31E+00
4.27E+00 4.31E+00
4.27E+00 4.31E+00
4.27E+00 4.31E+00
4.27E+00 4.30E+00
4.27E+00 4.31E+00
4.26E+00 4.31E+00
4.27E+00 4.32E+00
4.26E+00 4.31E+00
4.26E+00 4.31E+00
4.27E+00 4.27E+00
4.26E+00 4.27E+00
4.26E+00
3.63E-03
4.27E+00
4.25E+00
4.26E+00
4.04E-03
4.27E+00
4.25E+00
4.27E+00
3.13E-03
4.28E+00
4.26E+00
4.26E+00
4.95E-03
4.28E+00
4.25E+00
4.00E+00
PASS
4.26E+00
4.44E-03
4.27E+00
4.24E+00
4.00E+00
PASS
4.27E+00
5.18E-03
4.28E+00
4.25E+00
4.00E+00
PASS
An ISO 9001:2008 and DLA Certified Company
78
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage High 5V Open 2 (V)
@ +VS=+5V, -VS=0V, VCM=0V, No Load
4.35E+00
4.30E+00
4.25E+00
4.20E+00
4.15E+00
4.10E+00
4.05E+00
4.00E+00
3.95E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.36. Plot of Positive Output Voltage High 5V Open 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
79
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.36. Raw data for Positive Output Voltage High 5V Open 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, No
Load versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage High 5V Open 2 (V)
@ +VS=+5V, -VS=0V, VCM=0V, No Load
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.31E+00
4.32E+00
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.25E+00
4.25E+00
24-hr
Anneal
250
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.31E+00
4.31E+00
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.25E+00
4.25E+00
168-hr
Anneal
300
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.31E+00
4.32E+00
4.31E+00
4.32E+00
4.31E+00
4.31E+00
4.26E+00
4.25E+00
4.30E+00
1.03E-02
4.33E+00
4.27E+00
4.31E+00
3.70E-03
4.32E+00
4.30E+00
4.31E+00
2.86E-03
4.32E+00
4.30E+00
4.31E+00
3.71E-03
4.32E+00
4.30E+00
4.29E+00
1.04E-02
4.32E+00
4.26E+00
4.00E+00
PASS
4.31E+00
4.15E-03
4.32E+00
4.30E+00
4.00E+00
PASS
4.31E+00
4.15E-03
4.32E+00
4.30E+00
4.00E+00
PASS
4.31E+00
4.28E-03
4.33E+00
4.30E+00
4.00E+00
PASS
0
4.25E+00
4.26E+00
4.25E+00
4.25E+00
4.25E+00
4.26E+00
4.25E+00
4.26E+00
4.25E+00
4.25E+00
4.26E+00
4.25E+00
Total
20
4.25E+00
4.26E+00
4.25E+00
4.25E+00
4.25E+00
4.25E+00
4.25E+00
4.25E+00
4.24E+00
4.24E+00
4.25E+00
4.25E+00
Dose (krad(Si))
50
100
4.26E+00 4.32E+00
4.26E+00 4.30E+00
4.26E+00 4.30E+00
4.26E+00 4.29E+00
4.25E+00 4.29E+00
4.26E+00 4.30E+00
4.25E+00 4.29E+00
4.26E+00 4.31E+00
4.25E+00 4.29E+00
4.25E+00 4.28E+00
4.26E+00 4.26E+00
4.25E+00 4.25E+00
4.25E+00
3.77E-03
4.26E+00
4.24E+00
4.25E+00
4.62E-03
4.26E+00
4.24E+00
4.26E+00
3.39E-03
4.27E+00
4.25E+00
4.25E+00
4.49E-03
4.27E+00
4.24E+00
4.00E+00
PASS
4.25E+00
4.09E-03
4.26E+00
4.23E+00
4.00E+00
PASS
4.26E+00
5.03E-03
4.27E+00
4.24E+00
4.00E+00
PASS
An ISO 9001:2008 and DLA Certified Company
80
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage High 5V 600 1 (V)
@ +VS=+5V, -VS=0V, VCM=0V, RL=600 Ω
4.50E+00
4.00E+00
3.50E+00
3.00E+00
2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.37. Plot of Positive Output Voltage High 5V 600 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
81
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.37. Raw data for Positive Output Voltage High 5V 600 1 (V) @ +VS=+5V, -VS=0V, VCM=0V,
RL=600Ω versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage High 5V 600 1 (V)
@ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
3.79E+00
3.81E+00
3.79E+00
3.79E+00
3.77E+00
3.80E+00
3.78E+00
3.81E+00
3.78E+00
3.78E+00
3.83E+00
3.83E+00
24-hr
Anneal
250
3.80E+00
3.81E+00
3.79E+00
3.80E+00
3.78E+00
3.80E+00
3.79E+00
3.81E+00
3.78E+00
3.78E+00
3.83E+00
3.83E+00
168-hr
Anneal
300
3.81E+00
3.82E+00
3.80E+00
3.81E+00
3.79E+00
3.81E+00
3.80E+00
3.82E+00
3.79E+00
3.79E+00
3.83E+00
3.83E+00
3.80E+00
9.97E-03
3.83E+00
3.78E+00
3.79E+00
1.17E-02
3.82E+00
3.76E+00
3.79E+00
1.09E-02
3.82E+00
3.76E+00
3.80E+00
1.02E-02
3.83E+00
3.78E+00
3.80E+00
1.17E-02
3.84E+00
3.77E+00
2.80E+00
PASS
3.79E+00
1.41E-02
3.83E+00
3.75E+00
2.80E+00
PASS
3.79E+00
