ELDRS_50K_Report_RH1499MW_Fab_Lot_W1046927_1_W1.pdf

ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Products contained in this shipment may be subject to ITAR
regulations.
Warning:
The export of these commodity(ies), technology, or software are subject either to the
U.S. Commerce Department Export Administration Regulations (E.A.R.), or to the U.S.
State Department International Traffic In Arms Regulations (I.T.A.R.). Diversion, the
shipment to unauthorized locations or entities, or the disclosure of related technical data
or software to unauthorized foreign nationals is contrary to U.S. law and is prohibited. If
export is authorized to a specific country or end-users, compliance with the U.S. export
laws is required prior to transfer, transshipment on a non-continuous voyage, or disposal
in any other country, or to any other end-user of these commodities, either in their
original form or after being incorporated into other end-items.
An ISO 9001:2008 and DSCC Certified Company
1
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Enhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the
RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp
for Linear Technology
Customer: Linear Technology, PO# 5259J
RAD Job Number: 12-640
Part Type Tested: RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp.
Traceability Information: Fab Lot Number: W1046927.1, Wafer Number: 1, Assembly Lot
Number:656718.1, Date Code: 1203A. See photograph of unit under test in Appendix A.
Quantity of Units: 22 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 2
units for control. Serial numbers 557, 563, 564, 567 and 569 were biased during irradiation, serial
numbers 570, 571, 572, 573 and 574 were unbiased during irradiation and serial numbers 584 and 585
were used as control. See Appendix B for the radiation bias connection table.
Radiation and Electrical Test Increments: 10mrad(Si)/s ionizing radiation with electrical test
increments: pre-irradiation, 10krad(Si), 20krad(Si), 30krad(Si) and 50krad(Si).
Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD
Overtest and Post-Irradiation Anneal: No overtest. 24-hour room temperature anneal followed by a
168-hour 100°C anneal. Both anneals were performed in the same electrical bias condition as the
irradiations. Electrical measurements were made following each anneal increment.
Radiation Test Standard: MIL-STD-750E TM1019 and/or MIL-STD-883H TM1019 Condition D.
Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS04, Calibration Date:
4/26/2012, Calibration Due: 4/26/2013. LTS2101 Family Board, Entity ID FB10. LTS0600 Test Fixture,
Entity ID TF03. RH1499 BGSS 061114 DUT Board. Test Program: RH1499X.SRC
Facility and Radiation Source: Aeroflex RAD's Longmire Laboratories, Colorado Springs, CO.
Gamma rays provided by Co60 (GB-150) low dose rate source. Dosimetry performed by Air Ionization
Chamber (AIC) traceable to NIST. Aeroflex RAD's dosimetry has been audited by DSCC and Aeroflex
RAD has been awarded Laboratory Suitability for MIL-STD-750 and MIL-STD-883 TM 1019.
Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and
MIL-STD-750.
Low Dose Rate Test Result: PASSED the enhanced low dose rate sensitivity
test to the maximum tested dose level of 50krad(Si) with all parameters
remaining within their datasheet specifications.
An ISO 9001:2008 and DSCC Certified Company
2
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
1.0. Overview and Background
It is well known that total dose ionizing radiation can cause parametric degradation and ultimately
functional failure in electronic devices. The damage occurs via electron-hole pair production, transport
and trapping in the dielectric regions. In advanced CMOS technology nodes (0.6µm and smaller) the
bulk of the damage is manifested in the thicker isolation regions, such as shallow trench or local
oxidation of silicon (LOCOS) oxides (also known as "birds-beak" oxides). However, many linear and
mixed signal devices that utilize bipolar minority carrier elements exhibit an enhanced low dose rate
sensitivity (ELDRS). At this time there is no known or accepted a priori method for predicting
susceptibility to ELDRS or simulating the low dose rate sensitivity with a "conventional" room
temperature 50-300rad(Si)/s irradiation (Condition A in MIL-STD-883 TM 1019.8). Over the past 10
years a number of accelerating techniques have been examined, including an elevated temperature
anneal, such as that used for MOS devices (see ASTM-F-1892 for more technical details) and irradiating
at various temperatures. However, none of these techniques have proven useful across the wide variety
of linear and/or mixed signal devices used in spaceborne applications.
The latest requirement incorporated in MIL-STD-883 TM 1019 requires that devices that could
potentially exhibit ELDRS "shall be tested either at the intended application dose rate, at a prescribed
low dose rate to an overtest radiation level, or with an accelerated test such as an elevated temperature
irradiation test that includes a parameter delta design margin". While the recently released MIL-STD883 TM 1019 allows for accelerated testing, the requirements for this are to essentially perform a low
dose rate ELDRS test to verify the suitability of the acceleration method on the component of interest
before the acceleration technique can be instituted. Based on the limitations of accelerated testing and to
meet the requirements of MIL-STD-883 TM1019.8 Condition D, we have performed a low dose rate test
at 10mrad(Si)/s.
2.0. Radiation Test Apparatus
The low dose rate testing described in this final report was performed using the facilities at Aeroflex
RAD's Longmire Laboratories in Colorado Springs, CO. The low dose rate source is a GB-150 irradiator
modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily
shielded by lead. During the irradiation exposures the rod is raised by an electronic timer/controller and
the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from
approximately 1mrad(Si)/s to a maximum of approximately 50rad(Si)/s, determined by the distance
from the source. For low dose rate testing described in this report, the devices are placed approximately
2-meters from the Co-60 rods. The irradiator calibration is maintained by Aeroflex RAD's Longmire
Laboratories using air ionization chamber (AIC) dosimetry traceable to the National Institute of
Standards and Technology (NIST). Figure 2.1 shows a photograph of the GB-150 Co-60 irradiator at
Aeroflex RAD's Longmire Laboratory facility.
An ISO 9001:2008 and DSCC Certified Company
3
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Figure 2.1. Aeroflex RAD's Co-60 irradiator. The dose rate is obtained by positioning the device-under-test at a
fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately 50rad(Si)/s close
to the rods down to <1mrad(Si)/s at a distance of approximately 4-meters.
An ISO 9001:2008 and DSCC Certified Company
4
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
3.0. Radiation Test Conditions
The RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp described in this final
report were irradiated using a split 15V supply and with all pins tied to ground, that is biased and
unbiased. See Appendix B for details on the biasing conditions during radiation exposure. In our
opinion, this bias circuit satisfies the requirements of MIL-STD-883H TM1019.8 Section 3.9.3 Bias and
Loading Conditions which states "The bias applied to the test devices shall be selected to produce the
greatest radiation induced damage or the worst-case damage for the intended application, if known.
While maximum voltage is often worst case some bipolar linear device parameters (e.g. input bias
current or maximum output load current) exhibit more degradation with 0 V bias."
The devices were irradiated to a maximum total ionizing dose level of 50krad(Si) with incremental
readings at 10krad(Si), 20krad(Si) and 30krad(Si). Electrical testing occurred within one hour following
the end of each irradiation segment. For intermediate irradiations, the units were tested and returned to
total dose exposure within two hours from the end of the previous radiation increment. The radiation
exposure bias board was positioned in the Co-60 cell to provide the targeted dose rate of10mrad(Si)/s
and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019.8 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test
specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm
Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and
for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1)
initially, (2) when the source is changed, or (3) when the orientation or configuration of the source,
container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g.,
a TLD) in the device-irradiation container at the approximate test-device position. If it can be
demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors
due to dose enhancement, the Pb/Al container may be omitted".
The final dose rate within the lead-aluminum box was determined based on air ionization chamber
(AIC) dosimetry measurements just prior to the beginning of the total dose irradiations. The final dose
rate for this work was 10mrad(Si)/s with a precision of ±5%.
An ISO 9001:2008 and DSCC Certified Company
5
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
4.0. Tested Parameters
During the enhanced low dose rate sensitivity testing the following electrical parameters were measured
pre- and post-irradiation:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
+Supply Current 15V (A) @ VS=+/-15V
-Supply Current 15V (A) @ VS=+/-15V
Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V
Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V
Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V
Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V
Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V
Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V
Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V
Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V
+Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V
+Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V
+Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V
+Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V
-Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V
-Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V
-Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V
-Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V
Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V
Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V
Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V
Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V
Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V
Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V
Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V
Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V
+Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V
+Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V
+Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V
+Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V
-Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V
-Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V
-Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V
-Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V
Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V
Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V
Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V
Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V
Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V
Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V
Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V
An ISO 9001:2008 and DSCC Certified Company
6
ELDRS Report
12-640 130125 R1.1
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V
+Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V
+Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V
+Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V
+Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V
-Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V
-Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V
-Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V
-Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V
Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA
Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ
Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ
Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ
Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ
Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ
Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ
Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ
Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ
Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V
Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V
Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V
Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V
CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V
An ISO 9001:2008 and DSCC Certified Company
7
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
ELDRS Report
12-640 130125 R1.1
88. CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V
89. Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V
90. Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V
91. Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V
92. Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V
93. PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V
94. PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V
95. +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V
96. +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V
97. +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V
98. +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V
99. -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V
100. -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V
101. -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V
102. -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V
103. +Supply Current 5V (A) @ VS=+5V
104. -Supply Current 5V (A) @ VS=+5V
105. Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V
106. Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V
107. Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V
108. Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V
109. Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V
110. Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V
111. Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V
112. Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V
113. +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V
114. +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V
115. +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V
116. +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V
117. -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V
118. -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V
119. -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V
120. -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V
121. Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V
122. Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V
123. Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V
124. Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V
125. Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V
126. Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V
127. Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V
128. Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V
129. +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V
130. +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V
131. +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V
132. +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V
133. -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V
An ISO 9001:2008 and DSCC Certified Company
8
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
ELDRS Report
12-640 130125 R1.1
134. -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V
135. -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V
136. -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V
137. Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA
138. Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA
139. Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA
140. Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA
141. Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA
142. Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA
143. Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA
144. Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA
145. Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA
146. Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA
147. Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA
148. Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA
149. Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA
150. Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA
151. Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA
152. Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA
153. Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA
154. Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA
155. Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA
156. Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA
157. Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA
158. Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA
159. Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA
160. Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA
161. Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ
162. Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ
163. Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ
164. Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ
165. Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V
166. Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V
167. Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V
168. Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V
169. CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V
170. CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V
171. Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V
172. Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V
173. Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V
174. Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V
175. PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V
176. PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V
177. +Short-Circuit Current2 1 5V (A) @ VS=+5V
178. +Short-Circuit Current2 2 5V (A) @ VS=+5V
179. +Short-Circuit Current2 3 5V (A) @ VS=+5V
An ISO 9001:2008 and DSCC Certified Company
9
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
180. +Short-Circuit Current2 4 5V (A) @ VS=+5V
181. -Short-Circuit Current2 1 5V (A) @ VS=+5V
182. -Short-Circuit Current2 2 5V (A) @ VS=+5V
183. -Short-Circuit Current2 3 5V (A) @ VS=+5V
184. -Short-Circuit Current2 4 5V (A) @ VS=+5V
185. Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz
186. Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz
187. Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz
188. Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz
189. +Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
190. +Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
191. +Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
192. +Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
193. -Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
194. -Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
195. -Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
196. -Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
Appendix C details the measured parameters, test conditions, pre-irradiation specification and
measurement resolution for each of the measurements.
The parametric data was obtained as "read and record" and all the raw data plus an attributes summary
are contained in this report as well as in a separate Excel file. The attributes data contains the average,
standard deviation and the average with the KTL values applied. The KTL value used in this work is
2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The
90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535
sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the
following criteria must be met for a device to pass the low dose rate test: following the radiation
exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units
irradiated without electrical bias and the KTL statistics are included in this report for reference only. If
any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet
specification limits, then the lot could be logged as a failure.
Further, MIL-STD-883H, TM 1019.8 Section 3.13.1.1 Characterization test to determine if a part
exhibits ELDRS' states the following: Select a minimum random sample of 21 devices from a
population representative of recent production runs. Smaller sample sizes may be used if agreed upon
between the parties to the test. All of the selected devices shall have undergone appropriate elevated
temperature reliability screens, e.g. burn-in and high temperature storage life. Divide the samples into
four groups of 5 each and use the remaining part for a control. Perform pre-irradiation electrical
