RLAT_200K_Report_RH1014MJ_Fab_Lot_W10905043.1_W6.pdf

TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Radiation Lot Acceptance Testing (RLAT) of the RH1014MJ Quad Precision
Operational Amplifier for Linear Technology
Customer: Linear Technology, PO# 61277L
RAD Job Number: 11-679
Part Type Tested: RH1014MJ Quad Precision Operational Amplifier, RH1014M Datasheet
Traceability Information: Fab Lot Number: W10905043.1, Wafer Number: 6, Assembly Lot Number:
636350.1, Date Code: 1131A. See photograph of unit under test in Appendix A.
Quantity of Units: 12 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 2
units for control. Serial numbers 350, 351, 352, 353 and 354 were biased during irradiation, serial
numbers 355, 356, 357, 358 and 359 were unbiased during irradiation and serial numbers 360 and 361
were used as control. See Appendix B for the radiation bias connection table.
Radiation and Electrical Test Increments: 50 to 300rad(Si)/s ionizing radiation with electrical test
increments: pre-irradiation, 20krad(Si), 50krad(Si), 100krad(Si) and 200krad(Si).
Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD
Overtest and Post-Irradiation Anneal: No overtest. No anneal.
Radiation Test Standard: MIL-STD-750E TM1019 and/or MIL-STD-883H TM1019 Condition A.
Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS04, Calibration Date:
4/28/2011, Calibration Due: 4/28/2012. BGSS-970312 RH1014 DUT Board. Test Program:
RH1014LT.SRC
Facility and Radiation Source: Aeroflex RAD's Longmire Laboratories, Colorado Springs, CO.
Gamma rays provided by JLSA 81-24 Co60 source. Dosimetry performed by Air Ionization Chamber
(AIC) traceable to NIST. Aeroflex RAD's dosimetry has been audited by DSCC and Aeroflex RAD has
been awarded Laboratory Suitability for MIL-STD-750 and MIL-STD-883 TM 1019.
Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and
MIL-STD-750.
RLAT Result: PASSED the total ionizing dose test to the maximum tested dose
level of 200krad(Si) with all parameters remaining within their datasheet
specifications.
An ISO 9001:2008 and DSCC Certified Company
1
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
1.0. Overview and Background
It is well known that total dose ionizing radiation can cause parametric degradation and ultimately
functional failure in electronic devices. The damage occurs via electron-hole pair production, transport
and trapping in the dielectric and interface regions. In discrete devices the bulk of the damage is
frequently manifested as a reduction in the gain and/or breakdown voltage of the device. The damage
will usually anneal with time following the end of the radiation exposure. Due to this annealing, and to
ensure a worst-case test condition MIL-STD-883 TM1019.8 calls out a dose rate of 50 to 300rad(Si)/s as
Condition A and further specifies that the time from the end of an incremental radiation exposure and
electrical testing shall be 1-hour or less and the total time from the end of one incremental irradiation to
the beginning of the next incremental radiation step should be 2-hours or less. The work described in
this report was performed to meet MIL-STD-883 TM1019.8 Condition A.
2.0. Radiation Test Apparatus
The total ionizing dose testing described in this final report was performed using the facilities at
Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose
(TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are
held in the base of the irradiator heavily shielded by lead. During the radiation exposures the rod is
raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this
irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s,
determined by the distance from the source. For high-dose rate experiments the bias boards are placed in
a radial fashion equidistant from the raised Co-60 rods with the distance adjusted to provide the required
dose rate. The irradiator calibration is maintained by Aeroflex RAD Longmire Laboratories using air
ionization chamber (AIC) equipment calibrated with traceability to the National Institute of Standards
and Technology (NIST). Figure 2.1 shows a photograph of the JLSA 81-24 Co-60 irradiator at
Aeroflex RAD's Longmire Laboratory facility.
Aeroflex RAD is currently certified by the Defense Supply Center Columbus (DSCC) for Laboratory
Suitability under MIL STD 750 and MIL-STD-883. Additional details regarding Aeroflex RAD
dosimetry for TM1019 Condition A testing are available in Aeroflex RAD's report to DSCC entitled:
"Dose Rate Mapping of the J.L. Shepherd and Associates Model 81 Irradiator Installed by Radiation
Assured Devices".
An ISO 9001:2008 and DSCC Certified Company
2
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Figure 2.1. Aeroflex RAD's high dose rate Co-60 irradiator. The dose rate is obtained by positioning the deviceunder-test at a fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately
120rad(Si)/s close to the rods down to 1rad(Si)/s at a distance of approximately 2-feet.
An ISO 9001:2008 and DSCC Certified Company
3
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
3.0. Radiation Test Conditions
The RH1014MJ Quad Precision Operational Amplifier described in this final report were irradiated
using a split 15 supply and with all pins tied to ground, that is biased and unbiased. See the TID Bias
Table in Appendix B for the full bias circuits. In our opinion, this bias circuit satisfies the requirements
of MIL-STD-883H TM1019.8 Section 3.9.3 Bias and Loading Conditions which states "The bias
applied to the test devices shall be selected to produce the greatest radiation induced damage or the
worst-case damage for the intended application, if known. While maximum voltage is often worst case
some bipolar linear device parameters (e.g. input bias current or maximum output load current) exhibit
more degradation with 0 V bias."
The devices were irradiated to a maximum total ionizing dose level of 200krad(Si) with incremental
readings at 20krad(Si), 50krad(Si) and 100krad(Si). Electrical testing occurred within one hour
following the end of each irradiation segment. For intermediate irradiations, the parts were tested and
returned to total dose exposure within two hours from the end of the previous radiation increment.
The TID bias board was positioned in the Co-60 cell to provide the required minimum of 50rad(Si)/s
and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019.8 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test
specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm
Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and
for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1)
initially, (2) when the source is changed, or (3) when the orientation or configuration of the source,
container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g.,
a TLD) in the device-irradiation container at the approximate test-device position. If it can be
demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors
due to dose enhancement, the Pb/Al container may be omitted."
The final dose rate within the high dose rate lead-aluminum enclosure was determined using calibration
calculations based on air ionization chamber (AIC) dosimetry performed just prior to beginning the total
dose irradiations. The final dose rate for this work was 50.6 with a precision of ±5%.
An ISO 9001:2008 and DSCC Certified Company
4
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
4.0. Tested Parameters
During the total ionizing dose characterization testing the following electrical parameters were measured
pre- and post-irradiation:
1. Positive Supply Current @ +/-15V (A)
2. Negative Supply Current @ +/-15V (A)
3. Offset Voltage 1 @ +/-15V (V)
4. Offset Voltage 2 @ +/-15V (V)
5. Offset Voltage 3 @ +/-15V (V)
6. Offset Voltage 4 @ +/-15V (V)
7. Offset Current 1 @ +/-15V (A)
8. Offset Current 2 @ +/-15V (A)
9. Offset Current 3 @ +/-15V (A)
10. Offset Current 4 @ +/-15V (A)
11. Positive Bias Current 1 @ +/-15V (A)
12. Positive Bias Current 2 @ +/-15V (A)
13. Positive Bias Current 3 @ +/-15V (A)
14. Positive Bias Current 4 @ +/-15V (A)
15. Negative Bias Current 1 @ +/-15V (A)
16. Negative Bias Current 2 @ +/-15V (A)
17. Negative Bias Current 3 @ +/-15V (A)
18. Negative Bias Current 4 @ +/-15V (A)
19. Common Mode Rejection Ratio 1 (dB)
20. Common Mode Rejection Ratio 2 (dB)
21. Common Mode Rejection Ratio 3 (dB)
22. Common Mode Rejection Ratio 4 (dB)
23. Power Supply Rejection Ratio 1 (dB)
24. Power Supply Rejection Ratio 2 (dB)
25. Power Supply Rejection Ratio 3 (dB)
26. Power Supply Rejection Ratio 4 (dB)
27. Open Loop Gain 1 RL=10k VO=+/-10V (V/mV)
28. Open Loop Gain 2 RL=10k VO=+/-10V (V/mV)
29. Open Loop Gain 3 RL=10k VO=+/-10V (V/mV)
30. Open Loop Gain 4 RL=10k VO=+/-10V (V/mV)
31. Positive Output Voltage 1 @ +/-15V (V)
32. Positive Output Voltage 2 @ +/-15V (V)
33. Positive Output Voltage 3 @ +/-15V (V)
34. Positive Output Voltage 4 @ +/-15V (V)
35. Negative Output Voltage 1 @ +/-15V (V)
36. Negative Output Voltage 2 @ +/-15V (V)
37. Negative Output Voltage 3 @ +/-15V (V)
An ISO 9001:2008 and DSCC Certified Company
5
TID Report
11-679 120209 R1.0
38. Negative Output Voltage 4 @ +/-15V (V)
39. Positive Slew Rate 1 @ +/-15V (V/us)
40. Positive Slew Rate 2 @ +/-15V (V/us)
41. Positive Slew Rate 3 @ +/-15V (V/us)
42. Positive Slew Rate 4 @ +/-15V (V/us)
43. Negative Slew Rate 1 @ +/-15V (V/us)
44. Negative Slew Rate 2 @ +/-15V (V/us)
45. Negative Slew Rate 3 @ +/-15V (V/us)
46. Negative Slew Rate 4 @ +/-15V (V/us)
47. Positive Supply Current @ +5V (A)
48. Negative Supply Current @ +5V (A)
49. Offset Voltage 1 @ +5V (V)
50. Offset Voltage 2 @ +5V (V)
51. Offset Voltage 3 @ +5V (V)
52. Offset Voltage 4 @ +5V (V)
53. Offset Current 1 @ +5V (A)
54. Offset Current 2 @ +5V (A)
55. Offset Current 3 @ +5V (A)
56. Offset Current 4 @ +5V (A)
57. Positive Bias Current 1 @ +5V (A)
58. Positive Bias Current 2 @ +5V (A)
59. Positive Bias Current 3 @ +5V (A)
60. Positive Bias Current 4 @ +5V (A)
61. Negative Bias Current 1 @ +5V (A)
62. Negative Bias Current 2 @ +5V (A)
63. Negative Bias Current 3 @ +5V (A)
64. Negative Bias Current 4 @ +5V (A)
65. Positive Output Voltage 1 RL=open @ +5V (V)
66. Positive Output Voltage 2 RL=open @ +5V (V)
67. Positive Output Voltage 3 RL=open @ +5V (V)
68. Positive Output Voltage 4 RL=open @ +5V (V)
69. Positive Output Voltage 1 RL=600 @ +5V (V)
70. Positive Output Voltage 2 RL=600 @ +5V (V)
71. Positive Output Voltage 3 RL=600 @ +5V (V)
72. Positive Output Voltage 4 RL=600 @ +5V (V)
73. Output Voltage Low 1 RL=open @ +5V (V)
74. Output Voltage Low 2 RL=open @ +5V (V)
75. Output Voltage Low 3 RL=open @ +5V (V)
76. Output Voltage Low 4 RL=open @ +5V (V)
77. Output Voltage Low 1 RL=600 @ +5V (V)
78. Output Voltage Low 2 RL=600 @ +5V (V)
79. Output Voltage Low 3 RL=600 @ +5V (V)
An ISO 9001:2008 and DSCC Certified Company
6
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
80. Output Voltage Low 4 RL=600 @ +5V (V)
81. Output Voltage Low 1 IL=1mA @ +5V (V)
82. Output Voltage Low 2 IL=1mA @ +5V (V)
83. Output Voltage Low 3 IL=1mA @ +5V (V)
84. Output Voltage Low 4 IL=1mA @ +5V (V)
Appendix C details the measured parameters, test conditions, pre-irradiation specification and
measurement resolution for each of the measurements.
The parametric data was obtained as "read and record" and all the raw data plus an attributes summary
are contained in this report as well as in a separate Excel file. The attributes data contains the average,
standard deviation and the average with the KTL values applied. The KTL value used in this work is
2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The
90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535
sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the
following criteria must be met for a device to pass the total ionizing dose test: following the radiation
exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units
irradiated without electrical bias and the KTL statistics are included in this report for reference only. If
any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet
specification limits, then the lot could be logged as a failure.
An ISO 9001:2008 and DSCC Certified Company
7
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
5.0. Total Ionizing Dose Test Results
Based on this criterion the RH1014MJ Quad Precision Operational Amplifier (from the lot traceability
information provided on the first page of this test report) PASSED the total ionizing dose test to the
maximum tested dose level of 200krad(Si) with all parameters remaining within their datasheet
specifications.
Figures 5.1 through 5.84 show plots of all the measured parameters versus total ionizing dose while
Tables 5.1 - 5.84 show the corresponding raw data for each of these parameters. In the data plots the
solid diamonds are the average of the measured data points for the sample irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the units irradiated with all
pins tied to ground. The black lines (solid or dashed) are the average of the data points after application
of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or
dashed) are the average of the data points after application of the KTL statistics on the sample irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or
maximum specification value as defined in the datasheet and/or test plan.
The control units, as expected, show no significant changes to any of the parameters. Therefore we can
conclude that the electrical testing remained in control throughout the duration of the tests and the
observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section
to facilitate the location of a particular parameter.
An ISO 9001:2008 and DSCC Certified Company
8
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Positive Supply Current @ +/-15V (A)
2.50E-03
2.00E-03
1.50E-03
1.00E-03
5.00E-04
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.1. Plot of Positive Supply Current @ +/-15V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
9
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.1. Raw data for Positive Supply Current @ +/-15V (A) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Supply Current @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.50E-03
1.53E-03
1.50E-03
1.39E-03
1.18E-03
351
1.50E-03
1.53E-03
1.49E-03
1.39E-03
1.18E-03
352
1.54E-03
1.57E-03
1.53E-03
1.43E-03
1.23E-03
353
1.55E-03
1.56E-03
1.52E-03
1.41E-03
1.20E-03
354
1.52E-03
1.57E-03
1.51E-03
1.41E-03
1.20E-03
355
1.61E-03
1.65E-03
1.60E-03
1.50E-03
1.27E-03
356
1.51E-03
1.57E-03
1.52E-03
1.41E-03
1.18E-03
357
1.52E-03
1.56E-03
1.51E-03
1.40E-03
1.18E-03
358
1.51E-03
1.56E-03
1.51E-03
1.41E-03
1.19E-03
359
1.50E-03
1.55E-03
1.51E-03
1.40E-03
1.18E-03
360
1.50E-03
1.49E-03
1.49E-03
1.49E-03
1.49E-03
361
1.52E-03
1.52E-03
1.52E-03
1.52E-03
1.52E-03
Biased Statistics
Average Biased
1.52E-03
1.55E-03
1.51E-03
1.41E-03
1.20E-03
Std Dev Biased
2.26E-05
2.05E-05
1.55E-05
1.57E-05
2.01E-05
Ps90%/90% (+KTL) Biased
1.58E-03
1.61E-03
1.55E-03
1.45E-03
1.26E-03
Ps90%/90% (-KTL) Biased
1.46E-03
1.49E-03
1.47E-03
1.36E-03
1.15E-03
Un-Biased Statistics
Average Un-Biased
1.53E-03
1.58E-03
1.53E-03
1.42E-03
1.20E-03
Std Dev Un-Biased
4.48E-05
4.22E-05
4.22E-05
4.08E-05
3.84E-05
Ps90%/90% (+KTL) Un-Biased
1.65E-03
1.69E-03
1.64E-03
1.54E-03
1.30E-03
Ps90%/90% (-KTL) Un-Biased
1.41E-03
1.46E-03
1.41E-03
1.31E-03
1.09E-03
Specification MAX
2.20E-03
2.20E-03
2.20E-03
2.20E-03
2.20E-03
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
10
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Negative Supply Current @ +/-15V (A)
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
-2.00E-03
-2.50E-03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.2. Plot of Negative Supply Current @ +/-15V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
11
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.2. Raw data for Negative Supply Current @ +/-15V (A) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Supply Current @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -1.50E-03 -1.53E-03 -1.50E-03 -1.39E-03 -1.18E-03
351 -1.50E-03 -1.53E-03 -1.49E-03 -1.39E-03 -1.18E-03
352 -1.54E-03 -1.57E-03 -1.53E-03 -1.43E-03 -1.23E-03
353 -1.55E-03 -1.56E-03 -1.52E-03 -1.41E-03 -1.21E-03
354 -1.52E-03 -1.57E-03 -1.51E-03 -1.41E-03 -1.20E-03
355 -1.61E-03 -1.66E-03 -1.61E-03 -1.50E-03 -1.27E-03
356 -1.52E-03 -1.57E-03 -1.52E-03 -1.41E-03 -1.19E-03
357 -1.52E-03 -1.56E-03 -1.51E-03 -1.40E-03 -1.18E-03
358 -1.51E-03 -1.56E-03 -1.51E-03 -1.41E-03 -1.19E-03
359 -1.51E-03 -1.55E-03 -1.51E-03 -1.40E-03 -1.18E-03
360 -1.50E-03 -1.49E-03 -1.50E-03 -1.50E-03 -1.49E-03
361 -1.53E-03 -1.52E-03 -1.52E-03 -1.52E-03 -1.52E-03
Biased Statistics
Average Biased
-1.52E-03 -1.55E-03 -1.51E-03 -1.41E-03 -1.20E-03
Std Dev Biased
2.21E-05
2.00E-05
1.55E-05
1.67E-05
2.14E-05
Ps90%/90% (+KTL) Biased
-1.46E-03 -1.50E-03 -1.47E-03 -1.36E-03 -1.14E-03
Ps90%/90% (-KTL) Biased
-1.58E-03 -1.61E-03 -1.55E-03 -1.45E-03 -1.26E-03
Un-Biased Statistics
Average Un-Biased
-1.53E-03 -1.58E-03 -1.53E-03 -1.43E-03 -1.20E-03
Std Dev Un-Biased
4.46E-05
4.25E-05
4.25E-05
4.06E-05
3.88E-05
Ps90%/90% (+KTL) Un-Biased
-1.41E-03 -1.46E-03 -1.41E-03 -1.31E-03 -1.09E-03
Ps90%/90% (-KTL) Un-Biased
-1.66E-03 -1.70E-03 -1.65E-03 -1.54E-03 -1.31E-03
Specification MIN
-2.20E-03 -2.20E-03 -2.20E-03 -2.20E-03 -2.20E-03
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
12
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-03
Offset Voltage 1 @ +/-15V (V)
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.3. Plot of Offset Voltage 1 @ +/-15V (V) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
13
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.3. Raw data for Offset Voltage 1 @ +/-15V (V) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Voltage 1 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -1.97E-05 -1.65E-05
1.55E-05
6.04E-05
1.50E-04
351
6.10E-05
6.02E-05
8.17E-05
1.22E-04
1.96E-04
352 -2.58E-05 -2.60E-05 -4.17E-06
3.99E-05
1.04E-04
353 -9.11E-06 -1.84E-05
9.72E-06
3.19E-05
6.90E-05
354
4.28E-05 -3.04E-05
6.21E-05
8.94E-05
1.49E-04
355 -5.37E-06 -2.24E-06
2.07E-05
6.24E-05
1.44E-04
356 -3.81E-05 -3.19E-05 -1.33E-05
1.99E-05
9.63E-05
357 -2.11E-05 -1.62E-05 -1.80E-07
3.95E-05
1.12E-04
358
3.08E-06
1.20E-05
4.33E-05
9.70E-05
2.04E-04
359 -4.45E-05 -4.79E-05 -1.38E-05
3.95E-05
1.35E-04
360
9.11E-06
7.78E-06
8.15E-06
9.60E-06
5.49E-06
361
2.88E-05
2.77E-05
2.69E-05
2.82E-05
3.16E-05
Biased Statistics
Average Biased
9.84E-06 -6.22E-06
3.30E-05
6.88E-05
1.34E-04
Std Dev Biased
3.94E-05
3.75E-05
3.69E-05
3.73E-05
4.85E-05
Ps90%/90% (+KTL) Biased
1.18E-04
9.67E-05
1.34E-04
1.71E-04
2.67E-04
Ps90%/90% (-KTL) Biased
-9.82E-05 -1.09E-04 -6.82E-05 -3.34E-05
6.27E-07
Un-Biased Statistics
Average Un-Biased
-2.12E-05 -1.73E-05
7.33E-06
5.17E-05
1.38E-04
Std Dev Un-Biased
2.04E-05
2.36E-05
2.45E-05
2.95E-05
4.13E-05
Ps90%/90% (+KTL) Un-Biased
3.48E-05
4.76E-05
7.45E-05
1.32E-04
2.51E-04
Ps90%/90% (-KTL) Un-Biased
-7.72E-05 -8.21E-05 -5.99E-05 -2.92E-05
2.51E-05
Specification MIN
-3.00E-04 -4.50E-04 -6.00E-04 -7.50E-04 -9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-04
4.50E-04
6.00E-04
7.50E-04
9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
14
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-03
Offset Voltage 2 @ +/-15V (V)
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.4. Plot of Offset Voltage 2 @ +/-15V (V) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
15
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.4. Raw data for Offset Voltage 2 @ +/-15V (V) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Voltage 2 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -4.35E-05 -3.97E-05 -2.24E-05
1.33E-05
8.22E-05
351
1.37E-04
1.42E-04
1.65E-04
2.11E-04
2.77E-04
352
5.93E-05
5.85E-05
8.23E-05
1.14E-04
1.72E-04
353
1.04E-05
8.99E-06
2.14E-05
3.98E-05
6.24E-05
354
4.75E-05
5.83E-05
7.82E-05
1.12E-04
1.80E-04
355
8.72E-05
6.56E-05
7.76E-05
1.17E-04
1.91E-04
356
5.05E-05
5.76E-05
7.44E-05
1.11E-04
1.79E-04
357 -2.02E-05 -1.38E-05
6.34E-06
3.95E-05
1.16E-04
358 -4.57E-05 -4.70E-05 -3.97E-05 -1.96E-05
2.00E-05
359 -5.13E-06
4.28E-06
1.99E-05
5.97E-05
1.45E-04
360
3.80E-06
9.84E-06
8.15E-06
8.87E-06
7.30E-06
361 -2.83E-05 -2.47E-05 -2.45E-05 -2.55E-05 -2.92E-05
Biased Statistics
Average Biased
4.22E-05
4.57E-05
6.49E-05
9.78E-05
1.55E-04
Std Dev Biased
6.65E-05
6.76E-05
7.07E-05
7.69E-05
8.61E-05
Ps90%/90% (+KTL) Biased
2.25E-04
2.31E-04
2.59E-04
3.09E-04
3.91E-04
Ps90%/90% (-KTL) Biased
-1.40E-04 -1.40E-04 -1.29E-04 -1.13E-04 -8.14E-05
Un-Biased Statistics
Average Un-Biased
1.33E-05
1.33E-05
2.77E-05
6.14E-05
1.30E-04
Std Dev Un-Biased
5.43E-05
4.79E-05
4.93E-05
5.59E-05
6.84E-05
Ps90%/90% (+KTL) Un-Biased
1.62E-04
1.45E-04
1.63E-04
2.15E-04
3.18E-04
Ps90%/90% (-KTL) Un-Biased
-1.36E-04 -1.18E-04 -1.07E-04 -9.20E-05 -5.73E-05
Specification MIN
-3.00E-04 -4.50E-04 -6.00E-04 -7.50E-04 -9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-04
4.50E-04
6.00E-04
7.50E-04
9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
16
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-03
Offset Voltage 3 @ +/-15V (V)
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.5. Plot of Offset Voltage 3 @ +/-15V (V) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
17
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.5. Raw data for Offset Voltage 3 @ +/-15V (V) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Voltage 3 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
6.39E-05
6.91E-05
9.89E-05
1.43E-04
2.24E-04
351 -2.47E-05 -1.11E-05
1.37E-05
5.22E-05
1.28E-04
352 -2.01E-05 -1.71E-05
1.63E-06
2.99E-05
6.82E-05
353
5.12E-05
5.55E-05
6.91E-05
8.00E-05
1.06E-04
354
8.38E-05 -1.46E-05
1.11E-04
1.44E-04
1.93E-04
355
7.07E-05
7.24E-05
8.52E-05
1.29E-04
2.13E-04
356
3.66E-05
4.68E-05
7.13E-05
1.19E-04
2.15E-04
357 -4.63E-05 -3.36E-05 -1.12E-05
2.92E-05
9.94E-05
358 -7.34E-05 -7.52E-05 -5.44E-05 -2.31E-05
4.33E-05
359
2.67E-05
4.52E-05
6.10E-05
9.99E-05
1.90E-04
360
6.03E-05
5.89E-05
5.72E-05
5.68E-05
5.91E-05
361
3.35E-05
3.40E-05
3.65E-05
3.33E-05
3.19E-05
Biased Statistics
Average Biased
3.08E-05
1.64E-05
5.89E-05
8.98E-05
1.44E-04
Std Dev Biased
5.00E-05
4.22E-05
4.94E-05
5.21E-05
6.40E-05
Ps90%/90% (+KTL) Biased
1.68E-04
1.32E-04
1.94E-04
2.33E-04
3.19E-04
Ps90%/90% (-KTL) Biased
-1.06E-04 -9.95E-05 -7.66E-05 -5.30E-05 -3.15E-05
Un-Biased Statistics
Average Un-Biased
2.86E-06
1.11E-05
3.04E-05
7.08E-05
1.52E-04
Std Dev Un-Biased
6.03E-05
6.25E-05
6.03E-05