1.42E-02
3.83E+00
3.75E+00
2.80E+00
PASS
3.80E+00
1.29E-02
3.84E+00
3.77E+00
2.80E+00
PASS
0
3.82E+00
3.83E+00
3.82E+00
3.82E+00
3.81E+00
3.82E+00
3.81E+00
3.84E+00
3.81E+00
3.81E+00
3.83E+00
3.83E+00
Total
20
3.82E+00
3.83E+00
3.81E+00
3.82E+00
3.80E+00
3.82E+00
3.81E+00
3.83E+00
3.81E+00
3.81E+00
3.83E+00
3.83E+00
Dose (krad(Si))
50
100
3.81E+00 3.81E+00
3.82E+00 3.82E+00
3.81E+00 3.80E+00
3.81E+00 3.81E+00
3.80E+00 3.79E+00
3.81E+00 3.81E+00
3.80E+00 3.80E+00
3.83E+00 3.82E+00
3.80E+00 3.79E+00
3.80E+00 3.80E+00
3.83E+00 3.83E+00
3.83E+00 3.83E+00
3.82E+00
7.33E-03
3.84E+00
3.80E+00
3.81E+00
9.07E-03
3.84E+00
3.79E+00
3.81E+00
8.76E-03
3.83E+00
3.79E+00
3.82E+00
1.00E-02
3.85E+00
3.79E+00
3.40E+00
PASS
3.81E+00
9.96E-03
3.84E+00
3.79E+00
3.20E+00
PASS
3.81E+00
1.08E-02
3.84E+00
3.78E+00
3.00E+00
PASS
An ISO 9001:2008 and DLA Certified Company
82
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage High 5V 600 2 (V)
@ +VS=+5V, -VS=0V, VCM=0V, RL=600 Ω
4.50E+00
4.00E+00
3.50E+00
3.00E+00
2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.38. Plot of Positive Output Voltage High 5V 600 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
83
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.38. Raw data for Positive Output Voltage High 5V 600 2 (V) @ +VS=+5V, -VS=0V, VCM=0V,
RL=600Ω versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Positive Output Voltage High 5V 600 2 (V)
@ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
200
3.80E+00
3.82E+00
3.80E+00
3.80E+00
3.78E+00
3.81E+00
3.79E+00
3.82E+00
3.79E+00
3.79E+00
3.84E+00
3.83E+00
24-hr
Anneal
250
3.80E+00
3.82E+00
3.80E+00
3.81E+00
3.79E+00
3.81E+00
3.79E+00
3.82E+00
3.79E+00
3.79E+00
3.84E+00
3.83E+00
168-hr
Anneal
300
3.81E+00
3.83E+00
3.81E+00
3.82E+00
3.80E+00
3.82E+00
3.80E+00
3.83E+00
3.80E+00
3.81E+00
3.84E+00
3.83E+00
3.81E+00
9.75E-03
3.84E+00
3.79E+00
3.80E+00
1.18E-02
3.83E+00
3.77E+00
3.80E+00
1.11E-02
3.83E+00
3.77E+00
3.81E+00
1.04E-02
3.84E+00
3.78E+00
3.81E+00
1.07E-02
3.84E+00
3.78E+00
2.80E+00
PASS
3.80E+00
1.33E-02
3.84E+00
3.76E+00
2.80E+00
PASS
3.80E+00
1.29E-02
3.84E+00
3.77E+00
2.80E+00
PASS
3.81E+00
1.20E-02
3.84E+00
3.78E+00
2.80E+00
PASS
0
3.83E+00
3.84E+00
3.83E+00
3.83E+00
3.82E+00
3.83E+00
3.82E+00
3.84E+00
3.82E+00
3.82E+00
3.84E+00
3.83E+00
Total
20
3.82E+00
3.83E+00
3.82E+00
3.82E+00
3.81E+00
3.83E+00
3.82E+00
3.84E+00
3.82E+00
3.82E+00
3.84E+00
3.83E+00
Dose (krad(Si))
50
100
3.82E+00 3.82E+00
3.83E+00 3.83E+00
3.82E+00 3.81E+00
3.82E+00 3.81E+00
3.81E+00 3.80E+00
3.82E+00 3.82E+00
3.81E+00 3.81E+00
3.84E+00 3.83E+00
3.81E+00 3.80E+00
3.81E+00 3.81E+00
3.84E+00 3.84E+00
3.83E+00 3.83E+00
3.83E+00
7.53E-03
3.85E+00
3.81E+00
3.82E+00
9.28E-03
3.85E+00
3.80E+00
3.82E+00
8.62E-03
3.84E+00
3.80E+00
3.83E+00
9.12E-03
3.85E+00
3.80E+00
3.40E+00
PASS
3.82E+00
9.18E-03
3.85E+00
3.80E+00
3.20E+00
PASS
3.82E+00
1.01E-02
3.85E+00
3.79E+00
3.00E+00
PASS
An ISO 9001:2008 and DLA Certified Company
84
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage Low 5V Open 1 (V)
@ +VS=+5V, -VS=0V, VCM=0V, No Load
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.39. Plot of Negative Output Voltage Low 5V Open 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
85
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.39. Raw data for Negative Output Voltage Low 5V Open 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, No
Load versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Output Voltage Low 5V Open 1 (V)
@ +VS=+5V, -VS=0V, VCM=0V, No Load
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
200
1.59E-02
1.52E-02
1.55E-02
1.53E-02
1.54E-02
1.64E-02
1.66E-02
1.63E-02
1.66E-02
1.65E-02
1.38E-02
1.38E-02
24-hr
Anneal
250
1.56E-02
1.51E-02
1.52E-02
1.50E-02
1.51E-02
1.63E-02
1.63E-02
1.62E-02
1.65E-02
1.65E-02
1.39E-02
1.38E-02
168-hr
Anneal
300
1.50E-02
1.49E-02
1.50E-02
1.50E-02
1.50E-02
1.58E-02
1.60E-02
1.56E-02