characterization on all parts assuring that they meet the Group A electrical tests. Irradiate 5 samples
under a 0 volt bias and another 5 under the irradiation bias given in the acquisition specification at 50300 rad(Si)/s and room temperature. Irradiate 5 samples under a 0 volt bias and another 5 under
irradiation bias given in the acquisition specification at < 10mrad(Si)/s and room temperature. Irradiate
all samples to the same dose levels, including 0.5 and 1.0 times the anticipated specification dose, and
An ISO 9001:2008 and DSCC Certified Company
10
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
repeat the electrical characterization on each part at each dose level. Post irradiation electrical
measurements shall be performed per paragraph 3.10 where the low dose rate test is considered
Condition D. Calculate the radiation induced change in each electrical parameter (∆para) for each
sample at each radiation level. Calculate the ratio of the median ∆para at low dose rate to the median
∆para at high dose rate for each irradiation bias group at each total dose level. If this ratio exceeds 1.5
for any of the most sensitive parameters then the part is considered to be ELDRS susceptible. This test
does not apply to parameters which exhibit changes that are within experimental error or whose values
are below the pre-irradiation electrical specification limits at low dose rate at the specification dose.
Therefore, the data in this report can be analyzed along with the high dose rate report titled "Total
Ionizing Dose (TID) Radiation Testing of the RH1499MW Quad Rail-to-Rail Input and Output
Precision C-Load Op Amp for Linear Technology" to demonstrate that these parts do not exhibit
ELDRS as defined in the current test method.
An ISO 9001:2008 and DSCC Certified Company
11
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
5.0. ELDRS Test Results
Based on this criterion the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp
(from the lot traceability information provided on the first page of this test report) PASSED the
enhanced low dose rate sensitivity test to the maximum tested dose level of 50krad(Si) with all
parameters remaining within their datasheet specifications.
Figures 5.1 through 5.196 show plots of all the measured parameters versus total ionizing dose while
Tables 5.1 - 5.196 show the corresponding raw data for each of these parameters. In the data plots the
solid diamonds are the average of the measured data points for the sample irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the units irradiated with all
pins tied to ground. The black lines (solid or dashed) are the average of the data points after application
of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or
dashed) are the average of the data points after application of the KTL statistics on the sample irradiated
in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or
maximum specification value as defined in the datasheet and/or test plan.
In addition to the radiation test results, the data plots and tables described above contain anneal data.
The anneals are performed to better understand the underlying physical mechanisms responsible for
radiation-induced parametric shifts and are not part of the criteria used to establish whether or not the lot
passes or fails the low dose rate test. In all cases the parts either improved or exhibited no change during
the anneal.
The control units, as expected, show no significant changes to any of the parameters. Therefore we can
conclude that the electrical testing remained in control throughout the duration of the tests and the
observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section
to facilitate the location of a particular parameter.
An ISO 9001:2008 and DSCC Certified Company
12
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Ps90%/90% (+KTL) Biased
+Supply Current 15V (A) @ VS=+/-15V
1.20E-02
1.00E-02
8.00E-03
6.00E-03
4.00E-03
2.00E-03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.1. Plot of +Supply Current 15V (A) @ VS=+/-15V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
13
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.1. Raw data for +Supply Current 15V (A) @ VS=+/-15V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
+Supply Current 15V (A)
@ VS=+/-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
0
7.80E-03
7.75E-03
7.75E-03
7.69E-03
7.72E-03
7.71E-03
7.64E-03
7.79E-03
7.56E-03
7.73E-03
7.71E-03
7.77E-03
10
7.75E-03
7.72E-03
7.73E-03
7.68E-03
7.69E-03
7.68E-03
7.58E-03
7.75E-03
7.55E-03
7.69E-03
7.72E-03
7.74E-03
Total Dose (krad(Si))
20
30
7.75E-03 7.74E-03
7.69E-03 7.70E-03
7.71E-03 7.74E-03
7.65E-03 7.65E-03
7.66E-03 7.66E-03
7.67E-03 7.65E-03
7.57E-03 7.57E-03
7.74E-03 7.72E-03
7.52E-03 7.50E-03
7.69E-03 7.68E-03
7.72E-03 7.72E-03
7.82E-03 7.76E-03
50
7.69E-03
7.64E-03
7.65E-03
7.59E-03
7.60E-03
7.58E-03
7.54E-03
7.67E-03
7.44E-03
7.61E-03
7.68E-03
7.76E-03
24 Hr
Anneal
60
7.68E-03
7.63E-03
7.64E-03
7.57E-03
7.60E-03
7.58E-03
7.49E-03
7.66E-03
7.43E-03
7.61E-03
7.65E-03
7.70E-03
168 Hr
Anneal
70
7.70E-03
7.67E-03
7.68E-03
7.61E-03
7.62E-03
7.61E-03
7.52E-03
7.68E-03
7.46E-03
7.63E-03
7.67E-03
7.73E-03
Biased Statistics
Average Biased
7.74E-03 7.71E-03 7.69E-03 7.70E-03 7.63E-03 7.62E-03 7.66E-03
Std Dev Biased
3.98E-05 3.01E-05 3.86E-05 4.31E-05 4.23E-05 4.18E-05 3.82E-05
Ps90%/90% (+KTL) Biased
7.85E-03 7.79E-03 7.80E-03 7.81E-03 7.75E-03 7.74E-03 7.76E-03
Ps90%/90% (-KTL) Biased
7.63E-03 7.63E-03 7.58E-03 7.58E-03 7.52E-03 7.51E-03 7.55E-03
Un-Biased Statistics
Average Un-Biased
7.69E-03 7.65E-03 7.64E-03 7.63E-03 7.57E-03 7.56E-03 7.58E-03
Std Dev Un-Biased
9.16E-05 8.18E-05 9.19E-05 8.73E-05 8.75E-05 8.99E-05 9.02E-05
Ps90%/90% (+KTL) Un-Biased
7.94E-03 7.87E-03 7.89E-03 7.86E-03 7.81E-03 7.80E-03 7.83E-03
Ps90%/90% (-KTL) Un-Biased
7.43E-03 7.43E-03 7.39E-03 7.39E-03 7.33E-03 7.31E-03 7.33E-03
Specification MAX
1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
14
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
-Supply Current 15V (A) @ VS=+/-15V
0.00E+00
-2.00E-03
-4.00E-03
-6.00E-03
-8.00E-03
-1.00E-02
-1.20E-02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.2. Plot of -Supply Current 15V (A) @ VS=+/-15V versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
15
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.2. Raw data for -Supply Current 15V (A) @ VS=+/-15V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
-Supply Current 15V (A)
@ VS=+/-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
0
-7.82E-03
-7.77E-03
-7.77E-03
-7.71E-03
-7.74E-03
-7.73E-03
-7.66E-03
-7.82E-03
-7.58E-03
-7.75E-03
-7.73E-03
-7.79E-03
Biased Statistics
Average Biased
-7.76E-03
Std Dev Biased
3.98E-05
Ps90%/90% (+KTL) Biased
-7.65E-03
Ps90%/90% (-KTL) Biased
-7.87E-03
Un-Biased Statistics
Average Un-Biased
-7.71E-03
Std Dev Un-Biased
9.12E-05
Ps90%/90% (+KTL) Un-Biased -7.46E-03
Ps90%/90% (-KTL) Un-Biased
-7.96E-03
Specification MIN
-1.00E-02
Status
PASS
10
-7.78E-03
-7.74E-03
-7.75E-03
-7.70E-03
-7.71E-03
-7.70E-03
-7.61E-03
-7.77E-03
-7.57E-03
-7.71E-03
-7.75E-03
-7.76E-03
Total Dose (krad(Si))
20
30
-7.77E-03 -7.77E-03
-7.71E-03 -7.72E-03
-7.73E-03 -7.76E-03
-7.67E-03 -7.67E-03
-7.68E-03 -7.68E-03
-7.69E-03 -7.67E-03
-7.59E-03 -7.60E-03
-7.76E-03 -7.75E-03
-7.54E-03 -7.53E-03
-7.72E-03 -7.70E-03
-7.74E-03 -7.74E-03
-7.84E-03 -7.78E-03
50
-7.71E-03
-7.66E-03
-7.67E-03
-7.61E-03
-7.62E-03
-7.60E-03
-7.56E-03
-7.69E-03
-7.46E-03
-7.64E-03
-7.70E-03
-7.79E-03
24 Hr
Anneal
60
-7.71E-03
-7.65E-03
-7.66E-03
-7.59E-03
-7.62E-03
-7.60E-03
-7.51E-03
-7.68E-03
-7.45E-03
-7.63E-03
-7.67E-03
-7.72E-03
168 Hr
Anneal
70
-7.72E-03
-7.70E-03
-7.70E-03
-7.63E-03
-7.65E-03
-7.63E-03
-7.54E-03
-7.70E-03
-7.48E-03
-7.65E-03
-7.69E-03
-7.75E-03
-7.73E-03 -7.71E-03 -7.72E-03 -7.66E-03 -7.65E-03 -7.68E-03
2.95E-05 3.85E-05 4.40E-05 4.16E-05 4.35E-05 3.73E-05
-7.65E-03 -7.61E-03 -7.60E-03 -7.54E-03 -7.53E-03 -7.58E-03
-7.81E-03 -7.82E-03 -7.84E-03 -7.77E-03 -7.76E-03 -7.78E-03
-7.67E-03
8.18E-05
-7.45E-03
-7.90E-03
-1.00E-02
PASS
-7.66E-03
9.32E-05
-7.40E-03
-7.92E-03
-1.00E-02
PASS
-7.65E-03
8.66E-05
-7.41E-03
-7.89E-03
-1.00E-02
PASS
-7.59E-03
8.80E-05
-7.35E-03
-7.83E-03
-1.00E-02
PASS
An ISO 9001:2008 and DSCC Certified Company
16
-7.58E-03
9.20E-05
-7.32E-03
-7.83E-03
-1.00E-02
PASS
-7.60E-03
9.10E-05
-7.35E-03
-7.85E-03
-1.00E-02
PASS
Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.3. Plot of Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
17
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.3. Raw data for Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage1 1 15V (V)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-1.48E-04
-2.10E-04
-4.82E-05
5.74E-05
-1.84E-04
5.61E-05
-3.67E-04
1.40E-04
-4.45E-05
-8.40E-06
-4.66E-04
1.51E-04
Total Dose (krad(Si))
20
30
-1.60E-04 -1.61E-04
-2.21E-04 -2.22E-04
-5.59E-05 -5.40E-05
4.52E-05 4.38E-05
-1.90E-04 -1.89E-04
4.24E-05 3.99E-05
-3.76E-04 -3.78E-04
1.25E-04 1.22E-04
-5.16E-05 -5.65E-05
-1.75E-05 -2.13E-05
-4.67E-04 -4.67E-04
1.53E-04 1.47E-04
10
-1.57E-04
-2.18E-04
-5.46E-05
4.73E-05
-1.91E-04
4.28E-05
-3.75E-04
1.26E-04
-4.97E-05
-1.89E-05
-4.67E-04
1.46E-04
50
-1.69E-04
-2.24E-04
-6.20E-05
4.32E-05
-1.93E-04
2.84E-05
-3.80E-04
1.22E-04
-6.55E-05
-2.74E-05
-4.70E-04
1.50E-04
24 Hr
Anneal
60
-1.68E-04
-2.26E-04
-6.43E-05
4.44E-05
-1.95E-04
2.82E-05
-3.82E-04
1.17E-04
-6.15E-05
-2.96E-05
-4.70E-04
1.43E-04
168 Hr
Anneal
70
-1.65E-04
-2.43E-04
-6.27E-05
3.74E-05
-1.94E-04
3.19E-05
-3.91E-04
1.16E-04
-7.41E-05
-2.98E-05
-4.69E-04
1.46E-04
-1.07E-04 -1.15E-04 -1.16E-04 -1.17E-04 -1.21E-04 -1.22E-04 -1.25E-04
1.10E-04 1.10E-04 1.09E-04 1.10E-04 1.10E-04 1.11E-04 1.12E-04
1.96E-04 1.86E-04 1.84E-04 1.84E-04 1.81E-04 1.82E-04 1.83E-04
-4.10E-04 -4.16E-04 -4.16E-04 -4.17E-04 -4.23E-04 -4.26E-04 -4.33E-04
-4.49E-05
1.93E-04
4.86E-04
-5.75E-04
-8.00E-04
PASS
8.00E-04
PASS
-5.50E-05
1.91E-04
4.69E-04
-5.79E-04
-9.50E-04
PASS
9.50E-04
PASS
-5.54E-05
1.91E-04
4.69E-04
-5.80E-04
-9.50E-04
PASS
9.50E-04
PASS
-5.90E-05
1.91E-04
4.65E-04
-5.82E-04
-9.50E-04
PASS
9.50E-04
PASS
-6.43E-05
1.90E-04
4.56E-04
-5.85E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
18
-6.56E-05
1.90E-04
4.54E-04
-5.85E-04
-9.50E-04
PASS
9.50E-04
PASS
-6.95E-05
1.94E-04
4.61E-04
-6.00E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.4. Plot of Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
19
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.4. Raw data for Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage1 2 15V (V)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-1.52E-04
-2.29E-04
-5.87E-05
-1.74E-04
8.87E-06
-1.31E-04
3.05E-05
-2.01E-05
-2.13E-04
-1.07E-04
-2.87E-04
4.11E-05
Total Dose (krad(Si))
20
30
-1.62E-04 -1.60E-04
-2.35E-04 -2.37E-04
-6.16E-05 -6.21E-05
-1.79E-04 -1.79E-04
6.21E-06 6.81E-06
-1.39E-04 -1.41E-04
2.64E-05 2.66E-05
-3.87E-05 -3.99E-05
-2.17E-04 -2.20E-04
-1.13E-04 -1.14E-04
-2.89E-04 -2.88E-04
4.24E-05 3.93E-05
10
-1.61E-04
-2.37E-04
-6.36E-05
-1.76E-04
8.62E-06
-1.39E-04
2.60E-05
-3.63E-05
-2.18E-04
-1.11E-04
-2.88E-04
4.01E-05
50
-1.65E-04
-2.37E-04
-6.82E-05
-1.84E-04
6.22E-06
-1.44E-04
2.43E-05
-4.51E-05
-2.17E-04
-1.17E-04
-2.89E-04
4.26E-05
24 Hr
Anneal
60
-1.63E-04
-2.37E-04
-7.04E-05
-1.85E-04
7.30E-06
-1.42E-04
2.37E-05
-4.67E-05
-2.19E-04
-1.19E-04
-2.88E-04
3.63E-05
168 Hr
Anneal
70
-1.69E-04
-2.32E-04
-6.07E-05
-1.68E-04
3.55E-06
-1.42E-04
1.10E-05
-4.68E-05
-2.26E-04
-1.19E-04
-2.89E-04
3.88E-05
-1.21E-04 -1.26E-04 -1.26E-04 -1.26E-04 -1.30E-04 -1.30E-04 -1.25E-04
9.49E-05 9.76E-05 9.70E-05 9.74E-05 9.76E-05 9.75E-05 9.48E-05
1.39E-04 1.42E-04 1.40E-04 1.41E-04 1.38E-04 1.38E-04 1.35E-04
-3.81E-04 -3.94E-04 -3.92E-04 -3.93E-04 -3.97E-04 -3.97E-04 -3.85E-04
-8.82E-05
9.56E-05
1.74E-04
-3.50E-04
-8.00E-04
PASS
8.00E-04
PASS
-9.56E-05
9.41E-05
1.62E-04
-3.54E-04
-9.50E-04
PASS
9.50E-04
PASS
-9.62E-05
9.36E-05
1.61E-04
-3.53E-04
-9.50E-04
PASS
9.50E-04
PASS
-9.75E-05
9.45E-05
1.62E-04
-3.57E-04
-9.50E-04
PASS
9.50E-04
PASS
-9.99E-05
9.28E-05
1.55E-04
-3.54E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
20
-1.01E-04
9.28E-05
1.54E-04
-3.55E-04
-9.50E-04
PASS
9.50E-04
PASS
-1.04E-04
9.08E-05
1.44E-04
-3.53E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.5. Plot of Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
21
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.5. Raw data for Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage1 3 15V (V)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
2.57E-04
-4.40E-05
-5.19E-05
2.44E-05
-1.89E-04
-1.03E-04
-2.18E-04
1.66E-04
6.59E-05
3.01E-05
3.35E-04
-1.15E-06
Total Dose (krad(Si))
20
30
2.41E-04 2.37E-04
-5.26E-05 -5.34E-05
-6.08E-05 -5.84E-05
1.56E-05 1.76E-05
-1.98E-04 -2.01E-04
-1.12E-04 -1.14E-04
-2.30E-04 -2.31E-04
1.50E-04 1.46E-04
5.81E-05 5.80E-05
2.25E-05 1.74E-05
3.37E-04 3.37E-04
-1.88E-06 -4.06E-06
10
2.44E-04
-5.22E-05
-5.80E-05
1.88E-05
-1.94E-04
-1.10E-04
-2.27E-04
1.54E-04
5.99E-05
2.34E-05
3.38E-04
-4.05E-06
50
2.31E-04
-5.36E-05
-6.83E-05
1.50E-05
-2.06E-04
-1.18E-04
-2.38E-04
1.43E-04
5.27E-05
1.36E-05
3.34E-04
-1.39E-06
24 Hr
Anneal
60
2.31E-04
-5.42E-05
-7.15E-05
1.36E-05
-2.06E-04
-1.19E-04
-2.39E-04
1.40E-04
5.13E-05
1.26E-05
3.31E-04
-7.67E-06
168 Hr
Anneal
70
2.25E-04
-4.91E-05
-7.32E-05
7.42E-06
-1.99E-04
-1.14E-04
-2.25E-04
1.27E-04
4.73E-05
7.54E-06
3.32E-04
-5.86E-06
-5.78E-07 -8.21E-06 -1.10E-05 -1.15E-05 -1.65E-05 -1.74E-05 -1.78E-05
1.64E-04 1.61E-04 1.61E-04 1.60E-04 1.60E-04 1.60E-04 1.55E-04
4.48E-04 4.33E-04 4.30E-04 4.27E-04 4.22E-04 4.21E-04 4.07E-04
-4.49E-04 -4.49E-04 -4.52E-04 -4.50E-04 -4.55E-04 -4.56E-04 -4.43E-04
-1.18E-05
1.50E-04
4.00E-04
-4.23E-04
-8.00E-04
PASS
8.00E-04
PASS
-2.00E-05
1.49E-04
3.90E-04
-4.30E-04
-9.50E-04
PASS
9.50E-04
PASS
-2.23E-05
1.49E-04
3.87E-04
-4.32E-04
-9.50E-04
PASS
9.50E-04
PASS
-2.47E-05
1.49E-04
3.83E-04
-4.32E-04
-9.50E-04
PASS
9.50E-04
PASS
-2.93E-05
1.50E-04
3.81E-04
-4.40E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
22
-3.08E-05
1.49E-04
3.78E-04
-4.39E-04
-9.50E-04
PASS
9.50E-04
PASS
-3.15E-05
1.39E-04
3.50E-04
-4.13E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.6. Plot of Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
23
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.6. Raw data for Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage1 4 15V (V)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-1.03E-04
-7.33E-05
1.41E-04
1.30E-04
-3.39E-04
3.99E-05
1.21E-04
-6.99E-05
7.85E-05
-2.56E-04
3.18E-05
-2.69E-04
Total Dose (krad(Si))
20
30
-1.14E-04 -1.17E-04
-8.45E-05 -8.34E-05
1.35E-04 1.39E-04
1.23E-04 1.27E-04
-3.43E-04 -3.46E-04
3.27E-05 3.72E-05
1.11E-04 1.12E-04
-8.08E-05 -8.27E-05
7.32E-05 7.61E-05
-2.60E-04 -2.61E-04
3.07E-05 3.08E-05
-2.69E-04 -2.70E-04
10
-1.13E-04
-8.28E-05
1.36E-04
1.26E-04
-3.44E-04
3.23E-05
1.11E-04
-8.05E-05
7.15E-05
-2.63E-04
3.22E-05
-2.72E-04
50
-1.23E-04
-8.94E-05
1.32E-04
1.22E-04
-3.45E-04
4.01E-05
1.09E-04
-8.56E-05
7.35E-05
-2.62E-04
2.75E-05
-2.68E-04
24 Hr
Anneal
60
-1.22E-04
-9.18E-05
1.27E-04
1.20E-04
-3.44E-04
4.00E-05
1.06E-04
-8.63E-05
7.27E-05
-2.62E-04
2.40E-05
-2.72E-04
168 Hr
Anneal
70
-1.19E-04
-8.14E-05
1.29E-04
1.17E-04
-3.41E-04
3.18E-05
1.05E-04
-8.33E-05
6.10E-05
-2.72E-04
2.44E-05
-2.72E-04
-4.88E-05 -5.57E-05 -5.67E-05 -5.60E-05 -6.07E-05 -6.22E-05 -5.92E-05
1.98E-04 1.98E-04 1.97E-04 2.00E-04 1.98E-04 1.95E-04 1.93E-04
4.93E-04 4.87E-04 4.83E-04 4.92E-04 4.81E-04 4.73E-04 4.71E-04
-5.90E-04 -5.99E-04 -5.97E-04 -6.04E-04 -6.02E-04 -5.98E-04 -5.90E-04
-1.72E-05
1.51E-04
3.97E-04
-4.32E-04
-8.00E-04
PASS
8.00E-04
PASS
-2.58E-05
1.51E-04
3.87E-04
-4.39E-04
-9.50E-04
PASS
9.50E-04
PASS
-2.47E-05
1.50E-04
3.86E-04
-4.35E-04
-9.50E-04
PASS
9.50E-04
PASS
-2.38E-05
1.52E-04
3.92E-04
-4.40E-04
-9.50E-04
PASS
9.50E-04
PASS
-2.49E-05
1.51E-04
3.90E-04
-4.40E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
24
-2.59E-05
1.50E-04
3.87E-04
-4.39E-04
-9.50E-04
PASS
9.50E-04
PASS
-3.15E-05
1.52E-04
3.84E-04
-4.47E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.7. Plot of Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
25
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.7. Raw data for Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current1 1 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
2.69E-09
-4.40E-09
-7.80E-10
5.32E-09
1.41E-09
-6.10E-10
-5.92E-09
1.79E-09
-2.68E-09
4.79E-09
-7.55E-09
1.59E-09
10
2.54E-09
-4.95E-09
-1.07E-09
5.02E-09
9.00E-11
-8.90E-10
-6.11E-09
1.71E-09
-2.81E-09
4.55E-09
-8.16E-09
1.60E-10
Total Dose
20
1.88E-09
-5.17E-09
-1.63E-09
4.57E-09
-3.40E-10
-4.20E-10
-6.82E-09
1.79E-09
-3.10E-09
4.74E-09
-8.42E-09
-3.00E-11
(krad(Si))
30
1.36E-09
-5.57E-09
-2.18E-09
4.84E-09
-1.20E-09
-4.20E-10
-6.93E-09
1.94E-09
-2.94E-09
4.51E-09
-8.69E-09
8.00E-11
50
5.00E-10
-7.02E-09
-3.88E-09
4.15E-09
-2.19E-09
-4.80E-10
-6.93E-09
1.45E-09
-3.34E-09
5.55E-09
-8.84E-09
-5.00E-11
24 Hr
Anneal
60
-6.30E-10
-7.50E-09
-4.75E-09
3.53E-09
-2.94E-09
-7.10E-10
-8.02E-09
7.90E-10
-4.25E-09
3.99E-09
-9.11E-09
-9.00E-11
168 Hr
Anneal
70
1.02E-09
-6.07E-09
-3.29E-09
3.38E-09
-1.40E-09
-6.50E-10
-6.86E-09
1.06E-09
-3.29E-09
4.61E-09
-9.20E-09
-2.70E-10
8.48E-10 3.26E-10 -1.38E-10 -5.50E-10 -1.69E-09 -2.46E-09 -1.27E-09
3.67E-09 3.77E-09 3.67E-09 3.90E-09 4.25E-09 4.19E-09 3.67E-09
1.09E-08 1.07E-08 9.92E-09 1.02E-08 9.97E-09 9.02E-09 8.80E-09
-9.22E-09 -1.00E-08 -1.02E-08 -1.13E-08 -1.34E-08 -1.39E-08 -1.13E-08
-5.26E-10
4.10E-09
1.07E-08
-1.18E-08
-7.00E-08
PASS
7.00E-08
PASS
-7.10E-10
4.10E-09
1.05E-08
-1.19E-08
-1.00E-07
PASS
1.00E-07
PASS
-7.62E-10
4.45E-09
1.14E-08
-1.30E-08
-1.00E-07
PASS
1.00E-07
PASS
-7.68E-10
4.42E-09
1.13E-08
-1.29E-08
-1.00E-07
PASS
1.00E-07
PASS
-7.50E-10
4.73E-09
1.22E-08
-1.37E-08
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
26
-1.64E-09
4.64E-09
1.11E-08
-1.44E-08
-1.00E-07
PASS
1.00E-07
PASS
-1.03E-09
4.34E-09
1.09E-08
-1.29E-08
-1.00E-07
PASS
1.00E-07
PASS
Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.8. Plot of Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
27
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.8. Raw data for Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current1 2 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
2.87E-09
-2.46E-09
-2.76E-09
9.00E-11
2.82E-09
-2.56E-09
-1.09E-09
1.24E-09
2.10E-10
-2.40E-09
2.85E-09
1.97E-09
10
2.62E-09
-3.31E-09
-3.70E-09
-4.70E-10
3.14E-09
-2.69E-09
-1.62E-09
1.00E-09
-1.50E-10
-2.53E-09
2.38E-09
4.30E-10
Total Dose
20
2.22E-09
-3.44E-09
-4.53E-09
-6.80E-10
3.16E-09
-3.18E-09
-1.60E-09
1.21E-09
-5.10E-10
-3.06E-09
1.90E-09
2.30E-10
(krad(Si))
30
1.87E-09
-3.78E-09
-4.77E-09
-1.01E-09
2.76E-09
-3.34E-09
-9.50E-10
1.20E-09
-7.20E-10
-3.00E-09
1.66E-09
2.10E-10
50
5.10E-10
-4.33E-09
-5.57E-09
-1.85E-09
2.58E-09
-3.43E-09
-2.19E-09
1.49E-09
-6.10E-10
-2.36E-09
1.56E-09
2.50E-10
24 Hr
Anneal
60
6.00E-11
-5.24E-09
-6.37E-09
-2.43E-09
2.07E-09
-3.94E-09
-3.25E-09
5.50E-10
-1.05E-09
-3.49E-09
1.31E-09
2.60E-10
168 Hr
Anneal
70
9.30E-10
-4.13E-09
-4.98E-09
-2.08E-09
1.60E-09
-3.55E-09
-2.67E-09
1.21E-09
-3.70E-10
-2.94E-09
1.23E-09
1.90E-10
1.12E-10 -3.44E-10 -6.54E-10 -9.86E-10 -1.73E-09 -2.38E-09 -1.73E-09
2.73E-09 3.20E-09 3.38E-09 3.33E-09 3.36E-09 3.53E-09 2.94E-09
7.60E-09 8.43E-09 8.60E-09 8.14E-09 7.48E-09 7.30E-09 6.33E-09
-7.37E-09 -9.12E-09 -9.91E-09 -1.01E-08 -1.09E-08 -1.21E-08 -9.80E-09
-9.20E-10
1.65E-09
3.60E-09
-5.44E-09
-7.00E-08
PASS
7.00E-08
PASS
-1.20E-09
1.59E-09
3.16E-09
-5.56E-09
-1.00E-07
PASS
1.00E-07
PASS
-1.43E-09
1.84E-09
3.62E-09
-6.48E-09
-1.00E-07
PASS
1.00E-07
PASS
-1.36E-09
1.85E-09
3.72E-09
-6.44E-09
-1.00E-07
PASS
1.00E-07
PASS
-1.42E-09
1.91E-09
3.83E-09
-6.67E-09
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
28
-2.24E-09
1.92E-09
3.02E-09
-7.49E-09
-1.00E-07
PASS
1.00E-07
PASS
-1.66E-09
2.01E-09
3.84E-09
-7.17E-09
-1.00E-07
PASS
1.00E-07
PASS
Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.9. Plot of Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
29
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.9. Raw data for Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current1 3 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
3.99E-09
5.18E-09
3.84E-09
1.11E-08
7.50E-10
7.99E-09
1.44E-09
4.53E-09
8.00E-09
1.40E-10
5.40E-09
-8.40E-10
10
1.73E-09
3.48E-09
1.74E-09
9.38E-09
-1.41E-09
6.57E-09
-9.00E-11
3.10E-09
6.44E-09
-1.24E-09
3.91E-09
-3.49E-09
Total Dose
20
6.80E-10
2.21E-09
1.50E-10
7.63E-09
-2.75E-09
5.67E-09
-1.02E-09
2.21E-09
5.80E-09
-2.31E-09
2.67E-09
-4.29E-09
(krad(Si))
30
-5.60E-10
9.80E-10
-9.00E-10
6.86E-09
-4.21E-09
4.89E-09
-1.25E-09
1.24E-09
5.18E-09
-3.08E-09
1.90E-09
-4.93E-09
50
-1.73E-09
-3.80E-10
-2.13E-09
5.63E-09
-5.90E-09
4.04E-09
-2.65E-09
9.60E-10
4.28E-09
-3.44E-09
1.25E-09
-5.64E-09
24 Hr
Anneal
60
-2.38E-09
-1.36E-09
-2.30E-09
5.47E-09
-6.48E-09
3.42E-09
-3.17E-09
-1.70E-10
3.73E-09
-3.79E-09
1.17E-09
-5.78E-09
168 Hr
Anneal
70
-1.29E-09
-7.80E-10
-2.24E-09
6.12E-09
-4.59E-09
3.76E-09
-1.86E-09
9.50E-10
4.56E-09
-2.95E-09
1.17E-09
-5.54E-09
4.97E-09 2.98E-09 1.58E-09 4.34E-10 -9.02E-10 -1.41E-09 -5.56E-10
3.80E-09 3.99E-09 3.83E-09 4.06E-09 4.19E-09 4.32E-09 4.01E-09
1.54E-08 1.39E-08 1.21E-08 1.16E-08 1.06E-08 1.04E-08 1.04E-08
-5.45E-09 -7.95E-09 -8.91E-09 -1.07E-08 -1.24E-08 -1.33E-08 -1.15E-08
4.42E-09
3.63E-09
1.44E-08
-5.54E-09
-7.00E-08
PASS
7.00E-08
PASS
2.96E-09
3.61E-09