6.54E-05
7.70E-05
Ps90%/90% (+KTL) Un-Biased
1.68E-04
1.83E-04
1.96E-04
2.50E-04
3.63E-04
Ps90%/90% (-KTL) Un-Biased
-1.62E-04 -1.60E-04 -1.35E-04 -1.09E-04 -5.91E-05
Specification MIN
-3.00E-04 -4.50E-04 -6.00E-04 -7.50E-04 -9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-04
4.50E-04
6.00E-04
7.50E-04
9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
18
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-03
Offset Voltage 4 @ +/-15V (V)
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.6. Plot of Offset Voltage 4 @ +/-15V (V) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
19
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.6. Raw data for Offset Voltage 4 @ +/-15V (V) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Voltage 4 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.63E-06
1.04E-05
3.81E-05
8.46E-05
1.56E-04
351
1.67E-05
2.69E-05
4.67E-05
8.36E-05
1.61E-04
352 -3.40E-05 -2.76E-05 -1.43E-05
2.31E-05
8.70E-05
353 -7.18E-06 -1.06E-05
4.65E-06
2.47E-05
6.92E-05
354 -5.94E-05 -2.94E-05 -4.43E-05 -2.16E-05
1.93E-05
355
5.25E-06
7.18E-06
2.44E-05
5.57E-05
1.26E-04
356 -7.83E-05 -6.78E-05 -4.96E-05 -5.37E-06
8.57E-05
357
3.80E-06
1.29E-05
3.31E-05
8.07E-05
1.77E-04
358
5.91E-05
6.15E-05
8.69E-05
1.30E-04
2.27E-04
359
3.14E-05
3.24E-05
6.79E-05
1.14E-04
2.06E-04
360
6.25E-05
6.07E-05
6.07E-05
5.93E-05
5.87E-05
361
3.98E-05
4.27E-05
3.99E-05
3.99E-05
4.29E-05
Biased Statistics
Average Biased
-1.65E-05 -6.05E-06
6.17E-06
3.89E-05
9.85E-05
Std Dev Biased
3.03E-05
2.44E-05
3.75E-05
4.52E-05
6.02E-05
Ps90%/90% (+KTL) Biased
6.66E-05
6.09E-05
1.09E-04
1.63E-04
2.63E-04
Ps90%/90% (-KTL) Biased
-9.95E-05 -7.30E-05 -9.66E-05 -8.52E-05 -6.65E-05
Un-Biased Statistics
Average Un-Biased
4.26E-06
9.23E-06
3.26E-05
7.49E-05
1.64E-04
Std Dev Un-Biased
5.14E-05
4.80E-05
5.25E-05
5.33E-05
5.82E-05
Ps90%/90% (+KTL) Un-Biased
1.45E-04
1.41E-04
1.76E-04
2.21E-04
3.24E-04
Ps90%/90% (-KTL) Un-Biased
-1.37E-04 -1.22E-04 -1.11E-04 -7.13E-05
4.78E-06
Specification MIN
-3.00E-04 -4.50E-04 -6.00E-04 -7.50E-04 -9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-04
4.50E-04
6.00E-04
7.50E-04
9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
20
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Current 1 @ +/-15V (A)
3.00E-08
2.00E-08
1.00E-08
0.00E+00
-1.00E-08
-2.00E-08
-3.00E-08
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.7. Plot of Offset Current 1 @ +/-15V (A) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
21
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.7. Raw data for Offset Current 1 @ +/-15V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Current 1 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -4.00E-12 -4.30E-11 -3.30E-11 -1.61E-10 -5.90E-11
351 -2.80E-11 0.00E+00
2.20E-10
3.55E-10
6.14E-10
352 -1.00E-11 -6.50E-11 -5.40E-11
3.11E-10
4.19E-10
353
7.40E-11
1.54E-10
6.10E-11
2.19E-10
3.58E-10
354 -8.70E-11 -9.90E-11 -2.39E-10 -6.11E-10 -9.97E-10
355
6.00E-11
1.35E-10
1.72E-10
6.20E-11 -2.40E-11
356
1.60E-11
7.80E-11
5.20E-11
1.58E-10
2.03E-10
357 -2.00E-12 -6.70E-11 -1.92E-10 -2.70E-10 -4.06E-10
358 -9.90E-11 -7.10E-11 -5.50E-11 -8.00E-12 -2.82E-10
359
2.40E-11 -4.00E-11 -1.10E-11
1.15E-10
5.70E-11
360 -1.40E-10 -1.24E-10 -1.05E-10 -1.15E-10 -1.19E-10
361 -3.80E-11 -2.20E-11 -2.70E-11 -1.00E-11 -1.00E-11
Biased Statistics
Average Biased
-1.10E-11 -1.06E-11 -9.00E-12
2.26E-11
6.70E-11
Std Dev Biased
5.77E-11
9.88E-11
1.68E-10
4.08E-10
6.43E-10
Ps90%/90% (+KTL) Biased
1.47E-10
2.60E-10
4.52E-10
1.14E-09
1.83E-09
Ps90%/90% (-KTL) Biased
-1.69E-10 -2.81E-10 -4.70E-10 -1.10E-09 -1.70E-09
Un-Biased Statistics
Average Un-Biased
-2.00E-13
7.00E-12 -6.80E-12
1.14E-11 -9.04E-11
Std Dev Un-Biased
5.97E-11
9.38E-11
1.34E-10
1.69E-10
2.49E-10
Ps90%/90% (+KTL) Un-Biased
1.63E-10
2.64E-10
3.61E-10
4.75E-10
5.93E-10
Ps90%/90% (-KTL) Un-Biased
-1.64E-10 -2.50E-10 -3.75E-10 -4.52E-10 -7.74E-10
Specification MIN
-1.00E-08 -1.00E-08 -1.50E-08 -2.00E-08 -2.50E-08
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
1.00E-08
1.00E-08
1.50E-08
2.00E-08
2.50E-08
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
22
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Current 2 @ +/-15V (A)
3.00E-08
2.00E-08
1.00E-08
0.00E+00
-1.00E-08
-2.00E-08
-3.00E-08
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.8. Plot of Offset Current 2 @ +/-15V (A) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
23
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.8. Raw data for Offset Current 2 @ +/-15V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Current 2 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -1.50E-11 -1.11E-10 -8.50E-11 -3.27E-10 -1.57E-10
351 -1.05E-10 -2.70E-11
1.12E-10
6.90E-11
1.34E-10
352 -4.90E-11
5.40E-11 -2.30E-11
6.60E-11 -3.10E-11
353 -1.80E-11 -1.09E-10 -2.14E-10 -5.21E-10 -9.77E-10
354
5.50E-11
1.50E-11 -9.80E-11 -1.01E-10 -1.46E-10
355
2.20E-11 -2.00E-12
5.50E-11
7.10E-11
1.44E-10
356
4.90E-11 -1.10E-11
1.42E-10
1.73E-10
1.20E-10
357 -1.47E-10
8.00E-12 -4.80E-11
1.62E-10
5.29E-10
358
1.68E-10
2.44E-10
3.85E-10
3.38E-10
6.70E-10
359
1.04E-10
6.70E-11 -8.00E-12
4.00E-12 -1.86E-10
360 -1.25E-10 -8.80E-11 -7.90E-11 -1.09E-10 -1.04E-10
361 -1.90E-11 -9.00E-11 -8.40E-11 -6.20E-11 -9.50E-11
Biased Statistics
Average Biased
-2.64E-11 -3.56E-11 -6.16E-11 -1.63E-10 -2.35E-10
Std Dev Biased
5.81E-11
7.37E-11
1.19E-10
2.57E-10
4.31E-10
Ps90%/90% (+KTL) Biased
1.33E-10
1.67E-10
2.65E-10
5.43E-10
9.46E-10
Ps90%/90% (-KTL) Biased
-1.86E-10 -2.38E-10 -3.88E-10 -8.69E-10 -1.42E-09
Un-Biased Statistics
Average Un-Biased
3.92E-11
6.12E-11
1.05E-10
1.50E-10
2.55E-10
Std Dev Un-Biased
1.18E-10
1.07E-10
1.72E-10
1.26E-10
3.44E-10
Ps90%/90% (+KTL) Un-Biased
3.63E-10
3.54E-10
5.77E-10
4.95E-10
1.20E-09
Ps90%/90% (-KTL) Un-Biased
-2.85E-10 -2.31E-10 -3.67E-10 -1.96E-10 -6.87E-10
Specification MIN
-1.00E-08 -1.00E-08 -1.50E-08 -2.00E-08 -2.50E-08
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
1.00E-08
1.00E-08
1.50E-08
2.00E-08
2.50E-08
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
24
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Current 3 @ +/-15V (A)
3.00E-08
2.00E-08
1.00E-08
0.00E+00
-1.00E-08
-2.00E-08
-3.00E-08
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.9. Plot of Offset Current 3 @ +/-15V (A) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
25
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.9. Raw data for Offset Current 3 @ +/-15V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Current 3 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -3.50E-11 -4.70E-11
7.20E-11 -6.20E-11 -1.04E-10
351 -1.30E-11 -9.30E-11 -2.33E-10 -1.94E-10 -1.22E-10
352
6.60E-11
1.21E-10
1.07E-10 -1.09E-10 -1.03E-10
353 -7.80E-11 -1.48E-10 -1.64E-10 -4.05E-10 -1.03E-09
354 -2.40E-11
9.30E-11 -5.90E-11 -9.00E-12
8.10E-11
355
1.90E-11
3.30E-11
9.30E-11
9.10E-11 -2.40E-11
356 -2.70E-11 -2.20E-11 -4.80E-11 -3.77E-10 -4.91E-10
357 -1.80E-11 -1.06E-10 -7.50E-11
2.80E-11
3.87E-10
358 -1.00E-12
1.03E-10
8.90E-11
5.60E-11
2.65E-10
359 -1.51E-10 -1.87E-10 -2.17E-10 -2.83E-10 -6.26E-10
360 -6.60E-11 -6.70E-11 -6.90E-11 -6.20E-11 -8.60E-11
361 -1.10E-11 -2.60E-11 -3.00E-11 -3.40E-11 -4.20E-11
Biased Statistics
Average Biased
-1.68E-11 -1.48E-11 -5.54E-11 -1.56E-10 -2.55E-10
Std Dev Biased
5.24E-11
1.17E-10
1.47E-10
1.55E-10
4.39E-10
Ps90%/90% (+KTL) Biased
1.27E-10
3.07E-10
3.47E-10
2.69E-10
9.49E-10
Ps90%/90% (-KTL) Biased
-1.61E-10 -3.36E-10 -4.57E-10 -5.81E-10 -1.46E-09
Un-Biased Statistics
Average Un-Biased
-3.56E-11 -3.58E-11 -3.16E-11 -9.70E-11 -9.78E-11
Std Dev Un-Biased
6.69E-11
1.14E-10
1.29E-10
2.16E-10
4.49E-10
Ps90%/90% (+KTL) Un-Biased
1.48E-10
2.77E-10
3.22E-10
4.96E-10
1.13E-09
Ps90%/90% (-KTL) Un-Biased
-2.19E-10 -3.48E-10 -3.85E-10 -6.90E-10 -1.33E-09
Specification MIN
-1.00E-08 -1.00E-08 -1.50E-08 -2.00E-08 -2.50E-08
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
1.00E-08
1.00E-08
1.50E-08
2.00E-08
2.50E-08
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
26
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Offset Current 4 @ +/-15V (A)
3.00E-08
2.00E-08
1.00E-08
0.00E+00
-1.00E-08
-2.00E-08
-3.00E-08
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.10. Plot of Offset Current 4 @ +/-15V (A) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
27
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.10. Raw data for Offset Current 4 @ +/-15V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Current 4 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -4.40E-11 -1.25E-10
3.20E-11
1.90E-11
4.05E-10
351 -9.40E-11 -1.00E-10
3.50E-11 -2.60E-11 -2.80E-11
352 -1.50E-11 -2.30E-11
9.50E-11 -1.15E-10 -3.66E-10
353
6.00E-11
1.75E-10
1.41E-10
1.41E-10
6.63E-10
354 -8.00E-11 -2.60E-11 -3.20E-10 -4.67E-10 -6.08E-10
355
5.40E-11
1.14E-10 -2.30E-11 0.00E+00 -2.23E-10
356 -7.00E-12 -1.80E-11
1.20E-11 -1.83E-10 -1.73E-10
357 -9.50E-11 -1.38E-10 -3.44E-10 -4.81E-10 -9.05E-10
358 -2.80E-11 -1.30E-11
3.90E-11
1.20E-10
9.60E-11
359 -4.70E-11 -6.00E-11 -4.00E-11 -1.07E-10
1.06E-10
360
2.30E-11 -1.00E-11
1.70E-11
3.10E-11
3.10E-11
361
2.20E-11 -2.00E-12 -6.00E-12 -1.10E-11 -9.00E-12
Biased Statistics
Average Biased
-3.46E-11 -1.98E-11 -3.40E-12 -8.96E-11
1.32E-11
Std Dev Biased
6.13E-11
1.18E-10
1.83E-10
2.30E-10
5.26E-10
Ps90%/90% (+KTL) Biased
1.33E-10
3.03E-10
4.98E-10
5.42E-10
1.46E-09
Ps90%/90% (-KTL) Biased
-2.03E-10 -3.43E-10 -5.04E-10 -7.21E-10 -1.43E-09
Un-Biased Statistics
Average Un-Biased
-2.46E-11 -2.30E-11 -7.12E-11 -1.30E-10 -2.20E-10
Std Dev Un-Biased
5.47E-11
9.15E-11
1.56E-10
2.27E-10
4.12E-10
Ps90%/90% (+KTL) Un-Biased
1.25E-10
2.28E-10
3.55E-10
4.92E-10
9.09E-10
Ps90%/90% (-KTL) Un-Biased
-1.75E-10 -2.74E-10 -4.98E-10 -7.52E-10 -1.35E-09
Specification MIN
-1.00E-08 -1.00E-08 -1.50E-08 -2.00E-08 -2.50E-08
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
1.00E-08
1.00E-08
1.50E-08
2.00E-08
2.50E-08
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
28
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 1 @ +/-15V (A)
3.00E-07
2.00E-07
1.00E-07
0.00E+00
-1.00E-07
-2.00E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.11. Plot of Positive Bias Current 1 @ +/-15V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
29
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.11. Raw data for Positive Bias Current 1 @ +/-15V (A) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Bias Current 1 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.21E-08
1.59E-08
2.38E-08
3.69E-08
6.11E-08
351
1.21E-08
1.62E-08
2.39E-08
3.66E-08
5.98E-08
352
1.22E-08
1.60E-08
2.37E-08
3.65E-08
5.98E-08
353
1.11E-08
1.52E-08
2.30E-08
3.58E-08
5.90E-08
354
1.17E-08
1.61E-08
2.41E-08
3.77E-08
6.32E-08
355
1.19E-08
1.58E-08
2.34E-08
3.52E-08
5.73E-08
356
1.13E-08
1.52E-08
2.27E-08
3.43E-08
5.52E-08
357
1.19E-08
1.57E-08
2.30E-08
3.43E-08
5.54E-08
358
1.23E-08
1.61E-08
2.35E-08
3.46E-08
5.59E-08
359
1.17E-08
1.53E-08
2.24E-08
3.35E-08
5.40E-08
360
1.23E-08
1.23E-08
1.23E-08
1.23E-08
1.23E-08
361
1.26E-08
1.26E-08
1.26E-08
1.26E-08
1.26E-08
Biased Statistics
Average Biased
1.18E-08
1.59E-08
2.37E-08
3.67E-08
6.06E-08
Std Dev Biased
4.33E-10
4.15E-10
3.94E-10
7.03E-10
1.64E-09
Ps90%/90% (+KTL) Biased
1.30E-08
1.70E-08
2.48E-08
3.86E-08
6.51E-08
Ps90%/90% (-KTL) Biased
1.06E-08
1.48E-08
2.26E-08
3.48E-08
5.61E-08
Un-Biased Statistics
Average Un-Biased
1.18E-08
1.56E-08
2.30E-08
3.44E-08
5.56E-08
Std Dev Un-Biased
3.61E-10
3.85E-10
4.89E-10
6.13E-10
1.21E-09
Ps90%/90% (+KTL) Un-Biased
1.28E-08
1.67E-08
2.43E-08
3.61E-08
5.89E-08
Ps90%/90% (-KTL) Un-Biased
1.08E-08
1.46E-08
2.16E-08
3.27E-08
5.23E-08
Specification MIN
-3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08
7.50E-08
1.00E-07
1.75E-07
2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
30
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 2 @ +/-15V (A)
3.00E-07
2.00E-07
1.00E-07
0.00E+00
-1.00E-07
-2.00E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.12. Plot of Positive Bias Current 2 @ +/-15V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
31
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.12. Raw data for Positive Bias Current 2 @ +/-15V (A) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Bias Current 2 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.17E-08
1.52E-08
2.27E-08
3.53E-08
5.81E-08
351
1.13E-08
1.49E-08
2.19E-08
3.38E-08
5.56E-08
352
1.21E-08
1.57E-08
2.31E-08
3.53E-08
5.73E-08
353
1.07E-08
1.48E-08
2.26E-08
3.57E-08
5.93E-08
354
1.16E-08
1.58E-08
2.34E-08
3.63E-08
6.08E-08
355
1.15E-08
1.52E-08
2.22E-08
3.34E-08
5.43E-08
356
1.11E-08
1.48E-08
2.18E-08
3.30E-08
5.31E-08
357
1.13E-08
1.48E-08
2.16E-08
3.22E-08
5.18E-08
358
1.12E-08
1.47E-08
2.16E-08
3.25E-08
5.30E-08
359
1.14E-08
1.49E-08
2.17E-08
3.27E-08
5.27E-08
360
1.23E-08
1.23E-08
1.23E-08
1.23E-08
1.23E-08
361
1.08E-08
1.07E-08
1.07E-08
1.07E-08
1.07E-08
Biased Statistics
Average Biased
1.15E-08
1.53E-08
2.27E-08
3.53E-08
5.82E-08
Std Dev Biased
5.24E-10
4.72E-10
5.52E-10
9.45E-10
1.96E-09
Ps90%/90% (+KTL) Biased
1.29E-08
1.66E-08
2.43E-08
3.79E-08
6.36E-08
Ps90%/90% (-KTL) Biased
1.00E-08
1.40E-08
2.12E-08
3.27E-08
5.28E-08
Un-Biased Statistics
Average Un-Biased
1.13E-08
1.49E-08
2.18E-08
3.27E-08
5.30E-08
Std Dev Un-Biased
1.60E-10
1.82E-10
2.47E-10
4.61E-10
8.98E-10
Ps90%/90% (+KTL) Un-Biased
1.17E-08
1.54E-08
2.25E-08
3.40E-08
5.55E-08
Ps90%/90% (-KTL) Un-Biased
1.09E-08
1.44E-08
2.11E-08
3.15E-08
5.05E-08
Specification MIN
-3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08
7.50E-08
1.00E-07
1.75E-07
2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
32
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 3 @ +/-15V (A)
3.00E-07
2.00E-07
1.00E-07
0.00E+00
-1.00E-07
-2.00E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.13. Plot of Positive Bias Current 3 @ +/-15V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
33
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.13. Raw data for Positive Bias Current 3 @ +/-15V (A) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Bias Current 3 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.20E-08
1.57E-08
2.32E-08
3.60E-08
5.93E-08
351
1.23E-08
1.62E-08
2.38E-08
3.65E-08
5.97E-08
352
1.19E-08
1.55E-08
2.27E-08
3.50E-08
5.69E-08
353
1.11E-08
1.52E-08
2.33E-08
3.66E-08
6.12E-08
354
1.13E-08
1.56E-08
2.28E-08
3.55E-08
5.94E-08
355
1.18E-08
1.56E-08
2.28E-08
3.41E-08
5.54E-08
356
1.20E-08
1.61E-08
2.37E-08
3.60E-08
5.76E-08
357
1.17E-08
1.53E-08
2.22E-08
3.31E-08
5.27E-08
358
1.15E-08
1.51E-08
2.23E-08
3.35E-08
5.43E-08
359
1.25E-08
1.62E-08
2.35E-08
3.51E-08
5.66E-08
360
1.29E-08
1.28E-08
1.28E-08
1.28E-08
1.28E-08
361
1.11E-08
1.11E-08
1.11E-08
1.11E-08
1.11E-08
Biased Statistics
Average Biased
1.17E-08
1.56E-08
2.32E-08
3.59E-08
5.93E-08
Std Dev Biased
4.81E-10
3.74E-10
4.52E-10
6.74E-10
1.55E-09
Ps90%/90% (+KTL) Biased
1.31E-08
1.67E-08
2.44E-08
3.78E-08
6.35E-08
Ps90%/90% (-KTL) Biased
1.04E-08
1.46E-08
2.19E-08
3.41E-08
5.51E-08
Un-Biased Statistics
Average Un-Biased
1.19E-08
1.56E-08
2.29E-08
3.43E-08
5.53E-08
Std Dev Un-Biased
3.85E-10
4.86E-10
6.90E-10
1.19E-09
1.91E-09
Ps90%/90% (+KTL) Un-Biased
1.29E-08
1.70E-08
2.48E-08
3.76E-08
6.06E-08
Ps90%/90% (-KTL) Un-Biased
1.08E-08
1.43E-08
2.10E-08
3.11E-08
5.01E-08
Specification MIN
-3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08
7.50E-08
1.00E-07
1.75E-07
2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
34
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 4 @ +/-15V (A)
3.00E-07
2.00E-07
1.00E-07
0.00E+00
-1.00E-07
-2.00E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.14. Plot of Positive Bias Current 4 @ +/-15V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
35
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.14. Raw data for Positive Bias Current 4 @ +/-15V (A) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Bias Current 4 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.17E-08
1.53E-08
2.29E-08
3.54E-08
5.83E-08
351
1.12E-08
1.50E-08
2.21E-08
3.41E-08
5.58E-08
352
1.11E-08
1.46E-08
2.17E-08
3.39E-08
5.59E-08
353
1.08E-08
1.47E-08
2.25E-08
3.51E-08
5.79E-08
354
1.14E-08
1.47E-08
2.33E-08
3.62E-08
6.05E-08
355
1.16E-08
1.54E-08
2.29E-08
3.42E-08
5.57E-08
356
1.16E-08
1.55E-08
2.30E-08
3.49E-08
5.58E-08
357
1.22E-08
1.60E-08
2.35E-08
3.50E-08
5.61E-08
358
1.13E-08
1.49E-08
2.17E-08
3.23E-08
5.20E-08
359
1.14E-08
1.50E-08
2.18E-08
3.26E-08
5.23E-08
360
1.19E-08
1.19E-08
1.19E-08
1.19E-08
1.19E-08
361
1.16E-08
1.16E-08
1.15E-08
1.16E-08
1.15E-08
Biased Statistics
Average Biased
1.12E-08
1.49E-08
2.25E-08
3.49E-08
5.77E-08
Std Dev Biased
3.17E-10
2.89E-10
6.26E-10
9.64E-10
1.95E-09
Ps90%/90% (+KTL) Biased
1.21E-08
1.57E-08
2.42E-08
3.76E-08
6.30E-08
Ps90%/90% (-KTL) Biased
1.03E-08
1.41E-08
2.08E-08
3.23E-08
5.23E-08
Un-Biased Statistics
Average Un-Biased
1.16E-08
1.54E-08
2.26E-08
3.38E-08
5.44E-08
Std Dev Un-Biased
3.40E-10
4.49E-10
8.14E-10
1.26E-09
2.05E-09
Ps90%/90% (+KTL) Un-Biased
1.25E-08
1.66E-08
2.48E-08
3.72E-08
6.00E-08
Ps90%/90% (-KTL) Un-Biased
1.07E-08
1.41E-08
2.03E-08
3.03E-08
4.88E-08
Specification MIN
-3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08
7.50E-08
1.00E-07
1.75E-07
2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
36
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 1 @ +/-15V (A)
3.00E-07
2.00E-07
1.00E-07
0.00E+00
-1.00E-07
-2.00E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.15. Plot of Negative Bias Current 1 @ +/-15V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
37
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.15. Raw data for Negative Bias Current 1 @ +/-15V (A) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Bias Current 1 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.21E-08
1.59E-08
2.39E-08
3.68E-08
6.11E-08
351
1.21E-08
1.63E-08
2.41E-08
3.70E-08
6.06E-08
352
1.22E-08
1.59E-08
2.36E-08
3.69E-08
6.04E-08
353
1.12E-08
1.54E-08
2.31E-08
3.60E-08
5.95E-08
354
1.17E-08
1.61E-08
2.39E-08
3.72E-08
6.23E-08
355
1.20E-08
1.59E-08
2.36E-08
3.53E-08
5.76E-08
356
1.13E-08
1.52E-08
2.28E-08
3.45E-08
5.56E-08
357
1.19E-08
1.56E-08
2.28E-08
3.41E-08
5.52E-08
358
1.22E-08
1.61E-08
2.35E-08
3.48E-08
5.58E-08
359
1.17E-08
1.53E-08
2.24E-08
3.37E-08
5.42E-08
360
1.23E-08
1.22E-08
1.22E-08
1.22E-08
1.22E-08
361
1.26E-08
1.25E-08
1.26E-08
1.26E-08
1.26E-08
Biased Statistics
Average Biased
1.19E-08
1.59E-08
2.37E-08
3.68E-08
6.08E-08
Std Dev Biased
4.23E-10
3.33E-10
3.99E-10
4.54E-10
1.03E-09
Ps90%/90% (+KTL) Biased
1.30E-08
1.68E-08
2.48E-08
3.80E-08
6.36E-08
Ps90%/90% (-KTL) Biased
1.07E-08
1.50E-08
2.26E-08
3.55E-08
5.80E-08
Un-Biased Statistics
Average Un-Biased
1.18E-08
1.56E-08
2.30E-08
3.45E-08
5.57E-08
Std Dev Un-Biased
3.48E-10
3.76E-10
5.01E-10
6.21E-10
1.22E-09
Ps90%/90% (+KTL) Un-Biased
1.28E-08
1.66E-08
2.44E-08
3.62E-08
5.90E-08
Ps90%/90% (-KTL) Un-Biased
1.09E-08
1.46E-08
2.16E-08
3.28E-08
5.23E-08
Specification MIN
-3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08
7.50E-08
1.00E-07
1.75E-07
2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
38
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 2 @ +/-15V (A)
3.00E-07
2.00E-07
1.00E-07
0.00E+00
-1.00E-07
-2.00E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.16. Plot of Negative Bias Current 2 @ +/-15V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
39
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.16. Raw data for Negative Bias Current 2 @ +/-15V (A) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Bias Current 2 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.16E-08
1.52E-08
2.27E-08
3.51E-08
5.81E-08
351
1.12E-08
1.49E-08
2.21E-08
3.40E-08
5.58E-08
352
1.21E-08
1.58E-08
2.31E-08
3.55E-08
5.74E-08
353
1.07E-08
1.47E-08
2.25E-08
3.53E-08
5.85E-08
354
1.16E-08
1.58E-08
2.33E-08
3.63E-08
6.07E-08
355
1.15E-08
1.52E-08
2.24E-08
3.36E-08
5.47E-08
356
1.11E-08
1.48E-08
2.20E-08
3.33E-08
5.35E-08
357
1.13E-08
1.48E-08
2.16E-08
3.24E-08
5.26E-08
358
1.13E-08
1.49E-08
2.21E-08
3.30E-08
5.39E-08
359
1.15E-08
1.50E-08
2.17E-08
3.27E-08
5.27E-08
360
1.22E-08
1.22E-08
1.22E-08
1.22E-08
1.22E-08
361
1.07E-08
1.07E-08
1.06E-08
1.06E-08
1.06E-08
Biased Statistics
Average Biased
1.14E-08
1.53E-08
2.27E-08
3.52E-08
5.81E-08
Std Dev Biased
4.97E-10
5.17E-10
4.74E-10
8.41E-10
1.79E-09
Ps90%/90% (+KTL) Biased
1.28E-08
1.67E-08
2.40E-08
3.75E-08
6.30E-08
Ps90%/90% (-KTL) Biased
1.01E-08
1.38E-08
2.14E-08
3.29E-08
5.32E-08
Un-Biased Statistics
Average Un-Biased
1.13E-08
1.50E-08
2.20E-08
3.30E-08
5.35E-08
Std Dev Un-Biased
1.56E-10
1.76E-10
3.10E-10
4.56E-10
8.85E-10
Ps90%/90% (+KTL) Un-Biased
1.18E-08
1.54E-08
2.28E-08
3.42E-08
5.59E-08
Ps90%/90% (-KTL) Un-Biased
1.09E-08
1.45E-08
2.11E-08
3.17E-08
5.10E-08
Specification MIN
-3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08
7.50E-08
1.00E-07
1.75E-07
2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
40
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 3 @ +/-15V (A)
3.00E-07
2.00E-07
1.00E-07
0.00E+00
-1.00E-07
-2.00E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.17. Plot of Negative Bias Current 3 @ +/-15V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
41
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.17. Raw data for Negative Bias Current 3 @ +/-15V (A) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Bias Current 3 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.20E-08
1.56E-08
2.33E-08
3.60E-08
5.92E-08
351
1.23E-08
1.62E-08
2.37E-08
3.64E-08
5.97E-08
352
1.19E-08
1.56E-08
2.28E-08
3.49E-08
5.69E-08
353
1.11E-08
1.51E-08
2.31E-08
3.63E-08
6.03E-08
354
1.13E-08
1.57E-08
2.28E-08
3.55E-08
5.96E-08
355
1.19E-08
1.56E-08
2.29E-08
3.43E-08
5.55E-08
356
1.20E-08
1.60E-08
2.37E-08
3.56E-08
5.73E-08
357
1.17E-08
1.52E-08
2.21E-08
3.32E-08
5.34E-08
358
1.15E-08
1.52E-08
2.24E-08
3.37E-08
5.48E-08
359
1.23E-08
1.60E-08
2.33E-08
3.49E-08
5.62E-08
360
1.28E-08
1.27E-08
1.28E-08
1.27E-08
1.27E-08
361
1.12E-08
1.10E-08
1.10E-08
1.11E-08
1.11E-08
Biased Statistics
Average Biased
1.17E-08
1.56E-08
2.32E-08
3.58E-08
5.91E-08
Std Dev Biased
5.27E-10
3.82E-10
3.62E-10
5.92E-10
1.29E-09
Ps90%/90% (+KTL) Biased
1.32E-08
1.67E-08
2.41E-08
3.74E-08
6.27E-08
Ps90%/90% (-KTL) Biased
1.03E-08
1.46E-08
2.22E-08
3.42E-08
5.56E-08
Un-Biased Statistics
Average Un-Biased
1.19E-08
1.56E-08
2.29E-08
3.43E-08
5.54E-08
Std Dev Un-Biased
3.38E-10
4.24E-10
6.40E-10
9.88E-10
1.47E-09
Ps90%/90% (+KTL) Un-Biased
1.28E-08
1.68E-08
2.46E-08
3.71E-08
5.95E-08
Ps90%/90% (-KTL) Un-Biased
1.09E-08
1.44E-08
2.11E-08
3.16E-08
5.14E-08
Specification MIN