1.60E-02
1.58E-02
1.39E-02
1.38E-02
1.45E-02
7.07E-05
1.47E-02
1.43E-02
1.55E-02
2.70E-04
1.62E-02
1.47E-02
1.52E-02
2.35E-04
1.58E-02
1.46E-02
1.50E-02
4.47E-05
1.51E-02
1.49E-02
1.48E-02
5.48E-05
1.49E-02
1.46E-02
5.00E-02
PASS
1.65E-02
1.30E-04
1.68E-02
1.61E-02
5.00E-02
PASS
1.64E-02
1.34E-04
1.67E-02
1.60E-02
5.00E-02
PASS
1.58E-02
1.67E-04
1.63E-02
1.54E-02
5.00E-02
PASS
0
1.36E-02
1.39E-02
1.36E-02
1.36E-02
1.35E-02
1.37E-02
1.35E-02
1.39E-02
1.38E-02
1.36E-02
1.39E-02
1.38E-02
Total
20
1.37E-02
1.41E-02
1.38E-02
1.39E-02
1.38E-02
1.39E-02
1.39E-02
1.40E-02
1.38E-02
1.38E-02
1.39E-02
1.38E-02
Dose (krad(Si))
50
100
1.40E-02 1.46E-02
1.42E-02 1.45E-02
1.41E-02 1.45E-02
1.41E-02 1.45E-02
1.39E-02 1.44E-02
1.41E-02 1.48E-02
1.42E-02 1.47E-02
1.43E-02 1.48E-02
1.41E-02 1.48E-02
1.42E-02 1.47E-02
1.38E-02 1.39E-02
1.38E-02 1.38E-02
1.36E-02
1.52E-04
1.41E-02
1.32E-02
1.39E-02
1.52E-04
1.43E-02
1.34E-02
1.41E-02
1.14E-04
1.44E-02
1.37E-02
1.37E-02
1.58E-04
1.41E-02
1.33E-02
2.50E-02
PASS
1.39E-02
8.37E-05
1.41E-02
1.37E-02
3.00E-02
PASS
1.42E-02
8.37E-05
1.44E-02
1.40E-02
4.00E-02
PASS
An ISO 9001:2008 and DLA Certified Company
86
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage Low 5V Open 2 (V)
@ +VS=+5V, -VS=0V, VCM=0V, No Load
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.40. Plot of Negative Output Voltage Low 5V Open 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
87
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.40. Raw data for Negative Output Voltage Low 5V Open 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, No
Load versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Output Voltage Low 5V Open 2 (V)
@ +VS=+5V, -VS=0V, VCM=0V, No Load
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
200
1.58E-02
1.50E-02
1.51E-02
1.51E-02
1.51E-02
1.63E-02
1.64E-02
1.63E-02
1.65E-02
1.63E-02
1.37E-02
1.38E-02
24-hr
Anneal
250
1.53E-02
1.50E-02
1.52E-02
1.50E-02
1.51E-02
1.62E-02
1.63E-02
1.62E-02
1.64E-02
1.62E-02
1.38E-02
1.38E-02
168-hr
Anneal
300
1.49E-02
1.47E-02
1.49E-02
1.50E-02
1.50E-02
1.57E-02
1.57E-02
1.57E-02
1.59E-02
1.57E-02
1.37E-02
1.36E-02
1.43E-02
8.94E-05
1.46E-02
1.41E-02
1.52E-02
3.27E-04
1.61E-02
1.43E-02
1.51E-02
1.30E-04
1.55E-02
1.48E-02
1.49E-02
1.22E-04
1.52E-02
1.46E-02
1.47E-02
1.00E-04
1.50E-02
1.44E-02
5.00E-02
PASS
1.64E-02
8.94E-05
1.66E-02
1.61E-02
5.00E-02
PASS
1.63E-02
8.94E-05
1.65E-02
1.60E-02
5.00E-02
PASS
1.57E-02
8.94E-05
1.60E-02
1.55E-02
5.00E-02
PASS
0
1.36E-02
1.38E-02
1.35E-02
1.37E-02
1.35E-02
1.36E-02
1.34E-02
1.39E-02
1.35E-02
1.35E-02
1.37E-02
1.37E-02
Total
20
1.38E-02
1.41E-02
1.38E-02
1.36E-02
1.36E-02
1.39E-02
1.38E-02
1.41E-02
1.38E-02
1.37E-02
1.37E-02
1.36E-02
Dose (krad(Si))
50
100
1.39E-02 1.44E-02
1.40E-02 1.44E-02
1.40E-02 1.43E-02
1.41E-02 1.44E-02
1.39E-02 1.42E-02
1.41E-02 1.46E-02
1.40E-02 1.46E-02
1.42E-02 1.48E-02
1.40E-02 1.48E-02
1.41E-02 1.47E-02
1.37E-02 1.38E-02
1.37E-02 1.38E-02
1.36E-02
1.30E-04
1.40E-02
1.33E-02
1.38E-02
2.05E-04
1.43E-02
1.32E-02
1.40E-02
8.37E-05
1.42E-02
1.38E-02
1.36E-02
1.92E-04
1.41E-02
1.31E-02
2.50E-02
PASS
1.39E-02
1.52E-04
1.43E-02
1.34E-02
3.00E-02
PASS
1.41E-02
8.37E-05
1.43E-02
1.39E-02
4.00E-02
PASS
An ISO 9001:2008 and DLA Certified Company
88
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage Low 5V 600 1 (V)
@ +VS=+5V, -VS=0V, VCM=0V, RL=600 Ω
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.41. Plot of Negative Output Voltage Low 5V 600 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
89
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.41. Raw data for Negative Output Voltage Low 5V 600 1 (V) @ +VS=+5V, -VS=0V, VCM=0V,
RL=600Ω versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Output Voltage Low 5V 600 1 (V)
@ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
200
5.50E-03
5.40E-03
5.30E-03
5.50E-03
5.40E-03
5.60E-03
5.70E-03
5.50E-03
5.70E-03
