ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Products contained in this shipment may be subject to ITAR regulations. Warning: The export of these commodity(ies), technology, or software are subject either to the U.S. Commerce Department Export Administration Regulations (E.A.R.), or to the U.S. State Department International Traffic In Arms Regulations (I.T.A.R.). Diversion, the shipment to unauthorized locations or entities, or the disclosure of related technical data or software to unauthorized foreign nationals is contrary to U.S. law and is prohibited. If export is authorized to a specific country or end-users, compliance with the U.S. export laws is required prior to transfer, transshipment on a non-continuous voyage, or disposal in any other country, or to any other end-user of these commodities, either in their original form or after being incorporated into other end-items. An ISO 9001:2008 and DSCC Certified Company 1 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Enhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp for Linear Technology Customer: Linear Technology, PO# 5259J RAD Job Number: 12-640 Part Type Tested: RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp. Traceability Information: Fab Lot Number: W1046927.1, Wafer Number: 1, Assembly Lot Number:656718.1, Date Code: 1203A. See photograph of unit under test in Appendix A. Quantity of Units: 22 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 2 units for control. Serial numbers 557, 563, 564, 567 and 569 were biased during irradiation, serial numbers 570, 571, 572, 573 and 574 were unbiased during irradiation and serial numbers 584 and 585 were used as control. See Appendix B for the radiation bias connection table. Radiation and Electrical Test Increments: 10mrad(Si)/s ionizing radiation with electrical test increments: pre-irradiation, 10krad(Si), 20krad(Si), 30krad(Si) and 50krad(Si). Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD Overtest and Post-Irradiation Anneal: No overtest. 24-hour room temperature anneal followed by a 168-hour 100°C anneal. Both anneals were performed in the same electrical bias condition as the irradiations. Electrical measurements were made following each anneal increment. Radiation Test Standard: MIL-STD-750E TM1019 and/or MIL-STD-883H TM1019 Condition D. Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS04, Calibration Date: 4/26/2012, Calibration Due: 4/26/2013. LTS2101 Family Board, Entity ID FB10. LTS0600 Test Fixture, Entity ID TF03. RH1499 BGSS 061114 DUT Board. Test Program: RH1499X.SRC Facility and Radiation Source: Aeroflex RAD's Longmire Laboratories, Colorado Springs, CO. Gamma rays provided by Co60 (GB-150) low dose rate source. Dosimetry performed by Air Ionization Chamber (AIC) traceable to NIST. Aeroflex RAD's dosimetry has been audited by DSCC and Aeroflex RAD has been awarded Laboratory Suitability for MIL-STD-750 and MIL-STD-883 TM 1019. Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and MIL-STD-750. Low Dose Rate Test Result: PASSED the enhanced low dose rate sensitivity test to the maximum tested dose level of 50krad(Si) with all parameters remaining within their datasheet specifications. An ISO 9001:2008 and DSCC Certified Company 2 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 1.0. Overview and Background It is well known that total dose ionizing radiation can cause parametric degradation and ultimately functional failure in electronic devices. The damage occurs via electron-hole pair production, transport and trapping in the dielectric regions. In advanced CMOS technology nodes (0.6µm and smaller) the bulk of the damage is manifested in the thicker isolation regions, such as shallow trench or local oxidation of silicon (LOCOS) oxides (also known as "birds-beak" oxides). However, many linear and mixed signal devices that utilize bipolar minority carrier elements exhibit an enhanced low dose rate sensitivity (ELDRS). At this time there is no known or accepted a priori method for predicting susceptibility to ELDRS or simulating the low dose rate sensitivity with a "conventional" room temperature 50-300rad(Si)/s irradiation (Condition A in MIL-STD-883 TM 1019.8). Over the past 10 years a number of accelerating techniques have been examined, including an elevated temperature anneal, such as that used for MOS devices (see ASTM-F-1892 for more technical details) and irradiating at various temperatures. However, none of these techniques have proven useful across the wide variety of linear and/or mixed signal devices used in spaceborne applications. The latest requirement incorporated in MIL-STD-883 TM 1019 requires that devices that could potentially exhibit ELDRS "shall be tested either at the intended application dose rate, at a prescribed low dose rate to an overtest radiation level, or with an accelerated test such as an elevated temperature irradiation test that includes a parameter delta design margin". While the recently released MIL-STD883 TM 1019 allows for accelerated testing, the requirements for this are to essentially perform a low dose rate ELDRS test to verify the suitability of the acceleration method on the component of interest before the acceleration technique can be instituted. Based on the limitations of accelerated testing and to meet the requirements of MIL-STD-883 TM1019.8 Condition D, we have performed a low dose rate test at 10mrad(Si)/s. 2.0. Radiation Test Apparatus The low dose rate testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The low dose rate source is a GB-150 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead. During the irradiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from approximately 1mrad(Si)/s to a maximum of approximately 50rad(Si)/s, determined by the distance from the source. For low dose rate testing described in this report, the devices are placed approximately 2-meters from the Co-60 rods. The irradiator calibration is maintained by Aeroflex RAD's Longmire Laboratories using air ionization chamber (AIC) dosimetry traceable to the National Institute of Standards and Technology (NIST). Figure 2.1 shows a photograph of the GB-150 Co-60 irradiator at Aeroflex RAD's Longmire Laboratory facility. An ISO 9001:2008 and DSCC Certified Company 3 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Figure 2.1. Aeroflex RAD's Co-60 irradiator. The dose rate is obtained by positioning the device-under-test at a fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately 50rad(Si)/s close to the rods down to <1mrad(Si)/s at a distance of approximately 4-meters. An ISO 9001:2008 and DSCC Certified Company 4 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 3.0. Radiation Test Conditions The RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp described in this final report were irradiated using a split 15V supply and with all pins tied to ground, that is biased and unbiased. See Appendix B for details on the biasing conditions during radiation exposure. In our opinion, this bias circuit satisfies the requirements of MIL-STD-883H TM1019.8 Section 3.9.3 Bias and Loading Conditions which states "The bias applied to the test devices shall be selected to produce the greatest radiation induced damage or the worst-case damage for the intended application, if known. While maximum voltage is often worst case some bipolar linear device parameters (e.g. input bias current or maximum output load current) exhibit more degradation with 0 V bias." The devices were irradiated to a maximum total ionizing dose level of 50krad(Si) with incremental readings at 10krad(Si), 20krad(Si) and 30krad(Si). Electrical testing occurred within one hour following the end of each irradiation segment. For intermediate irradiations, the units were tested and returned to total dose exposure within two hours from the end of the previous radiation increment. The radiation exposure bias board was positioned in the Co-60 cell to provide the targeted dose rate of10mrad(Si)/s and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019.8 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1) initially, (2) when the source is changed, or (3) when the orientation or configuration of the source, container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g., a TLD) in the device-irradiation container at the approximate test-device position. If it can be demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors due to dose enhancement, the Pb/Al container may be omitted". The final dose rate within the lead-aluminum box was determined based on air ionization chamber (AIC) dosimetry measurements just prior to the beginning of the total dose irradiations. The final dose rate for this work was 10mrad(Si)/s with a precision of ±5%. An ISO 9001:2008 and DSCC Certified Company 5 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 4.0. Tested Parameters During the enhanced low dose rate sensitivity testing the following electrical parameters were measured pre- and post-irradiation: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. +Supply Current 15V (A) @ VS=+/-15V -Supply Current 15V (A) @ VS=+/-15V Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V An ISO 9001:2008 and DSCC Certified Company 6 ELDRS Report 12-640 130125 R1.1 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. 70. 71. 72. 73. 74. 75. 76. 77. 78. 79. 80. 81. 82. 83. 84. 85. 86. 87. Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V An ISO 9001:2008 and DSCC Certified Company 7 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ELDRS Report 12-640 130125 R1.1 88. CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V 89. Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V 90. Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V 91. Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V 92. Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V 93. PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V 94. PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V 95. +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V 96. +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V 97. +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V 98. +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V 99. -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V 100. -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V 101. -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V 102. -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V 103. +Supply Current 5V (A) @ VS=+5V 104. -Supply Current 5V (A) @ VS=+5V 105. Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V 106. Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V 107. Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V 108. Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V 109. Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V 110. Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V 111. Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V 112. Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V 113. +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V 114. +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V 115. +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V 116. +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V 117. -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V 118. -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V 119. -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V 120. -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V 121. Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V 122. Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V 123. Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V 124. Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V 125. Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V 126. Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V 127. Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V 128. Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V 129. +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V 130. +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V 131. +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V 132. +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V 133. -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V An ISO 9001:2008 and DSCC Certified Company 8 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ELDRS Report 12-640 130125 R1.1 134. -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V 135. -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V 136. -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V 137. Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA 138. Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA 139. Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA 140. Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA 141. Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA 142. Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA 143. Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA 144. Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA 145. Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA 146. Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA 147. Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA 148. Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA 149. Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA 150. Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA 151. Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA 152. Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA 153. Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA 154. Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA 155. Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA 156. Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA 157. Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA 158. Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA 159. Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA 160. Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA 161. Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ 162. Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ 163. Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ 164. Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ 165. Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V 166. Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V 167. Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V 168. Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V 169. CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V 170. CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V 171. Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V 172. Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V 173. Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V 174. Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V 175. PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V 176. PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V 177. +Short-Circuit Current2 1 5V (A) @ VS=+5V 178. +Short-Circuit Current2 2 5V (A) @ VS=+5V 179. +Short-Circuit Current2 3 5V (A) @ VS=+5V An ISO 9001:2008 and DSCC Certified Company 9 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 180. +Short-Circuit Current2 4 5V (A) @ VS=+5V 181. -Short-Circuit Current2 1 5V (A) @ VS=+5V 182. -Short-Circuit Current2 2 5V (A) @ VS=+5V 183. -Short-Circuit Current2 3 5V (A) @ VS=+5V 184. -Short-Circuit Current2 4 5V (A) @ VS=+5V 185. Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz 186. Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz 187. Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz 188. Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz 189. +Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ 190. +Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ 191. +Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ 192. +Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ 193. -Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ 194. -Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ 195. -Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ 196. -Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ Appendix C details the measured parameters, test conditions, pre-irradiation specification and measurement resolution for each of the measurements. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the low dose rate test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. Further, MIL-STD-883H, TM 1019.8 Section 3.13.1.1 Characterization test to determine if a part exhibits ELDRS' states the following: Select a minimum random sample of 21 devices from a population representative of recent production runs. Smaller sample sizes may be used if agreed upon between the parties to the test. All of the selected devices shall have undergone appropriate elevated temperature reliability screens, e.g. burn-in and high temperature storage life. Divide the samples into four groups of 5 each and use the remaining part for a control. Perform pre-irradiation electrical characterization on all parts assuring that they meet the Group A electrical tests. Irradiate 5 samples under a 0 volt bias and another 5 under the irradiation bias given in the acquisition specification at 50300 rad(Si)/s and room temperature. Irradiate 5 samples under a 0 volt bias and another 5 under irradiation bias given in the acquisition specification at < 10mrad(Si)/s and room temperature. Irradiate all samples to the same dose levels, including 0.5 and 1.0 times the anticipated specification dose, and An ISO 9001:2008 and DSCC Certified Company 10 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 repeat the electrical characterization on each part at each dose level. Post irradiation electrical measurements shall be performed per paragraph 3.10 where the low dose rate test is considered Condition D. Calculate the radiation induced change in each electrical parameter (∆para) for each sample at each radiation level. Calculate the ratio of the median ∆para at low dose rate to the median ∆para at high dose rate for each irradiation bias group at each total dose level. If this ratio exceeds 1.5 for any of the most sensitive parameters then the part is considered to be ELDRS susceptible. This test does not apply to parameters which exhibit changes that are within experimental error or whose values are below the pre-irradiation electrical specification limits at low dose rate at the specification dose. Therefore, the data in this report can be analyzed along with the high dose rate report titled "Total Ionizing Dose (TID) Radiation Testing of the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp for Linear Technology" to demonstrate that these parts do not exhibit ELDRS as defined in the current test method. An ISO 9001:2008 and DSCC Certified Company 11 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 5.0. ELDRS Test Results Based on this criterion the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp (from the lot traceability information provided on the first page of this test report) PASSED the enhanced low dose rate sensitivity test to the maximum tested dose level of 50krad(Si) with all parameters remaining within their datasheet specifications. Figures 5.1 through 5.196 show plots of all the measured parameters versus total ionizing dose while Tables 5.1 - 5.196 show the corresponding raw data for each of these parameters. In the data plots the solid diamonds are the average of the measured data points for the sample irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the units irradiated with all pins tied to ground. The black lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. In addition to the radiation test results, the data plots and tables described above contain anneal data. The anneals are performed to better understand the underlying physical mechanisms responsible for radiation-induced parametric shifts and are not part of the criteria used to establish whether or not the lot passes or fails the low dose rate test. In all cases the parts either improved or exhibited no change during the anneal. The control units, as expected, show no significant changes to any of the parameters. Therefore we can conclude that the electrical testing remained in control throughout the duration of the tests and the observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section to facilitate the location of a particular parameter. An ISO 9001:2008 and DSCC Certified Company 12 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased +Supply Current 15V (A) @ VS=+/-15V 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.1. Plot of +Supply Current 15V (A) @ VS=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 13 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.1. Raw data for +Supply Current 15V (A) @ VS=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Supply Current 15V (A) @ VS=+/-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 0 7.80E-03 7.75E-03 7.75E-03 7.69E-03 7.72E-03 7.71E-03 7.64E-03 7.79E-03 7.56E-03 7.73E-03 7.71E-03 7.77E-03 10 7.75E-03 7.72E-03 7.73E-03 7.68E-03 7.69E-03 7.68E-03 7.58E-03 7.75E-03 7.55E-03 7.69E-03 7.72E-03 7.74E-03 Total Dose (krad(Si)) 20 30 7.75E-03 7.74E-03 7.69E-03 7.70E-03 7.71E-03 7.74E-03 7.65E-03 7.65E-03 7.66E-03 7.66E-03 7.67E-03 7.65E-03 7.57E-03 7.57E-03 7.74E-03 7.72E-03 7.52E-03 7.50E-03 7.69E-03 7.68E-03 7.72E-03 7.72E-03 7.82E-03 7.76E-03 50 7.69E-03 7.64E-03 7.65E-03 7.59E-03 7.60E-03 7.58E-03 7.54E-03 7.67E-03 7.44E-03 7.61E-03 7.68E-03 7.76E-03 24 Hr Anneal 60 7.68E-03 7.63E-03 7.64E-03 7.57E-03 7.60E-03 7.58E-03 7.49E-03 7.66E-03 7.43E-03 7.61E-03 7.65E-03 7.70E-03 168 Hr Anneal 70 7.70E-03 7.67E-03 7.68E-03 7.61E-03 7.62E-03 7.61E-03 7.52E-03 7.68E-03 7.46E-03 7.63E-03 7.67E-03 7.73E-03 Biased Statistics Average Biased 7.74E-03 7.71E-03 7.69E-03 7.70E-03 7.63E-03 7.62E-03 7.66E-03 Std Dev Biased 3.98E-05 3.01E-05 3.86E-05 4.31E-05 4.23E-05 4.18E-05 3.82E-05 Ps90%/90% (+KTL) Biased 7.85E-03 7.79E-03 7.80E-03 7.81E-03 7.75E-03 7.74E-03 7.76E-03 Ps90%/90% (-KTL) Biased 7.63E-03 7.63E-03 7.58E-03 7.58E-03 7.52E-03 7.51E-03 7.55E-03 Un-Biased Statistics Average Un-Biased 7.69E-03 7.65E-03 7.64E-03 7.63E-03 7.57E-03 7.56E-03 7.58E-03 Std Dev Un-Biased 9.16E-05 8.18E-05 9.19E-05 8.73E-05 8.75E-05 8.99E-05 9.02E-05 Ps90%/90% (+KTL) Un-Biased 7.94E-03 7.87E-03 7.89E-03 7.86E-03 7.81E-03 7.80E-03 7.83E-03 Ps90%/90% (-KTL) Un-Biased 7.43E-03 7.43E-03 7.39E-03 7.39E-03 7.33E-03 7.31E-03 7.33E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 14 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased -Supply Current 15V (A) @ VS=+/-15V 0.00E+00 -2.00E-03 -4.00E-03 -6.00E-03 -8.00E-03 -1.00E-02 -1.20E-02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.2. Plot of -Supply Current 15V (A) @ VS=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 15 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.2. Raw data for -Supply Current 15V (A) @ VS=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Supply Current 15V (A) @ VS=+/-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 0 -7.82E-03 -7.77E-03 -7.77E-03 -7.71E-03 -7.74E-03 -7.73E-03 -7.66E-03 -7.82E-03 -7.58E-03 -7.75E-03 -7.73E-03 -7.79E-03 Biased Statistics Average Biased -7.76E-03 Std Dev Biased 3.98E-05 Ps90%/90% (+KTL) Biased -7.65E-03 Ps90%/90% (-KTL) Biased -7.87E-03 Un-Biased Statistics Average Un-Biased -7.71E-03 Std Dev Un-Biased 9.12E-05 Ps90%/90% (+KTL) Un-Biased -7.46E-03 Ps90%/90% (-KTL) Un-Biased -7.96E-03 Specification MIN -1.00E-02 Status PASS 10 -7.78E-03 -7.74E-03 -7.75E-03 -7.70E-03 -7.71E-03 -7.70E-03 -7.61E-03 -7.77E-03 -7.57E-03 -7.71E-03 -7.75E-03 -7.76E-03 Total Dose (krad(Si)) 20 30 -7.77E-03 -7.77E-03 -7.71E-03 -7.72E-03 -7.73E-03 -7.76E-03 -7.67E-03 -7.67E-03 -7.68E-03 -7.68E-03 -7.69E-03 -7.67E-03 -7.59E-03 -7.60E-03 -7.76E-03 -7.75E-03 -7.54E-03 -7.53E-03 -7.72E-03 -7.70E-03 -7.74E-03 -7.74E-03 -7.84E-03 -7.78E-03 50 -7.71E-03 -7.66E-03 -7.67E-03 -7.61E-03 -7.62E-03 -7.60E-03 -7.56E-03 -7.69E-03 -7.46E-03 -7.64E-03 -7.70E-03 -7.79E-03 24 Hr Anneal 60 -7.71E-03 -7.65E-03 -7.66E-03 -7.59E-03 -7.62E-03 -7.60E-03 -7.51E-03 -7.68E-03 -7.45E-03 -7.63E-03 -7.67E-03 -7.72E-03 168 Hr Anneal 70 -7.72E-03 -7.70E-03 -7.70E-03 -7.63E-03 -7.65E-03 -7.63E-03 -7.54E-03 -7.70E-03 -7.48E-03 -7.65E-03 -7.69E-03 -7.75E-03 -7.73E-03 -7.71E-03 -7.72E-03 -7.66E-03 -7.65E-03 -7.68E-03 2.95E-05 3.85E-05 4.40E-05 4.16E-05 4.35E-05 3.73E-05 -7.65E-03 -7.61E-03 -7.60E-03 -7.54E-03 -7.53E-03 -7.58E-03 -7.81E-03 -7.82E-03 -7.84E-03 -7.77E-03 -7.76E-03 -7.78E-03 -7.67E-03 8.18E-05 -7.45E-03 -7.90E-03 -1.00E-02 PASS -7.66E-03 9.32E-05 -7.40E-03 -7.92E-03 -1.00E-02 PASS -7.65E-03 8.66E-05 -7.41E-03 -7.89E-03 -1.00E-02 PASS -7.59E-03 8.80E-05 -7.35E-03 -7.83E-03 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 16 -7.58E-03 9.20E-05 -7.32E-03 -7.83E-03 -1.00E-02 PASS -7.60E-03 9.10E-05 -7.35E-03 -7.85E-03 -1.00E-02 PASS Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.3. Plot of Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 17 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.3. Raw data for Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.48E-04 -2.10E-04 -4.82E-05 5.74E-05 -1.84E-04 5.61E-05 -3.67E-04 1.40E-04 -4.45E-05 -8.40E-06 -4.66E-04 1.51E-04 Total Dose (krad(Si)) 20 30 -1.60E-04 -1.61E-04 -2.21E-04 -2.22E-04 -5.59E-05 -5.40E-05 4.52E-05 4.38E-05 -1.90E-04 -1.89E-04 4.24E-05 3.99E-05 -3.76E-04 -3.78E-04 1.25E-04 1.22E-04 -5.16E-05 -5.65E-05 -1.75E-05 -2.13E-05 -4.67E-04 -4.67E-04 1.53E-04 1.47E-04 10 -1.57E-04 -2.18E-04 -5.46E-05 4.73E-05 -1.91E-04 4.28E-05 -3.75E-04 1.26E-04 -4.97E-05 -1.89E-05 -4.67E-04 1.46E-04 50 -1.69E-04 -2.24E-04 -6.20E-05 4.32E-05 -1.93E-04 2.84E-05 -3.80E-04 1.22E-04 -6.55E-05 -2.74E-05 -4.70E-04 1.50E-04 24 Hr Anneal 60 -1.68E-04 -2.26E-04 -6.43E-05 4.44E-05 -1.95E-04 2.82E-05 -3.82E-04 1.17E-04 -6.15E-05 -2.96E-05 -4.70E-04 1.43E-04 168 Hr Anneal 70 -1.65E-04 -2.43E-04 -6.27E-05 3.74E-05 -1.94E-04 3.19E-05 -3.91E-04 1.16E-04 -7.41E-05 -2.98E-05 -4.69E-04 1.46E-04 -1.07E-04 -1.15E-04 -1.16E-04 -1.17E-04 -1.21E-04 -1.22E-04 -1.25E-04 1.10E-04 1.10E-04 1.09E-04 1.10E-04 1.10E-04 1.11E-04 1.12E-04 1.96E-04 1.86E-04 1.84E-04 1.84E-04 1.81E-04 1.82E-04 1.83E-04 -4.10E-04 -4.16E-04 -4.16E-04 -4.17E-04 -4.23E-04 -4.26E-04 -4.33E-04 -4.49E-05 1.93E-04 4.86E-04 -5.75E-04 -8.00E-04 PASS 8.00E-04 PASS -5.50E-05 1.91E-04 4.69E-04 -5.79E-04 -9.50E-04 PASS 9.50E-04 PASS -5.54E-05 1.91E-04 4.69E-04 -5.80E-04 -9.50E-04 PASS 9.50E-04 PASS -5.90E-05 1.91E-04 4.65E-04 -5.82E-04 -9.50E-04 PASS 9.50E-04 PASS -6.43E-05 1.90E-04 4.56E-04 -5.85E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 18 -6.56E-05 1.90E-04 4.54E-04 -5.85E-04 -9.50E-04 PASS 9.50E-04 PASS -6.95E-05 1.94E-04 4.61E-04 -6.00E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.4. Plot of Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 19 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.4. Raw data for Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.52E-04 -2.29E-04 -5.87E-05 -1.74E-04 8.87E-06 -1.31E-04 3.05E-05 -2.01E-05 -2.13E-04 -1.07E-04 -2.87E-04 4.11E-05 Total Dose (krad(Si)) 20 30 -1.62E-04 -1.60E-04 -2.35E-04 -2.37E-04 -6.16E-05 -6.21E-05 -1.79E-04 -1.79E-04 6.21E-06 6.81E-06 -1.39E-04 -1.41E-04 2.64E-05 2.66E-05 -3.87E-05 -3.99E-05 -2.17E-04 -2.20E-04 -1.13E-04 -1.14E-04 -2.89E-04 -2.88E-04 4.24E-05 3.93E-05 10 -1.61E-04 -2.37E-04 -6.36E-05 -1.76E-04 8.62E-06 -1.39E-04 2.60E-05 -3.63E-05 -2.18E-04 -1.11E-04 -2.88E-04 4.01E-05 50 -1.65E-04 -2.37E-04 -6.82E-05 -1.84E-04 6.22E-06 -1.44E-04 2.43E-05 -4.51E-05 -2.17E-04 -1.17E-04 -2.89E-04 4.26E-05 24 Hr Anneal 60 -1.63E-04 -2.37E-04 -7.04E-05 -1.85E-04 7.30E-06 -1.42E-04 2.37E-05 -4.67E-05 -2.19E-04 -1.19E-04 -2.88E-04 3.63E-05 168 Hr Anneal 70 -1.69E-04 -2.32E-04 -6.07E-05 -1.68E-04 3.55E-06 -1.42E-04 1.10E-05 -4.68E-05 -2.26E-04 -1.19E-04 -2.89E-04 3.88E-05 -1.21E-04 -1.26E-04 -1.26E-04 -1.26E-04 -1.30E-04 -1.30E-04 -1.25E-04 9.49E-05 9.76E-05 9.70E-05 9.74E-05 9.76E-05 9.75E-05 9.48E-05 1.39E-04 1.42E-04 1.40E-04 1.41E-04 1.38E-04 1.38E-04 1.35E-04 -3.81E-04 -3.94E-04 -3.92E-04 -3.93E-04 -3.97E-04 -3.97E-04 -3.85E-04 -8.82E-05 9.56E-05 1.74E-04 -3.50E-04 -8.00E-04 PASS 8.00E-04 PASS -9.56E-05 9.41E-05 1.62E-04 -3.54E-04 -9.50E-04 PASS 9.50E-04 PASS -9.62E-05 9.36E-05 1.61E-04 -3.53E-04 -9.50E-04 PASS 9.50E-04 PASS -9.75E-05 9.45E-05 1.62E-04 -3.57E-04 -9.50E-04 PASS 9.50E-04 PASS -9.99E-05 9.28E-05 1.55E-04 -3.54E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 20 -1.01E-04 9.28E-05 1.54E-04 -3.55E-04 -9.50E-04 PASS 9.50E-04 PASS -1.04E-04 9.08E-05 1.44E-04 -3.53E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.5. Plot of Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 21 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.5. Raw data for Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.57E-04 -4.40E-05 -5.19E-05 2.44E-05 -1.89E-04 -1.03E-04 -2.18E-04 1.66E-04 6.59E-05 3.01E-05 3.35E-04 -1.15E-06 Total Dose (krad(Si)) 20 30 2.41E-04 2.37E-04 -5.26E-05 -5.34E-05 -6.08E-05 -5.84E-05 1.56E-05 1.76E-05 -1.98E-04 -2.01E-04 -1.12E-04 -1.14E-04 -2.30E-04 -2.31E-04 1.50E-04 1.46E-04 5.81E-05 5.80E-05 2.25E-05 1.74E-05 3.37E-04 3.37E-04 -1.88E-06 -4.06E-06 10 2.44E-04 -5.22E-05 -5.80E-05 1.88E-05 -1.94E-04 -1.10E-04 -2.27E-04 1.54E-04 5.99E-05 2.34E-05 3.38E-04 -4.05E-06 50 2.31E-04 -5.36E-05 -6.83E-05 1.50E-05 -2.06E-04 -1.18E-04 -2.38E-04 1.43E-04 5.27E-05 1.36E-05 3.34E-04 -1.39E-06 24 Hr Anneal 60 2.31E-04 -5.42E-05 -7.15E-05 1.36E-05 -2.06E-04 -1.19E-04 -2.39E-04 1.40E-04 5.13E-05 1.26E-05 3.31E-04 -7.67E-06 168 Hr Anneal 70 2.25E-04 -4.91E-05 -7.32E-05 7.42E-06 -1.99E-04 -1.14E-04 -2.25E-04 1.27E-04 4.73E-05 7.54E-06 3.32E-04 -5.86E-06 -5.78E-07 -8.21E-06 -1.10E-05 -1.15E-05 -1.65E-05 -1.74E-05 -1.78E-05 1.64E-04 1.61E-04 1.61E-04 1.60E-04 1.60E-04 1.60E-04 1.55E-04 4.48E-04 4.33E-04 4.30E-04 4.27E-04 4.22E-04 4.21E-04 4.07E-04 -4.49E-04 -4.49E-04 -4.52E-04 -4.50E-04 -4.55E-04 -4.56E-04 -4.43E-04 -1.18E-05 1.50E-04 4.00E-04 -4.23E-04 -8.00E-04 PASS 8.00E-04 PASS -2.00E-05 1.49E-04 3.90E-04 -4.30E-04 -9.50E-04 PASS 9.50E-04 PASS -2.23E-05 1.49E-04 3.87E-04 -4.32E-04 -9.50E-04 PASS 9.50E-04 PASS -2.47E-05 1.49E-04 3.83E-04 -4.32E-04 -9.50E-04 PASS 9.50E-04 PASS -2.93E-05 1.50E-04 3.81E-04 -4.40E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 22 -3.08E-05 1.49E-04 3.78E-04 -4.39E-04 -9.50E-04 PASS 9.50E-04 PASS -3.15E-05 1.39E-04 3.50E-04 -4.13E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.6. Plot of Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 23 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.6. Raw data for Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.03E-04 -7.33E-05 1.41E-04 1.30E-04 -3.39E-04 3.99E-05 1.21E-04 -6.99E-05 7.85E-05 -2.56E-04 3.18E-05 -2.69E-04 Total Dose (krad(Si)) 20 30 -1.14E-04 -1.17E-04 -8.45E-05 -8.34E-05 1.35E-04 1.39E-04 1.23E-04 1.27E-04 -3.43E-04 -3.46E-04 3.27E-05 3.72E-05 1.11E-04 1.12E-04 -8.08E-05 -8.27E-05 7.32E-05 7.61E-05 -2.60E-04 -2.61E-04 3.07E-05 3.08E-05 -2.69E-04 -2.70E-04 10 -1.13E-04 -8.28E-05 1.36E-04 1.26E-04 -3.44E-04 3.23E-05 1.11E-04 -8.05E-05 7.15E-05 -2.63E-04 3.22E-05 -2.72E-04 50 -1.23E-04 -8.94E-05 1.32E-04 1.22E-04 -3.45E-04 4.01E-05 1.09E-04 -8.56E-05 7.35E-05 -2.62E-04 2.75E-05 -2.68E-04 24 Hr Anneal 60 -1.22E-04 -9.18E-05 1.27E-04 1.20E-04 -3.44E-04 4.00E-05 1.06E-04 -8.63E-05 7.27E-05 -2.62E-04 2.40E-05 -2.72E-04 168 Hr Anneal 70 -1.19E-04 -8.14E-05 1.29E-04 1.17E-04 -3.41E-04 3.18E-05 1.05E-04 -8.33E-05 6.10E-05 -2.72E-04 2.44E-05 -2.72E-04 -4.88E-05 -5.57E-05 -5.67E-05 -5.60E-05 -6.07E-05 -6.22E-05 -5.92E-05 1.98E-04 1.98E-04 1.97E-04 2.00E-04 1.98E-04 1.95E-04 1.93E-04 4.93E-04 4.87E-04 4.83E-04 4.92E-04 4.81E-04 4.73E-04 4.71E-04 -5.90E-04 -5.99E-04 -5.97E-04 -6.04E-04 -6.02E-04 -5.98E-04 -5.90E-04 -1.72E-05 1.51E-04 3.97E-04 -4.32E-04 -8.00E-04 PASS 8.00E-04 PASS -2.58E-05 1.51E-04 3.87E-04 -4.39E-04 -9.50E-04 PASS 9.50E-04 PASS -2.47E-05 1.50E-04 3.86E-04 -4.35E-04 -9.50E-04 PASS 9.50E-04 PASS -2.38E-05 1.52E-04 3.92E-04 -4.40E-04 -9.50E-04 PASS 9.50E-04 PASS -2.49E-05 1.51E-04 3.90E-04 -4.40E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 24 -2.59E-05 1.50E-04 3.87E-04 -4.39E-04 -9.50E-04 PASS 9.50E-04 PASS -3.15E-05 1.52E-04 3.84E-04 -4.47E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.7. Plot of Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 25 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.7. Raw data for Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.69E-09 -4.40E-09 -7.80E-10 5.32E-09 1.41E-09 -6.10E-10 -5.92E-09 1.79E-09 -2.68E-09 4.79E-09 -7.55E-09 1.59E-09 10 2.54E-09 -4.95E-09 -1.07E-09 5.02E-09 9.00E-11 -8.90E-10 -6.11E-09 1.71E-09 -2.81E-09 4.55E-09 -8.16E-09 1.60E-10 Total Dose 20 1.88E-09 -5.17E-09 -1.63E-09 4.57E-09 -3.40E-10 -4.20E-10 -6.82E-09 1.79E-09 -3.10E-09 4.74E-09 -8.42E-09 -3.00E-11 (krad(Si)) 30 1.36E-09 -5.57E-09 -2.18E-09 4.84E-09 -1.20E-09 -4.20E-10 -6.93E-09 1.94E-09 -2.94E-09 4.51E-09 -8.69E-09 8.00E-11 50 5.00E-10 -7.02E-09 -3.88E-09 4.15E-09 -2.19E-09 -4.80E-10 -6.93E-09 1.45E-09 -3.34E-09 5.55E-09 -8.84E-09 -5.00E-11 24 Hr Anneal 60 -6.30E-10 -7.50E-09 -4.75E-09 3.53E-09 -2.94E-09 -7.10E-10 -8.02E-09 7.90E-10 -4.25E-09 3.99E-09 -9.11E-09 -9.00E-11 168 Hr Anneal 70 1.02E-09 -6.07E-09 -3.29E-09 3.38E-09 -1.40E-09 -6.50E-10 -6.86E-09 1.06E-09 -3.29E-09 4.61E-09 -9.20E-09 -2.70E-10 8.48E-10 3.26E-10 -1.38E-10 -5.50E-10 -1.69E-09 -2.46E-09 -1.27E-09 3.67E-09 3.77E-09 3.67E-09 3.90E-09 4.25E-09 4.19E-09 3.67E-09 1.09E-08 1.07E-08 9.92E-09 1.02E-08 9.97E-09 9.02E-09 8.80E-09 -9.22E-09 -1.00E-08 -1.02E-08 -1.13E-08 -1.34E-08 -1.39E-08 -1.13E-08 -5.26E-10 4.10E-09 1.07E-08 -1.18E-08 -7.00E-08 PASS 7.00E-08 PASS -7.10E-10 4.10E-09 1.05E-08 -1.19E-08 -1.00E-07 PASS 1.00E-07 PASS -7.62E-10 4.45E-09 1.14E-08 -1.30E-08 -1.00E-07 PASS 1.00E-07 PASS -7.68E-10 4.42E-09 1.13E-08 -1.29E-08 -1.00E-07 PASS 1.00E-07 PASS -7.50E-10 4.73E-09 1.22E-08 -1.37E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 26 -1.64E-09 4.64E-09 1.11E-08 -1.44E-08 -1.00E-07 PASS 1.00E-07 PASS -1.03E-09 4.34E-09 1.09E-08 -1.29E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.8. Plot of Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 27 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.8. Raw data for Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.87E-09 -2.46E-09 -2.76E-09 9.00E-11 2.82E-09 -2.56E-09 -1.09E-09 1.24E-09 2.10E-10 -2.40E-09 2.85E-09 1.97E-09 10 2.62E-09 -3.31E-09 -3.70E-09 -4.70E-10 3.14E-09 -2.69E-09 -1.62E-09 1.00E-09 -1.50E-10 -2.53E-09 2.38E-09 4.30E-10 Total Dose 20 2.22E-09 -3.44E-09 -4.53E-09 -6.80E-10 3.16E-09 -3.18E-09 -1.60E-09 1.21E-09 -5.10E-10 -3.06E-09 1.90E-09 2.30E-10 (krad(Si)) 30 1.87E-09 -3.78E-09 -4.77E-09 -1.01E-09 2.76E-09 -3.34E-09 -9.50E-10 1.20E-09 -7.20E-10 -3.00E-09 1.66E-09 2.10E-10 50 5.10E-10 -4.33E-09 -5.57E-09 -1.85E-09 2.58E-09 -3.43E-09 -2.19E-09 1.49E-09 -6.10E-10 -2.36E-09 1.56E-09 2.50E-10 24 Hr Anneal 60 6.00E-11 -5.24E-09 -6.37E-09 -2.43E-09 2.07E-09 -3.94E-09 -3.25E-09 5.50E-10 -1.05E-09 -3.49E-09 1.31E-09 2.60E-10 168 Hr Anneal 70 9.30E-10 -4.13E-09 -4.98E-09 -2.08E-09 1.60E-09 -3.55E-09 -2.67E-09 1.21E-09 -3.70E-10 -2.94E-09 1.23E-09 1.90E-10 1.12E-10 -3.44E-10 -6.54E-10 -9.86E-10 -1.73E-09 -2.38E-09 -1.73E-09 2.73E-09 3.20E-09 3.38E-09 3.33E-09 3.36E-09 3.53E-09 2.94E-09 7.60E-09 8.43E-09 8.60E-09 8.14E-09 7.48E-09 7.30E-09 6.33E-09 -7.37E-09 -9.12E-09 -9.91E-09 -1.01E-08 -1.09E-08 -1.21E-08 -9.80E-09 -9.20E-10 1.65E-09 3.60E-09 -5.44E-09 -7.00E-08 PASS 7.00E-08 PASS -1.20E-09 1.59E-09 3.16E-09 -5.56E-09 -1.00E-07 PASS 1.00E-07 PASS -1.43E-09 1.84E-09 3.62E-09 -6.48E-09 -1.00E-07 PASS 1.00E-07 PASS -1.36E-09 1.85E-09 3.72E-09 -6.44E-09 -1.00E-07 PASS 1.00E-07 PASS -1.42E-09 1.91E-09 3.83E-09 -6.67E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 28 -2.24E-09 1.92E-09 3.02E-09 -7.49E-09 -1.00E-07 PASS 1.00E-07 PASS -1.66E-09 2.01E-09 3.84E-09 -7.17E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.9. Plot of Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 29 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.9. Raw data for Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 3.99E-09 5.18E-09 3.84E-09 1.11E-08 7.50E-10 7.99E-09 1.44E-09 4.53E-09 8.00E-09 1.40E-10 5.40E-09 -8.40E-10 10 1.73E-09 3.48E-09 1.74E-09 9.38E-09 -1.41E-09 6.57E-09 -9.00E-11 3.10E-09 6.44E-09 -1.24E-09 3.91E-09 -3.49E-09 Total Dose 20 6.80E-10 2.21E-09 1.50E-10 7.63E-09 -2.75E-09 5.67E-09 -1.02E-09 2.21E-09 5.80E-09 -2.31E-09 2.67E-09 -4.29E-09 (krad(Si)) 30 -5.60E-10 9.80E-10 -9.00E-10 6.86E-09 -4.21E-09 4.89E-09 -1.25E-09 1.24E-09 5.18E-09 -3.08E-09 1.90E-09 -4.93E-09 50 -1.73E-09 -3.80E-10 -2.13E-09 5.63E-09 -5.90E-09 4.04E-09 -2.65E-09 9.60E-10 4.28E-09 -3.44E-09 1.25E-09 -5.64E-09 24 Hr Anneal 60 -2.38E-09 -1.36E-09 -2.30E-09 5.47E-09 -6.48E-09 3.42E-09 -3.17E-09 -1.70E-10 3.73E-09 -3.79E-09 1.17E-09 -5.78E-09 168 Hr Anneal 70 -1.29E-09 -7.80E-10 -2.24E-09 6.12E-09 -4.59E-09 3.76E-09 -1.86E-09 9.50E-10 4.56E-09 -2.95E-09 1.17E-09 -5.54E-09 4.97E-09 2.98E-09 1.58E-09 4.34E-10 -9.02E-10 -1.41E-09 -5.56E-10 3.80E-09 3.99E-09 3.83E-09 4.06E-09 4.19E-09 4.32E-09 4.01E-09 1.54E-08 1.39E-08 1.21E-08 1.16E-08 1.06E-08 1.04E-08 1.04E-08 -5.45E-09 -7.95E-09 -8.91E-09 -1.07E-08 -1.24E-08 -1.33E-08 -1.15E-08 4.42E-09 3.63E-09 1.44E-08 -5.54E-09 -7.00E-08 PASS 7.00E-08 PASS 2.96E-09 3.61E-09 1.29E-08 -6.94E-09 -1.00E-07 PASS 1.00E-07 PASS 2.07E-09 3.73E-09 1.23E-08 -8.16E-09 -1.00E-07 PASS 1.00E-07 PASS 1.40E-09 3.66E-09 1.14E-08 -8.64E-09 -1.00E-07 PASS 1.00E-07 PASS 6.38E-10 3.62E-09 1.06E-08 -9.28E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 30 4.00E-12 3.54E-09 9.70E-09 -9.70E-09 -1.00E-07 PASS 1.00E-07 PASS 8.92E-10 3.32E-09 9.99E-09 -8.20E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.10. Plot of Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 31 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.10. Raw data for Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 1.06E-09 -2.10E-09 1.26E-08 6.14E-09 -3.46E-09 2.78E-09 6.18E-09 -2.00E-10 8.59E-09 1.74E-09 1.79E-09 -2.72E-09 10 -2.35E-09 -5.72E-09 9.17E-09 2.54E-09 -5.70E-09 -1.00E-10 3.24E-09 -3.05E-09 5.79E-09 -8.60E-10 -5.70E-10 -6.40E-09 Total Dose 20 -3.80E-09 -7.54E-09 6.30E-09 1.60E-10 -7.01E-09 -1.45E-09 2.39E-09 -4.01E-09 5.18E-09 -2.14E-09 -1.83E-09 -7.22E-09 (krad(Si)) 30 -4.69E-09 -8.30E-09 5.26E-09 -5.30E-10 -8.29E-09 -1.51E-09 1.65E-09 -4.97E-09 4.88E-09 -2.04E-09 -2.41E-09 -7.57E-09 50 -5.64E-09 -9.31E-09 4.32E-09 -2.08E-09 -8.40E-09 -1.60E-09 1.52E-09 -4.48E-09 4.25E-09 -3.07E-09 -2.88E-09 -8.13E-09 24 Hr Anneal 60 -6.27E-09 -1.06E-08 3.50E-09 -2.02E-09 -8.90E-09 -2.60E-09 8.00E-10 -5.48E-09 3.22E-09 -3.62E-09 -2.93E-09 -8.27E-09 168 Hr Anneal 70 -5.35E-09 -9.33E-09 4.83E-09 -1.27E-09 -9.31E-09 -1.66E-09 1.46E-09 -5.14E-09 4.51E-09 -3.16E-09 -3.13E-09 -8.36E-09 2.84E-09 -4.12E-10 -2.38E-09 -3.31E-09 -4.22E-09 -4.87E-09 -4.09E-09 6.57E-09 6.33E-09 5.74E-09 5.76E-09 5.54E-09 5.69E-09 6.00E-09 2.08E-08 1.70E-08 1.34E-08 1.25E-08 1.10E-08 1.07E-08 1.24E-08 -1.52E-08 -1.78E-08 -1.81E-08 -1.91E-08 -1.94E-08 -2.05E-08 -2.05E-08 3.82E-09 3.53E-09 1.35E-08 -5.87E-09 -7.00E-08 PASS 7.00E-08 PASS 1.00E-09 3.50E-09 1.06E-08 -8.60E-09 -1.00E-07 PASS 1.00E-07 PASS -6.00E-12 3.72E-09 1.02E-08 -1.02E-08 -1.00E-07 PASS 1.00E-07 PASS -3.98E-10 3.77E-09 9.94E-09 -1.07E-08 -1.00E-07 PASS 1.00E-07 PASS -6.76E-10 3.54E-09 9.03E-09 -1.04E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 32 -1.54E-09 3.50E-09 8.07E-09 -1.11E-08 -1.00E-07 PASS 1.00E-07 PASS -7.98E-10 3.82E-09 9.68E-09 -1.13E-08 -1.00E-07 PASS 1.00E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 Total Dose (krad(Si)) 50 24 60Hr Anneal 16870 Hr Anneal Figure 5.11. Plot of +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 33 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.11. Raw data for +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.89E-07 -3.13E-07 -3.21E-07 -3.31E-07 -3.17E-07 -3.23E-07 -3.10E-07 -3.04E-07 -3.12E-07 -3.09E-07 -2.88E-07 -2.97E-07 10 -2.97E-07 -3.25E-07 -3.33E-07 -3.46E-07 -3.31E-07 -3.27E-07 -3.15E-07 -3.09E-07 -3.14E-07 -3.13E-07 -2.87E-07 -3.00E-07 Total Dose (krad(Si)) 20 30 -3.03E-07 -3.09E-07 -3.33E-07 -3.37E-07 -3.46E-07 -3.47E-07 -3.56E-07 -3.58E-07 -3.40E-07 -3.48E-07 -3.33E-07 -3.40E-07 -3.22E-07 -3.28E-07 -3.15E-07 -3.23E-07 -3.22E-07 -3.28E-07 -3.18E-07 -3.25E-07 -2.88E-07 -2.88E-07 -2.95E-07 -2.99E-07 50 -3.23E-07 -3.55E-07 -3.62E-07 -3.70E-07 -3.63E-07 -3.60E-07 -3.46E-07 -3.39E-07 -3.48E-07 -3.40E-07 -2.91E-07 -2.98E-07 24 Hr Anneal 60 -3.23E-07 -3.56E-07 -3.64E-07 -3.73E-07 -3.61E-07 -3.58E-07 -3.47E-07 -3.38E-07 -3.48E-07 -3.40E-07 -2.93E-07 -3.03E-07 168 Hr Anneal 70 -3.10E-07 -3.35E-07 -3.48E-07 -3.54E-07 -3.45E-07 -3.40E-07 -3.30E-07 -3.25E-07 -3.30E-07 -3.27E-07 -2.92E-07 -3.01E-07 -3.14E-07 -3.26E-07 -3.36E-07 -3.40E-07 -3.55E-07 -3.56E-07 -3.38E-07 1.57E-08 1.83E-08 2.00E-08 1.90E-08 1.85E-08 1.91E-08 1.73E-08 -2.71E-07 -2.76E-07 -2.81E-07 -2.88E-07 -3.04E-07 -3.03E-07 -2.91E-07 -3.57E-07 -3.76E-07 -3.90E-07 -3.92E-07 -4.06E-07 -4.08E-07 -3.86E-07 -3.12E-07 6.86E-09 -2.93E-07 -3.30E-07 -7.15E-07 PASS 7.15E-07 PASS -3.15E-07 6.87E-09 -2.97E-07 -3.34E-07 -7.65E-07 PASS 7.65E-07 PASS -3.22E-07 6.70E-09 -3.04E-07 -3.40E-07 -8.15E-07 PASS 8.15E-07 PASS -3.29E-07 6.58E-09 -3.11E-07 -3.47E-07 -8.15E-07 PASS 8.15E-07 PASS -3.47E-07 8.20E-09 -3.24E-07 -3.69E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 34 -3.46E-07 7.86E-09 -3.25E-07 -3.68E-07 -8.65E-07 PASS 8.65E-07 PASS -3.30E-07 5.77E-09 -3.15E-07 -3.46E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.12. Plot of +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 35 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.12. Raw data for +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.77E-07 -3.33E-07 -3.17E-07 -3.18E-07 -2.98E-07 -3.16E-07 -3.07E-07 -2.97E-07 -3.01E-07 -3.00E-07 -3.11E-07 -3.10E-07 10 -2.86E-07 -3.49E-07 -3.30E-07 -3.30E-07 -3.11E-07 -3.20E-07 -3.13E-07 -3.02E-07 -3.03E-07 -3.04E-07 -3.10E-07 -3.14E-07 Total Dose (krad(Si)) 20 30 -2.93E-07 -2.99E-07 -3.55E-07 -3.60E-07 -3.38E-07 -3.41E-07 -3.38E-07 -3.45E-07 -3.19E-07 -3.24E-07 -3.27E-07 -3.33E-07 -3.20E-07 -3.25E-07 -3.08E-07 -3.16E-07 -3.10E-07 -3.17E-07 -3.10E-07 -3.17E-07 -3.11E-07 -3.11E-07 -3.09E-07 -3.13E-07 50 -3.14E-07 -3.74E-07 -3.60E-07 -3.59E-07 -3.38E-07 -3.54E-07 -3.40E-07 -3.31E-07 -3.31E-07 -3.35E-07 -3.15E-07 -3.12E-07 24 Hr Anneal 60 -3.14E-07 -3.74E-07 -3.60E-07 -3.60E-07 -3.37E-07 -3.52E-07 -3.45E-07 -3.32E-07 -3.30E-07 -3.34E-07 -3.17E-07 -3.16E-07 168 Hr Anneal 70 -3.00E-07 -3.58E-07 -3.39E-07 -3.40E-07 -3.21E-07 -3.35E-07 -3.28E-07 -3.17E-07 -3.19E-07 -3.20E-07 -3.16E-07 -3.15E-07 -3.09E-07 -3.21E-07 -3.29E-07 -3.34E-07 -3.49E-07 -3.49E-07 -3.32E-07 2.15E-08 2.37E-08 2.37E-08 2.35E-08 2.33E-08 2.35E-08 2.18E-08 -2.50E-07 -2.56E-07 -2.64E-07 -2.69E-07 -2.85E-07 -2.85E-07 -2.72E-07 -3.68E-07 -3.86E-07 -3.94E-07 -3.98E-07 -4.13E-07 -4.14E-07 -3.91E-07 -3.04E-07 7.39E-09 -2.84E-07 -3.25E-07 -7.15E-07 PASS 7.15E-07 PASS -3.08E-07 7.87E-09 -2.87E-07 -3.30E-07 -7.65E-07 PASS 7.65E-07 PASS -3.15E-07 8.01E-09 -2.93E-07 -3.37E-07 -8.15E-07 PASS 8.15E-07 PASS -3.22E-07 7.60E-09 -3.01E-07 -3.42E-07 -8.15E-07 PASS 8.15E-07 PASS -3.38E-07 9.47E-09 -3.12E-07 -3.64E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 36 -3.39E-07 9.50E-09 -3.13E-07 -3.65E-07 -8.65E-07 PASS 8.65E-07 PASS -3.24E-07 7.47E-09 -3.03E-07 -3.44E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.13. Plot of +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 37 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.13. Raw data for +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.77E-07 -3.26E-07 -3.18E-07 -3.13E-07 -2.98E-07 -3.13E-07 -3.06E-07 -2.96E-07 -2.94E-07 -3.00E-07 -3.10E-07 -3.19E-07 10 -2.85E-07 -3.37E-07 -3.30E-07 -3.24E-07 -3.10E-07 -3.16E-07 -3.10E-07 -3.00E-07 -2.95E-07 -3.03E-07 -3.08E-07 -3.21E-07 Total Dose (krad(Si)) 20 30 -2.92E-07 -2.98E-07 -3.47E-07 -3.53E-07 -3.39E-07 -3.45E-07 -3.33E-07 -3.37E-07 -3.18E-07 -3.23E-07 -3.22E-07 -3.30E-07 -3.17E-07 -3.22E-07 -3.06E-07 -3.13E-07 -3.02E-07 -3.09E-07 -3.09E-07 -3.16E-07 -3.10E-07 -3.10E-07 -3.16E-07 -3.21E-07 50 -3.12E-07 -3.66E-07 -3.61E-07 -3.54E-07 -3.37E-07 -3.50E-07 -3.36E-07 -3.28E-07 -3.24E-07 -3.32E-07 -3.13E-07 -3.20E-07 24 Hr Anneal 60 -3.12E-07 -3.68E-07 -3.60E-07 -3.56E-07 -3.37E-07 -3.48E-07 -3.37E-07 -3.28E-07 -3.23E-07 -3.31E-07 -3.15E-07 -3.24E-07 168 Hr Anneal 70 -2.99E-07 -3.50E-07 -3.44E-07 -3.35E-07 -3.21E-07 -3.32E-07 -3.24E-07 -3.15E-07 -3.11E-07 -3.18E-07 -3.14E-07 -3.23E-07 -3.06E-07 -3.17E-07 -3.26E-07 -3.31E-07 -3.46E-07 -3.47E-07 -3.30E-07 1.94E-08 2.06E-08 2.16E-08 2.18E-08 2.18E-08 2.24E-08 2.04E-08 -2.53E-07 -2.61E-07 -2.66E-07 -2.72E-07 -2.86E-07 -2.85E-07 -2.74E-07 -3.60E-07 -3.74E-07 -3.85E-07 -3.91E-07 -4.06E-07 -4.08E-07 -3.86E-07 -3.02E-07 7.63E-09 -2.81E-07 -3.22E-07 -7.15E-07 PASS 7.15E-07 PASS -3.05E-07 8.33E-09 -2.82E-07 -3.27E-07 -7.65E-07 PASS 7.65E-07 PASS -3.11E-07 8.26E-09 -2.88E-07 -3.34E-07 -8.15E-07 PASS 8.15E-07 PASS -3.18E-07 8.09E-09 -2.96E-07 -3.40E-07 -8.15E-07 PASS 8.15E-07 PASS -3.34E-07 9.94E-09 -3.07E-07 -3.61E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 38 -3.34E-07 9.68E-09 -3.07E-07 -3.60E-07 -8.65E-07 PASS 8.65E-07 PASS -3.20E-07 7.98E-09 -2.98E-07 -3.42E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.14. Plot of +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 39 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.14. Raw data for +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.91E-07 -3.12E-07 -3.12E-07 -3.29E-07 -3.19E-07 -3.18E-07 -3.05E-07 -3.10E-07 -3.15E-07 -3.10E-07 -2.81E-07 -2.97E-07 10 -2.99E-07 -3.24E-07 -3.25E-07 -3.40E-07 -3.32E-07 -3.22E-07 -3.10E-07 -3.14E-07 -3.16E-07 -3.13E-07 -2.80E-07 -3.00E-07 Total Dose (krad(Si)) 20 30 -3.07E-07 -3.13E-07 -3.32E-07 -3.36E-07 -3.34E-07 -3.36E-07 -3.53E-07 -3.57E-07 -3.45E-07 -3.49E-07 -3.28E-07 -3.34E-07 -3.17E-07 -3.23E-07 -3.21E-07 -3.28E-07 -3.24E-07 -3.30E-07 -3.19E-07 -3.26E-07 -2.80E-07 -2.81E-07 -2.95E-07 -2.99E-07 50 -3.28E-07 -3.53E-07 -3.54E-07 -3.69E-07 -3.63E-07 -3.52E-07 -3.38E-07 -3.50E-07 -3.49E-07 -3.46E-07 -2.83E-07 -2.98E-07 24 Hr Anneal 60 -3.28E-07 -3.55E-07 -3.54E-07 -3.71E-07 -3.62E-07 -3.52E-07 -3.40E-07 -3.50E-07 -3.49E-07 -3.46E-07 -2.85E-07 -3.02E-07 168 Hr Anneal 70 -3.13E-07 -3.34E-07 -3.34E-07 -3.54E-07 -3.48E-07 -3.35E-07 -3.25E-07 -3.31E-07 -3.32E-07 -3.28E-07 -2.84E-07 -3.01E-07 -3.12E-07 -3.24E-07 -3.34E-07 -3.38E-07 -3.53E-07 -3.54E-07 -3.37E-07 1.40E-08 1.53E-08 1.77E-08 1.70E-08 1.58E-08 1.61E-08 1.58E-08 -2.74E-07 -2.82E-07 -2.86E-07 -2.92E-07 -3.10E-07 -3.10E-07 -2.93E-07 -3.51E-07 -3.66E-07 -3.83E-07 -3.85E-07 -3.97E-07 -3.98E-07 -3.80E-07 -3.12E-07 4.87E-09 -2.98E-07 -3.25E-07 -7.15E-07 PASS 7.15E-07 PASS -3.15E-07 4.30E-09 -3.03E-07 -3.27E-07 -7.65E-07 PASS 7.65E-07 PASS -3.22E-07 4.11E-09 -3.10E-07 -3.33E-07 -8.15E-07 PASS 8.15E-07 PASS -3.28E-07 4.03E-09 -3.17E-07 -3.39E-07 -8.15E-07 PASS 8.15E-07 PASS -3.47E-07 5.31E-09 -3.32E-07 -3.62E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 40 -3.47E-07 5.06E-09 -3.34E-07 -3.61E-07 -8.65E-07 PASS 8.65E-07 PASS -3.30E-07 3.61E-09 -3.20E-07 -3.40E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.15. Plot of -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 41 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.15. Raw data for -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.91E-07 -3.08E-07 -3.20E-07 -3.36E-07 -3.18E-07 -3.22E-07 -3.03E-07 -3.06E-07 -3.09E-07 -3.13E-07 -2.80E-07 -2.98E-07 10 -2.99E-07 -3.20E-07 -3.32E-07 -3.51E-07 -3.31E-07 -3.25E-07 -3.08E-07 -3.10E-07 -3.11E-07 -3.17E-07 -2.78E-07 -3.00E-07 Total Dose (krad(Si)) 20 30 -3.05E-07 -3.10E-07 -3.27E-07 -3.31E-07 -3.39E-07 -3.41E-07 -3.60E-07 -3.62E-07 -3.39E-07 -3.45E-07 -3.32E-07 -3.39E-07 -3.15E-07 -3.20E-07 -3.17E-07 -3.24E-07 -3.18E-07 -3.25E-07 -3.22E-07 -3.29E-07 -2.79E-07 -2.79E-07 -2.95E-07 -2.99E-07 50 -3.23E-07 -3.47E-07 -3.58E-07 -3.75E-07 -3.60E-07 -3.57E-07 -3.35E-07 -3.40E-07 -3.40E-07 -3.49E-07 -2.82E-07 -2.98E-07 24 Hr Anneal 60 -3.22E-07 -3.47E-07 -3.58E-07 -3.76E-07 -3.57E-07 -3.56E-07 -3.35E-07 -3.38E-07 -3.39E-07 -3.48E-07 -2.83E-07 -3.02E-07 168 Hr Anneal 70 -3.10E-07 -3.28E-07 -3.39E-07 -3.59E-07 -3.39E-07 -3.39E-07 -3.23E-07 -3.26E-07 -3.27E-07 -3.31E-07 -2.82E-07 -3.00E-07 -3.14E-07 -3.26E-07 -3.34E-07 -3.38E-07 -3.53E-07 -3.52E-07 -3.35E-07 1.65E-08 1.91E-08 2.02E-08 1.92E-08 1.93E-08 1.97E-08 1.77E-08 -2.69E-07 -2.74E-07 -2.78E-07 -2.85E-07 -3.00E-07 -2.98E-07 -2.86E-07 -3.60E-07 -3.79E-07 -3.89E-07 -3.90E-07 -4.06E-07 -4.06E-07 -3.84E-07 -3.11E-07 7.27E-09 -2.91E-07 -3.31E-07 -7.15E-07 PASS 7.15E-07 PASS -3.14E-07 7.06E-09 -2.95E-07 -3.34E-07 -7.65E-07 PASS 7.65E-07 PASS -3.21E-07 6.84E-09 -3.02E-07 -3.40E-07 -8.15E-07 PASS 8.15E-07 PASS -3.27E-07 7.15E-09 -3.08E-07 -3.47E-07 -8.15E-07 PASS 8.15E-07 PASS -3.44E-07 8.88E-09 -3.20E-07 -3.68E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 42 -3.43E-07 8.70E-09 -3.19E-07 -3.67E-07 -8.65E-07 PASS 8.65E-07 PASS -3.29E-07 6.29E-09 -3.12E-07 -3.46E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.16. Plot of -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 43 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.16. Raw data for -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.80E-07 -3.30E-07 -3.14E-07 -3.17E-07 -3.00E-07 -3.13E-07 -3.06E-07 -2.98E-07 -3.01E-07 -2.97E-07 -3.14E-07 -3.12E-07 10 -2.88E-07 -3.41E-07 -3.26E-07 -3.29E-07 -3.14E-07 -3.17E-07 -3.11E-07 -3.02E-07 -3.03E-07 -3.01E-07 -3.12E-07 -3.14E-07 Total Dose (krad(Si)) 20 30 -2.95E-07 -3.01E-07 -3.52E-07 -3.55E-07 -3.33E-07 -3.35E-07 -3.37E-07 -3.41E-07 -3.22E-07 -3.26E-07 -3.23E-07 -3.30E-07 -3.18E-07 -3.24E-07 -3.09E-07 -3.16E-07 -3.09E-07 -3.15E-07 -3.07E-07 -3.14E-07 -3.13E-07 -3.13E-07 -3.09E-07 -3.13E-07 50 -3.14E-07 -3.68E-07 -3.53E-07 -3.55E-07 -3.40E-07 -3.49E-07 -3.37E-07 -3.33E-07 -3.30E-07 -3.31E-07 -3.16E-07 -3.12E-07 24 Hr Anneal 60 -3.14E-07 -3.68E-07 -3.53E-07 -3.58E-07 -3.39E-07 -3.49E-07 -3.38E-07 -3.32E-07 -3.29E-07 -3.30E-07 -3.17E-07 -3.16E-07 168 Hr Anneal 70 -3.01E-07 -3.53E-07 -3.34E-07 -3.37E-07 -3.22E-07 -3.31E-07 -3.25E-07 -3.18E-07 -3.18E-07 -3.16E-07 -3.16E-07 -3.14E-07 -3.08E-07 -3.20E-07 -3.28E-07 -3.32E-07 -3.46E-07 -3.46E-07 -3.29E-07 1.92E-08 2.00E-08 2.12E-08 2.02E-08 2.05E-08 2.10E-08 1.93E-08 -2.56E-07 -2.65E-07 -2.70E-07 -2.76E-07 -2.90E-07 -2.89E-07 -2.76E-07 -3.61E-07 -3.74E-07 -3.86E-07 -3.87E-07 -4.02E-07 -4.04E-07 -3.82E-07 -3.03E-07 6.45E-09 -2.85E-07 -3.21E-07 -7.15E-07 PASS 7.15E-07 PASS -3.07E-07 6.86E-09 -2.88E-07 -3.25E-07 -7.65E-07 PASS 7.65E-07 PASS -3.13E-07 7.01E-09 -2.94E-07 -3.32E-07 -8.15E-07 PASS 8.15E-07 PASS -3.20E-07 6.72E-09 -3.01E-07 -3.38E-07 -8.15E-07 PASS 8.15E-07 PASS -3.36E-07 7.80E-09 -3.15E-07 -3.57E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 44 -3.36E-07 8.20E-09 -3.13E-07 -3.58E-07 -8.65E-07 PASS 8.65E-07 PASS -3.22E-07 6.17E-09 -3.05E-07 -3.38E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.17. Plot of -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 45 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.17. Raw data for -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.78E-07 -3.27E-07 -3.18E-07 -3.20E-07 -2.95E-07 -3.17E-07 -3.03E-07 -2.97E-07 -2.98E-07 -2.96E-07 -3.12E-07 -3.14E-07 10 -2.86E-07 -3.39E-07 -3.31E-07 -3.31E-07 -3.07E-07 -3.20E-07 -3.08E-07 -3.01E-07 -3.00E-07 -3.00E-07 -3.10E-07 -3.16E-07 Total Dose (krad(Si)) 20 30 -2.92E-07 -2.96E-07 -3.48E-07 -3.53E-07 -3.38E-07 -3.40E-07 -3.39E-07 -3.46E-07 -3.14E-07 -3.18E-07 -3.27E-07 -3.34E-07 -3.14E-07 -3.20E-07 -3.07E-07 -3.13E-07 -3.07E-07 -3.13E-07 -3.05E-07 -3.12E-07 -3.11E-07 -3.11E-07 -3.11E-07 -3.14E-07 50 -3.10E-07 -3.65E-07 -3.57E-07 -3.58E-07 -3.30E-07 -3.52E-07 -3.33E-07 -3.28E-07 -3.28E-07 -3.28E-07 -3.14E-07 -3.14E-07 24 Hr Anneal 60 -3.09E-07 -3.64E-07 -3.58E-07 -3.61E-07 -3.30E-07 -3.51E-07 -3.34E-07 -3.27E-07 -3.27E-07 -3.27E-07 -3.15E-07 -3.18E-07 168 Hr Anneal 70 -2.97E-07 -3.51E-07 -3.38E-07 -3.40E-07 -3.16E-07 -3.35E-07 -3.22E-07 -3.15E-07 -3.15E-07 -3.15E-07 -3.14E-07 -3.16E-07 -3.08E-07 -3.19E-07 -3.26E-07 -3.31E-07 -3.44E-07 -3.45E-07 -3.28E-07 2.07E-08 2.21E-08 2.30E-08 2.34E-08 2.31E-08 2.41E-08 2.15E-08 -2.51E-07 -2.58E-07 -2.63E-07 -2.66E-07 -2.81E-07 -2.79E-07 -2.69E-07 -3.64E-07 -3.79E-07 -3.89E-07 -3.95E-07 -4.08E-07 -4.11E-07 -3.87E-07 -3.02E-07 8.50E-09 -2.79E-07 -3.25E-07 -7.15E-07 PASS 7.15E-07 PASS -3.06E-07 8.88E-09 -2.81E-07 -3.30E-07 -7.65E-07 PASS 7.65E-07 PASS -3.12E-07 8.94E-09 -2.88E-07 -3.37E-07 -8.15E-07 PASS 8.15E-07 PASS -3.18E-07 9.10E-09 -2.93E-07 -3.43E-07 -8.15E-07 PASS 8.15E-07 PASS -3.34E-07 1.06E-08 -3.05E-07 -3.63E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 46 -3.33E-07 1.05E-08 -3.04E-07 -3.62E-07 -8.65E-07 PASS 8.65E-07 PASS -3.20E-07 8.58E-09 -2.97E-07 -3.44E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.18. Plot of -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 47 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.18. Raw data for -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.87E-07 -3.05E-07 -3.19E-07 -3.30E-07 -3.11E-07 -3.16E-07 -3.07E-07 -3.05E-07 -3.18E-07 -3.07E-07 -2.78E-07 -2.90E-07 10 -2.95E-07 -3.16E-07 -3.32E-07 -3.40E-07 -3.24E-07 -3.19E-07 -3.11E-07 -3.10E-07 -3.20E-07 -3.10E-07 -2.77E-07 -2.91E-07 Total Dose (krad(Si)) 20 30 -3.02E-07 -3.07E-07 -3.23E-07 -3.27E-07 -3.38E-07 -3.40E-07 -3.54E-07 -3.56E-07 -3.32E-07 -3.36E-07 -3.25E-07 -3.31E-07 -3.18E-07 -3.25E-07 -3.16E-07 -3.23E-07 -3.27E-07 -3.34E-07 -3.16E-07 -3.23E-07 -2.78E-07 -2.78E-07 -2.87E-07 -2.90E-07 50 -3.22E-07 -3.41E-07 -3.58E-07 -3.68E-07 -3.55E-07 -3.48E-07 -3.40E-07 -3.39E-07 -3.53E-07 -3.38E-07 -2.80E-07 -2.90E-07 24 Hr Anneal 60 -3.21E-07 -3.40E-07 -3.58E-07 -3.69E-07 -3.52E-07 -3.48E-07 -3.40E-07 -3.39E-07 -3.53E-07 -3.37E-07 -2.82E-07 -2.94E-07 168 Hr Anneal 70 -3.08E-07 -3.24E-07 -3.39E-07 -3.52E-07 -3.32E-07 -3.32E-07 -3.26E-07 -3.26E-07 -3.36E-07 -3.24E-07 -2.81E-07 -2.92E-07 -3.10E-07 -3.22E-07 -3.30E-07 -3.33E-07 -3.49E-07 -3.48E-07 -3.31E-07 1.60E-08 1.72E-08 1.92E-08 1.81E-08 1.79E-08 1.83E-08 1.64E-08 -2.66E-07 -2.74E-07 -2.77E-07 -2.84E-07 -3.00E-07 -2.98E-07 -2.86E-07 -3.54E-07 -3.69E-07 -3.83E-07 -3.83E-07 -3.98E-07 -3.98E-07 -3.76E-07 -3.11E-07 5.96E-09 -2.94E-07 -3.27E-07 -7.15E-07 PASS 7.15E-07 PASS -3.14E-07 5.27E-09 -3.00E-07 -3.29E-07 -7.65E-07 PASS 7.65E-07 PASS -3.20E-07 5.51E-09 -3.05E-07 -3.36E-07 -8.15E-07 PASS 8.15E-07 PASS -3.27E-07 5.25E-09 -3.13E-07 -3.41E-07 -8.15E-07 PASS 8.15E-07 PASS -3.44E-07 6.59E-09 -3.26E-07 -3.62E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 48 -3.43E-07 6.77E-09 -3.25E-07 -3.62E-07 -8.65E-07 PASS 8.65E-07 PASS -3.29E-07 4.96E-09 -3.15E-07 -3.42E-07 -8.65E-07 PASS 8.65E-07 PASS Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.19. Plot of Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 49 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.19. Raw data for Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 8.45E-05 -1.02E-05 2.28E-04 3.57E-05 1.80E-04 1.58E-04 -7.94E-05 4.02E-04 -5.96E-05 8.84E-05 -2.62E-04 2.31E-04 Total Dose (krad(Si)) 20 30 6.92E-05 6.52E-05 -1.98E-05 -2.22E-05 2.18E-04 2.20E-04 1.92E-05 1.88E-05 1.73E-04 1.75E-04 1.49E-04 1.48E-04 -8.16E-05 -8.24E-05 3.93E-04 3.92E-04 -6.30E-05 -6.50E-05 8.30E-05 8.14E-05 -2.58E-04 -2.57E-04 2.37E-04 2.34E-04 10 7.25E-05 -1.72E-05 2.19E-04 2.40E-05 1.70E-04 1.49E-04 -8.51E-05 3.93E-04 -6.44E-05 8.07E-05 -2.59E-04 2.33E-04 50 5.48E-05 -2.48E-05 2.16E-04 1.87E-05 1.72E-04 1.44E-04 -8.00E-05 3.92E-04 -6.44E-05 7.88E-05 -2.58E-04 2.36E-04 24 Hr Anneal 60 5.85E-05 -2.29E-05 2.16E-04 2.13E-05 1.74E-04 1.46E-04 -7.93E-05 3.94E-04 -6.33E-05 7.90E-05 -2.58E-04 2.32E-04 168 Hr Anneal 70 6.01E-05 -3.12E-05 2.14E-04 1.61E-05 1.68E-04 1.37E-04 -8.25E-05 3.82E-04 -7.11E-05 8.18E-05 -2.56E-04 2.34E-04 1.04E-04 9.38E-05 9.20E-05 9.13E-05 8.73E-05 8.92E-05 8.55E-05 9.90E-05 9.90E-05 1.01E-04 1.03E-04 1.03E-04 1.01E-04 1.03E-04 3.75E-04 3.65E-04 3.69E-04 3.73E-04 3.69E-04 3.67E-04 3.68E-04 -1.68E-04 -1.78E-04 -1.85E-04 -1.91E-04 -1.94E-04 -1.89E-04 -1.97E-04 1.02E-04 1.95E-04 6.37E-04 -4.33E-04 -8.00E-04 PASS 8.00E-04 PASS 9.46E-05 1.94E-04 6.25E-04 -4.36E-04 -9.50E-04 PASS 9.50E-04 PASS 9.62E-05 1.92E-04 6.24E-04 -4.32E-04 -9.50E-04 PASS 9.50E-04 PASS 9.48E-05 1.93E-04 6.23E-04 -4.33E-04 -9.50E-04 PASS 9.50E-04 PASS 9.42E-05 1.92E-04 6.20E-04 -4.31E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 50 9.52E-05 1.92E-04 6.22E-04 -4.31E-04 -9.50E-04 PASS 9.50E-04 PASS 8.95E-05 1.89E-04 6.09E-04 -4.29E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.20. Plot of Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 51 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.20. Raw data for Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 24 Hr 168 Hr Anneal Anneal Total Dose (krad(Si)) 20 30 50 60 70 4.67E-05 4.63E-05 4.26E-05 4.41E-05 4.35E-05 -9.88E-05 -1.01E-04 -1.02E-04 -9.74E-05 -1.01E-04 1.46E-04 1.45E-04 1.40E-04 1.43E-04 1.44E-04 7.61E-05 7.66E-05 7.34E-05 7.39E-05 7.99E-05 3.30E-04 3.29E-04 3.26E-04 3.29E-04 3.22E-04 -3.71E-05 -3.73E-05 -3.52E-05 -3.21E-05 -3.73E-05 8.70E-05 8.92E-05 8.86E-05 9.41E-05 7.95E-05 2.32E-04 2.30E-04 2.26E-04 2.30E-04 2.23E-04 1.03E-04 1.03E-04 1.08E-04 1.07E-04 9.89E-05 -1.02E-04 -1.03E-04 -1.03E-04 -1.00E-04 -1.01E-04 8.82E-05 9.00E-05 8.89E-05 9.07E-05 9.12E-05 3.19E-04 3.16E-04 3.21E-04 3.14E-04 3.18E-04 0 10 5.94E-05 4.88E-05 -9.16E-05 -9.82E-05 1.51E-04 1.44E-04 8.41E-05 7.84E-05 3.38E-04 3.34E-04 -3.28E-05 -3.76E-05 8.96E-05 8.69E-05 2.47E-04 2.35E-04 1.03E-04 1.00E-04 -1.02E-04 -1.03E-04 8.57E-05 8.83E-05 3.15E-04 3.17E-04 1.08E-04 1.01E-04 9.98E-05 9.92E-05 9.61E-05 9.86E-05 9.75E-05 1.56E-04 1.57E-04 1.56E-04 1.57E-04 1.56E-04 1.56E-04 1.54E-04 5.37E-04 5.32E-04 5.28E-04 5.29E-04 5.24E-04 5.26E-04 5.21E-04 -3.20E-04 -3.30E-04 -3.29E-04 -3.31E-04 -3.32E-04 -3.29E-04 -3.26E-04 6.11E-05 1.35E-04 4.30E-04 -3.08E-04 -8.00E-04 PASS 8.00E-04 PASS 5.63E-05 1.31E-04 4.16E-04 -3.03E-04 -9.50E-04 PASS 9.50E-04 PASS 5.66E-05 1.30E-04 4.14E-04 -3.01E-04 -9.50E-04 PASS 9.50E-04 PASS 5.64E-05 1.30E-04 4.13E-04 -3.01E-04 -9.50E-04 PASS 9.50E-04 PASS 5.69E-05 1.29E-04 4.10E-04 -2.96E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 52 5.98E-05 1.29E-04 4.13E-04 -2.93E-04 -9.50E-04 PASS 9.50E-04 PASS 5.27E-05 1.26E-04 3.98E-04 -2.93E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.21. Plot of Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 53 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.21. Raw data for Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 24 Hr 168 Hr Anneal Anneal Total Dose (krad(Si)) 20 30 50 60 70 5.31E-04 5.27E-04 5.23E-04 5.23E-04 5.17E-04 1.59E-04 1.57E-04 1.56E-04 1.59E-04 1.61E-04 2.04E-04 2.05E-04 2.00E-04 2.00E-04 1.92E-04 1.86E-04 1.85E-04 1.81E-04 1.82E-04 1.75E-04 -2.18E-05 -2.46E-05 -2.72E-05 -2.71E-05 -2.68E-05 1.56E-04 1.55E-04 1.51E-04 1.52E-04 1.40E-04 9.11E-05 9.07E-05 8.65E-05 8.80E-05 9.27E-05 2.23E-04 2.21E-04 2.19E-04 2.20E-04 2.07E-04 1.63E-04 1.63E-04 1.60E-04 1.62E-04 1.64E-04 6.07E-05 5.76E-05 5.78E-05 5.95E-05 6.36E-05 4.04E-04 4.05E-04 4.06E-04 4.04E-04 4.05E-04 1.81E-04 1.81E-04 1.85E-04 1.79E-04 1.81E-04 0 10 5.47E-04 5.35E-04 1.68E-04 1.60E-04 2.16E-04 2.09E-04 2.00E-04 1.92E-04 -1.24E-05 -1.75E-05 1.64E-04 1.57E-04 9.88E-05 9.07E-05 2.33E-04 2.27E-04 1.68E-04 1.64E-04 6.46E-05 6.10E-05 3.99E-04 4.03E-04 1.79E-04 1.82E-04 2.24E-04 2.16E-04 2.12E-04 2.10E-04 2.07E-04 2.07E-04 2.04E-04 2.02E-04 2.00E-04 2.00E-04 1.99E-04 1.99E-04 1.98E-04 1.96E-04 7.79E-04 7.64E-04 7.61E-04 7.57E-04 7.52E-04 7.51E-04 7.42E-04 -3.31E-04 -3.33E-04 -3.37E-04 -3.37E-04 -3.39E-04 -3.37E-04 -3.34E-04 1.46E-04 6.57E-05 3.26E-04 -3.44E-05 -8.00E-04 PASS 8.00E-04 PASS 1.40E-04 6.52E-05 3.19E-04 -3.91E-05 -9.50E-04 PASS 9.50E-04 PASS 1.39E-04 6.38E-05 3.14E-04 -3.63E-05 -9.50E-04 PASS 9.50E-04 PASS 1.37E-04 6.42E-05 3.13E-04 -3.86E-05 -9.50E-04 PASS 9.50E-04 PASS 1.35E-04 6.38E-05 3.10E-04 -3.99E-05 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 54 1.36E-04 6.36E-05 3.11E-04 -3.81E-05 -9.50E-04 PASS 9.50E-04 PASS 1.34E-04 5.70E-05 2.90E-04 -2.26E-05 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.22. Plot of Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 55 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.22. Raw data for Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 24 Hr 168 Hr Anneal Anneal Total Dose (krad(Si)) 20 30 50 60 70 -2.17E-04 -2.19E-04 -2.22E-04 -2.20E-04 -2.14E-04 1.05E-04 1.05E-04 1.01E-04 1.02E-04 1.06E-04 1.08E-04 1.09E-04 1.05E-04 1.04E-04 9.29E-05 1.05E-04 1.05E-04 1.04E-04 1.05E-04 9.81E-05 -2.05E-04 -2.08E-04 -2.06E-04 -2.04E-04 -2.14E-04 1.17E-04 1.22E-04 1.29E-04 1.28E-04 1.26E-04 3.03E-04 3.04E-04 3.05E-04 3.05E-04 2.95E-04 9.04E-05 9.28E-05 9.34E-05 9.63E-05 9.43E-05 1.26E-04 1.28E-04 1.31E-04 1.30E-04 1.25E-04 3.16E-05 3.17E-05 3.13E-05 3.51E-05 3.31E-05 3.10E-04 3.11E-04 3.09E-04 3.07E-04 3.09E-04 1.50E-05 1.33E-05 1.62E-05 1.33E-05 1.26E-05 0 10 -2.06E-04 -2.15E-04 1.16E-04 1.07E-04 1.17E-04 1.09E-04 1.11E-04 1.05E-04 -1.95E-04 -2.03E-04 1.22E-04 1.16E-04 3.10E-04 3.01E-04 9.69E-05 9.05E-05 1.29E-04 1.23E-04 3.59E-05 2.94E-05 3.07E-04 3.10E-04 4.52E-06 1.31E-05 -1.14E-05 -1.93E-05 -2.06E-05 -2.16E-05 -2.37E-05 -2.25E-05 -2.64E-05 1.73E-04 1.73E-04 1.74E-04 1.75E-04 1.74E-04 1.73E-04 1.72E-04 4.62E-04 4.55E-04 4.56E-04 4.58E-04 4.54E-04 4.52E-04 4.45E-04 -4.85E-04 -4.94E-04 -4.97E-04 -5.02E-04 -5.01E-04 -4.97E-04 -4.97E-04 1.39E-04 1.03E-04 4.20E-04 -1.42E-04 -8.00E-04 PASS 8.00E-04 PASS 1.32E-04 1.01E-04 4.10E-04 -1.46E-04 -9.50E-04 PASS 9.50E-04 PASS 1.34E-04 1.02E-04 4.12E-04 -1.45E-04 -9.50E-04 PASS 9.50E-04 PASS 1.36E-04 1.02E-04 4.15E-04 -1.43E-04 -9.50E-04 PASS 9.50E-04 PASS 1.38E-04 1.02E-04 4.17E-04 -1.41E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 56 1.39E-04 1.00E-04 4.14E-04 -1.37E-04 -9.50E-04 PASS 9.50E-04 PASS 1.35E-04 9.71E-05 4.01E-04 -1.32E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.23. Plot of Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 57 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.23. Raw data for Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -9.12E-09 -8.70E-10 -3.13E-09 -2.00E-09 1.15E-08 -1.01E-09 1.09E-08 -1.13E-09 -1.50E-09 1.07E-08 -9.30E-10 9.40E-10 10 -1.07E-08 -2.82E-09 -4.97E-09 -4.40E-09 9.29E-09 1.00E-11 1.27E-08 1.00E-09 -9.00E-10 1.18E-08 2.21E-09 5.93E-09 Total Dose 20 -1.32E-08 -5.42E-09 -7.58E-09 -6.62E-09 7.28E-09 5.80E-10 1.40E-08 1.82E-09 1.50E-10 1.22E-08 3.53E-09 7.11E-09 (krad(Si)) 30 -1.53E-08 -7.14E-09 -7.61E-09 -7.69E-09 7.31E-09 8.10E-10 1.47E-08 2.60E-09 1.14E-09 1.32E-08 4.59E-09 7.05E-09 50 -2.14E-08 -9.86E-09 -8.84E-09 -1.01E-08 3.48E-09 6.30E-10 1.60E-08 3.62E-09 3.06E-09 1.41E-08 4.98E-09 6.80E-09 24 Hr Anneal 60 -1.85E-08 -7.84E-09 -7.38E-09 -7.78E-09 6.56E-09 2.71E-09 1.77E-08 4.74E-09 3.83E-09 1.49E-08 5.70E-09 6.54E-09 168 Hr Anneal 70 -1.84E-08 -9.04E-09 -9.07E-09 -8.97E-09 4.93E-09 1.30E-10 1.36E-08 2.88E-09 3.00E-10 1.32E-08 6.64E-09 7.25E-09 -7.22E-10 -2.72E-09 -5.10E-09 -6.09E-09 -9.34E-09 -6.99E-09 -8.10E-09 7.54E-09 7.34E-09 7.53E-09 8.23E-09 8.81E-09 8.91E-09 8.33E-09 2.00E-08 1.74E-08 1.55E-08 1.65E-08 1.48E-08 1.74E-08 1.47E-08 -2.14E-08 -2.28E-08 -2.57E-08 -2.87E-08 -3.35E-08 -3.14E-08 -3.10E-08 3.58E-09 6.57E-09 2.16E-08 -1.44E-08 -7.00E-08 PASS 7.00E-08 PASS 4.92E-09 6.73E-09 2.34E-08 -1.35E-08 -1.00E-07 PASS 1.00E-07 PASS 5.73E-09 6.75E-09 2.42E-08 -1.28E-08 -1.00E-07 PASS 1.00E-07 PASS 6.49E-09 6.86E-09 2.53E-08 -1.23E-08 -1.00E-07 PASS 1.00E-07 PASS 7.47E-09 7.02E-09 2.67E-08 -1.18E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 58 8.78E-09 6.99E-09 2.79E-08 -1.04E-08 -1.00E-07 PASS 1.00E-07 PASS 6.02E-09 6.82E-09 2.47E-08 -1.27E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.24. Plot of Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 59 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.24. Raw data for Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 10 5.23E-09 3.90E-09 1.74E-09 9.70E-10 3.31E-09 1.41E-09 1.21E-08 8.96E-09 2.92E-09 7.00E-11 -2.03E-09 -1.37E-09 5.25E-09 6.27E-09 2.56E-09 4.23E-09 4.86E-09 6.18E-09 1.57E-08 1.69E-08 2.64E-09 4.85E-09 1.36E-08 1.90E-08 Total Dose 20 2.02E-09 -6.10E-10 1.50E-10 6.96E-09 -2.12E-09 -9.90E-10 6.43E-09 4.49E-09 7.22E-09 1.75E-08 6.33E-09 1.92E-08 (krad(Si)) 30 2.70E-10 -2.27E-09 -8.40E-10 6.48E-09 -3.41E-09 -9.70E-10 7.18E-09 4.43E-09 8.52E-09 1.78E-08 7.25E-09 1.91E-08 50 -2.00E-09 -4.10E-09 -2.74E-09 4.85E-09 -6.04E-09 -3.80E-10 5.92E-09 4.19E-09 9.19E-09 1.72E-08 7.59E-09 1.94E-08 24 Hr Anneal 60 -4.20E-10 -2.14E-09 -3.90E-10 6.56E-09 -2.93E-09 1.52E-09 8.17E-09 6.48E-09 1.05E-08 1.93E-08 8.17E-09 1.95E-08 168 Hr Anneal 70 -1.44E-09 -4.15E-09 -1.91E-09 4.19E-09 -5.05E-09 -1.31E-09 6.18E-09 2.45E-09 7.08E-09 1.72E-08 9.35E-09 1.99E-08 5.06E-09 3.06E-09 1.28E-09 4.60E-11 -2.01E-09 1.36E-10 -1.67E-09 4.14E-09 3.59E-09 3.51E-09 3.86E-09 4.13E-09 3.76E-09 3.61E-09 1.64E-08 1.29E-08 1.09E-08 1.06E-08 9.32E-09 1.04E-08 8.22E-09 -6.28E-09 -6.78E-09 -8.34E-09 -1.05E-08 -1.33E-08 -1.02E-08 -1.16E-08 5.26E-09 6.50E-09 2.31E-08 -1.26E-08 -7.00E-08 PASS 7.00E-08 PASS 6.44E-09 6.62E-09 2.46E-08 -1.17E-08 -1.00E-07 PASS 1.00E-07 PASS 6.93E-09 6.72E-09 2.53E-08 -1.15E-08 -1.00E-07 PASS 1.00E-07 PASS 7.40E-09 6.87E-09 2.62E-08 -1.14E-08 -1.00E-07 PASS 1.00E-07 PASS 7.22E-09 6.56E-09 2.52E-08 -1.08E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 60 9.19E-09 6.53E-09 2.71E-08 -8.71E-09 -1.00E-07 PASS 1.00E-07 PASS 6.32E-09 6.92E-09 2.53E-08 -1.27E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.25. Plot of Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 61 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.25. Raw data for Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 10 1.10E-08 1.01E-08 5.99E-09 4.21E-09 2.42E-09 -5.60E-10 4.05E-09 4.90E-10 1.33E-08 9.15E-09 7.69E-09 8.38E-09 4.87E-09 5.15E-09 -7.59E-09 -6.04E-09 4.53E-09 4.64E-09 -6.50E-10 -6.00E-11 1.56E-08 1.78E-08 6.08E-09 1.21E-08 Total Dose 20 7.09E-09 3.58E-09 -2.41E-09 -2.02E-09 7.08E-09 9.57E-09 5.57E-09 -6.11E-09 5.23E-09 6.20E-10 1.90E-08 1.24E-08 (krad(Si)) 30 4.79E-09 2.08E-09 -2.93E-09 -2.16E-09 5.94E-09 1.00E-08 6.23E-09 -4.78E-09 5.38E-09 6.00E-11 1.96E-08 1.21E-08 50 1.84E-09 -2.70E-10 -6.03E-09 -5.55E-09 1.10E-09 8.87E-09 4.21E-09 -6.58E-09 3.25E-09 -1.78E-09 1.89E-08 1.06E-08 24 Hr Anneal 60 3.04E-09 1.25E-09 -3.93E-09 -3.88E-09 3.82E-09 1.06E-08 5.67E-09 -4.06E-09 5.79E-09 2.60E-10 2.01E-08 1.10E-08 168 Hr Anneal 70 1.78E-09 -1.36E-09 -2.10E-09 -5.31E-09 2.89E-09 8.39E-09 4.33E-09 -8.41E-09 3.26E-09 -1.18E-09 2.10E-08 1.16E-08 7.33E-09 4.67E-09 2.66E-09 1.54E-09 -1.78E-09 6.00E-11 -8.20E-10 4.60E-09 4.85E-09 4.68E-09 4.00E-09 3.74E-09 3.74E-09 3.26E-09 2.00E-08 1.80E-08 1.55E-08 1.25E-08 8.47E-09 1.03E-08 8.13E-09 -5.29E-09 -8.64E-09 -1.02E-08 -9.41E-09 -1.20E-08 -1.02E-08 -9.77E-09 1.77E-09 6.04E-09 1.83E-08 -1.48E-08 -7.00E-08 PASS 7.00E-08 PASS 2.41E-09 5.60E-09 1.78E-08 -1.30E-08 -1.00E-07 PASS 1.00E-07 PASS 2.98E-09 5.99E-09 1.94E-08 -1.34E-08 -1.00E-07 PASS 1.00E-07 PASS 3.38E-09 5.78E-09 1.92E-08 -1.25E-08 -1.00E-07 PASS 1.00E-07 PASS 1.59E-09 5.93E-09 1.79E-08 -1.47E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 62 3.66E-09 5.66E-09 1.92E-08 -1.19E-08 -1.00E-07 PASS 1.00E-07 PASS 1.28E-09 6.40E-09 1.88E-08 -1.63E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.26. Plot of Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 63 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.26. Raw data for Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -4.46E-09 -5.78E-09 -2.98E-09 -2.11E-09 -7.44E-09 3.39E-09 -1.04E-08 1.30E-08 -5.01E-09 3.60E-10 -3.69E-09 -9.39E-09 10 -2.21E-09 -4.45E-09 -2.52E-09 -1.83E-09 -7.95E-09 7.37E-09 -6.00E-09 1.89E-08 -6.10E-10 4.73E-09 2.33E-09 8.40E-10 Total Dose 20 -3.42E-09 -5.50E-09 -4.19E-09 -3.07E-09 -9.99E-09 9.97E-09 -4.10E-09 2.08E-08 9.00E-10 5.95E-09 4.89E-09 2.79E-09 (krad(Si)) 30 -4.74E-09 -6.32E-09 -4.95E-09 -3.99E-09 -9.94E-09 1.09E-08 -2.59E-09 2.25E-08 1.50E-09 5.63E-09 6.33E-09 3.16E-09 50 -8.64E-09 -9.23E-09 -6.83E-09 -4.94E-09 -1.21E-08 1.23E-08 -1.60E-09 2.53E-08 3.09E-09 7.13E-09 6.98E-09 3.71E-09 24 Hr Anneal 60 -6.48E-09 -7.11E-09 -4.60E-09 -2.23E-09 -1.03E-08 1.38E-08 6.50E-10 2.76E-08 4.05E-09 9.23E-09 7.58E-09 2.99E-09 168 Hr Anneal 70 -7.54E-09 -7.11E-09 -5.91E-09 -3.69E-09 -1.18E-08 1.05E-08 -3.25E-09 2.23E-08 1.00E-09 6.94E-09 8.56E-09 4.06E-09 -4.55E-09 -3.79E-09 -5.23E-09 -5.99E-09 -8.34E-09 -6.14E-09 -7.20E-09 2.14E-09 2.53E-09 2.82E-09 2.36E-09 2.68E-09 3.00E-09 2.95E-09 1.31E-09 3.16E-09 2.49E-09 4.94E-10 -9.98E-10 2.08E-09 8.89E-10 -1.04E-08 -1.07E-08 -1.30E-08 -1.25E-08 -1.57E-08 -1.44E-08 -1.53E-08 2.62E-10 8.84E-09 2.45E-08 -2.40E-08 -7.00E-08 PASS 7.00E-08 PASS 4.87E-09 9.36E-09 3.05E-08 -2.08E-08 -1.00E-07 PASS 1.00E-07 PASS 6.71E-09 9.50E-09 3.28E-08 -1.93E-08 -1.00E-07 PASS 1.00E-07 PASS 7.59E-09 9.72E-09 3.42E-08 -1.91E-08 -1.00E-07 PASS 1.00E-07 PASS 9.24E-09 1.03E-08 3.75E-08 -1.90E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 64 1.11E-08 1.05E-08 3.99E-08 -1.77E-08 -1.00E-07 PASS 1.00E-07 PASS 7.50E-09 9.83E-09 3.45E-08 -1.95E-08 -1.00E-07 PASS 1.00E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.27. Plot of +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 65 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.27. Raw data for +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V Device 0 10 557 3.41E-07 3.54E-07 563 3.38E-07 3.64E-07 564 3.51E-07 3.77E-07 567 3.40E-07 3.64E-07 569 3.54E-07 3.82E-07 570 3.38E-07 3.46E-07 571 3.42E-07 3.53E-07 572 3.47E-07 3.57E-07 573 3.36E-07 3.41E-07 574 3.44E-07 3.49E-07 584 3.28E-07 3.31E-07 585 3.46E-07 3.53E-07 Biased Statistics Average Biased 3.45E-07 3.68E-07 Std Dev Biased 7.20E-09 1.11E-08 Ps90%/90% (+KTL) Biased 3.64E-07 3.98E-07 Ps90%/90% (-KTL) Biased 3.25E-07 3.38E-07 Un-Biased Statistics Average Un-Biased 3.41E-07 3.49E-07 Std Dev Un-Biased 4.30E-09 6.27E-09 Ps90%/90% (+KTL) Un-Biased 3.53E-07 3.67E-07 Ps90%/90% (-KTL) Un-Biased 3.30E-07 3.32E-07 Specification MIN -7.15E-07 -7.65E-07 Status PASS PASS Specification MAX 7.15E-07 7.65E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.73E-07 3.88E-07 3.81E-07 3.91E-07 3.97E-07 4.08E-07 3.85E-07 3.97E-07 4.03E-07 4.16E-07 3.62E-07 3.79E-07 3.69E-07 3.88E-07 3.75E-07 3.95E-07 3.54E-07 3.74E-07 3.64E-07 3.85E-07 3.32E-07 3.33E-07 3.49E-07 3.55E-07 3.88E-07 1.22E-08 4.21E-07 3.55E-07 4.00E-07 1.18E-08 4.33E-07 3.68E-07 168 Hr Anneal 70 3.89E-07 3.90E-07 4.05E-07 3.92E-07 4.11E-07 3.87E-07 3.97E-07 4.07E-07 3.84E-07 3.94E-07 3.37E-07 3.55E-07 4.29E-07 1.03E-08 4.57E-07 4.01E-07 4.29E-07 1.17E-08 4.61E-07 3.97E-07 3.97E-07 1.02E-08 4.25E-07 3.70E-07 3.65E-07 3.84E-07 4.21E-07 4.21E-07 3.93E-07 7.84E-09 8.00E-09 7.98E-09 8.79E-09 9.05E-09 3.86E-07 4.06E-07 4.43E-07 4.45E-07 4.18E-07 3.43E-07 3.62E-07 3.99E-07 3.97E-07 3.69E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07 PASS PASS PASS PASS PASS 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 66 50 4.19E-07 4.22E-07 4.36E-07 4.23E-07 4.43E-07 4.16E-07 4.24E-07 4.33E-07 4.12E-07 4.21E-07 3.35E-07 3.57E-07 24 Hr Anneal 60 4.19E-07 4.22E-07 4.37E-07 4.21E-07 4.45E-07 4.16E-07 4.26E-07 4.34E-07 4.12E-07 4.20E-07 3.37E-07 3.60E-07 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.28. Plot of +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 67 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.28. Raw data for +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V Device 0 10 557 3.37E-07 3.50E-07 563 3.45E-07 3.70E-07 564 3.48E-07 3.73E-07 567 3.45E-07 3.70E-07 569 3.40E-07 3.64E-07 570 3.41E-07 3.45E-07 571 3.38E-07 3.44E-07 572 3.37E-07 3.42E-07 573 3.28E-07 3.33E-07 574 3.51E-07 3.56E-07 584 3.44E-07 3.48E-07 585 3.53E-07 3.61E-07 Biased Statistics Average Biased 3.43E-07 3.65E-07 Std Dev Biased 4.57E-09 9.37E-09 Ps90%/90% (+KTL) Biased 3.56E-07 3.91E-07 Ps90%/90% (-KTL) Biased 3.31E-07 3.40E-07 Un-Biased Statistics Average Un-Biased 3.39E-07 3.44E-07 Std Dev Un-Biased 8.04E-09 8.27E-09 Ps90%/90% (+KTL) Un-Biased 3.61E-07 3.67E-07 Ps90%/90% (-KTL) Un-Biased 3.17E-07 3.21E-07 Specification MIN -7.15E-07 -7.65E-07 Status PASS PASS Specification MAX 7.15E-07 7.65E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.71E-07 3.87E-07 3.87E-07 4.00E-07 3.94E-07 4.05E-07 3.89E-07 4.01E-07 3.86E-07 3.98E-07 3.61E-07 3.80E-07 3.58E-07 3.77E-07 3.58E-07 3.78E-07 3.46E-07 3.64E-07 3.74E-07 3.94E-07 3.50E-07 3.49E-07 3.58E-07 3.63E-07 3.85E-07 8.50E-09 4.09E-07 3.62E-07 3.98E-07 6.83E-09 4.17E-07 3.79E-07 168 Hr Anneal 70 3.89E-07 3.96E-07 4.02E-07 3.96E-07 3.92E-07 3.89E-07 3.87E-07 3.86E-07 3.74E-07 4.04E-07 3.52E-07 3.62E-07 4.26E-07 4.72E-09 4.39E-07 4.13E-07 4.26E-07 5.72E-09 4.42E-07 4.11E-07 3.95E-07 5.03E-09 4.09E-07 3.81E-07 3.59E-07 3.79E-07 4.16E-07 4.15E-07 3.88E-07 9.75E-09 1.06E-08 1.19E-08 1.15E-08 1.07E-08 3.86E-07 4.08E-07 4.48E-07 4.47E-07 4.17E-07 3.33E-07 3.50E-07 3.83E-07 3.84E-07 3.58E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07 PASS PASS PASS PASS PASS 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 68 50 4.22E-07 4.25E-07 4.34E-07 4.28E-07 4.23E-07 4.17E-07 4.13E-07 4.14E-07 4.01E-07 4.34E-07 3.51E-07 3.64E-07 24 Hr Anneal 60 4.19E-07 4.26E-07 4.35E-07 4.26E-07 4.25E-07 4.16E-07 4.13E-07 4.16E-07 3.99E-07 4.31E-07 3.51E-07 3.66E-07 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.29. Plot of +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 69 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.29. Raw data for +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V Device 0 10 557 3.49E-07 3.62E-07 563 3.59E-07 3.78E-07 564 3.69E-07 3.93E-07 567 3.38E-07 3.60E-07 569 3.51E-07 3.76E-07 570 3.46E-07 3.53E-07 571 3.39E-07 3.41E-07 572 3.43E-07 3.51E-07 573 3.29E-07 3.31E-07 574 3.55E-07 3.59E-07 584 3.55E-07 3.57E-07 585 3.57E-07 3.63E-07 Biased Statistics Average Biased 3.53E-07 3.74E-07 Std Dev Biased 1.14E-08 1.33E-08 Ps90%/90% (+KTL) Biased 3.85E-07 4.10E-07 Ps90%/90% (-KTL) Biased 3.22E-07 3.37E-07 Un-Biased Statistics Average Un-Biased 3.42E-07 3.47E-07 Std Dev Un-Biased 9.43E-09 1.09E-08 Ps90%/90% (+KTL) Un-Biased 3.68E-07 3.77E-07 Ps90%/90% (-KTL) Un-Biased 3.16E-07 3.17E-07 Specification MIN -7.15E-07 -7.65E-07 Status PASS PASS Specification MAX 7.15E-07 7.65E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.83E-07 3.96E-07 3.95E-07 4.06E-07 4.12E-07 4.21E-07 3.79E-07 3.91E-07 3.96E-07 4.08E-07 3.67E-07 3.85E-07 3.57E-07 3.73E-07 3.67E-07 3.87E-07 3.42E-07 3.61E-07 3.75E-07 3.93E-07 3.58E-07 3.57E-07 3.58E-07 3.63E-07 3.93E-07 1.30E-08 4.29E-07 3.57E-07 4.05E-07 1.17E-08 4.37E-07 3.73E-07 168 Hr Anneal 70 3.95E-07 4.02E-07 4.16E-07 3.83E-07 4.02E-07 3.91E-07 3.81E-07 3.92E-07 3.69E-07 4.05E-07 3.58E-07 3.60E-07 4.31E-07 1.25E-08 4.65E-07 3.97E-07 4.31E-07 1.32E-08 4.67E-07 3.95E-07 4.00E-07 1.19E-08 4.32E-07 3.67E-07 3.62E-07 3.80E-07 4.15E-07 4.15E-07 3.87E-07 1.27E-08 1.30E-08 1.55E-08 1.53E-08 1.36E-08 3.96E-07 4.15E-07 4.58E-07 4.57E-07 4.25E-07 3.27E-07 3.44E-07 3.73E-07 3.72E-07 3.50E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07 PASS PASS PASS PASS PASS 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 70 50 4.26E-07 4.35E-07 4.48E-07 4.14E-07 4.32E-07 4.20E-07 4.08E-07 4.20E-07 3.93E-07 4.35E-07 3.57E-07 3.64E-07 24 Hr Anneal 60 4.26E-07 4.33E-07 4.49E-07 4.13E-07 4.33E-07 4.19E-07 4.07E-07 4.22E-07 3.92E-07 4.32E-07 3.58E-07 3.65E-07 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.30. Plot of +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 71 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.30. Raw data for +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V Device 0 10 557 3.39E-07 3.48E-07 563 3.41E-07 3.65E-07 564 3.47E-07 3.72E-07 567 3.48E-07 3.73E-07 569 3.44E-07 3.71E-07 570 3.51E-07 3.57E-07 571 3.35E-07 3.41E-07 572 3.63E-07 3.73E-07 573 3.41E-07 3.42E-07 574 3.40E-07 3.46E-07 584 3.33E-07 3.36E-07 585 3.45E-07 3.54E-07 Biased Statistics Average Biased 3.44E-07 3.66E-07 Std Dev Biased 3.83E-09 1.04E-08 Ps90%/90% (+KTL) Biased 3.54E-07 3.95E-07 Ps90%/90% (-KTL) Biased 3.33E-07 3.38E-07 Un-Biased Statistics Average Un-Biased 3.46E-07 3.52E-07 Std Dev Un-Biased 1.12E-08 1.37E-08 Ps90%/90% (+KTL) Un-Biased 3.76E-07 3.89E-07 Ps90%/90% (-KTL) Un-Biased 3.15E-07 3.14E-07 Specification MIN -7.15E-07 -7.65E-07 Status PASS PASS Specification MAX 7.15E-07 7.65E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.69E-07 3.84E-07 3.82E-07 3.96E-07 3.92E-07 4.02E-07 3.93E-07 4.06E-07 3.94E-07 4.04E-07 3.75E-07 3.91E-07 3.57E-07 3.77E-07 3.90E-07 4.11E-07 3.58E-07 3.78E-07 3.61E-07 3.81E-07 3.37E-07 3.38E-07 3.51E-07 3.56E-07 3.86E-07 1.08E-08 4.16E-07 3.57E-07 3.99E-07 8.86E-09 4.23E-07 3.74E-07 168 Hr Anneal 70 3.86E-07 3.95E-07 3.99E-07 4.03E-07 4.00E-07 3.99E-07 3.85E-07 4.23E-07 3.87E-07 3.92E-07 3.37E-07 3.54E-07 4.27E-07 6.62E-09 4.45E-07 4.08E-07 4.27E-07 7.56E-09 4.48E-07 4.06E-07 3.96E-07 6.28E-09 4.14E-07 3.79E-07 3.68E-07 3.88E-07 4.25E-07 4.25E-07 3.97E-07 1.44E-08 1.43E-08 1.49E-08 1.53E-08 1.53E-08 4.08E-07 4.27E-07 4.66E-07 4.67E-07 4.39E-07 3.29E-07 3.48E-07 3.84E-07 3.83E-07 3.55E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07 PASS PASS PASS PASS PASS 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 72 50 4.16E-07 4.26E-07 4.29E-07 4.33E-07 4.30E-07 4.28E-07 4.12E-07 4.50E-07 4.17E-07 4.19E-07 3.40E-07 3.58E-07 24 Hr Anneal 60 4.15E-07 4.24E-07 4.31E-07 4.32E-07 4.33E-07 4.27E-07 4.14E-07 4.51E-07 4.15E-07 4.18E-07 3.38E-07 3.60E-07 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.31. Plot of -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 73 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.31. Raw data for -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V Device 0 10 557 3.47E-07 3.61E-07 563 3.37E-07 3.63E-07 564 3.50E-07 3.79E-07 567 3.40E-07 3.67E-07 569 3.42E-07 3.72E-07 570 3.37E-07 3.45E-07 571 3.36E-07 3.39E-07 572 3.46E-07 3.53E-07 573 3.38E-07 3.35E-07 574 3.37E-07 3.35E-07 584 3.29E-07 3.28E-07 585 3.43E-07 3.44E-07 Biased Statistics Average Biased 3.43E-07 3.68E-07 Std Dev Biased 5.31E-09 7.24E-09 Ps90%/90% (+KTL) Biased 3.58E-07 3.88E-07 Ps90%/90% (-KTL) Biased 3.29E-07 3.48E-07 Un-Biased Statistics Average Un-Biased 3.39E-07 3.42E-07 Std Dev Un-Biased 4.08E-09 7.80E-09 Ps90%/90% (+KTL) Un-Biased 3.50E-07 3.63E-07 Ps90%/90% (-KTL) Un-Biased 3.28E-07 3.20E-07 Specification MIN -7.15E-07 -7.65E-07 Status PASS PASS Specification MAX 7.15E-07 7.65E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.85E-07 4.01E-07 3.84E-07 3.99E-07 4.03E-07 4.15E-07 3.90E-07 4.02E-07 3.95E-07 4.07E-07 3.60E-07 3.77E-07 3.53E-07 3.72E-07 3.71E-07 3.91E-07 3.53E-07 3.71E-07 3.50E-07 3.69E-07 3.29E-07 3.28E-07 3.41E-07 3.46E-07 3.92E-07 8.04E-09 4.14E-07 3.69E-07 4.05E-07 6.21E-09 4.22E-07 3.88E-07 168 Hr Anneal 70 4.05E-07 3.98E-07 4.10E-07 3.98E-07 4.04E-07 3.85E-07 3.82E-07 4.04E-07 3.81E-07 3.79E-07 3.30E-07 3.44E-07 4.37E-07 5.93E-09 4.53E-07 4.21E-07 4.34E-07 6.84E-09 4.53E-07 4.15E-07 4.03E-07 5.02E-09 4.17E-07 3.89E-07 3.58E-07 3.76E-07 4.14E-07 4.11E-07 3.86E-07 8.57E-09 8.78E-09 9.67E-09 9.54E-09 1.00E-08 3.81E-07 4.00E-07 4.40E-07 4.37E-07 4.13E-07 3.34E-07 3.52E-07 3.87E-07 3.85E-07 3.59E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07 PASS PASS PASS PASS PASS 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 74 50 4.39E-07 4.30E-07 4.44E-07 4.32E-07 4.39E-07 4.15E-07 4.07E-07 4.30E-07 4.09E-07 4.07E-07 3.30E-07 3.49E-07 24 Hr Anneal 60 4.36E-07 4.28E-07 4.43E-07 4.27E-07 4.38E-07 4.12E-07 4.07E-07 4.27E-07 4.06E-07 4.03E-07 3.31E-07 3.52E-07 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.32. Plot of -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 75 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.32. Raw data for -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V Device 0 10 557 3.31E-07 3.41E-07 563 3.41E-07 3.65E-07 564 3.42E-07 3.69E-07 567 3.36E-07 3.59E-07 569 3.37E-07 3.62E-07 570 3.37E-07 3.44E-07 571 3.33E-07 3.40E-07 572 3.34E-07 3.41E-07 573 3.23E-07 3.27E-07 574 3.39E-07 3.38E-07 584 3.37E-07 3.40E-07 585 3.36E-07 3.40E-07 Biased Statistics Average Biased 3.37E-07 3.59E-07 Std Dev Biased 4.31E-09 1.08E-08 Ps90%/90% (+KTL) Biased 3.49E-07 3.89E-07 Ps90%/90% (-KTL) Biased 3.26E-07 3.30E-07 Un-Biased Statistics Average Un-Biased 3.33E-07 3.38E-07 Std Dev Un-Biased 6.10E-09 6.58E-09 Ps90%/90% (+KTL) Un-Biased 3.50E-07 3.56E-07 Ps90%/90% (-KTL) Un-Biased 3.16E-07 3.20E-07 Specification MIN -7.15E-07 -7.65E-07 Status PASS PASS Specification MAX 7.15E-07 7.65E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.65E-07 3.83E-07 3.85E-07 4.00E-07 3.93E-07 4.04E-07 3.80E-07 3.92E-07 3.86E-07 3.98E-07 3.61E-07 3.79E-07 3.49E-07 3.68E-07 3.52E-07 3.70E-07 3.36E-07 3.54E-07 3.54E-07 3.74E-07 3.41E-07 3.39E-07 3.34E-07 3.39E-07 3.82E-07 1.03E-08 4.10E-07 3.54E-07 3.95E-07 8.40E-09 4.18E-07 3.72E-07 168 Hr Anneal 70 3.88E-07 3.98E-07 4.02E-07 3.90E-07 3.95E-07 3.88E-07 3.77E-07 3.81E-07 3.64E-07 3.86E-07 3.39E-07 3.38E-07 4.26E-07 5.43E-09 4.41E-07 4.11E-07 4.24E-07 6.97E-09 4.43E-07 4.05E-07 3.95E-07 5.91E-09 4.11E-07 3.78E-07 3.50E-07 3.69E-07 4.06E-07 4.04E-07 3.79E-07 9.05E-09 9.43E-09 1.02E-08 1.10E-08 9.33E-09 3.75E-07 3.95E-07 4.34E-07 4.34E-07 4.05E-07 3.26E-07 3.43E-07 3.78E-07 3.74E-07 3.54E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07 PASS PASS PASS PASS PASS 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 76 50 4.21E-07 4.27E-07 4.34E-07 4.21E-07 4.27E-07 4.13E-07 4.05E-07 4.08E-07 3.89E-07 4.14E-07 3.40E-07 3.43E-07 24 Hr Anneal 60 4.17E-07 4.26E-07 4.34E-07 4.17E-07 4.25E-07 4.13E-07 4.03E-07 4.06E-07 3.85E-07 4.12E-07 3.42E-07 3.44E-07 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.33. Plot of -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 77 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.33. Raw data for -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V Device 0 10 557 3.37E-07 3.47E-07 563 3.47E-07 3.70E-07 564 3.59E-07 3.88E-07 567 3.34E-07 3.57E-07 569 3.39E-07 3.65E-07 570 3.39E-07 3.40E-07 571 3.30E-07 3.37E-07 572 3.44E-07 3.51E-07 573 3.21E-07 3.25E-07 574 3.50E-07 3.55E-07 584 3.35E-07 3.37E-07 585 3.46E-07 3.47E-07 Biased Statistics Average Biased 3.43E-07 3.65E-07 Std Dev Biased 1.01E-08 1.52E-08 Ps90%/90% (+KTL) Biased 3.71E-07 4.07E-07 Ps90%/90% (-KTL) Biased 3.16E-07 3.24E-07 Un-Biased Statistics Average Un-Biased 3.37E-07 3.42E-07 Std Dev Un-Biased 1.14E-08 1.22E-08 Ps90%/90% (+KTL) Un-Biased 3.68E-07 3.75E-07 Ps90%/90% (-KTL) Un-Biased 3.05E-07 3.08E-07 Specification MIN -7.15E-07 -7.65E-07 Status PASS PASS Specification MAX 7.15E-07 7.65E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.71E-07 3.88E-07 3.89E-07 4.02E-07 4.11E-07 4.23E-07 3.79E-07 3.90E-07 3.88E-07 4.01E-07 3.55E-07 3.70E-07 3.45E-07 3.65E-07 3.69E-07 3.87E-07 3.41E-07 3.52E-07 3.72E-07 3.92E-07 3.37E-07 3.36E-07 3.44E-07 3.48E-07 3.87E-07 1.49E-08 4.28E-07 3.47E-07 4.01E-07 1.39E-08 4.39E-07 3.63E-07 168 Hr Anneal 70 3.92E-07 4.02E-07 4.17E-07 3.88E-07 3.97E-07 3.81E-07 3.75E-07 3.98E-07 3.64E-07 4.03E-07 3.36E-07 3.47E-07 4.32E-07 1.32E-08 4.68E-07 3.96E-07 4.30E-07 1.36E-08 4.67E-07 3.92E-07 3.99E-07 1.12E-08 4.30E-07 3.68E-07 3.56E-07 3.73E-07 4.12E-07 4.09E-07 3.84E-07 1.37E-08 1.63E-08 1.84E-08 1.80E-08 1.60E-08 3.94E-07 4.18E-07 4.62E-07 4.59E-07 4.28E-07 3.19E-07 3.29E-07 3.62E-07 3.60E-07 3.40E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07 PASS PASS PASS PASS PASS 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 78 50 4.26E-07 4.32E-07 4.54E-07 4.19E-07 4.30E-07 4.09E-07 4.02E-07 4.26E-07 3.88E-07 4.34E-07 3.38E-07 3.51E-07 24 Hr Anneal 60 4.22E-07 4.31E-07 4.52E-07 4.16E-07 4.29E-07 4.08E-07 4.00E-07 4.23E-07 3.85E-07 4.30E-07 3.37E-07 3.53E-07 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.34. Plot of -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 79 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.34. Raw data for -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V Device 0 10 557 3.38E-07 3.47E-07 563 3.39E-07 3.64E-07 564 3.42E-07 3.70E-07 567 3.44E-07 3.71E-07 569 3.45E-07 3.75E-07 570 3.40E-07 3.47E-07 571 3.40E-07 3.42E-07 572 3.41E-07 3.50E-07 573 3.41E-07 3.37E-07 574 3.39E-07 3.37E-07 584 3.32E-07 3.31E-07 585 3.45E-07 3.48E-07 Biased Statistics Average Biased 3.41E-07 3.65E-07 Std Dev Biased 3.02E-09 1.10E-08 Ps90%/90% (+KTL) Biased 3.50E-07 3.96E-07 Ps90%/90% (-KTL) Biased 3.33E-07 3.35E-07 Un-Biased Statistics Average Un-Biased 3.40E-07 3.43E-07 Std Dev Un-Biased 8.25E-10 5.76E-09 Ps90%/90% (+KTL) Un-Biased 3.42E-07 3.58E-07 Ps90%/90% (-KTL) Un-Biased 3.38E-07 3.27E-07 Specification MIN -7.15E-07 -7.65E-07 Status PASS PASS Specification MAX 7.15E-07 7.65E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.69E-07 3.86E-07 3.85E-07 3.99E-07 3.92E-07 4.04E-07 3.94E-07 4.08E-07 3.99E-07 4.14E-07 3.61E-07 3.78E-07 3.56E-07 3.74E-07 3.67E-07 3.86E-07 3.54E-07 3.75E-07 3.53E-07 3.71E-07 3.31E-07 3.31E-07 3.44E-07 3.50E-07 3.88E-07 1.18E-08 4.20E-07 3.56E-07 4.02E-07 1.07E-08 4.31E-07 3.73E-07 168 Hr Anneal 70 3.90E-07 3.98E-07 4.02E-07 4.04E-07 4.09E-07 3.85E-07 3.85E-07 3.98E-07 3.83E-07 3.81E-07 3.33E-07 3.48E-07 4.33E-07 8.35E-09 4.56E-07 4.10E-07 4.31E-07 7.70E-09 4.52E-07 4.10E-07 4.00E-07 7.13E-09 4.20E-07 3.81E-07 3.58E-07 3.77E-07 4.14E-07 4.12E-07 3.86E-07 5.84E-09 5.64E-09 4.81E-09 5.96E-09 6.61E-09 3.74E-07 3.92E-07 4.27E-07 4.28E-07 4.05E-07 3.42E-07 3.61E-07 4.00E-07 3.95E-07 3.68E-07 -8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07 PASS PASS PASS PASS PASS 8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 80 50 4.21E-07 4.30E-07 4.34E-07 4.37E-07 4.43E-07 4.13E-07 4.11E-07 4.22E-07 4.11E-07 4.10E-07 3.33E-07 3.51E-07 24 Hr Anneal 60 4.20E-07 4.28E-07 4.34E-07 4.33E-07 4.41E-07 4.11E-07 4.11E-07 4.22E-07 4.08E-07 4.07E-07 3.34E-07 3.54E-07 Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.35. Plot of Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 81 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.35. Raw data for Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.06E-04 -1.55E-04 -4.30E-07 1.41E-05 -1.79E-04 9.51E-05 -2.68E-04 1.63E-04 6.93E-06 -3.11E-05 -4.62E-04 1.27E-04 Total Dose (krad(Si)) 20 30 -2.16E-04 -2.19E-04 -1.64E-04 -1.65E-04 -7.80E-06 -5.50E-06 1.14E-06 2.46E-06 -1.85E-04 -1.85E-04 8.14E-05 7.84E-05 -2.79E-04 -2.80E-04 1.47E-04 1.47E-04 4.10E-07 -3.45E-06 -3.88E-05 -4.14E-05 -4.63E-04 -4.63E-04 1.27E-04 1.22E-04 10 -2.15E-04 -1.61E-04 -7.68E-06 4.52E-06 -1.88E-04 8.35E-05 -2.76E-04 1.50E-04 1.98E-06 -4.02E-05 -4.62E-04 1.21E-04 50 -2.27E-04 -1.70E-04 -1.33E-05 1.75E-06 -1.88E-04 7.09E-05 -2.84E-04 1.44E-04 -9.48E-06 -4.87E-05 -4.65E-04 1.23E-04 24 Hr Anneal 60 -2.24E-04 -1.70E-04 -1.55E-05 1.39E-06 -1.90E-04 6.78E-05 -2.85E-04 1.43E-04 -1.08E-05 -5.10E-05 -4.66E-04 1.18E-04 168 Hr Anneal 70 -2.20E-04 -1.86E-04 -1.25E-05 -2.36E-06 -1.89E-04 7.23E-05 -2.90E-04 1.37E-04 -2.10E-05 -5.07E-05 -4.65E-04 1.21E-04 -1.05E-04 -1.13E-04 -1.14E-04 -1.14E-04 -1.19E-04 -1.20E-04 -1.22E-04 1.04E-04 1.04E-04 1.03E-04 1.05E-04 1.06E-04 1.05E-04 1.05E-04 1.80E-04 1.72E-04 1.68E-04 1.73E-04 1.71E-04 1.67E-04 1.67E-04 -3.91E-04 -3.99E-04 -3.97E-04 -4.02E-04 -4.09E-04 -4.06E-04 -4.11E-04 -6.93E-06 1.65E-04 4.44E-04 -4.58E-04 -8.00E-04 PASS 8.00E-04 PASS -1.61E-05 1.63E-04 4.31E-04 -4.63E-04 -9.50E-04 PASS 9.50E-04 PASS -1.77E-05 1.63E-04 4.28E-04 -4.64E-04 -9.50E-04 PASS 9.50E-04 PASS -1.99E-05 1.63E-04 4.26E-04 -4.66E-04 -9.50E-04 PASS 9.50E-04 PASS -2.56E-05 1.62E-04 4.20E-04 -4.71E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 82 -2.72E-05 1.62E-04 4.17E-04 -4.72E-04 -9.50E-04 PASS 9.50E-04 PASS -3.05E-05 1.63E-04 4.17E-04 -4.78E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.36. Plot of Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 83 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.36. Raw data for Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.51E-04 -2.25E-04 -2.45E-05 -1.65E-04 -6.25E-05 -6.85E-05 4.98E-05 1.09E-05 -1.95E-04 -3.68E-05 -3.34E-04 -3.10E-07 Total Dose (krad(Si)) 20 30 -2.59E-04 -2.57E-04 -2.33E-04 -2.35E-04 -2.91E-05 -2.89E-05 -1.69E-04 -1.68E-04 -6.62E-05 -6.59E-05 -7.75E-05 -7.82E-05 4.57E-05 4.80E-05 -5.02E-06 -7.68E-06 -1.99E-04 -2.01E-04 -4.29E-05 -4.50E-05 -3.37E-04 -3.35E-04 -3.45E-06 -5.87E-06 10 -2.58E-04 -2.32E-04 -3.04E-05 -1.67E-04 -6.35E-05 -7.55E-05 4.79E-05 -4.17E-06 -2.01E-04 -4.33E-05 -3.35E-04 -4.42E-06 50 -2.61E-04 -2.37E-04 -3.68E-05 -1.75E-04 -6.55E-05 -8.07E-05 4.61E-05 -1.11E-05 -1.98E-04 -4.97E-05 -3.35E-04 5.40E-07 24 Hr Anneal 60 -2.62E-04 -2.33E-04 -3.41E-05 -1.77E-04 -6.45E-05 -8.07E-05 4.57E-05 -1.08E-05 -2.01E-04 -4.88E-05 -3.33E-04 -6.22E-06 168 Hr Anneal 70 -2.66E-04 -2.28E-04 -2.72E-05 -1.57E-04 -7.05E-05 -7.93E-05 3.24E-05 -1.41E-05 -2.07E-04 -4.87E-05 -3.35E-04 -3.45E-06 -1.46E-04 -1.50E-04 -1.51E-04 -1.51E-04 -1.55E-04 -1.54E-04 -1.50E-04 9.92E-05 1.01E-04 1.01E-04 1.01E-04 1.00E-04 1.01E-04 1.01E-04 1.27E-04 1.26E-04 1.26E-04 1.26E-04 1.20E-04 1.23E-04 1.28E-04 -4.18E-04 -4.26E-04 -4.28E-04 -4.28E-04 -4.30E-04 -4.31E-04 -4.27E-04 -4.80E-05 9.40E-05 2.10E-04 -3.06E-04 -8.00E-04 PASS 8.00E-04 PASS -5.52E-05 9.35E-05 2.01E-04 -3.11E-04 -9.50E-04 PASS 9.50E-04 PASS -5.58E-05 9.23E-05 1.97E-04 -3.09E-04 -9.50E-04 PASS 9.50E-04 PASS -5.68E-05 9.34E-05 1.99E-04 -3.13E-04 -9.50E-04 PASS 9.50E-04 PASS -5.86E-05 9.11E-05 1.91E-04 -3.08E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 84 -5.91E-05 9.21E-05 1.93E-04 -3.12E-04 -9.50E-04 PASS 9.50E-04 PASS -6.34E-05 9.06E-05 1.85E-04 -3.12E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.37. Plot of Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 85 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.37. Raw data for Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.94E-04 -7.27E-05 -5.73E-05 -3.29E-05 -1.77E-04 -1.82E-04 -1.55E-04 2.30E-04 5.52E-05 1.08E-04 3.61E-04 3.75E-05 Total Dose (krad(Si)) 20 30 2.80E-04 2.73E-04 -8.07E-05 -8.56E-05 -6.80E-05 -6.80E-05 -4.08E-05 -4.32E-05 -1.85E-04 -1.89E-04 -1.89E-04 -1.92E-04 -1.66E-04 -1.68E-04 2.16E-04 2.10E-04 5.09E-05 4.98E-05 1.00E-04 9.46E-05 3.63E-04 3.63E-04 3.48E-05 3.22E-05 10 2.83E-04 -7.93E-05 -6.14E-05 -3.40E-05 -1.80E-04 -1.88E-04 -1.64E-04 2.20E-04 5.09E-05 1.02E-04 3.64E-04 3.63E-05 50 2.67E-04 -8.43E-05 -7.34E-05 -4.50E-05 -1.91E-04 -1.96E-04 -1.77E-04 2.05E-04 4.28E-05 8.89E-05 3.62E-04 3.74E-05 24 Hr Anneal 60 2.65E-04 -8.38E-05 -7.83E-05 -4.63E-05 -1.96E-04 -1.98E-04 -1.77E-04 2.02E-04 4.34E-05 8.86E-05 3.59E-04 2.90E-05 168 Hr Anneal 70 2.61E-04 -7.98E-05 -8.24E-05 -5.07E-05 -1.88E-04 -1.93E-04 -1.64E-04 1.91E-04 3.98E-05 8.35E-05 3.60E-04 3.28E-05 -9.18E-06 -1.44E-05 -1.90E-05 -2.26E-05 -2.53E-05 -2.79E-05 -2.80E-05 1.78E-04 1.75E-04 1.76E-04 1.75E-04 1.72E-04 1.73E-04 1.69E-04 4.79E-04 4.66E-04 4.63E-04 4.56E-04 4.47E-04 4.48E-04 4.37E-04 -4.97E-04 -4.95E-04 -5.01E-04 -5.01E-04 -4.98E-04 -5.04E-04 -4.93E-04 1.11E-05 1.76E-04 4.94E-04 -4.72E-04 -8.00E-04 PASS 8.00E-04 PASS 4.25E-06 1.76E-04 4.86E-04 -4.77E-04 -9.50E-04 PASS 9.50E-04 PASS 2.42E-06 1.75E-04 4.83E-04 -4.78E-04 -9.50E-04 PASS 9.50E-04 PASS -1.23E-06 1.74E-04 4.75E-04 -4.77E-04 -9.50E-04 PASS 9.50E-04 PASS -7.14E-06 1.74E-04 4.70E-04 -4.85E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 86 -8.05E-06 1.74E-04 4.68E-04 -4.84E-04 -9.50E-04 PASS 9.50E-04 PASS -8.49E-06 1.65E-04 4.43E-04 -4.60E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.38. Plot of Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 87 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.38. Raw data for Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -6.17E-05 2.39E-05 1.26E-04 1.35E-04 -2.83E-04 8.81E-05 1.60E-04 -1.18E-05 6.08E-05 -2.46E-04 9.33E-05 -1.80E-04 Total Dose (krad(Si)) 20 30 -7.35E-05 -7.48E-05 1.35E-05 1.49E-05 1.22E-04 1.23E-04 1.30E-04 1.31E-04 -2.87E-04 -2.92E-04 7.84E-05 8.17E-05 1.51E-04 1.51E-04 -2.56E-05 -2.51E-05 5.79E-05 6.04E-05 -2.52E-04 -2.51E-04 9.25E-05 9.27E-05 -1.80E-04 -1.80E-04 10 -7.15E-05 1.48E-05 1.22E-04 1.31E-04 -2.86E-04 7.85E-05 1.52E-04 -2.28E-05 5.47E-05 -2.53E-04 9.27E-05 -1.82E-04 50 -8.08E-05 8.27E-06 1.17E-04 1.26E-04 -2.88E-04 8.59E-05 1.48E-04 -2.99E-05 6.10E-05 -2.53E-04 8.93E-05 -1.79E-04 24 Hr Anneal 60 -8.11E-05 5.85E-06 1.13E-04 1.25E-04 -2.89E-04 8.18E-05 1.45E-04 -3.28E-05 5.64E-05 -2.54E-04 8.64E-05 -1.83E-04 168 Hr Anneal 70 -7.70E-05 1.59E-05 1.15E-04 1.24E-04 -2.85E-04 7.66E-05 1.47E-04 -2.60E-05 4.67E-05 -2.62E-04 8.87E-05 -1.82E-04 -1.18E-05 -1.80E-05 -1.89E-05 -1.94E-05 -2.36E-05 -2.53E-05 -2.15E-05 1.72E-04 1.71E-04 1.72E-04 1.74E-04 1.71E-04 1.70E-04 1.69E-04 4.59E-04 4.52E-04 4.52E-04 4.58E-04 4.44E-04 4.40E-04 4.41E-04 -4.82E-04 -4.88E-04 -4.90E-04 -4.97E-04 -4.92E-04 -4.91E-04 -4.84E-04 1.00E-05 1.56E-04 4.38E-04 -4.18E-04 -8.00E-04 PASS 8.00E-04 PASS 1.84E-06 1.55E-04 4.28E-04 -4.24E-04 -9.50E-04 PASS 9.50E-04 PASS 1.93E-06 1.55E-04 4.28E-04 -4.24E-04 -9.50E-04 PASS 9.50E-04 PASS 3.55E-06 1.55E-04 4.30E-04 -4.22E-04 -9.50E-04 PASS 9.50E-04 PASS 2.42E-06 1.56E-04 4.31E-04 -4.27E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 88 -6.18E-07 1.55E-04 4.25E-04 -4.26E-04 -9.50E-04 PASS 9.50E-04 PASS -3.62E-06 1.57E-04 4.28E-04 -4.35E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.39. Plot of Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 89 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.39. Raw data for Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.35E-09 -4.26E-09 -3.30E-10 5.37E-09 1.69E-09 -1.30E-10 -5.52E-09 2.33E-09 -2.36E-09 5.13E-09 -8.69E-09 1.49E-09 10 2.17E-09 -4.85E-09 -5.20E-10 5.02E-09 5.00E-10 -4.00E-10 -5.73E-09 2.22E-09 -2.56E-09 4.94E-09 -9.31E-09 -2.20E-10 Total Dose 20 1.32E-09 -4.90E-09 -1.47E-09 4.50E-09 -1.80E-10 -6.00E-11 -6.40E-09 2.25E-09 -2.74E-09 5.10E-09 -9.69E-09 -2.90E-10 (krad(Si)) 30 9.70E-10 -5.62E-09 -2.02E-09 4.61E-09 -1.03E-09 -1.10E-10 -6.67E-09 2.25E-09 -2.85E-09 4.72E-09 -1.00E-08 -2.50E-10 50 -3.80E-10 -6.94E-09 -3.91E-09 3.96E-09 -2.61E-09 3.40E-10 -6.72E-09 2.42E-09 -2.92E-09 5.83E-09 -1.02E-08 -3.80E-10 24 Hr Anneal 60 -1.27E-09 -7.63E-09 -4.57E-09 3.27E-09 -2.86E-09 1.10E-10 -7.75E-09 1.24E-09 -3.84E-09 4.37E-09 -1.04E-08 -4.50E-10 168 Hr Anneal 70 2.20E-10 -6.07E-09 -3.03E-09 3.14E-09 -1.39E-09 -2.40E-10 -6.45E-09 1.49E-09 -3.12E-09 4.91E-09 -1.06E-08 -5.90E-10 9.64E-10 4.64E-10 -1.46E-10 -6.18E-10 -1.98E-09 -2.61E-09 -1.43E-09 3.56E-09 3.64E-09 3.47E-09 3.78E-09 4.08E-09 4.05E-09 3.45E-09 1.07E-08 1.04E-08 9.36E-09 9.73E-09 9.21E-09 8.48E-09 8.04E-09 -8.81E-09 -9.51E-09 -9.65E-09 -1.10E-08 -1.32E-08 -1.37E-08 -1.09E-08 -1.10E-10 4.12E-09 1.12E-08 -1.14E-08 -7.00E-08 PASS 7.00E-08 PASS -3.06E-10 4.14E-09 1.10E-08 -1.16E-08 -1.00E-07 PASS 1.00E-07 PASS -3.70E-10 4.44E-09 1.18E-08 -1.25E-08 -1.00E-07 PASS 1.00E-07 PASS -5.32E-10 4.43E-09 1.16E-08 -1.27E-08 -1.00E-07 PASS 1.00E-07 PASS -2.10E-10 4.83E-09 1.30E-08 -1.35E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 90 -1.17E-09 4.71E-09 1.17E-08 -1.41E-08 -1.00E-07 PASS 1.00E-07 PASS -6.82E-10 4.34E-09 1.12E-08 -1.26E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.40. Plot of Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 91 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.40. Raw data for Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 1.91E-09 -2.90E-09 -2.91E-09 -1.90E-10 2.12E-09 -2.44E-09 -1.22E-09 1.59E-09 2.40E-10 -2.16E-09 2.42E-09 1.39E-09 10 1.89E-09 -3.24E-09 -3.89E-09 -7.20E-10 2.55E-09 -2.25E-09 -1.56E-09 1.70E-09 8.00E-11 -2.13E-09 2.12E-09 -1.40E-10 Total Dose 20 1.69E-09 -3.80E-09 -4.56E-09 -4.70E-10 2.78E-09 -2.58E-09 -1.45E-09 1.80E-09 -2.50E-10 -2.35E-09 1.64E-09 -1.90E-10 (krad(Si)) 30 1.32E-09 -4.47E-09 -5.11E-09 -1.15E-09 2.69E-09 -2.57E-09 -8.20E-10 2.02E-09 -3.50E-10 -2.55E-09 1.39E-09 -2.30E-10 50 -5.60E-10 -5.04E-09 -5.63E-09 -1.79E-09 2.09E-09 -2.79E-09 -1.90E-09 2.58E-09 -3.60E-10 -2.16E-09 1.27E-09 -1.20E-10 24 Hr Anneal 60 -1.14E-09 -5.66E-09 -6.19E-09 -2.61E-09 1.57E-09 -3.43E-09 -3.00E-09 1.47E-09 -9.70E-10 -3.05E-09 1.07E-09 -1.50E-10 168 Hr Anneal 70 -1.40E-10 -4.43E-09 -4.73E-09 -2.19E-09 9.40E-10 -3.03E-09 -2.56E-09 2.02E-09 -2.90E-10 -2.56E-09 9.30E-10 -2.50E-10 -3.94E-10 -6.82E-10 -8.72E-10 -1.34E-09 -2.19E-09 -2.81E-09 -2.11E-09 2.46E-09 2.91E-09 3.25E-09 3.44E-09 3.21E-09 3.22E-09 2.52E-09 6.36E-09 7.30E-09 8.04E-09 8.09E-09 6.60E-09 6.03E-09 4.80E-09 -7.15E-09 -8.66E-09 -9.78E-09 -1.08E-08 -1.10E-08 -1.16E-08 -9.02E-09 -7.98E-10 1.70E-09 3.85E-09 -5.45E-09 -7.00E-08 PASS 7.00E-08 PASS -8.32E-10 1.69E-09 3.81E-09 -5.47E-09 -1.00E-07 PASS 1.00E-07 PASS -9.66E-10 1.80E-09 3.96E-09 -5.89E-09 -1.00E-07 PASS 1.00E-07 PASS -8.54E-10 1.89E-09 4.34E-09 -6.05E-09 -1.00E-07 PASS 1.00E-07 PASS -9.26E-10 2.15E-09 4.98E-09 -6.83E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 92 -1.80E-09 2.06E-09 3.86E-09 -7.46E-09 -1.00E-07 PASS 1.00E-07 PASS -1.28E-09 2.13E-09 4.57E-09 -7.13E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.41. Plot of Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 93 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.41. Raw data for Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.82E-09 -1.19E-09 -2.38E-09 5.34E-09 -5.30E-09 1.73E-09 -3.95E-09 -2.10E-10 2.70E-09 -5.02E-09 -1.00E-10 -6.94E-09 10 1.15E-09 2.61E-09 2.10E-10 7.81E-09 -2.59E-09 4.79E-09 -7.40E-10 2.98E-09 5.80E-09 -1.86E-09 3.16E-09 -4.92E-09 Total Dose 20 -7.00E-11 8.00E-10 -1.52E-09 6.34E-09 -4.17E-09 3.90E-09 -1.71E-09 2.11E-09 4.82E-09 -3.08E-09 1.94E-09 -5.85E-09 (krad(Si)) 30 -1.53E-09 -6.90E-10 -2.40E-09 5.52E-09 -5.70E-09 3.27E-09 -1.74E-09 8.40E-10 4.37E-09 -3.78E-09 1.16E-09 -6.48E-09 50 -2.00E-09 -9.40E-10 -2.77E-09 5.17E-09 -6.68E-09 3.27E-09 -2.46E-09 1.61E-09 4.50E-09 -3.11E-09 1.35E-09 -6.19E-09 24 Hr Anneal 60 -2.66E-09 -2.08E-09 -3.19E-09 5.11E-09 -7.18E-09 2.49E-09 -3.33E-09 3.00E-10 3.69E-09 -3.77E-09 1.20E-09 -6.36E-09 168 Hr Anneal 70 -1.54E-09 -1.65E-09 -3.26E-09 5.62E-09 -5.31E-09 2.73E-09 -1.95E-09 1.25E-09 4.38E-09 -2.98E-09 9.30E-10 -6.50E-09 -1.07E-09 1.84E-09 2.76E-10 -9.60E-10 -1.44E-09 -2.00E-09 -1.23E-09 3.91E-09 3.84E-09 3.88E-09 4.09E-09 4.29E-09 4.45E-09 4.12E-09 9.66E-09 1.24E-08 1.09E-08 1.03E-08 1.03E-08 1.02E-08 1.01E-08 -1.18E-08 -8.69E-09 -1.04E-08 -1.22E-08 -1.32E-08 -1.42E-08 -1.25E-08 -9.50E-10 3.41E-09 8.41E-09 -1.03E-08 -7.00E-08 PASS 7.00E-08 PASS 2.19E-09 3.37E-09 1.14E-08 -7.04E-09 -1.00E-07 PASS 1.00E-07 PASS 1.21E-09 3.46E-09 1.07E-08 -8.29E-09 -1.00E-07 PASS 1.00E-07 PASS 5.92E-10 3.39E-09 9.90E-09 -8.71E-09 -1.00E-07 PASS 1.00E-07 PASS 7.62E-10 3.40E-09 1.01E-08 -8.57E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 94 -1.24E-10 3.36E-09 9.09E-09 -9.33E-09 -1.00E-07 PASS 1.00E-07 PASS 6.86E-10 3.10E-09 9.20E-09 -7.82E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.42. Plot of Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 95 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.42. Raw data for Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.13E-09 -6.80E-10 1.42E-08 7.26E-09 -2.67E-09 4.25E-09 7.99E-09 1.01E-09 1.00E-08 2.66E-09 3.23E-09 -1.52E-09 10 -2.12E-09 -5.11E-09 9.81E-09 2.97E-09 -5.38E-09 7.40E-10 4.41E-09 -2.59E-09 6.64E-09 -5.10E-10 -2.00E-11 -6.16E-09 Total Dose 20 -3.68E-09 -7.10E-09 6.91E-09 6.30E-10 -6.95E-09 -9.60E-10 3.08E-09 -3.82E-09 5.70E-09 -1.93E-09 -1.49E-09 -7.27E-09 (krad(Si)) 30 -4.90E-09 -7.68E-09 5.61E-09 -4.00E-10 -8.32E-09 -1.07E-09 2.67E-09 -4.75E-09 5.32E-09 -2.06E-09 -2.22E-09 -7.69E-09 50 -5.82E-09 -9.01E-09 4.22E-09 -2.09E-09 -8.61E-09 -1.16E-09 2.08E-09 -4.36E-09 4.70E-09 -3.32E-09 -2.74E-09 -8.36E-09 24 Hr Anneal 60 -6.39E-09 -1.06E-08 3.60E-09 -1.89E-09 -9.16E-09 -2.20E-09 1.53E-09 -5.45E-09 3.64E-09 -3.80E-09 -2.80E-09 -8.54E-09 168 Hr Anneal 70 -5.48E-09 -9.10E-09 5.05E-09 -1.24E-09 -9.57E-09 -1.38E-09 2.33E-09 -4.94E-09 5.01E-09 -3.27E-09 -3.09E-09 -8.45E-09 4.06E-09 3.40E-11 -2.04E-09 -3.14E-09 -4.26E-09 -4.88E-09 -4.07E-09 6.81E-09 6.41E-09 5.91E-09 5.80E-09 5.49E-09 5.78E-09 6.10E-09 2.27E-08 1.76E-08 1.42E-08 1.28E-08 1.08E-08 1.10E-08 1.27E-08 -1.46E-08 -1.76E-08 -1.82E-08 -1.90E-08 -1.93E-08 -2.07E-08 -2.08E-08 5.19E-09 3.75E-09 1.55E-08 -5.08E-09 -7.00E-08 PASS 7.00E-08 PASS 1.74E-09 3.74E-09 1.20E-08 -8.52E-09 -1.00E-07 PASS 1.00E-07 PASS 4.14E-10 3.88E-09 1.11E-08 -1.02E-08 -1.00E-07 PASS 1.00E-07 PASS 2.20E-11 3.98E-09 1.09E-08 -1.09E-08 -1.00E-07 PASS 1.00E-07 PASS -4.12E-10 3.77E-09 9.93E-09 -1.08E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 96 -1.26E-09 3.76E-09 9.07E-09 -1.16E-08 -1.00E-07 PASS 1.00E-07 PASS -4.50E-10 4.08E-09 1.07E-08 -1.16E-08 -1.00E-07 PASS 1.00E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.43. Plot of +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 97 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.43. Raw data for +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.48E-07 -3.67E-07 -3.73E-07 -3.84E-07 -3.72E-07 -3.81E-07 -3.64E-07 -3.62E-07 -3.68E-07 -3.66E-07 -3.48E-07 -3.58E-07 10 -3.58E-07 -3.80E-07 -3.86E-07 -3.98E-07 -3.86E-07 -3.82E-07 -3.69E-07 -3.67E-07 -3.72E-07 -3.69E-07 -3.45E-07 -3.59E-07 Total Dose (krad(Si)) 20 30 -3.63E-07 -3.71E-07 -3.87E-07 -3.92E-07 -3.97E-07 -4.01E-07 -4.09E-07 -4.11E-07 -3.98E-07 -4.03E-07 -3.91E-07 -3.97E-07 -3.77E-07 -3.85E-07 -3.72E-07 -3.79E-07 -3.78E-07 -3.85E-07 -3.77E-07 -3.84E-07 -3.46E-07 -3.48E-07 -3.55E-07 -3.58E-07 50 -3.88E-07 -4.09E-07 -4.18E-07 -4.25E-07 -4.16E-07 -4.13E-07 -4.02E-07 -4.00E-07 -4.02E-07 -4.00E-07 -3.51E-07 -3.55E-07 24 Hr Anneal 60 -3.87E-07 -4.10E-07 -4.18E-07 -4.27E-07 -4.15E-07 -4.13E-07 -4.03E-07 -3.99E-07 -4.02E-07 -4.02E-07 -3.52E-07 -3.59E-07 168 Hr Anneal 70 -3.73E-07 -3.91E-07 -3.99E-07 -4.09E-07 -3.99E-07 -3.98E-07 -3.84E-07 -3.83E-07 -3.86E-07 -3.85E-07 -3.52E-07 -3.61E-07 -3.69E-07 -3.82E-07 -3.91E-07 -3.96E-07 -4.11E-07 -4.12E-07 -3.94E-07 1.34E-08 1.45E-08 1.74E-08 1.54E-08 1.40E-08 1.49E-08 1.35E-08 -3.32E-07 -3.42E-07 -3.43E-07 -3.53E-07 -3.73E-07 -3.71E-07 -3.57E-07 -4.05E-07 -4.21E-07 -4.38E-07 -4.38E-07 -4.50E-07 -4.53E-07 -4.31E-07 -3.68E-07 7.49E-09 -3.48E-07 -3.89E-07 -7.15E-07 PASS 7.15E-07 PASS -3.72E-07 6.09E-09 -3.55E-07 -3.88E-07 -7.65E-07 PASS 7.65E-07 PASS -3.79E-07 7.01E-09 -3.60E-07 -3.98E-07 -8.15E-07 PASS 8.15E-07 PASS -3.86E-07 6.70E-09 -3.68E-07 -4.04E-07 -8.15E-07 PASS 8.15E-07 PASS -4.03E-07 5.62E-09 -3.88E-07 -4.19E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 98 -4.03E-07 5.24E-09 -3.89E-07 -4.18E-07 -8.65E-07 PASS 8.65E-07 PASS -3.87E-07 6.10E-09 -3.70E-07 -4.04E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.44. Plot of +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 99 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.44. Raw data for +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.38E-07 -3.88E-07 -3.69E-07 -3.71E-07 -3.55E-07 -3.70E-07 -3.66E-07 -3.58E-07 -3.55E-07 -3.62E-07 -3.69E-07 -3.66E-07 10 -3.50E-07 -4.00E-07 -3.84E-07 -3.84E-07 -3.69E-07 -3.72E-07 -3.68E-07 -3.61E-07 -3.58E-07 -3.65E-07 -3.64E-07 -3.70E-07 Total Dose (krad(Si)) 20 30 -3.56E-07 -3.64E-07 -4.08E-07 -4.13E-07 -3.95E-07 -3.98E-07 -3.94E-07 -3.98E-07 -3.79E-07 -3.83E-07 -3.81E-07 -3.88E-07 -3.78E-07 -3.84E-07 -3.68E-07 -3.76E-07 -3.66E-07 -3.70E-07 -3.73E-07 -3.79E-07 -3.67E-07 -3.67E-07 -3.66E-07 -3.67E-07 50 -3.81E-07 -4.27E-07 -4.13E-07 -4.11E-07 -3.97E-07 -4.05E-07 -4.02E-07 -3.96E-07 -3.88E-07 -3.99E-07 -3.71E-07 -3.66E-07 24 Hr Anneal 60 -3.82E-07 -4.28E-07 -4.15E-07 -4.14E-07 -3.98E-07 -4.05E-07 -4.01E-07 -3.95E-07 -3.88E-07 -4.00E-07 -3.72E-07 -3.68E-07 168 Hr Anneal 70 -3.65E-07 -4.09E-07 -3.95E-07 -3.96E-07 -3.80E-07 -3.89E-07 -3.85E-07 -3.78E-07 -3.73E-07 -3.81E-07 -3.71E-07 -3.71E-07 -3.64E-07 -3.77E-07 -3.86E-07 -3.91E-07 -4.06E-07 -4.07E-07 -3.89E-07 1.87E-08 1.89E-08 1.97E-08 1.84E-08 1.72E-08 1.78E-08 1.69E-08 -3.13E-07 -3.26E-07 -3.32E-07 -3.41E-07 -3.58E-07 -3.59E-07 -3.43E-07 -4.16E-07 -4.29E-07 -4.40E-07 -4.42E-07 -4.53E-07 -4.56E-07 -4.35E-07 -3.62E-07 5.97E-09 -3.45E-07 -3.78E-07 -7.15E-07 PASS 7.15E-07 PASS -3.65E-07 5.53E-09 -3.50E-07 -3.80E-07 -7.65E-07 PASS 7.65E-07 PASS -3.73E-07 6.61E-09 -3.55E-07 -3.91E-07 -8.15E-07 PASS 8.15E-07 PASS -3.80E-07 6.79E-09 -3.61E-07 -3.98E-07 -8.15E-07 PASS 8.15E-07 PASS -3.98E-07 6.36E-09 -3.80E-07 -4.15E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 100 -3.98E-07 6.42E-09 -3.80E-07 -4.15E-07 -8.65E-07 PASS 8.65E-07 PASS -3.81E-07 6.26E-09 -3.64E-07 -3.98E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.45. Plot of +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 101 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.45. Raw data for +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.46E-07 -3.86E-07 -3.79E-07 -3.73E-07 -3.60E-07 -3.74E-07 -3.70E-07 -3.62E-07 -3.54E-07 -3.68E-07 -3.74E-07 -3.83E-07 10 -3.51E-07 -3.92E-07 -3.88E-07 -3.81E-07 -3.69E-07 -3.72E-07 -3.66E-07 -3.60E-07 -3.51E-07 -3.64E-07 -3.64E-07 -3.79E-07 Total Dose (krad(Si)) 20 30 -3.56E-07 -3.64E-07 -4.02E-07 -4.06E-07 -3.97E-07 -4.02E-07 -3.92E-07 -3.95E-07 -3.79E-07 -3.84E-07 -3.78E-07 -3.88E-07 -3.76E-07 -3.81E-07 -3.68E-07 -3.76E-07 -3.59E-07 -3.65E-07 -3.73E-07 -3.81E-07 -3.66E-07 -3.68E-07 -3.77E-07 -3.77E-07 50 -3.79E-07 -4.19E-07 -4.17E-07 -4.08E-07 -3.98E-07 -4.04E-07 -3.97E-07 -3.92E-07 -3.82E-07 -3.97E-07 -3.71E-07 -3.74E-07 24 Hr Anneal 60 -3.80E-07 -4.22E-07 -4.17E-07 -4.11E-07 -3.98E-07 -4.03E-07 -3.98E-07 -3.93E-07 -3.82E-07 -3.98E-07 -3.72E-07 -3.78E-07 168 Hr Anneal 70 -3.65E-07 -4.04E-07 -3.99E-07 -3.92E-07 -3.81E-07 -3.90E-07 -3.83E-07 -3.77E-07 -3.66E-07 -3.82E-07 -3.72E-07 -3.81E-07 -3.69E-07 -3.76E-07 -3.85E-07 -3.90E-07 -4.04E-07 -4.06E-07 -3.88E-07 1.59E-08 1.67E-08 1.84E-08 1.70E-08 1.63E-08 1.66E-08 1.58E-08 -3.25E-07 -3.30E-07 -3.35E-07 -3.43E-07 -3.60E-07 -3.60E-07 -3.45E-07 -4.12E-07 -4.22E-07 -4.35E-07 -4.37E-07 -4.49E-07 -4.51E-07 -4.31E-07 -3.65E-07 7.65E-09 -3.44E-07 -3.86E-07 -7.15E-07 PASS 7.15E-07 PASS -3.63E-07 7.61E-09 -3.42E-07 -3.83E-07 -7.65E-07 PASS 7.65E-07 PASS -3.71E-07 7.74E-09 -3.50E-07 -3.92E-07 -8.15E-07 PASS 8.15E-07 PASS -3.78E-07 8.28E-09 -3.55E-07 -4.01E-07 -8.15E-07 PASS 8.15E-07 PASS -3.95E-07 8.17E-09 -3.72E-07 -4.17E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 102 -3.95E-07 7.97E-09 -3.73E-07 -4.17E-07 -8.65E-07 PASS 8.65E-07 PASS -3.79E-07 8.96E-09 -3.55E-07 -4.04E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.46. Plot of +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 103 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.46. Raw data for +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.50E-07 -3.66E-07 -3.62E-07 -3.81E-07 -3.74E-07 -3.74E-07 -3.60E-07 -3.66E-07 -3.68E-07 -3.66E-07 -3.35E-07 -3.55E-07 10 -3.60E-07 -3.77E-07 -3.78E-07 -3.95E-07 -3.88E-07 -3.76E-07 -3.63E-07 -3.69E-07 -3.72E-07 -3.70E-07 -3.34E-07 -3.57E-07 Total Dose (krad(Si)) 20 30 -3.68E-07 -3.74E-07 -3.87E-07 -3.93E-07 -3.88E-07 -3.92E-07 -4.06E-07 -4.08E-07 -3.99E-07 -4.03E-07 -3.84E-07 -3.90E-07 -3.73E-07 -3.80E-07 -3.77E-07 -3.86E-07 -3.78E-07 -3.84E-07 -3.76E-07 -3.83E-07 -3.35E-07 -3.35E-07 -3.54E-07 -3.55E-07 50 -3.91E-07 -4.08E-07 -4.08E-07 -4.24E-07 -4.18E-07 -4.06E-07 -3.99E-07 -4.05E-07 -4.03E-07 -4.01E-07 -3.38E-07 -3.54E-07 24 Hr Anneal 60 -3.91E-07 -4.10E-07 -4.09E-07 -4.25E-07 -4.17E-07 -4.05E-07 -3.98E-07 -4.04E-07 -4.03E-07 -4.03E-07 -3.39E-07 -3.57E-07 168 Hr Anneal 70 -3.74E-07 -3.89E-07 -3.90E-07 -4.06E-07 -3.99E-07 -3.92E-07 -3.80E-07 -3.88E-07 -3.87E-07 -3.87E-07 -3.38E-07 -3.60E-07 -3.67E-07 -3.80E-07 -3.89E-07 -3.94E-07 -4.10E-07 -4.10E-07 -3.92E-07 1.17E-08 1.32E-08 1.45E-08 1.31E-08 1.26E-08 1.27E-08 1.21E-08 -3.34E-07 -3.43E-07 -3.50E-07 -3.58E-07 -3.75E-07 -3.75E-07 -3.58E-07 -3.99E-07 -4.16E-07 -4.29E-07 -4.30E-07 -4.44E-07 -4.45E-07 -4.25E-07 -3.67E-07 4.96E-09 -3.53E-07 -3.80E-07 -7.15E-07 PASS 7.15E-07 PASS -3.70E-07 4.77E-09 -3.57E-07 -3.83E-07 -7.65E-07 PASS 7.65E-07 PASS -3.78E-07 4.31E-09 -3.66E-07 -3.90E-07 -8.15E-07 PASS 8.15E-07 PASS -3.85E-07 3.91E-09 -3.74E-07 -3.95E-07 -8.15E-07 PASS 8.15E-07 PASS -4.03E-07 3.08E-09 -3.94E-07 -4.11E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 104 -4.02E-07 2.70E-09 -3.95E-07 -4.10E-07 -8.65E-07 PASS 8.65E-07 PASS -3.87E-07 4.27E-09 -3.75E-07 -3.98E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.47. Plot of -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 105 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.47. Raw data for -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.51E-07 -3.62E-07 -3.72E-07 -3.89E-07 -3.74E-07 -3.78E-07 -3.59E-07 -3.65E-07 -3.65E-07 -3.71E-07 -3.35E-07 -3.60E-07 10 -3.60E-07 -3.74E-07 -3.88E-07 -4.04E-07 -3.87E-07 -3.83E-07 -3.61E-07 -3.67E-07 -3.69E-07 -3.75E-07 -3.33E-07 -3.58E-07 Total Dose (krad(Si)) 20 30 -3.64E-07 -3.72E-07 -3.83E-07 -3.87E-07 -3.95E-07 -3.98E-07 -4.10E-07 -4.16E-07 -3.96E-07 -4.00E-07 -3.89E-07 -3.98E-07 -3.71E-07 -3.76E-07 -3.74E-07 -3.81E-07 -3.74E-07 -3.81E-07 -3.81E-07 -3.87E-07 -3.34E-07 -3.33E-07 -3.55E-07 -3.57E-07 50 -3.87E-07 -4.02E-07 -4.14E-07 -4.29E-07 -4.15E-07 -4.13E-07 -3.94E-07 -4.02E-07 -4.00E-07 -4.05E-07 -3.36E-07 -3.54E-07 24 Hr Anneal 60 -3.85E-07 -4.02E-07 -4.12E-07 -4.29E-07 -4.14E-07 -4.12E-07 -3.94E-07 -4.00E-07 -3.98E-07 -4.05E-07 -3.37E-07 -3.58E-07 168 Hr Anneal 70 -3.74E-07 -3.85E-07 -3.96E-07 -4.11E-07 -3.97E-07 -3.97E-07 -3.78E-07 -3.86E-07 -3.83E-07 -3.90E-07 -3.36E-07 -3.61E-07 -3.70E-07 -3.83E-07 -3.90E-07 -3.95E-07 -4.09E-07 -4.08E-07 -3.92E-07 1.44E-08 1.67E-08 1.71E-08 1.62E-08 1.57E-08 1.62E-08 1.40E-08 -3.30E-07 -3.37E-07 -3.43E-07 -3.50E-07 -3.66E-07 -3.64E-07 -3.54E-07 -4.09E-07 -4.28E-07 -4.37E-07 -4.39E-07 -4.52E-07 -4.53E-07 -4.31E-07 -3.68E-07 7.20E-09 -3.48E-07 -3.88E-07 -7.15E-07 PASS 7.15E-07 PASS -3.71E-07 8.12E-09 -3.49E-07 -3.93E-07 -7.65E-07 PASS 7.65E-07 PASS -3.78E-07 7.34E-09 -3.58E-07 -3.98E-07 -8.15E-07 PASS 8.15E-07 PASS -3.85E-07 8.24E-09 -3.62E-07 -4.07E-07 -8.15E-07 PASS 8.15E-07 PASS -4.03E-07 7.01E-09 -3.84E-07 -4.22E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 106 -4.02E-07 6.91E-09 -3.83E-07 -4.21E-07 -8.65E-07 PASS 8.65E-07 PASS -3.87E-07 7.30E-09 -3.67E-07 -4.07E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.48. Plot of -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 107 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.48. Raw data for -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.40E-07 -3.86E-07 -3.68E-07 -3.72E-07 -3.59E-07 -3.69E-07 -3.64E-07 -3.59E-07 -3.57E-07 -3.60E-07 -3.73E-07 -3.69E-07 10 -3.54E-07 -3.98E-07 -3.83E-07 -3.84E-07 -3.73E-07 -3.72E-07 -3.67E-07 -3.64E-07 -3.61E-07 -3.63E-07 -3.69E-07 -3.70E-07 Total Dose (krad(Si)) 20 30 -3.60E-07 -3.66E-07 -4.05E-07 -4.09E-07 -3.90E-07 -3.96E-07 -3.94E-07 -3.99E-07 -3.83E-07 -3.87E-07 -3.79E-07 -3.87E-07 -3.76E-07 -3.83E-07 -3.71E-07 -3.79E-07 -3.65E-07 -3.72E-07 -3.71E-07 -3.77E-07 -3.69E-07 -3.71E-07 -3.67E-07 -3.68E-07 50 -3.84E-07 -4.23E-07 -4.07E-07 -4.10E-07 -4.03E-07 -4.03E-07 -4.02E-07 -3.98E-07 -3.89E-07 -3.96E-07 -3.74E-07 -3.66E-07 24 Hr Anneal 60 -3.83E-07 -4.24E-07 -4.08E-07 -4.13E-07 -4.00E-07 -4.03E-07 -4.00E-07 -3.97E-07 -3.88E-07 -3.97E-07 -3.74E-07 -3.69E-07 168 Hr Anneal 70 -3.67E-07 -4.06E-07 -3.92E-07 -3.94E-07 -3.82E-07 -3.88E-07 -3.83E-07 -3.82E-07 -3.74E-07 -3.80E-07 -3.72E-07 -3.74E-07 -3.65E-07 -3.78E-07 -3.86E-07 -3.91E-07 -4.05E-07 -4.06E-07 -3.88E-07 1.72E-08 1.63E-08 1.65E-08 1.60E-08 1.42E-08 1.52E-08 1.46E-08 -3.18E-07 -3.33E-07 -3.41E-07 -3.47E-07 -3.66E-07 -3.64E-07 -3.48E-07 -4.12E-07 -4.23E-07 -4.32E-07 -4.35E-07 -4.44E-07 -4.47E-07 -4.28E-07 -3.62E-07 4.70E-09 -3.49E-07 -3.75E-07 -7.15E-07 PASS 7.15E-07 PASS -3.66E-07 4.54E-09 -3.53E-07 -3.78E-07 -7.65E-07 PASS 7.65E-07 PASS -3.73E-07 5.49E-09 -3.57E-07 -3.88E-07 -8.15E-07 PASS 8.15E-07 PASS -3.80E-07 5.68E-09 -3.64E-07 -3.95E-07 -8.15E-07 PASS 8.15E-07 PASS -3.98E-07 5.44E-09 -3.83E-07 -4.13E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 108 -3.97E-07 5.36E-09 -3.82E-07 -4.12E-07 -8.65E-07 PASS 8.65E-07 PASS -3.81E-07 5.27E-09 -3.67E-07 -3.96E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.49. Plot of -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 109 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.49. Raw data for -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.38E-07 -3.80E-07 -3.71E-07 -3.73E-07 -3.51E-07 -3.71E-07 -3.62E-07 -3.58E-07 -3.54E-07 -3.58E-07 -3.69E-07 -3.71E-07 10 -3.50E-07 -3.94E-07 -3.86E-07 -3.85E-07 -3.65E-07 -3.75E-07 -3.65E-07 -3.62E-07 -3.57E-07 -3.61E-07 -3.67E-07 -3.71E-07 Total Dose (krad(Si)) 20 30 -3.56E-07 -3.62E-07 -4.00E-07 -4.04E-07 -3.93E-07 -3.98E-07 -3.97E-07 -3.99E-07 -3.73E-07 -3.77E-07 -3.81E-07 -3.90E-07 -3.72E-07 -3.79E-07 -3.69E-07 -3.74E-07 -3.61E-07 -3.68E-07 -3.68E-07 -3.75E-07 -3.67E-07 -3.67E-07 -3.68E-07 -3.70E-07 50 -3.77E-07 -4.17E-07 -4.12E-07 -4.13E-07 -3.90E-07 -4.06E-07 -3.96E-07 -3.92E-07 -3.86E-07 -3.94E-07 -3.72E-07 -3.68E-07 24 Hr Anneal 60 -3.76E-07 -4.20E-07 -4.14E-07 -4.15E-07 -3.90E-07 -4.04E-07 -3.94E-07 -3.92E-07 -3.84E-07 -3.94E-07 -3.73E-07 -3.71E-07 168 Hr Anneal 70 -3.63E-07 -4.00E-07 -3.94E-07 -3.96E-07 -3.76E-07 -3.91E-07 -3.80E-07 -3.78E-07 -3.70E-07 -3.79E-07 -3.72E-07 -3.72E-07 -3.63E-07 -3.76E-07 -3.84E-07 -3.88E-07 -4.02E-07 -4.03E-07 -3.86E-07 1.76E-08 1.79E-08 1.89E-08 1.79E-08 1.72E-08 1.88E-08 1.59E-08 -3.14E-07 -3.27E-07 -3.32E-07 -3.39E-07 -3.55E-07 -3.51E-07 -3.42E-07 -4.11E-07 -4.25E-07 -4.36E-07 -4.37E-07 -4.49E-07 -4.54E-07 -4.30E-07 -3.60E-07 6.75E-09 -3.42E-07 -3.79E-07 -7.15E-07 PASS 7.15E-07 PASS -3.64E-07 6.96E-09 -3.45E-07 -3.83E-07 -7.65E-07 PASS 7.65E-07 PASS -3.70E-07 7.17E-09 -3.51E-07 -3.90E-07 -8.15E-07 PASS 8.15E-07 PASS -3.77E-07 7.83E-09 -3.56E-07 -3.99E-07 -8.15E-07 PASS 8.15E-07 PASS -3.95E-07 7.47E-09 -3.74E-07 -4.15E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 110 -3.94E-07 6.96E-09 -3.75E-07 -4.13E-07 -8.65E-07 PASS 8.65E-07 PASS -3.80E-07 7.35E-09 -3.59E-07 -4.00E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.50. Plot of -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 111 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.50. Raw data for -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.48E-07 -3.61E-07 -3.74E-07 -3.85E-07 -3.68E-07 -3.73E-07 -3.63E-07 -3.63E-07 -3.75E-07 -3.66E-07 -3.34E-07 -3.51E-07 10 -3.57E-07 -3.72E-07 -3.87E-07 -3.96E-07 -3.81E-07 -3.74E-07 -3.66E-07 -3.67E-07 -3.78E-07 -3.69E-07 -3.32E-07 -3.50E-07 Total Dose (krad(Si)) 20 30 -3.62E-07 -3.70E-07 -3.81E-07 -3.86E-07 -3.94E-07 -3.98E-07 -4.05E-07 -4.09E-07 -3.92E-07 -3.95E-07 -3.84E-07 -3.90E-07 -3.76E-07 -3.82E-07 -3.73E-07 -3.81E-07 -3.85E-07 -3.91E-07 -3.75E-07 -3.82E-07 -3.33E-07 -3.32E-07 -3.46E-07 -3.49E-07 50 -3.88E-07 -4.00E-07 -4.12E-07 -4.25E-07 -4.11E-07 -4.06E-07 -4.01E-07 -4.00E-07 -4.09E-07 -3.99E-07 -3.35E-07 -3.47E-07 24 Hr Anneal 60 -3.86E-07 -4.00E-07 -4.12E-07 -4.25E-07 -4.09E-07 -4.04E-07 -4.01E-07 -3.99E-07 -4.07E-07 -4.00E-07 -3.36E-07 -3.50E-07 168 Hr Anneal 70 -3.70E-07 -3.82E-07 -3.96E-07 -4.05E-07 -3.91E-07 -3.90E-07 -3.82E-07 -3.84E-07 -3.93E-07 -3.84E-07 -3.35E-07 -3.52E-07 -3.67E-07 -3.79E-07 -3.87E-07 -3.92E-07 -4.07E-07 -4.06E-07 -3.89E-07 1.38E-08 1.47E-08 1.62E-08 1.46E-08 1.39E-08 1.48E-08 1.32E-08 -3.29E-07 -3.38E-07 -3.43E-07 -3.52E-07 -3.69E-07 -3.66E-07 -3.53E-07 -4.05E-07 -4.19E-07 -4.31E-07 -4.32E-07 -4.45E-07 -4.47E-07 -4.25E-07 -3.68E-07 5.86E-09 -3.52E-07 -3.84E-07 -7.15E-07 PASS 7.15E-07 PASS -3.71E-07 4.90E-09 -3.57E-07 -3.84E-07 -7.65E-07 PASS 7.65E-07 PASS -3.79E-07 5.32E-09 -3.64E-07 -3.93E-07 -8.15E-07 PASS 8.15E-07 PASS -3.85E-07 5.01E-09 -3.71E-07 -3.99E-07 -8.15E-07 PASS 8.15E-07 PASS -4.03E-07 4.12E-09 -3.92E-07 -4.14E-07 -8.65E-07 PASS 8.65E-07 PASS An ISO 9001:2008 and DSCC Certified Company 112 -4.02E-07 3.37E-09 -3.93E-07 -4.11E-07 -8.65E-07 PASS 8.65E-07 PASS -3.87E-07 4.78E-09 -3.74E-07 -4.00E-07 -8.65E-07 PASS 8.65E-07 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.51. Plot of Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 113 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.51. Raw data for Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High1 1 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=0mA Device 0 10 20 30 50 60 70 557 6.22E-03 6.53E-03 6.42E-03 6.60E-03 6.56E-03 6.37E-03 6.50E-03 563 6.24E-03 6.71E-03 6.84E-03 6.62E-03 6.79E-03 6.87E-03 6.67E-03 564 6.44E-03 6.45E-03 6.77E-03 7.10E-03 6.86E-03 6.87E-03 6.70E-03 567 6.41E-03 6.77E-03 6.77E-03 6.87E-03 7.00E-03 7.01E-03 6.77E-03 569 6.51E-03 6.46E-03 6.72E-03 6.51E-03 6.69E-03 6.80E-03 6.47E-03 570 6.27E-03 6.53E-03 6.55E-03 6.72E-03 7.10E-03 6.75E-03 6.69E-03 571 6.30E-03 6.41E-03 6.66E-03 6.41E-03 7.01E-03 6.67E-03 6.54E-03 572 6.51E-03 6.60E-03 6.60E-03 6.53E-03 6.83E-03 6.75E-03 6.62E-03 573 6.63E-03 6.71E-03 6.89E-03 6.87E-03 6.90E-03 7.01E-03 6.59E-03 574 6.29E-03 6.21E-03 6.49E-03 6.30E-03 6.54E-03 6.53E-03 6.32E-03 584 6.15E-03 6.41E-03 6.47E-03 6.21E-03 6.34E-03 6.40E-03 6.27E-03 585 6.14E-03 6.39E-03 6.40E-03 6.50E-03 6.85E-03 6.40E-03 6.27E-03 Biased Statistics Average Biased 6.36E-03 6.58E-03 6.70E-03 6.74E-03 6.78E-03 6.78E-03 6.62E-03 Std Dev Biased 1.28E-04 1.47E-04 1.64E-04 2.42E-04 1.67E-04 2.44E-04 1.31E-04 Ps90%/90% (+KTL) Biased 6.71E-03 6.99E-03 7.15E-03 7.40E-03 7.24E-03 7.45E-03 6.98E-03 Ps90%/90% (-KTL) Biased 6.01E-03 6.18E-03 6.25E-03 6.08E-03 6.32E-03 6.12E-03 6.26E-03 Un-Biased Statistics Average Un-Biased 6.40E-03 6.49E-03 6.64E-03 6.57E-03 6.88E-03 6.74E-03 6.55E-03 Std Dev Un-Biased 1.61E-04 1.92E-04 1.54E-04 2.30E-04 2.14E-04 1.75E-04 1.41E-04 Ps90%/90% (+KTL) Un-Biased 6.84E-03 7.02E-03 7.06E-03 7.20E-03 7.46E-03 7.22E-03 6.94E-03 Ps90%/90% (-KTL) Un-Biased 5.96E-03 5.97E-03 6.22E-03 5.93E-03 6.29E-03 6.26E-03 6.17E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 114 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.52. Plot of Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 115 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.52. Raw data for Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High1 2 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=0mA Device 0 10 20 30 50 60 70 557 6.19E-03 6.48E-03 6.55E-03 6.70E-03 6.47E-03 6.42E-03 6.50E-03 563 6.68E-03 7.02E-03 7.16E-03 6.88E-03 7.20E-03 7.12E-03 7.09E-03 564 6.73E-03 6.78E-03 7.14E-03 7.19E-03 7.01E-03 7.12E-03 6.87E-03 567 6.52E-03 7.03E-03 6.98E-03 6.90E-03 7.13E-03 7.14E-03 6.87E-03 569 6.44E-03 6.65E-03 6.74E-03 6.78E-03 7.00E-03 6.85E-03 6.64E-03 570 6.52E-03 6.80E-03 6.81E-03 6.62E-03 7.15E-03 6.87E-03 6.72E-03 571 6.49E-03 6.45E-03 6.64E-03 6.50E-03 7.11E-03 6.77E-03 6.57E-03 572 6.51E-03 6.56E-03 6.62E-03 6.60E-03 6.85E-03 6.69E-03 6.65E-03 573 6.64E-03 6.87E-03 7.03E-03 6.73E-03 7.13E-03 7.11E-03 6.87E-03 574 6.37E-03 6.38E-03 6.74E-03 6.46E-03 6.61E-03 6.57E-03 6.54E-03 584 6.69E-03 6.95E-03 6.86E-03 6.65E-03 6.90E-03 6.70E-03 6.67E-03 585 6.59E-03 6.85E-03 6.87E-03 6.82E-03 7.08E-03 6.79E-03 6.62E-03 Biased Statistics Average Biased 6.51E-03 6.79E-03 6.91E-03 6.89E-03 6.96E-03 6.93E-03 6.79E-03 Std Dev Biased 2.15E-04 2.38E-04 2.64E-04 1.86E-04 2.88E-04 3.09E-04 2.29E-04 Ps90%/90% (+KTL) Biased 7.10E-03 7.44E-03 7.64E-03 7.40E-03 7.75E-03 7.78E-03 7.42E-03 Ps90%/90% (-KTL) Biased 5.92E-03 6.14E-03 6.19E-03 6.38E-03 6.17E-03 6.08E-03 6.17E-03 Un-Biased Statistics Average Un-Biased 6.51E-03 6.61E-03 6.77E-03 6.58E-03 6.97E-03 6.80E-03 6.67E-03 Std Dev Un-Biased 9.61E-05 2.15E-04 1.65E-04 1.06E-04 2.35E-04 2.04E-04 1.32E-04 Ps90%/90% (+KTL) Un-Biased 6.77E-03 7.20E-03 7.22E-03 6.87E-03 7.62E-03 7.36E-03 7.03E-03 Ps90%/90% (-KTL) Un-Biased 6.24E-03 6.02E-03 6.31E-03 6.29E-03 6.32E-03 6.24E-03 6.31E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 116 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.53. Plot of Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 117 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.53. Raw data for Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High1 3 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=0mA Device 0 10 20 30 50 60 70 557 6.32E-03 6.43E-03 6.44E-03 6.65E-03 6.54E-03 6.55E-03 6.43E-03 563 6.64E-03 7.22E-03 7.19E-03 6.97E-03 7.23E-03 7.33E-03 7.14E-03 564 6.78E-03 6.85E-03 7.03E-03 7.22E-03 7.05E-03 7.04E-03 6.99E-03 567 6.71E-03 6.83E-03 7.09E-03 6.82E-03 7.13E-03 7.06E-03 6.94E-03 569 6.56E-03 6.75E-03 6.86E-03 6.75E-03 6.91E-03 6.85E-03 6.64E-03 570 6.78E-03 6.75E-03 6.66E-03 6.77E-03 7.11E-03 6.85E-03 6.99E-03 571 6.52E-03 6.50E-03 6.55E-03 6.60E-03 7.10E-03 6.67E-03 6.67E-03 572 6.54E-03 6.61E-03 6.69E-03 6.62E-03 6.85E-03 6.69E-03 6.55E-03 573 6.66E-03 6.87E-03 7.01E-03 7.00E-03 7.13E-03 7.21E-03 6.87E-03 574 6.49E-03 6.48E-03 6.71E-03 6.48E-03 6.56E-03 6.48E-03 6.50E-03 584 6.74E-03 6.85E-03 7.01E-03 6.67E-03 6.83E-03 6.75E-03 6.79E-03 585 6.84E-03 6.97E-03 6.81E-03 6.85E-03 7.15E-03 6.69E-03 6.74E-03 Biased Statistics Average Biased 6.60E-03 6.82E-03 6.92E-03 6.88E-03 6.97E-03 6.97E-03 6.83E-03 Std Dev Biased 1.78E-04 2.82E-04 2.95E-04 2.22E-04 2.68E-04 2.89E-04 2.87E-04 Ps90%/90% (+KTL) Biased 7.09E-03 7.59E-03 7.73E-03 7.49E-03 7.71E-03 7.76E-03 7.62E-03 Ps90%/90% (-KTL) Biased 6.12E-03 6.04E-03 6.11E-03 6.27E-03 6.24E-03 6.17E-03 6.04E-03 Un-Biased Statistics Average Un-Biased 6.60E-03 6.64E-03 6.72E-03 6.69E-03 6.95E-03 6.78E-03 6.72E-03 Std Dev Un-Biased 1.20E-04 1.67E-04 1.71E-04 2.00E-04 2.46E-04 2.74E-04 2.09E-04 Ps90%/90% (+KTL) Un-Biased 6.93E-03 7.10E-03 7.19E-03 7.24E-03 7.63E-03 7.53E-03 7.29E-03 Ps90%/90% (-KTL) Un-Biased 6.27E-03 6.19E-03 6.25E-03 6.15E-03 6.27E-03 6.03E-03 6.14E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 118 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.54. Plot of Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 119 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.54. Raw data for Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High1 4 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=0mA Device 0 10 20 30 50 60 70 557 6.31E-03 6.65E-03 6.72E-03 6.75E-03 6.73E-03 6.58E-03 6.62E-03 563 6.64E-03 6.92E-03 6.91E-03 6.63E-03 6.95E-03 7.01E-03 7.01E-03 564 6.78E-03 6.85E-03 7.06E-03 7.17E-03 7.17E-03 7.14E-03 7.06E-03 567 6.83E-03 6.92E-03 7.06E-03 7.00E-03 6.93E-03 7.06E-03 6.86E-03 569 6.56E-03 6.73E-03 6.79E-03 6.77E-03 7.01E-03 6.85E-03 6.77E-03 570 6.66E-03 6.63E-03 6.84E-03 6.65E-03 7.17E-03 6.79E-03 6.92E-03 571 6.61E-03 6.48E-03 6.52E-03 6.58E-03 7.08E-03 6.80E-03 6.75E-03 572 6.59E-03 6.75E-03 6.84E-03 6.94E-03 7.03E-03 6.79E-03 6.81E-03 573 6.81E-03 6.80E-03 7.06E-03 6.99E-03 7.15E-03 7.19E-03 6.84E-03 574 6.63E-03 6.53E-03 6.69E-03 6.65E-03 6.71E-03 6.72E-03 6.67E-03 584 6.56E-03 6.65E-03 6.60E-03 6.51E-03 6.56E-03 6.48E-03 6.35E-03 585 6.46E-03 6.53E-03 6.47E-03 6.50E-03 6.80E-03 6.67E-03 6.40E-03 Biased Statistics Average Biased 6.62E-03 6.81E-03 6.91E-03 6.86E-03 6.96E-03 6.93E-03 6.86E-03 Std Dev Biased 2.06E-04 1.20E-04 1.54E-04 2.17E-04 1.58E-04 2.22E-04 1.79E-04 Ps90%/90% (+KTL) Biased 7.19E-03 7.14E-03 7.33E-03 7.46E-03 7.39E-03 7.54E-03 7.35E-03 Ps90%/90% (-KTL) Biased 6.06E-03 6.48E-03 6.48E-03 6.27E-03 6.52E-03 6.32E-03 6.37E-03 Un-Biased Statistics Average Un-Biased 6.66E-03 6.64E-03 6.79E-03 6.76E-03 7.03E-03 6.86E-03 6.80E-03 Std Dev Un-Biased 8.77E-05 1.37E-04 2.00E-04 1.88E-04 1.86E-04 1.88E-04 9.42E-05 Ps90%/90% (+KTL) Un-Biased 6.90E-03 7.01E-03 7.34E-03 7.28E-03 7.54E-03 7.37E-03 7.06E-03 Ps90%/90% (-KTL) Un-Biased 6.42E-03 6.26E-03 6.24E-03 6.25E-03 6.52E-03 6.34E-03 6.54E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 120 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.55. Plot of Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 121 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.55. Raw data for Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High2 1 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=1mA Device 0 10 20 30 50 60 70 557 7.01E-02 7.05E-02 7.07E-02 7.11E-02 7.12E-02 7.10E-02 7.10E-02 563 7.44E-02 7.51E-02 7.54E-02 7.54E-02 7.54E-02 7.57E-02 7.56E-02 564 7.55E-02 7.61E-02 7.66E-02 7.73E-02 7.69E-02 7.70E-02 7.68E-02 567 7.54E-02 7.61E-02 7.66E-02 7.69E-02 7.67E-02 7.68E-02 7.65E-02 569 7.37E-02 7.45E-02 7.49E-02 7.50E-02 7.50E-02 7.49E-02 7.48E-02 570 7.47E-02 7.47E-02 7.51E-02 7.53E-02 7.59E-02 7.55E-02 7.52E-02 571 7.41E-02 7.41E-02 7.45E-02 7.48E-02 7.57E-02 7.50E-02 7.49E-02 572 7.42E-02 7.44E-02 7.51E-02 7.52E-02 7.56E-02 7.50E-02 7.51E-02 573 7.55E-02 7.60E-02 7.62E-02 7.63E-02 7.66E-02 7.67E-02 7.61E-02 574 7.32E-02 7.30E-02 7.37E-02 7.38E-02 7.39E-02 7.38E-02 7.37E-02 584 7.10E-02 7.14E-02 7.13E-02 7.10E-02 7.09E-02 7.07E-02 7.07E-02 585 7.09E-02 7.08E-02 7.15E-02 7.10E-02 7.11E-02 7.04E-02 7.07E-02 Biased Statistics Average Biased 7.38E-02 7.44E-02 7.48E-02 7.51E-02 7.51E-02 7.51E-02 7.50E-02 Std Dev Biased 2.21E-03 2.29E-03 2.45E-03 2.45E-03 2.27E-03 2.44E-03 2.32E-03 Ps90%/90% (+KTL) Biased 7.99E-02 8.07E-02 8.16E-02 8.18E-02 8.13E-02 8.17E-02 8.13E-02 Ps90%/90% (-KTL) Biased 6.77E-02 6.82E-02 6.81E-02 6.84E-02 6.88E-02 6.84E-02 6.86E-02 Un-Biased Statistics Average Un-Biased 7.43E-02 7.44E-02 7.49E-02 7.51E-02 7.56E-02 7.52E-02 7.50E-02 Std Dev Un-Biased 8.47E-04 1.07E-03 9.26E-04 9.21E-04 1.01E-03 1.03E-03 8.78E-04 Ps90%/90% (+KTL) Un-Biased 7.67E-02 7.74E-02 7.75E-02 7.76E-02 7.83E-02 7.80E-02 7.74E-02 Ps90%/90% (-KTL) Un-Biased 7.20E-02 7.15E-02 7.24E-02 7.26E-02 7.28E-02 7.23E-02 7.26E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 122 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.56. Plot of Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 123 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.56. Raw data for Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High2 2 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=1mA Device 0 10 20 30 50 60 70 557 6.71E-02 6.76E-02 6.79E-02 6.82E-02 6.84E-02 6.79E-02 6.80E-02 563 7.57E-02 7.62E-02 7.66E-02 7.68E-02 7.68E-02 7.68E-02 7.67E-02 564 7.51E-02 7.57E-02 7.64E-02 7.70E-02 7.68E-02 7.67E-02 7.64E-02 567 7.58E-02 7.67E-02 7.71E-02 7.71E-02 7.73E-02 7.73E-02 7.68E-02 569 7.26E-02 7.33E-02 7.38E-02 7.39E-02 7.39E-02 7.39E-02 7.34E-02 570 7.45E-02 7.46E-02 7.49E-02 7.51E-02 7.57E-02 7.54E-02 7.51E-02 571 7.31E-02 7.29E-02 7.33E-02 7.38E-02 7.45E-02 7.37E-02 7.35E-02 572 7.11E-02 7.09E-02 7.16E-02 7.18E-02 7.20E-02 7.18E-02 7.15E-02 573 7.55E-02 7.60E-02 7.63E-02 7.64E-02 7.69E-02 7.66E-02 7.60E-02 574 7.03E-02 7.03E-02 7.12E-02 7.11E-02 7.14E-02 7.11E-02 7.12E-02 584 7.44E-02 7.49E-02 7.49E-02 7.47E-02 7.43E-02 7.40E-02 7.40E-02 585 7.47E-02 7.46E-02 7.50E-02 7.49E-02 7.51E-02 7.40E-02 7.44E-02 Biased Statistics Average Biased 7.33E-02 7.39E-02 7.44E-02 7.46E-02 7.46E-02 7.45E-02 7.43E-02 Std Dev Biased 3.68E-03 3.76E-03 3.86E-03 3.80E-03 3.73E-03 3.94E-03 3.75E-03 Ps90%/90% (+KTL) Biased 8.34E-02 8.42E-02 8.49E-02 8.50E-02 8.49E-02 8.53E-02 8.45E-02 Ps90%/90% (-KTL) Biased 6.32E-02 6.36E-02 6.38E-02 6.42E-02 6.44E-02 6.37E-02 6.40E-02 Un-Biased Statistics Average Un-Biased 7.29E-02 7.29E-02 7.35E-02 7.36E-02 7.41E-02 7.37E-02 7.35E-02 Std Dev Un-Biased 2.20E-03 2.42E-03 2.16E-03 2.21E-03 2.35E-03 2.35E-03 2.12E-03 Ps90%/90% (+KTL) Un-Biased 7.89E-02 7.96E-02 7.94E-02 7.97E-02 8.05E-02 8.02E-02 7.93E-02 Ps90%/90% (-KTL) Un-Biased 6.69E-02 6.63E-02 6.75E-02 6.76E-02 6.77E-02 6.73E-02 6.76E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 124 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.57. Plot of Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 125 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.57. Raw data for Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High2 3 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=1mA Device 0 10 20 30 50 60 70 557 6.76E-02 6.79E-02 6.81E-02 6.86E-02 6.85E-02 6.84E-02 6.83E-02 563 7.60E-02 7.67E-02 7.69E-02 7.71E-02 7.73E-02 7.73E-02 7.72E-02 564 7.49E-02 7.56E-02 7.62E-02 7.67E-02 7.64E-02 7.64E-02 7.62E-02 567 7.56E-02 7.64E-02 7.69E-02 7.72E-02 7.72E-02 7.70E-02 7.68E-02 569 7.25E-02 7.33E-02 7.36E-02 7.38E-02 7.40E-02 7.39E-02 7.35E-02 570 7.47E-02 7.48E-02 7.47E-02 7.56E-02 7.57E-02 7.56E-02 7.54E-02 571 7.27E-02 7.28E-02 7.32E-02 7.35E-02 7.43E-02 7.37E-02 7.36E-02 572 7.11E-02 7.11E-02 7.18E-02 7.19E-02 7.21E-02 7.18E-02 7.17E-02 573 7.58E-02 7.60E-02 7.65E-02 7.66E-02 7.71E-02 7.69E-02 7.62E-02 574 7.03E-02 7.01E-02 7.08E-02 7.11E-02 7.11E-02 7.13E-02 7.08E-02 584 7.48E-02 7.52E-02 7.47E-02 7.50E-02 7.46E-02 7.43E-02 7.43E-02 585 7.44E-02 7.45E-02 7.49E-02 7.48E-02 7.47E-02 7.39E-02 7.43E-02 Biased Statistics Average Biased 7.33E-02 7.40E-02 7.43E-02 7.47E-02 7.47E-02 7.46E-02 7.44E-02 Std Dev Biased 3.46E-03 3.66E-03 3.74E-03 3.68E-03 3.69E-03 3.69E-03 3.68E-03 Ps90%/90% (+KTL) Biased 8.28E-02 8.40E-02 8.46E-02 8.48E-02 8.48E-02 8.47E-02 8.45E-02 Ps90%/90% (-KTL) Biased 6.38E-02 6.39E-02 6.41E-02 6.46E-02 6.45E-02 6.45E-02 6.43E-02 Un-Biased Statistics Average Un-Biased 7.29E-02 7.30E-02 7.34E-02 7.38E-02 7.41E-02 7.39E-02 7.35E-02 Std Dev Un-Biased 2.30E-03 2.46E-03 2.28E-03 2.36E-03 2.48E-03 2.42E-03 2.34E-03 Ps90%/90% (+KTL) Un-Biased 7.92E-02 7.97E-02 7.96E-02 8.02E-02 8.08E-02 8.05E-02 8.00E-02 Ps90%/90% (-KTL) Un-Biased 6.66E-02 6.62E-02 6.71E-02 6.73E-02 6.73E-02 6.72E-02 6.71E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 126 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.58. Plot of Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 127 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.58. Raw data for Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High2 4 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=1mA Device 0 10 20 30 50 60 70 557 7.02E-02 7.07E-02 7.09E-02 7.13E-02 7.14E-02 7.10E-02 7.10E-02 563 7.43E-02 7.49E-02 7.54E-02 7.55E-02 7.56E-02 7.56E-02 7.54E-02 564 7.55E-02 7.63E-02 7.67E-02 7.74E-02 7.72E-02 7.69E-02 7.70E-02 567 7.54E-02 7.62E-02 7.68E-02 7.68E-02 7.67E-02 7.67E-02 7.65E-02 569 7.39E-02 7.45E-02 7.50E-02 7.50E-02 7.52E-02 7.50E-02 7.47E-02 570 7.45E-02 7.47E-02 7.49E-02 7.52E-02 7.56E-02 7.53E-02 7.51E-02 571 7.42E-02 7.40E-02 7.47E-02 7.50E-02 7.56E-02 7.48E-02 7.47E-02 572 7.43E-02 7.42E-02 7.49E-02 7.51E-02 7.56E-02 7.51E-02 7.48E-02 573 7.54E-02 7.57E-02 7.62E-02 7.64E-02 7.69E-02 7.67E-02 7.59E-02 574 7.30E-02 7.27E-02 7.33E-02 7.35E-02 7.37E-02 7.37E-02 7.34E-02 584 7.11E-02 7.15E-02 7.15E-02 7.13E-02 7.11E-02 7.08E-02 7.09E-02 585 7.10E-02 7.08E-02 7.13E-02 7.09E-02 7.10E-02 7.03E-02 7.06E-02 Biased Statistics Average Biased 7.39E-02 7.45E-02 7.50E-02 7.52E-02 7.52E-02 7.50E-02 7.49E-02 Std Dev Biased 2.17E-03 2.27E-03 2.43E-03 2.40E-03 2.30E-03 2.37E-03 2.36E-03 Ps90%/90% (+KTL) Biased 7.98E-02 8.07E-02 8.16E-02 8.17E-02 8.15E-02 8.15E-02 8.14E-02 Ps90%/90% (-KTL) Biased 6.79E-02 6.83E-02 6.83E-02 6.86E-02 6.89E-02 6.85E-02 6.84E-02 Un-Biased Statistics Average Un-Biased 7.43E-02 7.43E-02 7.48E-02 7.50E-02 7.55E-02 7.51E-02 7.48E-02 Std Dev Un-Biased 8.40E-04 1.08E-03 1.05E-03 1.02E-03 1.16E-03 1.09E-03 8.94E-04 Ps90%/90% (+KTL) Un-Biased 7.66E-02 7.72E-02 7.77E-02 7.78E-02 7.87E-02 7.81E-02 7.72E-02 Ps90%/90% (-KTL) Un-Biased 7.20E-02 7.13E-02 7.19E-02 7.22E-02 7.23E-02 7.21E-02 7.23E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 128 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.59. Plot of Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 129 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.59. Raw data for Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High3 1 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=10mA Device 0 10 20 30 50 60 70 557 3.56E-01 3.57E-01 3.58E-01 3.59E-01 3.59E-01 3.59E-01 3.58E-01 563 3.76E-01 3.78E-01 3.79E-01 3.80E-01 3.81E-01 3.80E-01 3.80E-01 564 3.81E-01 3.84E-01 3.86E-01 3.88E-01 3.88E-01 3.86E-01 3.86E-01 567 3.79E-01 3.83E-01 3.84E-01 3.86E-01 3.86E-01 3.85E-01 3.84E-01 569 3.73E-01 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01 570 3.75E-01 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01 571 3.74E-01 3.73E-01 3.75E-01 3.77E-01 3.79E-01 3.77E-01 3.76E-01 572 3.77E-01 3.77E-01 3.78E-01 3.80E-01 3.81E-01 3.79E-01 3.79E-01 573 3.79E-01 3.80E-01 3.81E-01 3.82E-01 3.84E-01 3.83E-01 3.81E-01 574 3.68E-01 3.68E-01 3.70E-01 3.71E-01 3.72E-01 3.71E-01 3.70E-01 584 3.60E-01 3.62E-01 3.61E-01 3.62E-01 3.60E-01 3.58E-01 3.60E-01 585 3.59E-01 3.59E-01 3.62E-01 3.60E-01 3.60E-01 3.58E-01 3.59E-01 Biased Statistics Average Biased 3.73E-01 3.75E-01 3.77E-01 3.78E-01 3.78E-01 3.78E-01 3.77E-01 Std Dev Biased 1.01E-02 1.09E-02 1.12E-02 1.13E-02 1.13E-02 1.12E-02 1.11E-02 Ps90%/90% (+KTL) Biased 4.01E-01 4.05E-01 4.07E-01 4.09E-01 4.09E-01 4.08E-01 4.07E-01 Ps90%/90% (-KTL) Biased 3.45E-01 3.45E-01 3.46E-01 3.47E-01 3.47E-01 3.47E-01 3.46E-01 Un-Biased Statistics Average Un-Biased 3.74E-01 3.75E-01 3.76E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01 Std Dev Un-Biased 3.91E-03 4.60E-03 4.07E-03 4.20E-03 4.29E-03 4.25E-03 4.01E-03 Ps90%/90% (+KTL) Un-Biased 3.85E-01 3.87E-01 3.87E-01 3.89E-01 3.91E-01 3.89E-01 3.88E-01 Ps90%/90% (-KTL) Un-Biased 3.64E-01 3.62E-01 3.65E-01 3.66E-01 3.67E-01 3.66E-01 3.66E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 130 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.60. Plot of Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 131 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.60. Raw data for Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High3 2 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=10mA Device 0 10 20 30 50 60 70 557 3.46E-01 3.46E-01 3.47E-01 3.49E-01 3.48E-01 3.47E-01 3.47E-01 563 3.81E-01 3.82E-01 3.84E-01 3.85E-01 3.86E-01 3.86E-01 3.85E-01 564 3.81E-01 3.84E-01 3.85E-01 3.88E-01 3.88E-01 3.86E-01 3.85E-01 567 3.82E-01 3.85E-01 3.87E-01 3.88E-01 3.88E-01 3.88E-01 3.86E-01 569 3.69E-01 3.72E-01 3.72E-01 3.74E-01 3.74E-01 3.73E-01 3.72E-01 570 3.75E-01 3.76E-01 3.78E-01 3.79E-01 3.80E-01 3.79E-01 3.78E-01 571 3.68E-01 3.68E-01 3.70E-01 3.71E-01 3.73E-01 3.71E-01 3.70E-01 572 3.60E-01 3.59E-01 3.61E-01 3.62E-01 3.64E-01 3.62E-01 3.61E-01 573 3.80E-01 3.81E-01 3.82E-01 3.84E-01 3.85E-01 3.85E-01 3.82E-01 574 3.58E-01 3.58E-01 3.60E-01 3.61E-01 3.61E-01 3.60E-01 3.60E-01 584 3.76E-01 3.78E-01 3.78E-01 3.77E-01 3.76E-01 3.74E-01 3.75E-01 585 3.76E-01 3.76E-01 3.79E-01 3.77E-01 3.78E-01 3.74E-01 3.75E-01 Biased Statistics Average Biased 3.72E-01 3.74E-01 3.75E-01 3.77E-01 3.77E-01 3.76E-01 3.75E-01 Std Dev Biased 1.55E-02 1.64E-02 1.69E-02 1.68E-02 1.70E-02 1.71E-02 1.66E-02 Ps90%/90% (+KTL) Biased 4.14E-01 4.19E-01 4.21E-01 4.22E-01 4.24E-01 4.23E-01 4.21E-01 Ps90%/90% (-KTL) Biased 3.29E-01 3.29E-01 3.29E-01 3.31E-01 3.30E-01 3.29E-01 3.30E-01 Un-Biased Statistics Average Un-Biased 3.68E-01 3.68E-01 3.70E-01 3.71E-01 3.73E-01 3.71E-01 3.70E-01 Std Dev Un-Biased 9.34E-03 1.01E-02 9.90E-03 9.83E-03 1.02E-02 1.04E-02 9.92E-03 Ps90%/90% (+KTL) Un-Biased 3.94E-01 3.96E-01 3.97E-01 3.98E-01 4.01E-01 4.00E-01 3.97E-01 Ps90%/90% (-KTL) Un-Biased 3.43E-01 3.41E-01 3.43E-01 3.44E-01 3.45E-01 3.43E-01 3.43E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 132 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.61. Plot of Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 133 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.61. Raw data for Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High3 3 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=10mA Device 0 10 20 30 50 60 70 557 3.46E-01 3.47E-01 3.48E-01 3.49E-01 3.49E-01 3.48E-01 3.48E-01 563 3.83E-01 3.86E-01 3.87E-01 3.88E-01 3.89E-01 3.88E-01 3.87E-01 564 3.79E-01 3.82E-01 3.84E-01 3.86E-01 3.86E-01 3.85E-01 3.85E-01 567 3.81E-01 3.84E-01 3.86E-01 3.87E-01 3.87E-01 3.87E-01 3.85E-01 569 3.68E-01 3.72E-01 3.73E-01 3.73E-01 3.74E-01 3.73E-01 3.72E-01 570 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.81E-01 3.80E-01 3.78E-01 571 3.67E-01 3.67E-01 3.69E-01 3.70E-01 3.73E-01 3.70E-01 3.69E-01 572 3.60E-01 3.60E-01 3.61E-01 3.63E-01 3.64E-01 3.62E-01 3.61E-01 573 3.80E-01 3.81E-01 3.83E-01 3.84E-01 3.86E-01 3.85E-01 3.83E-01 574 3.57E-01 3.57E-01 3.59E-01 3.59E-01 3.60E-01 3.60E-01 3.59E-01 584 3.77E-01 3.79E-01 3.78E-01 3.78E-01 3.77E-01 3.76E-01 3.76E-01 585 3.76E-01 3.76E-01 3.78E-01 3.76E-01 3.77E-01 3.74E-01 3.75E-01 Biased Statistics Average Biased 3.71E-01 3.74E-01 3.75E-01 3.77E-01 3.77E-01 3.76E-01 3.75E-01 Std Dev Biased 1.53E-02 1.62E-02 1.63E-02 1.65E-02 1.67E-02 1.67E-02 1.65E-02 Ps90%/90% (+KTL) Biased 4.13E-01 4.18E-01 4.20E-01 4.22E-01 4.23E-01 4.22E-01 4.21E-01 Ps90%/90% (-KTL) Biased 3.30E-01 3.30E-01 3.31E-01 3.31E-01 3.31E-01 3.30E-01 3.30E-01 Un-Biased Statistics Average Un-Biased 3.68E-01 3.68E-01 3.70E-01 3.71E-01 3.73E-01 3.71E-01 3.70E-01 Std Dev Un-Biased 1.00E-02 1.06E-02 1.05E-02 1.05E-02 1.09E-02 1.09E-02 1.06E-02 Ps90%/90% (+KTL) Un-Biased 3.95E-01 3.97E-01 3.99E-01 4.00E-01 4.02E-01 4.01E-01 3.99E-01 Ps90%/90% (-KTL) Un-Biased 3.40E-01 3.39E-01 3.41E-01 3.42E-01 3.43E-01 3.42E-01 3.41E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 134 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.62. Plot of Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 135 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.62. Raw data for Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High3 4 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=10mA Device 0 10 20 30 50 60 70 557 3.56E-01 3.57E-01 3.58E-01 3.59E-01 3.60E-01 3.59E-01 3.58E-01 563 3.76E-01 3.77E-01 3.79E-01 3.80E-01 3.81E-01 3.80E-01 3.79E-01 564 3.82E-01 3.85E-01 3.87E-01 3.89E-01 3.89E-01 3.87E-01 3.87E-01 567 3.79E-01 3.83E-01 3.84E-01 3.85E-01 3.86E-01 3.85E-01 3.84E-01 569 3.73E-01 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01 570 3.75E-01 3.75E-01 3.76E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01 571 3.74E-01 3.74E-01 3.76E-01 3.77E-01 3.80E-01 3.77E-01 3.76E-01 572 3.76E-01 3.76E-01 3.78E-01 3.79E-01 3.80E-01 3.79E-01 3.78E-01 573 3.79E-01 3.80E-01 3.82E-01 3.83E-01 3.85E-01 3.83E-01 3.82E-01 574 3.67E-01 3.67E-01 3.70E-01 3.70E-01 3.71E-01 3.70E-01 3.70E-01 584 3.60E-01 3.62E-01 3.61E-01 3.61E-01 3.60E-01 3.59E-01 3.60E-01 585 3.59E-01 3.59E-01 3.62E-01 3.60E-01 3.60E-01 3.57E-01 3.59E-01 Biased Statistics Average Biased 3.73E-01 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01 Std Dev Biased 1.01E-02 1.10E-02 1.15E-02 1.14E-02 1.14E-02 1.14E-02 1.12E-02 Ps90%/90% (+KTL) Biased 4.01E-01 4.06E-01 4.08E-01 4.09E-01 4.10E-01 4.09E-01 4.08E-01 Ps90%/90% (-KTL) Biased 3.46E-01 3.45E-01 3.46E-01 3.47E-01 3.48E-01 3.47E-01 3.46E-01 Un-Biased Statistics Average Un-Biased 3.74E-01 3.75E-01 3.76E-01 3.77E-01 3.79E-01 3.78E-01 3.76E-01 Std Dev Un-Biased 4.34E-03 4.78E-03 4.33E-03 4.58E-03 4.74E-03 4.67E-03 4.33E-03 Ps90%/90% (+KTL) Un-Biased 3.86E-01 3.88E-01 3.88E-01 3.90E-01 3.92E-01 3.90E-01 3.88E-01 Ps90%/90% (-KTL) Un-Biased 3.62E-01 3.62E-01 3.64E-01 3.65E-01 3.66E-01 3.65E-01 3.65E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 136 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.63. Plot of Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 137 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.63. Raw data for Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low1 1 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=0mA 60 70 Device 0 10 20 30 50 557 1.89E-02 1.90E-02 1.91E-02 1.92E-02 1.93E-02 1.92E-02 1.92E-02 563 1.79E-02 1.79E-02 1.80E-02 1.81E-02 1.83E-02 1.82E-02 1.81E-02 564 1.77E-02 1.78E-02 1.79E-02 1.81E-02 1.82E-02 1.80E-02 1.79E-02 567 1.75E-02 1.77E-02 1.79E-02 1.80E-02 1.80E-02 1.80E-02 1.78E-02 569 1.76E-02 1.78E-02 1.79E-02 1.79E-02 1.81E-02 1.80E-02 1.79E-02 570 1.77E-02 1.79E-02 1.80E-02 1.79E-02 1.80E-02 1.82E-02 1.79E-02 571 1.82E-02 1.80E-02 1.83E-02 1.83E-02 1.86E-02 1.84E-02 1.82E-02 572 1.83E-02 1.82E-02 1.85E-02 1.83E-02 1.85E-02 1.84E-02 1.85E-02 573 1.78E-02 1.82E-02 1.81E-02 1.82E-02 1.83E-02 1.83E-02 1.81E-02 574 1.82E-02 1.81E-02 1.84E-02 1.84E-02 1.86E-02 1.85E-02 1.83E-02 584 1.87E-02 1.88E-02 1.91E-02 1.89E-02 1.88E-02 1.89E-02 1.87E-02 585 1.86E-02 1.87E-02 1.90E-02 1.88E-02 1.87E-02 1.85E-02 1.85E-02 Biased Statistics Average Biased 1.79E-02 1.80E-02 1.81E-02 1.83E-02 1.84E-02 1.83E-02 1.82E-02 Std Dev Biased 5.75E-04 5.20E-04 5.23E-04 5.17E-04 5.11E-04 5.40E-04 5.66E-04 Ps90%/90% (+KTL) Biased 1.95E-02 1.95E-02 1.96E-02 1.97E-02 1.98E-02 1.98E-02 1.97E-02 Ps90%/90% (-KTL) Biased 1.63E-02 1.66E-02 1.67E-02 1.68E-02 1.70E-02 1.68E-02 1.66E-02 Un-Biased Statistics Average Un-Biased 1.80E-02 1.81E-02 1.83E-02 1.82E-02 1.84E-02 1.84E-02 1.82E-02 Std Dev Un-Biased 2.66E-04 1.43E-04 2.26E-04 1.84E-04 2.48E-04 1.11E-04 2.35E-04 Ps90%/90% (+KTL) Un-Biased 1.88E-02 1.85E-02 1.89E-02 1.87E-02 1.91E-02 1.87E-02 1.88E-02 Ps90%/90% (-KTL) Un-Biased 1.73E-02 1.77E-02 1.76E-02 1.77E-02 1.77E-02 1.80E-02 1.76E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 138 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.64. Plot of Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 139 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.64. Raw data for Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low1 2 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=0mA 60 70 Device 0 10 20 30 50 557 1.91E-02 1.92E-02 1.94E-02 1.94E-02 1.95E-02 1.92E-02 1.91E-02 563 1.80E-02 1.83E-02 1.84E-02 1.84E-02 1.85E-02 1.85E-02 1.83E-02 564 1.79E-02 1.83E-02 1.87E-02 1.86E-02 1.87E-02 1.85E-02 1.85E-02 567 1.78E-02 1.82E-02 1.85E-02 1.84E-02 1.83E-02 1.84E-02 1.81E-02 569 1.87E-02 1.89E-02 1.90E-02 1.90E-02 1.92E-02 1.92E-02 1.89E-02 570 1.84E-02 1.83E-02 1.86E-02 1.85E-02 1.85E-02 1.86E-02 1.84E-02 571 1.83E-02 1.84E-02 1.87E-02 1.86E-02 1.87E-02 1.86E-02 1.85E-02 572 1.88E-02 1.88E-02 1.89E-02 1.89E-02 1.90E-02 1.91E-02 1.90E-02 573 1.91E-02 1.91E-02 1.94E-02 1.92E-02 1.93E-02 1.93E-02 1.90E-02 574 1.88E-02 1.88E-02 1.89E-02 1.91E-02 1.89E-02 1.91E-02 1.89E-02 584 1.83E-02 1.84E-02 1.85E-02 1.85E-02 1.83E-02 1.83E-02 1.82E-02 585 1.84E-02 1.83E-02 1.88E-02 1.87E-02 1.85E-02 1.82E-02 1.83E-02 Biased Statistics Average Biased 1.83E-02 1.86E-02 1.88E-02 1.88E-02 1.88E-02 1.88E-02 1.86E-02 Std Dev Biased 5.54E-04 4.42E-04 4.05E-04 4.15E-04 5.03E-04 4.04E-04 4.29E-04 Ps90%/90% (+KTL) Biased 1.98E-02 1.98E-02 1.99E-02 1.99E-02 2.02E-02 1.99E-02 1.98E-02 Ps90%/90% (-KTL) Biased 1.68E-02 1.74E-02 1.77E-02 1.76E-02 1.74E-02 1.76E-02 1.74E-02 Un-Biased Statistics Average Un-Biased 1.87E-02 1.87E-02 1.89E-02 1.89E-02 1.89E-02 1.89E-02 1.88E-02 Std Dev Un-Biased 3.25E-04 3.45E-04 3.09E-04 3.06E-04 3.20E-04 3.29E-04 2.98E-04 Ps90%/90% (+KTL) Un-Biased 1.96E-02 1.96E-02 1.97E-02 1.97E-02 1.98E-02 1.98E-02 1.96E-02 Ps90%/90% (-KTL) Un-Biased 1.78E-02 1.77E-02 1.80E-02 1.80E-02 1.80E-02 1.80E-02 1.79E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 140 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.65. Plot of Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 141 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.65. Raw data for Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low1 3 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=0mA 60 70 Device 0 10 20 30 50 557 1.89E-02 1.89E-02 1.91E-02 1.93E-02 1.93E-02 1.93E-02 1.90E-02 563 1.77E-02 1.78E-02 1.80E-02 1.81E-02 1.81E-02 1.82E-02 1.78E-02 564 1.79E-02 1.79E-02 1.82E-02 1.84E-02 1.82E-02 1.82E-02 1.82E-02 567 1.74E-02 1.79E-02 1.78E-02 1.78E-02 1.81E-02 1.79E-02 1.78E-02 569 1.86E-02 1.88E-02 1.91E-02 1.90E-02 1.91E-02 1.90E-02 1.90E-02 570 1.76E-02 1.77E-02 1.78E-02 1.79E-02 1.79E-02 1.79E-02 1.78E-02 571 1.83E-02 1.83E-02 1.86E-02 1.85E-02 1.86E-02 1.85E-02 1.84E-02 572 1.82E-02 1.86E-02 1.86E-02 1.84E-02 1.86E-02 1.86E-02 1.84E-02 573 1.83E-02 1.83E-02 1.85E-02 1.87E-02 1.86E-02 1.86E-02 1.84E-02 574 1.86E-02 1.86E-02 1.88E-02 1.89E-02 1.89E-02 1.90E-02 1.87E-02 584 1.81E-02 1.81E-02 1.82E-02 1.81E-02 1.79E-02 1.79E-02 1.78E-02 585 1.81E-02 1.82E-02 1.87E-02 1.83E-02 1.83E-02 1.80E-02 1.81E-02 Biased Statistics Average Biased 1.81E-02 1.83E-02 1.84E-02 1.85E-02 1.86E-02 1.85E-02 1.84E-02 Std Dev Biased 6.13E-04 5.54E-04 6.04E-04 6.17E-04 6.06E-04 5.94E-04 6.09E-04 Ps90%/90% (+KTL) Biased 1.98E-02 1.98E-02 2.01E-02 2.02E-02 2.02E-02 2.02E-02 2.00E-02 Ps90%/90% (-KTL) Biased 1.64E-02 1.67E-02 1.68E-02 1.68E-02 1.69E-02 1.69E-02 1.67E-02 Un-Biased Statistics Average Un-Biased 1.82E-02 1.83E-02 1.85E-02 1.85E-02 1.85E-02 1.85E-02 1.83E-02 Std Dev Un-Biased 3.62E-04 3.78E-04 4.03E-04 3.88E-04 3.85E-04 4.03E-04 3.47E-04 Ps90%/90% (+KTL) Un-Biased 1.92E-02 1.93E-02 1.96E-02 1.95E-02 1.96E-02 1.96E-02 1.93E-02 Ps90%/90% (-KTL) Un-Biased 1.72E-02 1.72E-02 1.74E-02 1.74E-02 1.74E-02 1.74E-02 1.74E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 142 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.66. Plot of Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 143 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.66. Raw data for Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low1 4 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=0mA 60 70 Device 0 10 20 30 50 557 1.90E-02 1.91E-02 1.95E-02 1.92E-02 1.94E-02 1.93E-02 1.92E-02 563 1.81E-02 1.82E-02 1.83E-02 1.85E-02 1.85E-02 1.85E-02 1.83E-02 564 1.81E-02 1.83E-02 1.84E-02 1.87E-02 1.85E-02 1.85E-02 1.82E-02 567 1.78E-02 1.81E-02 1.82E-02 1.81E-02 1.83E-02 1.83E-02 1.81E-02 569 1.80E-02 1.83E-02 1.84E-02 1.83E-02 1.83E-02 1.81E-02 1.83E-02 570 1.84E-02 1.84E-02 1.84E-02 1.85E-02 1.85E-02 1.85E-02 1.84E-02 571 1.85E-02 1.86E-02 1.88E-02 1.87E-02 1.88E-02 1.87E-02 1.85E-02 572 1.84E-02 1.84E-02 1.84E-02 1.84E-02 1.88E-02 1.86E-02 1.85E-02 573 1.84E-02 1.85E-02 1.86E-02 1.87E-02 1.87E-02 1.87E-02 1.86E-02 574 1.82E-02 1.83E-02 1.84E-02 1.85E-02 1.85E-02 1.85E-02 1.83E-02 584 1.88E-02 1.89E-02 1.90E-02 1.90E-02 1.88E-02 1.88E-02 1.89E-02 585 1.89E-02 1.89E-02 1.93E-02 1.89E-02 1.88E-02 1.88E-02 1.87E-02 Biased Statistics Average Biased 1.82E-02 1.84E-02 1.85E-02 1.86E-02 1.86E-02 1.85E-02 1.84E-02 Std Dev Biased 4.83E-04 4.23E-04 5.15E-04 3.95E-04 4.54E-04 4.69E-04 4.65E-04 Ps90%/90% (+KTL) Biased 1.95E-02 1.96E-02 2.00E-02 1.97E-02 1.99E-02 1.98E-02 1.97E-02 Ps90%/90% (-KTL) Biased 1.69E-02 1.72E-02 1.71E-02 1.75E-02 1.74E-02 1.73E-02 1.71E-02 Un-Biased Statistics Average Un-Biased 1.84E-02 1.84E-02 1.85E-02 1.86E-02 1.87E-02 1.86E-02 1.85E-02 Std Dev Un-Biased 1.28E-04 1.18E-04 1.79E-04 1.36E-04 1.35E-04 9.82E-05 1.16E-04 Ps90%/90% (+KTL) Un-Biased 1.87E-02 1.87E-02 1.90E-02 1.89E-02 1.90E-02 1.89E-02 1.88E-02 Ps90%/90% (-KTL) Un-Biased 1.80E-02 1.81E-02 1.80E-02 1.82E-02 1.83E-02 1.83E-02 1.81E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 144 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.67. Plot of Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 145 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.67. Raw data for Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low2 1 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=1mA 60 70 Device 0 10 20 30 50 557 5.24E-02 5.24E-02 5.26E-02 5.26E-02 5.26E-02 5.25E-02 5.26E-02 563 5.19E-02 5.19E-02 5.22E-02 5.23E-02 5.23E-02 5.20E-02 5.19E-02 564 5.18E-02 5.20E-02 5.22E-02 5.24E-02 5.23E-02 5.20E-02 5.22E-02 567 5.16E-02 5.20E-02 5.22E-02 5.22E-02 5.22E-02 5.20E-02 5.17E-02 569 5.17E-02 5.19E-02 5.19E-02 5.20E-02 5.21E-02 5.18E-02 5.18E-02 570 5.18E-02 5.20E-02 5.19E-02 5.21E-02 5.18E-02 5.19E-02 5.17E-02 571 5.23E-02 5.23E-02 5.26E-02 5.26E-02 5.26E-02 5.25E-02 5.22E-02 572 5.25E-02 5.24E-02 5.26E-02 5.25E-02 5.26E-02 5.25E-02 5.25E-02 573 5.23E-02 5.24E-02 5.24E-02 5.27E-02 5.25E-02 5.24E-02 5.22E-02 574 5.22E-02 5.21E-02 5.24E-02 5.22E-02 5.25E-02 5.22E-02 5.21E-02 584 5.25E-02 5.27E-02 5.29E-02 5.26E-02 5.24E-02 5.22E-02 5.22E-02 585 5.22E-02 5.25E-02 5.29E-02 5.25E-02 5.23E-02 5.21E-02 5.22E-02 Biased Statistics Average Biased 5.19E-02 5.20E-02 5.22E-02 5.23E-02 5.23E-02 5.21E-02 5.20E-02 Std Dev Biased 3.27E-04 1.93E-04 2.31E-04 2.35E-04 1.97E-04 2.47E-04 3.60E-04 Ps90%/90% (+KTL) Biased 5.28E-02 5.26E-02 5.29E-02 5.30E-02 5.28E-02 5.27E-02 5.30E-02 Ps90%/90% (-KTL) Biased 5.10E-02 5.15E-02 5.16E-02 5.17E-02 5.17E-02 5.14E-02 5.11E-02 Un-Biased Statistics Average Un-Biased 5.22E-02 5.22E-02 5.24E-02 5.24E-02 5.24E-02 5.23E-02 5.21E-02 Std Dev Un-Biased 2.82E-04 1.95E-04 2.92E-04 2.59E-04 3.51E-04 2.58E-04 2.65E-04 Ps90%/90% (+KTL) Un-Biased 5.30E-02 5.28E-02 5.32E-02 5.32E-02 5.33E-02 5.30E-02 5.29E-02 Ps90%/90% (-KTL) Un-Biased 5.14E-02 5.17E-02 5.16E-02 5.17E-02 5.14E-02 5.16E-02 5.14E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 146 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.68. Plot of Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 147 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.68. Raw data for Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low2 2 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=1mA 60 70 Device 0 10 20 30 50 557 5.23E-02 5.24E-02 5.23E-02 5.25E-02 5.25E-02 5.23E-02 5.25E-02 563 5.25E-02 5.25E-02 5.28E-02 5.30E-02 5.29E-02 5.25E-02 5.28E-02 564 5.27E-02 5.30E-02 5.31E-02 5.35E-02 5.32E-02 5.27E-02 5.30E-02 567 5.27E-02 5.29E-02 5.30E-02 5.30E-02 5.31E-02 5.29E-02 5.28E-02 569 5.28E-02 5.32E-02 5.33E-02 5.31E-02 5.31E-02 5.30E-02 5.31E-02 570 5.27E-02 5.31E-02 5.30E-02 5.29E-02 5.29E-02 5.31E-02 5.27E-02 571 5.26E-02 5.27E-02 5.30E-02 5.29E-02 5.28E-02 5.26E-02 5.24E-02 572 5.27E-02 5.26E-02 5.30E-02 5.27E-02 5.28E-02 5.25E-02 5.26E-02 573 5.39E-02 5.39E-02 5.41E-02 5.41E-02 5.40E-02 5.38E-02 5.37E-02 574 5.22E-02 5.23E-02 5.25E-02 5.26E-02 5.25E-02 5.22E-02 5.24E-02 584 5.26E-02 5.28E-02 5.27E-02 5.28E-02 5.25E-02 5.24E-02 5.24E-02 585 5.26E-02 5.28E-02 5.32E-02 5.30E-02 5.30E-02 5.26E-02 5.25E-02 Biased Statistics Average Biased 5.26E-02 5.28E-02 5.29E-02 5.30E-02 5.29E-02 5.27E-02 5.28E-02 Std Dev Biased 2.26E-04 3.30E-04 3.57E-04 3.51E-04 2.61E-04 2.91E-04 2.55E-04 Ps90%/90% (+KTL) Biased 5.32E-02 5.37E-02 5.39E-02 5.40E-02 5.37E-02 5.35E-02 5.35E-02 Ps90%/90% (-KTL) Biased 5.20E-02 5.19E-02 5.19E-02 5.20E-02 5.22E-02 5.19E-02 5.21E-02 Un-Biased Statistics Average Un-Biased 5.28E-02 5.29E-02 5.31E-02 5.30E-02 5.30E-02 5.28E-02 5.27E-02 Std Dev Un-Biased 6.33E-04 6.28E-04 5.71E-04 6.09E-04 5.76E-04 6.09E-04 5.30E-04 Ps90%/90% (+KTL) Un-Biased 5.45E-02 5.46E-02 5.47E-02 5.47E-02 5.46E-02 5.45E-02 5.42E-02 Ps90%/90% (-KTL) Un-Biased 5.11E-02 5.12E-02 5.15E-02 5.14E-02 5.14E-02 5.12E-02 5.13E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 148 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.69. Plot of Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 149 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.69. Raw data for Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low2 3 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=1mA 60 70 Device 0 10 20 30 50 557 5.18E-02 5.20E-02 5.21E-02 5.21E-02 5.22E-02 5.20E-02 5.19E-02 563 5.20E-02 5.20E-02 5.23E-02 5.25E-02 5.23E-02 5.23E-02 5.22E-02 564 5.21E-02 5.22E-02 5.24E-02 5.27E-02 5.25E-02 5.24E-02 5.23E-02 567 5.17E-02 5.22E-02 5.24E-02 5.25E-02 5.23E-02 5.23E-02 5.22E-02 569 5.27E-02 5.30E-02 5.31E-02 5.31E-02 5.29E-02 5.30E-02 5.30E-02 570 5.18E-02 5.18E-02 5.20E-02 5.19E-02 5.20E-02 5.20E-02 5.17E-02 571 5.23E-02 5.23E-02 5.25E-02 5.27E-02 5.26E-02 5.25E-02 5.24E-02 572 5.20E-02 5.22E-02 5.22E-02 5.23E-02 5.23E-02 5.21E-02 5.23E-02 573 5.27E-02 5.28E-02 5.31E-02 5.30E-02 5.30E-02 5.29E-02 5.27E-02 574 5.20E-02 5.21E-02 5.24E-02 5.23E-02 5.22E-02 5.22E-02 5.21E-02 584 5.19E-02 5.20E-02 5.22E-02 5.22E-02 5.19E-02 5.16E-02 5.17E-02 585 5.22E-02 5.22E-02 5.30E-02 5.26E-02 5.24E-02 5.20E-02 5.22E-02 Biased Statistics Average Biased 5.21E-02 5.23E-02 5.25E-02 5.26E-02 5.24E-02 5.24E-02 5.23E-02 Std Dev Biased 4.08E-04 4.24E-04 3.55E-04 3.42E-04 2.78E-04 3.66E-04 3.87E-04 Ps90%/90% (+KTL) Biased 5.32E-02 5.34E-02 5.34E-02 5.35E-02 5.32E-02 5.34E-02 5.34E-02 Ps90%/90% (-KTL) Biased 5.09E-02 5.11E-02 5.15E-02 5.16E-02 5.17E-02 5.14E-02 5.12E-02 Un-Biased Statistics Average Un-Biased 5.22E-02 5.22E-02 5.24E-02 5.25E-02 5.24E-02 5.23E-02 5.22E-02 Std Dev Un-Biased 3.48E-04 3.60E-04 3.94E-04 4.24E-04 4.01E-04 3.64E-04 3.58E-04 Ps90%/90% (+KTL) Un-Biased 5.31E-02 5.32E-02 5.35E-02 5.36E-02 5.35E-02 5.33E-02 5.32E-02 Ps90%/90% (-KTL) Un-Biased 5.12E-02 5.12E-02 5.14E-02 5.13E-02 5.13E-02 5.13E-02 5.12E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 150 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.70. Plot of Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 151 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.70. Raw data for Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low2 4 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=1mA 60 70 Device 0 10 20 30 50 557 5.26E-02 5.26E-02 5.27E-02 5.30E-02 5.29E-02 5.27E-02 5.26E-02 563 5.24E-02 5.24E-02 5.26E-02 5.29E-02 5.27E-02 5.26E-02 5.27E-02 564 5.24E-02 5.27E-02 5.30E-02 5.30E-02 5.28E-02 5.26E-02 5.27E-02 567 5.23E-02 5.25E-02 5.27E-02 5.27E-02 5.27E-02 5.26E-02 5.23E-02 569 5.21E-02 5.25E-02 5.25E-02 5.25E-02 5.24E-02 5.23E-02 5.24E-02 570 5.28E-02 5.28E-02 5.30E-02 5.28E-02 5.27E-02 5.28E-02 5.26E-02 571 5.30E-02 5.28E-02 5.33E-02 5.32E-02 5.31E-02 5.31E-02 5.30E-02 572 5.29E-02 5.28E-02 5.31E-02 5.32E-02 5.31E-02 5.28E-02 5.29E-02 573 5.32E-02 5.31E-02 5.34E-02 5.33E-02 