TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Radiation Lot Acceptance Testing (RLAT) of the RH1014MW Quad Precision Operational Amplifier for Linear Technology Customer: Linear Technology, PO# 61846L RAD Job Number: 12-085 Part Type Tested: RH1014MW Quad Precision Operational Amplifier, RH1014 DataSheet I.D. No.6611-1014 Revision G. Traceability Information: FAB Lot Number: W10905043.1, Wafer Number: 1, Assembly Lot Number: 645840, Date Code; 1142A. See photograph of unit under test in Appendix A. Quantity of Units: 11 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 1 unit for control. Serial numbers 107, 403, 408, 439 and 634 were biased during irradiation, serial numbers 720, 896, 921, 923 and 928 were unbiased during irradiation and serial number 940 was used as control. See Appendix B for the radiation bias connection table. Radiation and Electrical Test Increments: 50-300rad(Si)/s ionizing radiation with electrical test increments: pre-irradiation, 20krad(Si), 50krad(Si), 100krad(Si) and 200krad(Si). Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD Overtest and Post-Irradiation Anneal: No overtest. No anneal. Radiation Test Standard: MIL-STD-750E TM1019 and/or MIL-STD-883H TM1019 Condition A and Linear Technology RH1014 DataSheet I.D. No.66-11-1014 Revision G. Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS04, Calibration Date: 4/28/2011, Calibration Due: 4/28/2012. LTS2101 Family Board, Entity ID FB10. LTS0600 Test Fixture, Entity ID TF01. BGSS-970312 RH1014 DUT Board. Test Program: RH1014LT.SRC Facility and Radiation Source: Aeroflex RAD's Longmire Laboratories, Colorado Springs, CO. Gamma rays provided by JLSA 81-24 Co60 source. Dosimetry performed by Air Ionization Chamber (AIC) traceable to NIST. Aeroflex RAD's dosimetry has been audited by DSCC and Aeroflex RAD has been awarded Laboratory Suitability for MIL-STD-750 and MIL-STD-883 TM 1019. Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and MIL-STD-750. RLAT Result: PASSED the total ionizing dose test to the maximum tested dose level of 200krad(Si) with all parameters remaining within their datasheet specifications. An ISO 9001:2008 and DSCC Certified Company 1 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 1.0. Overview and Background It is well known that total dose ionizing radiation can cause parametric degradation and ultimately functional failure in electronic devices. The damage occurs via electron-hole pair production, transport and trapping in the dielectric and interface regions. In discrete devices the bulk of the damage is frequently manifested as a reduction in the gain and/or breakdown voltage of the device. The damage will usually anneal with time following the end of the radiation exposure. Due to this annealing, and to ensure a worst-case test condition MIL-STD-883 TM1019.8 calls out a dose rate of 50 to 300rad(Si)/s as Condition A and further specifies that the time from the end of an incremental radiation exposure and electrical testing shall be 1-hour or less and the total time from the end of one incremental irradiation to the beginning of the next incremental radiation step should be 2-hours or less. The work described in this report was performed to meet MIL-STD-883 TM1019.8 Condition A. 2.0. Radiation Test Apparatus The total ionizing dose testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose (TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead. During the radiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s, determined by the distance from the source. For high-dose rate experiments the bias boards are placed in a radial fashion equidistant from the raised Co-60 rods with the distance adjusted to provide the required dose rate. The irradiator calibration is maintained by Aeroflex RAD Longmire Laboratories using air ionization chamber (AIC) equipment calibrated with traceability to the National Institute of Standards and Technology (NIST). Figure 2.1 shows a photograph of the JLSA 81-24 Co-60 irradiator at Aeroflex RAD's Longmire Laboratory facility. Aeroflex RAD is currently certified by the Defense Supply Center Columbus (DSCC) for Laboratory Suitability under MIL STD 750 and MIL-STD-883. Additional details regarding Aeroflex RAD dosimetry for TM1019 Condition A testing are available in Aeroflex RAD's report to DSCC entitled: "Dose Rate Mapping of the J.L. Shepherd and Associates Model 81 Irradiator Installed by Radiation Assured Devices". An ISO 9001:2008 and DSCC Certified Company 2 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Figure 2.1. Aeroflex RAD's high dose rate Co-60 irradiator. The dose rate is obtained by positioning the deviceunder-test at a fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately 120rad(Si)/s close to the rods down to 1rad(Si)/s at a distance of approximately 2-feet. An ISO 9001:2008 and DSCC Certified Company 3 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 3.0. Radiation Test Conditions The RH1014MW Quad Precision Operational Amplifier described in this final report were irradiated using a split 15V supply and with all pins tied to ground, that is biased and unbiased. See the TID Bias Table in Appendix B for the full bias circuits. In our opinion, this bias circuit satisfies the requirements of MIL-STD-883H TM1019.8 Section 3.9.3 Bias and Loading Conditions which states "The bias applied to the test devices shall be selected to produce the greatest radiation induced damage or the worst-case damage for the intended application, if known. While maximum voltage is often worst case some bipolar linear device parameters (e.g. input bias current or maximum output load current) exhibit more degradation with 0 V bias." The devices were irradiated to a maximum total ionizing dose level of 200krad(Si) with incremental readings at 20krad(Si), 50krad(Si) and 100krad(Si). Electrical testing occurred within one hour following the end of each irradiation segment. For intermediate irradiations, the parts were tested and returned to total dose exposure within two hours from the end of the previous radiation increment. The TID bias board was positioned in the Co-60 cell to provide the required minimum of 50rad(Si)/s and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019.8 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1) initially, (2) when the source is changed, or (3) when the orientation or configuration of the source, container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g., a TLD) in the device-irradiation container at the approximate test-device position. If it can be demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors due to dose enhancement, the Pb/Al container may be omitted." The final dose rate within the high dose rate lead-aluminum enclosure was determined using calibration calculations based on air ionization chamber (AIC) dosimetry performed just prior to beginning the total dose irradiations. The final dose rate for this work was 51.53rad(Si)/s with a precision of ±5%. An ISO 9001:2008 and DSCC Certified Company 4 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 4.0. Tested Parameters During the total ionizing dose characterization testing the following electrical parameters were measured pre- and post-irradiation: 1. Positive Supply Current @ +/-15V (A) 2. Negative Supply Current @ +/-15V (A) 3. Offset Voltage 1 @ +/-15V (V) 4. Offset Voltage 2 @ +/-15V (V) 5. Offset Voltage 3 @ +/-15V (V) 6. Offset Voltage 4 @ +/-15V (V) 7. Offset Current 1 @ +/-15V (A) 8. Offset Current 2 @ +/-15V (A) 9. Offset Current 3 @ +/-15V (A) 10. Offset Current 4 @ +/-15V (A) 11. Positive Bias Current 1 @ +/-15V (A) 12. Positive Bias Current 2 @ +/-15V (A) 13. Positive Bias Current 3 @ +/-15V (A) 14. Positive Bias Current 4 @ +/-15V (A) 15. Negative Bias Current 1 @ +/-15V (A) 16. Negative Bias Current 2 @ +/-15V (A) 17. Negative Bias Current 3 @ +/-15V (A) 18. Negative Bias Current 4 @ +/-15V (A) 19. Common Mode Rejection Ratio 1 (dB) 20. Common Mode Rejection Ratio 2 (dB) 21. Common Mode Rejection Ratio 3 (dB) 22. Common Mode Rejection Ratio 4 (dB) 23. Power Supply Rejection Ratio 1 (dB) 24. Power Supply Rejection Ratio 2 (dB) 25. Power Supply Rejection Ratio 3 (dB) 26. Power Supply Rejection Ratio 4 (dB) 27. Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) 28. Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) 29. Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) 30. Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) 31. Positive Output Voltage 1 @ +/-15V (V) 32. Positive Output Voltage 2 @ +/-15V (V) 33. Positive Output Voltage 3 @ +/-15V (V) 34. Positive Output Voltage 4 @ +/-15V (V) 35. Negative Output Voltage 1 @ +/-15V (V) 36. Negative Output Voltage 2 @ +/-15V (V) 37. Negative Output Voltage 3 @ +/-15V (V) An ISO 9001:2008 and DSCC Certified Company 5 TID Report 12-085 120320 R1.1 38. Negative Output Voltage 4 @ +/-15V (V) 39. Positive Slew Rate 1 @ +/-15V (V/us) 40. Positive Slew Rate 2 @ +/-15V (V/us) 41. Positive Slew Rate 3 @ +/-15V (V/us) 42. Positive Slew Rate 4 @ +/-15V (V/us) 43. Negative Slew Rate 1 @ +/-15V (V/us) 44. Negative Slew Rate 2 @ +/-15V (V/us) 45. Negative Slew Rate 3 @ +/-15V (V/us) 46. Negative Slew Rate 4 @ +/-15V (V/us) 47. Positive Supply Current @ +5V (A) 48. Negative Supply Current @ +5V (A) 49. Offset Voltage 1 @ +5V (V) 50. Offset Voltage 2 @ +5V (V) 51. Offset Voltage 3 @ +5V (V) 52. Offset Voltage 4 @ +5V (V) 53. Offset Current 1 @ +5V (A) 54. Offset Current 2 @ +5V (A) 55. Offset Current 3 @ +5V (A) 56. Offset Current 4 @ +5V (A) 57. Positive Bias Current 1 @ +5V (A) 58. Positive Bias Current 2 @ +5V (A) 59. Positive Bias Current 3 @ +5V (A) 60. Positive Bias Current 4 @ +5V (A) 61. Negative Bias Current 1 @ +5V (A) 62. Negative Bias Current 2 @ +5V (A) 63. Negative Bias Current 3 @ +5V (A) 64. Negative Bias Current 4 @ +5V (A) 65. Positive Output Voltage 1 RL=open @ +5V (V) 66. Positive Output Voltage 2 RL=open @ +5V (V) 67. Positive Output Voltage 3 RL=open @ +5V (V) 68. Positive Output Voltage 4 RL=open @ +5V (V) 69. Positive Output Voltage 1 RL=600 @ +5V (V) 70. Positive Output Voltage 2 RL=600 @ +5V (V) 71. Positive Output Voltage 3 RL=600 @ +5V (V) 72. Positive Output Voltage 4 RL=600 @ +5V (V) 73. Output Voltage Low 1 RL=open @ +5V (V) 74. Output Voltage Low 2 RL=open @ +5V (V) 75. Output Voltage Low 3 RL=open @ +5V (V) 76. Output Voltage Low 4 RL=open @ +5V (V) 77. Output Voltage Low 1 RL=600 @ +5V (V) 78. Output Voltage Low 2 RL=600 @ +5V (V) 79. Output Voltage Low 3 RL=600 @ +5V (V) An ISO 9001:2008 and DSCC Certified Company 6 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 80. Output Voltage Low 4 RL=600 @ +5V (V) 81. Output Voltage Low 1 IL=1mA @ +5V (V) 82. Output Voltage Low 2 IL=1mA @ +5V (V) 83. Output Voltage Low 3 IL=1mA @ +5V (V) 84. Output Voltage Low 4 IL=1mA @ +5V (V) Appendix C details the measured parameters, test conditions, pre-irradiation specification and measurement resolution for each of the measurements. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the total ionizing dose test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. An ISO 9001:2008 and DSCC Certified Company 7 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 5.0. Total Ionizing Dose Test Results Based on this criterion the RH1014MW Quad Precision Operational Amplifier (from the lot traceability information provided on the first page of this test report) PASSED the total ionizing dose test to the maximum tested dose level of 200krad(Si) with all parameters remaining within their datasheet specifications. Figures 5.1 through 5.84 show plots of all the measured parameters versus total ionizing dose while Tables 5.1 - 5.84 show the corresponding raw data for each of these parameters. In the data plots the solid diamonds are the average of the measured data points for the sample irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the units irradiated with all pins tied to ground. The black lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. The control units, as expected, show no significant changes to any of the parameters. Therefore we can conclude that the electrical testing remained in control throughout the duration of the tests and the observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section to facilitate the location of a particular parameter. An ISO 9001:2008 and DSCC Certified Company 8 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Positive Supply Current @ +/-15V (A) 2.50E-03 2.00E-03 1.50E-03 1.00E-03 5.00E-04 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.1. Plot of Positive Supply Current @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 9 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.1. Raw data for Positive Supply Current @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Supply Current @ +/-15V (A) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 1.59E-03 1.62E-03 1.60E-03 1.56E-03 1.36E-03 403 1.62E-03 1.65E-03 1.63E-03 1.57E-03 1.38E-03 408 1.67E-03 1.69E-03 1.66E-03 1.60E-03 1.41E-03 439 1.61E-03 1.64E-03 1.61E-03 1.55E-03 1.37E-03 634 1.71E-03 1.71E-03 1.69E-03 1.62E-03 1.43E-03 720 1.64E-03 1.70E-03 1.67E-03 1.60E-03 1.43E-03 896 1.64E-03 1.69E-03 1.66E-03 1.60E-03 1.40E-03 921 1.69E-03 1.70E-03 1.67E-03 1.61E-03 1.41E-03 923 1.61E-03 1.67E-03 1.64E-03 1.57E-03 1.38E-03 928 1.67E-03 1.71E-03 1.67E-03 1.61E-03 1.41E-03 940 1.63E-03 1.63E-03 1.63E-03 1.63E-03 1.63E-03 Biased Statistics Average Biased 1.64E-03 1.66E-03 1.64E-03 1.58E-03 1.39E-03 Std Dev Biased 4.87E-05 3.77E-05 3.61E-05 3.06E-05 2.95E-05 Ps90%/90% (+KTL) Biased 1.77E-03 1.77E-03 1.74E-03 1.66E-03 1.47E-03 Ps90%/90% (-KTL) Biased 1.51E-03 1.56E-03 1.54E-03 1.50E-03 1.31E-03 Un-Biased Statistics Average Un-Biased 1.65E-03 1.69E-03 1.66E-03 1.60E-03 1.41E-03 Std Dev Un-Biased 3.13E-05 1.48E-05 1.30E-05 1.40E-05 1.67E-05 Ps90%/90% (+KTL) Un-Biased 1.73E-03 1.73E-03 1.70E-03 1.64E-03 1.45E-03 Ps90%/90% (-KTL) Un-Biased 1.56E-03 1.65E-03 1.63E-03 1.56E-03 1.36E-03 Specification MAX 2.20E-03 2.20E-03 2.20E-03 2.20E-03 2.20E-03 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 10 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Negative Supply Current @ +/-15V (A) 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 -2.00E-03 -2.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.2. Plot of Negative Supply Current @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 11 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.2. Raw data for Negative Supply Current @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Supply Current @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 -1.60E-03 -1.62E-03 -1.67E-03 -1.61E-03 -1.71E-03 -1.64E-03 -1.64E-03 -1.69E-03 -1.61E-03 -1.67E-03 -1.63E-03 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -1.63E-03 -1.60E-03 -1.56E-03 -1.65E-03 -1.63E-03 -1.57E-03 -1.69E-03 -1.66E-03 -1.60E-03 -1.64E-03 -1.61E-03 -1.55E-03 -1.71E-03 -1.69E-03 -1.62E-03 -1.69E-03 -1.67E-03 -1.60E-03 -1.69E-03 -1.67E-03 -1.60E-03 -1.70E-03 -1.67E-03 -1.61E-03 -1.67E-03 -1.64E-03 -1.57E-03 -1.71E-03 -1.68E-03 -1.61E-03 -1.63E-03 -1.63E-03 -1.63E-03 2/16/2012 200 -1.36E-03 -1.38E-03 -1.41E-03 -1.37E-03 -1.43E-03 -1.43E-03 -1.41E-03 -1.42E-03 -1.38E-03 -1.41E-03 -1.63E-03 -1.64E-03 -1.66E-03 -1.64E-03 -1.58E-03 -1.39E-03 4.85E-05 3.81E-05 3.74E-05 3.06E-05 2.98E-05 -1.51E-03 -1.56E-03 -1.54E-03 -1.50E-03 -1.31E-03 -1.77E-03 -1.77E-03 -1.74E-03 -1.66E-03 -1.47E-03 -1.65E-03 3.12E-05 -1.56E-03 -1.73E-03 -2.20E-03 PASS -1.69E-03 1.50E-05 -1.65E-03 -1.73E-03 -2.20E-03 PASS -1.67E-03 1.46E-05 -1.63E-03 -1.71E-03 -2.20E-03 PASS An ISO 9001:2008 and DSCC Certified Company 12 -1.60E-03 1.43E-05 -1.56E-03 -1.64E-03 -2.20E-03 PASS -1.41E-03 1.76E-05 -1.36E-03 -1.46E-03 -2.20E-03 PASS TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 1 @ +/-15V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.3. Plot of Offset Voltage 1 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 13 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.3. Raw data for Offset Voltage 1 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Voltage 1 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -5.34E-05 -5.42E-05 3.46E-05 -4.00E-05 7.64E-05 -2.41E-05 4.88E-06 -2.40E-05 -1.32E-05 4.75E-05 -2.17E-05 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 2/16/2012 20 50 100 200 -4.47E-05 -2.66E-05 -2.36E-06 4.68E-05 -5.04E-05 -3.17E-05 -9.97E-06 4.45E-05 3.60E-05 4.75E-05 5.96E-05 8.71E-05 -3.60E-05 -1.75E-05 1.26E-06 4.88E-05 7.53E-05 8.61E-05 1.05E-04 1.43E-04 -1.77E-05 1.51E-06 3.11E-05 1.11E-04 3.92E-06 1.12E-05 2.72E-05 8.03E-05 -6.32E-05 -2.76E-05 1.82E-05 1.16E-04 -1.18E-05 -7.90E-07 2.29E-05 8.06E-05 4.62E-05 5.51E-05 7.04E-05 1.13E-04 -2.24E-05 -2.30E-05 -2.28E-05 -2.12E-05 -7.34E-06 -3.98E-06 1.16E-05 3.07E-05 7.40E-05 5.95E-05 5.64E-05 5.25E-05 5.00E-05 4.24E-05 1.56E-04 1.51E-04 1.56E-04 1.68E-04 1.90E-04 -1.70E-04 -1.59E-04 -1.32E-04 -1.06E-04 -4.21E-05 -1.78E-06 3.00E-05 8.04E-05 -8.40E-05 -3.00E-04 PASS 3.00E-04 PASS -8.52E-06 3.95E-05 9.97E-05 -1.17E-04 -4.50E-04 PASS 4.50E-04 PASS 7.88E-06 3.01E-05 9.03E-05 -7.46E-05 -6.00E-04 PASS 6.00E-04 PASS 3.40E-05 1.00E-04 2.10E-05 1.81E-05 9.14E-05 1.50E-04 -2.35E-05 5.05E-05 -7.50E-04 -9.00E-04 PASS PASS 7.50E-04 9.00E-04 PASS PASS An ISO 9001:2008 and DSCC Certified Company 14 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 2 @ +/-15V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.4. Plot of Offset Voltage 2 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 15 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.4. Raw data for Offset Voltage 2 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Voltage 2 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 3.60E-05 -2.92E-05 -3.01E-05 8.14E-06 -5.90E-05 -2.96E-06 -3.19E-05 9.63E-05 2.48E-05 -2.34E-05 4.56E-05 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 2/16/2012 20 50 100 200 3.63E-05 5.56E-05 8.18E-05 1.39E-04 -2.68E-05 -1.21E-05 7.66E-06 6.47E-05 -2.84E-05 -1.87E-05 -1.88E-06 3.60E-05 1.32E-05 3.11E-05 5.95E-05 1.23E-04 -5.17E-05 -3.46E-05 -1.81E-05 2.54E-05 5.40E-07 1.37E-05 4.41E-05 1.06E-04 -2.94E-05 -2.06E-05 -6.34E-06 4.32E-05 9.95E-05 1.06E-04 1.16E-04 1.61E-04 2.71E-05 3.95E-05 6.60E-05 1.24E-04 -2.52E-05 -1.82E-05 -2.24E-06 5.27E-05 4.51E-05 4.58E-05 4.51E-05 4.52E-05 -1.48E-05 -1.15E-05 4.26E-06 2.58E-05 7.76E-05 3.71E-05 3.55E-05 3.76E-05 4.27E-05 5.12E-05 8.69E-05 8.58E-05 1.07E-04 1.43E-04 2.18E-04 -1.17E-04 -1.09E-04 -9.89E-05 -9.12E-05 -6.26E-05 1.26E-05 5.16E-05 1.54E-04 -1.29E-04 -3.00E-04 PASS 3.00E-04 PASS 1.45E-05 5.26E-05 1.59E-04 -1.30E-04 -4.50E-04 PASS 4.50E-04 PASS 2.42E-05 5.22E-05 1.67E-04 -1.19E-04 -6.00E-04 PASS 6.00E-04 PASS 4.34E-05 5.07E-05 1.83E-04 -9.57E-05 -7.50E-04 PASS 7.