5.60E-03
6.50E-03
6.40E-03
24-hr
Anneal
250
5.40E-03
5.30E-03
5.40E-03
5.40E-03
5.30E-03
5.40E-03
5.40E-03
5.30E-03
5.50E-03
5.40E-03
6.40E-03
6.40E-03
168-hr
Anneal
300
5.30E-03
5.50E-03
5.30E-03
5.50E-03
5.40E-03
5.40E-03
5.20E-03
5.30E-03
5.40E-03
5.40E-03
6.30E-03
6.30E-03
5.92E-03
8.37E-05
6.15E-03
5.69E-03
5.42E-03
8.37E-05
5.65E-03
5.19E-03
5.36E-03
5.48E-05
5.51E-03
5.21E-03
5.40E-03
1.00E-04
5.67E-03
5.13E-03
6.02E-03
4.47E-05
6.14E-03
5.90E-03
1.00E-02
PASS
5.62E-03
8.37E-05
5.85E-03
5.39E-03
1.00E-02
PASS
5.40E-03
7.07E-05
5.59E-03
5.21E-03
1.00E-02
PASS
5.34E-03
8.94E-05
5.59E-03
5.09E-03
1.00E-02
PASS
0
6.30E-03
6.30E-03
6.10E-03
6.10E-03
6.30E-03
6.20E-03
6.20E-03
6.20E-03
6.10E-03
6.20E-03
6.30E-03
6.30E-03
Total
20
6.20E-03
6.40E-03
6.20E-03
6.20E-03
6.20E-03
6.30E-03
6.40E-03
6.40E-03
6.40E-03
6.30E-03
6.40E-03
6.30E-03
Dose (krad(Si))
50
100
6.10E-03 5.90E-03
6.30E-03 6.00E-03
6.20E-03 6.00E-03
6.30E-03 5.80E-03
6.30E-03 5.90E-03
6.40E-03 6.00E-03
6.30E-03 6.00E-03
6.40E-03 6.10E-03
6.20E-03 6.00E-03
6.20E-03 6.00E-03
6.30E-03 6.30E-03
6.60E-03 6.50E-03
6.22E-03
1.10E-04
6.52E-03
5.92E-03
6.24E-03
8.94E-05
6.49E-03
5.99E-03
6.24E-03
8.94E-05
6.49E-03
5.99E-03
6.18E-03
4.47E-05
6.30E-03
6.06E-03
1.00E-02
PASS
6.36E-03
5.48E-05
6.51E-03
6.21E-03
1.00E-02
PASS
6.30E-03
1.00E-04
6.57E-03
6.03E-03
1.00E-02
PASS
An ISO 9001:2008 and DLA Certified Company
90
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage Low 5V 600 2 (V)
@ +VS=+5V, -VS=0V, VCM=0V, RL=600 Ω
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.42. Plot of Negative Output Voltage Low 5V 600 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under
electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated
with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower confidence limits, as
determined by KTL statistics, on the samples irradiated under electrical bias while the gray lines (solid and/or
dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the samples irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum
specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
91
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.42. Raw data for Negative Output Voltage Low 5V 600 2 (V) @ +VS=+5V, -VS=0V, VCM=0V,
RL=600Ω versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Negative Output Voltage Low 5V 600 2 (V)
@ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
200
5.70E-03
5.70E-03
5.50E-03
5.60E-03
5.60E-03
5.80E-03
5.80E-03
5.80E-03
5.90E-03
5.80E-03
6.70E-03
6.60E-03
24-hr
Anneal
250
5.50E-03
5.50E-03
5.40E-03
5.60E-03
5.50E-03
5.60E-03
5.70E-03
5.60E-03
5.70E-03
5.80E-03
6.60E-03
6.50E-03
168-hr
Anneal
300
5.50E-03
5.60E-03
5.50E-03
5.50E-03
5.60E-03
5.40E-03
5.40E-03
5.40E-03
5.70E-03
5.70E-03
6.50E-03
6.50E-03
6.16E-03
1.14E-04
6.47E-03
5.85E-03
5.62E-03
8.37E-05
5.85E-03
5.39E-03
5.50E-03
7.07E-05
5.69E-03
5.31E-03
5.54E-03
5.48E-05
5.69E-03
5.39E-03
6.28E-03
8.37E-05
6.51E-03
6.05E-03
1.00E-02
PASS
5.82E-03
4.47E-05
5.94E-03
5.70E-03
1.00E-02
PASS
5.68E-03
8.37E-05
5.91E-03
5.45E-03
1.00E-02
PASS
5.52E-03
1.64E-04
5.97E-03
5.07E-03
1.00E-02
PASS
0
6.30E-03
6.50E-03
6.40E-03
6.40E-03
6.30E-03
6.30E-03
6.30E-03
6.40E-03
6.30E-03
6.40E-03
6.50E-03
6.50E-03
Total
20
6.50E-03
6.60E-03
6.40E-03
6.50E-03
6.40E-03
6.60E-03
6.50E-03
6.60E-03
6.60E-03
6.60E-03
6.70E-03
6.70E-03
Dose (krad(Si))
50
100
6.50E-03 6.10E-03
6.60E-03 6.30E-03
6.40E-03 6.00E-03
6.50E-03 6.20E-03
6.40E-03 6.20E-03
6.50E-03 6.20E-03
6.50E-03 6.20E-03
6.60E-03 6.40E-03
6.50E-03 6.30E-03
6.50E-03 6.30E-03
6.60E-03 6.60E-03
6.60E-03 6.60E-03
6.38E-03
8.37E-05
6.61E-03
6.15E-03
6.48E-03
8.37E-05
6.71E-03
6.25E-03
6.48E-03
8.37E-05
6.71E-03
6.25E-03
6.34E-03
5.48E-05
6.49E-03
6.19E-03
1.00E-02
PASS
6.58E-03
4.47E-05
6.70E-03
6.46E-03
1.00E-02
PASS
6.52E-03
4.47E-05
6.64E-03
6.40E-03
1.00E-02
PASS
An ISO 9001:2008 and DLA Certified Company
92