1.29E-08
-6.94E-09
-1.00E-07
PASS
1.00E-07
PASS
2.07E-09
3.73E-09
1.23E-08
-8.16E-09
-1.00E-07
PASS
1.00E-07
PASS
1.40E-09
3.66E-09
1.14E-08
-8.64E-09
-1.00E-07
PASS
1.00E-07
PASS
6.38E-10
3.62E-09
1.06E-08
-9.28E-09
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
30
4.00E-12
3.54E-09
9.70E-09
-9.70E-09
-1.00E-07
PASS
1.00E-07
PASS
8.92E-10
3.32E-09
9.99E-09
-8.20E-09
-1.00E-07
PASS
1.00E-07
PASS
Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.10. Plot of Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
31
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.10. Raw data for Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current1 4 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
1.06E-09
-2.10E-09
1.26E-08
6.14E-09
-3.46E-09
2.78E-09
6.18E-09
-2.00E-10
8.59E-09
1.74E-09
1.79E-09
-2.72E-09
10
-2.35E-09
-5.72E-09
9.17E-09
2.54E-09
-5.70E-09
-1.00E-10
3.24E-09
-3.05E-09
5.79E-09
-8.60E-10
-5.70E-10
-6.40E-09
Total Dose
20
-3.80E-09
-7.54E-09
6.30E-09
1.60E-10
-7.01E-09
-1.45E-09
2.39E-09
-4.01E-09
5.18E-09
-2.14E-09
-1.83E-09
-7.22E-09
(krad(Si))
30
-4.69E-09
-8.30E-09
5.26E-09
-5.30E-10
-8.29E-09
-1.51E-09
1.65E-09
-4.97E-09
4.88E-09
-2.04E-09
-2.41E-09
-7.57E-09
50
-5.64E-09
-9.31E-09
4.32E-09
-2.08E-09
-8.40E-09
-1.60E-09
1.52E-09
-4.48E-09
4.25E-09
-3.07E-09
-2.88E-09
-8.13E-09
24 Hr
Anneal
60
-6.27E-09
-1.06E-08
3.50E-09
-2.02E-09
-8.90E-09
-2.60E-09
8.00E-10
-5.48E-09
3.22E-09
-3.62E-09
-2.93E-09
-8.27E-09
168 Hr
Anneal
70
-5.35E-09
-9.33E-09
4.83E-09
-1.27E-09
-9.31E-09
-1.66E-09
1.46E-09
-5.14E-09
4.51E-09
-3.16E-09
-3.13E-09
-8.36E-09
2.84E-09 -4.12E-10 -2.38E-09 -3.31E-09 -4.22E-09 -4.87E-09 -4.09E-09
6.57E-09 6.33E-09 5.74E-09 5.76E-09 5.54E-09 5.69E-09 6.00E-09
2.08E-08 1.70E-08 1.34E-08 1.25E-08 1.10E-08 1.07E-08 1.24E-08
-1.52E-08 -1.78E-08 -1.81E-08 -1.91E-08 -1.94E-08 -2.05E-08 -2.05E-08
3.82E-09
3.53E-09
1.35E-08
-5.87E-09
-7.00E-08
PASS
7.00E-08
PASS
1.00E-09
3.50E-09
1.06E-08
-8.60E-09
-1.00E-07
PASS
1.00E-07
PASS
-6.00E-12
3.72E-09
1.02E-08
-1.02E-08
-1.00E-07
PASS
1.00E-07
PASS
-3.98E-10
3.77E-09
9.94E-09
-1.07E-08
-1.00E-07
PASS
1.00E-07
PASS
-6.76E-10
3.54E-09
9.03E-09
-1.04E-08
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
32
-1.54E-09
3.50E-09
8.07E-09
-1.11E-08
-1.00E-07
PASS
1.00E-07
PASS
-7.98E-10
3.82E-09
9.68E-09
-1.13E-08
-1.00E-07
PASS
1.00E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS1 1 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
Total Dose (krad(Si))
50
24
60Hr
Anneal
16870
Hr
Anneal
Figure 5.11. Plot of +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
33
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.11. Raw data for +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS1 1 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.89E-07
-3.13E-07
-3.21E-07
-3.31E-07
-3.17E-07
-3.23E-07
-3.10E-07
-3.04E-07
-3.12E-07
-3.09E-07
-2.88E-07
-2.97E-07
10
-2.97E-07
-3.25E-07
-3.33E-07
-3.46E-07
-3.31E-07
-3.27E-07
-3.15E-07
-3.09E-07
-3.14E-07
-3.13E-07
-2.87E-07
-3.00E-07
Total Dose (krad(Si))
20
30
-3.03E-07 -3.09E-07
-3.33E-07 -3.37E-07
-3.46E-07 -3.47E-07
-3.56E-07 -3.58E-07
-3.40E-07 -3.48E-07
-3.33E-07 -3.40E-07
-3.22E-07 -3.28E-07
-3.15E-07 -3.23E-07
-3.22E-07 -3.28E-07
-3.18E-07 -3.25E-07
-2.88E-07 -2.88E-07
-2.95E-07 -2.99E-07
50
-3.23E-07
-3.55E-07
-3.62E-07
-3.70E-07
-3.63E-07
-3.60E-07
-3.46E-07
-3.39E-07
-3.48E-07
-3.40E-07
-2.91E-07
-2.98E-07
24 Hr
Anneal
60
-3.23E-07
-3.56E-07
-3.64E-07
-3.73E-07
-3.61E-07
-3.58E-07
-3.47E-07
-3.38E-07
-3.48E-07
-3.40E-07
-2.93E-07
-3.03E-07
168 Hr
Anneal
70
-3.10E-07
-3.35E-07
-3.48E-07
-3.54E-07
-3.45E-07
-3.40E-07
-3.30E-07
-3.25E-07
-3.30E-07
-3.27E-07
-2.92E-07
-3.01E-07
-3.14E-07 -3.26E-07 -3.36E-07 -3.40E-07 -3.55E-07 -3.56E-07 -3.38E-07
1.57E-08 1.83E-08 2.00E-08 1.90E-08 1.85E-08 1.91E-08 1.73E-08
-2.71E-07 -2.76E-07 -2.81E-07 -2.88E-07 -3.04E-07 -3.03E-07 -2.91E-07
-3.57E-07 -3.76E-07 -3.90E-07 -3.92E-07 -4.06E-07 -4.08E-07 -3.86E-07
-3.12E-07
6.86E-09
-2.93E-07
-3.30E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.15E-07
6.87E-09
-2.97E-07
-3.34E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.22E-07
6.70E-09
-3.04E-07
-3.40E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.29E-07
6.58E-09
-3.11E-07
-3.47E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.47E-07
8.20E-09
-3.24E-07
-3.69E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
34
-3.46E-07
7.86E-09
-3.25E-07
-3.68E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.30E-07
5.77E-09
-3.15E-07
-3.46E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS1 2 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.12. Plot of +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
35
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.12. Raw data for +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS1 2 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.77E-07
-3.33E-07
-3.17E-07
-3.18E-07
-2.98E-07
-3.16E-07
-3.07E-07
-2.97E-07
-3.01E-07
-3.00E-07
-3.11E-07
-3.10E-07
10
-2.86E-07
-3.49E-07
-3.30E-07
-3.30E-07
-3.11E-07
-3.20E-07
-3.13E-07
-3.02E-07
-3.03E-07
-3.04E-07
-3.10E-07
-3.14E-07
Total Dose (krad(Si))
20
30
-2.93E-07 -2.99E-07
-3.55E-07 -3.60E-07
-3.38E-07 -3.41E-07
-3.38E-07 -3.45E-07
-3.19E-07 -3.24E-07
-3.27E-07 -3.33E-07
-3.20E-07 -3.25E-07
-3.08E-07 -3.16E-07
-3.10E-07 -3.17E-07
-3.10E-07 -3.17E-07
-3.11E-07 -3.11E-07
-3.09E-07 -3.13E-07
50
-3.14E-07
-3.74E-07
-3.60E-07
-3.59E-07
-3.38E-07
-3.54E-07
-3.40E-07
-3.31E-07
-3.31E-07
-3.35E-07
-3.15E-07
-3.12E-07
24 Hr
Anneal
60
-3.14E-07
-3.74E-07
-3.60E-07
-3.60E-07
-3.37E-07
-3.52E-07
-3.45E-07
-3.32E-07
-3.30E-07
-3.34E-07
-3.17E-07
-3.16E-07
168 Hr
Anneal
70
-3.00E-07
-3.58E-07
-3.39E-07
-3.40E-07
-3.21E-07
-3.35E-07
-3.28E-07
-3.17E-07
-3.19E-07
-3.20E-07
-3.16E-07
-3.15E-07
-3.09E-07 -3.21E-07 -3.29E-07 -3.34E-07 -3.49E-07 -3.49E-07 -3.32E-07
2.15E-08 2.37E-08 2.37E-08 2.35E-08 2.33E-08 2.35E-08 2.18E-08
-2.50E-07 -2.56E-07 -2.64E-07 -2.69E-07 -2.85E-07 -2.85E-07 -2.72E-07
-3.68E-07 -3.86E-07 -3.94E-07 -3.98E-07 -4.13E-07 -4.14E-07 -3.91E-07
-3.04E-07
7.39E-09
-2.84E-07
-3.25E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.08E-07
7.87E-09
-2.87E-07
-3.30E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.15E-07
8.01E-09
-2.93E-07
-3.37E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.22E-07
7.60E-09
-3.01E-07
-3.42E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.38E-07
9.47E-09
-3.12E-07
-3.64E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
36
-3.39E-07
9.50E-09
-3.13E-07
-3.65E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.24E-07
7.47E-09
-3.03E-07
-3.44E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS1 3 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.13. Plot of +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
37
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.13. Raw data for +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS1 3 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.77E-07
-3.26E-07
-3.18E-07
-3.13E-07
-2.98E-07
-3.13E-07
-3.06E-07
-2.96E-07
-2.94E-07
-3.00E-07
-3.10E-07
-3.19E-07
10
-2.85E-07
-3.37E-07
-3.30E-07
-3.24E-07
-3.10E-07
-3.16E-07
-3.10E-07
-3.00E-07
-2.95E-07
-3.03E-07
-3.08E-07
-3.21E-07
Total Dose (krad(Si))
20
30
-2.92E-07 -2.98E-07
-3.47E-07 -3.53E-07
-3.39E-07 -3.45E-07
-3.33E-07 -3.37E-07
-3.18E-07 -3.23E-07
-3.22E-07 -3.30E-07
-3.17E-07 -3.22E-07
-3.06E-07 -3.13E-07
-3.02E-07 -3.09E-07
-3.09E-07 -3.16E-07
-3.10E-07 -3.10E-07
-3.16E-07 -3.21E-07
50
-3.12E-07
-3.66E-07
-3.61E-07
-3.54E-07
-3.37E-07
-3.50E-07
-3.36E-07
-3.28E-07
-3.24E-07
-3.32E-07
-3.13E-07
-3.20E-07
24 Hr
Anneal
60
-3.12E-07
-3.68E-07
-3.60E-07
-3.56E-07
-3.37E-07
-3.48E-07
-3.37E-07
-3.28E-07
-3.23E-07
-3.31E-07
-3.15E-07
-3.24E-07
168 Hr
Anneal
70
-2.99E-07
-3.50E-07
-3.44E-07
-3.35E-07
-3.21E-07
-3.32E-07
-3.24E-07
-3.15E-07
-3.11E-07
-3.18E-07
-3.14E-07
-3.23E-07
-3.06E-07 -3.17E-07 -3.26E-07 -3.31E-07 -3.46E-07 -3.47E-07 -3.30E-07
1.94E-08 2.06E-08 2.16E-08 2.18E-08 2.18E-08 2.24E-08 2.04E-08
-2.53E-07 -2.61E-07 -2.66E-07 -2.72E-07 -2.86E-07 -2.85E-07 -2.74E-07
-3.60E-07 -3.74E-07 -3.85E-07 -3.91E-07 -4.06E-07 -4.08E-07 -3.86E-07
-3.02E-07
7.63E-09
-2.81E-07
-3.22E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.05E-07
8.33E-09
-2.82E-07
-3.27E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.11E-07
8.26E-09
-2.88E-07
-3.34E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.18E-07
8.09E-09
-2.96E-07
-3.40E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.34E-07
9.94E-09
-3.07E-07
-3.61E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
38
-3.34E-07
9.68E-09
-3.07E-07
-3.60E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.20E-07
7.98E-09
-2.98E-07
-3.42E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS1 4 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.14. Plot of +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
39
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.14. Raw data for +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS1 4 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.91E-07
-3.12E-07
-3.12E-07
-3.29E-07
-3.19E-07
-3.18E-07
-3.05E-07
-3.10E-07
-3.15E-07
-3.10E-07
-2.81E-07
-2.97E-07
10
-2.99E-07
-3.24E-07
-3.25E-07
-3.40E-07
-3.32E-07
-3.22E-07
-3.10E-07
-3.14E-07
-3.16E-07
-3.13E-07
-2.80E-07
-3.00E-07
Total Dose (krad(Si))
20
30
-3.07E-07 -3.13E-07
-3.32E-07 -3.36E-07
-3.34E-07 -3.36E-07
-3.53E-07 -3.57E-07
-3.45E-07 -3.49E-07
-3.28E-07 -3.34E-07
-3.17E-07 -3.23E-07
-3.21E-07 -3.28E-07
-3.24E-07 -3.30E-07
-3.19E-07 -3.26E-07
-2.80E-07 -2.81E-07
-2.95E-07 -2.99E-07
50
-3.28E-07
-3.53E-07
-3.54E-07
-3.69E-07
-3.63E-07
-3.52E-07
-3.38E-07
-3.50E-07
-3.49E-07
-3.46E-07
-2.83E-07
-2.98E-07
24 Hr
Anneal
60
-3.28E-07
-3.55E-07
-3.54E-07
-3.71E-07
-3.62E-07
-3.52E-07
-3.40E-07
-3.50E-07
-3.49E-07
-3.46E-07
-2.85E-07
-3.02E-07
168 Hr
Anneal
70
-3.13E-07
-3.34E-07
-3.34E-07
-3.54E-07
-3.48E-07
-3.35E-07
-3.25E-07
-3.31E-07
-3.32E-07
-3.28E-07
-2.84E-07
-3.01E-07
-3.12E-07 -3.24E-07 -3.34E-07 -3.38E-07 -3.53E-07 -3.54E-07 -3.37E-07
1.40E-08 1.53E-08 1.77E-08 1.70E-08 1.58E-08 1.61E-08 1.58E-08
-2.74E-07 -2.82E-07 -2.86E-07 -2.92E-07 -3.10E-07 -3.10E-07 -2.93E-07
-3.51E-07 -3.66E-07 -3.83E-07 -3.85E-07 -3.97E-07 -3.98E-07 -3.80E-07
-3.12E-07
4.87E-09
-2.98E-07
-3.25E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.15E-07
4.30E-09
-3.03E-07
-3.27E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.22E-07
4.11E-09
-3.10E-07
-3.33E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.28E-07
4.03E-09
-3.17E-07
-3.39E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.47E-07
5.31E-09
-3.32E-07
-3.62E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
40
-3.47E-07
5.06E-09
-3.34E-07
-3.61E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.30E-07
3.61E-09
-3.20E-07
-3.40E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS1 1 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.15. Plot of -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
41
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.15. Raw data for -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS1 1 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.91E-07
-3.08E-07
-3.20E-07
-3.36E-07
-3.18E-07
-3.22E-07
-3.03E-07
-3.06E-07
-3.09E-07
-3.13E-07
-2.80E-07
-2.98E-07
10
-2.99E-07
-3.20E-07
-3.32E-07
-3.51E-07
-3.31E-07
-3.25E-07
-3.08E-07
-3.10E-07
-3.11E-07
-3.17E-07
-2.78E-07
-3.00E-07
Total Dose (krad(Si))
20
30
-3.05E-07 -3.10E-07
-3.27E-07 -3.31E-07
-3.39E-07 -3.41E-07
-3.60E-07 -3.62E-07
-3.39E-07 -3.45E-07
-3.32E-07 -3.39E-07
-3.15E-07 -3.20E-07
-3.17E-07 -3.24E-07
-3.18E-07 -3.25E-07
-3.22E-07 -3.29E-07
-2.79E-07 -2.79E-07
-2.95E-07 -2.99E-07
50
-3.23E-07
-3.47E-07
-3.58E-07
-3.75E-07
-3.60E-07
-3.57E-07
-3.35E-07
-3.40E-07
-3.40E-07
-3.49E-07
-2.82E-07
-2.98E-07
24 Hr
Anneal
60
-3.22E-07
-3.47E-07
-3.58E-07
-3.76E-07
-3.57E-07
-3.56E-07
-3.35E-07
-3.38E-07
-3.39E-07
-3.48E-07
-2.83E-07
-3.02E-07
168 Hr
Anneal
70
-3.10E-07
-3.28E-07
-3.39E-07
-3.59E-07
-3.39E-07
-3.39E-07
-3.23E-07
-3.26E-07
-3.27E-07
-3.31E-07
-2.82E-07
-3.00E-07
-3.14E-07 -3.26E-07 -3.34E-07 -3.38E-07 -3.53E-07 -3.52E-07 -3.35E-07
1.65E-08 1.91E-08 2.02E-08 1.92E-08 1.93E-08 1.97E-08 1.77E-08
-2.69E-07 -2.74E-07 -2.78E-07 -2.85E-07 -3.00E-07 -2.98E-07 -2.86E-07
-3.60E-07 -3.79E-07 -3.89E-07 -3.90E-07 -4.06E-07 -4.06E-07 -3.84E-07
-3.11E-07
7.27E-09
-2.91E-07
-3.31E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.14E-07
7.06E-09
-2.95E-07
-3.34E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.21E-07
6.84E-09
-3.02E-07
-3.40E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.27E-07
7.15E-09
-3.08E-07
-3.47E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.44E-07
8.88E-09
-3.20E-07
-3.68E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
42
-3.43E-07
8.70E-09
-3.19E-07
-3.67E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.29E-07
6.29E-09
-3.12E-07
-3.46E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS1 2 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.16. Plot of -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
43
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.16. Raw data for -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS1 2 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.80E-07
-3.30E-07
-3.14E-07
-3.17E-07
-3.00E-07
-3.13E-07
-3.06E-07
-2.98E-07
-3.01E-07
-2.97E-07
-3.14E-07
-3.12E-07
10
-2.88E-07
-3.41E-07
-3.26E-07
-3.29E-07
-3.14E-07
-3.17E-07
-3.11E-07
-3.02E-07
-3.03E-07
-3.01E-07
-3.12E-07
-3.14E-07
Total Dose (krad(Si))
20
30
-2.95E-07 -3.01E-07
-3.52E-07 -3.55E-07
-3.33E-07 -3.35E-07
-3.37E-07 -3.41E-07
-3.22E-07 -3.26E-07
-3.23E-07 -3.30E-07
-3.18E-07 -3.24E-07
-3.09E-07 -3.16E-07
-3.09E-07 -3.15E-07
-3.07E-07 -3.14E-07
-3.13E-07 -3.13E-07
-3.09E-07 -3.13E-07
50
-3.14E-07
-3.68E-07
-3.53E-07
-3.55E-07
-3.40E-07
-3.49E-07
-3.37E-07
-3.33E-07
-3.30E-07
-3.31E-07
-3.16E-07
-3.12E-07
24 Hr
Anneal
60
-3.14E-07
-3.68E-07
-3.53E-07
-3.58E-07
-3.39E-07
-3.49E-07
-3.38E-07
-3.32E-07
-3.29E-07
-3.30E-07
-3.17E-07
-3.16E-07
168 Hr
Anneal
70
-3.01E-07
-3.53E-07
-3.34E-07
-3.37E-07
-3.22E-07
-3.31E-07
-3.25E-07
-3.18E-07
-3.18E-07
-3.16E-07
-3.16E-07
-3.14E-07
-3.08E-07 -3.20E-07 -3.28E-07 -3.32E-07 -3.46E-07 -3.46E-07 -3.29E-07
1.92E-08 2.00E-08 2.12E-08 2.02E-08 2.05E-08 2.10E-08 1.93E-08
-2.56E-07 -2.65E-07 -2.70E-07 -2.76E-07 -2.90E-07 -2.89E-07 -2.76E-07
-3.61E-07 -3.74E-07 -3.86E-07 -3.87E-07 -4.02E-07 -4.04E-07 -3.82E-07
-3.03E-07
6.45E-09
-2.85E-07
-3.21E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.07E-07
6.86E-09
-2.88E-07
-3.25E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.13E-07
7.01E-09
-2.94E-07
-3.32E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.20E-07
6.72E-09
-3.01E-07
-3.38E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.36E-07
7.80E-09
-3.15E-07
-3.57E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
44
-3.36E-07
8.20E-09
-3.13E-07
-3.58E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.22E-07
6.17E-09
-3.05E-07
-3.38E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS1 3 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.17. Plot of -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
45
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.17. Raw data for -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS1 3 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.78E-07
-3.27E-07
-3.18E-07
-3.20E-07
-2.95E-07
-3.17E-07
-3.03E-07
-2.97E-07
-2.98E-07
-2.96E-07
-3.12E-07
-3.14E-07
10
-2.86E-07
-3.39E-07
-3.31E-07
-3.31E-07
-3.07E-07
-3.20E-07
-3.08E-07
-3.01E-07
-3.00E-07
-3.00E-07
-3.10E-07
-3.16E-07
Total Dose (krad(Si))
20
30
-2.92E-07 -2.96E-07
-3.48E-07 -3.53E-07
-3.38E-07 -3.40E-07
-3.39E-07 -3.46E-07
-3.14E-07 -3.18E-07
-3.27E-07 -3.34E-07
-3.14E-07 -3.20E-07
-3.07E-07 -3.13E-07
-3.07E-07 -3.13E-07
-3.05E-07 -3.12E-07
-3.11E-07 -3.11E-07
-3.11E-07 -3.14E-07
50
-3.10E-07
-3.65E-07
-3.57E-07
-3.58E-07
-3.30E-07
-3.52E-07
-3.33E-07
-3.28E-07
-3.28E-07
-3.28E-07
-3.14E-07
-3.14E-07
24 Hr
Anneal
60
-3.09E-07
-3.64E-07
-3.58E-07
-3.61E-07
-3.30E-07
-3.51E-07
-3.34E-07
-3.27E-07
-3.27E-07
-3.27E-07
-3.15E-07
-3.18E-07
168 Hr
Anneal
70
-2.97E-07
-3.51E-07
-3.38E-07
-3.40E-07
-3.16E-07
-3.35E-07
-3.22E-07
-3.15E-07
-3.15E-07
-3.15E-07
-3.14E-07
-3.16E-07
-3.08E-07 -3.19E-07 -3.26E-07 -3.31E-07 -3.44E-07 -3.45E-07 -3.28E-07
2.07E-08 2.21E-08 2.30E-08 2.34E-08 2.31E-08 2.41E-08 2.15E-08
-2.51E-07 -2.58E-07 -2.63E-07 -2.66E-07 -2.81E-07 -2.79E-07 -2.69E-07
-3.64E-07 -3.79E-07 -3.89E-07 -3.95E-07 -4.08E-07 -4.11E-07 -3.87E-07
-3.02E-07
8.50E-09
-2.79E-07
-3.25E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.06E-07
8.88E-09
-2.81E-07
-3.30E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.12E-07
8.94E-09
-2.88E-07
-3.37E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.18E-07
9.10E-09
-2.93E-07
-3.43E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.34E-07
1.06E-08
-3.05E-07
-3.63E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
46
-3.33E-07
1.05E-08
-3.04E-07
-3.62E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.20E-07
8.58E-09
-2.97E-07
-3.44E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS1 4 15V (A)
@ VS=+/-15V, VCM=0V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.18. Plot of -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
47
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.18. Raw data for -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS1 4 15V (A)
@ VS=+/-15V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.87E-07
-3.05E-07
-3.19E-07
-3.30E-07
-3.11E-07
-3.16E-07
-3.07E-07
-3.05E-07
-3.18E-07
-3.07E-07
-2.78E-07
-2.90E-07
10
-2.95E-07
-3.16E-07
-3.32E-07
-3.40E-07
-3.24E-07
-3.19E-07
-3.11E-07
-3.10E-07
-3.20E-07
-3.10E-07
-2.77E-07
-2.91E-07
Total Dose (krad(Si))
20
30
-3.02E-07 -3.07E-07
-3.23E-07 -3.27E-07
-3.38E-07 -3.40E-07
-3.54E-07 -3.56E-07
-3.32E-07 -3.36E-07
-3.25E-07 -3.31E-07
-3.18E-07 -3.25E-07
-3.16E-07 -3.23E-07
-3.27E-07 -3.34E-07
-3.16E-07 -3.23E-07
-2.78E-07 -2.78E-07
-2.87E-07 -2.90E-07
50
-3.22E-07
-3.41E-07
-3.58E-07
-3.68E-07
-3.55E-07
-3.48E-07
-3.40E-07
-3.39E-07
-3.53E-07
-3.38E-07
-2.80E-07
-2.90E-07
24 Hr
Anneal
60
-3.21E-07
-3.40E-07
-3.58E-07
-3.69E-07
-3.52E-07
-3.48E-07
-3.40E-07
-3.39E-07
-3.53E-07
-3.37E-07
-2.82E-07
-2.94E-07
168 Hr
Anneal
70
-3.08E-07
-3.24E-07
-3.39E-07
-3.52E-07
-3.32E-07
-3.32E-07
-3.26E-07
-3.26E-07
-3.36E-07
-3.24E-07
-2.81E-07
-2.92E-07
-3.10E-07 -3.22E-07 -3.30E-07 -3.33E-07 -3.49E-07 -3.48E-07 -3.31E-07
1.60E-08 1.72E-08 1.92E-08 1.81E-08 1.79E-08 1.83E-08 1.64E-08
-2.66E-07 -2.74E-07 -2.77E-07 -2.84E-07 -3.00E-07 -2.98E-07 -2.86E-07
-3.54E-07 -3.69E-07 -3.83E-07 -3.83E-07 -3.98E-07 -3.98E-07 -3.76E-07
-3.11E-07
5.96E-09
-2.94E-07
-3.27E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.14E-07
5.27E-09
-3.00E-07
-3.29E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.20E-07
5.51E-09
-3.05E-07
-3.36E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.27E-07
5.25E-09
-3.13E-07
-3.41E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.44E-07
6.59E-09
-3.26E-07
-3.62E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
48
-3.43E-07
6.77E-09
-3.25E-07
-3.62E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.29E-07
4.96E-09
-3.15E-07
-3.42E-07
-8.65E-07
PASS
8.65E-07
PASS
Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.19. Plot of Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
49
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.19. Raw data for Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage2 1 15V (V)
@ VS=+/-15V, VCM=15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
8.45E-05
-1.02E-05
2.28E-04
3.57E-05
1.80E-04
1.58E-04
-7.94E-05
4.02E-04
-5.96E-05
8.84E-05
-2.62E-04
2.31E-04
Total Dose (krad(Si))
20
30
6.92E-05 6.52E-05
-1.98E-05 -2.22E-05
2.18E-04 2.20E-04
1.92E-05 1.88E-05
1.73E-04 1.75E-04
1.49E-04 1.48E-04
-8.16E-05 -8.24E-05
3.93E-04 3.92E-04
-6.30E-05 -6.50E-05
8.30E-05 8.14E-05
-2.58E-04 -2.57E-04
2.37E-04 2.34E-04
10
7.25E-05
-1.72E-05
2.19E-04
2.40E-05
1.70E-04
1.49E-04
-8.51E-05
3.93E-04
-6.44E-05
8.07E-05
-2.59E-04
2.33E-04
50
5.48E-05
-2.48E-05
2.16E-04
1.87E-05
1.72E-04
1.44E-04
-8.00E-05
3.92E-04
-6.44E-05
7.88E-05
-2.58E-04
2.36E-04
24 Hr
Anneal
60
5.85E-05
-2.29E-05
2.16E-04
2.13E-05
1.74E-04
1.46E-04
-7.93E-05
3.94E-04
-6.33E-05
7.90E-05
-2.58E-04
2.32E-04
168 Hr
Anneal
70
6.01E-05
-3.12E-05
2.14E-04
1.61E-05
1.68E-04
1.37E-04
-8.25E-05
3.82E-04
-7.11E-05
8.18E-05
-2.56E-04
2.34E-04
1.04E-04 9.38E-05 9.20E-05 9.13E-05 8.73E-05 8.92E-05 8.55E-05
9.90E-05 9.90E-05 1.01E-04 1.03E-04 1.03E-04 1.01E-04 1.03E-04
3.75E-04 3.65E-04 3.69E-04 3.73E-04 3.69E-04 3.67E-04 3.68E-04
-1.68E-04 -1.78E-04 -1.85E-04 -1.91E-04 -1.94E-04 -1.89E-04 -1.97E-04
1.02E-04
1.95E-04
6.37E-04
-4.33E-04
-8.00E-04
PASS
8.00E-04
PASS
9.46E-05
1.94E-04
6.25E-04
-4.36E-04
-9.50E-04
PASS
9.50E-04
PASS
9.62E-05
1.92E-04
6.24E-04
-4.32E-04
-9.50E-04
PASS
9.50E-04
PASS
9.48E-05
1.93E-04
6.23E-04
-4.33E-04
-9.50E-04
PASS
9.50E-04
PASS
9.42E-05
1.92E-04
6.20E-04
-4.31E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
50
9.52E-05
1.92E-04
6.22E-04
-4.31E-04
-9.50E-04
PASS
9.50E-04
PASS
8.95E-05
1.89E-04
6.09E-04
-4.29E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.20. Plot of Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
51
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.20. Raw data for Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage2 2 15V (V)