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 16 9.73E-05 4.93E-05 2.32E-04 -3.78E-05 -9.00E-04 PASS 9.00E-04 PASS TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 3 @ +/-15V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.5. Plot of Offset Voltage 3 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 17 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.5. Raw data for Offset Voltage 3 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Voltage 3 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -1.03E-05 -2.02E-05 4.22E-05 -3.52E-05 -5.22E-05 2.23E-05 5.97E-06 -3.83E-05 -4.29E-06 -2.99E-05 2.03E-05 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 2/16/2012 20 50 100 200 1.62E-06 1.37E-05 3.85E-05 1.08E-04 -1.15E-05 -1.03E-06 1.42E-05 5.17E-05 4.67E-05 5.92E-05 7.80E-05 1.19E-04 -3.03E-05 -1.93E-05 5.40E-07 4.22E-05 -4.09E-05 -3.22E-05 -1.34E-05 2.22E-05 2.26E-05 3.79E-05 6.44E-05 1.36E-04 7.66E-06 1.58E-05 2.90E-05 6.86E-05 -3.50E-05 -3.06E-05 -1.69E-05 1.76E-05 -3.57E-06 3.20E-06 2.34E-05 7.36E-05 -3.13E-05 -2.78E-05 -7.07E-06 2.77E-05 1.97E-05 2.00E-05 2.00E-05 2.03E-05 -1.52E-05 -6.88E-06 4.09E-06 2.36E-05 6.85E-05 3.58E-05 3.41E-05 3.54E-05 3.60E-05 4.24E-05 8.29E-05 8.67E-05 1.01E-04 1.22E-04 1.85E-04 -1.13E-04 -1.00E-04 -9.30E-05 -7.50E-05 -4.78E-05 -8.85E-06 2.51E-05 6.00E-05 -7.77E-05 -3.00E-04 PASS 3.00E-04 PASS -7.92E-06 2.49E-05 6.03E-05 -7.61E-05 -4.50E-04 PASS 4.50E-04 PASS -3.28E-07 2.92E-05 7.96E-05 -8.03E-05 -6.00E-04 PASS 6.00E-04 PASS 1.86E-05 3.22E-05 1.07E-04 -6.97E-05 -7.50E-04 PASS 7.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 18 6.46E-05 4.67E-05 1.93E-04 -6.34E-05 -9.00E-04 PASS 9.00E-04 PASS TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 4 @ +/-15V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.6. Plot of Offset Voltage 4 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 19 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.6. Raw data for Offset Voltage 4 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Voltage 4 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -5.56E-05 -2.64E-05 2.81E-05 1.67E-05 2.65E-05 4.16E-05 4.64E-05 -1.66E-05 1.18E-05 5.63E-05 7.49E-05 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 2/16/2012 20 50 100 200 -5.20E-05 -3.97E-05 -2.26E-05 2.71E-05 -2.48E-05 -1.09E-05 9.59E-06 5.87E-05 3.05E-05 4.15E-05 5.76E-05 8.77E-05 2.20E-05 4.09E-05 6.13E-05 1.21E-04 3.14E-05 4.40E-05 6.09E-05 9.27E-05 4.18E-05 5.70E-05 8.23E-05 1.57E-04 2.43E-05 5.99E-05 9.16E-05 1.62E-04 -1.58E-05 -1.15E-06 2.35E-05 9.10E-05 1.51E-05 2.60E-05 4.73E-05 1.14E-04 5.99E-05 7.25E-05 8.65E-05 1.51E-04 7.39E-05 7.42E-05 7.42E-05 7.42E-05 -2.14E-06 1.43E-06 1.51E-05 3.34E-05 7.74E-05 3.72E-05 3.78E-05 3.83E-05 3.82E-05 3.57E-05 9.98E-05 1.05E-04 1.20E-04 1.38E-04 1.75E-04 -1.04E-04 -1.02E-04 -8.99E-05 -7.13E-05 -2.06E-05 2.79E-05 2.99E-05 1.10E-04 -5.41E-05 -3.00E-04 PASS 3.00E-04 PASS 2.51E-05 2.86E-05 1.03E-04 -5.32E-05 -4.50E-04 PASS 4.50E-04 PASS 4.29E-05 3.00E-05 1.25E-04 -3.93E-05 -6.00E-04 PASS 6.00E-04 PASS 6.62E-05 1.35E-04 2.96E-05 3.10E-05 1.47E-04 2.20E-04 -1.49E-05 4.98E-05 -7.50E-04 -9.00E-04 PASS PASS 7.50E-04 9.00E-04 PASS PASS An ISO 9001:2008 and DSCC Certified Company 20 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Offset Current 1 @ +/-15V (A) 3.00E-08 2.00E-08 1.00E-08 0.00E+00 -1.00E-08 -2.00E-08 -3.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.7. Plot of Offset Current 1 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 21 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.7. Raw data for Offset Current 1 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Current 1 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 5.30E-11 7.10E-11 5.30E-11 2.40E-11 2.30E-11 3.30E-11 -7.90E-11 4.00E-12 -2.10E-11 -1.60E-11 3.40E-11 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 2.20E-11 -9.60E-11 4.10E-11 9.00E-11 1.58E-10 1.17E-10 0.00E+00 2.60E-11 1.33E-10 3.50E-11 7.40E-11 1.25E-10 1.30E-11 1.37E-10 4.40E-11 3.40E-11 7.00E-12 7.20E-11 -7.30E-11 -2.36E-10 -6.64E-10 -1.90E-11 -4.80E-11 -5.80E-11 -8.20E-11 -2.18E-10 -1.84E-10 -3.50E-11 -1.65E-10 -4.85E-10 3.70E-11 4.50E-11 2.90E-11 2/16/2012 200 1.56E-10 9.80E-11 6.78E-10 1.66E-10 -3.00E-10 -9.80E-11 -1.59E-09 1.10E-11 -4.01E-10 -1.32E-09 4.30E-11 4.48E-11 3.20E-11 5.98E-11 9.20E-11 1.60E-10 2.08E-11 3.48E-11 1.02E-10 4.56E-11 3.48E-10 1.02E-10 1.28E-10 3.38E-10 2.17E-10 1.11E-09 -1.22E-11 -6.36E-11 -2.19E-10 -3.29E-11 -7.94E-10 -1.58E-11 4.12E-11 9.72E-11 -1.29E-10 -1.00E-08 PASS 1.00E-08 PASS -3.50E-11 4.66E-11 9.27E-11 -1.63E-10 -1.00E-08 PASS 1.00E-08 PASS -1.32E-10 1.07E-10 1.61E-10 -4.25E-10 -1.50E-08 PASS 1.50E-08 PASS -2.64E-10 3.04E-10 5.71E-10 -1.10E-09 -2.00E-08 PASS 2.00E-08 PASS An ISO 9001:2008 and DSCC Certified Company 22 -6.79E-10 7.29E-10 1.32E-09 -2.68E-09 -2.50E-08 PASS 2.50E-08 PASS TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Offset Current 2 @ +/-15V (A) 3.00E-08 2.00E-08 1.00E-08 0.00E+00 -1.00E-08 -2.00E-08 -3.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.8. Plot of Offset Current 2 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 23 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.8. Raw data for Offset Current 2 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Current 2 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -1.10E-11 -1.20E-11 -4.20E-11 1.70E-11 -4.00E-12 8.00E-12 1.00E-11 1.00E-11 -2.00E-12 -8.60E-11 -3.90E-11 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -3.30E-11 -3.90E-11 -1.24E-10 -3.50E-11 3.30E-11 1.69E-10 1.06E-10 7.60E-11 7.60E-11 0.00E+00 -4.90E-11 -8.40E-11 8.10E-11 2.10E-11 -4.30E-11 3.40E-11 4.00E-11 0.00E+00 1.40E-11 -8.10E-11 -4.27E-10 -1.20E-11 -5.70E-11 -1.43E-10 3.00E-11 -1.32E-10 1.60E-11 -5.40E-11 -1.35E-10 -1.90E-10 -4.50E-11 -6.00E-11 -3.40E-11 2/16/2012 200 2.40E-11 1.63E-10 1.81E-10 -3.96E-10 -2.65E-10 2.79E-10 -1.74E-09 -1.58E-09 -4.63E-10 -5.04E-10 -3.40E-11 -1.04E-11 2.38E-11 8.40E-12 -1.20E-12 -5.86E-11 2.12E-11 6.57E-11 5.21E-11 1.21E-10 2.60E-10 4.77E-11 2.04E-10 1.51E-10 3.31E-10 6.53E-10 -6.85E-11 -1.56E-10 -1.35E-10 -3.33E-10 -7.71E-10 -1.20E-11 4.17E-11 1.02E-10 -1.26E-10 -1.00E-08 PASS 1.00E-08 PASS 2.40E-12 3.63E-11 1.02E-10 -9.73E-11 -1.00E-08 PASS 1.00E-08 PASS -7.30E-11 7.14E-11 1.23E-10 -2.69E-10 -1.50E-08 PASS 1.50E-08 PASS -1.49E-10 1.79E-10 3.43E-10 -6.40E-10 -2.00E-08 PASS 2.00E-08 PASS An ISO 9001:2008 and DSCC Certified Company 24 -8.03E-10 8.47E-10 1.52E-09 -3.12E-09 -2.50E-08 PASS 2.50E-08 PASS TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Offset Current 3 @ +/-15V (A) 3.00E-08 2.00E-08 1.00E-08 0.00E+00 -1.00E-08 -2.00E-08 -3.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.9. Plot of Offset Current 3 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 25 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.9. Raw data for Offset Current 3 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Current 3 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -9.00E-11 6.80E-11 3.50E-11 4.80E-11 -2.70E-11 -9.80E-11 -3.00E-12 -1.72E-10 -3.30E-11 -1.10E-11 -5.10E-11 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -1.47E-10 -1.21E-10 -1.48E-10 1.19E-10 1.13E-10 2.08E-10 -4.00E-12 -2.20E-11 -3.80E-11 1.20E-11 -5.50E-11 -8.60E-11 3.90E-11 -7.40E-11 -1.60E-10 -4.60E-11 1.90E-11 1.00E-11 -3.20E-11 -9.30E-11 -3.70E-10 -3.11E-10 -3.53E-10 -5.96E-10 -3.40E-11 -6.30E-11 -1.50E-11 7.10E-11 4.70E-11 3.04E-10 -3.80E-11 -5.70E-11 -3.80E-11 2/16/2012 200 -2.10E-11 5.08E-10 4.25E-10 -9.40E-11 -2.20E-10 -6.90E-11 -2.06E-09 -1.71E-09 -1.09E-10 1.28E-10 -5.20E-11 6.80E-12 3.80E-12 -3.18E-11 -4.48E-11 1.20E-10 6.47E-11 9.67E-11 8.85E-11 1.50E-10 3.26E-10 1.84E-10 2.69E-10 2.11E-10 3.66E-10 1.01E-09 -1.71E-10 -2.61E-10 -2.75E-10 -4.55E-10 -7.74E-10 -6.34E-11 7.13E-11 1.32E-10 -2.59E-10 -1.00E-08 PASS 1.00E-08 PASS -7.04E-11 1.43E-10 3.20E-10 -4.61E-10 -1.00E-08 PASS 1.00E-08 PASS -8.86E-11 1.59E-10 3.46E-10 -5.23E-10 -1.50E-08 PASS 1.50E-08 PASS -1.33E-10 3.52E-10 8.32E-10 -1.10E-09 -2.00E-08 PASS 2.00E-08 PASS An ISO 9001:2008 and DSCC Certified Company 26 -7.64E-10 1.03E-09 2.07E-09 -3.60E-09 -2.50E-08 PASS 2.50E-08 PASS TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Offset Current 4 @ +/-15V (A) 3.00E-08 2.00E-08 1.00E-08 0.00E+00 -1.00E-08 -2.00E-08 -3.00E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.10. Plot of Offset Current 4 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 27 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.10. Raw data for Offset Current 4 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Current 4 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -2.50E-11 4.20E-11 2.10E-11 -3.20E-11 -3.00E-12 -6.90E-11 4.00E-11 -8.00E-11 -1.80E-11 -1.11E-10 -9.90E-11 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -8.90E-11 -5.10E-11 -7.00E-11 9.50E-11 1.00E-10 9.40E-11 1.02E-10 1.40E-10 2.38E-10 -6.20E-11 -6.80E-11 8.00E-12 2.60E-11 -1.27E-10 -1.87E-10 -5.20E-11 3.20E-11 -1.33E-10 -7.50E-11 -2.01E-10 -6.27E-10 -6.90E-11 -7.00E-12 -2.35E-10 -1.07E-10 -1.09E-10 -1.86E-10 -1.82E-10 -3.13E-10 -3.45E-10 -9.30E-11 -1.03E-10 -1.02E-10 2/16/2012 200 -2.15E-10 8.80E-11 6.51E-10 -1.90E-11 -6.06E-10 -9.40E-11 -1.75E-09 1.10E-10 -4.53E-10 -1.32E-09 -6.20E-11 6.00E-13 1.44E-11 -1.20E-12 1.66E-11 -2.02E-11 3.11E-11 8.78E-11 1.15E-10 1.61E-10 4.59E-10 8.58E-11 2.55E-10 3.14E-10 4.59E-10 1.24E-09 -8.46E-11 -2.26E-10 -3.17E-10 -4.26E-10 -1.28E-09 -4.76E-11 5.93E-11 1.15E-10 -2.10E-10 -1.00E-08 PASS 1.00E-08 PASS -9.70E-11 5.15E-11 4.43E-11 -2.38E-10 -1.00E-08 PASS 1.00E-08 PASS -1.20E-10 1.41E-10 2.68E-10 -5.07E-10 -1.50E-08 PASS 1.50E-08 PASS -3.05E-10 1.96E-10 2.33E-10 -8.43E-10 -2.00E-08 PASS 2.00E-08 PASS An ISO 9001:2008 and DSCC Certified Company 28 -7.01E-10 8.02E-10 1.50E-09 -2.90E-09 -2.50E-08 PASS 2.50E-08 PASS TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 1 @ +/-15V (A) 3.00E-07 2.00E-07 1.00E-07 0.00E+00 -1.00E-07 -2.00E-07 -3.00E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.11. Plot of Positive Bias Current 1 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 29 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.11. Raw data for Positive Bias Current 1 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Bias Current 1 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.02E-08 1.29E-08 1.85E-08 2.59E-08 4.36E-08 1.05E-08 1.30E-08 1.84E-08 2.58E-08 4.34E-08 9.56E-09 1.23E-08 1.78E-08 2.49E-08 4.14E-08 1.11E-08 1.42E-08 2.03E-08 2.80E-08 4.63E-08 9.97E-09 1.27E-08 1.82E-08 2.55E-08 4.33E-08 9.93E-09 1.21E-08 1.69E-08 2.30E-08 3.79E-08 1.01E-08 1.26E-08 1.81E-08 2.53E-08 4.23E-08 1.02E-08 1.26E-08 1.76E-08 2.39E-08 3.96E-08 1.00E-08 1.28E-08 1.78E-08 2.45E-08 4.12E-08 1.02E-08 1.29E-08 1.83E-08 2.54E-08 4.29E-08 9.81E-09 9.79E-09 9.77E-09 9.81E-09 9.81E-09 1.03E-08 5.65E-10 1.18E-08 8.72E-09 1.30E-08 7.26E-10 1.50E-08 1.10E-08 1.87E-08 9.69E-10 2.13E-08 1.60E-08 2.60E-08 1.17E-09 2.92E-08 2.28E-08 4.36E-08 1.77E-09 4.84E-08 3.87E-08 1.01E-08 1.26E-08 1.77E-08 2.44E-08 4.08E-08 1.38E-10 3.03E-10 5.43E-10 9.99E-10 2.05E-09 1.05E-08 1.34E-08 1.92E-08 2.72E-08 4.64E-08 9.73E-09 1.18E-08 1.63E-08 2.17E-08 3.52E-08 -3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07 PASS PASS PASS PASS PASS 3.00E-08 7.50E-08 1.00E-07 1.75E-07 2.50E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 30 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 2 @ +/-15V (A) 3.00E-07 2.00E-07 1.00E-07 0.00E+00 -1.00E-07 -2.00E-07 -3.00E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.12. Plot of Positive Bias Current 2 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 31 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.12. Raw data for Positive Bias Current 2 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Bias Current 2 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.12E-08 1.38E-08 1.96E-08 2.69E-08 4.54E-08 1.09E-08 1.35E-08 1.91E-08 2.65E-08 4.45E-08 9.85E-09 1.25E-08 1.80E-08 2.47E-08 4.13E-08 1.13E-08 1.45E-08 2.06E-08 2.81E-08 4.69E-08 1.13E-08 1.41E-08 2.04E-08 2.82E-08 4.82E-08 1.03E-08 1.27E-08 1.75E-08 2.42E-08 3.95E-08 1.04E-08 1.31E-08 1.90E-08 2.68E-08 4.51E-08 1.02E-08 1.29E-08 1.85E-08 2.55E-08 4.37E-08 1.01E-08 1.30E-08 1.84E-08 2.57E-08 4.33E-08 9.64E-09 1.23E-08 1.77E-08 2.48E-08 4.19E-08 1.06E-08 1.05E-08 1.06E-08 1.05E-08 1.06E-08 1.09E-08 6.12E-10 1.26E-08 9.23E-09 1.37E-08 7.54E-10 1.58E-08 1.16E-08 1.95E-08 1.06E-09 2.24E-08 1.67E-08 2.69E-08 1.43E-09 3.08E-08 2.30E-08 4.52E-08 2.64E-09 5.25E-08 3.80E-08 1.02E-08 1.28E-08 1.82E-08 2.54E-08 4.27E-08 3.10E-10 3.32E-10 5.90E-10 1.00E-09 2.12E-09 1.10E-08 1.37E-08 1.98E-08 2.82E-08 4.85E-08 9.30E-09 1.19E-08 1.66E-08 2.27E-08 3.69E-08 -3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07 PASS PASS PASS PASS PASS 3.00E-08 7.50E-08 1.00E-07 1.75E-07 2.50E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 32 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 3 @ +/-15V (A) 3.00E-07 2.00E-07 1.00E-07 0.00E+00 -1.00E-07 -2.00E-07 -3.00E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.13. Plot of Positive Bias Current 3 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 33 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.13. Raw data for Positive Bias Current 3 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Bias Current 3 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.07E-08 1.33E-08 1.89E-08 2.60E-08 4.40E-08 1.06E-08 1.30E-08 1.85E-08 2.56E-08 4.29E-08 9.47E-09 1.22E-08 1.77E-08 2.43E-08 4.03E-08 1.04E-08 1.34E-08 1.92E-08 2.62E-08 4.37E-08 1.10E-08 1.37E-08 1.99E-08 2.73E-08 4.65E-08 1.05E-08 1.28E-08 1.78E-08 2.43E-08 3.98E-08 1.02E-08 1.28E-08 1.84E-08 2.61E-08 4.40E-08 1.05E-08 1.33E-08 1.90E-08 2.64E-08 4.44E-08 9.74E-09 1.25E-08 1.76E-08 2.47E-08 4.14E-08 8.76E-09 1.12E-08 1.61E-08 2.27E-08 3.86E-08 1.03E-08 1.02E-08 1.03E-08 1.02E-08 1.02E-08 1.04E-08 5.76E-10 1.20E-08 8.84E-09 1.31E-08 5.92E-10 1.47E-08 1.15E-08 1.88E-08 8.41E-10 2.11E-08 1.65E-08 2.59E-08 1.11E-09 2.89E-08 2.28E-08 4.35E-08 2.23E-09 4.96E-08 3.74E-08 9.95E-09 1.25E-08 1.78E-08 2.48E-08 4.16E-08 7.34E-10 8.23E-10 1.06E-09 1.50E-09 2.54E-09 1.20E-08 1.48E-08 2.07E-08 2.90E-08 4.86E-08 7.94E-09 1.03E-08 1.49E-08 2.07E-08 3.47E-08 -3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07 PASS PASS PASS PASS PASS 3.00E-08 7.50E-08 1.00E-07 1.75E-07 2.50E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 34 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 4 @ +/-15V (A) 3.00E-07 2.00E-07 1.00E-07 0.00E+00 -1.00E-07 -2.00E-07 -3.00E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.14. Plot of Positive Bias Current 4 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 35 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.14. Raw data for Positive Bias Current 4 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Bias Current 4 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.07E-08 1.35E-08 1.91E-08 2.68E-08 4.52E-08 1.08E-08 1.34E-08 1.91E-08 2.66E-08 4.47E-08 9.78E-09 1.26E-08 1.84E-08 2.55E-08 4.26E-08 1.14E-08 1.46E-08 2.09E-08 2.87E-08 4.74E-08 1.03E-08 1.31E-08 1.91E-08 2.65E-08 4.51E-08 1.09E-08 1.34E-08 1.86E-08 2.53E-08 4.14E-08 1.05E-08 1.31E-08 1.87E-08 2.62E-08 4.38E-08 1.07E-08 1.31E-08 1.83E-08 2.49E-08 4.09E-08 1.03E-08 1.31E-08 1.84E-08 2.54E-08 4.26E-08 1.06E-08 1.34E-08 1.89E-08 2.59E-08 4.37E-08 1.07E-08 1.07E-08 1.07E-08 1.07E-08 1.07E-08 1.06E-08 6.11E-10 1.23E-08 8.94E-09 1.35E-08 7.39E-10 1.55E-08 1.14E-08 1.93E-08 9.48E-10 2.19E-08 1.67E-08 2.68E-08 1.13E-09 2.99E-08 2.37E-08 4.50E-08 1.69E-09 4.96E-08 4.04E-08 1.06E-08 1.32E-08 1.86E-08 2.55E-08 4.25E-08 2.20E-10 1.49E-10 2.34E-10 5.13E-10 1.31E-09 1.12E-08 1.36E-08 1.92E-08 2.70E-08 4.61E-08 1.00E-08 1.28E-08 1.79E-08 2.41E-08 3.89E-08 -3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07 PASS PASS PASS PASS PASS 3.00E-08 7.50E-08 1.00E-07 1.75E-07 2.50E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 36 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 1 @ +/-15V (A) 3.00E-07 2.00E-07 1.00E-07 0.00E+00 -1.00E-07 -2.00E-07 -3.00E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.15. Plot of Negative Bias Current 1 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 37 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.15. Raw data for Negative Bias Current 1 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Bias Current 1 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.03E-08 1.29E-08 1.84E-08 2.59E-08 4.38E-08 1.06E-08 1.31E-08 1.86E-08 2.60E-08 4.36E-08 9.58E-09 1.23E-08 1.79E-08 2.50E-08 4.21E-08 1.11E-08 1.42E-08 2.04E-08 2.82E-08 4.66E-08 9.94E-09 1.27E-08 1.84E-08 2.56E-08 4.31E-08 9.97E-09 1.22E-08 1.69E-08 2.31E-08 3.80E-08 1.00E-08 1.26E-08 1.79E-08 2.48E-08 4.09E-08 1.02E-08 1.26E-08 1.76E-08 2.39E-08 3.99E-08 9.98E-09 1.27E-08 1.77E-08 2.44E-08 4.10E-08 1.02E-08 1.29E-08 1.82E-08 2.50E-08 4.17E-08 9.85E-09 9.81E-09 9.80E-09 9.83E-09 9.84E-09 1.03E-08 5.89E-10 1.19E-08 8.69E-09 1.30E-08 7.30E-10 1.50E-08 1.10E-08 1.87E-08 9.73E-10 2.14E-08 1.61E-08 2.61E-08 1.18E-09 2.94E-08 2.29E-08 4.38E-08 1.69E-09 4.85E-08 3.92E-08 1.01E-08 1.26E-08 1.77E-08 2.42E-08 4.03E-08 1.10E-10 2.54E-10 4.66E-10 7.41E-10 1.45E-09 1.04E-08 1.33E-08 1.89E-08 2.63E-08 4.43E-08 9.77E-09 1.19E-08 1.64E-08 2.22E-08 3.63E-08 -3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07 PASS PASS PASS PASS PASS 3.00E-08 7.50E-08 1.00E-07 1.75E-07 2.50E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 38 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 2 @ +/-15V (A) 3.00E-07 2.00E-07 1.00E-07 0.00E+00 -1.00E-07 -2.00E-07 -3.00E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.16. Plot of Negative Bias Current 2 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 39 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.16. Raw data for Negative Bias Current 2 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Bias Current 2 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.12E-08 1.38E-08 1.96E-08 2.69E-08 4.55E-08 1.09E-08 1.35E-08 1.92E-08 2.66E-08 4.47E-08 9.80E-09 1.25E-08 1.80E-08 2.49E-08 4.15E-08 1.13E-08 1.45E-08 2.06E-08 2.81E-08 4.66E-08 1.13E-08 1.42E-08 2.05E-08 2.81E-08 4.80E-08 1.03E-08 1.26E-08 1.76E-08 2.43E-08 3.98E-08 1.04E-08 1.31E-08 1.88E-08 2.65E-08 4.36E-08 1.01E-08 1.29E-08 1.84E-08 2.55E-08 4.23E-08 1.01E-08 1.30E-08 1.83E-08 2.57E-08 4.29E-08 9.55E-09 1.22E-08 1.75E-08 2.47E-08 4.16E-08 1.05E-08 1.05E-08 1.05E-08 1.05E-08 1.05E-08 1.09E-08 6.36E-10 1.26E-08 9.16E-09 1.37E-08 7.68E-10 1.58E-08 1.16E-08 1.96E-08 1.05E-09 2.25E-08 1.67E-08 2.69E-08 1.35E-09 3.06E-08 2.32E-08 4.53E-08 2.42E-09 5.19E-08 3.86E-08 1.01E-08 1.28E-08 1.81E-08 2.53E-08 4.21E-08 3.40E-10 3.67E-10 5.41E-10 8.97E-10 1.44E-09 1.10E-08 1.38E-08 1.96E-08 2.78E-08 4.60E-08 9.18E-09 1.18E-08 1.66E-08 2.29E-08 3.81E-08 -3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07 PASS PASS PASS PASS PASS 3.00E-08 7.50E-08 1.00E-07 1.75E-07 2.50E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 40 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 3 @ +/-15V (A) 3.00E-07 2.00E-07 1.00E-07 0.00E+00 -1.00E-07 -2.00E-07 -3.00E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.17. Plot of Negative Bias Current 3 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 41 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.17. Raw data for Negative Bias Current 3 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Bias Current 3 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.06E-08 1.31E-08 