-3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08
7.50E-08
1.00E-07
1.75E-07
2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
42
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 4 @ +/-15V (A)
3.00E-07
2.00E-07
1.00E-07
0.00E+00
-1.00E-07
-2.00E-07
-3.00E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.18. Plot of Negative Bias Current 4 @ +/-15V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
43
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.18. Raw data for Negative Bias Current 4 @ +/-15V (A) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Bias Current 4 @ +/-15V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.17E-08
1.53E-08
2.29E-08
3.54E-08
5.88E-08
351
1.11E-08
1.49E-08
2.21E-08
3.41E-08
5.60E-08
352
1.11E-08
1.46E-08
2.18E-08
3.39E-08
5.57E-08
353
1.09E-08
1.49E-08
2.26E-08
3.53E-08
5.86E-08
354
1.13E-08
1.47E-08
2.30E-08
3.58E-08
6.00E-08
355
1.16E-08
1.55E-08
2.29E-08
3.43E-08
5.56E-08
356
1.16E-08
1.56E-08
2.31E-08
3.48E-08
5.58E-08
357
1.21E-08
1.59E-08
2.32E-08
3.45E-08
5.53E-08
358
1.13E-08
1.49E-08
2.17E-08
3.25E-08
5.22E-08
359
1.14E-08
1.49E-08
2.17E-08
3.26E-08
5.25E-08
360
1.19E-08
1.19E-08
1.19E-08
1.19E-08
1.19E-08
361
1.17E-08
1.15E-08
1.15E-08
1.16E-08
1.16E-08
Biased Statistics
Average Biased
1.12E-08
1.49E-08
2.25E-08
3.49E-08
5.78E-08
Std Dev Biased
2.84E-10
2.53E-10
5.15E-10
8.68E-10
1.89E-09
Ps90%/90% (+KTL) Biased
1.20E-08
1.56E-08
2.39E-08
3.73E-08
6.30E-08
Ps90%/90% (-KTL) Biased
1.04E-08
1.42E-08
2.11E-08
3.25E-08
5.26E-08
Un-Biased Statistics
Average Un-Biased
1.16E-08
1.54E-08
2.25E-08
3.38E-08
5.43E-08
Std Dev Un-Biased
3.14E-10
4.38E-10
7.25E-10
1.10E-09
1.77E-09
Ps90%/90% (+KTL) Un-Biased
1.25E-08
1.66E-08
2.45E-08
3.68E-08
5.92E-08
Ps90%/90% (-KTL) Un-Biased
1.08E-08
1.42E-08
2.05E-08
3.07E-08
4.94E-08
Specification MIN
-3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
3.00E-08
7.50E-08
1.00E-07
1.75E-07
2.50E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
44
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio 1 (dB)
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.19. Plot of Common Mode Rejection Ratio 1 (dB) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
45
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.19. Raw data for Common Mode Rejection Ratio 1 (dB) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Common Mode Rejection Ratio 1 (dB)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.14E+02 1.12E+02 1.11E+02 1.10E+02 1.09E+02
351 1.12E+02 1.10E+02 1.09E+02 1.09E+02 1.08E+02
352 1.17E+02 1.14E+02 1.13E+02 1.11E+02 1.10E+02
353 1.16E+02 1.13E+02 1.12E+02 1.11E+02 1.10E+02
354 1.12E+02 1.14E+02 1.09E+02 1.09E+02 1.08E+02
355 1.14E+02 1.12E+02 1.10E+02 1.09E+02 1.07E+02
356 1.13E+02 1.11E+02 1.10E+02 1.09E+02 1.08E+02
357 1.08E+02 1.07E+02 1.06E+02 1.06E+02 1.05E+02
358 1.09E+02 1.08E+02 1.07E+02 1.06E+02 1.06E+02
359 1.09E+02 1.08E+02 1.08E+02 1.07E+02 1.06E+02
360 1.17E+02 1.17E+02 1.17E+02 1.17E+02 1.17E+02
361 1.15E+02 1.15E+02 1.15E+02 1.15E+02 1.15E+02
Biased Statistics
Average Biased
1.14E+02 1.13E+02 1.11E+02 1.10E+02 1.09E+02
Std Dev Biased
2.37E+00 1.59E+00 1.62E+00 1.31E+00 1.14E+00
Ps90%/90% (+KTL) Biased
1.21E+02 1.17E+02 1.15E+02 1.14E+02 1.12E+02
Ps90%/90% (-KTL) Biased
1.08E+02 1.08E+02 1.07E+02 1.06E+02 1.06E+02
Un-Biased Statistics
Average Un-Biased
1.11E+02 1.09E+02 1.08E+02 1.07E+02 1.06E+02
Std Dev Un-Biased
2.54E+00 2.13E+00 1.81E+00 1.61E+00 1.36E+00
Ps90%/90% (+KTL) Un-Biased
1.18E+02 1.15E+02 1.13E+02 1.12E+02 1.10E+02
Ps90%/90% (-KTL) Un-Biased
1.04E+02 1.04E+02 1.03E+02 1.03E+02 1.03E+02
Specification MIN
9.70E+01 9.70E+01 9.40E+01 9.00E+01 8.60E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
46
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio 2 (dB)
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.20. Plot of Common Mode Rejection Ratio 2 (dB) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
47
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.20. Raw data for Common Mode Rejection Ratio 2 (dB) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Common Mode Rejection Ratio 2 (dB)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.16E+02 1.13E+02 1.12E+02 1.11E+02 1.10E+02
351 1.32E+02 1.20E+02 1.18E+02 1.16E+02 1.14E+02
352 1.22E+02 1.17E+02 1.15E+02 1.14E+02 1.13E+02
353 1.33E+02 1.22E+02 1.19E+02 1.16E+02 1.13E+02
354 1.29E+02 1.17E+02 1.27E+02 1.22E+02 1.18E+02
355 1.13E+02 1.11E+02 1.09E+02 1.08E+02 1.06E+02
356 1.46E+02 1.24E+02 1.20E+02 1.17E+02 1.13E+02
357 1.12E+02 1.11E+02 1.09E+02 1.08E+02 1.07E+02
358 1.14E+02 1.12E+02 1.11E+02 1.10E+02 1.08E+02
359 1.16E+02 1.14E+02 1.12E+02 1.11E+02 1.09E+02
360 1.36E+02 1.33E+02 1.33E+02 1.34E+02 1.33E+02
361 1.22E+02 1.22E+02 1.22E+02 1.22E+02 1.22E+02
Biased Statistics
Average Biased
1.27E+02 1.18E+02 1.18E+02 1.16E+02 1.13E+02
Std Dev Biased
7.11E+00 3.47E+00 5.54E+00 4.01E+00 2.88E+00
Ps90%/90% (+KTL) Biased
1.46E+02 1.27E+02 1.33E+02 1.27E+02 1.21E+02
Ps90%/90% (-KTL) Biased
1.07E+02 1.08E+02 1.03E+02 1.05E+02 1.05E+02
Un-Biased Statistics
Average Un-Biased
1.20E+02 1.14E+02 1.12E+02 1.11E+02 1.09E+02
Std Dev Un-Biased
1.45E+01 5.66E+00 4.36E+00 3.50E+00 2.66E+00
Ps90%/90% (+KTL) Un-Biased
1.60E+02 1.30E+02 1.24E+02 1.20E+02 1.16E+02
Ps90%/90% (-KTL) Un-Biased
8.07E+01 9.87E+01 1.00E+02 1.01E+02 1.02E+02
Specification MIN
9.70E+01 9.70E+01 9.40E+01 9.00E+01 8.60E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
48
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio 3 (dB)
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.21. Plot of Common Mode Rejection Ratio 3 (dB) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
49
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.21. Raw data for Common Mode Rejection Ratio 3 (dB) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Common Mode Rejection Ratio 3 (dB)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.10E+02 1.08E+02 1.08E+02 1.07E+02 1.06E+02
351 1.13E+02 1.11E+02 1.10E+02 1.09E+02 1.08E+02
352 1.10E+02 1.09E+02 1.08E+02 1.08E+02 1.07E+02
353 1.13E+02 1.11E+02 1.10E+02 1.09E+02 1.08E+02
354 1.17E+02 1.09E+02 1.13E+02 1.12E+02 1.11E+02
355 1.18E+02 1.15E+02 1.12E+02 1.11E+02 1.09E+02
356 1.17E+02 1.14E+02 1.13E+02 1.11E+02 1.09E+02
357 1.10E+02 1.09E+02 1.08E+02 1.07E+02 1.06E+02
358 1.08E+02 1.08E+02 1.07E+02 1.06E+02 1.05E+02
359 1.12E+02 1.11E+02 1.10E+02 1.09E+02 1.07E+02
360 1.14E+02 1.14E+02 1.14E+02 1.14E+02 1.14E+02
361 1.17E+02 1.17E+02 1.17E+02 1.17E+02 1.17E+02
Biased Statistics
Average Biased
1.13E+02 1.10E+02 1.10E+02 1.09E+02 1.08E+02
Std Dev Biased
2.87E+00 1.19E+00 2.14E+00 2.04E+00 1.81E+00
Ps90%/90% (+KTL) Biased
1.21E+02 1.13E+02 1.16E+02 1.15E+02 1.13E+02
Ps90%/90% (-KTL) Biased
1.05E+02 1.06E+02 1.04E+02 1.04E+02 1.03E+02
Un-Biased Statistics
Average Un-Biased
1.13E+02 1.11E+02 1.10E+02 1.09E+02 1.07E+02
Std Dev Un-Biased
4.53E+00 3.27E+00 2.63E+00 2.27E+00 1.75E+00
Ps90%/90% (+KTL) Un-Biased
1.26E+02 1.20E+02 1.17E+02 1.15E+02 1.12E+02
Ps90%/90% (-KTL) Un-Biased
1.01E+02 1.02E+02 1.03E+02 1.02E+02 1.02E+02
Specification MIN
9.70E+01 9.70E+01 9.40E+01 9.00E+01 8.60E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
50
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio 4 (dB)
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.22. Plot of Common Mode Rejection Ratio 4 (dB) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
51
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.22. Raw data for Common Mode Rejection Ratio 4 (dB) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Common Mode Rejection Ratio 4 (dB)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.23E+02 1.17E+02 1.16E+02 1.14E+02 1.12E+02
351 1.09E+02 1.08E+02 1.07E+02 1.06E+02 1.06E+02
352 1.13E+02 1.10E+02 1.09E+02 1.08E+02 1.07E+02
353 1.18E+02 1.15E+02 1.13E+02 1.12E+02 1.11E+02
354 1.22E+02 1.11E+02 1.15E+02 1.13E+02 1.12E+02
355 1.16E+02 1.13E+02 1.12E+02 1.10E+02 1.08E+02
356 1.19E+02 1.26E+02 1.42E+02 1.27E+02 1.18E+02
357 1.19E+02 1.15E+02 1.13E+02 1.11E+02 1.09E+02
358 1.23E+02 1.17E+02 1.15E+02 1.13E+02 1.10E+02
359 1.15E+02 1.13E+02 1.11E+02 1.10E+02 1.08E+02
360 1.28E+02 1.27E+02 1.28E+02 1.28E+02 1.28E+02
361 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02
Biased Statistics
Average Biased
1.17E+02 1.12E+02 1.12E+02 1.11E+02 1.09E+02
Std Dev Biased
6.23E+00 3.97E+00 3.85E+00 3.33E+00 2.80E+00
Ps90%/90% (+KTL) Biased
1.34E+02 1.23E+02 1.23E+02 1.20E+02 1.17E+02
Ps90%/90% (-KTL) Biased
9.99E+01 1.01E+02 1.02E+02 1.02E+02 1.02E+02
Un-Biased Statistics
Average Un-Biased
1.18E+02 1.17E+02 1.19E+02 1.14E+02 1.11E+02
Std Dev Un-Biased
2.84E+00 5.24E+00 1.32E+01 7.51E+00 4.08E+00
Ps90%/90% (+KTL) Un-Biased
1.26E+02 1.31E+02 1.55E+02 1.35E+02 1.22E+02
Ps90%/90% (-KTL) Un-Biased
1.11E+02 1.02E+02 8.25E+01 9.35E+01 9.93E+01
Specification MIN
9.70E+01 9.70E+01 9.40E+01 9.00E+01 8.60E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
52
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio 1 (dB)
1.60E+02
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.23. Plot of Power Supply Rejection Ratio 1 (dB) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
53
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.23. Raw data for Power Supply Rejection Ratio 1 (dB) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Power Supply Rejection Ratio 1 (dB)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.47E+02 1.33E+02 1.31E+02 1.25E+02 1.21E+02
351 1.36E+02 1.33E+02 1.30E+02 1.25E+02 1.22E+02
352 1.33E+02 1.39E+02 1.53E+02 1.35E+02 1.25E+02
353 1.24E+02 1.26E+02 1.28E+02 1.32E+02 1.71E+02
354 1.43E+02 1.41E+02 1.29E+02 1.26E+02 1.21E+02
355 1.55E+02 1.44E+02 1.34E+02 1.28E+02 1.21E+02
356 1.29E+02 1.29E+02 1.34E+02 1.50E+02 1.28E+02
357 1.38E+02 1.46E+02 1.41E+02 1.35E+02 1.26E+02
358 1.22E+02 1.21E+02 1.20E+02 1.18E+02 1.14E+02
359 1.26E+02 1.24E+02 1.22E+02 1.20E+02 1.16E+02
360 1.25E+02 1.27E+02 1.27E+02 1.27E+02 1.27E+02
361 1.44E+02 1.43E+02 1.43E+02 1.46E+02 1.41E+02
Biased Statistics
Average Biased
1.37E+02 1.34E+02 1.34E+02 1.29E+02 1.32E+02
Std Dev Biased
9.02E+00 5.74E+00 1.08E+01 4.25E+00 2.21E+01
Ps90%/90% (+KTL) Biased
1.61E+02 1.50E+02 1.64E+02 1.40E+02 1.93E+02
Ps90%/90% (-KTL) Biased
1.12E+02 1.19E+02 1.05E+02 1.17E+02 7.14E+01
Un-Biased Statistics
Average Un-Biased
1.34E+02 1.33E+02 1.30E+02 1.30E+02 1.21E+02
Std Dev Un-Biased
1.31E+01 1.16E+01 9.08E+00 1.27E+01 6.23E+00
Ps90%/90% (+KTL) Un-Biased
1.70E+02 1.65E+02 1.55E+02 1.65E+02 1.38E+02
Ps90%/90% (-KTL) Un-Biased
9.78E+01 1.01E+02 1.05E+02 9.53E+01 1.04E+02
Specification MIN
1.00E+02 9.80E+01 9.40E+01 8.60E+01 8.00E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
54
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio 2 (dB)
1.60E+02
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.24. Plot of Power Supply Rejection Ratio 2 (dB) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
55
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.24. Raw data for Power Supply Rejection Ratio 2 (dB) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Power Supply Rejection Ratio 2 (dB)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.31E+02 1.35E+02 1.44E+02 1.41E+02 1.28E+02
351 1.26E+02 1.29E+02 1.32E+02 1.48E+02 1.31E+02
352 1.28E+02 1.32E+02 1.36E+02 1.48E+02 1.32E+02
353 1.20E+02 1.20E+02 1.21E+02 1.23E+02 1.27E+02
354 1.22E+02 1.32E+02 1.25E+02 1.28E+02 1.61E+02
355 1.45E+02 1.47E+02 1.34E+02 1.26E+02 1.20E+02
356 1.21E+02 1.22E+02 1.24E+02 1.28E+02 2.00E+02
357 1.29E+02 1.26E+02 1.25E+02 1.22E+02 1.18E+02
358 1.16E+02 1.17E+02 1.17E+02 1.17E+02 1.18E+02
359 1.44E+02 1.39E+02 1.35E+02 1.28E+02 1.21E+02
360 1.30E+02 1.30E+02 1.29E+02 1.29E+02 1.30E+02
361 1.20E+02 1.20E+02 1.20E+02 1.20E+02 1.20E+02
Biased Statistics
Average Biased
1.25E+02 1.30E+02 1.32E+02 1.38E+02 1.36E+02
Std Dev Biased
4.42E+00 5.77E+00 9.05E+00 1.15E+01 1.41E+01
Ps90%/90% (+KTL) Biased
1.37E+02 1.45E+02 1.56E+02 1.69E+02 1.74E+02
Ps90%/90% (-KTL) Biased
1.13E+02 1.14E+02 1.07E+02 1.06E+02 9.69E+01
Un-Biased Statistics
Average Un-Biased
1.31E+02 1.30E+02 1.27E+02 1.24E+02 1.35E+02
Std Dev Un-Biased
1.34E+01 1.24E+01 7.58E+00 4.81E+00 3.64E+01
Ps90%/90% (+KTL) Un-Biased
1.68E+02 1.64E+02 1.48E+02 1.37E+02 2.35E+02
Ps90%/90% (-KTL) Un-Biased
9.44E+01 9.62E+01 1.06E+02 1.11E+02 3.55E+01
Specification MIN
1.00E+02 9.80E+01 9.40E+01 8.60E+01 8.00E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
56
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio 3 (dB)
1.60E+02
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.25. Plot of Power Supply Rejection Ratio 3 (dB) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
57
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.25. Raw data for Power Supply Rejection Ratio 3 (dB) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Power Supply Rejection Ratio 3 (dB)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.21E+02 1.20E+02 1.19E+02 1.17E+02 1.15E+02
351 1.26E+02 1.24E+02 1.23E+02 1.21E+02 1.18E+02
352 1.49E+02 1.41E+02 1.37E+02 1.31E+02 1.25E+02
353 1.24E+02 1.26E+02 1.28E+02 1.30E+02 1.52E+02
354 1.25E+02 1.40E+02 1.29E+02 1.32E+02 1.43E+02
355 1.28E+02 1.31E+02 1.37E+02 1.35E+02 1.23E+02
356 1.38E+02 1.34E+02 1.29E+02 1.24E+02 1.18E+02
357 1.23E+02 1.22E+02 1.21E+02 1.20E+02 1.16E+02
358 1.46E+02 1.42E+02 1.56E+02 1.37E+02 1.27E+02
359 1.40E+02 1.32E+02 1.28E+02 1.24E+02 1.19E+02
360 1.48E+02 1.40E+02 1.39E+02 1.39E+02 1.43E+02
361 1.40E+02 1.40E+02 1.36E+02 1.36E+02 1.41E+02
Biased Statistics
Average Biased
1.29E+02 1.30E+02 1.27E+02 1.26E+02 1.31E+02
Std Dev Biased
1.16E+01 9.61E+00 6.81E+00 6.76E+00 1.62E+01
Ps90%/90% (+KTL) Biased
1.61E+02 1.57E+02 1.46E+02 1.45E+02 1.75E+02
Ps90%/90% (-KTL) Biased
9.69E+01 1.04E+02 1.09E+02 1.08E+02 8.61E+01
Un-Biased Statistics
Average Un-Biased
1.35E+02 1.32E+02 1.34E+02 1.28E+02 1.21E+02
Std Dev Un-Biased
9.32E+00 7.06E+00 1.33E+01 7.61E+00 4.41E+00
Ps90%/90% (+KTL) Un-Biased
1.61E+02 1.52E+02 1.70E+02 1.49E+02 1.33E+02
Ps90%/90% (-KTL) Un-Biased
1.09E+02 1.13E+02 9.76E+01 1.07E+02 1.09E+02
Specification MIN
1.00E+02 9.80E+01 9.40E+01 8.60E+01 8.00E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
58
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio 4 (dB)
1.60E+02
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.26. Plot of Power Supply Rejection Ratio 4 (dB) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
59
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.26. Raw data for Power Supply Rejection Ratio 4 (dB) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Power Supply Rejection Ratio 4 (dB)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.35E+02 1.43E+02 1.59E+02 1.32E+02 1.24E+02
351 1.19E+02 1.18E+02 1.17E+02 1.16E+02 1.14E+02
352 1.66E+02 1.34E+02 1.30E+02 1.26E+02 1.21E+02
353 1.27E+02 1.28E+02 1.32E+02 1.39E+02 1.33E+02
354 1.27E+02 1.36E+02 1.33E+02 1.39E+02 1.32E+02
355 1.31E+02 1.31E+02 1.39E+02 1.38E+02 1.26E+02
356 1.21E+02 1.22E+02 1.23E+02 1.28E+02 1.33E+02
357 1.32E+02 1.39E+02 1.46E+02 1.28E+02 1.20E+02
358 1.23E+02 1.25E+02 1.27E+02 1.34E+02 1.29E+02
359 1.36E+02 1.32E+02 1.28E+02 1.24E+02 1.19E+02
360 1.26E+02 1.26E+02 1.26E+02 1.26E+02 1.26E+02
361 1.34E+02 1.31E+02 1.31E+02 1.31E+02 1.32E+02
Biased Statistics
Average Biased
1.35E+02 1.32E+02 1.34E+02 1.30E+02 1.25E+02
Std Dev Biased
1.86E+01 9.31E+00 1.51E+01 9.53E+00 7.83E+00
Ps90%/90% (+KTL) Biased
1.86E+02 1.57E+02 1.76E+02 1.56E+02 1.46E+02
Ps90%/90% (-KTL) Biased
8.38E+01 1.06E+02 9.28E+01 1.04E+02 1.04E+02
Un-Biased Statistics
Average Un-Biased
1.28E+02 1.30E+02 1.33E+02 1.30E+02 1.25E+02
Std Dev Un-Biased
6.31E+00 6.74E+00 9.46E+00 5.46E+00 5.79E+00
Ps90%/90% (+KTL) Un-Biased
1.46E+02 1.48E+02 1.59E+02 1.45E+02 1.41E+02
Ps90%/90% (-KTL) Un-Biased
1.11E+02 1.11E+02 1.07E+02 1.15E+02 1.09E+02
Specification MIN
1.00E+02 9.80E+01 9.40E+01 8.60E+01 8.00E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
60
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Open Loop Gain 1 RL=10k VO=+/-10V (V/mV)
1.40E+04
1.20E+04
1.00E+04
8.00E+03
6.00E+03
4.00E+03
2.00E+03
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.27. Plot of Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
61
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.27. Raw data for Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Open Loop Gain 1 RL=10k VO=+/-10V (V/mV)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 9.86E+03 1.14E+04 6.43E+03 3.02E+03 1.30E+03
351 8.66E+03 1.02E+04 5.77E+03 2.97E+03 1.33E+03
352 9.16E+03 1.08E+04 6.37E+03 3.00E+03 1.33E+03
353 8.13E+03 1.48E+04 8.40E+03 3.98E+03 1.78E+03
354 6.49E+03 1.23E+04 1.17E+04 5.06E+03 1.69E+03
355 1.11E+04 9.29E+03 6.29E+03 3.51E+03 1.61E+03
356 8.95E+03 1.39E+04 6.74E+03 3.77E+03 1.60E+03
357 1.31E+04 7.11E+03 5.13E+03 2.83E+03 1.28E+03
358 8.53E+03 1.02E+04 6.13E+03 3.28E+03 1.30E+03
359 1.05E+04 9.12E+03 4.43E+03 3.19E+03 1.21E+03
360 8.50E+03 1.63E+04 1.69E+04 1.68E+04 1.97E+04
361 7.63E+03 2.73E+04 2.87E+04 3.12E+04 2.56E+04
Biased Statistics
Average Biased
8.46E+03 1.19E+04 7.73E+03 3.61E+03 1.49E+03
Std Dev Biased
1.27E+03 1.79E+03 2.41E+03 9.19E+02 2.30E+02
Ps90%/90% (+KTL) Biased
1.19E+04 1.68E+04 1.43E+04 6.13E+03 2.12E+03
Ps90%/90% (-KTL) Biased
4.97E+03 6.97E+03 1.11E+03 1.09E+03 8.57E+02
Un-Biased Statistics
Average Un-Biased
1.04E+04 9.92E+03 5.74E+03 3.32E+03 1.40E+03
Std Dev Un-Biased
1.84E+03 2.50E+03 9.42E+02 3.52E+02 1.92E+02
Ps90%/90% (+KTL) Un-Biased
1.55E+04 1.68E+04 8.32E+03 4.28E+03 1.93E+03
Ps90%/90% (-KTL) Un-Biased
5.39E+03 3.08E+03 3.16E+03 2.35E+03 8.75E+02
Specification MIN
1.20E+03 2.00E+02 1.00E+02 5.00E+01 2.50E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
62
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Open Loop Gain 2 RL=10k VO=+/-10V (V/mV)
1.50E+04
1.00E+04
5.00E+03
0.00E+00
-5.00E+03
-1.00E+04
-1.50E+04
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.28. Plot of Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
63
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.28. Raw data for Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Open Loop Gain 2 RL=10k VO=+/-10V (V/mV)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.03E+04 9.46E+03 5.76E+03 2.90E+03 1.36E+03
351 9.97E+03 8.25E+03 4.31E+03 2.70E+03 1.28E+03
352 1.08E+04 9.56E+03 4.90E+03 2.95E+03 1.36E+03
353 6.07E+03 2.80E+04 8.64E+03 4.16E+03 1.79E+03
354 6.30E+03 9.77E+03 1.07E+04 4.42E+03 1.67E+03
355 9.81E+03 8.29E+03 5.13E+03 2.89E+03 1.26E+03
356 9.01E+03 1.17E+04 5.59E+03 3.80E+03 1.50E+03
357 1.03E+04 7.08E+03 5.59E+03 3.23E+03 1.52E+03
358 8.61E+03 1.47E+04 6.26E+03 4.29E+03 1.62E+03
359 8.72E+03 8.59E+03 5.83E+03 2.71E+03 1.44E+03
360 8.87E+03 1.13E+04 1.19E+04 1.16E+04 1.20E+04
361 5.61E+03 5.81E+04 9.06E+04 5.75E+04 8.90E+04
Biased Statistics
Average Biased
8.68E+03 1.30E+04 6.87E+03 3.43E+03 1.49E+03
Std Dev Biased
2.30E+03 8.39E+03 2.73E+03 8.02E+02 2.22E+02
Ps90%/90% (+KTL) Biased
1.50E+04 3.60E+04 1.43E+04 5.62E+03 2.10E+03
Ps90%/90% (-KTL) Biased
2.38E+03 -1.00E+04 -6.06E+02 1.23E+03 8.82E+02
Un-Biased Statistics
Average Un-Biased
9.28E+03 1.01E+04 5.68E+03 3.39E+03 1.47E+03
Std Dev Un-Biased
7.23E+02 3.10E+03 4.11E+02 6.54E+02 1.31E+02
Ps90%/90% (+KTL) Un-Biased
1.13E+04 1.86E+04 6.81E+03 5.18E+03 1.83E+03
Ps90%/90% (-KTL) Un-Biased
7.30E+03 1.56E+03 4.55E+03 1.59E+03 1.11E+03
Specification MIN
1.20E+03 2.00E+02 1.00E+02 5.00E+01 2.50E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
64
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Open Loop Gain 3 RL=10k VO=+/-10V (V/mV)
2.00E+04
1.50E+04
1.00E+04
5.00E+03
0.00E+00
-5.00E+03
-1.00E+04
-1.50E+04
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.29. Plot of Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
65
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.29. Raw data for Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Open Loop Gain 3 RL=10k VO=+/-10V (V/mV)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 9.58E+03 1.25E+04 5.81E+03 2.84E+03 1.21E+03
351 9.72E+03 1.01E+04 6.55E+03 3.32E+03 1.34E+03
352 1.29E+04 7.10E+03 4.89E+03 2.82E+03 1.43E+03
353 6.71E+03 2.72E+04 9.04E+03 4.62E+03 1.95E+03
354 7.77E+03 7.75E+03 9.21E+03 3.68E+03 1.62E+03
355 1.16E+04 8.88E+03 5.12E+03 3.02E+03 1.45E+03
356 7.70E+03 2.52E+04 1.17E+04 4.72E+03 1.81E+03
357 9.01E+03 9.21E+03 5.65E+03 3.40E+03 1.46E+03
358 6.86E+03 1.39E+04 8.17E+03 4.42E+03 1.73E+03
359 8.27E+03 1.50E+04 8.52E+03 3.83E+03 1.62E+03
360 9.86E+03 1.18E+04 1.23E+04 1.37E+04 1.30E+04
361 5.36E+03 4.52E+04 3.20E+04 4.46E+04 3.55E+04
Biased Statistics
Average Biased
9.35E+03 1.29E+04 7.10E+03 3.46E+03 1.51E+03
Std Dev Biased
2.38E+03 8.27E+03 1.94E+03 7.43E+02 2.85E+02
Ps90%/90% (+KTL) Biased
1.59E+04 3.56E+04 1.24E+04 5.50E+03 2.29E+03
Ps90%/90% (-KTL) Biased
2.83E+03 -9.73E+03 1.78E+03 1.42E+03 7.29E+02
Un-Biased Statistics
Average Un-Biased
8.68E+03 1.44E+04 7.83E+03 3.88E+03 1.61E+03
Std Dev Un-Biased
1.81E+03 6.61E+03 2.62E+03 7.02E+02 1.58E+02
Ps90%/90% (+KTL) Un-Biased
1.36E+04 3.26E+04 1.50E+04 5.80E+03 2.05E+03
Ps90%/90% (-KTL) Un-Biased
3.73E+03 -3.70E+03 6.52E+02 1.95E+03 1.18E+03
Specification MIN
1.20E+03 2.00E+02 1.00E+02 5.00E+01 2.50E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
66
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Open Loop Gain 4 RL=10k VO=+/-10V (V/mV)
1.20E+04
1.00E+04
8.00E+03
6.00E+03
4.00E+03
2.00E+03
0.00E+00
-2.00E+03
-4.00E+03
-6.00E+03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.30. Plot of Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
67
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.30. Raw data for Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Open Loop Gain 4 RL=10k VO=+/-10V (V/mV)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 9.70E+03 1.18E+04 5.33E+03 2.76E+03 1.34E+03
351 1.03E+04 8.47E+03 4.64E+03 2.92E+03 1.26E+03
352 1.03E+04 6.90E+03 4.74E+03 2.88E+03 1.32E+03
353 9.34E+03 1.84E+04 7.05E+03 3.82E+03 1.65E+03
354 6.73E+03 8.09E+03 1.04E+04 3.85E+03 1.69E+03
355 9.84E+03 9.16E+03 5.25E+03 3.02E+03 1.28E+03
356 7.22E+03 2.07E+04 8.51E+03 4.74E+03 1.68E+03
357 9.10E+03 1.03E+04 5.62E+03 3.07E+03 1.32E+03
358 1.27E+04 7.02E+03 4.82E+03 2.59E+03 1.18E+03
359 1.04E+04 8.66E+03 4.61E+03 2.69E+03 1.18E+03
360 9.53E+03 1.40E+04 1.45E+04 1.36E+04 1.43E+04
361 1.06E+04 9.42E+03 9.55E+03 9.53E+03 9.73E+03
Biased Statistics
Average Biased
9.28E+03 1.07E+04 6.44E+03 3.25E+03 1.45E+03
Std Dev Biased
1.48E+03 4.64E+03 2.42E+03 5.42E+02 2.01E+02
Ps90%/90% (+KTL) Biased
1.33E+04 2.35E+04 1.31E+04 4.73E+03 2.00E+03
Ps90%/90% (-KTL) Biased