5.32E-02 5.33E-02 5.31E-02 574 5.25E-02 5.25E-02 5.27E-02 5.27E-02 5.26E-02 5.25E-02 5.25E-02 584 5.28E-02 5.29E-02 5.30E-02 5.29E-02 5.27E-02 5.25E-02 5.26E-02 585 5.28E-02 5.29E-02 5.34E-02 5.30E-02 5.30E-02 5.25E-02 5.27E-02 Biased Statistics Average Biased 5.23E-02 5.25E-02 5.27E-02 5.28E-02 5.27E-02 5.26E-02 5.25E-02 Std Dev Biased 1.66E-04 9.43E-05 1.89E-04 2.18E-04 1.78E-04 1.44E-04 1.88E-04 Ps90%/90% (+KTL) Biased 5.28E-02 5.28E-02 5.32E-02 5.34E-02 5.32E-02 5.30E-02 5.30E-02 Ps90%/90% (-KTL) Biased 5.19E-02 5.23E-02 5.22E-02 5.22E-02 5.22E-02 5.22E-02 5.20E-02 Un-Biased Statistics Average Un-Biased 5.29E-02 5.28E-02 5.31E-02 5.30E-02 5.29E-02 5.29E-02 5.28E-02 Std Dev Un-Biased 2.54E-04 2.18E-04 2.70E-04 2.75E-04 2.60E-04 2.94E-04 2.50E-04 Ps90%/90% (+KTL) Un-Biased 5.36E-02 5.34E-02 5.38E-02 5.38E-02 5.36E-02 5.37E-02 5.35E-02 Ps90%/90% (-KTL) Un-Biased 5.22E-02 5.22E-02 5.23E-02 5.23E-02 5.22E-02 5.21E-02 5.21E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 152 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.71. Plot of Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 153 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.71. Raw data for Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low3 1 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=10mA 60 70 Device 0 10 20 30 50 557 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.16E-01 2.16E-01 563 2.19E-01 2.18E-01 2.19E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01 564 2.20E-01 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.20E-01 2.21E-01 567 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01 2.20E-01 569 2.18E-01 2.19E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01 2.18E-01 570 2.18E-01 2.18E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01 2.17E-01 571 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.19E-01 2.19E-01 572 2.22E-01 2.21E-01 2.22E-01 2.22E-01 2.21E-01 2.21E-01 2.21E-01 573 2.20E-01 2.20E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01 2.20E-01 574 2.18E-01 2.18E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01 2.18E-01 584 2.17E-01 2.18E-01 2.18E-01 2.18E-01 2.17E-01 2.16E-01 2.17E-01 585 2.18E-01 2.19E-01 2.20E-01 2.19E-01 2.19E-01 2.17E-01 2.18E-01 Biased Statistics Average Biased 2.19E-01 2.19E-01 2.19E-01 2.20E-01 2.19E-01 2.18E-01 2.19E-01 Std Dev Biased 1.47E-03 1.78E-03 1.64E-03 1.82E-03 1.68E-03 1.60E-03 1.66E-03 Ps90%/90% (+KTL) Biased 2.23E-01 2.24E-01 2.24E-01 2.25E-01 2.24E-01 2.23E-01 2.23E-01 Ps90%/90% (-KTL) Biased 2.15E-01 2.14E-01 2.15E-01 2.15E-01 2.14E-01 2.14E-01 2.14E-01 Un-Biased Statistics Average Un-Biased 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.19E-01 2.19E-01 2.19E-01 Std Dev Un-Biased 1.45E-03 1.36E-03 1.20E-03 1.35E-03 1.34E-03 1.26E-03 1.43E-03 Ps90%/90% (+KTL) Un-Biased 2.24E-01 2.23E-01 2.23E-01 2.24E-01 2.23E-01 2.22E-01 2.23E-01 Ps90%/90% (-KTL) Un-Biased 2.16E-01 2.16E-01 2.17E-01 2.16E-01 2.16E-01 2.15E-01 2.15E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 154 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.72. Plot of Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 155 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.72. Raw data for Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low3 2 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=10mA 60 70 Device 0 10 20 30 50 557 2.16E-01 2.16E-01 2.17E-01 2.17E-01 2.17E-01 2.16E-01 2.16E-01 563 2.24E-01 2.23E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01 2.24E-01 564 2.23E-01 2.24E-01 2.24E-01 2.25E-01 2.24E-01 2.23E-01 2.24E-01 567 2.22E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01 2.23E-01 2.23E-01 569 2.22E-01 2.23E-01 2.23E-01 2.23E-01 2.22E-01 2.21E-01 2.22E-01 570 2.23E-01 2.23E-01 2.23E-01 2.23E-01 2.22E-01 2.22E-01 2.22E-01 571 2.21E-01 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01 572 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.19E-01 2.19E-01 2.19E-01 573 2.24E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01 2.23E-01 2.23E-01 574 2.19E-01 2.18E-01 2.19E-01 2.20E-01 2.19E-01 2.18E-01 2.18E-01 584 2.23E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01 2.22E-01 2.23E-01 585 2.23E-01 2.23E-01 2.25E-01 2.24E-01 2.24E-01 2.22E-01 2.22E-01 Biased Statistics Average Biased 2.22E-01 2.22E-01 2.22E-01 2.23E-01 2.22E-01 2.21E-01 2.22E-01 Std Dev Biased 2.92E-03 3.30E-03 3.08E-03 3.21E-03 3.13E-03 2.96E-03 3.23E-03 Ps90%/90% (+KTL) Biased 2.30E-01 2.31E-01 2.31E-01 2.31E-01 2.31E-01 2.29E-01 2.31E-01 Ps90%/90% (-KTL) Biased 2.14E-01 2.13E-01 2.14E-01 2.14E-01 2.13E-01 2.13E-01 2.13E-01 Un-Biased Statistics Average Un-Biased 2.21E-01 2.21E-01 2.22E-01 2.22E-01 2.21E-01 2.20E-01 2.20E-01 Std Dev Un-Biased 2.03E-03 2.25E-03 2.01E-03 1.95E-03 2.00E-03 2.09E-03 2.03E-03 Ps90%/90% (+KTL) Un-Biased 2.27E-01 2.27E-01 2.27E-01 2.27E-01 2.26E-01 2.26E-01 2.26E-01 Ps90%/90% (-KTL) Un-Biased 2.16E-01 2.15E-01 2.16E-01 2.16E-01 2.15E-01 2.15E-01 2.15E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 156 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.73. Plot of Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 157 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.73. Raw data for Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low3 3 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=10mA 60 70 Device 0 10 20 30 50 557 2.14E-01 2.15E-01 2.15E-01 2.15E-01 2.15E-01 2.14E-01 2.14E-01 563 2.21E-01 2.22E-01 2.21E-01 2.22E-01 2.21E-01 2.20E-01 2.21E-01 564 2.21E-01 2.22E-01 2.22E-01 2.22E-01 2.22E-01 2.21E-01 2.22E-01 567 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01 569 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01 2.20E-01 570 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.19E-01 2.19E-01 2.19E-01 571 2.19E-01 2.19E-01 2.19E-01 2.20E-01 2.20E-01 2.18E-01 2.18E-01 572 2.18E-01 2.17E-01 2.18E-01 2.18E-01 2.17E-01 2.16E-01 2.17E-01 573 2.20E-01 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.21E-01 2.20E-01 574 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.16E-01 2.16E-01 584 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.19E-01 2.19E-01 585 2.20E-01 2.20E-01 2.22E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01 Biased Statistics Average Biased 2.19E-01 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.19E-01 2.19E-01 Std Dev Biased 2.88E-03 3.00E-03 3.02E-03 3.19E-03 2.92E-03 2.96E-03 3.16E-03 Ps90%/90% (+KTL) Biased 2.27E-01 2.28E-01 2.28E-01 2.29E-01 2.28E-01 2.27E-01 2.28E-01 Ps90%/90% (-KTL) Biased 2.11E-01 2.12E-01 2.12E-01 2.11E-01 2.12E-01 2.11E-01 2.11E-01 Un-Biased Statistics Average Un-Biased 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01 Std Dev Un-Biased 1.52E-03 1.67E-03 1.59E-03 1.74E-03 1.65E-03 1.82E-03 1.53E-03 Ps90%/90% (+KTL) Un-Biased 2.23E-01 2.23E-01 2.24E-01 2.24E-01 2.23E-01 2.23E-01 2.22E-01 Ps90%/90% (-KTL) Un-Biased 2.14E-01 2.14E-01 2.15E-01 2.14E-01 2.14E-01 2.13E-01 2.14E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 158 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.74. Plot of Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 159 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.74. Raw data for Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low3 4 15V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+/-15V IL=10mA 60 70 Device 0 10 20 30 50 557 2.19E-01 2.18E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01 2.18E-01 563 2.21E-01 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.21E-01 2.21E-01 564 2.22E-01 2.23E-01 2.24E-01 2.24E-01 2.23E-01 2.22E-01 2.23E-01 567 2.22E-01 2.24E-01 2.23E-01 2.24E-01 2.23E-01 2.22E-01 2.23E-01 569 2.21E-01 2.22E-01 2.22E-01 2.22E-01 2.21E-01 2.21E-01 2.21E-01 570 2.22E-01 2.22E-01 2.22E-01 2.22E-01 2.21E-01 2.21E-01 2.21E-01 571 2.22E-01 2.22E-01 2.23E-01 2.23E-01 2.22E-01 2.21E-01 2.22E-01 572 2.24E-01 2.24E-01 2.25E-01 2.24E-01 2.24E-01 2.23E-01 2.24E-01 573 2.23E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01 2.22E-01 2.22E-01 574 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.21E-01 2.20E-01 2.21E-01 584 2.19E-01 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.18E-01 2.19E-01 585 2.21E-01 2.21E-01 2.23E-01 2.22E-01 2.21E-01 2.20E-01 2.21E-01 Biased Statistics Average Biased 2.21E-01 2.22E-01 2.22E-01 2.22E-01 2.21E-01 2.21E-01 2.21E-01 Std Dev Biased 1.58E-03 2.07E-03 1.95E-03 2.03E-03 2.14E-03 1.67E-03 1.98E-03 Ps90%/90% (+KTL) Biased 2.25E-01 2.27E-01 2.27E-01 2.28E-01 2.27E-01 2.25E-01 2.27E-01 Ps90%/90% (-KTL) Biased 2.17E-01 2.16E-01 2.16E-01 2.17E-01 2.16E-01 2.16E-01 2.16E-01 Un-Biased Statistics Average Un-Biased 2.23E-01 2.23E-01 2.23E-01 2.23E-01 2.22E-01 2.22E-01 2.22E-01 Std Dev Un-Biased 1.26E-03 1.34E-03 1.20E-03 1.30E-03 1.29E-03 1.04E-03 1.17E-03 Ps90%/90% (+KTL) Un-Biased 2.26E-01 2.26E-01 2.26E-01 2.26E-01 2.26E-01 2.24E-01 2.25E-01 Ps90%/90% (-KTL) Un-Biased 2.19E-01 2.19E-01 2.20E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 160 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ 1.50E+04 1.00E+04 5.00E+03 0.00E+00 -5.00E+03 -1.00E+04 -1.50E+04 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.75. Plot of Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 161 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.75. Raw data for Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Total Dose (krad(Si)) 20 30 9.89E+03 9.65E+03 6.69E+03 6.25E+03 6.56E+03 6.24E+03 6.79E+03 6.07E+03 1.81E+04 1.39E+04 6.31E+03 5.93E+03 1.14E+04 9.22E+03 6.15E+03 7.49E+03 2.40E+04 2.30E+04 1.56E+04 1.33E+04 3.34E+04 2.94E+04 5.80E+03 5.69E+03 50 8.97E+03 7.06E+03 6.21E+03 6.14E+03 1.78E+04 6.41E+03 9.67E+03 7.14E+03 1.89E+04 1.33E+04 5.68E+04 6.68E+03 24 Hr Anneal 60 9.92E+03 7.83E+03 6.98E+03 6.59E+03 2.22E+04 6.36E+03 1.04E+04 6.55E+03 2.45E+04 1.78E+04 5.24E+04 6.60E+03 168 Hr Anneal 70 9.10E+03 7.06E+03 6.78E+03 6.55E+03 1.83E+04 6.62E+03 1.15E+04 5.88E+03 2.13E+04 1.52E+04 3.33E+04 5.94E+03 0 9.12E+03 6.54E+03 6.24E+03 6.32E+03 1.56E+04 6.24E+03 1.00E+04 6.19E+03 2.04E+04 1.41E+04 2.53E+04 5.76E+03 10 1.06E+04 6.82E+03 6.63E+03 6.43E+03 1.51E+04 6.06E+03 1.15E+04 5.81E+03 2.69E+04 1.71E+04 3.30E+04 5.98E+03 8.75E+03 3.99E+03 1.97E+04 -2.18E+03 9.11E+03 3.76E+03 1.94E+04 -1.19E+03 9.60E+03 4.93E+03 2.31E+04 -3.92E+03 8.42E+03 3.41E+03 1.78E+04 -9.37E+02 9.24E+03 4.94E+03 2.28E+04 -4.30E+03 1.07E+04 6.55E+03 2.87E+04 -7.26E+03 9.55E+03 4.98E+03 2.32E+04 -4.10E+03 1.14E+04 6.01E+03 2.79E+04 -5.08E+03 1.00E+03 PASS 1.35E+04 8.84E+03 3.77E+04 -1.07E+04 5.00E+02 PASS 1.27E+04 7.42E+03 3.30E+04 -7.67E+03 5.00E+02 PASS 1.18E+04 6.83E+03 3.05E+04 -6.95E+03 5.00E+02 PASS 1.11E+04 5.15E+03 2.52E+04 -3.02E+03 5.00E+02 PASS 1.31E+04 7.85E+03 3.46E+04 -8.40E+03 5.00E+02 PASS 1.21E+04 6.39E+03 2.96E+04 -5.40E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 162 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ 7.00E+03 6.00E+03 5.00E+03 4.00E+03 3.00E+03 2.00E+03 1.00E+03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.76. Plot of Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 163 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.76. Raw data for Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 3.82E+03 5.75E+03 5.77E+03 5.53E+03 3.55E+03 6.10E+03 6.36E+03 4.54E+03 6.17E+03 6.39E+03 3.70E+03 3.68E+03 24 Hr Anneal 60 3.48E+03 5.84E+03 6.08E+03 5.58E+03 3.61E+03 6.06E+03 5.92E+03 4.33E+03 6.19E+03 6.45E+03 3.34E+03 3.65E+03 168 Hr Anneal 70 3.59E+03 5.82E+03 5.97E+03 6.03E+03 3.60E+03 5.93E+03 6.21E+03 4.36E+03 6.08E+03 6.56E+03 3.67E+03 3.64E+03 0 3.74E+03 6.62E+03 5.82E+03 6.52E+03 3.82E+03 6.54E+03 6.62E+03 4.74E+03 6.88E+03 6.80E+03 5.55E+03 3.74E+03 10 3.70E+03 5.95E+03 6.18E+03 6.73E+03 3.65E+03 6.49E+03 6.90E+03 4.48E+03 6.51E+03 6.91E+03 3.70E+03 3.67E+03 Total Dose (krad(Si)) 20 30 3.67E+03 3.68E+03 6.01E+03 5.87E+03 6.19E+03 5.92E+03 5.99E+03 5.88E+03 3.75E+03 3.74E+03 6.46E+03 6.29E+03 6.24E+03 6.33E+03 4.64E+03 4.43E+03 6.37E+03 6.44E+03 6.58E+03 6.76E+03 3.71E+03 3.71E+03 3.66E+03 3.65E+03 5.30E+03 1.42E+03 9.21E+03 1.40E+03 5.24E+03 1.46E+03 9.23E+03 1.25E+03 5.12E+03 1.29E+03 8.66E+03 1.58E+03 5.02E+03 1.20E+03 8.30E+03 1.74E+03 4.88E+03 1.10E+03 7.91E+03 1.86E+03 4.92E+03 1.27E+03 8.39E+03 1.44E+03 5.00E+03 1.29E+03 8.53E+03 1.47E+03 6.31E+03 8.90E+02 8.75E+03 3.87E+03 1.00E+03 PASS 6.26E+03 1.02E+03 9.05E+03 3.47E+03 5.00E+02 PASS 6.06E+03 8.03E+02 8.26E+03 3.85E+03 5.00E+02 PASS 6.05E+03 9.26E+02 8.59E+03 3.51E+03 5.00E+02 PASS 5.91E+03 7.78E+02 8.05E+03 3.78E+03 5.00E+02 PASS 5.79E+03 8.41E+02 8.10E+03 3.48E+03 5.00E+02 PASS 5.83E+03 8.53E+02 8.17E+03 3.49E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 164 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ 6.00E+03 5.00E+03 4.00E+03 3.00E+03 2.00E+03 1.00E+03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.77. Plot of Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 165 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.77. Raw data for Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 3.54E+03 3.41E+03 3.65E+03 4.59E+03 5.46E+03 3.63E+03 3.48E+03 3.68E+03 3.62E+03 5.21E+03 6.31E+03 3.68E+03 24 Hr Anneal 60 3.42E+03 3.33E+03 3.61E+03 4.51E+03 5.46E+03 3.83E+03 3.84E+03 3.71E+03 3.81E+03 5.29E+03 6.19E+03 3.74E+03 168 Hr Anneal 70 3.52E+03 3.51E+03 3.89E+03 4.82E+03 5.82E+03 3.73E+03 3.85E+03 3.78E+03 3.81E+03 5.52E+03 6.06E+03 3.76E+03 0 3.99E+03 4.02E+03 4.44E+03 5.70E+03 7.09E+03 4.20E+03 4.15E+03 4.22E+03 4.18E+03 6.30E+03 7.16E+03 4.00E+03 10 3.67E+03 3.55E+03 4.06E+03 5.02E+03 6.03E+03 3.78E+03 3.91E+03 3.78E+03 3.97E+03 5.65E+03 6.34E+03 3.82E+03 Total Dose (krad(Si)) 20 30 3.65E+03 3.65E+03 3.39E+03 3.56E+03 3.91E+03 3.85E+03 4.88E+03 4.83E+03 5.90E+03 6.11E+03 3.83E+03 3.93E+03 3.68E+03 3.81E+03 3.88E+03 3.81E+03 3.95E+03 3.84E+03 5.74E+03 5.13E+03 6.31E+03 6.23E+03 3.84E+03 3.78E+03 5.05E+03 1.34E+03 8.71E+03 1.38E+03 4.46E+03 1.05E+03 7.34E+03 1.59E+03 4.34E+03 1.03E+03 7.18E+03 1.51E+03 4.40E+03 1.08E+03 7.36E+03 1.44E+03 4.13E+03 8.76E+02 6.53E+03 1.73E+03 4.07E+03 9.08E+02 6.56E+03 1.58E+03 4.31E+03 9.96E+02 7.04E+03 1.58E+03 4.61E+03 9.46E+02 7.20E+03 2.02E+03 1.00E+03 PASS 4.22E+03 8.06E+02 6.43E+03 2.01E+03 5.00E+02 PASS 4.22E+03 8.60E+02 6.57E+03 1.86E+03 5.00E+02 PASS 4.10E+03 5.75E+02 5.68E+03 2.53E+03 5.00E+02 PASS 3.92E+03 7.21E+02 5.90E+03 1.95E+03 5.00E+02 PASS 4.10E+03 6.70E+02 5.93E+03 2.26E+03 5.00E+02 PASS 4.14E+03 7.73E+02 6.26E+03 2.02E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 166 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ 8.00E+03 7.00E+03 6.00E+03 5.00E+03 4.00E+03 3.00E+03 2.00E+03 1.00E+03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.78. Plot of Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 167 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.78. Raw data for Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 6.37E+03 6.97E+03 4.50E+03 7.15E+03 6.55E+03 6.71E+03 3.95E+03 6.51E+03 4.15E+03 6.18E+03 4.48E+03 4.09E+03 24 Hr Anneal 60 6.81E+03 6.92E+03 4.22E+03 6.69E+03 6.93E+03 6.77E+03 3.88E+03 7.15E+03 3.93E+03 6.16E+03 4.46E+03 4.18E+03 168 Hr Anneal 70 6.41E+03 6.59E+03 4.17E+03 6.98E+03 6.64E+03 6.69E+03 4.08E+03 6.10E+03 4.09E+03 6.36E+03 4.44E+03 3.97E+03 0 7.10E+03 7.76E+03 4.39E+03 7.41E+03 7.41E+03 6.90E+03 4.24E+03 7.34E+03 4.17E+03 6.64E+03 4.56E+03 4.03E+03 10 6.78E+03 7.29E+03 4.34E+03 7.05E+03 6.88E+03 6.96E+03 4.34E+03 7.22E+03 4.08E+03 6.91E+03 4.32E+03 3.99E+03 Total Dose (krad(Si)) 20 30 6.71E+03 7.09E+03 7.61E+03 7.14E+03 4.31E+03 4.04E+03 7.21E+03 6.61E+03 6.86E+03 6.63E+03 6.58E+03 6.54E+03 4.15E+03 4.07E+03 6.20E+03 6.56E+03 4.13E+03 4.03E+03 6.49E+03 6.71E+03 4.32E+03 4.42E+03 3.99E+03 3.95E+03 6.81E+03 1.38E+03 1.06E+04 3.04E+03 6.47E+03 1.21E+03 9.77E+03 3.16E+03 6.54E+03 1.29E+03 1.01E+04 2.99E+03 6.30E+03 1.29E+03 9.83E+03 2.77E+03 6.31E+03 1.06E+03 9.21E+03 3.40E+03 6.31E+03 1.17E+03 9.53E+03 3.10E+03 6.16E+03 1.13E+03 9.26E+03 3.06E+03 5.86E+03 1.53E+03 1.01E+04 1.66E+03 1.00E+03 PASS 5.90E+03 1.55E+03 1.02E+04 1.65E+03 5.00E+02 PASS 5.51E+03 1.26E+03 8.96E+03 2.05E+03 5.00E+02 PASS 5.58E+03 1.40E+03 9.42E+03 1.75E+03 5.00E+02 PASS 5.50E+03 1.34E+03 9.17E+03 1.83E+03 5.00E+02 PASS 5.58E+03 1.57E+03 9.88E+03 1.28E+03 5.00E+02 PASS 5.46E+03 1.28E+03 8.97E+03 1.96E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 168 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 -1.00E+03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.79. Plot of Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 169 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.79. Raw data for Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Total Dose (krad(Si)) 20 30 1.50E+03 1.46E+03 1.10E+03 1.08E+03 1.12E+03 1.11E+03 1.09E+03 1.08E+03 2.46E+03 2.46E+03 1.09E+03 1.09E+03 1.62E+03 1.59E+03 9.94E+02 9.68E+02 2.81E+03 2.65E+03 2.69E+03 2.53E+03 3.15E+03 3.09E+03 1.01E+03 1.01E+03 50 1.47E+03 1.08E+03 1.10E+03 1.10E+03 2.56E+03 1.07E+03 1.57E+03 9.75E+02 2.76E+03 2.56E+03 3.39E+03 1.04E+03 24 Hr Anneal 60 1.46E+03 1.09E+03 1.11E+03 1.10E+03 2.59E+03 1.08E+03 1.63E+03 1.03E+03 2.74E+03 2.62E+03 3.19E+03 1.04E+03 168 Hr Anneal 70 1.49E+03 1.10E+03 1.12E+03 1.10E+03 2.56E+03 1.09E+03 1.61E+03 1.03E+03 2.74E+03 2.60E+03 3.16E+03 1.01E+03 0 1.50E+03 1.11E+03 1.12E+03 1.12E+03 2.63E+03 1.08E+03 1.60E+03 1.08E+03 2.77E+03 2.58E+03 3.02E+03 1.00E+03 10 1.51E+03 1.10E+03 1.11E+03 1.11E+03 2.67E+03 1.10E+03 1.63E+03 1.01E+03 2.86E+03 2.73E+03 3.09E+03 1.01E+03 1.50E+03 6.57E+02 3.30E+03 -3.05E+02 1.50E+03 6.75E+02 3.35E+03 -3.50E+02 1.45E+03 5.91E+02 3.07E+03 -1.66E+02 1.44E+03 5.92E+02 3.06E+03 -1.89E+02 1.46E+03 6.35E+02 3.20E+03 -2.80E+02 1.47E+03 6.45E+02 3.24E+03 -2.98E+02 1.47E+03 6.30E+02 3.20E+03 -2.52E+02 1.82E+03 8.09E+02 4.04E+03 -3.95E+02 5.00E+02 PASS 1.87E+03 8.82E+02 4.28E+03 -5.54E+02 2.50E+02 PASS 1.84E+03 8.63E+02 4.21E+03 -5.29E+02 2.50E+02 PASS 1.77E+03 7.88E+02 3.93E+03 -3.95E+02 2.50E+02 PASS 1.79E+03 8.28E+02 4.06E+03 -4.85E+02 2.50E+02 PASS 1.82E+03 8.22E+02 4.07E+03 -4.32E+02 2.50E+02 PASS 1.81E+03 8.13E+02 4.04E+03 -4.15E+02 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 170 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.80. Plot of Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 171 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.80. Raw data for Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Total Dose (krad(Si)) 20 30 9.60E+02 9.54E+02 2.08E+03 2.10E+03 2.12E+03 1.98E+03 2.23E+03 2.07E+03 9.33E+02 9.33E+02 2.31E+03 2.22E+03 2.28E+03 2.48E+03 1.31E+03 1.30E+03 2.34E+03 2.30E+03 2.30E+03 2.27E+03 9.61E+02 1.01E+03 9.33E+02 9.41E+02 50 9.28E+02 2.10E+03 2.02E+03 1.97E+03 9.31E+02 2.12E+03 2.19E+03 1.27E+03 2.14E+03 2.16E+03 9.63E+02 9.43E+02 24 Hr Anneal 60 9.44E+02 2.02E+03 2.03E+03 2.03E+03 9.21E+02 2.21E+03 2.10E+03 1.28E+03 2.19E+03 2.18E+03 9.60E+02 9.44E+02 168 Hr Anneal 70 9.45E+02 2.08E+03 2.01E+03 2.07E+03 9.25E+02 2.31E+03 2.17E+03 1.31E+03 2.30E+03 2.28E+03 9.66E+02 9.46E+02 0 9.79E+02 2.20E+03 2.18E+03 2.23E+03 9.55E+02 2.40E+03 2.38E+03 1.34E+03 2.44E+03 2.39E+03 9.64E+02 9.48E+02 10 9.69E+02 2.12E+03 2.16E+03 2.19E+03 9.48E+02 2.33E+03 2.36E+03 1.36E+03 2.36E+03 2.40E+03 9.66E+02 9.40E+02 1.71E+03 6.78E+02 3.57E+03 -1.49E+02 1.68E+03 6.57E+02 3.48E+03 -1.23E+02 1.66E+03 6.58E+02 3.47E+03 -1.39E+02 1.61E+03 6.06E+02 3.27E+03 -5.63E+01 1.59E+03 6.05E+02 3.25E+03 -6.77E+01 1.59E+03 5.97E+02 3.22E+03 -5.06E+01 1.61E+03 6.13E+02 3.29E+03 -7.54E+01 2.19E+03 4.74E+02 3.49E+03 8.89E+02 5.00E+02 PASS 2.16E+03 4.49E+02 3.39E+03 9.30E+02 2.50E+02 PASS 2.11E+03 4.49E+02 3.34E+03 8.79E+02 2.50E+02 PASS 2.11E+03 4.65E+02 3.39E+03 8.36E+02 2.50E+02 PASS 1.98E+03 3.96E+02 3.06E+03 8.93E+02 2.50E+02 PASS 1.99E+03 4.02E+02 3.09E+03 8.91E+02 2.50E+02 PASS 2.07E+03 4.30E+02 3.25E+03 8.91E+02 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 172 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ 1.60E+03 1.40E+03 1.20E+03 1.00E+03 8.00E+02 6.00E+02 4.00E+02 2.00E+02 0.00E+00 -2.00E+02 -4.00E+02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.81. Plot of Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 173 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.81. Raw data for Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Total Dose (krad(Si)) 20 30 9.96E+02 9.70E+02 9.29E+02 9.37E+02 1.07E+03 1.06E+03 1.41E+03 1.44E+03 2.18E+03 2.20E+03 9.96E+02 9.59E+02 9.85E+02 9.88E+02 1.03E+03 1.01E+03 9.93E+02 9.72E+02 2.02E+03 2.06E+03 2.31E+03 2.30E+03 9.65E+02 9.70E+02 50 9.57E+02 9.24E+02 1.03E+03 1.37E+03 2.08E+03 9.71E+02 9.62E+02 1.01E+03 9.59E+02 1.90E+03 2.32E+03 9.71E+02 24 Hr Anneal 60 9.62E+02 9.22E+02 1.04E+03 1.38E+03 2.06E+03 9.81E+02 9.54E+02 9.95E+02 9.52E+02 1.90E+03 2.29E+03 9.62E+02 168 Hr Anneal 70 9.85E+02 9.13E+02 1.04E+03 1.41E+03 2.18E+03 9.77E+02 9.80E+02 1.01E+03 9.77E+02 1.95E+03 2.30E+03 9.70E+02 0 1.03E+03 9.72E+02 1.12E+03 1.54E+03 2.38E+03 1.06E+03 1.03E+03 1.07E+03 1.03E+03 2.17E+03 2.46E+03 9.82E+02 10 1.01E+03 9.41E+02 1.07E+03 1.43E+03 2.21E+03 1.02E+03 1.00E+03 1.04E+03 9.92E+02 2.10E+03 2.32E+03 9.64E+02 1.41E+03 5.86E+02 3.01E+03 -1.99E+02 1.33E+03 5.25E+02 2.77E+03 -1.09E+02 1.32E+03 5.15E+02 2.73E+03 -9.83E+01 1.32E+03 5.31E+02 2.78E+03 -1.34E+02 1.27E+03 4.84E+02 2.60E+03 -5.68E+01 1.27E+03 4.77E+02 2.58E+03 -3.52E+01 1.31E+03 5.25E+02 2.75E+03 -1.34E+02 1.27E+03 5.01E+02 2.65E+03 -1.01E+02 5.00E+02 PASS 1.23E+03 4.84E+02 2.56E+03 -9.82E+01 2.50E+02 PASS 1.20E+03 4.55E+02 2.45E+03 -4.40E+01 2.50E+02 PASS 1.20E+03 4.82E+02 2.52E+03 -1.26E+02 2.50E+02 PASS 1.16E+03 4.16E+02 2.30E+03 2.21E+01 2.50E+02 PASS 1.16E+03 4.17E+02 2.30E+03 1.45E+01 2.50E+02 PASS 1.18E+03 4.32E+02 2.36E+03 -6.84E+00 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 174 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.82. Plot of Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 175 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.82. Raw data for Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 2.20E+03 2.29E+03 1.05E+03 2.28E+03 2.25E+03 2.12E+03 1.01E+03 2.12E+03 9.49E+02 2.05E+03 1.08E+03 9.66E+02 24 Hr Anneal 60 2.24E+03 2.22E+03 1.05E+03 2.24E+03 2.28E+03 2.13E+03 1.01E+03 2.16E+03 9.60E+02 2.01E+03 1.08E+03 9.76E+02 168 Hr Anneal 70 2.27E+03 2.30E+03 1.05E+03 2.29E+03 2.28E+03 2.03E+03 1.02E+03 2.17E+03 9.68E+02 2.03E+03 1.07E+03 9.64E+02 0 2.40E+03 2.53E+03 1.09E+03 2.42E+03 2.49E+03 2.42E+03 1.03E+03 2.36E+03 9.85E+02 2.18E+03 1.08E+03 9.62E+02 10 2.34E+03 2.40E+03 1.06E+03 2.38E+03 2.30E+03 2.29E+03 1.04E+03 2.24E+03 9.91E+02 2.18E+03 1.07E+03 9.62E+02 Total Dose (krad(Si)) 20 30 2.27E+03 2.24E+03 2.39E+03 2.34E+03 1.05E+03 1.05E+03 2.24E+03 2.22E+03 2.33E+03 2.29E+03 2.21E+03 2.15E+03 1.03E+03 1.02E+03 2.29E+03 2.17E+03 9.88E+02 9.59E+02 2.08E+03 2.03E+03 1.07E+03 1.06E+03 9.60E+02 9.64E+02 2.19E+03 6.14E+02 3.87E+03 5.04E+02 2.10E+03 5.81E+02 3.69E+03 5.03E+02 2.06E+03 5.66E+02 3.61E+03 5.03E+02 2.03E+03 5.49E+02 3.53E+03 5.22E+02 2.01E+03 5.38E+02 3.49E+03 5.38E+02 2.01E+03 5.37E+02 3.48E+03 5.34E+02 2.04E+03 5.55E+02 3.56E+03 5.16E+02 1.79E+03 7.24E+02 3.78E+03 -1.91E+02 5.00E+02 PASS 1.75E+03 6.72E+02 3.59E+03 -9.33E+01 2.50E+02 PASS 1.72E+03 6.52E+02 3.51E+03 -6.83E+01 2.50E+02 PASS 1.67E+03 6.19E+02 3.36E+03 -3.06E+01 2.50E+02 PASS 1.65E+03 6.15E+02 3.34E+03 -3.60E+01 2.50E+02 PASS 1.65E+03 6.13E+02 3.33E+03 -2.70E+01 2.50E+02 PASS 1.65E+03 5.98E+02 3.28E+03 5.92E+00 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 176 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.83. Plot of Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 177 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.83. Raw data for Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.00E+02 1.06E+02 1.02E+02 1.25E+02 9.84E+01 1.12E+02 1.03E+02 1.01E+02 1.14E+02 1.08E+02 1.03E+02 1.08E+02 24 Hr Anneal 60 1.00E+02 1.06E+02 1.02E+02 1.24E+02 9.84E+01 1.12E+02 1.03E+02 1.01E+02 1.14E+02 1.07E+02 1.03E+02 1.08E+02 168 Hr Anneal 70 1.01E+02 1.06E+02 1.02E+02 1.24E+02 9.85E+01 1.13E+02 1.03E+02 1.02E+02 1.15E+02 1.07E+02 1.03E+02 1.08E+02 0 1.00E+02 1.06E+02 1.02E+02 1.23E+02 9.85E+01 1.13E+02 1.04E+02 1.02E+02 1.13E+02 1.08E+02 1.04E+02 1.09E+02 10 1.00E+02 1.06E+02 1.02E+02 1.24E+02 9.85E+01 1.13E+02 1.04E+02 1.02E+02 1.13E+02 1.08E+02 1.04E+02 1.08E+02 Total Dose (krad(Si)) 20 30 1.00E+02 1.00E+02 1.06E+02 1.06E+02 1.02E+02 1.02E+02 1.25E+02 1.25E+02 9.85E+01 9.85E+01 1.13E+02 1.13E+02 1.03E+02 1.03E+02 1.02E+02 1.02E+02 1.13E+02 1.13E+02 1.08E+02 1.08E+02 1.04E+02 1.03E+02 1.08E+02 1.08E+02 1.06E+02 1.01E+01 1.34E+02 7.85E+01 1.06E+02 1.05E+01 1.35E+02 7.76E+01 1.06E+02 1.08E+01 1.36E+02 7.68E+01 1.07E+02 1.08E+01 1.36E+02 7.68E+01 1.06E+02 1.06E+01 1.36E+02 7.72E+01 1.06E+02 1.04E+01 1.35E+02 7.76E+01 1.06E+02 1.05E+01 1.35E+02 7.75E+01 1.08E+02 5.13E+00 1.22E+02 9.38E+01 9.00E+01 PASS 1.08E+02 5.20E+00 1.22E+02 9.36E+01 8.60E+01 PASS 1.08E+02 5.22E+00 1.22E+02 9.34E+01 8.60E+01 PASS 1.08E+02 5.29E+00 1.22E+02 9.32E+01 8.60E+01 PASS 1.08E+02 5.53E+00 1.23E+02 9.25E+01 8.60E+01 PASS 1.08E+02 5.55E+00 1.23E+02 9.24E+01 8.60E+01 PASS 1.08E+02 5.97E+00 1.24E+02 9.16E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 178 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.84. Plot of Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 179 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.84. Raw data for Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 9.97E+01 1.07E+02 1.05E+02 1.02E+02 9.75E+01 1.17E+02 1.17E+02 1.02E+02 9.97E+01 1.14E+02 9.69E+01 9.93E+01 24 Hr Anneal 60 9.97E+01 1.07E+02 1.05E+02 1.02E+02 9.75E+01 1.17E+02 1.17E+02 1.02E+02 9.97E+01 1.15E+02 9.69E+01 9.92E+01 168 Hr Anneal 70 9.96E+01 1.08E+02 1.05E+02 1.02E+02 9.76E+01 1.18E+02 1.17E+02 1.02E+02 9.98E+01 1.14E+02 9.69E+01 9.93E+01 0 9.96E+01 1.07E+02 1.05E+02 1.02E+02 9.74E+01 1.19E+02 1.18E+02 1.02E+02 1.00E+02 1.13E+02 9.70E+01 9.94E+01 10 9.96E+01 1.07E+02 1.05E+02 1.02E+02 9.74E+01 1.19E+02 1.18E+02 1.02E+02 9.99E+01 1.13E+02 9.69E+01 9.93E+01 Total Dose (krad(Si)) 20 30 9.96E+01 9.97E+01 1.07E+02 1.07E+02 1.05E+02 1.05E+02 1.02E+02 1.02E+02 9.75E+01 9.75E+01 1.19E+02 1.18E+02 1.18E+02 1.18E+02 1.02E+02 1.02E+02 9.99E+01 9.98E+01 1.13E+02 1.13E+02 9.69E+01 9.69E+01 9.93E+01 9.93E+01 1.02E+02 3.96E+00 1.13E+02 9.13E+01 1.02E+02 3.90E+00 1.13E+02 9.14E+01 1.02E+02 3.89E+00 1.13E+02 9.15E+01 1.02E+02 3.89E+00 1.13E+02 9.15E+01 1.02E+02 3.83E+00 1.13E+02 9.16E+01 1.02E+02 3.82E+00 1.13E+02 9.16E+01 1.02E+02 4.06E+00 1.14E+02 9.12E+01 1.11E+02 9.07E+00 1.35E+02 8.56E+01 9.00E+01 PASS 1.10E+02 9.01E+00 1.35E+02 8.57E+01 8.60E+01 PASS 1.10E+02 8.95E+00 1.35E+02 8.58E+01 8.60E+01 PASS 1.10E+02 8.86E+00 1.35E+02 8.60E+01 8.60E+01 PASS 1.10E+02 8.53E+00 1.33E+02 8.66E+01 8.60E+01 PASS 1.10E+02 8.46E+00 1.33E+02 8.67E+01 8.60E+01 PASS 1.10E+02 8.70E+00 1.34E+02 8.63E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 180 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.85. Plot of Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 181 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.85. Raw data for Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.01E+02 1.02E+02 1.00E+02 1.02E+02 1.05E+02 9.85E+01 1.01E+02 1.20E+02 1.07E+02 1.21E+02 1.16E+02 1.06E+02 24 Hr Anneal 60 1.01E+02 1.02E+02 1.00E+02 1.02E+02 1.05E+02 9.85E+01 1.01E+02 1.20E+02 1.07E+02 1.21E+02 1.16E+02 1.06E+02 168 Hr Anneal 70 1.01E+02 1.02E+02 1.00E+02 1.02E+02 1.05E+02 9.88E+01 1.01E+02 1.20E+02 1.07E+02 1.25E+02 1.16E+02 1.06E+02 0 1.01E+02 1.02E+02 1.00E+02 1.02E+02 1.05E+02 9.86E+01 1.01E+02 1.26E+02 1.08E+02 1.18E+02 1.17E+02 1.06E+02 10 1.01E+02 1.02E+02 1.00E+02 1.02E+02 1.05E+02 9.85E+01 1.01E+02 1.23E+02 1.08E+02 1.18E+02 1.17E+02 1.06E+02 Total Dose (krad(Si)) 20 30 1.01E+02 1.01E+02 1.02E+02 1.02E+02 1.00E+02 1.00E+02 1.02E+02 1.02E+02 1.05E+02 1.05E+02 9.85E+01 9.85E+01 1.01E+02 1.01E+02 1.23E+02 1.22E+02 1.08E+02 1.08E+02 1.19E+02 1.19E+02 1.17E+02 1.17E+02 1.06E+02 1.06E+02 1.02E+02 1.85E+00 1.07E+02 9.69E+01 1.02E+02 1.84E+00 1.07E+02 9.70E+01 1.02E+02 1.83E+00 1.07E+02 9.70E+01 1.02E+02 1.85E+00 1.07E+02 9.70E+01 1.02E+02 1.84E+00 1.07E+02 9.70E+01 1.02E+02 1.83E+00 1.07E+02 9.70E+01 1.02E+02 1.96E+00 1.07E+02 9.68E+01 1.10E+02 1.14E+01 1.41E+02 7.90E+01 9.00E+01 PASS 1.10E+02 1.08E+01 1.39E+02 8.03E+01 8.60E+01 PASS 1.10E+02 1.08E+01 1.40E+02 8.01E+01 8.60E+01 PASS 1.10E+02 1.07E+01 1.39E+02 8.05E+01 8.60E+01 PASS 1.10E+02 1.06E+01 1.39E+02 8.05E+01 8.60E+01 PASS 1.10E+02 1.07E+01 1.39E+02 8.02E+01 8.60E+01 PASS 1.10E+02 1.15E+01 1.42E+02 7.88E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 182 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.86. Plot of Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 183 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.86. Raw data for Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.06E+02 1.09E+02 1.32E+02 1.24E+02 1.11E+02 1.17E+02 1.05E+02 1.07E+02 1.12E+02 1.00E+02 1.02E+02 1.03E+02 24 Hr Anneal 60 1.07E+02 1.09E+02 1.38E+02 1.25E+02 1.11E+02 1.17E+02 1.05E+02 1.07E+02 1.12E+02 1.00E+02 1.02E+02 1.03E+02 168 Hr Anneal 70 1.07E+02 1.10E+02 1.25E+02 1.22E+02 1.13E+02 1.16E+02 1.05E+02 1.08E+02 1.11E+02 1.00E+02 1.02E+02 1.03E+02 0 1.06E+02 1.10E+02 1.35E+02 1.23E+02 1.11E+02 1.19E+02 1.05E+02 1.09E+02 1.12E+02 1.00E+02 1.02E+02 1.04E+02 10 1.06E+02 1.10E+02 1.32E+02 1.23E+02 1.11E+02 1.19E+02 1.05E+02 1.08E+02 1.12E+02 1.00E+02 1.02E+02 1.03E+02 Total Dose (krad(Si)) 20 30 1.06E+02 1.06E+02 1.10E+02 1.10E+02 1.32E+02 1.30E+02 1.23E+02 1.23E+02 1.11E+02 1.11E+02 1.18E+02 1.18E+02 1.05E+02 1.05E+02 1.08E+02 1.08E+02 1.12E+02 1.12E+02 1.00E+02 1.00E+02 1.02E+02 1.02E+02 1.03E+02 1.03E+02 1.17E+02 1.20E+01 1.50E+02 8.42E+01 1.16E+02 1.06E+01 1.45E+02 8.72E+01 1.16E+02 1.08E+01 1.46E+02 8.68E+01 1.16E+02 9.87E+00 1.43E+02 8.89E+01 1.17E+02 1.08E+01 1.46E+02 8.69E+01 1.18E+02 1.33E+01 1.54E+02 8.14E+01 1.15E+02 7.91E+00 1.37E+02 9.35E+01 1.09E+02 7.01E+00 1.28E+02 8.99E+01 9.00E+01 PASS 1.09E+02 6.96E+00 1.28E+02 8.99E+01 8.60E+01 PASS 1.09E+02 6.77E+00 1.27E+02 9.02E+01 8.60E+01 PASS 1.09E+02 6.81E+00 1.27E+02 9.00E+01 8.60E+01 PASS 1.08E+02 6.38E+00 1.26E+02 9.07E+01 8.60E+01 PASS 1.08E+02 6.39E+00 1.26E+02 9.07E+01 8.60E+01 PASS 1.08E+02 6.11E+00 1.25E+02 9.13E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 184 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.87. Plot of CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 185 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.87. Raw data for CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 9.69E+01 1.16E+02 1.02E+02 1.18E+02 1.01E+02 1.19E+02 1.18E+02 1.08E+02 1.07E+02 1.05E+02 1.19E+02 1.10E+02 24 Hr Anneal 60 9.70E+01 1.16E+02 1.02E+02 1.18E+02 1.01E+02 1.19E+02 1.18E+02 1.07E+02 1.07E+02 1.05E+02 1.19E+02 1.10E+02 168 Hr Anneal 70 9.70E+01 1.14E+02 1.02E+02 1.17E+02 1.00E+02 1.24E+02 1.15E+02 1.08E+02 1.07E+02 1.05E+02 1.19E+02 1.10E+02 0 9.67E+01 1.16E+02 1.02E+02 1.17E+02 1.01E+02 1.19E+02 1.19E+02 1.07E+02 1.06E+02 1.05E+02 1.19E+02 1.10E+02 10 9.68E+01 1.16E+02 1.02E+02 1.17E+02 1.01E+02 1.19E+02 1.19E+02 1.07E+02 1.06E+02 1.05E+02 1.19E+02 1.10E+02 Total Dose (krad(Si)) 20 30 9.68E+01 9.68E+01 1.16E+02 1.16E+02 1.02E+02 1.02E+02 1.18E+02 1.18E+02 1.01E+02 1.01E+02 1.19E+02 1.19E+02 1.18E+02 1.18E+02 1.07E+02 1.07E+02 1.06E+02 1.07E+02 1.05E+02 1.05E+02 1.19E+02 1.19E+02 1.10E+02 1.10E+02 1.06E+02 9.30E+00 1.32E+02 8.10E+01 1.07E+02 9.38E+00 1.32E+02 8.08E+01 1.07E+02 9.56E+00 1.33E+02 8.04E+01 1.07E+02 9.52E+00 1.33E+02 8.05E+01 1.07E+02 9.69E+00 1.33E+02 8.02E+01 1.07E+02 9.81E+00 1.34E+02 8.00E+01 1.06E+02 9.01E+00 1.31E+02 8.14E+01 1.11E+02 7.25E+00 1.31E+02 9.15E+01 8.40E+01 PASS 1.11E+02 7.10E+00 1.31E+02 9.18E+01 8.30E+01 PASS 1.11E+02 7.00E+00 1.30E+02 9.21E+01 8.30E+01 PASS 1.11E+02 6.89E+00 1.30E+02 9.24E+01 8.30E+01 PASS 1.11E+02 6.59E+00 1.29E+02 9.32E+01 8.30E+01 PASS 1.11E+02 6.52E+00 1.29E+02 9.33E+01 8.30E+01 PASS 1.12E+02 7.92E+00 1.33E+02 8.99E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 186 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.40E+02 CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.88. Plot of CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 187 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.88. Raw data for CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.18E+02 1.08E+02 1.09E+02 1.25E+02 1.02E+02 9.96E+01 1.02E+02 1.03E+02 1.04E+02 1.20E+02 9.79E+01 1.05E+02 24 Hr Anneal 60 1.18E+02 1.08E+02 1.09E+02 1.26E+02 1.02E+02 9.96E+01 1.02E+02 1.03E+02 1.04E+02 1.20E+02 9.79E+01 1.05E+02 168 Hr Anneal 70 1.17E+02 1.08E+02 1.08E+02 1.40E+02 1.02E+02 9.98E+01 1.02E+02 1.03E+02 1.05E+02 1.17E+02 9.79E+01 1.05E+02 0 1.16E+02 1.08E+02 1.09E+02 1.33E+02 1.02E+02 9.94E+01 1.02E+02 1.03E+02 1.04E+02 1.20E+02 9.79E+01 1.05E+02 10 1.16E+02 1.08E+02 1.09E+02 1.30E+02 1.02E+02 9.94E+01 1.02E+02 1.03E+02 1.04E+02 1.20E+02 9.79E+01 1.05E+02 Total Dose (krad(Si)) 20 30 1.17E+02 1.17E+02 1.08E+02 1.08E+02 1.09E+02 1.09E+02 1.31E+02 1.30E+02 1.02E+02 1.02E+02 9.94E+01 9.94E+01 1.02E+02 1.02E+02 1.03E+02 1.03E+02 1.04E+02 1.04E+02 1.20E+02 1.19E+02 9.78E+01 9.78E+01 1.05E+02 1.05E+02 1.14E+02 1.21E+01 1.47E+02 8.04E+01 1.13E+02 1.09E+01 1.43E+02 8.32E+01 1.13E+02 1.10E+01 1.43E+02 8.30E+01 1.13E+02 1.08E+01 1.43E+02 8.35E+01 1.12E+02 9.10E+00 1.37E+02 8.75E+01 1.13E+02 9.34E+00 1.38E+02 8.70E+01 1.15E+02 1.48E+01 1.56E+02 7.42E+01 1.06E+02 8.24E+00 1.28E+02 8.32E+01 8.40E+01 PASS 1.06E+02 8.11E+00 1.28E+02 8.34E+01 8.30E+01 PASS 1.06E+02 8.17E+00 1.28E+02 8.33E+01 8.30E+01 PASS 1.06E+02 7.89E+00 1.27E+02 8.39E+01 8.30E+01 PASS 1.06E+02 8.15E+00 1.28E+02 8.34E+01 8.30E+01 PASS 1.06E+02 8.02E+00 1.28E+02 8.38E+01 8.30E+01 PASS 1.05E+02 6.83E+00 1.24E+02 8.67E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 188 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.89. Plot of Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 189 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.89. Raw data for Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.14E+02 1.08E+02 1.12E+02 1.30E+02 1.19E+02 1.09E+02 1.10E+02 1.10E+02 1.07E+02 1.26E+02 1.07E+02 1.24E+02 24 Hr Anneal 60 1.14E+02 1.08E+02 1.12E+02 1.30E+02 1.19E+02 1.09E+02 1.10E+02 1.10E+02 1.07E+02 1.26E+02 1.07E+02 1.25E+02 168 Hr Anneal 70 1.14E+02 1.07E+02 1.12E+02 1.31E+02 1.19E+02 1.09E+02 1.10E+02 1.10E+02 1.07E+02 1.26E+02 1.07E+02 1.24E+02 0 1.14E+02 1.07E+02 1.12E+02 1.30E+02 1.18E+02 1.09E+02 1.10E+02 1.10E+02 1.07E+02 1.26E+02 1.07E+02 1.24E+02 10 1.14E+02 1.07E+02 1.12E+02 1.30E+02 1.18E+02 1.09E+02 1.10E+02 1.10E+02 1.07E+02 1.26E+02 1.07E+02 1.24E+02 Total Dose (krad(Si)) 20 30 1.14E+02 1.14E+02 1.07E+02 1.07E+02 1.12E+02 1.12E+02 1.30E+02 1.30E+02 1.18E+02 1.19E+02 1.09E+02 1.09E+02 1.10E+02 1.10E+02 1.10E+02 1.10E+02 1.07E+02 1.07E+02 1.26E+02 1.26E+02 1.07E+02 1.07E+02 1.24E+02 1.24E+02 1.16E+02 8.78E+00 1.40E+02 9.23E+01 1.16E+02 8.74E+00 1.40E+02 9.24E+01 1.16E+02 8.73E+00 1.40E+02 9.24E+01 1.16E+02 8.70E+00 1.40E+02 9.25E+01 1.16E+02 8.59E+00 1.40E+02 9.28E+01 1.17E+02 8.73E+00 1.40E+02 9.26E+01 1.16E+02 8.84E+00 1.41E+02 9.22E+01 1.12E+02 7.87E+00 1.34E+02 9.08E+01 9.00E+01 PASS 1.12E+02 7.88E+00 1.34E+02 9.09E+01 9.00E+01 PASS 1.12E+02 7.85E+00 1.34E+02 9.10E+01 9.00E+01 PASS 1.12E+02 7.67E+00 1.33E+02 9.13E+01 9.00E+01 PASS 1.13E+02 7.70E+00 1.34E+02 9.14E+01 9.00E+01 PASS 1.12E+02 7.59E+00 1.33E+02 9.17E+01 9.00E+01 PASS 1.13E+02 7.74E+00 1.34E+02 9.13E+01 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 190 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.90. Plot of Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 191 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.90. Raw data for Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.28E+02 1.16E+02 1.13E+02 1.13E+02 1.25E+02 1.08E+02 1.08E+02 1.14E+02 1.07E+02 1.05E+02 1.36E+02 1.14E+02 24 Hr Anneal 60 1.27E+02 1.16E+02 1.13E+02 1.13E+02 1.25E+02 1.08E+02 1.08E+02 1.13E+02 1.07E+02 1.06E+02 1.35E+02 1.14E+02 168 Hr Anneal 70 1.28E+02 1.16E+02 1.13E+02 1.13E+02 1.25E+02 1.08E+02 1.08E+02 1.14E+02 1.07E+02 1.06E+02 1.36E+02 1.14E+02 0 1.27E+02 1.16E+02 1.13E+02 1.13E+02 1.24E+02 1.08E+02 1.08E+02 1.13E+02 1.06E+02 1.05E+02 1.35E+02 1.14E+02 10 1.28E+02 1.16E+02 1.13E+02 1.13E+02 1.25E+02 1.08E+02 1.08E+02 1.14E+02 1.06E+02 1.05E+02 1.35E+02 1.14E+02 Total Dose (krad(Si)) 20 30 1.27E+02 1.28E+02 1.16E+02 1.16E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.25E+02 1.25E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.14E+02 1.14E+02 1.06E+02 1.06E+02 1.05E+02 1.05E+02 1.35E+02 1.35E+02 1.14E+02 1.14E+02 1.19E+02 6.74E+00 1.37E+02 1.00E+02 1.19E+02 6.84E+00 1.38E+02 1.00E+02 1.19E+02 6.77E+00 1.37E+02 1.00E+02 1.19E+02 6.90E+00 1.38E+02 1.00E+02 1.19E+02 6.90E+00 1.38E+02 1.00E+02 1.19E+02 6.83E+00 1.38E+02 1.00E+02 1.19E+02 6.81E+00 1.38E+02 1.00E+02 1.08E+02 3.12E+00 1.17E+02 9.96E+01 9.00E+01 PASS 1.08E+02 3.12E+00 1.17E+02 9.97E+01 9.00E+01 PASS 1.08E+02 3.15E+00 1.17E+02 9.96E+01 9.00E+01 PASS 1.08E+02 3.16E+00 1.17E+02 9.95E+01 9.00E+01 PASS 1.08E+02 3.13E+00 1.17E+02 9.97E+01 9.00E+01 PASS 1.08E+02 3.07E+00 1.17E+02 9.99E+01 9.00E+01 PASS 1.08E+02 3.11E+00 1.17E+02 9.97E+01 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 192 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.91. Plot of Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 193 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.91. Raw data for Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.10E+02 1.18E+02 1.14E+02 1.21E+02 1.11E+02 1.13E+02 1.03E+02 1.13E+02 1.09E+02 1.22E+02 1.13E+02 1.13E+02 24 Hr Anneal 60 1.10E+02 1.18E+02 1.14E+02 1.21E+02 1.11E+02 1.13E+02 1.03E+02 1.13E+02 1.09E+02 1.22E+02 1.13E+02 1.13E+02 168 Hr Anneal 70 1.10E+02 1.18E+02 1.13E+02 1.21E+02 1.10E+02 1.13E+02 1.03E+02 1.12E+02 1.09E+02 1.22E+02 1.13E+02 1.13E+02 0 1.09E+02 1.18E+02 1.13E+02 1.21E+02 1.10E+02 1.13E+02 1.03E+02 1.12E+02 1.09E+02 1.22E+02 1.13E+02 1.13E+02 10 1.10E+02 1.18E+02 1.13E+02 1.21E+02 1.10E+02 1.13E+02 1.03E+02 1.12E+02 1.09E+02 1.22E+02 1.13E+02 1.13E+02 Total Dose (krad(Si)) 20 30 1.10E+02 1.10E+02 1.18E+02 1.18E+02 1.13E+02 1.13E+02 1.21E+02 1.21E+02 1.10E+02 1.10E+02 1.13E+02 1.13E+02 1.03E+02 1.03E+02 1.12E+02 1.12E+02 1.09E+02 1.09E+02 1.22E+02 1.22E+02 1.13E+02 1.13E+02 1.13E+02 1.13E+02 1.14E+02 4.92E+00 1.28E+02 1.01E+02 1.15E+02 4.94E+00 1.28E+02 1.01E+02 1.15E+02 4.93E+00 1.28E+02 1.01E+02 1.15E+02 4.87E+00 1.28E+02 1.01E+02 1.15E+02 4.87E+00 1.28E+02 1.01E+02 1.15E+02 4.84E+00 1.28E+02 1.01E+02 1.15E+02 4.90E+00 1.28E+02 1.01E+02 1.12E+02 7.16E+00 1.31E+02 9.21E+01 9.00E+01 PASS 1.12E+02 7.07E+00 1.31E+02 9.24E+01 9.00E+01 PASS 1.12E+02 7.02E+00 1.31E+02 9.25E+01 9.00E+01 PASS 1.12E+02 7.02E+00 1.31E+02 9.25E+01 9.00E+01 PASS 1.12E+02 6.98E+00 1.31E+02 9.27E+01 9.00E+01 PASS 1.12E+02 7.02E+00 1.31E+02 9.27E+01 9.00E+01 PASS 1.12E+02 7.01E+00 1.31E+02 9.26E+01 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 194 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.92. Plot of Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 195 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.92. Raw data for Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.10E+02 1.08E+02 1.21E+02 1.14E+02 1.07E+02 1.10E+02 1.20E+02 1.11E+02 1.15E+02 1.19E+02 1.04E+02 1.07E+02 24 Hr Anneal 60 1.10E+02 1.08E+02 1.21E+02 1.14E+02 1.07E+02 1.10E+02 1.20E+02 1.11E+02 1.15E+02 1.19E+02 1.04E+02 1.07E+02 168 Hr Anneal 70 1.10E+02 1.08E+02 1.21E+02 1.14E+02 1.07E+02 1.10E+02 1.20E+02 1.11E+02 1.15E+02 1.19E+02 1.04E+02 1.07E+02 0 1.10E+02 1.08E+02 1.20E+02 1.14E+02 1.07E+02 1.10E+02 1.20E+02 1.10E+02 1.15E+02 1.19E+02 1.04E+02 1.07E+02 10 1.10E+02 1.08E+02 1.20E+02 1.14E+02 1.07E+02 1.10E+02 1.20E+02 1.10E+02 1.15E+02 1.19E+02 1.04E+02 1.07E+02 Total Dose (krad(Si)) 20 30 1.10E+02 1.10E+02 1.08E+02 1.08E+02 1.21E+02 1.21E+02 1.14E+02 1.14E+02 1.07E+02 1.07E+02 1.10E+02 1.10E+02 1.20E+02 1.20E+02 1.10E+02 1.10E+02 1.15E+02 1.15E+02 1.19E+02 1.19E+02 1.04E+02 1.04E+02 1.07E+02 1.07E+02 1.12E+02 5.35E+00 1.27E+02 9.72E+01 1.12E+02 5.38E+00 1.27E+02 9.72E+01 1.12E+02 5.45E+00 1.27E+02 9.70E+01 1.12E+02 5.52E+00 1.27E+02 9.69E+01 1.12E+02 5.56E+00 1.27E+02 9.69E+01 1.12E+02 5.63E+00 1.28E+02 9.67E+01 1.12E+02 5.44E+00 1.27E+02 9.71E+01 1.15E+02 4.71E+00 1.28E+02 1.02E+02 9.00E+01 PASS 1.15E+02 4.69E+00 1.28E+02 1.02E+02 9.00E+01 PASS 1.15E+02 4.65E+00 1.28E+02 1.02E+02 9.00E+01 PASS 1.15E+02 4.66E+00 1.28E+02 1.02E+02 9.00E+01 PASS 1.15E+02 4.61E+00 1.28E+02 1.02E+02 9.00E+01 PASS 1.15E+02 4.56E+00 1.28E+02 1.02E+02 9.00E+01 PASS 1.15E+02 4.64E+00 1.28E+02 1.02E+02 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 196 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.93. Plot of PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 197 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.93. Raw data for PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V Device 557 563 564 567 569 570 571 572 573 574 584 585 0 1.06E+02 1.29E+02 1.16E+02 1.13E+02 1.10E+02 1.27E+02 1.13E+02 1.37E+02 1.11E+02 1.16E+02 1.14E+02 1.09E+02 Biased Statistics Average Biased 1.15E+02 Std Dev Biased 8.89E+00 Ps90%/90% (+KTL) Biased 1.39E+02 Ps90%/90% (-KTL) Biased 9.03E+01 Un-Biased Statistics Average Un-Biased 1.21E+02 Std Dev Un-Biased 1.10E+01 Ps90%/90% (+KTL) Un-Biased 1.51E+02 Ps90%/90% (-KTL) Un-Biased 9.09E+01 Specification MIN 8.30E+01 Status PASS 50 1.06E+02 1.30E+02 1.16E+02 1.13E+02 1.10E+02 1.28E+02 1.13E+02 1.41E+02 1.11E+02 1.16E+02 1.14E+02 1.09E+02 24 Hr Anneal 60 1.06E+02 1.29E+02 1.16E+02 1.13E+02 1.10E+02 1.27E+02 1.14E+02 1.38E+02 1.11E+02 1.16E+02 1.14E+02 1.09E+02 168 Hr Anneal 70 1.06E+02 1.28E+02 1.16E+02 1.13E+02 1.10E+02 1.28E+02 1.13E+02 1.42E+02 1.11E+02 1.16E+02 1.14E+02 1.09E+02 1.15E+02 9.01E+00 1.39E+02 9.00E+01 1.15E+02 9.04E+00 1.40E+02 9.00E+01 1.15E+02 9.03E+00 1.40E+02 9.01E+01 1.15E+02 8.64E+00 1.38E+02 9.09E+01 1.21E+02 1.16E+01 1.53E+02 8.95E+01 8.30E+01 PASS 1.22E+02 1.25E+01 1.56E+02 8.77E+01 8.30E+01 PASS 1.21E+02 1.13E+01 1.52E+02 9.03E+01 8.30E+01 PASS 1.22E+02 1.27E+01 1.57E+02 8.71E+01 8.30E+01 PASS 10 1.06E+02 1.29E+02 1.16E+02 1.13E+02 1.10E+02 1.27E+02 1.13E+02 1.38E+02 1.11E+02 1.16E+02 1.13E+02 1.09E+02 Total Dose (krad(Si)) 20 30 1.06E+02 1.06E+02 1.29E+02 1.29E+02 1.16E+02 1.16E+02 1.13E+02 1.13E+02 1.10E+02 1.10E+02 1.27E+02 1.27E+02 1.13E+02 1.13E+02 1.42E+02 1.39E+02 1.11E+02 1.11E+02 1.16E+02 1.16E+02 1.14E+02 1.13E+02 1.09E+02 1.09E+02 1.15E+02 8.72E+00 1.38E+02 9.06E+01 1.15E+02 9.01E+00 1.39E+02 9.00E+01 1.21E+02 1.12E+01 1.52E+02 9.05E+01 8.30E+01 PASS 1.22E+02 1.29E+01 1.57E+02 8.67E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 198 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.94. Plot of PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 199 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.94. Raw data for PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V Device 557 563 564 567 569 570 571 572 573 574 584 585 0 1.08E+02 1.11E+02 1.45E+02 1.17E+02 1.09E+02 1.04E+02 1.10E+02 1.29E+02 1.19E+02 1.04E+02 1.14E+02 1.30E+02 Biased Statistics Average Biased 1.18E+02 Std Dev Biased 1.56E+01 Ps90%/90% (+KTL) Biased 1.61E+02 Ps90%/90% (-KTL) Biased 7.54E+01 Un-Biased Statistics Average Un-Biased 1.13E+02 Std Dev Un-Biased 1.06E+01 Ps90%/90% (+KTL) Un-Biased 1.42E+02 Ps90%/90% (-KTL) Un-Biased 8.42E+01 Specification MIN 8.30E+01 Status PASS 50 1.09E+02 1.11E+02 1.43E+02 1.17E+02 1.09E+02 1.04E+02 1.10E+02 1.31E+02 1.19E+02 1.04E+02 1.14E+02 1.30E+02 24 Hr Anneal 60 1.09E+02 1.11E+02 1.41E+02 1.17E+02 1.09E+02 1.04E+02 1.10E+02 1.33E+02 1.19E+02 1.04E+02 1.14E+02 1.29E+02 168 Hr Anneal 70 1.09E+02 1.11E+02 1.47E+02 1.17E+02 1.09E+02 1.04E+02 1.10E+02 1.31E+02 1.19E+02 1.04E+02 1.14E+02 1.29E+02 1.18E+02 1.51E+01 1.60E+02 7.66E+01 1.18E+02 1.46E+01 1.58E+02 7.78E+01 1.17E+02 1.36E+01 1.55E+02 8.03E+01 1.19E+02 1.61E+01 1.63E+02 7.44E+01 1.13E+02 1.08E+01 1.43E+02 8.37E+01 8.30E+01 PASS 1.14E+02 1.15E+01 1.45E+02 8.23E+01 8.30E+01 PASS 1.14E+02 1.21E+01 1.47E+02 8.09E+01 8.30E+01 PASS 1.14E+02 1.12E+01 1.44E+02 8.28E+01 8.30E+01 PASS 10 1.09E+02 1.11E+02 1.47E+02 1.17E+02 1.09E+02 1.04E+02 1.10E+02 1.29E+02 1.19E+02 1.04E+02 1.14E+02 1.30E+02 Total Dose (krad(Si)) 20 30 1.09E+02 1.09E+02 1.11E+02 1.11E+02 1.41E+02 1.44E+02 1.17E+02 1.17E+02 1.09E+02 1.09E+02 1.04E+02 1.04E+02 1.10E+02 1.10E+02 1.29E+02 1.29E+02 1.19E+02 1.19E+02 1.04E+02 1.04E+02 1.14E+02 1.14E+02 1.28E+02 1.30E+02 1.19E+02 1.63E+01 1.63E+02 7.40E+01 1.17E+02 1.38E+01 1.55E+02 7.96E+01 1.13E+02 1.08E+01 1.43E+02 8.37E+01 8.30E+01 PASS 1.13E+02 1.08E+01 1.43E+02 8.37E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 200 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 0.00E+00 +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.95. Plot of +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 201 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.95. Raw data for +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -3.71E-02 -3.59E-02 -3.58E-02 -3.61E-02 -3.70E-02 -3.53E-02 -3.54E-02 -3.70E-02 -3.47E-02 -3.55E-02 -3.63E-02 -3.73E-02 Total Dose (krad(Si)) 20 30 -3.64E-02 -3.62E-02 -3.50E-02 -3.49E-02 -3.50E-02 -3.49E-02 -3.53E-02 -3.52E-02 -3.61E-02 -3.60E-02 -3.50E-02 -3.48E-02 -3.50E-02 -3.48E-02 -3.65E-02 -3.62E-02 -3.43E-02 -3.41E-02 -3.52E-02 -3.50E-02 -3.65E-02 -3.66E-02 -3.76E-02 -3.74E-02 10 -3.67E-02 -3.53E-02 -3.53E-02 -3.57E-02 -3.66E-02 -3.52E-02 -3.52E-02 -3.66E-02 -3.44E-02 -3.54E-02 -3.64E-02 -3.74E-02 50 -3.53E-02 -3.42E-02 -3.42E-02 -3.44E-02 -3.51E-02 -3.38E-02 -3.38E-02 -3.52E-02 -3.31E-02 -3.40E-02 -3.62E-02 -3.71E-02 24 Hr Anneal 60 -3.52E-02 -3.40E-02 -3.39E-02 -3.43E-02 -3.51E-02 -3.38E-02 -3.38E-02 -3.51E-02 -3.31E-02 -3.39E-02 -3.61E-02 -3.69E-02 168 Hr Anneal 70 -3.59E-02 -3.47E-02 -3.47E-02 -3.50E-02 -3.58E-02 -3.43E-02 -3.43E-02 -3.57E-02 -3.36E-02 -3.45E-02 -3.63E-02 -3.73E-02 -3.64E-02 -3.59E-02 -3.56E-02 -3.54E-02 -3.46E-02 -3.45E-02 -3.52E-02 6.14E-04 6.85E-04 6.31E-04 6.07E-04 5.53E-04 6.20E-04 5.72E-04 -3.47E-02 -3.40E-02 -3.38E-02 -3.38E-02 -3.31E-02 -3.28E-02 -3.37E-02 -3.80E-02 -3.78E-02 -3.73E-02 -3.71E-02 -3.61E-02 -3.62E-02 -3.68E-02 -3.56E-02 8.50E-04 -3.32E-02 -3.79E-02 -1.50E-02 PASS -3.54E-02 8.11E-04 -3.32E-02 -3.76E-02 -1.00E-02 PASS -3.52E-02 8.09E-04 -3.30E-02 -3.74E-02 -1.00E-02 PASS -3.49E-02 7.82E-04 -3.28E-02 -3.71E-02 -1.00E-02 PASS -3.40E-02 7.67E-04 -3.19E-02 -3.61E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 202 -3.39E-02 7.48E-04 -3.19E-02 -3.60E-02 -1.00E-02 PASS -3.45E-02 7.70E-04 -3.24E-02 -3.66E-02 -1.00E-02 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 0.00E+00 +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.96. Plot of +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 203 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.96. Raw data for +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -3.95E-02 -3.63E-02 -3.63E-02 -3.58E-02 -3.62E-02 -3.63E-02 -3.55E-02 -3.73E-02 -3.41E-02 -3.72E-02 -3.64E-02 -3.59E-02 Total Dose (krad(Si)) 20 30 -3.87E-02 -3.85E-02 -3.55E-02 -3.54E-02 -3.54E-02 -3.53E-02 -3.49E-02 -3.48E-02 -3.53E-02 -3.52E-02 -3.58E-02 -3.56E-02 -3.51E-02 -3.48E-02 -3.68E-02 -3.65E-02 -3.37E-02 -3.34E-02 -3.68E-02 -3.65E-02 -3.65E-02 -3.66E-02 -3.61E-02 -3.60E-02 10 -3.91E-02 -3.57E-02 -3.58E-02 -3.54E-02 -3.58E-02 -3.61E-02 -3.53E-02 -3.70E-02 -3.38E-02 -3.70E-02 -3.65E-02 -3.60E-02 50 -3.76E-02 -3.46E-02 -3.46E-02 -3.39E-02 -3.43E-02 -3.46E-02 -3.38E-02 -3.55E-02 -3.24E-02 -3.56E-02 -3.62E-02 -3.56E-02 24 Hr Anneal 60 -3.75E-02 -3.44E-02 -3.44E-02 -3.39E-02 -3.43E-02 -3.46E-02 -3.38E-02 -3.55E-02 -3.24E-02 -3.55E-02 -3.61E-02 -3.54E-02 168 Hr Anneal 70 -3.82E-02 -3.52E-02 -3.52E-02 -3.46E-02 -3.50E-02 -3.52E-02 -3.44E-02 -3.61E-02 -3.30E-02 -3.61E-02 -3.64E-02 -3.58E-02 -3.68E-02 -3.63E-02 -3.60E-02 -3.58E-02 -3.50E-02 -3.49E-02 -3.56E-02 1.52E-03 1.55E-03 1.55E-03 1.53E-03 1.48E-03 1.49E-03 1.47E-03 -3.26E-02 -3.21E-02 -3.17E-02 -3.17E-02 -3.10E-02 -3.08E-02 -3.16E-02 -4.10E-02 -4.06E-02 -4.02E-02 -4.00E-02 -3.91E-02 -3.90E-02 -3.97E-02 -3.61E-02 1.33E-03 -3.24E-02 -3.97E-02 -1.50E-02 PASS -3.58E-02 1.35E-03 -3.21E-02 -3.95E-02 -1.00E-02 PASS -3.56E-02 1.33E-03 -3.20E-02 -3.93E-02 -1.00E-02 PASS -3.54E-02 1.31E-03 -3.18E-02 -3.90E-02 -1.00E-02 PASS -3.44E-02 1.30E-03 -3.08E-02 -3.80E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 204 -3.44E-02 1.28E-03 -3.08E-02 -3.79E-02 -1.00E-02 PASS -3.49E-02 1.29E-03 -3.14E-02 -3.85E-02 -1.00E-02 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 0.00E+00 +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.97. Plot of +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 205 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.97. Raw data for +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -4.01E-02 -3.62E-02 -3.71E-02 -3.66E-02 -3.69E-02 -3.65E-02 -3.63E-02 -3.80E-02 -3.44E-02 -3.82E-02 -3.65E-02 -3.64E-02 Total Dose (krad(Si)) 20 30 -3.93E-02 -3.92E-02 -3.54E-02 -3.52E-02 -3.63E-02 -3.62E-02 -3.58E-02 -3.56E-02 -3.59E-02 -3.58E-02 -3.61E-02 -3.59E-02 -3.59E-02 -3.56E-02 -3.75E-02 -3.72E-02 -3.40E-02 -3.38E-02 -3.79E-02 -3.76E-02 -3.66E-02 -3.67E-02 -3.67E-02 -3.66E-02 10 -3.97E-02 -3.56E-02 -3.67E-02 -3.62E-02 -3.64E-02 -3.64E-02 -3.61E-02 -3.76E-02 -3.42E-02 -3.81E-02 -3.66E-02 -3.66E-02 50 -3.82E-02 -3.45E-02 -3.55E-02 -3.48E-02 -3.50E-02 -3.48E-02 -3.46E-02 -3.61E-02 -3.28E-02 -3.66E-02 -3.63E-02 -3.62E-02 24 Hr Anneal 60 -3.81E-02 -3.43E-02 -3.52E-02 -3.47E-02 -3.49E-02 -3.48E-02 -3.46E-02 -3.61E-02 -3.28E-02 -3.65E-02 -3.63E-02 -3.60E-02 168 Hr Anneal 70 -3.88E-02 -3.51E-02 -3.60E-02 -3.54E-02 -3.57E-02 -3.54E-02 -3.52E-02 -3.67E-02 -3.34E-02 -3.71E-02 -3.65E-02 -3.64E-02 -3.74E-02 -3.69E-02 -3.65E-02 -3.64E-02 -3.56E-02 -3.55E-02 -3.62E-02 1.57E-03 1.62E-03 1.59E-03 1.58E-03 1.51E-03 1.53E-03 1.50E-03 -3.31E-02 -3.25E-02 -3.22E-02 -3.21E-02 -3.14E-02 -3.13E-02 -3.21E-02 -4.17E-02 -4.14E-02 -4.09E-02 -4.07E-02 -3.97E-02 -3.97E-02 -4.03E-02 -3.67E-02 1.51E-03 -3.25E-02 -4.08E-02 -1.50E-02 PASS -3.65E-02 1.53E-03 -3.23E-02 -4.06E-02 -1.00E-02 PASS -3.63E-02 1.51E-03 -3.21E-02 -4.04E-02 -1.00E-02 PASS -3.60E-02 1.48E-03 -3.19E-02 -4.01E-02 -1.00E-02 PASS -3.50E-02 1.48E-03 -3.09E-02 -3.90E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 206 -3.49E-02 1.45E-03 -3.10E-02 -3.89E-02 -1.00E-02 PASS -3.55E-02 1.46E-03 -3.15E-02 -3.96E-02 -1.00E-02 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 0.00E+00 +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.98. Plot of +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 207 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.98. Raw data for +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -3.77E-02 -3.67E-02 -3.64E-02 -3.71E-02 -3.76E-02 -3.63E-02 -3.62E-02 -3.76E-02 -3.53E-02 -3.64E-02 -3.71E-02 -3.83E-02 Total Dose (krad(Si)) 20 30 -3.70E-02 -3.68E-02 -3.58E-02 -3.57E-02 -3.56E-02 -3.55E-02 -3.63E-02 -3.61E-02 -3.67E-02 -3.66E-02 -3.59E-02 -3.57E-02 -3.57E-02 -3.55E-02 -3.72E-02 -3.69E-02 -3.49E-02 -3.47E-02 -3.61E-02 -3.59E-02 -3.72E-02 -3.74E-02 -3.86E-02 -3.84E-02 10 -3.73E-02 -3.60E-02 -3.60E-02 -3.67E-02 -3.72E-02 -3.62E-02 -3.60E-02 -3.73E-02 -3.50E-02 -3.63E-02 -3.72E-02 -3.84E-02 50 -3.59E-02 -3.49E-02 -3.48E-02 -3.53E-02 -3.57E-02 -3.47E-02 -3.45E-02 -3.58E-02 -3.37E-02 -3.49E-02 -3.69E-02 -3.81E-02 24 Hr Anneal 60 -3.59E-02 -3.47E-02 -3.45E-02 -3.52E-02 -3.57E-02 -3.47E-02 -3.45E-02 -3.58E-02 -3.37E-02 -3.48E-02 -3.69E-02 -3.79E-02 168 Hr Anneal 70 -3.65E-02 -3.55E-02 -3.53E-02 -3.59E-02 -3.64E-02 -3.53E-02 -3.50E-02 -3.64E-02 -3.43E-02 -3.54E-02 -3.71E-02 -3.82E-02 -3.71E-02 -3.66E-02 -3.63E-02 -3.61E-02 -3.53E-02 -3.52E-02 -3.59E-02 5.71E-04 6.42E-04 5.82E-04 5.58E-04 4.98E-04 5.74E-04 5.26E-04 -3.55E-02 -3.49E-02 -3.47E-02 -3.46E-02 -3.40E-02 -3.36E-02 -3.45E-02 -3.87E-02 -3.84E-02 -3.79E-02 -3.77E-02 -3.67E-02 -3.68E-02 -3.74E-02 -3.64E-02 8.34E-04 -3.41E-02 -3.87E-02 -1.50E-02 PASS -3.62E-02 8.15E-04 -3.39E-02 -3.84E-02 -1.00E-02 PASS -3.60E-02 8.05E-04 -3.38E-02 -3.82E-02 -1.00E-02 PASS -3.57E-02 7.81E-04 -3.36E-02 -3.79E-02 -1.00E-02 PASS -3.47E-02 7.67E-04 -3.26E-02 -3.68E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 208 -3.47E-02 7.57E-04 -3.26E-02 -3.68E-02 -1.00E-02 PASS -3.53E-02 7.64E-04 -3.32E-02 -3.74E-02 -1.00E-02 PASS ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 7.00E-02 -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.99. Plot of -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 209 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.99. Raw data for -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr -Short-Circuit Current1 1 15V (A) Anneal Anneal Total Dose (krad(Si)) @ VS=+/-15V, VOUT=0V Device 0 10 20 30 50 60 70 557 5.83E-02 5.84E-02 5.83E-02 5.81E-02 5.86E-02 5.87E-02 5.85E-02 563 5.88E-02 5.90E-02 5.87E-02 5.85E-02 5.89E-02 5.92E-02 5.88E-02 564 5.81E-02 5.79E-02 5.78E-02 5.75E-02 5.79E-02 5.83E-02 5.79E-02 567 5.81E-02 5.77E-02 5.77E-02 5.76E-02 5.81E-02 5.83E-02 5.80E-02 569 5.88E-02 5.85E-02 5.86E-02 5.84E-02 5.90E-02 5.91E-02 5.88E-02 570 5.81E-02 5.80E-02 5.79E-02 5.77E-02 5.83E-02 5.83E-02 5.81E-02 571 5.79E-02 5.80E-02 5.78E-02 5.76E-02 5.81E-02 5.82E-02 5.80E-02 572 5.73E-02 5.76E-02 5.72E-02 5.71E-02 5.76E-02 5.77E-02 5.75E-02 573 5.75E-02 5.78E-02 5.73E-02 5.72E-02 5.77E-02 5.78E-02 5.76E-02 574 5.80E-02 5.80E-02 5.77E-02 5.75E-02 5.80E-02 5.82E-02 5.79E-02 584 5.82E-02 5.80E-02 5.80E-02 5.78E-02 5.85E-02 5.86E-02 5.82E-02 585 5.79E-02 5.77E-02 5.74E-02 5.77E-02 5.82E-02 5.86E-02 5.80E-02 Biased Statistics Average Biased 5.84E-02 5.83E-02 5.82E-02 5.80E-02 5.85E-02 5.87E-02 5.84E-02 Std Dev Biased 3.67E-04 5.16E-04 4.58E-04 4.46E-04 4.82E-04 4.45E-04 4.12E-04 Ps90%/90% (+KTL) Biased 5.94E-02 5.97E-02 5.95E-02 5.93E-02 5.98E-02 5.99E-02 5.95E-02 Ps90%/90% (-KTL) Biased 5.74E-02 5.69E-02 5.70E-02 5.68E-02 5.71E-02 5.75E-02 5.73E-02 Un-Biased Statistics Average Un-Biased 5.77E-02 5.79E-02 5.76E-02 5.74E-02 5.79E-02 5.80E-02 5.78E-02 Std Dev Un-Biased 3.58E-04 1.96E-04 3.07E-04 2.74E-04 3.04E-04 2.61E-04 2.90E-04 Ps90%/90% (+KTL) Un-Biased 5.87E-02 5.84E-02 5.84E-02 5.82E-02 5.88E-02 5.88E-02 5.86E-02 Ps90%/90% (-KTL) Un-Biased 5.68E-02 5.73E-02 5.67E-02 5.67E-02 5.71E-02 5.73E-02 5.70E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 210 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.100. Plot of -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 211 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.100. Raw data for -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr -Short-Circuit Current1 2 15V (A) Anneal Anneal Total Dose (krad(Si)) @ VS=+/-15V, VOUT=0V Device 0 10 20 30 50 60 70 557 5.73E-02 5.74E-02 5.73E-02 5.71E-02 5.76E-02 5.77E-02 5.75E-02 563 5.65E-02 5.67E-02 5.64E-02 5.62E-02 5.66E-02 5.69E-02 5.64E-02 564 5.64E-02 5.61E-02 5.60E-02 5.58E-02 5.61E-02 5.66E-02 5.62E-02 567 5.68E-02 5.65E-02 5.65E-02 5.64E-02 5.69E-02 5.71E-02 5.68E-02 569 5.62E-02 5.58E-02 5.59E-02 5.58E-02 5.63E-02 5.64E-02 5.61E-02 570 5.65E-02 5.65E-02 5.63E-02 5.61E-02 5.68E-02 5.68E-02 5.66E-02 571 5.63E-02 5.64E-02 5.62E-02 5.60E-02 5.65E-02 5.65E-02 5.64E-02 572 5.66E-02 5.69E-02 5.65E-02 5.64E-02 5.69E-02 5.71E-02 5.68E-02 573 5.59E-02 5.61E-02 5.57E-02 5.55E-02 5.61E-02 5.62E-02 5.59E-02 574 5.69E-02 5.70E-02 5.67E-02 5.65E-02 5.70E-02 5.72E-02 5.69E-02 584 5.62E-02 5.61E-02 5.61E-02 5.59E-02 5.65E-02 5.66E-02 5.62E-02 585 5.64E-02 5.62E-02 5.60E-02 5.62E-02 5.67E-02 5.70E-02 5.65E-02 Biased Statistics Average Biased 5.66E-02 5.65E-02 5.64E-02 5.63E-02 5.67E-02 5.69E-02 5.66E-02 Std Dev Biased 4.48E-04 5.86E-04 5.51E-04 5.39E-04 5.65E-04 5.04E-04 5.60E-04 Ps90%/90% (+KTL) Biased 5.79E-02 5.81E-02 5.79E-02 5.78E-02 5.82E-02 5.83E-02 5.81E-02 Ps90%/90% (-KTL) Biased 5.54E-02 5.49E-02 5.49E-02 5.48E-02 5.51E-02 5.55E-02 5.51E-02 Un-Biased Statistics Average Un-Biased 5.64E-02 5.66E-02 5.63E-02 5.61E-02 5.66E-02 5.67E-02 5.65E-02 Std Dev Un-Biased 3.86E-04 3.61E-04 3.63E-04 3.83E-04 3.65E-04 4.18E-04 3.85E-04 Ps90%/90% (+KTL) Un-Biased 5.75E-02 5.76E-02 5.73E-02 5.72E-02 5.76E-02 5.79E-02 5.76E-02 Ps90%/90% (-KTL) Un-Biased 5.54E-02 5.56E-02 5.53E-02 5.51E-02 5.56E-02 5.56E-02 5.55E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 212 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.101. Plot of -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 213 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.101. Raw data for -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr -Short-Circuit Current1 3 15V (A) Anneal Anneal Total Dose (krad(Si)) @ VS=+/-15V, VOUT=0V Device 0 10 20 30 50 60 70 557 5.73E-02 5.74E-02 5.73E-02 5.72E-02 5.76E-02 5.78E-02 5.74E-02 563 5.66E-02 5.68E-02 5.65E-02 5.63E-02 5.67E-02 5.69E-02 5.66E-02 564 5.64E-02 5.62E-02 5.61E-02 5.59E-02 5.62E-02 5.66E-02 5.62E-02 567 5.68E-02 5.65E-02 5.65E-02 5.64E-02 5.69E-02 5.70E-02 5.68E-02 569 5.61E-02 5.57E-02 5.58E-02 5.57E-02 5.62E-02 5.64E-02 5.60E-02 570 5.68E-02 5.67E-02 5.66E-02 5.64E-02 5.70E-02 5.70E-02 5.68E-02 571 5.66E-02 5.67E-02 5.65E-02 5.63E-02 5.68E-02 5.68E-02 5.67E-02 572 5.68E-02 5.71E-02 5.67E-02 5.66E-02 5.71E-02 5.72E-02 5.70E-02 573 5.58E-02 5.62E-02 5.57E-02 5.56E-02 5.61E-02 5.62E-02 5.60E-02 574 5.71E-02 5.72E-02 5.69E-02 5.67E-02 5.72E-02 5.74E-02 5.71E-02 584 5.64E-02 5.62E-02 5.62E-02 5.60E-02 5.67E-02 5.67E-02 5.64E-02 585 5.66E-02 5.63E-02 5.61E-02 5.64E-02 5.68E-02 5.72E-02 5.66E-02 Biased Statistics Average Biased 5.66E-02 5.65E-02 5.64E-02 5.63E-02 5.67E-02 5.69E-02 5.66E-02 Std Dev Biased 4.59E-04 6.26E-04 5.73E-04 5.65E-04 5.80E-04 5.32E-04 5.63E-04 Ps90%/90% (+KTL) Biased 5.79E-02 5.82E-02 5.80E-02 5.78E-02 5.83E-02 5.84E-02 5.81E-02 Ps90%/90% (-KTL) Biased 5.54E-02 5.48E-02 5.49E-02 5.47E-02 5.51E-02 5.55E-02 5.50E-02 Un-Biased Statistics Average Un-Biased 5.66E-02 5.68E-02 5.65E-02 5.63E-02 5.68E-02 5.69E-02 5.67E-02 Std Dev Un-Biased 4.84E-04 4.03E-04 4.43E-04 4.33E-04 4.44E-04 4.60E-04 4.42E-04 Ps90%/90% (+KTL) Un-Biased 5.79E-02 5.79E-02 5.77E-02 5.75E-02 5.80E-02 5.82E-02 5.79E-02 Ps90%/90% (-KTL) Un-Biased 5.53E-02 5.57E-02 5.53E-02 5.51E-02 5.56E-02 5.57E-02 5.55E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 214 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.102. Plot of -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 215 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.102. Raw data for -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr -Short-Circuit Current1 4 15V (A) Anneal Anneal Total Dose (krad(Si)) @ VS=+/-15V, VOUT=0V Device 0 10 20 30 50 60 70 557 5.59E-02 5.60E-02 5.60E-02 5.58E-02 5.62E-02 5.63E-02 5.61E-02 563 5.65E-02 5.67E-02 5.64E-02 5.62E-02 5.65E-02 5.69E-02 5.64E-02 564 5.58E-02 5.55E-02 5.54E-02 5.52E-02 5.55E-02 5.60E-02 5.56E-02 567 5.56E-02 5.53E-02 5.53E-02 5.52E-02 5.57E-02 5.58E-02 5.56E-02 569 5.65E-02 5.61E-02 5.62E-02 5.61E-02 5.66E-02 5.67E-02 5.63E-02 570 5.57E-02 5.56E-02 5.55E-02 5.53E-02 5.59E-02 5.59E-02 5.57E-02 571 5.55E-02 5.56E-02 5.54E-02 5.52E-02 5.57E-02 5.57E-02 5.56E-02 572 5.51E-02 5.54E-02 5.50E-02 5.49E-02 5.54E-02 5.55E-02 5.53E-02 573 5.51E-02 5.54E-02 5.50E-02 5.48E-02 5.53E-02 5.54E-02 5.52E-02 574 5.56E-02 5.56E-02 5.54E-02 5.53E-02 5.56E-02 5.59E-02 5.56E-02 584 5.57E-02 5.55E-02 5.55E-02 5.53E-02 5.60E-02 5.60E-02 5.57E-02 585 5.54E-02 5.51E-02 5.49E-02 5.51E-02 5.56E-02 5.59E-02 5.54E-02 Biased Statistics Average Biased 5.61E-02 5.59E-02 5.59E-02 5.57E-02 5.61E-02 5.63E-02 5.60E-02 Std Dev Biased 4.01E-04 5.37E-04 4.72E-04 4.55E-04 4.90E-04 4.68E-04 4.16E-04 Ps90%/90% (+KTL) Biased 5.72E-02 5.74E-02 5.72E-02 5.69E-02 5.74E-02 5.76E-02 5.71E-02 Ps90%/90% (-KTL) Biased 5.50E-02 5.45E-02 5.46E-02 5.44E-02 5.48E-02 5.51E-02 5.49E-02 Un-Biased Statistics Average Un-Biased 5.54E-02 5.55E-02 5.53E-02 5.51E-02 5.56E-02 5.57E-02 5.55E-02 Std Dev Un-Biased 2.85E-04 1.31E-04 2.45E-04 2.32E-04 2.50E-04 2.27E-04 2.25E-04 Ps90%/90% (+KTL) Un-Biased 5.62E-02 5.59E-02 5.59E-02 5.57E-02 5.63E-02 5.63E-02 5.61E-02 Ps90%/90% (-KTL) Un-Biased 5.46E-02 5.52E-02 5.46E-02 5.45E-02 5.49E-02 5.51E-02 5.49E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 216 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased +Supply Current 5V (A) @ VS=+5V 9.00E-03 8.80E-03 8.60E-03 8.40E-03 8.20E-03 8.00E-03 7.80E-03 7.60E-03 7.40E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.103. Plot of +Supply Current 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 217 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.103. Raw data for +Supply Current 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Supply Current 5V (A) @ VS=+5V Device 557 563 564 567 569 570 571 572 573 574 584 585 0 7.72E-03 7.79E-03 7.79E-03 7.73E-03 7.73E-03 7.72E-03 7.63E-03 7.79E-03 7.58E-03 7.71E-03 7.70E-03 7.76E-03 10 7.70E-03 7.75E-03 7.77E-03 7.72E-03 7.71E-03 7.71E-03 7.60E-03 7.76E-03 7.57E-03 7.69E-03 7.71E-03 7.76E-03 Total Dose (krad(Si)) 20 30 7.68E-03 7.67E-03 7.74E-03 7.74E-03 7.75E-03 7.76E-03 7.69E-03 7.69E-03 7.68E-03 7.67E-03 7.69E-03 7.68E-03 7.59E-03 7.59E-03 7.75E-03 7.74E-03 7.55E-03 7.54E-03 7.69E-03 7.67E-03 7.71E-03 7.71E-03 7.80E-03 7.76E-03 50 7.62E-03 7.68E-03 7.70E-03 7.63E-03 7.62E-03 7.61E-03 7.53E-03 7.67E-03 7.47E-03 7.61E-03 7.68E-03 7.74E-03 24 Hr Anneal 60 7.61E-03 7.67E-03 7.68E-03 7.62E-03 7.61E-03 7.61E-03 7.51E-03 7.66E-03 7.47E-03 7.60E-03 7.66E-03 7.71E-03 168 Hr Anneal 70 7.63E-03 7.71E-03 7.72E-03 7.65E-03 7.64E-03 7.64E-03 7.53E-03 7.69E-03 7.49E-03 7.63E-03 7.68E-03 7.74E-03 Biased Statistics Average Biased 7.75E-03 7.73E-03 7.71E-03 7.71E-03 7.65E-03 7.64E-03 7.67E-03 Std Dev Biased 3.57E-05 3.01E-05 3.44E-05 4.03E-05 3.90E-05 3.56E-05 4.13E-05 Ps90%/90% (+KTL) Biased 7.85E-03 7.81E-03 7.80E-03 7.82E-03 7.75E-03 7.73E-03 7.78E-03 Ps90%/90% (-KTL) Biased 7.65E-03 7.65E-03 7.61E-03 7.60E-03 7.54E-03 7.54E-03 7.56E-03 Un-Biased Statistics Average Un-Biased 7.69E-03 7.67E-03 7.65E-03 7.64E-03 7.58E-03 7.57E-03 7.60E-03 Std Dev Un-Biased 8.32E-05 8.14E-05 8.18E-05 8.03E-05 7.98E-05 8.07E-05 8.26E-05 Ps90%/90% (+KTL) Un-Biased 7.91E-03 7.89E-03 7.88E-03 7.86E-03 7.80E-03 7.79E-03 7.82E-03 Ps90%/90% (-KTL) Un-Biased 7.46E-03 7.44E-03 7.43E-03 7.42E-03 7.36E-03 7.35E-03 7.37E-03 Specification MAX 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 218 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased -7.40E-03 -Supply Current 5V (A) @ VS=+5V -7.60E-03 -7.80E-03 -8.00E-03 -8.20E-03 -8.40E-03 -8.60E-03 -8.80E-03 -9.00E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.104. Plot of -Supply Current 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 219 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.104. Raw data for -Supply Current 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Supply Current 5V (A) @ VS=+5V Device 557 563 564 567 569 570 571 572 573 574 584 585 0 -7.72E-03 -7.79E-03 -7.79E-03 -7.73E-03 -7.72E-03 -7.72E-03 -7.62E-03 -7.78E-03 -7.58E-03 -7.71E-03 -7.70E-03 -7.76E-03 Biased Statistics Average Biased -7.75E-03 Std Dev Biased 3.60E-05 Ps90%/90% (+KTL) Biased -7.65E-03 Ps90%/90% (-KTL) Biased -7.85E-03 Un-Biased Statistics Average Un-Biased -7.68E-03 Std Dev Un-Biased 8.20E-05 Ps90%/90% (+KTL) Un-Biased -7.46E-03 Ps90%/90% (-KTL) Un-Biased -7.91E-03 Specification MIN -8.80E-03 Status PASS 10 -7.69E-03 -7.75E-03 -7.77E-03 -7.72E-03 -7.70E-03 -7.71E-03 -7.60E-03 -7.76E-03 -7.56E-03 -7.68E-03 -7.71E-03 -7.75E-03 Total Dose (krad(Si)) 20 30 -7.68E-03 -7.67E-03 -7.74E-03 -7.73E-03 -7.75E-03 -7.75E-03 -7.69E-03 -7.68E-03 -7.68E-03 -7.67E-03 -7.69E-03 -7.68E-03 -7.59E-03 -7.58E-03 -7.75E-03 -7.74E-03 -7.55E-03 -7.54E-03 -7.69E-03 -7.67E-03 -7.71E-03 -7.72E-03 -7.80E-03 -7.76E-03 50 -7.61E-03 -7.68E-03 -7.70E-03 -7.62E-03 -7.61E-03 -7.61E-03 -7.53E-03 -7.67E-03 -7.47E-03 -7.61E-03 -7.68E-03 -7.74E-03 24 Hr Anneal 60 -7.61E-03 -7.67E-03 -7.67E-03 -7.61E-03 -7.60E-03 -7.61E-03 -7.51E-03 -7.66E-03 -7.46E-03 -7.60E-03 -7.66E-03 -7.71E-03 168 Hr Anneal 70 -7.63E-03 -7.71E-03 -7.72E-03 -7.64E-03 -7.64E-03 -7.63E-03 -7.53E-03 -7.69E-03 -7.48E-03 -7.62E-03 -7.68E-03 -7.74E-03 -7.72E-03 -7.70E-03 -7.70E-03 -7.64E-03 -7.63E-03 -7.67E-03 3.07E-05 3.42E-05 3.98E-05 3.95E-05 3.53E-05 4.11E-05 -7.64E-03 -7.61E-03 -7.59E-03 -7.54E-03 -7.54E-03 -7.56E-03 -7.81E-03 -7.80E-03 -7.81E-03 -7.75E-03 -7.73E-03 -7.78E-03 -7.66E-03 8.05E-05 -7.44E-03 -7.88E-03 -8.80E-03 PASS -7.65E-03 8.06E-05 -7.43E-03 -7.87E-03 -8.80E-03 PASS -7.64E-03 8.02E-05 -7.42E-03 -7.86E-03 -8.80E-03 PASS -7.58E-03 7.90E-05 -7.36E-03 -7.79E-03 -8.80E-03 PASS An ISO 9001:2008 and DSCC Certified Company 220 -7.57E-03 7.99E-05 -7.35E-03 -7.79E-03 -8.80E-03 PASS -7.59E-03 8.15E-05 -7.37E-03 -7.82E-03 -8.80E-03 PASS Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.105. Plot of Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 221 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.105. Raw data for Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.97E-04 -7.81E-05 4.79E-05 5.03E-05 -1.40E-04 1.82E-04 -2.52E-04 2.48E-04 8.94E-05 -7.19E-06 -3.53E-04 1.81E-04 10 -2.05E-04 -8.42E-05 3.98E-05 4.15E-05 -1.44E-04 1.71E-04 -2.58E-04 2.35E-04 8.42E-05 -1.59E-05 -3.53E-04 1.75E-04 Total Dose (krad(Si)) 20 30 -2.07E-04 -2.11E-04 -8.65E-05 -8.74E-05 4.09E-05 4.26E-05 3.76E-05 3.93E-05 -1.47E-04 -1.47E-04 1.68E-04 1.66E-04 -2.60E-04 -2.62E-04 2.33E-04 2.33E-04 8.18E-05 7.99E-05 -1.37E-05 -1.65E-05 -3.54E-04 -3.54E-04 1.81E-04 1.77E-04 50 -2.17E-04 -9.49E-05 3.34E-05 3.93E-05 -1.51E-04 1.57E-04 -2.68E-04 2.28E-04 7.30E-05 -2.70E-05 -3.55E-04 1.75E-04 24 Hr Anneal 60 -2.15E-04 -9.35E-05 3.12E-05 3.76E-05 -1.52E-04 1.54E-04 -2.67E-04 2.24E-04 7.06E-05 -2.69E-05 -3.58E-04 1.71E-04 168 Hr Anneal 70 -2.11E-04 -1.09E-04 3.53E-05 3.47E-05 -1.50E-04 1.59E-04 -2.71E-04 2.22E-04 6.11E-05 -2.66E-05 -3.57E-04 1.75E-04 -6.34E-05 -7.06E-05 -7.25E-05 -7.27E-05 -7.80E-05 -7.83E-05 -7.99E-05 1.11E-04 1.10E-04 1.10E-04 1.13E-04 1.13E-04 1.11E-04 1.11E-04 2.41E-04 2.32E-04 2.30E-04 2.36E-04 2.32E-04 2.27E-04 2.24E-04 -3.68E-04 -3.73E-04 -3.75E-04 -3.81E-04 -3.88E-04 -3.84E-04 -3.84E-04 5.21E-05 1.95E-04 5.87E-04 -4.83E-04 -8.00E-04 PASS 8.00E-04 PASS 4.32E-05 1.93E-04 5.73E-04 -4.86E-04 -9.50E-04 PASS 9.50E-04 PASS 4.19E-05 1.93E-04 5.70E-04 -4.86E-04 -9.50E-04 PASS 9.50E-04 PASS 4.01E-05 1.93E-04 5.69E-04 -4.89E-04 -9.50E-04 PASS 9.50E-04 PASS 3.26E-05 1.93E-04 5.62E-04 -4.96E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 222 3.09E-05 1.91E-04 5.54E-04 -4.93E-04 -9.50E-04 PASS 9.50E-04 PASS 2.91E-05 1.93E-04 5.57E-04 -4.99E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.106. Plot of Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 223 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.106. Raw data for Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.64E-04 -1.81E-04 1.65E-05 -9.45E-05 -1.82E-05 4.40E-06 1.49E-04 4.59E-05 -7.76E-05 6.20E-05 -2.91E-04 9.88E-05 10 -1.71E-04 -1.89E-04 9.83E-06 -9.73E-05 -1.95E-05 -3.45E-06 1.43E-04 3.05E-05 -8.36E-05 5.49E-05 -2.92E-04 9.35E-05 Total Dose (krad(Si)) 20 30 -1.72E-04 -1.71E-04 -1.89E-04 -1.92E-04 1.12E-05 1.20E-05 -9.94E-05 -9.73E-05 -2.10E-05 -2.04E-05 -4.54E-06 -5.62E-06 1.43E-04 1.46E-04 2.96E-05 2.76E-05 -8.25E-05 -8.48E-05 5.51E-05 5.43E-05 -2.95E-04 -2.93E-04 9.48E-05 9.27E-05 50 -1.72E-04 -1.93E-04 3.44E-06 -1.05E-04 -1.99E-05 -7.91E-06 1.42E-04 2.42E-05 -8.33E-05 4.62E-05 -2.93E-04 9.88E-05 24 Hr Anneal 60 -1.72E-04 -1.89E-04 6.58E-06 -1.07E-04 -2.07E-05 -9.60E-06 1.43E-04 2.37E-05 -8.49E-05 4.97E-05 -2.89E-04 9.06E-05 168 Hr Anneal 70 -1.79E-04 -1.84E-04 1.27E-05 -8.70E-05 -2.61E-05 -6.83E-06 1.28E-04 2.05E-05 -9.13E-05 4.96E-05 -2.91E-04 9.53E-05 -8.83E-05 -9.33E-05 -9.40E-05 -9.37E-05 -9.74E-05 -9.65E-05 -9.26E-05 8.70E-05 8.83E-05 8.87E-05 8.97E-05 8.81E-05 8.77E-05 8.85E-05 1.50E-04 1.49E-04 1.49E-04 1.52E-04 1.44E-04 1.44E-04 1.50E-04 -3.27E-04 -3.35E-04 -3.37E-04 -3.40E-04 -3.39E-04 -3.37E-04 -3.35E-04 3.68E-05 8.28E-05 2.64E-04 -1.90E-04 -8.00E-04 PASS 8.00E-04 PASS 2.83E-05 8.29E-05 2.56E-04 -1.99E-04 -9.50E-04 PASS 9.50E-04 PASS 2.81E-05 8.24E-05 2.54E-04 -1.98E-04 -9.50E-04 PASS 9.50E-04 PASS 2.74E-05 8.43E-05 2.59E-04 -2.04E-04 -9.50E-04 PASS 9.50E-04 PASS 2.43E-05 8.22E-05 2.50E-04 -2.01E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 224 2.43E-05 8.33E-05 2.53E-04 -2.04E-04 -9.50E-04 PASS 9.50E-04 PASS 1.99E-05 7.99E-05 2.39E-04 -1.99E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.107. Plot of Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 225 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.107. Raw data for Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 3.74E-04 -7.14E-05 2.52E-05 5.23E-05 -9.87E-05 -1.65E-04 -1.90E-07 2.74E-04 1.74E-04 5.02E-05 4.19E-04 8.34E-05 10 3.64E-04 -7.67E-05 2.03E-05 5.08E-05 -1.03E-04 -1.72E-04 -9.97E-06 2.65E-04 1.70E-04 4.52E-05 4.22E-04 8.19E-05 Total Dose (krad(Si)) 20 30 3.60E-04 3.53E-04 -7.95E-05 -8.57E-05 1.39E-05 1.25E-05 4.52E-05 4.04E-05 -1.07E-04 -1.13E-04 -1.74E-04 -1.75E-04 -1.25E-05 -1.72E-05 2.60E-04 2.54E-04 1.69E-04 1.68E-04 4.24E-05 3.78E-05 4.21E-04 4.21E-04 7.95E-05 7.66E-05 50 3.45E-04 -8.25E-05 5.97E-06 3.83E-05 -1.14E-04 -1.80E-04 -2.47E-05 2.45E-04 1.59E-04 3.17E-05 4.20E-04 8.17E-05 24 Hr Anneal 60 3.43E-04 -8.25E-05 2.47E-06 3.62E-05 -1.22E-04 -1.82E-04 -2.45E-05 2.44E-04 1.60E-04 3.04E-05 4.17E-04 7.21E-05 168 Hr Anneal 70 3.41E-04 -7.89E-05 -3.33E-06 3.28E-05 -1.12E-04 -1.77E-04 -1.21E-05 2.34E-04 1.57E-04 2.49E-05 4.19E-04 7.84E-05 5.64E-05 5.10E-05 4.65E-05 4.15E-05 3.86E-05 3.54E-05 3.59E-05 1.89E-04 1.86E-04 1.86E-04 1.85E-04 1.82E-04 1.83E-04 1.80E-04 5.74E-04 5.61E-04 5.58E-04 5.50E-04 5.38E-04 5.38E-04 5.30E-04 -4.61E-04 -4.59E-04 -4.65E-04 -4.67E-04 -4.61E-04 -4.67E-04 -4.58E-04 6.66E-05 1.68E-04 5.28E-04 -3.95E-04 -8.00E-04 PASS 8.00E-04 PASS 5.97E-05 1.68E-04 5.20E-04 -4.01E-04 -9.50E-04 PASS 9.50E-04 PASS 5.70E-05 1.67E-04 5.16E-04 -4.02E-04 -9.50E-04 PASS 9.50E-04 PASS 5.35E-05 1.66E-04 5.10E-04 -4.03E-04 -9.50E-04 PASS 9.50E-04 PASS 4.62E-05 1.65E-04 4.98E-04 -4.06E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 226 4.57E-05 1.65E-04 4.99E-04 -4.07E-04 -9.50E-04 PASS 9.50E-04 PASS 4.52E-05 1.59E-04 4.81E-04 -3.90E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.108. Plot of Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 227 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.108. Raw data for Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 8.92E-06 7.00E-05 1.88E-04 1.99E-04 -2.09E-04 1.41E-04 1.75E-04 3.74E-05 1.41E-04 -2.16E-04 2.38E-04 -1.22E-04 10 -1.16E-06 6.11E-05 1.83E-04 1.94E-04 -2.12E-04 1.30E-04 1.67E-04 2.60E-05 1.34E-04 -2.23E-04 2.37E-04 -1.22E-04 Total Dose (krad(Si)) 20 30 -3.45E-06 -4.90E-06 5.88E-05 5.98E-05 1.85E-04 1.84E-04 1.94E-04 1.95E-04 -2.14E-04 -2.19E-04 1.30E-04 1.32E-04 1.69E-04 1.66E-04 2.25E-05 2.28E-05 1.37E-04 1.40E-04 -2.22E-04 -2.22E-04 2.38E-04 2.38E-04 -1.21E-04 -1.20E-04 50 -1.03E-05 5.36E-05 1.75E-04 1.89E-04 -2.14E-04 1.37E-04 1.63E-04 1.65E-05 1.40E-04 -2.21E-04 2.34E-04 -1.21E-04 24 Hr Anneal 60 -1.19E-05 5.05E-05 1.70E-04 1.86E-04 -2.16E-04 1.33E-04 1.59E-04 1.46E-05 1.35E-04 -2.23E-04 2.30E-04 -1.24E-04 168 Hr Anneal 70 -6.35E-06 6.13E-05 1.75E-04 1.87E-04 -2.13E-04 1.29E-04 1.63E-04 2.08E-05 1.26E-04 -2.33E-04 2.34E-04 -1.22E-04 5.13E-05 4.50E-05 4.41E-05 4.29E-05 3.87E-05 3.58E-05 4.10E-05 1.66E-04 1.66E-04 1.67E-04 1.69E-04 1.64E-04 1.63E-04 1.63E-04 5.07E-04 5.00E-04 5.01E-04 5.06E-04 4.88E-04 4.84E-04 4.88E-04 -4.05E-04 -4.10E-04 -4.13E-04 -4.20E-04 -4.11E-04 -4.12E-04 -4.07E-04 5.56E-05 1.60E-04 4.95E-04 -3.84E-04 -8.00E-04 PASS 8.00E-04 PASS 4.68E-05 1.60E-04 4.86E-04 -3.92E-04 -9.50E-04 PASS 9.50E-04 PASS 4.72E-05 1.61E-04 4.87E-04 -3.93E-04 -9.50E-04 PASS 9.50E-04 PASS 4.81E-05 1.60E-04 4.88E-04 -3.92E-04 -9.50E-04 PASS 9.50E-04 PASS 4.71E-05 1.60E-04 4.87E-04 -3.93E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 228 4.35E-05 1.59E-04 4.80E-04 -3.93E-04 -9.50E-04 PASS 9.50E-04 PASS 4.12E-05 1.62E-04 4.86E-04 -4.03E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.109. Plot of Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 229 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.109. Raw data for Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.39E-09 -3.77E-09 3.00E-11 5.62E-09 1.96E-09 5.10E-10 -5.46E-09 2.93E-09 -1.83E-09 5.34E-09 -7.95E-09 1.96E-09 10 2.13E-09 -4.36E-09 -1.70E-10 5.36E-09 7.40E-10 3.70E-10 -5.73E-09 2.85E-09 -1.81E-09 5.08E-09 -8.68E-09 1.60E-10 Total Dose (krad(Si)) 20 30 1.30E-09 8.90E-10 -4.45E-09 -5.06E-09 -1.01E-09 -1.93E-09 4.73E-09 5.01E-09 1.40E-10 -7.20E-10 7.70E-10 7.60E-10 -6.33E-09 -6.59E-09 2.77E-09 3.26E-09 -1.98E-09 -1.94E-09 5.26E-09 4.76E-09 -9.01E-09 -9.38E-09 1.30E-10 1.20E-10 50 -3.00E-10 -6.30E-09 -3.25E-09 3.99E-09 -2.13E-09 7.60E-10 -6.70E-09 2.80E-09 -2.05E-09 5.49E-09 -9.57E-09 4.00E-11 24 Hr Anneal 60 -1.28E-09 -7.04E-09 -4.45E-09 3.68E-09 -2.59E-09 5.40E-10 -7.64E-09 2.00E-09 -3.22E-09 4.55E-09 -9.76E-09 -9.00E-11 168 Hr Anneal 70 2.80E-10 -5.72E-09 -2.63E-09 3.48E-09 -1.16E-09 5.50E-10 -6.39E-09 1.96E-09 -2.41E-09 5.35E-09 -9.83E-09 -2.50E-10 1.25E-09 7.40E-10 1.42E-10 -3.62E-10 -1.60E-09 -2.34E-09 -1.15E-09 3.45E-09 3.54E-09 3.35E-09 3.71E-09 3.81E-09 4.00E-09 3.41E-09 1.07E-08 1.04E-08 9.32E-09 9.81E-09 8.85E-09 8.63E-09 8.20E-09 -8.21E-09 -8.97E-09 -9.03E-09 -1.05E-08 -1.20E-08 -1.33E-08 -1.05E-08 2.98E-10 4.19E-09 1.18E-08 -1.12E-08 -6.50E-08 PASS 6.50E-08 PASS 1.52E-10 4.19E-09 1.16E-08 -1.13E-08 -6.50E-08 PASS 6.50E-08 PASS 9.80E-11 4.47E-09 1.24E-08 -1.22E-08 -6.50E-08 PASS 6.50E-08 PASS 5.00E-11 4.50E-09 1.24E-08 -1.23E-08 -6.50E-08 PASS 6.50E-08 PASS 6.00E-11 4.68E-09 1.29E-08 -1.28E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 230 -7.54E-10 4.77E-09 1.23E-08 -1.38E-08 -6.50E-08 PASS 6.50E-08 PASS -1.88E-10 4.45E-09 1.20E-08 -1.24E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.110. Plot of Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 231 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.110. Raw data for Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.81E-09 -2.27E-09 -2.33E-09 6.50E-10 2.72E-09 -1.63E-09 -1.60E-10 2.20E-09 1.46E-09 -1.14E-09 3.03E-09 2.51E-09 10 2.38E-09 -2.88E-09 -3.31E-09 -3.30E-10 2.78E-09 -1.53E-09 -8.60E-10 1.91E-09 1.08E-09 -1.25E-09 2.52E-09 7.50E-10 Total Dose (krad(Si)) 20 30 2.05E-09 1.68E-09 -3.24E-09 -3.88E-09 -4.18E-09 -4.80E-09 -1.80E-10 -7.90E-10 3.30E-09 2.80E-09 -2.10E-09 -1.94E-09 -8.80E-10 -1.20E-10 2.23E-09 1.94E-09 8.00E-10 8.30E-10 -1.55E-09 -1.52E-09 1.98E-09 1.74E-09 6.50E-10 6.20E-10 50 7.30E-10 -4.26E-09 -5.29E-09 -1.69E-09 2.65E-09 -2.62E-09 -1.29E-09 2.97E-09 1.00E-09 -1.32E-09 1.64E-09 6.00E-10 24 Hr Anneal 60 -2.10E-10 -5.31E-09 -6.13E-09 -2.16E-09 2.11E-09 -3.06E-09 -2.42E-09 1.84E-09 1.00E-10 -2.12E-09 1.41E-09 5.70E-10 168 Hr Anneal 70 4.50E-10 -4.16E-09 -4.67E-09 -1.76E-09 1.37E-09 -2.47E-09 -1.83E-09 2.16E-09 6.60E-10 -1.75E-09 1.22E-09 5.20E-10 3.16E-10 -2.72E-10 -4.50E-10 -9.98E-10 -1.57E-09 -2.34E-09 -1.75E-09 2.54E-09 2.85E-09 3.24E-09 3.33E-09 3.32E-09 3.45E-09 2.69E-09 7.28E-09 7.53E-09 8.44E-09 8.14E-09 7.54E-09 7.11E-09 5.62E-09 -6.65E-09 -8.07E-09 -9.34E-09 -1.01E-08 -1.07E-08 -1.18E-08 -9.13E-09 1.46E-10 1.65E-09 4.66E-09 -4.37E-09 -6.50E-08 PASS 6.50E-08 PASS -1.30E-10 1.53E-09 4.07E-09 -4.33E-09 -6.50E-08 PASS 6.50E-08 PASS -3.00E-10 1.79E-09 4.60E-09 -5.20E-09 -6.50E-08 PASS 6.50E-08 PASS -1.62E-10 1.61E-09 4.26E-09 -4.59E-09 -6.50E-08 PASS 6.50E-08 PASS -2.52E-10 2.22E-09 5.84E-09 -6.35E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 232 -1.13E-09 2.04E-09 4.47E-09 -6.74E-09 -6.50E-08 PASS 6.50E-08 PASS -6.46E-10 1.97E-09 4.76E-09 -6.05E-09 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.111. Plot of Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 233 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.111. Raw data for Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 10 4.73E-09 2.83E-09 4.55E-09 3.34E-09 3.99E-09 1.70E-09 1.15E-08 1.01E-08 7.50E-10 -7.10E-10 7.39E-09 6.22E-09 2.69E-09 1.66E-09 5.46E-09 4.37E-09 9.14E-09 7.97E-09 -1.70E-10 -1.23E-09 5.95E-09 4.83E-09 -9.40E-10 -3.33E-09 Total Dose (krad(Si)) 20 30 1.70E-09 3.40E-10 1.54E-09 3.90E-10 2.80E-10 -8.50E-10 8.22E-09 7.45E-09 -2.06E-09 -4.13E-09 5.05E-09 4.49E-09 4.20E-10 5.30E-10 3.47E-09 2.62E-09 7.10E-09 6.52E-09 -2.67E-09 -3.54E-09 3.44E-09 2.61E-09 -4.36E-09 -5.04E-09 50 -1.56E-09 -8.90E-10 -1.84E-09 6.40E-09 -5.63E-09 3.93E-09 -9.30E-10 2.10E-09 5.33E-09 -3.18E-09 2.01E-09 -5.68E-09 24 Hr Anneal 60 -2.08E-09 -1.85E-09 -2.01E-09 6.26E-09 -6.56E-09 3.00E-09 -1.81E-09 1.01E-09 4.88E-09 -4.08E-09 1.89E-09 -5.80E-09 168 Hr Anneal 70 -4.50E-10 -1.33E-09 -2.21E-09 6.65E-09 -4.48E-09 3.38E-09 -2.30E-10 1.86E-09 5.86E-09 -3.08E-09 1.79E-09 -5.77E-09 5.11E-09 3.45E-09 1.94E-09 6.40E-10 -7.04E-10 -1.25E-09 -3.64E-10 3.94E-09 4.03E-09 3.82E-09 4.23E-09 4.38E-09 4.64E-09 4.20E-09 1.59E-08 1.45E-08 1.24E-08 1.22E-08 1.13E-08 1.15E-08 1.11E-08 -5.69E-09 -7.61E-09 -8.54E-09 -1.10E-08 -1.27E-08 -1.40E-08 -1.19E-08 4.90E-09 3.71E-09 1.51E-08 -5.27E-09 -6.50E-08 PASS 6.50E-08 PASS 3.80E-09 3.66E-09 1.38E-08 -6.23E-09 -6.50E-08 PASS 6.50E-08 PASS 2.67E-09 3.86E-09 1.33E-08 -7.90E-09 -6.50E-08 PASS 6.50E-08 PASS 2.12E-09 3.87E-09 1.27E-08 -8.48E-09 -6.50E-08 PASS 6.50E-08 PASS 1.45E-09 3.49E-09 1.10E-08 -8.12E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 234 6.00E-10 3.60E-09 1.05E-08 -9.28E-09 -6.50E-08 PASS 6.50E-08 PASS 1.56E-09 3.41E-09 1.09E-08 -7.80E-09 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.112. Plot of Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 235 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.112. Raw data for Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.12E-09 -1.00E-09 1.42E-08 7.32E-09 -2.74E-09 4.05E-09 7.65E-09 7.90E-10 1.02E-08 2.44E-09 3.78E-09 -1.65E-09 10 -1.99E-09 -4.87E-09 1.00E-08 3.42E-09 -4.97E-09 8.70E-10 4.31E-09 -2.28E-09 7.08E-09 -4.40E-10 8.50E-10 -5.97E-09 Total Dose (krad(Si)) 20 30 -3.40E-09 -4.58E-09 -7.08E-09 -7.34E-09 6.98E-09 6.03E-09 1.16E-09 2.10E-10 -6.57E-09 -7.50E-09 -5.00E-10 -5.20E-10 3.14E-09 2.73E-09 -3.66E-09 -4.53E-09 6.28E-09 6.05E-09 -1.79E-09 -1.97E-09 -5.70E-10 -1.25E-09 -6.95E-09 -7.47E-09 50 -5.16E-09 -8.75E-09 4.88E-09 -1.07E-09 -8.09E-09 -1.01E-09 2.57E-09 -3.73E-09 5.41E-09 -2.70E-09 -1.73E-09 -8.06E-09 24 Hr Anneal 60 -5.89E-09 -1.02E-08 4.26E-09 -1.56E-09 -9.08E-09 -1.67E-09 1.36E-09 -4.75E-09 4.14E-09 -3.73E-09 -1.89E-09 -8.23E-09 168 Hr Anneal 70 -5.05E-09 -8.85E-09 5.46E-09 -7.20E-10 -9.07E-09 -9.50E-10 2.25E-09 -4.74E-09 5.62E-09 -3.26E-09 -2.12E-09 -8.19E-09 3.98E-09 3.26E-10 -1.78E-09 -2.64E-09 -3.64E-09 -4.50E-09 -3.65E-09 6.87E-09 6.41E-09 5.90E-09 5.76E-09 5.64E-09 5.94E-09 6.12E-09 2.28E-08 1.79E-08 1.44E-08 1.32E-08 1.18E-08 1.18E-08 1.31E-08 -1.49E-08 -1.72E-08 -1.79E-08 -1.84E-08 -1.91E-08 -2.08E-08 -2.04E-08 5.02E-09 3.84E-09 1.56E-08 -5.51E-09 -6.50E-08 PASS 6.50E-08 PASS 1.91E-09 3.76E-09 1.22E-08 -8.41E-09 -6.50E-08 PASS 6.50E-08 PASS 6.94E-10 3.99E-09 1.16E-08 -1.03E-08 -6.50E-08 PASS 6.50E-08 PASS 3.52E-10 4.13E-09 1.17E-08 -1.10E-08 -6.50E-08 PASS 6.50E-08 PASS 1.08E-10 3.81E-09 1.06E-08 -1.03E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 236 -9.30E-10 3.67E-09 9.14E-09 -1.10E-08 -6.50E-08 PASS 6.50E-08 PASS -2.16E-10 4.20E-09 1.13E-08 -1.17E-08 -6.50E-08 PASS 6.50E-08 PASS +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.113. Plot of +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 237 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.113. Raw data for +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.51E-07 -3.72E-07 -3.78E-07 -3.88E-07 -3.76E-07 -3.84E-07 -3.72E-07 -3.66E-07 -3.72E-07 -3.71E-07 -3.55E-07 -3.63E-07 10 -3.62E-07 -3.86E-07 -3.92E-07 -4.01E-07 -3.90E-07 -3.87E-07 -3.74E-07 -3.71E-07 -3.76E-07 -3.74E-07 -3.52E-07 -3.64E-07 Total Dose (krad(Si)) 20 30 -3.68E-07 -3.74E-07 -3.93E-07 -3.97E-07 -4.01E-07 -4.04E-07 -4.13E-07 -4.16E-07 -4.01E-07 -4.05E-07 -3.93E-07 -4.01E-07 -3.83E-07 -3.89E-07 -3.78E-07 -3.86E-07 -3.83E-07 -3.89E-07 -3.81E-07 -3.88E-07 -3.53E-07 -3.55E-07 -3.62E-07 -3.63E-07 50 -3.91E-07 -4.13E-07 -4.20E-07 -4.30E-07 -4.20E-07 -4.17E-07 -4.07E-07 -4.04E-07 -4.06E-07 -4.04E-07 -3.57E-07 -3.62E-07 24 Hr Anneal 60 -3.90E-07 -4.15E-07 -4.21E-07 -4.30E-07 -4.19E-07 -4.15E-07 -4.07E-07 -4.02E-07 -4.05E-07 -4.06E-07 -3.58E-07 -3.65E-07 168 Hr Anneal 70 -3.75E-07 -3.95E-07 -4.03E-07 -4.12E-07 -4.03E-07 -4.03E-07 -3.91E-07 -3.86E-07 -3.90E-07 -3.89E-07 -3.58E-07 -3.67E-07 -3.73E-07 -3.86E-07 -3.95E-07 -3.99E-07 -4.15E-07 -4.15E-07 -3.98E-07 1.36E-08 1.48E-08 1.69E-08 1.54E-08 1.48E-08 1.53E-08 1.40E-08 -3.36E-07 -3.45E-07 -3.49E-07 -3.57E-07 -3.74E-07 -3.73E-07 -3.59E-07 -4.10E-07 -4.27E-07 -4.42E-07 -4.42E-07 -4.55E-07 -4.57E-07 -4.36E-07 -3.73E-07 6.62E-09 -3.55E-07 -3.91E-07 -6.50E-07 PASS 6.50E-07 PASS -3.76E-07 6.38E-09 -3.59E-07 -3.94E-07 -7.00E-07 PASS 7.00E-07 PASS -3.84E-07 5.62E-09 -3.68E-07 -3.99E-07 -7.50E-07 PASS 7.50E-07 PASS -3.91E-07 5.78E-09 -3.75E-07 -4.06E-07 -7.50E-07 PASS 7.50E-07 PASS -4.08E-07 5.24E-09 -3.93E-07 -4.22E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 238 -4.07E-07 4.82E-09 -3.94E-07 -4.20E-07 -8.00E-07 PASS 8.00E-07 PASS -3.92E-07 6.22E-09 -3.75E-07 -4.09E-07 -8.00E-07 PASS 8.00E-07 PASS +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.114. Plot of +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 239 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.114. Raw data for +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.44E-07 -3.92E-07 -3.77E-07 -3.74E-07 -3.61E-07 -3.77E-07 -3.71E-07 -3.64E-07 -3.64E-07 -3.68E-07 -3.74E-07 -3.73E-07 10 -3.54E-07 -4.03E-07 -3.90E-07 -3.87E-07 -3.75E-07 -3.80E-07 -3.75E-07 -3.67E-07 -3.66E-07 -3.70E-07 -3.73E-07 -3.75E-07 Total Dose (krad(Si)) 20 30 -3.62E-07 -3.68E-07 -4.11E-07 -4.17E-07 -4.00E-07 -4.03E-07 -3.96E-07 -4.01E-07 -3.84E-07 -3.90E-07 -3.87E-07 -3.94E-07 -3.83E-07 -3.90E-07 -3.74E-07 -3.81E-07 -3.73E-07 -3.79E-07 -3.78E-07 -3.84E-07 -3.72E-07 -3.74E-07 -3.72E-07 -3.72E-07 50 -3.86E-07 -4.31E-07 -4.18E-07 -4.15E-07 -4.05E-07 -4.12E-07 -4.08E-07 -4.01E-07 -3.96E-07 -4.04E-07 -3.76E-07 -3.71E-07 24 Hr Anneal 60 -3.85E-07 -4.32E-07 -4.21E-07 -4.16E-07 -4.05E-07 -4.10E-07 -4.07E-07 -4.00E-07 -3.95E-07 -4.05E-07 -3.79E-07 -3.75E-07 168 Hr Anneal 70 -3.70E-07 -4.13E-07 -4.00E-07 -3.97E-07 -3.87E-07 -3.95E-07 -3.89E-07 -3.83E-07 -3.81E-07 -3.86E-07 -3.78E-07 -3.76E-07 -3.69E-07 -3.82E-07 -3.91E-07 -3.96E-07 -4.11E-07 -4.12E-07 -3.93E-07 1.81E-08 1.83E-08 1.89E-08 1.83E-08 1.68E-08 1.79E-08 1.63E-08 -3.20E-07 -3.32E-07 -3.39E-07 -3.46E-07 -3.65E-07 -3.63E-07 -3.49E-07 -4.19E-07 -4.32E-07 -4.42E-07 -4.46E-07 -4.57E-07 -4.61E-07 -4.38E-07 -3.69E-07 5.51E-09 -3.54E-07 -3.84E-07 -6.50E-07 PASS 6.50E-07 PASS -3.72E-07 5.68E-09 -3.56E-07 -3.87E-07 -7.00E-07 PASS 7.00E-07 PASS -3.79E-07 5.91E-09 -3.63E-07 -3.95E-07 -7.50E-07 PASS 7.50E-07 PASS -3.86E-07 6.28E-09 -3.68E-07 -4.03E-07 -7.50E-07 PASS 7.50E-07 PASS -4.04E-07 5.97E-09 -3.88E-07 -4.21E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 240 -4.03E-07 5.74E-09 -3.88E-07 -4.19E-07 -8.00E-07 PASS 8.00E-07 PASS -3.87E-07 5.62E-09 -3.71E-07 -4.02E-07 -8.00E-07 PASS 8.00E-07 PASS +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.115. Plot of +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 241 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.115. Raw data for +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.45E-07 -3.85E-07 -3.79E-07 -3.70E-07 -3.62E-07 -3.75E-07 -3.71E-07 -3.64E-07 -3.56E-07 -3.68E-07 -3.76E-07 -3.84E-07 10 -3.54E-07 -3.96E-07 -3.92E-07 -3.81E-07 -3.73E-07 -3.76E-07 -3.72E-07 -3.66E-07 -3.59E-07 -3.70E-07 -3.72E-07 -3.83E-07 Total Dose (krad(Si)) 20 30 -3.60E-07 -3.67E-07 -4.04E-07 -4.09E-07 -4.01E-07 -4.06E-07 -3.92E-07 -3.97E-07 -3.85E-07 -3.89E-07 -3.84E-07 -3.90E-07 -3.80E-07 -3.87E-07 -3.72E-07 -3.80E-07 -3.65E-07 -3.71E-07 -3.77E-07 -3.84E-07 -3.73E-07 -3.74E-07 -3.81E-07 -3.82E-07 50 -3.83E-07 -4.23E-07 -4.22E-07 -4.11E-07 -4.04E-07 -4.09E-07 -4.03E-07 -3.97E-07 -3.90E-07 -4.01E-07 -3.77E-07 -3.81E-07 24 Hr Anneal 60 -3.83E-07 -4.26E-07 -4.22E-07 -4.11E-07 -4.04E-07 -4.08E-07 -4.04E-07 -3.97E-07 -3.89E-07 -4.02E-07 -3.79E-07 -3.84E-07 168 Hr Anneal 70 -3.68E-07 -4.06E-07 -4.03E-07 -3.93E-07 -3.86E-07 -3.94E-07 -3.87E-07 -3.82E-07 -3.73E-07 -3.86E-07 -3.78E-07 -3.86E-07 -3.68E-07 -3.79E-07 -3.88E-07 -3.94E-07 -4.09E-07 -4.09E-07 -3.91E-07 1.58E-08 1.68E-08 1.76E-08 1.69E-08 1.64E-08 1.72E-08 1.53E-08 -3.25E-07 -3.33E-07 -3.40E-07 -3.47E-07 -3.64E-07 -3.62E-07 -3.50E-07 -4.12E-07 -4.25E-07 -4.37E-07 -4.40E-07 -4.53E-07 -4.56E-07 -4.33E-07 -3.67E-07 7.15E-09 -3.47E-07 -3.86E-07 -6.50E-07 PASS 6.50E-07 PASS -3.69E-07 6.78E-09 -3.50E-07 -3.87E-07 -7.00E-07 PASS 7.00E-07 PASS -3.76E-07 7.13E-09 -3.56E-07 -3.95E-07 -7.50E-07 PASS 7.50E-07 PASS -3.82E-07 7.38E-09 -3.62E-07 -4.03E-07 -7.50E-07 PASS 7.50E-07 PASS -4.00E-07 7.14E-09 -3.80E-07 -4.20E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 242 -4.00E-07 7.34E-09 -3.80E-07 -4.20E-07 -8.00E-07 PASS 8.00E-07 PASS -3.84E-07 7.74E-09 -3.63E-07 -4.06E-07 -8.00E-07 PASS 8.00E-07 PASS +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.116. Plot of +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 243 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.116. Raw data for +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.56E-07 -3.74E-07 -3.71E-07 -3.89E-07 -3.81E-07 -3.81E-07 -3.70E-07 -3.73E-07 -3.78E-07 -3.75E-07 -3.50E-07 -3.65E-07 10 -3.66E-07 -3.86E-07 -3.85E-07 -4.02E-07 -3.93E-07 -3.83E-07 -3.72E-07 -3.76E-07 -3.80E-07 -3.78E-07 -3.46E-07 -3.66E-07 Total Dose (krad(Si)) 20 30 -3.72E-07 -3.80E-07 -3.96E-07 -4.00E-07 -3.96E-07 -4.00E-07 -4.12E-07 -4.16E-07 -4.04E-07 -4.09E-07 -3.90E-07 -3.96E-07 -3.82E-07 -3.89E-07 -3.84E-07 -3.93E-07 -3.89E-07 -3.93E-07 -3.84E-07 -3.90E-07 -3.47E-07 -3.49E-07 -3.62E-07 -3.64E-07 50 -3.98E-07 -4.15E-07 -4.13E-07 -4.30E-07 -4.25E-07 -4.13E-07 -4.07E-07 -4.12E-07 -4.10E-07 -4.08E-07 -3.51E-07 -3.64E-07 24 Hr Anneal 60 -3.98E-07 -4.18E-07 -4.15E-07 -4.32E-07 -4.22E-07 -4.11E-07 -4.05E-07 -4.11E-07 -4.09E-07 -4.10E-07 -3.53E-07 -3.66E-07 168 Hr Anneal 70 -3.81E-07 -3.98E-07 -3.96E-07 -4.13E-07 -4.05E-07 -3.98E-07 -3.89E-07 -3.95E-07 -3.94E-07 -3.93E-07 -3.51E-07 -3.67E-07 -3.74E-07 -3.86E-07 -3.96E-07 -4.01E-07 -4.16E-07 -4.17E-07 -3.98E-07 1.21E-08 1.29E-08 1.48E-08 1.35E-08 1.24E-08 1.24E-08 1.19E-08 -3.41E-07 -3.51E-07 -3.55E-07 -3.64E-07 -3.82E-07 -3.83E-07 -3.66E-07 -4.07E-07 -4.22E-07 -4.36E-07 -4.38E-07 -4.50E-07 -4.51E-07 -4.31E-07 -3.75E-07 4.09E-09 -3.64E-07 -3.87E-07 -6.50E-07 PASS 6.50E-07 PASS -3.78E-07 3.96E-09 -3.67E-07 -3.89E-07 -7.00E-07 PASS 7.00E-07 PASS -3.86E-07 3.63E-09 -3.76E-07 -3.96E-07 -7.50E-07 PASS 7.50E-07 PASS -3.92E-07 2.69E-09 -3.85E-07 -3.99E-07 -7.50E-07 PASS 7.50E-07 PASS -4.10E-07 2.63E-09 -4.03E-07 -4.17E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 244 -4.09E-07 2.54E-09 -4.02E-07 -4.16E-07 -8.00E-07 PASS 8.00E-07 PASS -3.94E-07 3.11E-09 -3.85E-07 -4.02E-07 -8.00E-07 PASS 8.00E-07 PASS -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.117. Plot of -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 245 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.117. Raw data for -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.57E-07 -3.70E-07 -3.78E-07 -3.97E-07 -3.81E-07 -3.85E-07 -3.69E-07 -3.72E-07 -3.72E-07 -3.80E-07 -3.50E-07 -3.66E-07 10 -3.65E-07 -3.82E-07 -3.93E-07 -4.09E-07 -3.93E-07 -3.87E-07 -3.70E-07 -3.74E-07 -3.76E-07 -3.82E-07 -3.46E-07 -3.66E-07 Total Dose (krad(Si)) 20 30 -3.71E-07 -3.78E-07 -3.90E-07 -3.94E-07 -4.01E-07 -4.04E-07 -4.18E-07 -4.22E-07 -4.03E-07 -4.07E-07 -3.95E-07 -4.03E-07 -3.77E-07 -3.85E-07 -3.80E-07 -3.88E-07 -3.82E-07 -3.88E-07 -3.89E-07 -3.94E-07 -3.45E-07 -3.48E-07 -3.63E-07 -3.64E-07 50 -3.91E-07 -4.08E-07 -4.20E-07 -4.35E-07 -4.20E-07 -4.19E-07 -4.04E-07 -4.08E-07 -4.06E-07 -4.12E-07 -3.50E-07 -3.63E-07 24 Hr Anneal 60 -3.91E-07 -4.08E-07 -4.18E-07 -4.35E-07 -4.20E-07 -4.16E-07 -4.01E-07 -4.05E-07 -4.03E-07 -4.11E-07 -3.51E-07 -3.65E-07 168 Hr Anneal 70 -3.77E-07 -3.92E-07 -4.02E-07 -4.18E-07 -4.02E-07 -4.02E-07 -3.88E-07 -3.90E-07 -3.90E-07 -3.96E-07 -3.49E-07 -3.67E-07 -3.77E-07 -3.88E-07 -3.96E-07 -4.01E-07 -4.15E-07 -4.15E-07 -3.98E-07 1.47E-08 1.61E-08 1.72E-08 1.63E-08 1.62E-08 1.62E-08 1.50E-08 -3.36E-07 -3.44E-07 -3.49E-07 -3.56E-07 -3.70E-07 -3.70E-07 -3.57E-07 -4.17E-07 -4.33E-07 -4.44E-07 -4.46E-07 -4.59E-07 -4.59E-07 -4.39E-07 -3.75E-07 6.68E-09 -3.57E-07 -3.94E-07 -6.50E-07 PASS 6.50E-07 PASS -3.78E-07 6.91E-09 -3.59E-07 -3.97E-07 -7.00E-07 PASS 7.00E-07 PASS -3.85E-07 7.14E-09 -3.65E-07 -4.04E-07 -7.50E-07 PASS 7.50E-07 PASS -3.91E-07 7.04E-09 -3.72E-07 -4.11E-07 -7.50E-07 PASS 7.50E-07 PASS -4.10E-07 5.98E-09 -3.93E-07 -4.26E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 246 -4.07E-07 6.23E-09 -3.90E-07 -4.24E-07 -8.00E-07 PASS 8.00E-07 PASS -3.93E-07 5.96E-09 -3.77E-07 -4.10E-07 -8.00E-07 PASS 8.00E-07 PASS -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.118. Plot of -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 247 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.118. Raw data for -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.50E-07 -3.92E-07 -3.76E-07 -3.75E-07 -3.66E-07 -3.76E-07 -3.72E-07 -3.67E-07 -3.66E-07 -3.67E-07 -3.81E-07 -3.77E-07 10 -3.59E-07 -4.03E-07 -3.89E-07 -3.87E-07 -3.78E-07 -3.79E-07 -3.75E-07 -3.71E-07 -3.69E-07 -3.70E-07 -3.77E-07 -3.76E-07 Total Dose (krad(Si)) 20 30 -3.65E-07 -3.72E-07 -4.10E-07 -4.14E-07 -3.97E-07 -4.00E-07 -3.98E-07 -4.00E-07 -3.89E-07 -3.93E-07 -3.87E-07 -3.93E-07 -3.83E-07 -3.90E-07 -3.77E-07 -3.84E-07 -3.76E-07 -3.81E-07 -3.76E-07 -3.84E-07 -3.78E-07 -3.78E-07 -3.74E-07 -3.75E-07 50 -3.87E-07 -4.28E-07 -4.14E-07 -4.14E-07 -4.09E-07 -4.11E-07 -4.08E-07 -4.06E-07 -3.99E-07 -4.05E-07 -3.77E-07 -3.74E-07 24 Hr Anneal 60 -3.88E-07 -4.28E-07 -4.14E-07 -4.15E-07 -4.07E-07 -4.08E-07 -4.06E-07 -4.04E-07 -3.97E-07 -4.03E-07 -3.81E-07 -3.77E-07 168 Hr Anneal 70 -3.71E-07 -4.11E-07 -3.98E-07 -3.96E-07 -3.90E-07 -3.95E-07 -3.91E-07 -3.87E-07 -3.84E-07 -3.86E-07 -3.80E-07 -3.78E-07 -3.72E-07 -3.83E-07 -3.92E-07 -3.96E-07 -4.10E-07 -4.11E-07 -3.93E-07 1.55E-08 1.63E-08 1.66E-08 1.56E-08 1.49E-08 1.49E-08 1.47E-08 -3.30E-07 -3.39E-07 -3.46E-07 -3.53E-07 -3.70E-07 -3.70E-07 -3.53E-07 -4.14E-07 -4.28E-07 -4.37E-07 -4.39E-07 -4.51E-07 -4.51E-07 -4.34E-07 -3.69E-07 4.17E-09 -3.58E-07 -3.81E-07 -6.50E-07 PASS 6.50E-07 PASS -3.73E-07 4.30E-09 -3.61E-07 -3.85E-07 -7.00E-07 PASS 7.00E-07 PASS -3.80E-07 4.90E-09 -3.66E-07 -3.93E-07 -7.50E-07 PASS 7.50E-07 PASS -3.86E-07 5.00E-09 -3.73E-07 -4.00E-07 -7.50E-07 PASS 7.50E-07 PASS -4.05E-07 4.40E-09 -3.93E-07 -4.18E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 248 -4.04E-07 4.30E-09 -3.92E-07 -4.15E-07 -8.00E-07 PASS 8.00E-07 PASS -3.89E-07 4.51E-09 -3.76E-07 -4.01E-07 -8.00E-07 PASS 8.00E-07 PASS -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.119. Plot of -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 249 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.119. Raw data for -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.47E-07 -3.88E-07 -3.79E-07 -3.78E-07 -3.61E-07 -3.80E-07 -3.71E-07 -3.65E-07 -3.64E-07 -3.66E-07 -3.80E-07 -3.81E-07 10 -3.56E-07 -4.01E-07 -3.95E-07 -3.92E-07 -3.72E-07 -3.83E-07 -3.73E-07 -3.70E-07 -3.67E-07 -3.68E-07 -3.77E-07 -3.80E-07 Total Dose (krad(Si)) 20 30 -3.62E-07 -3.68E-07 -4.07E-07 -4.11E-07 -4.01E-07 -4.05E-07 -4.00E-07 -4.04E-07 -3.82E-07 -3.85E-07 -3.89E-07 -3.97E-07 -3.81E-07 -3.88E-07 -3.74E-07 -3.82E-07 -3.73E-07 -3.79E-07 -3.75E-07 -3.80E-07 -3.77E-07 -3.77E-07 -3.76E-07 -3.77E-07 50 -3.83E-07 -4.25E-07 -4.19E-07 -4.18E-07 -4.00E-07 -4.14E-07 -4.03E-07 -3.99E-07 -3.96E-07 -4.00E-07 -3.79E-07 -3.76E-07 24 Hr Anneal 60 -3.82E-07 -4.25E-07 -4.20E-07 -4.19E-07 -3.98E-07 -4.12E-07 -4.03E-07 -3.98E-07 -3.94E-07 -3.98E-07 -3.80E-07 -3.80E-07 168 Hr Anneal 70 -3.68E-07 -4.07E-07 -4.03E-07 -4.00E-07 -3.83E-07 -3.99E-07 -3.89E-07 -3.84E-07 -3.80E-07 -3.85E-07 -3.80E-07 -3.81E-07 -3.70E-07 -3.83E-07 -3.90E-07 -3.95E-07 -4.09E-07 -4.09E-07 -3.92E-07 1.63E-08 1.88E-08 1.84E-08 1.79E-08 1.74E-08 1.82E-08 1.63E-08 -3.26E-07 -3.31E-07 -3.40E-07 -3.46E-07 -3.61E-07 -3.59E-07 -3.48E-07 -4.15E-07 -4.35E-07 -4.41E-07 -4.44E-07 -4.57E-07 -4.59E-07 -4.37E-07 -3.69E-07 6.64E-09 -3.51E-07 -3.88E-07 -6.50E-07 PASS 6.50E-07 PASS -3.72E-07 6.32E-09 -3.55E-07 -3.89E-07 -7.00E-07 PASS 7.00E-07 PASS -3.78E-07 6.49E-09 -3.61E-07 -3.96E-07 -7.50E-07 PASS 7.50E-07 PASS -3.85E-07 7.41E-09 -3.65E-07 -4.06E-07 -7.50E-07 PASS 7.50E-07 PASS -4.02E-07 6.93E-09 -3.83E-07 -4.21E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 250 -4.01E-07 6.71E-09 -3.83E-07 -4.19E-07 -8.00E-07 PASS 8.00E-07 PASS -3.87E-07 7.36E-09 -3.67E-07 -4.08E-07 -8.00E-07 PASS 8.00E-07 PASS -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.120. Plot of -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 251 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.120. Raw data for -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.55E-07 -3.69E-07 -3.81E-07 -3.92E-07 -3.75E-07 -3.81E-07 -3.74E-07 -3.71E-07 -3.84E-07 -3.74E-07 -3.50E-07 -3.59E-07 10 -3.64E-07 -3.81E-07 -3.95E-07 -4.04E-07 -3.88E-07 -3.84E-07 -3.76E-07 -3.75E-07 -3.88E-07 -3.78E-07 -3.48E-07 -3.59E-07 Total Dose (krad(Si)) 20 30 -3.71E-07 -3.76E-07 -3.89E-07 -3.95E-07 -4.02E-07 -4.06E-07 -4.12E-07 -4.15E-07 -3.98E-07 -4.02E-07 -3.90E-07 -3.96E-07 -3.84E-07 -3.92E-07 -3.80E-07 -3.88E-07 -3.93E-07 -3.99E-07 -3.82E-07 -3.90E-07 -3.47E-07 -3.48E-07 -3.55E-07 -3.58E-07 50 -3.93E-07 -4.08E-07 -4.18E-07 -4.30E-07 -4.16E-07 -4.13E-07 -4.12E-07 -4.09E-07 -4.16E-07 -4.08E-07 -3.50E-07 -3.56E-07 24 Hr Anneal 60 -3.93E-07 -4.08E-07 -4.21E-07 -4.31E-07 -4.16E-07 -4.10E-07 -4.07E-07 -4.08E-07 -4.15E-07 -4.08E-07 -3.51E-07 -3.58E-07 168 Hr Anneal 70 -3.76E-07 -3.89E-07 -4.02E-07 -4.14E-07 -3.98E-07 -3.97E-07 -3.92E-07 -3.91E-07 -4.00E-07 -3.92E-07 -3.50E-07 -3.61E-07 -3.74E-07 -3.87E-07 -3.94E-07 -3.99E-07 -4.13E-07 -4.14E-07 -3.96E-07 1.36E-08 1.51E-08 1.57E-08 1.45E-08 1.38E-08 1.43E-08 1.42E-08 -3.37E-07 -3.45E-07 -3.51E-07 -3.59E-07 -3.75E-07 -3.74E-07 -3.57E-07 -4.11E-07 -4.28E-07 -4.37E-07 -4.39E-07 -4.51E-07 -4.53E-07 -4.35E-07 -3.77E-07 5.37E-09 -3.62E-07 -3.91E-07 -6.50E-07 PASS 6.50E-07 PASS -3.80E-07 5.55E-09 -3.65E-07 -3.95E-07 -7.00E-07 PASS 7.00E-07 PASS -3.86E-07 5.62E-09 -3.70E-07 -4.01E-07 -7.50E-07 PASS 7.50E-07 PASS -3.93E-07 4.56E-09 -3.80E-07 -4.06E-07 -7.50E-07 PASS 7.50E-07 PASS -4.11E-07 3.43E-09 -4.02E-07 -4.21E-07 -8.00E-07 PASS 8.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 252 -4.09E-07 3.08E-09 -4.01E-07 -4.18E-07 -8.00E-07 PASS 8.00E-07 PASS -3.94E-07 3.95E-09 -3.84E-07 -4.05E-07 -8.00E-07 PASS 8.00E-07 PASS Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.121. Plot of Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 253 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.121. Raw data for Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 10 7.15E-05 6.07E-05 3.80E-05 3.27E-05 2.51E-04 2.42E-04 4.70E-05 3.51E-05 1.84E-04 1.78E-04 2.16E-04 2.07E-04 -9.73E-05 -1.01E-04 4.61E-04 4.53E-04 -1.30E-05 -1.79E-05 7.93E-05 7.29E-05 -1.49E-04 -1.47E-04 2.61E-04 2.62E-04 24 Hr 168 Hr Total Dose (krad(Si)) Anneal Anneal 60 70 20 30 50 5.76E-05 5.22E-05 4.15E-05 4.61E-05 4.79E-05 2.90E-05 2.73E-05 2.34E-05 2.57E-05 1.91E-05 2.42E-04 2.43E-04 2.39E-04 2.38E-04 2.38E-04 3.05E-05 3.06E-05 3.11E-05 3.19E-05 2.88E-05 1.77E-04 1.79E-04 1.76E-04 1.77E-04 1.73E-04 2.06E-04 2.06E-04 2.02E-04 2.03E-04 1.95E-04 -9.86E-05 -9.79E-05 -9.76E-05 -9.60E-05 -9.63E-05 4.53E-04 4.54E-04 4.52E-04 4.50E-04 4.41E-04 -1.64E-05 -1.69E-05 -1.69E-05 -1.66E-05 -2.24E-05 7.55E-05 7.42E-05 7.06E-05 7.18E-05 7.38E-05 -1.45E-04 -1.45E-04 -1.44E-04 -1.46E-04 -1.44E-04 2.67E-04 2.65E-04 2.63E-04 2.61E-04 2.64E-04 1.18E-04 1.10E-04 1.07E-04 1.06E-04 1.02E-04 1.04E-04 1.01E-04 9.43E-05 9.50E-05 9.67E-05 9.85E-05 9.87E-05 9.73E-05 9.83E-05 3.77E-04 3.70E-04 3.72E-04 3.76E-04 3.73E-04 3.70E-04 3.71E-04 -1.40E-04 -1.51E-04 -1.58E-04 -1.64E-04 -1.69E-04 -1.63E-04 -1.68E-04 1.29E-04 2.19E-04 7.30E-04 -4.71E-04 -8.00E-04 PASS 8.00E-04 PASS 1.23E-04 2.17E-04 7.18E-04 -4.73E-04 -9.50E-04 PASS 9.50E-04 PASS 1.24E-04 2.16E-04 7.16E-04 -4.68E-04 -9.50E-04 PASS 9.50E-04 PASS 1.24E-04 2.16E-04 7.17E-04 -4.69E-04 -9.50E-04 PASS 9.50E-04 PASS 1.22E-04 2.15E-04 7.12E-04 -4.68E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 254 1.22E-04 2.14E-04 7.10E-04 -4.65E-04 -9.50E-04 PASS 9.50E-04 PASS 1.18E-04 2.11E-04 6.97E-04 -4.60E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.122. Plot of Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 255 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.122. Raw data for Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 10 1.27E-04 1.17E-04 -8.36E-05 -8.95E-05 1.54E-04 1.47E-04 1.20E-04 1.13E-04 3.64E-04 3.59E-04 -2.36E-06 -8.76E-06 1.52E-04 1.49E-04 2.54E-04 2.41E-04 1.92E-04 1.88E-04 -4.63E-05 -4.99E-05 1.10E-04 1.11E-04 3.90E-04 3.91E-04 24 Hr 168 Hr Total Dose (krad(Si)) Anneal Anneal 60 70 20 30 50 1.15E-04 1.14E-04 1.11E-04 1.13E-04 1.11E-04 -8.98E-05 -9.41E-05 -9.39E-05 -8.90E-05 -9.19E-05 1.47E-04 1.48E-04 1.43E-04 1.48E-04 1.46E-04 1.11E-04 1.14E-04 1.09E-04 1.11E-04 1.17E-04 3.55E-04 3.55E-04 3.52E-04 3.55E-04 3.47E-04 -8.16E-06 -5.99E-06 -2.84E-06 -1.75E-06 -5.98E-06 1.48E-04 1.49E-04 1.51E-04 1.55E-04 1.42E-04 2.40E-04 2.38E-04 2.34E-04 2.37E-04 2.30E-04 1.92E-04 1.91E-04 1.95E-04 1.95E-04 1.88E-04 -4.69E-05 -4.79E-05 -4.93E-05 -4.33E-05 -4.55E-05 1.11E-04 1.14E-04 1.13E-04 1.15E-04 1.16E-04 3.93E-04 3.91E-04 3.95E-04 3.88E-04 3.93E-04 1.36E-04 1.29E-04 1.28E-04 1.27E-04 1.24E-04 1.27E-04 1.26E-04 1.59E-04 1.59E-04 1.58E-04 1.59E-04 1.58E-04 1.58E-04 1.56E-04 5.72E-04 5.65E-04 5.61E-04 5.64E-04 5.58E-04 5.59E-04 5.52E-04 -2.99E-04 -3.07E-04 -3.05E-04 -3.10E-04 -3.10E-04 -3.05E-04 -3.01E-04 1.10E-04 1.29E-04 4.62E-04 -2.43E-04 -8.00E-04 PASS 8.00E-04 PASS 1.04E-04 1.27E-04 4.52E-04 -2.44E-04 -9.50E-04 PASS 9.50E-04 PASS 1.05E-04 1.26E-04 4.51E-04 -2.41E-04 -9.50E-04 PASS 9.50E-04 PASS 1.05E-04 1.25E-04 4.48E-04 -2.38E-04 -9.50E-04 PASS 9.50E-04 PASS 1.06E-04 1.25E-04 4.48E-04 -2.37E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 256 1.08E-04 1.24E-04 4.48E-04 -2.31E-04 -9.50E-04 PASS 9.50E-04 PASS 1.02E-04 1.21E-04 4.34E-04 -2.31E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.123. Plot of Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 257 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.123. Raw data for Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 10 5.97E-04 5.87E-04 1.41E-04 1.34E-04 2.77E-04 2.72E-04 2.61E-04 2.55E-04 3.02E-05 2.54E-05 1.58E-04 1.52E-04 2.23E-04 2.16E-04 2.49E-04 2.45E-04 2.60E-04 2.57E-04 -3.79E-05 -4.06E-05 4.16E-04 4.20E-04 1.93E-04 1.99E-04 24 Hr 168 Hr Total Dose (krad(Si)) Anneal Anneal 60 70 20 30 50 5.83E-04 5.77E-04 5.73E-04 5.72E-04 5.69E-04 1.33E-04 1.27E-04 1.29E-04 1.33E-04 1.32E-04 2.66E-04 2.65E-04 2.61E-04 2.58E-04 2.49E-04 2.49E-04 2.43E-04 2.40E-04 2.39E-04 2.35E-04 2.12E-05 1.68E-05 1.64E-05 1.36E-05 1.45E-05 1.51E-04 1.51E-04 1.47E-04 1.47E-04 1.36E-04 2.18E-04 2.15E-04 2.10E-04 2.13E-04 2.17E-04 2.41E-04 2.39E-04 2.34E-04 2.36E-04 2.24E-04 2.57E-04 2.57E-04 2.52E-04 2.55E-04 2.58E-04 -4.18E-05 -4.34E-05 -4.50E-05 -4.16E-05 -3.86E-05 4.21E-04 4.22E-04 4.24E-04 4.22E-04 4.24E-04 1.95E-04 1.94E-04 1.99E-04 1.93E-04 1.96E-04 2.61E-04 2.55E-04 2.50E-04 2.46E-04 2.44E-04 2.43E-04 2.40E-04 2.13E-04 2.11E-04 2.10E-04 2.10E-04 2.08E-04 2.08E-04 2.07E-04 8.45E-04 8.33E-04 8.27E-04 8.23E-04 8.15E-04 8.14E-04 8.06E-04 -3.22E-04 -3.23E-04 -3.26E-04 -3.31E-04 -3.27E-04 -3.28E-04 -3.27E-04 1.70E-04 1.23E-04 5.08E-04 -1.67E-04 -8.00E-04 PASS 8.00E-04 PASS 1.66E-04 1.22E-04 5.01E-04 -1.69E-04 -9.50E-04 PASS 9.50E-04 PASS 1.65E-04 1.22E-04 5.01E-04 -1.71E-04 -9.50E-04 PASS 9.50E-04 PASS 1.64E-04 1.22E-04 4.99E-04 -1.72E-04 -9.50E-04 PASS 9.50E-04 PASS 1.60E-04 1.21E-04 4.92E-04 -1.72E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 258 1.62E-04 1.21E-04 4.93E-04 -1.69E-04 -9.50E-04 PASS 9.50E-04 PASS 1.59E-04 1.19E-04 4.86E-04 -1.68E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.124. Plot of Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 259 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.124. Raw data for Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 10 -1.77E-04 -1.86E-04 1.19E-04 1.10E-04 1.49E-04 1.41E-04 1.37E-04 1.30E-04 -1.61E-04 -1.69E-04 1.35E-04 1.26E-04 2.94E-04 2.87E-04 1.04E-04 9.72E-05 1.83E-04 1.76E-04 3.34E-05 2.69E-05 4.24E-04 4.27E-04 3.74E-05 4.41E-05 24 Hr 168 Hr Total Dose (krad(Si)) Anneal Anneal 60 70 20 30 50 -1.89E-04 -1.90E-04 -1.94E-04 -1.92E-04 -1.85E-04 1.09E-04 1.08E-04 1.05E-04 1.06E-04 1.10E-04 1.42E-04 1.40E-04 1.34E-04 1.35E-04 1.24E-04 1.30E-04 1.30E-04 1.29E-04 1.31E-04 1.25E-04 -1.70E-04 -1.74E-04 -1.69E-04 -1.68E-04 -1.80E-04 1.29E-04 1.31E-04 1.40E-04 1.37E-04 1.37E-04 2.91E-04 2.91E-04 2.91E-04 2.91E-04 2.81E-04 9.64E-05 9.92E-05 1.01E-04 1.01E-04 1.01E-04 1.79E-04 1.81E-04 1.85E-04 1.82E-04 1.79E-04 2.78E-05 2.96E-05 3.16E-05 3.30E-05 3.05E-05 4.27E-04 4.30E-04 4.27E-04 4.25E-04 4.28E-04 4.48E-05 4.48E-05 4.58E-05 4.35E-05 4.46E-05 1.35E-05 5.29E-06 4.37E-06 2.80E-06 1.05E-06 2.21E-06 -1.18E-06 1.67E-04 1.67E-04 1.68E-04 1.69E-04 1.67E-04 1.67E-04 1.66E-04 4.71E-04 4.63E-04 4.66E-04 4.67E-04 4.59E-04 4.60E-04 4.53E-04 -4.44E-04 -4.53E-04 -4.57E-04 -4.61E-04 -4.57E-04 -4.55E-04 -4.55E-04 1.50E-04 9.74E-05 4.17E-04 -1.17E-04 -8.00E-04 PASS 8.00E-04 PASS 1.43E-04 9.72E-05 4.09E-04 -1.24E-04 -9.50E-04 PASS 9.50E-04 PASS 1.45E-04 9.84E-05 4.14E-04 -1.25E-04 -9.50E-04 PASS 9.50E-04 PASS 1.46E-04 9.78E-05 4.14E-04 -1.22E-04 -9.50E-04 PASS 9.50E-04 PASS 1.50E-04 9.69E-05 4.15E-04 -1.16E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 260 1.49E-04 9.63E-05 4.13E-04 -1.15E-04 -9.50E-04 PASS 9.50E-04 PASS 1.46E-04 9.32E-05 4.01E-04 -1.10E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.125. Plot of Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 261 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.125. Raw data for Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -9.15E-09 -3.30E-10 -2.76E-09 -1.57E-09 1.16E-08 -3.70E-10 1.11E-08 -4.60E-10 -1.05E-09 1.09E-08 9.00E-11 1.37E-09 10 -1.07E-08 -2.45E-09 -4.75E-09 -4.30E-09 8.75E-09 6.10E-10 1.30E-08 1.80E-09 -2.80E-10 1.18E-08 3.15E-09 6.51E-09 Total Dose (krad(Si)) 20 30 -1.35E-08 -1.54E-08 -4.59E-09 -7.14E-09 -7.30E-09 -6.96E-09 -6.31E-09 -7.34E-09 7.21E-09 7.16E-09 1.12E-09 1.30E-09 1.41E-08 1.45E-08 2.49E-09 3.40E-09 6.60E-10 2.10E-09 1.22E-08 1.30E-08 4.75E-09 5.69E-09 7.58E-09 7.77E-09 50 -2.15E-08 -9.79E-09 -8.90E-09 -1.00E-08 3.72E-09 1.30E-09 1.60E-08 4.37E-09 2.93E-09 1.44E-08 6.04E-09 7.36E-09 24 Hr Anneal 60 -1.88E-08 -8.09E-09 -7.30E-09 -7.51E-09 6.40E-09 3.45E-09 1.83E-08 5.26E-09 4.17E-09 1.51E-08 6.68E-09 7.40E-09 168 Hr Anneal 70 -1.85E-08 -8.88E-09 -8.93E-09 -8.62E-09 5.00E-09 6.70E-10 1.37E-08 3.46E-09 8.90E-10 1.33E-08 7.76E-09 8.15E-09 -4.52E-10 -2.70E-09 -4.90E-09 -5.94E-09 -9.30E-09 -7.05E-09 -7.98E-09 7.52E-09 7.11E-09 7.56E-09 8.16E-09 8.93E-09 8.94E-09 8.37E-09 2.02E-08 1.68E-08 1.58E-08 1.64E-08 1.52E-08 1.75E-08 1.50E-08 -2.11E-08 -2.22E-08 -2.56E-08 -2.83E-08 -3.38E-08 -3.16E-08 -3.09E-08 4.03E-09 6.38E-09 2.15E-08 -1.35E-08 -6.50E-08 PASS 6.50E-08 PASS 5.38E-09 6.45E-09 2.31E-08 -1.23E-08 -6.50E-08 PASS 6.50E-08 PASS 6.11E-09 6.49E-09 2.39E-08 -1.17E-08 -6.50E-08 PASS 6.50E-08 PASS 6.85E-09 6.34E-09 2.42E-08 -1.05E-08 -6.50E-08 PASS 6.50E-08 PASS 7.80E-09 6.86E-09 2.66E-08 -1.10E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 262 9.25E-09 6.91E-09 2.82E-08 -9.69E-09 -6.50E-08 PASS 6.50E-08 PASS 6.39E-09 6.56E-09 2.44E-08 -1.16E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.126. Plot of Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 263 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.126. Raw data for Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 10 5.69E-09 4.59E-09 1.67E-09 9.60E-10 3.29E-09 1.87E-09 1.22E-08 9.36E-09 2.99E-09 1.60E-10 -2.01E-09 -1.12E-09 5.86E-09 6.84E-09 2.48E-09 4.36E-09 5.63E-09 6.97E-09 1.62E-08 1.72E-08 2.75E-09 5.23E-09 1.40E-08 1.99E-08 Total Dose (krad(Si)) 20 30 2.79E-09 1.20E-09 -2.40E-10 -2.09E-09 2.40E-10 -4.80E-10 7.33E-09 6.98E-09 -2.55E-09 -3.36E-09 -7.20E-10 -9.20E-10 7.12E-09 8.05E-09 4.76E-09 5.23E-09 8.64E-09 9.07E-09 1.84E-08 1.81E-08 6.57E-09 7.52E-09 2.01E-08 2.01E-08 50 -1.26E-09 -3.88E-09 -2.45E-09 5.17E-09 -5.70E-09 1.10E-10 6.90E-09 4.67E-09 9.85E-09 1.82E-08 7.86E-09 2.02E-08 24 Hr Anneal 60 -2.50E-10 -2.08E-09 -7.60E-10 7.12E-09 -2.63E-09 1.74E-09 8.66E-09 7.05E-09 1.17E-08 1.99E-08 8.53E-09 2.06E-08 168 Hr Anneal 70 -6.90E-10 -4.04E-09 -1.75E-09 4.72E-09 -4.74E-09 -7.80E-10 7.01E-09 2.53E-09 8.23E-09 1.79E-08 9.68E-09 2.10E-08 5.16E-09 3.39E-09 1.51E-09 4.50E-10 -1.62E-09 2.80E-10 -1.30E-09 4.17E-09 3.73E-09 3.76E-09 4.03E-09 4.14E-09 3.94E-09 3.75E-09 1.66E-08 1.36E-08 1.18E-08 1.15E-08 9.74E-09 1.11E-08 8.97E-09 -6.28E-09 -6.85E-09 -8.81E-09 -1.06E-08 -1.30E-08 -1.05E-08 -1.16E-08 5.64E-09 6.72E-09 2.41E-08 -1.28E-08 -6.50E-08 PASS 6.50E-08 PASS 6.86E-09 6.66E-09 2.51E-08 -1.14E-08 -6.50E-08 PASS 6.50E-08 PASS 7.63E-09 6.97E-09 2.67E-08 -1.15E-08 -6.50E-08 PASS 6.50E-08 PASS 7.91E-09 6.91E-09 2.68E-08 -1.10E-08 -6.50E-08 PASS 6.50E-08 PASS 7.95E-09 6.75E-09 2.64E-08 -1.05E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 264 9.80E-09 6.70E-09 2.82E-08 -8.56E-09 -6.50E-08 PASS 6.50E-08 PASS 6.98E-09 7.08E-09 2.64E-08 -1.24E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.127. Plot of Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 265 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.127. Raw data for Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 5.43E-09 1.70E-10 -2.68E-09 -1.06E-09 8.07E-09 2.26E-09 4.30E-10 -1.33E-08 -2.80E-10 -6.72E-09 1.04E-08 4.70E-10 10 8.56E-09 2.10E-09 -1.96E-09 -1.11E-09 7.67E-09 6.43E-09 4.14E-09 -8.16E-09 3.49E-09 -2.75E-09 1.62E-08 1.02E-08 Total Dose (krad(Si)) 20 30 5.69E-09 3.87E-09 1.72E-09 4.70E-10 -3.67E-09 -3.38E-09 -2.53E-09 -3.33E-09 5.45E-09 4.17E-09 7.88E-09 8.56E-09 5.37E-09 6.11E-09 -7.39E-09 -5.97E-09 4.23E-09 4.94E-09 -1.90E-09 -1.88E-09 1.77E-08 1.89E-08 1.09E-08 1.11E-08 50 1.46E-09 -7.10E-10 -5.97E-09 -5.69E-09 9.70E-10 8.72E-09 5.07E-09 -6.50E-09 5.01E-09 -2.80E-09 1.92E-08 1.06E-08 24 Hr Anneal 60 3.19E-09 1.03E-09 -3.53E-09 -3.69E-09 3.76E-09 1.04E-08 6.59E-09 -4.57E-09 6.23E-09 -8.10E-10 2.01E-08 1.10E-08 168 Hr Anneal 70 1.58E-09 -2.40E-09 -2.04E-09 -5.25E-09 2.81E-09 8.02E-09 5.12E-09 -8.82E-09 3.63E-09 -1.99E-09 2.10E-08 1.14E-08 1.99E-09 3.05E-09 1.33E-09 3.60E-10 -1.99E-09 1.52E-10 -1.06E-09 4.56E-09 4.87E-09 4.36E-09 3.69E-09 3.60E-09 3.58E-09 3.25E-09 1.45E-08 1.64E-08 1.33E-08 1.05E-08 7.88E-09 9.98E-09 7.85E-09 -1.05E-08 -1.03E-08 -1.06E-08 -9.76E-09 -1.19E-08 -9.67E-09 -9.97E-09 -3.52E-09 6.42E-09 1.41E-08 -2.11E-08 -6.50E-08 PASS 6.50E-08 PASS 6.30E-10 5.98E-09 1.70E-08 -1.58E-08 -6.50E-08 PASS 6.50E-08 PASS 1.64E-09 6.20E-09 1.86E-08 -1.54E-08 -6.50E-08 PASS 6.50E-08 PASS 2.35E-09 6.05E-09 1.89E-08 -1.42E-08 -6.50E-08 PASS 6.50E-08 PASS 1.90E-09 6.30E-09 1.92E-08 -1.54E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 266 3.57E-09 6.09E-09 2.03E-08 -1.31E-08 -6.50E-08 PASS 6.50E-08 PASS 1.19E-09 6.68E-09 1.95E-08 -1.71E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.128. Plot of Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 267 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.128. Raw data for Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -4.60E-09 -6.21E-09 -3.07E-09 -2.15E-09 -7.48E-09 3.20E-09 -1.11E-08 1.27E-08 -4.92E-09 -1.10E-10 -3.16E-09 -9.97E-09 10 -1.98E-09 -4.65E-09 -2.33E-09 -1.45E-09 -8.13E-09 7.33E-09 -6.24E-09 1.89E-08 0.00E+00 4.69E-09 3.14E-09 9.00E-10 Total Dose (krad(Si)) 20 30 -3.14E-09 -4.19E-09 -5.14E-09 -6.69E-09 -3.67E-09 -4.56E-09 -2.98E-09 -3.60E-09 -9.67E-09 -9.73E-09 1.02E-08 1.10E-08 -4.33E-09 -2.88E-09 2.11E-08 2.23E-08 1.37E-09 2.04E-09 5.48E-09 6.23E-09 5.80E-09 7.34E-09 3.10E-09 3.37E-09 50 -8.36E-09 -8.88E-09 -6.63E-09 -4.77E-09 -1.19E-08 1.27E-08 -1.57E-09 2.50E-08 3.41E-09 7.03E-09 8.00E-09 3.95E-09 24 Hr Anneal 60 -6.05E-09 -7.05E-09 -4.58E-09 -2.02E-09 -9.93E-09 1.38E-08 3.30E-10 2.74E-08 4.69E-09 9.09E-09 8.49E-09 3.90E-09 168 Hr Anneal 70 -7.08E-09 -6.92E-09 -5.67E-09 -3.31E-09 -1.13E-08 1.05E-08 -3.15E-09 2.27E-08 2.01E-09 6.55E-09 9.80E-09 4.22E-09 -4.70E-09 -3.71E-09 -4.92E-09 -5.75E-09 -8.11E-09 -5.93E-09 -6.85E-09 2.19E-09 2.76E-09 2.79E-09 2.51E-09 2.67E-09 2.93E-09 2.90E-09 1.30E-09 3.85E-09 2.73E-09 1.13E-09 -7.91E-10 2.11E-09 1.10E-09 -1.07E-08 -1.13E-08 -1.26E-08 -1.26E-08 -1.54E-08 -1.40E-08 -1.48E-08 -4.00E-11 8.95E-09 2.45E-08 -2.46E-08 -6.50E-08 PASS 6.50E-08 PASS 4.94E-09 9.36E-09 3.06E-08 -2.07E-08 -6.50E-08 PASS 6.50E-08 PASS 6.75E-09 9.61E-09 3.31E-08 -1.96E-08 -6.50E-08 PASS 6.50E-08 PASS 7.74E-09 9.63E-09 3.41E-08 -1.87E-08 -6.50E-08 PASS 6.50E-08 PASS 9.31E-09 1.02E-08 3.72E-08 -1.86E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 268 1.11E-08 1.04E-08 3.96E-08 -1.75E-08 -6.50E-08 PASS 6.50E-08 PASS 7.73E-09 9.82E-09 3.46E-08 -1.92E-08 -6.50E-08 PASS 6.50E-08 PASS +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.129. Plot of +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 269 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.129. Raw data for +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V Device 0 10 557 3.50E-07 3.61E-07 563 3.49E-07 3.71E-07 564 3.58E-07 3.86E-07 567 3.49E-07 3.75E-07 569 3.62E-07 3.92E-07 570 3.47E-07 3.55E-07 571 3.55E-07 3.65E-07 572 3.57E-07 3.68E-07 573 3.42E-07 3.47E-07 574 3.53E-07 3.58E-07 584 3.37E-07 3.42E-07 585 3.56E-07 3.64E-07 Biased Statistics Average Biased 3.54E-07 3.77E-07 Std Dev Biased 6.18E-09 1.20E-08 Ps90%/90% (+KTL) Biased 3.70E-07 4.10E-07 Ps90%/90% (-KTL) Biased 3.37E-07 3.44E-07 Un-Biased Statistics Average Un-Biased 3.51E-07 3.58E-07 Std Dev Un-Biased 5.89E-09 8.34E-09 Ps90%/90% (+KTL) Un-Biased 3.67E-07 3.81E-07 Ps90%/90% (-KTL) Un-Biased 3.35E-07 3.36E-07 Specification MIN -6.50E-07 -7.00E-07 Status PASS PASS Specification MAX 6.50E-07 7.00E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.83E-07 3.98E-07 3.92E-07 4.04E-07 4.06E-07 4.20E-07 3.95E-07 4.07E-07 4.12E-07 4.26E-07 3.71E-07 3.89E-07 3.80E-07 4.01E-07 3.86E-07 4.06E-07 3.65E-07 3.85E-07 3.74E-07 3.95E-07 3.43E-07 3.43E-07 3.61E-07 3.66E-07 3.97E-07 1.16E-08 4.29E-07 3.66E-07 4.11E-07 1.16E-08 4.43E-07 3.79E-07 168 Hr Anneal 70 4.00E-07 4.00E-07 4.13E-07 4.01E-07 4.20E-07 3.95E-07 4.09E-07 4.17E-07 3.94E-07 4.04E-07 3.46E-07 3.66E-07 4.39E-07 1.04E-08 4.67E-07 4.10E-07 4.38E-07 1.14E-08 4.70E-07 4.07E-07 4.07E-07 9.51E-09 4.33E-07 3.81E-07 3.75E-07 3.95E-07 4.32E-07 4.32E-07 4.04E-07 8.20E-09 8.48E-09 8.79E-09 9.46E-09 9.38E-09 3.98E-07 4.18E-07 4.56E-07 4.58E-07 4.29E-07 3.53E-07 3.72E-07 4.08E-07 4.06E-07 3.78E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07 PASS PASS PASS PASS PASS 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 270 50 4.28E-07 4.34E-07 4.46E-07 4.32E-07 4.54E-07 4.25E-07 4.37E-07 4.44E-07 4.22E-07 4.33E-07 3.44E-07 3.70E-07 24 Hr Anneal 60 4.28E-07 4.31E-07 4.46E-07 4.33E-07 4.55E-07 4.25E-07 4.38E-07 4.44E-07 4.21E-07 4.32E-07 3.45E-07 3.70E-07 +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.130. Plot of +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 271 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.130. Raw data for +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V Device 0 10 557 3.46E-07 3.57E-07 563 3.54E-07 3.76E-07 564 3.58E-07 3.85E-07 567 3.53E-07 3.78E-07 569 3.47E-07 3.76E-07 570 3.46E-07 3.55E-07 571 3.43E-07 3.54E-07 572 3.45E-07 3.50E-07 573 3.37E-07 3.41E-07 574 3.62E-07 3.68E-07 584 3.51E-07 3.58E-07 585 3.62E-07 3.70E-07 Biased Statistics Average Biased 3.51E-07 3.74E-07 Std Dev Biased 4.92E-09 1.03E-08 Ps90%/90% (+KTL) Biased 3.65E-07 4.03E-07 Ps90%/90% (-KTL) Biased 3.38E-07 3.46E-07 Un-Biased Statistics Average Un-Biased 3.47E-07 3.54E-07 Std Dev Un-Biased 9.07E-09 9.65E-09 Ps90%/90% (+KTL) Un-Biased 3.72E-07 3.80E-07 Ps90%/90% (-KTL) Un-Biased 3.22E-07 3.27E-07 Specification MIN -6.50E-07 -7.00E-07 Status PASS PASS Specification MAX 6.50E-07 7.00E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.80E-07 3.99E-07 3.96E-07 4.07E-07 4.06E-07 4.16E-07 3.96E-07 4.09E-07 3.98E-07 4.11E-07 3.71E-07 3.92E-07 3.69E-07 3.89E-07 3.69E-07 3.87E-07 3.58E-07 3.78E-07 3.84E-07 4.06E-07 3.62E-07 3.59E-07 3.68E-07 3.71E-07 3.95E-07 9.25E-09 4.20E-07 3.70E-07 4.09E-07 6.15E-09 4.25E-07 3.92E-07 168 Hr Anneal 70 3.97E-07 4.04E-07 4.13E-07 4.04E-07 4.04E-07 4.00E-07 3.96E-07 3.98E-07 3.87E-07 4.16E-07 3.62E-07 3.72E-07 4.36E-07 5.25E-09 4.50E-07 4.21E-07 4.37E-07 6.37E-09 4.55E-07 4.20E-07 4.05E-07 5.73E-09 4.20E-07 3.89E-07 3.70E-07 3.90E-07 4.27E-07 4.27E-07 3.99E-07 9.34E-09 1.00E-08 1.22E-08 1.05E-08 1.07E-08 3.96E-07 4.18E-07 4.60E-07 4.55E-07 4.29E-07 3.45E-07 3.63E-07 3.93E-07 3.98E-07 3.70E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07 PASS PASS PASS PASS PASS 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 272 50 4.31E-07 4.35E-07 4.45E-07 4.34E-07 4.35E-07 4.27E-07 4.23E-07 4.25E-07 4.13E-07 4.46E-07 3.61E-07 3.74E-07 24 Hr Anneal 60 4.30E-07 4.36E-07 4.48E-07 4.35E-07 4.37E-07 4.28E-07 4.24E-07 4.25E-07 4.14E-07 4.43E-07 3.64E-07 3.76E-07 +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.131. Plot of +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 273 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.131. Raw data for +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V Device 0 10 557 3.54E-07 3.69E-07 563 3.62E-07 3.86E-07 564 3.72E-07 4.01E-07 567 3.42E-07 3.65E-07 569 3.59E-07 3.88E-07 570 3.51E-07 3.59E-07 571 3.39E-07 3.50E-07 572 3.46E-07 3.58E-07 573 3.37E-07 3.37E-07 574 3.61E-07 3.69E-07 584 3.62E-07 3.68E-07 585 3.62E-07 3.72E-07 Biased Statistics Average Biased 3.58E-07 3.82E-07 Std Dev Biased 1.08E-08 1.47E-08 Ps90%/90% (+KTL) Biased 3.87E-07 4.22E-07 Ps90%/90% (-KTL) Biased 3.28E-07 3.42E-07 Un-Biased Statistics Average Un-Biased 3.47E-07 3.55E-07 Std Dev Un-Biased 9.66E-09 1.19E-08 Ps90%/90% (+KTL) Un-Biased 3.73E-07 3.87E-07 Ps90%/90% (-KTL) Un-Biased 3.20E-07 3.22E-07 Specification MIN -6.50E-07 -7.00E-07 Status PASS PASS Specification MAX 6.50E-07 7.00E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.90E-07 4.06E-07 4.03E-07 4.15E-07 4.21E-07 4.33E-07 3.86E-07 3.97E-07 4.07E-07 4.19E-07 3.76E-07 3.96E-07 3.64E-07 3.83E-07 3.75E-07 3.94E-07 3.53E-07 3.73E-07 3.85E-07 4.06E-07 3.68E-07 3.68E-07 3.68E-07 3.71E-07 4.01E-07 1.40E-08 4.40E-07 3.63E-07 4.14E-07 1.38E-08 4.52E-07 3.76E-07 168 Hr Anneal 70 4.07E-07 4.11E-07 4.27E-07 3.91E-07 4.15E-07 4.03E-07 3.89E-07 4.02E-07 3.81E-07 4.15E-07 3.69E-07 3.71E-07 4.42E-07 1.31E-08 4.78E-07 4.06E-07 4.42E-07 1.29E-08 4.78E-07 4.07E-07 4.10E-07 1.33E-08 4.47E-07 3.74E-07 3.71E-07 3.90E-07 4.26E-07 4.26E-07 3.98E-07 1.23E-08 1.27E-08 1.44E-08 1.44E-08 1.34E-08 4.04E-07 4.25E-07 4.65E-07 4.65E-07 4.35E-07 3.37E-07 3.56E-07 3.86E-07 3.86E-07 3.61E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07 PASS PASS PASS PASS PASS 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 274 50 4.39E-07 4.43E-07 4.60E-07 4.23E-07 4.43E-07 4.29E-07 4.18E-07 4.31E-07 4.06E-07 4.44E-07 3.69E-07 3.74E-07 24 Hr Anneal 60 4.38E-07 4.40E-07 4.60E-07 4.25E-07 4.48E-07 4.28E-07 4.19E-07 4.32E-07 4.06E-07 4.45E-07 3.70E-07 3.76E-07 +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.132. Plot of +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 275 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.132. Raw data for +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V Device 0 10 557 3.48E-07 3.60E-07 563 3.53E-07 3.76E-07 564 3.56E-07 3.83E-07 567 3.58E-07 3.84E-07 569 3.56E-07 3.83E-07 570 3.62E-07 3.68E-07 571 3.42E-07 3.52E-07 572 3.74E-07 3.85E-07 573 3.47E-07 3.52E-07 574 3.51E-07 3.57E-07 584 3.42E-07 3.47E-07 585 3.58E-07 3.64E-07 Biased Statistics Average Biased 3.54E-07 3.77E-07 Std Dev Biased 3.83E-09 1.02E-08 Ps90%/90% (+KTL) Biased 3.65E-07 4.05E-07 Ps90%/90% (-KTL) Biased 3.44E-07 3.49E-07 Un-Biased Statistics Average Un-Biased 3.55E-07 3.63E-07 Std Dev Un-Biased 1.28E-08 1.40E-08 Ps90%/90% (+KTL) Un-Biased 3.90E-07 4.01E-07 Ps90%/90% (-KTL) Un-Biased 3.20E-07 3.24E-07 Specification MIN -6.50E-07 -7.00E-07 Status PASS PASS Specification MAX 6.50E-07 7.00E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.81E-07 3.94E-07 3.95E-07 4.08E-07 4.01E-07 4.14E-07 4.03E-07 4.16E-07 4.03E-07 4.15E-07 3.86E-07 4.02E-07 3.69E-07 3.87E-07 4.03E-07 4.23E-07 3.70E-07 3.89E-07 3.71E-07 3.93E-07 3.47E-07 3.49E-07 3.64E-07 3.67E-07 3.96E-07 9.44E-09 4.22E-07 3.70E-07 4.10E-07 9.13E-09 4.35E-07 3.85E-07 168 Hr Anneal 70 3.96E-07 4.07E-07 4.09E-07 4.13E-07 4.10E-07 4.09E-07 3.97E-07 4.34E-07 3.98E-07 4.04E-07 3.52E-07 3.69E-07 4.38E-07 7.37E-09 4.58E-07 4.18E-07 4.38E-07 7.00E-09 4.58E-07 4.19E-07 4.07E-07 6.40E-09 4.24E-07 3.89E-07 3.80E-07 3.99E-07 4.37E-07 4.37E-07 4.09E-07 1.45E-08 1.46E-08 1.58E-08 1.53E-08 1.52E-08 4.20E-07 4.39E-07 4.80E-07 4.79E-07 4.50E-07 3.40E-07 3.59E-07 3.93E-07 3.95E-07 3.67E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07 PASS PASS PASS PASS PASS 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 276 50 4.26E-07 4.36E-07 4.41E-07 4.44E-07 4.43E-07 4.39E-07 4.25E-07 4.63E-07 4.25E-07 4.31E-07 3.49E-07 3.71E-07 24 Hr Anneal 60 4.27E-07 4.36E-07 4.42E-07 4.44E-07 4.43E-07 4.37E-07 4.29E-07 4.64E-07 4.26E-07 4.31E-07 3.52E-07 3.71E-07 -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.133. Plot of -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 277 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.133. Raw data for -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V Device 0 10 557 3.60E-07 3.74E-07 563 3.50E-07 3.76E-07 564 3.63E-07 3.92E-07 567 3.52E-07 3.78E-07 569 3.53E-07 3.84E-07 570 3.48E-07 3.54E-07 571 3.45E-07 3.53E-07 572 3.59E-07 3.67E-07 573 3.44E-07 3.48E-07 574 3.44E-07 3.48E-07 584 3.37E-07 3.40E-07 585 3.57E-07 3.59E-07 Biased Statistics Average Biased 3.55E-07 3.81E-07 Std Dev Biased 5.61E-09 7.30E-09 Ps90%/90% (+KTL) Biased 3.71E-07 4.01E-07 Ps90%/90% (-KTL) Biased 3.40E-07 3.61E-07 Un-Biased Statistics Average Un-Biased 3.48E-07 3.54E-07 Std Dev Un-Biased 6.42E-09 7.81E-09 Ps90%/90% (+KTL) Un-Biased 3.66E-07 3.75E-07 Ps90%/90% (-KTL) Un-Biased 3.31E-07 3.32E-07 Specification MIN -6.50E-07 -7.00E-07 Status PASS PASS Specification MAX 6.50E-07 7.00E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.97E-07 4.13E-07 3.97E-07 4.13E-07 4.16E-07 4.29E-07 4.01E-07 4.16E-07 4.07E-07 4.22E-07 3.71E-07 3.90E-07 3.68E-07 3.86E-07 3.84E-07 4.05E-07 3.64E-07 3.83E-07 3.64E-07 3.82E-07 3.39E-07 3.38E-07 3.57E-07 3.60E-07 4.04E-07 8.08E-09 4.26E-07 3.81E-07 4.19E-07 6.82E-09 4.37E-07 4.00E-07 168 Hr Anneal 70 4.20E-07 4.12E-07 4.24E-07 4.12E-07 4.17E-07 3.96E-07 3.97E-07 4.16E-07 3.94E-07 3.92E-07 3.37E-07 3.59E-07 4.49E-07 5.41E-09 4.64E-07 4.34E-07 4.47E-07 6.96E-09 4.66E-07 4.28E-07 4.17E-07 5.23E-09 4.31E-07 4.03E-07 3.70E-07 3.89E-07 4.26E-07 4.25E-07 3.99E-07 8.47E-09 9.12E-09 9.62E-09 9.41E-09 9.53E-09 3.93E-07 4.14E-07 4.52E-07 4.51E-07 4.25E-07 3.47E-07 3.64E-07 3.99E-07 3.99E-07 3.73E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07 PASS PASS PASS PASS PASS 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 278 50 4.52E-07 4.43E-07 4.56E-07 4.44E-07 4.50E-07 4.26E-07 4.22E-07 4.42E-07 4.19E-07 4.20E-07 3.39E-07 3.63E-07 24 Hr Anneal 60 4.49E-07 4.41E-07 4.57E-07 4.40E-07 4.48E-07 4.24E-07 4.22E-07 4.41E-07 4.19E-07 4.18E-07 3.39E-07 3.64E-07 -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.134. Plot of -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 279 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.134. Raw data for -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V Device 0 10 557 3.39E-07 3.57E-07 563 3.53E-07 3.76E-07 564 3.56E-07 3.85E-07 567 3.41E-07 3.69E-07 569 3.45E-07 3.75E-07 570 3.52E-07 3.56E-07 571 3.40E-07 3.49E-07 572 3.42E-07 3.48E-07 573 3.37E-07 3.35E-07 574 3.46E-07 3.51E-07 584 3.51E-07 3.54E-07 585 3.50E-07 3.52E-07 Biased Statistics Average Biased 3.47E-07 3.72E-07 Std Dev Biased 7.21E-09 1.04E-08 Ps90%/90% (+KTL) Biased 3.67E-07 4.01E-07 Ps90%/90% (-KTL) Biased 3.27E-07 3.44E-07 Un-Biased Statistics Average Un-Biased 3.43E-07 3.48E-07 Std Dev Un-Biased 5.76E-09 7.85E-09 Ps90%/90% (+KTL) Un-Biased 3.59E-07 3.69E-07 Ps90%/90% (-KTL) Un-Biased 3.27E-07 3.26E-07 Specification MIN -6.50E-07 -7.00E-07 Status PASS PASS Specification MAX 6.50E-07 7.00E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.79E-07 3.98E-07 3.96E-07 4.11E-07 4.08E-07 4.20E-07 3.91E-07 4.03E-07 4.00E-07 4.11E-07 3.74E-07 3.92E-07 3.65E-07 3.81E-07 3.66E-07 3.83E-07 3.51E-07 3.68E-07 3.68E-07 3.88E-07 3.55E-07 3.53E-07 3.50E-07 3.52E-07 3.95E-07 1.09E-08 4.25E-07 3.65E-07 4.09E-07 8.42E-09 4.32E-07 3.86E-07 168 Hr Anneal 70 4.00E-07 4.08E-07 4.18E-07 4.01E-07 4.09E-07 4.02E-07 3.91E-07 3.95E-07 3.80E-07 3.99E-07 3.53E-07 3.51E-07 4.39E-07 7.43E-09 4.59E-07 4.19E-07 4.37E-07 7.68E-09 4.58E-07 4.16E-07 4.07E-07 7.34E-09 4.27E-07 3.87E-07 3.65E-07 3.82E-07 4.20E-07 4.19E-07 3.93E-07 8.32E-09 9.16E-09 9.63E-09 1.01E-08 8.48E-09 3.88E-07 4.08E-07 4.46E-07 4.46E-07 4.17E-07 3.42E-07 3.57E-07 3.93E-07 3.91E-07 3.70E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07 PASS PASS PASS PASS PASS 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 280 50 4.33E-07 4.40E-07 4.49E-07 4.31E-07 4.42E-07 4.27E-07 4.18E-07 4.22E-07 4.04E-07 4.28E-07 3.53E-07 3.56E-07 24 Hr Anneal 60 4.30E-07 4.36E-07 4.48E-07 4.29E-07 4.40E-07 4.29E-07 4.17E-07 4.19E-07 4.03E-07 4.26E-07 3.54E-07 3.57E-07 -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.135. Plot of -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 281 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.135. Raw data for -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V Device 0 10 557 3.46E-07 3.61E-07 563 3.60E-07 3.82E-07 564 3.73E-07 4.03E-07 567 3.38E-07 3.67E-07 569 3.48E-07 3.79E-07 570 3.47E-07 3.53E-07 571 3.38E-07 3.45E-07 572 3.59E-07 3.67E-07 573 3.35E-07 3.39E-07 574 3.65E-07 3.71E-07 584 3.50E-07 3.50E-07 585 3.58E-07 3.61E-07 Biased Statistics Average Biased 3.53E-07 3.78E-07 Std Dev Biased 1.39E-08 1.62E-08 Ps90%/90% (+KTL) Biased 3.91E-07 4.23E-07 Ps90%/90% (-KTL) Biased 3.15E-07 3.34E-07 Un-Biased Statistics Average Un-Biased 3.49E-07 3.55E-07 Std Dev Un-Biased 1.32E-08 1.35E-08 Ps90%/90% (+KTL) Un-Biased 3.85E-07 3.92E-07 Ps90%/90% (-KTL) Un-Biased 3.13E-07 3.18E-07 Specification MIN -6.50E-07 -7.00E-07 Status PASS PASS Specification MAX 6.50E-07 7.00E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.83E-07 4.02E-07 4.01E-07 4.15E-07 4.25E-07 4.38E-07 3.88E-07 4.02E-07 4.02E-07 4.17E-07 3.68E-07 3.87E-07 3.60E-07 3.77E-07 3.85E-07 4.02E-07 3.49E-07 3.69E-07 3.87E-07 4.07E-07 3.51E-07 3.50E-07 3.58E-07 3.61E-07 4.00E-07 1.63E-08 4.45E-07 3.55E-07 4.15E-07 1.48E-08 4.55E-07 3.74E-07 168 Hr Anneal 70 4.05E-07 4.16E-07 4.33E-07 3.99E-07 4.12E-07 3.96E-07 3.87E-07 4.11E-07 3.78E-07 4.19E-07 3.50E-07 3.60E-07 4.45E-07 1.44E-08 4.84E-07 4.05E-07 4.42E-07 1.53E-08 4.84E-07 4.00E-07 4.13E-07 1.26E-08 4.48E-07 3.78E-07 3.70E-07 3.88E-07 4.26E-07 4.24E-07 3.98E-07 1.62E-08 1.59E-08 1.79E-08 1.86E-08 1.67E-08 4.14E-07 4.32E-07 4.75E-07 4.75E-07 4.44E-07 3.25E-07 3.45E-07 3.76E-07 3.73E-07 3.52E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07 PASS PASS PASS PASS PASS 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 282 50 4.37E-07 4.45E-07 4.68E-07 4.30E-07 4.44E-07 4.24E-07 4.13E-07 4.39E-07 4.04E-07 4.48E-07 3.49E-07 3.65E-07 24 Hr Anneal 60 4.36E-07 4.41E-07 4.67E-07 4.26E-07 4.41E-07 4.21E-07 4.12E-07 4.38E-07 4.00E-07 4.46E-07 3.51E-07 3.66E-07 -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.136. Plot of -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 283 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.136. Raw data for -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V Device 0 10 557 3.47E-07 3.60E-07 563 3.54E-07 3.78E-07 564 3.55E-07 3.83E-07 567 3.57E-07 3.84E-07 569 3.58E-07 3.89E-07 570 3.54E-07 3.59E-07 571 3.51E-07 3.58E-07 572 3.57E-07 3.65E-07 573 3.48E-07 3.52E-07 574 3.48E-07 3.52E-07 584 3.41E-07 3.43E-07 585 3.62E-07 3.65E-07 Biased Statistics Average Biased 3.54E-07 3.79E-07 Std Dev Biased 4.39E-09 1.09E-08 Ps90%/90% (+KTL) Biased 3.66E-07 4.09E-07 Ps90%/90% (-KTL) Biased 3.42E-07 3.49E-07 Un-Biased Statistics Average Un-Biased 3.52E-07 3.57E-07 Std Dev Un-Biased 4.10E-09 5.47E-09 Ps90%/90% (+KTL) Un-Biased 3.63E-07 3.72E-07 Ps90%/90% (-KTL) Un-Biased 3.40E-07 3.42E-07 Specification MIN -6.50E-07 -7.00E-07 Status PASS PASS Specification MAX 6.50E-07 7.00E-07 Status PASS PASS Total Dose (krad(Si)) 20 30 3.83E-07 3.98E-07 4.00E-07 4.14E-07 4.07E-07 4.18E-07 4.08E-07 4.21E-07 4.14E-07 4.26E-07 3.76E-07 3.93E-07 3.75E-07 3.91E-07 3.83E-07 4.00E-07 3.68E-07 3.89E-07 3.69E-07 3.87E-07 3.44E-07 3.42E-07 3.61E-07 3.65E-07 4.02E-07 1.20E-08 4.35E-07 3.69E-07 4.15E-07 1.06E-08 4.45E-07 3.86E-07 168 Hr Anneal 70 4.04E-07 4.15E-07 4.16E-07 4.16E-07 4.22E-07 3.98E-07 4.02E-07 4.12E-07 3.98E-07 3.95E-07 3.42E-07 3.61E-07 4.47E-07 7.09E-09 4.66E-07 4.27E-07 4.45E-07 7.85E-09 4.67E-07 4.24E-07 4.15E-07 6.33E-09 4.32E-07 3.97E-07 3.74E-07 3.92E-07 4.28E-07 4.27E-07 4.01E-07 5.94E-09 5.20E-09 5.86E-09 6.16E-09 6.88E-09 3.90E-07 4.06E-07 4.44E-07 4.44E-07 4.20E-07 3.58E-07 3.78E-07 4.12E-07 4.10E-07 3.82E-07 -7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07 PASS PASS PASS PASS PASS 7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 284 50 4.35E-07 4.47E-07 4.49E-07 4.50E-07 4.53E-07 4.27E-07 4.27E-07 4.38E-07 4.23E-07 4.25E-07 3.43E-07 3.68E-07 24 Hr Anneal 60 4.33E-07 4.45E-07 4.48E-07 4.46E-07 4.54E-07 4.24E-07 4.29E-07 4.37E-07 4.24E-07 4.22E-07 3.43E-07 3.69E-07 Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.137. Plot of Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 285 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.137. Raw data for Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High4 1 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=0mA Device 0 10 20 30 50 60 70 557 4.92E-03 5.10E-03 5.16E-03 5.28E-03 5.24E-03 5.20E-03 5.14E-03 563 5.04E-03 5.42E-03 5.31E-03 5.28E-03 5.46E-03 5.61E-03 5.46E-03 564 5.14E-03 5.30E-03 5.44E-03 5.57E-03 5.55E-03 5.46E-03 5.49E-03 567 5.16E-03 5.42E-03 5.73E-03 5.42E-03 5.45E-03 5.66E-03 5.61E-03 569 5.01E-03 5.23E-03 5.21E-03 5.28E-03 5.55E-03 5.39E-03 5.26E-03 570 5.14E-03 5.18E-03 5.19E-03 5.22E-03 5.60E-03 5.30E-03 5.22E-03 571 5.29E-03 5.00E-03 5.19E-03 5.22E-03 5.67E-03 5.20E-03 5.22E-03 572 5.28E-03 5.25E-03 5.34E-03 5.40E-03 5.50E-03 5.42E-03 5.34E-03 573 5.18E-03 5.42E-03 5.48E-03 5.42E-03 5.55E-03 5.51E-03 5.32E-03 574 5.06E-03 5.00E-03 5.26E-03 4.98E-03 5.28E-03 5.30E-03 5.15E-03 584 4.82E-03 5.28E-03 5.17E-03 4.98E-03 5.14E-03 5.07E-03 4.87E-03 585 5.08E-03 5.08E-03 5.14E-03 5.15E-03 5.33E-03 5.10E-03 5.17E-03 Biased Statistics Average Biased 5.05E-03 5.29E-03 5.37E-03 5.37E-03 5.45E-03 5.46E-03 5.39E-03 Std Dev Biased 9.84E-05 1.36E-04 2.28E-04 1.29E-04 1.27E-04 1.84E-04 1.89E-04 Ps90%/90% (+KTL) Biased 5.32E-03 5.67E-03 5.99E-03 5.72E-03 5.80E-03 5.97E-03 5.91E-03 Ps90%/90% (-KTL) Biased 4.78E-03 4.92E-03 4.75E-03 5.01E-03 5.10E-03 4.96E-03 4.87E-03 Un-Biased Statistics Average Un-Biased 5.19E-03 5.17E-03 5.29E-03 5.25E-03 5.52E-03 5.35E-03 5.25E-03 Std Dev Un-Biased 9.70E-05 1.78E-04 1.22E-04 1.78E-04 1.48E-04 1.20E-04 7.87E-05 Ps90%/90% (+KTL) Un-Biased 5.46E-03 5.66E-03 5.63E-03 5.73E-03 5.93E-03 5.68E-03 5.47E-03 Ps90%/90% (-KTL) Un-Biased 4.92E-03 4.68E-03 4.96E-03 4.76E-03 5.11E-03 5.02E-03 5.03E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 286 Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.138. Plot of Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 287 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.138. Raw data for Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High4 2 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=0mA Device 0 10 20 30 50 60 70 557 4.86E-03 5.17E-03 5.09E-03 5.30E-03 5.31E-03 5.17E-03 5.09E-03 563 5.21E-03 5.65E-03 5.71E-03 5.50E-03 5.82E-03 5.68E-03 5.66E-03 564 5.34E-03 5.40E-03 5.71E-03 5.76E-03 5.63E-03 5.59E-03 5.49E-03 567 5.29E-03 5.40E-03 5.56E-03 5.54E-03 5.67E-03 5.57E-03 5.44E-03 569 5.11E-03 5.20E-03 5.29E-03 5.34E-03 5.51E-03 5.46E-03 5.32E-03 570 5.24E-03 5.37E-03 5.37E-03 5.39E-03 5.70E-03 5.36E-03 5.46E-03 571 5.14E-03 4.96E-03 5.16E-03 5.12E-03 5.68E-03 5.36E-03 5.10E-03 572 5.11E-03 5.20E-03 5.22E-03 5.23E-03 5.58E-03 5.25E-03 5.24E-03 573 5.21E-03 5.33E-03 5.64E-03 5.39E-03 5.46E-03 5.47E-03 5.24E-03 574 5.04E-03 5.06E-03 5.29E-03 4.98E-03 5.14E-03 5.37E-03 5.09E-03 584 5.31E-03 5.67E-03 5.48E-03 5.34E-03 5.43E-03 5.52E-03 5.32E-03 585 5.26E-03 5.35E-03 5.44E-03 5.42E-03 5.72E-03 5.37E-03 5.29E-03 Biased Statistics Average Biased 5.16E-03 5.36E-03 5.47E-03 5.49E-03 5.59E-03 5.49E-03 5.40E-03 Std Dev Biased 1.90E-04 1.93E-04 2.74E-04 1.83E-04 1.91E-04 1.97E-04 2.12E-04 Ps90%/90% (+KTL) Biased 5.68E-03 5.89E-03 6.22E-03 5.99E-03 6.11E-03 6.04E-03 5.98E-03 Ps90%/90% (-KTL) Biased 4.64E-03 4.83E-03 4.72E-03 4.99E-03 5.06E-03 4.95E-03 4.82E-03 Un-Biased Statistics Average Un-Biased 5.15E-03 5.18E-03 5.34E-03 5.22E-03 5.51E-03 5.36E-03 5.23E-03 Std Dev Un-Biased 7.98E-05 1.74E-04 1.87E-04 1.77E-04 2.29E-04 7.79E-05 1.50E-04 Ps90%/90% (+KTL) Un-Biased 5.37E-03 5.66E-03 5.85E-03 5.71E-03 6.14E-03 5.58E-03 5.64E-03 Ps90%/90% (-KTL) Un-Biased 4.93E-03 4.71E-03 4.82E-03 4.74E-03 4.88E-03 5.15E-03 4.82E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 288 Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.139. Plot of Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 289 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.139. Raw data for Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High4 3 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=0mA Device 0 10 20 30 50 60 70 557 4.81E-03 5.37E-03 5.21E-03 5.44E-03 5.28E-03 5.12E-03 5.31E-03 563 5.24E-03 5.64E-03 5.66E-03 5.60E-03 5.77E-03 5.94E-03 5.71E-03 564 5.23E-03 5.28E-03 5.64E-03 5.79E-03 5.62E-03 5.61E-03 5.54E-03 567 5.31E-03 5.35E-03 5.63E-03 5.54E-03 5.68E-03 5.51E-03 5.53E-03 569 5.16E-03 5.25E-03 5.29E-03 5.30E-03 5.48E-03 5.44E-03 5.26E-03 570 5.28E-03 5.33E-03 5.24E-03 5.44E-03 5.75E-03 5.39E-03 5.41E-03 571 5.13E-03 5.03E-03 5.43E-03 5.12E-03 5.68E-03 5.37E-03 5.22E-03 572 5.11E-03 5.13E-03 5.31E-03 5.30E-03 5.58E-03 5.22E-03 5.29E-03 573 5.26E-03 5.50E-03 5.51E-03 5.40E-03 5.72E-03 5.56E-03 5.29E-03 574 5.09E-03 5.03E-03 5.37E-03 5.18E-03 5.16E-03 5.25E-03 5.07E-03 584 5.29E-03 5.57E-03 5.54E-03 5.30E-03 5.43E-03 5.37E-03 5.31E-03 585 5.28E-03 5.38E-03 5.41E-03 5.42E-03 5.58E-03 5.37E-03 5.26E-03 Biased Statistics Average Biased 5.15E-03 5.38E-03 5.49E-03 5.53E-03 5.57E-03 5.52E-03 5.47E-03 Std Dev Biased 1.97E-04 1.54E-04 2.18E-04 1.83E-04 1.92E-04 2.96E-04 1.84E-04 Ps90%/90% (+KTL) Biased 5.69E-03 5.80E-03 6.08E-03 6.03E-03 6.09E-03 6.34E-03 5.98E-03 Ps90%/90% (-KTL) Biased 4.61E-03 4.95E-03 4.89E-03 5.03E-03 5.04E-03 4.71E-03 4.96E-03 Un-Biased Statistics Average Un-Biased 5.17E-03 5.20E-03 5.37E-03 5.29E-03 5.58E-03 5.36E-03 5.26E-03 Std Dev Un-Biased 8.91E-05 2.06E-04 1.04E-04 1.38E-04 2.42E-04 1.35E-04 1.24E-04 Ps90%/90% (+KTL) Un-Biased 5.42E-03 5.77E-03 5.66E-03 5.67E-03 6.24E-03 5.73E-03 5.60E-03 Ps90%/90% (-KTL) Un-Biased 4.93E-03 4.64E-03 5.09E-03 4.91E-03 4.91E-03 4.99E-03 4.91E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 290 Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.140. Plot of Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 291 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.140. Raw data for Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High4 4 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=0mA Device 0 10 20 30 50 60 70 557 4.99E-03 5.23E-03 5.05E-03 5.30E-03 5.38E-03 5.15E-03 5.39E-03 563 5.08E-03 5.35E-03 5.39E-03 5.49E-03 5.50E-03 5.59E-03 5.46E-03 564 5.21E-03 5.32E-03 5.53E-03 5.86E-03 5.50E-03 5.62E-03 5.39E-03 567 5.24E-03 5.45E-03 5.75E-03 5.55E-03 5.75E-03 5.54E-03 5.54E-03 569 5.33E-03 5.27E-03 5.43E-03 5.23E-03 5.56E-03 5.64E-03 5.29E-03 570 5.26E-03 5.32E-03 5.34E-03 5.37E-03 5.75E-03 5.34E-03 5.29E-03 571 5.24E-03 5.03E-03 5.32E-03 5.25E-03 5.68E-03 5.37E-03 5.22E-03 572 5.28E-03 5.35E-03 5.51E-03 5.39E-03 5.60E-03 5.39E-03 5.41E-03 573 5.24E-03 5.37E-03 5.56E-03 5.34E-03 5.70E-03 5.66E-03 5.37E-03 574 5.06E-03 4.96E-03 5.39E-03 5.28E-03 5.28E-03 5.24E-03 5.31E-03 584 5.09E-03 5.23E-03 5.29E-03 5.07E-03 5.14E-03 5.22E-03 5.09E-03 585 5.09E-03 5.03E-03 5.09E-03 5.30E-03 5.50E-03 5.15E-03 5.15E-03 Biased Statistics Average Biased 5.17E-03 5.32E-03 5.43E-03 5.49E-03 5.54E-03 5.51E-03 5.41E-03 Std Dev Biased 1.35E-04 8.41E-05 2.54E-04 2.47E-04 1.35E-04 2.04E-04 9.29E-05 Ps90%/90% (+KTL) Biased 5.54E-03 5.55E-03 6.13E-03 6.16E-03 5.91E-03 6.07E-03 5.67E-03 Ps90%/90% (-KTL) Biased 4.80E-03 5.09E-03 4.73E-03 4.81E-03 5.17E-03 4.95E-03 5.16E-03 Un-Biased Statistics Average Un-Biased 5.22E-03 5.21E-03 5.42E-03 5.33E-03 5.60E-03 5.40E-03 5.32E-03 Std Dev Un-Biased 8.88E-05 1.95E-04 1.06E-04 5.94E-05 1.88E-04 1.56E-04 7.35E-05 Ps90%/90% (+KTL) Un-Biased 5.46E-03 5.74E-03 5.71E-03 5.49E-03 6.12E-03 5.83E-03 5.52E-03 Ps90%/90% (-KTL) Un-Biased 4.97E-03 4.67E-03 5.13E-03 5.16E-03 5.09E-03 4.97E-03 5.12E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 292 Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.141. Plot of Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 293 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.141. Raw data for Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High5 1 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=1mA Device 0 10 20 30 50 60 70 557 6.83E-02 6.84E-02 6.87E-02 6.93E-02 6.93E-02 6.92E-02 6.88E-02 563 7.21E-02 7.29E-02 7.32E-02 7.36E-02 7.36E-02 7.34E-02 7.35E-02 564 7.31E-02 7.40E-02 7.49E-02 7.52E-02 7.51E-02 7.48E-02 7.46E-02 567 7.35E-02 7.44E-02 7.46E-02 7.50E-02 7.49E-02 7.49E-02 7.46E-02 569 7.16E-02 7.22E-02 7.29E-02 7.31E-02 7.33E-02 7.31E-02 7.25E-02 570 7.24E-02 7.26E-02 7.33E-02 7.34E-02 7.37E-02 7.36E-02 7.32E-02 571 7.20E-02 7.21E-02 7.24E-02 7.27E-02 7.34E-02 7.30E-02 7.28E-02 572 7.21E-02 7.21E-02 7.24E-02 7.31E-02 7.34E-02 7.30E-02 7.30E-02 573 7.33E-02 7.39E-02 7.43E-02 7.42E-02 7.46E-02 7.47E-02 7.41E-02 574 7.11E-02 7.08E-02 7.16E-02 7.16E-02 7.21E-02 7.19E-02 7.15E-02 584 6.89E-02 6.91E-02 6.92E-02 6.89E-02 6.89E-02 6.85E-02 6.87E-02 585 6.87E-02 6.88E-02 6.90E-02 6.90E-02 6.90E-02 6.83E-02 6.86E-02 Biased Statistics Average Biased 7.17E-02 7.24E-02 7.28E-02 7.32E-02 7.32E-02 7.31E-02 7.28E-02 Std Dev Biased 2.07E-03 2.36E-03 2.49E-03 2.35E-03 2.35E-03 2.33E-03 2.40E-03 Ps90%/90% (+KTL) Biased 7.74E-02 7.88E-02 7.97E-02 7.97E-02 7.97E-02 7.94E-02 7.94E-02 Ps90%/90% (-KTL) Biased 6.61E-02 6.59E-02 6.60E-02 6.68E-02 6.68E-02 6.67E-02 6.62E-02 Un-Biased Statistics Average Un-Biased 7.22E-02 7.23E-02 7.28E-02 7.30E-02 7.35E-02 7.32E-02 7.29E-02 Std Dev Un-Biased 7.94E-04 1.11E-03 1.04E-03 9.84E-04 8.91E-04 1.03E-03 9.17E-04 Ps90%/90% (+KTL) Un-Biased 7.44E-02 7.53E-02 7.57E-02 7.57E-02 7.59E-02 7.60E-02 7.54E-02 Ps90%/90% (-KTL) Un-Biased 7.00E-02 6.92E-02 7.00E-02 7.03E-02 7.10E-02 7.04E-02 7.04E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 294 Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.142. Plot of Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 295 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.142. Raw data for Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High5 2 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=1mA Device 0 10 20 30 50 60 70 557 6.56E-02 6.60E-02 6.59E-02 6.65E-02 6.66E-02 6.62E-02 6.63E-02 563 7.36E-02 7.40E-02 7.44E-02 7.48E-02 7.51E-02 7.50E-02 7.47E-02 564 7.29E-02 7.37E-02 7.46E-02 7.49E-02 7.47E-02 7.45E-02 7.43E-02 567 7.39E-02 7.47E-02 7.53E-02 7.55E-02 7.54E-02 7.53E-02 7.51E-02 569 7.05E-02 7.14E-02 7.16E-02 7.17E-02 7.19E-02 7.18E-02 7.15E-02 570 7.21E-02 7.25E-02 7.28E-02 7.31E-02 7.36E-02 7.30E-02 7.30E-02 571 7.08E-02 7.09E-02 7.12E-02 7.16E-02 7.23E-02 7.18E-02 7.17E-02 572 6.88E-02 6.90E-02 6.94E-02 6.97E-02 7.01E-02 6.97E-02 6.97E-02 573 7.33E-02 7.37E-02 7.43E-02 7.42E-02 7.46E-02 7.45E-02 7.39E-02 574 6.85E-02 6.85E-02 6.89E-02 6.92E-02 6.95E-02 6.95E-02 6.90E-02 584 7.21E-02 7.27E-02 7.26E-02 7.26E-02 7.22E-02 7.20E-02 7.19E-02 585 7.23E-02 7.25E-02 7.28E-02 7.26E-02 7.29E-02 7.22E-02 7.24E-02 Biased Statistics Average Biased 7.13E-02 7.20E-02 7.23E-02 7.27E-02 7.28E-02 7.25E-02 7.24E-02 Std Dev Biased 3.46E-03 3.56E-03 3.86E-03 3.74E-03 3.70E-03 3.83E-03 3.68E-03 Ps90%/90% (+KTL) Biased 8.08E-02 8.17E-02 8.29E-02 8.29E-02 8.29E-02 8.31E-02 8.24E-02 Ps90%/90% (-KTL) Biased 6.18E-02 6.22E-02 6.17E-02 6.24E-02 6.26E-02 6.20E-02 6.23E-02 Un-Biased Statistics Average Un-Biased 7.07E-02 7.09E-02 7.13E-02 7.15E-02 7.20E-02 7.17E-02 7.15E-02 Std Dev Un-Biased 2.06E-03 2.22E-03 2.25E-03 2.16E-03 2.18E-03 2.12E-03 2.09E-03 Ps90%/90% (+KTL) Un-Biased 7.63E-02 7.70E-02 7.75E-02 7.74E-02 7.80E-02 7.75E-02 7.72E-02 Ps90%/90% (-KTL) Un-Biased 6.51E-02 6.48E-02 6.52E-02 6.56E-02 6.60E-02 6.59E-02 6.57E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 296 Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.143. Plot of Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 297 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.143. Raw data for Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High5 3 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=1mA Device 0 10 20 30 50 60 70 557 6.58E-02 6.60E-02 6.62E-02 6.67E-02 6.67E-02 6.65E-02 6.66E-02 563 7.40E-02 7.47E-02 7.50E-02 7.53E-02 7.54E-02 7.53E-02 7.53E-02 564 7.26E-02 7.34E-02 7.39E-02 7.47E-02 7.44E-02 7.42E-02 7.41E-02 567 7.37E-02 7.45E-02 7.51E-02 7.53E-02 7.53E-02 7.52E-02 7.49E-02 569 7.06E-02 7.12E-02 7.16E-02 7.16E-02 7.21E-02 7.19E-02 7.13E-02 570 7.23E-02 7.26E-02 7.30E-02 7.32E-02 7.38E-02 7.35E-02 7.34E-02 571 7.08E-02 7.07E-02 7.13E-02 7.16E-02 7.23E-02 7.18E-02 7.15E-02 572 6.88E-02 6.91E-02 6.95E-02 6.97E-02 7.01E-02 6.99E-02 6.97E-02 573 7.34E-02 7.35E-02 7.43E-02 7.43E-02 7.47E-02 7.45E-02 7.43E-02 574 6.83E-02 6.77E-02 6.89E-02 6.89E-02 6.93E-02 6.92E-02 6.89E-02 584 7.25E-02 7.29E-02 7.29E-02 7.26E-02 7.26E-02 7.21E-02 7.23E-02 585 7.22E-02 7.25E-02 7.28E-02 7.26E-02 7.24E-02 7.19E-02 7.23E-02 Biased Statistics Average Biased 7.13E-02 7.20E-02 7.24E-02 7.27E-02 7.28E-02 7.26E-02 7.25E-02 Std Dev Biased 3.40E-03 3.61E-03 3.70E-03 3.69E-03 3.63E-03 3.68E-03 3.64E-03 Ps90%/90% (+KTL) Biased 8.07E-02 8.19E-02 8.25E-02 8.28E-02 8.27E-02 8.27E-02 8.24E-02 Ps90%/90% (-KTL) Biased 6.20E-02 6.21E-02 6.22E-02 6.26E-02 6.28E-02 6.25E-02 6.25E-02 Un-Biased Statistics Average Un-Biased 7.07E-02 7.07E-02 7.14E-02 7.15E-02 7.20E-02 7.18E-02 7.15E-02 Std Dev Un-Biased 2.20E-03 2.38E-03 2.25E-03 2.27E-03 2.31E-03 2.27E-03 2.33E-03 Ps90%/90% (+KTL) Un-Biased 7.67E-02 7.72E-02 7.76E-02 7.78E-02 7.84E-02 7.80E-02 7.79E-02 Ps90%/90% (-KTL) Un-Biased 6.47E-02 6.42E-02 6.52E-02 6.53E-02 6.57E-02 6.55E-02 6.51E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 298 Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.144. Plot of Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 299 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.144. Raw data for Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High5 4 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=1mA Device 0 10 20 30 50 60 70 557 6.81E-02 6.86E-02 6.90E-02 6.94E-02 6.93E-02 6.92E-02 6.90E-02 563 7.21E-02 7.27E-02 7.32E-02 7.33E-02 7.36E-02 7.37E-02 7.32E-02 564 7.35E-02 7.41E-02 7.49E-02 7.54E-02 7.50E-02 7.48E-02 7.47E-02 567 7.32E-02 7.42E-02 7.47E-02 7.46E-02 7.47E-02 7.47E-02 7.44E-02 569 7.18E-02 7.25E-02 7.27E-02 7.29E-02 7.34E-02 7.30E-02 7.28E-02 570 7.23E-02 7.26E-02 7.30E-02 7.31E-02 7.36E-02 7.35E-02 7.32E-02 571 7.18E-02 7.20E-02 7.23E-02 7.27E-02 7.34E-02 7.30E-02 7.26E-02 572 7.22E-02 7.20E-02 7.24E-02 7.30E-02 7.34E-02 7.28E-02 7.28E-02 573 7.34E-02 7.36E-02 7.40E-02 7.43E-02 7.46E-02 7.43E-02 7.40E-02 574 7.08E-02 7.05E-02 7.14E-02 7.14E-02 7.18E-02 7.16E-02 7.14E-02 584 6.88E-02 6.93E-02 6.91E-02 6.90E-02 6.88E-02 6.85E-02 6.86E-02 585 6.85E-02 6.87E-02 6.89E-02 6.89E-02 6.88E-02 6.81E-02 6.84E-02 Biased Statistics Average Biased 7.17E-02 7.24E-02 7.29E-02 7.31E-02 7.32E-02 7.31E-02 7.28E-02 Std Dev Biased 2.16E-03 2.28E-03 2.39E-03 2.30E-03 2.28E-03 2.33E-03 2.27E-03 Ps90%/90% (+KTL) Biased 7.76E-02 7.87E-02 7.94E-02 7.94E-02 7.94E-02 7.95E-02 7.90E-02 Ps90%/90% (-KTL) Biased 6.58E-02 6.62E-02 6.64E-02 6.68E-02 6.69E-02 6.67E-02 6.66E-02 Un-Biased Statistics Average Un-Biased 7.21E-02 7.21E-02 7.26E-02 7.29E-02 7.34E-02 7.30E-02 7.28E-02 Std Dev Un-Biased 9.54E-04 1.11E-03 9.49E-04 1.07E-03 1.01E-03 1.01E-03 9.39E-04 Ps90%/90% (+KTL) Un-Biased 7.47E-02 7.52E-02 7.52E-02 7.58E-02 7.61E-02 7.58E-02 7.53E-02 Ps90%/90% (-KTL) Un-Biased 6.95E-02 6.91E-02 7.00E-02 7.00E-02 7.06E-02 7.03E-02 7.02E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 300 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.145. Plot of Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 301 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.145. Raw data for Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High6 1 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=2.5mA Device 0 10 20 30 50 60 70 557 1.23E-01 1.23E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 563 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 564 1.31E-01 1.32E-01 1.32E-01 1.33E-01 1.32E-01 1.32E-01 1.32E-01 567 1.30E-01 1.31E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 569 1.28E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 570 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.31E-01 1.30E-01 1.30E-01 571 1.28E-01 1.28E-01 1.29E-01 1.29E-01 1.30E-01 1.29E-01 1.29E-01 572 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.31E-01 1.30E-01 1.30E-01 573 1.30E-01 1.31E-01 1.31E-01 1.31E-01 1.32E-01 1.31E-01 1.31E-01 574 1.27E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 584 1.24E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 585 1.24E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01 1.23E-01 1.24E-01 Biased Statistics Average Biased 1.28E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 Std Dev Biased 3.09E-03 3.36E-03 3.45E-03 3.45E-03 3.34E-03 3.34E-03 3.35E-03 Ps90%/90% (+KTL) Biased 1.37E-01 1.38E-01 1.39E-01 1.39E-01 1.39E-01 1.39E-01 1.39E-01 Ps90%/90% (-KTL) Biased 1.20E-01 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.20E-01 1.20E-01 Un-Biased Statistics Average Un-Biased 1.29E-01 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 Std Dev Un-Biased 1.27E-03 1.44E-03 1.30E-03 1.34E-03 1.37E-03 1.28E-03 1.18E-03 Ps90%/90% (+KTL) Un-Biased 1.32E-01 1.33E-01 1.33E-01 1.33E-01 1.34E-01 1.33E-01 1.33E-01 Ps90%/90% (-KTL) Un-Biased 1.25E-01 1.25E-01 1.26E-01 1.26E-01 1.26E-01 1.26E-01 1.26E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 302 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.146. Plot of Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 303 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.146. Raw data for Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High6 2 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=2.5mA Device 0 10 20 30 50 60 70 557 1.19E-01 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.20E-01 1.20E-01 563 1.31E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 564 1.30E-01 1.31E-01 1.32E-01 1.33E-01 1.32E-01 1.32E-01 1.32E-01 567 1.31E-01 1.32E-01 1.33E-01 1.33E-01 1.33E-01 1.33E-01 1.32E-01 569 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 570 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 571 1.27E-01 1.27E-01 1.27E-01 1.28E-01 1.29E-01 1.28E-01 1.27E-01 572 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.25E-01 1.25E-01 573 1.30E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 1.31E-01 1.31E-01 574 1.23E-01 1.23E-01 1.24E-01 1.25E-01 1.25E-01 1.24E-01 1.24E-01 584 1.29E-01 1.30E-01 1.30E-01 1.29E-01 1.29E-01 1.28E-01 1.29E-01 585 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.29E-01 1.28E-01 1.29E-01 Biased Statistics Average Biased 1.28E-01 1.28E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 Std Dev Biased 5.03E-03 5.24E-03 5.29E-03 5.30E-03 5.22E-03 5.40E-03 5.27E-03 Ps90%/90% (+KTL) Biased 1.41E-01 1.43E-01 1.44E-01 1.44E-01 1.44E-01 1.44E-01 1.43E-01 Ps90%/90% (-KTL) Biased 1.14E-01 1.14E-01 1.14E-01 1.15E-01 1.15E-01 1.14E-01 1.14E-01 Un-Biased Statistics Average Un-Biased 1.27E-01 1.27E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.27E-01 Std Dev Un-Biased 2.86E-03 3.05E-03 2.95E-03 2.87E-03 2.92E-03 3.06E-03 2.90E-03 Ps90%/90% (+KTL) Un-Biased 1.35E-01 1.35E-01 1.35E-01 1.36E-01 1.36E-01 1.36E-01 1.35E-01 Ps90%/90% (-KTL) Un-Biased 1.19E-01 1.18E-01 1.19E-01 1.20E-01 1.20E-01 1.19E-01 1.19E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 304 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.147. Plot of Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 305 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.147. Raw data for Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High6 3 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=2.5mA Device 0 10 20 30 50 60 70 557 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.21E-01 1.21E-01 1.21E-01 563 1.31E-01 1.32E-01 1.33E-01 1.33E-01 1.33E-01 1.33E-01 1.33E-01 564 1.30E-01 1.31E-01 1.32E-01 1.32E-01 1.32E-01 1.31E-01 1.31E-01 567 1.31E-01 1.32E-01 1.33E-01 1.33E-01 1.33E-01 1.32E-01 1.32E-01 569 1.26E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 570 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.31E-01 1.30E-01 1.30E-01 571 1.26E-01 1.26E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.27E-01 572 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.25E-01 1.25E-01 573 1.30E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 1.32E-01 1.31E-01 574 1.23E-01 1.23E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 584 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.29E-01 1.29E-01 1.29E-01 585 1.29E-01 1.29E-01 1.30E-01 1.29E-01 1.29E-01 1.28E-01 1.29E-01 Biased Statistics Average Biased 1.28E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 Std Dev Biased 4.85E-03 5.10E-03 5.17E-03 5.14E-03 5.14E-03 5.11E-03 5.06E-03 Ps90%/90% (+KTL) Biased 1.41E-01 1.42E-01 1.43E-01 1.44E-01 1.43E-01 1.43E-01 1.43E-01 Ps90%/90% (-KTL) Biased 1.14E-01 1.15E-01 1.15E-01 1.15E-01 1.15E-01 1.15E-01 1.15E-01 Un-Biased Statistics Average Un-Biased 1.27E-01 1.27E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.27E-01 Std Dev Un-Biased 3.08E-03 3.22E-03 2.93E-03 3.12E-03 3.22E-03 3.24E-03 3.13E-03 Ps90%/90% (+KTL) Un-Biased 1.35E-01 1.36E-01 1.35E-01 1.36E-01 1.37E-01 1.37E-01 1.36E-01 Ps90%/90% (-KTL) Un-Biased 1.18E-01 1.18E-01 1.19E-01 1.19E-01 1.19E-01 1.19E-01 1.19E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 306 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.148. Plot of Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 307 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.148. Raw data for Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing High6 4 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=2.5mA Device 0 10 20 30 50 60 70 557 1.23E-01 1.23E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 563 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 564 1.31E-01 1.32E-01 1.32E-01 1.33E-01 1.33E-01 1.32E-01 1.32E-01 567 1.30E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 569 1.28E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 570 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 571 1.28E-01 1.28E-01 1.29E-01 1.29E-01 1.30E-01 1.29E-01 1.29E-01 572 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.29E-01 1.30E-01 573 1.30E-01 1.30E-01 1.31E-01 1.32E-01 1.32E-01 1.31E-01 1.31E-01 574 1.27E-01 1.26E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.27E-01 584 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.23E-01 1.24E-01 585 1.24E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01 1.23E-01 1.24E-01 Biased Statistics Average Biased 1.28E-01 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.29E-01 1.29E-01 Std Dev Biased 3.13E-03 3.37E-03 3.54E-03 3.45E-03 3.45E-03 3.33E-03 3.41E-03 Ps90%/90% (+KTL) Biased 1.37E-01 1.38E-01 1.39E-01 1.39E-01 1.39E-01 1.39E-01 1.39E-01 Ps90%/90% (-KTL) Biased 1.20E-01 1.20E-01 1.20E-01 1.20E-01 1.20E-01 1.20E-01 1.20E-01 Un-Biased Statistics Average Un-Biased 1.29E-01 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.29E-01 1.29E-01 Std Dev Un-Biased 1.31E-03 1.47E-03 1.38E-03 1.46E-03 1.46E-03 1.33E-03 1.35E-03 Ps90%/90% (+KTL) Un-Biased 1.32E-01 1.33E-01 1.33E-01 1.34E-01 1.34E-01 1.33E-01 1.33E-01 Ps90%/90% (-KTL) Un-Biased 1.25E-01 1.25E-01 1.26E-01 1.26E-01 1.26E-01 1.26E-01 1.26E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 308 Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.149. Plot of Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 309 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.149. Raw data for Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low4 1 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=0mA Device 0 10 20 30 50 60 70 557 1.52E-02 1.53E-02 1.53E-02 1.56E-02 1.58E-02 1.56E-02 1.54E-02 563 1.49E-02 1.48E-02 1.51E-02 1.54E-02 1.54E-02 1.53E-02 1.51E-02 564 1.49E-02 1.51E-02 1.53E-02 1.54E-02 1.56E-02 1.53E-02 1.52E-02 567 1.49E-02 1.52E-02 1.53E-02 1.55E-02 1.55E-02 1.54E-02 1.53E-02 569 1.47E-02 1.50E-02 1.52E-02 1.52E-02 1.53E-02 1.53E-02 1.51E-02 570 1.50E-02 1.50E-02 1.52E-02 1.51E-02 1.53E-02 1.52E-02 1.51E-02 571 1.51E-02 1.51E-02 1.54E-02 1.54E-02 1.55E-02 1.54E-02 1.53E-02 572 1.52E-02 1.53E-02 1.55E-02 1.56E-02 1.57E-02 1.57E-02 1.54E-02 573 1.50E-02 1.51E-02 1.53E-02 1.53E-02 1.54E-02 1.53E-02 1.51E-02 574 1.50E-02 1.50E-02 1.52E-02 1.52E-02 1.55E-02 1.55E-02 1.51E-02 584 1.52E-02 1.53E-02 1.54E-02 1.52E-02 1.52E-02 1.51E-02 1.50E-02 585 1.51E-02 1.52E-02 1.56E-02 1.54E-02 1.54E-02 1.51E-02 1.50E-02 Biased Statistics Average Biased 1.49E-02 1.51E-02 1.53E-02 1.54E-02 1.55E-02 1.54E-02 1.52E-02 Std Dev Biased 2.07E-04 2.05E-04 9.76E-05 1.30E-04 1.79E-04 1.39E-04 1.38E-04 Ps90%/90% (+KTL) Biased 1.55E-02 1.57E-02 1.55E-02 1.58E-02 1.60E-02 1.58E-02 1.56E-02 Ps90%/90% (-KTL) Biased 1.43E-02 1.45E-02 1.50E-02 1.50E-02 1.50E-02 1.50E-02 1.49E-02 Un-Biased Statistics Average Un-Biased 1.51E-02 1.51E-02 1.53E-02 1.53E-02 1.55E-02 1.54E-02 1.52E-02 Std Dev Un-Biased 8.93E-05 1.36E-04 1.11E-04 1.72E-04 1.36E-04 1.89E-04 1.54E-04 Ps90%/90% (+KTL) Un-Biased 1.53E-02 1.55E-02 1.56E-02 1.58E-02 1.58E-02 1.59E-02 1.56E-02 Ps90%/90% (-KTL) Un-Biased 1.48E-02 1.47E-02 1.50E-02 1.49E-02 1.51E-02 1.49E-02 1.48E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 310 Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.150. Plot of Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 311 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.150. Raw data for Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low4 2 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=0mA Device 0 10 20 30 50 60 70 557 1.51E-02 1.53E-02 1.55E-02 1.55E-02 1.59E-02 1.55E-02 1.55E-02 563 1.52E-02 1.53E-02 1.56E-02 1.58E-02 1.57E-02 1.57E-02 1.55E-02 564 1.50E-02 1.54E-02 1.58E-02 1.58E-02 1.58E-02 1.55E-02 1.55E-02 567 1.51E-02 1.54E-02 1.56E-02 1.57E-02 1.57E-02 1.57E-02 1.54E-02 569 1.51E-02 1.54E-02 1.57E-02 1.59E-02 1.57E-02 1.56E-02 1.55E-02 570 1.52E-02 1.52E-02 1.54E-02 1.55E-02 1.58E-02 1.57E-02 1.53E-02 571 1.52E-02 1.52E-02 1.55E-02 1.55E-02 1.55E-02 1.55E-02 1.53E-02 572 1.52E-02 1.53E-02 1.55E-02 1.55E-02 1.57E-02 1.56E-02 1.56E-02 573 1.56E-02 1.56E-02 1.59E-02 1.59E-02 1.60E-02 1.60E-02 1.58E-02 574 1.52E-02 1.53E-02 1.55E-02 1.55E-02 1.56E-02 1.56E-02 1.54E-02 584 1.52E-02 1.52E-02 1.54E-02 1.55E-02 1.52E-02 1.51E-02 1.53E-02 585 1.52E-02 1.53E-02 1.57E-02 1.54E-02 1.55E-02 1.51E-02 1.52E-02 Biased Statistics Average Biased 1.51E-02 1.54E-02 1.56E-02 1.57E-02 1.58E-02 1.56E-02 1.55E-02 Std Dev Biased 8.72E-05 3.96E-05 1.17E-04 1.65E-04 8.38E-05 6.87E-05 6.62E-05 Ps90%/90% (+KTL) Biased 1.53E-02 1.55E-02 1.59E-02 1.62E-02 1.60E-02 1.58E-02 1.57E-02 Ps90%/90% (-KTL) Biased 1.49E-02 1.53E-02 1.53E-02 1.53E-02 1.55E-02 1.54E-02 1.53E-02 Un-Biased Statistics Average Un-Biased 1.53E-02 1.53E-02 1.55E-02 1.56E-02 1.57E-02 1.57E-02 1.55E-02 Std Dev Un-Biased 1.72E-04 1.76E-04 1.83E-04 1.72E-04 1.90E-04 1.92E-04 1.97E-04 Ps90%/90% (+KTL) Un-Biased 1.57E-02 1.58E-02 1.60E-02 1.60E-02 1.62E-02 1.62E-02 1.60E-02 Ps90%/90% (-KTL) Un-Biased 1.48E-02 1.48E-02 1.50E-02 1.51E-02 1.52E-02 1.51E-02 1.49E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 312 Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.151. Plot of Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 313 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.151. Raw data for Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low4 3 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=0mA Device 0 10 20 30 50 60 70 557 