ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Enhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH1014MW Quad Precision Operational Amplifier for Linear Technology Customer: Linear Technology, PO# 60735L RAD Job Number: 11-573 Part Type Tested: RH1014MW Quad Precision Operational Amplifier, RH1014M datasheet Traceability Information: Lot Number: 628465.1, Fab Lot Number: W10905043, Wafer Number: 07, Date Code 1122A. See photograph of unit under test in Appendix A. Quantity of Units: 12 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 2 units for control. Serial numbers 1841-1845 were biased during irradiation, serial numbers 1846-1850 were unbiased during irradiation and serial numbers 1851 and 1852 were used as control. Control units will be shared with RAD Job 11-572. See Appendix B for the radiation bias connection table. Radiation and Electrical Test Increments: 10mrad(Si)/s ionizing radiation with electrical test increments: pre-irradiation, 10krad(Si), 20krad(Si), 30krad(Si) and 50krad(Si). Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD. Overtest and Post-Irradiation Anneal: No overtest. 24-hour room temperature anneal followed by a 168-hour 100°C anneal. Both anneals shall be performed in the same electrical bias condition as the irradiations. Electrical measurements shall be made following each anneal increment. Radiation Test Standard: MIL-STD-750E TM1019 and/or MIL-STD-883H TM1019 Condition D. Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS04, Calibration Date: 4/28/2011, Calibration Due: 4/28/2012. LTS2101 Family Board, Entity ID FB10. LTS0600 Test Fixture, Entity ID TF01. BGSS-970312 RH1014 DUT Board. Test Program: RH1014LT.SRC Facility and Radiation Source: Aeroflex RAD's Longmire Laboratories, Colorado Springs, CO. Gamma rays provided by Co60 (GB-150) low dose rate source. Dosimetry performed by Air Ionization Chamber (AIC) traceable to NIST. Aeroflex RAD's dosimetry has been audited by DSCC and Aeroflex RAD has been awarded Laboratory Suitability for MIL-STD-750 and MIL-STD-883 TM 1019. Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and MIL-STD-750. Low Dose Rate Test Result: PASSED the enhanced low dose rate sensitivity test to the maximum tested dose level of 50krad(Si) with all parameters remaining within their datasheet specifications. An ISO 9001:2008 and DSCC Certified Company 1 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 1.0. Overview and Background It is well known that total dose ionizing radiation can cause parametric degradation and ultimately functional failure in electronic devices. The damage occurs via electron-hole pair production, transport and trapping in the dielectric regions. In advanced CMOS technology nodes (0.6µm and smaller) the bulk of the damage is manifested in the thicker isolation regions, such as shallow trench or local oxidation of silicon (LOCOS) oxides (also known as "birds-beak" oxides). However, many linear and mixed signal devices that utilize bipolar minority carrier elements exhibit an enhanced low dose rate sensitivity (ELDRS). At this time there is no known or accepted a priori method for predicting susceptibility to ELDRS or simulating the low dose rate sensitivity with a "conventional" room temperature 50-300rad(Si)/s irradiation (Condition A in MIL-STD-883 TM 1019.8). Over the past 10 years a number of accelerating techniques have been examined, including an elevated temperature anneal, such as that used for MOS devices (see ASTM-F-1892 for more technical details) and irradiating at various temperatures. However, none of these techniques have proven useful across the wide variety of linear and/or mixed signal devices used in spaceborne applications. The latest requirement incorporated in MIL-STD-883 TM 1019 requires that devices that could potentially exhibit ELDRS "shall be tested either at the intended application dose rate, at a prescribed low dose rate to an overtest radiation level, or with an accelerated test such as an elevated temperature irradiation test that includes a parameter delta design margin". While the recently released MIL-STD883 TM 1019 allows for accelerated testing, the requirements for this are to essentially perform a low dose rate ELDRS test to verify the suitability of the acceleration method on the component of interest before the acceleration technique can be instituted. Based on the limitations of accelerated testing and to meet the requirements of MIL-STD-883 TM1019.8 Condition D, we have performed a low dose rate test at 10mrad(Si)/s. 2.0. Radiation Test Apparatus The low dose rate testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The low dose rate source is a GB-150 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead. During the irradiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from approximately 1mrad(Si)/s to a maximum of approximately 50rad(Si)/s, determined by the distance from the source. For low dose rate testing described in this report, the devices are placed approximately 2-meters from the Co-60 rods. The irradiator calibration is maintained by Aeroflex RAD's Longmire Laboratories using air ionization chamber (AIC) dosimetry traceable to the National Institute of Standards and Technology (NIST). Figure 2.1 shows a photograph of the GB-150 Co-60 irradiator at Aeroflex RAD's Longmire Laboratory facility. An ISO 9001:2008 and DSCC Certified Company 2 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Figure 2.1. Aeroflex RAD's Co-60 irradiator. The dose rate is obtained by positioning the device-under-test at a fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately 50rad(Si)/s close to the rods down to <1mrad(Si)/s at a distance of approximately 4-meters. An ISO 9001:2008 and DSCC Certified Company 3 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 3.0. Radiation Test Conditions The RH1014MW Quad Precision Operational Amplifier described in this final report were irradiated using a split 15 supply and with all pins tied to ground, that is biased and unbiased. See Appendix B for details on the biasing conditions during radiation exposure. In our opinion, this bias circuit satisfies the requirements of MIL-STD-883H TM1019.8 Section 3.9.3 Bias and Loading Conditions which states "The bias applied to the test devices shall be selected to produce the greatest radiation induced damage or the worst-case damage for the intended application, if known. While maximum voltage is often worst case some bipolar linear device parameters (e.g. input bias current or maximum output load current) exhibit more degradation with 0 V bias." The devices were irradiated to a maximum total ionizing dose level of 50krad(Si) with incremental readings at 10krad(Si), 20krad(Si) and 30krad(Si). Electrical testing occurred within one hour following the end of each irradiation segment. For intermediate irradiations, the units were tested and returned to total dose exposure within two hours from the end of the previous radiation increment. The radiation exposure bias board was positioned in the Co-60 cell to provide the targeted dose rate of10mrad(Si)/s and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019.8 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1) initially, (2) when the source is changed, or (3) when the orientation or configuration of the source, container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g., a TLD) in the device-irradiation container at the approximate test-device position. If it can be demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors due to dose enhancement, the Pb/Al container may be omitted". The final dose rate within the lead-aluminum box was determined based on air ionization chamber (AIC) dosimetry measurements just prior to the beginning of the total dose irradiations. The final dose rate for this work was 10mrad(Si)/s with a precision of ±5%. An ISO 9001:2008 and DSCC Certified Company 4 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 4.0. Tested Parameters During the enhanced low dose rate sensitivity testing the following electrical parameters were measured pre- and post-irradiation: 1. Positive Supply Current @ +/-15V (A) 2. Negative Supply Current @ +/-15V (A) 3. Offset Voltage 1 @ +/-15V (V) 4. Offset Voltage 2 @ +/-15V (V) 5. Offset Voltage 3 @ +/-15V (V) 6. Offset Voltage 4 @ +/-15V (V) 7. Offset Current 1 @ +/-15V (A) 8. Offset Current 2 @ +/-15V (A) 9. Offset Current 3 @ +/-15V (A) 10. Offset Current 4 @ +/-15V (A) 11. Positive Bias Current 1 @ +/-15V (A) 12. Positive Bias Current 2 @ +/-15V (A) 13. Positive Bias Current 3 @ +/-15V (A) 14. Positive Bias Current 4 @ +/-15V (A) 15. Negative Bias Current 1 @ +/-15V (A) 16. Negative Bias Current 2 @ +/-15V (A) 17. Negative Bias Current 3 @ +/-15V (A) 18. Negative Bias Current 4 @ +/-15V (A) 19. Common Mode Rejection Ratio 1 (dB) 20. Common Mode Rejection Ratio 2 (dB) 21. Common Mode Rejection Ratio 3 (dB) 22. Common Mode Rejection Ratio 4 (dB) 23. Power Supply Rejection Ratio 1 (dB) 24. Power Supply Rejection Ratio 2 (dB) 25. Power Supply Rejection Ratio 3 (dB) 26. Power Supply Rejection Ratio 4 (dB) 27. Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) 28. Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) 29. Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) 30. Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) 31. Positive Output Voltage 1 @ +/-15V (V) 32. Positive Output Voltage 2 @ +/-15V (V) 33. Positive Output Voltage 3 @ +/-15V (V) 34. Positive Output Voltage 4 @ +/-15V (V) 35. Negative Output Voltage 1 @ +/-15V (V) 36. Negative Output Voltage 2 @ +/-15V (V) 37. Negative Output Voltage 3 @ +/-15V (V) An ISO 9001:2008 and DSCC Certified Company 5 ELDRS Report 11-573 R1.0 38. Negative Output Voltage 4 @ +/-15V (V) 39. Positive Slew Rate 1 @ +/-15V (V/us) 40. Positive Slew Rate 2 @ +/-15V (V/us) 41. Positive Slew Rate 3 @ +/-15V (V/us) 42. Positive Slew Rate 4 @ +/-15V (V/us) 43. Negative Slew Rate 1 @ +/-15V (V/us) 44. Negative Slew Rate 2 @ +/-15V (V/us) 45. Negative Slew Rate 3 @ +/-15V (V/us) 46. Negative Slew Rate 4 @ +/-15V (V/us) 47. Positive Supply Current @ +5V (A) 48. Negative Supply Current @ +5V (A) 49. Offset Voltage 1 @ +5V (V) 50. Offset Voltage 2 @ +5V (V) 51. Offset Voltage 3 @ +5V (V) 52. Offset Voltage 4 @ +5V (V) 53. Offset Current 1 @ +5V (A) 54. Offset Current 2 @ +5V (A) 55. Offset Current 3 @ +5V (A) 56. Offset Current 4 @ +5V (A) 57. Positive Bias Current 1 @ +5V (A) 58. Positive Bias Current 2 @ +5V (A) 59. Positive Bias Current 3 @ +5V (A) 60. Positive Bias Current 4 @ +5V (A) 61. Negative Bias Current 1 @ +5V (A) 62. Negative Bias Current 2 @ +5V (A) 63. Negative Bias Current 3 @ +5V (A) 64. Negative Bias Current 4 @ +5V (A) 65. Positive Output Voltage 1 RL=open @ +5V (V) 66. Positive Output Voltage 2 RL=open @ +5V (V) 67. Positive Output Voltage 3 RL=open @ +5V (V) 68. Positive Output Voltage 4 RL=open @ +5V (V) 69. Positive Output Voltage 1 RL=600 @ +5V (V) 70. Positive Output Voltage 2 RL=600 @ +5V (V) 71. Positive Output Voltage 3 RL=600 @ +5V (V) 72. Positive Output Voltage 4 RL=600 @ +5V (V) 73. Output Voltage Low 1 RL=open @ +5V (V) 74. Output Voltage Low 2 RL=open @ +5V (V) 75. Output Voltage Low 3 RL=open @ +5V (V) 76. Output Voltage Low 4 RL=open @ +5V (V) 77. Output Voltage Low 1 RL=600 @ +5V (V) 78. Output Voltage Low 2 RL=600 @ +5V (V) 79. Output Voltage Low 4 RL=600 @ +5V (V) An ISO 9001:2008 and DSCC Certified Company 6 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 80. Output Voltage Low 3 RL=600 @ +5V (V) 81. Output Voltage Low 1 IL=1mA @ +5V (V) 82. Output Voltage Low 2 IL=1mA @ +5V (V) 83. Output Voltage Low 3 IL=1mA @ +5V (V) 84. Output Voltage Low 4 IL=1mA @ +5V (V) Appendix C details the measured parameters, test conditions, pre-irradiation specification and measurement resolution for each of the measurements. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the low dose rate test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. Further, MIL-STD-883H, TM 1019.8 Section 3.13.1.1 Characterization test to determine if a part exhibits ELDRS' states the following: Select a minimum random sample of 21 devices from a population representative of recent production runs. Smaller sample sizes may be used if agreed upon between the parties to the test. All of the selected devices shall have undergone appropriate elevated temperature reliability screens, e.g. burn-in and high temperature storage life. Divide the samples into four groups of 5 each and use the remaining part for a control. Perform pre-irradiation electrical characterization on all parts assuring that they meet the Group A electrical tests. Irradiate 5 samples under a 0 volt bias and another 5 under the irradiation bias given in the acquisition specification at 50300 rad(Si)/s and room temperature. Irradiate 5 samples under a 0 volt bias and another 5 under irradiation bias given in the acquisition specification at < 10mrad(Si)/s and room temperature. Irradiate all samples to the same dose levels, including 0.5 and 1.0 times the anticipated specification dose, and repeat the electrical characterization on each part at each dose level. Post irradiation electrical measurements shall be performed per paragraph 3.10 where the low dose rate test is considered Condition D. Calculate the radiation induced change in each electrical parameter (∆para) for each sample at each radiation level. Calculate the ratio of the median ∆para at low dose rate to the median ∆para at high dose rate for each irradiation bias group at each total dose level. If this ratio exceeds 1.5 for any of the most sensitive parameters then the part is considered to be ELDRS susceptible. This test does not apply to parameters which exhibit changes that are within experimental error or whose values are below the pre-irradiation electrical specification limits at low dose rate at the specification dose. Therefore, the data in this report can be analyzed along with the high dose rate report titled "Total An ISO 9001:2008 and DSCC Certified Company 7 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ionizing Dose (TID) Radiation Testing of the RH1014MW Quad Precision Operational Amplifier for Linear Technology" to demonstrate that these parts do not exhibit ELDRS as defined in the current test method. 5.0. ELDRS Test Results Based on this criterion the RH1014MW Quad Precision Operational Amplifier (from the lot traceability information provided on the first page of this test report) PASSED the enhanced low dose rate sensitivity test to the maximum tested dose level of 50krad(Si) with all parameters remaining within their datasheet specifications. Figures 5.1 through 5.84 show plots of all the measured parameters versus total ionizing dose while Tables 5.1 - 5.84 show the corresponding raw data for each of these parameters. In the data plots the solid diamonds are the average of the measured data points for the sample irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the units irradiated with all pins tied to ground. The black lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. In addition to the radiation test results, the data plots and tables described above contain anneal data. The anneals are performed to better understand the underlying physical mechanisms responsible for radiation-induced parametric shifts and are not part of the criteria used to establish whether or not the lot passes or fails the low dose rate test. In all cases the parts either improved or exhibited no change during the anneal. The control units, as expected, show no significant changes to any of the parameters. Therefore we can conclude that the electrical testing remained in control throughout the duration of the tests and the observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section to facilitate the location of a particular parameter. An ISO 9001:2008 and DSCC Certified Company 8 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Positive Supply Current @ +/-15V (A) 2.50E-03 2.00E-03 1.50E-03 1.00E-03 5.00E-04 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.1. Plot of Positive Supply Current @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 9 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.1. Raw data for Positive Supply Current @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Positive Supply Current @ +/-15V (A) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 1.59E-03 1.60E-03 1.57E-03 1.54E-03 1.47E-03 1.47E-03 1.45E-03 1842 1.53E-03 1.52E-03 1.51E-03 1.49E-03 1.42E-03 1.42E-03 1.39E-03 1843 1.56E-03 1.57E-03 1.54E-03 1.51E-03 1.44E-03 1.44E-03 1.41E-03 1844 1.52E-03 1.54E-03 1.52E-03 1.49E-03 1.43E-03 1.42E-03 1.39E-03 1845 1.54E-03 1.55E-03 1.53E-03 1.50E-03 1.44E-03 1.43E-03 1.40E-03 1846 1.59E-03 1.62E-03 1.60E-03 1.57E-03 1.55E-03 1.54E-03 1.53E-03 1847 1.55E-03 1.61E-03 1.59E-03 1.57E-03 1.54E-03 1.53E-03 1.52E-03 1848 1.52E-03 1.58E-03 1.56E-03 1.54E-03 1.51E-03 1.51E-03 1.50E-03 1849 1.55E-03 1.60E-03 1.58E-03 1.57E-03 1.54E-03 1.53E-03 1.52E-03 1850 1.61E-03 1.67E-03 1.65E-03 1.63E-03 1.60E-03 1.59E-03 1.58E-03 1851 1.53E-03 1.53E-03 1.53E-03 1.53E-03 1.53E-03 1.53E-03 1.53E-03 1852 1.58E-03 1.58E-03 1.58E-03 1.57E-03 1.58E-03 1.57E-03 1.57E-03 Biased Statistics Average Biased 1.55E-03 1.56E-03 1.53E-03 1.51E-03 1.44E-03 1.44E-03 1.41E-03 Std Dev Biased 3.01E-05 3.20E-05 2.42E-05 2.10E-05 1.88E-05 2.08E-05 2.60E-05 Ps90%/90% (+KTL) Biased 1.63E-03 1.64E-03 1.60E-03 1.56E-03 1.49E-03 1.50E-03 1.48E-03 Ps90%/90% (-KTL) Biased 1.46E-03 1.47E-03 1.47E-03 1.45E-03 1.39E-03 1.38E-03 1.33E-03 Un-Biased Statistics Average Un-Biased 1.56E-03 1.62E-03 1.60E-03 1.57E-03 1.55E-03 1.54E-03 1.53E-03 Std Dev Un-Biased 3.49E-05 3.21E-05 3.26E-05 3.25E-05 3.28E-05 3.26E-05 3.21E-05 Ps90%/90% (+KTL) Un-Biased 1.66E-03 1.70E-03 1.68E-03 1.66E-03 1.64E-03 1.63E-03 1.62E-03 Ps90%/90% (-KTL) Un-Biased 1.47E-03 1.53E-03 1.51E-03 1.49E-03 1.46E-03 1.45E-03 1.44E-03 Specification MAX 2.20E-03 2.20E-03 2.20E-03 2.20E-03 2.20E-03 2.20E-03 2.20E-03 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 10 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Negative Supply Current @ +/-15V (A) 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 -2.00E-03 -2.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.2. Plot of Negative Supply Current @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 11 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.2. Raw data for Negative Supply Current @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Supply Current @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -1.59E-03 -1.60E-03 -1.57E-03 -1.54E-03 1842 -1.53E-03 -1.52E-03 -1.51E-03 -1.48E-03 1843 -1.56E-03 -1.57E-03 -1.54E-03 -1.51E-03 1844 -1.52E-03 -1.54E-03 -1.52E-03 -1.49E-03 1845 -1.54E-03 -1.55E-03 -1.53E-03 -1.50E-03 1846 -1.59E-03 -1.61E-03 -1.60E-03 -1.57E-03 1847 -1.55E-03 -1.61E-03 -1.59E-03 -1.57E-03 1848 -1.52E-03 -1.58E-03 -1.56E-03 -1.54E-03 1849 -1.55E-03 -1.60E-03 -1.58E-03 -1.57E-03 1850 -1.60E-03 -1.67E-03 -1.65E-03 -1.63E-03 1851 -1.54E-03 -1.53E-03 -1.53E-03 -1.53E-03 1852 -1.58E-03 -1.58E-03 -1.58E-03 -1.57E-03 Biased Statistics Average Biased -1.55E-03 -1.56E-03 -1.53E-03 -1.50E-03 Std Dev Biased 3.00E-05 3.13E-05 2.44E-05 2.10E-05 Ps90%/90% (+KTL) Biased -1.46E-03 -1.47E-03 -1.47E-03 -1.45E-03 Ps90%/90% (-KTL) Biased -1.63E-03 -1.64E-03 -1.60E-03 -1.56E-03 Un-Biased Statistics Average Un-Biased -1.56E-03 -1.61E-03 -1.59E-03 -1.57E-03 Std Dev Un-Biased 3.44E-05 3.33E-05 3.19E-05 3.30E-05 Ps90%/90% (+KTL) Un-Biased -1.47E-03 -1.52E-03 -1.51E-03 -1.48E-03 Ps90%/90% (-KTL) Un-Biased -1.66E-03 -1.71E-03 -1.68E-03 -1.67E-03 Specification MIN -2.20E-03 -2.20E-03 -2.20E-03 -2.20E-03 Status PASS PASS PASS PASS 50 1/27/2011 -1.47E-03 -1.42E-03 -1.44E-03 -1.43E-03 -1.44E-03 -1.55E-03 -1.54E-03 -1.52E-03 -1.53E-03 -1.60E-03 -1.53E-03 -1.58E-03 168 hr Anneal 70 2/4/2011 -1.45E-03 -1.39E-03 -1.41E-03 -1.39E-03 -1.40E-03 -1.54E-03 -1.53E-03 -1.50E-03 -1.52E-03 -1.58E-03 -1.53E-03 -1.57E-03 -1.44E-03 -1.44E-03 -1.41E-03 1.85E-05 2.16E-05 2.55E-05 -1.39E-03 -1.38E-03 -1.34E-03 -1.49E-03 -1.50E-03 -1.48E-03 -1.55E-03 3.24E-05 -1.46E-03 -1.64E-03 -2.20E-03 PASS An ISO 9001:2008 and DSCC Certified Company 12 24 hr Anneal 60 1/28/2011 -1.48E-03 -1.42E-03 -1.44E-03 -1.42E-03 -1.43E-03 -1.54E-03 -1.53E-03 -1.51E-03 -1.53E-03 -1.60E-03 -1.53E-03 -1.57E-03 -1.54E-03 3.33E-05 -1.45E-03 -1.63E-03 -2.20E-03 PASS -1.53E-03 3.10E-05 -1.45E-03 -1.62E-03 -2.20E-03 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-04 Offset Voltage 1 @ +/-15V (V) 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.3. Plot of Offset Voltage 1 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 13 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.3. Raw data for Offset Voltage 1 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Voltage 1 @ +/-15V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 8.51E-06 4.10E-05 4.80E-05 5.75E-05 1842 -2.11E-05 -1.46E-05 -8.04E-06 2.10E-06 1843 -7.20E-05 -6.21E-05 -5.72E-05 -4.96E-05 1844 2.83E-06 4.16E-06 1.14E-05 1.94E-05 1845 -8.65E-05 -8.14E-05 -7.52E-05 -6.31E-05 1846 -5.37E-05 -4.84E-05 -4.28E-05 -3.89E-05 1847 1.63E-06 5.25E-06 9.71E-06 1.60E-05 1848 7.66E-06 1.21E-05 1.64E-05 2.05E-05 1849 1.33E-05 1.87E-05 2.28E-05 2.73E-05 1850 -1.11E-05 -5.98E-06 -2.49E-06 1.98E-06 1851 2.72E-05 2.58E-05 2.70E-05 2.59E-05 1852 5.37E-05 5.34E-05 5.29E-05 5.21E-05 Biased Statistics Average Biased -3.37E-05 -2.26E-05 -1.62E-05 -6.73E-06 Std Dev Biased 4.34E-05 4.96E-05 5.03E-05 4.97E-05 Ps90%/90% (+KTL) Biased 8.53E-05 1.13E-04 1.22E-04 1.30E-04 Ps90%/90% (-KTL) Biased -1.53E-04 -1.59E-04 -1.54E-04 -1.43E-04 Un-Biased Statistics Average Un-Biased -8.42E-06 -3.66E-06 7.02E-07 5.37E-06 Std Dev Un-Biased 2.69E-05 2.66E-05 2.61E-05 2.64E-05 Ps90%/90% (+KTL) Un-Biased 6.53E-05 6.93E-05 7.21E-05 7.79E-05 Ps90%/90% (-KTL) Un-Biased -8.21E-05 -7.66E-05 -7.07E-05 -6.72E-05 Specification MIN -3.00E-04 -4.50E-04 -4.50E-04 -4.50E-04 Status PASS PASS PASS PASS Specification MAX 3.00E-04 4.50E-04 4.50E-04 4.50E-04 Status PASS PASS PASS PASS 50 1/27/2011 7.45E-05 1.59E-05 -3.44E-05 3.88E-05 -4.43E-05 -2.82E-05 2.64E-05 3.07E-05 3.59E-05 8.02E-06 2.61E-05 5.09E-05 1.01E-05 8.58E-06 2.99E-05 4.98E-05 5.09E-05 5.78E-05 1.47E-04 1.48E-04 1.88E-04 -1.27E-04 -1.31E-04 -1.29E-04 1.46E-05 2.61E-05 8.62E-05 -5.70E-05 -6.00E-04 PASS 6.00E-04 PASS An ISO 9001:2008 and DSCC Certified Company 14 24 hr 168 hr Anneal Anneal 60 70 1/28/2011 2/4/2011 7.60E-05 1.27E-04 1.38E-05 3.27E-05 -3.67E-05 1.26E-06 3.60E-05 1.15E-05 -4.63E-05 -2.30E-05 -2.65E-05 -3.01E-05 2.94E-05 3.14E-05 2.93E-05 4.04E-05 3.71E-05 4.10E-05 8.87E-06 7.42E-06 2.63E-05 2.75E-05 5.15E-05 5.14E-05 1.56E-05 2.58E-05 8.63E-05 -5.51E-05 -6.00E-04 PASS 6.00E-04 PASS 1.80E-05 3.02E-05 1.01E-04 -6.47E-05 -6.00E-04 PASS 6.00E-04 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-04 Offset Voltage 2 @ +/-15V (V) 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.4. Plot of Offset Voltage 2 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 15 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.4. Raw data for Offset Voltage 2 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Voltage 2 @ +/-15V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 4.64E-05 3.15E-05 3.91E-05 4.28E-05 1842 8.20E-05 7.99E-05 8.99E-05 9.78E-05 1843 6.61E-05 7.06E-05 8.26E-05 8.89E-05 1844 3.27E-05 3.33E-05 4.63E-05 5.33E-05 1845 3.51E-05 3.30E-05 4.51E-05 5.46E-05 1846 5.04E-05 5.05E-05 5.10E-05 5.18E-05 1847 -2.99E-05 -2.83E-05 -2.47E-05 -1.60E-05 1848 5.10E-05 5.74E-05 6.03E-05 6.26E-05 1849 6.31E-05 6.53E-05 7.01E-05 7.41E-05 1850 3.47E-05 4.17E-05 4.67E-05 4.85E-05 1851 4.93E-05 5.04E-05 4.94E-05 4.88E-05 1852 -2.94E-05 -2.83E-05 -2.87E-05 -3.05E-05 Biased Statistics Average Biased 5.25E-05 4.96E-05 6.06E-05 6.75E-05 Std Dev Biased 2.12E-05 2.36E-05 2.37E-05 2.43E-05 Ps90%/90% (+KTL) Biased 1.10E-04 1.14E-04 1.26E-04 1.34E-04 Ps90%/90% (-KTL) Biased -5.58E-06 -1.51E-05 -4.48E-06 9.25E-07 Un-Biased Statistics Average Un-Biased 3.39E-05 3.73E-05 4.07E-05 4.42E-05 Std Dev Un-Biased 3.70E-05 3.77E-05 3.76E-05 3.51E-05 Ps90%/90% (+KTL) Un-Biased 1.35E-04 1.41E-04 1.44E-04 1.40E-04 Ps90%/90% (-KTL) Un-Biased -6.77E-05 -6.60E-05 -6.25E-05 -5.21E-05 Specification MIN -3.00E-04 -4.50E-04 -4.50E-04 -4.50E-04 Status PASS PASS PASS PASS Specification MAX 3.00E-04 4.50E-04 4.50E-04 4.50E-04 Status PASS PASS PASS PASS 50 1/27/2011 5.73E-05 1.17E-04 1.03E-04 7.23E-05 7.73E-05 6.21E-05 -6.70E-07 7.66E-05 8.70E-05 6.13E-05 4.90E-05 -2.83E-05 24 hr 168 hr Anneal Anneal 60 70 1/28/2011 2/4/2011 5.64E-05 3.11E-05 1.14E-04 1.14E-04 1.05E-04 7.66E-05 7.21E-05 6.96E-05 7.56E-05 7.01E-05 5.93E-05 8.38E-06 -1.64E-06 -2.46E-05 7.44E-05 7.26E-05 8.47E-05 6.63E-05 6.15E-05 5.26E-05 4.90E-05 4.83E-05 -2.88E-05 -2.97E-05 8.53E-05 2.41E-05 1.51E-04 1.93E-05 8.46E-05 7.22E-05 2.40E-05 2.93E-05 1.50E-04 1.53E-04 1.88E-05 -8.22E-06 5.73E-05 3.41E-05 1.51E-04 -3.63E-05 -6.00E-04 PASS 6.00E-04 PASS An ISO 9001:2008 and DSCC Certified Company 16 5.57E-05 3.36E-05 1.48E-04 -3.66E-05 -6.00E-04 PASS 6.00E-04 PASS 3.51E-05 4.17E-05 1.49E-04 -7.93E-05 -6.00E-04 PASS 6.00E-04 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-04 Offset Voltage 3 @ +/-15V (V) 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.5. Plot of Offset Voltage 3 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 17 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.5. Raw data for Offset Voltage 3 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Voltage 3 @ +/-15V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 7.80E-07 -1.80E-07 4.40E-06 7.66E-06 1842 1.87E-06 1.80E-07 7.66E-06 1.32E-05 1843 -7.02E-05 -6.74E-05 -6.06E-05 -5.42E-05 1844 -1.46E-05 -1.48E-05 -5.74E-06 9.00E-07 1845 -2.74E-05 -2.67E-05 -1.83E-05 -1.25E-05 1846 5.79E-05 5.84E-05 5.97E-05 6.11E-05 1847 9.41E-05 9.81E-05 1.05E-04 1.10E-04 1848 -1.50E-05 -9.60E-06 1.98E-06 8.14E-06 1849 -7.15E-05 -6.76E-05 -6.08E-05 -5.45E-05 1850 5.06E-05 5.73E-05 6.33E-05 6.57E-05 1851 -1.46E-05 -1.29E-05 -1.34E-05 -1.37E-05 1852 1.64E-05 1.56E-05 1.61E-05 1.33E-05 Biased Statistics Average Biased -2.19E-05 -2.18E-05 -1.45E-05 -8.98E-06 Std Dev Biased 2.96E-05 2.79E-05 2.77E-05 2.70E-05 Ps90%/90% (+KTL) Biased 5.92E-05 5.46E-05 6.13E-05 6.51E-05 Ps90%/90% (-KTL) Biased -1.03E-04 -9.82E-05 -9.04E-05 -8.31E-05 Un-Biased Statistics Average Un-Biased 2.32E-05 2.73E-05 3.39E-05 3.80E-05 Std Dev Un-Biased 6.60E-05 6.56E-05 6.45E-05 6.30E-05 Ps90%/90% (+KTL) Un-Biased 2.04E-04 2.07E-04 2.11E-04 2.11E-04 Ps90%/90% (-KTL) Un-Biased -1.58E-04 -1.53E-04 -1.43E-04 -1.35E-04 Specification MIN -3.00E-04 -4.50E-04 -4.50E-04 -4.50E-04 Status PASS PASS PASS PASS Specification MAX 3.00E-04 4.50E-04 4.50E-04 4.50E-04 Status PASS