5.21E+03 -2.00E+03 -2.10E+02 1.76E+03 9.01E+02
Un-Biased Statistics
Average Un-Biased
9.84E+03 1.12E+04 5.76E+03 3.22E+03 1.32E+03
Std Dev Un-Biased
1.98E+03 5.45E+03 1.58E+03 8.73E+02 2.06E+02
Ps90%/90% (+KTL) Un-Biased
1.53E+04 2.61E+04 1.01E+04 5.61E+03 1.89E+03
Ps90%/90% (-KTL) Un-Biased
4.40E+03 -3.78E+03 1.42E+03 8.26E+02 7.59E+02
Specification MIN
1.20E+03 2.00E+02 1.00E+02 5.00E+01 2.50E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
68
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 1 @ +/-15V (V)
1.42E+01
1.40E+01
1.38E+01
1.36E+01
1.34E+01
1.32E+01
1.30E+01
1.28E+01
1.26E+01
1.24E+01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.31. Plot of Positive Output Voltage 1 @ +/-15V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
69
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.31. Raw data for Positive Output Voltage 1 @ +/-15V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 1 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
351 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
352 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
353 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
354 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
355 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
356 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
357 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
358 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
359 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
360 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
361 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Biased Statistics
Average Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Std Dev Biased
5.03E-03
4.69E-03
5.37E-03
5.36E-03
5.94E-03
Ps90%/90% (+KTL) Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Ps90%/90% (-KTL) Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Un-Biased Statistics
Average Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Std Dev Un-Biased
2.45E-03
2.86E-03
2.86E-03
2.70E-03
2.68E-03
Ps90%/90% (+KTL) Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Ps90%/90% (-KTL) Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Specification MIN
1.25E+01 1.25E+01 1.25E+01 1.25E+01 1.25E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
70
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 2 @ +/-15V (V)
1.42E+01
1.40E+01
1.38E+01
1.36E+01
1.34E+01
1.32E+01
1.30E+01
1.28E+01
1.26E+01
1.24E+01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.32. Plot of Positive Output Voltage 2 @ +/-15V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
71
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.32. Raw data for Positive Output Voltage 2 @ +/-15V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 2 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
351 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
352 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
353 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
354 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
355 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
356 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
357 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
358 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
359 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
360 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
361 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Biased Statistics
Average Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Std Dev Biased
4.88E-03
5.76E-03
6.00E-03
5.67E-03
6.47E-03
Ps90%/90% (+KTL) Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Ps90%/90% (-KTL) Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Un-Biased Statistics
Average Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Std Dev Un-Biased
2.86E-03
2.61E-03
2.28E-03
3.16E-03
3.16E-03
Ps90%/90% (+KTL) Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Ps90%/90% (-KTL) Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Specification MIN
1.25E+01 1.25E+01 1.25E+01 1.25E+01 1.25E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
72
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 3 @ +/-15V (V)
1.42E+01
1.40E+01
1.38E+01
1.36E+01
1.34E+01
1.32E+01
1.30E+01
1.28E+01
1.26E+01
1.24E+01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.33. Plot of Positive Output Voltage 3 @ +/-15V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
73
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.33. Raw data for Positive Output Voltage 3 @ +/-15V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 3 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
351 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
352 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
353 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
354 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
355 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
356 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
357 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
358 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
359 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
360 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
361 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Biased Statistics
Average Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Std Dev Biased
5.02E-03
5.40E-03
5.43E-03
5.54E-03
5.89E-03
Ps90%/90% (+KTL) Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Ps90%/90% (-KTL) Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Un-Biased Statistics
Average Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Std Dev Un-Biased
3.03E-03
3.49E-03
3.16E-03
3.74E-03
3.51E-03
Ps90%/90% (+KTL) Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Ps90%/90% (-KTL) Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Specification MIN
1.25E+01 1.25E+01 1.25E+01 1.25E+01 1.25E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
74
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 4 @ +/-15V (V)
1.42E+01
1.40E+01
1.38E+01
1.36E+01
1.34E+01
1.32E+01
1.30E+01
1.28E+01
1.26E+01
1.24E+01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.34. Plot of Positive Output Voltage 4 @ +/-15V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
75
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.34. Raw data for Positive Output Voltage 4 @ +/-15V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 4 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
351 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
352 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
353 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
354 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
355 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
356 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
357 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
358 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
359 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
360 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
361 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Biased Statistics
Average Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Std Dev Biased
5.54E-03
5.20E-03
5.90E-03
5.90E-03
6.61E-03
Ps90%/90% (+KTL) Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Ps90%/90% (-KTL) Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.40E+01
Un-Biased Statistics
Average Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Std Dev Un-Biased
2.70E-03
2.45E-03
2.68E-03
2.45E-03
2.49E-03
Ps90%/90% (+KTL) Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Ps90%/90% (-KTL) Un-Biased
1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01
Specification MIN
1.25E+01 1.25E+01 1.25E+01 1.25E+01 1.25E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
76
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage 1 @ +/-15V (V)
-1.20E+01
-1.25E+01
-1.30E+01
-1.35E+01
-1.40E+01
-1.45E+01
-1.50E+01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.35. Plot of Negative Output Voltage 1 @ +/-15V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
77
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.35. Raw data for Negative Output Voltage 1 @ +/-15V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Output Voltage 1 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
351 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
352 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
353 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
354 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
355 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
356 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
357 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
358 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
359 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
360 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
361 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
Biased Statistics
Average Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Std Dev Biased
3.74E-03
2.95E-03
2.61E-03
2.61E-03
2.28E-03
Ps90%/90% (+KTL) Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Ps90%/90% (-KTL) Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
Un-Biased Statistics
Average Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Std Dev Un-Biased
2.19E-03
1.67E-03
1.95E-03
2.05E-03
2.45E-03
Ps90%/90% (+KTL) Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Ps90%/90% (-KTL) Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
Specification MAX
-1.25E+01 -1.25E+01 -1.25E+01 -1.25E+01 -1.25E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
78
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage 2 @ +/-15V (V)
-1.20E+01
-1.25E+01
-1.30E+01
-1.35E+01
-1.40E+01
-1.45E+01
-1.50E+01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.36. Plot of Negative Output Voltage 2 @ +/-15V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
79
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.36. Raw data for Negative Output Voltage 2 @ +/-15V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Output Voltage 2 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
351 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
352 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
353 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
354 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
355 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
356 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
357 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
358 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
359 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
360 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
361 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
Biased Statistics
Average Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Std Dev Biased
1.67E-03
1.14E-03
8.37E-04
8.37E-04
7.07E-04
Ps90%/90% (+KTL) Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.44E+01
Ps90%/90% (-KTL) Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Un-Biased Statistics
Average Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Std Dev Un-Biased
1.82E-03
1.52E-03
2.30E-03
2.19E-03
1.64E-03
Ps90%/90% (+KTL) Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.44E+01
Ps90%/90% (-KTL) Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Specification MAX
-1.25E+01 -1.25E+01 -1.25E+01 -1.25E+01 -1.25E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
80
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage 3 @ +/-15V (V)
-1.20E+01
-1.25E+01
-1.30E+01
-1.35E+01
-1.40E+01
-1.45E+01
-1.50E+01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.37. Plot of Negative Output Voltage 3 @ +/-15V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
81
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.37. Raw data for Negative Output Voltage 3 @ +/-15V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Output Voltage 3 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
351 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
352 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
353 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
354 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
355 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
356 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
357 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
358 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
359 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
360 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
361 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
Biased Statistics
Average Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Std Dev Biased
1.34E-03
1.14E-03
8.37E-04
8.94E-04
1.10E-03
Ps90%/90% (+KTL) Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Ps90%/90% (-KTL) Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
Un-Biased Statistics
Average Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
Std Dev Un-Biased
2.17E-03
2.05E-03
2.07E-03
2.05E-03
1.95E-03
Ps90%/90% (+KTL) Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Ps90%/90% (-KTL) Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
Specification MAX
-1.25E+01 -1.25E+01 -1.25E+01 -1.25E+01 -1.25E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
82
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Output Voltage 4 @ +/-15V (V)
-1.20E+01
-1.25E+01
-1.30E+01
-1.35E+01
-1.40E+01
-1.45E+01
-1.50E+01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.38. Plot of Negative Output Voltage 4 @ +/-15V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
83
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.38. Raw data for Negative Output Voltage 4 @ +/-15V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Output Voltage 4 @ +/-15V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
351 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
352 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
353 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
354 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
355 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
356 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
357 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
358 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
359 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
360 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
361 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
Biased Statistics
Average Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Std Dev Biased
3.74E-03
3.13E-03
3.29E-03
3.29E-03
3.13E-03
Ps90%/90% (+KTL) Biased
-1.44E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.44E+01
Ps90%/90% (-KTL) Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01
Un-Biased Statistics
Average Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Std Dev Un-Biased
2.30E-03
1.48E-03
2.05E-03
2.17E-03
2.24E-03
Ps90%/90% (+KTL) Un-Biased
-1.44E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.44E+01
Ps90%/90% (-KTL) Un-Biased
-1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01
Specification MAX
-1.25E+01 -1.25E+01 -1.25E+01 -1.25E+01 -1.25E+01
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
84
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Slew Rate 1 @ +/-15V (V/us)
6.00E-01
5.00E-01
4.00E-01
3.00E-01
2.00E-01
1.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.39. Plot of Positive Slew Rate 1 @ +/-15V (V/us) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
85
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.39. Raw data for Positive Slew Rate 1 @ +/-15V (V/us) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Slew Rate 1 @ +/-15V (V/us)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
4.75E-01
4.69E-01
4.34E-01
4.20E-01
3.71E-01
351
4.60E-01
4.49E-01
4.33E-01
4.13E-01
3.65E-01
352
5.11E-01
4.96E-01
4.80E-01
4.49E-01
4.01E-01
353
5.23E-01
4.96E-01
4.80E-01
4.52E-01
4.03E-01
354
5.25E-01
4.90E-01
4.85E-01
4.63E-01
4.02E-01
355
5.21E-01
5.01E-01
4.74E-01
4.63E-01
4.06E-01
356
4.97E-01
4.79E-01
4.74E-01
4.34E-01
3.75E-01
357
4.89E-01
4.72E-01
4.56E-01
4.34E-01
3.78E-01
358
4.58E-01
4.51E-01
4.26E-01
4.03E-01
3.56E-01
359
4.72E-01
4.45E-01
4.37E-01
4.11E-01
3.56E-01
360
4.78E-01
4.67E-01
4.67E-01
4.62E-01
4.74E-01
361
4.68E-01
4.70E-01
4.65E-01
4.57E-01
4.70E-01
Biased Statistics
Average Biased
4.99E-01
4.80E-01
4.62E-01
4.39E-01
3.88E-01
Std Dev Biased
2.95E-02
2.06E-02
2.65E-02
2.17E-02
1.88E-02
Ps90%/90% (+KTL) Biased
5.80E-01
5.36E-01
5.35E-01
4.99E-01
4.40E-01
Ps90%/90% (-KTL) Biased
4.18E-01
4.24E-01
3.90E-01
3.80E-01
3.37E-01
Un-Biased Statistics
Average Un-Biased
4.87E-01
4.70E-01
4.53E-01
4.29E-01
3.74E-01
Std Dev Un-Biased
2.41E-02
2.25E-02
2.17E-02
2.35E-02
2.05E-02
Ps90%/90% (+KTL) Un-Biased
5.54E-01
5.31E-01
5.13E-01
4.93E-01
4.31E-01
Ps90%/90% (-KTL) Un-Biased
4.21E-01
4.08E-01
3.94E-01
3.65E-01
3.18E-01
Specification MIN
2.00E-01
1.20E-01
1.10E-01
7.00E-02
1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
86
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
5.00E-01
Positive Slew Rate 2 @ +/-15V (V/us)
4.50E-01
4.00E-01
3.50E-01
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.40. Plot of Positive Slew Rate 2 @ +/-15V (V/us) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
87
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.40. Raw data for Positive Slew Rate 2 @ +/-15V (V/us) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Slew Rate 2 @ +/-15V (V/us)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
4.52E-01
4.25E-01
4.22E-01
3.97E-01
3.47E-01
351
4.51E-01
4.30E-01
4.12E-01
3.91E-01
3.44E-01
352
4.47E-01
4.38E-01
4.19E-01
3.95E-01
3.52E-01
353
4.95E-01
4.63E-01
4.52E-01
4.24E-01
3.74E-01
354
4.71E-01
4.39E-01
4.36E-01
4.06E-01
3.58E-01
355
4.78E-01
4.77E-01
4.56E-01
4.20E-01
3.78E-01
356
4.70E-01
4.56E-01
4.42E-01
4.04E-01
3.56E-01
357
4.65E-01
4.37E-01
4.25E-01
3.96E-01
3.44E-01
358
4.98E-01
4.73E-01
4.65E-01
4.29E-01
3.77E-01
359
4.69E-01
4.47E-01
4.30E-01
4.06E-01
3.56E-01
360
4.44E-01
4.34E-01
4.37E-01
4.38E-01
4.39E-01
361
5.00E-01
4.83E-01
4.81E-01
4.84E-01
4.81E-01
Biased Statistics
Average Biased
4.63E-01
4.39E-01
4.28E-01
4.03E-01
3.55E-01
Std Dev Biased
2.01E-02
1.46E-02
1.59E-02
1.32E-02
1.19E-02
Ps90%/90% (+KTL) Biased
5.18E-01
4.79E-01
4.72E-01
4.39E-01
3.88E-01
Ps90%/90% (-KTL) Biased
4.08E-01
3.99E-01
3.85E-01
3.67E-01
3.22E-01
Un-Biased Statistics
Average Un-Biased
4.76E-01
4.58E-01
4.44E-01
4.11E-01
3.62E-01
Std Dev Un-Biased
1.32E-02
1.70E-02
1.69E-02
1.33E-02
1.48E-02
Ps90%/90% (+KTL) Un-Biased
5.12E-01
5.05E-01
4.90E-01
4.47E-01
4.03E-01
Ps90%/90% (-KTL) Un-Biased
4.40E-01
4.11E-01
3.97E-01
3.75E-01
3.22E-01
Specification MIN
2.00E-01
1.20E-01
1.10E-01
7.00E-02
1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
88
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Slew Rate 3 @ +/-15V (V/us)
6.00E-01
5.00E-01
4.00E-01
3.00E-01
2.00E-01
1.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.41. Plot of Positive Slew Rate 3 @ +/-15V (V/us) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
89
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.41. Raw data for Positive Slew Rate 3 @ +/-15V (V/us) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Slew Rate 3 @ +/-15V (V/us)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
4.73E-01
4.49E-01
4.43E-01
4.16E-01
3.71E-01
351
4.74E-01
4.48E-01
4.41E-01
4.17E-01
3.68E-01
352
4.77E-01
4.54E-01
4.50E-01
4.23E-01
3.77E-01
353
5.15E-01
4.89E-01
4.81E-01
4.48E-01
4.03E-01
354
4.99E-01
4.61E-01
4.67E-01
4.30E-01
3.78E-01
355
5.13E-01
4.98E-01
4.79E-01
4.51E-01
4.02E-01
356
4.97E-01
4.80E-01
4.51E-01
4.29E-01
3.80E-01
357
4.90E-01
4.72E-01
4.48E-01
4.18E-01
3.64E-01
358
5.10E-01
5.09E-01
4.74E-01
4.54E-01
3.98E-01
359
4.96E-01
4.91E-01
4.60E-01
4.26E-01
3.83E-01
360
4.74E-01
4.59E-01
4.66E-01
4.62E-01
4.64E-01
361
5.13E-01
5.04E-01
5.17E-01
5.11E-01
5.19E-01
Biased Statistics
Average Biased
4.88E-01
4.60E-01
4.56E-01
4.27E-01
3.79E-01
Std Dev Biased
1.86E-02
1.69E-02
1.71E-02
1.31E-02
1.38E-02
Ps90%/90% (+KTL) Biased
5.39E-01
5.07E-01
5.03E-01
4.63E-01
4.17E-01
Ps90%/90% (-KTL) Biased
4.36E-01
4.14E-01
4.09E-01
3.91E-01
3.41E-01
Un-Biased Statistics
Average Un-Biased
5.01E-01
4.90E-01
4.62E-01
4.36E-01
3.85E-01
Std Dev Un-Biased
9.83E-03
1.46E-02
1.37E-02
1.60E-02
1.52E-02
Ps90%/90% (+KTL) Un-Biased
5.28E-01
5.30E-01
5.00E-01
4.79E-01
4.27E-01
Ps90%/90% (-KTL) Un-Biased
4.74E-01
4.50E-01
4.25E-01
3.92E-01
3.44E-01
Specification MIN
2.00E-01
1.20E-01
1.10E-01
7.00E-02
1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
90
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
5.00E-01
Positive Slew Rate 4 @ +/-15V (V/us)
4.50E-01
4.00E-01
3.50E-01
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.42. Plot of Positive Slew Rate 4 @ +/-15V (V/us) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
91
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.42. Raw data for Positive Slew Rate 4 @ +/-15V (V/us) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Slew Rate 4 @ +/-15V (V/us)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
4.49E-01
4.33E-01
4.19E-01
3.93E-01
3.47E-01
351
4.38E-01
4.34E-01
4.17E-01
3.87E-01
3.41E-01
352
4.84E-01
4.69E-01
4.48E-01
4.18E-01
3.77E-01
353
4.85E-01
4.75E-01
4.59E-01
4.33E-01
3.82E-01
354
4.94E-01
4.68E-01
4.64E-01
4.30E-01
3.80E-01
355
4.88E-01
4.76E-01
4.61E-01
4.36E-01
3.79E-01
356
4.80E-01
4.57E-01
4.44E-01
4.10E-01
3.57E-01
357
4.60E-01
4.45E-01
4.22E-01
4.01E-01
3.45E-01
358
4.39E-01
4.32E-01
4.10E-01
3.82E-01
3.39E-01
359
4.47E-01
4.23E-01
4.13E-01
3.78E-01
3.35E-01
360
4.53E-01
4.40E-01
4.45E-01
4.39E-01
4.42E-01
361
4.41E-01
4.41E-01
4.37E-01
4.35E-01
4.37E-01
Biased Statistics
Average Biased
4.70E-01
4.56E-01
4.41E-01
4.12E-01
3.65E-01
Std Dev Biased
2.48E-02
2.05E-02
2.21E-02
2.11E-02
1.97E-02
Ps90%/90% (+KTL) Biased
5.38E-01
5.12E-01
5.02E-01
4.70E-01
4.20E-01
Ps90%/90% (-KTL) Biased
4.02E-01
3.99E-01
3.81E-01
3.54E-01
3.11E-01
Un-Biased Statistics
Average Un-Biased
4.63E-01
4.47E-01
4.30E-01
4.01E-01
3.51E-01
Std Dev Un-Biased
2.09E-02
2.09E-02
2.19E-02
2.34E-02
1.77E-02
Ps90%/90% (+KTL) Un-Biased
5.20E-01
5.04E-01
4.90E-01
4.66E-01
4.00E-01
Ps90%/90% (-KTL) Un-Biased
4.05E-01
3.89E-01
3.70E-01
3.37E-01
3.02E-01
Specification MIN
2.00E-01
1.20E-01
1.10E-01
7.00E-02
1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
92
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Slew Rate 1 @ +/-15V (V/us)