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage Low 5V 1mA 1 (V)
@ +VS=+5V, -VS=0V, VCM=0V, ISINK=1mA
2.00E+00
1.80E+00
1.60E+00
1.40E+00
1.20E+00
1.00E+00
8.00E-01
6.00E-01
4.00E-01
2.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.43. Plot of Negative Output Voltage Low 5V 1mA 1 (V) @ +VS=+5V, -VS=0V, VCM=0V,
ISINK=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples
irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the
samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower
confidence limits, as determined by KTL statistics, on the samples irradiated under electrical bias while the gray
lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the
samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum
and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
93
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.43. Raw data for Negative Output Voltage Low 5V 1mA 1 (V) @ +VS=+5V, -VS=0V, VCM=0V,
ISINK=1mA versus total dose, including the statistical analysis, specification and the status of the testing
(pass/fail).
Negative Output Voltage Low 5V 1mA 1 (V)
@ +VS=+5V, -VS=0V, VCM=0V, ISINK=1mA
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
200
3.22E-01
3.07E-01
1.03E+00
3.01E-01
3.17E-01
3.32E-01
3.10E-01
1.04E+00
3.33E-01
3.04E-01
2.39E-01
2.40E-01
24-hr
Anneal
250
9.97E-01
3.29E-01
1.03E+00
3.15E-01
3.38E-01
1.13E+00
1.07E+00
1.19E+00
1.11E+00
1.03E+00
2.40E-01
2.41E-01
168-hr
Anneal
300
1.01E+00
3.01E-01
1.01E+00
3.15E-01
9.32E-01
1.15E+00
1.14E+00
1.19E+00
1.12E+00
1.12E+00
2.39E-01
2.39E-01
2.54E-01
1.95E-03
2.60E-01
2.49E-01
4.55E-01
3.20E-01
1.33E+00
-4.22E-01
6.03E-01
3.77E-01
1.64E+00
-4.32E-01
7.14E-01
3.72E-01
1.73E+00
-3.06E-01
2.53E-01
1.14E-03
2.56E-01
2.49E-01
1.60E+00
PASS
4.63E-01
3.21E-01
1.34E+00
-4.16E-01
1.60E+00
PASS
1.10E+00
6.23E-02
1.27E+00
9.33E-01
1.60E+00
PASS
1.15E+00
2.86E-02
1.22E+00
1.07E+00
1.60E+00
PASS
0
2.41E-01
2.40E-01
2.42E-01
2.41E-01
2.40E-01
2.41E-01
2.41E-01
2.38E-01
2.40E-01
2.41E-01
2.39E-01
2.40E-01
Total
20
2.41E-01
2.41E-01
2.42E-01
2.41E-01
2.40E-01
2.40E-01
2.39E-01
2.37E-01
2.41E-01
2.39E-01
2.39E-01
2.41E-01
Dose (krad(Si))
50
100
2.44E-01 2.57E-01
2.42E-01 2.53E-01
2.44E-01 2.56E-01
2.44E-01 2.53E-01
2.43E-01 2.53E-01
2.43E-01 2.53E-01
2.42E-01 2.52E-01
2.41E-01 2.51E-01
2.44E-01 2.54E-01
2.43E-01 2.53E-01
2.39E-01 2.39E-01
2.40E-01 2.40E-01
2.41E-01
8.37E-04
2.43E-01
2.39E-01
2.41E-01
7.07E-04
2.43E-01
2.39E-01
2.43E-01
8.94E-04
2.46E-01
2.41E-01
2.40E-01
1.30E-03
2.44E-01
2.37E-01
3.50E-01
PASS
2.39E-01
1.48E-03
2.43E-01
2.35E-01
8.00E-01
PASS
2.43E-01
1.14E-03
2.46E-01
2.39E-01
1.00E+00
PASS
An ISO 9001:2008 and DLA Certified Company
94
TID Report
14-0247 06/13/14 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage Low 5V 1mA 2 (V)
@ +VS=+5V, -VS=0V, VCM=0V, ISINK=1mA
1.80E+00
1.60E+00
1.40E+00
1.20E+00
1.00E+00
8.00E-01
6.00E-01
4.00E-01
2.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
24-hr
250
Anneal
168-hr
300
Anneal
Figure 5.44. Plot of Negative Output Voltage Low 5V 1mA 2 (V) @ +VS=+5V, -VS=0V, VCM=0V,
ISINK=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples
irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the
samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the upper and/or lower
confidence limits, as determined by KTL statistics, on the samples irradiated under electrical bias while the gray
lines (solid and/or dashed) are the upper and/or lower confidence limits, as determined by KTL statistics, on the
samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum
and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DLA Certified Company
95
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table 5.44. Raw data for Negative Output Voltage Low 5V 1mA 2 (V) @ +VS=+5V, -VS=0V, VCM=0V,
ISINK=1mA versus total dose, including the statistical analysis, specification and the status of the testing
(pass/fail).