@ VS=+/-15V, VCM=15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
24 Hr
168 Hr
Anneal
Anneal
Total Dose (krad(Si))
20
30
50
60
70
4.67E-05 4.63E-05 4.26E-05 4.41E-05 4.35E-05
-9.88E-05 -1.01E-04 -1.02E-04 -9.74E-05 -1.01E-04
1.46E-04 1.45E-04 1.40E-04 1.43E-04 1.44E-04
7.61E-05 7.66E-05 7.34E-05 7.39E-05 7.99E-05
3.30E-04 3.29E-04 3.26E-04 3.29E-04 3.22E-04
-3.71E-05 -3.73E-05 -3.52E-05 -3.21E-05 -3.73E-05
8.70E-05 8.92E-05 8.86E-05 9.41E-05 7.95E-05
2.32E-04 2.30E-04 2.26E-04 2.30E-04 2.23E-04
1.03E-04 1.03E-04 1.08E-04 1.07E-04 9.89E-05
-1.02E-04 -1.03E-04 -1.03E-04 -1.00E-04 -1.01E-04
8.82E-05 9.00E-05 8.89E-05 9.07E-05 9.12E-05
3.19E-04 3.16E-04 3.21E-04 3.14E-04 3.18E-04
0
10
5.94E-05 4.88E-05
-9.16E-05 -9.82E-05
1.51E-04 1.44E-04
8.41E-05 7.84E-05
3.38E-04 3.34E-04
-3.28E-05 -3.76E-05
8.96E-05 8.69E-05
2.47E-04 2.35E-04
1.03E-04 1.00E-04
-1.02E-04 -1.03E-04
8.57E-05 8.83E-05
3.15E-04 3.17E-04
1.08E-04 1.01E-04 9.98E-05 9.92E-05 9.61E-05 9.86E-05 9.75E-05
1.56E-04 1.57E-04 1.56E-04 1.57E-04 1.56E-04 1.56E-04 1.54E-04
5.37E-04 5.32E-04 5.28E-04 5.29E-04 5.24E-04 5.26E-04 5.21E-04
-3.20E-04 -3.30E-04 -3.29E-04 -3.31E-04 -3.32E-04 -3.29E-04 -3.26E-04
6.11E-05
1.35E-04
4.30E-04
-3.08E-04
-8.00E-04
PASS
8.00E-04
PASS
5.63E-05
1.31E-04
4.16E-04
-3.03E-04
-9.50E-04
PASS
9.50E-04
PASS
5.66E-05
1.30E-04
4.14E-04
-3.01E-04
-9.50E-04
PASS
9.50E-04
PASS
5.64E-05
1.30E-04
4.13E-04
-3.01E-04
-9.50E-04
PASS
9.50E-04
PASS
5.69E-05
1.29E-04
4.10E-04
-2.96E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
52
5.98E-05
1.29E-04
4.13E-04
-2.93E-04
-9.50E-04
PASS
9.50E-04
PASS
5.27E-05
1.26E-04
3.98E-04
-2.93E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.21. Plot of Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
53
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.21. Raw data for Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage2 3 15V (V)
@ VS=+/-15V, VCM=15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
24 Hr
168 Hr
Anneal
Anneal
Total Dose (krad(Si))
20
30
50
60
70
5.31E-04 5.27E-04 5.23E-04 5.23E-04 5.17E-04
1.59E-04 1.57E-04 1.56E-04 1.59E-04 1.61E-04
2.04E-04 2.05E-04 2.00E-04 2.00E-04 1.92E-04
1.86E-04 1.85E-04 1.81E-04 1.82E-04 1.75E-04
-2.18E-05 -2.46E-05 -2.72E-05 -2.71E-05 -2.68E-05
1.56E-04 1.55E-04 1.51E-04 1.52E-04 1.40E-04
9.11E-05 9.07E-05 8.65E-05 8.80E-05 9.27E-05
2.23E-04 2.21E-04 2.19E-04 2.20E-04 2.07E-04
1.63E-04 1.63E-04 1.60E-04 1.62E-04 1.64E-04
6.07E-05 5.76E-05 5.78E-05 5.95E-05 6.36E-05
4.04E-04 4.05E-04 4.06E-04 4.04E-04 4.05E-04
1.81E-04 1.81E-04 1.85E-04 1.79E-04 1.81E-04
0
10
5.47E-04 5.35E-04
1.68E-04 1.60E-04
2.16E-04 2.09E-04
2.00E-04 1.92E-04
-1.24E-05 -1.75E-05
1.64E-04 1.57E-04
9.88E-05 9.07E-05
2.33E-04 2.27E-04
1.68E-04 1.64E-04
6.46E-05 6.10E-05
3.99E-04 4.03E-04
1.79E-04 1.82E-04
2.24E-04 2.16E-04 2.12E-04 2.10E-04 2.07E-04 2.07E-04 2.04E-04
2.02E-04 2.00E-04 2.00E-04 1.99E-04 1.99E-04 1.98E-04 1.96E-04
7.79E-04 7.64E-04 7.61E-04 7.57E-04 7.52E-04 7.51E-04 7.42E-04
-3.31E-04 -3.33E-04 -3.37E-04 -3.37E-04 -3.39E-04 -3.37E-04 -3.34E-04
1.46E-04
6.57E-05
3.26E-04
-3.44E-05
-8.00E-04
PASS
8.00E-04
PASS
1.40E-04
6.52E-05
3.19E-04
-3.91E-05
-9.50E-04
PASS
9.50E-04
PASS
1.39E-04
6.38E-05
3.14E-04
-3.63E-05
-9.50E-04
PASS
9.50E-04
PASS
1.37E-04
6.42E-05
3.13E-04
-3.86E-05
-9.50E-04
PASS
9.50E-04
PASS
1.35E-04
6.38E-05
3.10E-04
-3.99E-05
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
54
1.36E-04
6.36E-05
3.11E-04
-3.81E-05
-9.50E-04
PASS
9.50E-04
PASS
1.34E-04
5.70E-05
2.90E-04
-2.26E-05
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.22. Plot of Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
55
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.22. Raw data for Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage2 4 15V (V)
@ VS=+/-15V, VCM=15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
24 Hr
168 Hr
Anneal
Anneal
Total Dose (krad(Si))
20
30
50
60
70
-2.17E-04 -2.19E-04 -2.22E-04 -2.20E-04 -2.14E-04
1.05E-04 1.05E-04 1.01E-04 1.02E-04 1.06E-04
1.08E-04 1.09E-04 1.05E-04 1.04E-04 9.29E-05
1.05E-04 1.05E-04 1.04E-04 1.05E-04 9.81E-05
-2.05E-04 -2.08E-04 -2.06E-04 -2.04E-04 -2.14E-04
1.17E-04 1.22E-04 1.29E-04 1.28E-04 1.26E-04
3.03E-04 3.04E-04 3.05E-04 3.05E-04 2.95E-04
9.04E-05 9.28E-05 9.34E-05 9.63E-05 9.43E-05
1.26E-04 1.28E-04 1.31E-04 1.30E-04 1.25E-04
3.16E-05 3.17E-05 3.13E-05 3.51E-05 3.31E-05
3.10E-04 3.11E-04 3.09E-04 3.07E-04 3.09E-04
1.50E-05 1.33E-05 1.62E-05 1.33E-05 1.26E-05
0
10
-2.06E-04 -2.15E-04
1.16E-04 1.07E-04
1.17E-04 1.09E-04
1.11E-04 1.05E-04
-1.95E-04 -2.03E-04
1.22E-04 1.16E-04
3.10E-04 3.01E-04
9.69E-05 9.05E-05
1.29E-04 1.23E-04
3.59E-05 2.94E-05
3.07E-04 3.10E-04
4.52E-06 1.31E-05
-1.14E-05 -1.93E-05 -2.06E-05 -2.16E-05 -2.37E-05 -2.25E-05 -2.64E-05
1.73E-04 1.73E-04 1.74E-04 1.75E-04 1.74E-04 1.73E-04 1.72E-04
4.62E-04 4.55E-04 4.56E-04 4.58E-04 4.54E-04 4.52E-04 4.45E-04
-4.85E-04 -4.94E-04 -4.97E-04 -5.02E-04 -5.01E-04 -4.97E-04 -4.97E-04
1.39E-04
1.03E-04
4.20E-04
-1.42E-04
-8.00E-04
PASS
8.00E-04
PASS
1.32E-04
1.01E-04
4.10E-04
-1.46E-04
-9.50E-04
PASS
9.50E-04
PASS
1.34E-04
1.02E-04
4.12E-04
-1.45E-04
-9.50E-04
PASS
9.50E-04
PASS
1.36E-04
1.02E-04
4.15E-04
-1.43E-04
-9.50E-04
PASS
9.50E-04
PASS
1.38E-04
1.02E-04
4.17E-04
-1.41E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
56
1.39E-04
1.00E-04
4.14E-04
-1.37E-04
-9.50E-04
PASS
9.50E-04
PASS
1.35E-04
9.71E-05
4.01E-04
-1.32E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.23. Plot of Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
57
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.23. Raw data for Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current2 1 15V (A)
@ VS=+/-15V, VCM=15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-9.12E-09
-8.70E-10
-3.13E-09
-2.00E-09
1.15E-08
-1.01E-09
1.09E-08
-1.13E-09
-1.50E-09
1.07E-08
-9.30E-10
9.40E-10
10
-1.07E-08
-2.82E-09
-4.97E-09
-4.40E-09
9.29E-09
1.00E-11
1.27E-08
1.00E-09
-9.00E-10
1.18E-08
2.21E-09
5.93E-09
Total Dose
20
-1.32E-08
-5.42E-09
-7.58E-09
-6.62E-09
7.28E-09
5.80E-10
1.40E-08
1.82E-09
1.50E-10
1.22E-08
3.53E-09
7.11E-09
(krad(Si))
30
-1.53E-08
-7.14E-09
-7.61E-09
-7.69E-09
7.31E-09
8.10E-10
1.47E-08
2.60E-09
1.14E-09
1.32E-08
4.59E-09
7.05E-09
50
-2.14E-08
-9.86E-09
-8.84E-09
-1.01E-08
3.48E-09
6.30E-10
1.60E-08
3.62E-09
3.06E-09
1.41E-08
4.98E-09
6.80E-09
24 Hr
Anneal
60
-1.85E-08
-7.84E-09
-7.38E-09
-7.78E-09
6.56E-09
2.71E-09
1.77E-08
4.74E-09
3.83E-09
1.49E-08
5.70E-09
6.54E-09
168 Hr
Anneal
70
-1.84E-08
-9.04E-09
-9.07E-09
-8.97E-09
4.93E-09
1.30E-10
1.36E-08
2.88E-09
3.00E-10
1.32E-08
6.64E-09
7.25E-09
-7.22E-10 -2.72E-09 -5.10E-09 -6.09E-09 -9.34E-09 -6.99E-09 -8.10E-09
7.54E-09 7.34E-09 7.53E-09 8.23E-09 8.81E-09 8.91E-09 8.33E-09
2.00E-08 1.74E-08 1.55E-08 1.65E-08 1.48E-08 1.74E-08 1.47E-08
-2.14E-08 -2.28E-08 -2.57E-08 -2.87E-08 -3.35E-08 -3.14E-08 -3.10E-08
3.58E-09
6.57E-09
2.16E-08
-1.44E-08
-7.00E-08
PASS
7.00E-08
PASS
4.92E-09
6.73E-09
2.34E-08
-1.35E-08
-1.00E-07
PASS
1.00E-07
PASS
5.73E-09
6.75E-09
2.42E-08
-1.28E-08
-1.00E-07
PASS
1.00E-07
PASS
6.49E-09
6.86E-09
2.53E-08
-1.23E-08
-1.00E-07
PASS
1.00E-07
PASS
7.47E-09
7.02E-09
2.67E-08
-1.18E-08
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
58
8.78E-09
6.99E-09
2.79E-08
-1.04E-08
-1.00E-07
PASS
1.00E-07
PASS
6.02E-09
6.82E-09
2.47E-08
-1.27E-08
-1.00E-07
PASS
1.00E-07
PASS
Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.24. Plot of Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
59
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.24. Raw data for Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current2 2 15V (A)
@ VS=+/-15V, VCM=15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
10
5.23E-09 3.90E-09
1.74E-09 9.70E-10
3.31E-09 1.41E-09
1.21E-08 8.96E-09
2.92E-09 7.00E-11
-2.03E-09 -1.37E-09
5.25E-09 6.27E-09
2.56E-09 4.23E-09
4.86E-09 6.18E-09
1.57E-08 1.69E-08
2.64E-09 4.85E-09
1.36E-08 1.90E-08
Total Dose
20
2.02E-09
-6.10E-10
1.50E-10
6.96E-09
-2.12E-09
-9.90E-10
6.43E-09
4.49E-09
7.22E-09
1.75E-08
6.33E-09
1.92E-08
(krad(Si))
30
2.70E-10
-2.27E-09
-8.40E-10
6.48E-09
-3.41E-09
-9.70E-10
7.18E-09
4.43E-09
8.52E-09
1.78E-08
7.25E-09
1.91E-08
50
-2.00E-09
-4.10E-09
-2.74E-09
4.85E-09
-6.04E-09
-3.80E-10
5.92E-09
4.19E-09
9.19E-09
1.72E-08
7.59E-09
1.94E-08
24 Hr
Anneal
60
-4.20E-10
-2.14E-09
-3.90E-10
6.56E-09
-2.93E-09
1.52E-09
8.17E-09
6.48E-09
1.05E-08
1.93E-08
8.17E-09
1.95E-08
168 Hr
Anneal
70
-1.44E-09
-4.15E-09
-1.91E-09
4.19E-09
-5.05E-09
-1.31E-09
6.18E-09
2.45E-09
7.08E-09
1.72E-08
9.35E-09
1.99E-08
5.06E-09 3.06E-09 1.28E-09 4.60E-11 -2.01E-09 1.36E-10 -1.67E-09
4.14E-09 3.59E-09 3.51E-09 3.86E-09 4.13E-09 3.76E-09 3.61E-09
1.64E-08 1.29E-08 1.09E-08 1.06E-08 9.32E-09 1.04E-08 8.22E-09
-6.28E-09 -6.78E-09 -8.34E-09 -1.05E-08 -1.33E-08 -1.02E-08 -1.16E-08
5.26E-09
6.50E-09
2.31E-08
-1.26E-08
-7.00E-08
PASS
7.00E-08
PASS
6.44E-09
6.62E-09
2.46E-08
-1.17E-08
-1.00E-07
PASS
1.00E-07
PASS
6.93E-09
6.72E-09
2.53E-08
-1.15E-08
-1.00E-07
PASS
1.00E-07
PASS
7.40E-09
6.87E-09
2.62E-08
-1.14E-08
-1.00E-07
PASS
1.00E-07
PASS
7.22E-09
6.56E-09
2.52E-08
-1.08E-08
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
60
9.19E-09
6.53E-09
2.71E-08
-8.71E-09
-1.00E-07
PASS
1.00E-07
PASS
6.32E-09
6.92E-09
2.53E-08
-1.27E-08
-1.00E-07
PASS
1.00E-07
PASS
Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.25. Plot of Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
61
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.25. Raw data for Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current2 3 15V (A)
@ VS=+/-15V, VCM=15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
10
1.10E-08 1.01E-08
5.99E-09 4.21E-09
2.42E-09 -5.60E-10
4.05E-09 4.90E-10
1.33E-08 9.15E-09
7.69E-09 8.38E-09
4.87E-09 5.15E-09
-7.59E-09 -6.04E-09
4.53E-09 4.64E-09
-6.50E-10 -6.00E-11
1.56E-08 1.78E-08
6.08E-09 1.21E-08
Total Dose
20
7.09E-09
3.58E-09
-2.41E-09
-2.02E-09
7.08E-09
9.57E-09
5.57E-09
-6.11E-09
5.23E-09
6.20E-10
1.90E-08
1.24E-08
(krad(Si))
30
4.79E-09
2.08E-09
-2.93E-09
-2.16E-09
5.94E-09
1.00E-08
6.23E-09
-4.78E-09
5.38E-09
6.00E-11
1.96E-08
1.21E-08
50
1.84E-09
-2.70E-10
-6.03E-09
-5.55E-09
1.10E-09
8.87E-09
4.21E-09
-6.58E-09
3.25E-09
-1.78E-09
1.89E-08
1.06E-08
24 Hr
Anneal
60
3.04E-09
1.25E-09
-3.93E-09
-3.88E-09
3.82E-09
1.06E-08
5.67E-09
-4.06E-09
5.79E-09
2.60E-10
2.01E-08
1.10E-08
168 Hr
Anneal
70
1.78E-09
-1.36E-09
-2.10E-09
-5.31E-09
2.89E-09
8.39E-09
4.33E-09
-8.41E-09
3.26E-09
-1.18E-09
2.10E-08
1.16E-08
7.33E-09 4.67E-09 2.66E-09 1.54E-09 -1.78E-09 6.00E-11 -8.20E-10
4.60E-09 4.85E-09 4.68E-09 4.00E-09 3.74E-09 3.74E-09 3.26E-09
2.00E-08 1.80E-08 1.55E-08 1.25E-08 8.47E-09 1.03E-08 8.13E-09
-5.29E-09 -8.64E-09 -1.02E-08 -9.41E-09 -1.20E-08 -1.02E-08 -9.77E-09
1.77E-09
6.04E-09
1.83E-08
-1.48E-08
-7.00E-08
PASS
7.00E-08
PASS
2.41E-09
5.60E-09
1.78E-08
-1.30E-08
-1.00E-07
PASS
1.00E-07
PASS
2.98E-09
5.99E-09
1.94E-08
-1.34E-08
-1.00E-07
PASS
1.00E-07
PASS
3.38E-09
5.78E-09
1.92E-08
-1.25E-08
-1.00E-07
PASS
1.00E-07
PASS
1.59E-09
5.93E-09
1.79E-08
-1.47E-08
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
62
3.66E-09
5.66E-09
1.92E-08
-1.19E-08
-1.00E-07
PASS
1.00E-07
PASS
1.28E-09
6.40E-09
1.88E-08
-1.63E-08
-1.00E-07
PASS
1.00E-07
PASS
Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.26. Plot of Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
63
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.26. Raw data for Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current2 4 15V (A)
@ VS=+/-15V, VCM=15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-4.46E-09
-5.78E-09
-2.98E-09
-2.11E-09
-7.44E-09
3.39E-09
-1.04E-08
1.30E-08
-5.01E-09
3.60E-10
-3.69E-09
-9.39E-09
10
-2.21E-09
-4.45E-09
-2.52E-09
-1.83E-09
-7.95E-09
7.37E-09
-6.00E-09
1.89E-08
-6.10E-10
4.73E-09
2.33E-09
8.40E-10
Total Dose
20
-3.42E-09
-5.50E-09
-4.19E-09
-3.07E-09
-9.99E-09
9.97E-09
-4.10E-09
2.08E-08
9.00E-10
5.95E-09
4.89E-09
2.79E-09
(krad(Si))
30
-4.74E-09
-6.32E-09
-4.95E-09
-3.99E-09
-9.94E-09
1.09E-08
-2.59E-09
2.25E-08
1.50E-09
5.63E-09
6.33E-09
3.16E-09
50
-8.64E-09
-9.23E-09
-6.83E-09
-4.94E-09
-1.21E-08
1.23E-08
-1.60E-09
2.53E-08
3.09E-09
7.13E-09
6.98E-09
3.71E-09
24 Hr
Anneal
60
-6.48E-09
-7.11E-09
-4.60E-09
-2.23E-09
-1.03E-08
1.38E-08
6.50E-10
2.76E-08
4.05E-09
9.23E-09
7.58E-09
2.99E-09
168 Hr
Anneal
70
-7.54E-09
-7.11E-09
-5.91E-09
-3.69E-09
-1.18E-08
1.05E-08
-3.25E-09
2.23E-08
1.00E-09
6.94E-09
8.56E-09
4.06E-09
-4.55E-09 -3.79E-09 -5.23E-09 -5.99E-09 -8.34E-09 -6.14E-09 -7.20E-09
2.14E-09 2.53E-09 2.82E-09 2.36E-09 2.68E-09 3.00E-09 2.95E-09
1.31E-09 3.16E-09 2.49E-09 4.94E-10 -9.98E-10 2.08E-09 8.89E-10
-1.04E-08 -1.07E-08 -1.30E-08 -1.25E-08 -1.57E-08 -1.44E-08 -1.53E-08
2.62E-10
8.84E-09
2.45E-08
-2.40E-08
-7.00E-08
PASS
7.00E-08
PASS
4.87E-09
9.36E-09
3.05E-08
-2.08E-08
-1.00E-07
PASS
1.00E-07
PASS
6.71E-09
9.50E-09
3.28E-08
-1.93E-08
-1.00E-07
PASS
1.00E-07
PASS
7.59E-09
9.72E-09
3.42E-08
-1.91E-08
-1.00E-07
PASS
1.00E-07
PASS
9.24E-09
1.03E-08
3.75E-08
-1.90E-08
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
64
1.11E-08
1.05E-08
3.99E-08
-1.77E-08
-1.00E-07
PASS
1.00E-07
PASS
7.50E-09
9.83E-09
3.45E-08
-1.95E-08
-1.00E-07
PASS
1.00E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS2 1 15V (A)
@ VS=+/-15V, VCM=15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.27. Plot of +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
65
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.27. Raw data for +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS2 1 15V (A)
@ VS=+/-15V, VCM=15V
Device
0
10
557 3.41E-07 3.54E-07
563 3.38E-07 3.64E-07
564 3.51E-07 3.77E-07
567 3.40E-07 3.64E-07
569 3.54E-07 3.82E-07
570 3.38E-07 3.46E-07
571 3.42E-07 3.53E-07
572 3.47E-07 3.57E-07
573 3.36E-07 3.41E-07
574 3.44E-07 3.49E-07
584 3.28E-07 3.31E-07
585 3.46E-07 3.53E-07
Biased Statistics
Average Biased
3.45E-07 3.68E-07
Std Dev Biased
7.20E-09 1.11E-08
Ps90%/90% (+KTL) Biased
3.64E-07 3.98E-07
Ps90%/90% (-KTL) Biased
3.25E-07 3.38E-07
Un-Biased Statistics
Average Un-Biased
3.41E-07 3.49E-07
Std Dev Un-Biased
4.30E-09 6.27E-09
Ps90%/90% (+KTL) Un-Biased
3.53E-07 3.67E-07
Ps90%/90% (-KTL) Un-Biased
3.30E-07 3.32E-07
Specification MIN
-7.15E-07 -7.65E-07
Status
PASS
PASS
Specification MAX
7.15E-07 7.65E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.73E-07 3.88E-07
3.81E-07 3.91E-07
3.97E-07 4.08E-07
3.85E-07 3.97E-07
4.03E-07 4.16E-07
3.62E-07 3.79E-07
3.69E-07 3.88E-07
3.75E-07 3.95E-07
3.54E-07 3.74E-07
3.64E-07 3.85E-07
3.32E-07 3.33E-07
3.49E-07 3.55E-07
3.88E-07
1.22E-08
4.21E-07
3.55E-07
4.00E-07
1.18E-08
4.33E-07
3.68E-07
168 Hr
Anneal
70
3.89E-07
3.90E-07
4.05E-07
3.92E-07
4.11E-07
3.87E-07
3.97E-07
4.07E-07
3.84E-07
3.94E-07
3.37E-07
3.55E-07
4.29E-07
1.03E-08
4.57E-07
4.01E-07
4.29E-07
1.17E-08
4.61E-07
3.97E-07
3.97E-07
1.02E-08
4.25E-07
3.70E-07
3.65E-07 3.84E-07 4.21E-07 4.21E-07 3.93E-07
7.84E-09 8.00E-09 7.98E-09 8.79E-09 9.05E-09
3.86E-07 4.06E-07 4.43E-07 4.45E-07 4.18E-07
3.43E-07 3.62E-07 3.99E-07 3.97E-07 3.69E-07
-8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07
PASS
PASS
PASS
PASS
PASS
8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
66
50
4.19E-07
4.22E-07
4.36E-07
4.23E-07
4.43E-07
4.16E-07
4.24E-07
4.33E-07
4.12E-07
4.21E-07
3.35E-07
3.57E-07
24 Hr
Anneal
60
4.19E-07
4.22E-07
4.37E-07
4.21E-07
4.45E-07
4.16E-07
4.26E-07
4.34E-07
4.12E-07
4.20E-07
3.37E-07
3.60E-07
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS2 2 15V (A)
@ VS=+/-15V, VCM=15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.28. Plot of +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
67
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.28. Raw data for +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS2 2 15V (A)
@ VS=+/-15V, VCM=15V
Device
0
10
557 3.37E-07 3.50E-07
563 3.45E-07 3.70E-07
564 3.48E-07 3.73E-07
567 3.45E-07 3.70E-07
569 3.40E-07 3.64E-07
570 3.41E-07 3.45E-07
571 3.38E-07 3.44E-07
572 3.37E-07 3.42E-07
573 3.28E-07 3.33E-07
574 3.51E-07 3.56E-07
584 3.44E-07 3.48E-07
585 3.53E-07 3.61E-07
Biased Statistics
Average Biased
3.43E-07 3.65E-07
Std Dev Biased
4.57E-09 9.37E-09
Ps90%/90% (+KTL) Biased
3.56E-07 3.91E-07
Ps90%/90% (-KTL) Biased
3.31E-07 3.40E-07
Un-Biased Statistics
Average Un-Biased
3.39E-07 3.44E-07
Std Dev Un-Biased
8.04E-09 8.27E-09
Ps90%/90% (+KTL) Un-Biased
3.61E-07 3.67E-07
Ps90%/90% (-KTL) Un-Biased
3.17E-07 3.21E-07
Specification MIN
-7.15E-07 -7.65E-07
Status
PASS
PASS
Specification MAX
7.15E-07 7.65E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.71E-07 3.87E-07
3.87E-07 4.00E-07
3.94E-07 4.05E-07
3.89E-07 4.01E-07
3.86E-07 3.98E-07
3.61E-07 3.80E-07
3.58E-07 3.77E-07
3.58E-07 3.78E-07
3.46E-07 3.64E-07
3.74E-07 3.94E-07
3.50E-07 3.49E-07
3.58E-07 3.63E-07
3.85E-07
8.50E-09
4.09E-07
3.62E-07
3.98E-07
6.83E-09
4.17E-07
3.79E-07
168 Hr
Anneal
70
3.89E-07
3.96E-07
4.02E-07
3.96E-07
3.92E-07
3.89E-07
3.87E-07
3.86E-07
3.74E-07
4.04E-07
3.52E-07
3.62E-07
4.26E-07
4.72E-09
4.39E-07
4.13E-07
4.26E-07
5.72E-09
4.42E-07
4.11E-07
3.95E-07
5.03E-09
4.09E-07
3.81E-07
3.59E-07 3.79E-07 4.16E-07 4.15E-07 3.88E-07
9.75E-09 1.06E-08 1.19E-08 1.15E-08 1.07E-08
3.86E-07 4.08E-07 4.48E-07 4.47E-07 4.17E-07
3.33E-07 3.50E-07 3.83E-07 3.84E-07 3.58E-07
-8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07
PASS
PASS
PASS
PASS
PASS
8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
68
50
4.22E-07
4.25E-07
4.34E-07
4.28E-07
4.23E-07
4.17E-07
4.13E-07
4.14E-07
4.01E-07
4.34E-07
3.51E-07
3.64E-07
24 Hr
Anneal
60
4.19E-07
4.26E-07
4.35E-07
4.26E-07
4.25E-07
4.16E-07
4.13E-07
4.16E-07
3.99E-07
4.31E-07
3.51E-07
3.66E-07
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS2 3 15V (A)
@ VS=+/-15V, VCM=15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.29. Plot of +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
69
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.29. Raw data for +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS2 3 15V (A)
@ VS=+/-15V, VCM=15V
Device
0
10
557 3.49E-07 3.62E-07
563 3.59E-07 3.78E-07
564 3.69E-07 3.93E-07
567 3.38E-07 3.60E-07
569 3.51E-07 3.76E-07
570 3.46E-07 3.53E-07
571 3.39E-07 3.41E-07
572 3.43E-07 3.51E-07
573 3.29E-07 3.31E-07
574 3.55E-07 3.59E-07
584 3.55E-07 3.57E-07
585 3.57E-07 3.63E-07
Biased Statistics
Average Biased
3.53E-07 3.74E-07
Std Dev Biased
1.14E-08 1.33E-08
Ps90%/90% (+KTL) Biased
3.85E-07 4.10E-07
Ps90%/90% (-KTL) Biased
3.22E-07 3.37E-07
Un-Biased Statistics
Average Un-Biased
3.42E-07 3.47E-07
Std Dev Un-Biased
9.43E-09 1.09E-08
Ps90%/90% (+KTL) Un-Biased
3.68E-07 3.77E-07
Ps90%/90% (-KTL) Un-Biased
3.16E-07 3.17E-07
Specification MIN
-7.15E-07 -7.65E-07
Status
PASS
PASS
Specification MAX
7.15E-07 7.65E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.83E-07 3.96E-07
3.95E-07 4.06E-07
4.12E-07 4.21E-07
3.79E-07 3.91E-07
3.96E-07 4.08E-07
3.67E-07 3.85E-07
3.57E-07 3.73E-07
3.67E-07 3.87E-07
3.42E-07 3.61E-07
3.75E-07 3.93E-07
3.58E-07 3.57E-07
3.58E-07 3.63E-07
3.93E-07
1.30E-08
4.29E-07
3.57E-07
4.05E-07
1.17E-08
4.37E-07
3.73E-07
168 Hr
Anneal
70
3.95E-07
4.02E-07
4.16E-07
3.83E-07
4.02E-07
3.91E-07
3.81E-07
3.92E-07
3.69E-07
4.05E-07
3.58E-07
3.60E-07
4.31E-07
1.25E-08
4.65E-07
3.97E-07
4.31E-07
1.32E-08
4.67E-07
3.95E-07
4.00E-07
1.19E-08
4.32E-07
3.67E-07
3.62E-07 3.80E-07 4.15E-07 4.15E-07 3.87E-07
1.27E-08 1.30E-08 1.55E-08 1.53E-08 1.36E-08
3.96E-07 4.15E-07 4.58E-07 4.57E-07 4.25E-07
3.27E-07 3.44E-07 3.73E-07 3.72E-07 3.50E-07
-8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07
PASS
PASS
PASS
PASS
PASS
8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
70
50
4.26E-07
4.35E-07
4.48E-07
4.14E-07
4.32E-07
4.20E-07
4.08E-07
4.20E-07
3.93E-07
4.35E-07
3.57E-07
3.64E-07
24 Hr
Anneal
60
4.26E-07
4.33E-07
4.49E-07
4.13E-07
4.33E-07
4.19E-07
4.07E-07
4.22E-07
3.92E-07
4.32E-07
3.58E-07
3.65E-07
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS2 4 15V (A)
@ VS=+/-15V, VCM=15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.30. Plot of +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
71
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.30. Raw data for +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS2 4 15V (A)
@ VS=+/-15V, VCM=15V
Device
0
10
557 3.39E-07 3.48E-07
563 3.41E-07 3.65E-07
564 3.47E-07 3.72E-07
567 3.48E-07 3.73E-07
569 3.44E-07 3.71E-07
570 3.51E-07 3.57E-07
571 3.35E-07 3.41E-07
572 3.63E-07 3.73E-07
573 3.41E-07 3.42E-07
574 3.40E-07 3.46E-07
584 3.33E-07 3.36E-07
585 3.45E-07 3.54E-07
Biased Statistics
Average Biased
3.44E-07 3.66E-07
Std Dev Biased
3.83E-09 1.04E-08
Ps90%/90% (+KTL) Biased
3.54E-07 3.95E-07
Ps90%/90% (-KTL) Biased
3.33E-07 3.38E-07
Un-Biased Statistics
Average Un-Biased
3.46E-07 3.52E-07
Std Dev Un-Biased
1.12E-08 1.37E-08
Ps90%/90% (+KTL) Un-Biased
3.76E-07 3.89E-07
Ps90%/90% (-KTL) Un-Biased
3.15E-07 3.14E-07
Specification MIN
-7.15E-07 -7.65E-07
Status
PASS
PASS
Specification MAX
7.15E-07 7.65E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.69E-07 3.84E-07
3.82E-07 3.96E-07
3.92E-07 4.02E-07
3.93E-07 4.06E-07
3.94E-07 4.04E-07
3.75E-07 3.91E-07
3.57E-07 3.77E-07
3.90E-07 4.11E-07
3.58E-07 3.78E-07
3.61E-07 3.81E-07
3.37E-07 3.38E-07
3.51E-07 3.56E-07
3.86E-07
1.08E-08
4.16E-07
3.57E-07
3.99E-07
8.86E-09
4.23E-07
3.74E-07
168 Hr
Anneal
70
3.86E-07
3.95E-07
3.99E-07
4.03E-07
4.00E-07
3.99E-07
3.85E-07
4.23E-07
3.87E-07
3.92E-07
3.37E-07
3.54E-07
4.27E-07
6.62E-09
4.45E-07
4.08E-07
4.27E-07
7.56E-09
4.48E-07
4.06E-07
3.96E-07
6.28E-09