0.00E+00
-1.00E-01
-2.00E-01
-3.00E-01
-4.00E-01
-5.00E-01
-6.00E-01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.43. Plot of Negative Slew Rate 1 @ +/-15V (V/us) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
93
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.43. Raw data for Negative Slew Rate 1 @ +/-15V (V/us) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Slew Rate 1 @ +/-15V (V/us)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -5.54E-01 -5.11E-01 -4.96E-01 -4.72E-01 -4.11E-01
351 -5.28E-01 -5.09E-01 -4.86E-01 -4.60E-01 -3.93E-01
352 -5.66E-01 -5.53E-01 -5.29E-01 -4.97E-01 -4.45E-01
353 -5.84E-01 -5.52E-01 -5.49E-01 -4.99E-01 -4.52E-01
354 -5.93E-01 -5.52E-01 -5.37E-01 -5.33E-01 -4.57E-01
355 -5.74E-01 -5.67E-01 -5.38E-01 -5.10E-01 -4.49E-01
356 -5.75E-01 -5.41E-01 -5.12E-01 -4.88E-01 -4.25E-01
357 -5.26E-01 -5.31E-01 -4.96E-01 -4.73E-01 -4.21E-01
358 -5.14E-01 -5.03E-01 -4.74E-01 -4.49E-01 -3.96E-01
359 -5.19E-01 -5.00E-01 -4.93E-01 -4.46E-01 -3.93E-01
360 -5.43E-01 -5.12E-01 -5.05E-01 -5.25E-01 -5.16E-01
361 -5.18E-01 -5.02E-01 -5.13E-01 -5.05E-01 -5.10E-01
Biased Statistics
Average Biased
-5.65E-01 -5.35E-01 -5.19E-01 -4.92E-01 -4.32E-01
Std Dev Biased
2.57E-02
2.32E-02
2.71E-02
2.82E-02
2.81E-02
Ps90%/90% (+KTL) Biased
-4.95E-01 -4.72E-01 -4.45E-01 -4.15E-01 -3.55E-01
Ps90%/90% (-KTL) Biased
-6.35E-01 -5.99E-01 -5.94E-01 -5.69E-01 -5.09E-01
Un-Biased Statistics
Average Un-Biased
-5.42E-01 -5.28E-01 -5.03E-01 -4.73E-01 -4.17E-01
Std Dev Un-Biased
3.03E-02
2.79E-02
2.40E-02
2.69E-02
2.30E-02
Ps90%/90% (+KTL) Un-Biased
-4.58E-01 -4.52E-01 -4.37E-01 -3.99E-01 -3.54E-01
Ps90%/90% (-KTL) Un-Biased
-6.25E-01 -6.05E-01 -5.68E-01 -5.47E-01 -4.80E-01
Specification MAX
-2.00E-01 -1.20E-01 -1.10E-01 -7.00E-02 -1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
94
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Slew Rate 2 @ +/-15V (V/us)
0.00E+00
-1.00E-01
-2.00E-01
-3.00E-01
-4.00E-01
-5.00E-01
-6.00E-01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.44. Plot of Negative Slew Rate 2 @ +/-15V (V/us) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
95
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.44. Raw data for Negative Slew Rate 2 @ +/-15V (V/us) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Slew Rate 2 @ +/-15V (V/us)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -5.03E-01 -4.74E-01 -4.61E-01 -4.41E-01 -3.81E-01
351 -4.98E-01 -4.91E-01 -4.55E-01 -4.32E-01 -3.83E-01
352 -4.92E-01 -4.80E-01 -4.58E-01 -4.39E-01 -3.96E-01
353 -5.33E-01 -5.24E-01 -5.06E-01 -4.75E-01 -4.09E-01
354 -5.12E-01 -4.93E-01 -4.80E-01 -4.45E-01 -3.95E-01
355 -5.59E-01 -5.22E-01 -4.97E-01 -4.83E-01 -4.23E-01
356 -5.29E-01 -5.17E-01 -4.80E-01 -4.44E-01 -4.04E-01
357 -5.06E-01 -4.98E-01 -4.64E-01 -4.33E-01 -3.75E-01
358 -5.57E-01 -5.19E-01 -4.95E-01 -4.70E-01 -4.19E-01
359 -5.25E-01 -4.92E-01 -4.81E-01 -4.50E-01 -3.98E-01
360 -4.97E-01 -4.86E-01 -4.81E-01 -4.88E-01 -4.83E-01
361 -5.54E-01 -5.42E-01 -5.27E-01 -5.40E-01 -5.28E-01
Biased Statistics
Average Biased
-5.08E-01 -4.92E-01 -4.72E-01 -4.46E-01 -3.93E-01
Std Dev Biased
1.60E-02
1.93E-02
2.14E-02
1.67E-02
1.13E-02
Ps90%/90% (+KTL) Biased
-4.64E-01 -4.39E-01 -4.13E-01 -4.01E-01 -3.62E-01
Ps90%/90% (-KTL) Biased
-5.51E-01 -5.45E-01 -5.31E-01 -4.92E-01 -4.24E-01
Un-Biased Statistics
Average Un-Biased
-5.35E-01 -5.10E-01 -4.83E-01 -4.56E-01 -4.04E-01
Std Dev Un-Biased
2.26E-02
1.36E-02
1.34E-02
2.02E-02
1.91E-02
Ps90%/90% (+KTL) Un-Biased
-4.73E-01 -4.72E-01 -4.47E-01 -4.01E-01 -3.51E-01
Ps90%/90% (-KTL) Un-Biased
-5.97E-01 -5.47E-01 -5.20E-01 -5.11E-01 -4.56E-01
Specification MAX
-2.00E-01 -1.20E-01 -1.10E-01 -7.00E-02 -1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
96
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Slew Rate 3 @ +/-15V (V/us)
0.00E+00
-1.00E-01
-2.00E-01
-3.00E-01
-4.00E-01
-5.00E-01
-6.00E-01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.45. Plot of Negative Slew Rate 3 @ +/-15V (V/us) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
97
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.45. Raw data for Negative Slew Rate 3 @ +/-15V (V/us) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Slew Rate 3 @ +/-15V (V/us)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -5.29E-01 -5.09E-01 -4.94E-01 -4.55E-01 -4.08E-01
351 -5.15E-01 -4.98E-01 -4.87E-01 -4.66E-01 -4.09E-01
352 -5.27E-01 -5.08E-01 -4.95E-01 -4.74E-01 -4.18E-01
353 -5.79E-01 -5.41E-01 -5.41E-01 -5.12E-01 -4.33E-01
354 -5.37E-01 -5.03E-01 -5.11E-01 -4.97E-01 -4.19E-01
355 -5.69E-01 -5.58E-01 -5.39E-01 -5.01E-01 -4.46E-01
356 -5.33E-01 -5.24E-01 -5.24E-01 -4.83E-01 -4.25E-01
357 -5.43E-01 -5.12E-01 -4.94E-01 -4.90E-01 -4.08E-01
358 -5.78E-01 -5.69E-01 -5.31E-01 -5.01E-01 -4.41E-01
359 -5.43E-01 -5.25E-01 -5.22E-01 -4.79E-01 -4.32E-01
360 -5.11E-01 -5.19E-01 -5.13E-01 -5.14E-01 -5.03E-01
361 -5.75E-01 -5.66E-01 -5.65E-01 -5.66E-01 -5.55E-01
Biased Statistics
Average Biased
-5.37E-01 -5.12E-01 -5.06E-01 -4.81E-01 -4.17E-01
Std Dev Biased
2.46E-02
1.69E-02
2.17E-02
2.33E-02
1.01E-02
Ps90%/90% (+KTL) Biased
-4.70E-01 -4.65E-01 -4.46E-01 -4.17E-01 -3.90E-01
Ps90%/90% (-KTL) Biased
-6.05E-01 -5.58E-01 -5.65E-01 -5.45E-01 -4.45E-01
Un-Biased Statistics
Average Un-Biased
-5.53E-01 -5.38E-01 -5.22E-01 -4.91E-01 -4.30E-01
Std Dev Un-Biased
1.92E-02
2.45E-02
1.70E-02
1.01E-02
1.49E-02
Ps90%/90% (+KTL) Un-Biased
-5.00E-01 -4.70E-01 -4.75E-01 -4.63E-01 -3.90E-01
Ps90%/90% (-KTL) Un-Biased
-6.06E-01 -6.05E-01 -5.69E-01 -5.19E-01 -4.71E-01
Specification MAX
-2.00E-01 -1.20E-01 -1.10E-01 -7.00E-02 -1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
98
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Negative Slew Rate 4 @ +/-15V (V/us)
0.00E+00
-1.00E-01
-2.00E-01
-3.00E-01
-4.00E-01
-5.00E-01
-6.00E-01
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.46. Plot of Negative Slew Rate 4 @ +/-15V (V/us) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
99
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.46. Raw data for Negative Slew Rate 4 @ +/-15V (V/us) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Slew Rate 4 @ +/-15V (V/us)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -5.11E-01 -4.85E-01 -4.67E-01 -4.45E-01 -3.80E-01
351 -4.90E-01 -4.89E-01 -4.56E-01 -4.34E-01 -3.79E-01
352 -5.41E-01 -5.27E-01 -4.89E-01 -4.77E-01 -4.23E-01
353 -5.39E-01 -5.20E-01 -4.94E-01 -4.66E-01 -4.21E-01
354 -5.73E-01 -5.13E-01 -4.96E-01 -4.76E-01 -4.20E-01
355 -5.39E-01 -5.38E-01 -5.07E-01 -4.78E-01 -4.28E-01
356 -5.25E-01 -5.20E-01 -4.84E-01 -4.51E-01 -4.01E-01
357 -5.12E-01 -4.94E-01 -4.77E-01 -4.45E-01 -3.85E-01
358 -4.95E-01 -4.92E-01 -4.55E-01 -4.26E-01 -3.65E-01
359 -4.89E-01 -4.75E-01 -4.67E-01 -4.26E-01 -3.70E-01
360 -5.03E-01 -4.91E-01 -4.82E-01 -4.86E-01 -4.82E-01
361 -5.07E-01 -4.89E-01 -4.70E-01 -4.94E-01 -4.85E-01
Biased Statistics
Average Biased
-5.31E-01 -5.07E-01 -4.80E-01 -4.60E-01 -4.05E-01
Std Dev Biased
3.17E-02
1.88E-02
1.79E-02
1.92E-02
2.29E-02
Ps90%/90% (+KTL) Biased
-4.44E-01 -4.55E-01 -4.31E-01 -4.07E-01 -3.42E-01
Ps90%/90% (-KTL) Biased
-6.18E-01 -5.58E-01 -5.29E-01 -5.12E-01 -4.68E-01
Un-Biased Statistics
Average Un-Biased
-5.12E-01 -5.04E-01 -4.78E-01 -4.45E-01 -3.90E-01
Std Dev Un-Biased
2.07E-02
2.50E-02
1.95E-02
2.15E-02
2.56E-02
Ps90%/90% (+KTL) Un-Biased
-4.55E-01 -4.35E-01 -4.24E-01 -3.86E-01 -3.20E-01
Ps90%/90% (-KTL) Un-Biased
-5.69E-01 -5.72E-01 -5.32E-01 -5.04E-01 -4.60E-01
Specification MAX
-2.00E-01 -1.20E-01 -1.10E-01 -7.00E-02 -1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
100
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Positive Supply Current @ +5V (A)
2.50E-03
2.00E-03
1.50E-03
1.00E-03
5.00E-04
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.47. Plot of Positive Supply Current @ +5V (A) versus total dose. The solid diamonds are the average of
the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
101
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.47. Raw data for Positive Supply Current @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Supply Current @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.31E-03
1.35E-03
1.29E-03
1.14E-03
9.29E-04
351
1.31E-03
1.35E-03
1.29E-03
1.15E-03
9.39E-04
352
1.35E-03
1.38E-03
1.32E-03
1.18E-03
9.73E-04
353
1.34E-03
1.35E-03
1.27E-03
1.14E-03
9.28E-04
354
1.32E-03
1.39E-03
1.28E-03
1.14E-03
9.32E-04
355
1.41E-03
1.47E-03
1.40E-03
1.25E-03
1.01E-03
356
1.31E-03
1.38E-03
1.31E-03
1.16E-03
9.19E-04
357
1.33E-03
1.38E-03
1.31E-03
1.17E-03
9.33E-04
358
1.32E-03
1.38E-03
1.31E-03
1.17E-03
9.40E-04
359
1.31E-03
1.38E-03
1.31E-03
1.17E-03
9.36E-04
360
1.30E-03
1.29E-03
1.30E-03
1.29E-03
1.30E-03
361
1.33E-03
1.32E-03
1.32E-03
1.32E-03
1.32E-03
Biased Statistics
Average Biased
1.33E-03
1.36E-03
1.29E-03
1.15E-03
9.40E-04
Std Dev Biased
1.64E-05
1.71E-05
1.85E-05
1.78E-05
1.88E-05
Ps90%/90% (+KTL) Biased
1.37E-03
1.41E-03
1.34E-03
1.20E-03
9.92E-04
Ps90%/90% (-KTL) Biased
1.28E-03
1.32E-03
1.24E-03
1.10E-03
8.89E-04
Un-Biased Statistics
Average Un-Biased
1.34E-03
1.40E-03
1.32E-03
1.18E-03
9.47E-04
Std Dev Un-Biased
4.11E-05
3.99E-05
3.94E-05
3.63E-05
3.40E-05
Ps90%/90% (+KTL) Un-Biased
1.45E-03
1.51E-03
1.43E-03
1.28E-03
1.04E-03
Ps90%/90% (-KTL) Un-Biased
1.22E-03
1.29E-03
1.22E-03
1.08E-03
8.54E-04
2.00E-03
Specification MAX
2.00E-03
2.00E-03
2.00E-03
2.00E-03
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
102
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Negative Supply Current @ +5V (A)
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
-2.00E-03
-2.50E-03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.48. Plot of Negative Supply Current @ +5V (A) versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
103
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.48. Raw data for Negative Supply Current @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Supply Current @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -1.29E-03 -1.32E-03 -1.27E-03 -1.12E-03 -9.02E-04
351 -1.29E-03 -1.32E-03 -1.26E-03 -1.12E-03 -9.14E-04
352 -1.33E-03 -1.36E-03 -1.30E-03 -1.16E-03 -9.53E-04
353 -1.32E-03 -1.33E-03 -1.26E-03 -1.11E-03 -8.98E-04
354 -1.30E-03 -1.36E-03 -1.26E-03 -1.12E-03 -9.07E-04
355 -1.39E-03 -1.45E-03 -1.38E-03 -1.23E-03 -9.82E-04
356 -1.29E-03 -1.36E-03 -1.28E-03 -1.13E-03 -8.90E-04
357 -1.30E-03 -1.36E-03 -1.29E-03 -1.15E-03 -9.09E-04
358 -1.30E-03 -1.36E-03 -1.28E-03 -1.15E-03 -9.19E-04
359 -1.29E-03 -1.36E-03 -1.29E-03 -1.14E-03 -9.09E-04
360 -1.28E-03 -1.27E-03 -1.27E-03 -1.27E-03 -1.27E-03
361 -1.31E-03 -1.29E-03 -1.30E-03 -1.30E-03 -1.30E-03
Biased Statistics
Average Biased
-1.31E-03 -1.34E-03 -1.27E-03 -1.13E-03 -9.15E-04
Std Dev Biased
1.86E-05
2.17E-05
1.77E-05
1.77E-05
2.22E-05
Ps90%/90% (+KTL) Biased
-1.25E-03 -1.28E-03 -1.22E-03 -1.08E-03 -8.54E-04
Ps90%/90% (-KTL) Biased
-1.36E-03 -1.40E-03 -1.32E-03 -1.17E-03 -9.76E-04
Un-Biased Statistics
Average Un-Biased
-1.32E-03 -1.38E-03 -1.30E-03 -1.16E-03 -9.22E-04
Std Dev Un-Biased
4.26E-05
4.01E-05
4.18E-05
3.79E-05
3.53E-05
Ps90%/90% (+KTL) Un-Biased
-1.20E-03 -1.27E-03 -1.19E-03 -1.06E-03 -8.25E-04
Ps90%/90% (-KTL) Un-Biased
-1.43E-03 -1.49E-03 -1.42E-03 -1.26E-03 -1.02E-03
Specification MIN
-2.00E-03 -2.00E-03 -2.00E-03 -2.00E-03 -2.00E-03
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
104
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-03
Offset Voltage 1 @ +5V (V)
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.49. Plot of Offset Voltage 1 @ +5V (V) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
105
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.49. Raw data for Offset Voltage 1 @ +5V (V) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Voltage 1 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -3.05E-05 -2.03E-05
1.41E-05
6.39E-05
1.68E-04
351
4.57E-05
5.20E-05
7.56E-05
1.20E-04
1.97E-04
352 -5.15E-05 -4.38E-05 -1.60E-05
2.87E-05
1.07E-04
353 -4.41E-05 -3.85E-05 -1.52E-05
1.03E-05
4.84E-05
354
4.07E-05 -4.46E-05
6.97E-05
1.04E-04
1.70E-04
355 -2.75E-05 -1.39E-05
1.29E-05
5.85E-05
1.62E-04
356 -6.70E-05 -5.46E-05 -3.25E-05
6.10E-06
9.22E-05
357 -3.61E-05 -2.31E-05
1.99E-06
4.52E-05
1.27E-04
358
2.07E-05
3.91E-05
7.44E-05
1.32E-04
2.63E-04
359 -4.74E-05 -3.22E-05 -3.20E-06
5.87E-05
1.74E-04
360 -1.97E-05 -1.93E-05 -1.97E-05 -1.93E-05 -1.88E-05
361
2.82E-05
2.64E-05
2.63E-05
2.72E-05
2.67E-05
Biased Statistics
Average Biased
-7.93E-06 -1.90E-05
2.57E-05
6.53E-05
1.38E-04
Std Dev Biased
4.73E-05
4.09E-05
4.46E-05
4.70E-05
5.98E-05
Ps90%/90% (+KTL) Biased
1.22E-04
9.31E-05
1.48E-04
1.94E-04
3.02E-04
Ps90%/90% (-KTL) Biased
-1.38E-04 -1.31E-04 -9.68E-05 -6.35E-05 -2.62E-05
Un-Biased Statistics
Average Un-Biased
-3.15E-05 -1.70E-05
1.07E-05
6.01E-05
1.64E-04
Std Dev Un-Biased
3.27E-05
3.48E-05
3.94E-05
4.55E-05
6.41E-05
Ps90%/90% (+KTL) Un-Biased
5.82E-05
7.84E-05
1.19E-04
1.85E-04
3.39E-04
Ps90%/90% (-KTL) Un-Biased
-1.21E-04 -1.12E-04 -9.73E-05 -6.48E-05 -1.22E-05
Specification MIN
-4.50E-04 -6.00E-04 -7.50E-04 -9.00E-04 -9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
4.50E-04
6.00E-04
7.50E-04
9.00E-04
9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
106
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-03
Offset Voltage 2 @ +5V (V)
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.50. Plot of Offset Voltage 2 @ +5V (V) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
107
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.50. Raw data for Offset Voltage 2 @ +5V (V) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Voltage 2 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -8.99E-05 -7.71E-05 -5.80E-05 -1.85E-05
5.46E-05
351
8.74E-05
9.78E-05
1.24E-04
1.71E-04
2.53E-04
352
1.01E-05
1.60E-05
4.12E-05
7.65E-05
1.44E-04
353 -5.62E-05 -4.97E-05 -4.05E-05 -1.74E-05
1.01E-05
354 -1.15E-05
1.68E-05
2.47E-05
6.21E-05
1.42E-04
355
5.30E-05
3.74E-05
5.63E-05
1.07E-04
1.94E-04
356 -1.79E-05 -3.93E-06
1.62E-05
5.67E-05
1.43E-04
357 -4.21E-05 -2.63E-05 -3.81E-06
3.51E-05
1.23E-04
358 -1.33E-04 -1.26E-04 -1.20E-04 -9.89E-05 -5.96E-05
359 -4.22E-05 -2.86E-05 -5.13E-06
3.78E-05
1.31E-04
360 -4.40E-05 -4.20E-05 -4.18E-05 -4.24E-05 -4.24E-05
361 -8.68E-05 -8.43E-05 -8.45E-05 -8.42E-05 -8.52E-05
Biased Statistics
Average Biased
-1.20E-05
7.82E-07
1.82E-05
5.47E-05
1.21E-04
Std Dev Biased
6.78E-05
6.80E-05
7.23E-05
7.85E-05
9.35E-05
Ps90%/90% (+KTL) Biased
1.74E-04
1.87E-04
2.17E-04
2.70E-04
3.77E-04
Ps90%/90% (-KTL) Biased
-1.98E-04 -1.86E-04 -1.80E-04 -1.61E-04 -1.36E-04
Un-Biased Statistics
Average Un-Biased
-3.64E-05 -2.96E-05 -1.12E-05
2.74E-05
1.06E-04
Std Dev Un-Biased
6.65E-05
6.03E-05
6.55E-05
7.62E-05
9.68E-05
Ps90%/90% (+KTL) Un-Biased
1.46E-04
1.36E-04
1.68E-04
2.36E-04
3.72E-04
Ps90%/90% (-KTL) Un-Biased
-2.19E-04 -1.95E-04 -1.91E-04 -1.82E-04 -1.59E-04
Specification MIN
-4.50E-04 -6.00E-04 -7.50E-04 -9.00E-04 -9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
4.50E-04
6.00E-04
7.50E-04
9.00E-04
9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
108
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-03
Offset Voltage 3 @ +5V (V)
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.51. Plot of Offset Voltage 3 @ +5V (V) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
109
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.51. Raw data for Offset Voltage 3 @ +5V (V) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Voltage 3 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
6.92E-05
8.38E-05
1.13E-04
1.65E-04
2.60E-04
351 -2.81E-05 -9.36E-06
1.79E-05
6.04E-05
1.46E-04
352 -4.35E-05 -3.41E-05 -1.43E-05
1.88E-05
5.69E-05
353
1.86E-05
2.57E-05
4.00E-05
5.79E-05
8.14E-05
354
5.01E-05 -3.39E-05
8.13E-05
1.14E-04
1.71E-04
355
2.79E-05
3.75E-05
5.90E-05
1.04E-04
2.06E-04
356
2.76E-05
4.22E-05
7.15E-05
1.26E-04
2.44E-04
357 -3.82E-05 -2.23E-05
4.89E-06
4.88E-05
1.36E-04
358 -7.90E-05 -7.55E-05 -5.63E-05 -2.11E-05
5.66E-05
359
1.31E-05
3.29E-05
5.61E-05
1.00E-04
2.02E-04
360
4.09E-05
3.99E-05
4.06E-05
4.05E-05
4.05E-05
361
1.73E-05
1.74E-05
1.80E-05
1.79E-05
1.74E-05
Biased Statistics
Average Biased
1.33E-05
6.43E-06
4.76E-05
8.33E-05
1.43E-04
Std Dev Biased
4.86E-05
4.97E-05
5.04E-05
5.71E-05
8.00E-05
Ps90%/90% (+KTL) Biased
1.47E-04
1.43E-04
1.86E-04
2.40E-04
3.62E-04
Ps90%/90% (-KTL) Biased
-1.20E-04 -1.30E-04 -9.06E-05 -7.31E-05 -7.63E-05
Un-Biased Statistics
Average Un-Biased
-9.72E-06
2.96E-06
2.70E-05
7.15E-05
1.69E-04
Std Dev Un-Biased
4.73E-05
5.10E-05
5.31E-05
5.89E-05
7.40E-05
Ps90%/90% (+KTL) Un-Biased
1.20E-04
1.43E-04
1.73E-04
2.33E-04
3.72E-04
Ps90%/90% (-KTL) Un-Biased
-1.39E-04 -1.37E-04 -1.19E-04 -9.01E-05 -3.38E-05
Specification MIN
-4.50E-04 -6.00E-04 -7.50E-04 -9.00E-04 -9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
4.50E-04
6.00E-04
7.50E-04
9.00E-04
9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
110
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-03
Offset Voltage 4 @ +5V (V)
8.00E-04
6.00E-04
4.00E-04
2.00E-04
0.00E+00
-2.00E-04
-4.00E-04
-6.00E-04
-8.00E-04
-1.00E-03
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.52. Plot of Offset Voltage 4 @ +5V (V) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
111
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.52. Raw data for Offset Voltage 4 @ +5V (V) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Voltage 4 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -3.41E-05 -1.87E-05
1.02E-05
6.19E-05
1.46E-04
351
1.67E-05
3.23E-05
5.37E-05
9.97E-05
1.81E-04
352 -6.54E-05 -4.94E-05 -3.12E-05
8.15E-06
8.47E-05
353 -5.74E-05 -4.82E-05 -3.69E-05 -9.84E-06
3.16E-05
354 -1.12E-04 -4.92E-05 -8.57E-05 -5.52E-05 -9.84E-06
355 -3.75E-05 -2.80E-05 -7.67E-06
2.98E-05
1.17E-04
356 -1.44E-04 -1.31E-04 -9.87E-05 -4.65E-05
6.68E-05
357 -3.92E-05 -2.75E-05
4.28E-06
6.03E-05
1.74E-04
358
9.35E-06
2.13E-05
4.80E-05
9.89E-05
2.19E-04
359 -1.99E-06
1.03E-05
4.44E-05
1.01E-04
2.09E-04
360
9.71E-06
9.11E-06
9.11E-06
8.39E-06
9.24E-06
361
9.96E-06
1.12E-05
1.10E-05
1.12E-05
1.23E-05
Biased Statistics
Average Biased
-5.04E-05 -2.66E-05 -1.80E-05
2.09E-05
8.67E-05
Std Dev Biased
4.70E-05
3.55E-05
5.25E-05
6.08E-05
7.86E-05
Ps90%/90% (+KTL) Biased
7.84E-05
7.06E-05
1.26E-04
1.88E-04
3.02E-04
Ps90%/90% (-KTL) Biased
-1.79E-04 -1.24E-04 -1.62E-04 -1.46E-04 -1.29E-04
Un-Biased Statistics
Average Un-Biased
-4.27E-05 -3.09E-05 -1.95E-06
4.86E-05
1.57E-04
Std Dev Un-Biased
6.06E-05
6.00E-05
5.93E-05
6.08E-05
6.44E-05
Ps90%/90% (+KTL) Un-Biased
1.23E-04
1.34E-04
1.61E-04
2.15E-04
3.34E-04
Ps90%/90% (-KTL) Un-Biased
-2.09E-04 -1.95E-04 -1.65E-04 -1.18E-04 -1.94E-05
Specification MIN
-4.50E-04 -6.00E-04 -7.50E-04 -9.00E-04 -9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
4.50E-04
6.00E-04
7.50E-04
9.00E-04
9.00E-04
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
112
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
2.50E-08
Offset Current 1 @ +5V (A)
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
-2.50E-08
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.53. Plot of Offset Current 1 @ +5V (A) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
113
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.53. Raw data for Offset Current 1 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Current 1 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -1.10E-11 -6.10E-11 -4.50E-11 -9.50E-11 -1.09E-10
351 -2.10E-11
5.00E-11
1.86E-10
3.71E-10
9.06E-10
352 -1.30E-11 -1.11E-10
8.00E-12
2.50E-10
4.11E-10
353
6.60E-11
1.33E-10 -1.00E-11
2.09E-10
5.01E-10
354 -1.07E-10 -9.10E-11 -2.73E-10 -4.44E-10 -4.80E-10
355
7.70E-11
9.70E-11
1.90E-11
1.40E-10 -6.70E-11
356
2.00E-12
1.18E-10 -4.10E-11
1.40E-10
2.44E-10
357 -1.20E-11 -8.00E-11 -1.44E-10
9.10E-11
5.51E-10
358 -8.80E-11 -4.70E-11
4.70E-11
1.28E-10
1.08E-10
359
2.30E-11 -2.40E-11
2.50E-11
2.14E-10
4.26E-10
360 -1.43E-10 -1.38E-10 -1.48E-10 -1.32E-10 -1.25E-10
361 -2.10E-11 -1.30E-11 -3.30E-11 -2.80E-11 -1.30E-11
Biased Statistics
Average Biased
-1.72E-11 -1.60E-11 -2.68E-11
5.82E-11
2.46E-10
Std Dev Biased
6.14E-11
1.04E-10
1.64E-10
3.29E-10
5.43E-10
Ps90%/90% (+KTL) Biased
1.51E-10
2.69E-10
4.23E-10
9.60E-10
1.74E-09
Ps90%/90% (-KTL) Biased
-1.85E-10 -3.01E-10 -4.77E-10 -8.44E-10 -1.24E-09
Un-Biased Statistics
Average Un-Biased
4.00E-13
1.28E-11 -1.88E-11
1.43E-10
2.52E-10
Std Dev Un-Biased
5.99E-11
8.90E-11
7.72E-11
4.47E-11
2.46E-10
Ps90%/90% (+KTL) Un-Biased
1.65E-10
2.57E-10
1.93E-10
2.65E-10
9.27E-10
Ps90%/90% (-KTL) Un-Biased
-1.64E-10 -2.31E-10 -2.31E-10
2.01E-11 -4.22E-10
Specification MIN
-1.00E-08 -1.00E-08 -1.50E-08 -2.00E-08 -2.00E-08
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
1.00E-08
1.00E-08
1.50E-08
2.00E-08
2.00E-08
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
114
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
2.50E-08
Offset Current 2 @ +5V (A)
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
-2.50E-08
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.54. Plot of Offset Current 2 @ +5V (A) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
115
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.54. Raw data for Offset Current 2 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Current 2 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -3.30E-11 -1.28E-10 -1.67E-10 -2.85E-10 -1.55E-10
351 -4.20E-11 -3.90E-11
9.30E-11
6.10E-11
3.00E-10
352 -3.90E-11
2.90E-11
7.60E-11
1.18E-10
2.61E-10
353 -2.40E-11 -1.42E-10 -1.71E-10 -3.40E-10 -4.56E-10
354 -2.30E-11
3.70E-11 -1.44E-10 -3.40E-11
1.76E-10
355
1.60E-11
2.00E-12
9.20E-11
2.70E-11
2.56E-10
356
4.30E-11 -3.00E-12
2.19E-10
1.63E-10
1.23E-10
357 -8.00E-11 -3.70E-11
1.20E-11
2.97E-10
8.18E-10
358
1.74E-10
2.34E-10
3.37E-10
4.84E-10
1.03E-09
359
4.00E-11
4.20E-11
4.10E-11
1.51E-10
4.35E-10
360 -1.01E-10 -1.09E-10 -1.21E-10 -1.14E-10 -9.90E-11
361 -8.60E-11 -1.03E-10 -6.50E-11 -9.00E-11 -9.30E-11
Biased Statistics
Average Biased
-3.22E-11 -4.86E-11 -6.26E-11 -9.60E-11
2.52E-11
Std Dev Biased
8.58E-12
8.44E-11
1.35E-10
2.06E-10
3.23E-10
Ps90%/90% (+KTL) Biased
-8.66E-12
1.83E-10
3.07E-10
4.69E-10
9.11E-10
Ps90%/90% (-KTL) Biased
-5.57E-11 -2.80E-10 -4.32E-10 -6.61E-10 -8.61E-10
Un-Biased Statistics
Average Un-Biased
3.86E-11
4.76E-11
1.40E-10
2.24E-10
5.32E-10
Std Dev Un-Biased
9.07E-11
1.08E-10
1.36E-10
1.74E-10
3.82E-10
Ps90%/90% (+KTL) Un-Biased
2.87E-10
3.43E-10
5.12E-10
7.01E-10
1.58E-09
Ps90%/90% (-KTL) Un-Biased
-2.10E-10 -2.48E-10 -2.32E-10 -2.52E-10 -5.14E-10
Specification MIN
-1.00E-08 -1.00E-08 -1.50E-08 -2.00E-08 -2.00E-08
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