PASS PASS PASS 50 1/27/2011 1.85E-05 2.90E-05 -3.60E-05 1.60E-05 1.01E-05 6.74E-05 1.27E-04 2.29E-05 -3.89E-05 7.88E-05 -1.41E-05 1.52E-05 7.52E-06 6.62E-06 1.31E-05 2.53E-05 2.42E-05 1.78E-05 7.69E-05 7.30E-05 6.18E-05 -6.18E-05 -5.98E-05 -3.56E-05 5.15E-05 6.27E-05 2.23E-04 -1.20E-04 -6.00E-04 PASS 6.00E-04 PASS An ISO 9001:2008 and DSCC Certified Company 18 24 hr 168 hr Anneal Anneal 60 70 1/28/2011 2/4/2011 1.76E-05 2.26E-05 2.60E-05 1.24E-05 -3.52E-05 -1.71E-05 1.66E-05 1.99E-05 8.14E-06 2.77E-05 6.74E-05 4.83E-05 1.25E-04 1.14E-04 2.29E-05 1.97E-05 -4.26E-05 -3.99E-05 8.02E-05 7.59E-05 -1.31E-05 -1.32E-05 1.45E-05 1.43E-05 5.07E-05 6.37E-05 2.25E-04 -1.24E-04 -6.00E-04 PASS 6.00E-04 PASS 4.37E-05 5.83E-05 2.04E-04 -1.16E-04 -6.00E-04 PASS 6.00E-04 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-04 Offset Voltage 4 @ +/-15V (V) 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.6. Plot of Offset Voltage 4 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 19 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.6. Raw data for Offset Voltage 4 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Voltage 4 @ +/-15V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 9.00E-07 -5.01E-06 2.22E-06 1.26E-05 1842 -1.32E-05 -1.08E-05 -5.50E-07 4.28E-06 1843 7.39E-05 7.90E-05 8.32E-05 8.82E-05 1844 8.25E-05 8.46E-05 9.19E-05 1.05E-04 1845 5.14E-05 5.11E-05 5.66E-05 6.44E-05 1846 3.82E-05 3.71E-05 4.22E-05 4.70E-05 1847 6.43E-05 6.56E-05 6.81E-05 7.54E-05 1848 3.54E-05 3.87E-05 4.24E-05 4.61E-05 1849 1.71E-05 1.90E-05 2.44E-05 2.88E-05 1850 -7.14E-05 -6.45E-05 -6.06E-05 -5.36E-05 1851 9.23E-05 9.23E-05 9.25E-05 9.16E-05 1852 1.23E-04 1.22E-04 1.22E-04 1.21E-04 Biased Statistics Average Biased 3.91E-05 3.98E-05 4.67E-05 5.48E-05 Std Dev Biased 4.31E-05 4.54E-05 4.38E-05 4.48E-05 Ps90%/90% (+KTL) Biased 1.57E-04 1.64E-04 1.67E-04 1.78E-04 Ps90%/90% (-KTL) Biased -7.92E-05 -8.47E-05 -7.35E-05 -6.80E-05 Un-Biased Statistics Average Un-Biased 1.67E-05 1.92E-05 2.33E-05 2.87E-05 Std Dev Un-Biased 5.21E-05 4.97E-05 4.94E-05 4.89E-05 Ps90%/90% (+KTL) Un-Biased 1.59E-04 1.55E-04 1.59E-04 1.63E-04 Ps90%/90% (-KTL) Un-Biased -1.26E-04 -1.17E-04 -1.12E-04 -1.05E-04 Specification MIN -3.00E-04 -4.50E-04 -4.50E-04 -4.50E-04 Status PASS PASS PASS PASS Specification MAX 3.00E-04 4.50E-04 4.50E-04 4.50E-04 Status PASS PASS PASS PASS 50 1/27/2011 3.11E-05 2.31E-05 9.50E-05 1.28E-04 8.49E-05 5.56E-05 8.07E-05 6.36E-05 3.86E-05 -3.95E-05 9.23E-05 1.20E-04 7.24E-05 7.13E-05 6.86E-05 4.44E-05 4.38E-05 5.59E-05 1.94E-04 1.91E-04 2.22E-04 -4.92E-05 -4.89E-05 -8.47E-05 3.98E-05 4.69E-05 1.68E-04 -8.87E-05 -6.00E-04 PASS 6.00E-04 PASS An ISO 9001:2008 and DSCC Certified Company 20 24 hr 168 hr Anneal Anneal 60 70 1/28/2011 2/4/2011 3.24E-05 1.56E-05 2.17E-05 7.66E-06 9.56E-05 8.92E-05 1.26E-04 1.40E-04 8.02E-05 9.10E-05 5.56E-05 3.29E-05 8.26E-05 6.38E-05 6.14E-05 6.63E-05 4.21E-05 2.61E-05 -3.80E-05 -3.42E-05 9.24E-05 9.25E-05 1.20E-04 1.20E-04 4.07E-05 4.64E-05 1.68E-04 -8.64E-05 -6.00E-04 PASS 6.00E-04 PASS 3.10E-05 4.06E-05 1.42E-04 -8.04E-05 -6.00E-04 PASS 6.00E-04 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.00E-08 Offset Current 1 @ +/-15V (A) 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.7. Plot of Offset Current 1 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 21 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.7. Raw data for Offset Current 1 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Current 1 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -5.90E-11 -7.00E-11 -8.90E-11 -1.13E-10 1842 -1.22E-10 -1.37E-10 -9.60E-11 -4.60E-11 1843 -1.70E-11 2.60E-11 3.50E-11 9.10E-11 1844 -9.00E-12 1.50E-11 4.00E-12 7.30E-11 1845 -5.60E-11 -8.80E-11 -1.77E-10 -3.13E-10 1846 6.00E-11 -1.40E-11 -5.20E-11 -2.30E-11 1847 -6.10E-11 -2.00E-11 -8.00E-12 -5.90E-11 1848 -4.70E-11 -5.10E-11 -8.30E-11 -1.04E-10 1849 -1.40E-11 -3.30E-11 -5.50E-11 -1.05E-10 1850 -2.40E-11 1.00E-11 -3.30E-11 -1.03E-10 1851 2.90E-11 1.80E-11 1.90E-11 3.10E-11 1852 -1.50E-11 -2.90E-11 -1.30E-11 -1.50E-11 Biased Statistics Average Biased -5.26E-11 -5.08E-11 -6.46E-11 -6.16E-11 Std Dev Biased 4.48E-11 6.97E-11 8.49E-11 1.64E-10 Ps90%/90% (+KTL) Biased 7.03E-11 1.40E-10 1.68E-10 3.88E-10 Ps90%/90% (-KTL) Biased -1.76E-10 -2.42E-10 -2.97E-10 -5.11E-10 Un-Biased Statistics Average Un-Biased -1.72E-11 -2.16E-11 -4.62E-11 -7.88E-11 Std Dev Un-Biased 4.70E-11 2.27E-11 2.78E-11 3.68E-11 Ps90%/90% (+KTL) Un-Biased 1.12E-10 4.05E-11 3.01E-11 2.21E-11 Ps90%/90% (-KTL) Un-Biased -1.46E-10 -8.37E-11 -1.23E-10 -1.80E-10 Specification MIN -1.00E-08 -1.00E-08 -1.00E-08 -1.00E-08 Status PASS PASS PASS PASS Specification MAX 1.00E-08 1.00E-08 1.00E-08 1.00E-08 Status PASS PASS PASS PASS 50 1/27/2011 -5.60E-11 -1.56E-10 1.62E-10 1.51E-10 -4.10E-10 -1.24E-10 1.43E-10 -5.50E-11 -9.20E-11 -5.60E-11 4.50E-11 -9.00E-12 168 hr Anneal 70 2/4/2011 -4.90E-11 -1.03E-10 -9.90E-11 3.10E-11 -2.01E-10 -6.40E-11 -1.80E-11 -1.07E-10 -8.40E-11 7.20E-11 4.00E-11 -6.00E-12 -6.18E-11 -5.78E-11 -8.42E-11 2.37E-10 2.56E-10 8.47E-11 5.89E-10 6.44E-10 1.48E-10 -7.13E-10 -7.60E-10 -3.17E-10 -3.68E-11 1.04E-10 2.50E-10 -3.23E-10 -1.50E-08 PASS 1.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 22 24 hr Anneal 60 1/28/2011 -3.00E-11 -1.21E-10 1.24E-10 1.96E-10 -4.58E-10 -9.00E-11 6.90E-11 -5.20E-11 -7.60E-11 -1.48E-10 4.20E-11 -2.10E-11 -5.94E-11 8.00E-11 1.60E-10 -2.79E-10 -1.50E-08 PASS 1.50E-08 PASS -4.02E-11 7.08E-11 1.54E-10 -2.34E-10 -1.50E-08 PASS 1.50E-08 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.00E-08 Offset Current 2 @ +/-15V (A) 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.8. Plot of Offset Current 2 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 23 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.8. Raw data for Offset Current 2 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Current 2 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -5.70E-11 -9.20E-11 -1.21E-10 -8.30E-11 1842 -1.17E-10 -1.42E-10 -2.57E-10 -2.77E-10 1843 -2.00E-12 -6.20E-11 -1.70E-11 -9.50E-11 1844 -4.70E-11 -3.70E-11 5.20E-11 1.44E-10 1845 -6.40E-11 -3.50E-11 -2.70E-11 -1.27E-10 1846 -3.90E-11 3.00E-11 1.40E-11 -9.00E-12 1847 -1.00E-11 6.30E-11 5.40E-11 1.41E-10 1848 -1.06E-10 -1.05E-10 -4.80E-11 2.00E-11 1849 2.50E-11 4.00E-12 -1.00E-11 -1.00E-11 1850 -1.73E-10 -1.66E-10 -1.83E-10 -2.11E-10 1851 -1.43E-10 -1.49E-10 -1.37E-10 -1.32E-10 1852 -1.77E-10 -1.69E-10 -1.74E-10 -1.81E-10 Biased Statistics Average Biased -5.74E-11 -7.36E-11 -7.40E-11 -8.76E-11 Std Dev Biased 4.11E-11 4.47E-11 1.19E-10 1.51E-10 Ps90%/90% (+KTL) Biased 5.54E-11 4.89E-11 2.53E-10 3.26E-10 Ps90%/90% (-KTL) Biased -1.70E-10 -1.96E-10 -4.01E-10 -5.01E-10 Un-Biased Statistics Average Un-Biased -6.06E-11 -3.48E-11 -3.46E-11 -1.38E-11 Std Dev Un-Biased 7.91E-11 9.67E-11 9.09E-11 1.27E-10 Ps90%/90% (+KTL) Un-Biased 1.56E-10 2.30E-10 2.15E-10 3.33E-10 Ps90%/90% (-KTL) Un-Biased -2.78E-10 -3.00E-10 -2.84E-10 -3.61E-10 Specification MIN -1.00E-08 -1.00E-08 -1.00E-08 -1.00E-08 Status PASS PASS PASS PASS Specification MAX 1.00E-08 1.00E-08 1.00E-08 1.00E-08 Status PASS PASS PASS PASS 50 1/27/2011 -1.94E-10 -3.27E-10 -1.42E-10 1.87E-10 -2.40E-11 2.15E-10 5.80E-11 -9.30E-11 -1.31E-10 -2.63E-10 -1.40E-10 -1.84E-10 168 hr Anneal 70 2/4/2011 -1.35E-10 -2.30E-10 3.20E-11 -3.40E-11 6.70E-11 8.40E-11 5.60E-11 -3.10E-11 8.10E-11 -2.51E-10 -1.36E-10 -1.70E-10 -1.00E-10 -9.36E-11 -6.00E-11 1.94E-10 1.84E-10 1.22E-10 4.31E-10 4.10E-10 2.75E-10 -6.31E-10 -5.97E-10 -3.95E-10 -4.28E-11 1.84E-10 4.62E-10 -5.47E-10 -1.50E-08 PASS 1.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 24 24 hr Anneal 60 1/28/2011 -1.57E-10 -2.97E-10 -1.51E-10 1.98E-10 -6.10E-11 2.05E-10 5.50E-11 -6.20E-11 -1.25E-10 -2.68E-10 -1.33E-10 -1.94E-10 -3.90E-11 1.79E-10 4.53E-10 -5.31E-10 -1.50E-08 PASS 1.50E-08 PASS -1.22E-11 1.41E-10 3.76E-10 -4.00E-10 -1.50E-08 PASS 1.50E-08 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.00E-08 Offset Current 3 @ +/-15V (A) 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.9. Plot of Offset Current 3 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 25 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.9. Raw data for Offset Current 3 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Current 3 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -2.50E-11 3.30E-11 7.00E-12 9.80E-11 1842 -7.00E-12 5.20E-11 1.27E-10 1.18E-10 1843 9.00E-11 -1.50E-11 -2.20E-11 7.30E-11 1844 -5.40E-11 1.10E-11 -2.20E-11 8.50E-11 1845 -4.60E-11 -9.50E-11 -1.59E-10 -7.90E-11 1846 -8.60E-11 -8.40E-11 -1.70E-11 -1.05E-10 1847 -5.30E-11 2.60E-11 4.20E-11 7.90E-11 1848 -1.01E-10 -2.40E-11 -1.70E-11 -2.50E-11 1849 1.00E-11 9.00E-12 6.10E-11 -7.00E-12 1850 -7.80E-11 -6.20E-11 -8.00E-11 3.00E-11 1851 -1.24E-10 -1.49E-10 -1.67E-10 -1.47E-10 1852 1.25E-10 7.70E-11 1.24E-10 1.01E-10 Biased Statistics Average Biased -8.40E-12 -2.80E-12 -1.38E-11 5.90E-11 Std Dev Biased 5.80E-11 5.73E-11 1.02E-10 7.89E-11 Ps90%/90% (+KTL) Biased 1.51E-10 1.54E-10 2.65E-10 2.75E-10 Ps90%/90% (-KTL) Biased -1.67E-10 -1.60E-10 -2.93E-10 -1.57E-10 Un-Biased Statistics Average Un-Biased -6.16E-11 -2.70E-11 -2.20E-12 -5.60E-12 Std Dev Un-Biased 4.36E-11 4.63E-11 5.58E-11 6.83E-11 Ps90%/90% (+KTL) Un-Biased 5.81E-11 1.00E-10 1.51E-10 1.82E-10 Ps90%/90% (-KTL) Un-Biased -1.81E-10 -1.54E-10 -1.55E-10 -1.93E-10 Specification MIN -1.00E-08 -1.00E-08 -1.00E-08 -1.00E-08 Status PASS PASS PASS PASS Specification MAX 1.00E-08 1.00E-08 1.00E-08 1.00E-08 Status PASS PASS PASS PASS 50 1/27/2011 5.10E-11 2.17E-10 1.81E-10 1.67E-10 -2.60E-11 -5.00E-12 1.32E-10 -9.40E-11 -5.30E-11 7.30E-11 -1.65E-10 1.39E-10 168 hr Anneal 70 2/4/2011 1.16E-10 1.54E-10 2.82E-10 3.10E-11 -1.23E-10 -7.20E-11 1.05E-10 -8.50E-11 3.60E-11 1.16E-10 -1.41E-10 1.22E-10 1.18E-10 1.18E-10 9.20E-11 1.02E-10 1.11E-10 1.50E-10 3.97E-10 4.23E-10 5.04E-10 -1.61E-10 -1.87E-10 -3.20E-10 1.06E-11 9.20E-11 2.63E-10 -2.42E-10 -1.50E-08 PASS 1.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 26 24 hr Anneal 60 1/28/2011 1.09E-10 2.18E-10 1.78E-10 1.52E-10 -6.80E-11 -2.30E-11 1.31E-10 -1.43E-10 -5.40E-11 2.80E-11 -1.51E-10 1.05E-10 -1.22E-11 1.01E-10 2.66E-10 -2.90E-10 -1.50E-08 PASS 1.50E-08 PASS 2.00E-11 9.51E-11 2.81E-10 -2.41E-10 -1.50E-08 PASS 1.50E-08 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.00E-08 Offset Current 4 @ +/-15V (A) 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.10. Plot of Offset Current 4 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 27 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.10. Raw data for Offset Current 4 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Current 4 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -1.53E-10 -2.48E-10 -3.15E-10 -3.64E-10 1842 -1.41E-10 -1.26E-10 -1.65E-10 -1.51E-10 1843 -4.50E-11 -2.20E-11 -5.80E-11 -1.40E-11 1844 1.20E-10 2.35E-10 2.52E-10 1.12E-10 1845 -1.08E-10 -1.06E-10 -1.25E-10 -1.33E-10 1846 -5.55E-10 -3.90E-11 -3.20E-11 -1.66E-10 1847 -8.00E-12 3.90E-11 8.60E-11 6.30E-11 1848 -1.11E-10 -1.93E-10 -2.65E-10 -2.60E-10 1849 -9.80E-11 -1.12E-10 -1.39E-10 -1.40E-10 1850 -1.99E-10 -1.69E-10 -1.71E-10 -2.39E-10 1851 1.20E-11 5.00E-12 -2.00E-12 8.00E-12 1852 -5.00E-12 -2.70E-11 -1.50E-11 -9.00E-12 Biased Statistics Average Biased -6.54E-11 -5.34E-11 -8.22E-11 -1.10E-10 Std Dev Biased 1.12E-10 1.80E-10 2.09E-10 1.77E-10 Ps90%/90% (+KTL) Biased 2.41E-10 4.41E-10 4.92E-10 3.75E-10 Ps90%/90% (-KTL) Biased -3.72E-10 -5.48E-10 -6.56E-10 -5.95E-10 Un-Biased Statistics Average Un-Biased -1.94E-10 -9.48E-11 -1.04E-10 -1.48E-10 Std Dev Un-Biased 2.13E-10 9.55E-11 1.35E-10 1.28E-10 Ps90%/90% (+KTL) Un-Biased 3.89E-10 1.67E-10 2.66E-10 2.03E-10 Ps90%/90% (-KTL) Un-Biased -7.78E-10 -3.57E-10 -4.74E-10 -5.00E-10 Specification MIN -1.00E-08 -1.00E-08 -1.00E-08 -1.00E-08 Status PASS PASS PASS PASS Specification MAX 1.00E-08 1.00E-08 1.00E-08 1.00E-08 Status PASS PASS PASS PASS 50 1/27/2011 -5.22E-10 -2.07E-10 8.50E-11 2.19E-10 -1.06E-10 -4.80E-11 1.71E-10 -3.75E-10 -2.23E-10 -2.15E-10 7.00E-12 -1.30E-11 168 hr Anneal 70 2/4/2011 -3.45E-10 -1.34E-10 -7.30E-11 2.23E-10 -1.23E-10 -3.10E-11 1.31E-10 -2.98E-10 -1.06E-10 -2.21E-10 0.00E+00 -4.00E-12 -1.06E-10 -7.12E-11 -9.04E-11 2.85E-10 2.65E-10 2.04E-10 6.76E-10 6.55E-10 4.69E-10 -8.88E-10 -7.97E-10 -6.50E-10 -1.38E-10 2.08E-10 4.32E-10 -7.08E-10 -1.50E-08 PASS 1.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 28 24 hr Anneal 60 1/28/2011 -4.13E-10 -1.90E-10 8.20E-11 2.81E-10 -1.16E-10 -1.34E-10 5.70E-11 -4.15E-10 -3.79E-10 -2.93E-10 -5.00E-12 -2.90E-11 -2.33E-10 1.95E-10 3.02E-10 -7.67E-10 -1.50E-08 PASS 1.50E-08 PASS -1.05E-10 1.67E-10 3.54E-10 -5.64E-10 -1.50E-08 PASS 1.50E-08 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 1 @ +/-15V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.11. Plot of Positive Bias Current 1 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 29 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.11. Raw data for Positive Bias Current 1 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Bias Current 1 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.05E-08 1.31E-08 1.60E-08 1.90E-08 1842 1.08E-08 1.34E-08 1.62E-08 1.91E-08 1843 9.46E-09 1.20E-08 1.47E-08 1.76E-08 1844 1.15E-08 1.41E-08 1.70E-08 2.00E-08 1845 1.05E-08 1.31E-08 1.61E-08 1.93E-08 1846 1.13E-08 1.24E-08 1.42E-08 1.60E-08 1847 1.05E-08 1.22E-08 1.38E-08 1.56E-08 1848 1.09E-08 1.28E-08 1.45E-08 1.63E-08 1849 1.05E-08 1.23E-08 1.41E-08 1.58E-08 1850 1.14E-08 1.33E-08 1.51E-08 1.69E-08 1851 1.04E-08 1.04E-08 1.04E-08 1.04E-08 1852 1.06E-08 1.06E-08 1.06E-08 1.06E-08 Biased Statistics Average Biased 1.05E-08 1.31E-08 1.60E-08 1.90E-08 Std Dev Biased 7.37E-10 7.66E-10 8.30E-10 8.83E-10 Ps90%/90% (+KTL) Biased 1.26E-08 1.52E-08 1.83E-08 2.14E-08 Ps90%/90% (-KTL) Biased 8.53E-09 1.10E-08 1.37E-08 1.66E-08 Un-Biased Statistics Average Un-Biased 1.09E-08 1.26E-08 1.43E-08 1.61E-08 Std Dev Un-Biased 4.58E-10 4.75E-10 4.90E-10 5.11E-10 Ps90%/90% (+KTL) Un-Biased 1.22E-08 1.39E-08 1.57E-08 1.75E-08 Ps90%/90% (-KTL) Un-Biased 9.66E-09 1.13E-08 1.30E-08 1.47E-08 Specification MIN -3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 Status PASS PASS PASS PASS Specification MAX 3.00E-08 6.00E-08 7.50E-08 7.50E-08 Status PASS PASS PASS PASS 168 hr Anneal 70 2/4/2011 2.43E-08 2.44E-08 2.27E-08 2.57E-08 2.46E-08 1.86E-08 1.81E-08 1.89E-08 1.86E-08 1.96E-08 1.03E-08 1.06E-08 2.56E-08 1.01E-09 2.84E-08 2.29E-08 2.57E-08 1.01E-09 2.85E-08 2.29E-08 2.43E-08 1.09E-09 2.73E-08 2.14E-08 2.00E-08 2.00E-08 1.88E-08 6.45E-10 6.61E-10 5.44E-10 2.18E-08 2.18E-08 2.02E-08 1.82E-08 1.82E-08 1.73E-08 -1.00E-07 -1.00E-07 -1.00E-07 PASS PASS PASS 1.00E-07 1.00E-07 1.00E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 30 50 1/27/2011 2.55E-08 2.56E-08 2.41E-08 2.68E-08 2.61E-08 1.98E-08 1.92E-08 2.01E-08 1.98E-08 2.10E-08 1.03E-08 1.06E-08 24 hr Anneal 60 1/28/2011 2.57E-08 2.57E-08 2.41E-08 2.69E-08 2.61E-08 1.98E-08 1.92E-08 2.01E-08 1.98E-08 2.10E-08 1.04E-08 1.06E-08 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 2 @ +/-15V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.12. Plot of Positive Bias Current 2 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 31 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.12. Raw data for Positive Bias Current 2 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Bias Current 2 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 9.78E-09 1.23E-08 1.50E-08 1.78E-08 1842 1.17E-08 1.42E-08 1.74E-08 2.05E-08 1843 1.19E-08 1.47E-08 1.78E-08 2.10E-08 1844 1.14E-08 1.40E-08 1.70E-08 1.99E-08 1845 1.14E-08 1.40E-08 1.69E-08 2.00E-08 1846 1.08E-08 1.25E-08 1.42E-08 1.61E-08 1847 1.14E-08 1.31E-08 1.49E-08 1.66E-08 1848 1.15E-08 1.33E-08 1.50E-08 1.67E-08 1849 1.13E-08 1.29E-08 1.47E-08 1.64E-08 1850 1.27E-08 1.48E-08 1.68E-08 1.88E-08 1851 1.14E-08 1.14E-08 1.14E-08 1.14E-08 1852 1.20E-08 1.20E-08 1.19E-08 1.19E-08 Biased Statistics Average Biased 1.13E-08 1.38E-08 1.68E-08 1.98E-08 Std Dev Biased 8.54E-10 9.25E-10 1.08E-09 1.23E-09 Ps90%/90% (+KTL) Biased 1.36E-08 1.64E-08 1.98E-08 2.32E-08 Ps90%/90% (-KTL) Biased 8.91E-09 1.13E-08 1.38E-08 1.64E-08 Un-Biased Statistics Average Un-Biased 1.15E-08 1.33E-08 1.51E-08 1.69E-08 Std Dev Un-Biased 7.04E-10 8.79E-10 9.83E-10 1.06E-09 Ps90%/90% (+KTL) Un-Biased 1.35E-08 1.57E-08 1.78E-08 1.98E-08 Ps90%/90% (-KTL) Un-Biased 9.60E-09 1.09E-08 1.24E-08 1.40E-08 Specification MIN -3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 Status PASS PASS PASS PASS Specification MAX 3.00E-08 6.00E-08 7.50E-08 7.50E-08 Status PASS PASS PASS PASS 168 hr Anneal 70 2/4/2011 2.28E-08 2.64E-08 2.69E-08 2.59E-08 2.56E-08 1.86E-08 1.93E-08 1.94E-08 1.92E-08 2.20E-08 1.14E-08 1.19E-08 2.67E-08 1.55E-09 3.09E-08 2.24E-08 2.67E-08 1.49E-09 3.08E-08 2.26E-08 2.55E-08 1.58E-09 2.99E-08 2.12E-08 2.10E-08 2.10E-08 1.97E-08 1.47E-09 1.47E-09 1.32E-09 2.51E-08 2.50E-08 2.33E-08 1.70E-08 1.70E-08 1.61E-08 -1.00E-07 -1.00E-07 -1.00E-07 PASS PASS PASS 1.00E-07 1.00E-07 1.00E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 32 50 1/27/2011 2.41E-08 2.75E-08 2.81E-08 2.68E-08 2.68E-08 1.97E-08 2.06E-08 2.07E-08 2.06E-08 2.36E-08 1.14E-08 1.19E-08 24 hr Anneal 60 1/28/2011 2.43E-08 2.76E-08 2.82E-08 2.68E-08 2.68E-08 1.97E-08 2.06E-08 2.07E-08 2.05E-08 2.35E-08 1.14E-08 1.19E-08 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 3 @ +/-15V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.13. Plot of Positive Bias Current 3 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 33 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.13. Raw data for Positive Bias Current 3 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Bias Current 3 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 9.38E-09 1.17E-08 1.43E-08 1.71E-08 1842 1.09E-08 1.33E-08 1.62E-08 1.91E-08 1843 1.10E-08 1.36E-08 1.65E-08 1.94E-08 1844 1.11E-08 1.36E-08 1.65E-08 1.93E-08 1845 1.12E-08 1.36E-08 1.65E-08 1.93E-08 1846 1.04E-08 1.22E-08 1.38E-08 1.57E-08 1847 1.09E-08 1.27E-08 1.44E-08 1.60E-08 1848 1.17E-08 1.35E-08 1.52E-08 1.69E-08 1849 1.09E-08 1.26E-08 1.44E-08 1.61E-08 1850 1.21E-08 1.41E-08 1.60E-08 1.79E-08 1851 1.11E-08 1.11E-08 1.11E-08 1.11E-08 1852 1.05E-08 1.05E-08 1.05E-08 1.05E-08 Biased Statistics Average Biased 1.07E-08 1.32E-08 1.60E-08 1.88E-08 Std Dev Biased 7.53E-10 8.47E-10 9.39E-10 9.67E-10 Ps90%/90% (+KTL) Biased 1.28E-08 1.55E-08 1.86E-08 2.15E-08 Ps90%/90% (-KTL) Biased 8.65E-09 1.08E-08 1.34E-08 1.62E-08 Un-Biased Statistics Average Un-Biased 1.12E-08 1.31E-08 1.48E-08 1.65E-08 Std Dev Un-Biased 6.43E-10 7.50E-10 8.58E-10 8.88E-10 Ps90%/90% (+KTL) Un-Biased 1.30E-08 1.51E-08 1.71E-08 1.90E-08 Ps90%/90% (-KTL) Un-Biased 9.44E-09 1.10E-08 1.24E-08 1.41E-08 Specification MIN -3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 Status PASS PASS PASS PASS Specification MAX 3.00E-08 6.00E-08 7.50E-08 7.50E-08 Status PASS PASS PASS PASS 168 hr Anneal 70 2/4/2011 2.20E-08 2.45E-08 2.48E-08 2.49E-08 2.50E-08 1.82E-08 1.86E-08 1.97E-08 1.89E-08 2.09E-08 1.10E-08 1.05E-08 2.54E-08 1.16E-09 2.86E-08 2.22E-08 2.55E-08 1.14E-09 2.86E-08 2.23E-08 2.43E-08 1.28E-09 2.78E-08 2.08E-08 2.05E-08 2.05E-08 1.92E-08 1.18E-09 1.21E-09 1.07E-09 2.37E-08 2.38E-08 2.22E-08 1.73E-08 1.72E-08 1.63E-08 -1.00E-07 -1.00E-07 -1.00E-07 PASS PASS PASS 1.00E-07 1.00E-07 1.00E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 34 50 1/27/2011 2.33E-08 2.56E-08 2.60E-08 2.60E-08 2.60E-08 1.94E-08 1.97E-08 2.10E-08 2.01E-08 2.23E-08 1.11E-08 1.04E-08 24 hr Anneal 60 1/28/2011 2.35E-08 2.56E-08 2.60E-08 2.61E-08 2.61E-08 1.93E-08 1.98E-08 2.10E-08 2.00E-08 2.24E-08 1.11E-08 1.04E-08 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 4 @ +/-15V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.14. Plot of Positive Bias Current 4 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 35 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.14. Raw data for Positive Bias Current 4 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Bias Current 4 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.08E-08 1.36E-08 1.65E-08 1.97E-08 1842 1.12E-08 1.39E-08 1.68E-08 1.98E-08 1843 9.85E-09 1.25E-08 1.54E-08 1.84E-08 1844 1.17E-08 1.43E-08 1.74E-08 2.06E-08 1845 1.08E-08 1.34E-08 1.65E-08 1.96E-08 1846 1.15E-08 1.27E-08 1.45E-08 1.65E-08 1847 1.09E-08 1.27E-08 1.43E-08 1.61E-08 1848 1.13E-08 1.33E-08 1.51E-08 1.69E-08 1849 1.07E-08 1.26E-08 1.44E-08 1.62E-08 1850 1.18E-08 1.38E-08 1.57E-08 1.75E-08 1851 1.07E-08 1.06E-08 1.07E-08 1.06E-08 1852 1.15E-08 1.15E-08 1.15E-08 1.15E-08 Biased Statistics Average Biased 1.09E-08 1.35E-08 1.65E-08 1.96E-08 Std Dev Biased 6.80E-10 6.84E-10 7.31E-10 7.64E-10 Ps90%/90% (+KTL) Biased 1.27E-08 1.54E-08 1.85E-08 2.17E-08 Ps90%/90% (-KTL) Biased 9.01E-09 1.17E-08 1.45E-08 1.75E-08 Un-Biased Statistics Average Un-Biased 1.12E-08 1.30E-08 1.48E-08 1.67E-08 Std Dev Un-Biased 4.62E-10 5.19E-10 5.68E-10 5.93E-10 Ps90%/90% (+KTL) Un-Biased 1.25E-08 1.44E-08 1.64E-08 1.83E-08 Ps90%/90% (-KTL) Un-Biased 9.98E-09 1.16E-08 1.32E-08 1.50E-08 Specification MIN -3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 Status PASS PASS PASS PASS Specification MAX 3.00E-08 6.00E-08 7.50E-08 7.50E-08 Status PASS PASS PASS PASS 168 hr Anneal 70 2/4/2011 2.53E-08 2.53E-08 2.36E-08 2.65E-08 2.52E-08 1.91E-08 1.87E-08 1.95E-08 1.91E-08 2.04E-08 1.07E-08 1.15E-08 2.65E-08 8.98E-10 2.90E-08 2.41E-08 2.65E-08 8.76E-10 2.89E-08 2.41E-08 2.51E-08 1.04E-09 2.80E-08 2.23E-08 2.07E-08 2.07E-08 1.94E-08 7.15E-10 7.05E-10 6.65E-10 2.27E-08 2.27E-08 2.12E-08 1.88E-08 1.88E-08 1.75E-08 -1.00E-07 -1.00E-07 -1.00E-07 PASS PASS PASS 1.00E-07 1.00E-07 1.00E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 36 50 1/27/2011 2.66E-08 2.66E-08 2.51E-08 2.76E-08 2.67E-08 2.04E-08 2.00E-08 2.09E-08 2.04E-08 2.18E-08 1.06E-08 1.15E-08 24 hr Anneal 60 1/28/2011 2.67E-08 2.66E-08 2.51E-08 2.76E-08 2.66E-08 2.04E-08 2.01E-08 2.09E-08 2.05E-08 2.19E-08 1.06E-08 1.15E-08 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 1 @ +/-15V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.15. Plot of Negative Bias Current 1 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 37 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.15. Raw data for Negative Bias Current 1 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Bias Current 1 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.04E-08 1.30E-08 1.59E-08 1.88E-08 1842 1.07E-08 1.32E-08 1.61E-08 1.91E-08 1843 9.43E-09 1.20E-08 1.48E-08 1.77E-08 1844 1.14E-08 1.41E-08 1.70E-08 2.01E-08 1845 1.05E-08 1.31E-08 1.59E-08 1.90E-08 1846 1.13E-08 1.25E-08 1.42E-08 1.60E-08 1847 1.04E-08 1.21E-08 1.39E-08 1.55E-08 1848 1.09E-08 1.27E-08 1.44E-08 1.62E-08 1849 1.05E-08 1.22E-08 1.40E-08 1.58E-08 1850 1.14E-08 1.33E-08 1.51E-08 1.69E-08 1851 1.04E-08 1.04E-08 1.04E-08 1.04E-08 1852 1.06E-08 1.06E-08 1.06E-08 1.05E-08 Biased Statistics Average Biased 1.05E-08 1.31E-08 1.60E-08 1.89E-08 Std Dev Biased 7.22E-10 7.52E-10 8.00E-10 8.67E-10 Ps90%/90% (+KTL) Biased 1.25E-08 1.51E-08 1.82E-08 2.13E-08 Ps90%/90% (-KTL) Biased 8.52E-09 1.10E-08 1.38E-08 1.66E-08 Un-Biased Statistics Average Un-Biased 1.09E-08 1.26E-08 1.43E-08 1.61E-08 Std Dev Un-Biased 4.62E-10 4.71E-10 4.94E-10 5.12E-10 Ps90%/90% (+KTL) Un-Biased 1.22E-08 1.39E-08 1.57E-08 1.75E-08 Ps90%/90% (-KTL) Un-Biased 9.63E-09 1.13E-08 1.30E-08 1.47E-08 Specification MIN -3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 Status PASS PASS PASS PASS Specification MAX 3.00E-08 6.00E-08 7.50E-08 7.50E-08 Status PASS PASS PASS PASS 168 hr Anneal 70 2/4/2011 2.42E-08 2.44E-08 2.26E-08 2.58E-08 2.44E-08 1.86E-08 1.81E-08 1.88E-08 1.85E-08 1.97E-08 1.04E-08 1.06E-08 2.56E-08 9.76E-10 2.83E-08 2.29E-08 2.57E-08 9.79E-10 2.83E-08 2.30E-08 2.43E-08 1.13E-09 2.74E-08 2.12E-08 2.00E-08 2.00E-08 1.88E-08 5.79E-10 5.83E-10 5.85E-10 2.16E-08 2.16E-08 2.04E-08 1.84E-08 1.84E-08 1.71E-08 -1.00E-07 -1.00E-07 -1.00E-07 PASS PASS PASS 1.00E-07 1.00E-07 1.00E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 38 50 1/27/2011 2.55E-08 2.55E-08 2.43E-08 2.70E-08 2.58E-08 1.98E-08 1.95E-08 2.02E-08 1.98E-08 2.10E-08 1.04E-08 1.06E-08 24 hr Anneal 60 1/28/2011 2.56E-08 2.56E-08 2.43E-08 2.70E-08 2.57E-08 1.97E-08 1.94E-08 2.02E-08 1.97E-08 2.09E-08 1.04E-08 1.06E-08 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 2 @ +/-15V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.16. Plot of Negative Bias Current 2 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 39 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.16. Raw data for Negative Bias Current 2 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Bias Current 2 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 9.71E-09 1.21E-08 1.48E-08 1.77E-08 1842 1.16E-08 1.41E-08 1.72E-08 2.03E-08 1843 1.19E-08 1.47E-08 1.77E-08 2.09E-08 1844 1.13E-08 1.40E-08 1.69E-08 2.00E-08 1845 1.14E-08 1.39E-08 1.69E-08 1.99E-08 1846 1.08E-08 1.25E-08 1.43E-08 1.62E-08 1847 1.13E-08 1.32E-08 1.49E-08 1.68E-08 1848 1.14E-08 1.32E-08 1.49E-08 1.67E-08 1849 1.13E-08 1.29E-08 1.47E-08 1.65E-08 1850 1.25E-08 1.47E-08 1.67E-08 1.87E-08 1851 1.13E-08 1.12E-08 1.13E-08 1.12E-08 1852 1.18E-08 1.18E-08 1.17E-08 1.17E-08 Biased Statistics Average Biased 1.12E-08 1.38E-08 1.67E-08 1.97E-08 Std Dev Biased 8.58E-10 9.54E-10 1.10E-09 1.22E-09 Ps90%/90% (+KTL) Biased 1.35E-08 1.64E-08 1.97E-08 2.31E-08 Ps90%/90% (-KTL) Biased 8.83E-09 1.11E-08 1.37E-08 1.64E-08 Un-Biased Statistics Average Un-Biased 1.15E-08 1.33E-08 1.51E-08 1.70E-08 Std Dev Un-Biased 6.53E-10 8.23E-10 9.27E-10 9.96E-10 Ps90%/90% (+KTL) Un-Biased 1.33E-08 1.56E-08 1.76E-08 1.97E-08 Ps90%/90% (-KTL) Un-Biased 9.68E-09 1.11E-08 1.26E-08 1.42E-08 Specification MIN -3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 Status PASS PASS PASS PASS Specification MAX 3.00E-08 6.00E-08 7.50E-08 7.50E-08 Status PASS PASS PASS PASS 168 hr Anneal 70 2/4/2011 2.27E-08 2.62E-08 2.70E-08 2.58E-08 2.56E-08 1.87E-08 1.94E-08 1.94E-08 1.92E-08 2.18E-08 1.12E-08 1.17E-08 2.66E-08 1.55E-09 3.09E-08 2.23E-08 2.66E-08 1.50E-09 3.07E-08 2.25E-08 2.55E-08 1.62E-09 2.99E-08 2.10E-08 2.10E-08 2.10E-08 1.97E-08 1.31E-09 1.33E-09 1.21E-09 2.46E-08 2.46E-08 2.30E-08 1.74E-08 1.73E-08 1.64E-08 -1.00E-07 -1.00E-07 -1.00E-07 PASS PASS PASS 1.00E-07 1.00E-07 1.00E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 40 50 1/27/2011 2.39E-08 2.73E-08 2.80E-08 2.70E-08 2.67E-08 2.00E-08 2.08E-08 2.06E-08 2.04E-08 2.33E-08 1.12E-08 1.17E-08 24 hr Anneal 60 1/28/2011 2.41E-08 2.73E-08 2.80E-08 2.71E-08 2.67E-08 1.99E-08 2.07E-08 2.06E-08 2.04E-08 2.33E-08 1.13E-08 1.18E-08 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 3 @ +/-15V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.17. Plot of Negative Bias Current 3 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 41 