1.87E-08 2.59E-08 4.41E-08 1.06E-08 1.31E-08 1.86E-08 2.58E-08 4.36E-08 9.48E-09 1.22E-08 1.76E-08 2.43E-08 4.08E-08 1.04E-08 1.34E-08 1.92E-08 2.62E-08 4.38E-08 1.09E-08 1.37E-08 1.99E-08 2.72E-08 4.63E-08 1.04E-08 1.27E-08 1.77E-08 2.44E-08 3.98E-08 1.02E-08 1.28E-08 1.83E-08 2.58E-08 4.21E-08 1.03E-08 1.30E-08 1.86E-08 2.58E-08 4.28E-08 9.68E-09 1.24E-08 1.76E-08 2.48E-08 4.15E-08 8.76E-09 1.12E-08 1.62E-08 2.30E-08 3.89E-08 1.02E-08 1.02E-08 1.02E-08 1.02E-08 1.02E-08 1.04E-08 5.48E-10 1.19E-08 8.90E-09 1.31E-08 5.74E-10 1.47E-08 1.15E-08 1.88E-08 8.26E-10 2.11E-08 1.65E-08 2.59E-08 1.07E-09 2.88E-08 2.29E-08 4.37E-08 1.96E-09 4.91E-08 3.83E-08 9.87E-09 1.24E-08 1.77E-08 2.48E-08 4.10E-08 6.79E-10 7.12E-10 9.18E-10 1.17E-09 1.63E-09 1.17E-08 1.44E-08 2.02E-08 2.80E-08 4.55E-08 8.00E-09 1.05E-08 1.52E-08 2.16E-08 3.66E-08 -3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07 PASS PASS PASS PASS PASS 3.00E-08 7.50E-08 1.00E-07 1.75E-07 2.50E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 42 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 4 @ +/-15V (A) 3.00E-07 2.00E-07 1.00E-07 0.00E+00 -1.00E-07 -2.00E-07 -3.00E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.18. Plot of Negative Bias Current 4 @ +/-15V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 43 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.18. Raw data for Negative Bias Current 4 @ +/-15V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Bias Current 4 @ +/-15V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.07E-08 1.33E-08 1.91E-08 2.67E-08 4.50E-08 1.09E-08 1.35E-08 1.92E-08 2.67E-08 4.49E-08 9.85E-09 1.27E-08 1.85E-08 2.59E-08 4.34E-08 1.14E-08 1.46E-08 2.08E-08 2.87E-08 4.74E-08 1.04E-08 1.31E-08 1.90E-08 2.64E-08 4.46E-08 1.09E-08 1.34E-08 1.85E-08 2.53E-08 4.14E-08 1.06E-08 1.30E-08 1.85E-08 2.56E-08 4.23E-08 1.05E-08 1.31E-08 1.83E-08 2.46E-08 4.12E-08 1.03E-08 1.30E-08 1.84E-08 2.53E-08 4.23E-08 1.05E-08 1.32E-08 1.86E-08 2.55E-08 4.26E-08 1.07E-08 1.06E-08 1.07E-08 1.06E-08 1.06E-08 1.06E-08 5.86E-10 1.22E-08 9.03E-09 1.35E-08 7.14E-10 1.54E-08 1.15E-08 1.93E-08 8.81E-10 2.17E-08 1.69E-08 2.69E-08 1.06E-09 2.98E-08 2.40E-08 4.51E-08 1.46E-09 4.91E-08 4.11E-08 1.06E-08 1.31E-08 1.85E-08 2.53E-08 4.20E-08 2.21E-10 1.46E-10 1.18E-10 3.77E-10 6.17E-10 1.12E-08 1.35E-08 1.88E-08 2.63E-08 4.37E-08 9.95E-09 1.27E-08 1.81E-08 2.42E-08 4.03E-08 -3.00E-08 -7.50E-08 -1.00E-07 -1.75E-07 -2.50E-07 PASS PASS PASS PASS PASS 3.00E-08 7.50E-08 1.00E-07 1.75E-07 2.50E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 44 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio 1 (dB) 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.19. Plot of Common Mode Rejection Ratio 1 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 45 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.19. Raw data for Common Mode Rejection Ratio 1 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio 1 (dB) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.15E+02 1.10E+02 1.13E+02 1.12E+02 1.17E+02 1.13E+02 1.19E+02 1.16E+02 1.42E+02 1.21E+02 1.10E+02 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.12E+02 1.11E+02 1.11E+02 1.09E+02 1.08E+02 1.07E+02 1.11E+02 1.10E+02 1.09E+02 1.10E+02 1.09E+02 1.09E+02 1.14E+02 1.13E+02 1.12E+02 1.11E+02 1.10E+02 1.08E+02 1.16E+02 1.14E+02 1.12E+02 1.14E+02 1.12E+02 1.11E+02 1.27E+02 1.21E+02 1.18E+02 1.29E+02 1.50E+02 1.28E+02 1.10E+02 1.10E+02 1.10E+02 2/16/2012 200 1.09E+02 1.06E+02 1.08E+02 1.08E+02 1.10E+02 1.07E+02 1.10E+02 1.09E+02 1.14E+02 1.18E+02 1.10E+02 1.14E+02 2.52E+00 1.20E+02 1.07E+02 1.11E+02 1.96E+00 1.17E+02 1.06E+02 1.10E+02 1.89E+00 1.16E+02 1.05E+02 1.10E+02 1.67E+00 1.14E+02 1.05E+02 1.08E+02 1.43E+00 1.12E+02 1.04E+02 1.22E+02 1.16E+01 1.54E+02 9.04E+01 9.70E+01 PASS 1.19E+02 7.92E+00 1.41E+02 9.74E+01 9.70E+01 PASS 1.21E+02 1.64E+01 1.66E+02 7.63E+01 9.40E+01 PASS 1.15E+02 7.76E+00 1.37E+02 9.42E+01 9.00E+01 PASS 1.12E+02 4.31E+00 1.23E+02 9.97E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 46 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio 2 (dB) 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.20. Plot of Common Mode Rejection Ratio 2 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 47 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.20. Raw data for Common Mode Rejection Ratio 2 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio 2 (dB) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.13E+02 1.08E+02 1.12E+02 1.10E+02 1.09E+02 1.14E+02 1.18E+02 1.12E+02 1.18E+02 1.19E+02 1.17E+02 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.11E+02 1.10E+02 1.09E+02 1.06E+02 1.06E+02 1.05E+02 1.10E+02 1.09E+02 1.09E+02 1.08E+02 1.08E+02 1.07E+02 1.08E+02 1.07E+02 1.07E+02 1.12E+02 1.10E+02 1.09E+02 1.15E+02 1.13E+02 1.12E+02 1.11E+02 1.10E+02 1.09E+02 1.15E+02 1.14E+02 1.12E+02 1.16E+02 1.14E+02 1.12E+02 1.17E+02 1.17E+02 1.17E+02 2/16/2012 200 1.08E+02 1.05E+02 1.07E+02 1.06E+02 1.06E+02 1.07E+02 1.09E+02 1.07E+02 1.10E+02 1.09E+02 1.17E+02 1.10E+02 2.24E+00 1.16E+02 1.04E+02 1.09E+02 1.72E+00 1.13E+02 1.04E+02 1.08E+02 1.61E+00 1.12E+02 1.04E+02 1.07E+02 1.49E+00 1.12E+02 1.03E+02 1.06E+02 1.27E+00 1.10E+02 1.03E+02 1.16E+02 3.12E+00 1.25E+02 1.08E+02 9.70E+01 PASS 1.14E+02 2.35E+00 1.20E+02 1.07E+02 9.70E+01 PASS 1.12E+02 1.96E+00 1.17E+02 1.07E+02 9.40E+01 PASS 1.11E+02 1.63E+00 1.15E+02 1.06E+02 9.00E+01 PASS 1.09E+02 1.33E+00 1.12E+02 1.05E+02 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 48 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio 3 (dB) 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.21. Plot of Common Mode Rejection Ratio 3 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 49 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.21. Raw data for Common Mode Rejection Ratio 3 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio 3 (dB) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.14E+02 1.10E+02 1.13E+02 1.09E+02 1.11E+02 1.12E+02 1.53E+02 1.22E+02 1.13E+02 1.20E+02 1.16E+02 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.12E+02 1.11E+02 1.10E+02 1.09E+02 1.08E+02 1.07E+02 1.10E+02 1.10E+02 1.09E+02 1.07E+02 1.07E+02 1.06E+02 1.10E+02 1.09E+02 1.09E+02 1.10E+02 1.09E+02 1.08E+02 1.27E+02 1.21E+02 1.18E+02 1.18E+02 1.15E+02 1.13E+02 1.11E+02 1.10E+02 1.09E+02 1.16E+02 1.14E+02 1.12E+02 1.16E+02 1.16E+02 1.16E+02 2/16/2012 200 1.08E+02 1.06E+02 1.08E+02 1.05E+02 1.08E+02 1.06E+02 1.13E+02 1.10E+02 1.07E+02 1.10E+02 1.16E+02 1.11E+02 2.06E+00 1.17E+02 1.06E+02 1.10E+02 1.65E+00 1.14E+02 1.05E+02 1.09E+02 1.53E+00 1.13E+02 1.05E+02 1.08E+02 1.46E+00 1.12E+02 1.04E+02 1.07E+02 1.27E+00 1.10E+02 1.03E+02 1.24E+02 1.68E+01 1.70E+02 7.77E+01 9.70E+01 PASS 1.17E+02 6.94E+00 1.36E+02 9.75E+01 9.70E+01 PASS 1.14E+02 5.01E+00 1.28E+02 1.00E+02 9.40E+01 PASS 1.12E+02 3.97E+00 1.23E+02 1.01E+02 9.00E+01 PASS 1.09E+02 2.77E+00 1.17E+02 1.02E+02 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 50 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio 4 (dB) 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.22. Plot of Common Mode Rejection Ratio 4 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 51 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.22. Raw data for Common Mode Rejection Ratio 4 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio 4 (dB) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.16E+02 1.07E+02 1.17E+02 1.16E+02 1.11E+02 1.15E+02 1.17E+02 1.14E+02 1.45E+02 1.30E+02 1.21E+02 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.14E+02 1.13E+02 1.12E+02 1.06E+02 1.05E+02 1.05E+02 1.14E+02 1.13E+02 1.12E+02 1.13E+02 1.12E+02 1.11E+02 1.10E+02 1.09E+02 1.09E+02 1.12E+02 1.11E+02 1.09E+02 1.15E+02 1.14E+02 1.13E+02 1.11E+02 1.10E+02 1.09E+02 1.27E+02 1.21E+02 1.18E+02 1.35E+02 1.25E+02 1.21E+02 1.21E+02 1.21E+02 1.21E+02 2/16/2012 200 1.10E+02 1.04E+02 1.10E+02 1.09E+02 1.07E+02 1.07E+02 1.10E+02 1.07E+02 1.14E+02 1.15E+02 1.21E+02 1.14E+02 4.47E+00 1.26E+02 1.01E+02 1.11E+02 3.55E+00 1.21E+02 1.01E+02 1.10E+02 3.24E+00 1.19E+02 1.01E+02 1.09E+02 2.95E+00 1.18E+02 1.01E+02 1.08E+02 2.63E+00 1.15E+02 1.01E+02 1.24E+02 1.35E+01 1.61E+02 8.70E+01 9.70E+01 PASS 1.20E+02 1.06E+01 1.49E+02 9.12E+01 9.70E+01 PASS 1.16E+02 6.77E+00 1.35E+02 9.76E+01 9.40E+01 PASS 1.14E+02 5.33E+00 1.28E+02 9.92E+01 9.00E+01 PASS 1.11E+02 3.80E+00 1.21E+02 1.00E+02 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 52 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio 1 (dB) 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.23. Plot of Power Supply Rejection Ratio 1 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 53 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.23. Raw data for Power Supply Rejection Ratio 1 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio 1 (dB) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.46E+02 1.43E+02 1.33E+02 1.37E+02 1.26E+02 1.33E+02 1.32E+02 1.30E+02 1.23E+02 1.20E+02 1.25E+02 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.33E+02 1.30E+02 1.28E+02 1.33E+02 1.30E+02 1.29E+02 1.51E+02 1.45E+02 1.36E+02 1.31E+02 1.29E+02 1.27E+02 1.31E+02 1.31E+02 1.38E+02 1.39E+02 1.57E+02 1.36E+02 1.37E+02 1.45E+02 1.52E+02 1.29E+02 1.26E+02 1.23E+02 1.24E+02 1.27E+02 1.29E+02 1.21E+02 1.22E+02 1.24E+02 1.25E+02 1.25E+02 1.25E+02 2/16/2012 200 1.23E+02 1.23E+02 1.30E+02 1.22E+02 1.35E+02 1.24E+02 1.28E+02 1.18E+02 1.42E+02 1.29E+02 1.25E+02 1.37E+02 7.86E+00 1.58E+02 1.15E+02 1.36E+02 8.51E+00 1.59E+02 1.12E+02 1.33E+02 6.56E+00 1.51E+02 1.15E+02 1.32E+02 5.15E+00 1.46E+02 1.18E+02 1.27E+02 5.63E+00 1.42E+02 1.11E+02 1.28E+02 5.61E+00 1.43E+02 1.12E+02 1.00E+02 PASS 1.30E+02 7.65E+00 1.51E+02 1.09E+02 9.80E+01 PASS 1.35E+02 1.49E+01 1.76E+02 9.47E+01 9.40E+01 PASS 1.33E+02 1.19E+01 1.65E+02 1.00E+02 8.60E+01 PASS 1.28E+02 9.05E+00 1.53E+02 1.03E+02 8.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 54 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio 2 (dB) 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.24. Plot of Power Supply Rejection Ratio 2 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 55 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.24. Raw data for Power Supply Rejection Ratio 2 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio 2 (dB) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.29E+02 1.42E+02 1.35E+02 1.26E+02 1.22E+02 1.27E+02 1.33E+02 1.28E+02 1.32E+02 1.29E+02 1.26E+02 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.32E+02 1.36E+02 1.52E+02 1.33E+02 1.30E+02 1.28E+02 1.48E+02 1.44E+02 1.38E+02 1.24E+02 1.23E+02 1.21E+02 1.22E+02 1.21E+02 1.20E+02 1.28E+02 1.33E+02 1.56E+02 1.36E+02 1.40E+02 1.42E+02 1.30E+02 1.33E+02 1.36E+02 1.29E+02 1.27E+02 1.24E+02 1.27E+02 1.26E+02 1.23E+02 1.27E+02 1.26E+02 1.26E+02 2/16/2012 200 1.30E+02 1.23E+02 1.28E+02 1.18E+02 1.18E+02 1.29E+02 1.28E+02 1.35E+02 1.19E+02 1.19E+02 1.26E+02 1.31E+02 7.83E+00 1.52E+02 1.09E+02 1.32E+02 1.03E+01 1.60E+02 1.03E+02 1.31E+02 9.56E+00 1.57E+02 1.05E+02 1.32E+02 1.32E+01 1.68E+02 9.53E+01 1.23E+02 5.41E+00 1.38E+02 1.09E+02 1.30E+02 2.59E+00 1.37E+02 1.23E+02 1.00E+02 PASS 1.30E+02 3.43E+00 1.40E+02 1.21E+02 9.80E+01 PASS 1.32E+02 5.91E+00 1.48E+02 1.15E+02 9.40E+01 PASS 1.36E+02 1.34E+01 1.73E+02 9.96E+01 8.60E+01 PASS 1.26E+02 7.09E+00 1.46E+02 1.07E+02 8.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 56 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio 3 (dB) 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.25. Plot of Power Supply Rejection Ratio 3 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 57 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.25. Raw data for Power Supply Rejection Ratio 3 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio 3 (dB) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.28E+02 1.24E+02 1.42E+02 1.33E+02 1.44E+02 1.56E+02 1.21E+02 1.35E+02 1.33E+02 1.32E+02 1.23E+02 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.25E+02 1.23E+02 1.21E+02 1.27E+02 1.29E+02 1.32E+02 1.45E+02 1.33E+02 1.31E+02 1.28E+02 1.27E+02 1.25E+02 1.38E+02 1.34E+02 1.31E+02 1.42E+02 1.34E+02 1.29E+02 1.22E+02 1.24E+02 1.25E+02 1.40E+02 1.52E+02 1.36E+02 1.32E+02 1.30E+02 1.26E+02 1.35E+02 1.40E+02 1.40E+02 1.23E+02 1.22E+02 1.22E+02 2/16/2012 200 1.18E+02 1.63E+02 1.24E+02 1.21E+02 1.25E+02 1.21E+02 1.38E+02 1.26E+02 1.21E+02 1.28E+02 1.22E+02 1.34E+02 8.57E+00 1.58E+02 1.11E+02 1.33E+02 8.49E+00 1.56E+02 1.09E+02 1.29E+02 4.19E+00 1.41E+02 1.18E+02 1.28E+02 4.55E+00 1.40E+02 1.15E+02 1.30E+02 1.83E+01 1.80E+02 8.00E+01 1.36E+02 1.26E+01 1.70E+02 1.01E+02 1.00E+02 PASS 1.34E+02 7.92E+00 1.56E+02 1.13E+02 9.80E+01 PASS 1.36E+02 1.07E+01 1.65E+02 1.07E+02 9.40E+01 PASS 1.31E+02 6.86E+00 1.50E+02 1.12E+02 8.60E+01 PASS 1.27E+02 6.82E+00 1.45E+02 1.08E+02 8.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 58 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio 4 (dB) 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.26. Plot of Power Supply Rejection Ratio 4 (dB) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 59 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.26. Raw data for Power Supply Rejection Ratio 4 (dB) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio 4 (dB) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.27E+02 1.26E+02 1.29E+02 1.27E+02 1.49E+02 1.28E+02 1.21E+02 1.33E+02 1.22E+02 1.21E+02 1.37E+02 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.31E+02 1.34E+02 1.39E+02 1.25E+02 1.24E+02 1.22E+02 1.35E+02 1.38E+02 1.52E+02 1.31E+02 1.33E+02 1.54E+02 1.42E+02 1.34E+02 1.31E+02 1.27E+02 1.25E+02 1.22E+02 1.22E+02 1.22E+02 1.24E+02 1.42E+02 1.45E+02 1.32E+02 1.24E+02 1.25E+02 1.29E+02 1.23E+02 1.24E+02 1.26E+02 1.37E+02 1.36E+02 1.35E+02 2/16/2012 200 1.39E+02 1.19E+02 1.31E+02 1.32E+02 1.25E+02 1.18E+02 1.30E+02 1.23E+02 1.80E+02 1.41E+02 1.37E+02 1.32E+02 9.66E+00 1.58E+02 1.05E+02 1.33E+02 6.23E+00 1.50E+02 1.16E+02 1.33E+02 5.23E+00 1.47E+02 1.18E+02 1.40E+02 1.35E+01 1.77E+02 1.03E+02 1.29E+02 7.56E+00 1.50E+02 1.09E+02 1.25E+02 5.32E+00 1.40E+02 1.11E+02 1.00E+02 PASS 1.27E+02 8.25E+00 1.50E+02 1.05E+02 9.80E+01 PASS 1.28E+02 9.65E+00 1.55E+02 1.02E+02 9.40E+01 PASS 1.27E+02 4.03E+00 1.38E+02 1.16E+02 8.60E+01 PASS 1.39E+02 2.49E+01 2.07E+02 7.03E+01 8.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 60 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) 4.00E+05 2.00E+05 0.00E+00 -2.00E+05 -4.00E+05 -6.00E+05 -8.00E+05 -1.00E+06 -1.20E+06 -1.40E+06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.27. Plot of Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 61 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.27. Raw data for Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 3.54E+04 9.32E+03 1.45E+04 1.56E+04 1.55E+04 1.14E+04 8.15E+04 5.83E+04 8.32E+04 1.51E+05 2.86E+04 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 3.04E+04 1.06E+04 5.84E+03 7.96E+03 5.54E+03 3.69E+03 1.29E+04 6.85E+03 4.97E+03 1.13E+04 6.67E+03 4.46E+03 1.39E+04 7.83E+03 5.08E+03 9.53E+03 4.92E+03 4.41E+03 1.22E+06 1.89E+04 8.56E+03 1.61E+04 7.46E+03 6.16E+03 2.86E+04 1.91E+04 6.73E+03 1.51E+05 2.74E+04 9.46E+03 2.70E+04 2.95E+04 2.71E+04 2/16/2012 200 2.51E+03 1.84E+03 2.22E+03 1.86E+03 2.35E+03 2.06E+03 3.34E+03 2.05E+03 2.66E+03 2.68E+03 2.16E+04 1.81E+04 1.00E+04 4.55E+04 -9.38E+03 1.53E+04 8.74E+03 3.92E+04 -8.68E+03 7.49E+03 1.91E+03 1.27E+04 2.27E+03 4.81E+03 7.96E+02 6.99E+03 2.63E+03 2.16E+03 2.97E+02 2.97E+03 1.34E+03 7.72E+04 5.06E+04 2.16E+05 -6.15E+04 1.20E+03 PASS 2.86E+05 5.27E+05 1.73E+06 -1.16E+06 2.00E+02 PASS 1.56E+04 9.26E+03 4.10E+04 -9.83E+03 1.00E+02 PASS 7.06E+03 1.99E+03 1.25E+04 1.59E+03 5.00E+01 PASS 2.56E+03 5.34E+02 4.02E+03 1.09E+03 2.50E+01 PASS An ISO 9001:2008 and DSCC Certified Company 62 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) 4.00E+05 2.00E+05 0.00E+00 -2.00E+05 -4.00E+05 -6.00E+05 -8.00E+05 -1.00E+06 -1.20E+06 -1.40E+06 -1.60E+06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.28. Plot of Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 63 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.28. Raw data for Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.19E+04 7.90E+03 1.58E+04 1.62E+04 1.34E+06 1.18E+04 4.39E+04 6.04E+04 3.59E+05 7.98E+04 1.90E+05 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.04E+04 6.55E+03 5.11E+03 6.60E+03 5.25E+03 3.53E+03 1.24E+04 8.47E+03 5.23E+03 1.33E+04 6.71E+03 4.72E+03 6.21E+04 1.68E+04 9.23E+03 9.20E+03 6.16E+03 4.15E+03 1.05E+05 4.96E+04 1.08E+04 2.18E+04 8.98E+03 6.29E+03 1.27E+05 3.98E+04 9.81E+03 5.09E+05 2.93E+04 1.11E+04 6.98E+04 6.49E+04 9.92E+04 2/16/2012 200 2.01E+03 1.70E+03 2.33E+03 2.03E+03 2.95E+03 2.40E+03 3.14E+03 2.91E+03 3.50E+03 3.42E+03 8.98E+04 2.79E+05 5.95E+05 1.91E+06 -1.35E+06 2.10E+04 2.31E+04 8.44E+04 -4.25E+04 8.75E+03 4.62E+03 2.14E+04 -3.92E+03 5.56E+03 2.15E+03 1.15E+04 -3.43E+02 2.20E+03 4.71E+02 3.49E+03 9.10E+02 1.11E+05 1.41E+05 4.97E+05 -2.75E+05 1.20E+03 PASS 1.55E+05 2.05E+05 7.16E+05 -4.07E+05 2.00E+02 PASS 2.68E+04 1.90E+04 7.89E+04 -2.53E+04 1.00E+02 PASS 8.43E+03 3.07E+03 1.68E+04 2.05E+01 5.00E+01 PASS 3.07E+03 4.45E+02 4.29E+03 1.85E+03 2.50E+01 PASS An ISO 9001:2008 and DSCC Certified Company 64 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) 4.00E+05 2.00E+05 0.00E+00 -2.00E+05 -4.00E+05 -6.00E+05 -8.00E+05 -1.00E+06 -1.20E+06 -1.40E+06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.29. Plot of Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 65 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.29. Raw data for Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.29E+04 8.58E+03 2.43E+04 1.12E+04 1.29E+05 1.68E+04 6.09E+04 5.10E+04 1.20E+06 7.41E+04 4.89E+04 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.13E+04 7.46E+03 4.59E+03 7.40E+03 5.04E+03 3.84E+03 1.22E+04 9.01E+03 5.58E+03 9.86E+03 5.08E+03 3.96E+03 3.76E+04 2.13E+04 8.67E+03 1.31E+04 8.80E+03 4.58E+03 1.98E+05 8.34E+05 8.97E+03 1.93E+05 9.29E+04 1.06E+04 1.08E+05 1.57E+04 7.73E+03 4.37E+04 9.82E+03 8.00E+03 4.11E+04 5.48E+04 3.78E+04 2/16/2012 200 2.11E+03 1.74E+03 2.52E+03 1.79E+03 2.78E+03 2.31E+03 2.97E+03 2.94E+03 3.05E+03 2.60E+03 6.29E+04 3.72E+04 5.15E+04 1.79E+05 -1.04E+05 1.57E+04 1.24E+04 4.97E+04 -1.83E+04 9.58E+03 6.77E+03 2.81E+04 -8.98E+03 5.33E+03 1.99E+03 1.08E+04 -1.34E+02 2.19E+03 4.55E+02 3.43E+03 9.40E+02 2.82E+05 5.17E+05 1.70E+06 -1.13E+06 1.20E+03 PASS 1.11E+05 8.42E+04 3.42E+05 -1.20E+05 2.00E+02 PASS 1.92E+05 3.61E+05 1.18E+06 -7.96E+05 1.00E+02 PASS 7.97E+03 2.19E+03 1.40E+04 1.95E+03 5.00E+01 PASS 2.77E+03 3.10E+02 3.62E+03 1.92E+03 2.50E+01 PASS An ISO 9001:2008 and DSCC Certified Company 66 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) 3.00E+05 2.00E+05 1.00E+05 0.00E+00 -1.00E+05 -2.00E+05 -3.00E+05 -4.00E+05 -5.00E+05 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.30. Plot of Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 67 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.30. Raw data for Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 2.76E+04 7.85E+03 1.47E+04 1.33E+04 1.68E+04 1.88E+04 2.00E+05 2.17E+04 5.72E+05 8.93E+04 1.83E+05 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 