1.00E-08
1.00E-08
1.50E-08
2.00E-08
2.00E-08
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
116
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
2.50E-08
Offset Current 3 @ +5V (A)
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
-2.50E-08
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.55. Plot of Offset Current 3 @ +5V (A) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
117
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.55. Raw data for Offset Current 3 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Current 3 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -7.00E-12 -5.10E-11
1.14E-10 -8.30E-11
4.20E-11
351
1.70E-11 -1.40E-10 -1.79E-10 -1.90E-10
1.37E-10
352
5.30E-11
6.90E-11
7.40E-11 -5.00E-11
2.91E-10
353 -6.80E-11 -9.20E-11 -1.03E-10 -2.22E-10 -3.21E-10
354 -1.60E-11
7.80E-11 -2.20E-11
9.00E-12
4.09E-10
355
8.00E-12
2.00E-12
3.50E-11
4.60E-11 -4.20E-11
356 -3.20E-11 -4.00E-11 -1.45E-10 -3.67E-10 -4.20E-10
357 -1.20E-11 -9.30E-11 -1.36E-10
1.37E-10
6.36E-10
358 -4.60E-11
2.90E-11
1.45E-10
2.31E-10
6.91E-10
359 -1.70E-10 -2.87E-10 -1.90E-10 -2.11E-10 -1.51E-10
360 -5.80E-11 -7.30E-11 -5.00E-11 -5.60E-11 -8.00E-11
361 -1.30E-11 -4.70E-11 -2.20E-11 -2.00E-11 -5.40E-11
Biased Statistics
Average Biased
-4.20E-12 -2.72E-11 -2.32E-11 -1.07E-10
1.12E-10
Std Dev Biased
4.45E-11
9.72E-11
1.21E-10
9.67E-11
2.80E-10
Ps90%/90% (+KTL) Biased
1.18E-10
2.39E-10
3.10E-10
1.58E-10
8.79E-10
Ps90%/90% (-KTL) Biased
-1.26E-10 -2.94E-10 -3.56E-10 -3.72E-10 -6.56E-10
Un-Biased Statistics
Average Un-Biased
-5.04E-11 -7.78E-11 -5.82E-11 -3.28E-11
1.43E-10
Std Dev Un-Biased
6.99E-11
1.26E-10
1.42E-10
2.49E-10
4.95E-10
Ps90%/90% (+KTL) Un-Biased
1.41E-10
2.67E-10
3.32E-10
6.50E-10
1.50E-09
Ps90%/90% (-KTL) Un-Biased
-2.42E-10 -4.22E-10 -4.48E-10 -7.16E-10 -1.22E-09
Specification MIN
-1.00E-08 -1.00E-08 -1.50E-08 -2.00E-08 -2.00E-08
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
1.00E-08
1.00E-08
1.50E-08
2.00E-08
2.00E-08
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
118
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
2.50E-08
Offset Current 4 @ +5V (A)
2.00E-08
1.50E-08
1.00E-08
5.00E-09
0.00E+00
-5.00E-09
-1.00E-08
-1.50E-08
-2.00E-08
-2.50E-08
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.56. Plot of Offset Current 4 @ +5V (A) versus total dose. The solid diamonds are the average of the
measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of
the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or
dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under
electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
119
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.56. Raw data for Offset Current 4 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Offset Current 4 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 -4.10E-11 -1.45E-10 -4.30E-11
1.01E-10
6.97E-10
351 -1.05E-10 -1.46E-10 -2.80E-11
2.80E-11
4.89E-10
352 -3.00E-11
3.00E-12
4.80E-11 -1.35E-10 -1.13E-10
353
6.80E-11
9.00E-11
3.60E-11
1.14E-10
9.18E-10
354 -7.60E-11 -5.10E-11 -3.56E-10 -4.10E-10
1.14E-10
355
4.00E-11
7.00E-12 -6.90E-11
2.40E-11 -7.70E-11
356 0.00E+00 -7.70E-11 -1.96E-10 -1.93E-10 -6.40E-11
357 -1.35E-10 -1.91E-10 -3.21E-10 -2.46E-10
4.00E-11
358 -1.90E-11 -2.40E-11
1.40E-11
1.45E-10
4.87E-10
359 -2.60E-11 -1.27E-10 -1.58E-10
5.70E-11
6.51E-10
360 -6.00E-12 -8.00E-12
8.00E-12
9.00E-12
1.10E-11
361
1.00E-12 0.00E+00 -1.70E-11 -2.20E-11 -2.70E-11
Biased Statistics
Average Biased
-3.68E-11 -4.98E-11 -6.86E-11 -6.04E-11
4.21E-10
Std Dev Biased
6.56E-11
1.01E-10
1.65E-10
2.19E-10
4.20E-10
Ps90%/90% (+KTL) Biased
1.43E-10
2.27E-10
3.85E-10
5.40E-10
1.57E-09
Ps90%/90% (-KTL) Biased
-2.17E-10 -3.26E-10 -5.22E-10 -6.61E-10 -7.32E-10
Un-Biased Statistics
Average Un-Biased
-2.80E-11 -8.24E-11 -1.46E-10 -4.26E-11
2.07E-10
Std Dev Un-Biased
6.51E-11
7.94E-11
1.27E-10
1.68E-10
3.38E-10
Ps90%/90% (+KTL) Un-Biased
1.50E-10
1.35E-10
2.03E-10
4.19E-10
1.13E-09
Ps90%/90% (-KTL) Un-Biased
-2.06E-10 -3.00E-10 -4.95E-10 -5.05E-10 -7.20E-10
Specification MIN
-1.00E-08 -1.00E-08 -1.50E-08 -2.00E-08 -2.00E-08
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
1.00E-08
1.00E-08
1.50E-08
2.00E-08
2.00E-08
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
120
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 1 @ +5V (A)
2.50E-07
2.00E-07
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.57. Plot of Positive Bias Current 1 @ +5V (A) versus total dose. The solid diamonds are the average of
the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
121
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.57. Raw data for Positive Bias Current 1 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Bias Current 1 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.33E-08
1.77E-08
2.64E-08
4.06E-08
6.57E-08
351
1.32E-08
1.80E-08
2.65E-08
4.01E-08
6.42E-08
352
1.35E-08
1.80E-08
2.64E-08
4.05E-08
6.48E-08
353
1.24E-08
1.70E-08
2.58E-08
3.97E-08
6.42E-08
354
1.29E-08
1.80E-08
2.69E-08
4.17E-08
6.83E-08
355
1.31E-08
1.77E-08
2.62E-08
3.94E-08
6.32E-08
356
1.25E-08
1.70E-08
2.56E-08
3.85E-08
6.12E-08
357
1.31E-08
1.74E-08
2.57E-08
3.83E-08
6.07E-08
358
1.35E-08
1.80E-08
2.62E-08
3.88E-08
6.11E-08
359
1.28E-08
1.71E-08
2.50E-08
3.74E-08
5.94E-08
360
1.35E-08
1.35E-08
1.34E-08
1.34E-08
1.34E-08
361
1.38E-08
1.37E-08
1.37E-08
1.37E-08
1.37E-08
Biased Statistics
Average Biased
1.31E-08
1.77E-08
2.64E-08
4.05E-08
6.54E-08
Std Dev Biased
4.27E-10
4.22E-10
4.13E-10
7.65E-10
1.72E-09
Ps90%/90% (+KTL) Biased
1.42E-08
1.89E-08
2.75E-08
4.26E-08
7.01E-08
Ps90%/90% (-KTL) Biased
1.19E-08
1.66E-08
2.53E-08
3.84E-08
6.07E-08
Un-Biased Statistics
Average Un-Biased
1.30E-08
1.74E-08
2.57E-08
3.85E-08
6.11E-08
Std Dev Un-Biased
3.71E-10
3.99E-10
5.16E-10
7.20E-10
1.38E-09
Ps90%/90% (+KTL) Un-Biased
1.40E-08
1.85E-08
2.72E-08
4.05E-08
6.49E-08
Ps90%/90% (-KTL) Un-Biased
1.20E-08
1.63E-08
2.43E-08
3.65E-08
5.74E-08
Specification MIN
-5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08
1.00E-07
1.25E-07
2.00E-07
2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
122
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 2 @ +5V (A)
2.50E-07
2.00E-07
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.58. Plot of Positive Bias Current 2 @ +5V (A) versus total dose. The solid diamonds are the average of
the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
123
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.58. Raw data for Positive Bias Current 2 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Bias Current 2 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.27E-08
1.69E-08
2.52E-08
3.88E-08
6.24E-08
351
1.23E-08
1.65E-08
2.43E-08
3.71E-08
5.95E-08
352
1.32E-08
1.73E-08
2.54E-08
3.87E-08
6.15E-08
353
1.18E-08
1.64E-08
2.51E-08
3.93E-08
6.37E-08
354
1.27E-08
1.74E-08
2.59E-08
3.99E-08
6.54E-08
355
1.26E-08
1.70E-08
2.50E-08
3.74E-08
5.98E-08
356
1.22E-08
1.66E-08
2.45E-08
3.70E-08
5.87E-08
357
1.24E-08
1.65E-08
2.41E-08
3.59E-08
5.68E-08
358
1.22E-08
1.65E-08
2.43E-08
3.65E-08
5.85E-08
359
1.25E-08
1.66E-08
2.43E-08
3.65E-08
5.79E-08
360
1.34E-08
1.34E-08
1.33E-08
1.34E-08
1.33E-08
361
1.20E-08
1.20E-08
1.20E-08
1.20E-08
1.20E-08
Biased Statistics
Average Biased
1.25E-08
1.69E-08
2.52E-08
3.87E-08
6.25E-08
Std Dev Biased
5.20E-10
4.62E-10
5.91E-10
1.06E-09
2.23E-09
Ps90%/90% (+KTL) Biased
1.40E-08
1.82E-08
2.68E-08
4.16E-08
6.86E-08
Ps90%/90% (-KTL) Biased
1.11E-08
1.56E-08
2.36E-08
3.58E-08
5.64E-08
Un-Biased Statistics
Average Un-Biased
1.24E-08
1.66E-08
2.44E-08
3.66E-08
5.83E-08
Std Dev Un-Biased
1.96E-10
2.23E-10
3.29E-10
5.64E-10
1.10E-09
Ps90%/90% (+KTL) Un-Biased
1.29E-08
1.72E-08
2.53E-08
3.82E-08
6.13E-08
Ps90%/90% (-KTL) Un-Biased
1.19E-08
1.60E-08
2.35E-08
3.51E-08
5.53E-08
Specification MIN
-5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08
1.00E-07
1.25E-07
2.00E-07
2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
124
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 3 @ +5V (A)
2.50E-07
2.00E-07
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.59. Plot of Positive Bias Current 3 @ +5V (A) versus total dose. The solid diamonds are the average of
the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
125
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.59. Raw data for Positive Bias Current 3 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Bias Current 3 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.32E-08
1.73E-08
2.57E-08
3.96E-08
6.36E-08
351
1.35E-08
1.80E-08
2.63E-08
4.01E-08
6.40E-08
352
1.31E-08
1.71E-08
2.51E-08
3.85E-08
6.13E-08
353
1.23E-08
1.70E-08
2.59E-08
4.05E-08
6.58E-08
354
1.25E-08
1.72E-08
2.54E-08
3.92E-08
6.43E-08
355
1.31E-08
1.75E-08
2.56E-08
3.83E-08
6.12E-08
356
1.32E-08
1.80E-08
2.66E-08
4.02E-08
6.35E-08
357
1.28E-08
1.71E-08
2.48E-08
3.69E-08
5.80E-08
358
1.27E-08
1.70E-08
2.51E-08
3.76E-08
6.01E-08
359
1.37E-08
1.81E-08
2.63E-08
3.93E-08
6.22E-08
360
1.41E-08
1.39E-08
1.40E-08
1.40E-08
1.40E-08
361
1.25E-08
1.24E-08
1.24E-08
1.24E-08
1.25E-08
Biased Statistics
Average Biased
1.29E-08
1.73E-08
2.57E-08
3.95E-08
6.38E-08
Std Dev Biased
4.74E-10
4.14E-10
4.65E-10
7.67E-10
1.62E-09
Ps90%/90% (+KTL) Biased
1.42E-08
1.85E-08
2.70E-08
4.17E-08
6.83E-08
Ps90%/90% (-KTL) Biased
1.16E-08
1.62E-08
2.44E-08
3.74E-08
5.94E-08
Un-Biased Statistics
Average Un-Biased
1.31E-08
1.75E-08
2.57E-08
3.85E-08
6.10E-08
Std Dev Un-Biased
3.65E-10
4.96E-10
7.67E-10
1.34E-09
2.08E-09
Ps90%/90% (+KTL) Un-Biased
1.41E-08
1.89E-08
2.78E-08
4.21E-08
6.67E-08
Ps90%/90% (-KTL) Un-Biased
1.21E-08
1.62E-08
2.36E-08
3.48E-08
5.53E-08
Specification MIN
-5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08
1.00E-07
1.25E-07
2.00E-07
2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
126
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Positive Bias Current 4 @ +5V (A)
2.50E-07
2.00E-07
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.60. Plot of Positive Bias Current 4 @ +5V (A) versus total dose. The solid diamonds are the average of
the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
127
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.60. Raw data for Positive Bias Current 4 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Bias Current 4 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.28E-08
1.71E-08
2.53E-08
3.88E-08
6.23E-08
351
1.22E-08
1.66E-08
2.45E-08
3.74E-08
5.95E-08
352
1.22E-08
1.64E-08
2.42E-08
3.75E-08
6.03E-08
353
1.20E-08
1.66E-08
2.51E-08
3.88E-08
6.25E-08
354
1.25E-08
1.65E-08
2.59E-08
3.99E-08
6.48E-08
355
1.27E-08
1.72E-08
2.56E-08
3.82E-08
6.09E-08
356
1.27E-08
1.73E-08
2.59E-08
3.89E-08
6.12E-08
357
1.33E-08
1.78E-08
2.62E-08
3.87E-08
6.08E-08
358
1.24E-08
1.65E-08
2.43E-08
3.60E-08
5.67E-08
359
1.25E-08
1.66E-08
2.43E-08
3.63E-08
5.71E-08
360
1.30E-08
1.29E-08
1.30E-08
1.29E-08
1.29E-08
361
1.26E-08
1.26E-08
1.26E-08
1.26E-08
1.26E-08
Biased Statistics
Average Biased
1.24E-08
1.66E-08
2.50E-08
3.85E-08
6.19E-08
Std Dev Biased
3.07E-10
2.66E-10
6.76E-10
1.06E-09
2.08E-09
Ps90%/90% (+KTL) Biased
1.32E-08
1.74E-08
2.69E-08
4.14E-08
6.76E-08
Ps90%/90% (-KTL) Biased
1.15E-08
1.59E-08
2.32E-08
3.56E-08
5.62E-08
Un-Biased Statistics
Average Un-Biased
1.27E-08
1.71E-08
2.52E-08
3.76E-08
5.93E-08
Std Dev Un-Biased
3.58E-10
5.13E-10
9.06E-10
1.39E-09
2.26E-09
Ps90%/90% (+KTL) Un-Biased
1.37E-08
1.85E-08
2.77E-08
4.14E-08
6.55E-08
Ps90%/90% (-KTL) Un-Biased
1.17E-08
1.57E-08
2.28E-08
3.38E-08
5.31E-08
Specification MIN
-5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08
1.00E-07
1.25E-07
2.00E-07
2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
128
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 1 @ +5V (A)
2.50E-07
2.00E-07
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.61. Plot of Negative Bias Current 1 @ +5V (A) versus total dose. The solid diamonds are the average of
the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
129
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.61. Raw data for Negative Bias Current 1 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Bias Current 1 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.33E-08
1.77E-08
2.64E-08
4.05E-08
6.56E-08
351
1.33E-08
1.80E-08
2.66E-08
4.05E-08
6.51E-08
352
1.35E-08
1.79E-08
2.64E-08
4.07E-08
6.53E-08
353
1.24E-08
1.71E-08
2.58E-08
4.00E-08
6.48E-08
354
1.28E-08
1.79E-08
2.66E-08
4.13E-08
6.79E-08
355
1.32E-08
1.77E-08
2.63E-08
3.96E-08
6.33E-08
356
1.25E-08
1.71E-08
2.55E-08
3.87E-08
6.15E-08
357
1.30E-08
1.74E-08
2.56E-08
3.84E-08
6.14E-08
358
1.34E-08
1.79E-08
2.62E-08
3.89E-08
6.13E-08
359
1.29E-08
1.71E-08
2.50E-08
3.77E-08
5.98E-08
360
1.34E-08
1.33E-08
1.33E-08
1.33E-08
1.33E-08
361
1.38E-08
1.37E-08
1.37E-08
1.37E-08
1.37E-08
Biased Statistics
Average Biased
1.31E-08
1.77E-08
2.64E-08
4.06E-08
6.57E-08
Std Dev Biased
4.24E-10
3.58E-10
3.50E-10
4.88E-10
1.26E-09
Ps90%/90% (+KTL) Biased
1.42E-08
1.87E-08
2.73E-08
4.19E-08
6.92E-08
Ps90%/90% (-KTL) Biased
1.19E-08
1.67E-08
2.54E-08
3.93E-08
6.23E-08
Un-Biased Statistics
Average Un-Biased
1.30E-08
1.74E-08
2.57E-08
3.86E-08
6.14E-08
Std Dev Un-Biased
3.53E-10
3.83E-10
5.34E-10
6.98E-10
1.24E-09
Ps90%/90% (+KTL) Un-Biased
1.40E-08
1.85E-08
2.72E-08
4.06E-08
6.48E-08
Ps90%/90% (-KTL) Un-Biased
1.20E-08
1.64E-08
2.43E-08
3.67E-08
5.81E-08
Specification MIN
-5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08
1.00E-07
1.25E-07
2.00E-07
2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
130
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 2 @ +5V (A)
2.50E-07
2.00E-07
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.62. Plot of Negative Bias Current 2 @ +5V (A) versus total dose. The solid diamonds are the average of
the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
131
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.62. Raw data for Negative Bias Current 2 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Bias Current 2 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.27E-08
1.67E-08
2.51E-08
3.85E-08
6.23E-08
351
1.23E-08
1.64E-08
2.44E-08
3.72E-08
5.99E-08
352
1.32E-08
1.73E-08
2.55E-08
3.88E-08
6.18E-08
353
1.18E-08
1.63E-08
2.50E-08
3.90E-08
6.33E-08
354
1.27E-08
1.74E-08
2.58E-08
3.99E-08
6.56E-08
355
1.27E-08
1.69E-08
2.51E-08
3.74E-08
6.01E-08
356
1.22E-08
1.66E-08
2.47E-08
3.73E-08
5.89E-08
357
1.24E-08
1.64E-08
2.41E-08
3.62E-08
5.76E-08
358
1.24E-08
1.67E-08
2.46E-08
3.70E-08
5.95E-08
359
1.25E-08
1.67E-08
2.43E-08
3.66E-08
5.84E-08
360
1.34E-08
1.32E-08
1.32E-08
1.32E-08
1.32E-08
361
1.20E-08
1.19E-08
1.19E-08
1.19E-08
1.19E-08
Biased Statistics
Average Biased
1.25E-08
1.68E-08
2.51E-08
3.87E-08
6.26E-08
Std Dev Biased
4.97E-10
5.19E-10
5.37E-10
9.88E-10
2.11E-09
Ps90%/90% (+KTL) Biased
1.39E-08
1.83E-08
2.66E-08
4.14E-08
6.84E-08
Ps90%/90% (-KTL) Biased
1.12E-08
1.54E-08
2.37E-08
3.60E-08
5.68E-08
Un-Biased Statistics
Average Un-Biased
1.24E-08
1.66E-08
2.46E-08
3.69E-08
5.89E-08
Std Dev Un-Biased
1.79E-10
1.87E-10
3.54E-10
5.17E-10
9.62E-10
Ps90%/90% (+KTL) Un-Biased
1.29E-08
1.72E-08
2.55E-08
3.83E-08
6.15E-08
Ps90%/90% (-KTL) Un-Biased
1.20E-08
1.61E-08
2.36E-08
3.55E-08
5.63E-08
Specification MIN
-5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08
1.00E-07
1.25E-07
2.00E-07
2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
132
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 3 @ +5V (A)
2.50E-07
2.00E-07
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.63. Plot of Negative Bias Current 3 @ +5V (A) versus total dose. The solid diamonds are the average of
the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
133
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.63. Raw data for Negative Bias Current 3 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Bias Current 3 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.32E-08
1.73E-08
2.58E-08
3.95E-08
6.37E-08
351
1.35E-08
1.78E-08
2.62E-08
3.99E-08
6.42E-08
352
1.30E-08
1.72E-08
2.52E-08
3.84E-08
6.17E-08
353
1.23E-08
1.68E-08
2.58E-08
4.02E-08
6.55E-08
354
1.25E-08
1.73E-08
2.54E-08
3.93E-08
6.48E-08
355
1.31E-08
1.74E-08
2.57E-08
3.84E-08
6.12E-08
356
1.32E-08
1.79E-08
2.65E-08
3.99E-08
6.31E-08
357
1.28E-08
1.69E-08
2.46E-08
3.71E-08
5.87E-08
358
1.28E-08
1.71E-08
2.53E-08
3.79E-08
6.09E-08
359
1.35E-08
1.78E-08
2.60E-08
3.91E-08
6.21E-08
360
1.40E-08
1.39E-08
1.39E-08
1.39E-08
1.39E-08
361
1.25E-08
1.24E-08
1.24E-08
1.24E-08
1.24E-08
Biased Statistics
Average Biased
1.29E-08
1.73E-08
2.57E-08
3.95E-08
6.40E-08
Std Dev Biased
5.00E-10
3.54E-10
3.88E-10
6.78E-10
1.44E-09
Ps90%/90% (+KTL) Biased
1.43E-08
1.83E-08
2.67E-08
4.13E-08
6.79E-08
Ps90%/90% (-KTL) Biased
1.15E-08
1.63E-08
2.46E-08
3.76E-08
6.00E-08
Un-Biased Statistics
Average Un-Biased
1.31E-08
1.74E-08
2.56E-08
3.85E-08
6.12E-08
Std Dev Un-Biased
3.28E-10
4.15E-10
7.07E-10
1.09E-09
1.64E-09
Ps90%/90% (+KTL) Un-Biased
1.40E-08
1.86E-08
2.76E-08
4.15E-08
6.57E-08
Ps90%/90% (-KTL) Un-Biased
1.22E-08
1.63E-08
2.37E-08
3.55E-08
5.67E-08
Specification MIN
-5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08
1.00E-07
1.25E-07
2.00E-07
2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
134
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
Negative Bias Current 4 @ +5V (A)
2.50E-07
2.00E-07
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
-2.00E-07
-2.50E-07
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.64. Plot of Negative Bias Current 4 @ +5V (A) versus total dose. The solid diamonds are the average of
the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
135
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.64. Raw data for Negative Bias Current 4 @ +5V (A) versus total dose, including the statistical analysis,
specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Negative Bias Current 4 @ +5V (A)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.28E-08
1.69E-08
2.53E-08
3.89E-08
6.30E-08
351
1.22E-08
1.65E-08
2.45E-08
3.74E-08
6.01E-08
352
1.23E-08
1.63E-08
2.44E-08
3.74E-08
6.02E-08
353
1.21E-08
1.67E-08
2.52E-08
3.90E-08
6.35E-08
354
1.25E-08
1.64E-08
2.56E-08
3.96E-08
6.50E-08
355
1.28E-08
1.72E-08
2.55E-08
3.82E-08
6.08E-08
356
1.28E-08
1.73E-08
2.57E-08
3.88E-08
6.12E-08
357
1.31E-08
1.76E-08
2.59E-08
3.85E-08
6.09E-08
358
1.23E-08
1.66E-08
2.43E-08
3.62E-08
5.72E-08
359
1.25E-08
1.65E-08
2.42E-08
3.63E-08
5.77E-08
360
1.30E-08
1.29E-08
1.30E-08
1.29E-08
1.30E-08
361
1.27E-08
1.25E-08
1.25E-08
1.25E-08
1.25E-08
Biased Statistics
Average Biased
1.24E-08
1.66E-08
2.50E-08
3.84E-08
6.24E-08
Std Dev Biased
2.78E-10
2.23E-10
5.35E-10
9.94E-10
2.15E-09
Ps90%/90% (+KTL) Biased
1.31E-08
1.72E-08
2.64E-08
4.12E-08
6.83E-08
Ps90%/90% (-KTL) Biased
1.16E-08
1.59E-08
2.35E-08
3.57E-08
5.65E-08
Un-Biased Statistics
Average Un-Biased
1.27E-08
1.70E-08
2.51E-08
3.76E-08
5.96E-08
Std Dev Un-Biased
3.07E-10
4.79E-10
8.16E-10
1.26E-09
1.94E-09
Ps90%/90% (+KTL) Un-Biased
1.35E-08
1.83E-08
2.73E-08
4.11E-08
6.49E-08
Ps90%/90% (-KTL) Un-Biased
1.19E-08
1.57E-08
2.29E-08
3.42E-08
5.42E-08
Specification MIN
-5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
Specification MAX
5.00E-08
1.00E-07
1.25E-07
2.00E-07
2.00E-07
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
136
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 1 RL=open @ +5V (V)
4.35E+00
4.30E+00
4.25E+00
4.20E+00
4.15E+00
4.10E+00
4.05E+00
4.00E+00
3.95E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.65. Plot of Positive Output Voltage 1 RL=open @ +5V (V) versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
137
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.65. Raw data for Positive Output Voltage 1 RL=open @ +5V (V) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 1 RL=open @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 4.27E+00 4.27E+00 4.28E+00 4.31E+00 4.33E+00
351 4.27E+00 4.27E+00 4.28E+00 4.31E+00 4.33E+00
352 4.27E+00 4.27E+00 4.28E+00 4.32E+00 4.33E+00
353 4.27E+00 4.28E+00 4.29E+00 4.32E+00 4.33E+00
354 4.27E+00 4.27E+00 4.29E+00 4.32E+00 4.33E+00
355 4.26E+00 4.27E+00 4.27E+00 4.29E+00 4.33E+00
356 4.27E+00 4.27E+00 4.28E+00 4.31E+00 4.33E+00
357 4.27E+00 4.27E+00 4.28E+00 4.30E+00 4.33E+00
358 4.27E+00 4.27E+00 4.28E+00 4.30E+00 4.33E+00
359 4.27E+00 4.27E+00 4.28E+00 4.30E+00 4.33E+00
360 4.27E+00 4.28E+00 4.29E+00 4.28E+00 4.29E+00
361 4.27E+00 4.28E+00 4.28E+00 4.28E+00 4.28E+00
Biased Statistics
Average Biased
4.27E+00 4.27E+00 4.28E+00 4.32E+00 4.33E+00
Std Dev Biased
2.55E-03
2.70E-03
3.91E-03
6.61E-03
3.74E-03
Ps90%/90% (+KTL) Biased
4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.34E+00
Ps90%/90% (-KTL) Biased
4.26E+00 4.26E+00 4.27E+00 4.30E+00 4.32E+00
Un-Biased Statistics
Average Un-Biased
4.27E+00 4.27E+00 4.28E+00 4.30E+00 4.33E+00
Std Dev Un-Biased
3.97E-03
3.24E-03
3.54E-03
5.31E-03
1.79E-03
Ps90%/90% (+KTL) Un-Biased
4.28E+00 4.28E+00 4.29E+00 4.32E+00 4.33E+00
Ps90%/90% (-KTL) Un-Biased
4.26E+00 4.26E+00 4.27E+00 4.29E+00 4.32E+00
Specification MIN
4.00E+00 4.00E+00 4.00E+00 4.00E+00 4.00E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
138
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 2 RL=open @ +5V (V)
4.35E+00
4.30E+00
4.25E+00
4.20E+00
4.15E+00
4.10E+00
4.05E+00
4.00E+00
3.95E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.66. Plot of Positive Output Voltage 2 RL=open @ +5V (V) versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
139
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.66. Raw data for Positive Output Voltage 2 RL=open @ +5V (V) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 2 RL=open @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 4.29E+00 4.29E+00 4.30E+00 4.33E+00 4.33E+00
351 4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
352 4.28E+00 4.29E+00 4.29E+00 4.33E+00 4.33E+00
353 4.29E+00 4.30E+00 4.31E+00 4.33E+00 4.34E+00
354 4.29E+00 4.29E+00 4.30E+00 4.33E+00 4.33E+00
355 4.27E+00 4.27E+00 4.29E+00 4.32E+00 4.33E+00
356 4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
357 4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
358 4.29E+00 4.29E+00 4.30E+00 4.33E+00 4.33E+00
359 4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
360 4.28E+00 4.29E+00 4.29E+00 4.29E+00 4.29E+00
361 4.28E+00 4.30E+00 4.30E+00 4.30E+00 4.30E+00
Biased Statistics
Average Biased
4.28E+00 4.29E+00 4.30E+00 4.33E+00 4.33E+00
Std Dev Biased
3.36E-03
6.50E-03
8.29E-03
3.94E-03
4.34E-03
Ps90%/90% (+KTL) Biased
4.29E+00 4.31E+00 4.32E+00 4.34E+00 4.34E+00
Ps90%/90% (-KTL) Biased
4.28E+00 4.27E+00 4.28E+00 4.32E+00 4.32E+00
Un-Biased Statistics
Average Un-Biased