4.14E-07
3.79E-07
3.68E-07 3.88E-07 4.25E-07 4.25E-07 3.97E-07
1.44E-08 1.43E-08 1.49E-08 1.53E-08 1.53E-08
4.08E-07 4.27E-07 4.66E-07 4.67E-07 4.39E-07
3.29E-07 3.48E-07 3.84E-07 3.83E-07 3.55E-07
-8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07
PASS
PASS
PASS
PASS
PASS
8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
72
50
4.16E-07
4.26E-07
4.29E-07
4.33E-07
4.30E-07
4.28E-07
4.12E-07
4.50E-07
4.17E-07
4.19E-07
3.40E-07
3.58E-07
24 Hr
Anneal
60
4.15E-07
4.24E-07
4.31E-07
4.32E-07
4.33E-07
4.27E-07
4.14E-07
4.51E-07
4.15E-07
4.18E-07
3.38E-07
3.60E-07
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS2 1 15V (A)
@ VS=+/-15V, VCM=15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.31. Plot of -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
73
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.31. Raw data for -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS2 1 15V (A)
@ VS=+/-15V, VCM=15V
Device
0
10
557 3.47E-07 3.61E-07
563 3.37E-07 3.63E-07
564 3.50E-07 3.79E-07
567 3.40E-07 3.67E-07
569 3.42E-07 3.72E-07
570 3.37E-07 3.45E-07
571 3.36E-07 3.39E-07
572 3.46E-07 3.53E-07
573 3.38E-07 3.35E-07
574 3.37E-07 3.35E-07
584 3.29E-07 3.28E-07
585 3.43E-07 3.44E-07
Biased Statistics
Average Biased
3.43E-07 3.68E-07
Std Dev Biased
5.31E-09 7.24E-09
Ps90%/90% (+KTL) Biased
3.58E-07 3.88E-07
Ps90%/90% (-KTL) Biased
3.29E-07 3.48E-07
Un-Biased Statistics
Average Un-Biased
3.39E-07 3.42E-07
Std Dev Un-Biased
4.08E-09 7.80E-09
Ps90%/90% (+KTL) Un-Biased
3.50E-07 3.63E-07
Ps90%/90% (-KTL) Un-Biased
3.28E-07 3.20E-07
Specification MIN
-7.15E-07 -7.65E-07
Status
PASS
PASS
Specification MAX
7.15E-07 7.65E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.85E-07 4.01E-07
3.84E-07 3.99E-07
4.03E-07 4.15E-07
3.90E-07 4.02E-07
3.95E-07 4.07E-07
3.60E-07 3.77E-07
3.53E-07 3.72E-07
3.71E-07 3.91E-07
3.53E-07 3.71E-07
3.50E-07 3.69E-07
3.29E-07 3.28E-07
3.41E-07 3.46E-07
3.92E-07
8.04E-09
4.14E-07
3.69E-07
4.05E-07
6.21E-09
4.22E-07
3.88E-07
168 Hr
Anneal
70
4.05E-07
3.98E-07
4.10E-07
3.98E-07
4.04E-07
3.85E-07
3.82E-07
4.04E-07
3.81E-07
3.79E-07
3.30E-07
3.44E-07
4.37E-07
5.93E-09
4.53E-07
4.21E-07
4.34E-07
6.84E-09
4.53E-07
4.15E-07
4.03E-07
5.02E-09
4.17E-07
3.89E-07
3.58E-07 3.76E-07 4.14E-07 4.11E-07 3.86E-07
8.57E-09 8.78E-09 9.67E-09 9.54E-09 1.00E-08
3.81E-07 4.00E-07 4.40E-07 4.37E-07 4.13E-07
3.34E-07 3.52E-07 3.87E-07 3.85E-07 3.59E-07
-8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07
PASS
PASS
PASS
PASS
PASS
8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
74
50
4.39E-07
4.30E-07
4.44E-07
4.32E-07
4.39E-07
4.15E-07
4.07E-07
4.30E-07
4.09E-07
4.07E-07
3.30E-07
3.49E-07
24 Hr
Anneal
60
4.36E-07
4.28E-07
4.43E-07
4.27E-07
4.38E-07
4.12E-07
4.07E-07
4.27E-07
4.06E-07
4.03E-07
3.31E-07
3.52E-07
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS2 2 15V (A)
@ VS=+/-15V, VCM=15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.32. Plot of -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
75
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.32. Raw data for -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS2 2 15V (A)
@ VS=+/-15V, VCM=15V
Device
0
10
557 3.31E-07 3.41E-07
563 3.41E-07 3.65E-07
564 3.42E-07 3.69E-07
567 3.36E-07 3.59E-07
569 3.37E-07 3.62E-07
570 3.37E-07 3.44E-07
571 3.33E-07 3.40E-07
572 3.34E-07 3.41E-07
573 3.23E-07 3.27E-07
574 3.39E-07 3.38E-07
584 3.37E-07 3.40E-07
585 3.36E-07 3.40E-07
Biased Statistics
Average Biased
3.37E-07 3.59E-07
Std Dev Biased
4.31E-09 1.08E-08
Ps90%/90% (+KTL) Biased
3.49E-07 3.89E-07
Ps90%/90% (-KTL) Biased
3.26E-07 3.30E-07
Un-Biased Statistics
Average Un-Biased
3.33E-07 3.38E-07
Std Dev Un-Biased
6.10E-09 6.58E-09
Ps90%/90% (+KTL) Un-Biased
3.50E-07 3.56E-07
Ps90%/90% (-KTL) Un-Biased
3.16E-07 3.20E-07
Specification MIN
-7.15E-07 -7.65E-07
Status
PASS
PASS
Specification MAX
7.15E-07 7.65E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.65E-07 3.83E-07
3.85E-07 4.00E-07
3.93E-07 4.04E-07
3.80E-07 3.92E-07
3.86E-07 3.98E-07
3.61E-07 3.79E-07
3.49E-07 3.68E-07
3.52E-07 3.70E-07
3.36E-07 3.54E-07
3.54E-07 3.74E-07
3.41E-07 3.39E-07
3.34E-07 3.39E-07
3.82E-07
1.03E-08
4.10E-07
3.54E-07
3.95E-07
8.40E-09
4.18E-07
3.72E-07
168 Hr
Anneal
70
3.88E-07
3.98E-07
4.02E-07
3.90E-07
3.95E-07
3.88E-07
3.77E-07
3.81E-07
3.64E-07
3.86E-07
3.39E-07
3.38E-07
4.26E-07
5.43E-09
4.41E-07
4.11E-07
4.24E-07
6.97E-09
4.43E-07
4.05E-07
3.95E-07
5.91E-09
4.11E-07
3.78E-07
3.50E-07 3.69E-07 4.06E-07 4.04E-07 3.79E-07
9.05E-09 9.43E-09 1.02E-08 1.10E-08 9.33E-09
3.75E-07 3.95E-07 4.34E-07 4.34E-07 4.05E-07
3.26E-07 3.43E-07 3.78E-07 3.74E-07 3.54E-07
-8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07
PASS
PASS
PASS
PASS
PASS
8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
76
50
4.21E-07
4.27E-07
4.34E-07
4.21E-07
4.27E-07
4.13E-07
4.05E-07
4.08E-07
3.89E-07
4.14E-07
3.40E-07
3.43E-07
24 Hr
Anneal
60
4.17E-07
4.26E-07
4.34E-07
4.17E-07
4.25E-07
4.13E-07
4.03E-07
4.06E-07
3.85E-07
4.12E-07
3.42E-07
3.44E-07
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS2 3 15V (A)
@ VS=+/-15V, VCM=15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.33. Plot of -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
77
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.33. Raw data for -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS2 3 15V (A)
@ VS=+/-15V, VCM=15V
Device
0
10
557 3.37E-07 3.47E-07
563 3.47E-07 3.70E-07
564 3.59E-07 3.88E-07
567 3.34E-07 3.57E-07
569 3.39E-07 3.65E-07
570 3.39E-07 3.40E-07
571 3.30E-07 3.37E-07
572 3.44E-07 3.51E-07
573 3.21E-07 3.25E-07
574 3.50E-07 3.55E-07
584 3.35E-07 3.37E-07
585 3.46E-07 3.47E-07
Biased Statistics
Average Biased
3.43E-07 3.65E-07
Std Dev Biased
1.01E-08 1.52E-08
Ps90%/90% (+KTL) Biased
3.71E-07 4.07E-07
Ps90%/90% (-KTL) Biased
3.16E-07 3.24E-07
Un-Biased Statistics
Average Un-Biased
3.37E-07 3.42E-07
Std Dev Un-Biased
1.14E-08 1.22E-08
Ps90%/90% (+KTL) Un-Biased
3.68E-07 3.75E-07
Ps90%/90% (-KTL) Un-Biased
3.05E-07 3.08E-07
Specification MIN
-7.15E-07 -7.65E-07
Status
PASS
PASS
Specification MAX
7.15E-07 7.65E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.71E-07 3.88E-07
3.89E-07 4.02E-07
4.11E-07 4.23E-07
3.79E-07 3.90E-07
3.88E-07 4.01E-07
3.55E-07 3.70E-07
3.45E-07 3.65E-07
3.69E-07 3.87E-07
3.41E-07 3.52E-07
3.72E-07 3.92E-07
3.37E-07 3.36E-07
3.44E-07 3.48E-07
3.87E-07
1.49E-08
4.28E-07
3.47E-07
4.01E-07
1.39E-08
4.39E-07
3.63E-07
168 Hr
Anneal
70
3.92E-07
4.02E-07
4.17E-07
3.88E-07
3.97E-07
3.81E-07
3.75E-07
3.98E-07
3.64E-07
4.03E-07
3.36E-07
3.47E-07
4.32E-07
1.32E-08
4.68E-07
3.96E-07
4.30E-07
1.36E-08
4.67E-07
3.92E-07
3.99E-07
1.12E-08
4.30E-07
3.68E-07
3.56E-07 3.73E-07 4.12E-07 4.09E-07 3.84E-07
1.37E-08 1.63E-08 1.84E-08 1.80E-08 1.60E-08
3.94E-07 4.18E-07 4.62E-07 4.59E-07 4.28E-07
3.19E-07 3.29E-07 3.62E-07 3.60E-07 3.40E-07
-8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07
PASS
PASS
PASS
PASS
PASS
8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
78
50
4.26E-07
4.32E-07
4.54E-07
4.19E-07
4.30E-07
4.09E-07
4.02E-07
4.26E-07
3.88E-07
4.34E-07
3.38E-07
3.51E-07
24 Hr
Anneal
60
4.22E-07
4.31E-07
4.52E-07
4.16E-07
4.29E-07
4.08E-07
4.00E-07
4.23E-07
3.85E-07
4.30E-07
3.37E-07
3.53E-07
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS2 4 15V (A)
@ VS=+/-15V, VCM=15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.34. Plot of -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
79
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.34. Raw data for -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS2 4 15V (A)
@ VS=+/-15V, VCM=15V
Device
0
10
557 3.38E-07 3.47E-07
563 3.39E-07 3.64E-07
564 3.42E-07 3.70E-07
567 3.44E-07 3.71E-07
569 3.45E-07 3.75E-07
570 3.40E-07 3.47E-07
571 3.40E-07 3.42E-07
572 3.41E-07 3.50E-07
573 3.41E-07 3.37E-07
574 3.39E-07 3.37E-07
584 3.32E-07 3.31E-07
585 3.45E-07 3.48E-07
Biased Statistics
Average Biased
3.41E-07 3.65E-07
Std Dev Biased
3.02E-09 1.10E-08
Ps90%/90% (+KTL) Biased
3.50E-07 3.96E-07
Ps90%/90% (-KTL) Biased
3.33E-07 3.35E-07
Un-Biased Statistics
Average Un-Biased
3.40E-07 3.43E-07
Std Dev Un-Biased
8.25E-10 5.76E-09
Ps90%/90% (+KTL) Un-Biased
3.42E-07 3.58E-07
Ps90%/90% (-KTL) Un-Biased
3.38E-07 3.27E-07
Specification MIN
-7.15E-07 -7.65E-07
Status
PASS
PASS
Specification MAX
7.15E-07 7.65E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.69E-07 3.86E-07
3.85E-07 3.99E-07
3.92E-07 4.04E-07
3.94E-07 4.08E-07
3.99E-07 4.14E-07
3.61E-07 3.78E-07
3.56E-07 3.74E-07
3.67E-07 3.86E-07
3.54E-07 3.75E-07
3.53E-07 3.71E-07
3.31E-07 3.31E-07
3.44E-07 3.50E-07
3.88E-07
1.18E-08
4.20E-07
3.56E-07
4.02E-07
1.07E-08
4.31E-07
3.73E-07
168 Hr
Anneal
70
3.90E-07
3.98E-07
4.02E-07
4.04E-07
4.09E-07
3.85E-07
3.85E-07
3.98E-07
3.83E-07
3.81E-07
3.33E-07
3.48E-07
4.33E-07
8.35E-09
4.56E-07
4.10E-07
4.31E-07
7.70E-09
4.52E-07
4.10E-07
4.00E-07
7.13E-09
4.20E-07
3.81E-07
3.58E-07 3.77E-07 4.14E-07 4.12E-07 3.86E-07
5.84E-09 5.64E-09 4.81E-09 5.96E-09 6.61E-09
3.74E-07 3.92E-07 4.27E-07 4.28E-07 4.05E-07
3.42E-07 3.61E-07 4.00E-07 3.95E-07 3.68E-07
-8.15E-07 -8.15E-07 -8.65E-07 -8.65E-07 -8.65E-07
PASS
PASS
PASS
PASS
PASS
8.15E-07 8.15E-07 8.65E-07 8.65E-07 8.65E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
80
50
4.21E-07
4.30E-07
4.34E-07
4.37E-07
4.43E-07
4.13E-07
4.11E-07
4.22E-07
4.11E-07
4.10E-07
3.33E-07
3.51E-07
24 Hr
Anneal
60
4.20E-07
4.28E-07
4.34E-07
4.33E-07
4.41E-07
4.11E-07
4.11E-07
4.22E-07
4.08E-07
4.07E-07
3.34E-07
3.54E-07
Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.35. Plot of Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
81
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.35. Raw data for Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage3 1 15V (V)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.06E-04
-1.55E-04
-4.30E-07
1.41E-05
-1.79E-04
9.51E-05
-2.68E-04
1.63E-04
6.93E-06
-3.11E-05
-4.62E-04
1.27E-04
Total Dose (krad(Si))
20
30
-2.16E-04 -2.19E-04
-1.64E-04 -1.65E-04
-7.80E-06 -5.50E-06
1.14E-06 2.46E-06
-1.85E-04 -1.85E-04
8.14E-05 7.84E-05
-2.79E-04 -2.80E-04
1.47E-04 1.47E-04
4.10E-07 -3.45E-06
-3.88E-05 -4.14E-05
-4.63E-04 -4.63E-04
1.27E-04 1.22E-04
10
-2.15E-04
-1.61E-04
-7.68E-06
4.52E-06
-1.88E-04
8.35E-05
-2.76E-04
1.50E-04
1.98E-06
-4.02E-05
-4.62E-04
1.21E-04
50
-2.27E-04
-1.70E-04
-1.33E-05
1.75E-06
-1.88E-04
7.09E-05
-2.84E-04
1.44E-04
-9.48E-06
-4.87E-05
-4.65E-04
1.23E-04
24 Hr
Anneal
60
-2.24E-04
-1.70E-04
-1.55E-05
1.39E-06
-1.90E-04
6.78E-05
-2.85E-04
1.43E-04
-1.08E-05
-5.10E-05
-4.66E-04
1.18E-04
168 Hr
Anneal
70
-2.20E-04
-1.86E-04
-1.25E-05
-2.36E-06
-1.89E-04
7.23E-05
-2.90E-04
1.37E-04
-2.10E-05
-5.07E-05
-4.65E-04
1.21E-04
-1.05E-04 -1.13E-04 -1.14E-04 -1.14E-04 -1.19E-04 -1.20E-04 -1.22E-04
1.04E-04 1.04E-04 1.03E-04 1.05E-04 1.06E-04 1.05E-04 1.05E-04
1.80E-04 1.72E-04 1.68E-04 1.73E-04 1.71E-04 1.67E-04 1.67E-04
-3.91E-04 -3.99E-04 -3.97E-04 -4.02E-04 -4.09E-04 -4.06E-04 -4.11E-04
-6.93E-06
1.65E-04
4.44E-04
-4.58E-04
-8.00E-04
PASS
8.00E-04
PASS
-1.61E-05
1.63E-04
4.31E-04
-4.63E-04
-9.50E-04
PASS
9.50E-04
PASS
-1.77E-05
1.63E-04
4.28E-04
-4.64E-04
-9.50E-04
PASS
9.50E-04
PASS
-1.99E-05
1.63E-04
4.26E-04
-4.66E-04
-9.50E-04
PASS
9.50E-04
PASS
-2.56E-05
1.62E-04
4.20E-04
-4.71E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
82
-2.72E-05
1.62E-04
4.17E-04
-4.72E-04
-9.50E-04
PASS
9.50E-04
PASS
-3.05E-05
1.63E-04
4.17E-04
-4.78E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.36. Plot of Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
83
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.36. Raw data for Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage3 2 15V (V)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-2.51E-04
-2.25E-04
-2.45E-05
-1.65E-04
-6.25E-05
-6.85E-05
4.98E-05
1.09E-05
-1.95E-04
-3.68E-05
-3.34E-04
-3.10E-07
Total Dose (krad(Si))
20
30
-2.59E-04 -2.57E-04
-2.33E-04 -2.35E-04
-2.91E-05 -2.89E-05
-1.69E-04 -1.68E-04
-6.62E-05 -6.59E-05
-7.75E-05 -7.82E-05
4.57E-05 4.80E-05
-5.02E-06 -7.68E-06
-1.99E-04 -2.01E-04
-4.29E-05 -4.50E-05
-3.37E-04 -3.35E-04
-3.45E-06 -5.87E-06
10
-2.58E-04
-2.32E-04
-3.04E-05
-1.67E-04
-6.35E-05
-7.55E-05
4.79E-05
-4.17E-06
-2.01E-04
-4.33E-05
-3.35E-04
-4.42E-06
50
-2.61E-04
-2.37E-04
-3.68E-05
-1.75E-04
-6.55E-05
-8.07E-05
4.61E-05
-1.11E-05
-1.98E-04
-4.97E-05
-3.35E-04
5.40E-07
24 Hr
Anneal
60
-2.62E-04
-2.33E-04
-3.41E-05
-1.77E-04
-6.45E-05
-8.07E-05
4.57E-05
-1.08E-05
-2.01E-04
-4.88E-05
-3.33E-04
-6.22E-06
168 Hr
Anneal
70
-2.66E-04
-2.28E-04
-2.72E-05
-1.57E-04
-7.05E-05
-7.93E-05
3.24E-05
-1.41E-05
-2.07E-04
-4.87E-05
-3.35E-04
-3.45E-06
-1.46E-04 -1.50E-04 -1.51E-04 -1.51E-04 -1.55E-04 -1.54E-04 -1.50E-04
9.92E-05 1.01E-04 1.01E-04 1.01E-04 1.00E-04 1.01E-04 1.01E-04
1.27E-04 1.26E-04 1.26E-04 1.26E-04 1.20E-04 1.23E-04 1.28E-04
-4.18E-04 -4.26E-04 -4.28E-04 -4.28E-04 -4.30E-04 -4.31E-04 -4.27E-04
-4.80E-05
9.40E-05
2.10E-04
-3.06E-04
-8.00E-04
PASS
8.00E-04
PASS
-5.52E-05
9.35E-05
2.01E-04
-3.11E-04
-9.50E-04
PASS
9.50E-04
PASS
-5.58E-05
9.23E-05
1.97E-04
-3.09E-04
-9.50E-04
PASS
9.50E-04
PASS
-5.68E-05
9.34E-05
1.99E-04
-3.13E-04
-9.50E-04
PASS
9.50E-04
PASS
-5.86E-05
9.11E-05
1.91E-04
-3.08E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
84
-5.91E-05
9.21E-05
1.93E-04
-3.12E-04
-9.50E-04
PASS
9.50E-04
PASS
-6.34E-05
9.06E-05
1.85E-04
-3.12E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.37. Plot of Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
85
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.37. Raw data for Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage3 3 15V (V)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
2.94E-04
-7.27E-05
-5.73E-05
-3.29E-05
-1.77E-04
-1.82E-04
-1.55E-04
2.30E-04
5.52E-05
1.08E-04
3.61E-04
3.75E-05
Total Dose (krad(Si))
20
30
2.80E-04 2.73E-04
-8.07E-05 -8.56E-05
-6.80E-05 -6.80E-05
-4.08E-05 -4.32E-05
-1.85E-04 -1.89E-04
-1.89E-04 -1.92E-04
-1.66E-04 -1.68E-04
2.16E-04 2.10E-04
5.09E-05 4.98E-05
1.00E-04 9.46E-05
3.63E-04 3.63E-04
3.48E-05 3.22E-05
10
2.83E-04
-7.93E-05
-6.14E-05
-3.40E-05
-1.80E-04
-1.88E-04
-1.64E-04
2.20E-04
5.09E-05
1.02E-04
3.64E-04
3.63E-05
50
2.67E-04
-8.43E-05
-7.34E-05
-4.50E-05
-1.91E-04
-1.96E-04
-1.77E-04
2.05E-04
4.28E-05
8.89E-05
3.62E-04
3.74E-05
24 Hr
Anneal
60
2.65E-04
-8.38E-05
-7.83E-05
-4.63E-05
-1.96E-04
-1.98E-04
-1.77E-04
2.02E-04
4.34E-05
8.86E-05
3.59E-04
2.90E-05
168 Hr
Anneal
70
2.61E-04
-7.98E-05
-8.24E-05
-5.07E-05
-1.88E-04
-1.93E-04
-1.64E-04
1.91E-04
3.98E-05
8.35E-05
3.60E-04
3.28E-05
-9.18E-06 -1.44E-05 -1.90E-05 -2.26E-05 -2.53E-05 -2.79E-05 -2.80E-05
1.78E-04 1.75E-04 1.76E-04 1.75E-04 1.72E-04 1.73E-04 1.69E-04
4.79E-04 4.66E-04 4.63E-04 4.56E-04 4.47E-04 4.48E-04 4.37E-04
-4.97E-04 -4.95E-04 -5.01E-04 -5.01E-04 -4.98E-04 -5.04E-04 -4.93E-04
1.11E-05
1.76E-04
4.94E-04
-4.72E-04
-8.00E-04
PASS
8.00E-04
PASS
4.25E-06
1.76E-04
4.86E-04
-4.77E-04
-9.50E-04
PASS
9.50E-04
PASS
2.42E-06
1.75E-04
4.83E-04
-4.78E-04
-9.50E-04
PASS
9.50E-04
PASS
-1.23E-06
1.74E-04
4.75E-04
-4.77E-04
-9.50E-04
PASS
9.50E-04
PASS
-7.14E-06
1.74E-04
4.70E-04
-4.85E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
86
-8.05E-06
1.74E-04
4.68E-04
-4.84E-04
-9.50E-04
PASS
9.50E-04
PASS
-8.49E-06
1.65E-04
4.43E-04
-4.60E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.38. Plot of Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
87
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.38. Raw data for Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage3 4 15V (V)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-6.17E-05
2.39E-05
1.26E-04
1.35E-04
-2.83E-04
8.81E-05
1.60E-04
-1.18E-05
6.08E-05
-2.46E-04
9.33E-05
-1.80E-04
Total Dose (krad(Si))
20
30
-7.35E-05 -7.48E-05
1.35E-05 1.49E-05
1.22E-04 1.23E-04
1.30E-04 1.31E-04
-2.87E-04 -2.92E-04
7.84E-05 8.17E-05
1.51E-04 1.51E-04
-2.56E-05 -2.51E-05
5.79E-05 6.04E-05
-2.52E-04 -2.51E-04
9.25E-05 9.27E-05
-1.80E-04 -1.80E-04
10
-7.15E-05
1.48E-05
1.22E-04
1.31E-04
-2.86E-04
7.85E-05
1.52E-04
-2.28E-05
5.47E-05
-2.53E-04
9.27E-05
-1.82E-04
50
-8.08E-05
8.27E-06
1.17E-04
1.26E-04
-2.88E-04
8.59E-05
1.48E-04
-2.99E-05
6.10E-05
-2.53E-04
8.93E-05
-1.79E-04
24 Hr
Anneal
60
-8.11E-05
5.85E-06
1.13E-04
1.25E-04
-2.89E-04
8.18E-05
1.45E-04
-3.28E-05
5.64E-05
-2.54E-04
8.64E-05
-1.83E-04
168 Hr
Anneal
70
-7.70E-05
1.59E-05
1.15E-04
1.24E-04
-2.85E-04
7.66E-05
1.47E-04
-2.60E-05
4.67E-05
-2.62E-04
8.87E-05
-1.82E-04
-1.18E-05 -1.80E-05 -1.89E-05 -1.94E-05 -2.36E-05 -2.53E-05 -2.15E-05
1.72E-04 1.71E-04 1.72E-04 1.74E-04 1.71E-04 1.70E-04 1.69E-04
4.59E-04 4.52E-04 4.52E-04 4.58E-04 4.44E-04 4.40E-04 4.41E-04
-4.82E-04 -4.88E-04 -4.90E-04 -4.97E-04 -4.92E-04 -4.91E-04 -4.84E-04
1.00E-05
1.56E-04
4.38E-04
-4.18E-04
-8.00E-04
PASS
8.00E-04
PASS
1.84E-06
1.55E-04
4.28E-04
-4.24E-04
-9.50E-04
PASS
9.50E-04
PASS
1.93E-06
1.55E-04
4.28E-04
-4.24E-04
-9.50E-04
PASS
9.50E-04
PASS
3.55E-06
1.55E-04
4.30E-04
-4.22E-04
-9.50E-04
PASS
9.50E-04
PASS
2.42E-06
1.56E-04
4.31E-04
-4.27E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
88
-6.18E-07
1.55E-04
4.25E-04
-4.26E-04
-9.50E-04
PASS
9.50E-04
PASS
-3.62E-06
1.57E-04
4.28E-04
-4.35E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.39. Plot of Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
89
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.39. Raw data for Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current3 1 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
2.35E-09
-4.26E-09
-3.30E-10
5.37E-09
1.69E-09
-1.30E-10
-5.52E-09
2.33E-09
-2.36E-09
5.13E-09
-8.69E-09
1.49E-09
10
2.17E-09
-4.85E-09
-5.20E-10
5.02E-09
5.00E-10
-4.00E-10
-5.73E-09
2.22E-09
-2.56E-09
4.94E-09
-9.31E-09
-2.20E-10
Total Dose
20
1.32E-09
-4.90E-09
-1.47E-09
4.50E-09
-1.80E-10
-6.00E-11
-6.40E-09
2.25E-09
-2.74E-09
5.10E-09
-9.69E-09
-2.90E-10
(krad(Si))
30
9.70E-10
-5.62E-09
-2.02E-09
4.61E-09
-1.03E-09
-1.10E-10
-6.67E-09
2.25E-09
-2.85E-09
4.72E-09
-1.00E-08
-2.50E-10
50
-3.80E-10
-6.94E-09
-3.91E-09
3.96E-09
-2.61E-09
3.40E-10
-6.72E-09
2.42E-09
-2.92E-09
5.83E-09
-1.02E-08
-3.80E-10
24 Hr
Anneal
60
-1.27E-09
-7.63E-09
-4.57E-09
3.27E-09
-2.86E-09
1.10E-10
-7.75E-09
1.24E-09
-3.84E-09
4.37E-09
-1.04E-08
-4.50E-10
168 Hr
Anneal
70
2.20E-10
-6.07E-09
-3.03E-09
3.14E-09
-1.39E-09
-2.40E-10
-6.45E-09
1.49E-09
-3.12E-09
4.91E-09
-1.06E-08
-5.90E-10
9.64E-10 4.64E-10 -1.46E-10 -6.18E-10 -1.98E-09 -2.61E-09 -1.43E-09
3.56E-09 3.64E-09 3.47E-09 3.78E-09 4.08E-09 4.05E-09 3.45E-09
1.07E-08 1.04E-08 9.36E-09 9.73E-09 9.21E-09 8.48E-09 8.04E-09
-8.81E-09 -9.51E-09 -9.65E-09 -1.10E-08 -1.32E-08 -1.37E-08 -1.09E-08
-1.10E-10
4.12E-09
1.12E-08
-1.14E-08
-7.00E-08
PASS
7.00E-08
PASS
-3.06E-10
4.14E-09
1.10E-08
-1.16E-08
-1.00E-07
PASS
1.00E-07
PASS
-3.70E-10
4.44E-09
1.18E-08
-1.25E-08
-1.00E-07
PASS
1.00E-07
PASS
-5.32E-10
4.43E-09
1.16E-08
-1.27E-08
-1.00E-07
PASS
1.00E-07
PASS
-2.10E-10
4.83E-09
1.30E-08
-1.35E-08
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
90
-1.17E-09
4.71E-09
1.17E-08
-1.41E-08
-1.00E-07
PASS
1.00E-07
PASS
-6.82E-10
4.34E-09
1.12E-08
-1.26E-08
-1.00E-07
PASS
1.00E-07
PASS
Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.40. Plot of Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
91
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.40. Raw data for Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current3 2 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
1.91E-09
-2.90E-09
-2.91E-09
-1.90E-10
2.12E-09
-2.44E-09
-1.22E-09
1.59E-09
2.40E-10
-2.16E-09
2.42E-09
1.39E-09
10
1.89E-09
-3.24E-09
-3.89E-09
-7.20E-10
2.55E-09
-2.25E-09
-1.56E-09
1.70E-09
8.00E-11
-2.13E-09
2.12E-09
-1.40E-10
Total Dose
20
1.69E-09
-3.80E-09
-4.56E-09
-4.70E-10
2.78E-09
-2.58E-09
-1.45E-09
1.80E-09
-2.50E-10
-2.35E-09
1.64E-09
-1.90E-10
(krad(Si))
30
1.32E-09
-4.47E-09
-5.11E-09
-1.15E-09
2.69E-09
-2.57E-09
-8.20E-10
2.02E-09
-3.50E-10
-2.55E-09
1.39E-09
-2.30E-10
50
-5.60E-10
-5.04E-09
-5.63E-09
-1.79E-09
2.09E-09
-2.79E-09
-1.90E-09
2.58E-09
-3.60E-10
-2.16E-09
1.27E-09
-1.20E-10
24 Hr
Anneal
60
-1.14E-09
-5.66E-09
-6.19E-09
-2.61E-09
1.57E-09
-3.43E-09
-3.00E-09
1.47E-09
-9.70E-10
-3.05E-09
1.07E-09
-1.50E-10
168 Hr
Anneal
70
-1.40E-10
-4.43E-09
-4.73E-09
-2.19E-09
9.40E-10
-3.03E-09
-2.56E-09
2.02E-09
-2.90E-10
-2.56E-09
9.30E-10
-2.50E-10
-3.94E-10 -6.82E-10 -8.72E-10 -1.34E-09 -2.19E-09 -2.81E-09 -2.11E-09
2.46E-09 2.91E-09 3.25E-09 3.44E-09 3.21E-09 3.22E-09 2.52E-09
6.36E-09 7.30E-09 8.04E-09 8.09E-09 6.60E-09 6.03E-09 4.80E-09
-7.15E-09 -8.66E-09 -9.78E-09 -1.08E-08 -1.10E-08 -1.16E-08 -9.02E-09
-7.98E-10
1.70E-09
3.85E-09
-5.45E-09
-7.00E-08
PASS
7.00E-08
PASS
-8.32E-10
1.69E-09
3.81E-09
-5.47E-09
-1.00E-07
PASS
1.00E-07
PASS
-9.66E-10
1.80E-09
3.96E-09
-5.89E-09
-1.00E-07
PASS
1.00E-07
PASS
-8.54E-10
1.89E-09
4.34E-09
-6.05E-09
-1.00E-07
PASS
1.00E-07
PASS
-9.26E-10
2.15E-09
4.98E-09
-6.83E-09
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
92
-1.80E-09
2.06E-09
3.86E-09
-7.46E-09
-1.00E-07
PASS
1.00E-07
PASS
-1.28E-09
2.13E-09
4.57E-09
-7.13E-09
-1.00E-07
PASS
1.00E-07
PASS
Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.41. Plot of Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
93
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.41. Raw data for Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current3 3 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-1.82E-09
-1.19E-09
-2.38E-09
5.34E-09
-5.30E-09
1.73E-09
-3.95E-09
-2.10E-10
2.70E-09
-5.02E-09
-1.00E-10
-6.94E-09
10
1.15E-09
2.61E-09
2.10E-10