2.17E+04 1.07E+04 6.80E+03 8.35E+03 5.29E+03 3.88E+03 1.14E+04 8.24E+03 5.11E+03 1.32E+04 7.08E+03 4.79E+03 1.40E+04 9.52E+03 7.02E+03 1.43E+04 7.78E+03 4.87E+03 8.37E+04 2.51E+04 8.80E+03 1.74E+04 8.14E+03 5.52E+03 4.22E+04 1.23E+04 9.30E+03 1.64E+05 1.20E+04 1.01E+04 6.03E+05 2.24E+05 2.41E+05 2/16/2012 200 2.56E+03 1.81E+03 2.45E+03 1.94E+03 2.35E+03 2.20E+03 3.23E+03 2.56E+03 3.13E+03 3.71E+03 1.03E+06 1.60E+04 7.26E+03 3.60E+04 -3.86E+03 1.37E+04 4.97E+03 2.74E+04 1.25E+02 8.16E+03 2.09E+03 1.39E+04 2.42E+03 5.52E+03 1.35E+03 9.23E+03 1.82E+03 2.22E+03 3.28E+02 3.12E+03 1.32E+03 1.80E+05 2.31E+05 8.14E+05 -4.53E+05 1.20E+03 PASS 6.43E+04 6.22E+04 2.35E+05 -1.06E+05 2.00E+02 PASS 1.31E+04 7.03E+03 3.23E+04 -6.21E+03 1.00E+02 PASS 7.72E+03 2.36E+03 1.42E+04 1.24E+03 5.00E+01 PASS 2.97E+03 5.94E+02 4.59E+03 1.34E+03 2.50E+01 PASS An ISO 9001:2008 and DSCC Certified Company 68 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 1 @ +/-15V (V) 1.42E+01 1.40E+01 1.38E+01 1.36E+01 1.34E+01 1.32E+01 1.30E+01 1.28E+01 1.26E+01 1.24E+01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.31. Plot of Positive Output Voltage 1 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 69 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.31. Raw data for Positive Output Voltage 1 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 1 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 2/16/2012 200 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 2.70E-03 2.68E-03 2.97E-03 2.88E-03 2.70E-03 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 5.85E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 6.38E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 6.42E-03 1.41E+01 1.40E+01 1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 70 1.41E+01 6.31E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 6.47E-03 1.41E+01 1.40E+01 1.25E+01 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 2 @ +/-15V (V) 1.42E+01 1.40E+01 1.38E+01 1.36E+01 1.34E+01 1.32E+01 1.30E+01 1.28E+01 1.26E+01 1.24E+01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.32. Plot of Positive Output Voltage 2 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 71 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.32. Raw data for Positive Output Voltage 2 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 2 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 2/16/2012 200 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 4.22E-03 4.39E-03 4.49E-03 4.34E-03 4.88E-03 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 5.37E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 5.61E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 5.61E-03 1.41E+01 1.41E+01 1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 72 1.41E+01 5.48E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 5.48E-03 1.41E+01 1.41E+01 1.25E+01 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 3 @ +/-15V (V) 1.42E+01 1.40E+01 1.38E+01 1.36E+01 1.34E+01 1.32E+01 1.30E+01 1.28E+01 1.26E+01 1.24E+01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.33. Plot of Positive Output Voltage 3 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 73 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.33. Raw data for Positive Output Voltage 3 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 3 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 2/16/2012 200 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 4.39E-03 4.00E-03 4.58E-03 4.28E-03 3.96E-03 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.40E+01 1.41E+01 1.40E+01 1.41E+01 6.02E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 5.73E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 6.16E-03 1.41E+01 1.41E+01 1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 74 1.41E+01 6.42E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 6.07E-03 1.41E+01 1.41E+01 1.25E+01 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 4 @ +/-15V (V) 1.42E+01 1.40E+01 1.38E+01 1.36E+01 1.34E+01 1.32E+01 1.30E+01 1.28E+01 1.26E+01 1.24E+01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.34. Plot of Positive Output Voltage 4 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 75 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.34. Raw data for Positive Output Voltage 4 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 4 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 2/16/2012 200 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 2.28E-03 2.86E-03 2.28E-03 2.97E-03 3.05E-03 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 1.41E+01 5.81E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 5.66E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 6.11E-03 1.41E+01 1.41E+01 1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 76 1.41E+01 6.10E-03 1.41E+01 1.41E+01 1.25E+01 PASS 1.41E+01 5.93E-03 1.41E+01 1.41E+01 1.25E+01 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Output Voltage 1 @ +/-15V (V) -1.20E+01 -1.25E+01 -1.30E+01 -1.35E+01 -1.40E+01 -1.45E+01 -1.50E+01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.35. Plot of Negative Output Voltage 1 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 77 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.35. Raw data for Negative Output Voltage 1 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Output Voltage 1 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 2/6/2012 0 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -1.45E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.44E+01 2/16/2012 200 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 3.42E-03 3.51E-03 3.42E-03 4.00E-03 3.54E-03 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 4.56E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.90E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.24E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 78 -1.45E+01 3.94E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.44E+01 3.71E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Output Voltage 2 @ +/-15V (V) -1.20E+01 -1.25E+01 -1.30E+01 -1.35E+01 -1.40E+01 -1.45E+01 -1.50E+01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.36. Plot of Negative Output Voltage 2 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 79 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.36. Raw data for Negative Output Voltage 2 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Output Voltage 2 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 2/6/2012 0 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 2/16/2012 200 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 3.85E-03 3.05E-03 3.16E-03 4.02E-03 3.21E-03 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 4.39E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.24E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.83E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 80 -1.45E+01 4.24E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.44E+01 3.56E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Output Voltage 3 @ +/-15V (V) -1.20E+01 -1.25E+01 -1.30E+01 -1.35E+01 -1.40E+01 -1.45E+01 -1.50E+01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.37. Plot of Negative Output Voltage 3 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 81 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.37. Raw data for Negative Output Voltage 3 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Output Voltage 3 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 2/6/2012 0 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -1.45E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.44E+01 2/16/2012 200 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 3.78E-03 3.29E-03 3.03E-03 3.85E-03 3.35E-03 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 4.55E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.24E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.36E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 82 -1.45E+01 4.49E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.44E+01 3.90E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Output Voltage 4 @ +/-15V (V) -1.20E+01 -1.25E+01 -1.30E+01 -1.35E+01 -1.40E+01 -1.45E+01 -1.50E+01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.38. Plot of Negative Output Voltage 4 @ +/-15V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 83 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.38. Raw data for Negative Output Voltage 4 @ +/-15V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Output Voltage 4 @ +/-15V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 2/6/2012 0 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 2/16/2012 200 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.44E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 3.35E-03 3.03E-03 3.56E-03 3.85E-03 3.42E-03 -1.45E+01 -1.45E+01 -1.44E+01 -1.44E+01 -1.44E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 -1.45E+01 4.38E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.58E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 4.24E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS An ISO 9001:2008 and DSCC Certified Company 84 -1.45E+01 3.77E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS -1.45E+01 3.44E-03 -1.44E+01 -1.45E+01 -1.25E+01 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Slew Rate 1 @ +/-15V (V/us) 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.39. Plot of Positive Slew Rate 1 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 85 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.39. Raw data for Positive Slew Rate 1 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Slew Rate 1 @ +/-15V (V/us) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 4.85E-01 4.86E-01 4.69E-01 4.58E-01 4.14E-01 403 4.84E-01 4.76E-01 4.63E-01 4.54E-01 4.15E-01 408 5.14E-01 5.14E-01 5.12E-01 4.81E-01 4.35E-01 439 4.73E-01 4.68E-01 4.65E-01 4.39E-01 4.06E-01 634 5.22E-01 5.12E-01 5.04E-01 4.80E-01 4.34E-01 720 4.85E-01 4.79E-01 4.75E-01 4.57E-01 4.20E-01 896 5.05E-01 5.02E-01 4.88E-01 4.74E-01 4.21E-01 921 5.14E-01 5.00E-01 4.86E-01 4.62E-01 4.27E-01 923 4.88E-01 4.94E-01 4.70E-01 4.61E-01 4.16E-01 928 5.11E-01 5.03E-01 4.86E-01 4.63E-01 4.14E-01 940 5.07E-01 4.98E-01 5.02E-01 5.00E-01 5.04E-01 Biased Statistics Average Biased 4.96E-01 4.91E-01 4.83E-01 4.62E-01 4.21E-01 Std Dev Biased 2.12E-02 2.09E-02 2.35E-02 1.80E-02 1.30E-02 Ps90%/90% (+KTL) Biased 5.54E-01 5.49E-01 5.47E-01 5.12E-01 4.56E-01 Ps90%/90% (-KTL) Biased 4.38E-01 4.34E-01 4.18E-01 4.13E-01 3.85E-01 Un-Biased Statistics Average Un-Biased 5.01E-01 4.96E-01 4.81E-01 4.63E-01 4.20E-01 Std Dev Un-Biased 1.33E-02 9.91E-03 8.00E-03 6.35E-03 5.03E-03 Ps90%/90% (+KTL) Un-Biased 5.37E-01 5.23E-01 5.03E-01 4.81E-01 4.33E-01 Ps90%/90% (-KTL) Un-Biased 4.64E-01 4.68E-01 4.59E-01 4.46E-01 4.06E-01 Specification MIN 2.00E-01 1.20E-01 1.10E-01 7.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 86 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Slew Rate 2 @ +/-15V (V/us) 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.40. Plot of Positive Slew Rate 2 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 87 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.40. Raw data for Positive Slew Rate 2 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Slew Rate 2 @ +/-15V (V/us) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 5.06E-01 5.27E-01 5.04E-01 4.82E-01 4.41E-01 403 5.19E-01 5.07E-01 4.89E-01 4.89E-01 4.33E-01 408 5.38E-01 5.37E-01 5.09E-01 5.04E-01 4.59E-01 439 5.05E-01 5.20E-01 5.04E-01 4.83E-01 4.42E-01 634 5.55E-01 5.31E-01 5.36E-01 5.09E-01 4.69E-01 720 5.22E-01 5.28E-01 5.10E-01 4.96E-01 4.57E-01 896 5.30E-01 5.18E-01 5.10E-01 4.87E-01 4.43E-01 921 5.25E-01 5.23E-01 5.09E-01 4.81E-01 4.44E-01 923 5.37E-01 5.30E-01 5.10E-01 4.95E-01 4.41E-01 928 5.45E-01 5.39E-01 5.26E-01 5.11E-01 4.64E-01 940 5.35E-01 5.31E-01 5.32E-01 5.20E-01 5.26E-01 Biased Statistics Average Biased 5.25E-01 5.24E-01 5.08E-01 4.93E-01 4.49E-01 Std Dev Biased 2.16E-02 1.15E-02 1.72E-02 1.24E-02 1.47E-02 Ps90%/90% (+KTL) Biased 5.84E-01 5.56E-01 5.55E-01 5.27E-01 4.89E-01 Ps90%/90% (-KTL) Biased 4.65E-01 4.93E-01 4.61E-01 4.59E-01 4.08E-01 Un-Biased Statistics Average Un-Biased 5.32E-01 5.28E-01 5.13E-01 4.94E-01 4.50E-01 Std Dev Un-Biased 9.31E-03 7.89E-03 7.28E-03 1.13E-02 1.01E-02 Ps90%/90% (+KTL) Un-Biased 5.57E-01 5.49E-01 5.33E-01 5.25E-01 4.78E-01 Ps90%/90% (-KTL) Un-Biased 5.06E-01 5.06E-01 4.93E-01 4.63E-01 4.22E-01 Specification MIN 2.00E-01 1.20E-01 1.10E-01 7.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 88 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Slew Rate 3 @ +/-15V (V/us) 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.41. Plot of Positive Slew Rate 3 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 89 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.41. Raw data for Positive Slew Rate 3 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Slew Rate 3 @ +/-15V (V/us) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 4.83E-01 4.80E-01 4.66E-01 4.53E-01 4.06E-01 403 4.78E-01 4.77E-01 4.68E-01 4.58E-01 4.09E-01 408 5.20E-01 4.96E-01 4.99E-01 4.75E-01 4.31E-01 439 4.93E-01 4.90E-01 4.66E-01 4.61E-01 4.21E-01 634 5.25E-01 5.14E-01 5.14E-01 4.83E-01 4.44E-01 720 4.99E-01 4.91E-01 4.91E-01 4.67E-01 4.18E-01 896 4.89E-01 4.96E-01 4.82E-01 4.60E-01 4.17E-01 921 5.13E-01 4.94E-01 4.87E-01 4.65E-01 4.15E-01 923 5.03E-01 4.95E-01 4.83E-01 4.68E-01 4.15E-01 928 5.29E-01 5.28E-01 4.95E-01 4.95E-01 4.30E-01 940 4.95E-01 4.83E-01 4.91E-01 4.84E-01 4.92E-01 Biased Statistics Average Biased 5.00E-01 4.91E-01 4.83E-01 4.66E-01 4.22E-01 Std Dev Biased 2.15E-02 1.48E-02 2.25E-02 1.25E-02 1.57E-02 Ps90%/90% (+KTL) Biased 5.59E-01 5.32E-01 5.44E-01 5.00E-01 4.65E-01 Ps90%/90% (-KTL) Biased 4.41E-01 4.51E-01 4.21E-01 4.32E-01 3.79E-01 Un-Biased Statistics Average Un-Biased 5.07E-01 5.01E-01 4.88E-01 4.71E-01 4.19E-01 Std Dev Un-Biased 1.52E-02 1.53E-02 5.46E-03 1.38E-02 6.28E-03 Ps90%/90% (+KTL) Un-Biased 5.48E-01 5.43E-01 5.03E-01 5.09E-01 4.36E-01 Ps90%/90% (-KTL) Un-Biased 4.65E-01 4.59E-01 4.73E-01 4.33E-01 4.02E-01 Specification MIN 2.00E-01 1.20E-01 1.10E-01 7.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 90 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Slew Rate 4 @ +/-15V (V/us) 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.42. Plot of Positive Slew Rate 4 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 91 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.42. Raw data for Positive Slew Rate 4 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Slew Rate 4 @ +/-15V (V/us) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 5.15E-01 5.16E-01 5.07E-01 4.90E-01 4.46E-01 403 5.14E-01 5.04E-01 4.88E-01 4.77E-01 4.28E-01 408 5.36E-01 5.36E-01 5.35E-01 5.20E-01 4.75E-01 439 5.02E-01 5.00E-01 4.86E-01 4.78E-01 4.31E-01 634 5.40E-01 5.31E-01 5.31E-01 5.14E-01 4.60E-01 720 5.29E-01 5.13E-01 5.10E-01 4.85E-01 4.45E-01 896 5.36E-01 5.13E-01 5.12E-01 4.90E-01 4.43E-01 921 5.50E-01 5.33E-01 5.10E-01 4.99E-01 4.53E-01 923 5.12E-01 5.09E-01 5.01E-01 4.86E-01 4.36E-01 928 5.22E-01 5.25E-01 5.16E-01 4.96E-01 4.40E-01 940 5.27E-01 5.17E-01 5.24E-01 5.19E-01 5.22E-01 Biased Statistics Average Biased 5.21E-01 5.17E-01 5.09E-01 4.96E-01 4.48E-01 Std Dev Biased 1.61E-02 1.59E-02 2.31E-02 2.01E-02 1.98E-02 Ps90%/90% (+KTL) Biased 5.65E-01 5.61E-01 5.73E-01 5.51E-01 5.02E-01 Ps90%/90% (-KTL) Biased 4.77E-01 4.74E-01 4.46E-01 4.41E-01 3.94E-01 Un-Biased Statistics Average Un-Biased 5.30E-01 5.19E-01 5.10E-01 4.91E-01 4.43E-01 Std Dev Un-Biased 1.44E-02 1.00E-02 5.50E-03 6.14E-03 6.35E-03 Ps90%/90% (+KTL) Un-Biased 5.69E-01 5.46E-01 5.25E-01 5.08E-01 4.61E-01 Ps90%/90% (-KTL) Un-Biased 4.90E-01 4.91E-01 4.95E-01 4.74E-01 4.26E-01 Specification MIN 2.00E-01 1.20E-01 1.10E-01 7.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 92 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Slew Rate 1 @ +/-15V (V/us) 0.00E+00 -1.00E-01 -2.00E-01 -3.00E-01 -4.00E-01 -5.00E-01 -6.00E-01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.43. Plot of Negative Slew Rate 1 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 93 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.43. Raw data for Negative Slew Rate 1 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Slew Rate 1 @ +/-15V (V/us) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 2/6/2012 0 -5.48E-01 -5.40E-01 -5.91E-01 -5.41E-01 -5.61E-01 -5.38E-01 -5.48E-01 -5.62E-01 -5.46E-01 -5.45E-01 -5.68E-01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -5.41E-01 -5.23E-01 -5.19E-01 -5.44E-01 -5.08E-01 -5.12E-01 -5.65E-01 -5.67E-01 -5.36E-01 -5.43E-01 -5.34E-01 -4.97E-01 -5.72E-01 -5.58E-01 -5.30E-01 -5.46E-01 -5.28E-01 -5.13E-01 -5.59E-01 -5.34E-01 -5.35E-01 -5.53E-01 -5.47E-01 -5.43E-01 -5.40E-01 -5.29E-01 -5.05E-01 -5.61E-01 -5.42E-01 -5.07E-01 -5.56E-01 -5.49E-01 -5.53E-01 2/16/2012 200 -4.73E-01 -4.68E-01 -4.94E-01 -4.50E-01 -4.96E-01 -4.66E-01 -4.87E-01 -4.78E-01 -4.63E-01 -4.78E-01 -5.61E-01 -5.56E-01 -5.53E-01 -5.38E-01 -5.19E-01 -4.76E-01 2.12E-02 1.44E-02 2.44E-02 1.54E-02 1.92E-02 -4.98E-01 -5.14E-01 -4.71E-01 -4.77E-01 -4.24E-01 -6.14E-01 -5.92E-01 -6.05E-01 -5.61E-01 -5.29E-01 -5.48E-01 8.79E-03 -5.24E-01 -5.72E-01 -2.00E-01 PASS -5.52E-01 8.81E-03 -5.28E-01 -5.76E-01 -1.20E-01 PASS -5.36E-01 8.28E-03 -5.13E-01 -5.59E-01 -1.10E-01 PASS An ISO 9001:2008 and DSCC Certified Company 94 -5.21E-01 1.73E-02 -4.73E-01 -5.68E-01 -7.00E-02 PASS -4.74E-01 9.81E-03 -4.47E-01 -5.01E-01 -1.00E-02 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Slew Rate 2 @ +/-15V (V/us) 0.00E+00 -1.00E-01 -2.00E-01 -3.00E-01 -4.00E-01 -5.00E-01 -6.00E-01 -7.00E-01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.44. Plot of Negative Slew Rate 2 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 95 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.44. Raw data for Negative Slew Rate 2 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Slew Rate 2 @ +/-15V (V/us) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 2/6/2012 0 -5.70E-01 -5.63E-01 -5.98E-01 -5.74E-01 -7.64E-01 -5.94E-01 -5.79E-01 -5.99E-01 -5.91E-01 -6.12E-01 -5.83E-01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -5.62E-01 -5.54E-01 -5.44E-01 -5.69E-01 -5.61E-01 -5.34E-01 -5.92E-01 -5.78E-01 -5.66E-01 -5.77E-01 -5.57E-01 -5.61E-01 -6.16E-01 -5.81E-01 -5.73E-01 -5.82E-01 -5.74E-01 -5.54E-01 -5.79E-01 -5.67E-01 -5.48E-01 -5.66E-01 -5.65E-01 -5.45E-01 -5.98E-01 -5.73E-01 -5.40E-01 -6.07E-01 -6.06E-01 -5.74E-01 -5.69E-01 -5.81E-01 -5.83E-01 2/16/2012 200 -4.95E-01 -4.86E-01 -5.32E-01 -4.88E-01 -5.29E-01 -5.03E-01 -4.90E-01 -4.94E-01 -5.15E-01 -5.35E-01 -5.77E-01 -6.14E-01 -5.83E-01 -5.66E-01 -5.56E-01 -5.06E-01 8.50E-02 2.15E-02 1.24E-02 1.61E-02 2.26E-02 -3.81E-01 -5.24E-01 -5.32E-01 -5.11E-01 -4.44E-01 -8.47E-01 -6.42E-01 -6.00E-01 -6.00E-01 -5.68E-01 -5.95E-01 1.20E-02 -5.62E-01 -6.28E-01 -2.00E-01 PASS -5.86E-01 1.62E-02 -5.42E-01 -6.31E-01 -1.20E-01 PASS -5.77E-01 1.67E-02 -5.31E-01 -6.23E-01 -1.10E-01 PASS An ISO 9001:2008 and DSCC Certified Company 96 -5.52E-01 1.32E-02 -5.16E-01 -5.88E-01 -7.00E-02 