4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
Std Dev Un-Biased
5.10E-03
3.96E-03
3.83E-03
2.51E-03
2.39E-03
Ps90%/90% (+KTL) Un-Biased
4.29E+00 4.29E+00 4.30E+00 4.33E+00 4.34E+00
Ps90%/90% (-KTL) Un-Biased
4.27E+00 4.27E+00 4.28E+00 4.32E+00 4.32E+00
Specification MIN
4.00E+00 4.00E+00 4.00E+00 4.00E+00 4.00E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
140
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 3 RL=open @ +5V (V)
4.35E+00
4.30E+00
4.25E+00
4.20E+00
4.15E+00
4.10E+00
4.05E+00
4.00E+00
3.95E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.67. Plot of Positive Output Voltage 3 RL=open @ +5V (V) versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
141
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.67. Raw data for Positive Output Voltage 3 RL=open @ +5V (V) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 3 RL=open @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 4.27E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
351 4.27E+00 4.27E+00 4.28E+00 4.31E+00 4.33E+00
352 4.27E+00 4.27E+00 4.28E+00 4.31E+00 4.33E+00
353 4.27E+00 4.28E+00 4.29E+00 4.34E+00 4.34E+00
354 4.27E+00 4.27E+00 4.28E+00 4.31E+00 4.33E+00
355 4.26E+00 4.27E+00 4.27E+00 4.30E+00 4.33E+00
356 4.27E+00 4.27E+00 4.28E+00 4.31E+00 4.33E+00
357 4.27E+00 4.27E+00 4.28E+00 4.31E+00 4.33E+00
358 4.28E+00 4.28E+00 4.28E+00 4.31E+00 4.33E+00
359 4.27E+00 4.27E+00 4.28E+00 4.30E+00 4.33E+00
360 4.27E+00 4.28E+00 4.28E+00 4.28E+00 4.28E+00
361 4.27E+00 4.28E+00 4.28E+00 4.28E+00 4.28E+00
Biased Statistics
Average Biased
4.27E+00 4.28E+00 4.28E+00 4.32E+00 4.33E+00
Std Dev Biased
2.79E-03
5.07E-03
5.94E-03
1.29E-02
4.32E-03
Ps90%/90% (+KTL) Biased
4.28E+00 4.29E+00 4.30E+00 4.35E+00 4.34E+00
Ps90%/90% (-KTL) Biased
4.26E+00 4.26E+00 4.27E+00 4.28E+00 4.32E+00
Un-Biased Statistics
Average Un-Biased
4.27E+00 4.27E+00 4.28E+00 4.30E+00 4.33E+00
Std Dev Un-Biased
4.39E-03
3.56E-03
3.27E-03
3.85E-03
2.61E-03
Ps90%/90% (+KTL) Un-Biased
4.28E+00 4.28E+00 4.29E+00 4.32E+00 4.34E+00
Ps90%/90% (-KTL) Un-Biased
4.26E+00 4.26E+00 4.27E+00 4.29E+00 4.32E+00
Specification MIN
4.00E+00 4.00E+00 4.00E+00 4.00E+00 4.00E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
142
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 4 RL=open @ +5V (V)
4.35E+00
4.30E+00
4.25E+00
4.20E+00
4.15E+00
4.10E+00
4.05E+00
4.00E+00
3.95E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.68. Plot of Positive Output Voltage 4 RL=open @ +5V (V) versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
143
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.68. Raw data for Positive Output Voltage 4 RL=open @ +5V (V) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 4 RL=open @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
351 4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
352 4.28E+00 4.28E+00 4.30E+00 4.32E+00 4.32E+00
353 4.28E+00 4.29E+00 4.30E+00 4.33E+00 4.33E+00
354 4.29E+00 4.28E+00 4.30E+00 4.33E+00 4.33E+00
355 4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
356 4.29E+00 4.28E+00 4.30E+00 4.33E+00 4.33E+00
357 4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
358 4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
359 4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
360 4.28E+00 4.30E+00 4.30E+00 4.30E+00 4.30E+00
361 4.28E+00 4.29E+00 4.29E+00 4.29E+00 4.29E+00
Biased Statistics
Average Biased
4.28E+00 4.28E+00 4.30E+00 4.33E+00 4.33E+00
Std Dev Biased
3.94E-03
2.88E-03
5.46E-03
4.02E-03
4.28E-03
Ps90%/90% (+KTL) Biased
4.29E+00 4.29E+00 4.31E+00 4.34E+00 4.34E+00
Ps90%/90% (-KTL) Biased
4.27E+00 4.27E+00 4.28E+00 4.32E+00 4.32E+00
Un-Biased Statistics
Average Un-Biased
4.28E+00 4.28E+00 4.29E+00 4.33E+00 4.33E+00
Std Dev Un-Biased
4.04E-03
3.27E-03
3.65E-03
1.73E-03
1.79E-03
Ps90%/90% (+KTL) Un-Biased
4.29E+00 4.29E+00 4.30E+00 4.33E+00 4.33E+00
Ps90%/90% (-KTL) Un-Biased
4.27E+00 4.27E+00 4.28E+00 4.32E+00 4.32E+00
Specification MIN
4.00E+00 4.00E+00 4.00E+00 4.00E+00 4.00E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
144
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 1 RL=600 @ +5V (V)
4.50E+00
4.00E+00
3.50E+00
3.00E+00
2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.69. Plot of Positive Output Voltage 1 RL=600 @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
145
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.69. Raw data for Positive Output Voltage 1 RL=600 @ +5V (V) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 1 RL=600 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
351 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
352 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
353 3.85E+00 3.86E+00 3.86E+00 3.85E+00 3.85E+00
354 3.85E+00 3.84E+00 3.86E+00 3.85E+00 3.85E+00
355 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00
356 3.84E+00 3.86E+00 3.85E+00 3.85E+00 3.84E+00
357 3.84E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00
358 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
359 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
360 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00
361 3.83E+00 3.84E+00 3.85E+00 3.84E+00 3.84E+00
Biased Statistics
Average Biased
3.84E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00
Std Dev Biased
8.22E-03
7.28E-03
9.04E-03
9.31E-03
1.04E-02
Ps90%/90% (+KTL) Biased
3.86E+00 3.86E+00 3.87E+00 3.87E+00 3.87E+00
Ps90%/90% (-KTL) Biased
3.81E+00 3.83E+00 3.82E+00 3.82E+00 3.81E+00
Un-Biased Statistics
Average Un-Biased
3.84E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00
Std Dev Un-Biased
5.55E-03
5.32E-03
5.55E-03
5.45E-03
5.79E-03
Ps90%/90% (+KTL) Un-Biased
3.85E+00 3.86E+00 3.86E+00 3.86E+00 3.85E+00
Ps90%/90% (-KTL) Un-Biased
3.82E+00 3.83E+00 3.83E+00 3.83E+00 3.82E+00
Specification MIN
3.40E+00 3.20E+00 3.00E+00 2.80E+00 2.80E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
146
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 2 RL=600 @ +5V (V)
4.50E+00
4.00E+00
3.50E+00
3.00E+00
2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.70. Plot of Positive Output Voltage 2 RL=600 @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
147
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.70. Raw data for Positive Output Voltage 2 RL=600 @ +5V (V) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 2 RL=600 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 3.82E+00 3.83E+00 3.83E+00 3.83E+00 3.82E+00
351 3.82E+00 3.83E+00 3.83E+00 3.83E+00 3.82E+00
352 3.83E+00 3.84E+00 3.84E+00 3.83E+00 3.83E+00
353 3.84E+00 3.86E+00 3.85E+00 3.85E+00 3.85E+00
354 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
355 3.83E+00 3.84E+00 3.84E+00 3.83E+00 3.83E+00
356 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
357 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
358 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00
359 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
360 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00
361 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00
Biased Statistics
Average Biased
3.83E+00 3.84E+00 3.84E+00 3.83E+00 3.83E+00
Std Dev Biased
8.96E-03
9.43E-03
9.36E-03
9.84E-03
1.06E-02
Ps90%/90% (+KTL) Biased
3.85E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00
Ps90%/90% (-KTL) Biased
3.80E+00 3.81E+00 3.81E+00 3.81E+00 3.80E+00
Un-Biased Statistics
Average Un-Biased
3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
Std Dev Un-Biased
4.56E-03
4.87E-03
5.03E-03
5.64E-03
5.77E-03
Ps90%/90% (+KTL) Un-Biased
3.85E+00 3.86E+00 3.86E+00 3.85E+00 3.85E+00
Ps90%/90% (-KTL) Un-Biased
3.82E+00 3.83E+00 3.83E+00 3.82E+00 3.82E+00
Specification MIN
3.40E+00 3.20E+00 3.00E+00 2.80E+00 2.80E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
148
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 3 RL=600 @ +5V (V)
4.50E+00
4.00E+00
3.50E+00
3.00E+00
2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.71. Plot of Positive Output Voltage 3 RL=600 @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
149
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.71. Raw data for Positive Output Voltage 3 RL=600 @ +5V (V) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 3 RL=600 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
351 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
352 3.84E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00
353 3.85E+00 3.86E+00 3.86E+00 3.86E+00 3.85E+00
354 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00
355 3.84E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00
356 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00
357 3.84E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00
358 3.85E+00 3.86E+00 3.86E+00 3.86E+00 3.85E+00
359 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00
360 3.83E+00 3.84E+00 3.84E+00 3.85E+00 3.85E+00
361 3.85E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00
Biased Statistics
Average Biased
3.84E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00
Std Dev Biased
8.87E-03
8.96E-03
9.18E-03
9.74E-03
1.02E-02
Ps90%/90% (+KTL) Biased
3.86E+00 3.87E+00 3.87E+00 3.87E+00 3.87E+00
Ps90%/90% (-KTL) Biased
3.81E+00 3.82E+00 3.82E+00 3.82E+00 3.81E+00
Un-Biased Statistics
Average Un-Biased
3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00
Std Dev Un-Biased
5.61E-03
6.02E-03
6.02E-03
6.16E-03
6.98E-03
Ps90%/90% (+KTL) Un-Biased
3.86E+00 3.87E+00 3.87E+00 3.86E+00 3.86E+00
Ps90%/90% (-KTL) Un-Biased
3.83E+00 3.84E+00 3.83E+00 3.83E+00 3.82E+00
Specification MIN
3.40E+00 3.20E+00 3.00E+00 2.80E+00 2.80E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
150
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Positive Output Voltage 4 RL=600 @ +5V (V)
4.50E+00
4.00E+00
3.50E+00
3.00E+00
2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.72. Plot of Positive Output Voltage 4 RL=600 @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
151
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.72. Raw data for Positive Output Voltage 4 RL=600 @ +5V (V) versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Positive Output Voltage 4 RL=600 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350 3.82E+00 3.83E+00 3.83E+00 3.83E+00 3.82E+00
351 3.82E+00 3.83E+00 3.83E+00 3.83E+00 3.82E+00
352 3.82E+00 3.83E+00 3.83E+00 3.83E+00 3.82E+00
353 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00
354 3.84E+00 3.83E+00 3.85E+00 3.85E+00 3.84E+00
355 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00
356 3.84E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00
357 3.83E+00 3.84E+00 3.84E+00 3.83E+00 3.83E+00
358 3.82E+00 3.83E+00 3.83E+00 3.83E+00 3.82E+00
359 3.82E+00 3.83E+00 3.83E+00 3.83E+00 3.82E+00
360 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00
361 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00
Biased Statistics
Average Biased
3.83E+00 3.84E+00 3.84E+00 3.83E+00 3.83E+00
Std Dev Biased
1.01E-02
8.26E-03
1.07E-02
1.07E-02
1.18E-02
Ps90%/90% (+KTL) Biased
3.86E+00 3.86E+00 3.87E+00 3.86E+00 3.86E+00
Ps90%/90% (-KTL) Biased
3.80E+00 3.81E+00 3.81E+00 3.80E+00 3.80E+00
Un-Biased Statistics
Average Un-Biased
3.83E+00 3.84E+00 3.84E+00 3.83E+00 3.83E+00
Std Dev Un-Biased
5.46E-03
5.46E-03
5.76E-03
5.61E-03
5.76E-03
Ps90%/90% (+KTL) Un-Biased
3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00
Ps90%/90% (-KTL) Un-Biased
3.81E+00 3.82E+00 3.82E+00 3.82E+00 3.81E+00
Specification MIN
3.40E+00 3.20E+00 3.00E+00 2.80E+00 2.80E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
152
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 1 RL=open @ +5V (V)
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.73. Plot of Output Voltage Low 1 RL=open @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
153
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.73. Raw data for Output Voltage Low 1 RL=open @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 1 RL=open @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.38E-02
1.37E-02
1.37E-02
1.40E-02
1.44E-02
351
1.39E-02
1.37E-02
1.39E-02
1.42E-02
1.44E-02
352
1.38E-02
1.36E-02
1.38E-02
1.40E-02
1.44E-02
353
1.39E-02
1.40E-02
1.40E-02
1.42E-02
1.43E-02
354
1.40E-02
1.37E-02
1.39E-02
1.40E-02
1.44E-02
355
1.38E-02
1.37E-02
1.37E-02
1.42E-02
1.51E-02
356
1.40E-02
1.37E-02
1.41E-02
1.42E-02
1.51E-02
357
1.37E-02
1.37E-02
1.38E-02
1.43E-02
1.51E-02
358
1.37E-02
1.38E-02
1.38E-02
1.42E-02
1.50E-02
359
1.40E-02
1.37E-02
1.38E-02
1.42E-02
1.52E-02
360
1.39E-02
1.37E-02
1.37E-02
1.38E-02
1.38E-02
361
1.39E-02
1.37E-02
1.36E-02
1.37E-02
1.37E-02
Biased Statistics
Average Biased
1.39E-02
1.37E-02
1.39E-02
1.41E-02
1.44E-02
Std Dev Biased
8.37E-05
1.52E-04
1.14E-04
1.10E-04
4.47E-05
Ps90%/90% (+KTL) Biased
1.41E-02
1.42E-02
1.42E-02
1.44E-02
1.45E-02
Ps90%/90% (-KTL) Biased
1.37E-02
1.33E-02
1.35E-02
1.38E-02
1.43E-02
Un-Biased Statistics
Average Un-Biased
1.38E-02
1.37E-02
1.38E-02
1.42E-02
1.51E-02
Std Dev Un-Biased
1.52E-04
4.47E-05
1.52E-04
4.47E-05
7.07E-05
Ps90%/90% (+KTL) Un-Biased
1.43E-02
1.38E-02
1.43E-02
1.43E-02
1.53E-02
Ps90%/90% (-KTL) Un-Biased
1.34E-02
1.36E-02
1.34E-02
1.41E-02
1.49E-02
5.00E-02
Specification MAX
2.50E-02
3.00E-02
4.00E-02
5.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
154
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 2 RL=open @ +5V (V)
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.74. Plot of Output Voltage Low 2 RL=open @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
155
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.74. Raw data for Output Voltage Low 2 RL=open @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 2 RL=open @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.39E-02
1.39E-02
1.39E-02
1.41E-02
1.44E-02
351
1.40E-02
1.38E-02
1.40E-02
1.42E-02
1.45E-02
352
1.39E-02
1.40E-02
1.37E-02
1.41E-02
1.43E-02
353
1.41E-02
1.41E-02
1.42E-02
1.44E-02
1.46E-02
354
1.40E-02
1.38E-02
1.41E-02
1.41E-02
1.45E-02
355
1.38E-02
1.37E-02
1.40E-02
1.42E-02
1.51E-02
356
1.40E-02
1.40E-02
1.42E-02
1.45E-02
1.51E-02
357
1.38E-02
1.38E-02
1.39E-02
1.42E-02
1.51E-02
358
1.39E-02
1.38E-02
1.40E-02
1.42E-02
1.50E-02
359
1.38E-02
1.39E-02
1.40E-02
1.43E-02
1.48E-02
360
1.38E-02
1.37E-02
1.36E-02
1.37E-02
1.37E-02
361
1.41E-02
1.40E-02
1.40E-02
1.40E-02
1.40E-02
Biased Statistics
Average Biased
1.40E-02
1.39E-02
1.40E-02
1.42E-02
1.45E-02
Std Dev Biased
8.37E-05
1.30E-04
1.92E-04
1.30E-04
1.14E-04
Ps90%/90% (+KTL) Biased
1.42E-02
1.43E-02
1.45E-02
1.45E-02
1.48E-02
Ps90%/90% (-KTL) Biased
1.38E-02
1.36E-02
1.35E-02
1.38E-02
1.41E-02
Un-Biased Statistics
Average Un-Biased
1.39E-02
1.38E-02
1.40E-02
1.43E-02
1.50E-02
Std Dev Un-Biased
8.94E-05
1.14E-04
1.10E-04
1.30E-04
1.30E-04
Ps90%/90% (+KTL) Un-Biased
1.41E-02
1.42E-02
1.43E-02
1.46E-02
1.54E-02
Ps90%/90% (-KTL) Un-Biased
1.36E-02
1.35E-02
1.37E-02
1.39E-02
1.47E-02
5.00E-02
Specification MAX
2.50E-02
3.00E-02
4.00E-02
5.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
156
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 3 RL=open @ +5V (V)
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.75. Plot of Output Voltage Low 3 RL=open @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
157
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.75. Raw data for Output Voltage Low 3 RL=open @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 3 RL=open @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.38E-02
1.37E-02
1.40E-02
1.41E-02
1.44E-02
351
1.38E-02
1.37E-02
1.38E-02
1.40E-02
1.42E-02
352
1.37E-02
1.38E-02
1.39E-02
1.40E-02
1.43E-02
353
1.40E-02
1.40E-02
1.42E-02
1.42E-02
1.44E-02
354
1.40E-02
1.38E-02
1.40E-02
1.41E-02
1.45E-02
355
1.39E-02
1.38E-02
1.40E-02
1.43E-02
1.52E-02
356
1.39E-02
1.39E-02
1.41E-02
1.45E-02
1.51E-02
357
1.38E-02
1.37E-02
1.40E-02
1.42E-02
1.50E-02
358
1.38E-02
1.37E-02
1.39E-02
1.42E-02
1.47E-02
359
1.38E-02
1.37E-02
1.39E-02
1.42E-02
1.50E-02
360
1.37E-02
1.36E-02
1.37E-02
1.38E-02
1.36E-02
361
1.42E-02
1.40E-02
1.40E-02
1.39E-02
1.40E-02
Biased Statistics
Average Biased
1.39E-02
1.38E-02
1.40E-02
1.41E-02
1.44E-02
Std Dev Biased
1.34E-04
1.22E-04
1.48E-04
8.37E-05
1.14E-04
Ps90%/90% (+KTL) Biased
1.42E-02
1.41E-02
1.44E-02
1.43E-02
1.47E-02
Ps90%/90% (-KTL) Biased
1.35E-02
1.35E-02
1.36E-02
1.39E-02
1.40E-02
Un-Biased Statistics
Average Un-Biased
1.38E-02
1.38E-02
1.40E-02
1.43E-02
1.50E-02
Std Dev Un-Biased
5.48E-05
8.94E-05
8.37E-05
1.30E-04
1.87E-04
Ps90%/90% (+KTL) Un-Biased
1.40E-02
1.40E-02
1.42E-02
1.46E-02
1.55E-02
Ps90%/90% (-KTL) Un-Biased
1.37E-02
1.35E-02
1.38E-02
1.39E-02
1.45E-02
5.00E-02
Specification MAX
2.50E-02
3.00E-02
4.00E-02
5.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
158
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 4 RL=open @ +5V (V)
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.76. Plot of Output Voltage Low 4 RL=open @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
159
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.76. Raw data for Output Voltage Low 4 RL=open @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 4 RL=open @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
1.39E-02
1.37E-02
1.39E-02
1.41E-02
1.44E-02
351
1.39E-02
1.37E-02
1.41E-02
1.41E-02
1.44E-02
352
1.38E-02
1.37E-02
1.39E-02
1.40E-02
1.43E-02
353
1.40E-02
1.40E-02
1.41E-02
1.41E-02
1.45E-02
354
1.40E-02
1.36E-02
1.41E-02
1.42E-02
1.44E-02
355
1.38E-02
1.39E-02
1.40E-02
1.42E-02
1.52E-02
356
1.40E-02
1.40E-02
1.42E-02
1.45E-02
1.53E-02
357
1.39E-02
1.39E-02
1.41E-02
1.44E-02
1.52E-02
358
1.38E-02
1.39E-02
1.41E-02
1.42E-02
1.51E-02
359
1.39E-02
1.40E-02
1.40E-02
1.44E-02
1.51E-02
360
1.39E-02
1.39E-02
1.38E-02
1.39E-02
1.38E-02
361
1.40E-02
1.38E-02
1.37E-02
1.38E-02
1.38E-02
Biased Statistics
Average Biased
1.39E-02
1.37E-02
1.40E-02
1.41E-02
1.44E-02
Std Dev Biased
8.37E-05
1.52E-04
1.10E-04
7.07E-05
7.07E-05
Ps90%/90% (+KTL) Biased
1.41E-02
1.42E-02
1.43E-02
1.43E-02
1.46E-02
Ps90%/90% (-KTL) Biased
1.37E-02
1.33E-02
1.37E-02
1.39E-02
1.42E-02
Un-Biased Statistics
Average Un-Biased
1.39E-02
1.39E-02
1.41E-02
1.43E-02
1.52E-02
Std Dev Un-Biased
8.37E-05
5.48E-05
8.37E-05
1.34E-04
8.37E-05
Ps90%/90% (+KTL) Un-Biased
1.41E-02
1.41E-02
1.43E-02
1.47E-02
1.54E-02
Ps90%/90% (-KTL) Un-Biased
1.37E-02
1.38E-02
1.39E-02
1.40E-02
1.50E-02
5.00E-02
Specification MAX
2.50E-02
3.00E-02
4.00E-02
5.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
160
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 1 RL=600 @ +5V (V)
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.77. Plot of Output Voltage Low 1 RL=600 @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
161
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.77. Raw data for Output Voltage Low 1 RL=600 @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 1 RL=600 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
6.50E-03
4.60E-03
4.30E-03
4.10E-03
3.40E-03
351
6.40E-03
4.50E-03
4.30E-03
4.00E-03
3.40E-03
352
6.50E-03
4.70E-03
4.40E-03
4.20E-03
3.60E-03
353
6.60E-03
4.70E-03
4.60E-03
4.20E-03
3.50E-03
354
6.50E-03
4.60E-03
4.60E-03
4.20E-03
3.50E-03
355
6.50E-03
4.80E-03
4.60E-03
4.40E-03
3.90E-03
356
6.40E-03
4.60E-03
4.60E-03
4.30E-03
3.60E-03
357
6.50E-03
4.50E-03
4.50E-03
4.10E-03
3.60E-03
358
6.30E-03
4.50E-03
4.40E-03
4.10E-03
3.50E-03
359
6.30E-03
4.50E-03
4.30E-03
4.20E-03
3.50E-03
360
6.30E-03
4.40E-03
4.40E-03
4.50E-03
4.50E-03
361
6.30E-03
4.40E-03
4.50E-03
4.50E-03
4.40E-03
Biased Statistics
Average Biased
6.50E-03
4.62E-03
4.44E-03
4.14E-03
3.48E-03
Std Dev Biased
7.07E-05
8.37E-05
1.52E-04
8.94E-05
8.37E-05
Ps90%/90% (+KTL) Biased
6.69E-03
4.85E-03
4.86E-03
4.39E-03
3.71E-03
Ps90%/90% (-KTL) Biased
6.31E-03
4.39E-03
4.02E-03
3.89E-03
3.25E-03
Un-Biased Statistics
Average Un-Biased
6.40E-03
4.58E-03
4.48E-03
4.22E-03
3.62E-03
Std Dev Un-Biased
1.00E-04
1.30E-04
1.30E-04
1.30E-04
1.64E-04
Ps90%/90% (+KTL) Un-Biased
6.67E-03
4.94E-03
4.84E-03
4.58E-03
4.07E-03
Ps90%/90% (-KTL) Un-Biased
6.13E-03
4.22E-03
4.12E-03
3.86E-03
3.17E-03
1.00E-02
Specification MAX
1.00E-02
1.00E-02
1.00E-02
1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
162
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 2 RL=600 @ +5V (V)
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.78. Plot of Output Voltage Low 2 RL=600 @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
163
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.78. Raw data for Output Voltage Low 2 RL=600 @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 2 RL=600 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
6.10E-03
4.30E-03
4.20E-03
3.90E-03
3.10E-03
351
6.20E-03
4.40E-03
4.10E-03
4.00E-03
3.30E-03
352
6.30E-03
4.30E-03
4.10E-03
4.00E-03
3.30E-03
353
6.30E-03
4.40E-03
4.20E-03
4.00E-03
3.20E-03
354
6.20E-03
4.50E-03
4.30E-03
3.90E-03
3.30E-03
355
6.30E-03
4.50E-03
4.50E-03
4.20E-03
3.60E-03
356
6.20E-03
4.50E-03
4.30E-03
4.10E-03
3.50E-03
357
6.20E-03
4.30E-03
4.30E-03
4.00E-03
3.30E-03
358
6.30E-03
4.50E-03
4.40E-03
4.10E-03
3.60E-03
359
6.20E-03
4.50E-03
4.30E-03
4.00E-03
3.50E-03
360
6.10E-03
4.40E-03
4.30E-03
4.30E-03
4.20E-03
361
6.50E-03
4.60E-03
4.60E-03
4.70E-03
4.60E-03
Biased Statistics
Average Biased
6.22E-03
4.38E-03
4.18E-03
3.96E-03
3.24E-03
Std Dev Biased
8.37E-05
8.37E-05
8.37E-05
5.48E-05
8.94E-05
Ps90%/90% (+KTL) Biased
6.45E-03
4.61E-03
4.41E-03
4.11E-03
3.49E-03
Ps90%/90% (-KTL) Biased
5.99E-03
4.15E-03
3.95E-03
3.81E-03
2.99E-03
Un-Biased Statistics
Average Un-Biased
6.24E-03
4.46E-03
4.36E-03
4.08E-03
3.50E-03
Std Dev Un-Biased
5.48E-05
8.94E-05
8.94E-05
8.37E-05
1.22E-04
Ps90%/90% (+KTL) Un-Biased
6.39E-03
4.71E-03
4.61E-03
4.31E-03
3.84E-03
Ps90%/90% (-KTL) Un-Biased
6.09E-03
4.21E-03
4.11E-03
3.85E-03
3.16E-03
1.00E-02
Specification MAX
1.00E-02
1.00E-02
1.00E-02
1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
164
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 3 RL=600 @ +5V (V)
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.79. Plot of Output Voltage Low 3 RL=600 @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
165
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.79. Raw data for Output Voltage Low 3 RL=600 @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 3 RL=600 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
6.30E-03
4.60E-03
4.50E-03
4.20E-03
3.50E-03
351
6.30E-03
4.60E-03
4.40E-03
4.20E-03
3.50E-03
352
6.40E-03
4.60E-03
4.60E-03
4.10E-03
3.70E-03
353
6.50E-03
4.70E-03
4.60E-03
4.20E-03
3.60E-03
354
6.50E-03
4.70E-03
4.50E-03
4.20E-03
3.50E-03
355
6.50E-03
4.80E-03
4.80E-03
4.50E-03
3.80E-03
356
6.50E-03
4.80E-03
4.50E-03
4.30E-03
3.80E-03
357
6.50E-03
4.70E-03
4.70E-03