7.81E-09
-2.59E-09
4.79E-09
-7.40E-10
2.98E-09
5.80E-09
-1.86E-09
3.16E-09
-4.92E-09
Total Dose
20
-7.00E-11
8.00E-10
-1.52E-09
6.34E-09
-4.17E-09
3.90E-09
-1.71E-09
2.11E-09
4.82E-09
-3.08E-09
1.94E-09
-5.85E-09
(krad(Si))
30
-1.53E-09
-6.90E-10
-2.40E-09
5.52E-09
-5.70E-09
3.27E-09
-1.74E-09
8.40E-10
4.37E-09
-3.78E-09
1.16E-09
-6.48E-09
50
-2.00E-09
-9.40E-10
-2.77E-09
5.17E-09
-6.68E-09
3.27E-09
-2.46E-09
1.61E-09
4.50E-09
-3.11E-09
1.35E-09
-6.19E-09
24 Hr
Anneal
60
-2.66E-09
-2.08E-09
-3.19E-09
5.11E-09
-7.18E-09
2.49E-09
-3.33E-09
3.00E-10
3.69E-09
-3.77E-09
1.20E-09
-6.36E-09
168 Hr
Anneal
70
-1.54E-09
-1.65E-09
-3.26E-09
5.62E-09
-5.31E-09
2.73E-09
-1.95E-09
1.25E-09
4.38E-09
-2.98E-09
9.30E-10
-6.50E-09
-1.07E-09 1.84E-09 2.76E-10 -9.60E-10 -1.44E-09 -2.00E-09 -1.23E-09
3.91E-09 3.84E-09 3.88E-09 4.09E-09 4.29E-09 4.45E-09 4.12E-09
9.66E-09 1.24E-08 1.09E-08 1.03E-08 1.03E-08 1.02E-08 1.01E-08
-1.18E-08 -8.69E-09 -1.04E-08 -1.22E-08 -1.32E-08 -1.42E-08 -1.25E-08
-9.50E-10
3.41E-09
8.41E-09
-1.03E-08
-7.00E-08
PASS
7.00E-08
PASS
2.19E-09
3.37E-09
1.14E-08
-7.04E-09
-1.00E-07
PASS
1.00E-07
PASS
1.21E-09
3.46E-09
1.07E-08
-8.29E-09
-1.00E-07
PASS
1.00E-07
PASS
5.92E-10
3.39E-09
9.90E-09
-8.71E-09
-1.00E-07
PASS
1.00E-07
PASS
7.62E-10
3.40E-09
1.01E-08
-8.57E-09
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
94
-1.24E-10
3.36E-09
9.09E-09
-9.33E-09
-1.00E-07
PASS
1.00E-07
PASS
6.86E-10
3.10E-09
9.20E-09
-7.82E-09
-1.00E-07
PASS
1.00E-07
PASS
Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-07
1.00E-07
5.00E-08
0.00E+00
-5.00E-08
-1.00E-07
-1.50E-07
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.42. Plot of Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
95
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.42. Raw data for Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current3 4 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
2.13E-09
-6.80E-10
1.42E-08
7.26E-09
-2.67E-09
4.25E-09
7.99E-09
1.01E-09
1.00E-08
2.66E-09
3.23E-09
-1.52E-09
10
-2.12E-09
-5.11E-09
9.81E-09
2.97E-09
-5.38E-09
7.40E-10
4.41E-09
-2.59E-09
6.64E-09
-5.10E-10
-2.00E-11
-6.16E-09
Total Dose
20
-3.68E-09
-7.10E-09
6.91E-09
6.30E-10
-6.95E-09
-9.60E-10
3.08E-09
-3.82E-09
5.70E-09
-1.93E-09
-1.49E-09
-7.27E-09
(krad(Si))
30
-4.90E-09
-7.68E-09
5.61E-09
-4.00E-10
-8.32E-09
-1.07E-09
2.67E-09
-4.75E-09
5.32E-09
-2.06E-09
-2.22E-09
-7.69E-09
50
-5.82E-09
-9.01E-09
4.22E-09
-2.09E-09
-8.61E-09
-1.16E-09
2.08E-09
-4.36E-09
4.70E-09
-3.32E-09
-2.74E-09
-8.36E-09
24 Hr
Anneal
60
-6.39E-09
-1.06E-08
3.60E-09
-1.89E-09
-9.16E-09
-2.20E-09
1.53E-09
-5.45E-09
3.64E-09
-3.80E-09
-2.80E-09
-8.54E-09
168 Hr
Anneal
70
-5.48E-09
-9.10E-09
5.05E-09
-1.24E-09
-9.57E-09
-1.38E-09
2.33E-09
-4.94E-09
5.01E-09
-3.27E-09
-3.09E-09
-8.45E-09
4.06E-09 3.40E-11 -2.04E-09 -3.14E-09 -4.26E-09 -4.88E-09 -4.07E-09
6.81E-09 6.41E-09 5.91E-09 5.80E-09 5.49E-09 5.78E-09 6.10E-09
2.27E-08 1.76E-08 1.42E-08 1.28E-08 1.08E-08 1.10E-08 1.27E-08
-1.46E-08 -1.76E-08 -1.82E-08 -1.90E-08 -1.93E-08 -2.07E-08 -2.08E-08
5.19E-09
3.75E-09
1.55E-08
-5.08E-09
-7.00E-08
PASS
7.00E-08
PASS
1.74E-09
3.74E-09
1.20E-08
-8.52E-09
-1.00E-07
PASS
1.00E-07
PASS
4.14E-10
3.88E-09
1.11E-08
-1.02E-08
-1.00E-07
PASS
1.00E-07
PASS
2.20E-11
3.98E-09
1.09E-08
-1.09E-08
-1.00E-07
PASS
1.00E-07
PASS
-4.12E-10
3.77E-09
9.93E-09
-1.08E-08
-1.00E-07
PASS
1.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
96
-1.26E-09
3.76E-09
9.07E-09
-1.16E-08
-1.00E-07
PASS
1.00E-07
PASS
-4.50E-10
4.08E-09
1.07E-08
-1.16E-08
-1.00E-07
PASS
1.00E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS3 1 15V (A)
@ VS=+/-15V, VCM=-15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.43. Plot of +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
97
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.43. Raw data for +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS3 1 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.48E-07
-3.67E-07
-3.73E-07
-3.84E-07
-3.72E-07
-3.81E-07
-3.64E-07
-3.62E-07
-3.68E-07
-3.66E-07
-3.48E-07
-3.58E-07
10
-3.58E-07
-3.80E-07
-3.86E-07
-3.98E-07
-3.86E-07
-3.82E-07
-3.69E-07
-3.67E-07
-3.72E-07
-3.69E-07
-3.45E-07
-3.59E-07
Total Dose (krad(Si))
20
30
-3.63E-07 -3.71E-07
-3.87E-07 -3.92E-07
-3.97E-07 -4.01E-07
-4.09E-07 -4.11E-07
-3.98E-07 -4.03E-07
-3.91E-07 -3.97E-07
-3.77E-07 -3.85E-07
-3.72E-07 -3.79E-07
-3.78E-07 -3.85E-07
-3.77E-07 -3.84E-07
-3.46E-07 -3.48E-07
-3.55E-07 -3.58E-07
50
-3.88E-07
-4.09E-07
-4.18E-07
-4.25E-07
-4.16E-07
-4.13E-07
-4.02E-07
-4.00E-07
-4.02E-07
-4.00E-07
-3.51E-07
-3.55E-07
24 Hr
Anneal
60
-3.87E-07
-4.10E-07
-4.18E-07
-4.27E-07
-4.15E-07
-4.13E-07
-4.03E-07
-3.99E-07
-4.02E-07
-4.02E-07
-3.52E-07
-3.59E-07
168 Hr
Anneal
70
-3.73E-07
-3.91E-07
-3.99E-07
-4.09E-07
-3.99E-07
-3.98E-07
-3.84E-07
-3.83E-07
-3.86E-07
-3.85E-07
-3.52E-07
-3.61E-07
-3.69E-07 -3.82E-07 -3.91E-07 -3.96E-07 -4.11E-07 -4.12E-07 -3.94E-07
1.34E-08 1.45E-08 1.74E-08 1.54E-08 1.40E-08 1.49E-08 1.35E-08
-3.32E-07 -3.42E-07 -3.43E-07 -3.53E-07 -3.73E-07 -3.71E-07 -3.57E-07
-4.05E-07 -4.21E-07 -4.38E-07 -4.38E-07 -4.50E-07 -4.53E-07 -4.31E-07
-3.68E-07
7.49E-09
-3.48E-07
-3.89E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.72E-07
6.09E-09
-3.55E-07
-3.88E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.79E-07
7.01E-09
-3.60E-07
-3.98E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.86E-07
6.70E-09
-3.68E-07
-4.04E-07
-8.15E-07
PASS
8.15E-07
PASS
-4.03E-07
5.62E-09
-3.88E-07
-4.19E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
98
-4.03E-07
5.24E-09
-3.89E-07
-4.18E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.87E-07
6.10E-09
-3.70E-07
-4.04E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS3 2 15V (A)
@ VS=+/-15V, VCM=-15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.44. Plot of +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
99
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.44. Raw data for +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS3 2 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.38E-07
-3.88E-07
-3.69E-07
-3.71E-07
-3.55E-07
-3.70E-07
-3.66E-07
-3.58E-07
-3.55E-07
-3.62E-07
-3.69E-07
-3.66E-07
10
-3.50E-07
-4.00E-07
-3.84E-07
-3.84E-07
-3.69E-07
-3.72E-07
-3.68E-07
-3.61E-07
-3.58E-07
-3.65E-07
-3.64E-07
-3.70E-07
Total Dose (krad(Si))
20
30
-3.56E-07 -3.64E-07
-4.08E-07 -4.13E-07
-3.95E-07 -3.98E-07
-3.94E-07 -3.98E-07
-3.79E-07 -3.83E-07
-3.81E-07 -3.88E-07
-3.78E-07 -3.84E-07
-3.68E-07 -3.76E-07
-3.66E-07 -3.70E-07
-3.73E-07 -3.79E-07
-3.67E-07 -3.67E-07
-3.66E-07 -3.67E-07
50
-3.81E-07
-4.27E-07
-4.13E-07
-4.11E-07
-3.97E-07
-4.05E-07
-4.02E-07
-3.96E-07
-3.88E-07
-3.99E-07
-3.71E-07
-3.66E-07
24 Hr
Anneal
60
-3.82E-07
-4.28E-07
-4.15E-07
-4.14E-07
-3.98E-07
-4.05E-07
-4.01E-07
-3.95E-07
-3.88E-07
-4.00E-07
-3.72E-07
-3.68E-07
168 Hr
Anneal
70
-3.65E-07
-4.09E-07
-3.95E-07
-3.96E-07
-3.80E-07
-3.89E-07
-3.85E-07
-3.78E-07
-3.73E-07
-3.81E-07
-3.71E-07
-3.71E-07
-3.64E-07 -3.77E-07 -3.86E-07 -3.91E-07 -4.06E-07 -4.07E-07 -3.89E-07
1.87E-08 1.89E-08 1.97E-08 1.84E-08 1.72E-08 1.78E-08 1.69E-08
-3.13E-07 -3.26E-07 -3.32E-07 -3.41E-07 -3.58E-07 -3.59E-07 -3.43E-07
-4.16E-07 -4.29E-07 -4.40E-07 -4.42E-07 -4.53E-07 -4.56E-07 -4.35E-07
-3.62E-07
5.97E-09
-3.45E-07
-3.78E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.65E-07
5.53E-09
-3.50E-07
-3.80E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.73E-07
6.61E-09
-3.55E-07
-3.91E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.80E-07
6.79E-09
-3.61E-07
-3.98E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.98E-07
6.36E-09
-3.80E-07
-4.15E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
100
-3.98E-07
6.42E-09
-3.80E-07
-4.15E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.81E-07
6.26E-09
-3.64E-07
-3.98E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS3 3 15V (A)
@ VS=+/-15V, VCM=-15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.45. Plot of +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
101
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.45. Raw data for +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS3 3 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.46E-07
-3.86E-07
-3.79E-07
-3.73E-07
-3.60E-07
-3.74E-07
-3.70E-07
-3.62E-07
-3.54E-07
-3.68E-07
-3.74E-07
-3.83E-07
10
-3.51E-07
-3.92E-07
-3.88E-07
-3.81E-07
-3.69E-07
-3.72E-07
-3.66E-07
-3.60E-07
-3.51E-07
-3.64E-07
-3.64E-07
-3.79E-07
Total Dose (krad(Si))
20
30
-3.56E-07 -3.64E-07
-4.02E-07 -4.06E-07
-3.97E-07 -4.02E-07
-3.92E-07 -3.95E-07
-3.79E-07 -3.84E-07
-3.78E-07 -3.88E-07
-3.76E-07 -3.81E-07
-3.68E-07 -3.76E-07
-3.59E-07 -3.65E-07
-3.73E-07 -3.81E-07
-3.66E-07 -3.68E-07
-3.77E-07 -3.77E-07
50
-3.79E-07
-4.19E-07
-4.17E-07
-4.08E-07
-3.98E-07
-4.04E-07
-3.97E-07
-3.92E-07
-3.82E-07
-3.97E-07
-3.71E-07
-3.74E-07
24 Hr
Anneal
60
-3.80E-07
-4.22E-07
-4.17E-07
-4.11E-07
-3.98E-07
-4.03E-07
-3.98E-07
-3.93E-07
-3.82E-07
-3.98E-07
-3.72E-07
-3.78E-07
168 Hr
Anneal
70
-3.65E-07
-4.04E-07
-3.99E-07
-3.92E-07
-3.81E-07
-3.90E-07
-3.83E-07
-3.77E-07
-3.66E-07
-3.82E-07
-3.72E-07
-3.81E-07
-3.69E-07 -3.76E-07 -3.85E-07 -3.90E-07 -4.04E-07 -4.06E-07 -3.88E-07
1.59E-08 1.67E-08 1.84E-08 1.70E-08 1.63E-08 1.66E-08 1.58E-08
-3.25E-07 -3.30E-07 -3.35E-07 -3.43E-07 -3.60E-07 -3.60E-07 -3.45E-07
-4.12E-07 -4.22E-07 -4.35E-07 -4.37E-07 -4.49E-07 -4.51E-07 -4.31E-07
-3.65E-07
7.65E-09
-3.44E-07
-3.86E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.63E-07
7.61E-09
-3.42E-07
-3.83E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.71E-07
7.74E-09
-3.50E-07
-3.92E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.78E-07
8.28E-09
-3.55E-07
-4.01E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.95E-07
8.17E-09
-3.72E-07
-4.17E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
102
-3.95E-07
7.97E-09
-3.73E-07
-4.17E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.79E-07
8.96E-09
-3.55E-07
-4.04E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
+Input Bias Current BIAS3 4 15V (A)
@ VS=+/-15V, VCM=-15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.46. Plot of +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
103
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.46. Raw data for +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS3 4 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.50E-07
-3.66E-07
-3.62E-07
-3.81E-07
-3.74E-07
-3.74E-07
-3.60E-07
-3.66E-07
-3.68E-07
-3.66E-07
-3.35E-07
-3.55E-07
10
-3.60E-07
-3.77E-07
-3.78E-07
-3.95E-07
-3.88E-07
-3.76E-07
-3.63E-07
-3.69E-07
-3.72E-07
-3.70E-07
-3.34E-07
-3.57E-07
Total Dose (krad(Si))
20
30
-3.68E-07 -3.74E-07
-3.87E-07 -3.93E-07
-3.88E-07 -3.92E-07
-4.06E-07 -4.08E-07
-3.99E-07 -4.03E-07
-3.84E-07 -3.90E-07
-3.73E-07 -3.80E-07
-3.77E-07 -3.86E-07
-3.78E-07 -3.84E-07
-3.76E-07 -3.83E-07
-3.35E-07 -3.35E-07
-3.54E-07 -3.55E-07
50
-3.91E-07
-4.08E-07
-4.08E-07
-4.24E-07
-4.18E-07
-4.06E-07
-3.99E-07
-4.05E-07
-4.03E-07
-4.01E-07
-3.38E-07
-3.54E-07
24 Hr
Anneal
60
-3.91E-07
-4.10E-07
-4.09E-07
-4.25E-07
-4.17E-07
-4.05E-07
-3.98E-07
-4.04E-07
-4.03E-07
-4.03E-07
-3.39E-07
-3.57E-07
168 Hr
Anneal
70
-3.74E-07
-3.89E-07
-3.90E-07
-4.06E-07
-3.99E-07
-3.92E-07
-3.80E-07
-3.88E-07
-3.87E-07
-3.87E-07
-3.38E-07
-3.60E-07
-3.67E-07 -3.80E-07 -3.89E-07 -3.94E-07 -4.10E-07 -4.10E-07 -3.92E-07
1.17E-08 1.32E-08 1.45E-08 1.31E-08 1.26E-08 1.27E-08 1.21E-08
-3.34E-07 -3.43E-07 -3.50E-07 -3.58E-07 -3.75E-07 -3.75E-07 -3.58E-07
-3.99E-07 -4.16E-07 -4.29E-07 -4.30E-07 -4.44E-07 -4.45E-07 -4.25E-07
-3.67E-07
4.96E-09
-3.53E-07
-3.80E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.70E-07
4.77E-09
-3.57E-07
-3.83E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.78E-07
4.31E-09
-3.66E-07
-3.90E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.85E-07
3.91E-09
-3.74E-07
-3.95E-07
-8.15E-07
PASS
8.15E-07
PASS
-4.03E-07
3.08E-09
-3.94E-07
-4.11E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
104
-4.02E-07
2.70E-09
-3.95E-07
-4.10E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.87E-07
4.27E-09
-3.75E-07
-3.98E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS3 1 15V (A)
@ VS=+/-15V, VCM=-15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.47. Plot of -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
105
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.47. Raw data for -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS3 1 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.51E-07
-3.62E-07
-3.72E-07
-3.89E-07
-3.74E-07
-3.78E-07
-3.59E-07
-3.65E-07
-3.65E-07
-3.71E-07
-3.35E-07
-3.60E-07
10
-3.60E-07
-3.74E-07
-3.88E-07
-4.04E-07
-3.87E-07
-3.83E-07
-3.61E-07
-3.67E-07
-3.69E-07
-3.75E-07
-3.33E-07
-3.58E-07
Total Dose (krad(Si))
20
30
-3.64E-07 -3.72E-07
-3.83E-07 -3.87E-07
-3.95E-07 -3.98E-07
-4.10E-07 -4.16E-07
-3.96E-07 -4.00E-07
-3.89E-07 -3.98E-07
-3.71E-07 -3.76E-07
-3.74E-07 -3.81E-07
-3.74E-07 -3.81E-07
-3.81E-07 -3.87E-07
-3.34E-07 -3.33E-07
-3.55E-07 -3.57E-07
50
-3.87E-07
-4.02E-07
-4.14E-07
-4.29E-07
-4.15E-07
-4.13E-07
-3.94E-07
-4.02E-07
-4.00E-07
-4.05E-07
-3.36E-07
-3.54E-07
24 Hr
Anneal
60
-3.85E-07
-4.02E-07
-4.12E-07
-4.29E-07
-4.14E-07
-4.12E-07
-3.94E-07
-4.00E-07
-3.98E-07
-4.05E-07
-3.37E-07
-3.58E-07
168 Hr
Anneal
70
-3.74E-07
-3.85E-07
-3.96E-07
-4.11E-07
-3.97E-07
-3.97E-07
-3.78E-07
-3.86E-07
-3.83E-07
-3.90E-07
-3.36E-07
-3.61E-07
-3.70E-07 -3.83E-07 -3.90E-07 -3.95E-07 -4.09E-07 -4.08E-07 -3.92E-07
1.44E-08 1.67E-08 1.71E-08 1.62E-08 1.57E-08 1.62E-08 1.40E-08
-3.30E-07 -3.37E-07 -3.43E-07 -3.50E-07 -3.66E-07 -3.64E-07 -3.54E-07
-4.09E-07 -4.28E-07 -4.37E-07 -4.39E-07 -4.52E-07 -4.53E-07 -4.31E-07
-3.68E-07
7.20E-09
-3.48E-07
-3.88E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.71E-07
8.12E-09
-3.49E-07
-3.93E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.78E-07
7.34E-09
-3.58E-07
-3.98E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.85E-07
8.24E-09
-3.62E-07
-4.07E-07
-8.15E-07
PASS
8.15E-07
PASS
-4.03E-07
7.01E-09
-3.84E-07
-4.22E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
106
-4.02E-07
6.91E-09
-3.83E-07
-4.21E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.87E-07
7.30E-09
-3.67E-07
-4.07E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS3 2 15V (A)
@ VS=+/-15V, VCM=-15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.48. Plot of -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
107
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.48. Raw data for -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS3 2 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.40E-07
-3.86E-07
-3.68E-07
-3.72E-07
-3.59E-07
-3.69E-07
-3.64E-07
-3.59E-07
-3.57E-07
-3.60E-07
-3.73E-07
-3.69E-07
10
-3.54E-07
-3.98E-07
-3.83E-07
-3.84E-07
-3.73E-07
-3.72E-07
-3.67E-07
-3.64E-07
-3.61E-07
-3.63E-07
-3.69E-07
-3.70E-07
Total Dose (krad(Si))
20
30
-3.60E-07 -3.66E-07
-4.05E-07 -4.09E-07
-3.90E-07 -3.96E-07
-3.94E-07 -3.99E-07
-3.83E-07 -3.87E-07
-3.79E-07 -3.87E-07
-3.76E-07 -3.83E-07
-3.71E-07 -3.79E-07
-3.65E-07 -3.72E-07
-3.71E-07 -3.77E-07
-3.69E-07 -3.71E-07
-3.67E-07 -3.68E-07
50
-3.84E-07
-4.23E-07
-4.07E-07
-4.10E-07
-4.03E-07
-4.03E-07
-4.02E-07
-3.98E-07
-3.89E-07
-3.96E-07
-3.74E-07
-3.66E-07
24 Hr
Anneal
60
-3.83E-07
-4.24E-07
-4.08E-07
-4.13E-07
-4.00E-07
-4.03E-07
-4.00E-07
-3.97E-07
-3.88E-07
-3.97E-07
-3.74E-07
-3.69E-07
168 Hr
Anneal
70
-3.67E-07
-4.06E-07
-3.92E-07
-3.94E-07
-3.82E-07
-3.88E-07
-3.83E-07
-3.82E-07
-3.74E-07
-3.80E-07
-3.72E-07
-3.74E-07
-3.65E-07 -3.78E-07 -3.86E-07 -3.91E-07 -4.05E-07 -4.06E-07 -3.88E-07
1.72E-08 1.63E-08 1.65E-08 1.60E-08 1.42E-08 1.52E-08 1.46E-08
-3.18E-07 -3.33E-07 -3.41E-07 -3.47E-07 -3.66E-07 -3.64E-07 -3.48E-07
-4.12E-07 -4.23E-07 -4.32E-07 -4.35E-07 -4.44E-07 -4.47E-07 -4.28E-07
-3.62E-07
4.70E-09
-3.49E-07
-3.75E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.66E-07
4.54E-09
-3.53E-07
-3.78E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.73E-07
5.49E-09
-3.57E-07
-3.88E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.80E-07
5.68E-09
-3.64E-07
-3.95E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.98E-07
5.44E-09
-3.83E-07
-4.13E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
108
-3.97E-07
5.36E-09
-3.82E-07
-4.12E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.81E-07
5.27E-09
-3.67E-07
-3.96E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS3 3 15V (A)
@ VS=+/-15V, VCM=-15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.49. Plot of -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
109
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.49. Raw data for -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS3 3 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.38E-07
-3.80E-07
-3.71E-07
-3.73E-07
-3.51E-07
-3.71E-07
-3.62E-07
-3.58E-07
-3.54E-07
-3.58E-07
-3.69E-07
-3.71E-07
10
-3.50E-07
-3.94E-07
-3.86E-07
-3.85E-07
-3.65E-07
-3.75E-07
-3.65E-07
-3.62E-07
-3.57E-07
-3.61E-07
-3.67E-07
-3.71E-07
Total Dose (krad(Si))
20
30
-3.56E-07 -3.62E-07
-4.00E-07 -4.04E-07
-3.93E-07 -3.98E-07
-3.97E-07 -3.99E-07
-3.73E-07 -3.77E-07
-3.81E-07 -3.90E-07
-3.72E-07 -3.79E-07
-3.69E-07 -3.74E-07
-3.61E-07 -3.68E-07
-3.68E-07 -3.75E-07
-3.67E-07 -3.67E-07
-3.68E-07 -3.70E-07
50
-3.77E-07
-4.17E-07
-4.12E-07
-4.13E-07
-3.90E-07
-4.06E-07
-3.96E-07
-3.92E-07
-3.86E-07
-3.94E-07
-3.72E-07
-3.68E-07
24 Hr
Anneal
60
-3.76E-07
-4.20E-07
-4.14E-07
-4.15E-07
-3.90E-07
-4.04E-07
-3.94E-07
-3.92E-07
-3.84E-07
-3.94E-07
-3.73E-07
-3.71E-07
168 Hr
Anneal
70
-3.63E-07
-4.00E-07
-3.94E-07
-3.96E-07
-3.76E-07
-3.91E-07
-3.80E-07
-3.78E-07
-3.70E-07
-3.79E-07
-3.72E-07
-3.72E-07
-3.63E-07 -3.76E-07 -3.84E-07 -3.88E-07 -4.02E-07 -4.03E-07 -3.86E-07
1.76E-08 1.79E-08 1.89E-08 1.79E-08 1.72E-08 1.88E-08 1.59E-08
-3.14E-07 -3.27E-07 -3.32E-07 -3.39E-07 -3.55E-07 -3.51E-07 -3.42E-07
-4.11E-07 -4.25E-07 -4.36E-07 -4.37E-07 -4.49E-07 -4.54E-07 -4.30E-07
-3.60E-07
6.75E-09
-3.42E-07
-3.79E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.64E-07
6.96E-09
-3.45E-07
-3.83E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.70E-07
7.17E-09
-3.51E-07
-3.90E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.77E-07
7.83E-09
-3.56E-07
-3.99E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.95E-07
7.47E-09
-3.74E-07
-4.15E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
110
-3.94E-07
6.96E-09
-3.75E-07
-4.13E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.80E-07
7.35E-09
-3.59E-07
-4.00E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
-Input Bias Current BIAS3 4 15V (A)
@ VS=+/-15V, VCM=-15V
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.50. Plot of -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
111
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.50. Raw data for -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS3 4 15V (A)
@ VS=+/-15V, VCM=-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.48E-07
-3.61E-07
-3.74E-07
-3.85E-07
-3.68E-07
-3.73E-07
-3.63E-07
-3.63E-07
-3.75E-07
-3.66E-07
-3.34E-07
-3.51E-07
10
-3.57E-07
-3.72E-07
-3.87E-07
-3.96E-07
-3.81E-07
-3.74E-07
-3.66E-07
-3.67E-07
-3.78E-07
-3.69E-07
-3.32E-07
-3.50E-07
Total Dose (krad(Si))
20
30
-3.62E-07 -3.70E-07
-3.81E-07 -3.86E-07
-3.94E-07 -3.98E-07
-4.05E-07 -4.09E-07
-3.92E-07 -3.95E-07
-3.84E-07 -3.90E-07
-3.76E-07 -3.82E-07
-3.73E-07 -3.81E-07
-3.85E-07 -3.91E-07
-3.75E-07 -3.82E-07
-3.33E-07 -3.32E-07
-3.46E-07 -3.49E-07
50
-3.88E-07
-4.00E-07
-4.12E-07
-4.25E-07
-4.11E-07
-4.06E-07
-4.01E-07
-4.00E-07
-4.09E-07
-3.99E-07
-3.35E-07
-3.47E-07
24 Hr
Anneal
60
-3.86E-07
-4.00E-07
-4.12E-07
-4.25E-07
-4.09E-07
-4.04E-07
-4.01E-07
-3.99E-07
-4.07E-07
-4.00E-07
-3.36E-07
-3.50E-07
168 Hr
Anneal
70
-3.70E-07
-3.82E-07
-3.96E-07
-4.05E-07
-3.91E-07
-3.90E-07
-3.82E-07
-3.84E-07
-3.93E-07
-3.84E-07
-3.35E-07
-3.52E-07
-3.67E-07 -3.79E-07 -3.87E-07 -3.92E-07 -4.07E-07 -4.06E-07 -3.89E-07
1.38E-08 1.47E-08 1.62E-08 1.46E-08 1.39E-08 1.48E-08 1.32E-08
-3.29E-07 -3.38E-07 -3.43E-07 -3.52E-07 -3.69E-07 -3.66E-07 -3.53E-07
-4.05E-07 -4.19E-07 -4.31E-07 -4.32E-07 -4.45E-07 -4.47E-07 -4.25E-07
-3.68E-07
5.86E-09
-3.52E-07
-3.84E-07
-7.15E-07
PASS
7.15E-07
PASS
-3.71E-07
4.90E-09
-3.57E-07
-3.84E-07
-7.65E-07
PASS
7.65E-07
PASS
-3.79E-07
5.32E-09
-3.64E-07
-3.93E-07
-8.15E-07
PASS
8.15E-07
PASS
-3.85E-07
5.01E-09
-3.71E-07
-3.99E-07
-8.15E-07
PASS
8.15E-07
PASS
-4.03E-07
4.12E-09
-3.92E-07
-4.14E-07
-8.65E-07
PASS
8.65E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
112
-4.02E-07
3.37E-09
-3.93E-07
-4.11E-07
-8.65E-07
PASS
8.65E-07
PASS
-3.87E-07
4.78E-09
-3.74E-07
-4.00E-07
-8.65E-07
PASS
8.65E-07
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High1 1 15V (V)
@ VS=+/-15V IL=0mA
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.51. Plot of Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
113
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.51. Raw data for Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High1 1 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=0mA
Device
0
10
20
30
50
60
70
557 6.22E-03 6.53E-03 6.42E-03 6.60E-03 6.56E-03 6.37E-03 6.50E-03
563 6.24E-03 6.71E-03 6.84E-03 6.62E-03 6.79E-03 6.87E-03 6.67E-03
564 6.44E-03 6.45E-03 6.77E-03 7.10E-03 6.86E-03 6.87E-03 6.70E-03
567 6.41E-03 6.77E-03 6.77E-03 6.87E-03 7.00E-03 7.01E-03 6.77E-03
569 6.51E-03 6.46E-03 6.72E-03 6.51E-03 6.69E-03 6.80E-03 6.47E-03
570 6.27E-03 6.53E-03 6.55E-03 6.72E-03 7.10E-03 6.75E-03 6.69E-03
571 6.30E-03 6.41E-03 6.66E-03 6.41E-03 7.01E-03 6.67E-03 6.54E-03