PASS -5.07E-01 1.82E-02 -4.58E-01 -5.57E-01 -1.00E-02 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Slew Rate 3 @ +/-15V (V/us) 0.00E+00 -1.00E-01 -2.00E-01 -3.00E-01 -4.00E-01 -5.00E-01 -6.00E-01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.45. Plot of Negative Slew Rate 3 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 97 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.45. Raw data for Negative Slew Rate 3 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Slew Rate 3 @ +/-15V (V/us) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 2/6/2012 0 -5.28E-01 -5.27E-01 -5.76E-01 -5.24E-01 -5.85E-01 -5.67E-01 -5.57E-01 -5.50E-01 -5.59E-01 -5.97E-01 -5.63E-01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -5.34E-01 -5.28E-01 -5.05E-01 -5.34E-01 -5.17E-01 -5.09E-01 -5.66E-01 -5.52E-01 -5.36E-01 -5.31E-01 -5.29E-01 -5.02E-01 -5.75E-01 -5.71E-01 -5.51E-01 -5.51E-01 -5.48E-01 -4.99E-01 -5.46E-01 -5.29E-01 -5.28E-01 -5.53E-01 -5.25E-01 -5.31E-01 -5.61E-01 -5.39E-01 -5.39E-01 -5.74E-01 -5.59E-01 -5.46E-01 -5.45E-01 -5.37E-01 -5.48E-01 2/16/2012 200 -4.61E-01 -4.53E-01 -4.76E-01 -4.74E-01 -4.96E-01 -4.92E-01 -4.76E-01 -4.62E-01 -4.69E-01 -4.98E-01 -5.52E-01 -5.48E-01 -5.48E-01 -5.39E-01 -5.21E-01 -4.72E-01 2.99E-02 2.08E-02 2.18E-02 2.17E-02 1.64E-02 -4.66E-01 -4.91E-01 -4.80E-01 -4.61E-01 -4.27E-01 -6.30E-01 -6.05E-01 -5.99E-01 -5.80E-01 -5.17E-01 -5.66E-01 1.84E-02 -5.16E-01 -6.16E-01 -2.00E-01 PASS -5.57E-01 1.09E-02 -5.27E-01 -5.87E-01 -1.20E-01 PASS -5.40E-01 1.39E-02 -5.02E-01 -5.78E-01 -1.10E-01 PASS An ISO 9001:2008 and DSCC Certified Company 98 -5.29E-01 1.80E-02 -4.79E-01 -5.78E-01 -7.00E-02 PASS -4.79E-01 1.52E-02 -4.38E-01 -5.21E-01 -1.00E-02 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Negative Slew Rate 4 @ +/-15V (V/us) 0.00E+00 -1.00E-01 -2.00E-01 -3.00E-01 -4.00E-01 -5.00E-01 -6.00E-01 -7.00E-01 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.46. Plot of Negative Slew Rate 4 @ +/-15V (V/us) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 99 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.46. Raw data for Negative Slew Rate 4 @ +/-15V (V/us) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Slew Rate 4 @ +/-15V (V/us) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 2/6/2012 0 -5.87E-01 -5.79E-01 -6.21E-01 -5.79E-01 -6.16E-01 -5.95E-01 -5.85E-01 -6.16E-01 -5.78E-01 -5.83E-01 -5.72E-01 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -5.69E-01 -5.54E-01 -5.44E-01 -5.73E-01 -5.53E-01 -5.28E-01 -6.09E-01 -6.02E-01 -5.79E-01 -5.56E-01 -5.46E-01 -5.33E-01 -5.99E-01 -5.86E-01 -5.71E-01 -5.81E-01 -5.67E-01 -5.44E-01 -5.81E-01 -5.70E-01 -5.42E-01 -6.04E-01 -5.66E-01 -5.65E-01 -5.75E-01 -5.59E-01 -5.41E-01 -5.69E-01 -5.58E-01 -5.52E-01 -5.69E-01 -5.98E-01 -5.77E-01 2/16/2012 200 -4.98E-01 -4.90E-01 -5.27E-01 -4.81E-01 -5.25E-01 -5.08E-01 -5.03E-01 -5.28E-01 -4.96E-01 -4.92E-01 -5.86E-01 -5.96E-01 -5.81E-01 -5.68E-01 -5.51E-01 -5.04E-01 2.05E-02 2.20E-02 2.44E-02 2.28E-02 2.08E-02 -5.40E-01 -5.21E-01 -5.01E-01 -4.88E-01 -4.47E-01 -6.53E-01 -6.42E-01 -6.35E-01 -6.14E-01 -5.61E-01 -5.91E-01 1.51E-02 -5.50E-01 -6.33E-01 -2.00E-01 PASS -5.82E-01 1.33E-02 -5.46E-01 -6.18E-01 -1.20E-01 PASS -5.64E-01 5.24E-03 -5.50E-01 -5.78E-01 -1.10E-01 PASS An ISO 9001:2008 and DSCC Certified Company 100 -5.49E-01 1.00E-02 -5.21E-01 -5.76E-01 -7.00E-02 PASS -5.05E-01 1.41E-02 -4.67E-01 -5.44E-01 -1.00E-02 PASS TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Positive Supply Current @ +5V (A) 2.50E-03 2.00E-03 1.50E-03 1.00E-03 5.00E-04 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.47. Plot of Positive Supply Current @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 101 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.47. Raw data for Positive Supply Current @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Supply Current @ +5V (A) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 1.40E-03 1.45E-03 1.40E-03 1.32E-03 1.09E-03 403 1.45E-03 1.47E-03 1.44E-03 1.35E-03 1.13E-03 408 1.48E-03 1.50E-03 1.45E-03 1.36E-03 1.13E-03 439 1.44E-03 1.47E-03 1.42E-03 1.33E-03 1.11E-03 634 1.52E-03 1.51E-03 1.48E-03 1.37E-03 1.15E-03 720 1.46E-03 1.54E-03 1.48E-03 1.39E-03 1.17E-03 896 1.43E-03 1.51E-03 1.44E-03 1.35E-03 1.11E-03 921 1.51E-03 1.52E-03 1.47E-03 1.37E-03 1.13E-03 923 1.41E-03 1.49E-03 1.43E-03 1.34E-03 1.09E-03 928 1.46E-03 1.52E-03 1.46E-03 1.36E-03 1.10E-03 940 1.43E-03 1.43E-03 1.42E-03 1.43E-03 1.43E-03 Biased Statistics Average Biased 1.46E-03 1.48E-03 1.44E-03 1.34E-03 1.12E-03 Std Dev Biased 4.71E-05 2.59E-05 3.10E-05 2.17E-05 2.26E-05 Ps90%/90% (+KTL) Biased 1.59E-03 1.55E-03 1.52E-03 1.40E-03 1.18E-03 Ps90%/90% (-KTL) Biased 1.33E-03 1.41E-03 1.35E-03 1.29E-03 1.06E-03 Un-Biased Statistics Average Un-Biased 1.45E-03 1.52E-03 1.45E-03 1.36E-03 1.12E-03 Std Dev Un-Biased 3.92E-05 2.11E-05 1.83E-05 2.03E-05 2.97E-05 Ps90%/90% (+KTL) Un-Biased 1.56E-03 1.58E-03 1.50E-03 1.42E-03 1.20E-03 Ps90%/90% (-KTL) Un-Biased 1.35E-03 1.46E-03 1.40E-03 1.30E-03 1.04E-03 Specification MAX 2.00E-03 2.00E-03 2.00E-03 2.00E-03 2.00E-03 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 102 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Negative Supply Current @ +5V (A) 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 -2.00E-03 -2.50E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.48. Plot of Negative Supply Current @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 103 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.48. Raw data for Negative Supply Current @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Supply Current @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 -1.37E-03 -1.42E-03 -1.45E-03 -1.41E-03 -1.50E-03 -1.43E-03 -1.41E-03 -1.49E-03 -1.39E-03 -1.44E-03 -1.41E-03 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -1.43E-03 -1.38E-03 -1.30E-03 -1.45E-03 -1.42E-03 -1.32E-03 -1.49E-03 -1.43E-03 -1.33E-03 -1.45E-03 -1.40E-03 -1.31E-03 -1.49E-03 -1.46E-03 -1.36E-03 -1.51E-03 -1.46E-03 -1.36E-03 -1.48E-03 -1.43E-03 -1.32E-03 -1.49E-03 -1.44E-03 -1.34E-03 -1.46E-03 -1.41E-03 -1.31E-03 -1.50E-03 -1.43E-03 -1.32E-03 -1.41E-03 -1.40E-03 -1.41E-03 2/16/2012 200 -1.07E-03 -1.09E-03 -1.11E-03 -1.09E-03 -1.12E-03 -1.13E-03 -1.08E-03 -1.11E-03 -1.07E-03 -1.07E-03 -1.41E-03 -1.43E-03 -1.46E-03 -1.42E-03 -1.32E-03 -1.10E-03 4.87E-05 2.68E-05 2.86E-05 2.29E-05 2.14E-05 -1.30E-03 -1.39E-03 -1.34E-03 -1.26E-03 -1.04E-03 -1.56E-03 -1.53E-03 -1.49E-03 -1.39E-03 -1.15E-03 -1.43E-03 3.92E-05 -1.32E-03 -1.54E-03 -2.00E-03 PASS -1.49E-03 1.78E-05 -1.44E-03 -1.54E-03 -2.00E-03 PASS -1.43E-03 1.74E-05 -1.39E-03 -1.48E-03 -2.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 104 -1.33E-03 2.04E-05 -1.28E-03 -1.39E-03 -2.00E-03 PASS -1.09E-03 2.76E-05 -1.02E-03 -1.17E-03 -2.00E-03 NA TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 1 @ +5V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.49. Plot of Offset Voltage 1 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 105 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.49. Raw data for Offset Voltage 1 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Voltage 1 @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -1.01E-04 -9.62E-05 -2.48E-05 -7.79E-05 1.60E-05 -6.66E-05 -5.54E-05 -6.02E-05 -8.40E-05 -2.41E-05 -5.28E-05 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 2/16/2012 20 50 100 200 -8.72E-05 -6.45E-05 -3.69E-05 1.96E-05 -8.65E-05 -6.50E-05 -3.82E-05 1.99E-05 -1.56E-05 -1.63E-06 1.10E-05 4.38E-05 -6.90E-05 -4.70E-05 -2.37E-05 3.16E-05 2.12E-05 3.33E-05 5.80E-05 1.02E-04 -5.43E-05 -2.95E-05 1.01E-05 9.77E-05 -5.00E-05 -3.82E-05 -1.53E-05 5.05E-05 -9.51E-05 -5.19E-05 -2.96E-06 1.16E-04 -7.58E-05 -5.66E-05 -2.98E-05 3.72E-05 -1.82E-05 -3.56E-06 1.48E-05 7.09E-05 -5.31E-05 -5.27E-05 -5.25E-05 -5.33E-05 -5.68E-05 -4.74E-05 -2.90E-05 -5.96E-06 4.33E-05 5.07E-05 4.82E-05 4.33E-05 4.09E-05 3.42E-05 8.22E-05 8.47E-05 8.98E-05 1.06E-04 1.37E-04 -1.96E-04 -1.80E-04 -1.48E-04 -1.18E-04 -5.05E-05 -5.80E-05 2.19E-05 1.88E-06 -1.18E-04 -4.50E-04 PASS 4.50E-04 PASS -5.87E-05 2.89E-05 2.07E-05 -1.38E-04 -6.00E-04 PASS 6.00E-04 PASS -3.59E-05 2.11E-05 2.18E-05 -9.37E-05 -7.50E-04 PASS 7.50E-04 PASS -4.63E-06 1.83E-05 4.56E-05 -5.48E-05 -9.00E-04 PASS 9.00E-04 PASS An ISO 9001:2008 and DSCC Certified Company 106 7.44E-05 3.25E-05 1.64E-04 -1.47E-05 -9.00E-04 NA 9.00E-04 NA TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 2 @ +5V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.50. Plot of Offset Voltage 2 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 107 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.50. Raw data for Offset Voltage 2 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Voltage 2 @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -1.64E-06 -5.04E-05 -6.44E-05 -5.98E-06 -5.50E-05 -4.10E-05 -6.02E-05 5.80E-05 -3.08E-06 -5.63E-05 1.87E-06 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 2/16/2012 20 50 100 200 6.45E-06 2.73E-05 5.64E-05 1.28E-04 -4.29E-05 -2.64E-05 -4.65E-06 5.81E-05 -5.75E-05 -4.59E-05 -2.52E-05 1.80E-05 4.76E-06 2.79E-05 5.76E-05 1.30E-04 -4.50E-05 -2.73E-05 -8.40E-06 4.26E-05 -2.87E-05 -1.47E-05 2.14E-05 9.74E-05 -5.32E-05 -4.10E-05 -1.96E-05 4.24E-05 6.55E-05 7.83E-05 9.07E-05 1.43E-04 3.07E-06 2.37E-05 5.29E-05 1.25E-04 -5.45E-05 -4.23E-05 -1.88E-05 4.75E-05 1.63E-06 1.75E-06 1.14E-06 1.14E-06 -3.55E-05 -2.68E-05 -8.88E-06 1.52E-05 7.54E-05 2.94E-05 3.02E-05 3.42E-05 3.90E-05 5.11E-05 4.51E-05 5.58E-05 8.50E-05 1.22E-04 2.15E-04 -1.16E-04 -1.10E-04 -1.03E-04 -9.18E-05 -6.46E-05 -2.05E-05 4.94E-05 1.15E-04 -1.56E-04 -4.50E-04 PASS 4.50E-04 PASS -1.36E-05 5.00E-05 1.24E-04 -1.51E-04 -6.00E-04 PASS 6.00E-04 PASS 8.06E-07 5.09E-05 1.40E-04 -1.39E-04 -7.50E-04 PASS 7.50E-04 PASS 2.53E-05 4.75E-05 1.56E-04 -1.05E-04 -9.00E-04 PASS 9.00E-04 PASS An ISO 9001:2008 and DSCC Certified Company 108 9.10E-05 4.51E-05 2.15E-04 -3.26E-05 -9.00E-04 NA 9.00E-04 NA TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 3 @ +5V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.51. Plot of Offset Voltage 3 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 109 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.51. Raw data for Offset Voltage 3 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Voltage 3 @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -4.10E-05 -7.35E-05 -3.07E-07 -7.35E-05 -8.66E-05 -2.08E-05 -6.18E-05 -9.10E-05 -4.50E-05 -8.07E-05 -4.04E-05 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -2.34E-05 -7.55E-06 2.37E-05 -5.90E-05 -4.53E-05 -2.80E-05 8.63E-06 2.48E-05 4.83E-05 -6.19E-05 -4.59E-05 -2.51E-05 -7.37E-05 -6.16E-05 -3.94E-05 -1.29E-05 8.99E-06 3.76E-05 -5.75E-05 -4.20E-05 -2.48E-05 -8.29E-05 -7.37E-05 -5.58E-05 -3.79E-05 -2.44E-05 -9.11E-07 -7.52E-05 -6.75E-05 -4.41E-05 -4.05E-05 -4.01E-05 -4.09E-05 2/16/2012 200 1.08E-04 1.32E-05 9.82E-05 2.50E-05 1.99E-06 1.26E-04 2.92E-05 -1.07E-05 6.20E-05 -6.67E-07 -3.98E-05 -5.50E-05 -4.19E-05 -2.71E-05 -4.07E-06 4.92E-05 3.49E-05 3.39E-05 3.52E-05 3.80E-05 4.98E-05 4.07E-05 5.11E-05 6.94E-05 1.00E-04 1.86E-04 -1.51E-04 -1.35E-04 -1.24E-04 -1.08E-04 -8.73E-05 -5.98E-05 2.81E-05 1.71E-05 -1.37E-04 -4.50E-04 PASS 4.50E-04 PASS -5.33E-05 2.85E-05 2.48E-05 -1.31E-04 -6.00E-04 PASS 6.00E-04 PASS -3.97E-05 3.37E-05 5.26E-05 -1.32E-04 -7.50E-04 PASS 7.50E-04 PASS -1.76E-05 3.72E-05 8.45E-05 -1.20E-04 -9.00E-04 PASS 9.00E-04 PASS An ISO 9001:2008 and DSCC Certified Company 110 4.12E-05 5.54E-05 1.93E-04 -1.11E-04 -9.00E-04 NA 9.00E-04 NA TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-03 Offset Voltage 4 @ +5V (V) 8.00E-04 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.52. Plot of Offset Voltage 4 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 111 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.52. Raw data for Offset Voltage 4 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Voltage 4 @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -9.41E-05 -4.04E-05 -2.16E-05 -1.83E-05 -5.48E-07 2.19E-05 -5.50E-06 -4.92E-05 -4.22E-05 3.92E-06 3.89E-05 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 2/16/2012 20 50 100 200 -8.45E-05 -6.79E-05 -5.08E-05 8.51E-06 -3.47E-05 -1.66E-05 4.64E-06 5.76E-05 -1.38E-05 3.44E-06 2.06E-05 5.40E-05 -5.14E-06 1.36E-05 3.97E-05 1.07E-04 8.75E-06 2.48E-05 4.61E-05 8.13E-05 2.96E-05 4.77E-05 8.54E-05 1.78E-04 -2.19E-05 1.25E-05 5.08E-05 1.28E-04 -4.10E-05 -2.20E-05 1.18E-05 8.76E-05 -3.34E-05 -1.72E-05 1.14E-05 8.87E-05 1.36E-05 3.01E-05 5.03E-05 1.26E-04 3.91E-05 3.86E-05 3.88E-05 3.82E-05 -3.50E-05 -2.59E-05 -8.54E-06 1.20E-05 6.18E-05 3.60E-05 3.63E-05 3.65E-05 3.87E-05 3.67E-05 6.36E-05 7.38E-05 9.16E-05 1.18E-04 1.62E-04 -1.34E-04 -1.26E-04 -1.09E-04 -9.41E-05 -3.88E-05 -1.42E-05 3.05E-05 6.94E-05 -9.78E-05 -4.50E-04 PASS 4.50E-04 PASS -1.06E-05 3.07E-05 7.36E-05 -9.48E-05 -6.00E-04 PASS 6.00E-04 PASS 1.02E-05 3.00E-05 9.25E-05 -7.21E-05 -7.50E-04 PASS 7.50E-04 PASS 4.19E-05 1.22E-04 3.11E-05 3.71E-05 1.27E-04 2.24E-04 -4.35E-05 2.00E-05 -9.00E-04 -9.00E-04 PASS NA 9.00E-04 9.00E-04 PASS NA An ISO 9001:2008 and DSCC Certified Company 112 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.50E-08 Offset Current 1 @ +5V (A) 2.00E-08 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 -2.50E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.53. Plot of Offset Current 1 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 113 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.53. Raw data for Offset Current 1 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Current 1 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 2.20E-11 3.20E-11 5.90E-11 4.30E-11 2.00E-12 1.20E-11 -5.90E-11 -2.00E-12 -3.50E-11 -1.70E-11 3.80E-11 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -3.00E-12 -9.60E-11 4.30E-11 8.00E-11 1.27E-10 7.20E-11 1.00E-12 3.30E-11 1.15E-10 1.40E-11 6.20E-11 1.29E-10 6.90E-11 1.41E-10 4.80E-11 2.80E-11 3.90E-11 5.20E-11 -4.70E-11 -1.70E-10 -4.36E-10 -3.60E-11 -9.30E-11 -1.20E-10 -1.05E-10 -1.74E-10 -2.41E-10 -9.50E-11 -2.61E-10 -4.61E-10 5.00E-11 4.70E-11 3.70E-11 2/16/2012 200 1.87E-10 1.24E-10 6.87E-10 3.40E-10 -1.20E-10 1.69E-10 -1.17E-09 3.80E-11 -2.94E-10 -1.09E-09 5.10E-11 3.16E-11 3.22E-11 5.34E-11 8.14E-11 2.44E-10 2.15E-11 3.93E-11 9.47E-11 3.90E-11 2.98E-10 9.06E-11 1.40E-10 3.13E-10 1.88E-10 1.06E-09 -2.74E-11 -7.56E-11 -2.06E-10 -2.54E-11 -5.74E-10 -2.02E-11 2.79E-11 5.62E-11 -9.66E-11 -1.00E-08 PASS 1.00E-08 PASS -5.10E-11 5.32E-11 9.50E-11 -1.97E-10 -1.00E-08 PASS 1.00E-08 PASS -1.32E-10 1.12E-10 1.77E-10 -4.40E-10 -1.50E-08 PASS 1.50E-08 PASS -2.41E-10 2.16E-10 3.52E-10 -8.34E-10 -2.00E-08 PASS 2.00E-08 PASS An ISO 9001:2008 and DSCC Certified Company 114 -4.69E-10 6.26E-10 1.25E-09 -2.19E-09 -2.00E-08 NA 2.00E-08 NA TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.50E-08 Offset Current 2 @ +5V (A) 2.00E-08 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 -2.50E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.54. Plot of Offset Current 2 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 115 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.54. Raw data for Offset Current 2 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Current 2 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -1.90E-11 -1.10E-11 -1.10E-10 1.40E-11 5.00E-12 -8.00E-12 3.30E-11 -1.50E-11 -2.10E-11 -1.05E-10 -3.50E-11 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -4.70E-11 -9.40E-11 -8.20E-11 -8.60E-11 2.40E-11 9.20E-11 8.00E-12 -2.00E-12 2.40E-11 -2.00E-11 -7.30E-11 -9.70E-11 3.90E-11 7.00E-11 -1.00E-12 1.00E-12 5.80E-11 -6.40E-11 -1.20E-11 -6.90E-11 -1.06E-10 -8.40E-11 -8.90E-11 -8.00E-11 6.60E-11 -5.40E-11 -4.70E-11 -8.70E-11 -1.57E-10 -1.85E-10 -4.70E-11 -5.10E-11 -4.60E-11 2/16/2012 200 9.60E-11 2.37E-10 2.88E-10 -2.04E-10 -3.60E-11 2.42E-10 -1.07E-09 -9.63E-10 -4.38E-10 -3.51E-10 -4.90E-11 -2.42E-11 -2.12E-11 -1.50E-11 -1.28E-11 7.62E-11 4.97E-11 4.83E-11 6.80E-11 7.80E-11 2.01E-10 1.12E-10 1.11E-10 1.72E-10 2.01E-10 6.28E-10 -1.60E-10 -1.54E-10 -2.02E-10 -2.27E-10 -4.76E-10 -2.32E-11 5.04E-11 1.15E-10 -1.61E-10 -1.00E-08 PASS 1.00E-08 PASS -2.32E-11 6.41E-11 1.53E-10 -1.99E-10 -1.00E-08 PASS 1.00E-08 PASS -6.22E-11 7.79E-11 1.51E-10 -2.76E-10 -1.50E-08 PASS 1.50E-08 PASS -9.64E-11 5.41E-11 5.19E-11 -2.45E-10 -2.00E-08 PASS 2.00E-08 PASS An ISO 9001:2008 and DSCC Certified Company 116 -5.15E-10 5.27E-10 9.29E-10 -1.96E-09 -2.00E-08 NA 2.00E-08 NA TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.50E-08 Offset Current 3 @ +5V (A) 2.00E-08 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 -2.50E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.55. Plot of Offset Current 3 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 117 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.55. Raw data for Offset Current 3 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Current 3 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -1.22E-10 4.20E-11 3.10E-11 7.00E-11 -2.90E-11 -1.29E-10 4.00E-12 -1.73E-10 -3.60E-11 -1.10E-11 -4.60E-11 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -1.50E-10 -1.23E-10 -1.16E-10 1.15E-10 4.40E-11 2.15E-10 -5.50E-11 -6.20E-11 -3.80E-11 -5.80E-11 -1.06E-10 -9.70E-11 2.30E-11 -4.00E-12 -1.29E-10 8.00E-12 -1.20E-11 -6.90E-11 -4.10E-11 -1.23E-10 -2.97E-10 -3.37E-10 -3.01E-10 -6.13E-10 -3.90E-11 -1.70E-11 5.50E-11 1.40E-11 6.20E-11 2.43E-10 -5.70E-11 -4.40E-11 -8.20E-11 2/16/2012 200 9.80E-11 6.16E-10 4.64E-10 1.60E-11 -6.20E-11 5.90E-11 -1.37E-09 -1.27E-09 -9.40E-11 3.18E-10 -5.70E-11 -1.60E-12 -2.50E-11 -5.02E-11 -3.30E-11 2.26E-10 7.64E-11 9.94E-11 6.99E-11 1.43E-10 2.97E-10 2.08E-10 2.48E-10 1.42E-10 3.59E-10 1.04E-09 -2.11E-10 -2.98E-10 -2.42E-10 -4.25E-10 -5.87E-10 -6.90E-11 7.78E-11 1.44E-10 -2.82E-10 -1.00E-08 PASS 1.00E-08 PASS -7.90E-11 1.46E-10 3.23E-10 -4.81E-10 -1.00E-08 PASS 1.00E-08 PASS -7.82E-11 1.41E-10 3.08E-10 -4.65E-10 -1.50E-08 PASS 1.50E-08 PASS -1.36E-10 3.31E-10 7.71E-10 -1.04E-09 -2.00E-08 PASS 2.00E-08 PASS An ISO 9001:2008 and DSCC Certified Company 118 -4.70E-10 7.88E-10 1.69E-09 -2.63E-09 -2.00E-08 NA 2.00E-08 NA TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.50E-08 Offset Current 4 @ +5V (A) 2.00E-08 1.50E-08 1.00E-08 5.00E-09 0.00E+00 -5.00E-09 -1.00E-08 -1.50E-08 -2.00E-08 -2.50E-08 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.56. Plot of Offset Current 4 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or postirradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 119 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.56. Raw data for Offset Current 4 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Offset Current 4 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 2/6/2012 0 -3.60E-11 3.80E-11 3.00E-11 -5.00E-11 -5.00E-12 -6.00E-11 3.10E-11 -9.40E-11 -3.20E-11 -1.56E-10 -9.70E-11 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 -1.19E-10 -1.51E-10 -8.90E-11 6.90E-11 5.80E-11 7.30E-11 5.70E-11 7.50E-11 1.58E-10 -8.70E-11 -1.96E-10 -3.00E-12 0.00E+00 -1.94E-10 -2.41E-10 -9.60E-11 -8.30E-11 -8.60E-11 -1.46E-10 -2.79E-10 -6.89E-10 -2.17E-10 -2.01E-10 -2.46E-10 -1.15E-10 -1.23E-10 -3.18E-10 -2.49E-10 -4.20E-10 -5.85E-10 -9.40E-11 -1.06E-10 -1.13E-10 2/16/2012 200 -1.19E-10 4.40E-10 9.11E-10 3.05E-10 -2.54E-10 3.30E-11 -1.37E-09 1.73E-10 -2.64E-10 -1.04E-09 -8.30E-11 -4.60E-12 -1.60E-11 -8.16E-11 -2.04E-11 2.57E-10 3.89E-11 8.44E-11 1.37E-10 1.53E-10 4.65E-10 1.02E-10 2.15E-10 2.93E-10 4.00E-10 1.53E-09 -1.11E-10 -2.47E-10 -4.56E-10 -4.41E-10 -1.02E-09 -6.22E-11 6.97E-11 1.29E-10 -2.53E-10 -1.00E-08 PASS 1.00E-08 PASS -1.65E-10 6.59E-11 1.61E-11 -3.45E-10 -1.00E-08 PASS 1.00E-08 PASS -2.21E-10 1.34E-10 1.47E-10 -5.89E-10 -1.50E-08 PASS 1.50E-08 PASS -3.85E-10 2.48E-10 2.95E-10 -1.06E-09 -2.00E-08 PASS 2.00E-08 PASS An ISO 9001:2008 and DSCC Certified Company 120 -4.93E-10 6.77E-10 1.36E-09 -2.35E-09 -2.00E-08 NA 2.00E-08 NA TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 1 @ +5V (A) 2.50E-07 2.00E-07 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 -2.00E-07 -2.