1.50E-02 1.50E-02 1.54E-02 1.52E-02 1.54E-02 1.53E-02 1.52E-02 563 1.49E-02 1.51E-02 1.51E-02 1.53E-02 1.54E-02 1.53E-02 1.51E-02 564 1.47E-02 1.51E-02 1.52E-02 1.53E-02 1.54E-02 1.53E-02 1.53E-02 567 1.47E-02 1.49E-02 1.51E-02 1.52E-02 1.52E-02 1.51E-02 1.49E-02 569 1.50E-02 1.53E-02 1.56E-02 1.56E-02 1.57E-02 1.55E-02 1.56E-02 570 1.47E-02 1.48E-02 1.50E-02 1.50E-02 1.49E-02 1.52E-02 1.49E-02 571 1.49E-02 1.52E-02 1.52E-02 1.53E-02 1.54E-02 1.54E-02 1.50E-02 572 1.48E-02 1.49E-02 1.52E-02 1.51E-02 1.52E-02 1.51E-02 1.51E-02 573 1.50E-02 1.51E-02 1.53E-02 1.54E-02 1.53E-02 1.54E-02 1.52E-02 574 1.50E-02 1.50E-02 1.53E-02 1.54E-02 1.56E-02 1.55E-02 1.54E-02 584 1.49E-02 1.49E-02 1.51E-02 1.52E-02 1.49E-02 1.49E-02 1.48E-02 585 1.49E-02 1.51E-02 1.54E-02 1.52E-02 1.52E-02 1.49E-02 1.49E-02 Biased Statistics Average Biased 1.49E-02 1.51E-02 1.53E-02 1.53E-02 1.54E-02 1.53E-02 1.52E-02 Std Dev Biased 1.57E-04 1.57E-04 2.19E-04 1.31E-04 1.88E-04 1.40E-04 2.35E-04 Ps90%/90% (+KTL) Biased 1.53E-02 1.55E-02 1.59E-02 1.57E-02 1.60E-02 1.57E-02 1.59E-02 Ps90%/90% (-KTL) Biased 1.44E-02 1.47E-02 1.47E-02 1.50E-02 1.49E-02 1.49E-02 1.46E-02 Un-Biased Statistics Average Un-Biased 1.49E-02 1.50E-02 1.52E-02 1.52E-02 1.53E-02 1.53E-02 1.51E-02 Std Dev Un-Biased 1.15E-04 1.54E-04 1.43E-04 1.74E-04 2.40E-04 1.61E-04 2.00E-04 Ps90%/90% (+KTL) Un-Biased 1.52E-02 1.54E-02 1.56E-02 1.57E-02 1.60E-02 1.58E-02 1.57E-02 Ps90%/90% (-KTL) Un-Biased 1.46E-02 1.46E-02 1.48E-02 1.47E-02 1.46E-02 1.49E-02 1.46E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 314 Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.152. Plot of Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 315 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.152. Raw data for Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low4 4 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=0mA Device 0 10 20 30 50 60 70 557 1.52E-02 1.54E-02 1.56E-02 1.56E-02 1.60E-02 1.57E-02 1.55E-02 563 1.49E-02 1.52E-02 1.56E-02 1.55E-02 1.56E-02 1.54E-02 1.53E-02 564 1.50E-02 1.54E-02 1.56E-02 1.57E-02 1.58E-02 1.56E-02 1.55E-02 567 1.51E-02 1.53E-02 1.56E-02 1.55E-02 1.57E-02 1.57E-02 1.54E-02 569 1.50E-02 1.52E-02 1.54E-02 1.55E-02 1.56E-02 1.54E-02 1.54E-02 570 1.52E-02 1.53E-02 1.55E-02 1.56E-02 1.54E-02 1.56E-02 1.54E-02 571 1.52E-02 1.53E-02 1.56E-02 1.56E-02 1.58E-02 1.57E-02 1.55E-02 572 1.53E-02 1.54E-02 1.54E-02 1.54E-02 1.57E-02 1.57E-02 1.54E-02 573 1.53E-02 1.54E-02 1.57E-02 1.56E-02 1.57E-02 1.58E-02 1.55E-02 574 1.51E-02 1.51E-02 1.52E-02 1.52E-02 1.55E-02 1.55E-02 1.53E-02 584 1.52E-02 1.52E-02 1.52E-02 1.53E-02 1.50E-02 1.52E-02 1.50E-02 585 1.52E-02 1.53E-02 1.57E-02 1.54E-02 1.55E-02 1.53E-02 1.53E-02 Biased Statistics Average Biased 1.51E-02 1.53E-02 1.56E-02 1.55E-02 1.57E-02 1.56E-02 1.54E-02 Std Dev Biased 1.10E-04 1.02E-04 7.22E-05 8.50E-05 1.54E-04 1.56E-04 7.77E-05 Ps90%/90% (+KTL) Biased 1.54E-02 1.56E-02 1.58E-02 1.58E-02 1.61E-02 1.60E-02 1.56E-02 Ps90%/90% (-KTL) Biased 1.48E-02 1.50E-02 1.54E-02 1.53E-02 1.53E-02 1.51E-02 1.52E-02 Un-Biased Statistics Average Un-Biased 1.52E-02 1.53E-02 1.55E-02 1.55E-02 1.56E-02 1.57E-02 1.54E-02 Std Dev Un-Biased 9.71E-05 1.18E-04 1.93E-04 1.63E-04 1.52E-04 1.26E-04 9.72E-05 Ps90%/90% (+KTL) Un-Biased 1.55E-02 1.56E-02 1.60E-02 1.59E-02 1.60E-02 1.60E-02 1.57E-02 Ps90%/90% (-KTL) Un-Biased 1.49E-02 1.50E-02 1.49E-02 1.50E-02 1.52E-02 1.53E-02 1.51E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 316 Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.153. Plot of Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 317 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.153. Raw data for Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low5 1 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=1mA Device 0 10 20 30 50 60 70 557 3.37E-02 3.39E-02 3.41E-02 3.41E-02 3.42E-02 3.40E-02 3.41E-02 563 3.33E-02 3.35E-02 3.38E-02 3.40E-02 3.39E-02 3.38E-02 3.37E-02 564 3.36E-02 3.37E-02 3.40E-02 3.40E-02 3.41E-02 3.39E-02 3.39E-02 567 3.34E-02 3.37E-02 3.39E-02 3.40E-02 3.40E-02 3.38E-02 3.38E-02 569 3.34E-02 3.36E-02 3.38E-02 3.39E-02 3.39E-02 3.37E-02 3.36E-02 570 3.34E-02 3.36E-02 3.37E-02 3.38E-02 3.38E-02 3.38E-02 3.36E-02 571 3.38E-02 3.38E-02 3.42E-02 3.41E-02 3.42E-02 3.41E-02 3.39E-02 572 3.39E-02 3.39E-02 3.40E-02 3.41E-02 3.41E-02 3.39E-02 3.40E-02 573 3.39E-02 3.39E-02 3.41E-02 3.42E-02 3.42E-02 3.43E-02 3.40E-02 574 3.37E-02 3.35E-02 3.39E-02 3.39E-02 3.41E-02 3.39E-02 3.38E-02 584 3.36E-02 3.37E-02 3.38E-02 3.39E-02 3.38E-02 3.37E-02 3.35E-02 585 3.38E-02 3.35E-02 3.40E-02 3.40E-02 3.37E-02 3.35E-02 3.36E-02 Biased Statistics Average Biased 3.35E-02 3.37E-02 3.39E-02 3.40E-02 3.40E-02 3.38E-02 3.38E-02 Std Dev Biased 1.76E-04 1.31E-04 1.44E-04 7.16E-05 1.39E-04 1.03E-04 1.95E-04 Ps90%/90% (+KTL) Biased 3.40E-02 3.40E-02 3.43E-02 3.42E-02 3.44E-02 3.41E-02 3.43E-02 Ps90%/90% (-KTL) Biased 3.30E-02 3.33E-02 3.35E-02 3.38E-02 3.36E-02 3.36E-02 3.33E-02 Un-Biased Statistics Average Un-Biased 3.37E-02 3.37E-02 3.40E-02 3.40E-02 3.41E-02 3.40E-02 3.38E-02 Std Dev Un-Biased 1.82E-04 1.67E-04 1.97E-04 1.28E-04 1.70E-04 2.02E-04 1.77E-04 Ps90%/90% (+KTL) Un-Biased 3.42E-02 3.42E-02 3.45E-02 3.44E-02 3.45E-02 3.45E-02 3.43E-02 Ps90%/90% (-KTL) Un-Biased 3.32E-02 3.33E-02 3.34E-02 3.37E-02 3.36E-02 3.34E-02 3.33E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 318 Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.154. Plot of Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 319 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.154. Raw data for Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low5 2 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=1mA Device 0 10 20 30 50 60 70 557 3.37E-02 3.37E-02 3.39E-02 3.41E-02 3.42E-02 3.40E-02 3.39E-02 563 3.41E-02 3.41E-02 3.42E-02 3.44E-02 3.46E-02 3.46E-02 3.44E-02 564 3.41E-02 3.44E-02 3.46E-02 3.47E-02 3.46E-02 3.44E-02 3.45E-02 567 3.41E-02 3.45E-02 3.45E-02 3.46E-02 3.47E-02 3.46E-02 3.45E-02 569 3.42E-02 3.43E-02 3.45E-02 3.46E-02 3.47E-02 3.44E-02 3.45E-02 570 3.42E-02 3.45E-02 3.44E-02 3.44E-02 3.44E-02 3.45E-02 3.44E-02 571 3.39E-02 3.41E-02 3.44E-02 3.44E-02 3.42E-02 3.43E-02 3.40E-02 572 3.40E-02 3.40E-02 3.42E-02 3.44E-02 3.43E-02 3.43E-02 3.41E-02 573 3.50E-02 3.48E-02 3.50E-02 3.51E-02 3.51E-02 3.51E-02 3.49E-02 574 3.38E-02 3.39E-02 3.41E-02 3.41E-02 3.41E-02 3.39E-02 3.39E-02 584 3.40E-02 3.40E-02 3.43E-02 3.41E-02 3.40E-02 3.39E-02 3.39E-02 585 3.41E-02 3.43E-02 3.46E-02 3.44E-02 3.42E-02 3.41E-02 3.41E-02 Biased Statistics Average Biased 3.40E-02 3.42E-02 3.43E-02 3.45E-02 3.45E-02 3.44E-02 3.44E-02 Std Dev Biased 2.17E-04 3.21E-04 2.87E-04 2.55E-04 1.82E-04 2.52E-04 2.72E-04 Ps90%/90% (+KTL) Biased 3.46E-02 3.51E-02 3.51E-02 3.52E-02 3.50E-02 3.51E-02 3.51E-02 Ps90%/90% (-KTL) Biased 3.34E-02 3.33E-02 3.36E-02 3.38E-02 3.40E-02 3.37E-02 3.36E-02 Un-Biased Statistics Average Un-Biased 3.42E-02 3.42E-02 3.44E-02 3.45E-02 3.44E-02 3.44E-02 3.43E-02 Std Dev Un-Biased 4.63E-04 3.78E-04 3.51E-04 3.80E-04 3.95E-04 4.41E-04 3.85E-04 Ps90%/90% (+KTL) Un-Biased 3.54E-02 3.53E-02 3.53E-02 3.55E-02 3.55E-02 3.56E-02 3.53E-02 Ps90%/90% (-KTL) Un-Biased 3.29E-02 3.32E-02 3.34E-02 3.34E-02 3.33E-02 3.32E-02 3.32E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 320 Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.155. Plot of Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 321 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.155. Raw data for Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low5 3 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=1mA Device 0 10 20 30 50 60 70 557 3.34E-02 3.33E-02 3.38E-02 3.36E-02 3.38E-02 3.37E-02 3.36E-02 563 3.35E-02 3.37E-02 3.39E-02 3.42E-02 3.41E-02 3.41E-02 3.40E-02 564 3.37E-02 3.39E-02 3.41E-02 3.41E-02 3.41E-02 3.38E-02 3.40E-02 567 3.37E-02 3.40E-02 3.42E-02 3.42E-02 3.41E-02 3.42E-02 3.39E-02 569 3.41E-02 3.44E-02 3.45E-02 3.45E-02 3.47E-02 3.44E-02 3.43E-02 570 3.31E-02 3.35E-02 3.38E-02 3.38E-02 3.38E-02 3.39E-02 3.36E-02 571 3.39E-02 3.39E-02 3.41E-02 3.41E-02 3.42E-02 3.40E-02 3.42E-02 572 3.37E-02 3.36E-02 3.38E-02 3.39E-02 3.39E-02 3.39E-02 3.38E-02 573 3.40E-02 3.41E-02 3.43E-02 3.44E-02 3.44E-02 3.44E-02 3.41E-02 574 3.36E-02 3.36E-02 3.40E-02 3.39E-02 3.40E-02 3.38E-02 3.38E-02 584 3.33E-02 3.37E-02 3.37E-02 3.37E-02 3.35E-02 3.34E-02 3.35E-02 585 3.38E-02 3.40E-02 3.41E-02 3.39E-02 3.38E-02 3.36E-02 3.37E-02 Biased Statistics Average Biased 3.37E-02 3.39E-02 3.41E-02 3.41E-02 3.41E-02 3.40E-02 3.39E-02 Std Dev Biased 2.62E-04 4.05E-04 2.57E-04 3.17E-04 3.17E-04 3.08E-04 2.60E-04 Ps90%/90% (+KTL) Biased 3.44E-02 3.50E-02 3.48E-02 3.50E-02 3.50E-02 3.49E-02 3.47E-02 Ps90%/90% (-KTL) Biased 3.30E-02 3.27E-02 3.34E-02 3.32E-02 3.33E-02 3.32E-02 3.32E-02 Un-Biased Statistics Average Un-Biased 3.37E-02 3.37E-02 3.40E-02 3.40E-02 3.41E-02 3.40E-02 3.39E-02 Std Dev Un-Biased 3.29E-04 2.66E-04 2.05E-04 2.57E-04 2.53E-04 2.35E-04 2.33E-04 Ps90%/90% (+KTL) Un-Biased 3.46E-02 3.45E-02 3.46E-02 3.47E-02 3.48E-02 3.47E-02 3.45E-02 Ps90%/90% (-KTL) Un-Biased 3.28E-02 3.30E-02 3.34E-02 3.33E-02 3.34E-02 3.34E-02 3.33E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 322 Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.156. Plot of Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 323 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.156. Raw data for Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low5 4 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=1mA Device 0 10 20 30 50 60 70 557 3.39E-02 3.41E-02 3.41E-02 3.43E-02 3.44E-02 3.42E-02 3.41E-02 563 3.40E-02 3.39E-02 3.40E-02 3.43E-02 3.43E-02 3.42E-02 3.41E-02 564 3.38E-02 3.41E-02 3.44E-02 3.44E-02 3.45E-02 3.42E-02 3.44E-02 567 3.39E-02 3.42E-02 3.43E-02 3.43E-02 3.44E-02 3.44E-02 3.42E-02 569 3.38E-02 3.40E-02 3.42E-02 3.42E-02 3.41E-02 3.41E-02 3.42E-02 570 3.42E-02 3.41E-02 3.43E-02 3.45E-02 3.44E-02 3.44E-02 3.42E-02 571 3.40E-02 3.43E-02 3.45E-02 3.45E-02 3.46E-02 3.44E-02 3.43E-02 572 3.41E-02 3.42E-02 3.42E-02 3.44E-02 3.45E-02 3.44E-02 3.42E-02 573 3.43E-02 3.44E-02 3.46E-02 3.47E-02 3.47E-02 3.48E-02 3.47E-02 574 3.39E-02 3.40E-02 3.42E-02 3.41E-02 3.44E-02 3.42E-02 3.40E-02 584 3.39E-02 3.40E-02 3.42E-02 3.40E-02 3.40E-02 3.38E-02 3.39E-02 585 3.39E-02 3.40E-02 3.45E-02 3.42E-02 3.41E-02 3.40E-02 3.40E-02 Biased Statistics Average Biased 3.39E-02 3.41E-02 3.42E-02 3.43E-02 3.43E-02 3.42E-02 3.42E-02 Std Dev Biased 6.66E-05 1.03E-04 1.76E-04 9.76E-05 1.74E-04 8.73E-05 1.18E-04 Ps90%/90% (+KTL) Biased 3.40E-02 3.43E-02 3.47E-02 3.46E-02 3.48E-02 3.45E-02 3.45E-02 Ps90%/90% (-KTL) Biased 3.37E-02 3.38E-02 3.37E-02 3.40E-02 3.39E-02 3.40E-02 3.39E-02 Un-Biased Statistics Average Un-Biased 3.41E-02 3.42E-02 3.43E-02 3.45E-02 3.45E-02 3.44E-02 3.43E-02 Std Dev Un-Biased 1.60E-04 1.63E-04 1.94E-04 2.10E-04 1.27E-04 2.04E-04 2.68E-04 Ps90%/90% (+KTL) Un-Biased 3.46E-02 3.47E-02 3.49E-02 3.50E-02 3.49E-02 3.50E-02 3.50E-02 Ps90%/90% (-KTL) Un-Biased 3.37E-02 3.38E-02 3.38E-02 3.39E-02 3.42E-02 3.39E-02 3.35E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 324 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.157. Plot of Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 325 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.157. Raw data for Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low6 1 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=2.5mA Device 0 10 20 30 50 60 70 557 7.31E-02 7.32E-02 7.34E-02 7.36E-02 7.35E-02 7.33E-02 7.34E-02 563 7.32E-02 7.32E-02 7.36E-02 7.38E-02 7.36E-02 7.34E-02 7.35E-02 564 7.34E-02 7.36E-02 7.39E-02 7.43E-02 7.39E-02 7.37E-02 7.38E-02 567 7.32E-02 7.37E-02 7.40E-02 7.38E-02 7.37E-02 7.35E-02 7.35E-02 569 7.31E-02 7.35E-02 7.35E-02 7.36E-02 7.35E-02 7.33E-02 7.34E-02 570 7.31E-02 7.31E-02 7.33E-02 7.34E-02 7.32E-02 7.34E-02 7.32E-02 571 7.37E-02 7.36E-02 7.40E-02 7.41E-02 7.40E-02 7.38E-02 7.37E-02 572 7.39E-02 7.38E-02 7.41E-02 7.40E-02 7.40E-02 7.39E-02 7.41E-02 573 7.40E-02 7.41E-02 7.43E-02 7.43E-02 7.41E-02 7.40E-02 7.39E-02 574 7.35E-02 7.32E-02 7.37E-02 7.38E-02 7.36E-02 7.34E-02 7.33E-02 584 7.30E-02 7.34E-02 7.35E-02 7.34E-02 7.31E-02 7.29E-02 7.31E-02 585 7.31E-02 7.33E-02 7.40E-02 7.35E-02 7.32E-02 7.29E-02 7.31E-02 Biased Statistics Average Biased 7.32E-02 7.34E-02 7.37E-02 7.38E-02 7.36E-02 7.34E-02 7.35E-02 Std Dev Biased 1.38E-04 2.29E-04 2.58E-04 2.68E-04 1.89E-04 1.53E-04 1.67E-04 Ps90%/90% (+KTL) Biased 7.36E-02 7.41E-02 7.44E-02 7.45E-02 7.42E-02 7.39E-02 7.39E-02 Ps90%/90% (-KTL) Biased 7.28E-02 7.28E-02 7.30E-02 7.31E-02 7.31E-02 7.30E-02 7.30E-02 Un-Biased Statistics Average Un-Biased 7.36E-02 7.36E-02 7.39E-02 7.39E-02 7.38E-02 7.37E-02 7.36E-02 Std Dev Un-Biased 3.52E-04 3.93E-04 3.58E-04 3.66E-04 3.50E-04 2.88E-04 3.75E-04 Ps90%/90% (+KTL) Un-Biased 7.46E-02 7.47E-02 7.48E-02 7.49E-02 7.47E-02 7.45E-02 7.47E-02 Ps90%/90% (-KTL) Un-Biased 7.27E-02 7.25E-02 7.29E-02 7.29E-02 7.28E-02 7.29E-02 7.26E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 326 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.158. Plot of Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 327 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.158. Raw data for Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low6 2 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=2.5mA Device 0 10 20 30 50 60 70 557 7.29E-02 7.30E-02 7.32E-02 7.32E-02 7.33E-02 7.30E-02 7.31E-02 563 7.44E-02 7.44E-02 7.47E-02 7.48E-02 7.47E-02 7.45E-02 7.47E-02 564 7.46E-02 7.47E-02 7.50E-02 7.52E-02 7.51E-02 7.46E-02 7.48E-02 567 7.46E-02 7.49E-02 7.51E-02 7.51E-02 7.50E-02 7.48E-02 7.48E-02 569 7.43E-02 7.46E-02 7.46E-02 7.48E-02 7.45E-02 7.45E-02 7.45E-02 570 7.44E-02 7.46E-02 7.47E-02 7.47E-02 7.46E-02 7.46E-02 7.44E-02 571 7.41E-02 7.40E-02 7.42E-02 7.43E-02 7.43E-02 7.42E-02 7.40E-02 572 7.38E-02 7.37E-02 7.40E-02 7.41E-02 7.41E-02 7.39E-02 7.37E-02 573 7.53E-02 7.52E-02 7.56E-02 7.56E-02 7.54E-02 7.54E-02 7.52E-02 574 7.32E-02 7.32E-02 7.35E-02 7.37E-02 7.37E-02 7.33E-02 7.33E-02 584 7.42E-02 7.43E-02 7.44E-02 7.45E-02 7.41E-02 7.39E-02 7.40E-02 585 7.42E-02 7.44E-02 7.50E-02 7.47E-02 7.47E-02 7.41E-02 7.42E-02 Biased Statistics Average Biased 7.41E-02 7.43E-02 7.45E-02 7.46E-02 7.45E-02 7.43E-02 7.44E-02 Std Dev Biased 7.28E-04 7.62E-04 7.57E-04 8.26E-04 7.29E-04 7.46E-04 7.24E-04 Ps90%/90% (+KTL) Biased 7.61E-02 7.64E-02 7.66E-02 7.69E-02 7.65E-02 7.63E-02 7.64E-02 Ps90%/90% (-KTL) Biased 7.22E-02 7.22E-02 7.24E-02 7.23E-02 7.25E-02 7.22E-02 7.24E-02 Un-Biased Statistics Average Un-Biased 7.42E-02 7.41E-02 7.44E-02 7.45E-02 7.44E-02 7.43E-02 7.41E-02 Std Dev Un-Biased 7.86E-04 7.82E-04 8.02E-04 7.36E-04 6.49E-04 7.95E-04 7.22E-04 Ps90%/90% (+KTL) Un-Biased 7.63E-02 7.63E-02 7.66E-02 7.65E-02 7.62E-02 7.64E-02 7.61E-02 Ps90%/90% (-KTL) Un-Biased 7.20E-02 7.20E-02 7.22E-02 7.25E-02 7.26E-02 7.21E-02 7.22E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 328 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.159. Plot of Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 329 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.159. Raw data for Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low6 3 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=2.5mA Device 0 10 20 30 50 60 70 557 7.23E-02 7.24E-02 7.27E-02 7.25E-02 7.29E-02 7.25E-02 7.24E-02 563 7.37E-02 7.36E-02 7.40E-02 7.42E-02 7.42E-02 7.38E-02 7.39E-02 564 7.35E-02 7.38E-02 7.40E-02 7.44E-02 7.41E-02 7.39E-02 7.41E-02 567 7.38E-02 7.41E-02 7.41E-02 7.43E-02 7.43E-02 7.41E-02 7.39E-02 569 7.38E-02 7.43E-02 7.44E-02 7.43E-02 7.40E-02 7.42E-02 7.42E-02 570 7.33E-02 7.34E-02 7.35E-02 7.36E-02 7.36E-02 7.35E-02 7.32E-02 571 7.37E-02 7.36E-02 7.40E-02 7.39E-02 7.40E-02 7.37E-02 7.38E-02 572 7.32E-02 7.31E-02 7.33E-02 7.34E-02 7.34E-02 7.31E-02 7.31E-02 573 7.42E-02 7.42E-02 7.45E-02 7.45E-02 7.44E-02 7.43E-02 7.43E-02 574 7.30E-02 7.30E-02 7.34E-02 7.34E-02 7.33E-02 7.32E-02 7.31E-02 584 7.30E-02 7.34E-02 7.35E-02 7.35E-02 7.32E-02 7.29E-02 7.30E-02 585 7.36E-02 7.36E-02 7.44E-02 7.41E-02 7.36E-02 7.33E-02 7.34E-02 Biased Statistics Average Biased 7.34E-02 7.36E-02 7.39E-02 7.39E-02 7.39E-02 7.37E-02 7.37E-02 Std Dev Biased 6.44E-04 7.25E-04 6.49E-04 8.10E-04 5.75E-04 7.03E-04 7.36E-04 Ps90%/90% (+KTL) Biased 7.52E-02 7.56E-02 7.56E-02 7.61E-02 7.55E-02 7.56E-02 7.57E-02 Ps90%/90% (-KTL) Biased 7.16E-02 7.16E-02 7.21E-02 7.17E-02 7.23E-02 7.18E-02 7.17E-02 Un-Biased Statistics Average Un-Biased 7.35E-02 7.35E-02 7.37E-02 7.38E-02 7.37E-02 7.36E-02 7.35E-02 Std Dev Un-Biased 4.67E-04 4.71E-04 5.17E-04 4.50E-04 4.42E-04 4.74E-04 5.25E-04 Ps90%/90% (+KTL) Un-Biased 7.48E-02 7.48E-02 7.51E-02 7.50E-02 7.49E-02 7.49E-02 7.49E-02 Ps90%/90% (-KTL) Un-Biased 7.22E-02 7.22E-02 7.23E-02 7.25E-02 7.25E-02 7.23E-02 7.20E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 330 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.160. Plot of Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 331 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.160. Raw data for Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr Output Voltage Swing Low6 4 5V (V) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V IL=2.5mA Device 0 10 20 30 50 60 70 557 7.34E-02 7.36E-02 7.38E-02 7.37E-02 7.38E-02 7.36E-02 7.34E-02 563 7.38E-02 7.37E-02 7.43E-02 7.44E-02 7.42E-02 7.40E-02 7.41E-02 564 7.40E-02 7.42E-02 7.46E-02 7.47E-02 7.47E-02 7.42E-02 7.45E-02 567 7.39E-02 7.44E-02 7.43E-02 7.46E-02 7.44E-02 7.43E-02 7.41E-02 569 7.37E-02 7.40E-02 7.41E-02 7.42E-02 7.39E-02 7.38E-02 7.40E-02 570 7.41E-02 7.44E-02 7.46E-02 7.45E-02 7.42E-02 7.44E-02 7.42E-02 571 7.42E-02 7.42E-02 7.47E-02 7.46E-02 7.47E-02 7.44E-02 7.43E-02 572 7.47E-02 7.45E-02 7.46E-02 7.46E-02 7.47E-02 7.45E-02 7.45E-02 573 7.49E-02 7.50E-02 7.51E-02 7.51E-02 7.49E-02 7.49E-02 7.48E-02 574 7.39E-02 7.39E-02 7.43E-02 7.43E-02 7.42E-02 7.39E-02 7.39E-02 584 7.35E-02 7.38E-02 7.39E-02 7.39E-02 7.37E-02 7.34E-02 7.35E-02 585 7.38E-02 7.38E-02 7.47E-02 7.42E-02 7.40E-02 7.36E-02 7.39E-02 Biased Statistics Average Biased 7.38E-02 7.40E-02 7.42E-02 7.43E-02 7.42E-02 7.40E-02 7.40E-02 Std Dev Biased 2.35E-04 3.45E-04 2.97E-04 3.84E-04 3.67E-04 2.82E-04 3.78E-04 Ps90%/90% (+KTL) Biased 7.44E-02 7.49E-02 7.50E-02 7.53E-02 7.52E-02 7.48E-02 7.51E-02 Ps90%/90% (-KTL) Biased 7.31E-02 7.30E-02 7.34E-02 7.32E-02 7.32E-02 7.32E-02 7.30E-02 Un-Biased Statistics Average Un-Biased 7.44E-02 7.44E-02 7.47E-02 7.46E-02 7.45E-02 7.44E-02 7.44E-02 Std Dev Un-Biased 4.28E-04 3.92E-04 3.10E-04 2.78E-04 3.30E-04 3.57E-04 3.16E-04 Ps90%/90% (+KTL) Un-Biased 7.55E-02 7.55E-02 7.55E-02 7.54E-02 7.54E-02 7.54E-02 7.52E-02 Ps90%/90% (-KTL) Un-Biased 7.32E-02 7.33E-02 7.38E-02 7.39E-02 7.36E-02 7.35E-02 7.35E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 332 Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.50E+05 1.00E+05 5.00E+04 0.00E+00 -5.00E+04 -1.00E+05 -1.50E+05 -2.00E+05 -2.50E+05 -3.00E+05 -3.50E+05 -4.00E+05 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.161. Plot of Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 333 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.161. Raw data for Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Total Dose (krad(Si)) 20 30 4.18E+03 7.12E+03 9.05E+04 2.83E+04 6.96E+03 8.23E+03 1.24E+04 1.37E+04 4.89E+03 5.26E+04 2.76E+03 2.75E+03 6.46E+03 5.48E+03 2.13E+03 7.46E+03 6.76E+03 1.04E+04 1.93E+04 2.07E+04 3.85E+03 3.92E+03 5.39E+03 6.88E+03 50 3.68E+03 4.63E+04 3.83E+03 1.48E+04 5.66E+03 2.35E+03 8.00E+03 3.25E+03 6.79E+03 1.07E+04 3.10E+03 1.07E+04 24 Hr Anneal 60 7.65E+03 2.93E+04 7.53E+03 6.42E+03 9.16E+03 3.69E+03 8.99E+03 7.28E+03 5.49E+03 4.18E+04 3.05E+03 1.12E+04 168 Hr Anneal 70 5.34E+03 1.74E+04 6.03E+03 3.79E+05 9.17E+03 3.33E+03 6.61E+03 4.20E+04 3.23E+03 1.28E+04 3.99E+03 7.21E+03 0 1.18E+04 3.67E+04 6.74E+03 1.53E+05 1.45E+04 2.49E+03 9.76E+03 1.27E+04 9.87E+03 1.21E+05 3.16E+03 5.11E+03 10 6.48E+03 9.32E+03 4.15E+03 2.25E+04 1.20E+04 3.13E+03 7.76E+03 5.68E+03 7.57E+03 4.18E+04 3.39E+03 6.59E+03 4.45E+04 6.16E+04 2.13E+05 -1.24E+05 1.09E+04 7.14E+03 3.05E+04 -8.67E+03 2.38E+04 3.74E+04 1.26E+05 -7.89E+04 2.20E+04 1.91E+04 7.43E+04 -3.03E+04 1.48E+04 1.82E+04 6.46E+04 -3.49E+04 1.20E+04 9.72E+03 3.87E+04 -1.46E+04 8.33E+04 1.65E+05 5.36E+05 -3.70E+05 3.12E+04 5.05E+04 1.70E+05 -1.07E+05 6.00E+02 PASS 1.32E+04 1.61E+04 5.74E+04 -3.10E+04 3.00E+02 PASS 7.48E+03 6.91E+03 2.64E+04 -1.15E+04 3.00E+02 PASS 9.36E+03 6.95E+03 2.84E+04 -9.68E+03 3.00E+02 PASS 6.22E+03 3.45E+03 1.57E+04 -3.23E+03 3.00E+02 PASS 1.35E+04 1.60E+04 5.73E+04 -3.04E+04 3.00E+02 PASS 1.36E+04 1.63E+04 5.84E+04 -3.12E+04 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 334 Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 6.00E+03 4.00E+03 2.00E+03 0.00E+00 -2.00E+03 -4.00E+03 -6.00E+03 -8.00E+03 -1.00E+04 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.162. Plot of Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 335 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.162. Raw data for Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.93E+03 1.38E+04 3.06E+03 2.73E+03 3.83E+03 2.20E+03 3.07E+03 2.73E+03 3.16E+03 3.60E+03 3.07E+03 1.92E+03 24 Hr Anneal 60 1.61E+03 4.27E+03 3.57E+03 2.86E+03 3.08E+03 3.06E+03 4.19E+03 1.95E+03 3.32E+03 3.07E+03 2.88E+03 2.11E+03 168 Hr Anneal 70 2.13E+03 4.30E+03 5.05E+03 2.68E+03 3.20E+03 2.56E+03 1.79E+03 2.19E+03 3.30E+03 3.01E+03 2.62E+03 1.94E+03 0 1.94E+03 5.73E+03 3.65E+03 2.88E+03 3.30E+03 3.05E+03 2.04E+03 2.24E+03 2.89E+03 3.03E+03 2.80E+03 2.00E+03 10 1.88E+03 4.10E+03 3.45E+03 2.75E+03 2.07E+03 2.99E+03 3.41E+03 2.13E+03 2.57E+03 3.16E+03 3.34E+03 2.09E+03 Total Dose (krad(Si)) 20 30 1.88E+03 1.93E+03 3.73E+03 4.27E+03 6.50E+03 3.27E+03 2.57E+03 2.68E+03 3.43E+03 2.90E+03 2.92E+03 2.65E+03 2.14E+03 2.85E+03 2.36E+03 1.83E+03 2.60E+03 3.00E+03 2.81E+03 3.11E+03 3.59E+03 3.16E+03 2.04E+03 2.08E+03 3.50E+03 1.40E+03 7.35E+03 -3.50E+02 2.85E+03 9.30E+02 5.40E+03 3.00E+02 3.62E+03 1.77E+03 8.47E+03 -1.22E+03 3.01E+03 8.56E+02 5.36E+03 6.61E+02 5.06E+03 4.91E+03 1.85E+04 -8.40E+03 3.08E+03 9.84E+02 5.78E+03 3.80E+02 3.47E+03 1.19E+03 6.74E+03 2.06E+02 2.65E+03 4.73E+02 3.94E+03 1.35E+03 6.00E+02 PASS 2.85E+03 5.06E+02 4.24E+03 1.47E+03 3.00E+02 PASS 2.57E+03 3.20E+02 3.44E+03 1.69E+03 3.00E+02 PASS 2.69E+03 5.11E+02 4.09E+03 1.29E+03 3.00E+02 PASS 2.95E+03 5.26E+02 4.39E+03 1.51E+03 3.00E+02 PASS 3.12E+03 7.99E+02 5.31E+03 9.24E+02 3.00E+02 PASS 2.57E+03 6.09E+02 4.24E+03 9.00E+02 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 336 Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 3.00E+03 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 -1.00E+03 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.163. Plot of Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 337 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.163. Raw data for Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.76E+03 2.00E+03 2.58E+03 2.23E+03 3.35E+03 2.00E+03 2.03E+03 1.69E+03 2.47E+03 3.04E+03 2.58E+03 2.12E+03 24 Hr Anneal 60 1.54E+03 2.15E+03 1.99E+03 2.49E+03 3.53E+03 3.64E+03 2.18E+03 1.60E+03 1.96E+03 3.16E+03 2.28E+03 2.32E+03 168 Hr Anneal 70 1.72E+03 2.36E+03 1.76E+03 2.53E+03 4.14E+03 2.10E+03 2.45E+03 1.68E+03 1.97E+03 3.42E+03 2.65E+03 2.15E+03 0 1.91E+03 2.67E+03 1.88E+03 2.77E+03 4.78E+03 2.42E+03 2.11E+03 1.65E+03 1.99E+03 3.35E+03 2.64E+03 2.17E+03 10 1.70E+03 2.36E+03 1.93E+03 2.55E+03 3.32E+03 2.41E+03 2.15E+03 1.71E+03 1.82E+03 2.89E+03 2.69E+03 1.90E+03 Total Dose (krad(Si)) 20 30 1.78E+03 2.08E+03 2.80E+03 3.08E+03 2.04E+03 2.05E+03 3.27E+03 2.40E+03 2.97E+03 3.27E+03 2.48E+03 2.18E+03 1.97E+03 2.11E+03 1.49E+03 1.94E+03 2.24E+03 1.88E+03 2.86E+03 3.07E+03 2.28E+03 2.22E+03 2.08E+03 2.41E+03 2.80E+03 1.18E+03 6.03E+03 -4.30E+02 2.37E+03 6.28E+02 4.09E+03 6.50E+02 2.57E+03 6.33E+02 4.31E+03 8.36E+02 2.58E+03 5.68E+02 4.14E+03 1.02E+03 2.38E+03 6.19E+02 4.08E+03 6.85E+02 2.34E+03 7.48E+02 4.39E+03 2.86E+02 2.50E+03 9.82E+02 5.20E+03 -1.91E+02 2.30E+03 6.49E+02 4.08E+03 5.24E+02 6.00E+02 PASS 2.20E+03 4.76E+02 3.50E+03 8.90E+02 3.00E+02 PASS 2.21E+03 5.19E+02 3.63E+03 7.84E+02 3.00E+02 PASS 2.24E+03 4.82E+02 3.56E+03 9.17E+02 3.00E+02 PASS 2.24E+03 5.24E+02 3.68E+03 8.09E+02 3.00E+02 PASS 2.51E+03 8.55E+02 4.85E+03 1.64E+02 3.00E+02 PASS 2.32E+03 6.71E+02 4.16E+03 4.84E+02 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 338 Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 8.00E+03 6.00E+03 4.00E+03 2.00E+03 0.00E+00 -2.00E+03 -4.00E+03 -6.00E+03 -8.00E+03 -1.00E+04 -1.20E+04 -1.40E+04 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.164. Plot of Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 339 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.164. Raw data for Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Total Dose (krad(Si)) 20 30 3.72E+03 4.39E+03 2.96E+03 3.51E+03 1.98E+03 1.89E+03 3.67E+03 4.12E+03 7.56E+03 7.76E+03 4.41E+03 3.90E+03 2.97E+03 2.74E+03 4.48E+03 4.37E+03 2.17E+03 2.11E+03 5.15E+03 5.48E+03 2.10E+03 2.17E+03 2.63E+03 2.30E+03 50 3.25E+03 5.35E+03 2.10E+03 4.01E+03 1.33E+04 6.65E+03 2.62E+03 4.88E+03 2.06E+03 7.22E+03 1.95E+03 2.55E+03 24 Hr Anneal 60 4.64E+03 2.64E+03 2.03E+03 3.08E+03 1.78E+04 6.34E+03 2.33E+03 3.77E+03 2.24E+03 4.72E+03 2.28E+03 2.27E+03 168 Hr Anneal 70 3.25E+03 3.70E+03 2.11E+03 3.10E+03 5.50E+03 5.56E+03 2.66E+03 5.39E+03 2.23E+03 5.16E+03 1.99E+03 2.02E+03 0 4.80E+03 3.64E+03 2.39E+03 3.20E+03 4.69E+03 6.43E+03 2.65E+03 4.42E+03 2.39E+03 5.72E+03 2.13E+03 2.61E+03 10 3.44E+03 3.88E+03 2.17E+03 3.63E+03 7.44E+03 9.20E+03 2.56E+03 3.91E+03 2.36E+03 5.54E+03 1.95E+03 2.82E+03 3.74E+03 1.02E+03 6.54E+03 9.51E+02 4.11E+03 1.97E+03 9.52E+03 -1.30E+03 3.98E+03 2.12E+03 9.80E+03 -1.84E+03 4.33E+03 2.15E+03 1.02E+04 -1.55E+03 5.60E+03 4.46E+03 1.78E+04 -6.63E+03 6.03E+03 6.63E+03 2.42E+04 -1.21E+04 3.53E+03 1.24E+03 6.95E+03 1.21E+02 4.32E+03 1.80E+03 9.26E+03 -6.16E+02 6.00E+02 PASS 4.71E+03 2.81E+03 1.24E+04 -3.00E+03 3.00E+02 PASS 3.84E+03 1.22E+03 7.19E+03 4.77E+02 3.00E+02 PASS 3.72E+03 1.33E+03 7.38E+03 6.12E+01 3.00E+02 PASS 4.69E+03 2.32E+03 1.10E+04 -1.67E+03 3.00E+02 PASS 3.88E+03 1.72E+03 8.60E+03 -8.42E+02 3.00E+02 PASS 4.20E+03 1.62E+03 8.63E+03 -2.32E+02 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 340 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V 1.00E+02 9.00E+01 8.00E+01 7.00E+01 6.00E+01 5.00E+01 4.00E+01 3.00E+01 2.00E+01 1.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.165. Plot of Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 341 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.165. Raw data for Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 8.52E+01 9.16E+01 8.71E+01 1.19E+02 8.33E+01 9.84E+01 8.87E+01 8.63E+01 9.59E+01 9.31E+01 8.71E+01 9.39E+01 24 Hr Anneal 60 8.52E+01 9.16E+01 8.71E+01 1.17E+02 8.33E+01 9.82E+01 8.87E+01 8.63E+01 9.60E+01 9.32E+01 8.71E+01 9.38E+01 168 Hr Anneal 70 8.53E+01 9.11E+01 8.73E+01 1.17E+02 8.35E+01 1.00E+02 8.86E+01 8.66E+01 9.62E+01 9.30E+01 8.71E+01 9.39E+01 0 8.50E+01 9.18E+01 8.72E+01 1.15E+02 8.34E+01 1.00E+02 8.95E+01 8.67E+01 9.45E+01 9.41E+01 8.74E+01 9.46E+01 10 8.50E+01 9.18E+01 8.73E+01 1.17E+02 8.35E+01 1.00E+02 8.94E+01 8.66E+01 9.47E+01 9.40E+01 8.73E+01 9.41E+01 Total Dose (krad(Si)) 20 30 8.51E+01 8.52E+01 9.18E+01 9.19E+01 8.73E+01 8.73E+01 1.18E+02 1.20E+02 8.34E+01 8.35E+01 9.98E+01 9.96E+01 8.92E+01 8.91E+01 8.65E+01 8.65E+01 9.48E+01 9.50E+01 9.39E+01 9.37E+01 8.72E+01 8.72E+01 9.41E+01 9.40E+01 9.25E+01 1.29E+01 1.28E+02 5.71E+01 9.29E+01 1.37E+01 1.31E+02 5.52E+01 9.32E+01 1.45E+01 1.33E+02 5.36E+01 9.35E+01 1.50E+01 1.35E+02 5.23E+01 9.33E+01 1.48E+01 1.34E+02 5.27E+01 9.28E+01 1.38E+01 1.31E+02 5.49E+01 9.28E+01 1.37E+01 1.30E+02 5.52E+01 9.30E+01 5.21E+00 1.07E+02 7.88E+01 7.60E+01 PASS 9.29E+01 5.19E+00 1.07E+02 7.87E+01 7.00E+01 PASS 9.28E+01 5.16E+00 1.07E+02 7.87E+01 7.00E+01 PASS 9.28E+01 5.14E+00 1.07E+02 7.87E+01 7.00E+01 PASS 9.25E+01 4.99E+00 1.06E+02 7.88E+01 7.00E+01 PASS 9.25E+01 4.99E+00 1.06E+02 7.88E+01 7.00E+01 PASS 9.29E+01 5.62E+00 1.08E+02 7.75E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 342 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.166. Plot of Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 343 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.166. Raw data for Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 8.45E+01 9.36E+01 9.07E+01 8.70E+01 8.24E+01 1.13E+02 1.10E+02 8.71E+01 8.48E+01 9.49E+01 8.17E+01 8.43E+01 24 Hr Anneal 60 8.45E+01 9.36E+01 9.06E+01 8.70E+01 8.23E+01 1.13E+02 1.09E+02 8.71E+01 8.48E+01 9.50E+01 8.16E+01 8.42E+01 168 Hr Anneal 70 8.44E+01 9.43E+01 9.11E+01 8.75E+01 8.24E+01 1.19E+02 1.10E+02 8.72E+01 8.49E+01 9.47E+01 8.16E+01 8.42E+01 0 8.44E+01 9.38E+01 9.08E+01 8.71E+01 8.22E+01 1.39E+02 1.17E+02 8.73E+01 8.51E+01 9.37E+01 8.18E+01 8.44E+01 10 8.44E+01 9.36E+01 9.09E+01 8.72E+01 8.22E+01 1.34E+02 1.14E+02 8.72E+01 8.50E+01 9.39E+01 8.17E+01 8.43E+01 Total Dose (krad(Si)) 20 30 8.45E+01 8.45E+01 9.37E+01 9.37E+01 9.08E+01 9.09E+01 8.72E+01 8.72E+01 8.23E+01 8.23E+01 1.27E+02 1.21E+02 1.14E+02 1.14E+02 8.72E+01 8.71E+01 8.50E+01 8.49E+01 9.41E+01 9.41E+01 8.17E+01 8.16E+01 8.43E+01 8.42E+01 8.76E+01 4.71E+00 1.01E+02 7.47E+01 8.77E+01 4.64E+00 1.00E+02 7.49E+01 8.77E+01 4.63E+00 1.00E+02 7.50E+01 8.77E+01 4.65E+00 1.00E+02 7.50E+01 8.76E+01 4.55E+00 1.00E+02 7.51E+01 8.76E+01 4.54E+00 1.00E+02 7.52E+01 8.79E+01 4.84E+00 1.01E+02 7.46E+01 1.04E+02 2.29E+01 1.67E+02 4.15E+01 7.60E+01 PASS 1.03E+02 2.07E+01 1.59E+02 4.60E+01 7.00E+01 PASS 1.02E+02 1.85E+01 1.52E+02 5.09E+01 7.00E+01 PASS 1.00E+02 1.64E+01 1.45E+02 5.53E+01 7.00E+01 PASS 9.80E+01 1.30E+01 1.34E+02 6.24E+01 7.00E+01 PASS 9.78E+01 1.27E+01 1.33E+02 6.29E+01 7.00E+01 PASS 9.92E+01 1.49E+01 1.40E+02 5.84E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 344 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.167. Plot of Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 345 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.167. Raw data for Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 8.63E+01 8.72E+01 8.55E+01 8.75E+01 9.12E+01 8.35E+01 8.61E+01 1.29E+02 9.36E+01 9.71E+01 1.13E+02 9.20E+01 24 Hr Anneal 60 8.63E+01 8.71E+01 8.55E+01 8.75E+01 9.11E+01 8.35E+01 8.61E+01 1.28E+02 9.37E+01 9.74E+01 1.12E+02 9.19E+01 168 Hr Anneal 70 8.64E+01 8.73E+01 8.56E+01 8.75E+01 9.16E+01 8.39E+01 8.64E+01 1.34E+02 9.33E+01 9.83E+01 1.12E+02 9.20E+01 0 8.66E+01 8.72E+01 8.56E+01 8.72E+01 9.14E+01 8.36E+01 8.66E+01 1.12E+02 9.45E+01 9.56E+01 1.20E+02 9.26E+01 10 8.65E+01 8.72E+01 8.56E+01 8.74E+01 9.14E+01 8.35E+01 8.65E+01 1.16E+02 9.42E+01 9.59E+01 1.17E+02 9.21E+01 Total Dose (krad(Si)) 20 30 8.66E+01 8.65E+01 8.71E+01 8.72E+01 8.56E+01 8.56E+01 8.74E+01 8.74E+01 9.13E+01 9.14E+01 8.35E+01 8.35E+01 8.64E+01 8.63E+01 1.17E+02 1.20E+02 9.42E+01 9.41E+01 9.61E+01 9.64E+01 1.16E+02 1.16E+02 9.22E+01 9.21E+01 8.76E+01 2.24E+00 9.38E+01 8.15E+01 8.76E+01 2.23E+00 9.38E+01 8.15E+01 8.76E+01 2.19E+00 9.36E+01 8.16E+01 8.76E+01 2.21E+00 9.37E+01 8.16E+01 8.75E+01 2.17E+00 9.35E+01 8.16E+01 8.75E+01 2.16E+00 9.34E+01 8.16E+01 8.77E+01 2.33E+00 9.41E+01 8.13E+01 9.43E+01 1.09E+01 1.24E+02 6.45E+01 7.60E+01 PASS 9.52E+01 1.27E+01 1.30E+02 6.03E+01 7.00E+01 PASS 9.55E+01 1.33E+01 1.32E+02 5.91E+01 7.00E+01 PASS 9.61E+01 1.46E+01 1.36E+02 5.62E+01 7.00E+01 PASS 9.80E+01 1.85E+01 1.49E+02 4.74E+01 7.00E+01 PASS 9.78E+01 1.79E+01 1.47E+02 4.86E+01 7.00E+01 PASS 9.92E+01 2.04E+01 1.55E+02 4.32E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 346 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.168. Plot of Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 347 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.168. Raw data for Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 8.90E+01 9.84E+01 1.03E+02 9.96E+01 1.00E+02 1.16E+02 9.11E+01 9.48E+01 9.91E+01 8.57E+01 8.78E+01 8.93E+01 24 Hr Anneal 60 8.91E+01 9.80E+01 1.04E+02 9.98E+01 9.99E+01 1.16E+02 9.12E+01 9.49E+01 9.90E+01 8.57E+01 8.77E+01 8.91E+01 168 Hr Anneal 70 8.91E+01 9.90E+01 1.01E+02 9.89E+01 1.03E+02 1.14E+02 9.19E+01 9.53E+01 9.84E+01 8.54E+01 8.77E+01 8.91E+01 0 8.88E+01 9.90E+01 1.04E+02 9.90E+01 9.97E+01 1.26E+02 9.18E+01 9.69E+01 1.00E+02 8.59E+01 8.80E+01 8.96E+01 10 8.88E+01 9.88E+01 1.03E+02 9.88E+01 1.00E+02 1.28E+02 9.18E+01 9.63E+01 9.97E+01 8.59E+01 8.79E+01 8.92E+01 Total Dose (krad(Si)) 20 30 8.87E+01 8.88E+01 9.89E+01 9.92E+01 1.03E+02 1.03E+02 9.89E+01 9.89E+01 1.00E+02 1.00E+02 1.36E+02 1.33E+02 9.16E+01 9.15E+01 9.60E+01 9.57E+01 1.00E+02 1.00E+02 8.59E+01 8.58E+01 8.79E+01 8.78E+01 8.92E+01 8.92E+01 9.81E+01 5.63E+00 1.14E+02 8.27E+01 9.80E+01 5.45E+00 1.13E+02 8.30E+01 9.81E+01 5.55E+00 1.13E+02 8.29E+01 9.81E+01 5.41E+00 1.13E+02 8.32E+01 9.81E+01 5.42E+00 1.13E+02 8.32E+01 9.83E+01 5.66E+00 1.14E+02 8.27E+01 9.83E+01 5.41E+00 1.13E+02 8.34E+01 1.00E+02 1.56E+01 1.43E+02 5.74E+01 7.60E+01 PASS 1.00E+02 1.63E+01 1.45E+02 5.56E+01 7.00E+01 PASS 1.02E+02 1.99E+01 1.57E+02 4.73E+01 7.00E+01 PASS 1.01E+02 1.84E+01 1.52E+02 5.07E+01 7.00E+01 PASS 9.74E+01 1.16E+01 1.29E+02 6.55E+01 7.00E+01 PASS 9.74E+01 1.16E+01 1.29E+02 6.56E+01 7.00E+01 PASS 9.69E+01 1.05E+01 1.26E+02 6.82E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 348 CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.00E+02 9.00E+01 8.00E+01 7.00E+01 6.00E+01 5.00E+01 4.00E+01 3.00E+01 2.00E+01 1.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.169. Plot of CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 349 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.169. Raw data for CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 8.09E+01 9.69E+01 8.59E+01 9.87E+01 8.47E+01 9.96E+01 1.01E+02 9.05E+01 9.13E+01 9.05E+01 1.10E+02 9.70E+01 24 Hr Anneal 60 8.09E+01 9.72E+01 8.60E+01 9.87E+01 8.47E+01 9.94E+01 1.01E+02 9.03E+01 9.14E+01 9.04E+01 1.10E+02 9.66E+01 168 Hr Anneal 70 8.10E+01 9.56E+01 8.57E+01 9.79E+01 8.45E+01 1.03E+02 9.85E+01 9.05E+01 9.13E+01 9.02E+01 1.10E+02 9.67E+01 0 8.07E+01 9.68E+01 8.60E+01 9.77E+01 8.49E+01 9.99E+01 1.02E+02 9.00E+01 9.08E+01 9.02E+01 1.10E+02 9.67E+01 10 8.07E+01 9.68E+01 8.60E+01 9.78E+01 8.49E+01 9.97E+01 1.02E+02 9.00E+01 9.08E+01 9.02E+01 1.10E+02 9.64E+01 Total Dose (krad(Si)) 20 30 8.07E+01 8.08E+01 9.69E+01 9.68E+01 8.60E+01 8.60E+01 9.80E+01 9.81E+01 8.48E+01 8.48E+01 9.99E+01 9.98E+01 1.02E+02 1.01E+02 9.01E+01 9.02E+01 9.10E+01 9.12E+01 9.03E+01 9.03E+01 1.10E+02 1.10E+02 9.65E+01 9.66E+01 8.92E+01 7.60E+00 1.10E+02 6.84E+01 8.92E+01 7.64E+00 1.10E+02 6.83E+01 8.93E+01 7.74E+00 1.10E+02 6.81E+01 8.93E+01 7.72E+00 1.10E+02 6.81E+01 8.94E+01 7.91E+00 1.11E+02 6.77E+01 8.95E+01 7.94E+00 1.11E+02 6.77E+01 8.89E+01 7.39E+00 1.09E+02 6.86E+01 9.46E+01 5.94E+00 1.11E+02 7.83E+01 7.50E+01 PASS 9.45E+01 5.80E+00 1.10E+02 7.86E+01 7.00E+01 PASS 9.46E+01 5.70E+00 1.10E+02 7.90E+01 7.00E+01 PASS 9.46E+01 5.56E+00 1.10E+02 7.93E+01 7.00E+01 PASS 9.46E+01 5.24E+00 1.09E+02 8.02E+01 7.00E+01 PASS 9.44E+01 5.17E+00 1.09E+02 8.03E+01 7.00E+01 PASS 9.46E+01 5.61E+00 1.10E+02 7.92E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 350 CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.170. Plot of CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 351 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.170. Raw data for CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 9.90E+01 9.28E+01 9.25E+01 1.11E+02 8.63E+01 8.38E+01 8.67E+01 8.72E+01 8.87E+01 1.08E+02 8.19E+01 8.88E+01 24 Hr Anneal 60 9.90E+01 9.27E+01 9.24E+01 1.11E+02 8.63E+01 8.38E+01 8.67E+01 8.72E+01 8.86E+01 1.07E+02 8.19E+01 8.89E+01 168 Hr Anneal 70 9.80E+01 9.24E+01 9.22E+01 1.30E+02 8.60E+01 8.40E+01 8.70E+01 8.73E+01 8.90E+01 1.04E+02 8.19E+01 8.88E+01 0 9.72E+01 9.27E+01 9.24E+01 1.21E+02 8.58E+01 8.36E+01 8.69E+01 8.68E+01 8.87E+01 1.08E+02 8.19E+01 8.87E+01 10 9.77E+01 9.29E+01 9.24E+01 1.19E+02 8.59E+01 8.36E+01 8.69E+01 8.69E+01 8.87E+01 1.08E+02 8.18E+01 8.88E+01 Total Dose (krad(Si)) 20 30 9.79E+01 9.82E+01 9.26E+01 9.27E+01 9.25E+01 9.24E+01 1.18E+02 1.17E+02 8.61E+01 8.61E+01 8.36E+01 8.36E+01 8.67E+01 8.67E+01 8.69E+01 8.70E+01 8.86E+01 8.86E+01 1.08E+02 1.07E+02 8.18E+01 8.18E+01 8.87E+01 8.87E+01 9.79E+01 1.37E+01 1.35E+02 6.04E+01 9.76E+01 1.28E+01 1.33E+02 6.26E+01 9.74E+01 1.23E+01 1.31E+02 6.38E+01 9.73E+01 1.19E+01 1.30E+02 6.46E+01 9.63E+01 9.41E+00 1.22E+02 7.05E+01 9.64E+01 9.51E+00 1.22E+02 7.03E+01 9.96E+01 1.73E+01 1.47E+02 5.23E+01 9.08E+01 9.78E+00 1.18E+02 6.39E+01 7.50E+01 PASS 9.07E+01 9.66E+00 1.17E+02 6.42E+01 7.00E+01 PASS 9.07E+01 9.65E+00 1.17E+02 6.42E+01 7.00E+01 PASS 9.05E+01 9.33E+00 1.16E+02 6.49E+01 7.00E+01 PASS 9.08E+01 9.70E+00 1.17E+02 6.43E+01 7.00E+01 PASS 9.07E+01 9.43E+00 1.17E+02 6.49E+01 7.00E+01 PASS 9.03E+01 8.02E+00 1.12E+02 6.83E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 352 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.171. Plot of Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 353 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.171. Raw data for Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.29E+02 1.12E+02 1.17E+02 1.18E+02 1.18E+02 1.10E+02 1.27E+02 1.11E+02 1.11E+02 1.22E+02 1.13E+02 1.15E+02 24 Hr Anneal 60 1.29E+02 1.12E+02 1.17E+02 1.18E+02 1.18E+02 1.10E+02 1.27E+02 1.11E+02 1.11E+02 1.22E+02 1.13E+02 1.15E+02 168 Hr Anneal 70 1.29E+02 1.12E+02 1.17E+02 1.18E+02 1.18E+02 1.10E+02 1.25E+02 1.11E+02 1.11E+02 1.22E+02 1.13E+02 1.15E+02 0 1.28E+02 1.12E+02 1.16E+02 1.18E+02 1.18E+02 1.10E+02 1.25E+02 1.11E+02 1.11E+02 1.22E+02 1.13E+02 1.15E+02 10 1.29E+02 1.12E+02 1.16E+02 1.18E+02 1.18E+02 1.10E+02 1.25E+02 1.11E+02 1.11E+02 1.22E+02 1.13E+02 1.15E+02 Total Dose (krad(Si)) 20 30 1.29E+02 1.29E+02 1.12E+02 1.12E+02 1.17E+02 1.17E+02 1.18E+02 1.18E+02 1.18E+02 1.18E+02 1.10E+02 1.10E+02 1.25E+02 1.25E+02 1.11E+02 1.11E+02 1.11E+02 1.11E+02 1.22E+02 1.22E+02 1.13E+02 1.13E+02 1.15E+02 1.15E+02 1.18E+02 5.93E+00 1.35E+02 1.02E+02 1.18E+02 6.20E+00 1.35E+02 1.01E+02 1.19E+02 6.16E+00 1.35E+02 1.02E+02 1.19E+02 6.16E+00 1.35E+02 1.02E+02 1.19E+02 6.41E+00 1.36E+02 1.01E+02 1.19E+02 6.14E+00 1.35E+02 1.02E+02 1.19E+02 6.43E+00 1.36E+02 1.01E+02 1.16E+02 6.98E+00 1.35E+02 9.67E+01 8.80E+01 PASS 1.16E+02 6.79E+00 1.34E+02 9.72E+01 8.80E+01 PASS 1.16E+02 7.15E+00 1.36E+02 9.63E+01 8.80E+01 PASS 1.16E+02 7.00E+00 1.35E+02 9.67E+01 8.80E+01 PASS 1.16E+02 7.68E+00 1.37E+02 9.52E+01 8.80E+01 PASS 1.16E+02 7.53E+00 1.37E+02 9.57E+01 8.80E+01 PASS 1.16E+02 7.13E+00 1.36E+02 9.65E+01 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 354 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.172. Plot of Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 355 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.172. Raw data for Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.11E+02 1.18E+02 1.19E+02 1.14E+02 1.16E+02 1.13E+02 1.10E+02 1.18E+02 1.09E+02 1.10E+02 1.16E+02 1.10E+02 24 Hr Anneal 60 1.11E+02 1.18E+02 1.18E+02 1.14E+02 1.16E+02 1.13E+02 1.10E+02 1.19E+02 1.09E+02 1.10E+02 1.16E+02 1.10E+02 168 Hr Anneal 70 1.11E+02 1.18E+02 1.19E+02 1.14E+02 1.16E+02 1.13E+02 1.10E+02 1.18E+02 1.09E+02 1.10E+02 1.16E+02 1.10E+02 0 1.11E+02 1.17E+02 1.18E+02 1.14E+02 1.16E+02 1.13E+02 1.10E+02 1.18E+02 1.08E+02 1.10E+02 1.16E+02 1.10E+02 10 1.11E+02 1.18E+02 1.18E+02 1.13E+02 1.16E+02 1.13E+02 1.10E+02 1.18E+02 1.08E+02 1.10E+02 1.16E+02 1.10E+02 Total Dose (krad(Si)) 20 30 1.11E+02 1.11E+02 1.17E+02 1.18E+02 1.18E+02 1.18E+02 1.13E+02 1.13E+02 1.16E+02 1.16E+02 1.13E+02 1.13E+02 1.10E+02 1.10E+02 1.18E+02 1.18E+02 1.08E+02 1.08E+02 1.10E+02 1.10E+02 1.16E+02 1.16E+02 1.10E+02 1.10E+02 1.15E+02 2.94E+00 1.23E+02 1.07E+02 1.15E+02 3.04E+00 1.24E+02 1.07E+02 1.15E+02 2.91E+00 1.23E+02 1.07E+02 1.15E+02 3.14E+00 1.24E+02 1.07E+02 1.15E+02 3.01E+00 1.24E+02 1.07E+02 1.15E+02 2.99E+00 1.24E+02 1.07E+02 1.15E+02 3.06E+00 1.24E+02 1.07E+02 1.12E+02 3.96E+00 1.23E+02 1.01E+02 8.80E+01 PASS 1.12E+02 3.96E+00 1.23E+02 1.01E+02 8.80E+01 PASS 1.12E+02 3.96E+00 1.23E+02 1.01E+02 8.80E+01 PASS 1.12E+02 3.91E+00 1.23E+02 1.01E+02 8.80E+01 PASS 1.12E+02 3.94E+00 1.23E+02 1.01E+02 8.80E+01 PASS 1.12E+02 4.02E+00 1.23E+02 1.01E+02 8.80E+01 PASS 1.12E+02 3.91E+00 1.23E+02 1.01E+02 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 356 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.173. Plot of Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 357 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.173. Raw data for Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.11E+02 1.43E+02 1.12E+02 1.11E+02 1.12E+02 1.24E+02 1.06E+02 1.17E+02 1.08E+02 1.14E+02 1.15E+02 1.16E+02 24 Hr Anneal 60 1.11E+02 1.43E+02 1.12E+02 1.11E+02 1.12E+02 1.24E+02 1.06E+02 1.17E+02 1.08E+02 1.14E+02 1.15E+02 1.16E+02 168 Hr Anneal 70 1.11E+02 1.43E+02 1.12E+02 1.11E+02 1.12E+02 1.24E+02 1.06E+02 1.17E+02 1.08E+02 1.14E+02 1.15E+02 1.16E+02 0 1.11E+02 1.40E+02 1.11E+02 1.11E+02 1.12E+02 1.24E+02 1.06E+02 1.17E+02 1.08E+02 1.14E+02 1.15E+02 1.16E+02 10 1.11E+02 1.37E+02 1.11E+02 1.11E+02 1.12E+02 1.25E+02 1.06E+02 1.17E+02 1.08E+02 1.14E+02 1.15E+02 1.16E+02 Total Dose (krad(Si)) 20 30 1.11E+02 1.11E+02 1.43E+02 1.42E+02 1.11E+02 1.12E+02 1.11E+02 1.11E+02 1.12E+02 1.12E+02 1.26E+02 1.24E+02 1.06E+02 1.06E+02 1.17E+02 1.17E+02 1.08E+02 1.08E+02 1.14E+02 1.14E+02 1.15E+02 1.15E+02 1.16E+02 1.16E+02 1.17E+02 1.30E+01 1.53E+02 8.16E+01 1.17E+02 1.13E+01 1.48E+02 8.55E+01 1.18E+02 1.43E+01 1.57E+02 7.87E+01 1.18E+02 1.36E+01 1.55E+02 8.03E+01 1.18E+02 1.42E+01 1.57E+02 7.91E+01 1.18E+02 1.40E+01 1.56E+02 7.96E+01 1.18E+02 1.40E+01 1.56E+02 7.95E+01 1.14E+02 7.20E+00 1.33E+02 9.39E+01 8.80E+01 PASS 1.14E+02 7.63E+00 1.35E+02 9.30E+01 8.80E+01 PASS 1.14E+02 7.82E+00 1.35E+02 9.26E+01 8.80E+01 PASS 1.14E+02 7.23E+00 1.33E+02 9.38E+01 8.80E+01 PASS 1.14E+02 7.20E+00 1.34E+02 9.41E+01 8.80E+01 PASS 1.14E+02 7.41E+00 1.34E+02 9.36E+01 8.80E+01 PASS 1.14E+02 7.19E+00 1.33E+02 9.41E+01 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 358 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.174. Plot of Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 359 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.174. Raw data for Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 50 1.13E+02 1.18E+02 1.15E+02 1.14E+02 1.13E+02 1.16E+02 1.26E+02 1.17E+02 1.12E+02 1.21E+02 1.06E+02 1.14E+02 24 Hr Anneal 60 1.13E+02 1.18E+02 1.15E+02 1.14E+02 1.13E+02 1.16E+02 1.26E+02 1.17E+02 1.12E+02 1.21E+02 1.06E+02 1.14E+02 168 Hr Anneal 70 1.13E+02 1.18E+02 1.15E+02 1.14E+02 1.13E+02 1.16E+02 1.27E+02 1.18E+02 1.12E+02 1.21E+02 1.06E+02 1.14E+02 0 1.13E+02 1.18E+02 1.15E+02 1.14E+02 1.13E+02 1.16E+02 1.26E+02 1.17E+02 1.12E+02 1.20E+02 1.06E+02 1.14E+02 10 1.13E+02 1.18E+02 1.15E+02 1.14E+02 1.13E+02 1.16E+02 1.26E+02 1.17E+02 1.12E+02 1.20E+02 1.06E+02 1.14E+02 Total Dose (krad(Si)) 20 30 1.13E+02 1.13E+02 1.18E+02 1.18E+02 1.15E+02 1.15E+02 1.14E+02 1.14E+02 1.13E+02 1.13E+02 1.16E+02 1.16E+02 1.27E+02 1.26E+02 1.17E+02 1.17E+02 1.12E+02 1.12E+02 1.21E+02 1.20E+02 1.06E+02 1.06E+02 1.14E+02 1.14E+02 1.14E+02 2.10E+00 1.20E+02 1.09E+02 1.14E+02 2.13E+00 1.20E+02 1.09E+02 1.15E+02 2.11E+00 1.20E+02 1.09E+02 1.14E+02 2.13E+00 1.20E+02 1.09E+02 1.15E+02 2.25E+00 1.21E+02 1.09E+02 1.15E+02 2.28E+00 1.21E+02 1.08E+02 1.15E+02 2.15E+00 1.21E+02 1.09E+02 1.18E+02 5.40E+00 1.33E+02 1.04E+02 8.80E+01 PASS 1.18E+02 5.43E+00 1.33E+02 1.04E+02 8.80E+01 PASS 1.19E+02 5.45E+00 1.34E+02 1.04E+02 8.80E+01 PASS 1.18E+02 5.43E+00 1.33E+02 1.03E+02 8.80E+01 PASS 1.18E+02 5.14E+00 1.33E+02 1.04E+02 8.80E+01 PASS 1.18E+02 5.32E+00 1.33E+02 1.04E+02 8.80E+01 PASS 1.19E+02 5.44E+00 1.34E+02 1.04E+02 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 360 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.175. Plot of PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 361 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.175. Raw data for PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V Device 557 563 564 567 569 570 571 572 573 574 584 585 0 1.14E+02 1.17E+02 1.33E+02 1.23E+02 1.20E+02 1.17E+02 1.41E+02 1.17E+02 1.35E+02 1.34E+02 1.12E+02 1.35E+02 Biased Statistics Average Biased 1.21E+02 Std Dev Biased 7.04E+00 Ps90%/90% (+KTL) Biased 1.41E+02 Ps90%/90% (-KTL) Biased 1.02E+02 Un-Biased Statistics Average Un-Biased 1.29E+02 Std Dev Un-Biased 1.12E+01 Ps90%/90% (+KTL) Un-Biased 1.59E+02 Ps90%/90% (-KTL) Un-Biased 9.79E+01 Specification MIN 8.20E+01 Status PASS 50 1.14E+02 1.17E+02 1.31E+02 1.23E+02 1.21E+02 1.17E+02 1.44E+02 1.16E+02 1.33E+02 1.38E+02 1.12E+02 1.33E+02 24 Hr Anneal 60 1.14E+02 1.18E+02 1.31E+02 1.24E+02 1.20E+02 1.17E+02 1.53E+02 1.17E+02 1.33E+02 1.36E+02 1.12E+02 1.34E+02 168 Hr Anneal 70 1.14E+02 1.18E+02 1.30E+02 1.23E+02 1.20E+02 1.17E+02 1.43E+02 1.16E+02 1.34E+02 1.36E+02 1.12E+02 1.36E+02 1.21E+02 6.06E+00 1.38E+02 1.04E+02 1.21E+02 6.49E+00 1.39E+02 1.04E+02 1.21E+02 6.26E+00 1.38E+02 1.04E+02 1.21E+02 5.94E+00 1.37E+02 1.05E+02 1.29E+02 1.15E+01 1.61E+02 9.76E+01 8.20E+01 PASS 1.30E+02 1.26E+01 1.64E+02 9.51E+01 8.20E+01 PASS 1.31E+02 1.49E+01 1.72E+02 9.02E+01 8.20E+01 PASS 1.29E+02 1.20E+01 1.62E+02 9.63E+01 8.20E+01 PASS 10 1.14E+02 1.18E+02 1.32E+02 1.23E+02 1.20E+02 1.17E+02 1.39E+02 1.17E+02 1.34E+02 1.38E+02 1.12E+02 1.35E+02 Total Dose (krad(Si)) 20 30 1.14E+02 1.14E+02 1.18E+02 1.18E+02 1.30E+02 1.30E+02 1.24E+02 1.23E+02 1.20E+02 1.20E+02 1.17E+02 1.17E+02 1.42E+02 1.42E+02 1.16E+02 1.17E+02 1.33E+02 1.34E+02 1.37E+02 1.36E+02 1.12E+02 1.12E+02 1.34E+02 1.34E+02 1.21E+02 6.75E+00 1.40E+02 1.03E+02 1.21E+02 5.97E+00 1.37E+02 1.05E+02 1.29E+02 1.12E+01 1.60E+02 9.82E+01 8.20E+01 PASS 1.29E+02 1.17E+01 1.61E+02 9.66E+01 8.20E+01 PASS An ISO 9001:2008 and DSCC Certified Company 362 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.176. Plot of PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 363 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.176. Raw data for PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V Device 557 563 564 567 569 570 571 572 573 574 584 585 0 1.40E+02 1.18E+02 1.17E+02 1.24E+02 1.21E+02 1.16E+02 1.14E+02 1.31E+02 1.34E+02 1.06E+02 1.34E+02 1.15E+02 Biased Statistics Average Biased 1.24E+02 Std Dev Biased 9.36E+00 Ps90%/90% (+KTL) Biased 1.49E+02 Ps90%/90% (-KTL) Biased 9.81E+01 Un-Biased Statistics Average Un-Biased 1.20E+02 Std Dev Un-Biased 1.19E+01 Ps90%/90% (+KTL) Un-Biased 1.53E+02 Ps90%/90% (-KTL) Un-Biased 8.71E+01 Specification MIN 8.20E+01 Status PASS 50 1.60E+02 1.18E+02 1.17E+02 1.24E+02 1.22E+02 1.16E+02 1.14E+02 1.32E+02 1.36E+02 1.06E+02 1.34E+02 1.15E+02 24 Hr Anneal 60 1.45E+02 1.18E+02 1.17E+02 1.24E+02 1.22E+02 1.16E+02 1.14E+02 1.33E+02 1.34E+02 1.06E+02 1.34E+02 1.15E+02 168 Hr Anneal 70 1.58E+02 1.18E+02 1.17E+02 1.24E+02 1.22E+02 1.16E+02 1.14E+02 1.33E+02 1.36E+02 1.06E+02 1.33E+02 1.15E+02 1.28E+02 1.78E+01 1.77E+02 7.94E+01 1.28E+02 1.81E+01 1.78E+02 7.86E+01 1.25E+02 1.15E+01 1.57E+02 9.39E+01 1.28E+02 1.72E+01 1.75E+02 8.06E+01 1.21E+02 1.28E+01 1.56E+02 8.55E+01 8.20E+01 PASS 1.21E+02 1.28E+01 1.56E+02 8.56E+01 8.20E+01 PASS 1.20E+02 1.24E+01 1.54E+02 8.64E+01 8.20E+01 PASS 1.21E+02 1.31E+01 1.57E+02 8.51E+01 8.20E+01 PASS 10 1.45E+02 1.19E+02 1.17E+02 1.25E+02 1.21E+02 1.15E+02 1.14E+02 1.32E+02 1.36E+02 1.06E+02 1.33E+02 1.15E+02 Total Dose (krad(Si)) 20 30 1.48E+02 1.59E+02 1.18E+02 1.18E+02 1.17E+02 1.17E+02 1.25E+02 1.25E+02 1.22E+02 1.22E+02 1.15E+02 1.16E+02 1.14E+02 1.14E+02 1.33E+02 1.34E+02 1.34E+02 1.34E+02 1.06E+02 1.06E+02 1.32E+02 1.32E+02 1.15E+02 1.15E+02 1.25E+02 1.16E+01 1.57E+02 9.35E+01 1.26E+02 1.26E+01 1.60E+02 9.11E+01 1.20E+02 1.27E+01 1.55E+02 8.55E+01 8.20E+01 PASS 1.20E+02 1.26E+01 1.55E+02 8.59E+01 8.20E+01 PASS An ISO 9001:2008 and DSCC Certified Company 364 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased +Short-Circuit Current2 1 5V (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.177. Plot of +Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 365 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.177. Raw data for +Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 1 5V (A) @ VS=+5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -2.65E-02 -2.43E-02 -2.37E-02 -2.38E-02 -2.47E-02 -2.44E-02 -2.46E-02 -2.45E-02 -2.39E-02 -2.52E-02 -2.61E-02 -2.62E-02 Total Dose (krad(Si)) 20 30 -2.62E-02 -2.61E-02 -2.40E-02 -2.40E-02 -2.34E-02 -2.33E-02 -2.35E-02 -2.34E-02 -2.43E-02 -2.42E-02 -2.42E-02 -2.41E-02 -2.45E-02 -2.43E-02 -2.43E-02 -2.42E-02 -2.37E-02 -2.36E-02 -2.50E-02 -2.49E-02 -2.61E-02 -2.61E-02 -2.62E-02 -2.62E-02 10 -2.64E-02 -2.42E-02 -2.35E-02 -2.36E-02 -2.45E-02 -2.44E-02 -2.46E-02 -2.44E-02 -2.38E-02 -2.51E-02 -2.61E-02 -2.62E-02 50 -2.58E-02 -2.37E-02 -2.31E-02 -2.32E-02 -2.40E-02 -2.39E-02 -2.41E-02 -2.39E-02 -2.34E-02 -2.46E-02 -2.61E-02 -2.62E-02 24 Hr Anneal 60 -2.58E-02 -2.37E-02 -2.31E-02 -2.32E-02 -2.40E-02 -2.39E-02 -2.41E-02 -2.39E-02 -2.34E-02 -2.46E-02 -2.61E-02 -2.62E-02 168 Hr Anneal 70 -2.60E-02 -2.39E-02 -2.33E-02 -2.34E-02 -2.42E-02 -2.41E-02 -2.42E-02 -2.41E-02 -2.35E-02 -2.48E-02 -2.61E-02 -2.62E-02 -2.46E-02 -2.44E-02 -2.43E-02 -2.42E-02 -2.40E-02 -2.40E-02 -2.42E-02 1.13E-03 1.16E-03 1.15E-03 1.14E-03 1.10E-03 1.10E-03 1.11E-03 -2.15E-02 -2.12E-02 -2.11E-02 -2.11E-02 -2.10E-02 -2.10E-02 -2.11E-02 -2.77E-02 -2.76E-02 -2.74E-02 -2.73E-02 -2.70E-02 -2.70E-02 -2.72E-02 -2.45E-02 4.57E-04 -2.32E-02 -2.58E-02 -1.25E-02 PASS -2.45E-02 4.64E-04 -2.32E-02 -2.57E-02 -8.00E-03 PASS -2.43E-02 4.56E-04 -2.31E-02 -2.56E-02 -8.00E-03 PASS -2.42E-02 4.53E-04 -2.30E-02 -2.55E-02 -8.00E-03 PASS -2.40E-02 4.41E-04 -2.27E-02 -2.52E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 366 -2.40E-02 4.40E-04 -2.28E-02 -2.52E-02 -8.00E-03 PASS -2.41E-02 4.48E-04 -2.29E-02 -2.54E-02 -8.00E-03 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased +Short-Circuit Current2 2 5V (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.178. Plot of +Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 367 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.178. Raw data for +Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 2 5V (A) @ VS=+5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -2.80E-02 -2.38E-02 -2.38E-02 -2.35E-02 -2.51E-02 -2.44E-02 -2.51E-02 -2.62E-02 -2.38E-02 -2.63E-02 -2.44E-02 -2.43E-02 Total Dose (krad(Si)) 20 30 -2.77E-02 -2.75E-02 -2.35E-02 -2.35E-02 -2.35E-02 -2.34E-02 -2.32E-02 -2.31E-02 -2.47E-02 -2.46E-02 -2.42E-02 -2.41E-02 -2.49E-02 -2.48E-02 -2.60E-02 -2.58E-02 -2.37E-02 -2.36E-02 -2.61E-02 -2.60E-02 -2.44E-02 -2.44E-02 -2.43E-02 -2.43E-02 10 -2.78E-02 -2.36E-02 -2.36E-02 -2.33E-02 -2.49E-02 -2.44E-02 -2.50E-02 -2.61E-02 -2.38E-02 -2.62E-02 -2.44E-02 -2.43E-02 50 -2.72E-02 -2.32E-02 -2.32E-02 -2.29E-02 -2.44E-02 -2.39E-02 -2.45E-02 -2.55E-02 -2.33E-02 -2.56E-02 -2.44E-02 -2.42E-02 24 Hr Anneal 60 -2.72E-02 -2.32E-02 -2.32E-02 -2.29E-02 -2.44E-02 -2.39E-02 -2.45E-02 -2.55E-02 -2.33E-02 -2.56E-02 -2.43E-02 -2.42E-02 168 Hr Anneal 70 -2.75E-02 -2.34E-02 -2.34E-02 -2.31E-02 -2.46E-02 -2.40E-02 -2.47E-02 -2.57E-02 -2.35E-02 -2.58E-02 -2.44E-02 -2.43E-02 -2.48E-02 -2.47E-02 -2.45E-02 -2.44E-02 -2.42E-02 -2.42E-02 -2.44E-02 1.86E-03 1.86E-03 1.86E-03 1.83E-03 1.79E-03 1.79E-03 1.80E-03 -1.97E-02 -1.95E-02 -1.94E-02 -1.94E-02 -1.93E-02 -1.93E-02 -1.95E-02 -2.99E-02 -2.98E-02 -2.96E-02 -2.94E-02 -2.91E-02 -2.91E-02 -2.93E-02 -2.52E-02 1.06E-03 -2.22E-02 -2.81E-02 -1.25E-02 PASS -2.51E-02 1.07E-03 -2.22E-02 -2.80E-02 -8.00E-03 PASS -2.50E-02 1.06E-03 -2.21E-02 -2.79E-02 -8.00E-03 PASS -2.49E-02 1.05E-03 -2.20E-02 -2.77E-02 -8.00E-03 PASS -2.45E-02 1.03E-03 -2.17E-02 -2.74E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 368 -2.45E-02 1.03E-03 -2.17E-02 -2.74E-02 -8.00E-03 PASS -2.47E-02 1.03E-03 -2.19E-02 -2.76E-02 -8.00E-03 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased +Short-Circuit Current2 3 5V (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.179. Plot of +Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 369 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.179. Raw data for +Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 3 5V (A) @ VS=+5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -2.79E-02 -2.36E-02 -2.40E-02 -2.36E-02 -2.52E-02 -2.43E-02 -2.52E-02 -2.62E-02 -2.38E-02 -2.64E-02 -2.42E-02 -2.43E-02 Total Dose (krad(Si)) 20 30 -2.76E-02 -2.75E-02 -2.33E-02 -2.32E-02 -2.36E-02 -2.35E-02 -2.32E-02 -2.32E-02 -2.48E-02 -2.47E-02 -2.42E-02 -2.41E-02 -2.51E-02 -2.49E-02 -2.60E-02 -2.59E-02 -2.36E-02 -2.35E-02 -2.63E-02 -2.61E-02 -2.42E-02 -2.43E-02 -2.43E-02 -2.43E-02 10 -2.78E-02 -2.34E-02 -2.38E-02 -2.34E-02 -2.50E-02 -2.43E-02 -2.52E-02 -2.61E-02 -2.37E-02 -2.64E-02 -2.42E-02 -2.43E-02 50 -2.71E-02 -2.30E-02 -2.34E-02 -2.30E-02 -2.45E-02 -2.38E-02 -2.46E-02 -2.56E-02 -2.32E-02 -2.58E-02 -2.42E-02 -2.43E-02 24 Hr Anneal 60 -2.71E-02 -2.30E-02 -2.33E-02 -2.30E-02 -2.45E-02 -2.38E-02 -2.46E-02 -2.56E-02 -2.32E-02 -2.58E-02 -2.42E-02 -2.42E-02 168 Hr Anneal 70 -2.74E-02 -2.32E-02 -2.35E-02 -2.32E-02 -2.47E-02 -2.40E-02 -2.48E-02 -2.58E-02 -2.34E-02 -2.60E-02 -2.42E-02 -2.43E-02 -2.48E-02 -2.47E-02 -2.45E-02 -2.44E-02 -2.42E-02 -2.42E-02 -2.44E-02 1.83E-03 1.85E-03 1.83E-03 1.81E-03 1.76E-03 1.76E-03 1.78E-03 -1.98E-02 -1.96E-02 -1.95E-02 -1.95E-02 -1.94E-02 -1.94E-02 -1.95E-02 -2.98E-02 -2.97E-02 -2.95E-02 -2.94E-02 -2.90E-02 -2.90E-02 -2.93E-02 -2.52E-02 1.16E-03 -2.20E-02 -2.84E-02 -1.25E-02 PASS -2.51E-02 1.16E-03 -2.20E-02 -2.83E-02 -8.00E-03 PASS -2.50E-02 1.15E-03 -2.19E-02 -2.82E-02 -8.00E-03 PASS -2.49E-02 1.14E-03 -2.18E-02 -2.80E-02 -8.00E-03 PASS -2.46E-02 1.12E-03 -2.15E-02 -2.77E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 370 -2.46E-02 1.12E-03 -2.15E-02 -2.76E-02 -8.00E-03 PASS -2.48E-02 1.13E-03 -2.17E-02 -2.79E-02 -8.00E-03 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Ps90%/90% (+KTL) Biased +Short-Circuit Current2 4 5V (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.180. Plot of +Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 371 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.180. Raw data for +Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 4 5V (A) @ VS=+5V Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 -2.63E-02 -2.43E-02 -2.36E-02 -2.38E-02 -2.46E-02 -2.44E-02 -2.46E-02 -2.44E-02 -2.38E-02 -2.52E-02 -2.60E-02 -2.62E-02 Total Dose (krad(Si)) 20 30 -2.61E-02 -2.60E-02 -2.40E-02 -2.39E-02 -2.33E-02 -2.32E-02 -2.35E-02 -2.34E-02 -2.42E-02 -2.42E-02 -2.43E-02 -2.42E-02 -2.44E-02 -2.43E-02 -2.43E-02 -2.41E-02 -2.37E-02 -2.36E-02 -2.50E-02 -2.49E-02 -2.61E-02 -2.61E-02 -2.62E-02 -2.62E-02 10 -2.62E-02 -2.42E-02 -2.34E-02 -2.36E-02 -2.44E-02 -2.44E-02 -2.45E-02 -2.44E-02 -2.38E-02 -2.51E-02 -2.61E-02 -2.62E-02 50 -2.57E-02 -2.37E-02 -2.30E-02 -2.32E-02 -2.40E-02 -2.39E-02 -2.40E-02 -2.39E-02 -2.33E-02 -2.46E-02 -2.60E-02 -2.62E-02 24 Hr Anneal 60 -2.56E-02 -2.37E-02 -2.30E-02 -2.32E-02 -2.40E-02 -2.39E-02 -2.40E-02 -2.39E-02 -2.33E-02 -2.46E-02 -2.60E-02 -2.62E-02 168 Hr Anneal 70 -2.59E-02 -2.39E-02 -2.32E-02 -2.34E-02 -2.42E-02 -2.41E-02 -2.42E-02 -2.40E-02 -2.35E-02 -2.48E-02 -2.60E-02 -2.62E-02 -2.45E-02 -2.44E-02 -2.42E-02 -2.41E-02 -2.39E-02 -2.39E-02 -2.41E-02 1.09E-03 1.11E-03 1.11E-03 1.09E-03 1.05E-03 1.05E-03 1.07E-03 -2.15E-02 -2.13E-02 -2.12E-02 -2.11E-02 -2.10E-02 -2.10E-02 -2.12E-02 -2.75E-02 -2.74E-02 -2.73E-02 -2.71E-02 -2.68E-02 -2.68E-02 -2.70E-02 -2.45E-02 4.86E-04 -2.32E-02 -2.58E-02 -1.25E-02 PASS -2.44E-02 4.86E-04 -2.31E-02 -2.58E-02 -8.00E-03 PASS -2.43E-02 4.86E-04 -2.30E-02 -2.57E-02 -8.00E-03 PASS -2.42E-02 4.82E-04 -2.29E-02 -2.55E-02 -8.00E-03 PASS -2.39E-02 4.71E-04 -2.26E-02 -2.52E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 372 -2.39E-02 4.67E-04 -2.26E-02 -2.52E-02 -8.00E-03 PASS -2.41E-02 4.75E-04 -2.28E-02 -2.54E-02 -8.00E-03 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased -Short-Circuit Current2 1 5V (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.181. Plot of -Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 373 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.181. Raw data for -Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr -Short-Circuit Current2 1 5V (A) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V Device 0 10 20 30 50 60 70 557 5.10E-02 5.11E-02 5.10E-02 5.09E-02 5.12E-02 5.13E-02 5.11E-02 563 4.89E-02 4.90E-02 4.88E-02 4.87E-02 4.89E-02 4.91E-02 4.88E-02 564 4.79E-02 4.77E-02 4.77E-02 4.75E-02 4.77E-02 4.81E-02 4.77E-02 567 4.78E-02 4.75E-02 4.75E-02 4.74E-02 4.77E-02 4.78E-02 4.77E-02 569 4.89E-02 4.87E-02 4.87E-02 4.86E-02 4.89E-02 4.91E-02 4.88E-02 570 4.90E-02 4.89E-02 4.88E-02 4.87E-02 4.92E-02 4.91E-02 4.90E-02 571 4.89E-02 4.90E-02 4.88E-02 4.87E-02 4.90E-02 4.90E-02 4.90E-02 572 4.79E-02 4.82E-02 4.78E-02 4.78E-02 4.82E-02 4.83E-02 4.81E-02 573 4.81E-02 4.83E-02 4.80E-02 4.79E-02 4.83E-02 4.83E-02 4.82E-02 574 4.98E-02 4.98E-02 4.95E-02 4.94E-02 4.97E-02 4.99E-02 4.96E-02 584 5.10E-02 5.09E-02 5.08E-02 5.07E-02 5.12E-02 5.12E-02 5.10E-02 585 5.04E-02 5.02E-02 5.00E-02 5.02E-02 5.06E-02 5.08E-02 5.04E-02 Biased Statistics Average Biased 4.89E-02 4.88E-02 4.87E-02 4.86E-02 4.89E-02 4.91E-02 4.88E-02 Std Dev Biased 1.28E-03 1.43E-03 1.39E-03 1.38E-03 1.42E-03 1.39E-03 1.38E-03 Ps90%/90% (+KTL) Biased 5.24E-02 5.27E-02 5.25E-02 5.24E-02 5.28E-02 5.29E-02 5.26E-02 Ps90%/90% (-KTL) Biased 4.54E-02 4.49E-02 4.49E-02 4.48E-02 4.50E-02 4.53E-02 4.50E-02 Un-Biased Statistics Average Un-Biased 4.87E-02 4.88E-02 4.86E-02 4.85E-02 4.89E-02 4.89E-02 4.88E-02 Std Dev Un-Biased 7.33E-04 6.39E-04 6.76E-04 6.44E-04 6.59E-04 6.68E-04 6.54E-04 Ps90%/90% (+KTL) Un-Biased 5.08E-02 5.06E-02 5.04E-02 5.03E-02 5.07E-02 5.07E-02 5.06E-02 Ps90%/90% (-KTL) Un-Biased 4.67E-02 4.71E-02 4.67E-02 4.67E-02 4.71E-02 4.71E-02 4.70E-02 Specification MIN 1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 374 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased -Short-Circuit Current2 2 5V (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.182. Plot of -Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 375 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.182. Raw data for -Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr -Short-Circuit Current2 2 5V (A) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V Device 0 10 20 30 50 60 70 557 5.16E-02 5.16E-02 5.16E-02 5.15E-02 5.18E-02 5.19E-02 5.17E-02 563 4.70E-02 4.71E-02 4.69E-02 4.68E-02 4.70E-02 4.72E-02 4.69E-02 564 4.73E-02 4.71E-02 4.70E-02 4.68E-02 4.71E-02 4.74E-02 4.71E-02 567 4.73E-02 4.71E-02 4.70E-02 4.70E-02 4.73E-02 4.74E-02 4.73E-02 569 4.88E-02 4.85E-02 4.86E-02 4.85E-02 4.89E-02 4.89E-02 4.87E-02 570 4.80E-02 4.79E-02 4.78E-02 4.77E-02 4.82E-02 4.82E-02 4.80E-02 571 4.90E-02 4.91E-02 4.89E-02 4.88E-02 4.91E-02 4.92E-02 4.92E-02 572 4.99E-02 5.01E-02 4.99E-02 4.98E-02 5.01E-02 5.02E-02 5.01E-02 573 4.77E-02 4.79E-02 4.77E-02 4.75E-02 4.78E-02 4.79E-02 4.78E-02 574 5.04E-02 5.04E-02 5.01E-02 5.00E-02 5.04E-02 5.05E-02 5.03E-02 584 4.79E-02 4.78E-02 4.78E-02 4.77E-02 4.82E-02 4.82E-02 4.79E-02 585 4.82E-02 4.79E-02 4.78E-02 4.79E-02 4.83E-02 4.85E-02 4.82E-02 Biased Statistics Average Biased 4.84E-02 4.83E-02 4.82E-02 4.81E-02 4.84E-02 4.86E-02 4.83E-02 Std Dev Biased 1.93E-03 1.98E-03 2.00E-03 2.00E-03 2.04E-03 2.00E-03 2.00E-03 Ps90%/90% (+KTL) Biased 5.37E-02 5.37E-02 5.37E-02 5.36E-02 5.40E-02 5.41E-02 5.38E-02 Ps90%/90% (-KTL) Biased 4.31E-02 4.29E-02 4.27E-02 4.26E-02 4.28E-02 4.31E-02 4.28E-02 Un-Biased Statistics Average Un-Biased 4.90E-02 4.91E-02 4.89E-02 4.88E-02 4.91E-02 4.92E-02 4.91E-02 Std Dev Un-Biased 1.17E-03 1.15E-03 1.14E-03 1.13E-03 1.13E-03 1.17E-03 1.15E-03 Ps90%/90% (+KTL) Un-Biased 5.22E-02 5.22E-02 5.20E-02 5.19E-02 5.22E-02 5.24E-02 5.22E-02 Ps90%/90% (-KTL) Un-Biased 4.58E-02 4.59E-02 4.58E-02 4.56E-02 4.60E-02 4.60E-02 4.59E-02 Specification MIN 1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 376 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased -Short-Circuit Current2 3 5V (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.183. Plot of -Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 377 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.183. Raw data for -Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr -Short-Circuit Current2 3 5V (A) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V Device 0 10 20 30 50 60 70 557 5.23E-02 5.24E-02 5.23E-02 5.22E-02 5.26E-02 5.27E-02 5.24E-02 563 4.77E-02 4.78E-02 4.76E-02 4.74E-02 4.77E-02 4.79E-02 4.76E-02 564 4.79E-02 4.77E-02 4.77E-02 4.75E-02 4.77E-02 4.81E-02 4.77E-02 567 4.80E-02 4.77E-02 4.77E-02 4.77E-02 4.80E-02 4.81E-02 4.79E-02 569 4.94E-02 4.91E-02 4.93E-02 4.91E-02 4.95E-02 4.96E-02 4.93E-02 570 4.88E-02 4.88E-02 4.87E-02 4.85E-02 4.90E-02 4.90E-02 4.89E-02 571 5.00E-02 5.01E-02 4.99E-02 4.98E-02 5.01E-02 5.01E-02 5.00E-02 572 5.07E-02 5.10E-02 5.06E-02 5.06E-02 5.09E-02 5.11E-02 5.08E-02 573 4.84E-02 4.86E-02 4.83E-02 4.82E-02 4.86E-02 4.86E-02 4.84E-02 574 5.12E-02 5.12E-02 5.10E-02 5.09E-02 5.12E-02 5.14E-02 5.11E-02 584 4.87E-02 4.85E-02 4.85E-02 4.84E-02 4.89E-02 4.89E-02 4.87E-02 585 4.89E-02 4.87E-02 4.85E-02 4.87E-02 4.90E-02 4.93E-02 4.89E-02 Biased Statistics Average Biased 4.90E-02 4.90E-02 4.89E-02 4.88E-02 4.91E-02 4.93E-02 4.90E-02 Std Dev Biased 1.94E-03 2.03E-03 2.03E-03 2.02E-03 2.07E-03 2.02E-03 2.03E-03 Ps90%/90% (+KTL) Biased 5.44E-02 5.45E-02 5.45E-02 5.43E-02 5.48E-02 5.48E-02 5.46E-02 Ps90%/90% (-KTL) Biased 4.37E-02 4.34E-02 4.33E-02 4.32E-02 4.34E-02 4.37E-02 4.34E-02 Un-Biased Statistics Average Un-Biased 4.98E-02 4.99E-02 4.97E-02 4.96E-02 5.00E-02 5.00E-02 4.99E-02 Std Dev Un-Biased 1.20E-03 1.22E-03 1.18E-03 1.19E-03 1.16E-03 1.22E-03 1.18E-03 Ps90%/90% (+KTL) Un-Biased 5.31E-02 5.33E-02 5.29E-02 5.28E-02 5.31E-02 5.34E-02 5.31E-02 Ps90%/90% (-KTL) Un-Biased 4.65E-02 4.66E-02 4.65E-02 4.63E-02 4.68E-02 4.67E-02 4.66E-02 Specification MIN 1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 378 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Ps90%/90% (-KTL) Biased -Short-Circuit Current2 4 5V (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.184. Plot of -Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 379 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.184. Raw data for -Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). 24 Hr 168 Hr -Short-Circuit Current2 4 5V (A) Total Dose (krad(Si)) Anneal Anneal @ VS=+5V Device 0 10 20 30 50 60 70 557 5.05E-02 5.06E-02 5.05E-02 5.04E-02 5.07E-02 5.08E-02 5.06E-02 563 4.84E-02 4.85E-02 4.83E-02 4.82E-02 4.84E-02 4.87E-02 4.83E-02 564 4.75E-02 4.72E-02 4.72E-02 4.70E-02 4.72E-02 4.75E-02 4.73E-02 567 4.71E-02 4.69E-02 4.68E-02 4.68E-02 4.71E-02 4.72E-02 4.71E-02 569 4.84E-02 4.82E-02 4.82E-02 4.81E-02 4.84E-02 4.85E-02 4.83E-02 570 4.84E-02 4.83E-02 4.83E-02 4.81E-02 4.86E-02 4.85E-02 4.84E-02 571 4.83E-02 4.84E-02 4.82E-02 4.81E-02 4.84E-02 4.85E-02 4.84E-02 572 4.76E-02 4.78E-02 4.75E-02 4.74E-02 4.77E-02 4.79E-02 4.77E-02 573 4.76E-02 4.78E-02 4.75E-02 4.74E-02 4.77E-02 4.78E-02 4.77E-02 574 4.92E-02 4.91E-02 4.89E-02 4.88E-02 4.92E-02 4.93E-02 4.91E-02 584 5.03E-02 5.01E-02 5.01E-02 4.99E-02 5.05E-02 5.05E-02 5.02E-02 585 4.96E-02 4.94E-02 4.93E-02 4.94E-02 4.98E-02 5.01E-02 4.96E-02 Biased Statistics Average Biased 4.84E-02 4.83E-02 4.82E-02 4.81E-02 4.84E-02 4.86E-02 4.83E-02 Std Dev Biased 1.32E-03 1.46E-03 1.42E-03 1.42E-03 1.44E-03 1.42E-03 1.41E-03 Ps90%/90% (+KTL) Biased 5.20E-02 5.23E-02 5.21E-02 5.20E-02 5.23E-02 5.25E-02 5.21E-02 Ps90%/90% (-KTL) Biased 4.48E-02 4.43E-02 4.43E-02 4.42E-02 4.44E-02 4.47E-02 4.44E-02 Un-Biased Statistics Average Un-Biased 4.82E-02 4.83E-02 4.81E-02 4.79E-02 4.83E-02 4.84E-02 4.83E-02 Std Dev Un-Biased 6.52E-04 5.48E-04 5.97E-04 5.77E-04 5.97E-04 6.25E-04 6.07E-04 Ps90%/90% (+KTL) Un-Biased 5.00E-02 4.98E-02 4.97E-02 4.95E-02 5.00E-02 5.01E-02 4.99E-02 Ps90%/90% (-KTL) Un-Biased 4.64E-02 4.68E-02 4.65E-02 4.64E-02 4.67E-02 4.67E-02 4.66E-02 Specification MIN 1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 Status PASS PASS PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 380 ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.80E+01 Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz 1.60E+01 1.40E+01 1.20E+01 1.00E+01 8.00E+00 6.00E+00 4.00E+00 2.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.185. Plot of Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 381 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.185. Raw data for Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.61E+01 1.64E+01 1.66E+01 1.67E+01 1.65E+01 1.66E+01 1.61E+01 1.65E+01 1.63E+01 1.63E+01 1.57E+01 1.62E+01 10 1.61E+01 1.64E+01 1.66E+01 1.67E+01 1.65E+01 1.66E+01 1.61E+01 1.66E+01 1.63E+01 1.63E+01 1.57E+01 1.62E+01 Total Dose (krad(Si)) 20 30 1.61E+01 1.61E+01 1.64E+01 1.64E+01 1.66E+01 1.65E+01 1.67E+01 1.66E+01 1.64E+01 1.64E+01 1.66E+01 1.66E+01 1.61E+01 1.60E+01 1.65E+01 1.65E+01 1.63E+01 1.63E+01 1.63E+01 1.63E+01 1.57E+01 1.57E+01 1.62E+01 1.62E+01 50 1.61E+01 1.63E+01 1.65E+01 1.66E+01 1.64E+01 1.65E+01 1.60E+01 1.65E+01 1.62E+01 1.62E+01 1.57E+01 1.62E+01 24 Hr Anneal 60 1.61E+01 1.63E+01 1.65E+01 1.66E+01 1.64E+01 1.65E+01 1.60E+01 1.64E+01 1.62E+01 1.63E+01 1.57E+01 1.62E+01 168 Hr Anneal 70 1.61E+01 1.63E+01 1.65E+01 1.66E+01 1.64E+01 1.65E+01 1.60E+01 1.64E+01 1.62E+01 1.63E+01 1.57E+01 1.62E+01 1.65E+01 1.65E+01 1.64E+01 1.64E+01 1.64E+01 1.64E+01 1.64E+01 2.26E-01 2.16E-01 2.15E-01 1.89E-01 2.05E-01 2.03E-01 2.14E-01 1.71E+01 1.71E+01 1.70E+01 1.69E+01 1.69E+01 1.69E+01 1.70E+01 1.58E+01 1.59E+01 1.58E+01 1.59E+01 1.58E+01 1.58E+01 1.58E+01 1.64E+01 2.00E-01 1.69E+01 1.58E+01 6.80E+00 PASS 1.64E+01 2.06E-01 1.69E+01 1.58E+01 4.50E+00 PASS 1.64E+01 1.98E-01 1.69E+01 1.58E+01 4.50E+00 PASS 1.63E+01 2.08E-01 1.69E+01 1.57E+01 4.50E+00 PASS 1.63E+01 1.95E-01 1.68E+01 1.57E+01 4.50E+00 PASS An ISO 9001:2008 and DSCC Certified Company 382 1.63E+01 1.86E-01 1.68E+01 1.58E+01 4.50E+00 PASS 1.63E+01 1.97E-01 1.68E+01 1.57E+01 4.50E+00 PASS ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.80E+01 Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz 1.60E+01 1.40E+01 1.20E+01 1.00E+01 8.00E+00 6.00E+00 4.00E+00 2.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.186. Plot of Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 383 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.186. Raw data for Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.59E+01 1.68E+01 1.65E+01 1.64E+01 1.61E+01 1.64E+01 1.61E+01 1.62E+01 1.59E+01 1.61E+01 1.66E+01 1.65E+01 10 1.59E+01 1.68E+01 1.64E+01 1.63E+01 1.61E+01 1.64E+01 1.62E+01 1.62E+01 1.59E+01 1.61E+01 1.66E+01 1.65E+01 Total Dose (krad(Si)) 20 30 1.59E+01 1.58E+01 1.68E+01 1.68E+01 1.64E+01 1.64E+01 1.63E+01 1.63E+01 1.61E+01 1.60E+01 1.64E+01 1.63E+01 1.61E+01 1.61E+01 1.62E+01 1.61E+01 1.58E+01 1.58E+01 1.61E+01 1.61E+01 1.66E+01 1.66E+01 1.65E+01 1.65E+01 50 1.58E+01 1.67E+01 1.63E+01 1.63E+01 1.60E+01 1.63E+01 1.61E+01 1.61E+01 1.58E+01 1.60E+01 1.65E+01 1.65E+01 24 Hr Anneal 60 1.58E+01 1.67E+01 1.64E+01 1.63E+01 1.60E+01 1.63E+01 1.61E+01 1.61E+01 1.57E+01 1.60E+01 1.66E+01 1.66E+01 168 Hr Anneal 70 1.58E+01 1.67E+01 1.64E+01 1.62E+01 1.60E+01 1.63E+01 1.60E+01 1.61E+01 1.58E+01 1.60E+01 1.66E+01 1.65E+01 1.63E+01 1.63E+01 1.63E+01 1.63E+01 1.62E+01 1.62E+01 1.62E+01 3.59E-01 3.71E-01 3.48E-01 3.50E-01 3.50E-01 3.52E-01 3.46E-01 1.73E+01 1.73E+01 1.72E+01 1.72E+01 1.72E+01 1.72E+01 1.72E+01 1.54E+01 1.53E+01 1.53E+01 1.53E+01 1.53E+01 1.53E+01 1.53E+01 1.61E+01 1.69E-01 1.66E+01 1.57E+01 6.80E+00 PASS 1.61E+01 1.85E-01 1.67E+01 1.56E+01 4.50E+00 PASS 1.61E+01 1.98E-01 1.67E+01 1.56E+01 4.50E+00 PASS 1.61E+01 1.89E-01 1.66E+01 1.56E+01 4.50E+00 PASS 1.61E+01 1.99E-01 1.66E+01 1.55E+01 4.50E+00 PASS An ISO 9001:2008 and DSCC Certified Company 384 1.61E+01 2.11E-01 1.66E+01 1.55E+01 4.50E+00 PASS 1.61E+01 1.93E-01 1.66E+01 1.55E+01 4.50E+00 PASS ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.80E+01 Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz 1.60E+01 1.40E+01 1.20E+01 1.00E+01 8.00E+00 6.00E+00 4.00E+00 2.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.187. Plot of Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 385 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.187. Raw data for Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.58E+01 1.68E+01 1.65E+01 1.64E+01 1.60E+01 1.65E+01 1.61E+01 1.62E+01 1.58E+01 1.62E+01 1.64E+01 1.65E+01 10 1.58E+01 1.68E+01 1.65E+01 1.63E+01 1.59E+01 1.65E+01 1.61E+01 1.62E+01 1.58E+01 1.62E+01 1.64E+01 1.65E+01 Total Dose (krad(Si)) 20 30 1.58E+01 1.58E+01 1.67E+01 1.67E+01 1.64E+01 1.64E+01 1.63E+01 1.63E+01 1.59E+01 1.59E+01 1.64E+01 1.64E+01 1.61E+01 1.60E+01 1.61E+01 1.61E+01 1.58E+01 1.58E+01 1.61E+01 1.61E+01 1.64E+01 1.64E+01 1.65E+01 1.65E+01 50 1.58E+01 1.67E+01 1.64E+01 1.63E+01 1.58E+01 1.64E+01 1.60E+01 1.61E+01 1.57E+01 1.61E+01 1.64E+01 1.65E+01 24 Hr Anneal 60 1.58E+01 1.67E+01 1.64E+01 1.63E+01 1.59E+01 1.64E+01 1.60E+01 1.61E+01 1.58E+01 1.61E+01 1.64E+01 1.65E+01 168 Hr Anneal 70 1.58E+01 1.67E+01 1.64E+01 1.63E+01 1.59E+01 1.64E+01 1.60E+01 1.61E+01 1.58E+01 1.61E+01 1.64E+01 1.65E+01 1.63E+01 1.63E+01 1.62E+01 1.62E+01 1.62E+01 1.62E+01 1.62E+01 3.84E-01 3.83E-01 3.75E-01 3.74E-01 3.69E-01 3.85E-01 3.78E-01 1.73E+01 1.73E+01 1.73E+01 1.72E+01 1.72E+01 1.72E+01 1.72E+01 1.52E+01 1.52E+01 1.52E+01 1.52E+01 1.52E+01 1.51E+01 1.51E+01 1.61E+01 2.34E-01 1.68E+01 1.55E+01 6.80E+00 PASS 1.61E+01 2.22E-01 1.68E+01 1.55E+01 4.50E+00 PASS 1.61E+01 2.23E-01 1.67E+01 1.55E+01 4.50E+00 PASS 1.61E+01 2.42E-01 1.67E+01 1.54E+01 4.50E+00 PASS 1.61E+01 2.53E-01 1.67E+01 1.54E+01 4.50E+00 PASS An ISO 9001:2008 and DSCC Certified Company 386 1.61E+01 2.25E-01 1.67E+01 1.55E+01 4.50E+00 PASS 1.61E+01 2.17E-01 1.66E+01 1.55E+01 4.50E+00 PASS ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.80E+01 Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz 1.60E+01 1.40E+01 1.20E+01 1.00E+01 8.00E+00 6.00E+00 4.00E+00 2.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.188. Plot of Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 387 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.188. Raw data for Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.60E+01 1.65E+01 1.65E+01 1.67E+01 1.65E+01 1.65E+01 1.62E+01 1.64E+01 1.64E+01 1.64E+01 1.57E+01 1.62E+01 10 1.60E+01 1.64E+01 1.65E+01 1.66E+01 1.65E+01 1.65E+01 1.62E+01 1.64E+01 1.64E+01 1.63E+01 1.57E+01 1.62E+01 Total Dose (krad(Si)) 20 30 1.60E+01 1.60E+01 1.64E+01 1.64E+01 1.64E+01 1.64E+01 1.66E+01 1.66E+01 1.65E+01 1.65E+01 1.65E+01 1.65E+01 1.61E+01 1.61E+01 1.64E+01 1.63E+01 1.64E+01 1.63E+01 1.63E+01 1.63E+01 1.57E+01 1.57E+01 1.61E+01 1.61E+01 50 1.59E+01 1.63E+01 1.64E+01 1.66E+01 1.64E+01 1.65E+01 1.61E+01 1.63E+01 1.63E+01 1.63E+01 1.57E+01 1.62E+01 24 Hr Anneal 60 1.60E+01 1.63E+01 1.64E+01 1.65E+01 1.64E+01 1.64E+01 1.61E+01 1.63E+01 1.63E+01 1.62E+01 1.57E+01 1.62E+01 168 Hr Anneal 70 1.60E+01 1.63E+01 1.64E+01 1.66E+01 1.64E+01 1.64E+01 1.61E+01 1.63E+01 1.63E+01 1.63E+01 1.57E+01 1.62E+01 1.64E+01 1.64E+01 1.64E+01 1.64E+01 1.63E+01 1.63E+01 1.63E+01 2.37E-01 2.29E-01 2.25E-01 2.27E-01 2.27E-01 2.11E-01 2.27E-01 1.71E+01 1.70E+01 1.70E+01 1.70E+01 1.69E+01 1.69E+01 1.69E+01 1.58E+01 1.58E+01 1.58E+01 1.57E+01 1.57E+01 1.57E+01 1.57E+01 1.64E+01 1.16E-01 1.67E+01 1.61E+01 6.80E+00 PASS 1.64E+01 1.18E-01 1.67E+01 1.60E+01 4.50E+00 PASS 1.63E+01 1.36E-01 1.67E+01 1.60E+01 4.50E+00 PASS 1.63E+01 1.25E-01 1.66E+01 1.60E+01 4.50E+00 PASS 1.63E+01 1.45E-01 1.67E+01 1.59E+01 4.50E+00 PASS An ISO 9001:2008 and DSCC Certified Company 388 1.63E+01 1.16E-01 1.66E+01 1.60E+01 4.50E+00 PASS 1.63E+01 1.12E-01 1.66E+01 1.60E+01 4.50E+00 PASS +Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 8.00E+00 7.00E+00 6.00E+00 5.00E+00 4.00E+00 3.00E+00 2.00E+00 1.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.189. Plot of +Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 389 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.189. Raw data for +Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 6.83E+00 6.91E+00 6.99E+00 7.08E+00 6.94E+00 6.99E+00 6.78E+00 7.04E+00 6.87E+00 6.87E+00 6.62E+00 6.83E+00 10 6.79E+00 6.89E+00 6.99E+00 7.15E+00 6.95E+00 6.98E+00 6.76E+00 6.97E+00 6.84E+00 6.89E+00 6.65E+00 6.82E+00 Total Dose (krad(Si)) 20 30 6.80E+00 6.82E+00 6.89E+00 6.86E+00 6.98E+00 6.97E+00 7.05E+00 7.06E+00 6.91E+00 6.95E+00 6.98E+00 6.95E+00 6.72E+00 6.75E+00 6.97E+00 6.96E+00 6.82E+00 6.82E+00 6.86E+00 6.85E+00 6.63E+00 6.65E+00 6.85E+00 6.82E+00 50 6.76E+00 6.86E+00 6.93E+00 7.00E+00 6.87E+00 6.91E+00 6.67E+00 6.94E+00 6.76E+00 6.82E+00 6.63E+00 6.82E+00 24 Hr Anneal 60 6.80E+00 6.81E+00 6.88E+00 7.02E+00 6.89E+00 6.92E+00 6.71E+00 6.92E+00 6.81E+00 6.81E+00 6.64E+00 6.80E+00 168 Hr Anneal 70 6.77E+00 6.87E+00 6.92E+00 7.02E+00 6.89E+00 6.92E+00 6.70E+00 6.97E+00 6.80E+00 6.81E+00 6.65E+00 6.80E+00 6.95E+00 6.95E+00 6.93E+00 6.93E+00 6.88E+00 6.88E+00 6.89E+00 9.30E-02 1.33E-01 9.45E-02 9.47E-02 8.91E-02 8.80E-02 9.02E-02 7.21E+00 7.32E+00 7.19E+00 7.19E+00 7.13E+00 7.12E+00 7.14E+00 6.69E+00 6.59E+00 6.67E+00 6.67E+00 6.64E+00 6.64E+00 6.65E+00 6.91E+00 1.04E-01 7.20E+00 6.62E+00 3.50E+00 PASS 6.89E+00 9.20E-02 7.14E+00 6.64E+00 3.00E+00 PASS 6.87E+00 1.09E-01 7.17E+00 6.57E+00 3.00E+00 PASS 6.87E+00 8.91E-02 7.11E+00 6.62E+00 3.00E+00 PASS 6.82E+00 1.10E-01 7.12E+00 6.52E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 390 6.83E+00 8.85E-02 7.08E+00 6.59E+00 3.00E+00 PASS 6.84E+00 1.07E-01 7.13E+00 6.55E+00 3.00E+00 PASS +Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 8.00E+00 7.00E+00 6.00E+00 5.00E+00 4.00E+00 3.00E+00 2.00E+00 1.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.190. Plot of +Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 391 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.190. Raw data for +Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 6.96E+00 7.59E+00 7.16E+00 7.09E+00 7.03E+00 7.09E+00 6.97E+00 7.02E+00 6.87E+00 7.01E+00 7.30E+00 7.26E+00 10 6.96E+00 7.53E+00 7.17E+00 7.14E+00 7.03E+00 7.08E+00 6.97E+00 7.03E+00 6.83E+00 6.96E+00 7.35E+00 7.24E+00 Total Dose (krad(Si)) 20 30 6.98E+00 6.97E+00 7.55E+00 7.54E+00 7.09E+00 7.11E+00 7.09E+00 7.14E+00 7.00E+00 6.99E+00 7.02E+00 7.02E+00 6.96E+00 6.96E+00 7.03E+00 7.01E+00 6.80E+00 6.81E+00 6.97E+00 6.97E+00 7.36E+00 7.30E+00 7.29E+00 7.26E+00 50 6.91E+00 7.45E+00 7.08E+00 7.10E+00 6.95E+00 7.00E+00 6.92E+00 6.98E+00 6.79E+00 6.90E+00 7.31E+00 7.26E+00 24 Hr Anneal 60 6.90E+00 7.50E+00 7.07E+00 7.05E+00 6.93E+00 6.98E+00 6.90E+00 7.00E+00 6.81E+00 6.95E+00 7.30E+00 7.22E+00 168 Hr Anneal 70 6.91E+00 7.46E+00 7.08E+00 7.10E+00 6.95E+00 7.00E+00 6.93E+00 6.96E+00 6.79E+00 6.95E+00 7.34E+00 7.26E+00 7.17E+00 7.17E+00 7.14E+00 7.15E+00 7.10E+00 7.09E+00 7.10E+00 2.48E-01 2.20E-01 2.34E-01 2.30E-01 2.13E-01 2.41E-01 2.17E-01 7.85E+00 7.77E+00 7.78E+00 7.78E+00 7.68E+00 7.75E+00 7.70E+00 6.49E+00 6.56E+00 6.50E+00 6.52E+00 6.51E+00 6.43E+00 6.50E+00 6.99E+00 8.07E-02 7.21E+00 6.77E+00 3.50E+00 PASS 6.97E+00 9.40E-02 7.23E+00 6.72E+00 3.00E+00 PASS 6.96E+00 9.24E-02 7.21E+00 6.70E+00 3.00E+00 PASS 6.95E+00 8.44E-02 7.19E+00 6.72E+00 3.00E+00 PASS 6.92E+00 8.26E-02 7.14E+00 6.69E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 392 6.93E+00 7.60E-02 7.14E+00 6.72E+00 3.00E+00 PASS 6.93E+00 8.02E-02 7.15E+00 6.71E+00 3.00E+00 PASS +Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 8.00E+00 7.00E+00 6.00E+00 5.00E+00 4.00E+00 3.00E+00 2.00E+00 1.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.191. Plot of +Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 393 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.191. Raw data for +Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 6.70E+00 7.18E+00 7.06E+00 7.00E+00 6.72E+00 7.02E+00 6.82E+00 6.80E+00 6.67E+00 6.83E+00 6.97E+00 6.94E+00 10 6.69E+00 7.09E+00 7.03E+00 6.98E+00 6.73E+00 7.00E+00 6.78E+00 6.82E+00 6.64E+00 6.82E+00 6.97E+00 6.93E+00 Total Dose (krad(Si)) 20 30 6.65E+00 6.70E+00 7.15E+00 7.11E+00 7.05E+00 7.02E+00 6.98E+00 6.95E+00 6.74E+00 6.72E+00 6.97E+00 7.00E+00 6.75E+00 6.77E+00 6.81E+00 6.77E+00 6.61E+00 6.59E+00 6.83E+00 6.84E+00 7.01E+00 6.97E+00 6.99E+00 6.95E+00 50 6.67E+00 7.08E+00 6.99E+00 6.91E+00 6.71E+00 6.91E+00 6.71E+00 6.75E+00 6.58E+00 6.76E+00 6.94E+00 6.99E+00 24 Hr Anneal 60 6.65E+00 7.06E+00 6.99E+00 6.90E+00 6.68E+00 6.92E+00 6.69E+00 6.75E+00 6.57E+00 6.78E+00 6.92E+00 6.93E+00 168 Hr Anneal 70 6.66E+00 7.09E+00 7.00E+00 6.92E+00 6.70E+00 6.96E+00 6.69E+00 6.76E+00 6.60E+00 6.79E+00 6.97E+00 6.96E+00 6.93E+00 6.90E+00 6.91E+00 6.90E+00 6.87E+00 6.86E+00 6.87E+00 2.13E-01 1.82E-01 2.11E-01 1.83E-01 1.77E-01 1.84E-01 1.88E-01 7.52E+00 7.40E+00 7.49E+00 7.40E+00 7.36E+00 7.36E+00 7.39E+00 6.35E+00 6.41E+00 6.33E+00 6.40E+00 6.39E+00 6.35E+00 6.36E+00 6.83E+00 1.25E-01 7.17E+00 6.48E+00 3.50E+00 PASS 6.81E+00 1.29E-01 7.16E+00 6.46E+00 3.00E+00 PASS 6.79E+00 1.31E-01 7.15E+00 6.44E+00 3.00E+00 PASS 6.79E+00 1.48E-01 7.20E+00 6.39E+00 3.00E+00 PASS 6.74E+00 1.18E-01 7.07E+00 6.42E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 394 6.74E+00 1.28E-01 7.09E+00 6.39E+00 3.00E+00 PASS 6.76E+00 1.34E-01 7.13E+00 6.39E+00 3.00E+00 PASS +Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 8.00E+00 7.00E+00 6.00E+00 5.00E+00 4.00E+00 3.00E+00 2.00E+00 1.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.192. Plot of +Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 395 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.192. Raw data for +Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 6.91E+00 7.12E+00 7.24E+00 7.39E+00 7.25E+00 7.25E+00 6.91E+00 7.10E+00 7.12E+00 7.05E+00 6.72E+00 6.98E+00 10 6.92E+00 7.09E+00 7.15E+00 7.36E+00 7.23E+00 7.23E+00 6.91E+00 7.12E+00 7.10E+00 7.04E+00 6.78E+00 6.99E+00 Total Dose (krad(Si)) 20 30 6.91E+00 6.90E+00 7.04E+00 7.10E+00 7.13E+00 7.14E+00 7.30E+00 7.31E+00 7.22E+00 7.17E+00 7.15E+00 7.16E+00 6.92E+00 6.90E+00 7.12E+00 7.10E+00 7.09E+00 7.09E+00 7.11E+00 7.05E+00 6.74E+00 6.75E+00 6.91E+00 6.95E+00 50 6.88E+00 7.08E+00 7.09E+00 7.22E+00 7.12E+00 7.09E+00 6.86E+00 7.07E+00 7.07E+00 6.98E+00 6.76E+00 6.93E+00 24 Hr Anneal 60 6.88E+00 7.08E+00 7.07E+00 7.25E+00 7.12E+00 7.10E+00 6.84E+00 7.04E+00 7.02E+00 7.01E+00 6.73E+00 6.95E+00 168 Hr Anneal 70 6.87E+00 7.05E+00 7.11E+00 7.23E+00 7.16E+00 7.12E+00 6.87E+00 7.08E+00 7.03E+00 7.03E+00 6.74E+00 6.95E+00 7.18E+00 7.15E+00 7.12E+00 7.12E+00 7.08E+00 7.08E+00 7.08E+00 1.80E-01 1.64E-01 1.52E-01 1.48E-01 1.24E-01 1.33E-01 1.37E-01 7.67E+00 7.60E+00 7.54E+00 7.53E+00 7.42E+00 7.44E+00 7.46E+00 6.69E+00 6.70E+00 6.70E+00 6.72E+00 6.74E+00 6.72E+00 6.71E+00 7.09E+00 1.23E-01 7.42E+00 6.75E+00 3.50E+00 PASS 7.08E+00 1.17E-01 7.40E+00 6.76E+00 3.00E+00 PASS 7.08E+00 9.09E-02 7.33E+00 6.83E+00 3.00E+00 PASS 7.06E+00 9.77E-02 7.33E+00 6.79E+00 3.00E+00 PASS 7.01E+00 9.61E-02 7.28E+00 6.75E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 396 7.00E+00 9.71E-02 7.27E+00 6.74E+00 3.00E+00 PASS 7.03E+00 9.50E-02 7.29E+00 6.77E+00 3.00E+00 PASS -Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 8.00E+00 7.00E+00 6.00E+00 5.00E+00 4.00E+00 3.00E+00 2.00E+00 1.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.193. Plot of -Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 397 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.193. Raw data for -Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 6.47E+00 6.64E+00 6.78E+00 6.78E+00 6.67E+00 6.74E+00 6.44E+00 6.77E+00 6.53E+00 6.55E+00 6.19E+00 6.51E+00 10 6.44E+00 6.60E+00 6.75E+00 6.79E+00 6.64E+00 6.72E+00 6.44E+00 6.72E+00 6.50E+00 6.57E+00 6.17E+00 6.51E+00 Total Dose (krad(Si)) 20 30 6.43E+00 6.44E+00 6.55E+00 6.58E+00 6.75E+00 6.71E+00 6.80E+00 6.78E+00 6.64E+00 6.62E+00 6.72E+00 6.72E+00 6.43E+00 6.39E+00 6.71E+00 6.70E+00 6.50E+00 6.50E+00 6.53E+00 6.54E+00 6.18E+00 6.17E+00 6.57E+00 6.50E+00 50 6.40E+00 6.53E+00 6.72E+00 6.75E+00 6.59E+00 6.64E+00 6.33E+00 6.69E+00 6.43E+00 6.50E+00 6.20E+00 6.52E+00 24 Hr Anneal 60 6.39E+00 6.51E+00 6.63E+00 6.73E+00 6.55E+00 6.65E+00 6.35E+00 6.64E+00 6.44E+00 6.47E+00 6.19E+00 6.50E+00 168 Hr Anneal 70 6.38E+00 6.54E+00 6.70E+00 6.76E+00 6.57E+00 6.66E+00 6.35E+00 6.66E+00 6.47E+00 6.50E+00 6.21E+00 6.50E+00 6.67E+00 6.64E+00 6.63E+00 6.63E+00 6.60E+00 6.56E+00 6.59E+00 1.28E-01 1.38E-01 1.50E-01 1.30E-01 1.43E-01 1.28E-01 1.48E-01 7.02E+00 7.02E+00 7.04E+00 6.98E+00 6.99E+00 6.91E+00 7.00E+00 6.32E+00 6.27E+00 6.22E+00 6.27E+00 6.21E+00 6.21E+00 6.18E+00 6.61E+00 1.43E-01 7.00E+00 6.22E+00 3.50E+00 PASS 6.59E+00 1.27E-01 6.94E+00 6.24E+00 3.00E+00 PASS 6.58E+00 1.30E-01 6.94E+00 6.22E+00 3.00E+00 PASS 6.57E+00 1.39E-01 6.95E+00 6.19E+00 3.00E+00 PASS 6.52E+00 1.48E-01 6.92E+00 6.11E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 398 6.51E+00 1.31E-01 6.87E+00 6.15E+00 3.00E+00 PASS 6.53E+00 1.33E-01 6.89E+00 6.16E+00 3.00E+00 PASS -Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 8.00E+00 7.00E+00 6.00E+00 5.00E+00 4.00E+00 3.00E+00 2.00E+00 1.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.194. Plot of -Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 399 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.194. Raw data for -Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 6.66E+00 7.13E+00 6.91E+00 6.83E+00 6.70E+00 6.84E+00 6.69E+00 6.77E+00 6.46E+00 6.70E+00 6.97E+00 6.93E+00 10 6.62E+00 7.09E+00 6.86E+00 6.83E+00 6.68E+00 6.82E+00 6.65E+00 6.75E+00 6.43E+00 6.71E+00 6.99E+00 6.95E+00 Total Dose (krad(Si)) 20 30 6.61E+00 6.59E+00 7.11E+00 7.12E+00 6.85E+00 6.84E+00 6.81E+00 6.80E+00 6.64E+00 6.64E+00 6.81E+00 6.81E+00 6.62E+00 6.67E+00 6.73E+00 6.75E+00 6.45E+00 6.44E+00 6.68E+00 6.67E+00 6.99E+00 6.95E+00 6.98E+00 6.96E+00 50 6.54E+00 7.05E+00 6.79E+00 6.73E+00 6.58E+00 6.76E+00 6.57E+00 6.68E+00 6.38E+00 6.65E+00 6.95E+00 6.92E+00 24 Hr Anneal 60 6.54E+00 7.07E+00 6.81E+00 6.73E+00 6.62E+00 6.72E+00 6.58E+00 6.65E+00 6.36E+00 6.62E+00 6.96E+00 6.85E+00 168 Hr Anneal 70 6.57E+00 7.09E+00 6.80E+00 6.76E+00 6.61E+00 6.75E+00 6.62E+00 6.68E+00 6.41E+00 6.67E+00 6.97E+00 6.92E+00 6.85E+00 6.82E+00 6.80E+00 6.80E+00 6.74E+00 6.75E+00 6.77E+00 1.88E-01 1.83E-01 2.00E-01 2.08E-01 2.03E-01 2.05E-01 2.05E-01 7.36E+00 7.32E+00 7.35E+00 7.37E+00 7.29E+00 7.31E+00 7.33E+00 6.33E+00 6.31E+00 6.26E+00 6.23E+00 6.18E+00 6.19E+00 6.20E+00 6.69E+00 1.43E-01 7.08E+00 6.30E+00 3.50E+00 PASS 6.67E+00 1.49E-01 7.08E+00 6.26E+00 3.00E+00 PASS 6.66E+00 1.36E-01 7.03E+00 6.29E+00 3.00E+00 PASS 6.67E+00 1.40E-01 7.05E+00 6.28E+00 3.00E+00 PASS 6.61E+00 1.44E-01 7.00E+00 6.21E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 400 6.59E+00 1.36E-01 6.96E+00 6.21E+00 3.00E+00 PASS 6.63E+00 1.29E-01 6.98E+00 6.27E+00 3.00E+00 PASS -Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 7.00E+00 6.00E+00 5.00E+00 4.00E+00 3.00E+00 2.00E+00 1.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.195. Plot of -Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 401 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.195. Raw data for -Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 6.44E+00 6.88E+00 6.77E+00 6.64E+00 6.38E+00 6.66E+00 6.53E+00 6.59E+00 6.28E+00 6.55E+00 6.68E+00 6.65E+00 10 6.43E+00 6.84E+00 6.75E+00 6.62E+00 6.36E+00 6.64E+00 6.52E+00 6.55E+00 6.26E+00 6.52E+00 6.69E+00 6.70E+00 Total Dose (krad(Si)) 20 30 6.42E+00 6.41E+00 6.81E+00 6.79E+00 6.72E+00 6.71E+00 6.61E+00 6.58E+00 6.35E+00 6.35E+00 6.62E+00 6.63E+00 6.49E+00 6.47E+00 6.59E+00 6.55E+00 6.28E+00 6.26E+00 6.49E+00 6.49E+00 6.66E+00 6.70E+00 6.73E+00 6.70E+00 50 6.35E+00 6.80E+00 6.66E+00 6.54E+00 6.28E+00 6.57E+00 6.42E+00 6.51E+00 6.20E+00 6.47E+00 6.69E+00 6.69E+00 24 Hr Anneal 60 6.37E+00 6.76E+00 6.64E+00 6.49E+00 6.27E+00 6.58E+00 6.43E+00 6.52E+00 6.19E+00 6.43E+00 6.65E+00 6.67E+00 168 Hr Anneal 70 6.39E+00 6.80E+00 6.68E+00 6.55E+00 6.28E+00 6.57E+00 6.42E+00 6.51E+00 6.19E+00 6.47E+00 6.65E+00 6.70E+00 6.62E+00 6.60E+00 6.58E+00 6.57E+00 6.53E+00 6.51E+00 6.54E+00 2.12E-01 2.04E-01 1.95E-01 1.88E-01 2.15E-01 1.98E-01 2.11E-01 7.20E+00 7.16E+00 7.12E+00 7.08E+00 7.12E+00 7.05E+00 7.12E+00 6.04E+00 6.04E+00 6.05E+00 6.05E+00 5.94E+00 5.96E+00 5.96E+00 6.52E+00 1.44E-01 6.92E+00 6.13E+00 3.50E+00 PASS 6.50E+00 1.42E-01 6.89E+00 6.11E+00 3.00E+00 PASS 6.49E+00 1.33E-01 6.86E+00 6.13E+00 3.00E+00 PASS 6.48E+00 1.38E-01 6.86E+00 6.10E+00 3.00E+00 PASS 6.43E+00 1.42E-01 6.82E+00 6.04E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 402 6.43E+00 1.48E-01 6.84E+00 6.02E+00 3.00E+00 PASS 6.43E+00 1.46E-01 6.83E+00 6.03E+00 3.00E+00 PASS -Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ ELDRS Report 12-640 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 8.00E+00 7.00E+00 6.00E+00 5.00E+00 4.00E+00 3.00E+00 2.00E+00 1.00E+00 0.00E+00 0 10 20 30 40 50 24 Hr 60 Anneal 168 Hr 70 Anneal Total Dose (krad(Si)) Figure 5.196. Plot of -Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 403 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.196. Raw data for -Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ Device 557 563 564 567 569 570 571 572 573 574 584 585 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 6.66E+00 6.91E+00 7.00E+00 7.11E+00 6.99E+00 6.95E+00 6.74E+00 6.90E+00 6.80E+00 6.82E+00 6.52E+00 6.79E+00 10 6.65E+00 6.87E+00 6.96E+00 7.08E+00 6.96E+00 6.95E+00 6.70E+00 6.92E+00 6.81E+00 6.78E+00 6.52E+00 6.81E+00 Total Dose (krad(Si)) 20 30 6.61E+00 6.65E+00 6.87E+00 6.87E+00 6.90E+00 6.93E+00 7.06E+00 7.06E+00 6.91E+00 6.92E+00 6.93E+00 6.94E+00 6.71E+00 6.74E+00 6.87E+00 6.89E+00 6.78E+00 6.78E+00 6.81E+00 6.75E+00 6.53E+00 6.53E+00 6.81E+00 6.81E+00 50 6.56E+00 6.81E+00 6.88E+00 6.98E+00 6.88E+00 6.83E+00 6.68E+00 6.82E+00 6.73E+00 6.73E+00 6.50E+00 6.81E+00 24 Hr Anneal 60 6.57E+00 6.81E+00 6.85E+00 6.93E+00 6.86E+00 6.83E+00 6.64E+00 6.80E+00 6.69E+00 6.74E+00 6.51E+00 6.77E+00 168 Hr Anneal 70 6.59E+00 6.83E+00 6.91E+00 6.99E+00 6.90E+00 6.88E+00 6.67E+00 6.83E+00 6.74E+00 6.73E+00 6.52E+00 6.81E+00 6.93E+00 6.90E+00 6.87E+00 6.89E+00 6.82E+00 6.80E+00 6.84E+00 1.69E-01 1.60E-01 1.63E-01 1.49E-01 1.58E-01 1.38E-01 1.53E-01 7.40E+00 7.34E+00 7.32E+00 7.30E+00 7.26E+00 7.18E+00 7.26E+00 6.47E+00 6.46E+00 6.42E+00 6.48E+00 6.39E+00 6.43E+00 6.42E+00 6.84E+00 8.32E-02 7.07E+00 6.61E+00 3.50E+00 PASS 6.83E+00 1.03E-01 7.11E+00 6.55E+00 3.00E+00 PASS 6.82E+00 8.43E-02 7.05E+00 6.59E+00 3.00E+00 PASS 6.82E+00 8.97E-02 7.07E+00 6.57E+00 3.00E+00 PASS 6.76E+00 6.46E-02 6.94E+00 6.58E+00 3.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 404 6.74E+00 7.78E-02 6.95E+00 6.53E+00 3.00E+00 PASS 6.77E+00 8.40E-02 7.00E+00 6.54E+00 3.00E+00 PASS ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 6.0. Summary / Conclusions The low dose rate testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The low dose rate source is a GB-150 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead. During the irradiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from approximately 1mrad(Si)/s to a maximum of approximately 50rad(Si)/s, determined by the distance from the source. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the low dose rate test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. Based on this criterion the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp (from the lot date code identified on the first page of this test report) PASSED the enhanced low dose rate sensitivity test to the maximum tested dose level of 50krad(Si) with all parameters remaining within their datasheet specifications. Further, the data in this report can be analyzed along with the high dose rate report titled "Total Ionizing Dose (TID) Radiation Testing of the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp for Linear Technology" to demonstrate that these parts do not exhibit ELDRS as defined in the current test method. An ISO 9001:2008 and DSCC Certified Company 405 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix A: Photograph of Packing Label and a Sample Unit-Under-Test to Show Part Traceability An ISO 9001:2008 and DSCC Certified Company 406 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix B: Radiation Bias Connections and Absolute Maximum Ratings ELDRS Radiation Biased Conditions: Extracted from Linear Technology RH1499M datasheet, ID No 66-10-1499. Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Function OUT A -INPUT A +INPUT A V+ +INPUT B -INPUT B OUT B OUT C -INPUT C +INPUT C V+INPUT D -INPUT D OUT D Connection / Bias To Pin 2 via 5kΩ & 40pF, in Parallel To Pin 1 via 5kΩ & 40pF, in Parallel To 8V via 5kΩ Resistor To +15V using 0.1µF Decoupling To 8V via 5kΩ Resistor To Pin 7 via 5kΩ & 40pF, in Parallel To Pin 6 via 5kΩ & 40pF, in Parallel To Pin 9 via 5kΩ & 40pF, in Parallel To Pin 8 via 5kΩ & 40pF, in Parallel To 8V via 5kΩ Resistor To -15V using 0.1µF Decoupling To 8V via 10kΩ Resistor To Pin 14 via 5kΩ & 40pF, in Parallel To Pin 13 via 5kΩ & 40pF, in Parallel Figure B.1. Irradiation bias circuit. This figure was extracted from Linear Technology RH1499M datasheet, ID No 66-10-1499. An ISO 9001:2008 and DSCC Certified Company 407 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ELDRS Radiation Unbiased Conditions: Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Function OUT A -INPUT A +INPUT A V+ +INPUT B -INPUT B OUT B OUT C -INPUT C +INPUT C V+INPUT D -INPUT D OUT D Connection / Bias GND GND GND GND GND GND GND GND GND GND GND GND GND GND Figure B.2. W package drawing (for reference only). This figure was extracted from Linear Technology RH1499M datasheet, ID No 66-10-1499. Absolute Maximum Ratings: Parameter Total Supply Voltage (V+ to V-) Input Current Output Short-Circuit Duration Max Rating 36V ±10mA Continuous An ISO 9001:2008 and DSCC Certified Company 408 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix C: Electrical Test Parameters and Conditions The expected ranges of values as well as the measurement conditions are taken from Linear Technology RH1499M datasheet. All electrical tests for this device are performed on one of Aeroflex RAD's LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that provides parameter measurements for a variety of digital, analog and mixed signal products including voltage regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System achieves accuracy and sensitivity through the use of software self-calibration and an internal relay matrix with separate family boards and custom personality adapter boards. The tester uses this relay matrix to connect the required test circuits, select the appropriate voltage / current sources and establish the needed measurement loops for all the tests performed. The measured parameters and test conditions are shown in Table C.1. A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020 for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90 KTL statistics were applied to the measured standard deviation to generate the final measurement range. This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020 mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the measurement resolution is limited by the internal DACs, which results in a measured standard deviation of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC. Note that the testing and statistics used in this document are based on an “analysis of variables” technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p. 91 for a discussion of statistical treatments). Not all measured parameters are well suited to this approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify these parameters using an “attributes” approach. An ISO 9001:2008 and DSCC Certified Company 409 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.1. Measured parameters and test conditions for the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp. Parameter Symbol Test Conditions +Supply Current 15V (A) +ICC15 VS=+/-15V -Supply Current 15V (A) -IEE15 VS=+/-15V Input Offset Voltage1 15V (V) VOS1_14 15V VS=+/-15V, VCM=0V Input Offset Current1 15V (A) IOS1_14 15V VS=+/-15V, VCM=0V +Input Bias Current BIAS1 15V (A) +IBIAS1_14 15V VS=+/-15V, VCM=0V -Input Bias Current BIAS1 15V (A) -IBIAS1_14 15V VS=+/-15V, VCM=0V Input Offset Voltage2 15V (V) VOS2_14 15V VS=+/-15V, VCM=15V Input Offset Current2 15V (A) IOS2_14 15V VS=+/-15V, VCM=15V +Input Bias Current BIAS2 15V (A) +IBIAS2_14 15V VS=+/-15V, VCM=15V -Input Bias Current BIAS2 15V (A) -IBIAS2_14 15V VS=+/-15V, VCM=15V Input Offset Voltage3 15V (V) VOS3_14 15V VS=+/-15V, VCM=-15V Input Offset Current3 15V (A) IOS3_14 15V VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 15V (A) +IBIAS3_14 15V VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 15V (A) -IBIAS3_14 15V VS=+/-15V, VCM=-15V Output Voltage Swing High1 15V (V) +VOUT1_14 15V VS=+/-15V IL=0mA Output Voltage Swing High2 15V (V) +VOUT2_14 15V VS=+/-15V IL=1mA Output Voltage Swing High3 15V (V) +VOUT3_14 15V VS=+/-15V IL=10mA Output Voltage Swing Low1 15V (V) -VOUT1_14 15V VS=+/-15V IL=0mA Output Voltage Swing Low2 15V (V) -VOUT2_14 15V VS=+/-15V IL=1mA Output Voltage Swing Low3 15V (V) -VOUT3_14 15V VS=+/-15V IL=10mA Large Signal Voltage Gain1 15V (V/mV) AVOL1_14 15V VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain2 15V (V/mV) AVOL2_14 15V VO=+/-10V, RL=2kΩ Common Mode Rejection Ratio1 15V (dB) CMRR1_14 15V VS=+/-15V, VCM=+/-15V CMRR Match1 1 to 4 15V (dB) CMRR1 MATCH 1 to 4 15V VS=+/-15V, VCM=+/-15V CMRR Match1 2 to 3 15V (dB) CMRR1 MATCH 2 to 3 15V VS=+/-15V, VCM=+/-15V Power Supply Rejection Ratio1 (dB) PSRR1_14 VS=+/-2V to +/-16V PSRR Match1 1 to 4 (dB) PSRR1 MATCH 1 to 4 VS=+/-2V to +/-16V PSRR Match1 2 to 3 (dB) PSRR1 MATCH 2 to 3 VS=+/-2V to +/-16V An ISO 9001:2008 and DSCC Certified Company 410 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 +Short-Circuit Current1 15V (A) +ISC1_14 15V VS=+/-15V, VOUT=0V -Short-Circuit Current1 15V (A) -ISC1_14 15V VS=+/-15V, VOUT=0V +Supply Current 5V (A) +ICC5 VS=+5V -Supply Current 5V (A) -IEE5 VS=+5V Input Offset Voltage4 5V (V) VOS4_14 5V VS=+5V, VCM=0V Input Offset Current4 5V (A) IOS4_14 5V VS=+5V, VCM=0V +Input Bias Current BIAS4 5V (A) +IBIAS4_14 5V VS=+5V, VCM=0V -Input Bias Current BIAS4 5V (A) -IBIAS4_14 5V VS=+5V, VCM=0V Input Offset Voltage5 5V (V) VOS5_14 5V VS=+5V, VCM=5V Input Offset Current5 5V (A) IOS5_14 5V VS=+5V, VCM=5V +Input Bias Current BIAS5 5V (A) +IBIAS5_14 5V VS=+5V, VCM=5V -Input Bias Current BIAS5 5V (A) -IBIAS5_14 5V VS=+5V, VCM=5V Output Voltage Swing High4 5V (V) +VOUT4_14 5V VS=+5V IL=0mA Output Voltage Swing High5 5V (V) +VOUT5_14 5V VS=+5V IL=1mA Output Voltage Swing High6 5V (V) +VOUT6_14 5V VS=+5V IL=2.5mA Output Voltage Swing Low4 5V (V) -VOUT4_14 5V VS=+5V IL=0mA Output Voltage Swing Low5 5V (V) -VOUT5_14 5V VS=+5V IL=1mA Output Voltage Swing Low6 5V (V) -VOUT6_14 5V VS=+5V IL=2.5mA Large Signal Voltage Gain3 5V (V/mV) AVOL3_14 5V VO=75mV to 4.8V, RL=10kΩ Common Mode Rejection Ratio2 5V (dB) CMRR2_14 5V VS=+5V, VCM=0 to +5V CMRR Match2 1 to 4 5V (dB) CMRR2 MATCH 1 to 4 5V VS=+5V, VCM=0 to +5V CMRR Match2 2 to 3 5V (dB) CMRR2 MATCH 2 to 3 5V VS=+5V, VCM=0 to +5V Power Supply Rejection Ratio2 (dB) PSRR2_14 VS=+4.5V to +12V PSRR Match2 1 to 4 (dB) PSRR2 MATCH 1 to 4 VS=+4.5V to +12V PSRR Match2 2 to 3 (dB) PSRR2 MATCH 2 to 3 VS=+4.5V to +12V +Short-Circuit Current2 5V (A) +ISC2_14 5V VS=+5V -Short-Circuit Current2 5V (A) -ISC2_14 5V VS=+5V Gain-Bandwidth Product 15V (MHz) GBW_14 15V +Slew Rate 15V (V/us) +SR_14 5V -Slew Rate 15V (V/us) -SR_14 5V VS=+/-15V, f=100kHz VS=+/-15V, AV=-1, RL=10K, VO=+/-10V VS=+/-15V, AV=-1, RL=10K, VO=+/-10V An ISO 9001:2008 and DSCC Certified Company 411 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp. Pre-Irradiation Specification MIN MAX Parameter +Supply Current 15V (A) 1.00E-02 Measurement Precision/Resolution ±1.64E-04 -Supply Current 15V (A) -1.00E-02 ±1.61E-04 Input Offset Voltage1 15V (V) -8.00E-04 8.00E-04 ±2.51E-05 Input Offset Current1 15V (A) -7.00E-08 7.00E-08 ±9.10E-10 +Input Bias Current BIAS1 15V (A) -7.15E-07 7.15E-07 ±1.22E-08 -Input Bias Current BIAS1 15V (A) -7.15E-07 7.15E-07 ±1.13E-08 Input Offset Voltage2 15V (V) -8.00E-04 8.00E-04 ±1.28E-05 Input Offset Current2 15V (A) -7.00E-08 7.00E-08 ±9.67E-10 +Input Bias Current BIAS2 15V (A) -7.15E-07 7.15E-07 ±7.21E-09 -Input Bias Current BIAS2 15V (A) -7.15E-07 7.15E-07 ±6.44E-09 Input Offset Voltage3 15V (V) -8.00E-04 8.00E-04 ±1.65E-05 Input Offset Current3 15V (A) -7.00E-08 7.00E-08 ±7.00E-10 +Input Bias Current BIAS3 15V (A) -7.15E-07 7.15E-07 ±1.01E-08 -Input Bias Current BIAS3 15V (A) -7.15E-07 7.15E-07 ±8.88E-09 Output Voltage Swing High1 15V (V) 1.00E-02 ±2.81E-04 Output Voltage Swing High2 15V (V) 1.50E-01 ±1.19E-03 Output Voltage Swing High3 15V (V) 8.00E-01 ±6.15E-03 Output Voltage Swing Low1 15V (V) 3.00E-02 ±5.56E-04 Output Voltage Swing Low2 15V (V) 1.00E-01 ±1.03E-03 Output Voltage Swing Low3 15V (V) 5.00E-01 ±3.44E-03 Large Signal Voltage Gain1 15V (V/mV) 1.00E+03 ±2.28E+02 Large Signal Voltage Gain2 15V (V/mV) Common Mode Rejection Ratio1 15V (dB) CMRR Match1 1 to 4 15V (dB) 5.00E+01 ±1.55E+01 9.00E+01 3.00E+02 ±9.45E-02 8.40E+01 3.00E+02 ±6.79E-02 CMRR Match1 2 to 3 15V (dB) 8.40E+01 3.00E+02 ±1.71E-01 Power Supply Rejection Ratio1 (dB) 9.00E+01 ±3.82E-01 PSRR Match1 1 to 4 (dB) 8.30E+01 ±1.35E-01 An ISO 9001:2008 and DSCC Certified Company 412 ELDRS Report 12-640 130125 R1.1 PSRR Match1 2 to 3 (dB) 8.30E+01 +Short-Circuit Current1 15V (A) -Short-Circuit Current1 15V (A) ±8.96E-02 -1.50E-02 1.50E-02 +Supply Current 5V (A) Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ±4.01E-04 ±6.44E-04 8.80E-03 ±8.67E-05 -Supply Current 5V (A) -8.80E-03 ±8.59E-05 Input Offset Voltage4 5V (V) -8.00E-04 8.00E-04 ±1.49E-05 Input Offset Current4 5V (A) -6.50E-08 6.50E-08 ±5.28E-10 +Input Bias Current BIAS4 5V (A) -6.50E-07 6.50E-07 ±6.11E-09 -Input Bias Current BIAS4 5V (A) -6.50E-07 6.50E-07 ±6.24E-09 Input Offset Voltage5 5V (V) -8.00E-04 8.00E-04 ±8.65E-06 Input Offset Current5 5V (A) -6.50E-08 6.50E-08 ±5.15E-10 +Input Bias Current BIAS5 5V (A) -6.50E-07 6.50E-07 ±3.27E-09 -Input Bias Current BIAS5 5V (A) -6.50E-07 6.50E-07 ±2.91E-09 Output Voltage Swing High4 5V (V) 1.00E-02 ±2.53E-04 Output Voltage Swing High5 5V (V) 1.50E-01 ±8.19E-04 Output Voltage Swing High6 5V (V) 2.50E-01 ±1.46E-03 Output Voltage Swing Low4 5V (V) 3.00E-02 ±3.86E-04 Output Voltage Swing Low5 5V (V) 1.00E-01 ±4.14E-04 Output Voltage Swing Low6 5V (V) 2.00E-01 ±7.42E-04 Large Signal Voltage Gain3 5V (V/mV) 6.00E+02 ±5.72E+02 Common Mode Rejection Ratio2 5V (dB) 7.60E+01 ±1.49E-01 CMRR Match2 1 to 4 5V (dB) 7.50E+01 ±5.95E-02 CMRR Match2 2 to 3 5V (dB) 7.50E+01 ±3.80E-01 Power Supply Rejection Ratio2 (dB) 8.80E+01 ±4.26E+00 PSRR Match2 1 to 4 (dB) 8.20E+01 ±1.05E+00 PSRR Match2 2 to 3 (dB) 8.20E+01 ±6.39E-01 +Short-Circuit Current2 5V (A) -1.25E-02 ±4.02E-05 -Short-Circuit Current2 5V (A) 1.25E-02 ±4.63E-04 Gain-Bandwidth Product 15V (MHz) 6.80E+00 ±3.78E-02 +Slew Rate 15V (V/us) 3.50E+00 ±5.70E-02 -Slew Rate 15V (V/us) 3.50E+00 ±5.70E-02 An ISO 9001:2008 and DSCC Certified Company 413 ELDRS Report 12-640 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix D: List of Figures Used in the Results Section (Section 5) 5.1. 5.2. 5.3. 5.4. 5.5. 5.6. 5.7. 5.8. 5.9. 5.10. 5.11. 5.12. 5.13. 5.14. 5.15. 5.16. 5.17. 5.18. 5.19. 5.20. 5.21. 5.22. 5.23. 5.24. 5.25. 5.26. 5.27. 5.28. 5.29. 5.30. 5.31. 5.32. 5.33. 5.34. 5.35. 5.36. 5.37. 5.38. 5.39. 5.40. 5.41. 5.42. 5.43. 5.44. +Supply Current 15V (A) @ VS=+/-15V -Supply Current 15V (A) @ VS=+/-15V Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V An ISO 9001:2008 and DSCC Certified Company 414 ELDRS Report 12-640 130125 R1.1 5.45. 5.46. 5.47. 5.48. 5.49. 5.50. 5.51. 5.52. 5.53. 5.54. 5.55. 5.56. 5.57. 5.58. 5.59. 5.60. 5.61. 5.62. 5.63. 5.64. 5.65. 5.66. 5.67. 5.68. 5.69. 5.70. 5.71. 5.72. 5.73. 5.74. 5.75. 5.76. 5.77. 5.78. 5.79. 5.80. 5.81. 5.82. 5.83. 5.84. 5.85. 5.86. 5.87. 5.88. 5.89. 5.90. +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V An ISO 9001:2008 and DSCC Certified Company 415 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ELDRS Report 12-640 130125 R1.1 5.91. 5.92. 5.93. 5.94. 5.95. 5.96. 5.97. 5.98. 5.99. 5.100. 5.101. 5.102. 5.103. 5.104. 5.105. 5.106. 5.107. 5.108. 5.109. 5.110. 5.111. 5.112. 5.113. 5.114. 5.115. 5.116. 5.117. 5.118. 5.119. 5.120. 5.121. 5.122. 5.123. 5.124. 5.125. 5.126. 5.127. 5.128. 5.129. 5.130. 5.131. 5.132. 5.133. 5.134. 5.135. 5.136. Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V +Supply Current 5V (A) @ VS=+5V -Supply Current 5V (A) @ VS=+5V Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V An ISO 9001:2008 and DSCC Certified Company 416 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ELDRS Report 12-640 130125 R1.1 5.137. 5.138. 5.139. 5.140. 5.141. 5.142. 5.143. 5.144. 5.145. 5.146. 5.147. 5.148. 5.149. 5.150. 5.151. 5.152. 5.153. 5.154. 5.155. 5.156. 5.157. 5.158. 5.159. 5.160. 5.161. 5.162. 5.163. 5.164. 5.165. 5.166. 5.167. 5.168. 5.169. 5.170. 5.171. 5.172. 5.173. 5.174. 5.175. 5.176. 5.177. 5.178. 5.179. 5.180. 5.181. 5.182. Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V +Short-Circuit Current2 1 5V (A) @ VS=+5V +Short-Circuit Current2 2 5V (A) @ VS=+5V +Short-Circuit Current2 3 5V (A) @ VS=+5V +Short-Circuit Current2 4 5V (A) @ VS=+5V -Short-Circuit Current2 1 5V (A) @ VS=+5V -Short-Circuit Current2 2 5V (A) @ VS=+5V An ISO 9001:2008 and DSCC Certified Company 417 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ELDRS Report 12-640 130125 R1.1 5.183. 5.184. 5.185. 5.186. 5.187. 5.188. 5.189. 5.190. 5.191. 5.192. 5.193. 5.194. 5.195. 5.196. -Short-Circuit Current2 3 5V (A) @ VS=+5V -Short-Circuit Current2 4 5V (A) @ VS=+5V Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz +Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ +Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ +Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ +Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ -Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ -Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ -Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ -Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ An ISO 9001:2008 and DSCC Certified Company 418 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800