Negative Output Voltage Low 5V 1mA 2 (V)
@ +VS=+5V, -VS=0V, VCM=0V, ISINK=1mA
Device
27
28
29
30
31
32
33
34
35
36
37
38
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
200
2.88E-01
2.82E-01
2.92E-01
2.80E-01
2.84E-01
2.87E-01
2.85E-01
2.96E-01
2.92E-01
2.80E-01
2.34E-01
2.35E-01
24-hr
Anneal
250
2.96E-01
2.87E-01
2.99E-01
2.86E-01
2.89E-01
3.16E-01
3.08E-01
3.29E-01
3.30E-01
2.97E-01
2.36E-01
2.37E-01
168-hr
Anneal
300
2.97E-01
2.77E-01
2.93E-01
2.84E-01
2.91E-01
9.72E-01
9.90E-01
9.81E-01
9.62E-01
3.34E-01
2.34E-01
2.34E-01
2.48E-01
1.41E-03
2.52E-01
2.44E-01
2.85E-01
4.82E-03
2.98E-01
2.72E-01
2.91E-01
5.77E-03
3.07E-01
2.76E-01
2.88E-01
7.92E-03
3.10E-01
2.67E-01
2.47E-01
1.14E-03
2.50E-01
2.43E-01
1.60E+00
PASS
2.88E-01
6.20E-03
3.05E-01
2.71E-01
1.60E+00
PASS
3.16E-01
1.41E-02
3.55E-01
2.77E-01
1.60E+00
PASS
8.48E-01
2.87E-01
1.64E+00
5.97E-02
1.60E+00
PASS
0
2.36E-01
2.35E-01
2.36E-01
2.36E-01
2.35E-01
2.36E-01
2.36E-01
2.34E-01
2.36E-01
2.35E-01
2.35E-01
2.35E-01
Total
20
2.37E-01
2.36E-01
2.37E-01
2.36E-01
2.36E-01
2.35E-01
2.35E-01
2.33E-01
2.36E-01
2.34E-01
2.35E-01
2.36E-01
Dose (krad(Si))
50
100
2.38E-01 2.50E-01
2.37E-01 2.47E-01
2.40E-01 2.49E-01
2.39E-01 2.47E-01
2.38E-01 2.47E-01
2.38E-01 2.47E-01
2.39E-01 2.47E-01
2.36E-01 2.45E-01
2.39E-01 2.48E-01
2.37E-01 2.46E-01
2.35E-01 2.34E-01
2.35E-01 2.35E-01
2.36E-01
5.48E-04
2.37E-01
2.34E-01
2.36E-01
5.48E-04
2.38E-01
2.35E-01
2.38E-01
1.14E-03
2.42E-01
2.35E-01
2.35E-01
8.94E-04
2.38E-01
2.33E-01
3.50E-01
PASS
2.35E-01
1.14E-03
2.38E-01
2.31E-01
8.00E-01
PASS
2.38E-01
1.30E-03
2.41E-01
2.34E-01
1.00E+00
PASS
An ISO 9001:2008 and DLA Certified Company
96
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
6.0. Summary / Conclusions
The total ionizing dose testing described in this final report was performed using the facilities at
Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose
(TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are
held in the base of the irradiator heavily shielded by lead, during the radiation exposures the rod is raised
by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in
this configuration ranges from <1rad(Si)/s to a maximum of approximately 300rad(Si)/s, determined by
the distance from the source.
The parametric data was obtained as "read and record" and all the raw data plus an attributes summary
are contained in this report as well as in a separate Excel file. The attributes data contains the average,
standard deviation and the average with the KTL values applied. The KTL value used in this work is
2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The
90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535
sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the
following criteria must be met for a device to pass the total ionizing dose test: following the radiation
exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units
irradiated without electrical bias and the KTL statistics are included in this report for reference only. If
any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet
specification limits, then the lot could be logged as a failure.
Based on this criterion the RH1013MH Dual Precision Operational Amplifier (from the lot traceability
information provided on the first page of this test report) the units-under-test:
 PASSED the total ionizing dose test to the 200krad(Si) dose level
 PASSED following 24-hour room temperature anneal
 PASSED following 168-hour 100°C anneal
An ISO 9001:2008 and DLA Certified Company
97
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Appendix A: Photograph of Packing Label and a Sample Unit-Under-Test to Show Part
Traceability
An ISO 9001:2008 and DLA Certified Company
98
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Appendix B: Radiation Bias Connections and Absolute Maximum Ratings
TID Radiation Biased Conditions: Extracted from Linear Technology RH1013M Datasheet
Revision E.
Pin Function
Connection / Bias
1
OUT A
To Pin 2 via 10kΩ Resistor
2
-IN A
To Pin 1 via 10kΩ Resistor
3
+IN A
8V via 10kΩ Resistor
4
V- (Case) -15V Decoupled to GND W/0.1µF
5
+IN B
8V via 10kΩ Resistor
6
-IN B
To Pin 7 via 10kΩ Resistor
7
OUT B
To Pin 6 via 10kΩ Resistor
8
V+
+15V Decoupled to GND W/0.1µF
Figure B.1. Irradiation bias circuit. This figure was extracted from Linear Technology RH1013M Datasheet
Revision E.