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.57. Plot of Positive Bias Current 1 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 121 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.57. Raw data for Positive Bias Current 1 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Bias Current 1 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.15E-08 1.47E-08 2.10E-08 2.93E-08 4.86E-08 1.18E-08 1.46E-08 2.09E-08 2.91E-08 4.82E-08 1.09E-08 1.41E-08 2.05E-08 2.84E-08 4.66E-08 1.24E-08 1.60E-08 2.29E-08 3.13E-08 5.11E-08 1.13E-08 1.44E-08 2.07E-08 2.89E-08 4.83E-08 1.13E-08 1.39E-08 1.94E-08 2.65E-08 4.32E-08 1.14E-08 1.44E-08 2.06E-08 2.89E-08 4.77E-08 1.18E-08 1.45E-08 2.04E-08 2.76E-08 4.53E-08 1.13E-08 1.46E-08 2.04E-08 2.82E-08 4.68E-08 1.15E-08 1.48E-08 2.11E-08 2.91E-08 4.86E-08 1.11E-08 1.10E-08 1.11E-08 1.10E-08 1.11E-08 1.16E-08 5.55E-10 1.31E-08 1.00E-08 1.48E-08 7.23E-10 1.67E-08 1.28E-08 2.12E-08 9.55E-10 2.38E-08 1.86E-08 2.94E-08 1.11E-09 3.25E-08 2.63E-08 4.86E-08 1.62E-09 5.30E-08 4.41E-08 1.14E-08 1.44E-08 2.04E-08 2.80E-08 4.63E-08 2.10E-10 3.21E-10 6.24E-10 1.05E-09 2.15E-09 1.20E-08 1.53E-08 2.21E-08 3.09E-08 5.22E-08 1.09E-08 1.36E-08 1.87E-08 2.52E-08 4.04E-08 -5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07 PASS PASS PASS PASS NA 5.00E-08 1.00E-07 1.25E-07 2.00E-07 2.00E-07 PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 122 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 2 @ +5V (A) 2.50E-07 2.00E-07 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 -2.00E-07 -2.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.58. Plot of Positive Bias Current 2 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 123 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.58. Raw data for Positive Bias Current 2 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Bias Current 2 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.26E-08 1.58E-08 2.23E-08 3.04E-08 5.07E-08 1.23E-08 1.53E-08 2.16E-08 2.98E-08 4.95E-08 1.13E-08 1.45E-08 2.08E-08 2.83E-08 4.65E-08 1.27E-08 1.64E-08 2.33E-08 3.17E-08 5.20E-08 1.28E-08 1.60E-08 2.32E-08 3.18E-08 5.36E-08 1.17E-08 1.46E-08 2.02E-08 2.80E-08 4.52E-08 1.18E-08 1.50E-08 2.16E-08 3.06E-08 5.08E-08 1.15E-08 1.48E-08 2.12E-08 2.94E-08 4.94E-08 1.15E-08 1.49E-08 2.11E-08 2.96E-08 4.92E-08 1.12E-08 1.43E-08 2.07E-08 2.89E-08 4.82E-08 1.19E-08 1.19E-08 1.19E-08 1.19E-08 1.19E-08 1.24E-08 6.05E-10 1.40E-08 1.07E-08 1.56E-08 7.27E-10 1.76E-08 1.36E-08 2.22E-08 1.07E-09 2.51E-08 1.93E-08 3.04E-08 1.45E-09 3.44E-08 2.64E-08 5.04E-08 2.69E-09 5.78E-08 4.31E-08 1.16E-08 1.47E-08 2.10E-08 2.93E-08 4.86E-08 2.62E-10 2.79E-10 5.49E-10 9.85E-10 2.11E-09 1.23E-08 1.55E-08 2.25E-08 3.20E-08 5.44E-08 1.08E-08 1.40E-08 1.95E-08 2.66E-08 4.28E-08 -5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07 PASS PASS PASS PASS NA 5.00E-08 1.00E-07 1.25E-07 2.00E-07 2.00E-07 PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 124 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 3 @ +5V (A) 2.50E-07 2.00E-07 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 -2.00E-07 -2.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.59. Plot of Positive Bias Current 3 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 125 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.59. Raw data for Positive Bias Current 3 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Bias Current 3 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.20E-08 1.52E-08 2.14E-08 2.92E-08 4.89E-08 1.18E-08 1.47E-08 2.09E-08 2.87E-08 4.76E-08 1.09E-08 1.41E-08 2.04E-08 2.78E-08 4.54E-08 1.16E-08 1.52E-08 2.17E-08 2.95E-08 4.85E-08 1.25E-08 1.56E-08 2.26E-08 3.08E-08 5.16E-08 1.19E-08 1.46E-08 2.04E-08 2.80E-08 4.52E-08 1.16E-08 1.46E-08 2.10E-08 2.97E-08 4.92E-08 1.18E-08 1.52E-08 2.16E-08 3.01E-08 5.00E-08 1.10E-08 1.44E-08 2.02E-08 2.84E-08 4.71E-08 1.02E-08 1.31E-08 1.89E-08 2.66E-08 4.44E-08 1.15E-08 1.15E-08 1.15E-08 1.15E-08 1.15E-08 1.18E-08 5.90E-10 1.34E-08 1.01E-08 1.49E-08 5.64E-10 1.65E-08 1.34E-08 2.14E-08 8.32E-10 2.37E-08 1.91E-08 2.92E-08 1.12E-09 3.23E-08 2.61E-08 4.84E-08 2.23E-09 5.45E-08 4.23E-08 1.13E-08 1.44E-08 2.04E-08 2.86E-08 4.72E-08 6.99E-10 7.70E-10 9.91E-10 1.41E-09 2.44E-09 1.32E-08 1.65E-08 2.31E-08 3.24E-08 5.39E-08 9.37E-09 1.22E-08 1.77E-08 2.47E-08 4.05E-08 -5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07 PASS PASS PASS PASS NA 5.00E-08 1.00E-07 1.25E-07 2.00E-07 2.00E-07 PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 126 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Positive Bias Current 4 @ +5V (A) 2.50E-07 2.00E-07 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 -2.00E-07 -2.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.60. Plot of Positive Bias Current 4 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 127 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.60. Raw data for Positive Bias Current 4 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Bias Current 4 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.21E-08 1.53E-08 2.18E-08 3.02E-08 5.03E-08 1.22E-08 1.52E-08 2.16E-08 3.00E-08 4.94E-08 1.12E-08 1.46E-08 2.13E-08 2.94E-08 4.80E-08 1.28E-08 1.65E-08 2.36E-08 3.21E-08 5.22E-08 1.18E-08 1.50E-08 2.17E-08 3.01E-08 5.01E-08 1.24E-08 1.54E-08 2.13E-08 2.91E-08 4.70E-08 1.18E-08 1.50E-08 2.15E-08 3.00E-08 4.96E-08 1.22E-08 1.53E-08 2.13E-08 2.89E-08 4.68E-08 1.17E-08 1.50E-08 2.12E-08 2.92E-08 4.82E-08 1.20E-08 1.53E-08 2.17E-08 2.98E-08 4.95E-08 1.21E-08 1.21E-08 1.21E-08 1.21E-08 1.21E-08 1.20E-08 5.86E-10 1.36E-08 1.04E-08 1.53E-08 7.28E-10 1.73E-08 1.33E-08 2.20E-08 9.19E-10 2.45E-08 1.95E-08 3.04E-08 1.03E-09 3.32E-08 2.75E-08 5.00E-08 1.51E-09 5.42E-08 4.59E-08 1.20E-08 1.52E-08 2.14E-08 2.94E-08 4.82E-08 2.77E-10 1.67E-10 2.09E-10 4.95E-10 1.32E-09 1.28E-08 1.57E-08 2.20E-08 3.07E-08 5.18E-08 1.13E-08 1.47E-08 2.08E-08 2.80E-08 4.46E-08 -5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07 PASS PASS PASS PASS NA 5.00E-08 1.00E-07 1.25E-07 2.00E-07 2.00E-07 PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 128 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 1 @ +5V (A) 2.50E-07 2.00E-07 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 -2.00E-07 -2.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.61. Plot of Negative Bias Current 1 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 129 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.61. Raw data for Negative Bias Current 1 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Bias Current 1 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.16E-08 1.47E-08 2.09E-08 2.93E-08 4.89E-08 1.18E-08 1.47E-08 2.09E-08 2.92E-08 4.84E-08 1.10E-08 1.41E-08 2.05E-08 2.86E-08 4.74E-08 1.24E-08 1.60E-08 2.29E-08 3.15E-08 5.15E-08 1.13E-08 1.44E-08 2.09E-08 2.90E-08 4.82E-08 1.12E-08 1.39E-08 1.95E-08 2.65E-08 4.34E-08 1.14E-08 1.44E-08 2.04E-08 2.84E-08 4.66E-08 1.17E-08 1.45E-08 2.03E-08 2.76E-08 4.55E-08 1.13E-08 1.44E-08 2.02E-08 2.80E-08 4.66E-08 1.16E-08 1.47E-08 2.08E-08 2.86E-08 4.77E-08 1.11E-08 1.11E-08 1.11E-08 1.11E-08 1.11E-08 1.16E-08 5.34E-10 1.31E-08 1.01E-08 1.48E-08 7.02E-10 1.67E-08 1.28E-08 2.12E-08 9.68E-10 2.39E-08 1.86E-08 2.95E-08 1.15E-09 3.27E-08 2.64E-08 4.89E-08 1.57E-09 5.32E-08 4.46E-08 1.14E-08 1.44E-08 2.02E-08 2.78E-08 4.59E-08 2.07E-10 2.89E-10 4.97E-10 8.29E-10 1.61E-09 1.20E-08 1.52E-08 2.16E-08 3.01E-08 5.04E-08 1.09E-08 1.36E-08 1.89E-08 2.55E-08 4.15E-08 -5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07 PASS PASS PASS PASS NA 5.00E-08 1.00E-07 1.25E-07 2.00E-07 2.00E-07 PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 130 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 2 @ +5V (A) 2.50E-07 2.00E-07 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 -2.00E-07 -2.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.62. Plot of Negative Bias Current 2 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 131 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.62. Raw data for Negative Bias Current 2 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Bias Current 2 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.25E-08 1.57E-08 2.22E-08 3.03E-08 5.08E-08 1.23E-08 1.52E-08 2.16E-08 3.00E-08 4.98E-08 1.13E-08 1.45E-08 2.08E-08 2.84E-08 4.69E-08 1.27E-08 1.64E-08 2.32E-08 3.16E-08 5.18E-08 1.28E-08 1.61E-08 2.32E-08 3.19E-08 5.36E-08 1.17E-08 1.45E-08 2.03E-08 2.79E-08 4.54E-08 1.19E-08 1.50E-08 2.15E-08 3.05E-08 4.98E-08 1.15E-08 1.47E-08 2.11E-08 2.93E-08 4.85E-08 1.15E-08 1.50E-08 2.11E-08 2.96E-08 4.88E-08 1.11E-08 1.43E-08 2.05E-08 2.88E-08 4.78E-08 1.18E-08 1.18E-08 1.18E-08 1.18E-08 1.18E-08 1.23E-08 6.26E-10 1.40E-08 1.06E-08 1.56E-08 7.41E-10 1.76E-08 1.35E-08 2.22E-08 1.05E-09 2.51E-08 1.94E-08 3.04E-08 1.41E-09 3.43E-08 2.66E-08 5.06E-08 2.50E-09 5.74E-08 4.37E-08 1.15E-08 1.47E-08 2.09E-08 2.92E-08 4.81E-08 2.75E-10 3.11E-10 5.26E-10 9.74E-10 1.65E-09 1.23E-08 1.55E-08 2.23E-08 3.19E-08 5.26E-08 1.08E-08 1.38E-08 1.95E-08 2.66E-08 4.35E-08 -5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07 PASS PASS PASS PASS NA 5.00E-08 1.00E-07 1.25E-07 2.00E-07 2.00E-07 PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 132 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 3 @ +5V (A) 2.50E-07 2.00E-07 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 -2.00E-07 -2.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.63. Plot of Negative Bias Current 3 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 133 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.63. Raw data for Negative Bias Current 3 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Bias Current 3 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.18E-08 1.50E-08 2.13E-08 2.92E-08 4.91E-08 1.18E-08 1.48E-08 2.09E-08 2.89E-08 4.82E-08 1.09E-08 1.41E-08 2.02E-08 2.77E-08 4.59E-08 1.17E-08 1.51E-08 2.16E-08 2.93E-08 4.85E-08 1.24E-08 1.56E-08 2.26E-08 3.07E-08 5.16E-08 1.18E-08 1.46E-08 2.04E-08 2.80E-08 4.53E-08 1.16E-08 1.45E-08 2.09E-08 2.95E-08 4.80E-08 1.16E-08 1.48E-08 2.13E-08 2.95E-08 4.88E-08 1.10E-08 1.43E-08 2.03E-08 2.84E-08 4.71E-08 1.01E-08 1.31E-08 1.89E-08 2.68E-08 4.47E-08 1.14E-08 1.15E-08 1.15E-08 1.15E-08 1.15E-08 1.17E-08 5.69E-10 1.33E-08 1.02E-08 1.49E-08 5.59E-10 1.64E-08 1.34E-08 2.13E-08 8.54E-10 2.37E-08 1.90E-08 2.92E-08 1.10E-09 3.22E-08 2.62E-08 4.87E-08 2.03E-09 5.42E-08 4.31E-08 1.12E-08 1.43E-08 2.03E-08 2.85E-08 4.68E-08 6.68E-10 6.86E-10 9.09E-10 1.13E-09 1.74E-09 1.31E-08 1.62E-08 2.28E-08 3.16E-08 5.15E-08 9.39E-09 1.24E-08 1.79E-08 2.54E-08 4.20E-08 -5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07 PASS PASS PASS PASS NA 5.00E-08 1.00E-07 1.25E-07 2.00E-07 2.00E-07 PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 134 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX Negative Bias Current 4 @ +5V (A) 2.50E-07 2.00E-07 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 -2.00E-07 -2.50E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.64. Plot of Negative Bias Current 4 @ +5V (A) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 135 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.64. Raw data for Negative Bias Current 4 @ +5V (A) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Bias Current 4 @ +5V (A) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 0 20 50 100 200 1.20E-08 1.52E-08 2.17E-08 3.01E-08 5.02E-08 1.22E-08 1.52E-08 2.16E-08 3.01E-08 4.99E-08 1.12E-08 1.47E-08 2.13E-08 2.95E-08 4.90E-08 1.27E-08 1.64E-08 2.35E-08 3.22E-08 5.25E-08 1.17E-08 1.49E-08 2.15E-08 2.99E-08 4.99E-08 1.23E-08 1.53E-08 2.13E-08 2.91E-08 4.70E-08 1.19E-08 1.49E-08 2.12E-08 2.93E-08 4.82E-08 1.22E-08 1.51E-08 2.11E-08 2.86E-08 4.70E-08 1.16E-08 1.49E-08 2.11E-08 2.89E-08 4.80E-08 1.18E-08 1.51E-08 2.13E-08 2.93E-08 4.85E-08 1.20E-08 1.20E-08 1.20E-08 1.20E-08 1.20E-08 1.20E-08 5.67E-10 1.35E-08 1.04E-08 1.53E-08 6.79E-10 1.72E-08 1.34E-08 2.19E-08 8.67E-10 2.43E-08 1.96E-08 3.04E-08 1.06E-09 3.33E-08 2.75E-08 5.03E-08 1.31E-09 5.39E-08 4.67E-08 1.20E-08 1.50E-08 2.12E-08 2.90E-08 4.78E-08 2.74E-10 1.77E-10 9.94E-11 2.81E-10 7.13E-10 1.27E-08 1.55E-08 2.15E-08 2.98E-08 4.97E-08 1.12E-08 1.46E-08 2.09E-08 2.83E-08 4.58E-08 -5.00E-08 -1.00E-07 -1.25E-07 -2.00E-07 -2.00E-07 PASS PASS PASS PASS NA 5.00E-08 1.00E-07 1.25E-07 2.00E-07 2.00E-07 PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 136 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 1 RL=open @ +5V (V) 4.35E+00 4.30E+00 4.25E+00 4.20E+00 4.15E+00 4.10E+00 4.05E+00 4.00E+00 3.95E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.65. Plot of Positive Output Voltage 1 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 137 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.65. Raw data for Positive Output Voltage 1 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 1 RL=open @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 4.29E+00 4.28E+00 4.29E+00 4.29E+00 4.28E+00 4.28E+00 4.29E+00 4.27E+00 4.29E+00 4.29E+00 4.28E+00 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 4.28E+00 4.28E+00 4.30E+00 4.28E+00 4.28E+00 4.30E+00 4.28E+00 4.29E+00 4.31E+00 4.28E+00 4.28E+00 4.30E+00 4.28E+00 4.28E+00 4.30E+00 4.27E+00 4.27E+00 4.29E+00 4.27E+00 4.28E+00 4.29E+00 4.27E+00 4.28E+00 4.29E+00 4.27E+00 4.28E+00 4.29E+00 4.27E+00 4.28E+00 4.29E+00 4.28E+00 4.28E+00 4.28E+00 2/16/2012 200 4.33E+00 4.32E+00 4.32E+00 4.32E+00 4.32E+00 4.32E+00 4.33E+00 4.32E+00 4.33E+00 4.33E+00 4.28E+00 4.29E+00 4.28E+00 4.28E+00 4.30E+00 4.32E+00 3.81E-03 1.67E-03 3.36E-03 5.37E-03 2.12E-03 4.30E+00 4.28E+00 4.29E+00 4.32E+00 4.33E+00 4.27E+00 4.27E+00 4.27E+00 4.29E+00 4.32E+00 4.28E+00 6.78E-03 4.30E+00 4.26E+00 4.00E+00 PASS 4.27E+00 2.92E-03 4.28E+00 4.26E+00 4.00E+00 PASS 4.28E+00 3.05E-03 4.28E+00 4.27E+00 4.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 138 4.29E+00 3.11E-03 4.30E+00 4.28E+00 4.00E+00 PASS 4.33E+00 5.10E-03 4.34E+00 4.31E+00 4.00E+00 NA TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 2 RL=open @ +5V (V) 4.35E+00 4.30E+00 4.25E+00 4.20E+00 4.15E+00 4.10E+00 4.05E+00 4.00E+00 3.95E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.66. Plot of Positive Output Voltage 2 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 139 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.66. Raw data for Positive Output Voltage 2 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 2 RL=open @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 4.27E+00 4.27E+00 4.27E+00 4.27E+00 4.26E+00 4.27E+00 4.28E+00 4.27E+00 4.28E+00 4.27E+00 4.27E+00 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 4.26E+00 4.27E+00 4.28E+00 4.26E+00 4.26E+00 4.28E+00 4.26E+00 4.27E+00 4.28E+00 4.26E+00 4.27E+00 4.28E+00 4.26E+00 4.27E+00 4.28E+00 4.26E+00 4.26E+00 4.27E+00 4.26E+00 4.27E+00 4.28E+00 4.26E+00 4.27E+00 4.28E+00 4.27E+00 4.27E+00 4.28E+00 4.26E+00 4.27E+00 4.28E+00 4.27E+00 4.27E+00 4.27E+00 2/16/2012 200 4.32E+00 4.32E+00 4.32E+00 4.32E+00 4.33E+00 4.32E+00 4.33E+00 4.33E+00 4.33E+00 4.33E+00 4.27E+00 4.27E+00 4.26E+00 4.27E+00 4.28E+00 4.32E+00 4.47E-03 2.00E-03 1.92E-03 2.74E-03 2.35E-03 4.28E+00 4.27E+00 4.27E+00 4.29E+00 4.33E+00 4.26E+00 4.26E+00 4.26E+00 4.27E+00 4.32E+00 4.27E+00 3.91E-03 4.28E+00 4.26E+00 4.00E+00 PASS 4.26E+00 3.21E-03 4.27E+00 4.25E+00 4.00E+00 PASS 4.27E+00 3.27E-03 4.28E+00 4.26E+00 4.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 140 4.28E+00 4.32E-03 4.29E+00 4.27E+00 4.00E+00 PASS 4.33E+00 3.96E-03 4.34E+00 4.32E+00 4.00E+00 NA TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 3 RL=open @ +5V (V) 4.35E+00 4.30E+00 4.25E+00 4.20E+00 4.15E+00 4.10E+00 4.05E+00 4.00E+00 3.95E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.67. Plot of Positive Output Voltage 3 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 141 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.67. Raw data for Positive Output Voltage 3 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 3 RL=open @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 4.29E+00 4.28E+00 4.28E+00 4.29E+00 4.28E+00 4.28E+00 4.29E+00 4.28E+00 4.29E+00 4.28E+00 4.29E+00 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 4.27E+00 4.28E+00 4.30E+00 4.27E+00 4.28E+00 4.29E+00 4.28E+00 4.28E+00 4.31E+00 4.27E+00 4.28E+00 4.30E+00 4.28E+00 4.28E+00 4.30E+00 4.27E+00 4.28E+00 4.29E+00 4.28E+00 4.28E+00 4.30E+00 4.28E+00 4.28E+00 4.30E+00 4.27E+00 4.28E+00 4.29E+00 4.27E+00 4.28E+00 4.30E+00 4.29E+00 4.29E+00 4.29E+00 2/16/2012 200 4.32E+00 4.32E+00 4.32E+00 4.32E+00 4.33E+00 4.32E+00 4.33E+00 4.33E+00 4.33E+00 4.33E+00 4.29E+00 4.28E+00 4.27E+00 4.28E+00 4.30E+00 4.32E+00 4.51E-03 2.95E-03 2.86E-03 4.04E-03 2.30E-03 4.29E+00 4.28E+00 4.29E+00 4.31E+00 4.33E+00 4.27E+00 4.27E+00 4.27E+00 4.29E+00 4.32E+00 4.28E+00 3.03E-03 4.29E+00 4.27E+00 4.00E+00 PASS 4.27E+00 3.03E-03 4.28E+00 4.26E+00 4.00E+00 PASS 4.28E+00 3.42E-03 4.29E+00 4.27E+00 4.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 142 4.30E+00 4.49E-03 4.31E+00 4.28E+00 4.00E+00 PASS 4.33E+00 4.21E-03 4.34E+00 4.32E+00 4.00E+00 NA TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 4 RL=open @ +5V (V) 4.35E+00 4.30E+00 4.25E+00 4.20E+00 4.15E+00 4.10E+00 4.05E+00 4.00E+00 3.95E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.68. Plot of Positive Output Voltage 4 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 143 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.68. Raw data for Positive Output Voltage 4 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 4 RL=open @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 4.28E+00 4.27E+00 4.27E+00 4.27E+00 4.27E+00 4.27E+00 4.27E+00 4.26E+00 4.28E+00 4.27E+00 4.27E+00 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 4.27E+00 4.27E+00 4.28E+00 4.26E+00 4.26E+00 4.28E+00 4.27E+00 4.27E+00 4.28E+00 4.27E+00 4.27E+00 4.28E+00 4.27E+00 4.27E+00 4.28E+00 4.26E+00 4.26E+00 4.27E+00 4.26E+00 4.27E+00 4.28E+00 4.26E+00 4.26E+00 4.28E+00 4.26E+00 4.27E+00 4.28E+00 4.26E+00 4.27E+00 4.28E+00 4.27E+00 4.27E+00 4.27E+00 2/16/2012 200 4.33E+00 4.32E+00 4.32E+00 4.32E+00 4.33E+00 4.32E+00 4.33E+00 4.32E+00 4.33E+00 4.33E+00 4.27E+00 4.27E+00 4.27E+00 4.27E+00 4.28E+00 4.32E+00 3.56E-03 1.87E-03 2.77E-03 2.83E-03 2.07E-03 4.28E+00 4.27E+00 4.28E+00 4.29E+00 4.33E+00 4.26E+00 4.26E+00 4.26E+00 4.27E+00 4.32E+00 4.27E+00 5.54E-03 4.29E+00 4.26E+00 4.00E+00 PASS 4.26E+00 2.39E-03 4.27E+00 4.25E+00 4.00E+00 PASS 4.27E+00 2.24E-03 4.27E+00 4.26E+00 4.