572 6.51E-03 6.60E-03 6.60E-03 6.53E-03 6.83E-03 6.75E-03 6.62E-03
573 6.63E-03 6.71E-03 6.89E-03 6.87E-03 6.90E-03 7.01E-03 6.59E-03
574 6.29E-03 6.21E-03 6.49E-03 6.30E-03 6.54E-03 6.53E-03 6.32E-03
584 6.15E-03 6.41E-03 6.47E-03 6.21E-03 6.34E-03 6.40E-03 6.27E-03
585 6.14E-03 6.39E-03 6.40E-03 6.50E-03 6.85E-03 6.40E-03 6.27E-03
Biased Statistics
Average Biased
6.36E-03 6.58E-03 6.70E-03 6.74E-03 6.78E-03 6.78E-03 6.62E-03
Std Dev Biased
1.28E-04 1.47E-04 1.64E-04 2.42E-04 1.67E-04 2.44E-04 1.31E-04
Ps90%/90% (+KTL) Biased
6.71E-03 6.99E-03 7.15E-03 7.40E-03 7.24E-03 7.45E-03 6.98E-03
Ps90%/90% (-KTL) Biased
6.01E-03 6.18E-03 6.25E-03 6.08E-03 6.32E-03 6.12E-03 6.26E-03
Un-Biased Statistics
Average Un-Biased
6.40E-03 6.49E-03 6.64E-03 6.57E-03 6.88E-03 6.74E-03 6.55E-03
Std Dev Un-Biased
1.61E-04 1.92E-04 1.54E-04 2.30E-04 2.14E-04 1.75E-04 1.41E-04
Ps90%/90% (+KTL) Un-Biased
6.84E-03 7.02E-03 7.06E-03 7.20E-03 7.46E-03 7.22E-03 6.94E-03
Ps90%/90% (-KTL) Un-Biased
5.96E-03 5.97E-03 6.22E-03 5.93E-03 6.29E-03 6.26E-03 6.17E-03
Specification MAX
1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
114
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High1 2 15V (V)
@ VS=+/-15V IL=0mA
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.52. Plot of Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
115
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.52. Raw data for Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High1 2 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=0mA
Device
0
10
20
30
50
60
70
557 6.19E-03 6.48E-03 6.55E-03 6.70E-03 6.47E-03 6.42E-03 6.50E-03
563 6.68E-03 7.02E-03 7.16E-03 6.88E-03 7.20E-03 7.12E-03 7.09E-03
564 6.73E-03 6.78E-03 7.14E-03 7.19E-03 7.01E-03 7.12E-03 6.87E-03
567 6.52E-03 7.03E-03 6.98E-03 6.90E-03 7.13E-03 7.14E-03 6.87E-03
569 6.44E-03 6.65E-03 6.74E-03 6.78E-03 7.00E-03 6.85E-03 6.64E-03
570 6.52E-03 6.80E-03 6.81E-03 6.62E-03 7.15E-03 6.87E-03 6.72E-03
571 6.49E-03 6.45E-03 6.64E-03 6.50E-03 7.11E-03 6.77E-03 6.57E-03
572 6.51E-03 6.56E-03 6.62E-03 6.60E-03 6.85E-03 6.69E-03 6.65E-03
573 6.64E-03 6.87E-03 7.03E-03 6.73E-03 7.13E-03 7.11E-03 6.87E-03
574 6.37E-03 6.38E-03 6.74E-03 6.46E-03 6.61E-03 6.57E-03 6.54E-03
584 6.69E-03 6.95E-03 6.86E-03 6.65E-03 6.90E-03 6.70E-03 6.67E-03
585 6.59E-03 6.85E-03 6.87E-03 6.82E-03 7.08E-03 6.79E-03 6.62E-03
Biased Statistics
Average Biased
6.51E-03 6.79E-03 6.91E-03 6.89E-03 6.96E-03 6.93E-03 6.79E-03
Std Dev Biased
2.15E-04 2.38E-04 2.64E-04 1.86E-04 2.88E-04 3.09E-04 2.29E-04
Ps90%/90% (+KTL) Biased
7.10E-03 7.44E-03 7.64E-03 7.40E-03 7.75E-03 7.78E-03 7.42E-03
Ps90%/90% (-KTL) Biased
5.92E-03 6.14E-03 6.19E-03 6.38E-03 6.17E-03 6.08E-03 6.17E-03
Un-Biased Statistics
Average Un-Biased
6.51E-03 6.61E-03 6.77E-03 6.58E-03 6.97E-03 6.80E-03 6.67E-03
Std Dev Un-Biased
9.61E-05 2.15E-04 1.65E-04 1.06E-04 2.35E-04 2.04E-04 1.32E-04
Ps90%/90% (+KTL) Un-Biased
6.77E-03 7.20E-03 7.22E-03 6.87E-03 7.62E-03 7.36E-03 7.03E-03
Ps90%/90% (-KTL) Un-Biased
6.24E-03 6.02E-03 6.31E-03 6.29E-03 6.32E-03 6.24E-03 6.31E-03
Specification MAX
1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
116
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High1 3 15V (V)
@ VS=+/-15V IL=0mA
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.53. Plot of Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
117
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.53. Raw data for Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High1 3 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=0mA
Device
0
10
20
30
50
60
70
557 6.32E-03 6.43E-03 6.44E-03 6.65E-03 6.54E-03 6.55E-03 6.43E-03
563 6.64E-03 7.22E-03 7.19E-03 6.97E-03 7.23E-03 7.33E-03 7.14E-03
564 6.78E-03 6.85E-03 7.03E-03 7.22E-03 7.05E-03 7.04E-03 6.99E-03
567 6.71E-03 6.83E-03 7.09E-03 6.82E-03 7.13E-03 7.06E-03 6.94E-03
569 6.56E-03 6.75E-03 6.86E-03 6.75E-03 6.91E-03 6.85E-03 6.64E-03
570 6.78E-03 6.75E-03 6.66E-03 6.77E-03 7.11E-03 6.85E-03 6.99E-03
571 6.52E-03 6.50E-03 6.55E-03 6.60E-03 7.10E-03 6.67E-03 6.67E-03
572 6.54E-03 6.61E-03 6.69E-03 6.62E-03 6.85E-03 6.69E-03 6.55E-03
573 6.66E-03 6.87E-03 7.01E-03 7.00E-03 7.13E-03 7.21E-03 6.87E-03
574 6.49E-03 6.48E-03 6.71E-03 6.48E-03 6.56E-03 6.48E-03 6.50E-03
584 6.74E-03 6.85E-03 7.01E-03 6.67E-03 6.83E-03 6.75E-03 6.79E-03
585 6.84E-03 6.97E-03 6.81E-03 6.85E-03 7.15E-03 6.69E-03 6.74E-03
Biased Statistics
Average Biased
6.60E-03 6.82E-03 6.92E-03 6.88E-03 6.97E-03 6.97E-03 6.83E-03
Std Dev Biased
1.78E-04 2.82E-04 2.95E-04 2.22E-04 2.68E-04 2.89E-04 2.87E-04
Ps90%/90% (+KTL) Biased
7.09E-03 7.59E-03 7.73E-03 7.49E-03 7.71E-03 7.76E-03 7.62E-03
Ps90%/90% (-KTL) Biased
6.12E-03 6.04E-03 6.11E-03 6.27E-03 6.24E-03 6.17E-03 6.04E-03
Un-Biased Statistics
Average Un-Biased
6.60E-03 6.64E-03 6.72E-03 6.69E-03 6.95E-03 6.78E-03 6.72E-03
Std Dev Un-Biased
1.20E-04 1.67E-04 1.71E-04 2.00E-04 2.46E-04 2.74E-04 2.09E-04
Ps90%/90% (+KTL) Un-Biased
6.93E-03 7.10E-03 7.19E-03 7.24E-03 7.63E-03 7.53E-03 7.29E-03
Ps90%/90% (-KTL) Un-Biased
6.27E-03 6.19E-03 6.25E-03 6.15E-03 6.27E-03 6.03E-03 6.14E-03
Specification MAX
1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
118
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High1 4 15V (V)
@ VS=+/-15V IL=0mA
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.54. Plot of Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
119
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.54. Raw data for Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High1 4 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=0mA
Device
0
10
20
30
50
60
70
557 6.31E-03 6.65E-03 6.72E-03 6.75E-03 6.73E-03 6.58E-03 6.62E-03
563 6.64E-03 6.92E-03 6.91E-03 6.63E-03 6.95E-03 7.01E-03 7.01E-03
564 6.78E-03 6.85E-03 7.06E-03 7.17E-03 7.17E-03 7.14E-03 7.06E-03
567 6.83E-03 6.92E-03 7.06E-03 7.00E-03 6.93E-03 7.06E-03 6.86E-03
569 6.56E-03 6.73E-03 6.79E-03 6.77E-03 7.01E-03 6.85E-03 6.77E-03
570 6.66E-03 6.63E-03 6.84E-03 6.65E-03 7.17E-03 6.79E-03 6.92E-03
571 6.61E-03 6.48E-03 6.52E-03 6.58E-03 7.08E-03 6.80E-03 6.75E-03
572 6.59E-03 6.75E-03 6.84E-03 6.94E-03 7.03E-03 6.79E-03 6.81E-03
573 6.81E-03 6.80E-03 7.06E-03 6.99E-03 7.15E-03 7.19E-03 6.84E-03
574 6.63E-03 6.53E-03 6.69E-03 6.65E-03 6.71E-03 6.72E-03 6.67E-03
584 6.56E-03 6.65E-03 6.60E-03 6.51E-03 6.56E-03 6.48E-03 6.35E-03
585 6.46E-03 6.53E-03 6.47E-03 6.50E-03 6.80E-03 6.67E-03 6.40E-03
Biased Statistics
Average Biased
6.62E-03 6.81E-03 6.91E-03 6.86E-03 6.96E-03 6.93E-03 6.86E-03
Std Dev Biased
2.06E-04 1.20E-04 1.54E-04 2.17E-04 1.58E-04 2.22E-04 1.79E-04
Ps90%/90% (+KTL) Biased
7.19E-03 7.14E-03 7.33E-03 7.46E-03 7.39E-03 7.54E-03 7.35E-03
Ps90%/90% (-KTL) Biased
6.06E-03 6.48E-03 6.48E-03 6.27E-03 6.52E-03 6.32E-03 6.37E-03
Un-Biased Statistics
Average Un-Biased
6.66E-03 6.64E-03 6.79E-03 6.76E-03 7.03E-03 6.86E-03 6.80E-03
Std Dev Un-Biased
8.77E-05 1.37E-04 2.00E-04 1.88E-04 1.86E-04 1.88E-04 9.42E-05
Ps90%/90% (+KTL) Un-Biased
6.90E-03 7.01E-03 7.34E-03 7.28E-03 7.54E-03 7.37E-03 7.06E-03
Ps90%/90% (-KTL) Un-Biased
6.42E-03 6.26E-03 6.24E-03 6.25E-03 6.52E-03 6.34E-03 6.54E-03
Specification MAX
1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
120
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High2 1 15V (V)
@ VS=+/-15V IL=1mA
1.60E-01
1.40E-01
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.55. Plot of Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
121
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.55. Raw data for Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High2 1 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=1mA
Device
0
10
20
30
50
60
70
557 7.01E-02 7.05E-02 7.07E-02 7.11E-02 7.12E-02 7.10E-02 7.10E-02
563 7.44E-02 7.51E-02 7.54E-02 7.54E-02 7.54E-02 7.57E-02 7.56E-02
564 7.55E-02 7.61E-02 7.66E-02 7.73E-02 7.69E-02 7.70E-02 7.68E-02
567 7.54E-02 7.61E-02 7.66E-02 7.69E-02 7.67E-02 7.68E-02 7.65E-02
569 7.37E-02 7.45E-02 7.49E-02 7.50E-02 7.50E-02 7.49E-02 7.48E-02
570 7.47E-02 7.47E-02 7.51E-02 7.53E-02 7.59E-02 7.55E-02 7.52E-02
571 7.41E-02 7.41E-02 7.45E-02 7.48E-02 7.57E-02 7.50E-02 7.49E-02
572 7.42E-02 7.44E-02 7.51E-02 7.52E-02 7.56E-02 7.50E-02 7.51E-02
573 7.55E-02 7.60E-02 7.62E-02 7.63E-02 7.66E-02 7.67E-02 7.61E-02
574 7.32E-02 7.30E-02 7.37E-02 7.38E-02 7.39E-02 7.38E-02 7.37E-02
584 7.10E-02 7.14E-02 7.13E-02 7.10E-02 7.09E-02 7.07E-02 7.07E-02
585 7.09E-02 7.08E-02 7.15E-02 7.10E-02 7.11E-02 7.04E-02 7.07E-02
Biased Statistics
Average Biased
7.38E-02 7.44E-02 7.48E-02 7.51E-02 7.51E-02 7.51E-02 7.50E-02
Std Dev Biased
2.21E-03 2.29E-03 2.45E-03 2.45E-03 2.27E-03 2.44E-03 2.32E-03
Ps90%/90% (+KTL) Biased
7.99E-02 8.07E-02 8.16E-02 8.18E-02 8.13E-02 8.17E-02 8.13E-02
Ps90%/90% (-KTL) Biased
6.77E-02 6.82E-02 6.81E-02 6.84E-02 6.88E-02 6.84E-02 6.86E-02
Un-Biased Statistics
Average Un-Biased
7.43E-02 7.44E-02 7.49E-02 7.51E-02 7.56E-02 7.52E-02 7.50E-02
Std Dev Un-Biased
8.47E-04 1.07E-03 9.26E-04 9.21E-04 1.01E-03 1.03E-03 8.78E-04
Ps90%/90% (+KTL) Un-Biased
7.67E-02 7.74E-02 7.75E-02 7.76E-02 7.83E-02 7.80E-02 7.74E-02
Ps90%/90% (-KTL) Un-Biased
7.20E-02 7.15E-02 7.24E-02 7.26E-02 7.28E-02 7.23E-02 7.26E-02
Specification MAX
1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
122
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High2 2 15V (V)
@ VS=+/-15V IL=1mA
1.60E-01
1.40E-01
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.56. Plot of Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
123
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.56. Raw data for Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High2 2 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=1mA
Device
0
10
20
30
50
60
70
557 6.71E-02 6.76E-02 6.79E-02 6.82E-02 6.84E-02 6.79E-02 6.80E-02
563 7.57E-02 7.62E-02 7.66E-02 7.68E-02 7.68E-02 7.68E-02 7.67E-02
564 7.51E-02 7.57E-02 7.64E-02 7.70E-02 7.68E-02 7.67E-02 7.64E-02
567 7.58E-02 7.67E-02 7.71E-02 7.71E-02 7.73E-02 7.73E-02 7.68E-02
569 7.26E-02 7.33E-02 7.38E-02 7.39E-02 7.39E-02 7.39E-02 7.34E-02
570 7.45E-02 7.46E-02 7.49E-02 7.51E-02 7.57E-02 7.54E-02 7.51E-02
571 7.31E-02 7.29E-02 7.33E-02 7.38E-02 7.45E-02 7.37E-02 7.35E-02
572 7.11E-02 7.09E-02 7.16E-02 7.18E-02 7.20E-02 7.18E-02 7.15E-02
573 7.55E-02 7.60E-02 7.63E-02 7.64E-02 7.69E-02 7.66E-02 7.60E-02
574 7.03E-02 7.03E-02 7.12E-02 7.11E-02 7.14E-02 7.11E-02 7.12E-02
584 7.44E-02 7.49E-02 7.49E-02 7.47E-02 7.43E-02 7.40E-02 7.40E-02
585 7.47E-02 7.46E-02 7.50E-02 7.49E-02 7.51E-02 7.40E-02 7.44E-02
Biased Statistics
Average Biased
7.33E-02 7.39E-02 7.44E-02 7.46E-02 7.46E-02 7.45E-02 7.43E-02
Std Dev Biased
3.68E-03 3.76E-03 3.86E-03 3.80E-03 3.73E-03 3.94E-03 3.75E-03
Ps90%/90% (+KTL) Biased
8.34E-02 8.42E-02 8.49E-02 8.50E-02 8.49E-02 8.53E-02 8.45E-02
Ps90%/90% (-KTL) Biased
6.32E-02 6.36E-02 6.38E-02 6.42E-02 6.44E-02 6.37E-02 6.40E-02
Un-Biased Statistics
Average Un-Biased
7.29E-02 7.29E-02 7.35E-02 7.36E-02 7.41E-02 7.37E-02 7.35E-02
Std Dev Un-Biased
2.20E-03 2.42E-03 2.16E-03 2.21E-03 2.35E-03 2.35E-03 2.12E-03
Ps90%/90% (+KTL) Un-Biased
7.89E-02 7.96E-02 7.94E-02 7.97E-02 8.05E-02 8.02E-02 7.93E-02
Ps90%/90% (-KTL) Un-Biased
6.69E-02 6.63E-02 6.75E-02 6.76E-02 6.77E-02 6.73E-02 6.76E-02
Specification MAX
1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
124
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High2 3 15V (V)
@ VS=+/-15V IL=1mA
1.60E-01
1.40E-01
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.57. Plot of Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
125
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.57. Raw data for Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High2 3 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=1mA
Device
0
10
20
30
50
60
70
557 6.76E-02 6.79E-02 6.81E-02 6.86E-02 6.85E-02 6.84E-02 6.83E-02
563 7.60E-02 7.67E-02 7.69E-02 7.71E-02 7.73E-02 7.73E-02 7.72E-02
564 7.49E-02 7.56E-02 7.62E-02 7.67E-02 7.64E-02 7.64E-02 7.62E-02
567 7.56E-02 7.64E-02 7.69E-02 7.72E-02 7.72E-02 7.70E-02 7.68E-02
569 7.25E-02 7.33E-02 7.36E-02 7.38E-02 7.40E-02 7.39E-02 7.35E-02
570 7.47E-02 7.48E-02 7.47E-02 7.56E-02 7.57E-02 7.56E-02 7.54E-02
571 7.27E-02 7.28E-02 7.32E-02 7.35E-02 7.43E-02 7.37E-02 7.36E-02
572 7.11E-02 7.11E-02 7.18E-02 7.19E-02 7.21E-02 7.18E-02 7.17E-02
573 7.58E-02 7.60E-02 7.65E-02 7.66E-02 7.71E-02 7.69E-02 7.62E-02
574 7.03E-02 7.01E-02 7.08E-02 7.11E-02 7.11E-02 7.13E-02 7.08E-02
584 7.48E-02 7.52E-02 7.47E-02 7.50E-02 7.46E-02 7.43E-02 7.43E-02
585 7.44E-02 7.45E-02 7.49E-02 7.48E-02 7.47E-02 7.39E-02 7.43E-02
Biased Statistics
Average Biased
7.33E-02 7.40E-02 7.43E-02 7.47E-02 7.47E-02 7.46E-02 7.44E-02
Std Dev Biased
3.46E-03 3.66E-03 3.74E-03 3.68E-03 3.69E-03 3.69E-03 3.68E-03
Ps90%/90% (+KTL) Biased
8.28E-02 8.40E-02 8.46E-02 8.48E-02 8.48E-02 8.47E-02 8.45E-02
Ps90%/90% (-KTL) Biased
6.38E-02 6.39E-02 6.41E-02 6.46E-02 6.45E-02 6.45E-02 6.43E-02
Un-Biased Statistics
Average Un-Biased
7.29E-02 7.30E-02 7.34E-02 7.38E-02 7.41E-02 7.39E-02 7.35E-02
Std Dev Un-Biased
2.30E-03 2.46E-03 2.28E-03 2.36E-03 2.48E-03 2.42E-03 2.34E-03
Ps90%/90% (+KTL) Un-Biased
7.92E-02 7.97E-02 7.96E-02 8.02E-02 8.08E-02 8.05E-02 8.00E-02
Ps90%/90% (-KTL) Un-Biased
6.66E-02 6.62E-02 6.71E-02 6.73E-02 6.73E-02 6.72E-02 6.71E-02
Specification MAX
1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
126
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High2 4 15V (V)
@ VS=+/-15V IL=1mA
1.60E-01
1.40E-01
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.58. Plot of Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
127
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.58. Raw data for Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High2 4 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=1mA
Device
0
10
20
30
50
60
70
557 7.02E-02 7.07E-02 7.09E-02 7.13E-02 7.14E-02 7.10E-02 7.10E-02
563 7.43E-02 7.49E-02 7.54E-02 7.55E-02 7.56E-02 7.56E-02 7.54E-02
564 7.55E-02 7.63E-02 7.67E-02 7.74E-02 7.72E-02 7.69E-02 7.70E-02
567 7.54E-02 7.62E-02 7.68E-02 7.68E-02 7.67E-02 7.67E-02 7.65E-02
569 7.39E-02 7.45E-02 7.50E-02 7.50E-02 7.52E-02 7.50E-02 7.47E-02
570 7.45E-02 7.47E-02 7.49E-02 7.52E-02 7.56E-02 7.53E-02 7.51E-02
571 7.42E-02 7.40E-02 7.47E-02 7.50E-02 7.56E-02 7.48E-02 7.47E-02
572 7.43E-02 7.42E-02 7.49E-02 7.51E-02 7.56E-02 7.51E-02 7.48E-02
573 7.54E-02 7.57E-02 7.62E-02 7.64E-02 7.69E-02 7.67E-02 7.59E-02
574 7.30E-02 7.27E-02 7.33E-02 7.35E-02 7.37E-02 7.37E-02 7.34E-02
584 7.11E-02 7.15E-02 7.15E-02 7.13E-02 7.11E-02 7.08E-02 7.09E-02
585 7.10E-02 7.08E-02 7.13E-02 7.09E-02 7.10E-02 7.03E-02 7.06E-02
Biased Statistics
Average Biased
7.39E-02 7.45E-02 7.50E-02 7.52E-02 7.52E-02 7.50E-02 7.49E-02
Std Dev Biased
2.17E-03 2.27E-03 2.43E-03 2.40E-03 2.30E-03 2.37E-03 2.36E-03
Ps90%/90% (+KTL) Biased
7.98E-02 8.07E-02 8.16E-02 8.17E-02 8.15E-02 8.15E-02 8.14E-02
Ps90%/90% (-KTL) Biased
6.79E-02 6.83E-02 6.83E-02 6.86E-02 6.89E-02 6.85E-02 6.84E-02
Un-Biased Statistics
Average Un-Biased
7.43E-02 7.43E-02 7.48E-02 7.50E-02 7.55E-02 7.51E-02 7.48E-02
Std Dev Un-Biased
8.40E-04 1.08E-03 1.05E-03 1.02E-03 1.16E-03 1.09E-03 8.94E-04
Ps90%/90% (+KTL) Un-Biased
7.66E-02 7.72E-02 7.77E-02 7.78E-02 7.87E-02 7.81E-02 7.72E-02
Ps90%/90% (-KTL) Un-Biased
7.20E-02 7.13E-02 7.19E-02 7.22E-02 7.23E-02 7.21E-02 7.23E-02
Specification MAX
1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
128
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High3 1 15V (V)
@ VS=+/-15V IL=10mA
9.00E-01
8.00E-01
7.00E-01
6.00E-01
5.00E-01
4.00E-01
3.00E-01
2.00E-01
1.00E-01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.59. Plot of Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
129
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.59. Raw data for Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High3 1 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=10mA
Device
0
10
20
30
50
60
70
557 3.56E-01 3.57E-01 3.58E-01 3.59E-01 3.59E-01 3.59E-01 3.58E-01
563 3.76E-01 3.78E-01 3.79E-01 3.80E-01 3.81E-01 3.80E-01 3.80E-01
564 3.81E-01 3.84E-01 3.86E-01 3.88E-01 3.88E-01 3.86E-01 3.86E-01
567 3.79E-01 3.83E-01 3.84E-01 3.86E-01 3.86E-01 3.85E-01 3.84E-01
569 3.73E-01 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01
570 3.75E-01 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01
571 3.74E-01 3.73E-01 3.75E-01 3.77E-01 3.79E-01 3.77E-01 3.76E-01
572 3.77E-01 3.77E-01 3.78E-01 3.80E-01 3.81E-01 3.79E-01 3.79E-01
573 3.79E-01 3.80E-01 3.81E-01 3.82E-01 3.84E-01 3.83E-01 3.81E-01
574 3.68E-01 3.68E-01 3.70E-01 3.71E-01 3.72E-01 3.71E-01 3.70E-01
584 3.60E-01 3.62E-01 3.61E-01 3.62E-01 3.60E-01 3.58E-01 3.60E-01
585 3.59E-01 3.59E-01 3.62E-01 3.60E-01 3.60E-01 3.58E-01 3.59E-01
Biased Statistics
Average Biased
3.73E-01 3.75E-01 3.77E-01 3.78E-01 3.78E-01 3.78E-01 3.77E-01
Std Dev Biased
1.01E-02 1.09E-02 1.12E-02 1.13E-02 1.13E-02 1.12E-02 1.11E-02
Ps90%/90% (+KTL) Biased
4.01E-01 4.05E-01 4.07E-01 4.09E-01 4.09E-01 4.08E-01 4.07E-01
Ps90%/90% (-KTL) Biased
3.45E-01 3.45E-01 3.46E-01 3.47E-01 3.47E-01 3.47E-01 3.46E-01
Un-Biased Statistics
Average Un-Biased
3.74E-01 3.75E-01 3.76E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01
Std Dev Un-Biased
3.91E-03 4.60E-03 4.07E-03 4.20E-03 4.29E-03 4.25E-03 4.01E-03
Ps90%/90% (+KTL) Un-Biased
3.85E-01 3.87E-01 3.87E-01 3.89E-01 3.91E-01 3.89E-01 3.88E-01
Ps90%/90% (-KTL) Un-Biased
3.64E-01 3.62E-01 3.65E-01 3.66E-01 3.67E-01 3.66E-01 3.66E-01
Specification MAX
8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
130
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High3 2 15V (V)
@ VS=+/-15V IL=10mA
9.00E-01
8.00E-01
7.00E-01
6.00E-01
5.00E-01
4.00E-01
3.00E-01
2.00E-01
1.00E-01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.60. Plot of Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
131
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.60. Raw data for Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High3 2 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=10mA
Device
0
10
20
30
50
60
70
557 3.46E-01 3.46E-01 3.47E-01 3.49E-01 3.48E-01 3.47E-01 3.47E-01
563 3.81E-01 3.82E-01 3.84E-01 3.85E-01 3.86E-01 3.86E-01 3.85E-01
564 3.81E-01 3.84E-01 3.85E-01 3.88E-01 3.88E-01 3.86E-01 3.85E-01
567 3.82E-01 3.85E-01 3.87E-01 3.88E-01 3.88E-01 3.88E-01 3.86E-01
569 3.69E-01 3.72E-01 3.72E-01 3.74E-01 3.74E-01 3.73E-01 3.72E-01
570 3.75E-01 3.76E-01 3.78E-01 3.79E-01 3.80E-01 3.79E-01 3.78E-01
571 3.68E-01 3.68E-01 3.70E-01 3.71E-01 3.73E-01 3.71E-01 3.70E-01
572 3.60E-01 3.59E-01 3.61E-01 3.62E-01 3.64E-01 3.62E-01 3.61E-01
573 3.80E-01 3.81E-01 3.82E-01 3.84E-01 3.85E-01 3.85E-01 3.82E-01
574 3.58E-01 3.58E-01 3.60E-01 3.61E-01 3.61E-01 3.60E-01 3.60E-01
584 3.76E-01 3.78E-01 3.78E-01 3.77E-01 3.76E-01 3.74E-01 3.75E-01
585 3.76E-01 3.76E-01 3.79E-01 3.77E-01 3.78E-01 3.74E-01 3.75E-01
Biased Statistics
Average Biased
3.72E-01 3.74E-01 3.75E-01 3.77E-01 3.77E-01 3.76E-01 3.75E-01
Std Dev Biased
1.55E-02 1.64E-02 1.69E-02 1.68E-02 1.70E-02 1.71E-02 1.66E-02
Ps90%/90% (+KTL) Biased
4.14E-01 4.19E-01 4.21E-01 4.22E-01 4.24E-01 4.23E-01 4.21E-01
Ps90%/90% (-KTL) Biased
3.29E-01 3.29E-01 3.29E-01 3.31E-01 3.30E-01 3.29E-01 3.30E-01
Un-Biased Statistics
Average Un-Biased
3.68E-01 3.68E-01 3.70E-01 3.71E-01 3.73E-01 3.71E-01 3.70E-01
Std Dev Un-Biased
9.34E-03 1.01E-02 9.90E-03 9.83E-03 1.02E-02 1.04E-02 9.92E-03
Ps90%/90% (+KTL) Un-Biased
3.94E-01 3.96E-01 3.97E-01 3.98E-01 4.01E-01 4.00E-01 3.97E-01
Ps90%/90% (-KTL) Un-Biased
3.43E-01 3.41E-01 3.43E-01 3.44E-01 3.45E-01 3.43E-01 3.43E-01
Specification MAX
8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
132
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High3 3 15V (V)
@ VS=+/-15V IL=10mA
9.00E-01
8.00E-01
7.00E-01
6.00E-01
5.00E-01
4.00E-01
3.00E-01
2.00E-01
1.00E-01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.61. Plot of Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
133
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.61. Raw data for Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High3 3 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=10mA
Device
0
10
20
30
50
60
70
557 3.46E-01 3.47E-01 3.48E-01 3.49E-01 3.49E-01 3.48E-01 3.48E-01
563 3.83E-01 3.86E-01 3.87E-01 3.88E-01 3.89E-01 3.88E-01 3.87E-01
564 3.79E-01 3.82E-01 3.84E-01 3.86E-01 3.86E-01 3.85E-01 3.85E-01
567 3.81E-01 3.84E-01 3.86E-01 3.87E-01 3.87E-01 3.87E-01 3.85E-01
569 3.68E-01 3.72E-01 3.73E-01 3.73E-01 3.74E-01 3.73E-01 3.72E-01
570 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.81E-01 3.80E-01 3.78E-01
571 3.67E-01 3.67E-01 3.69E-01 3.70E-01 3.73E-01 3.70E-01 3.69E-01
572 3.60E-01 3.60E-01 3.61E-01 3.63E-01 3.64E-01 3.62E-01 3.61E-01
573 3.80E-01 3.81E-01 3.83E-01 3.84E-01 3.86E-01 3.85E-01 3.83E-01
574 3.57E-01 3.57E-01 3.59E-01 3.59E-01 3.60E-01 3.60E-01 3.59E-01
584 3.77E-01 3.79E-01 3.78E-01 3.78E-01 3.77E-01 3.76E-01 3.76E-01
585 3.76E-01 3.76E-01 3.78E-01 3.76E-01 3.77E-01 3.74E-01 3.75E-01
Biased Statistics
Average Biased
3.71E-01 3.74E-01 3.75E-01 3.77E-01 3.77E-01 3.76E-01 3.75E-01
Std Dev Biased
1.53E-02 1.62E-02 1.63E-02 1.65E-02 1.67E-02 1.67E-02 1.65E-02
Ps90%/90% (+KTL) Biased
4.13E-01 4.18E-01 4.20E-01 4.22E-01 4.23E-01 4.22E-01 4.21E-01
Ps90%/90% (-KTL) Biased
3.30E-01 3.30E-01 3.31E-01 3.31E-01 3.31E-01 3.30E-01 3.30E-01
Un-Biased Statistics
Average Un-Biased
3.68E-01 3.68E-01 3.70E-01 3.71E-01 3.73E-01 3.71E-01 3.70E-01
Std Dev Un-Biased
1.00E-02 1.06E-02 1.05E-02 1.05E-02 1.09E-02 1.09E-02 1.06E-02
Ps90%/90% (+KTL) Un-Biased