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.17. Raw data for Negative Bias Current 3 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Bias Current 3 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 9.29E-09 1.17E-08 1.44E-08 1.72E-08 1842 1.09E-08 1.33E-08 1.63E-08 1.92E-08 1843 1.10E-08 1.36E-08 1.65E-08 1.95E-08 1844 1.10E-08 1.36E-08 1.64E-08 1.95E-08 1845 1.11E-08 1.35E-08 1.63E-08 1.93E-08 1846 1.03E-08 1.21E-08 1.39E-08 1.56E-08 1847 1.09E-08 1.27E-08 1.44E-08 1.61E-08 1848 1.16E-08 1.35E-08 1.53E-08 1.70E-08 1849 1.09E-08 1.27E-08 1.44E-08 1.61E-08 1850 1.20E-08 1.41E-08 1.59E-08 1.80E-08 1851 1.10E-08 1.09E-08 1.09E-08 1.09E-08 1852 1.06E-08 1.06E-08 1.06E-08 1.05E-08 Biased Statistics Average Biased 1.07E-08 1.31E-08 1.60E-08 1.89E-08 Std Dev Biased 7.66E-10 7.96E-10 8.89E-10 9.69E-10 Ps90%/90% (+KTL) Biased 1.28E-08 1.53E-08 1.84E-08 2.16E-08 Ps90%/90% (-KTL) Biased 8.56E-09 1.09E-08 1.35E-08 1.63E-08 Un-Biased Statistics Average Un-Biased 1.12E-08 1.30E-08 1.48E-08 1.66E-08 Std Dev Un-Biased 6.65E-10 7.56E-10 8.27E-10 9.32E-10 Ps90%/90% (+KTL) Un-Biased 1.30E-08 1.51E-08 1.70E-08 1.91E-08 Ps90%/90% (-KTL) Un-Biased 9.34E-09 1.09E-08 1.25E-08 1.40E-08 Specification MIN -3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 Status PASS PASS PASS PASS Specification MAX 3.00E-08 6.00E-08 7.50E-08 7.50E-08 Status PASS PASS PASS PASS 168 hr Anneal 70 2/4/2011 2.21E-08 2.47E-08 2.52E-08 2.50E-08 2.49E-08 1.81E-08 1.87E-08 1.97E-08 1.88E-08 2.10E-08 1.09E-08 1.05E-08 2.55E-08 1.17E-09 2.88E-08 2.23E-08 2.56E-08 1.15E-09 2.88E-08 2.25E-08 2.44E-08 1.28E-09 2.79E-08 2.09E-08 2.06E-08 2.05E-08 1.93E-08 1.19E-09 1.17E-09 1.14E-09 2.38E-08 2.37E-08 2.24E-08 1.73E-08 1.73E-08 1.62E-08 -1.00E-07 -1.00E-07 -1.00E-07 PASS PASS PASS 1.00E-07 1.00E-07 1.00E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 42 50 1/27/2011 2.34E-08 2.58E-08 2.61E-08 2.62E-08 2.60E-08 1.94E-08 2.00E-08 2.10E-08 2.00E-08 2.24E-08 1.09E-08 1.05E-08 24 hr Anneal 60 1/28/2011 2.36E-08 2.60E-08 2.62E-08 2.63E-08 2.60E-08 1.94E-08 1.99E-08 2.09E-08 2.00E-08 2.23E-08 1.09E-08 1.06E-08 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 4 @ +/-15V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.18. Plot of Negative Bias Current 4 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 43 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.18. Raw data for Negative Bias Current 4 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Bias Current 4 @ +/-15V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.07E-08 1.33E-08 1.63E-08 1.93E-08 1842 1.11E-08 1.37E-08 1.66E-08 1.97E-08 1843 9.78E-09 1.24E-08 1.54E-08 1.84E-08 1844 1.19E-08 1.46E-08 1.76E-08 2.07E-08 1845 1.07E-08 1.33E-08 1.64E-08 1.95E-08 1846 1.09E-08 1.27E-08 1.45E-08 1.64E-08 1847 1.08E-08 1.27E-08 1.44E-08 1.61E-08 1848 1.12E-08 1.30E-08 1.49E-08 1.66E-08 1849 1.06E-08 1.25E-08 1.43E-08 1.61E-08 1850 1.16E-08 1.36E-08 1.55E-08 1.74E-08 1851 1.06E-08 1.06E-08 1.06E-08 1.06E-08 1852 1.15E-08 1.15E-08 1.15E-08 1.15E-08 Biased Statistics Average Biased 1.08E-08 1.35E-08 1.65E-08 1.95E-08 Std Dev Biased 7.47E-10 7.71E-10 8.02E-10 8.43E-10 Ps90%/90% (+KTL) Biased 1.29E-08 1.56E-08 1.87E-08 2.18E-08 Ps90%/90% (-KTL) Biased 8.77E-09 1.14E-08 1.43E-08 1.72E-08 Un-Biased Statistics Average Un-Biased 1.10E-08 1.29E-08 1.47E-08 1.65E-08 Std Dev Un-Biased 3.95E-10 4.55E-10 4.80E-10 5.11E-10 Ps90%/90% (+KTL) Un-Biased 1.21E-08 1.41E-08 1.60E-08 1.79E-08 Ps90%/90% (-KTL) Un-Biased 9.97E-09 1.16E-08 1.34E-08 1.51E-08 Specification MIN -3.00E-08 -6.00E-08 -7.50E-08 -7.50E-08 Status PASS PASS PASS PASS Specification MAX 3.00E-08 6.00E-08 7.50E-08 7.50E-08 Status PASS PASS PASS PASS 168 hr Anneal 70 2/4/2011 2.49E-08 2.51E-08 2.36E-08 2.67E-08 2.50E-08 1.90E-08 1.89E-08 1.92E-08 1.90E-08 2.02E-08 1.06E-08 1.15E-08 2.64E-08 9.83E-10 2.91E-08 2.37E-08 2.65E-08 9.59E-10 2.92E-08 2.39E-08 2.51E-08 1.13E-09 2.82E-08 2.20E-08 2.06E-08 2.06E-08 1.93E-08 6.15E-10 6.01E-10 5.55E-10 2.23E-08 2.22E-08 2.08E-08 1.89E-08 1.89E-08 1.77E-08 -1.00E-07 -1.00E-07 -1.00E-07 PASS PASS PASS 1.00E-07 1.00E-07 1.00E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 44 50 1/27/2011 2.61E-08 2.63E-08 2.52E-08 2.79E-08 2.66E-08 2.04E-08 2.02E-08 2.06E-08 2.03E-08 2.17E-08 1.06E-08 1.15E-08 24 hr Anneal 60 1/28/2011 2.63E-08 2.65E-08 2.53E-08 2.80E-08 2.66E-08 2.03E-08 2.01E-08 2.05E-08 2.02E-08 2.16E-08 1.06E-08 1.14E-08 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio 1 (dB) 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.19. Plot of Common Mode Rejection Ratio 1 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 45 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.19. Raw data for Common Mode Rejection Ratio 1 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Common Mode Rejection Ratio 1 (dB) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.31E+02 1.32E+02 1.34E+02 1.36E+02 1842 1.17E+02 1.20E+02 1.21E+02 1.21E+02 1843 1.24E+02 1.32E+02 1.35E+02 1.38E+02 1844 1.18E+02 1.16E+02 1.16E+02 1.16E+02 1845 1.31E+02 1.34E+02 1.31E+02 1.30E+02 1846 1.26E+02 1.32E+02 1.41E+02 1.46E+02 1847 1.13E+02 1.12E+02 1.11E+02 1.11E+02 1848 1.35E+02 1.40E+02 1.31E+02 1.27E+02 1849 1.23E+02 1.20E+02 1.19E+02 1.18E+02 1850 1.34E+02 1.28E+02 1.24E+02 1.22E+02 1851 1.16E+02 1.17E+02 1.16E+02 1.16E+02 1852 1.18E+02 1.18E+02 1.18E+02 1.17E+02 Biased Statistics Average Biased 1.24E+02 1.27E+02 1.27E+02 1.28E+02 Std Dev Biased 6.98E+00 8.14E+00 8.61E+00 9.67E+00 Ps90%/90% (+KTL) Biased 1.43E+02 1.49E+02 1.51E+02 1.55E+02 Ps90%/90% (-KTL) Biased 1.05E+02 1.04E+02 1.04E+02 1.02E+02 Un-Biased Statistics Average Un-Biased 1.26E+02 1.26E+02 1.25E+02 1.25E+02 Std Dev Un-Biased 9.02E+00 1.06E+01 1.14E+01 1.32E+01 Ps90%/90% (+KTL) Un-Biased 1.51E+02 1.55E+02 1.56E+02 1.61E+02 Ps90%/90% (-KTL) Un-Biased 1.02E+02 9.71E+01 9.42E+01 8.87E+01 Specification MIN 9.70E+01 9.70E+01 9.70E+01 9.70E+01 Status PASS PASS PASS PASS 50 1/27/2011 1.48E+02 1.22E+02 1.69E+02 1.15E+02 1.29E+02 1.35E+02 1.10E+02 1.26E+02 1.16E+02 1.21E+02 1.16E+02 1.17E+02 24 hr Anneal 60 1/28/2011 1.37E+02 1.22E+02 1.63E+02 1.16E+02 1.29E+02 1.35E+02 1.10E+02 1.25E+02 1.17E+02 1.21E+02 1.16E+02 1.17E+02 168 hr Anneal 70 2/4/2011 1.22E+02 1.19E+02 1.36E+02 1.15E+02 1.34E+02 1.34E+02 1.11E+02 1.31E+02 1.18E+02 1.23E+02 1.17E+02 1.17E+02 1.37E+02 2.17E+01 1.96E+02 7.72E+01 1.33E+02 1.85E+01 1.84E+02 8.26E+01 1.25E+02 9.08E+00 1.50E+02 1.00E+02 1.22E+02 9.39E+00 1.47E+02 9.58E+01 9.40E+01 PASS 1.22E+02 9.37E+00 1.47E+02 9.59E+01 9.40E+01 PASS 1.24E+02 9.20E+00 1.49E+02 9.83E+01 9.40E+01 PASS An ISO 9001:2008 and DSCC Certified Company 46 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio 2 (dB) 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.20. Plot of Common Mode Rejection Ratio 2 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 47 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.20. Raw data for Common Mode Rejection Ratio 2 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Common Mode Rejection Ratio 2 (dB) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.13E+02 1.11E+02 1.11E+02 1.11E+02 1842 1.13E+02 1.12E+02 1.12E+02 1.11E+02 1843 1.10E+02 1.09E+02 1.09E+02 1.09E+02 1844 1.16E+02 1.14E+02 1.14E+02 1.14E+02 1845 1.10E+02 1.09E+02 1.09E+02 1.09E+02 1846 1.26E+02 1.21E+02 1.20E+02 1.19E+02 1847 1.13E+02 1.12E+02 1.11E+02 1.11E+02 1848 1.13E+02 1.12E+02 1.12E+02 1.11E+02 1849 1.13E+02 1.12E+02 1.12E+02 1.11E+02 1850 1.11E+02 1.10E+02 1.10E+02 1.10E+02 1851 1.28E+02 1.28E+02 1.28E+02 1.28E+02 1852 1.12E+02 1.12E+02 1.12E+02 1.12E+02 Biased Statistics Average Biased 1.13E+02 1.11E+02 1.11E+02 1.11E+02 Std Dev Biased 2.43E+00 2.06E+00 1.96E+00 1.90E+00 Ps90%/90% (+KTL) Biased 1.19E+02 1.17E+02 1.16E+02 1.16E+02 Ps90%/90% (-KTL) Biased 1.06E+02 1.05E+02 1.05E+02 1.06E+02 Un-Biased Statistics Average Un-Biased 1.15E+02 1.14E+02 1.13E+02 1.12E+02 Std Dev Un-Biased 6.01E+00 4.47E+00 3.83E+00 3.76E+00 Ps90%/90% (+KTL) Un-Biased 1.32E+02 1.26E+02 1.23E+02 1.23E+02 Ps90%/90% (-KTL) Un-Biased 9.87E+01 1.01E+02 1.02E+02 1.02E+02 Specification MIN 9.70E+01 9.70E+01 9.70E+01 9.70E+01 Status PASS PASS PASS PASS 50 1/27/2011 1.10E+02 1.11E+02 1.09E+02 1.13E+02 1.09E+02 1.17E+02 1.10E+02 1.11E+02 1.11E+02 1.09E+02 1.28E+02 1.12E+02 24 hr Anneal 60 1/28/2011 1.10E+02 1.11E+02 1.09E+02 1.13E+02 1.09E+02 1.17E+02 1.10E+02 1.11E+02 1.11E+02 1.09E+02 1.28E+02 1.12E+02 168 hr Anneal 70 2/4/2011 1.11E+02 1.12E+02 1.10E+02 1.14E+02 1.10E+02 1.20E+02 1.11E+02 1.12E+02 1.11E+02 1.10E+02 1.28E+02 1.12E+02 1.11E+02 1.90E+00 1.16E+02 1.05E+02 1.11E+02 1.87E+00 1.16E+02 1.05E+02 1.11E+02 1.87E+00 1.16E+02 1.06E+02 1.12E+02 3.20E+00 1.20E+02 1.03E+02 9.40E+01 PASS 1.12E+02 3.25E+00 1.21E+02 1.03E+02 9.40E+01 PASS 1.13E+02 4.12E+00 1.24E+02 1.02E+02 9.40E+01 PASS An ISO 9001:2008 and DSCC Certified Company 48 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio 3 (dB) 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.21. Plot of Common Mode Rejection Ratio 3 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 49 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.21. Raw data for Common Mode Rejection Ratio 3 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Common Mode Rejection Ratio 3 (dB) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.18E+02 1.25E+02 1.26E+02 1.27E+02 1842 1.20E+02 1.17E+02 1.17E+02 1.16E+02 1843 1.14E+02 1.12E+02 1.12E+02 1.12E+02 1844 1.11E+02 1.10E+02 1.10E+02 1.10E+02 1845 1.19E+02 1.16E+02 1.16E+02 1.15E+02 1846 1.58E+02 1.29E+02 1.25E+02 1.23E+02 1847 1.19E+02 1.17E+02 1.16E+02 1.15E+02 1848 1.28E+02 1.49E+02 1.37E+02 1.31E+02 1849 1.17E+02 1.15E+02 1.15E+02 1.14E+02 1850 1.20E+02 1.19E+02 1.17E+02 1.17E+02 1851 1.38E+02 1.37E+02 1.34E+02 1.34E+02 1852 1.20E+02 1.20E+02 1.20E+02 1.20E+02 Biased Statistics Average Biased 1.17E+02 1.16E+02 1.16E+02 1.16E+02 Std Dev Biased 3.77E+00 5.68E+00 6.19E+00 6.77E+00 Ps90%/90% (+KTL) Biased 1.27E+02 1.32E+02 1.33E+02 1.35E+02 Ps90%/90% (-KTL) Biased 1.06E+02 1.00E+02 9.90E+01 9.76E+01 Un-Biased Statistics Average Un-Biased 1.28E+02 1.26E+02 1.22E+02 1.20E+02 Std Dev Un-Biased 1.70E+01 1.39E+01 9.41E+00 7.16E+00 Ps90%/90% (+KTL) Un-Biased 1.75E+02 1.64E+02 1.48E+02 1.40E+02 Ps90%/90% (-KTL) Un-Biased 8.19E+01 8.75E+01 9.61E+01 1.00E+02 Specification MIN 9.70E+01 9.70E+01 9.70E+01 9.70E+01 Status PASS PASS PASS PASS 50 1/27/2011 1.30E+02 1.16E+02 1.12E+02 1.10E+02 1.15E+02 1.20E+02 1.14E+02 1.27E+02 1.13E+02 1.15E+02 1.35E+02 1.20E+02 24 hr Anneal 60 1/28/2011 1.29E+02 1.16E+02 1.12E+02 1.10E+02 1.15E+02 1.20E+02 1.14E+02 1.27E+02 1.14E+02 1.16E+02 1.35E+02 1.20E+02 168 hr Anneal 70 2/4/2011 1.26E+02 1.17E+02 1.13E+02 1.10E+02 1.16E+02 1.24E+02 1.16E+02 1.28E+02 1.14E+02 1.17E+02 1.35E+02 1.20E+02 1.17E+02 8.10E+00 1.39E+02 9.44E+01 1.16E+02 7.47E+00 1.37E+02 9.58E+01 1.16E+02 6.35E+00 1.34E+02 9.91E+01 1.18E+02 5.65E+00 1.34E+02 1.03E+02 9.40E+01 PASS 1.18E+02 5.52E+00 1.33E+02 1.03E+02 9.40E+01 PASS 1.20E+02 5.75E+00 1.35E+02 1.04E+02 9.40E+01 PASS An ISO 9001:2008 and DSCC Certified Company 50 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio 4 (dB) 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.22. Plot of Common Mode Rejection Ratio 4 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 51 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.22. Raw data for Common Mode Rejection Ratio 4 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Common Mode Rejection Ratio 4 (dB) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.23E+02 1.19E+02 1.18E+02 1.18E+02 1842 1.27E+02 1.49E+02 1.50E+02 1.43E+02 1843 1.29E+02 1.22E+02 1.22E+02 1.21E+02 1844 1.20E+02 1.17E+02 1.16E+02 1.16E+02 1845 1.21E+02 1.18E+02 1.17E+02 1.17E+02 1846 1.25E+02 1.22E+02 1.20E+02 1.19E+02 1847 1.26E+02 1.21E+02 1.20E+02 1.18E+02 1848 1.15E+02 1.14E+02 1.13E+02 1.13E+02 1849 1.20E+02 1.18E+02 1.17E+02 1.16E+02 1850 1.34E+02 1.26E+02 1.24E+02 1.22E+02 1851 1.19E+02 1.19E+02 1.19E+02 1.19E+02 1852 1.29E+02 1.29E+02 1.29E+02 1.28E+02 Biased Statistics Average Biased 1.24E+02 1.25E+02 1.25E+02 1.23E+02 Std Dev Biased 3.92E+00 1.37E+01 1.42E+01 1.13E+01 Ps90%/90% (+KTL) Biased 1.35E+02 1.63E+02 1.64E+02 1.54E+02 Ps90%/90% (-KTL) Biased 1.13E+02 8.73E+01 8.59E+01 9.23E+01 Un-Biased Statistics Average Un-Biased 1.24E+02 1.20E+02 1.19E+02 1.18E+02 Std Dev Un-Biased 7.14E+00 4.74E+00 4.10E+00 3.57E+00 Ps90%/90% (+KTL) Un-Biased 1.43E+02 1.33E+02 1.30E+02 1.28E+02 Ps90%/90% (-KTL) Un-Biased 1.04E+02 1.07E+02 1.08E+02 1.08E+02 Specification MIN 9.70E+01 9.70E+01 9.70E+01 9.70E+01 Status PASS PASS PASS PASS 50 1/27/2011 1.18E+02 1.35E+02 1.20E+02 1.16E+02 1.17E+02 1.18E+02 1.17E+02 1.12E+02 1.15E+02 1.21E+02 1.19E+02 1.29E+02 24 hr Anneal 60 1/28/2011 1.18E+02 1.36E+02 1.20E+02 1.16E+02 1.17E+02 1.18E+02 1.17E+02 1.12E+02 1.15E+02 1.20E+02 1.19E+02 1.28E+02 168 hr Anneal 70 2/4/2011 1.21E+02 1.40E+02 1.23E+02 1.17E+02 1.18E+02 1.19E+02 1.18E+02 1.13E+02 1.16E+02 1.26E+02 1.19E+02 1.28E+02 1.21E+02 7.75E+00 1.42E+02 9.99E+01 1.21E+02 8.48E+00 1.45E+02 9.82E+01 1.24E+02 9.32E+00 1.49E+02 9.83E+01 1.17E+02 3.24E+00 1.25E+02 1.08E+02 9.40E+01 PASS 1.16E+02 3.12E+00 1.25E+02 1.08E+02 9.40E+01 PASS 1.18E+02 4.83E+00 1.32E+02 1.05E+02 9.40E+01 PASS An ISO 9001:2008 and DSCC Certified Company 52 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio 1 (dB) 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.23. Plot of Power Supply Rejection Ratio 1 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 53 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.23. Raw data for Power Supply Rejection Ratio 1 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Power Supply Rejection Ratio 1 (dB) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.24E+02 1.24E+02 1.24E+02 1.24E+02 1842 1.23E+02 1.24E+02 1.25E+02 1.25E+02 1843 1.32E+02 1.34E+02 1.39E+02 1.38E+02 1844 1.36E+02 1.41E+02 1.42E+02 1.51E+02 1845 1.24E+02 1.26E+02 1.26E+02 1.27E+02 1846 1.32E+02 1.32E+02 1.33E+02 1.37E+02 1847 1.54E+02 1.48E+02 1.41E+02 1.40E+02 1848 1.21E+02 1.21E+02 1.22E+02 1.21E+02 1849 1.27E+02 1.28E+02 1.27E+02 1.29E+02 1850 1.32E+02 1.34E+02 1.34E+02 1.35E+02 1851 1.25E+02 1.25E+02 1.26E+02 1.26E+02 1852 1.27E+02 1.27E+02 1.26E+02 1.26E+02 Biased Statistics Average Biased 1.28E+02 1.30E+02 1.31E+02 1.33E+02 Std Dev Biased 5.68E+00 7.40E+00 8.60E+00 1.14E+01 Ps90%/90% (+KTL) Biased 1.43E+02 1.50E+02 1.55E+02 1.64E+02 Ps90%/90% (-KTL) Biased 1.12E+02 1.09E+02 1.08E+02 1.02E+02 Un-Biased Statistics Average Un-Biased 1.33E+02 1.33E+02 1.31E+02 1.32E+02 Std Dev Un-Biased 1.27E+01 9.81E+00 7.29E+00 7.34E+00 Ps90%/90% (+KTL) Un-Biased 1.68E+02 1.60E+02 1.51E+02 1.52E+02 Ps90%/90% (-KTL) Un-Biased 9.82E+01 1.06E+02 1.11E+02 1.12E+02 Specification MIN 1.00E+02 1.00E+02 9.80E+01 9.80E+01 Status PASS PASS PASS PASS 50 1/27/2011 1.24E+02 1.26E+02 1.44E+02 1.59E+02 1.27E+02 1.43E+02 1.36E+02 1.22E+02 1.30E+02 1.38E+02 1.27E+02 1.27E+02 24 hr Anneal 60 1/28/2011 1.24E+02 1.26E+02 1.48E+02 1.46E+02 1.27E+02 1.39E+02 1.37E+02 1.22E+02 1.29E+02 1.36E+02 1.26E+02 1.26E+02 168 hr Anneal 70 2/4/2011 1.21E+02 1.24E+02 1.37E+02 1.44E+02 1.24E+02 1.31E+02 1.67E+02 1.20E+02 1.27E+02 1.31E+02 1.26E+02 1.27E+02 1.36E+02 1.51E+01 1.78E+02 9.46E+01 1.34E+02 1.18E+01 1.67E+02 1.02E+02 1.30E+02 9.81E+00 1.57E+02 1.03E+02 1.34E+02 8.11E+00 1.56E+02 1.11E+02 9.40E+01 PASS 1.32E+02 6.94E+00 1.51E+02 1.13E+02 9.40E+01 PASS 1.35E+02 1.84E+01 1.86E+02 8.47E+01 9.40E+01 PASS An ISO 9001:2008 and DSCC Certified Company 54 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio 2 (dB) 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.24. Plot of Power Supply Rejection Ratio 2 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 55 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.24. Raw data for Power Supply Rejection Ratio 2 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Power Supply Rejection Ratio 2 (dB) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.36E+02 1.32E+02 1.30E+02 1.30E+02 1842 1.42E+02 1.64E+02 1.46E+02 1.41E+02 1843 1.28E+02 1.26E+02 1.25E+02 1.26E+02 1844 1.44E+02 1.36E+02 1.34E+02 1.33E+02 1845 1.26E+02 1.24E+02 1.23E+02 1.23E+02 1846 1.23E+02 1.24E+02 1.25E+02 1.25E+02 1847 1.28E+02 1.27E+02 1.27E+02 1.25E+02 1848 1.36E+02 1.40E+02 1.43E+02 1.51E+02 1849 1.24E+02 1.25E+02 1.26E+02 1.26E+02 1850 1.27E+02 1.26E+02 1.26E+02 1.26E+02 1851 1.20E+02 1.20E+02 1.21E+02 1.21E+02 1852 1.26E+02 1.26E+02 1.26E+02 1.26E+02 Biased Statistics Average Biased 1.35E+02 1.36E+02 1.32E+02 1.31E+02 Std Dev Biased 8.30E+00 1.63E+01 8.87E+00 6.82E+00 Ps90%/90% (+KTL) Biased 1.58E+02 1.81E+02 1.56E+02 1.49E+02 Ps90%/90% (-KTL) Biased 1.12E+02 9.18E+01 1.07E+02 1.12E+02 Un-Biased Statistics Average Un-Biased 1.28E+02 1.29E+02 1.29E+02 1.31E+02 Std Dev Un-Biased 5.20E+00 6.44E+00 7.61E+00 1.13E+01 Ps90%/90% (+KTL) Un-Biased 1.42E+02 1.46E+02 1.50E+02 1.61E+02 Ps90%/90% (-KTL) Un-Biased 1.14E+02 1.11E+02 1.08E+02 9.97E+01 Specification MIN 1.00E+02 1.00E+02 9.80E+01 9.80E+01 Status PASS PASS PASS PASS 50 1/27/2011 1.29E+02 1.44E+02 1.25E+02 1.31E+02 1.23E+02 1.25E+02 1.25E+02 1.45E+02 1.27E+02 1.25E+02 1.21E+02 1.26E+02 24 hr Anneal 60 1/28/2011 1.28E+02 1.45E+02 1.25E+02 1.31E+02 1.23E+02 1.26E+02 1.25E+02 1.55E+02 1.27E+02 1.25E+02 1.21E+02 1.25E+02 168 hr Anneal 70 2/4/2011 1.32E+02 1.43E+02 1.27E+02 1.31E+02 1.24E+02 1.25E+02 1.26E+02 1.36E+02 1.26E+02 1.27E+02 1.21E+02 1.25E+02 1.30E+02 8.35E+00 1.53E+02 1.07E+02 1.30E+02 8.57E+00 1.54E+02 1.07E+02 1.32E+02 7.06E+00 1.51E+02 1.12E+02 1.29E+02 8.82E+00 1.54E+02 1.05E+02 9.40E+01 PASS 1.31E+02 1.31E+01 1.67E+02 9.54E+01 9.40E+01 PASS 1.28E+02 4.48E+00 1.40E+02 1.16E+02 9.40E+01 PASS An ISO 9001:2008 and DSCC Certified Company 56 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio 3 (dB) 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.25. Plot of Power Supply Rejection Ratio 3 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 57 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.25. Raw data for Power Supply Rejection Ratio 3 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Power Supply Rejection Ratio 3 (dB) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.19E+02 1.20E+02 1.20E+02 1.21E+02 1842 1.22E+02 1.24E+02 1.24E+02 1.24E+02 1843 1.27E+02 1.28E+02 1.30E+02 1.29E+02 1844 1.31E+02 1.29E+02 1.29E+02 1.28E+02 1845 1.30E+02 1.33E+02 1.33E+02 1.34E+02 1846 1.22E+02 1.22E+02 1.23E+02 1.23E+02 1847 1.29E+02 1.29E+02 1.31E+02 1.31E+02 1848 1.24E+02 1.25E+02 1.26E+02 1.26E+02 1849 1.31E+02 1.34E+02 1.35E+02 1.35E+02 1850 1.46E+02 1.45E+02 1.38E+02 1.37E+02 1851 1.31E+02 1.33E+02 1.34E+02 1.34E+02 1852 1.28E+02 1.28E+02 1.27E+02 1.28E+02 Biased Statistics Average Biased 1.26E+02 1.27E+02 1.27E+02 1.27E+02 Std Dev Biased 5.14E+00 4.87E+00 4.94E+00 5.22E+00 Ps90%/90% (+KTL) Biased 1.40E+02 1.40E+02 1.41E+02 1.41E+02 Ps90%/90% (-KTL) Biased 1.12E+02 1.13E+02 1.14E+02 1.13E+02 Un-Biased Statistics Average Un-Biased 1.30E+02 1.31E+02 1.31E+02 1.31E+02 Std Dev Un-Biased 9.57E+00 8.93E+00 6.32E+00 5.84E+00 Ps90%/90% (+KTL) Un-Biased 1.57E+02 1.55E+02 1.48E+02 1.47E+02 Ps90%/90% (-KTL) Un-Biased 1.04E+02 1.06E+02 1.13E+02 1.15E+02 Specification MIN 1.00E+02 1.00E+02 9.80E+01 9.80E+01 Status PASS PASS PASS PASS 50 1/27/2011 1.21E+02 1.24E+02 1.30E+02 1.28E+02 1.35E+02 1.24E+02 1.33E+02 1.28E+02 1.40E+02 1.34E+02 1.32E+02 1.27E+02 24 hr Anneal 60 1/28/2011 1.21E+02 1.25E+02 1.31E+02 1.28E+02 1.35E+02 1.23E+02 1.34E+02 1.27E+02 1.38E+02 1.33E+02 1.32E+02 1.28E+02 168 hr Anneal 70 2/4/2011 1.20E+02 1.22E+02 1.28E+02 1.30E+02 1.31E+02 1.23E+02 1.31E+02 1.26E+02 1.32E+02 1.43E+02 1.34E+02 1.28E+02 1.28E+02 5.16E+00 1.42E+02 1.13E+02 1.28E+02 5.63E+00 1.43E+02 1.13E+02 1.26E+02 4.88E+00 1.39E+02 1.13E+02 1.32E+02 6.19E+00 1.49E+02 1.15E+02 9.40E+01 PASS 1.31E+02 5.77E+00 1.47E+02 1.15E+02 9.40E+01 PASS 1.31E+02 7.74E+00 1.52E+02 1.10E+02 9.40E+01 PASS An ISO 9001:2008 and DSCC Certified Company 58 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio 4 (dB) 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.26. Plot of Power Supply Rejection Ratio 4 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 59 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.26. Raw data for Power Supply Rejection Ratio 4 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Power Supply Rejection Ratio 4 (dB) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.30E+02 1.28E+02 1.28E+02 1.27E+02 1842 1.28E+02 1.29E+02 1.30E+02 1.30E+02 1843 1.16E+02 1.17E+02 1.16E+02 1.17E+02 1844 1.34E+02 1.33E+02 1.31E+02 1.31E+02 1845 1.22E+02 1.23E+02 1.23E+02 1.24E+02 1846 1.20E+02 1.20E+02 1.20E+02 1.20E+02 1847 1.30E+02 1.33E+02 1.32E+02 1.37E+02 1848 1.46E+02 1.39E+02 1.38E+02 1.36E+02 1849 1.29E+02 1.30E+02 1.31E+02 1.32E+02 1850 1.70E+02 1.67E+02 1.57E+02 1.42E+02 1851 1.26E+02 1.26E+02 1.26E+02 1.26E+02 1852 1.22E+02 1.22E+02 1.22E+02 1.22E+02 Biased Statistics Average Biased 1.26E+02 1.26E+02 1.26E+02 1.26E+02 Std Dev Biased 7.16E+00 6.19E+00 5.95E+00 5.86E+00 Ps90%/90% (+KTL) Biased 1.46E+02 1.43E+02 1.42E+02 1.42E+02 Ps90%/90% (-KTL) Biased 1.06E+02 1.09E+02 1.09E+02 1.10E+02 Un-Biased Statistics Average Un-Biased 1.39E+02 1.38E+02 1.35E+02 1.33E+02 Std Dev Un-Biased 1.96E+01 1.77E+01 1.35E+01 8.09E+00 Ps90%/90% (+KTL) Un-Biased 1.93E+02 1.86E+02 1.72E+02 1.56E+02 Ps90%/90% (-KTL) Un-Biased 8.52E+01 8.91E+01 9.84E+01 1.11E+02 Specification MIN 1.00E+02 1.00E+02 9.80E+01 9.80E+01 Status PASS PASS PASS PASS 50 1/27/2011 1.28E+02 1.32E+02 1.17E+02 1.31E+02 1.24E+02 1.21E+02 1.43E+02 1.33E+02 1.34E+02 1.35E+02 1.26E+02 1.22E+02 24 hr Anneal 60 1/28/2011 1.27E+02 1.32E+02 1.17E+02 1.29E+02 1.24E+02 1.21E+02 1.46E+02 1.34E+02 1.33E+02 1.34E+02 1.27E+02 1.22E+02 168 hr Anneal 70 2/4/2011 1.28E+02 1.31E+02 1.17E+02 1.31E+02 1.23E+02 1.21E+02 1.38E+02 1.41E+02 1.33E+02 1.51E+02 1.26E+02 1.22E+02 1.26E+02 6.00E+00 1.43E+02 1.10E+02 1.26E+02 5.97E+00 1.42E+02 1.09E+02 1.26E+02 6.29E+00 1.43E+02 1.09E+02 1.33E+02 8.16E+00 1.56E+02 1.11E+02 9.40E+01 PASS 1.33E+02 8.89E+00 1.58E+02 1.09E+02 9.40E+01 PASS 1.37E+02 1.09E+01 1.67E+02 1.07E+02 9.40E+01 PASS An ISO 9001:2008 and DSCC Certified Company 60 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) 2.00E+05 1.00E+05 0.00E+00 -1.00E+05 -2.00E+05 -3.00E+05 -4.00E+05 -5.00E+05 0 10 20 30 40 Total Dose (krad(Si)) 50 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.27. Plot of Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 61 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.27. Raw data for Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) Device Date 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 10/20/2011 3.95E+04 7.57E+04 3.15E+04 1.09E+04 1.29E+05 7.92E+04 1.21E+04 5.00E+05 4.57E+04 4.50E+04 1.95E+04 2.16E+04 Total Dose (krad(Si)) 10 20 30 12/12/2011 12/23/2011 1/3/2011 1.02E+05 4.20E+04 2.31E+04 7.75E+04 7.47E+04 2.62E+04 2.63E+04 7.07E+04 8.98E+04 1.23E+04 7.73E+03 6.42E+03 2.28E+05 3.35E+04 1.79E+04 2.26E+05 1.09E+05 6.19E+04 1.26E+04 8.97E+03 8.71E+03 9.14E+04 3.02E+04 2.86E+04 8.33E+04 2.68E+05 5.77E+04 3.09E+04 2.36E+04 1.32E+04 1.79E+04 1.99E+04 2.08E+04 2.36E+04 2.42E+04 2.03E+04 50 1/27/2011 8.46E+03 1.01E+04 1.45E+04 4.44E+03 9.52E+03 1.81E+04 5.47E+03 9.45E+03 2.55E+04 9.80E+03 2.04E+04 2.21E+04 24 hr Anneal 60 1/28/2011 9.79E+03 1.02E+04 1.52E+04 4.16E+03 9.00E+03 3.11E+04 6.36E+03 1.35E+04 1.50E+04 9.69E+03 2.07E+04 2.22E+04 168 hr Anneal 70 2/4/2011 7.32E+03 9.06E+03 1.31E+04 3.91E+03 7.34E+03 1.92E+04 6.91E+03 2.01E+04 2.40E+04 1.04E+04 1.80E+04 2.28E+04 5.72E+04 8.93E+04 4.57E+04 4.63E+04 8.57E+04 2.77E+04 1.84E+05 3.24E+05 1.22E+05 -6.96E+04 -1.46E+05 -3.02E+04 3.27E+04 3.28E+04 1.23E+05 -5.73E+04 9.40E+03 3.60E+03 1.93E+04 -4.82E+02 9.68E+03 3.94E+03 2.05E+04 -1.13E+03 8.15E+03 3.36E+03 1.74E+04 -1.05E+03 1.36E+05 8.89E+04 8.81E+04 2.05E+05 8.38E+04 1.08E+05 6.98E+05 3.19E+05 3.84E+05 -4.25E+05 -1.41E+05 -2.08E+05 1.20E+03 5.00E+02 2.00E+02 PASS PASS PASS 3.40E+04 2.47E+04 1.02E+05 -3.37E+04 2.00E+02 PASS 1.37E+04 8.04E+03 3.57E+04 -8.39E+03 1.00E+02 PASS 1.51E+04 9.53E+03 4.13E+04 -1.10E+04 1.00E+02 PASS 1.61E+04 7.17E+03 3.58E+04 -3.53E+03 1.20E+03 PASS An ISO 9001:2008 and DSCC Certified Company 62 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) 2.00E+05 1.00E+05 0.00E+00 -1.00E+05 -2.00E+05 -3.00E+05 -4.00E+05 -5.00E+05 -6.00E+05 -7.00E+05 -8.00E+05 0 10 20 30 40 Total Dose (krad(Si)) 50 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.28. Plot of Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 63 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.28. Raw data for Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) Device Date 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 10/20/2011 2.82E+04 3.15E+04 1.21E+04 9.42E+03 9.92E+03 6.31E+04 1.85E+04 8.77E+03 1.33E+04 1.83E+04 7.09E+04 3.32E+04 Total Dose (krad(Si)) 10 20 30 12/12/2011 12/23/2011 1/3/2011 2.96E+04 6.66E+05 5.14E+04 2.28E+04 1.51E+04 1.10E+04 1.65E+04 9.68E+03 7.37E+03 1.07E+04 7.09E+03 5.62E+03 9.24E+03 8.15E+03 5.95E+03 4.55E+04 2.30E+04 1.76E+04 2.06E+04 1.38E+04 1.17E+04 8.37E+03 7.66E+03 6.64E+03 1.32E+04 1.12E+04 8.01E+03 1.56E+04 1.41E+04 9.99E+03 5.04E+04 3.71E+04 3.35E+04 3.67E+04 3.19E+04 3.64E+04 50 1/27/2011 1.79E+04 6.99E+03 4.38E+03 4.10E+03 4.43E+03 1.01E+04 6.51E+03 4.87E+03 8.23E+03 8.68E+03 4.36E+04 3.07E+04 24 hr Anneal 60 1/28/2011 1.62E+04 6.73E+03 4.65E+03 4.03E+03 4.27E+03 1.21E+04 7.02E+03 4.73E+03 6.50E+03 6.92E+03 4.22E+04 2.79E+04 168 hr Anneal 70 2/4/2011 1.37E+04 6.21E+03 4.21E+03 3.58E+03 4.09E+03 1.23E+04 7.45E+03 5.68E+03 7.61E+03 8.11E+03 5.32E+04 3.16E+04 1.82E+04 1.78E+04 1.41E+05 1.07E+04 8.51E+03 2.94E+05 4.76E+04 4.11E+04 9.46E+05 -1.12E+04 -5.56E+03 -6.64E+05 1.63E+04 1.97E+04 7.04E+04 -3.79E+04 7.57E+03 5.92E+03 2.38E+04 -8.65E+03 7.17E+03 5.15E+03 2.13E+04 -6.95E+03 6.36E+03 4.23E+03 1.80E+04 -5.23E+03 2.44E+04 2.07E+04 1.40E+04 2.20E+04 1.46E+04 5.70E+03 8.48E+04 6.06E+04 2.96E+04 -3.60E+04 -1.93E+04 -1.66E+03 1.20E+03 5.00E+02 2.00E+02 PASS PASS PASS 1.08E+04 4.25E+03 2.24E+04 -8.88E+02 2.00E+02 PASS 7.68E+03 2.03E+03 1.33E+04 2.11E+03 1.00E+02 PASS 7.46E+03 2.78E+03 1.51E+04 -1.52E+02 1.00E+02 PASS 8.22E+03 2.44E+03 1.49E+04 1.52E+03 1.20E+03 PASS An ISO 9001:2008 and DSCC Certified Company 64 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) 1.00E+05 5.00E+04 0.00E+00 -5.00E+04 -1.00E+05 -1.50E+05 -2.00E+05 0 10 20 30 40 Total Dose (krad(Si)) 50 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.29. Plot of Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 65 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.29. Raw data for Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) Device Date 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 10/20/2011 2.98E+04 1.94E+04 8.78E+03 9.73E+03 1.05E+04 6.27E+04 1.87E+04 1.43E+04 1.58E+04 2.24E+04 5.78E+04 1.94E+04 Total Dose (krad(Si)) 10 20 30 12/12/2011 12/23/2011 1/3/2011 3.67E+04 1.97E+05 6.35E+04 1.55E+04 1.18E+04 9.05E+03 1.03E+04 7.37E+03 5.93E+03 8.47E+03 7.16E+03 5.69E+03 1.18E+04 7.92E+03 6.00E+03 2.56E+04 1.99E+04 1.78E+04 1.54E+04 1.27E+04 1.23E+04 1.41E+04 9.52E+03 1.09E+04 1.60E+04 9.39E+03 9.79E+03 1.89E+04 1.39E+04 1.17E+04 6.74E+04 5.34E+04 4.10E+04 1.59E+04 1.92E+04 1.55E+04 50 1/27/2011 1.62E+04 5.55E+03 4.06E+03 3.84E+03 4.50E+03 8.48E+03 8.47E+03 7.53E+03 8.27E+03 7.94E+03 4.34E+04 1.65E+04 24 hr Anneal 60 1/28/2011 1.50E+04 5.11E+03 4.17E+03 3.73E+03 4.64E+03 1.00E+04 7.28E+03 7.08E+03 7.04E+03 8.13E+03 4.08E+04 1.76E+04 168 hr Anneal 70 2/4/2011 1.13E+04 4.99E+03 3.84E+03 3.40E+03 4.00E+03 1.11E+04 8.74E+03 6.47E+03 7.45E+03 8.95E+03 3.09E+04 1.76E+04 1.56E+04 1.65E+04 4.62E+04 9.00E+03 1.15E+04 8.41E+04 4.03E+04 4.82E+04 2.77E+05 -9.03E+03 -1.51E+04 -1.84E+05 1.80E+04 2.54E+04 8.78E+04 -5.17E+04 6.84E+03 5.29E+03 2.14E+04 -7.68E+03 6.53E+03 4.76E+03 1.96E+04 -6.51E+03 5.51E+03 3.29E+03 1.45E+04 -3.53E+03 2.68E+04 1.80E+04 1.31E+04 2.03E+04 4.61E+03 4.31E+03 8.25E+04 3.06E+04 2.49E+04 -2.89E+04 5.37E+03 1.26E+03 1.20E+03 5.00E+02 2.00E+02 PASS PASS PASS 1.25E+04 3.09E+03 2.10E+04 4.02E+03 2.00E+02 PASS 8.14E+03 4.05E+02 9.25E+03 7.03E+03 1.00E+02 PASS 7.90E+03 1.25E+03 1.13E+04 4.47E+03 1.00E+02 PASS 8.54E+03 1.73E+03 1.33E+04 3.79E+03 1.20E+03 PASS An ISO 9001:2008 and DSCC Certified Company 66 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) 4.00E+05 2.00E+05 0.00E+00 -2.00E+05 -4.00E+05 -6.00E+05 -8.00E+05 -1.00E+06 -1.20E+06 0 10 20 30 40 Total Dose (krad(Si)) 50 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.30. Plot of Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 67 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.30. Raw data for Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) Device Date 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 10/20/2011 3.72E+04 6.99E+04 4.19E+04 1.50E+04 2.69E+05 2.13E+05 1.54E+04 1.23E+05 5.97E+04 7.96E+04 1.86E+04 8.30E+04 Total Dose (krad(Si)) 10 20 30 12/12/2011 12/23/2011 1/3/2011 5.82E+04 1.63E+05 4.39E+04 4.27E+04 1.17E+05 2.80E+04 4.19E+04 1.33E+05 4.28E+04 1.53E+04 9.76E+03 7.54E+03 1.43E+05 3.74E+04 1.71E+04 2.07E+05 5.10E+04 2.55E+04 1.46E+04 1.31E+04 9.26E+03 2.32E+05 1.09E+05 2.66E+04 5.16E+04 1.03E+06 3.68E+04 7.11E+04 2.60E+04 1.83E+04 1.88E+04 2.17E+04 1.92E+04 6.93E+04 1.08E+05 5.41E+04 50 1/27/2011 1.26E+04 1.00E+04 1.32E+04 4.98E+03 1.06E+04 1.96E+04 8.88E+03 1.32E+04 3.02E+04 1.33E+04 1.92E+04 1.02E+05 24 hr Anneal 60 1/28/2011 1.45E+04 1.12E+04 1.31E+04 4.83E+03 8.99E+03 1.45E+04 7.98E+03 1.64E+04 2.35E+04 1.09E+04 1.87E+04 6.62E+04 168 hr Anneal 70 2/4/2011 1.59E+04 1.01E+04 1.15E+04 4.21E+03 8.53E+03 2.01E+04 7.37E+03 2.79E+04 3.20E+04 1.29E+04 1.97E+04 5.35E+04 8.65E+04 6.02E+04 9.20E+04 1.04E+05 4.87E+04 6.53E+04 3.71E+05 1.94E+05 2.71E+05 -1.98E+05 -7.35E+04 -8.72E+04 2.79E+04 1.59E+04 7.14E+04 -1.57E+04 1.03E+04 3.25E+03 1.92E+04 1.37E+03 1.05E+04 3.79E+03 2.09E+04 1.17E+02 1.00E+04 4.25E+03 2.17E+04 -1.61E+03 9.82E+04 1.15E+05 2.46E+05 7.50E+04 9.76E+04 4.40E+05 3.04E+05 3.83E+05 1.45E+06 -1.08E+05 -1.52E+05 -9.61E+05 1.20E+03 5.00E+02 2.00E+02 PASS PASS PASS 2.33E+04 1.03E+04 5.14E+04 -4.84E+03 2.00E+02 PASS 1.70E+04 8.31E+03 3.98E+04 -5.73E+03 1.00E+02 PASS 1.46E+04 5.93E+03 3.09E+04 -1.62E+03 1.00E+02 PASS 2.01E+04 1.02E+04 4.80E+04 -7.92E+03 1.20E+03 PASS An ISO 9001:2008 and DSCC Certified Company 68 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 1 @ +/-15V (V) 1.42E+01 1.40E+01 1.38E+01 1.36E+01 1.34E+01 1.32E+01 1.30E+01 1.28E+01 1.26E+01 1.24E+01 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.31. Plot of Positive Output Voltage 1 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 69 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.31. Raw data for Positive Output Voltage 1 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 1 @ +/-15V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1842 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1843 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1844 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1845 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1846 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1847 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1848 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1849 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1850 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1851 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1852 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Biased Statistics Average Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Std Dev Biased 5.67E-03 5.34E-03 4.95E-03 5.45E-03 Ps90%/90% (+KTL) Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Ps90%/90% (-KTL) Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Un-Biased Statistics Average Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Std Dev Un-Biased 6.86E-03 6.76E-03 7.29E-03 6.91E-03 Ps90%/90% (+KTL) Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Ps90%/90% (-KTL) Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Specification MIN 1.25E+01 1.25E+01 1.25E+01 1.25E+01 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 70 50 1/27/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 24 hr Anneal 60 1/28/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 168 hr Anneal 70 2/4/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 5.40E-03 5.36E-03 5.27E-03 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 6.91E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 7.26E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 6.86E-03 1.41E+01 1.41E+01 1.25E+01 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 2 @ +/-15V (V) 1.42E+01 1.40E+01 1.38E+01 1.36E+01 1.34E+01 1.32E+01 1.30E+01 1.28E+01 1.26E+01 1.24E+01 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.32. Plot of Positive Output Voltage 2 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 71 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.32. Raw data for Positive Output Voltage 2 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 2 @ +/-15V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1842 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1843 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1844 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1845 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1846 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1847 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1848 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1849 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1850 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1851 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1852 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Biased Statistics Average Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Std Dev Biased 3.39E-03 2.86E-03 3.27E-03 3.27E-03 Ps90%/90% (+KTL) Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Ps90%/90% (-KTL) Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Un-Biased Statistics Average Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Std Dev Un-Biased 2.70E-03 2.97E-03 2.79E-03 2.92E-03 Ps90%/90% (+KTL) Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Ps90%/90% (-KTL) Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Specification MIN 1.25E+01 1.25E+01 1.25E+01 1.25E+01 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 72 50 1/27/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 24 hr Anneal 60 1/28/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 168 hr Anneal 70 2/4/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 2.97E-03 3.13E-03 3.63E-03 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 3.03E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 3.00E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 2.70E-03 1.41E+01 1.41E+01 1.25E+01 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 3 @ +/-15V (V) 1.42E+01 1.40E+01 1.38E+01 1.36E+01 1.34E+01 1.32E+01 1.30E+01 1.28E+01 1.26E+01 1.24E+01 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.33. Plot of Positive Output Voltage 3 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 73 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.33. Raw data for Positive Output Voltage 3 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 3 @ +/-15V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1842 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1843 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1844 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1845 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1846 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1847 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1848 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1849 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1850 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1851 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1852 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Biased Statistics Average Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Std Dev Biased 3.91E-03 3.74E-03 3.35E-03 3.35E-03 Ps90%/90% (+KTL) Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Ps90%/90% (-KTL) Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Un-Biased Statistics Average Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Std Dev Un-Biased 2.97E-03 3.77E-03 3.27E-03 4.16E-03 Ps90%/90% (+KTL) Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Ps90%/90% (-KTL) Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Specification MIN 1.25E+01 1.25E+01 1.25E+01 1.25E+01 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 74 50 1/27/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 24 hr Anneal 60 1/28/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 168 hr Anneal 70 2/4/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 3.63E-03 3.63E-03 3.78E-03 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 3.74E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 3.74E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 3.11E-03 1.41E+01 1.41E+01 1.25E+01 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 4 @ +/-15V (V) 1.42E+01 1.40E+01 1.38E+01 1.36E+01 1.34E+01 1.32E+01 1.30E+01 1.28E+01 1.26E+01 1.24E+01 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.34. Plot of Positive Output Voltage 4 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 75 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.34. Raw data for Positive Output Voltage 4 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 4 @ +/-15V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1842 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1843 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1844 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1845 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1846 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1847 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1848 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1849 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1850 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1851 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1852 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Biased Statistics Average Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Std Dev Biased 4.92E-03 4.39E-03 4.39E-03 5.12E-03 Ps90%/90% (+KTL) Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Ps90%/90% (-KTL) Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Un-Biased Statistics Average Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Std Dev Un-Biased 6.42E-03 6.69E-03 6.87E-03 6.43E-03 Ps90%/90% (+KTL) Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Ps90%/90% (-KTL) Un-Biased 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Specification MIN 1.25E+01 1.25E+01 1.25E+01 1.25E+01 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 76 50 1/27/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 24 hr Anneal 60 1/28/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 168 hr Anneal 70 2/4/2011 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 4.39E-03 4.77E-03 5.18E-03 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 6.78E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 6.78E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 6.42E-03 1.41E+01 1.41E+01 1.25E+01 PASS ELDRS Report 11-573 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Output Voltage 1 @ +/-15V (V) -1.20E+01 -1.25E+01 -1.30E+01 -1.35E+01 -1.40E+01 -1.45E+01 -1.50E+01 0 10 20 30 40 Total Dose (krad(Si)) 50 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.35. Plot of Negative Output Voltage 1 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 77 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.35. Raw data for Negative Output Voltage 1 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Output Voltage 1 @ +/-15V (V) Device Date 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 10/20/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 Total Dose (krad(Si)) 10 20 30 12/12/2011 12/23/2011 1/3/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 50 1/27/2011 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 24 hr Anneal 60 1/28/2011 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 168 hr Anneal 70 2/4/2011 -1.45E+01 -1.44E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 4.82E-03 4.21E-03 4.04E-03 4.09E-03 3.56E-03 3.85E-03 3.74E-03 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 3.65E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.77E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.63E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.74E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 78 -1.45E+01 3.70E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.77E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.77E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS ELDRS Report 11-573 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Output Voltage 2 @ +/-15V (V) -1.20E+01 -1.25E+01 -1.30E+01 -1.35E+01 -1.40E+01 -1.45E+01 -1.50E+01 0 10 20 30 40 Total Dose (krad(Si)) 50 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.36. Plot of Negative Output Voltage 2 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 79 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.36. Raw data for Negative Output Voltage 2 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Output Voltage 2 @ +/-15V (V) Device Date 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 10/20/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 Total Dose (krad(Si)) 10 20 30 12/12/2011 12/23/2011 1/3/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 50 1/27/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 24 hr Anneal 60 1/28/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 168 hr Anneal 70 2/4/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 5.40E-03 4.92E-03 5.55E-03 4.92E-03 5.12E-03 4.69E-03 5.36E-03 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 4.34E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.96E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.45E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.83E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 80 -1.45E+01 4.71E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.06E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.06E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS ELDRS Report 11-573 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Output Voltage 3 @ +/-15V (V) -1.20E+01 -1.25E+01 -1.30E+01 -1.35E+01 -1.40E+01 -1.45E+01 -1.50E+01 0 10 20 30 40 Total Dose (krad(Si)) 50 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.37. Plot of Negative Output Voltage 3 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 81 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.37. Raw data for Negative Output Voltage 3 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Output Voltage 3 @ +/-15V (V) Device Date 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 10/20/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 Total Dose (krad(Si)) 10 20 30 12/12/2011 12/23/2011 1/3/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 50 1/27/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 24 hr Anneal 60 1/28/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 168 hr Anneal 70 2/4/2011 -1.45E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 5.55E-03 6.11E-03 5.55E-03 5.17E-03 5.41E-03 4.71E-03 5.55E-03 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 4.44E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.88E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.34E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.88E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 82 -1.45E+01 4.38E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.38E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.06E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS ELDRS Report 11-573 R1.0 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Output Voltage 4 @ +/-15V (V) -1.20E+01 -1.25E+01 -1.30E+01 -1.35E+01 -1.40E+01 -1.45E+01 -1.50E+01 0 10 20 30 40 Total Dose (krad(Si)) 50 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.38. Plot of Negative Output Voltage 4 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 83 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.38. Raw data for Negative Output Voltage 4 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Output Voltage 4 @ +/-15V (V) Device Date 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 10/20/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 Total Dose (krad(Si)) 10 20 30 12/12/2011 12/23/2011 1/3/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 50 1/27/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 24 hr Anneal 60 1/28/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 168 hr Anneal 70 2/4/2011 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 5.03E-03 4.44E-03 4.06E-03 3.71E-03 3.35E-03 3.65E-03 3.85E-03 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 3.61E-03 -1.45E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.70E-03 -1.45E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.63E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.74E-03 -1.45E+01 -1.45E+01 -1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 84 -1.45E+01 3.96E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 2.97E-03 -1.45E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.63E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Slew Rate 1 @ +/-15V (V/us) 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.39. Plot of Positive Slew Rate 1 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 85 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.39. Raw data for Positive Slew Rate 1 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Positive Slew Rate 1 @ +/-15V (V/us) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 4.92E-01 4.79E-01 4.73E-01 4.68E-01 4.62E-01 4.59E-01 4.58E-01 1842 4.64E-01 4.52E-01 4.57E-01 4.46E-01 4.30E-01 4.33E-01 4.31E-01 1843 4.88E-01 4.90E-01 4.74E-01 4.69E-01 4.53E-01 4.57E-01 4.54E-01 1844 4.44E-01 4.40E-01 4.29E-01 4.26E-01 4.08E-01 4.10E-01 4.14E-01 1845 4.81E-01 4.76E-01 4.76E-01 4.69E-01 4.57E-01 4.60E-01 4.51E-01 1846 4.89E-01 4.76E-01 4.72E-01 4.56E-01 4.52E-01 4.56E-01 4.59E-01 1847 4.63E-01 4.70E-01 4.55E-01 4.63E-01 4.46E-01 4.51E-01 4.50E-01 1848 4.61E-01 4.57E-01 4.44E-01 4.46E-01 4.38E-01 4.36E-01 4.39E-01 1849 4.86E-01 4.92E-01 4.78E-01 4.73E-01 4.62E-01 4.60E-01 4.79E-01 1850 4.76E-01 4.87E-01 4.72E-01 4.70E-01 4.51E-01 4.55E-01 4.60E-01 1851 4.68E-01 4.61E-01 4.67E-01 4.56E-01 4.61E-01 4.74E-01 4.57E-01 1852 4.84E-01 4.92E-01 4.83E-01 4.79E-01 4.74E-01 4.79E-01 4.74E-01 Biased Statistics Average Biased 4.74E-01 4.67E-01 4.62E-01 4.56E-01 4.42E-01 4.44E-01 4.42E-01 Std Dev Biased 1.98E-02 2.07E-02 1.98E-02 1.92E-02 2.26E-02 2.19E-02 1.86E-02 Ps90%/90% (+KTL) Biased 5.28E-01 5.24E-01 5.16E-01 5.08E-01 5.04E-01 5.04E-01 4.93E-01 Ps90%/90% (-KTL) Biased 4.19E-01 4.11E-01 4.07E-01 4.03E-01 3.80E-01 3.84E-01 3.91E-01 Un-Biased Statistics Average Un-Biased 4.75E-01 4.76E-01 4.64E-01 4.62E-01 4.50E-01 4.52E-01 4.57E-01 Std Dev Un-Biased 1.28E-02 1.39E-02 1.42E-02 1.09E-02 8.79E-03 9.29E-03 1.47E-02 Ps90%/90% (+KTL) Un-Biased 5.10E-01 5.15E-01 5.03E-01 4.92E-01 4.74E-01 4.77E-01 4.98E-01 Ps90%/90% (-KTL) Un-Biased 4.40E-01 4.38E-01 4.25E-01 4.32E-01 4.26E-01 4.26E-01 4.17E-01 Specification MIN 2.00E-01 1.30E-01 1.20E-01 1.20E-01 1.10E-01 1.10E-01 1.10E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 86 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Slew Rate 2 @ +/-15V (V/us) 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.40. Plot of Positive Slew Rate 2 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 87 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.40. Raw data for Positive Slew Rate 2 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Positive Slew Rate 2 @ +/-15V (V/us) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 5.32E-01 5.29E-01 5.10E-01 5.09E-01 4.84E-01 4.92E-01 4.91E-01 1842 4.89E-01 4.83E-01 4.70E-01 4.65E-01 4.49E-01 4.51E-01 4.55E-01 1843 4.81E-01 4.79E-01 4.71E-01 4.62E-01 4.65E-01 4.52E-01 4.55E-01 1844 4.72E-01 4.64E-01 4.60E-01 4.42E-01 4.41E-01 4.44E-01 4.36E-01 1845 4.69E-01 4.67E-01 4.68E-01 4.47E-01 4.33E-01 4.27E-01 4.40E-01 1846 5.25E-01 5.12E-01 5.04E-01 4.97E-01 4.96E-01 4.84E-01 4.97E-01 1847 4.64E-01 4.62E-01 4.63E-01 4.50E-01 4.45E-01 4.52E-01 4.51E-01 1848 4.67E-01 4.74E-01 4.71E-01 4.57E-01 4.53E-01 4.55E-01 4.58E-01 1849 4.92E-01 4.92E-01 4.86E-01 4.81E-01 4.61E-01 4.72E-01 4.79E-01 1850 5.06E-01 5.14E-01 5.02E-01 4.92E-01 4.82E-01 4.86E-01 4.93E-01 1851 4.94E-01 5.00E-01 4.99E-01 4.99E-01 4.94E-01 4.92E-01 4.94E-01 1852 4.78E-01 4.62E-01 4.75E-01 4.73E-01 4.67E-01 4.86E-01 4.81E-01 Biased Statistics Average Biased 4.89E-01 4.84E-01 4.76E-01 4.65E-01 4.54E-01 4.53E-01 4.55E-01 Std Dev Biased 2.55E-02 2.62E-02 1.96E-02 2.64E-02 2.03E-02 2.39E-02 2.17E-02 Ps90%/90% (+KTL) Biased 5.59E-01 5.56E-01 5.30E-01 5.38E-01 5.10E-01 5.19E-01 5.15E-01 Ps90%/90% (-KTL) Biased 4.19E-01 4.13E-01 4.22E-01 3.92E-01 3.99E-01 3.88E-01 3.96E-01 Un-Biased Statistics Average Un-Biased 4.91E-01 4.91E-01 4.85E-01 4.75E-01 4.67E-01 4.70E-01 4.76E-01 Std Dev Un-Biased 2.59E-02 2.29E-02 1.82E-02 2.10E-02 2.11E-02 1.58E-02 2.05E-02 Ps90%/90% (+KTL) Un-Biased 5.62E-01 5.54E-01 5.35E-01 5.33E-01 5.25E-01 5.13E-01 5.32E-01 Ps90%/90% (-KTL) Un-Biased 4.20E-01 4.28E-01 4.35E-01 4.18E-01 4.10E-01 4.26E-01 4.19E-01 Specification MIN 2.00E-01 1.30E-01 1.20E-01 1.20E-01 1.10E-01 1.10E-01 1.10E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 88 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased 5.00E-01 Positive Slew Rate 3 @ +/-15V (V/us) 4.50E-01 4.00E-01 3.50E-01 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.41. Plot of Positive Slew Rate 3 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 89 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.41. Raw data for Positive Slew Rate 3 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Positive Slew Rate 3 @ +/-15V (V/us) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 5.03E-01 4.93E-01 4.90E-01 4.81E-01 4.67E-01 4.66E-01 4.65E-01 1842 4.73E-01 4.54E-01 4.50E-01 4.49E-01 4.27E-01 4.30E-01 4.34E-01 1843 4.54E-01 4.53E-01 4.46E-01 4.37E-01 4.19E-01 4.28E-01 4.24E-01 1844 4.42E-01 4.42E-01 4.34E-01 4.31E-01 4.19E-01 4.17E-01 4.07E-01 1845 4.45E-01 4.41E-01 4.30E-01 4.26E-01 4.18E-01 4.15E-01 4.12E-01 1846 4.87E-01 4.81E-01 4.82E-01 4.72E-01 4.62E-01 4.59E-01 4.60E-01 1847 4.34E-01 4.44E-01 4.33E-01 4.31E-01 4.23E-01 4.20E-01 4.27E-01 1848 4.46E-01 4.49E-01 4.49E-01 4.35E-01 4.26E-01 4.28E-01 4.32E-01 1849 4.56E-01 4.67E-01 4.69E-01 4.52E-01 4.33E-01 4.37E-01 4.48E-01 1850 4.82E-01 4.71E-01 4.75E-01 4.57E-01 4.46E-01 4.59E-01 4.70E-01 1851 4.71E-01 4.69E-01 4.65E-01 4.64E-01 4.66E-01 4.63E-01 4.66E-01 1852 4.55E-01 4.51E-01 4.54E-01 4.53E-01 4.58E-01 4.52E-01 4.57E-01 Biased Statistics Average Biased 4.63E-01 4.57E-01 4.50E-01 4.45E-01 4.30E-01 4.31E-01 4.28E-01 Std Dev Biased 2.52E-02 2.12E-02 2.38E-02 2.20E-02 2.10E-02 2.05E-02 2.30E-02 Ps90%/90% (+KTL) Biased 5.33E-01 5.15E-01 5.15E-01 5.05E-01 4.88E-01 4.88E-01 4.91E-01 Ps90%/90% (-KTL) Biased 3.94E-01 3.98E-01 3.85E-01 3.85E-01 3.72E-01 3.75E-01 3.65E-01 Un-Biased Statistics Average Un-Biased 4.61E-01 4.62E-01 4.62E-01 4.49E-01 4.38E-01 4.41E-01 4.47E-01 Std Dev Un-Biased 2.29E-02 1.55E-02 2.02E-02 1.67E-02 1.61E-02 1.78E-02 1.82E-02 Ps90%/90% (+KTL) Un-Biased 5.24E-01 5.05E-01 5.17E-01 4.95E-01 4.82E-01 4.90E-01 4.97E-01 Ps90%/90% (-KTL) Un-Biased 3.98E-01 4.20E-01 4.06E-01 4.03E-01 3.94E-01 3.92E-01 3.98E-01 Specification MIN 2.00E-01 1.30E-01 1.20E-01 1.20E-01 1.10E-01 1.10E-01 1.10E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 90 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Slew Rate 4 @ +/-15V (V/us) 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.42. Plot of Positive Slew Rate 4 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 91 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.42. Raw data for Positive Slew Rate 4 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Positive Slew Rate 4 @ +/-15V (V/us) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 5.12E-01 5.03E-01 5.02E-01 5.03E-01 4.79E-01 4.82E-01 4.80E-01 1842 4.95E-01 4.92E-01 4.79E-01 4.64E-01 4.61E-01 4.49E-01 4.60E-01 1843 5.15E-01 5.12E-01 4.98E-01 4.94E-01 4.85E-01 4.76E-01 4.83E-01 1844 4.64E-01 4.57E-01 4.54E-01 4.51E-01 4.31E-01 4.37E-01 4.34E-01 1845 5.16E-01 5.06E-01 4.86E-01 4.86E-01 4.83E-01 4.85E-01 4.78E-01 1846 5.13E-01 5.11E-01 4.91E-01 4.85E-01 4.85E-01 4.89E-01 4.94E-01 1847 4.89E-01 5.00E-01 4.96E-01 4.88E-01 4.75E-01 4.66E-01 4.76E-01 1848 4.79E-01 4.84E-01 4.73E-01 4.63E-01 4.69E-01 4.55E-01 4.60E-01 1849 5.18E-01 5.15E-01 5.04E-01 4.97E-01 4.84E-01 4.90E-01 4.86E-01 1850 5.10E-01 5.01E-01 4.87E-01 4.88E-01 4.90E-01 4.86E-01 4.89E-01 1851 5.02E-01 4.95E-01 4.97E-01 4.88E-01 4.87E-01 4.86E-01 4.91E-01 1852 5.11E-01 5.17E-01 5.17E-01 5.02E-01 5.07E-01 4.97E-01 5.08E-01 Biased Statistics Average Biased 5.00E-01 4.94E-01 4.84E-01 4.80E-01 4.68E-01 4.66E-01 4.67E-01 Std Dev Biased 2.21E-02 2.19E-02 1.90E-02 2.15E-02 2.27E-02 2.15E-02 2.05E-02 Ps90%/90% (+KTL) Biased 5.61E-01 5.54E-01 5.36E-01 5.39E-01 5.30E-01 5.25E-01 5.23E-01 Ps90%/90% (-KTL) Biased 4.40E-01 4.34E-01 4.32E-01 4.21E-01 4.06E-01 4.07E-01 4.11E-01 Un-Biased Statistics Average Un-Biased 5.02E-01 5.02E-01 4.90E-01 4.84E-01 4.81E-01 4.77E-01 4.81E-01 Std Dev Un-Biased 1.69E-02 1.20E-02 1.15E-02 