An ISO 9001:2008 and DLA Certified Company
99
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
TID Radiation Unbiased Conditions: All pins grounded.
Pin Function Connection / Bias
1
OUT A
GND
2
-IN A
GND
3
+IN A
GND
4
V- (Case) GND
5
+IN B
GND
6
-IN B
GND
7
OUT B
GND
8
V+
GND
Figure B.2. H package drawing (for reference only). This figure was extracted from Linear Technology
RH1013M Datasheet Revision E.
Absolute Maximum Ratings:
Parameter
Supply Voltage
Max Rating
±22V
Differential Voltage
±30V
Equal to Positive Supply Voltage
Input Voltage
5V Below Negative Supply Voltage
Output Short-Circuit Duration Indefinite
An ISO 9001:2008 and DLA Certified Company
100
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Appendix C: Electrical Test Parameters and Conditions
The expected ranges of values as well as the measurement conditions are taken from Linear Technology
RH1013M Datasheet Revision E. All electrical tests for this device are performed on one of Aeroflex
RAD's LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that
provides parameter measurements for a variety of digital, analog and mixed signal products including
voltage regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System
achieves accuracy and sensitivity through the use of software self-calibration and an internal relay
matrix with separate family boards and custom personality adapter boards. The tester uses this relay
matrix to connect the required test circuits, select the appropriate voltage / current sources and establish
the needed measurement loops for all the tests performed. The measured parameters and test conditions
are shown in Table C.1.
A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The
precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020
for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table
C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between
tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90
KTL statistics were applied to the measured standard deviation to generate the final measurement range.
This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020
mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the
measurement resolution is limited by the internal DACs, which results in a measured standard deviation
of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC.
Note that the testing and statistics used in this document are based on an “analysis of variables”
technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p.
91 for a discussion of statistical treatments). Not all measured parameters are well suited to this
approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify
these parameters using an “attributes” approach.
An ISO 9001:2008 and DLA Certified Company
101
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table C.1. Measured parameters and test conditions for the RH1013MH Dual Precision Operational Amplifier.
Parameter
Symbol
Test Conditions
Positive Supply Current 15V (A)
+ICC_15V
VS=+/-15V, VCM=0V
Negative Supply Current 15V (A)
-IEE_15V
VS=+/-15V, VCM=0V
Input Offset Voltage 15V (V)
VOS_15V
VS=+/-15V, VCM=0V
Input Offset Current 15V (A)
IOS_15V
VS=+/-15V, VCM=0V
Positive Input Bias Current 15V (A)
+IB_15V
VS=+/-15V, VCM=0V
Negative Input Bias Current 15V (A)
-IB_15V
VS=+/-15V, VCM=0V
Common Mode Rejection Ratio 15V (dB)
CMRR_15V
VCM=+13V, -15V
Power Supply Rejection Ratio 15V (dB)
PSRR_15V
VS=+/-10V to +/-18V
Large-Signal Voltage Gain 15V (V/mV)
AVOL_15V
RL=10K, VO=+/-10V
Positive Output Voltage Swing 15V (V)
+VOUT_15V
VS=+/-15V, VCM=0V, RL=10k
Negative Output Voltage Swing 15V (V)
-VOUT_15V
VS=+/-15V, VCM=0V, RL=10k
Positive Slew Rate 15V (V/µs)
+SlewRate_15V
AV=1, VS=+/-15V, VCM=0V
Negative Slew Rate 15V (V/µs)
-SlewRate_15V
AV=1, VS=+/-15V, VCM=0V
Positive Supply Current 5V (A)
+ICC_5V
+VS=5V, -VS=0V, VCM=0V, VOUT=4V
Negative Supply Current 5V (A)
-IEE_5V
+VS=5V, -VS=0V, VCM=0V, VOUT=4V
Input Offset Voltage 5V (V)
VOS_5V
+VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Input Offset Current 5V (A)
IOS_5V
+VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Positive Input Bias Current 5V (A)
+IB_5V
+VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Negative Input Bias Current 5V (A)
-IB_5V
+VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Positive Output Voltage High 5V Open (V)
+VOUT_5V Open +VS=+5V, -VS=0V, VCM=0V, No Load
Positive Output Voltage High 5V 600 (V)
+VOUT_5V 600
+VS=+5V, -VS=0V, VCM=0V, RL=600Ω
Negative Output Voltage Low 5V Open (V)
-VOUT_5V Open
+VS=+5V, -VS=0V, VCM=0V, No Load
Negative Output Voltage Low 5V 600 (V)
-VOUT_5V 600
+VS=+5V, -VS=0V, VCM=0V, RL=600Ω
+VS=+5V, -VS=0V,
VCM=0V, ISINK=1mA
Negative Output Voltage Low 5V 1mA (V) -VOUT_5V 1mA
An ISO 9001:2008 and DLA Certified Company
102
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH1013MH
Dual Precision Operational Amplifier.