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 144 4.28E+00 2.86E-03 4.28E+00 4.27E+00 4.00E+00 PASS 4.33E+00 4.56E-03 4.34E+00 4.32E+00 4.00E+00 NA TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 1 RL=600 @ +5V (V) 4.50E+00 4.00E+00 3.50E+00 3.00E+00 2.50E+00 2.00E+00 1.50E+00 1.00E+00 5.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.69. Plot of Positive Output Voltage 1 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 145 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.69. Raw data for Positive Output Voltage 1 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 1 RL=600 @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 3.84E+00 3.83E+00 3.84E+00 3.84E+00 3.85E+00 3.84E+00 3.85E+00 3.84E+00 3.85E+00 3.85E+00 3.85E+00 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 3.84E+00 3.84E+00 3.84E+00 3.83E+00 3.83E+00 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00 3.83E+00 3.83E+00 3.85E+00 3.85E+00 3.84E+00 3.83E+00 3.83E+00 3.83E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00 3.85E+00 3.84E+00 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 2/16/2012 200 3.83E+00 3.82E+00 3.83E+00 3.82E+00 3.84E+00 3.82E+00 3.84E+00 3.83E+00 3.84E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00 3.83E+00 6.26E-03 6.34E-03 6.58E-03 6.95E-03 7.35E-03 3.86E+00 3.86E+00 3.85E+00 3.85E+00 3.85E+00 3.82E+00 3.82E+00 3.82E+00 3.82E+00 3.81E+00 3.85E+00 7.92E-03 3.87E+00 3.82E+00 3.40E+00 PASS 3.84E+00 8.06E-03 3.87E+00 3.82E+00 3.20E+00 PASS 3.84E+00 8.06E-03 3.86E+00 3.82E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 146 3.84E+00 8.56E-03 3.86E+00 3.82E+00 2.80E+00 PASS 3.84E+00 9.15E-03 3.86E+00 3.81E+00 2.80E+00 NA TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 2 RL=600 @ +5V (V) 4.50E+00 4.00E+00 3.50E+00 3.00E+00 2.50E+00 2.00E+00 1.50E+00 1.00E+00 5.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.70. Plot of Positive Output Voltage 2 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 147 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.70. Raw data for Positive Output Voltage 2 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 2 RL=600 @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 3.84E+00 3.84E+00 3.85E+00 3.85E+00 3.87E+00 3.85E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 3.84E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00 3.86E+00 3.86E+00 3.86E+00 3.84E+00 3.84E+00 3.84E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.86E+00 2/16/2012 200 3.83E+00 3.83E+00 3.84E+00 3.84E+00 3.86E+00 3.83E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.86E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00 9.34E-03 9.72E-03 1.00E-02 1.01E-02 1.05E-02 3.88E+00 3.87E+00 3.87E+00 3.87E+00 3.87E+00 3.82E+00 3.82E+00 3.82E+00 3.82E+00 3.81E+00 3.86E+00 6.96E-03 3.88E+00 3.84E+00 3.40E+00 PASS 3.85E+00 6.96E-03 3.87E+00 3.83E+00 3.20E+00 PASS 3.85E+00 6.96E-03 3.87E+00 3.83E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 148 3.85E+00 7.36E-03 3.87E+00 3.83E+00 2.80E+00 PASS 3.85E+00 7.58E-03 3.87E+00 3.83E+00 2.80E+00 NA TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 3 RL=600 @ +5V (V) 4.50E+00 4.00E+00 3.50E+00 3.00E+00 2.50E+00 2.00E+00 1.50E+00 1.00E+00 5.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.71. Plot of Positive Output Voltage 3 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 149 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.71. Raw data for Positive Output Voltage 3 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 3 RL=600 @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 3.84E+00 3.83E+00 3.84E+00 3.84E+00 3.86E+00 3.84E+00 3.86E+00 3.86E+00 3.85E+00 3.85E+00 3.85E+00 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 3.83E+00 3.83E+00 3.83E+00 3.83E+00 3.83E+00 3.83E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00 3.83E+00 3.83E+00 3.85E+00 3.85E+00 3.85E+00 3.83E+00 3.83E+00 3.83E+00 3.85E+00 3.85E+00 3.85E+00 3.86E+00 3.85E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00 3.85E+00 3.85E+00 3.84E+00 3.85E+00 3.85E+00 3.85E+00 2/16/2012 200 3.82E+00 3.82E+00 3.83E+00 3.83E+00 3.85E+00 3.82E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00 9.45E-03 9.14E-03 9.68E-03 9.65E-03 1.04E-02 3.87E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00 3.81E+00 3.81E+00 3.81E+00 3.81E+00 3.80E+00 3.85E+00 8.20E-03 3.87E+00 3.83E+00 3.40E+00 PASS 3.85E+00 8.03E-03 3.87E+00 3.82E+00 3.20E+00 PASS 3.85E+00 8.61E-03 3.87E+00 3.82E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 150 3.84E+00 8.60E-03 3.87E+00 3.82E+00 2.80E+00 PASS 3.84E+00 9.25E-03 3.86E+00 3.81E+00 2.80E+00 NA TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Positive Output Voltage 4 RL=600 @ +5V (V) 4.50E+00 4.00E+00 3.50E+00 3.00E+00 2.50E+00 2.00E+00 1.50E+00 1.00E+00 5.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.72. Plot of Positive Output Voltage 4 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 151 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.72. Raw data for Positive Output Voltage 4 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Positive Output Voltage 4 RL=600 @ +5V (V) Date Device 107 403 408 439 634 720 896 921 923 928 940 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 2/6/2012 0 3.85E+00 3.84E+00 3.85E+00 3.85E+00 3.86E+00 3.84E+00 3.86E+00 3.85E+00 3.85E+00 3.86E+00 3.86E+00 Total Dose (krad(Si)) 2/16/2012 2/16/2012 2/16/2012 20 50 100 3.85E+00 3.84E+00 3.84E+00 3.84E+00 3.84E+00 3.83E+00 3.85E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00 3.86E+00 3.86E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00 3.86E+00 3.86E+00 3.86E+00 3.85E+00 3.85E+00 3.84E+00 3.85E+00 3.85E+00 3.85E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00 2/16/2012 200 3.84E+00 3.83E+00 3.84E+00 3.83E+00 3.85E+00 3.83E+00 3.85E+00 3.84E+00 3.84E+00 3.85E+00 3.86E+00 3.85E+00 3.85E+00 3.84E+00 3.84E+00 3.84E+00 6.65E-03 6.65E-03 6.91E-03 6.98E-03 7.54E-03 3.87E+00 3.86E+00 3.86E+00 3.86E+00 3.86E+00 3.83E+00 3.83E+00 3.83E+00 3.82E+00 3.82E+00 3.85E+00 7.35E-03 3.87E+00 3.83E+00 3.40E+00 PASS 3.85E+00 7.50E-03 3.87E+00 3.83E+00 3.20E+00 PASS 3.85E+00 7.69E-03 3.87E+00 3.83E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 152 3.85E+00 7.83E-03 3.87E+00 3.83E+00 2.80E+00 PASS 3.84E+00 8.44E-03 3.87E+00 3.82E+00 2.80E+00 NA TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 1 RL=open @ +5V (V) 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.73. Plot of Output Voltage Low 1 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 153 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.73. Raw data for Output Voltage Low 1 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 1 RL=open @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 1.38E-02 1.38E-02 1.39E-02 1.40E-02 1.42E-02 403 1.36E-02 1.36E-02 1.37E-02 1.39E-02 1.42E-02 408 1.36E-02 1.36E-02 1.36E-02 1.37E-02 1.41E-02 439 1.36E-02 1.35E-02 1.39E-02 1.37E-02 1.41E-02 634 1.36E-02 1.36E-02 1.37E-02 1.37E-02 1.41E-02 720 1.36E-02 1.37E-02 1.36E-02 1.40E-02 1.46E-02 896 1.39E-02 1.40E-02 1.40E-02 1.41E-02 1.48E-02 921 1.37E-02 1.37E-02 1.38E-02 1.40E-02 1.46E-02 923 1.38E-02 1.37E-02 1.42E-02 1.41E-02 1.48E-02 928 1.40E-02 1.41E-02 1.41E-02 1.43E-02 1.49E-02 940 1.38E-02 1.37E-02 1.36E-02 1.38E-02 1.38E-02 Biased Statistics Average Biased 1.36E-02 1.36E-02 1.38E-02 1.38E-02 1.41E-02 Std Dev Biased 8.94E-05 1.10E-04 1.34E-04 1.41E-04 5.48E-05 Ps90%/90% (+KTL) Biased 1.39E-02 1.39E-02 1.41E-02 1.42E-02 1.43E-02 Ps90%/90% (-KTL) Biased 1.34E-02 1.33E-02 1.34E-02 1.34E-02 1.40E-02 Un-Biased Statistics Average Un-Biased 1.38E-02 1.38E-02 1.39E-02 1.41E-02 1.47E-02 Std Dev Un-Biased 1.58E-04 1.95E-04 2.41E-04 1.22E-04 1.34E-04 Ps90%/90% (+KTL) Un-Biased 1.42E-02 1.44E-02 1.46E-02 1.44E-02 1.51E-02 Ps90%/90% (-KTL) Un-Biased 1.34E-02 1.33E-02 1.33E-02 1.38E-02 1.44E-02 Specification MAX 2.50E-02 3.00E-02 4.00E-02 5.00E-02 5.00E-02 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 154 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 2 RL=open @ +5V (V) 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.74. Plot of Output Voltage Low 2 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 155 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.74. Raw data for Output Voltage Low 2 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 2 RL=open @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 1.36E-02 1.38E-02 1.38E-02 1.39E-02 1.41E-02 403 1.35E-02 1.36E-02 1.38E-02 1.38E-02 1.40E-02 408 1.35E-02 1.36E-02 1.38E-02 1.39E-02 1.41E-02 439 1.34E-02 1.35E-02 1.36E-02 1.38E-02 1.41E-02 634 1.37E-02 1.37E-02 1.36E-02 1.38E-02 1.40E-02 720 1.35E-02 1.37E-02 1.39E-02 1.40E-02 1.46E-02 896 1.41E-02 1.40E-02 1.40E-02 1.43E-02 1.48E-02 921 1.39E-02 1.40E-02 1.42E-02 1.44E-02 1.49E-02 923 1.37E-02 1.38E-02 1.40E-02 1.42E-02 1.48E-02 928 1.38E-02 1.39E-02 1.40E-02 1.42E-02 1.47E-02 940 1.38E-02 1.39E-02 1.37E-02 1.38E-02 1.38E-02 Biased Statistics Average Biased 1.35E-02 1.36E-02 1.37E-02 1.38E-02 1.41E-02 Std Dev Biased 1.14E-04 1.14E-04 1.10E-04 5.48E-05 5.48E-05 Ps90%/90% (+KTL) Biased 1.39E-02 1.40E-02 1.40E-02 1.40E-02 1.42E-02 Ps90%/90% (-KTL) Biased 1.32E-02 1.33E-02 1.34E-02 1.37E-02 1.39E-02 Un-Biased Statistics Average Un-Biased 1.38E-02 1.39E-02 1.40E-02 1.42E-02 1.48E-02 Std Dev Un-Biased 2.24E-04 1.30E-04 1.10E-04 1.48E-04 1.14E-04 Ps90%/90% (+KTL) Un-Biased 1.44E-02 1.42E-02 1.43E-02 1.46E-02 1.51E-02 Ps90%/90% (-KTL) Un-Biased 1.32E-02 1.35E-02 1.37E-02 1.38E-02 1.44E-02 Specification MAX 2.50E-02 3.00E-02 4.00E-02 5.00E-02 5.00E-02 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 156 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 3 RL=open @ +5V (V) 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.75. Plot of Output Voltage Low 3 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 157 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.75. Raw data for Output Voltage Low 3 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 3 RL=open @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 1.38E-02 1.37E-02 1.39E-02 1.39E-02 1.40E-02 403 1.36E-02 1.37E-02 1.38E-02 1.39E-02 1.41E-02 408 1.36E-02 1.36E-02 1.38E-02 1.39E-02 1.41E-02 439 1.37E-02 1.37E-02 1.38E-02 1.39E-02 1.40E-02 634 1.36E-02 1.35E-02 1.39E-02 1.39E-02 1.41E-02 720 1.37E-02 1.37E-02 1.38E-02 1.39E-02 1.46E-02 896 1.41E-02 1.41E-02 1.41E-02 1.42E-02 1.50E-02 921 1.40E-02 1.41E-02 1.42E-02 1.45E-02 1.49E-02 923 1.38E-02 1.40E-02 1.41E-02 1.43E-02 1.48E-02 928 1.39E-02 1.38E-02 1.40E-02 1.42E-02 1.49E-02 940 1.38E-02 1.39E-02 1.39E-02 1.38E-02 1.39E-02 Biased Statistics Average Biased 1.37E-02 1.36E-02 1.38E-02 1.39E-02 1.41E-02 Std Dev Biased 8.94E-05 8.94E-05 5.48E-05 0.00E+00 5.48E-05 Ps90%/90% (+KTL) Biased 1.39E-02 1.39E-02 1.40E-02 1.39E-02 1.42E-02 Ps90%/90% (-KTL) Biased 1.34E-02 1.34E-02 1.37E-02 1.39E-02 1.39E-02 Un-Biased Statistics Average Un-Biased 1.39E-02 1.39E-02 1.40E-02 1.42E-02 1.48E-02 Std Dev Un-Biased 1.58E-04 1.82E-04 1.52E-04 2.17E-04 1.52E-04 Ps90%/90% (+KTL) Un-Biased 1.43E-02 1.44E-02 1.45E-02 1.48E-02 1.53E-02 Ps90%/90% (-KTL) Un-Biased 1.35E-02 1.34E-02 1.36E-02 1.36E-02 1.44E-02 Specification MAX 2.50E-02 3.00E-02 4.00E-02 5.00E-02 5.00E-02 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 158 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 4 RL=open @ +5V (V) 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.76. Plot of Output Voltage Low 4 RL=open @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 159 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.76. Raw data for Output Voltage Low 4 RL=open @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 4 RL=open @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 1.37E-02 1.37E-02 1.38E-02 1.40E-02 1.41E-02 403 1.34E-02 1.36E-02 1.36E-02 1.37E-02 1.41E-02 408 1.36E-02 1.37E-02 1.36E-02 1.40E-02 1.41E-02 439 1.34E-02 1.35E-02 1.36E-02 1.37E-02 1.40E-02 634 1.36E-02 1.35E-02 1.37E-02 1.35E-02 1.39E-02 720 1.34E-02 1.35E-02 1.37E-02 1.40E-02 1.45E-02 896 1.38E-02 1.40E-02 1.40E-02 1.42E-02 1.47E-02 921 1.36E-02 1.37E-02 1.38E-02 1.40E-02 1.47E-02 923 1.40E-02 1.39E-02 1.40E-02 1.42E-02 1.50E-02 928 1.39E-02 1.40E-02 1.41E-02 1.42E-02 1.50E-02 940 1.38E-02 1.39E-02 1.38E-02 1.36E-02 1.37E-02 Biased Statistics Average Biased 1.35E-02 1.36E-02 1.37E-02 1.38E-02 1.40E-02 Std Dev Biased 1.34E-04 1.00E-04 8.94E-05 2.17E-04 8.94E-05 Ps90%/90% (+KTL) Biased 1.39E-02 1.39E-02 1.39E-02 1.44E-02 1.43E-02 Ps90%/90% (-KTL) Biased 1.32E-02 1.33E-02 1.34E-02 1.32E-02 1.38E-02 Un-Biased Statistics Average Un-Biased 1.37E-02 1.38E-02 1.39E-02 1.41E-02 1.48E-02 Std Dev Un-Biased 2.41E-04 2.17E-04 1.64E-04 1.10E-04 2.17E-04 Ps90%/90% (+KTL) Un-Biased 1.44E-02 1.44E-02 1.44E-02 1.44E-02 1.54E-02 Ps90%/90% (-KTL) Un-Biased 1.31E-02 1.32E-02 1.35E-02 1.38E-02 1.42E-02 Specification MAX 2.50E-02 3.00E-02 4.00E-02 5.00E-02 5.00E-02 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 160 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 1 RL=600 @ +5V (V) 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.77. Plot of Output Voltage Low 1 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 161 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.77. Raw data for Output Voltage Low 1 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 1 RL=600 @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 4.50E-03 4.30E-03 4.30E-03 4.10E-03 3.60E-03 403 4.50E-03 4.30E-03 4.20E-03 4.10E-03 3.60E-03 408 4.50E-03 4.40E-03 4.30E-03 4.20E-03 3.50E-03 439 4.50E-03 4.30E-03 4.30E-03 4.00E-03 3.40E-03 634 4.60E-03 4.40E-03 4.30E-03 4.10E-03 3.70E-03 720 4.60E-03 4.30E-03 4.30E-03 4.20E-03 3.70E-03 896 4.50E-03 4.50E-03 4.40E-03 4.20E-03 3.70E-03 921 4.70E-03 4.50E-03 4.40E-03 4.30E-03 3.80E-03 923 4.40E-03 4.40E-03 4.30E-03 4.20E-03 3.60E-03 928 4.40E-03 4.40E-03 4.30E-03 4.30E-03 3.80E-03 940 4.50E-03 4.40E-03 4.30E-03 4.40E-03 4.30E-03 Biased Statistics Average Biased 4.52E-03 4.34E-03 4.28E-03 4.10E-03 3.56E-03 Std Dev Biased 4.47E-05 5.48E-05 4.47E-05 7.07E-05 1.14E-04 Ps90%/90% (+KTL) Biased 4.64E-03 4.49E-03 4.40E-03 4.29E-03 3.87E-03 Ps90%/90% (-KTL) Biased 4.40E-03 4.19E-03 4.16E-03 3.91E-03 3.25E-03 Un-Biased Statistics Average Un-Biased 4.52E-03 4.42E-03 4.34E-03 4.24E-03 3.72E-03 Std Dev Un-Biased 1.30E-04 8.37E-05 5.48E-05 5.48E-05 8.37E-05 Ps90%/90% (+KTL) Un-Biased 4.88E-03 4.65E-03 4.49E-03 4.39E-03 3.95E-03 Ps90%/90% (-KTL) Un-Biased 4.16E-03 4.19E-03 4.19E-03 4.09E-03 3.49E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 162 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 2 RL=600 @ +5V (V) 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.78. Plot of Output Voltage Low 2 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 163 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.78. Raw data for Output Voltage Low 2 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 2 RL=600 @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 4.80E-03 4.70E-03 4.50E-03 4.50E-03 3.70E-03 403 4.60E-03 4.60E-03 4.60E-03 4.40E-03 3.80E-03 408 4.90E-03 4.90E-03 4.50E-03 4.50E-03 3.80E-03 439 4.90E-03 4.60E-03 4.50E-03 4.30E-03 3.90E-03 634 5.00E-03 4.90E-03 4.70E-03 4.50E-03 4.00E-03 720 4.80E-03 4.70E-03 4.70E-03 4.50E-03 4.00E-03 896 5.00E-03 4.80E-03 4.70E-03 4.50E-03 4.00E-03 921 5.00E-03 5.00E-03 4.60E-03 4.50E-03 4.10E-03 923 5.00E-03 4.60E-03 4.60E-03 4.40E-03 3.90E-03 928 5.10E-03 4.90E-03 4.60E-03 4.50E-03 4.00E-03 940 5.00E-03 4.60E-03 4.60E-03 4.50E-03 4.70E-03 Biased Statistics Average Biased 4.84E-03 4.74E-03 4.56E-03 4.44E-03 3.84E-03 Std Dev Biased 1.52E-04 1.52E-04 8.94E-05 8.94E-05 1.14E-04 Ps90%/90% (+KTL) Biased 5.26E-03 5.16E-03 4.81E-03 4.69E-03 4.15E-03 Ps90%/90% (-KTL) Biased 4.42E-03 4.32E-03 4.31E-03 4.19E-03 3.53E-03 Un-Biased Statistics Average Un-Biased 4.98E-03 4.80E-03 4.64E-03 4.48E-03 4.00E-03 Std Dev Un-Biased 1.10E-04 1.58E-04 5.48E-05 4.47E-05 7.07E-05 Ps90%/90% (+KTL) Un-Biased 5.28E-03 5.23E-03 4.79E-03 4.60E-03 4.19E-03 Ps90%/90% (-KTL) Un-Biased 4.68E-03 4.37E-03 4.49E-03 4.36E-03 3.81E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 164 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 3 RL=600 @ +5V (V) 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.79. Plot of Output Voltage Low 3 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 165 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.79. Raw data for Output Voltage Low 3 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 3 RL=600 @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 4.50E-03 4.40E-03 4.30E-03 4.10E-03 3.50E-03 403 4.50E-03 4.50E-03 4.30E-03 4.10E-03 3.70E-03 408 4.70E-03 4.50E-03 4.40E-03 4.20E-03 3.60E-03 439 4.60E-03 4.50E-03 4.20E-03 4.10E-03 3.70E-03 634 4.90E-03 4.70E-03 4.60E-03 4.30E-03 3.90E-03 720 4.60E-03 4.60E-03 4.60E-03 4.30E-03 4.10E-03 896 4.60E-03 4.60E-03 4.50E-03 4.30E-03 3.80E-03 921 4.60E-03 4.50E-03 4.50E-03 4.40E-03 3.90E-03 923 4.80E-03 4.70E-03 4.50E-03 4.30E-03 3.80E-03 928 4.80E-03 4.70E-03 4.50E-03 4.20E-03 3.90E-03 940 4.40E-03 4.40E-03 4.40E-03 4.30E-03 4.40E-03 Biased Statistics Average Biased 4.64E-03 4.52E-03 4.36E-03 4.16E-03 3.68E-03 Std Dev Biased 1.67E-04 1.10E-04 1.52E-04 8.94E-05 1.48E-04 Ps90%/90% (+KTL) Biased 5.10E-03 4.82E-03 4.78E-03 4.41E-03 4.09E-03 Ps90%/90% (-KTL) Biased 4.18E-03 4.22E-03 3.94E-03 3.91E-03 3.27E-03 Un-Biased Statistics Average Un-Biased 4.68E-03 4.62E-03 4.52E-03 4.30E-03 3.90E-03 Std Dev Un-Biased 1.10E-04 8.37E-05 4.47E-05 7.07E-05 1.22E-04 Ps90%/90% (+KTL) Un-Biased 4.98E-03 4.85E-03 4.64E-03 4.49E-03 4.24E-03 Ps90%/90% (-KTL) Un-Biased 4.38E-03 4.39E-03 4.40E-03 4.11E-03 3.56E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 166 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 4 RL=600 @ +5V (V) 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.80. Plot of Output Voltage Low 4 RL=600 @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 167 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.80. Raw data for Output Voltage Low 4 RL=600 @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 4 RL=600 @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 4.80E-03 4.70E-03 4.60E-03 4.40E-03 3.90E-03 403 4.90E-03 4.60E-03 4.60E-03 4.50E-03 3.90E-03 408 4.90E-03 4.90E-03 4.80E-03 4.60E-03 3.90E-03 439 4.90E-03 4.70E-03 4.60E-03 4.40E-03 3.90E-03 634 5.00E-03 4.80E-03 4.70E-03 4.50E-03 4.00E-03 720 4.90E-03 4.60E-03 4.60E-03 4.50E-03 4.10E-03 896 5.00E-03 4.80E-03 4.80E-03 4.60E-03 4.20E-03 921 5.20E-03 4.80E-03 4.80E-03 4.70E-03 4.30E-03 923 4.90E-03 4.80E-03 4.70E-03 4.50E-03 4.00E-03 928 4.90E-03 4.70E-03 4.70E-03 4.70E-03 4.20E-03 940 5.00E-03 4.70E-03 4.70E-03 4.80E-03 4.70E-03 Biased Statistics Average Biased 4.90E-03 4.74E-03 4.66E-03 4.48E-03 3.92E-03 Std Dev Biased 7.07E-05 1.14E-04 8.94E-05 8.37E-05 4.47E-05 Ps90%/90% (+KTL) Biased 5.09E-03 5.05E-03 4.91E-03 4.71E-03 4.04E-03 Ps90%/90% (-KTL) Biased 4.71E-03 4.43E-03 4.41E-03 4.25E-03 3.80E-03 Un-Biased Statistics Average Un-Biased 4.98E-03 4.74E-03 4.72E-03 4.60E-03 4.16E-03 Std Dev Un-Biased 1.30E-04 8.94E-05 8.37E-05 1.00E-04 1.14E-04 Ps90%/90% (+KTL) Un-Biased 5.34E-03 4.99E-03 4.95E-03 4.87E-03 4.47E-03 Ps90%/90% (-KTL) Un-Biased 4.62E-03 4.49E-03 4.49E-03 4.33E-03 3.85E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 168 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 1 IL=1mA @ +5V (V) 1.80E+00 1.60E+00 1.40E+00 1.20E+00 1.00E+00 8.00E-01 6.00E-01 4.00E-01 2.