1.27E-02 8.44E-03 1.58E-02 1.35E-02 Ps90%/90% (+KTL) Un-Biased 5.48E-01 5.35E-01 5.22E-01 5.19E-01 5.04E-01 5.21E-01 5.18E-01 Ps90%/90% (-KTL) Un-Biased 4.56E-01 4.69E-01 4.59E-01 4.49E-01 4.57E-01 4.34E-01 4.44E-01 Specification MIN 2.00E-01 1.30E-01 1.20E-01 1.20E-01 1.10E-01 1.10E-01 1.10E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 92 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Negative Slew Rate 1 @ +/-15V (V/us) 0.00E+00 -1.00E-01 -2.00E-01 -3.00E-01 -4.00E-01 -5.00E-01 -6.00E-01 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.43. Plot of Negative Slew Rate 1 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 93 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.43. Raw data for Negative Slew Rate 1 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Slew Rate 1 @ +/-15V (V/us) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -5.40E-01 -5.31E-01 -5.36E-01 -5.29E-01 1842 -5.20E-01 -5.03E-01 -5.00E-01 -5.00E-01 1843 -5.38E-01 -5.41E-01 -5.39E-01 -5.36E-01 1844 -4.96E-01 -4.86E-01 -4.87E-01 -4.67E-01 1845 -5.34E-01 -5.36E-01 -5.30E-01 -5.26E-01 1846 -5.39E-01 -5.37E-01 -5.40E-01 -5.13E-01 1847 -5.25E-01 -5.34E-01 -5.13E-01 -4.92E-01 1848 -4.94E-01 -5.12E-01 -5.00E-01 -4.89E-01 1849 -5.33E-01 -5.48E-01 -5.25E-01 -5.15E-01 1850 -5.42E-01 -5.44E-01 -5.32E-01 -5.29E-01 1851 -4.97E-01 -5.09E-01 -5.24E-01 -5.16E-01 1852 -5.25E-01 -5.37E-01 -5.21E-01 -5.42E-01 Biased Statistics Average Biased -5.26E-01 -5.19E-01 -5.18E-01 -5.12E-01 Std Dev Biased 1.83E-02 2.38E-02 2.34E-02 2.84E-02 Ps90%/90% (+KTL) Biased -4.75E-01 -4.54E-01 -4.54E-01 -4.34E-01 Ps90%/90% (-KTL) Biased -5.76E-01 -5.85E-01 -5.83E-01 -5.90E-01 Un-Biased Statistics Average Un-Biased -5.27E-01 -5.35E-01 -5.22E-01 -5.08E-01 Std Dev Un-Biased 1.93E-02 1.40E-02 1.58E-02 1.68E-02 Ps90%/90% (+KTL) Un-Biased -4.74E-01 -4.97E-01 -4.79E-01 -4.61E-01 Ps90%/90% (-KTL) Un-Biased -5.80E-01 -5.73E-01 -5.65E-01 -5.54E-01 Specification MAX -2.00E-01 -1.30E-01 -1.20E-01 -1.20E-01 Status PASS PASS PASS PASS 50 1/27/2011 -5.01E-01 -4.74E-01 -5.06E-01 -4.62E-01 -4.97E-01 -5.00E-01 -4.98E-01 -4.77E-01 -5.10E-01 -5.28E-01 -5.06E-01 -5.28E-01 168 hr Anneal 70 2/4/2011 -5.09E-01 -4.70E-01 -5.07E-01 -4.67E-01 -5.12E-01 -5.10E-01 -5.03E-01 -4.94E-01 -5.22E-01 -5.17E-01 -5.20E-01 -5.40E-01 -4.88E-01 -4.94E-01 -4.93E-01 1.90E-02 2.24E-02 2.25E-02 -4.36E-01 -4.33E-01 -4.31E-01 -5.40E-01 -5.56E-01 -5.55E-01 -5.03E-01 1.86E-02 -4.52E-01 -5.54E-01 -1.10E-01 PASS An ISO 9001:2008 and DSCC Certified Company 94 24 hr Anneal 60 1/28/2011 -5.13E-01 -4.77E-01 -5.09E-01 -4.64E-01 -5.09E-01 -5.10E-01 -5.02E-01 -4.88E-01 -5.44E-01 -5.11E-01 -5.20E-01 -5.24E-01 -5.11E-01 2.06E-02 -4.54E-01 -5.68E-01 -1.10E-01 PASS -5.09E-01 1.11E-02 -4.79E-01 -5.40E-01 -1.10E-01 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Negative Slew Rate 2 @ +/-15V (V/us) 0.00E+00 -1.00E-01 -2.00E-01 -3.00E-01 -4.00E-01 -5.00E-01 -6.00E-01 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.44. Plot of Negative Slew Rate 2 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 95 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.44. Raw data for Negative Slew Rate 2 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Slew Rate 2 @ +/-15V (V/us) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -5.79E-01 -5.89E-01 -5.73E-01 -5.58E-01 1842 -5.45E-01 -5.29E-01 -5.32E-01 -5.22E-01 1843 -5.25E-01 -5.34E-01 -5.20E-01 -5.10E-01 1844 -5.32E-01 -5.19E-01 -5.14E-01 -4.92E-01 1845 -5.24E-01 -5.11E-01 -5.11E-01 -4.94E-01 1846 -5.68E-01 -5.71E-01 -5.62E-01 -5.55E-01 1847 -5.33E-01 -5.15E-01 -5.15E-01 -5.14E-01 1848 -5.19E-01 -5.26E-01 -5.10E-01 -5.11E-01 1849 -5.42E-01 -5.29E-01 -5.34E-01 -5.22E-01 1850 -5.69E-01 -5.67E-01 -5.62E-01 -5.61E-01 1851 -5.60E-01 -5.45E-01 -5.59E-01 -5.40E-01 1852 -5.41E-01 -5.30E-01 -5.27E-01 -5.26E-01 Biased Statistics Average Biased -5.41E-01 -5.36E-01 -5.30E-01 -5.15E-01 Std Dev Biased 2.28E-02 3.07E-02 2.53E-02 2.69E-02 Ps90%/90% (+KTL) Biased -4.78E-01 -4.52E-01 -4.60E-01 -4.41E-01 Ps90%/90% (-KTL) Biased -6.04E-01 -6.21E-01 -6.00E-01 -5.89E-01 Un-Biased Statistics Average Un-Biased -5.46E-01 -5.42E-01 -5.37E-01 -5.33E-01 Std Dev Un-Biased 2.19E-02 2.56E-02 2.49E-02 2.36E-02 Ps90%/90% (+KTL) Un-Biased -4.86E-01 -4.71E-01 -4.68E-01 -4.68E-01 Ps90%/90% (-KTL) Un-Biased -6.06E-01 -6.12E-01 -6.05E-01 -5.97E-01 Specification MAX -2.00E-01 -1.30E-01 -1.20E-01 -1.20E-01 Status PASS PASS PASS PASS 50 1/27/2011 -5.52E-01 -4.96E-01 -5.03E-01 -4.83E-01 -4.89E-01 -5.40E-01 -5.04E-01 -4.96E-01 -5.19E-01 -5.35E-01 -5.44E-01 -5.22E-01 168 hr Anneal 70 2/4/2011 -5.44E-01 -4.96E-01 -4.98E-01 -4.83E-01 -4.93E-01 -5.56E-01 -4.97E-01 -4.87E-01 -5.33E-01 -5.49E-01 -5.53E-01 -5.20E-01 -5.05E-01 -5.03E-01 -5.03E-01 2.75E-02 2.69E-02 2.37E-02 -4.29E-01 -4.29E-01 -4.38E-01 -5.80E-01 -5.77E-01 -5.68E-01 -5.19E-01 1.90E-02 -4.67E-01 -5.71E-01 -1.10E-01 PASS An ISO 9001:2008 and DSCC Certified Company 96 24 hr Anneal 60 1/28/2011 -5.48E-01 -5.00E-01 -5.03E-01 -4.86E-01 -4.79E-01 -5.49E-01 -4.92E-01 -4.96E-01 -5.17E-01 -5.40E-01 -5.50E-01 -5.34E-01 -5.19E-01 2.55E-02 -4.49E-01 -5.89E-01 -1.10E-01 PASS -5.24E-01 3.09E-02 -4.40E-01 -6.09E-01 -1.10E-01 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Negative Slew Rate 3 @ +/-15V (V/us) 0.00E+00 -1.00E-01 -2.00E-01 -3.00E-01 -4.00E-01 -5.00E-01 -6.00E-01 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.45. Plot of Negative Slew Rate 3 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 97 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.45. Raw data for Negative Slew Rate 3 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Slew Rate 3 @ +/-15V (V/us) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -5.63E-01 -5.60E-01 -5.38E-01 -5.33E-01 1842 -5.13E-01 -5.08E-01 -4.82E-01 -4.84E-01 1843 -4.93E-01 -4.96E-01 -4.94E-01 -4.84E-01 1844 -4.87E-01 -4.93E-01 -4.95E-01 -4.72E-01 1845 -4.93E-01 -4.89E-01 -4.79E-01 -4.68E-01 1846 -5.40E-01 -5.45E-01 -5.39E-01 -5.25E-01 1847 -4.90E-01 -4.95E-01 -4.79E-01 -4.79E-01 1848 -4.99E-01 -4.94E-01 -4.90E-01 -4.77E-01 1849 -5.09E-01 -5.04E-01 -5.00E-01 -4.92E-01 1850 -5.30E-01 -5.32E-01 -5.17E-01 -5.16E-01 1851 -5.24E-01 -5.16E-01 -5.02E-01 -5.10E-01 1852 -5.04E-01 -5.05E-01 -4.96E-01 -5.16E-01 Biased Statistics Average Biased -5.10E-01 -5.09E-01 -4.98E-01 -4.88E-01 Std Dev Biased 3.13E-02 2.93E-02 2.37E-02 2.60E-02 Ps90%/90% (+KTL) Biased -4.24E-01 -4.29E-01 -4.33E-01 -4.17E-01 Ps90%/90% (-KTL) Biased -5.96E-01 -5.89E-01 -5.63E-01 -5.60E-01 Un-Biased Statistics Average Un-Biased -5.14E-01 -5.14E-01 -5.05E-01 -4.98E-01 Std Dev Un-Biased 2.10E-02 2.32E-02 2.36E-02 2.17E-02 Ps90%/90% (+KTL) Un-Biased -4.56E-01 -4.50E-01 -4.40E-01 -4.38E-01 Ps90%/90% (-KTL) Un-Biased -5.71E-01 -5.78E-01 -5.70E-01 -5.57E-01 Specification MAX -2.00E-01 -1.30E-01 -1.20E-01 -1.20E-01 Status PASS PASS PASS PASS 50 1/27/2011 -5.23E-01 -4.72E-01 -4.77E-01 -4.64E-01 -4.58E-01 -5.08E-01 -4.64E-01 -4.69E-01 -4.90E-01 -5.19E-01 -5.15E-01 -5.10E-01 168 hr Anneal 70 2/4/2011 -5.25E-01 -4.72E-01 -4.68E-01 -4.54E-01 -4.53E-01 -5.23E-01 -4.84E-01 -4.80E-01 -4.94E-01 -5.35E-01 -5.16E-01 -5.05E-01 -4.79E-01 -4.77E-01 -4.74E-01 2.58E-02 2.67E-02 2.95E-02 -4.08E-01 -4.04E-01 -3.94E-01 -5.49E-01 -5.50E-01 -5.55E-01 -4.90E-01 2.39E-02 -4.25E-01 -5.55E-01 -1.10E-01 PASS An ISO 9001:2008 and DSCC Certified Company 98 24 hr Anneal 60 1/28/2011 -5.23E-01 -4.71E-01 -4.73E-01 -4.59E-01 -4.58E-01 -5.23E-01 -4.71E-01 -4.75E-01 -4.82E-01 -5.09E-01 -5.23E-01 -4.97E-01 -4.92E-01 2.28E-02 -4.29E-01 -5.55E-01 -1.10E-01 PASS -5.03E-01 2.45E-02 -4.36E-01 -5.70E-01 -1.10E-01 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Negative Slew Rate 4 @ +/-15V (V/us) 0.00E+00 -1.00E-01 -2.00E-01 -3.00E-01 -4.00E-01 -5.00E-01 -6.00E-01 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.46. Plot of Negative Slew Rate 4 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 99 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.46. Raw data for Negative Slew Rate 4 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Slew Rate 4 @ +/-15V (V/us) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -5.73E-01 -5.80E-01 -5.68E-01 -5.65E-01 1842 -5.36E-01 -5.29E-01 -5.27E-01 -5.17E-01 1843 -5.84E-01 -5.71E-01 -5.55E-01 -5.53E-01 1844 -5.19E-01 -5.30E-01 -5.09E-01 -4.90E-01 1845 -5.68E-01 -5.74E-01 -5.56E-01 -5.61E-01 1846 -5.66E-01 -5.61E-01 -5.48E-01 -5.42E-01 1847 -5.66E-01 -5.75E-01 -5.50E-01 -5.41E-01 1848 -5.24E-01 -5.43E-01 -5.30E-01 -5.18E-01 1849 -5.79E-01 -5.74E-01 -5.66E-01 -5.52E-01 1850 -5.60E-01 -5.66E-01 -5.52E-01 -5.58E-01 1851 -5.57E-01 -5.43E-01 -5.47E-01 -5.49E-01 1852 -5.62E-01 -5.64E-01 -5.63E-01 -5.67E-01 Biased Statistics Average Biased -5.56E-01 -5.57E-01 -5.43E-01 -5.37E-01 Std Dev Biased 2.73E-02 2.51E-02 2.42E-02 3.25E-02 Ps90%/90% (+KTL) Biased -4.81E-01 -4.88E-01 -4.77E-01 -4.48E-01 Ps90%/90% (-KTL) Biased -6.31E-01 -6.26E-01 -6.09E-01 -6.26E-01 Un-Biased Statistics Average Un-Biased -5.59E-01 -5.64E-01 -5.49E-01 -5.42E-01 Std Dev Un-Biased 2.08E-02 1.30E-02 1.29E-02 1.53E-02 Ps90%/90% (+KTL) Un-Biased -5.02E-01 -5.28E-01 -5.14E-01 -5.00E-01 Ps90%/90% (-KTL) Un-Biased -6.16E-01 -5.99E-01 -5.84E-01 -5.84E-01 Specification MAX -2.00E-01 -1.30E-01 -1.20E-01 -1.20E-01 Status PASS PASS PASS PASS 50 1/27/2011 -5.33E-01 -5.03E-01 -5.40E-01 -4.83E-01 -5.32E-01 -5.33E-01 -5.30E-01 -5.24E-01 -5.47E-01 -5.45E-01 -5.50E-01 -5.51E-01 168 hr Anneal 70 2/4/2011 -5.52E-01 -5.01E-01 -5.37E-01 -4.88E-01 -5.27E-01 -5.45E-01 -5.32E-01 -5.07E-01 -5.42E-01 -5.40E-01 -5.55E-01 -5.62E-01 -5.18E-01 -5.24E-01 -5.21E-01 2.43E-02 2.74E-02 2.62E-02 -4.52E-01 -4.49E-01 -4.49E-01 -5.85E-01 -5.99E-01 -5.93E-01 -5.36E-01 9.88E-03 -5.09E-01 -5.63E-01 -1.10E-01 PASS An ISO 9001:2008 and DSCC Certified Company 100 24 hr Anneal 60 1/28/2011 -5.43E-01 -5.25E-01 -5.34E-01 -4.77E-01 -5.42E-01 -5.39E-01 -5.23E-01 -5.15E-01 -5.50E-01 -5.51E-01 -5.43E-01 -5.71E-01 -5.36E-01 1.61E-02 -4.91E-01 -5.80E-01 -1.10E-01 PASS -5.33E-01 1.54E-02 -4.91E-01 -5.75E-01 -1.10E-01 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Positive Supply Current @ +5V (A) 2.50E-03 2.00E-03 1.50E-03 1.00E-03 5.00E-04 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.47. Plot of Positive Supply Current @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 101 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.47. Raw data for Positive Supply Current @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Positive Supply Current @ +5V (A) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 1.38E-03 1.39E-03 1.35E-03 1.31E-03 1.23E-03 1.23E-03 1.19E-03 1842 1.33E-03 1.32E-03 1.32E-03 1.28E-03 1.20E-03 1.20E-03 1.15E-03 1843 1.37E-03 1.37E-03 1.34E-03 1.29E-03 1.21E-03 1.21E-03 1.18E-03 1844 1.34E-03 1.37E-03 1.34E-03 1.31E-03 1.23E-03 1.23E-03 1.18E-03 1845 1.35E-03 1.35E-03 1.34E-03 1.31E-03 1.23E-03 1.23E-03 1.18E-03 1846 1.41E-03 1.44E-03 1.41E-03 1.38E-03 1.33E-03 1.33E-03 1.31E-03 1847 1.37E-03 1.45E-03 1.43E-03 1.40E-03 1.34E-03 1.35E-03 1.33E-03 1848 1.32E-03 1.41E-03 1.39E-03 1.36E-03 1.30E-03 1.31E-03 1.29E-03 1849 1.37E-03 1.43E-03 1.41E-03 1.38E-03 1.32E-03 1.32E-03 1.30E-03 1850 1.41E-03 1.50E-03 1.47E-03 1.44E-03 1.39E-03 1.39E-03 1.37E-03 1851 1.33E-03 1.33E-03 1.33E-03 1.33E-03 1.33E-03 1.33E-03 1.33E-03 1852 1.42E-03 1.42E-03 1.41E-03 1.41E-03 1.41E-03 1.41E-03 1.41E-03 Biased Statistics Average Biased 1.35E-03 1.36E-03 1.34E-03 1.30E-03 1.22E-03 1.22E-03 1.18E-03 Std Dev Biased 2.00E-05 2.53E-05 1.37E-05 1.37E-05 1.33E-05 1.24E-05 1.48E-05 Ps90%/90% (+KTL) Biased 1.41E-03 1.43E-03 1.38E-03 1.34E-03 1.26E-03 1.25E-03 1.22E-03 Ps90%/90% (-KTL) Biased 1.30E-03 1.29E-03 1.30E-03 1.26E-03 1.18E-03 1.18E-03 1.14E-03 Un-Biased Statistics Average Un-Biased 1.37E-03 1.45E-03 1.42E-03 1.39E-03 1.34E-03 1.34E-03 1.32E-03 Std Dev Un-Biased 3.70E-05 3.10E-05 3.07E-05 3.20E-05 3.28E-05 3.02E-05 3.20E-05 Ps90%/90% (+KTL) Un-Biased 1.47E-03 1.53E-03 1.51E-03 1.48E-03 1.43E-03 1.42E-03 1.41E-03 Ps90%/90% (-KTL) Un-Biased 1.27E-03 1.36E-03 1.34E-03 1.31E-03 1.25E-03 1.26E-03 1.23E-03 Specification MAX 2.00E-03 2.00E-03 2.00E-03 2.00E-03 2.00E-03 2.00E-03 2.00E-03 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 102 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Negative Supply Current @ +5V (A) 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 -2.00E-03 -2.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.48. Plot of Negative Supply Current @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 103 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.48. Raw data for Negative Supply Current @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Supply Current @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -1.36E-03 -1.37E-03 -1.33E-03 -1.30E-03 1842 -1.31E-03 -1.30E-03 -1.30E-03 -1.27E-03 1843 -1.34E-03 -1.35E-03 -1.31E-03 -1.28E-03 1844 -1.32E-03 -1.34E-03 -1.32E-03 -1.30E-03 1845 -1.33E-03 -1.34E-03 -1.32E-03 -1.29E-03 1846 -1.38E-03 -1.41E-03 -1.39E-03 -1.36E-03 1847 -1.34E-03 -1.43E-03 -1.41E-03 -1.38E-03 1848 -1.30E-03 -1.39E-03 -1.36E-03 -1.34E-03 1849 -1.34E-03 -1.41E-03 -1.38E-03 -1.34E-03 1850 -1.38E-03 -1.48E-03 -1.45E-03 -1.42E-03 1851 -1.31E-03 -1.32E-03 -1.31E-03 -1.31E-03 1852 -1.40E-03 -1.40E-03 -1.40E-03 -1.38E-03 Biased Statistics Average Biased -1.33E-03 -1.34E-03 -1.32E-03 -1.29E-03 Std Dev Biased 1.98E-05 2.54E-05 1.28E-05 1.37E-05 Ps90%/90% (+KTL) Biased -1.28E-03 -1.27E-03 -1.28E-03 -1.25E-03 Ps90%/90% (-KTL) Biased -1.39E-03 -1.41E-03 -1.35E-03 -1.33E-03 Un-Biased Statistics Average Un-Biased -1.35E-03 -1.42E-03 -1.40E-03 -1.37E-03 Std Dev Un-Biased 3.52E-05 3.36E-05 3.50E-05 3.49E-05 Ps90%/90% (+KTL) Un-Biased -1.25E-03 -1.33E-03 -1.30E-03 -1.27E-03 Ps90%/90% (-KTL) Un-Biased -1.45E-03 -1.52E-03 -1.49E-03 -1.46E-03 Specification MIN -2.00E-03 -2.00E-03 -2.00E-03 -2.00E-03 Status PASS PASS PASS PASS 50 1/27/2011 -1.20E-03 -1.17E-03 -1.18E-03 -1.20E-03 -1.21E-03 -1.30E-03 -1.32E-03 -1.28E-03 -1.29E-03 -1.37E-03 -1.30E-03 -1.39E-03 168 hr Anneal 70 2/4/2011 -1.17E-03 -1.14E-03 -1.15E-03 -1.17E-03 -1.16E-03 -1.29E-03 -1.30E-03 -1.26E-03 -1.28E-03 -1.35E-03 -1.31E-03 -1.39E-03 -1.19E-03 -1.20E-03 -1.16E-03 1.37E-05 1.27E-05 1.50E-05 -1.16E-03 -1.16E-03 -1.12E-03 -1.23E-03 -1.23E-03 -1.20E-03 -1.31E-03 3.64E-05 -1.21E-03 -1.41E-03 -2.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 104 24 hr Anneal 60 1/28/2011 -1.21E-03 -1.18E-03 -1.19E-03 -1.21E-03 -1.20E-03 -1.30E-03 -1.33E-03 -1.29E-03 -1.30E-03 -1.37E-03 -1.31E-03 -1.38E-03 -1.31E-03 3.17E-05 -1.23E-03 -1.40E-03 -2.00E-03 PASS -1.30E-03 3.25E-05 -1.21E-03 -1.38E-03 -2.00E-03 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 1 @ +5V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.49. Plot of Offset Voltage 1 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 105 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.49. Raw data for Offset Voltage 1 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Voltage 1 @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -5.17E-05 -1.82E-05 -9.97E-06 4.15E-07 1842 -8.28E-05 -7.21E-05 -6.37E-05 -5.25E-05 1843 -1.22E-04 -1.10E-04 -1.04E-04 -9.42E-05 1844 -4.18E-05 -4.03E-05 -2.96E-05 -2.14E-05 1845 -1.45E-04 -1.37E-04 -1.29E-04 -1.16E-04 1846 -1.02E-04 -9.29E-05 -8.63E-05 -8.11E-05 1847 -3.95E-05 -3.42E-05 -2.45E-05 -1.88E-05 1848 -5.89E-05 -5.16E-05 -4.59E-05 -3.95E-05 1849 -3.51E-05 -2.93E-05 -2.19E-05 -1.36E-05 1850 -6.24E-05 -5.51E-05 -4.92E-05 -4.38E-05 1851 -2.42E-05 -2.47E-05 -2.45E-05 -2.34E-05 1852 2.71E-06 2.35E-06 2.71E-06 2.47E-06 Biased Statistics Average Biased -8.87E-05 -7.56E-05 -6.71E-05 -5.67E-05 Std Dev Biased 4.45E-05 4.89E-05 4.95E-05 4.85E-05 Ps90%/90% (+KTL) Biased 3.32E-05 5.85E-05 6.86E-05 7.63E-05 Ps90%/90% (-KTL) Biased -2.11E-04 -2.10E-04 -2.03E-04 -1.90E-04 Un-Biased Statistics Average Un-Biased -5.96E-05 -5.26E-05 -4.56E-05 -3.94E-05 Std Dev Un-Biased 2.65E-05 2.51E-05 2.59E-05 2.67E-05 Ps90%/90% (+KTL) Un-Biased 1.31E-05 1.61E-05 2.53E-05 3.38E-05 Ps90%/90% (-KTL) Un-Biased -1.32E-04 -1.21E-04 -1.16E-04 -1.13E-04 Specification MIN -4.50E-04 -6.00E-04 -6.00E-04 -6.00E-04 Status PASS PASS PASS PASS Specification MAX 4.50E-04 6.00E-04 6.00E-04 6.00E-04 Status PASS PASS PASS PASS 50 1/27/2011 1.72E-05 -3.74E-05 -7.95E-05 -4.17E-06 -1.00E-04 -6.69E-05 -2.48E-06 -3.07E-05 -5.62E-06 -3.56E-05 -2.48E-05 1.14E-06 168 hr Anneal 70 2/4/2011 5.52E-05 -2.65E-05 -4.47E-05 -3.33E-05 -8.35E-05 -7.77E-05 -6.11E-06 -2.47E-05 -5.50E-06 -4.40E-05 -2.36E-05 2.47E-06 -4.08E-05 -4.06E-05 -2.66E-05 4.93E-05 4.83E-05 5.08E-05 9.44E-05 9.19E-05 1.13E-04 -1.76E-04 -1.73E-04 -1.66E-04 -2.83E-05 2.61E-05 4.34E-05 -9.99E-05 -7.50E-04 PASS 7.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 106 24 hr Anneal 60 1/28/2011 1.67E-05 -3.70E-05 -8.08E-05 -5.14E-06 -9.69E-05 -6.79E-05 -4.05E-06 -2.89E-05 -4.53E-06 -3.59E-05 -2.41E-05 1.50E-06 -2.83E-05 2.64E-05 4.40E-05 -1.01E-04 -7.50E-04 PASS 7.50E-04 PASS -3.16E-05 3.02E-05 5.13E-05 -1.15E-04 -7.50E-04 PASS 7.50E-04 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 2 @ +5V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.50. Plot of Offset Voltage 2 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 107 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.50. Raw data for Offset Voltage 2 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Voltage 2 @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.83E-05 9.96E-06 1.79E-05 2.24E-05 1842 6.48E-05 6.67E-05 7.73E-05 8.65E-05 1843 5.98E-05 6.96E-05 8.18E-05 8.85E-05 1844 7.06E-06 1.32E-05 2.58E-05 3.46E-05 1845 2.49E-05 2.73E-05 3.98E-05 5.10E-05 1846 -7.19E-06 -5.74E-06 -1.16E-06 1.14E-06 1847 -4.58E-05 -4.14E-05 -3.38E-05 -2.65E-05 1848 2.08E-05 3.13E-05 3.53E-05 3.81E-05 1849 2.55E-05 3.34E-05 3.96E-05 4.41E-05 1850 3.88E-05 4.87E-05 5.33E-05 5.76E-05 1851 3.80E-06 4.65E-06 4.03E-06 4.64E-06 1852 -4.45E-05 -4.42E-05 -4.35E-05 -4.34E-05 Biased Statistics Average Biased 3.50E-05 3.74E-05 4.85E-05 5.66E-05 Std Dev Biased 2.58E-05 2.89E-05 2.94E-05 3.00E-05 Ps90%/90% (+KTL) Biased 1.06E-04 1.17E-04 1.29E-04 1.39E-04 Ps90%/90% (-KTL) Biased -3.58E-05 -4.18E-05 -3.22E-05 -2.57E-05 Un-Biased Statistics Average Un-Biased 6.43E-06 1.33E-05 1.87E-05 2.29E-05 Std Dev Un-Biased 3.37E-05 3.65E-05 3.56E-05 3.46E-05 Ps90%/90% (+KTL) Un-Biased 9.88E-05 1.13E-04 1.16E-04 1.18E-04 Ps90%/90% (-KTL) Un-Biased -8.59E-05 -8.68E-05 -7.88E-05 -7.21E-05 Specification MIN -4.50E-04 -6.00E-04 -6.00E-04 -6.00E-04 Status PASS PASS PASS PASS Specification MAX 4.50E-04 6.00E-04 6.00E-04 6.00E-04 Status PASS PASS PASS PASS 50 1/27/2011 3.77E-05 1.06E-04 1.04E-04 5.41E-05 7.39E-05 1.07E-05 -9.72E-06 4.94E-05 5.76E-05 7.15E-05 4.89E-06 -4.32E-05 7.51E-05 7.43E-05 5.79E-05 3.00E-05 3.10E-05 3.35E-05 1.57E-04 1.59E-04 1.50E-04 -7.20E-06 -1.08E-05 -3.41E-05 3.59E-05 3.41E-05 1.29E-04 -5.75E-05 -7.50E-04 PASS 7.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 108 24 hr 168 hr Anneal Anneal 60 70 1/28/2011 2/4/2011 3.59E-05 8.38E-06 1.05E-04 9.93E-05 1.05E-04 7.27E-05 5.20E-05 4.77E-05 7.36E-05 6.11E-05 1.03E-05 -4.40E-05 -1.08E-05 -3.30E-05 5.08E-05 4.38E-05 5.69E-05 3.37E-05 7.00E-05 5.66E-05 4.64E-06 4.64E-06 -4.39E-05 -4.33E-05 3.54E-05 3.41E-05 1.29E-04 -5.81E-05 -7.50E-04 PASS 7.50E-04 PASS 1.14E-05 4.64E-05 1.39E-04 -1.16E-04 -7.50E-04 PASS 7.50E-04 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 3 @ +5V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.51. Plot of Offset Voltage 3 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 109 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.51. Raw data for Offset Voltage 3 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Voltage 3 @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -7.59E-05 -7.09E-05 -6.53E-05 -6.14E-05 1842 -5.58E-05 -5.35E-05 -4.49E-05 -3.97E-05 1843 -1.22E-04 -1.14E-04 -1.06E-04 -9.98E-05 1844 -4.40E-05 -3.76E-05 -3.04E-05 -2.31E-05 1845 -7.56E-05 -6.95E-05 -6.15E-05 -5.40E-05 1846 -9.48E-06 -7.43E-06 -2.61E-06 1.38E-06 1847 4.94E-05 5.82E-05 6.67E-05 7.29E-05 1848 -7.41E-05 -6.65E-05 -5.40E-05 -4.63E-05 1849 -1.17E-04 -1.09E-04 -9.99E-05 -9.13E-05 1850 1.79E-05 2.57E-05 3.28E-05 3.78E-05 1851 -6.33E-05 -6.28E-05 -6.21E-05 -6.16E-05 1852 -3.50E-05 -3.64E-05 -3.48E-05 -3.64E-05 Biased Statistics Average Biased -7.47E-05 -6.91E-05 -6.17E-05 -5.56E-05 Std Dev Biased 2.99E-05 2.85E-05 2.86E-05 2.87E-05 Ps90%/90% (+KTL) Biased 7.19E-06 9.00E-06 1.68E-05 2.31E-05 Ps90%/90% (-KTL) Biased -1.57E-04 -1.47E-04 -1.40E-04 -1.34E-04 Un-Biased Statistics Average Un-Biased -2.67E-05 -1.97E-05 -1.14E-05 -5.11E-06 Std Dev Un-Biased 6.80E-05 6.78E-05 6.67E-05 6.54E-05 Ps90%/90% (+KTL) Un-Biased 1.60E-04 1.66E-04 1.71E-04 1.74E-04 Ps90%/90% (-KTL) Un-Biased -2.13E-04 -2.06E-04 -1.94E-04 -1.84E-04 Specification MIN -4.50E-04 -6.00E-04 -6.00E-04 -6.00E-04 Status PASS PASS PASS PASS Specification MAX 4.50E-04 6.00E-04 6.00E-04 6.00E-04 Status PASS PASS PASS PASS 50 1/27/2011 -4.98E-05 -2.42E-05 -8.00E-05 -6.46E-06 -3.01E-05 8.87E-06 9.23E-05 -2.94E-05 -7.65E-05 5.21E-05 -6.14E-05 -3.54E-05 168 hr Anneal 70 2/4/2011 -4.82E-05 -4.92E-05 -6.89E-05 -8.16E-06 -1.96E-05 -1.29E-05 7.39E-05 -3.29E-05 -8.47E-05 4.29E-05 -6.19E-05 -3.53E-05 -3.81E-05 -3.92E-05 -3.88E-05 2.81E-05 2.75E-05 2.45E-05 3.88E-05 3.62E-05 2.85E-05 -1.15E-04 -1.15E-04 -1.06E-04 9.47E-06 6.63E-05 1.91E-04 -1.72E-04 -7.50E-04 PASS 7.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 110 24 hr Anneal 60 1/28/2011 -5.08E-05 -2.51E-05 -8.06E-05 -9.24E-06 -3.04E-05 7.90E-06 9.01E-05 -2.99E-05 -7.90E-05 5.20E-05 -6.25E-05 -3.54E-05 8.22E-06 6.65E-05 1.91E-04 -1.74E-04 -7.50E-04 PASS 7.50E-04 PASS -2.73E-06 6.26E-05 1.69E-04 -1.74E-04 -7.50E-04 PASS 7.50E-04 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 4 @ +5V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.52. Plot of Offset Voltage 4 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 111 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.52. Raw data for Offset Voltage 4 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Voltage 4 @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -1.70E-05 -1.44E-05 -5.14E-06 5.24E-06 1842 -5.79E-05 -5.27E-05 -3.93E-05 -3.33E-05 1843 3.80E-06 1.27E-05 1.71E-05 2.15E-05 1844 6.16E-05 6.63E-05 7.65E-05 8.91E-05 1845 5.73E-06 8.63E-06 1.74E-05 2.44E-05 1846 -1.43E-05 -1.21E-05 -5.99E-06 -1.03E-06 1847 1.66E-05 2.23E-05 2.76E-05 3.66E-05 1848 1.26E-05 1.99E-05 2.56E-05 3.12E-05 1849 -1.87E-05 -1.30E-05 -4.30E-06 4.15E-07 1850 -9.18E-05 -8.17E-05 -7.53E-05 -6.67E-05 1851 5.02E-05 5.19E-05 5.20E-05 5.14E-05 1852 8.07E-05 8.03E-05 8.05E-05 7.95E-05 Biased Statistics Average Biased -7.39E-07 4.12E-06 1.33E-05 2.14E-05 Std Dev Biased 4.32E-05 4.34E-05 4.22E-05 4.43E-05 Ps90%/90% (+KTL) Biased 1.18E-04 1.23E-04 1.29E-04 1.43E-04 Ps90%/90% (-KTL) Biased -1.19E-04 -1.15E-04 -1.02E-04 -1.00E-04 Un-Biased Statistics Average Un-Biased -1.91E-05 -1.29E-05 -6.47E-06 1.01E-07 Std Dev Un-Biased 4.36E-05 4.20E-05 4.16E-05 4.11E-05 Ps90%/90% (+KTL) Un-Biased 1.00E-04 1.02E-04 1.08E-04 1.13E-04 Ps90%/90% (-KTL) Un-Biased -1.39E-04 -1.28E-04 -1.21E-04 -1.13E-04 Specification MIN -4.50E-04 -6.00E-04 -6.00E-04 -6.00E-04 Status PASS PASS PASS PASS Specification MAX 4.50E-04 6.00E-04 6.00E-04 6.00E-04 Status PASS PASS PASS PASS 50 1/27/2011 2.42E-05 -1.36E-05 2.67E-05 1.11E-04 4.27E-05 6.70E-06 4.41E-05 4.70E-05 1.35E-05 -4.74E-05 5.15E-05 7.90E-05 3.83E-05 3.83E-05 3.31E-05 4.57E-05 4.62E-05 5.63E-05 1.64E-04 1.65E-04 1.87E-04 -8.71E-05 -8.83E-05 -1.21E-04 1.28E-05 3.81E-05 1.17E-04 -9.17E-05 -7.50E-04 PASS 7.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 112 24 hr 168 hr Anneal Anneal 60 70 1/28/2011 2/4/2011 2.52E-05 6.33E-06 -1.47E-05 -2.78E-05 2.69E-05 1.78E-05 1.12E-04 1.22E-04 4.24E-05 4.75E-05 6.70E-06 -1.36E-05 4.58E-05 2.49E-05 4.69E-05 4.83E-05 1.47E-05 1.73E-07 -4.84E-05 -4.98E-05 5.22E-05 5.17E-05 7.93E-05 7.94E-05 1.31E-05 3.88E-05 1.20E-04 -9.33E-05 -7.50E-04 PASS 7.50E-04 PASS 2.01E-06 3.74E-05 1.05E-04 -1.01E-04 -7.50E-04 PASS 7.50E-04 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.00E-08 Offset Current 1 @ +5V (A) 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.53. Plot of Offset Current 1 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 113 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.53. Raw data for Offset Current 1 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Current 1 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -5.20E-11 -5.40E-11 -8.70E-11 -1.23E-10 1842 -1.27E-10 -1.61E-10 -9.20E-11 -5.90E-11 1843 4.00E-12 2.40E-11 2.30E-11 1.25E-10 1844 7.00E-12 -7.00E-12 1.30E-11 8.40E-11 1845 -3.50E-11 -1.06E-10 -1.89E-10 -3.28E-10 1846 6.60E-11 3.00E-12 -5.50E-11 -2.30E-11 1847 -5.60E-11 -1.30E-11 2.20E-11 -7.20E-11 1848 -2.90E-11 -2.50E-11 -1.13E-10 -1.12E-10 1849 5.00E-12 -2.40E-11 -6.30E-11 -1.16E-10 1850 -2.00E-12 4.50E-11 -2.20E-11 -1.09E-10 1851 -1.00E-12 2.20E-11 4.20E-11 6.10E-11 1852 -3.00E-12 -2.10E-11 -5.00E-12 -1.40E-11 Biased Statistics Average Biased -4.06E-11 -6.08E-11 -6.64E-11 -6.02E-11 Std Dev Biased 5.45E-11 7.45E-11 8.72E-11 1.81E-10 Ps90%/90% (+KTL) Biased 1.09E-10 1.44E-10 1.73E-10 4.36E-10 Ps90%/90% (-KTL) Biased -1.90E-10 -2.65E-10 -3.05E-10 -5.56E-10 Un-Biased Statistics Average Un-Biased -3.20E-12 -2.80E-12 -4.62E-11 -8.64E-11 Std Dev Un-Biased 4.56E-11 2.90E-11 5.01E-11 3.96E-11 Ps90%/90% (+KTL) Un-Biased 1.22E-10 7.67E-11 9.13E-11 2.22E-11 Ps90%/90% (-KTL) Un-Biased -1.28E-10 -8.23E-11 -1.84E-10 -1.95E-10 Specification MIN -1.00E-08 -1.00E-08 -1.00E-08 -1.00E-08 Status PASS PASS PASS PASS Specification MAX 1.00E-08 1.00E-08 1.00E-08 1.00E-08 Status PASS PASS PASS PASS 50 1/27/2011 -2.30E-11 -9.00E-11 2.53E-10 2.01E-10 -3.39E-10 -1.04E-10 9.80E-11 -9.70E-11 -9.40E-11 -2.30E-11 4.50E-11 -1.90E-11 168 hr Anneal 70 2/4/2011 0.00E+00 -1.03E-10 -6.90E-11 8.40E-11 -1.85E-10 -5.70E-11 -1.30E-11 -8.90E-11 -4.40E-11 2.80E-11 4.80E-11 -1.60E-11 4.00E-13 -3.52E-11 -5.46E-11 2.39E-10 2.75E-10 1.02E-10 6.55E-10 7.19E-10 2.26E-10 -6.54E-10 -7.90E-10 -3.35E-10 -4.40E-11 8.59E-11 1.92E-10 -2.80E-10 -1.50E-08 PASS 1.