4.20E-03
3.80E-03
358
6.50E-03
4.90E-03
4.70E-03
4.50E-03
3.80E-03
359
6.40E-03
4.80E-03
4.70E-03
4.50E-03
3.90E-03
360
6.40E-03
4.50E-03
4.60E-03
4.50E-03
4.50E-03
361
6.60E-03
4.70E-03
4.80E-03
4.80E-03
4.80E-03
Biased Statistics
Average Biased
6.40E-03
4.64E-03
4.52E-03
4.18E-03
3.56E-03
Std Dev Biased
1.00E-04
5.48E-05
8.37E-05
4.47E-05
8.94E-05
Ps90%/90% (+KTL) Biased
6.67E-03
4.79E-03
4.75E-03
4.30E-03
3.81E-03
Ps90%/90% (-KTL) Biased
6.13E-03
4.49E-03
4.29E-03
4.06E-03
3.31E-03
Un-Biased Statistics
Average Un-Biased
6.48E-03
4.80E-03
4.68E-03
4.40E-03
3.82E-03
Std Dev Un-Biased
4.47E-05
7.07E-05
1.10E-04
1.41E-04
4.47E-05
Ps90%/90% (+KTL) Un-Biased
6.60E-03
4.99E-03
4.98E-03
4.79E-03
3.94E-03
Ps90%/90% (-KTL) Un-Biased
6.36E-03
4.61E-03
4.38E-03
4.01E-03
3.70E-03
1.00E-02
Specification MAX
1.00E-02
1.00E-02
1.00E-02
1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
166
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 4 RL=600 @ +5V (V)
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.80. Plot of Output Voltage Low 4 RL=600 @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
167
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.80. Raw data for Output Voltage Low 4 RL=600 @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 4 RL=600 @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
6.20E-03
4.30E-03
4.20E-03
4.00E-03
3.30E-03
351
6.20E-03
4.50E-03
4.30E-03
3.90E-03
3.30E-03
352
6.30E-03
4.60E-03
4.40E-03
4.20E-03
3.50E-03
353
6.40E-03
4.70E-03
4.60E-03
4.10E-03
3.60E-03
354
6.30E-03
4.50E-03
4.40E-03
4.10E-03
3.50E-03
355
6.40E-03
4.70E-03
4.40E-03
4.30E-03
3.80E-03
356
6.30E-03
4.60E-03
4.40E-03
4.20E-03
3.70E-03
357
6.20E-03
4.60E-03
4.30E-03
4.10E-03
3.60E-03
358
6.10E-03
4.30E-03
4.30E-03
4.00E-03
3.50E-03
359
6.10E-03
4.40E-03
4.30E-03
4.10E-03
3.40E-03
360
6.30E-03
4.20E-03
4.30E-03
4.40E-03
4.30E-03
361
6.10E-03
4.20E-03
4.30E-03
4.20E-03
4.40E-03
Biased Statistics
Average Biased
6.28E-03
4.52E-03
4.38E-03
4.06E-03
3.44E-03
Std Dev Biased
8.37E-05
1.48E-04
1.48E-04
1.14E-04
1.34E-04
Ps90%/90% (+KTL) Biased
6.51E-03
4.93E-03
4.79E-03
4.37E-03
3.81E-03
Ps90%/90% (-KTL) Biased
6.05E-03
4.11E-03
3.97E-03
3.75E-03
3.07E-03
Un-Biased Statistics
Average Un-Biased
6.22E-03
4.52E-03
4.34E-03
4.14E-03
3.60E-03
Std Dev Un-Biased
1.30E-04
1.64E-04
5.48E-05
1.14E-04
1.58E-04
Ps90%/90% (+KTL) Un-Biased
6.58E-03
4.97E-03
4.49E-03
4.45E-03
4.03E-03
Ps90%/90% (-KTL) Un-Biased
5.86E-03
4.07E-03
4.19E-03
3.83E-03
3.17E-03
1.00E-02
Specification MAX
1.00E-02
1.00E-02
1.00E-02
1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
168
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 1 IL=1mA @ +5V (V)
1.80E+00
1.60E+00
1.40E+00
1.20E+00
1.00E+00
8.00E-01
6.00E-01
4.00E-01
2.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.81. Plot of Output Voltage Low 1 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
169
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.81. Raw data for Output Voltage Low 1 IL=1mA @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 1 IL=1mA @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
2.38E-01
2.34E-01
2.38E-01
2.44E-01
2.69E-01
351
2.40E-01
2.36E-01
2.39E-01
2.45E-01
2.69E-01
352
2.34E-01
2.31E-01
2.35E-01
2.41E-01
2.68E-01
353
2.38E-01
2.35E-01
2.38E-01
2.45E-01
2.68E-01
354
2.39E-01
2.31E-01
2.38E-01
2.45E-01
2.69E-01
355
2.36E-01
2.32E-01
2.35E-01
2.40E-01
2.60E-01
356
2.39E-01
2.35E-01
2.37E-01
2.44E-01
2.66E-01
357
2.39E-01
2.34E-01
2.37E-01
2.43E-01
2.65E-01
358
2.40E-01
2.35E-01
2.38E-01
2.44E-01
2.67E-01
359
2.40E-01
2.35E-01
2.38E-01
2.44E-01
2.66E-01
360
2.39E-01
2.37E-01
2.37E-01
2.38E-01
2.37E-01
361
2.39E-01
2.37E-01
2.37E-01
2.38E-01
2.36E-01
Biased Statistics
Average Biased
2.38E-01
2.33E-01
2.38E-01
2.44E-01
2.69E-01
Std Dev Biased
2.28E-03
2.30E-03
1.52E-03
1.73E-03
5.48E-04
Ps90%/90% (+KTL) Biased
2.44E-01
2.40E-01
2.42E-01
2.49E-01
2.70E-01
Ps90%/90% (-KTL) Biased
2.32E-01
2.27E-01
2.33E-01
2.39E-01
2.67E-01
Un-Biased Statistics
Average Un-Biased
2.39E-01
2.34E-01
2.37E-01
2.43E-01
2.65E-01
Std Dev Un-Biased
1.64E-03
1.30E-03
1.22E-03
1.73E-03
2.77E-03
Ps90%/90% (+KTL) Un-Biased
2.43E-01
2.38E-01
2.40E-01
2.48E-01
2.72E-01
Ps90%/90% (-KTL) Un-Biased
2.34E-01
2.31E-01
2.34E-01
2.38E-01
2.57E-01
Specification MAX
3.50E-01
8.00E-01 1.00E+00 1.60E+00 1.60E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
170
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 2 IL=1mA @ +5V (V)
1.80E+00
1.60E+00
1.40E+00
1.20E+00
1.00E+00
8.00E-01
6.00E-01
4.00E-01
2.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.82. Plot of Output Voltage Low 2 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
171
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.82. Raw data for Output Voltage Low 2 IL=1mA @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 2 IL=1mA @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
2.44E-01
2.40E-01
2.43E-01
2.51E-01
2.90E-01
351
2.45E-01
2.41E-01
2.44E-01
2.51E-01
2.81E-01
352
2.45E-01
2.41E-01
2.44E-01
2.51E-01
2.78E-01
353
2.43E-01
2.42E-01
2.45E-01
2.53E-01
3.03E-01
354
2.45E-01
2.42E-01
2.44E-01
2.52E-01
2.83E-01
355
2.39E-01
2.36E-01
2.39E-01
2.45E-01
2.75E-01
356
2.43E-01
2.38E-01
2.42E-01
2.49E-01
2.78E-01
357
2.43E-01
2.38E-01
2.42E-01
2.49E-01
2.82E-01
358
2.41E-01
2.36E-01
2.39E-01
2.46E-01
2.75E-01
359
2.42E-01
2.38E-01
2.40E-01
2.47E-01
2.74E-01
360
2.45E-01
2.43E-01
2.42E-01
2.43E-01
2.42E-01
361
2.39E-01
2.38E-01
2.38E-01
2.38E-01
2.37E-01
Biased Statistics
Average Biased
2.44E-01
2.41E-01
2.44E-01
2.52E-01
2.87E-01
Std Dev Biased
8.94E-04
8.37E-04
7.07E-04
8.94E-04
9.97E-03
Ps90%/90% (+KTL) Biased
2.47E-01
2.43E-01
2.46E-01
2.54E-01
3.14E-01
Ps90%/90% (-KTL) Biased
2.42E-01
2.39E-01
2.42E-01
2.49E-01
2.60E-01
Un-Biased Statistics
Average Un-Biased
2.42E-01
2.37E-01
2.40E-01
2.47E-01
2.77E-01
Std Dev Un-Biased
1.67E-03
1.10E-03
1.52E-03
1.79E-03
3.27E-03
Ps90%/90% (+KTL) Un-Biased
2.46E-01
2.40E-01
2.45E-01
2.52E-01
2.86E-01
Ps90%/90% (-KTL) Un-Biased
2.37E-01
2.34E-01
2.36E-01
2.42E-01
2.68E-01
Specification MAX
3.50E-01
8.00E-01 1.00E+00 1.60E+00 1.60E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
172
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 3 IL=1mA @ +5V (V)
1.80E+00
1.60E+00
1.40E+00
1.20E+00
1.00E+00
8.00E-01
6.00E-01
4.00E-01
2.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.83. Plot of Output Voltage Low 3 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
173
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.83. Raw data for Output Voltage Low 3 IL=1mA @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 3 IL=1mA @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
2.39E-01
2.36E-01
2.39E-01
2.46E-01
2.74E-01
351
2.40E-01
2.35E-01
2.38E-01
2.45E-01
2.66E-01
352
2.39E-01
2.36E-01
2.39E-01
2.45E-01
2.65E-01
353
2.39E-01
2.37E-01
2.40E-01
2.47E-01
2.76E-01
354
2.40E-01
2.37E-01
2.40E-01
2.46E-01
2.68E-01
355
2.36E-01
2.31E-01
2.34E-01
2.40E-01
2.62E-01
356
2.38E-01
2.34E-01
2.37E-01
2.43E-01
2.65E-01
357
2.38E-01
2.34E-01
2.37E-01
2.43E-01
2.67E-01
358
2.36E-01
2.31E-01
2.34E-01
2.40E-01
2.62E-01
359
2.38E-01
2.33E-01
2.36E-01
2.42E-01
2.63E-01
360
2.40E-01
2.38E-01
2.38E-01
2.38E-01
2.37E-01
361
2.35E-01
2.33E-01
2.33E-01
2.33E-01
2.32E-01
Biased Statistics
Average Biased
2.39E-01
2.36E-01
2.39E-01
2.46E-01
2.70E-01
Std Dev Biased
5.48E-04
8.37E-04
8.37E-04
8.37E-04
4.92E-03
Ps90%/90% (+KTL) Biased
2.41E-01
2.38E-01
2.41E-01
2.48E-01
2.83E-01
Ps90%/90% (-KTL) Biased
2.38E-01
2.34E-01
2.37E-01
2.44E-01
2.56E-01
Un-Biased Statistics
Average Un-Biased
2.37E-01
2.33E-01
2.36E-01
2.42E-01
2.64E-01
Std Dev Un-Biased
1.10E-03
1.52E-03
1.52E-03
1.52E-03
2.17E-03
Ps90%/90% (+KTL) Un-Biased
2.40E-01
2.37E-01
2.40E-01
2.46E-01
2.70E-01
Ps90%/90% (-KTL) Un-Biased
2.34E-01
2.28E-01
2.31E-01
2.37E-01
2.58E-01
Specification MAX
3.50E-01
8.00E-01 1.00E+00 1.60E+00 1.60E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
174
TID Report
11-679 120209 R1.0
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Low 4 IL=1mA @ +5V (V)
1.80E+00
1.60E+00
1.40E+00
1.20E+00
1.00E+00
8.00E-01
6.00E-01
4.00E-01
2.00E-01
0.00E+00
0
50
100
150
200
Total Dose (krad(Si))
Figure 5.84. Plot of Output Voltage Low 4 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
175
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.84. Raw data for Output Voltage Low 4 IL=1mA @ +5V (V) versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
Total Dose (krad(Si))
Output Voltage Low 4 IL=1mA @ +5V (V)
Device
0
20
50
100
200
Date
12/9/2011
2/3/2012
2/3/2012
2/3/2012
2/3/2012
350
2.43E-01
2.38E-01
2.42E-01
2.49E-01
2.83E-01
351
2.45E-01
2.40E-01
2.44E-01
2.51E-01
2.83E-01
352
2.38E-01
2.35E-01
2.39E-01
2.47E-01
2.83E-01
353
2.43E-01
2.39E-01
2.43E-01
2.51E-01
2.83E-01
354
2.44E-01
2.36E-01
2.44E-01
2.52E-01
2.89E-01
355
2.41E-01
2.36E-01
2.40E-01
2.46E-01
2.74E-01
356
2.43E-01
2.39E-01
2.42E-01
2.50E-01
2.81E-01
357
2.44E-01
2.39E-01
2.42E-01
2.49E-01
2.79E-01
358
2.45E-01
2.40E-01
2.44E-01
2.51E-01
2.82E-01
359
2.45E-01
2.40E-01
2.44E-01
2.50E-01
2.80E-01
360
2.44E-01
2.42E-01
2.42E-01
2.42E-01
2.42E-01
361
2.44E-01
2.42E-01
2.42E-01
2.41E-01
2.41E-01
Biased Statistics
Average Biased
2.43E-01
2.38E-01
2.42E-01
2.50E-01
2.84E-01
Std Dev Biased
2.70E-03
2.07E-03
2.07E-03
2.00E-03
2.68E-03
Ps90%/90% (+KTL) Biased
2.50E-01
2.43E-01
2.48E-01
2.55E-01
2.92E-01
Ps90%/90% (-KTL) Biased
2.35E-01
2.32E-01
2.37E-01
2.45E-01
2.77E-01
Un-Biased Statistics
Average Un-Biased
2.44E-01
2.39E-01
2.42E-01
2.49E-01
2.79E-01
Std Dev Un-Biased
1.67E-03
1.64E-03
1.67E-03
1.92E-03
3.11E-03
Ps90%/90% (+KTL) Un-Biased
2.48E-01
2.43E-01
2.47E-01
2.54E-01
2.88E-01
Ps90%/90% (-KTL) Un-Biased
2.39E-01
2.34E-01
2.38E-01
2.44E-01
2.71E-01
Specification MAX
3.50E-01
8.00E-01 1.00E+00 1.60E+00 1.60E+00
Status
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
176
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
6.0. Summary / Conclusions
The total ionizing dose testing described in this final report was performed using the facilities at
Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose
(TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are
held in the base of the irradiator heavily shielded by lead, during the radiation exposures the rod is raised
by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in
this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s, determined by
the distance from the source.
The parametric data was obtained as "read and record" and all the raw data plus an attributes summary
are contained in this report as well as in a separate Excel file. The attributes data contains the average,
standard deviation and the average with the KTL values applied. The KTL value used in this work is
2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The
90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535
sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the
following criteria must be met for a device to pass the total ionizing dose test: following the radiation
exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units
irradiated without electrical bias and the KTL statistics are included in this report for reference only. If
any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet
specification limits, then the lot could be logged as a failure.
Based on this criterion the RH1014MJ Quad Precision Operational Amplifier (from the lot date code
identified on the first page of this test report) PASSED the total ionizing dose test to the maximum
tested dose level of 200krad(Si) with all parameters remaining within their datasheet specifications.
An ISO 9001:2008 and DSCC Certified Company
177
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix A: Photograph of Packing Label and a Sample Unit-Under-Test to Show Part
Traceability
An ISO 9001:2008 and DSCC Certified Company
178
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix B: Radiation Bias Connections and Absolute Maximum Ratings
TID Radiation Biased Conditions: Extracted from Linear Technology RH1014M datasheet.
Pin Function
Connection / Bias
OUT A To Pin 2 Via 10kΩ Resistor
1
-IN A
To Pin 1 Via 10kΩ Resistor
2
+IN A
8V Via 10kΩ Resistor
3
V+
+15V Decoupled to GND W/ 0.1µF
4
+IN B
8V Via 10kΩ Resistor
5
-IN B
To Pin 7 Via 10kΩ Resistor
6
OUT B To Pin 6 Via 10kΩ Resistor
7
OUT C To Pin 9 Via 10kΩ Resistor
8
-IN C
To Pin 8 Via 10kΩ Resistor
9
+IN C
8V Via 10kΩ Resistor
10
V-15V Decoupled to GND W/ 0.1µF
11
+IN D
8V Via 10kΩ Resistor
12
-IN D
To Pin 14 Via 10kΩ Resistor
13
OUT D To Pin 13 Via 10kΩ Resistor
14
Figure B.1. Irradiation bias circuit for the units to be irradiated under electrical bias. This figure was extracted
from Linear Technology RH1014M Quad Precision Operational Amplifier Datasheet.
An ISO 9001:2008 and DSCC Certified Company
179
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
TID Radiation Unbiased Conditions:
Pin Function Connection / Bias
OUT A GND
1
-IN A
2
GND
+IN A
3
GND
V+
4
GND
+IN B
5
GND
-IN B
6
GND
OUT B GND
7
OUT C GND
8
-IN C
9
GND
+IN C
10
GND
V11
GND
+IN D
12
GND
-IN D
13
GND
OUT D GND
14
Figure B.2. Package drawing (for reference only). This figure was extracted from Linear Technology RH1014M
Quad Precision Operational Amplifier Datasheet.
An ISO 9001:2008 and DSCC Certified Company
180
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix C: Electrical Test Parameters and Conditions
The expected ranges of values as well as the measurement conditions are taken from Linear Technology
RH1014M datasheet. All electrical tests for this device are performed on one of Aeroflex RAD's
LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that provides
parameter measurements for a variety of digital, analog and mixed signal products including voltage
regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System achieves
accuracy and sensitivity through the use of software self-calibration and an internal relay matrix with
separate family boards and custom personality adapter boards. The tester uses this relay matrix to
connect the required test circuits, select the appropriate voltage / current sources and establish the
needed measurement loops for all the tests performed. The measured parameters and test conditions are
shown in Table C.1.
A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The
precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020
for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table
C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between
tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90
KTL statistics were applied to the measured standard deviation to generate the final measurement range.
This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020
mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the
measurement resolution is limited by the internal DACs, which results in a measured standard deviation
of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC.
Note that the testing and statistics used in this document are based on an “analysis of variables”
technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p.
91 for a discussion of statistical treatments). Not all measured parameters are well suited to this
approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify
these parameters using an “attributes” approach.
An ISO 9001:2008 and DSCC Certified Company
181
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table C.1. Measured parameters and test conditions for the RH1014MJ Quad Precision Operational Amplifier.
Parameter
Test Conditions
Positive Supply Current (ICC+)
VS=±15V
Negative Supply Current (IEE-)
VS=±15V
Input Offset Voltage (VOS1-VOS4)
VS=±15V
Input Offset Current (IOS1-IOS4)
VS=±15V
+ Input Bias Current (IB+1-IB+4)
VS=±15V
- Input Bias Current (IB-1-IB-4)
VS=±15V
Common Mode Rejection Ratio (CMRR1-CMRR4)
VCM = 13.5V, –15V
Power Supply Rejection Ratio (PSRR1-PSRR4)
VS = ±10V to ±18V
Large Signal Voltage Gain (AVOL9-AVOL12)
VS=±15V, VO = ±10V, RL = 10kΩ
Positive Output Voltage Swing (VOUT+1-VOUT+4)
VS=±15V, RL= 10kΩ
Negative Output Voltage Swing (VOUT-1-VOUT-4)
VS=±15V, RL= 10kΩ
Positive Slew Rate (SlewRate+1 – SlewRate+4)
VS=±15V, RL= 10kΩ
Negative Slew Rate (SlewRate-1 – SlewRate-4)
VS=±15V, RL= 10kΩ
Positive Supply Current (ICC+2)
VS=+5V
Negative Supply Current (IEE-2)
VS=+5V
Input Offset Voltage (VOS5-VOS8)
VS=+5V
Input Offset Current (IOS5-IOS8)
VS=+5V
+ Input Bias Current (IB+5-IB+8)
VS=+5V
- Input Bias Current (IB-5-IB-8)
VS=+5V
Positive Output Voltage Swing (VOUT+5-VOUT+8)
VS=+5V, No Load
Positive Output Voltage Swing (VOUT+9-VOUT+12)
VS=+5V, RL= 600Ω
Output Voltage Low (VOUT-5-VOUT-8)
VS=+5V, No Load
Output Voltage Low (VOUT-9-VOUT-12)
VS=+5V, RL= 600Ω
Output Voltage Low (VOUT-13-VOUT-16)
VS=+5V, ISINK= 1mA
An ISO 9001:2008 and DSCC Certified Company
182
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH1014MJ
Quad Precision Operational Amplifier.
Parameter
Pre-Irradiation Specification
MIN
Positive Supply Current (ICC+)
MAX
Measurement
Precision/Resolution
2.20E-03 A
±3.26E-06 A
Negative Supply Current (IEE-)
-2.20E-03 A
±1.90E-06 A
Input Offset Voltage (VOS1-VOS4)
-3.00E-04 V
3.00E-04 V
±4.14E-06 V
Input Offset Current (IOS1-IOS4)
-1.00E-08 A
+1.00E-08 A
±9.59E-11 A
+ Input Bias Current (IB+1-IB+4)
-3.00E-08 A
3.00E-08 A
±4.80E-11 A
- Input Bias Current (IB-1-IB-4)
-3.00E-08 A
3.00E-08 A
±5.71E-11 A
Common Mode Rejection Ratio (CMRR1-CMRR4)
97 dB
±3.00E-01 dB
Power Supply Rejection Ratio (PSRR1-PSRR4)
100 dB
±6.11E+00 dB
1.20E+03 V/mV
±1.76E+03 V/mV
12.5 V
±9.97E-04 V
Large Signal Voltage Gain (AVOL9-AVOL12)
Positive Output Voltage Swing (VOUT+1-VOUT+4)
Negative Output Voltage Swing (VOUT-1-VOUT-4)
-12.5 V
Positive Slew Rate (SlewRate+1-SlewRate+4)
0.2 V/µs
Negative Slew Rate (SlewRate-1-SlewRate-4)
Positive Supply Current (ICC+2)
±1.07E-03 V
±140E-02 V/µs
-0.2 V/µs
±2.54E-02 V/µs
2.00E-03 A
±4.57E-06 A
Negative Supply Current (IEE-2)
-2.00E-03 A
±6.56E-06 A
Input Offset Voltage (VOS5-VOS8)
-4.50E-04 V
4.50E-04 V
±1.53E-06 V
Input Offset Current (IOS5-IOS8)
-1.00E-08 A
1.00E-08 A
±3.34E-11 A
+ Input Bias Current (IB+5-IB+8)
-5.00E-08 A
5.00E-08 A
±8.96E-11 A
- Input Bias Current (IB-5-IB-8)
-5.00E-08 A
5.00E-08 A
±8.71E-11 A
Positive Output Voltage Swing (VOUT+5-VOUT+8)
4.0 V
±1.07E-03 V
Positive Output Voltage Swing (VOUT+9-VOUT+12)
3.4 V
±8.71E-04 V
Output Voltage Low (VOUT-5-VOUT-8)
2.50E-02 V
±1.17E-04 V
Output Voltage Low (VOUT-9-VOUT-12)
1.00E-02 V
±1.38E-04 V
Output Voltage Low (VOUT-13-VOUT-16)
0.35 V
±6.53E-04 V
An ISO 9001:2008 and DSCC Certified Company
183
TID Report
11-679 120209 R1.0
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix D: List of Figures Used in the Results Section (Section 5)
5.1.
5.2.
5.3.
5.4.
5.5.
5.6.
5.7.
5.8.
5.9.
5.10.
5.11.
5.12.
5.13.
5.14.
5.15.
5.16.
5.17.
5.18.
5.19.
5.20.
5.21.
5.22.
5.23.
5.24.
5.25.
5.26.
5.27.
5.28.
5.29.
5.30.
5.31.
5.32.
5.33.
5.34.
5.35.
5.36.
5.37.
5.38.
5.39.
5.40.
Positive Supply Current @ +/-15V (A)
Negative Supply Current @ +/-15V (A)
Offset Voltage 1 @ +/-15V (V)
Offset Voltage 2 @ +/-15V (V)
Offset Voltage 3 @ +/-15V (V)
Offset Voltage 4 @ +/-15V (V)
Offset Current 1 @ +/-15V (A)
Offset Current 2 @ +/-15V (A)
Offset Current 3 @ +/-15V (A)
Offset Current 4 @ +/-15V (A)
Positive Bias Current 1 @ +/-15V (A)
Positive Bias Current 2 @ +/-15V (A)
Positive Bias Current 3 @ +/-15V (A)
Positive Bias Current 4 @ +/-15V (A)
Negative Bias Current 1 @ +/-15V (A)
Negative Bias Current 2 @ +/-15V (A)
Negative Bias Current 3 @ +/-15V (A)
Negative Bias Current 4 @ +/-15V (A)
Common Mode Rejection Ratio 1 (dB)
Common Mode Rejection Ratio 2 (dB)
Common Mode Rejection Ratio 3 (dB)
Common Mode Rejection Ratio 4 (dB)
Power Supply Rejection Ratio 1 (dB)
Power Supply Rejection Ratio 2 (dB)
Power Supply Rejection Ratio 3 (dB)
Power Supply Rejection Ratio 4 (dB)
Open Loop Gain 1 RL=10k VO=+/-10V (V/mV)
Open Loop Gain 2 RL=10k VO=+/-10V (V/mV)
Open Loop Gain 3 RL=10k VO=+/-10V (V/mV)
Open Loop Gain 4 RL=10k VO=+/-10V (V/mV)
Positive Output Voltage 1 @ +/-15V (V)
Positive Output Voltage 2 @ +/-15V (V)
Positive Output Voltage 3 @ +/-15V (V)
Positive Output Voltage 4 @ +/-15V (V)
Negative Output Voltage 1 @ +/-15V (V)
Negative Output Voltage 2 @ +/-15V (V)
Negative Output Voltage 3 @ +/-15V (V)
Negative Output Voltage 4 @ +/-15V (V)
Positive Slew Rate 1 @ +/-15V (V/us)
Positive Slew Rate 2 @ +/-15V (V/us)
An ISO 9001:2008 and DSCC Certified Company
184
TID Report
11-679 120209 R1.0
5.41.
5.42.
5.43.
5.44.
5.45.
5.46.
5.47.
5.48.
5.49.
5.50.
5.51.
5.52.
5.53.
5.54.
5.55.
5.56.
5.57.
5.58.
5.59.
5.60.
5.61.
5.62.
5.63.
5.64.
5.65.
5.66.
5.67.
5.68.
5.69.
5.70.
5.71.
5.72.
5.73.
5.74.
5.75.
5.76.
5.77.
5.78.
5.79.
5.80.
5.81.
5.82.
Positive Slew Rate 3 @ +/-15V (V/us)
Positive Slew Rate 4 @ +/-15V (V/us)
Negative Slew Rate 1 @ +/-15V (V/us)
Negative Slew Rate 2 @ +/-15V (V/us)
Negative Slew Rate 3 @ +/-15V (V/us)
Negative Slew Rate 4 @ +/-15V (V/us)
Positive Supply Current @ +5V (A)
Negative Supply Current @ +5V (A)
Offset Voltage 1 @ +5V (V)
Offset Voltage 2 @ +5V (V)
Offset Voltage 3 @ +5V (V)
Offset Voltage 4 @ +5V (V)
Offset Current 1 @ +5V (A)
Offset Current 2 @ +5V (A)
Offset Current 3 @ +5V (A)
Offset Current 4 @ +5V (A)
Positive Bias Current 1 @ +5V (A)
Positive Bias Current 2 @ +5V (A)
Positive Bias Current 3 @ +5V (A)
Positive Bias Current 4 @ +5V (A)
Negative Bias Current 1 @ +5V (A)
Negative Bias Current 2 @ +5V (A)
Negative Bias Current 3 @ +5V (A)
Negative Bias Current 4 @ +5V (A)
Positive Output Voltage 1 RL=open @ +5V (V)
Positive Output Voltage 2 RL=open @ +5V (V)
Positive Output Voltage 3 RL=open @ +5V (V)
Positive Output Voltage 4 RL=open @ +5V (V)
Positive Output Voltage 1 RL=600 @ +5V (V)
Positive Output Voltage 2 RL=600 @ +5V (V)
Positive Output Voltage 3 RL=600 @ +5V (V)
Positive Output Voltage 4 RL=600 @ +5V (V)
Output Voltage Low 1 RL=open @ +5V (V)
Output Voltage Low 2 RL=open @ +5V (V)
Output Voltage Low 3 RL=open @ +5V (V)
Output Voltage Low 4 RL=open @ +5V (V)
Output Voltage Low 1 RL=600 @ +5V (V)
Output Voltage Low 2 RL=600 @ +5V (V)
Output Voltage Low 3 RL=600 @ +5V (V)
Output Voltage Low 4 RL=600 @ +5V (V)
Output Voltage Low 1 IL=1mA @ +5V (V)
Output Voltage Low 2 IL=1mA @ +5V (V)
An ISO 9001:2008 and DSCC Certified Company
185
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
TID Report
11-679 120209 R1.0
5.83.
5.84.
Output Voltage Low 3 IL=1mA @ +5V (V)
Output Voltage Low 4 IL=1mA @ +5V (V)
An ISO 9001:2008 and DSCC Certified Company
186
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800