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.81. Plot of Output Voltage Low 1 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 169 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.81. Raw data for Output Voltage Low 1 IL=1mA @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 1 IL=1mA @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 2.44E-01 2.42E-01 2.44E-01 2.47E-01 2.63E-01 403 2.40E-01 2.39E-01 2.41E-01 2.44E-01 2.61E-01 408 2.39E-01 2.37E-01 2.40E-01 2.44E-01 2.62E-01 439 2.39E-01 2.37E-01 2.40E-01 2.43E-01 2.60E-01 634 2.37E-01 2.35E-01 2.38E-01 2.41E-01 2.59E-01 720 2.39E-01 2.36E-01 2.39E-01 2.41E-01 2.55E-01 896 2.43E-01 2.40E-01 2.42E-01 2.45E-01 2.59E-01 921 2.35E-01 2.35E-01 2.38E-01 2.40E-01 2.56E-01 923 2.43E-01 2.40E-01 2.43E-01 2.46E-01 2.61E-01 928 2.44E-01 2.40E-01 2.43E-01 2.45E-01 2.60E-01 940 2.43E-01 2.43E-01 2.43E-01 2.42E-01 2.42E-01 Biased Statistics Average Biased 2.40E-01 2.38E-01 2.41E-01 2.44E-01 2.61E-01 Std Dev Biased 2.59E-03 2.65E-03 2.19E-03 2.17E-03 1.58E-03 Ps90%/90% (+KTL) Biased 2.47E-01 2.45E-01 2.47E-01 2.50E-01 2.65E-01 Ps90%/90% (-KTL) Biased 2.33E-01 2.31E-01 2.35E-01 2.38E-01 2.57E-01 Un-Biased Statistics Average Un-Biased 2.41E-01 2.38E-01 2.41E-01 2.43E-01 2.58E-01 Std Dev Un-Biased 3.77E-03 2.49E-03 2.35E-03 2.70E-03 2.59E-03 Ps90%/90% (+KTL) Un-Biased 2.51E-01 2.45E-01 2.47E-01 2.51E-01 2.65E-01 Ps90%/90% (-KTL) Un-Biased 2.30E-01 2.31E-01 2.35E-01 2.36E-01 2.51E-01 Specification MAX 3.50E-01 8.00E-01 1.00E+00 1.60E+00 1.60E+00 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 170 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 2 IL=1mA @ +5V (V) 1.80E+00 1.60E+00 1.40E+00 1.20E+00 1.00E+00 8.00E-01 6.00E-01 4.00E-01 2.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.82. Plot of Output Voltage Low 2 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 171 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.82. Raw data for Output Voltage Low 2 IL=1mA @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 2 IL=1mA @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 2.38E-01 2.34E-01 2.37E-01 2.40E-01 2.54E-01 403 2.35E-01 2.34E-01 2.36E-01 2.38E-01 2.52E-01 408 2.33E-01 2.31E-01 2.35E-01 2.37E-01 2.51E-01 439 2.35E-01 2.33E-01 2.36E-01 2.38E-01 2.51E-01 634 2.29E-01 2.29E-01 2.31E-01 2.33E-01 2.46E-01 720 2.36E-01 2.33E-01 2.35E-01 2.37E-01 2.48E-01 896 2.39E-01 2.36E-01 2.39E-01 2.41E-01 2.53E-01 921 2.38E-01 2.36E-01 2.40E-01 2.41E-01 2.53E-01 923 2.37E-01 2.34E-01 2.38E-01 2.40E-01 2.52E-01 928 2.32E-01 2.30E-01 2.33E-01 2.37E-01 2.52E-01 940 2.39E-01 2.39E-01 2.38E-01 2.38E-01 2.38E-01 Biased Statistics Average Biased 2.34E-01 2.32E-01 2.35E-01 2.37E-01 2.51E-01 Std Dev Biased 3.32E-03 2.17E-03 2.35E-03 2.59E-03 2.95E-03 Ps90%/90% (+KTL) Biased 2.43E-01 2.38E-01 2.41E-01 2.44E-01 2.59E-01 Ps90%/90% (-KTL) Biased 2.25E-01 2.26E-01 2.29E-01 2.30E-01 2.43E-01 Un-Biased Statistics Average Un-Biased 2.36E-01 2.34E-01 2.37E-01 2.39E-01 2.52E-01 Std Dev Un-Biased 2.70E-03 2.49E-03 2.92E-03 2.05E-03 2.07E-03 Ps90%/90% (+KTL) Un-Biased 2.44E-01 2.41E-01 2.45E-01 2.45E-01 2.57E-01 Ps90%/90% (-KTL) Un-Biased 2.29E-01 2.27E-01 2.29E-01 2.34E-01 2.46E-01 Specification MAX 3.50E-01 8.00E-01 1.00E+00 1.60E+00 1.60E+00 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 172 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 3 IL=1mA @ +5V (V) 1.80E+00 1.60E+00 1.40E+00 1.20E+00 1.00E+00 8.00E-01 6.00E-01 4.00E-01 2.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.83. Plot of Output Voltage Low 3 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 173 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.83. Raw data for Output Voltage Low 3 IL=1mA @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 3 IL=1mA @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 2.43E-01 2.40E-01 2.42E-01 2.46E-01 2.64E-01 403 2.41E-01 2.38E-01 2.41E-01 2.44E-01 2.61E-01 408 2.38E-01 2.36E-01 2.39E-01 2.43E-01 2.61E-01 439 2.41E-01 2.38E-01 2.41E-01 2.44E-01 2.61E-01 634 2.34E-01 2.34E-01 2.37E-01 2.40E-01 2.57E-01 720 2.41E-01 2.37E-01 2.40E-01 2.43E-01 2.56E-01 896 2.44E-01 2.41E-01 2.44E-01 2.47E-01 2.61E-01 921 2.43E-01 2.42E-01 2.45E-01 2.47E-01 2.62E-01 923 2.41E-01 2.38E-01 2.41E-01 2.44E-01 2.60E-01 928 2.36E-01 2.34E-01 2.38E-01 2.42E-01 2.61E-01 940 2.44E-01 2.44E-01 2.44E-01 2.43E-01 2.44E-01 Biased Statistics Average Biased 2.39E-01 2.37E-01 2.40E-01 2.43E-01 2.61E-01 Std Dev Biased 3.51E-03 2.28E-03 2.00E-03 2.19E-03 2.49E-03 Ps90%/90% (+KTL) Biased 2.49E-01 2.43E-01 2.45E-01 2.49E-01 2.68E-01 Ps90%/90% (-KTL) Biased 2.30E-01 2.31E-01 2.35E-01 2.37E-01 2.54E-01 Un-Biased Statistics Average Un-Biased 2.41E-01 2.38E-01 2.42E-01 2.45E-01 2.60E-01 Std Dev Un-Biased 3.08E-03 3.21E-03 2.88E-03 2.30E-03 2.35E-03 Ps90%/90% (+KTL) Un-Biased 2.49E-01 2.47E-01 2.49E-01 2.51E-01 2.66E-01 Ps90%/90% (-KTL) Un-Biased 2.33E-01 2.30E-01 2.34E-01 2.38E-01 2.54E-01 Specification MAX 3.50E-01 8.00E-01 1.00E+00 1.60E+00 1.60E+00 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 174 TID Report 12-085 120320 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Low 4 IL=1mA @ +5V (V) 1.80E+00 1.60E+00 1.40E+00 1.20E+00 1.00E+00 8.00E-01 6.00E-01 4.00E-01 2.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.84. Plot of Output Voltage Low 4 IL=1mA @ +5V (V) versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 175 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.84. Raw data for Output Voltage Low 4 IL=1mA @ +5V (V) versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Output Voltage Low 4 IL=1mA @ +5V (V) 2/6/2012 2/16/2012 2/16/2012 2/16/2012 2/16/2012 Date Device 0 20 50 100 200 107 2.39E-01 2.37E-01 2.39E-01 2.42E-01 2.55E-01 403 2.35E-01 2.34E-01 2.35E-01 2.38E-01 2.52E-01 408 2.34E-01 2.32E-01 2.34E-01 2.37E-01 2.52E-01 439 2.34E-01 2.32E-01 2.35E-01 2.37E-01 2.51E-01 634 2.32E-01 2.30E-01 2.33E-01 2.35E-01 2.50E-01 720 2.35E-01 2.32E-01 2.34E-01 2.37E-01 2.48E-01 896 2.39E-01 2.35E-01 2.38E-01 2.40E-01 2.51E-01 921 2.30E-01 2.31E-01 2.33E-01 2.35E-01 2.48E-01 923 2.39E-01 2.36E-01 2.38E-01 2.41E-01 2.53E-01 928 2.39E-01 2.35E-01 2.38E-01 2.40E-01 2.52E-01 940 2.39E-01 2.38E-01 2.38E-01 2.38E-01 2.38E-01 Biased Statistics Average Biased 2.35E-01 2.33E-01 2.35E-01 2.38E-01 2.52E-01 Std Dev Biased 2.59E-03 2.65E-03 2.28E-03 2.59E-03 1.87E-03 Ps90%/90% (+KTL) Biased 2.42E-01 2.40E-01 2.41E-01 2.45E-01 2.57E-01 Ps90%/90% (-KTL) Biased 2.28E-01 2.26E-01 2.29E-01 2.31E-01 2.47E-01 Un-Biased Statistics Average Un-Biased 2.36E-01 2.34E-01 2.36E-01 2.39E-01 2.50E-01 Std Dev Un-Biased 3.97E-03 2.17E-03 2.49E-03 2.51E-03 2.30E-03 Ps90%/90% (+KTL) Un-Biased 2.47E-01 2.40E-01 2.43E-01 2.45E-01 2.57E-01 Ps90%/90% (-KTL) Un-Biased 2.26E-01 2.28E-01 2.29E-01 2.32E-01 2.44E-01 Specification MAX 3.50E-01 8.00E-01 1.00E+00 1.60E+00 1.60E+00 Status PASS PASS PASS PASS NA An ISO 9001:2008 and DSCC Certified Company 176 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 6.0. Summary / Conclusions The total ionizing dose testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose (TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead, during the radiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s, determined by the distance from the source. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the total ionizing dose test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. Based on this criterion the RH1014MW Quad Precision Operational Amplifier (from the lot date code identified on the first page of this test report) PASSED the total ionizing dose test to the maximum tested dose level of 200krad(Si) with all parameters remaining within their datasheet specifications. An ISO 9001:2008 and DSCC Certified Company 177 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix A: Photograph of a Sample Unit-Under-Test to Show Part Traceability An ISO 9001:2008 and DSCC Certified Company 178 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix B: Radiation Bias Connections and Absolute Maximum Ratings TID Radiation Biased Conditions: Extracted from Linear Technology RH1014 DataSheet I.D. No.6611-1014 Revision G. Pin Function Connection / Bias OUT A To Pin 2 Via 10kΩ Resistor 1 2 -IN A To Pin 1 Via 10kΩ Resistor 3 +IN A 8V Via 10kΩ Resistor 4 V+ 5 +IN B 8V Via 10kΩ Resistor 6 -IN B To Pin 7 Via 10kΩ Resistor 7 OUT B To Pin 6 Via 10kΩ Resistor 8 OUT C To Pin 9 Via 10kΩ Resistor 9 -IN C To Pin 8 Via 10kΩ Resistor 10 +IN C 8V Via 10kΩ Resistor 11 V- 12 +IN D 8V Via 10kΩ Resistor 13 -IN D To Pin 14 Via 10kΩ Resistor 14 OUT D To Pin 13 Via 10kΩ Resistor +15V Decoupled to GND W/ 0.1µF -15V Decoupled to GND W/ 0.1µF Figure B.1. Irradiation bias circuit. This figure was extracted from Linear Technology RH1014 DataSheet I.D. No.66-11-1014 Revision G. An ISO 9001:2008 and DSCC Certified Company 179 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Radiation Unbiased Conditions: Pin Function Connection / Bias OUT A GND 1 -IN A 2 GND 3 +IN A GND 4 V+ GND 5 +IN B GND 6 -IN B GND 7 OUT B GND 8 OUT C GND 9 -IN C GND 10 +IN C GND 11 V- GND 12 +IN D GND 13 -IN D GND 14 OUT D GND Figure B.2. Package drawing (for reference only). This figure was extracted from Linear Technology RH1014 DataSheet I.D. No.66-11-1014 Revision G. An ISO 9001:2008 and DSCC Certified Company 180 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Absolute Maximum Ratings: Parameter Supply Voltage Max Rating ±22V Differential Input Voltage ±30V Equal to Positive Supply Voltage Input Voltage 5V Below Negative Supply Voltage Output Short-Circuit Duration Indefinite An ISO 9001:2008 and DSCC Certified Company 181 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix C: Electrical Test Parameters and Conditions The expected ranges of values as well as the measurement conditions are taken from Linear Technology RH1014 DataSheet I.D. No.66-11-1014 Revision G. All electrical tests for this device are performed on one of Aeroflex RAD's LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that provides parameter measurements for a variety of digital, analog and mixed signal products including voltage regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System achieves accuracy and sensitivity through the use of software self-calibration and an internal relay matrix with separate family boards and custom personality adapter boards. The tester uses this relay matrix to connect the required test circuits, select the appropriate voltage / current sources and establish the needed measurement loops for all the tests performed. The measured parameters and test conditions are shown in Table C.1. A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020 for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90 KTL statistics were applied to the measured standard deviation to generate the final measurement range. This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020 mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the measurement resolution is limited by the internal DACs, which results in a measured standard deviation of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC. Note that the testing and statistics used in this document are based on an “analysis of variables” technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p. 91 for a discussion of statistical treatments). Not all measured parameters are well suited to this approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify these parameters using an “attributes” approach. An ISO 9001:2008 and DSCC Certified Company 182 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.1. Measured parameters and test conditions for the RH1014MW Quad Precision Operational Amplifier. Parameter Test Conditions Positive Supply Current (ICC+) VS=±15V Negative Supply Current (IEE-) VS=±15V Input Offset Voltage (VOS1-VOS4) VS=±15V Input Offset Current (IOS1-IOS4) VS=±15V + Input Bias Current (IB+1-IB+4) VS=±15V - Input Bias Current (IB-1-IB-4) VS=±15V Common Mode Rejection Ratio (CMRR1-CMRR4) VCM = 13.5V, –15V Power Supply Rejection Ratio (PSRR1-PSRR4) VS = ±10V to ±18V Large Signal Voltage Gain (AVOL9-AVOL12) VS=±15V, VO = ±10V, RL = 10kΩ Positive Output Voltage Swing (VOUT+1-VOUT+4) VS=±15V, RL= 10kΩ Negative Output Voltage Swing (VOUT-1-VOUT-4) VS=±15V, RL= 10kΩ Positive Slew Rate (SlewRate+1 – SlewRate+4) VS=±15V, RL= 10kΩ Negative Slew Rate (SlewRate-1 – SlewRate-4) VS=±15V, RL= 10kΩ Positive Supply Current (ICC+2) VS=+5V Negative Supply Current (IEE-2) VS=+5V Input Offset Voltage (VOS5-VOS8) VS=+5V Input Offset Current (IOS5-IOS8) VS=+5V + Input Bias Current (IB+5-IB+8) VS=+5V - Input Bias Current (IB-5-IB-8) VS=+5V Positive Output Voltage Swing (VOUT+5-VOUT+8) VS=+5V, No Load Positive Output Voltage Swing (VOUT+9-VOUT+12) VS=+5V, RL= 600Ω Output Voltage Low (VOUT-5-VOUT-8) VS=+5V, No Load Output Voltage Low (VOUT-9-VOUT-12) VS=+5V, RL= 600Ω Output Voltage Low (VOUT-13-VOUT-16) VS=+5V, ISINK= 1mA An ISO 9001:2008 and DSCC Certified Company 183 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH1014MW Quad Precision Operational Amplifier. Parameter Pre-Irradiation Specification MIN Positive Supply Current (ICC+) MAX Measurement Precision/Resolution 2.20E-03 A ±5.26E-06 A Negative Supply Current (IEE-) -2.20E-03 A ±5.55E-06 A Input Offset Voltage (VOS1-VOS4) -3.00E-04 V 3.00E-04 V ±3.40E-06 V Input Offset Current (IOS1-IOS4) -1.00E-08 A +1.00E-08 A ±3.04E-11 A + Input Bias Current (IB+1-IB+4) -3.00E-08 A 3.00E-08 A ±6.02E-11 A - Input Bias Current (IB-1-IB-4) -3.00E-08 A 3.00E-08 A ±6.48E-11 A Common Mode Rejection Ratio (CMRR1-CMRR4) 97 dB ±4.79E-01 dB Power Supply Rejection Ratio (PSRR1-PSRR4) 100 dB ±3.23E+00 dB 1.20E+03 V/mV ±1.72E+04 V/mV 12.5 V ±1.90E-03 V Large Signal Voltage Gain (AVOL9-AVOL12) Positive Output Voltage Swing (VOUT+1-VOUT+4) Negative Output Voltage Swing (VOUT-1-VOUT-4) -12.5 V Positive Slew Rate (SlewRate+1-SlewRate+4) 0.2 V/µs Negative Slew Rate (SlewRate-1-SlewRate-4) Positive Supply Current (ICC+2) ±8.71E-04 V ±1.26E-02 V/µs -0.2 V/µs ±2.34E-02 V/µs 2.00E-03 A ±3.87E-06 A Negative Supply Current (IEE-2) -2.00E-03 A ±5.08E-06 A Input Offset Voltage (VOS5-VOS8) -4.50E-04 V 4.50E-04 V ±1.00E-06 V Input Offset Current (IOS5-IOS8) -1.00E-08 A 1.00E-08 A ±3.61E-11 A + Input Bias Current (IB+5-IB+8) -5.00E-08 A 5.00E-08 A ±8.80E-11 A - Input Bias Current (IB-5-IB-8) -5.00E-08 A 5.00E-08 A ±7.13E-11 A Positive Output Voltage Swing (VOUT+5-VOUT+8) 4.0 V ±1.17E-03 V Positive Output Voltage Swing (VOUT+9-VOUT+12) 3.4 V ±1.38E-03 V Output Voltage Low (VOUT-5-VOUT-8) 2.50E-02 V ±1.70E-04 V Output Voltage Low (VOUT-9-VOUT-12) 1.00E-02 V ±2.27E-04 V Output Voltage Low (VOUT-13-VOUT-16) 0.35 V ±1.09E-03 V An ISO 9001:2008 and DSCC Certified Company 184 TID Report 12-085 120320 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix D: List of Figures Used in the Results Section (Section 5) 5.1. 5.2. 5.3. 5.4. 5.5. 5.6. 5.7. 5.8. 5.9. 5.10. 5.11. 5.12. 5.13. 5.14. 5.15. 5.16. 5.17. 5.18. 5.19. 5.20. 5.21. 5.22. 5.23. 5.24. 5.25. 5.26. 5.27. 5.28. 5.29. 5.30. 5.31. 5.32. 5.33. 5.34. 5.35. 5.36. 5.37. 5.38. 5.39. 5.40. Positive Supply Current @ +/-15V (A) Negative Supply Current @ +/-15V (A) Offset Voltage 1 @ +/-15V (V) Offset Voltage 2 @ +/-15V (V) Offset Voltage 3 @ +/-15V (V) Offset Voltage 4 @ +/-15V (V) Offset Current 1 @ +/-15V (A) Offset Current 2 @ +/-15V (A) Offset Current 3 @ +/-15V (A) Offset Current 4 @ +/-15V (A) Positive Bias Current 1 @ +/-15V (A) Positive Bias Current 2 @ +/-15V (A) Positive Bias Current 3 @ +/-15V (A) Positive Bias Current 4 @ +/-15V (A) Negative Bias Current 1 @ +/-15V (A) Negative Bias Current 2 @ +/-15V (A) Negative Bias Current 3 @ +/-15V (A) Negative Bias Current 4 @ +/-15V (A) Common Mode Rejection Ratio 1 (dB) Common Mode Rejection Ratio 2 (dB) Common Mode Rejection Ratio 3 (dB) Common Mode Rejection Ratio 4 (dB) Power Supply Rejection Ratio 1 (dB) Power Supply Rejection Ratio 2 (dB) Power Supply Rejection Ratio 3 (dB) Power Supply Rejection Ratio 4 (dB) Open Loop Gain 1 RL=10k VO=+/-10V (V/mV) Open Loop Gain 2 RL=10k VO=+/-10V (V/mV) Open Loop Gain 3 RL=10k VO=+/-10V (V/mV) Open Loop Gain 4 RL=10k VO=+/-10V (V/mV) Positive Output Voltage 1 @ +/-15V (V) Positive Output Voltage 2 @ +/-15V (V) Positive Output Voltage 3 @ +/-15V (V) Positive Output Voltage 4 @ +/-15V (V) Negative Output Voltage 1 @ +/-15V (V) Negative Output Voltage 2 @ +/-15V (V) Negative Output Voltage 3 @ +/-15V (V) Negative Output Voltage 4 @ +/-15V (V) Positive Slew Rate 1 @ +/-15V (V/us) Positive Slew Rate 2 @ +/-15V (V/us) An ISO 9001:2008 and DSCC Certified Company 185 TID Report 12-085 120320 R1.1 5.41. 5.42. 5.43. 5.44. 5.45. 5.46. 5.47. 5.48. 5.49. 5.50. 5.51. 5.52. 5.53. 5.54. 5.55. 5.56. 5.57. 5.58. 5.59. 5.60. 5.61. 5.62. 5.63. 5.64. 5.65. 5.66. 5.67. 5.68. 5.69. 5.70. 5.71. 5.72. 5.73. 5.74. 5.75. 5.76. 5.77. 5.78. 5.79. 5.80. 5.81. 5.82. Positive Slew Rate 3 @ +/-15V (V/us) Positive Slew Rate 4 @ +/-15V (V/us) Negative Slew Rate 1 @ +/-15V (V/us) Negative Slew Rate 2 @ +/-15V (V/us) Negative Slew Rate 3 @ +/-15V (V/us) Negative Slew Rate 4 @ +/-15V (V/us) Positive Supply Current @ +5V (A) Negative Supply Current @ +5V (A) Offset Voltage 1 @ +5V (V) Offset Voltage 2 @ +5V (V) Offset Voltage 3 @ +5V (V) Offset Voltage 4 @ +5V (V) Offset Current 1 @ +5V (A) Offset Current 2 @ +5V (A) Offset Current 3 @ +5V (A) Offset Current 4 @ +5V (A) Positive Bias Current 1 @ +5V (A) Positive Bias Current 2 @ +5V (A) Positive Bias Current 3 @ +5V (A) Positive Bias Current 4 @ +5V (A) Negative Bias Current 1 @ +5V (A) Negative Bias Current 2 @ +5V (A) Negative Bias Current 3 @ +5V (A) Negative Bias Current 4 @ +5V (A) Positive Output Voltage 1 RL=open @ +5V (V) Positive Output Voltage 2 RL=open @ +5V (V) Positive Output Voltage 3 RL=open @ +5V (V) Positive Output Voltage 4 RL=open @ +5V (V) Positive Output Voltage 1 RL=600 @ +5V (V) Positive Output Voltage 2 RL=600 @ +5V (V) Positive Output Voltage 3 RL=600 @ +5V (V) Positive Output Voltage 4 RL=600 @ +5V (V) Output Voltage Low 1 RL=open @ +5V (V) Output Voltage Low 2 RL=open @ +5V (V) Output Voltage Low 3 RL=open @ +5V (V) Output Voltage Low 4 RL=open @ +5V (V) Output Voltage Low 1 RL=600 @ +5V (V) Output Voltage Low 2 RL=600 @ +5V (V) Output Voltage Low 3 RL=600 @ +5V (V) Output Voltage Low 4 RL=600 @ +5V (V) Output Voltage Low 1 IL=1mA @ +5V (V) Output Voltage Low 2 IL=1mA @ +5V (V) An ISO 9001:2008 and DSCC Certified Company 186 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Report 12-085 120320 R1.1 5.83. 5.84. Output Voltage Low 3 IL=1mA @ +5V (V) Output Voltage Low 4 IL=1mA @ +5V (V) An ISO 9001:2008 and DSCC Certified Company 187 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800