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 114 24 hr Anneal 60 1/28/2011 -2.60E-11 -1.04E-10 1.77E-10 2.36E-10 -4.59E-10 -1.90E-11 1.01E-10 -9.70E-11 -8.10E-11 -6.50E-11 4.60E-11 -3.20E-11 -3.22E-11 8.00E-11 1.87E-10 -2.51E-10 -1.50E-08 PASS 1.50E-08 PASS -3.50E-11 4.45E-11 8.71E-11 -1.57E-10 -1.50E-08 PASS 1.50E-08 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.00E-08 Offset Current 2 @ +5V (A) 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.54. Plot of Offset Current 2 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 115 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.54. Raw data for Offset Current 2 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Current 2 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -4.40E-11 -1.29E-10 -1.33E-10 -8.10E-11 1842 -1.22E-10 -1.64E-10 -2.58E-10 -2.48E-10 1843 8.00E-12 -8.30E-11 -4.50E-11 -4.00E-11 1844 -7.70E-11 -1.90E-11 4.20E-11 1.63E-10 1845 -5.10E-11 -3.40E-11 -3.60E-11 -8.80E-11 1846 -2.00E-11 1.80E-11 -5.90E-11 2.20E-11 1847 9.00E-12 4.50E-11 -1.30E-11 1.57E-10 1848 -1.12E-10 -8.60E-11 -6.60E-11 -1.00E-11 1849 -1.50E-11 -1.80E-11 -1.30E-11 4.50E-11 1850 -1.61E-10 -2.47E-10 -1.75E-10 -2.08E-10 1851 -1.77E-10 -1.50E-10 -1.54E-10 -1.68E-10 1852 -2.24E-10 -2.27E-10 -2.33E-10 -2.26E-10 Biased Statistics Average Biased -5.72E-11 -8.58E-11 -8.60E-11 -5.88E-11 Std Dev Biased 4.76E-11 6.15E-11 1.14E-10 1.47E-10 Ps90%/90% (+KTL) Biased 7.33E-11 8.29E-11 2.28E-10 3.45E-10 Ps90%/90% (-KTL) Biased -1.88E-10 -2.54E-10 -4.00E-10 -4.62E-10 Un-Biased Statistics Average Un-Biased -5.98E-11 -5.76E-11 -6.52E-11 1.20E-12 Std Dev Un-Biased 7.30E-11 1.17E-10 6.62E-11 1.33E-10 Ps90%/90% (+KTL) Un-Biased 1.40E-10 2.62E-10 1.16E-10 3.65E-10 Ps90%/90% (-KTL) Un-Biased -2.60E-10 -3.78E-10 -2.47E-10 -3.63E-10 Specification MIN -1.00E-08 -1.00E-08 -1.00E-08 -1.00E-08 Status PASS PASS PASS PASS Specification MAX 1.00E-08 1.00E-08 1.00E-08 1.00E-08 Status PASS PASS PASS PASS 50 1/27/2011 -1.25E-10 -3.05E-10 -1.33E-10 2.12E-10 1.00E-11 2.65E-10 7.60E-11 -7.50E-11 -9.10E-11 -2.35E-10 -1.48E-10 -2.04E-10 168 hr Anneal 70 2/4/2011 -1.05E-10 -2.21E-10 5.00E-11 -3.60E-11 1.07E-10 9.00E-11 7.50E-11 -1.40E-11 1.26E-10 -2.04E-10 -1.50E-10 -2.16E-10 -6.82E-11 -7.00E-11 -4.10E-11 1.92E-10 1.76E-10 1.29E-10 4.59E-10 4.14E-10 3.13E-10 -5.96E-10 -5.54E-10 -3.95E-10 -1.20E-11 1.90E-10 5.09E-10 -5.33E-10 -1.50E-08 PASS 1.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 116 24 hr Anneal 60 1/28/2011 -1.03E-10 -2.94E-10 -1.37E-10 1.82E-10 2.00E-12 2.05E-10 6.30E-11 -6.80E-11 -4.80E-11 -2.40E-10 -1.69E-10 -2.22E-10 -1.76E-11 1.65E-10 4.35E-10 -4.70E-10 -1.50E-08 PASS 1.50E-08 PASS 1.46E-11 1.33E-10 3.78E-10 -3.49E-10 -1.50E-08 PASS 1.50E-08 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.00E-08 Offset Current 3 @ +5V (A) 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.55. Plot of Offset Current 3 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 117 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.55. Raw data for Offset Current 3 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Current 3 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -5.30E-11 2.60E-11 1.00E-11 8.20E-11 1842 -4.00E-12 1.90E-11 1.53E-10 1.36E-10 1843 3.90E-11 -2.70E-11 -3.00E-11 7.40E-11 1844 2.60E-11 1.70E-11 -2.60E-11 1.03E-10 1845 -8.30E-11 -1.22E-10 -1.70E-10 -1.08E-10 1846 -9.50E-11 -1.01E-10 -2.10E-11 -9.60E-11 1847 -2.90E-11 1.80E-11 -1.00E-11 7.10E-11 1848 -3.90E-11 8.00E-12 7.00E-12 -6.00E-12 1849 3.40E-11 -9.00E-12 2.00E-11 1.50E-11 1850 -5.60E-11 -6.20E-11 -9.40E-11 -4.30E-11 1851 -1.76E-10 -1.60E-10 -1.55E-10 -1.53E-10 1852 1.15E-10 1.03E-10 1.00E-10 1.01E-10 Biased Statistics Average Biased -1.50E-11 -1.74E-11 -1.26E-11 5.74E-11 Std Dev Biased 5.19E-11 6.21E-11 1.15E-10 9.55E-11 Ps90%/90% (+KTL) Biased 1.27E-10 1.53E-10 3.04E-10 3.19E-10 Ps90%/90% (-KTL) Biased -1.57E-10 -1.88E-10 -3.29E-10 -2.05E-10 Un-Biased Statistics Average Un-Biased -3.70E-11 -2.92E-11 -1.96E-11 -1.18E-11 Std Dev Un-Biased 4.70E-11 5.06E-11 4.45E-11 6.26E-11 Ps90%/90% (+KTL) Un-Biased 9.19E-11 1.10E-10 1.02E-10 1.60E-10 Ps90%/90% (-KTL) Un-Biased -1.66E-10 -1.68E-10 -1.41E-10 -1.83E-10 Specification MIN -1.00E-08 -1.00E-08 -1.00E-08 -1.00E-08 Status PASS PASS PASS PASS Specification MAX 1.00E-08 1.00E-08 1.00E-08 1.00E-08 Status PASS PASS PASS PASS 50 1/27/2011 1.14E-10 2.25E-10 1.94E-10 2.21E-10 -4.30E-11 -4.40E-11 1.00E-10 -9.40E-11 -8.00E-12 1.13E-10 -1.72E-10 9.20E-11 168 hr Anneal 70 2/4/2011 1.43E-10 1.24E-10 3.07E-10 8.10E-11 -1.60E-10 -9.10E-11 1.55E-10 -4.70E-11 7.70E-11 1.39E-10 -1.59E-10 1.34E-10 1.42E-10 1.49E-10 9.90E-11 1.13E-10 1.30E-10 1.68E-10 4.51E-10 5.05E-10 5.60E-10 -1.67E-10 -2.06E-10 -3.62E-10 1.34E-11 9.04E-11 2.61E-10 -2.35E-10 -1.50E-08 PASS 1.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 118 24 hr Anneal 60 1/28/2011 1.21E-10 2.40E-10 2.35E-10 2.16E-10 -6.60E-11 -4.70E-11 9.90E-11 -4.80E-11 2.20E-11 5.80E-11 -1.61E-10 1.07E-10 1.68E-11 6.47E-11 1.94E-10 -1.61E-10 -1.50E-08 PASS 1.50E-08 PASS 4.66E-11 1.11E-10 3.50E-10 -2.57E-10 -1.50E-08 PASS 1.50E-08 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.00E-08 Offset Current 4 @ +5V (A) 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.56. Plot of Offset Current 4 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 119 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.56. Raw data for Offset Current 4 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Offset Current 4 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 -1.88E-10 -2.83E-10 -3.20E-10 -4.00E-10 1842 -1.62E-10 -1.53E-10 -1.76E-10 -1.64E-10 1843 -6.00E-11 -2.80E-11 -8.00E-11 -7.00E-12 1844 1.41E-10 2.57E-10 2.46E-10 1.45E-10 1845 -1.02E-10 -1.27E-10 -1.21E-10 -1.24E-10 1846 -7.53E-10 -9.00E-11 -7.90E-11 -1.88E-10 1847 -3.00E-11 -3.80E-11 3.80E-11 -5.20E-11 1848 -1.28E-10 -2.79E-10 -3.56E-10 -3.90E-10 1849 -1.01E-10 -1.58E-10 -2.92E-10 -3.08E-10 1850 -1.97E-10 -2.72E-10 -3.17E-10 -3.98E-10 1851 -6.00E-12 2.40E-11 -9.00E-12 -1.40E-11 1852 2.00E-12 0.00E+00 5.00E-12 -5.00E-12 Biased Statistics Average Biased -7.42E-11 -6.68E-11 -9.02E-11 -1.10E-10 Std Dev Biased 1.30E-10 2.03E-10 2.09E-10 2.02E-10 Ps90%/90% (+KTL) Biased 2.83E-10 4.89E-10 4.82E-10 4.43E-10 Ps90%/90% (-KTL) Biased -4.32E-10 -6.22E-10 -6.63E-10 -6.63E-10 Un-Biased Statistics Average Un-Biased -2.42E-10 -1.67E-10 -2.01E-10 -2.67E-10 Std Dev Un-Biased 2.92E-10 1.07E-10 1.72E-10 1.47E-10 Ps90%/90% (+KTL) Un-Biased 5.59E-10 1.27E-10 2.69E-10 1.36E-10 Ps90%/90% (-KTL) Un-Biased -1.04E-09 -4.62E-10 -6.72E-10 -6.70E-10 Specification MIN -1.00E-08 -1.00E-08 -1.00E-08 -1.00E-08 Status PASS PASS PASS PASS Specification MAX 1.00E-08 1.00E-08 1.00E-08 1.00E-08 Status PASS PASS PASS PASS 50 1/27/2011 -5.23E-10 -1.78E-10 8.90E-11 3.19E-10 -1.50E-11 -2.10E-10 -5.00E-11 -5.80E-10 -4.96E-10 -4.31E-10 -2.00E-12 -6.00E-12 168 hr Anneal 70 2/4/2011 -3.20E-10 -1.27E-10 -2.00E-11 3.02E-10 -3.50E-11 -4.10E-11 1.36E-10 -3.12E-10 -1.13E-10 -2.39E-10 9.00E-12 2.50E-11 -6.16E-11 -3.12E-11 -4.00E-11 3.15E-10 2.96E-10 2.25E-10 8.01E-10 7.79E-10 5.78E-10 -9.25E-10 -8.42E-10 -6.58E-10 -3.53E-10 2.18E-10 2.45E-10 -9.52E-10 -1.50E-08 PASS 1.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 120 24 hr Anneal 60 1/28/2011 -4.12E-10 -1.97E-10 1.42E-10 3.52E-10 -4.10E-11 -1.68E-10 -3.60E-11 -4.78E-10 -4.28E-10 -3.65E-10 -8.00E-12 -3.00E-12 -2.95E-10 1.87E-10 2.17E-10 -8.07E-10 -1.50E-08 PASS 1.50E-08 PASS -1.14E-10 1.75E-10 3.66E-10 -5.94E-10 -1.50E-08 PASS 1.50E-08 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 1 @ +5V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.57. Plot of Positive Bias Current 1 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 121 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.57. Raw data for Positive Bias Current 1 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Bias Current 1 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.17E-08 1.47E-08 1.79E-08 2.12E-08 1842 1.20E-08 1.49E-08 1.80E-08 2.13E-08 1843 1.08E-08 1.37E-08 1.68E-08 2.00E-08 1844 1.26E-08 1.56E-08 1.89E-08 2.21E-08 1845 1.17E-08 1.47E-08 1.81E-08 2.15E-08 1846 1.27E-08 1.42E-08 1.62E-08 1.82E-08 1847 1.18E-08 1.39E-08 1.60E-08 1.80E-08 1848 1.20E-08 1.44E-08 1.65E-08 1.85E-08 1849 1.17E-08 1.40E-08 1.62E-08 1.82E-08 1850 1.26E-08 1.50E-08 1.71E-08 1.92E-08 1851 1.15E-08 1.15E-08 1.15E-08 1.15E-08 1852 1.19E-08 1.19E-08 1.18E-08 1.18E-08 Biased Statistics Average Biased 1.18E-08 1.47E-08 1.79E-08 2.12E-08 Std Dev Biased 6.50E-10 6.74E-10 7.25E-10 7.97E-10 Ps90%/90% (+KTL) Biased 1.36E-08 1.66E-08 1.99E-08 2.34E-08 Ps90%/90% (-KTL) Biased 9.99E-09 1.29E-08 1.60E-08 1.91E-08 Un-Biased Statistics Average Un-Biased 1.22E-08 1.43E-08 1.64E-08 1.84E-08 Std Dev Un-Biased 4.78E-10 4.31E-10 4.49E-10 4.96E-10 Ps90%/90% (+KTL) Un-Biased 1.35E-08 1.55E-08 1.76E-08 1.98E-08 Ps90%/90% (-KTL) Un-Biased 1.09E-08 1.31E-08 1.52E-08 1.71E-08 Specification MIN -5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 Status PASS PASS PASS PASS Specification MAX 5.00E-08 8.00E-08 1.00E-07 1.00E-07 Status PASS PASS PASS PASS 50 1/27/2011 2.84E-08 2.83E-08 2.72E-08 2.95E-08 2.90E-08 2.29E-08 2.25E-08 2.31E-08 2.29E-08 2.40E-08 1.15E-08 1.18E-08 24 hr Anneal 60 1/28/2011 2.85E-08 2.84E-08 2.73E-08 2.95E-08 2.91E-08 2.26E-08 2.23E-08 2.29E-08 2.27E-08 2.37E-08 1.15E-08 1.18E-08 168 hr Anneal 70 2/4/2011 2.68E-08 2.69E-08 2.55E-08 2.81E-08 2.71E-08 2.09E-08 2.06E-08 2.10E-08 2.09E-08 2.19E-08 1.15E-08 1.18E-08 2.85E-08 8.73E-10 3.09E-08 2.61E-08 2.86E-08 8.50E-10 3.09E-08 2.62E-08 2.69E-08 9.30E-10 2.94E-08 2.43E-08 2.31E-08 2.29E-08 2.10E-08 5.61E-10 5.49E-10 4.83E-10 2.46E-08 2.44E-08 2.24E-08 2.15E-08 2.13E-08 1.97E-08 -1.25E-07 -1.25E-07 -1.25E-07 PASS PASS PASS 1.25E-07 1.25E-07 1.25E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 122 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 2 @ +5V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.58. Plot of Positive Bias Current 2 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 123 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.58. Raw data for Positive Bias Current 2 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Bias Current 2 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.13E-08 1.41E-08 1.72E-08 2.03E-08 1842 1.30E-08 1.59E-08 1.94E-08 2.28E-08 1843 1.32E-08 1.64E-08 1.97E-08 2.32E-08 1844 1.26E-08 1.55E-08 1.88E-08 2.21E-08 1845 1.26E-08 1.55E-08 1.88E-08 2.21E-08 1846 1.22E-08 1.44E-08 1.65E-08 1.85E-08 1847 1.26E-08 1.49E-08 1.70E-08 1.90E-08 1848 1.26E-08 1.50E-08 1.70E-08 1.89E-08 1849 1.26E-08 1.46E-08 1.67E-08 1.88E-08 1850 1.38E-08 1.66E-08 1.89E-08 2.12E-08 1851 1.27E-08 1.27E-08 1.26E-08 1.26E-08 1852 1.35E-08 1.35E-08 1.35E-08 1.34E-08 Biased Statistics Average Biased 1.25E-08 1.55E-08 1.88E-08 2.21E-08 Std Dev Biased 7.54E-10 8.29E-10 9.61E-10 1.12E-09 Ps90%/90% (+KTL) Biased 1.46E-08 1.78E-08 2.14E-08 2.52E-08 Ps90%/90% (-KTL) Biased 1.05E-08 1.32E-08 1.61E-08 1.90E-08 Un-Biased Statistics Average Un-Biased 1.28E-08 1.51E-08 1.72E-08 1.93E-08 Std Dev Un-Biased 6.23E-10 8.74E-10 9.77E-10 1.11E-09 Ps90%/90% (+KTL) Un-Biased 1.45E-08 1.75E-08 1.99E-08 2.23E-08 Ps90%/90% (-KTL) Un-Biased 1.11E-08 1.27E-08 1.45E-08 1.62E-08 Specification MIN -5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 Status PASS PASS PASS PASS Specification MAX 5.00E-08 8.00E-08 1.00E-07 1.00E-07 Status PASS PASS PASS PASS 50 1/27/2011 2.74E-08 3.05E-08 3.10E-08 2.95E-08 2.95E-08 2.31E-08 2.37E-08 2.37E-08 2.36E-08 2.67E-08 1.26E-08 1.34E-08 24 hr Anneal 60 1/28/2011 2.75E-08 3.05E-08 3.10E-08 2.96E-08 2.95E-08 2.29E-08 2.35E-08 2.35E-08 2.34E-08 2.64E-08 1.26E-08 1.35E-08 168 hr Anneal 70 2/4/2011 2.58E-08 2.89E-08 2.95E-08 2.83E-08 2.80E-08 2.12E-08 2.16E-08 2.16E-08 2.14E-08 2.43E-08 1.27E-08 1.35E-08 2.96E-08 1.36E-09 3.33E-08 2.58E-08 2.96E-08 1.34E-09 3.33E-08 2.60E-08 2.81E-08 1.41E-09 3.20E-08 2.42E-08 2.42E-08 2.39E-08 2.20E-08 1.47E-09 1.42E-09 1.30E-09 2.82E-08 2.78E-08 2.56E-08 2.01E-08 2.00E-08 1.84E-08 -1.25E-07 -1.25E-07 -1.25E-07 PASS PASS PASS 1.25E-07 1.25E-07 1.25E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 124 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 3 @ +5V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.59. Plot of Positive Bias Current 3 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 125 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.59. Raw data for Positive Bias Current 3 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Bias Current 3 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.08E-08 1.36E-08 1.65E-08 1.96E-08 1842 1.21E-08 1.47E-08 1.79E-08 2.12E-08 1843 1.21E-08 1.50E-08 1.82E-08 2.15E-08 1844 1.22E-08 1.50E-08 1.82E-08 2.14E-08 1845 1.23E-08 1.51E-08 1.83E-08 2.14E-08 1846 1.17E-08 1.40E-08 1.60E-08 1.80E-08 1847 1.22E-08 1.44E-08 1.64E-08 1.83E-08 1848 1.28E-08 1.51E-08 1.71E-08 1.92E-08 1849 1.20E-08 1.43E-08 1.63E-08 1.84E-08 1850 1.32E-08 1.58E-08 1.80E-08 2.02E-08 1851 1.23E-08 1.23E-08 1.23E-08 1.23E-08 1852 1.17E-08 1.18E-08 1.18E-08 1.17E-08 Biased Statistics Average Biased 1.19E-08 1.47E-08 1.78E-08 2.10E-08 Std Dev Biased 6.09E-10 6.48E-10 7.64E-10 8.01E-10 Ps90%/90% (+KTL) Biased 1.36E-08 1.65E-08 1.99E-08 2.32E-08 Ps90%/90% (-KTL) Biased 1.02E-08 1.29E-08 1.58E-08 1.88E-08 Un-Biased Statistics Average Un-Biased 1.24E-08 1.47E-08 1.68E-08 1.88E-08 Std Dev Un-Biased 5.84E-10 7.25E-10 8.33E-10 9.01E-10 Ps90%/90% (+KTL) Un-Biased 1.40E-08 1.67E-08 1.90E-08 2.13E-08 Ps90%/90% (-KTL) Un-Biased 1.08E-08 1.27E-08 1.45E-08 1.63E-08 Specification MIN -5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 Status PASS PASS PASS PASS Specification MAX 5.00E-08 8.00E-08 1.00E-07 1.00E-07 Status PASS PASS PASS PASS 50 1/27/2011 2.66E-08 2.83E-08 2.86E-08 2.86E-08 2.87E-08 2.26E-08 2.28E-08 2.39E-08 2.30E-08 2.52E-08 1.22E-08 1.17E-08 24 hr Anneal 60 1/28/2011 2.67E-08 2.83E-08 2.86E-08 2.87E-08 2.87E-08 2.23E-08 2.26E-08 2.37E-08 2.28E-08 2.51E-08 1.23E-08 1.17E-08 168 hr Anneal 70 2/4/2011 2.49E-08 2.68E-08 2.72E-08 2.73E-08 2.73E-08 2.06E-08 2.08E-08 2.18E-08 2.10E-08 2.30E-08 1.23E-08 1.17E-08 2.81E-08 8.94E-10 3.06E-08 2.57E-08 2.82E-08 8.75E-10 3.06E-08 2.58E-08 2.67E-08 1.04E-09 2.95E-08 2.38E-08 2.35E-08 2.33E-08 2.15E-08 1.10E-09 1.12E-09 9.92E-10 2.65E-08 2.64E-08 2.42E-08 2.05E-08 2.02E-08 1.87E-08 -1.25E-07 -1.25E-07 -1.25E-07 PASS PASS PASS 1.25E-07 1.25E-07 1.25E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 126 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 4 @ +5V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.60. Plot of Positive Bias Current 4 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 127 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.60. Raw data for Positive Bias Current 4 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Bias Current 4 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.21E-08 1.53E-08 1.86E-08 2.21E-08 1842 1.24E-08 1.55E-08 1.87E-08 2.20E-08 1843 1.13E-08 1.43E-08 1.76E-08 2.09E-08 1844 1.30E-08 1.59E-08 1.93E-08 2.28E-08 1845 1.21E-08 1.52E-08 1.85E-08 2.19E-08 1846 1.31E-08 1.46E-08 1.67E-08 1.89E-08 1847 1.23E-08 1.46E-08 1.66E-08 1.87E-08 1848 1.25E-08 1.50E-08 1.71E-08 1.93E-08 1849 1.20E-08 1.44E-08 1.67E-08 1.89E-08 1850 1.30E-08 1.56E-08 1.79E-08 2.01E-08 1851 1.19E-08 1.18E-08 1.18E-08 1.19E-08 1852 1.29E-08 1.29E-08 1.29E-08 1.28E-08 Biased Statistics Average Biased 1.22E-08 1.52E-08 1.85E-08 2.19E-08 Std Dev Biased 6.08E-10 5.96E-10 6.22E-10 6.82E-10 Ps90%/90% (+KTL) Biased 1.38E-08 1.69E-08 2.02E-08 2.38E-08 Ps90%/90% (-KTL) Biased 1.05E-08 1.36E-08 1.68E-08 2.01E-08 Un-Biased Statistics Average Un-Biased 1.26E-08 1.48E-08 1.70E-08 1.92E-08 Std Dev Un-Biased 4.55E-10 4.96E-10 5.21E-10 5.65E-10 Ps90%/90% (+KTL) Un-Biased 1.38E-08 1.62E-08 1.84E-08 2.07E-08 Ps90%/90% (-KTL) Un-Biased 1.13E-08 1.35E-08 1.56E-08 1.76E-08 Specification MIN -5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 Status PASS PASS PASS PASS Specification MAX 5.00E-08 8.00E-08 1.00E-07 1.00E-07 Status PASS PASS PASS PASS 50 1/27/2011 2.97E-08 2.93E-08 2.83E-08 3.04E-08 2.97E-08 2.38E-08 2.34E-08 2.41E-08 2.39E-08 2.52E-08 1.18E-08 1.29E-08 24 hr Anneal 60 1/28/2011 2.98E-08 2.95E-08 2.83E-08 3.05E-08 2.97E-08 2.35E-08 2.32E-08 2.39E-08 2.36E-08 2.50E-08 1.19E-08 1.29E-08 168 hr Anneal 70 2/4/2011 2.80E-08 2.78E-08 2.65E-08 2.90E-08 2.79E-08 2.15E-08 2.13E-08 2.18E-08 2.15E-08 2.28E-08 1.18E-08 1.29E-08 2.95E-08 7.83E-10 3.16E-08 2.73E-08 2.96E-08 7.69E-10 3.17E-08 2.74E-08 2.78E-08 8.91E-10 3.03E-08 2.54E-08 2.41E-08 2.38E-08 2.18E-08 6.71E-10 6.79E-10 5.86E-10 2.59E-08 2.57E-08 2.34E-08 2.22E-08 2.20E-08 2.02E-08 -1.25E-07 -1.25E-07 -1.25E-07 PASS PASS PASS 1.25E-07 1.25E-07 1.25E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 128 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 1 @ +5V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.61. Plot of Negative Bias Current 1 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 129 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.61. Raw data for Negative Bias Current 1 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Bias Current 1 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.17E-08 1.46E-08 1.79E-08 2.11E-08 1842 1.18E-08 1.47E-08 1.80E-08 2.12E-08 1843 1.08E-08 1.38E-08 1.68E-08 2.01E-08 1844 1.27E-08 1.56E-08 1.89E-08 2.22E-08 1845 1.17E-08 1.46E-08 1.79E-08 2.12E-08 1846 1.29E-08 1.41E-08 1.61E-08 1.82E-08 1847 1.17E-08 1.39E-08 1.60E-08 1.79E-08 1848 1.19E-08 1.44E-08 1.64E-08 1.84E-08 1849 1.17E-08 1.40E-08 1.61E-08 1.81E-08 1850 1.26E-08 1.50E-08 1.70E-08 1.91E-08 1851 1.15E-08 1.16E-08 1.16E-08 1.16E-08 1852 1.18E-08 1.18E-08 1.18E-08 1.18E-08 Biased Statistics Average Biased 1.17E-08 1.47E-08 1.79E-08 2.12E-08 Std Dev Biased 6.56E-10 6.46E-10 7.22E-10 7.41E-10 Ps90%/90% (+KTL) Biased 1.35E-08 1.64E-08 1.99E-08 2.32E-08 Ps90%/90% (-KTL) Biased 9.94E-09 1.29E-08 1.59E-08 1.91E-08 Un-Biased Statistics Average Un-Biased 1.21E-08 1.43E-08 1.63E-08 1.83E-08 Std Dev Un-Biased 5.51E-10 4.18E-10 4.30E-10 4.76E-10 Ps90%/90% (+KTL) Un-Biased 1.37E-08 1.54E-08 1.75E-08 1.96E-08 Ps90%/90% (-KTL) Un-Biased 1.06E-08 1.31E-08 1.51E-08 1.70E-08 Specification MIN -5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 Status PASS PASS PASS PASS Specification MAX 5.00E-08 8.00E-08 1.00E-07 1.00E-07 Status PASS PASS PASS PASS 50 1/27/2011 2.84E-08 2.83E-08 2.75E-08 2.97E-08 2.87E-08 2.28E-08 2.26E-08 2.30E-08 2.28E-08 2.39E-08 1.15E-08 1.18E-08 24 hr Anneal 60 1/28/2011 2.85E-08 2.83E-08 2.75E-08 2.98E-08 2.87E-08 2.26E-08 2.24E-08 2.28E-08 2.26E-08 2.38E-08 1.15E-08 1.18E-08 168 hr Anneal 70 2/4/2011 2.68E-08 2.67E-08 2.54E-08 2.82E-08 2.70E-08 2.09E-08 2.05E-08 2.09E-08 2.09E-08 2.19E-08 1.16E-08 1.18E-08 2.85E-08 8.10E-10 3.07E-08 2.63E-08 2.86E-08 8.21E-10 3.08E-08 2.63E-08 2.68E-08 9.85E-10 2.95E-08 2.41E-08 2.30E-08 2.28E-08 2.10E-08 5.18E-10 5.39E-10 5.27E-10 2.44E-08 2.43E-08 2.25E-08 2.16E-08 2.13E-08 1.96E-08 -1.25E-07 -1.25E-07 -1.25E-07 PASS PASS PASS 1.25E-07 1.25E-07 1.25E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 130 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 2 @ +5V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.62. Plot of Negative Bias Current 2 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 131 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.62. Raw data for Negative Bias Current 2 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Bias Current 2 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.12E-08 1.40E-08 1.71E-08 2.02E-08 1842 1.29E-08 1.57E-08 1.91E-08 2.26E-08 1843 1.32E-08 1.63E-08 1.97E-08 2.32E-08 1844 1.26E-08 1.55E-08 1.89E-08 2.22E-08 1845 1.26E-08 1.55E-08 1.87E-08 2.21E-08 1846 1.21E-08 1.44E-08 1.65E-08 1.85E-08 1847 1.27E-08 1.49E-08 1.70E-08 1.91E-08 1848 1.25E-08 1.49E-08 1.69E-08 1.89E-08 1849 1.26E-08 1.46E-08 1.67E-08 1.88E-08 1850 1.37E-08 1.64E-08 1.87E-08 2.10E-08 1851 1.25E-08 1.25E-08 1.25E-08 1.24E-08 1852 1.33E-08 1.33E-08 1.32E-08 1.33E-08 Biased Statistics Average Biased 1.25E-08 1.54E-08 1.87E-08 2.20E-08 Std Dev Biased 7.59E-10 8.36E-10 9.67E-10 1.10E-09 Ps90%/90% (+KTL) Biased 1.45E-08 1.77E-08 2.13E-08 2.51E-08 Ps90%/90% (-KTL) Biased 1.04E-08 1.31E-08 1.60E-08 1.90E-08 Un-Biased Statistics Average Un-Biased 1.27E-08 1.50E-08 1.71E-08 1.93E-08 Std Dev Un-Biased 5.79E-10 7.94E-10 9.03E-10 1.00E-09 Ps90%/90% (+KTL) Un-Biased 1.43E-08 1.72E-08 1.96E-08 2.20E-08 Ps90%/90% (-KTL) Un-Biased 1.11E-08 1.29E-08 1.47E-08 1.65E-08 Specification MIN -5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 Status PASS PASS PASS PASS Specification MAX 5.00E-08 8.00E-08 1.00E-07 1.00E-07 Status PASS PASS PASS PASS 50 1/27/2011 2.73E-08 3.02E-08 3.09E-08 2.98E-08 2.95E-08 2.33E-08 2.38E-08 2.36E-08 2.35E-08 2.65E-08 1.24E-08 1.33E-08 24 hr Anneal 60 1/28/2011 2.74E-08 3.02E-08 3.09E-08 2.98E-08 2.95E-08 2.30E-08 2.36E-08 2.34E-08 2.33E-08 2.62E-08 1.24E-08 1.32E-08 168 hr Anneal 70 2/4/2011 2.57E-08 2.87E-08 2.95E-08 2.83E-08 2.81E-08 2.12E-08 2.16E-08 2.17E-08 2.15E-08 2.41E-08 1.24E-08 1.32E-08 2.95E-08 1.36E-09 3.33E-08 2.58E-08 2.96E-08 1.32E-09 3.32E-08 2.59E-08 2.81E-08 1.44E-09 3.20E-08 2.41E-08 2.41E-08 2.39E-08 2.20E-08 1.34E-09 1.32E-09 1.18E-09 2.78E-08 2.75E-08 2.53E-08 2.05E-08 2.03E-08 1.88E-08 -1.25E-07 -1.25E-07 -1.25E-07 PASS PASS PASS 1.25E-07 1.25E-07 1.25E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 132 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 3 @ +5V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.63. Plot of Negative Bias Current 3 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 133 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.63. Raw data for Negative Bias Current 3 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Bias Current 3 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.07E-08 1.35E-08 1.65E-08 1.97E-08 1842 1.21E-08 1.47E-08 1.81E-08 2.13E-08 1843 1.22E-08 1.50E-08 1.82E-08 2.15E-08 1844 1.22E-08 1.51E-08 1.82E-08 2.15E-08 1845 1.22E-08 1.50E-08 1.81E-08 2.13E-08 1846 1.16E-08 1.39E-08 1.59E-08 1.78E-08 1847 1.22E-08 1.44E-08 1.63E-08 1.83E-08 1848 1.27E-08 1.51E-08 1.71E-08 1.92E-08 1849 1.20E-08 1.43E-08 1.63E-08 1.84E-08 1850 1.31E-08 1.57E-08 1.79E-08 2.02E-08 1851 1.21E-08 1.21E-08 1.21E-08 1.21E-08 1852 1.18E-08 1.18E-08 1.19E-08 1.18E-08 Biased Statistics Average Biased 1.19E-08 1.47E-08 1.78E-08 2.11E-08 Std Dev Biased 6.57E-10 6.37E-10 7.24E-10 7.82E-10 Ps90%/90% (+KTL) Biased 1.37E-08 1.64E-08 1.98E-08 2.32E-08 Ps90%/90% (-KTL) Biased 1.01E-08 1.29E-08 1.58E-08 1.89E-08 Un-Biased Statistics Average Un-Biased 1.23E-08 1.47E-08 1.67E-08 1.88E-08 Std Dev Un-Biased 6.00E-10 7.46E-10 8.02E-10 9.22E-10 Ps90%/90% (+KTL) Un-Biased 1.39E-08 1.67E-08 1.89E-08 2.13E-08 Ps90%/90% (-KTL) Un-Biased 1.07E-08 1.26E-08 1.45E-08 1.63E-08 Specification MIN -5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 Status PASS PASS PASS PASS Specification MAX 5.00E-08 8.00E-08 1.00E-07 1.00E-07 Status PASS PASS PASS PASS 50 1/27/2011 2.66E-08 2.85E-08 2.88E-08 2.89E-08 2.87E-08 2.25E-08 2.28E-08 2.38E-08 2.30E-08 2.54E-08 1.21E-08 1.18E-08 24 hr Anneal 60 1/28/2011 2.68E-08 2.86E-08 2.89E-08 2.89E-08 2.87E-08 2.23E-08 2.27E-08 2.36E-08 2.28E-08 2.52E-08 1.21E-08 1.18E-08 168 hr Anneal 70 2/4/2011 2.50E-08 2.70E-08 2.75E-08 2.73E-08 2.71E-08 2.05E-08 2.10E-08 2.18E-08 2.10E-08 2.32E-08 1.21E-08 1.18E-08 2.83E-08 9.33E-10 3.08E-08 2.57E-08 2.84E-08 9.05E-10 3.08E-08 2.59E-08 2.68E-08 9.98E-10 2.95E-08 2.40E-08 2.35E-08 2.33E-08 2.15E-08 1.18E-09 1.15E-09 1.06E-09 2.67E-08 2.65E-08 2.44E-08 2.03E-08 2.02E-08 1.86E-08 -1.25E-07 -1.25E-07 -1.25E-07 PASS PASS PASS 1.25E-07 1.25E-07 1.25E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 134 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 4 @ +5V (A) 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.64. Plot of Negative Bias Current 4 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 135 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.64. Raw data for Negative Bias Current 4 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Bias Current 4 @ +5V (A) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 1.20E-08 1.49E-08 1.83E-08 2.17E-08 1842 1.22E-08 1.53E-08 1.85E-08 2.19E-08 1843 1.12E-08 1.42E-08 1.75E-08 2.09E-08 1844 1.31E-08 1.62E-08 1.95E-08 2.29E-08 1845 1.20E-08 1.49E-08 1.84E-08 2.19E-08 1846 1.23E-08 1.45E-08 1.66E-08 1.87E-08 1847 1.22E-08 1.45E-08 1.66E-08 1.86E-08 1848 1.24E-08 1.47E-08 1.68E-08 1.89E-08 1849 1.19E-08 1.43E-08 1.64E-08 1.86E-08 1850 1.28E-08 1.54E-08 1.75E-08 1.97E-08 1851 1.18E-08 1.18E-08 1.18E-08 1.18E-08 1852 1.29E-08 1.29E-08 1.29E-08 1.28E-08 Biased Statistics Average Biased 1.21E-08 1.51E-08 1.84E-08 2.19E-08 Std Dev Biased 6.86E-10 7.08E-10 7.18E-10 7.33E-10 Ps90%/90% (+KTL) Biased 1.40E-08 1.71E-08 2.04E-08 2.39E-08 Ps90%/90% (-KTL) Biased 1.02E-08 1.32E-08 1.65E-08 1.98E-08 Un-Biased Statistics Average Un-Biased 1.23E-08 1.47E-08 1.68E-08 1.89E-08 Std Dev Un-Biased 3.33E-10 4.36E-10 4.26E-10 4.73E-10 Ps90%/90% (+KTL) Un-Biased 1.32E-08 1.59E-08 1.79E-08 2.02E-08 Ps90%/90% (-KTL) Un-Biased 1.14E-08 1.35E-08 1.56E-08 1.76E-08 Specification MIN -5.00E-08 -8.00E-08 -1.00E-07 -1.00E-07 Status PASS PASS PASS PASS Specification MAX 5.00E-08 8.00E-08 1.00E-07 1.00E-07 Status PASS PASS PASS PASS 50 1/27/2011 2.92E-08 2.92E-08 2.85E-08 3.08E-08 2.97E-08 2.35E-08 2.34E-08 2.36E-08 2.34E-08 2.47E-08 1.18E-08 1.28E-08 24 hr Anneal 60 1/28/2011 2.93E-08 2.93E-08 2.85E-08 3.08E-08 2.97E-08 2.34E-08 2.32E-08 2.34E-08 2.32E-08 2.46E-08 1.18E-08 1.28E-08 168 hr Anneal 70 2/4/2011 2.76E-08 2.76E-08 2.64E-08 2.93E-08 2.78E-08 2.15E-08 2.14E-08 2.14E-08 2.14E-08 2.25E-08 1.18E-08 1.28E-08 2.94E-08 8.57E-10 3.18E-08 2.71E-08 2.95E-08 8.33E-10 3.18E-08 2.72E-08 2.78E-08 1.02E-09 3.06E-08 2.50E-08 2.37E-08 2.35E-08 2.17E-08 5.64E-10 5.83E-10 5.01E-10 2.53E-08 2.51E-08 2.30E-08 2.22E-08 2.19E-08 2.03E-08 -1.25E-07 -1.25E-07 -1.25E-07 PASS PASS PASS 1.25E-07 1.25E-07 1.25E-07 PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 136 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 1 RL=open @ +5V (V) 4.35E+00 4.30E+00 4.25E+00 4.20E+00 4.15E+00 4.10E+00 4.05E+00 4.00E+00 3.95E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.65. Plot of Positive Output Voltage 1 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 137 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.65. Raw data for Positive Output Voltage 1 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 1 RL=open @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 4.30E+00 4.29E+00 4.29E+00 4.30E+00 1842 4.30E+00 4.29E+00 4.29E+00 4.30E+00 1843 4.29E+00 4.29E+00 4.30E+00 4.31E+00 1844 4.29E+00 4.29E+00 4.29E+00 4.29E+00 1845 4.30E+00 4.30E+00 4.30E+00 4.30E+00 1846 4.29E+00 4.29E+00 4.28E+00 4.28E+00 1847 4.28E+00 4.27E+00 4.27E+00 4.27E+00 1848 4.30E+00 4.28E+00 4.28E+00 4.28E+00 1849 4.29E+00 4.29E+00 4.29E+00 4.29E+00 1850 4.29E+00 4.28E+00 4.28E+00 4.28E+00 1851 4.30E+00 4.30E+00 4.29E+00 4.29E+00 1852 4.28E+00 4.28E+00 4.28E+00 4.28E+00 Biased Statistics Average Biased 4.30E+00 4.29E+00 4.29E+00 4.30E+00 Std Dev Biased 4.56E-03 4.77E-03 4.77E-03 5.68E-03 Ps90%/90% (+KTL) Biased 4.31E+00 4.31E+00 4.31E+00 4.31E+00 Ps90%/90% (-KTL) Biased 4.28E+00 4.28E+00 4.28E+00 4.28E+00 Un-Biased Statistics Average Un-Biased 4.29E+00 4.28E+00 4.28E+00 4.28E+00 Std Dev Un-Biased 5.97E-03 6.80E-03 6.46E-03 7.05E-03 Ps90%/90% (+KTL) Un-Biased 4.31E+00 4.30E+00 4.30E+00 4.30E+00 Ps90%/90% (-KTL) Un-Biased 4.27E+00 4.26E+00 4.26E+00 4.26E+00 Specification MIN 4.00E+00 4.00E+00 