Pre-Irradiation
Specification
MIN
MAX
Parameter
Positive Supply Current 15V (A)
1.10E-03
Measurement
Precision/Resolution
±1.75E-06
Negative Supply Current 15V (A)
-1.10E-03
Input Offset Voltage 15V (V)
-3.00E-04
3.00E-04
±2.87E-06
Input Offset Current 15V (A)
-1.00E-08
1.00E-08
±2.73E-11
Positive Input Bias Current 15V (A)
-3.00E-08
3.00E-08
±2.34E-11
Negative Input Bias Current 15V (A)
-3.00E-08
3.00E-08
±3.20E-11
Common Mode Rejection Ratio 15V (dB)
9.70E+01
±6.95E-01
Power Supply Rejection Ratio 15V (dB)
1.00E+02
±4.07E+00
Large-Signal Voltage Gain 15V (V/mV)
1.20E+03
±4.72E+01%
Positive Output Voltage Swing 15V (V)
1.25E+01
±6.53E-04
Negative Output Voltage Swing 15V (V)
Positive Slew Rate 15V (V/µs)
±2.05E-06
-1.25E+01
2.00E-01
Negative Slew Rate 15V (V/µs)
±8.71E-04
±3.02E-02
-2.00E-01
±3.49E-02
Input Offset Voltage 5V (V)
-4.50E-04
4.50E-04
±9.65E-07
Input Offset Current 5V (A)
-1.00E-08
1.00E-08
±2.94E-11
Positive Input Bias Current 5V (A)
-5.00E-08
5.00E-08
±5.94E-11
Positive Input Bias Current 5V (A)
-5.00E-08
5.00E-08
±4.89E-11
Positive Output Voltage High 5V Open (V)
4.00E+00
±8.71E-04
Positive Output Voltage High 5V 600 (V)
3.40E+00
±9.97E-04
Negative Output Voltage Low 5V Open (V)
2.50E-02
±1.74E-04
Negative Output Voltage Low 5V 600 (V)
1.00E-02
±1.70E-04
Negative Output Voltage Low 5V 1mA (V)
3.50E-01
±6.53E-04
An ISO 9001:2008 and DLA Certified Company
103
TID Report
14-0247 06/13/14 R1.0
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Appendix D: List of Figures Used in the Results Section (Section 5)
5.1.
5.2.
5.3.
5.4.
5.5.
5.6.
5.7.
5.8.
5.9.
5.10.
5.11.
5.12.
5.13.
5.14.
5.15.
5.16.
5.17.
5.18.
5.19.
5.20.
5.21.
5.22.
5.23.
5.24.
5.25.
5.26.
5.27.
5.28.
5.29.
5.30.
5.31.
5.32.
5.33.
5.34.
5.35.
5.36.
5.37.
5.38.
5.39.
5.40.
Positive Supply Current 15V (A) @ VS=+/-15V, VCM=0V
Negative Supply Current 15V (A) @ VS=+/-15V, VCM=0V
Input Offset Voltage1 15V (V) @ VS=+/-15V, VCM=0V
Input Offset Voltage2 15V (V) @ VS=+/-15V, VCM=0V
Input Offset Current1 15V (A) @ VS=+/-15V, VCM=0V
Input Offset Current2 15V (A) @ VS=+/-15V, VCM=0V
Positive Input Bias Current1 15V (A) @ VS=+/-15V, VCM=0V
Positive Input Bias Current2 15V (A) @ VS=+/-15V, VCM=0V
Negative Input Bias Current1 15V (A) @ VS=+/-15V, VCM=0V
Negative Input Bias Current2 15V (A) @ VS=+/-15V, VCM=0V
Common Mode Rejection Ratio1 15V (dB) @ VCM=+13V, -15V
Common Mode Rejection Ratio2 15V (dB) @ VCM=+13V, -15V
Power Supply Rejection Ratio1 15V (dB) @ VS=+/-10V to +/-18V
Power Supply Rejection Ratio2 15V (dB) @ VS=+/-10V to +/-18V
Large-Signal Voltage Gain1 15V (V/mV) @ RL=10K, VO=+/-10V
Large-Signal Voltage Gain2 15V (V/mV) @ RL=10K, VO=+/-10V
Positive Output Voltage Swing1 15V (V) @ VS=+/-15V, VCM=0V, RL=10k
Positive Output Voltage Swing2 15V (V) @ VS=+/-15V, VCM=0V, RL=10k
Negative Output Voltage Swing1 15V (V) @ VS=+/-15V, VCM=0V, RL=10k
Negative Output Voltage Swing2 15V (V) @ VS=+/-15V, VCM=0V, RL=10k
Positive Slew Rate1 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V
Positive Slew Rate2 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V
Negative Slew Rate1 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V
Negative Slew Rate2 15V (V/µs) @ AV=1, VS=+/-15V, VCM=0V
Positive Supply Current 5V (A) @ +VS=5V, -VS=0V, VCM=0V, VOUT=4V
Negative Supply Current 5V (A) @ +VS=5V, -VS=0V, VCM=0V, VOUT=4V
Input Offset Voltage1 5V (V) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Input Offset Voltage2 5V (V) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Input Offset Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Input Offset Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Positive Input Bias Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Positive Input Bias Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Negative Input Bias Current1 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Negative Input Bias Current2 5V (A) @ +VS=+5V, -VS=0V, VCM=0V, VOUT=4V
Positive Output Voltage High 5V Open 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
Positive Output Voltage High 5V Open 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
Positive Output Voltage High 5V 600 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
Positive Output Voltage High 5V 600 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
Negative Output Voltage Low 5V Open 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
Negative Output Voltage Low 5V Open 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, No Load
An ISO 9001:2008 and DLA Certified Company
104
TID Report
14-0247 06/13/14 R1.0
5.41.
5.42.
5.43.
5.44.
Aeroflex RAD
5030 Centennial Blvd.
Colorado Springs, CO 80919
(719) 531-0800
Negative Output Voltage Low 5V 600 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
Negative Output Voltage Low 5V 600 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, RL=600Ω
Negative Output Voltage Low 5V 1mA 1 (V) @ +VS=+5V, -VS=0V, VCM=0V, ISINK=1mA
Negative Output Voltage Low 5V 1mA 2 (V) @ +VS=+5V, -VS=0V, VCM=0V, ISINK=1mA
An ISO 9001:2008 and DLA Certified Company
105