4.00E+00 4.00E+00 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 138 50 1/27/2011 4.33E+00 4.32E+00 4.33E+00 4.31E+00 4.33E+00 4.29E+00 4.28E+00 4.29E+00 4.30E+00 4.29E+00 4.29E+00 4.28E+00 24 hr Anneal 60 1/28/2011 4.33E+00 4.32E+00 4.33E+00 4.32E+00 4.33E+00 4.29E+00 4.28E+00 4.29E+00 4.30E+00 4.29E+00 4.29E+00 4.28E+00 168 hr Anneal 70 2/4/2011 4.33E+00 4.34E+00 4.33E+00 4.32E+00 4.33E+00 4.30E+00 4.28E+00 4.30E+00 4.31E+00 4.30E+00 4.29E+00 4.28E+00 4.32E+00 4.32E+00 4.33E+00 7.83E-03 7.30E-03 4.12E-03 4.35E+00 4.34E+00 4.34E+00 4.30E+00 4.30E+00 4.32E+00 4.29E+00 6.96E-03 4.31E+00 4.27E+00 4.00E+00 PASS 4.29E+00 7.27E-03 4.31E+00 4.27E+00 4.00E+00 PASS 4.30E+00 7.77E-03 4.32E+00 4.28E+00 4.00E+00 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 2 RL=open @ +5V (V) 4.35E+00 4.30E+00 4.25E+00 4.20E+00 4.15E+00 4.10E+00 4.05E+00 4.00E+00 3.95E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.66. Plot of Positive Output Voltage 2 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 139 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.66. Raw data for Positive Output Voltage 2 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 2 RL=open @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 4.28E+00 4.28E+00 4.28E+00 4.29E+00 1842 4.28E+00 4.28E+00 4.28E+00 4.28E+00 1843 4.28E+00 4.28E+00 4.27E+00 4.28E+00 1844 4.28E+00 4.27E+00 4.27E+00 4.28E+00 1845 4.28E+00 4.27E+00 4.27E+00 4.28E+00 1846 4.28E+00 4.27E+00 4.27E+00 4.27E+00 1847 4.28E+00 4.27E+00 4.26E+00 4.27E+00 1848 4.28E+00 4.27E+00 4.26E+00 4.27E+00 1849 4.28E+00 4.27E+00 4.27E+00 4.27E+00 1850 4.27E+00 4.27E+00 4.26E+00 4.26E+00 1851 4.28E+00 4.28E+00 4.28E+00 4.28E+00 1852 4.27E+00 4.27E+00 4.27E+00 4.27E+00 Biased Statistics Average Biased 4.28E+00 4.28E+00 4.27E+00 4.28E+00 Std Dev Biased 1.64E-03 3.51E-03 3.08E-03 3.94E-03 Ps90%/90% (+KTL) Biased 4.28E+00 4.29E+00 4.28E+00 4.29E+00 Ps90%/90% (-KTL) Biased 4.27E+00 4.27E+00 4.27E+00 4.27E+00 Un-Biased Statistics Average Un-Biased 4.28E+00 4.27E+00 4.27E+00 4.27E+00 Std Dev Un-Biased 2.19E-03 2.65E-03 3.13E-03 2.70E-03 Ps90%/90% (+KTL) Un-Biased 4.28E+00 4.28E+00 4.27E+00 4.27E+00 Ps90%/90% (-KTL) Un-Biased 4.27E+00 4.26E+00 4.26E+00 4.26E+00 Specification MIN 4.00E+00 4.00E+00 4.00E+00 4.00E+00 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 140 50 1/27/2011 4.30E+00 4.29E+00 4.30E+00 4.29E+00 4.29E+00 4.28E+00 4.27E+00 4.27E+00 4.28E+00 4.27E+00 4.28E+00 4.27E+00 24 hr Anneal 60 1/28/2011 4.30E+00 4.29E+00 4.30E+00 4.29E+00 4.29E+00 4.28E+00 4.27E+00 4.27E+00 4.28E+00 4.27E+00 4.28E+00 4.27E+00 168 hr Anneal 70 2/4/2011 4.32E+00 4.31E+00 4.31E+00 4.31E+00 4.30E+00 4.29E+00 4.28E+00 4.28E+00 4.28E+00 4.27E+00 4.28E+00 4.27E+00 4.30E+00 4.30E+00 4.31E+00 5.52E-03 5.52E-03 7.40E-03 4.31E+00 4.31E+00 4.33E+00 4.28E+00 4.28E+00 4.29E+00 4.27E+00 3.36E-03 4.28E+00 4.27E+00 4.00E+00 PASS 4.27E+00 3.32E-03 4.28E+00 4.26E+00 4.00E+00 PASS 4.28E+00 4.09E-03 4.29E+00 4.27E+00 4.00E+00 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 3 RL=open @ +5V (V) 4.35E+00 4.30E+00 4.25E+00 4.20E+00 4.15E+00 4.10E+00 4.05E+00 4.00E+00 3.95E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.67. Plot of Positive Output Voltage 3 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 141 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.67. Raw data for Positive Output Voltage 3 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 3 RL=open @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 4.29E+00 4.29E+00 4.29E+00 4.30E+00 1842 4.29E+00 4.30E+00 4.29E+00 4.30E+00 1843 4.29E+00 4.29E+00 4.29E+00 4.29E+00 1844 4.29E+00 4.29E+00 4.28E+00 4.29E+00 1845 4.29E+00 4.29E+00 4.28E+00 4.29E+00 1846 4.29E+00 4.28E+00 4.28E+00 4.28E+00 1847 4.29E+00 4.28E+00 4.27E+00 4.28E+00 1848 4.29E+00 4.28E+00 4.28E+00 4.28E+00 1849 4.29E+00 4.28E+00 4.28E+00 4.28E+00 1850 4.29E+00 4.27E+00 4.27E+00 4.28E+00 1851 4.30E+00 4.30E+00 4.29E+00 4.29E+00 1852 4.28E+00 4.28E+00 4.28E+00 4.28E+00 Biased Statistics Average Biased 4.29E+00 4.29E+00 4.29E+00 4.29E+00 Std Dev Biased 1.64E-03 4.55E-03 4.22E-03 5.59E-03 Ps90%/90% (+KTL) Biased 4.30E+00 4.30E+00 4.30E+00 4.31E+00 Ps90%/90% (-KTL) Biased 4.29E+00 4.28E+00 4.28E+00 4.28E+00 Un-Biased Statistics Average Un-Biased 4.29E+00 4.28E+00 4.28E+00 4.28E+00 Std Dev Un-Biased 1.41E-03 2.86E-03 2.41E-03 2.55E-03 Ps90%/90% (+KTL) Un-Biased 4.29E+00 4.29E+00 4.28E+00 4.28E+00 Ps90%/90% (-KTL) Un-Biased 4.29E+00 4.27E+00 4.27E+00 4.27E+00 Specification MIN 4.00E+00 4.00E+00 4.00E+00 4.00E+00 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 142 50 1/27/2011 4.33E+00 4.32E+00 4.32E+00 4.32E+00 4.31E+00 4.29E+00 4.28E+00 4.29E+00 4.29E+00 4.28E+00 4.29E+00 4.28E+00 24 hr Anneal 60 1/28/2011 4.33E+00 4.32E+00 4.32E+00 4.32E+00 4.31E+00 4.29E+00 4.28E+00 4.29E+00 4.29E+00 4.28E+00 4.29E+00 4.28E+00 168 hr Anneal 70 2/4/2011 4.33E+00 4.33E+00 4.33E+00 4.32E+00 4.33E+00 4.30E+00 4.29E+00 4.29E+00 4.29E+00 4.29E+00 4.29E+00 4.28E+00 4.32E+00 4.32E+00 4.33E+00 6.99E-03 7.19E-03 3.63E-03 4.34E+00 4.34E+00 4.34E+00 4.30E+00 4.30E+00 4.32E+00 4.29E+00 3.35E-03 4.30E+00 4.28E+00 4.00E+00 PASS 4.29E+00 3.51E-03 4.30E+00 4.28E+00 4.00E+00 PASS 4.29E+00 4.60E-03 4.31E+00 4.28E+00 4.00E+00 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 4 RL=open @ +5V (V) 4.35E+00 4.30E+00 4.25E+00 4.20E+00 4.15E+00 4.10E+00 4.05E+00 4.00E+00 3.95E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.68. Plot of Positive Output Voltage 4 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 143 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.68. Raw data for Positive Output Voltage 4 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 4 RL=open @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 4.28E+00 4.28E+00 4.28E+00 4.28E+00 1842 4.29E+00 4.28E+00 4.28E+00 4.28E+00 1843 4.28E+00 4.28E+00 4.28E+00 4.29E+00 1844 4.28E+00 4.28E+00 4.27E+00 4.28E+00 1845 4.28E+00 4.29E+00 4.28E+00 4.29E+00 1846 4.27E+00 4.27E+00 4.27E+00 4.27E+00 1847 4.28E+00 4.26E+00 4.26E+00 4.26E+00 1848 4.29E+00 4.28E+00 4.27E+00 4.27E+00 1849 4.28E+00 4.27E+00 4.27E+00 4.27E+00 1850 4.28E+00 4.27E+00 4.27E+00 4.27E+00 1851 4.28E+00 4.28E+00 4.28E+00 4.28E+00 1852 4.27E+00 4.27E+00 4.27E+00 4.27E+00 Biased Statistics Average Biased 4.28E+00 4.28E+00 4.28E+00 4.28E+00 Std Dev Biased 3.97E-03 3.70E-03 4.10E-03 4.76E-03 Ps90%/90% (+KTL) Biased 4.29E+00 4.29E+00 4.29E+00 4.30E+00 Ps90%/90% (-KTL) Biased 4.27E+00 4.27E+00 4.27E+00 4.27E+00 Un-Biased Statistics Average Un-Biased 4.28E+00 4.27E+00 4.27E+00 4.27E+00 Std Dev Un-Biased 4.76E-03 4.38E-03 4.04E-03 4.04E-03 Ps90%/90% (+KTL) Un-Biased 4.29E+00 4.28E+00 4.28E+00 4.28E+00 Ps90%/90% (-KTL) Un-Biased 4.27E+00 4.26E+00 4.26E+00 4.26E+00 Specification MIN 4.00E+00 4.00E+00 4.00E+00 4.00E+00 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 144 50 1/27/2011 4.30E+00 4.30E+00 4.31E+00 4.29E+00 4.30E+00 4.28E+00 4.27E+00 4.28E+00 4.28E+00 4.28E+00 4.28E+00 4.27E+00 24 hr Anneal 60 1/28/2011 4.30E+00 4.30E+00 4.31E+00 4.29E+00 4.30E+00 4.28E+00 4.27E+00 4.28E+00 4.28E+00 4.28E+00 4.28E+00 4.27E+00 168 hr Anneal 70 2/4/2011 4.31E+00 4.31E+00 4.33E+00 4.30E+00 4.31E+00 4.28E+00 4.28E+00 4.29E+00 4.29E+00 4.28E+00 4.28E+00 4.27E+00 4.30E+00 4.30E+00 4.31E+00 6.91E-03 7.21E-03 1.01E-02 4.32E+00 4.32E+00 4.34E+00 4.28E+00 4.28E+00 4.29E+00 4.28E+00 4.04E-03 4.29E+00 4.27E+00 4.00E+00 PASS 4.28E+00 3.90E-03 4.29E+00 4.27E+00 4.00E+00 PASS 4.28E+00 4.34E-03 4.29E+00 4.27E+00 4.00E+00 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 1 RL=600 @ +5V (V) 4.50E+00 4.00E+00 3.50E+00 3.00E+00 2.50E+00 2.00E+00 1.50E+00 1.00E+00 5.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.69. Plot of Positive Output Voltage 1 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 145 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.69. Raw data for Positive Output Voltage 1 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 1 RL=600 @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1842 3.86E+00 3.86E+00 3.85E+00 3.85E+00 1843 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1844 3.83E+00 3.83E+00 3.83E+00 3.83E+00 1845 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1846 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1847 3.83E+00 3.84E+00 3.83E+00 3.83E+00 1848 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1849 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1850 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1851 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1852 3.85E+00 3.85E+00 3.85E+00 3.85E+00 Biased Statistics Average Biased 3.85E+00 3.85E+00 3.84E+00 3.84E+00 Std Dev Biased 1.00E-02 1.05E-02 1.05E-02 1.03E-02 Ps90%/90% (+KTL) Biased 3.88E+00 3.88E+00 3.87E+00 3.87E+00 Ps90%/90% (-KTL) Biased 3.82E+00 3.82E+00 3.82E+00 3.82E+00 Un-Biased Statistics Average Un-Biased 3.85E+00 3.85E+00 3.85E+00 3.84E+00 Std Dev Un-Biased 8.26E-03 8.20E-03 8.32E-03 8.35E-03 Ps90%/90% (+KTL) Un-Biased 3.87E+00 3.87E+00 3.87E+00 3.87E+00 Ps90%/90% (-KTL) Un-Biased 3.83E+00 3.83E+00 3.82E+00 3.82E+00 Specification MIN 3.40E+00 3.40E+00 3.20E+00 3.20E+00 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 146 50 1/27/2011 3.85E+00 3.85E+00 3.85E+00 3.83E+00 3.85E+00 3.85E+00 3.83E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 24 hr Anneal 60 1/28/2011 3.85E+00 3.85E+00 3.85E+00 3.83E+00 3.85E+00 3.85E+00 3.83E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 168 hr Anneal 70 2/4/2011 3.85E+00 3.85E+00 3.85E+00 3.83E+00 3.85E+00 3.85E+00 3.83E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00 1.01E-02 1.01E-02 1.06E-02 3.87E+00 3.87E+00 3.87E+00 3.82E+00 3.82E+00 3.81E+00 3.84E+00 8.58E-03 3.87E+00 3.82E+00 3.00E+00 PASS 3.84E+00 8.58E-03 3.87E+00 3.82E+00 3.00E+00 PASS 3.84E+00 8.26E-03 3.87E+00 3.82E+00 3.40E+00 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 2 RL=600 @ +5V (V) 4.50E+00 4.00E+00 3.50E+00 3.00E+00 2.50E+00 2.00E+00 1.50E+00 1.00E+00 5.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.70. Plot of Positive Output Voltage 2 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 147 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.70. Raw data for Positive Output Voltage 2 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 2 RL=600 @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 3.86E+00 3.86E+00 3.86E+00 3.85E+00 1842 3.86E+00 3.86E+00 3.85E+00 3.85E+00 1843 3.85E+00 3.85E+00 3.84E+00 3.84E+00 1844 3.84E+00 3.84E+00 3.84E+00 3.84E+00 1845 3.85E+00 3.85E+00 3.84E+00 3.84E+00 1846 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1847 3.85E+00 3.85E+00 3.84E+00 3.84E+00 1848 3.85E+00 3.85E+00 3.84E+00 3.84E+00 1849 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1850 3.86E+00 3.86E+00 3.86E+00 3.85E+00 1851 3.86E+00 3.86E+00 3.86E+00 3.86E+00 1852 3.85E+00 3.85E+00 3.85E+00 3.84E+00 Biased Statistics Average Biased 3.85E+00 3.85E+00 3.85E+00 3.85E+00 Std Dev Biased 7.75E-03 7.53E-03 7.83E-03 7.69E-03 Ps90%/90% (+KTL) Biased 3.87E+00 3.87E+00 3.87E+00 3.87E+00 Ps90%/90% (-KTL) Biased 3.83E+00 3.83E+00 3.82E+00 3.82E+00 Un-Biased Statistics Average Un-Biased 3.85E+00 3.85E+00 3.85E+00 3.85E+00 Std Dev Un-Biased 5.32E-03 5.48E-03 5.59E-03 5.22E-03 Ps90%/90% (+KTL) Un-Biased 3.86E+00 3.87E+00 3.86E+00 3.86E+00 Ps90%/90% (-KTL) Un-Biased 3.84E+00 3.84E+00 3.83E+00 3.83E+00 Specification MIN 3.40E+00 3.40E+00 3.20E+00 3.20E+00 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 148 50 1/27/2011 3.85E+00 3.85E+00 3.84E+00 3.83E+00 3.84E+00 3.85E+00 3.84E+00 3.84E+00 3.85E+00 3.85E+00 3.86E+00 3.85E+00 24 hr Anneal 60 1/28/2011 3.85E+00 3.85E+00 3.84E+00 3.83E+00 3.84E+00 3.85E+00 3.84E+00 3.84E+00 3.85E+00 3.85E+00 3.86E+00 3.84E+00 168 hr Anneal 70 2/4/2011 3.85E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00 3.85E+00 3.84E+00 3.84E+00 3.85E+00 3.85E+00 3.86E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00 7.83E-03 8.50E-03 7.99E-03 3.87E+00 3.87E+00 3.87E+00 3.82E+00 3.82E+00 3.82E+00 3.85E+00 5.68E-03 3.86E+00 3.83E+00 3.00E+00 PASS 3.85E+00 5.32E-03 3.86E+00 3.83E+00 3.00E+00 PASS 3.85E+00 5.61E-03 3.86E+00 3.83E+00 3.40E+00 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 3 RL=600 @ +5V (V) 4.50E+00 4.00E+00 3.50E+00 3.00E+00 2.50E+00 2.00E+00 1.50E+00 1.00E+00 5.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.71. Plot of Positive Output Voltage 3 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 149 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.71. Raw data for Positive Output Voltage 3 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 3 RL=600 @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1842 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1843 3.84E+00 3.84E+00 3.84E+00 3.84E+00 1844 3.83E+00 3.83E+00 3.83E+00 3.83E+00 1845 3.84E+00 3.84E+00 3.83E+00 3.83E+00 1846 3.85E+00 3.85E+00 3.84E+00 3.84E+00 1847 3.84E+00 3.84E+00 3.83E+00 3.83E+00 1848 3.84E+00 3.84E+00 3.83E+00 3.83E+00 1849 3.84E+00 3.84E+00 3.84E+00 3.84E+00 1850 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1851 3.85E+00 3.85E+00 3.85E+00 3.85E+00 1852 3.84E+00 3.84E+00 3.84E+00 3.84E+00 Biased Statistics Average Biased 3.84E+00 3.84E+00 3.84E+00 3.84E+00 Std Dev Biased 8.59E-03 7.82E-03 7.92E-03 7.54E-03 Ps90%/90% (+KTL) Biased 3.87E+00 3.86E+00 3.86E+00 3.86E+00 Ps90%/90% (-KTL) Biased 3.82E+00 3.82E+00 3.82E+00 3.82E+00 Un-Biased Statistics Average Un-Biased 3.84E+00 3.84E+00 3.84E+00 3.84E+00 Std Dev Un-Biased 6.69E-03 6.83E-03 6.72E-03 6.88E-03 Ps90%/90% (+KTL) Un-Biased 3.86E+00 3.86E+00 3.86E+00 3.86E+00 Ps90%/90% (-KTL) Un-Biased 3.82E+00 3.82E+00 3.82E+00 3.82E+00 Specification MIN 3.40E+00 3.40E+00 3.20E+00 3.20E+00 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 150 50 1/27/2011 3.85E+00 3.84E+00 3.83E+00 3.83E+00 3.83E+00 3.84E+00 3.83E+00 3.83E+00 3.84E+00 3.85E+00 3.85E+00 3.84E+00 24 hr Anneal 60 1/28/2011 3.85E+00 3.84E+00 3.83E+00 3.83E+00 3.83E+00 3.84E+00 3.83E+00 3.83E+00 3.84E+00 3.85E+00 3.85E+00 3.84E+00 168 hr Anneal 70 2/4/2011 3.85E+00 3.84E+00 3.83E+00 3.83E+00 3.83E+00 3.84E+00 3.83E+00 3.83E+00 3.84E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00 7.92E-03 8.35E-03 8.35E-03 3.86E+00 3.86E+00 3.86E+00 3.81E+00 3.81E+00 3.81E+00 3.84E+00 7.02E-03 3.86E+00 3.82E+00 3.00E+00 PASS 3.84E+00 7.06E-03 3.86E+00 3.82E+00 3.00E+00 PASS 3.84E+00 6.93E-03 3.86E+00 3.82E+00 3.40E+00 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased Positive Output Voltage 4 RL=600 @ +5V (V) 4.50E+00 4.00E+00 3.50E+00 3.00E+00 2.50E+00 2.00E+00 1.50E+00 1.00E+00 5.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.72. Plot of Positive Output Voltage 4 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 151 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.72. Raw data for Positive Output Voltage 4 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Output Voltage 4 RL=600 @ +5V (V) Device 0 10 20 30 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1841 3.86E+00 3.86E+00 3.86E+00 3.86E+00 1842 3.86E+00 3.86E+00 3.86E+00 3.86E+00 1843 3.86E+00 3.86E+00 3.86E+00 3.86E+00 1844 3.84E+00 3.84E+00 3.84E+00 3.84E+00 1845 3.86E+00 3.86E+00 3.86E+00 3.86E+00 1846 3.86E+00 3.86E+00 3.86E+00 3.86E+00 1847 3.84E+00 3.84E+00 3.84E+00 3.84E+00 1848 3.86E+00 3.86E+00 3.86E+00 3.85E+00 1849 3.86E+00 3.86E+00 3.86E+00 3.86E+00 1850 3.86E+00 3.86E+00 3.86E+00 3.85E+00 1851 3.86E+00 3.86E+00 3.85E+00 3.85E+00 1852 3.86E+00 3.86E+00 3.86E+00 3.86E+00 Biased Statistics Average Biased 3.86E+00 3.86E+00 3.85E+00 3.85E+00 Std Dev Biased 8.71E-03 8.56E-03 8.79E-03 8.56E-03 Ps90%/90% (+KTL) Biased 3.88E+00 3.88E+00 3.88E+00 3.88E+00 Ps90%/90% (-KTL) Biased 3.83E+00 3.83E+00 3.83E+00 3.83E+00 Un-Biased Statistics Average Un-Biased 3.86E+00 3.86E+00 3.85E+00 3.85E+00 Std Dev Un-Biased 8.44E-03 8.14E-03 8.23E-03 8.32E-03 Ps90%/90% (+KTL) Un-Biased 3.88E+00 3.88E+00 3.88E+00 3.87E+00 Ps90%/90% (-KTL) Un-Biased 3.83E+00 3.83E+00 3.83E+00 3.83E+00 Specification MIN 3.40E+00 3.40E+00 3.20E+00 3.20E+00 Status PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 152 50 1/27/2011 3.86E+00 3.85E+00 3.85E+00 3.84E+00 3.86E+00 3.86E+00 3.84E+00 3.85E+00 3.86E+00 3.85E+00 3.85E+00 3.86E+00 24 hr Anneal 60 1/28/2011 3.86E+00 3.85E+00 3.85E+00 3.84E+00 3.86E+00 3.86E+00 3.84E+00 3.85E+00 3.86E+00 3.85E+00 3.85E+00 3.86E+00 168 hr Anneal 70 2/4/2011 3.86E+00 3.85E+00 3.85E+00 3.84E+00 3.86E+00 3.86E+00 3.84E+00 3.85E+00 3.86E+00 3.85E+00 3.85E+00 3.86E+00 3.85E+00 3.85E+00 3.85E+00 8.64E-03 8.93E-03 8.71E-03 3.87E+00 3.88E+00 3.88E+00 3.83E+00 3.83E+00 3.83E+00 3.85E+00 8.58E-03 3.87E+00 3.83E+00 3.00E+00 PASS 3.85E+00 8.51E-03 3.87E+00 3.83E+00 3.00E+00 PASS 3.85E+00 8.88E-03 3.88E+00 3.83E+00 3.40E+00 PASS ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 1 RL=open @ +5V (V) 4.50E-02 4.00E-02 3.50E-02 3.00E-02 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.73. Plot of Output Voltage Low 1 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 153 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.73. Raw data for Output Voltage Low 1 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 1 RL=open @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 1.41E-02 1.41E-02 1.41E-02 1.40E-02 1.42E-02 1.42E-02 1.42E-02 1842 1.41E-02 1.42E-02 1.42E-02 1.41E-02 1.42E-02 1.41E-02 1.41E-02 1843 1.41E-02 1.40E-02 1.41E-02 1.42E-02 1.44E-02 1.43E-02 1.42E-02 1844 1.38E-02 1.39E-02 1.37E-02 1.40E-02 1.38E-02 1.38E-02 1.38E-02 1845 1.39E-02 1.40E-02 1.40E-02 1.40E-02 1.41E-02 1.42E-02 1.40E-02 1846 1.40E-02 1.41E-02 1.40E-02 1.40E-02 1.42E-02 1.43E-02 1.40E-02 1847 1.37E-02 1.39E-02 1.38E-02 1.38E-02 1.39E-02 1.39E-02 1.38E-02 1848 1.41E-02 1.41E-02 1.42E-02 1.44E-02 1.43E-02 1.40E-02 1.42E-02 1849 1.41E-02 1.41E-02 1.41E-02 1.42E-02 1.41E-02 1.42E-02 1.42E-02 1850 1.38E-02 1.39E-02 1.38E-02 1.39E-02 1.41E-02 1.40E-02 1.41E-02 1851 1.39E-02 1.39E-02 1.38E-02 1.39E-02 1.39E-02 1.39E-02 1.39E-02 1852 1.39E-02 1.40E-02 1.38E-02 1.38E-02 1.38E-02 1.39E-02 1.39E-02 Biased Statistics Average Biased 1.40E-02 1.40E-02 1.40E-02 1.41E-02 1.41E-02 1.41E-02 1.41E-02 Std Dev Biased 1.41E-04 1.14E-04 1.92E-04 8.94E-05 2.19E-04 1.92E-04 1.67E-04 Ps90%/90% (+KTL) Biased 1.44E-02 1.44E-02 1.45E-02 1.43E-02 1.47E-02 1.46E-02 1.45E-02 Ps90%/90% (-KTL) Biased 1.36E-02 1.37E-02 1.35E-02 1.38E-02 1.35E-02 1.36E-02 1.36E-02 Un-Biased Statistics Average Un-Biased 1.39E-02 1.40E-02 1.40E-02 1.41E-02 1.41E-02 1.41E-02 1.41E-02 Std Dev Un-Biased 1.82E-04 1.10E-04 1.79E-04 2.41E-04 1.48E-04 1.64E-04 1.67E-04 Ps90%/90% (+KTL) Un-Biased 1.44E-02 1.43E-02 1.45E-02 1.47E-02 1.45E-02 1.45E-02 1.45E-02 Ps90%/90% (-KTL) Un-Biased 1.34E-02 1.37E-02 1.35E-02 1.34E-02 1.37E-02 1.36E-02 1.36E-02 Specification MAX 2.50E-02 2.50E-02 3.00E-02 3.00E-02 4.00E-02 4.00E-02 4.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 154 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 2 RL=open @ +5V (V) 4.50E-02 4.00E-02 3.50E-02 3.00E-02 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.74. Plot of Output Voltage Low 2 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 155 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.74. Raw data for Output Voltage Low 2 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 2 RL=open @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 1.40E-02 1.41E-02 1.40E-02 1.40E-02 1.40E-02 1.41E-02 1.40E-02 1842 1.41E-02 1.41E-02 1.39E-02 1.38E-02 1.40E-02 1.41E-02 1.40E-02 1843 1.37E-02 1.37E-02 1.37E-02 1.37E-02 1.38E-02 1.37E-02 1.37E-02 1844 1.37E-02 1.37E-02 1.38E-02 1.37E-02 1.39E-02 1.37E-02 1.38E-02 1845 1.38E-02 1.38E-02 1.38E-02 1.38E-02 1.37E-02 1.38E-02 1.39E-02 1846 1.40E-02 1.39E-02 1.40E-02 1.38E-02 1.41E-02 1.41E-02 1.40E-02 1847 1.38E-02 1.39E-02 1.38E-02 1.39E-02 1.39E-02 1.40E-02 1.40E-02 1848 1.37E-02 1.39E-02 1.37E-02 1.38E-02 1.40E-02 1.40E-02 1.39E-02 1849 1.37E-02 1.39E-02 1.38E-02 1.39E-02 1.41E-02 1.39E-02 1.40E-02 1850 1.37E-02 1.39E-02 1.36E-02 1.37E-02 1.39E-02 1.39E-02 1.39E-02 1851 1.40E-02 1.41E-02 1.39E-02 1.38E-02 1.38E-02 1.39E-02 1.38E-02 1852 1.38E-02 1.38E-02 1.38E-02 1.38E-02 1.37E-02 1.37E-02 1.38E-02 Biased Statistics Average Biased 1.39E-02 1.39E-02 1.38E-02 1.38E-02 1.39E-02 1.39E-02 1.39E-02 Std Dev Biased 1.82E-04 2.05E-04 1.14E-04 1.22E-04 1.30E-04 2.05E-04 1.30E-04 Ps90%/90% (+KTL) Biased 1.44E-02 1.44E-02 1.42E-02 1.41E-02 1.42E-02 1.44E-02 1.42E-02 Ps90%/90% (-KTL) Biased 1.34E-02 1.33E-02 1.35E-02 1.35E-02 1.35E-02 1.33E-02 1.35E-02 Un-Biased Statistics Average Un-Biased 1.38E-02 1.39E-02 1.38E-02 1.38E-02 1.40E-02 1.40E-02 1.40E-02 Std Dev Un-Biased 1.30E-04 0.00E+00 1.48E-04 8.37E-05 1.00E-04 8.37E-05 5.48E-05 Ps90%/90% (+KTL) Un-Biased 1.41E-02 1.39E-02 1.42E-02 1.40E-02 1.43E-02 1.42E-02 1.41E-02 Ps90%/90% (-KTL) Un-Biased 1.34E-02 1.39E-02 1.34E-02 1.36E-02 1.37E-02 1.38E-02 1.38E-02 Specification MAX 2.50E-02 2.50E-02 3.00E-02 3.00E-02 4.00E-02 4.00E-02 4.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 156 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 3 RL=open @ +5V (V) 4.50E-02 4.00E-02 3.50E-02 3.00E-02 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.75. Plot of Output Voltage Low 3 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 157 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.75. Raw data for Output Voltage Low 3 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 3 RL=open @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 1.41E-02 1.40E-02 1.41E-02 1.42E-02 1.41E-02 1.42E-02 1.41E-02 1842 1.41E-02 1.40E-02 1.41E-02 1.41E-02 1.41E-02 1.41E-02 1.42E-02 1843 1.38E-02 1.38E-02 1.39E-02 1.37E-02 1.39E-02 1.38E-02 1.39E-02 1844 1.38E-02 1.39E-02 1.38E-02 1.38E-02 1.39E-02 1.38E-02 1.39E-02 1845 1.39E-02 1.39E-02 1.40E-02 1.39E-02 1.40E-02 1.39E-02 1.40E-02 1846 1.39E-02 1.38E-02 1.39E-02 1.39E-02 1.40E-02 1.40E-02 1.41E-02 1847 1.37E-02 1.39E-02 1.38E-02 1.39E-02 1.40E-02 1.41E-02 1.40E-02 1848 1.37E-02 1.40E-02 1.39E-02 1.38E-02 1.42E-02 1.38E-02 1.38E-02 1849 1.40E-02 1.39E-02 1.38E-02 1.39E-02 1.41E-02 1.40E-02 1.39E-02 1850 1.38E-02 1.39E-02 1.37E-02 1.38E-02 1.42E-02 1.41E-02 1.40E-02 1851 1.40E-02 1.38E-02 1.38E-02 1.39E-02 1.39E-02 1.41E-02 1.39E-02 1852 1.38E-02 1.40E-02 1.37E-02 1.37E-02 1.37E-02 1.38E-02 1.40E-02 Biased Statistics Average Biased 1.39E-02 1.39E-02 1.40E-02 1.39E-02 1.40E-02 1.40E-02 1.40E-02 Std Dev Biased 1.52E-04 8.37E-05 1.30E-04 2.07E-04 1.00E-04 1.82E-04 1.30E-04 Ps90%/90% (+KTL) Biased 1.44E-02 1.41E-02 1.43E-02 1.45E-02 1.43E-02 1.45E-02 1.44E-02 Ps90%/90% (-KTL) Biased 1.35E-02 1.37E-02 1.36E-02 1.34E-02 1.37E-02 1.35E-02 1.37E-02 Un-Biased Statistics Average Un-Biased 1.38E-02 1.39E-02 1.38E-02 1.39E-02 1.41E-02 1.40E-02 1.40E-02 Std Dev Un-Biased 1.30E-04 7.07E-05 8.37E-05 5.48E-05 1.00E-04 1.22E-04 1.14E-04 Ps90%/90% (+KTL) Un-Biased 1.42E-02 1.41E-02 1.40E-02 1.40E-02 1.44E-02 1.43E-02 1.43E-02 Ps90%/90% (-KTL) Un-Biased 1.35E-02 1.37E-02 1.36E-02 1.37E-02 1.38E-02 1.37E-02 1.36E-02 Specification MAX 2.50E-02 2.50E-02 3.00E-02 3.00E-02 4.00E-02 4.00E-02 4.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 158 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 4 RL=open @ +5V (V) 4.50E-02 4.00E-02 3.50E-02 3.00E-02 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.76. Plot of Output Voltage Low 4 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 159 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.76. Raw data for Output Voltage Low 4 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 4 RL=open @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 1.40E-02 1.41E-02 1.41E-02 1.39E-02 1.39E-02 1.41E-02 1.41E-02 1842 1.42E-02 1.40E-02 1.41E-02 1.41E-02 1.41E-02 1.41E-02 1.41E-02 1843 1.42E-02 1.43E-02 1.41E-02 1.41E-02 1.42E-02 1.41E-02 1.40E-02 1844 1.37E-02 1.38E-02 1.35E-02 1.36E-02 1.38E-02 1.37E-02 1.37E-02 1845 1.40E-02 1.41E-02 1.40E-02 1.40E-02 1.42E-02 1.40E-02 1.42E-02 1846 1.40E-02 1.40E-02 1.40E-02 1.42E-02 1.43E-02 1.41E-02 1.42E-02 1847 1.37E-02 1.37E-02 1.38E-02 1.38E-02 1.37E-02 1.38E-02 1.39E-02 1848 1.41E-02 1.40E-02 1.42E-02 1.43E-02 1.44E-02 1.42E-02 1.43E-02 1849 1.41E-02 1.41E-02 1.41E-02 1.41E-02 1.42E-02 1.42E-02 1.43E-02 1850 1.39E-02 1.39E-02 1.40E-02 1.40E-02 1.39E-02 1.40E-02 1.41E-02 1851 1.40E-02 1.40E-02 1.38E-02 1.39E-02 1.39E-02 1.39E-02 1.39E-02 1852 1.39E-02 1.39E-02 1.38E-02 1.38E-02 1.38E-02 1.38E-02 1.39E-02 Biased Statistics Average Biased 1.40E-02 1.41E-02 1.40E-02 1.39E-02 1.40E-02 1.40E-02 1.40E-02 Std Dev Biased 2.05E-04 1.82E-04 2.61E-04 2.07E-04 1.82E-04 1.73E-04 1.92E-04 Ps90%/90% (+KTL) Biased 1.46E-02 1.46E-02 1.47E-02 1.45E-02 1.45E-02 1.45E-02 1.45E-02 Ps90%/90% (-KTL) Biased 1.35E-02 1.36E-02 1.32E-02 1.34E-02 1.35E-02 1.35E-02 1.35E-02 Un-Biased Statistics Average Un-Biased 1.40E-02 1.39E-02 1.40E-02 1.41E-02 1.41E-02 1.41E-02 1.42E-02 Std Dev Un-Biased 1.67E-04 1.52E-04 1.48E-04 1.92E-04 2.92E-04 1.67E-04 1.67E-04 Ps90%/90% (+KTL) Un-Biased 1.44E-02 1.44E-02 1.44E-02 1.46E-02 1.49E-02 1.45E-02 1.46E-02 Ps90%/90% (-KTL) Un-Biased 1.35E-02 1.35E-02 1.36E-02 1.36E-02 1.33E-02 1.36E-02 1.37E-02 Specification MAX 2.50E-02 2.50E-02 3.00E-02 3.00E-02 4.00E-02 4.00E-02 4.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 160 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 1 RL=600 @ +5V (V) 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.77. Plot of Output Voltage Low 1 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 161 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.77. Raw data for Output Voltage Low 1 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 1 RL=600 @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 4.50E-03 4.50E-03 4.60E-03 4.50E-03 4.20E-03 4.20E-03 4.20E-03 1842 4.30E-03 4.30E-03 4.30E-03 4.20E-03 4.20E-03 4.00E-03 4.10E-03 1843 4.60E-03 4.60E-03 4.40E-03 4.30E-03 4.10E-03 4.20E-03 4.10E-03 1844 4.30E-03 4.30E-03 4.30E-03 4.10E-03 4.00E-03 4.00E-03 4.10E-03 1845 4.40E-03 4.40E-03 4.50E-03 4.30E-03 4.30E-03 4.00E-03 4.20E-03 1846 4.50E-03 4.60E-03 4.50E-03 4.40E-03 4.20E-03 4.40E-03 4.30E-03 1847 4.40E-03 4.50E-03 4.60E-03 4.50E-03 4.20E-03 4.50E-03 4.30E-03 1848 4.40E-03 4.50E-03 4.40E-03 4.40E-03 4.20E-03 4.10E-03 4.30E-03 1849 4.50E-03 4.50E-03 4.50E-03 4.50E-03 4.20E-03 4.30E-03 4.30E-03 1850 4.40E-03 4.60E-03 4.50E-03 4.30E-03 4.30E-03 4.30E-03 4.40E-03 1851 4.50E-03 4.40E-03 4.40E-03 4.40E-03 4.20E-03 4.40E-03 4.30E-03 1852 4.50E-03 4.40E-03 4.70E-03 4.50E-03 4.70E-03 4.70E-03 4.60E-03 Biased Statistics Average Biased 4.42E-03 4.42E-03 4.42E-03 4.28E-03 4.16E-03 4.08E-03 4.14E-03 Std Dev Biased 1.30E-04 1.30E-04 1.30E-04 1.48E-04 1.14E-04 1.10E-04 5.48E-05 Ps90%/90% (+KTL) Biased 4.78E-03 4.78E-03 4.78E-03 4.69E-03 4.47E-03 4.38E-03 4.29E-03 Ps90%/90% (-KTL) Biased 4.06E-03 4.06E-03 4.06E-03 3.87E-03 3.85E-03 3.78E-03 3.99E-03 Un-Biased Statistics Average Un-Biased 4.44E-03 4.54E-03 4.50E-03 4.42E-03 4.22E-03 4.32E-03 4.32E-03 Std Dev Un-Biased 5.48E-05 5.48E-05 7.07E-05 8.37E-05 4.47E-05 1.48E-04 4.47E-05 Ps90%/90% (+KTL) Un-Biased 4.59E-03 4.69E-03 4.69E-03 4.65E-03 4.34E-03 4.73E-03 4.44E-03 Ps90%/90% (-KTL) Un-Biased 4.29E-03 4.39E-03 4.31E-03 4.19E-03 4.10E-03 3.91E-03 4.20E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 162 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 2 RL=600 @ +5V (V) 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.78. Plot of Output Voltage Low 2 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 163 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.78. Raw data for Output Voltage Low 2 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 2 RL=600 @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 4.90E-03 5.00E-03 4.80E-03 4.90E-03 4.50E-03 4.50E-03 4.50E-03 1842 4.80E-03 4.60E-03 4.60E-03 4.50E-03 4.30E-03 4.30E-03 4.40E-03 1843 4.60E-03 4.60E-03 4.60E-03 4.60E-03 4.40E-03 4.30E-03 4.30E-03 1844 4.50E-03 4.60E-03 4.70E-03 4.50E-03 4.30E-03 4.30E-03 4.30E-03 1845 4.60E-03 4.60E-03 4.50E-03 4.40E-03 4.30E-03 4.20E-03 4.30E-03 1846 4.90E-03 5.00E-03 4.80E-03 4.80E-03 4.60E-03 4.60E-03 4.60E-03 1847 4.60E-03 4.60E-03 4.70E-03 4.70E-03 4.50E-03 4.40E-03 4.60E-03 1848 4.70E-03 4.70E-03 4.70E-03 4.60E-03 4.50E-03 4.50E-03 4.60E-03 1849 4.70E-03 4.90E-03 4.70E-03 4.70E-03 4.60E-03 4.70E-03 4.60E-03 1850 4.90E-03 5.00E-03 4.90E-03 4.90E-03 4.90E-03 4.80E-03 4.80E-03 1851 4.90E-03 4.70E-03 4.70E-03 4.80E-03 4.70E-03 4.60E-03 4.80E-03 1852 4.80E-03 4.70E-03 4.70E-03 4.70E-03 4.80E-03 4.70E-03 4.90E-03 Biased Statistics Average Biased 4.68E-03 4.68E-03 4.64E-03 4.58E-03 4.36E-03 4.32E-03 4.36E-03 Std Dev Biased 1.64E-04 1.79E-04 1.14E-04 1.92E-04 8.94E-05 1.10E-04 8.94E-05 Ps90%/90% (+KTL) Biased 5.13E-03 5.17E-03 4.95E-03 5.11E-03 4.61E-03 4.62E-03 4.61E-03 Ps90%/90% (-KTL) Biased 4.23E-03 4.19E-03 4.33E-03 4.05E-03 4.11E-03 4.02E-03 4.11E-03 Un-Biased Statistics Average Un-Biased 4.76E-03 4.84E-03 4.76E-03 4.74E-03 4.62E-03 4.60E-03 4.64E-03 Std Dev Un-Biased 1.34E-04 1.82E-04 8.94E-05 1.14E-04 1.64E-04 1.58E-04 8.94E-05 Ps90%/90% (+KTL) Un-Biased 5.13E-03 5.34E-03 5.01E-03 5.05E-03 5.07E-03 5.03E-03 4.89E-03 Ps90%/90% (-KTL) Un-Biased 4.39E-03 4.34E-03 4.51E-03 4.43E-03 4.17E-03 4.17E-03 4.39E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 164 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 4 RL=600 @ +5V (V) 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.79. Plot of Output Voltage Low 4 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 165 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.79. Raw data for Output Voltage Low 4 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 4 RL=600 @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 4.80E-03 4.90E-03 4.90E-03 4.80E-03 4.40E-03 4.60E-03 4.50E-03 1842 4.80E-03 4.70E-03 4.70E-03 4.70E-03 4.50E-03 4.50E-03 4.50E-03 1843 5.10E-03 4.80E-03 4.80E-03 4.90E-03 4.50E-03 4.50E-03 4.50E-03 1844 4.60E-03 4.70E-03 4.60E-03 4.50E-03 4.40E-03 4.40E-03 4.30E-03 1845 4.90E-03 4.90E-03 4.90E-03 4.80E-03 4.50E-03 4.50E-03 4.50E-03 1846 5.10E-03 5.00E-03 5.00E-03 5.00E-03 4.70E-03 4.80E-03 4.70E-03 1847 4.80E-03 4.90E-03 4.80E-03 4.90E-03 4.70E-03 4.80E-03 4.60E-03 1848 4.80E-03 4.80E-03 5.00E-03 4.90E-03 4.60E-03 4.70E-03 4.60E-03 1849 5.10E-03 5.10E-03 5.00E-03 4.80E-03 4.70E-03 4.90E-03 4.80E-03 1850 4.90E-03 5.00E-03 4.90E-03 4.90E-03 4.90E-03 4.80E-03 4.70E-03 1851 4.80E-03 4.80E-03 4.70E-03 4.70E-03 4.80E-03 4.90E-03 4.90E-03 1852 5.00E-03 5.00E-03 5.00E-03 5.00E-03 5.00E-03 5.00E-03 4.90E-03 Biased Statistics Average Biased 4.84E-03 4.80E-03 4.78E-03 4.74E-03 4.46E-03 4.50E-03 4.46E-03 Std Dev Biased 1.82E-04 1.00E-04 1.30E-04 1.52E-04 5.48E-05 7.07E-05 8.94E-05 Ps90%/90% (+KTL) Biased 5.34E-03 5.07E-03 5.14E-03 5.16E-03 4.61E-03 4.69E-03 4.71E-03 Ps90%/90% (-KTL) Biased 4.34E-03 4.53E-03 4.42E-03 4.32E-03 4.31E-03 4.31E-03 4.21E-03 Un-Biased Statistics Average Un-Biased 4.94E-03 4.96E-03 4.94E-03 4.90E-03 4.72E-03 4.80E-03 4.68E-03 Std Dev Un-Biased 1.52E-04 1.14E-04 8.94E-05 7.07E-05 1.10E-04 7.07E-05 8.37E-05 Ps90%/90% (+KTL) Un-Biased 5.36E-03 5.27E-03 5.19E-03 5.09E-03 5.02E-03 4.99E-03 4.91E-03 Ps90%/90% (-KTL) Un-Biased 4.52E-03 4.65E-03 4.69E-03 4.71E-03 4.42E-03 4.61E-03 4.45E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 166 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 3 RL=600 @ +5V (V) 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.80. Plot of Output Voltage Low 3 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 167 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.80. Raw data for Output Voltage Low 3 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 3 RL=600 @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 4.70E-03 4.70E-03 4.50E-03 4.50E-03 4.20E-03 4.30E-03 4.10E-03 1842 4.50E-03 4.40E-03 4.30E-03 4.50E-03 4.20E-03 4.10E-03 4.10E-03 1843 4.40E-03 4.60E-03 4.30E-03 4.40E-03 4.30E-03 4.20E-03 4.20E-03 1844 4.50E-03 4.40E-03 4.20E-03 4.40E-03 4.00E-03 4.00E-03 4.00E-03 1845 4.40E-03 4.50E-03 4.30E-03 4.40E-03 4.20E-03 4.10E-03 4.20E-03 1846 4.60E-03 4.60E-03 4.70E-03 4.50E-03 4.40E-03 4.30E-03 4.50E-03 1847 4.40E-03 4.60E-03 4.20E-03 4.40E-03 4.30E-03 4.30E-03 4.30E-03 1848 4.40E-03 4.60E-03 4.40E-03 4.40E-03 4.40E-03 4.40E-03 4.30E-03 1849 4.50E-03 4.60E-03 4.60E-03 4.50E-03 4.30E-03 4.30E-03 4.40E-03 1850 4.50E-03 4.60E-03 4.70E-03 4.40E-03 4.40E-03 4.40E-03 4.50E-03 1851 4.40E-03 4.60E-03 4.40E-03 4.40E-03 4.40E-03 4.50E-03 4.40E-03 1852 4.50E-03 4.60E-03 4.50E-03 4.40E-03 4.50E-03 4.60E-03 4.50E-03 Biased Statistics Average Biased 4.50E-03 4.52E-03 4.32E-03 4.44E-03 4.18E-03 4.14E-03 4.12E-03 Std Dev Biased 1.22E-04 1.30E-04 1.10E-04 5.48E-05 1.10E-04 1.14E-04 8.37E-05 Ps90%/90% (+KTL) Biased 4.84E-03 4.88E-03 4.62E-03 4.59E-03 4.48E-03 4.45E-03 4.35E-03 Ps90%/90% (-KTL) Biased 4.16E-03 4.16E-03 4.02E-03 4.29E-03 3.88E-03 3.83E-03 3.89E-03 Un-Biased Statistics Average Un-Biased 4.48E-03 4.60E-03 4.52E-03 4.44E-03 4.36E-03 4.34E-03 4.40E-03 Std Dev Un-Biased 8.37E-05 0.00E+00 2.17E-04 5.48E-05 5.48E-05 5.48E-05 1.00E-04 Ps90%/90% (+KTL) Un-Biased 4.71E-03 4.60E-03 5.11E-03 4.59E-03 4.51E-03 4.49E-03 4.67E-03 Ps90%/90% (-KTL) Un-Biased 4.25E-03 4.60E-03 3.93E-03 4.29E-03 4.21E-03 4.19E-03 4.13E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 168 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 1 IL=1mA @ +5V (V) 1.20E+00 1.00E+00 8.00E-01 6.00E-01 4.00E-01 2.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.81. Plot of Output Voltage Low 1 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 169 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.81. Raw data for Output Voltage Low 1 IL=1mA @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 1 IL=1mA @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 2.42E-01 2.40E-01 2.39E-01 2.41E-01 2.45E-01 2.45E-01 2.49E-01 1842 2.45E-01 2.43E-01 2.43E-01 2.44E-01 2.47E-01 2.47E-01 2.51E-01 1843 2.37E-01 2.36E-01 2.36E-01 2.39E-01 2.43E-01 2.43E-01 2.47E-01 1844 2.43E-01 2.42E-01 2.40E-01 2.43E-01 2.46E-01 2.46E-01 2.50E-01 1845 2.42E-01 2.42E-01 2.41E-01 2.42E-01 2.46E-01 2.46E-01 2.49E-01 1846 2.40E-01 2.39E-01 2.38E-01 2.39E-01 2.42E-01 2.40E-01 2.43E-01 1847 2.37E-01 2.33E-01 2.33E-01 2.34E-01 2.36E-01 2.36E-01 2.38E-01 1848 2.45E-01 2.41E-01 2.40E-01 2.41E-01 2.43E-01 2.43E-01 2.45E-01 1849 2.41E-01 2.39E-01 2.38E-01 2.39E-01 2.42E-01 2.41E-01 2.44E-01 1850 2.43E-01 2.39E-01 2.38E-01 2.39E-01 2.41E-01 2.41E-01 2.43E-01 1851 2.41E-01 2.41E-01 2.40E-01 2.40E-01 2.40E-01 2.40E-01 2.41E-01 1852 2.38E-01 2.38E-01 2.37E-01 2.37E-01 2.36E-01 2.37E-01 2.37E-01 Biased Statistics Average Biased 2.42E-01 2.41E-01 2.40E-01 2.42E-01 2.45E-01 2.45E-01 2.49E-01 Std Dev Biased 2.95E-03 2.79E-03 2.59E-03 1.92E-03 1.52E-03 1.52E-03 1.48E-03 Ps90%/90% (+KTL) Biased 2.50E-01 2.48E-01 2.47E-01 2.47E-01 2.50E-01 2.50E-01 2.53E-01 Ps90%/90% (-KTL) Biased 2.34E-01 2.33E-01 2.33E-01 2.37E-01 2.41E-01 2.41E-01 2.45E-01 Un-Biased Statistics Average Un-Biased 2.41E-01 2.38E-01 2.37E-01 2.38E-01 2.41E-01 2.40E-01 2.43E-01 Std Dev Un-Biased 3.03E-03 3.03E-03 2.61E-03 2.61E-03 2.77E-03 2.59E-03 2.70E-03 Ps90%/90% (+KTL) Un-Biased 2.50E-01 2.47E-01 2.45E-01 2.46E-01 2.48E-01 2.47E-01 2.50E-01 Ps90%/90% (-KTL) Un-Biased 2.33E-01 2.30E-01 2.30E-01 2.31E-01 2.33E-01 2.33E-01 2.35E-01 Specification MAX 3.50E-01 6.00E-01 8.00E-01 8.00E-01 1.00E+00 1.00E+00 1.00E+00 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 170 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 2 IL=1mA @ +5V (V) 1.20E+00 1.00E+00 8.00E-01 6.00E-01 4.00E-01 2.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.82. Plot of Output Voltage Low 2 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 171 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.82. Raw data for Output Voltage Low 2 IL=1mA @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 2 IL=1mA @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 2.30E-01 2.28E-01 2.29E-01 2.31E-01 2.35E-01 2.35E-01 2.38E-01 1842 2.38E-01 2.37E-01 2.35E-01 2.37E-01 2.40E-01 2.40E-01 2.45E-01 1843 2.38E-01 2.36E-01 2.35E-01 2.37E-01 2.41E-01 2.41E-01 2.44E-01 1844 2.37E-01 2.34E-01 2.33E-01 2.36E-01 2.40E-01 2.40E-01 2.42E-01 1845 2.40E-01 2.38E-01 2.36E-01 2.38E-01 2.41E-01 2.41E-01 2.45E-01 1846 2.34E-01 2.31E-01 2.30E-01 2.31E-01 2.34E-01 2.33E-01 2.35E-01 1847 2.37E-01 2.34E-01 2.34E-01 2.35E-01 2.36E-01 2.36E-01 2.38E-01 1848 2.39E-01 2.35E-01 2.35E-01 2.36E-01 2.37E-01 2.37E-01 2.39E-01 1849 2.37E-01 2.34E-01 2.34E-01 2.35E-01 2.37E-01 2.36E-01 2.38E-01 1850 2.40E-01 2.37E-01 2.36E-01 2.37E-01 2.39E-01 2.39E-01 2.40E-01 1851 2.36E-01 2.36E-01 2.35E-01 2.36E-01 2.35E-01 2.35E-01 2.35E-01 1852 2.34E-01 2.34E-01 2.33E-01 2.33E-01 2.32E-01 2.33E-01 2.33E-01 Biased Statistics Average Biased 2.37E-01 2.35E-01 2.34E-01 2.36E-01 2.39E-01 2.39E-01 2.43E-01 Std Dev Biased 3.85E-03 3.97E-03 2.79E-03 2.77E-03 2.51E-03 2.51E-03 2.95E-03 Ps90%/90% (+KTL) Biased 2.47E-01 2.45E-01 2.41E-01 2.43E-01 2.46E-01 2.46E-01 2.51E-01 Ps90%/90% (-KTL) Biased 2.26E-01 2.24E-01 2.26E-01 2.28E-01 2.33E-01 2.33E-01 2.35E-01 Un-Biased Statistics Average Un-Biased 2.37E-01 2.34E-01 2.34E-01 2.35E-01 2.37E-01 2.36E-01 2.38E-01 Std Dev Un-Biased 2.30E-03 2.17E-03 2.28E-03 2.28E-03 1.82E-03 2.17E-03 1.87E-03 Ps90%/90% (+KTL) Un-Biased 2.44E-01 2.40E-01 2.40E-01 2.41E-01 2.42E-01 2.42E-01 2.43E-01 Ps90%/90% (-KTL) Un-Biased 2.31E-01 2.28E-01 2.28E-01 2.29E-01 2.32E-01 2.30E-01 2.33E-01 Specification MAX 3.50E-01 6.00E-01 8.00E-01 8.00E-01 1.00E+00 1.00E+00 1.00E+00 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 172 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 3 IL=1mA @ +5V (V) 1.20E+00 1.00E+00 8.00E-01 6.00E-01 4.00E-01 2.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.83. Plot of Output Voltage Low 3 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 173 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.83. Raw data for Output Voltage Low 3 IL=1mA @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 3 IL=1mA @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 2.35E-01 2.33E-01 2.33E-01 2.36E-01 2.40E-01 2.41E-01 2.45E-01 1842 2.43E-01 2.42E-01 2.40E-01 2.43E-01 2.46E-01 2.46E-01 2.51E-01 1843 2.43E-01 2.41E-01 2.40E-01 2.42E-01 2.46E-01 2.46E-01 2.50E-01 1844 2.42E-01 2.39E-01 2.39E-01 2.41E-01 2.45E-01 2.45E-01 2.49E-01 1845 2.45E-01 2.42E-01 2.41E-01 2.43E-01 2.47E-01 2.47E-01 2.50E-01 1846 2.38E-01 2.35E-01 2.35E-01 2.36E-01 2.38E-01 2.38E-01 2.40E-01 1847 2.41E-01 2.38E-01 2.37E-01 2.39E-01 2.41E-01 2.40E-01 2.43E-01 1848 2.44E-01 2.40E-01 2.40E-01 2.40E-01 2.43E-01 2.43E-01 2.44E-01 1849 2.42E-01 2.39E-01 2.38E-01 2.40E-01 2.41E-01 2.41E-01 2.43E-01 1850 2.45E-01 2.42E-01 2.41E-01 2.42E-01 2.44E-01 2.44E-01 2.46E-01 1851 2.42E-01 2.41E-01 2.40E-01 2.41E-01 2.40E-01 2.40E-01 2.40E-01 1852 2.39E-01 2.39E-01 2.37E-01 2.37E-01 2.38E-01 2.38E-01 2.38E-01 Biased Statistics Average Biased 2.42E-01 2.39E-01 2.39E-01 2.41E-01 2.45E-01 2.45E-01 2.49E-01 Std Dev Biased 3.85E-03 3.78E-03 3.21E-03 2.92E-03 2.77E-03 2.35E-03 2.35E-03 Ps90%/90% (+KTL) Biased 2.52E-01 2.50E-01 2.47E-01 2.49E-01 2.52E-01 2.51E-01 2.55E-01 Ps90%/90% (-KTL) Biased 2.31E-01 2.29E-01 2.30E-01 2.33E-01 2.37E-01 2.39E-01 2.43E-01 Un-Biased Statistics Average Un-Biased 2.42E-01 2.39E-01 2.38E-01 2.39E-01 2.41E-01 2.41E-01 2.43E-01 Std Dev Un-Biased 2.74E-03 2.59E-03 2.39E-03 2.19E-03 2.30E-03 2.39E-03 2.17E-03 Ps90%/90% (+KTL) Un-Biased 2.50E-01 2.46E-01 2.45E-01 2.45E-01 2.48E-01 2.48E-01 2.49E-01 Ps90%/90% (-KTL) Un-Biased 2.34E-01 2.32E-01 2.32E-01 2.33E-01 2.35E-01 2.35E-01 2.37E-01 Specification MAX 3.50E-01 6.00E-01 8.00E-01 8.00E-01 1.00E+00 1.00E+00 1.00E+00 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 174 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased Output Voltage Low 4 IL=1mA @ +5V (V) 1.20E+00 1.00E+00 8.00E-01 6.00E-01 4.00E-01 2.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) 24-hr 60 Anneal 168-hr 70 Anneal Figure 5.84. Plot of Output Voltage Low 4 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 175 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.84. Raw data for Output Voltage Low 4 IL=1mA @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 hr 168 hr Total Dose (krad(Si)) Anneal Anneal Output Voltage Low 4 IL=1mA @ +5V (V) Device 0 10 20 30 50 60 70 Date 10/20/2011 12/12/2011 12/23/2011 1/3/2011 1/27/2011 1/28/2011 2/4/2011 1841 2.36E-01 2.35E-01 2.34E-01 2.35E-01 2.39E-01 2.39E-01 2.42E-01 1842 2.41E-01 2.39E-01 2.38E-01 2.40E-01 2.42E-01 2.42E-01 2.46E-01 1843 2.32E-01 2.32E-01 2.32E-01 2.34E-01 2.38E-01 2.38E-01 2.41E-01 1844 2.38E-01 2.36E-01 2.35E-01 2.37E-01 2.40E-01 2.40E-01 2.43E-01 1845 2.37E-01 2.36E-01 2.35E-01 2.37E-01 2.40E-01 2.40E-01 2.43E-01 1846 2.35E-01 2.34E-01 2.33E-01 2.34E-01 2.36E-01 2.35E-01 2.37E-01 1847 2.33E-01 2.30E-01 2.30E-01 2.31E-01 2.32E-01 2.32E-01 2.34E-01 1848 2.40E-01 2.37E-01 2.36E-01 2.37E-01 2.39E-01 2.39E-01 2.41E-01 1849 2.36E-01 2.34E-01 2.33E-01 2.34E-01 2.36E-01 2.36E-01 2.37E-01 1850 2.37E-01 2.34E-01 2.33E-01 2.34E-01 2.36E-01 2.36E-01 2.38E-01 1851 2.37E-01 2.36E-01 2.35E-01 2.35E-01 2.35E-01 2.35E-01 2.36E-01 1852 2.33E-01 2.33E-01 2.32E-01 2.32E-01 2.32E-01 2.32E-01 2.33E-01 Biased Statistics Average Biased 2.37E-01 2.36E-01 2.35E-01 2.37E-01 2.40E-01 2.40E-01 2.43E-01 Std Dev Biased 3.27E-03 2.51E-03 2.17E-03 2.30E-03 1.48E-03 1.48E-03 1.87E-03 Ps90%/90% (+KTL) Biased 2.46E-01 2.42E-01 2.41E-01 2.43E-01 2.44E-01 2.44E-01 2.48E-01 Ps90%/90% (-KTL) Biased 2.28E-01 2.29E-01 2.29E-01 2.30E-01 2.36E-01 2.36E-01 2.38E-01 Un-Biased Statistics Average Un-Biased 2.36E-01 2.34E-01 2.33E-01 2.34E-01 2.36E-01 2.36E-01 2.37E-01 Std Dev Un-Biased 2.59E-03 2.49E-03 2.12E-03 2.12E-03 2.49E-03 2.51E-03 2.51E-03 Ps90%/90% (+KTL) Un-Biased 2.43E-01 2.41E-01 2.39E-01 2.40E-01 2.43E-01 2.42E-01 2.44E-01 Ps90%/90% (-KTL) Un-Biased 2.29E-01 2.27E-01 2.27E-01 2.28E-01 2.29E-01 2.29E-01 2.31E-01 Specification MAX 3.50E-01 6.00E-01 8.00E-01 8.00E-01 1.00E+00 1.00E+00 1.00E+00 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 176 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 6.0. Summary / Conclusions The low dose rate testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The low dose rate source is a GB-150 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead. During the irradiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from approximately 1mrad(Si)/s to a maximum of approximately 50rad(Si)/s, determined by the distance from the source. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the low dose rate test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. Based on this criterion the RH1014MW Quad Precision Operational Amplifier (from the lot date code identified on the first page of this test report) PASSED the enhanced low dose rate sensitivity test to the maximum tested dose level of 50krad(Si) with all parameters remaining within their datasheet specifications. Further, the data in this report can be analyzed along with the high dose rate report titled "Total Ionizing Dose (TID) Radiation Testing of the RH1014MW Quad Precision Operational Amplifier for Linear Technology" to demonstrate that these parts do not exhibit ELDRS as defined in the current test method. An ISO 9001:2008 and DSCC Certified Company 177 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix A: Photograph of a Sample Unit-Under-Test to Show Part Traceability An ISO 9001:2008 and DSCC Certified Company 178 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix B: Radiation Bias Connections and Absolute Maximum Ratings ELDRS Radiation Biased Conditions: Extracted from Linear Technology RH1014M datasheet. Pin Function Connection / Bias 1 OUT A To Pin 2 Via 10kΩ Resistor 2 -IN A To Pin 1 Via 10kΩ Resistor 3 +IN A 8V Via 10kΩ Resistor 4 V+ 5 +IN B 8V Via 10kΩ Resistor 6 -IN B To Pin 7 Via 10kΩ Resistor 7 OUT B To Pin 6 Via 10kΩ Resistor 8 OUT C To Pin 9 Via 10kΩ Resistor 9 -IN C To Pin 8 Via 10kΩ Resistor 10 +IN C 8V Via 10kΩ Resistor 11 V- 12 +IN D 8V Via 10kΩ Resistor 13 -IN D To Pin 14 Via 10kΩ Resistor 14 OUT D To Pin 13 Via 10kΩ Resistor +15V Decoupled to GND W/ 0.1µF -15V Decoupled to GND W/ 0.1µF An ISO 9001:2008 and DSCC Certified Company 179 ELDRS Report 11-573 R1.0 ELDRS Radiation Unbiased Conditions: Pin Function Connection / Bias OUT A GND 1 -IN A 2 GND 3 +IN A GND 4 V+ GND 5 +IN B GND 6 -IN B GND 7 OUT B GND 8 OUT C GND 9 -IN C GND 10 +IN C GND 11 V- GND 12 +IN D GND 13 -IN D GND 14 OUT D GND An ISO 9001:2008 and DSCC Certified Company 180 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Figure B.1. Irradiation bias circuit for the units to be irradiated under electrical bias. This figure was extracted from Linear Technology RH1014M Quad Precision Operational Amplifier Datasheet. Figure B.2. Package drawing (for reference only). This figure was extracted from Linear Technology RH1014M Quad Precision Operational Amplifier Datasheet. An ISO 9001:2008 and DSCC Certified Company 181 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix C: Electrical Test Parameters and Conditions The expected ranges of values as well as the measurement conditions are taken from Linear Technology RH1014M datasheet. All electrical tests for this device are performed on one of Aeroflex RAD's LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that provides parameter measurements for a variety of digital, analog and mixed signal products including voltage regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System achieves accuracy and sensitivity through the use of software self-calibration and an internal relay matrix with separate family boards and custom personality adapter boards. The tester uses this relay matrix to connect the required test circuits, select the appropriate voltage / current sources and establish the needed measurement loops for all the tests performed. The measured parameters and test conditions are shown in Table C.1. A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020 for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90 KTL statistics were applied to the measured standard deviation to generate the final measurement range. This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020 mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the measurement resolution is limited by the internal DACs, which results in a measured standard deviation of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC. Note that the testing and statistics used in this document are based on an “analysis of variables” technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p. 91 for a discussion of statistical treatments). Not all measured parameters are well suited to this approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify these parameters using an “attributes” approach. An ISO 9001:2008 and DSCC Certified Company 182 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.1. Measured parameters and test conditions for the RH1014MW Quad Precision Operational Amplifier. Parameter Test Conditions Positive Supply Current (ICC+) VS=±15V Negative Supply Current (IEE-) VS=±15V Input Offset Voltage (VOS1-VOS4) VS=±15V Input Offset Current (IOS1-IOS4) VS=±15V + Input Bias Current (IB+1-IB+4) VS=±15V - Input Bias Current (IB-1-IB-4) VS=±15V Common Mode Rejection Ratio (CMRR1-CMRR4) VCM = 13.5V, –15V Power Supply Rejection Ratio (PSRR1-PSRR4) VS = ±10V to ±18V Large Signal Voltage Gain (AVOL9-AVOL12) VS=±15V, VO = ±10V, RL = 10kΩ Positive Output Voltage Swing (VOUT+1-VOUT+4) VS=±15V, RL= 10kΩ Negative Output Voltage Swing (VOUT-1-VOUT-4) VS=±15V, RL= 10kΩ Positive Slew Rate (SlewRate+1 – SlewRate+4) VS=±15V, RL= 10kΩ Negative Slew Rate (SlewRate-1 – SlewRate-4) VS=±15V, RL= 10kΩ Positive Supply Current (ICC+2) VS=+5V Negative Supply Current (IEE-2) VS=+5V Input Offset Voltage (VOS5-VOS8) VS=+5V Input Offset Current (IOS5-IOS8) VS=+5V + Input Bias Current (IB+5-IB+8) VS=+5V - Input Bias Current (IB-5-IB-8) VS=+5V Positive Output Voltage Swing (VOUT+5-VOUT+8) VS=+5V, No Load Positive Output Voltage Swing (VOUT+9-VOUT+12) VS=+5V, RL= 600Ω Output Voltage Low (VOUT-5-VOUT-8) VS=+5V, No Load Output Voltage Low (VOUT-9-VOUT-12) VS=+5V, RL= 600Ω Output Voltage Low (VOUT-13-VOUT-16) VS=+5V, ISINK= 1mA An ISO 9001:2008 and DSCC Certified Company 183 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH1014MW Quad Precision Operational Amplifier. Parameter Pre-Irradiation Specification MIN Positive Supply Current (ICC+) MAX Measurement Precision/Resolution 2.20E-03 A ±5.26E-06 A Negative Supply Current (IEE-) -2.20E-03 A ±5.55E-06 A Input Offset Voltage (VOS1-VOS4) -3.00E-04 V 3.00E-04 V ±3.40E-06 V Input Offset Current (IOS1-IOS4) -1.00E-08 A +1.00E-08 A ±3.04E-11 A + Input Bias Current (IB+1-IB+4) -3.00E-08 A 3.00E-08 A ±6.02E-11 A - Input Bias Current (IB-1-IB-4) -3.00E-08 A 3.00E-08 A ±6.48E-11 A Common Mode Rejection Ratio (CMRR1-CMRR4) 97 dB ±4.79E-01 dB Power Supply Rejection Ratio (PSRR1-PSRR4) 100 dB ±3.23E+00 dB 1.20E+03 V/mV ±1.72E+04 V/mV 12.5 V ±1.90E-03 V Large Signal Voltage Gain (AVOL9-AVOL12) Positive Output Voltage Swing (VOUT+1-VOUT+4) Negative Output Voltage Swing (VOUT-1-VOUT-4) -12.5 V Positive Slew Rate (SlewRate+1-SlewRate+4) 0.2 V/µs Negative Slew Rate (SlewRate-1-SlewRate-4) Positive Supply Current (ICC+2) ±8.71E-04 V ±1.26E-02 V/µs -0.2 V/µs ±2.34E-02 V/µs 2.00E-03 A ±3.87E-06 A Negative Supply Current (IEE-2) -2.00E-03 A ±5.08E-06 A Input Offset Voltage (VOS5-VOS8) -4.50E-04 V 4.50E-04 V ±1.00E-06 V Input Offset Current (IOS5-IOS8) -1.00E-08 A 1.00E-08 A ±3.61E-11 A + Input Bias Current (IB+5-IB+8) -5.00E-08 A 5.00E-08 A ±8.80E-11 A - Input Bias Current (IB-5-IB-8) -5.00E-08 A 5.00E-08 A ±7.13E-11 A Positive Output Voltage Swing (VOUT+5-VOUT+8) 4.0 V ±1.17E-03 V Positive Output Voltage Swing (VOUT+9-VOUT+12) 3.4 V ±1.38E-03 V Output Voltage Low (VOUT-5-VOUT-8) 2.50E-02 V ±1.70E-04 V Output Voltage Low (VOUT-9-VOUT-12) 1.00E-02 V ±2.27E-04 V Output Voltage Low (VOUT-13-VOUT-16) 0.35 V ±1.09E-03 V An ISO 9001:2008 and DSCC Certified Company 184 ELDRS Report 11-573 R1.0 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix D: List of Figures Used in the Results Section (Section 5) 5.1. 5.2. 5.3. 5.4. 5.5. 5.6. 5.7. 5.8. 5.9. 5.10. 5.11. 5.12. 5.13. 5.14. 5.15. 5.16. 5.17. 5.18. 5.19. 5.20. 5.21. 5.22. 5.23. 5.24. 5.25. 5.26. 5.27. 5.28. 5.29. 5.30. 5.31. 5.32. 5.33. 5.34. 5.35. 5.36. 5.37. 5.38. 5.39. 5.40. 5.41. Positive Supply Current @ +/-15V (A) Negative Supply Current @ +/-15V (A) Offset Voltage 1 @ +/-15V (V) Offset Voltage 2 @ +/-15V (V) Offset Voltage 3 @ +/-15V (V) Offset Voltage 4 @ +/-15V (V) Offset Current 1 @ +/-15V (A) Offset Current 2 @ +/-15V (A) Offset Current 3 @ +/-15V (A) Offset Current 4 @ +/-15V (A) Positive Bias Current 1 @ +/-15V (A) Positive Bias Current 2 @ +/-15V (A) Positive Bias Current 3 @ +/-15V (A) Positive Bias Current 4 @ +/-15V (A) Negative Bias Current 1 @ +/-15V (A) Negative Bias Current 2 @ +/-15V (A) Negative Bias Current 3 @ +/-15V (A) Negative Bias Current 4 @ +/-15V (A) Common Mode Rejection Ratio 1 (dB) Common Mode Rejection Ratio 2 (dB) Common Mode Rejection Ratio 3 (dB) Common Mode Rejection Ratio 4 (dB) Power Supply Rejection Ratio 1 (dB) Power Supply Rejection Ratio 2 (dB) Power Supply Rejection Ratio 3 (dB) Power Supply Rejection Ratio 4 (dB) Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) Positive Output Voltage 1 @ +/-15V (V) Positive Output Voltage 2 @ +/-15V (V) Positive Output Voltage 3 @ +/-15V (V) Positive Output Voltage 4 @ +/-15V (V) Negative Output Voltage 1 @ +/-15V (V) Negative Output Voltage 2 @ +/-15V (V) Negative Output Voltage 3 @ +/-15V (V) Negative Output Voltage 4 @ +/-15V (V) Positive Slew Rate 1 @ +/-15V (V/us) Positive Slew Rate 2 @ +/-15V (V/us) Positive Slew Rate 3 @ +/-15V (V/us) An ISO 9001:2008 and DSCC Certified Company 185 ELDRS Report 11-573 R1.0 5.42. 5.43. 5.44. 5.45. 5.46. 5.47. 5.48. 5.49. 5.50. 5.51. 5.52. 5.53. 5.54. 5.55. 5.56. 5.57. 5.58. 5.59. 5.60. 5.61. 5.62. 5.63. 5.64. 5.65. 5.66. 5.67. 5.68. 5.69. 5.70. 5.71. 5.72. 5.73. 5.74. 5.75. 5.76. 5.77. 5.78. 5.79. 5.80. 5.81. 5.82. 5.83. 5.84. Positive Slew Rate 4 @ +/-15V (V/us) Negative Slew Rate 1 @ +/-15V (V/us) Negative Slew Rate 2 @ +/-15V (V/us) Negative Slew Rate 3 @ +/-15V (V/us) Negative Slew Rate 4 @ +/-15V (V/us) Positive Supply Current @ +5V (A) Negative Supply Current @ +5V (A) Offset Voltage 1 @ +5V (V) Offset Voltage 2 @ +5V (V) Offset Voltage 3 @ +5V (V) Offset Voltage 4 @ +5V (V) Offset Current 1 @ +5V (A) Offset Current 2 @ +5V (A) Offset Current 3 @ +5V (A) Offset Current 4 @ +5V (A) Positive Bias Current 1 @ +5V (A) Positive Bias Current 2 @ +5V (A) Positive Bias Current 3 @ +5V (A) Positive Bias Current 4 @ +5V (A) Negative Bias Current 1 @ +5V (A) Negative Bias Current 2 @ +5V (A) Negative Bias Current 3 @ +5V (A) Negative Bias Current 4 @ +5V (A) Positive Output Voltage 1 RL=open @ +5V (V) Positive Output Voltage 2 RL=open @ +5V (V) Positive Output Voltage 3 RL=open @ +5V (V) Positive Output Voltage 4 RL=open @ +5V (V) Positive Output Voltage 1 RL=600 @ +5V (V) Positive Output Voltage 2 RL=600 @ +5V (V) Positive Output Voltage 3 RL=600 @ +5V (V) Positive Output Voltage 4 RL=600 @ +5V (V) Output Voltage Low 1 RL=open @ +5V (V) Output Voltage Low 2 RL=open @ +5V (V) Output Voltage Low 3 RL=open @ +5V (V) Output Voltage Low 4 RL=open @ +5V (V) Output Voltage Low 1 RL=600 @ +5V (V) Output Voltage Low 2 RL=600 @ +5V (V) Output Voltage Low 4 RL=600 @ +5V (V) Output Voltage Low 3 RL=600 @ +5V (V) Output Voltage Low 1 IL=1mA @ +5V (V) Output Voltage Low 2 IL=1mA @ +5V (V) Output Voltage Low 3 IL=1mA @ +5V (V) Output Voltage Low 4 IL=1mA @ +5V (V) An ISO 9001:2008 and DSCC Certified Company 186 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800