3.95E-01 3.97E-01 3.99E-01 4.00E-01 4.02E-01 4.01E-01 3.99E-01
Ps90%/90% (-KTL) Un-Biased
3.40E-01 3.39E-01 3.41E-01 3.42E-01 3.43E-01 3.42E-01 3.41E-01
Specification MAX
8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
134
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing High3 4 15V (V)
@ VS=+/-15V IL=10mA
9.00E-01
8.00E-01
7.00E-01
6.00E-01
5.00E-01
4.00E-01
3.00E-01
2.00E-01
1.00E-01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.62. Plot of Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
135
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.62. Raw data for Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High3 4 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=10mA
Device
0
10
20
30
50
60
70
557 3.56E-01 3.57E-01 3.58E-01 3.59E-01 3.60E-01 3.59E-01 3.58E-01
563 3.76E-01 3.77E-01 3.79E-01 3.80E-01 3.81E-01 3.80E-01 3.79E-01
564 3.82E-01 3.85E-01 3.87E-01 3.89E-01 3.89E-01 3.87E-01 3.87E-01
567 3.79E-01 3.83E-01 3.84E-01 3.85E-01 3.86E-01 3.85E-01 3.84E-01
569 3.73E-01 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01
570 3.75E-01 3.75E-01 3.76E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01
571 3.74E-01 3.74E-01 3.76E-01 3.77E-01 3.80E-01 3.77E-01 3.76E-01
572 3.76E-01 3.76E-01 3.78E-01 3.79E-01 3.80E-01 3.79E-01 3.78E-01
573 3.79E-01 3.80E-01 3.82E-01 3.83E-01 3.85E-01 3.83E-01 3.82E-01
574 3.67E-01 3.67E-01 3.70E-01 3.70E-01 3.71E-01 3.70E-01 3.70E-01
584 3.60E-01 3.62E-01 3.61E-01 3.61E-01 3.60E-01 3.59E-01 3.60E-01
585 3.59E-01 3.59E-01 3.62E-01 3.60E-01 3.60E-01 3.57E-01 3.59E-01
Biased Statistics
Average Biased
3.73E-01 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.78E-01 3.77E-01
Std Dev Biased
1.01E-02 1.10E-02 1.15E-02 1.14E-02 1.14E-02 1.14E-02 1.12E-02
Ps90%/90% (+KTL) Biased
4.01E-01 4.06E-01 4.08E-01 4.09E-01 4.10E-01 4.09E-01 4.08E-01
Ps90%/90% (-KTL) Biased
3.46E-01 3.45E-01 3.46E-01 3.47E-01 3.48E-01 3.47E-01 3.46E-01
Un-Biased Statistics
Average Un-Biased
3.74E-01 3.75E-01 3.76E-01 3.77E-01 3.79E-01 3.78E-01 3.76E-01
Std Dev Un-Biased
4.34E-03 4.78E-03 4.33E-03 4.58E-03 4.74E-03 4.67E-03 4.33E-03
Ps90%/90% (+KTL) Un-Biased
3.86E-01 3.88E-01 3.88E-01 3.90E-01 3.92E-01 3.90E-01 3.88E-01
Ps90%/90% (-KTL) Un-Biased
3.62E-01 3.62E-01 3.64E-01 3.65E-01 3.66E-01 3.65E-01 3.65E-01
Specification MAX
8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
136
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low1 1 15V (V)
@ VS=+/-15V IL=0mA
7.00E-02
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.63. Plot of Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
137
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.63. Raw data for Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low1 1 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=0mA
60
70
Device
0
10
20
30
50
557 1.89E-02 1.90E-02 1.91E-02 1.92E-02 1.93E-02 1.92E-02 1.92E-02
563 1.79E-02 1.79E-02 1.80E-02 1.81E-02 1.83E-02 1.82E-02 1.81E-02
564 1.77E-02 1.78E-02 1.79E-02 1.81E-02 1.82E-02 1.80E-02 1.79E-02
567 1.75E-02 1.77E-02 1.79E-02 1.80E-02 1.80E-02 1.80E-02 1.78E-02
569 1.76E-02 1.78E-02 1.79E-02 1.79E-02 1.81E-02 1.80E-02 1.79E-02
570 1.77E-02 1.79E-02 1.80E-02 1.79E-02 1.80E-02 1.82E-02 1.79E-02
571 1.82E-02 1.80E-02 1.83E-02 1.83E-02 1.86E-02 1.84E-02 1.82E-02
572 1.83E-02 1.82E-02 1.85E-02 1.83E-02 1.85E-02 1.84E-02 1.85E-02
573 1.78E-02 1.82E-02 1.81E-02 1.82E-02 1.83E-02 1.83E-02 1.81E-02
574 1.82E-02 1.81E-02 1.84E-02 1.84E-02 1.86E-02 1.85E-02 1.83E-02
584 1.87E-02 1.88E-02 1.91E-02 1.89E-02 1.88E-02 1.89E-02 1.87E-02
585 1.86E-02 1.87E-02 1.90E-02 1.88E-02 1.87E-02 1.85E-02 1.85E-02
Biased Statistics
Average Biased
1.79E-02 1.80E-02 1.81E-02 1.83E-02 1.84E-02 1.83E-02 1.82E-02
Std Dev Biased
5.75E-04 5.20E-04 5.23E-04 5.17E-04 5.11E-04 5.40E-04 5.66E-04
Ps90%/90% (+KTL) Biased
1.95E-02 1.95E-02 1.96E-02 1.97E-02 1.98E-02 1.98E-02 1.97E-02
Ps90%/90% (-KTL) Biased
1.63E-02 1.66E-02 1.67E-02 1.68E-02 1.70E-02 1.68E-02 1.66E-02
Un-Biased Statistics
Average Un-Biased
1.80E-02 1.81E-02 1.83E-02 1.82E-02 1.84E-02 1.84E-02 1.82E-02
Std Dev Un-Biased
2.66E-04 1.43E-04 2.26E-04 1.84E-04 2.48E-04 1.11E-04 2.35E-04
Ps90%/90% (+KTL) Un-Biased
1.88E-02 1.85E-02 1.89E-02 1.87E-02 1.91E-02 1.87E-02 1.88E-02
Ps90%/90% (-KTL) Un-Biased
1.73E-02 1.77E-02 1.76E-02 1.77E-02 1.77E-02 1.80E-02 1.76E-02
Specification MAX
3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
138
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low1 2 15V (V)
@ VS=+/-15V IL=0mA
7.00E-02
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.64. Plot of Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
139
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.64. Raw data for Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low1 2 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=0mA
60
70
Device
0
10
20
30
50
557 1.91E-02 1.92E-02 1.94E-02 1.94E-02 1.95E-02 1.92E-02 1.91E-02
563 1.80E-02 1.83E-02 1.84E-02 1.84E-02 1.85E-02 1.85E-02 1.83E-02
564 1.79E-02 1.83E-02 1.87E-02 1.86E-02 1.87E-02 1.85E-02 1.85E-02
567 1.78E-02 1.82E-02 1.85E-02 1.84E-02 1.83E-02 1.84E-02 1.81E-02
569 1.87E-02 1.89E-02 1.90E-02 1.90E-02 1.92E-02 1.92E-02 1.89E-02
570 1.84E-02 1.83E-02 1.86E-02 1.85E-02 1.85E-02 1.86E-02 1.84E-02
571 1.83E-02 1.84E-02 1.87E-02 1.86E-02 1.87E-02 1.86E-02 1.85E-02
572 1.88E-02 1.88E-02 1.89E-02 1.89E-02 1.90E-02 1.91E-02 1.90E-02
573 1.91E-02 1.91E-02 1.94E-02 1.92E-02 1.93E-02 1.93E-02 1.90E-02
574 1.88E-02 1.88E-02 1.89E-02 1.91E-02 1.89E-02 1.91E-02 1.89E-02
584 1.83E-02 1.84E-02 1.85E-02 1.85E-02 1.83E-02 1.83E-02 1.82E-02
585 1.84E-02 1.83E-02 1.88E-02 1.87E-02 1.85E-02 1.82E-02 1.83E-02
Biased Statistics
Average Biased
1.83E-02 1.86E-02 1.88E-02 1.88E-02 1.88E-02 1.88E-02 1.86E-02
Std Dev Biased
5.54E-04 4.42E-04 4.05E-04 4.15E-04 5.03E-04 4.04E-04 4.29E-04
Ps90%/90% (+KTL) Biased
1.98E-02 1.98E-02 1.99E-02 1.99E-02 2.02E-02 1.99E-02 1.98E-02
Ps90%/90% (-KTL) Biased
1.68E-02 1.74E-02 1.77E-02 1.76E-02 1.74E-02 1.76E-02 1.74E-02
Un-Biased Statistics
Average Un-Biased
1.87E-02 1.87E-02 1.89E-02 1.89E-02 1.89E-02 1.89E-02 1.88E-02
Std Dev Un-Biased
3.25E-04 3.45E-04 3.09E-04 3.06E-04 3.20E-04 3.29E-04 2.98E-04
Ps90%/90% (+KTL) Un-Biased
1.96E-02 1.96E-02 1.97E-02 1.97E-02 1.98E-02 1.98E-02 1.96E-02
Ps90%/90% (-KTL) Un-Biased
1.78E-02 1.77E-02 1.80E-02 1.80E-02 1.80E-02 1.80E-02 1.79E-02
Specification MAX
3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
140
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low1 3 15V (V)
@ VS=+/-15V IL=0mA
7.00E-02
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.65. Plot of Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
141
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.65. Raw data for Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low1 3 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=0mA
60
70
Device
0
10
20
30
50
557 1.89E-02 1.89E-02 1.91E-02 1.93E-02 1.93E-02 1.93E-02 1.90E-02
563 1.77E-02 1.78E-02 1.80E-02 1.81E-02 1.81E-02 1.82E-02 1.78E-02
564 1.79E-02 1.79E-02 1.82E-02 1.84E-02 1.82E-02 1.82E-02 1.82E-02
567 1.74E-02 1.79E-02 1.78E-02 1.78E-02 1.81E-02 1.79E-02 1.78E-02
569 1.86E-02 1.88E-02 1.91E-02 1.90E-02 1.91E-02 1.90E-02 1.90E-02
570 1.76E-02 1.77E-02 1.78E-02 1.79E-02 1.79E-02 1.79E-02 1.78E-02
571 1.83E-02 1.83E-02 1.86E-02 1.85E-02 1.86E-02 1.85E-02 1.84E-02
572 1.82E-02 1.86E-02 1.86E-02 1.84E-02 1.86E-02 1.86E-02 1.84E-02
573 1.83E-02 1.83E-02 1.85E-02 1.87E-02 1.86E-02 1.86E-02 1.84E-02
574 1.86E-02 1.86E-02 1.88E-02 1.89E-02 1.89E-02 1.90E-02 1.87E-02
584 1.81E-02 1.81E-02 1.82E-02 1.81E-02 1.79E-02 1.79E-02 1.78E-02
585 1.81E-02 1.82E-02 1.87E-02 1.83E-02 1.83E-02 1.80E-02 1.81E-02
Biased Statistics
Average Biased
1.81E-02 1.83E-02 1.84E-02 1.85E-02 1.86E-02 1.85E-02 1.84E-02
Std Dev Biased
6.13E-04 5.54E-04 6.04E-04 6.17E-04 6.06E-04 5.94E-04 6.09E-04
Ps90%/90% (+KTL) Biased
1.98E-02 1.98E-02 2.01E-02 2.02E-02 2.02E-02 2.02E-02 2.00E-02
Ps90%/90% (-KTL) Biased
1.64E-02 1.67E-02 1.68E-02 1.68E-02 1.69E-02 1.69E-02 1.67E-02
Un-Biased Statistics
Average Un-Biased
1.82E-02 1.83E-02 1.85E-02 1.85E-02 1.85E-02 1.85E-02 1.83E-02
Std Dev Un-Biased
3.62E-04 3.78E-04 4.03E-04 3.88E-04 3.85E-04 4.03E-04 3.47E-04
Ps90%/90% (+KTL) Un-Biased
1.92E-02 1.93E-02 1.96E-02 1.95E-02 1.96E-02 1.96E-02 1.93E-02
Ps90%/90% (-KTL) Un-Biased
1.72E-02 1.72E-02 1.74E-02 1.74E-02 1.74E-02 1.74E-02 1.74E-02
Specification MAX
3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
142
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low1 4 15V (V)
@ VS=+/-15V IL=0mA
7.00E-02
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.66. Plot of Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
143
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.66. Raw data for Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low1 4 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=0mA
60
70
Device
0
10
20
30
50
557 1.90E-02 1.91E-02 1.95E-02 1.92E-02 1.94E-02 1.93E-02 1.92E-02
563 1.81E-02 1.82E-02 1.83E-02 1.85E-02 1.85E-02 1.85E-02 1.83E-02
564 1.81E-02 1.83E-02 1.84E-02 1.87E-02 1.85E-02 1.85E-02 1.82E-02
567 1.78E-02 1.81E-02 1.82E-02 1.81E-02 1.83E-02 1.83E-02 1.81E-02
569 1.80E-02 1.83E-02 1.84E-02 1.83E-02 1.83E-02 1.81E-02 1.83E-02
570 1.84E-02 1.84E-02 1.84E-02 1.85E-02 1.85E-02 1.85E-02 1.84E-02
571 1.85E-02 1.86E-02 1.88E-02 1.87E-02 1.88E-02 1.87E-02 1.85E-02
572 1.84E-02 1.84E-02 1.84E-02 1.84E-02 1.88E-02 1.86E-02 1.85E-02
573 1.84E-02 1.85E-02 1.86E-02 1.87E-02 1.87E-02 1.87E-02 1.86E-02
574 1.82E-02 1.83E-02 1.84E-02 1.85E-02 1.85E-02 1.85E-02 1.83E-02
584 1.88E-02 1.89E-02 1.90E-02 1.90E-02 1.88E-02 1.88E-02 1.89E-02
585 1.89E-02 1.89E-02 1.93E-02 1.89E-02 1.88E-02 1.88E-02 1.87E-02
Biased Statistics
Average Biased
1.82E-02 1.84E-02 1.85E-02 1.86E-02 1.86E-02 1.85E-02 1.84E-02
Std Dev Biased
4.83E-04 4.23E-04 5.15E-04 3.95E-04 4.54E-04 4.69E-04 4.65E-04
Ps90%/90% (+KTL) Biased
1.95E-02 1.96E-02 2.00E-02 1.97E-02 1.99E-02 1.98E-02 1.97E-02
Ps90%/90% (-KTL) Biased
1.69E-02 1.72E-02 1.71E-02 1.75E-02 1.74E-02 1.73E-02 1.71E-02
Un-Biased Statistics
Average Un-Biased
1.84E-02 1.84E-02 1.85E-02 1.86E-02 1.87E-02 1.86E-02 1.85E-02
Std Dev Un-Biased
1.28E-04 1.18E-04 1.79E-04 1.36E-04 1.35E-04 9.82E-05 1.16E-04
Ps90%/90% (+KTL) Un-Biased
1.87E-02 1.87E-02 1.90E-02 1.89E-02 1.90E-02 1.89E-02 1.88E-02
Ps90%/90% (-KTL) Un-Biased
1.80E-02 1.81E-02 1.80E-02 1.82E-02 1.83E-02 1.83E-02 1.81E-02
Specification MAX
3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
144
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low2 1 15V (V)
@ VS=+/-15V IL=1mA
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.67. Plot of Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
145
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.67. Raw data for Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low2 1 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=1mA
60
70
Device
0
10
20
30
50
557 5.24E-02 5.24E-02 5.26E-02 5.26E-02 5.26E-02 5.25E-02 5.26E-02
563 5.19E-02 5.19E-02 5.22E-02 5.23E-02 5.23E-02 5.20E-02 5.19E-02
564 5.18E-02 5.20E-02 5.22E-02 5.24E-02 5.23E-02 5.20E-02 5.22E-02
567 5.16E-02 5.20E-02 5.22E-02 5.22E-02 5.22E-02 5.20E-02 5.17E-02
569 5.17E-02 5.19E-02 5.19E-02 5.20E-02 5.21E-02 5.18E-02 5.18E-02
570 5.18E-02 5.20E-02 5.19E-02 5.21E-02 5.18E-02 5.19E-02 5.17E-02
571 5.23E-02 5.23E-02 5.26E-02 5.26E-02 5.26E-02 5.25E-02 5.22E-02
572 5.25E-02 5.24E-02 5.26E-02 5.25E-02 5.26E-02 5.25E-02 5.25E-02
573 5.23E-02 5.24E-02 5.24E-02 5.27E-02 5.25E-02 5.24E-02 5.22E-02
574 5.22E-02 5.21E-02 5.24E-02 5.22E-02 5.25E-02 5.22E-02 5.21E-02
584 5.25E-02 5.27E-02 5.29E-02 5.26E-02 5.24E-02 5.22E-02 5.22E-02
585 5.22E-02 5.25E-02 5.29E-02 5.25E-02 5.23E-02 5.21E-02 5.22E-02
Biased Statistics
Average Biased
5.19E-02 5.20E-02 5.22E-02 5.23E-02 5.23E-02 5.21E-02 5.20E-02
Std Dev Biased
3.27E-04 1.93E-04 2.31E-04 2.35E-04 1.97E-04 2.47E-04 3.60E-04
Ps90%/90% (+KTL) Biased
5.28E-02 5.26E-02 5.29E-02 5.30E-02 5.28E-02 5.27E-02 5.30E-02
Ps90%/90% (-KTL) Biased
5.10E-02 5.15E-02 5.16E-02 5.17E-02 5.17E-02 5.14E-02 5.11E-02
Un-Biased Statistics
Average Un-Biased
5.22E-02 5.22E-02 5.24E-02 5.24E-02 5.24E-02 5.23E-02 5.21E-02
Std Dev Un-Biased
2.82E-04 1.95E-04 2.92E-04 2.59E-04 3.51E-04 2.58E-04 2.65E-04
Ps90%/90% (+KTL) Un-Biased
5.30E-02 5.28E-02 5.32E-02 5.32E-02 5.33E-02 5.30E-02 5.29E-02
Ps90%/90% (-KTL) Un-Biased
5.14E-02 5.17E-02 5.16E-02 5.17E-02 5.14E-02 5.16E-02 5.14E-02
Specification MAX
1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
146
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low2 2 15V (V)
@ VS=+/-15V IL=1mA
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.68. Plot of Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
147
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.68. Raw data for Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low2 2 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=1mA
60
70
Device
0
10
20
30
50
557 5.23E-02 5.24E-02 5.23E-02 5.25E-02 5.25E-02 5.23E-02 5.25E-02
563 5.25E-02 5.25E-02 5.28E-02 5.30E-02 5.29E-02 5.25E-02 5.28E-02
564 5.27E-02 5.30E-02 5.31E-02 5.35E-02 5.32E-02 5.27E-02 5.30E-02
567 5.27E-02 5.29E-02 5.30E-02 5.30E-02 5.31E-02 5.29E-02 5.28E-02
569 5.28E-02 5.32E-02 5.33E-02 5.31E-02 5.31E-02 5.30E-02 5.31E-02
570 5.27E-02 5.31E-02 5.30E-02 5.29E-02 5.29E-02 5.31E-02 5.27E-02
571 5.26E-02 5.27E-02 5.30E-02 5.29E-02 5.28E-02 5.26E-02 5.24E-02
572 5.27E-02 5.26E-02 5.30E-02 5.27E-02 5.28E-02 5.25E-02 5.26E-02
573 5.39E-02 5.39E-02 5.41E-02 5.41E-02 5.40E-02 5.38E-02 5.37E-02
574 5.22E-02 5.23E-02 5.25E-02 5.26E-02 5.25E-02 5.22E-02 5.24E-02
584 5.26E-02 5.28E-02 5.27E-02 5.28E-02 5.25E-02 5.24E-02 5.24E-02
585 5.26E-02 5.28E-02 5.32E-02 5.30E-02 5.30E-02 5.26E-02 5.25E-02
Biased Statistics
Average Biased
5.26E-02 5.28E-02 5.29E-02 5.30E-02 5.29E-02 5.27E-02 5.28E-02
Std Dev Biased
2.26E-04 3.30E-04 3.57E-04 3.51E-04 2.61E-04 2.91E-04 2.55E-04
Ps90%/90% (+KTL) Biased
5.32E-02 5.37E-02 5.39E-02 5.40E-02 5.37E-02 5.35E-02 5.35E-02
Ps90%/90% (-KTL) Biased
5.20E-02 5.19E-02 5.19E-02 5.20E-02 5.22E-02 5.19E-02 5.21E-02
Un-Biased Statistics
Average Un-Biased
5.28E-02 5.29E-02 5.31E-02 5.30E-02 5.30E-02 5.28E-02 5.27E-02
Std Dev Un-Biased
6.33E-04 6.28E-04 5.71E-04 6.09E-04 5.76E-04 6.09E-04 5.30E-04
Ps90%/90% (+KTL) Un-Biased
5.45E-02 5.46E-02 5.47E-02 5.47E-02 5.46E-02 5.45E-02 5.42E-02
Ps90%/90% (-KTL) Un-Biased
5.11E-02 5.12E-02 5.15E-02 5.14E-02 5.14E-02 5.12E-02 5.13E-02
Specification MAX
1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
148
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low2 3 15V (V)
@ VS=+/-15V IL=1mA
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.69. Plot of Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
149
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.69. Raw data for Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low2 3 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=1mA
60
70
Device
0
10
20
30
50
557 5.18E-02 5.20E-02 5.21E-02 5.21E-02 5.22E-02 5.20E-02 5.19E-02
563 5.20E-02 5.20E-02 5.23E-02 5.25E-02 5.23E-02 5.23E-02 5.22E-02
564 5.21E-02 5.22E-02 5.24E-02 5.27E-02 5.25E-02 5.24E-02 5.23E-02
567 5.17E-02 5.22E-02 5.24E-02 5.25E-02 5.23E-02 5.23E-02 5.22E-02
569 5.27E-02 5.30E-02 5.31E-02 5.31E-02 5.29E-02 5.30E-02 5.30E-02
570 5.18E-02 5.18E-02 5.20E-02 5.19E-02 5.20E-02 5.20E-02 5.17E-02
571 5.23E-02 5.23E-02 5.25E-02 5.27E-02 5.26E-02 5.25E-02 5.24E-02
572 5.20E-02 5.22E-02 5.22E-02 5.23E-02 5.23E-02 5.21E-02 5.23E-02
573 5.27E-02 5.28E-02 5.31E-02 5.30E-02 5.30E-02 5.29E-02 5.27E-02
574 5.20E-02 5.21E-02 5.24E-02 5.23E-02 5.22E-02 5.22E-02 5.21E-02
584 5.19E-02 5.20E-02 5.22E-02 5.22E-02 5.19E-02 5.16E-02 5.17E-02
585 5.22E-02 5.22E-02 5.30E-02 5.26E-02 5.24E-02 5.20E-02 5.22E-02
Biased Statistics
Average Biased
5.21E-02 5.23E-02 5.25E-02 5.26E-02 5.24E-02 5.24E-02 5.23E-02
Std Dev Biased
4.08E-04 4.24E-04 3.55E-04 3.42E-04 2.78E-04 3.66E-04 3.87E-04
Ps90%/90% (+KTL) Biased
5.32E-02 5.34E-02 5.34E-02 5.35E-02 5.32E-02 5.34E-02 5.34E-02
Ps90%/90% (-KTL) Biased
5.09E-02 5.11E-02 5.15E-02 5.16E-02 5.17E-02 5.14E-02 5.12E-02
Un-Biased Statistics
Average Un-Biased
5.22E-02 5.22E-02 5.24E-02 5.25E-02 5.24E-02 5.23E-02 5.22E-02
Std Dev Un-Biased
3.48E-04 3.60E-04 3.94E-04 4.24E-04 4.01E-04 3.64E-04 3.58E-04
Ps90%/90% (+KTL) Un-Biased
5.31E-02 5.32E-02 5.35E-02 5.36E-02 5.35E-02 5.33E-02 5.32E-02
Ps90%/90% (-KTL) Un-Biased
5.12E-02 5.12E-02 5.14E-02 5.13E-02 5.13E-02 5.13E-02 5.12E-02
Specification MAX
1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
150
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low2 4 15V (V)
@ VS=+/-15V IL=1mA
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.70. Plot of Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
151
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.70. Raw data for Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low2 4 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=1mA
60
70
Device
0
10
20
30
50
557 5.26E-02 5.26E-02 5.27E-02 5.30E-02 5.29E-02 5.27E-02 5.26E-02
563 5.24E-02 5.24E-02 5.26E-02 5.29E-02 5.27E-02 5.26E-02 5.27E-02
564 5.24E-02 5.27E-02 5.30E-02 5.30E-02 5.28E-02 5.26E-02 5.27E-02
567 5.23E-02 5.25E-02 5.27E-02 5.27E-02 5.27E-02 5.26E-02 5.23E-02
569 5.21E-02 5.25E-02 5.25E-02 5.25E-02 5.24E-02 5.23E-02 5.24E-02
570 5.28E-02 5.28E-02 5.30E-02 5.28E-02 5.27E-02 5.28E-02 5.26E-02
571 5.30E-02 5.28E-02 5.33E-02 5.32E-02 5.31E-02 5.31E-02 5.30E-02
572 5.29E-02 5.28E-02 5.31E-02 5.32E-02 5.31E-02 5.28E-02 5.29E-02
573 5.32E-02 5.31E-02 5.34E-02 5.33E-02 5.32E-02 5.33E-02 5.31E-02
574 5.25E-02 5.25E-02 5.27E-02 5.27E-02 5.26E-02 5.25E-02 5.25E-02
584 5.28E-02 5.29E-02 5.30E-02 5.29E-02 5.27E-02 5.25E-02 5.26E-02
585 5.28E-02 5.29E-02 5.34E-02 5.30E-02 5.30E-02 5.25E-02 5.27E-02
Biased Statistics
Average Biased
5.23E-02 5.25E-02 5.27E-02 5.28E-02 5.27E-02 5.26E-02 5.25E-02
Std Dev Biased
1.66E-04 9.43E-05 1.89E-04 2.18E-04 1.78E-04 1.44E-04 1.88E-04
Ps90%/90% (+KTL) Biased
5.28E-02 5.28E-02 5.32E-02 5.34E-02 5.32E-02 5.30E-02 5.30E-02
Ps90%/90% (-KTL) Biased
5.19E-02 5.23E-02 5.22E-02 5.22E-02 5.22E-02 5.22E-02 5.20E-02
Un-Biased Statistics
Average Un-Biased
5.29E-02 5.28E-02 5.31E-02 5.30E-02 5.29E-02 5.29E-02 5.28E-02
Std Dev Un-Biased
2.54E-04 2.18E-04 2.70E-04 2.75E-04 2.60E-04 2.94E-04 2.50E-04
Ps90%/90% (+KTL) Un-Biased
5.36E-02 5.34E-02 5.38E-02 5.38E-02 5.36E-02 5.37E-02 5.35E-02
Ps90%/90% (-KTL) Un-Biased
5.22E-02 5.22E-02 5.23E-02 5.23E-02 5.22E-02 5.21E-02 5.21E-02
Specification MAX
1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
152
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low3 1 15V (V)
@ VS=+/-15V IL=10mA
6.00E-01
5.00E-01
4.00E-01
3.00E-01
2.00E-01
1.00E-01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.71. Plot of Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
153
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.71. Raw data for Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low3 1 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=10mA
60
70
Device
0
10
20
30
50
557 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.16E-01 2.16E-01
563 2.19E-01 2.18E-01 2.19E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01
564 2.20E-01 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.20E-01 2.21E-01
567 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01 2.20E-01
569 2.18E-01 2.19E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01 2.18E-01
570 2.18E-01 2.18E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01 2.17E-01
571 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.19E-01 2.19E-01
572 2.22E-01 2.21E-01 2.22E-01 2.22E-01 2.21E-01 2.21E-01 2.21E-01
573 2.20E-01 2.20E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01 2.20E-01
574 2.18E-01 2.18E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01 2.18E-01
584 2.17E-01 2.18E-01 2.18E-01 2.18E-01 2.17E-01 2.16E-01 2.17E-01
585 2.18E-01 2.19E-01 2.20E-01 2.19E-01 2.19E-01 2.17E-01 2.18E-01
Biased Statistics
Average Biased
2.19E-01 2.19E-01 2.19E-01 2.20E-01 2.19E-01 2.18E-01 2.19E-01
Std Dev Biased
1.47E-03 1.78E-03 1.64E-03 1.82E-03 1.68E-03 1.60E-03 1.66E-03
Ps90%/90% (+KTL) Biased
2.23E-01 2.24E-01 2.24E-01 2.25E-01 2.24E-01 2.23E-01 2.23E-01
Ps90%/90% (-KTL) Biased
2.15E-01 2.14E-01 2.15E-01 2.15E-01 2.14E-01 2.14E-01 2.14E-01
Un-Biased Statistics
Average Un-Biased
2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.19E-01 2.19E-01 2.19E-01
Std Dev Un-Biased
1.45E-03 1.36E-03 1.20E-03 1.35E-03 1.34E-03 1.26E-03 1.43E-03
Ps90%/90% (+KTL) Un-Biased
2.24E-01 2.23E-01 2.23E-01 2.24E-01 2.23E-01 2.22E-01 2.23E-01
Ps90%/90% (-KTL) Un-Biased
2.16E-01 2.16E-01 2.17E-01 2.16E-01 2.16E-01 2.15E-01 2.15E-01
Specification MAX
5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
154
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low3 2 15V (V)
@ VS=+/-15V IL=10mA
6.00E-01
5.00E-01
4.00E-01
3.00E-01
2.00E-01
1.00E-01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.72. Plot of Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
155
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.72. Raw data for Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low3 2 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=10mA
60
70
Device
0
10
20
30
50
557 2.16E-01 2.16E-01 2.17E-01 2.17E-01 2.17E-01 2.16E-01 2.16E-01
563 2.24E-01 2.23E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01 2.24E-01
564 2.23E-01 2.24E-01 2.24E-01 2.25E-01 2.24E-01 2.23E-01 2.24E-01
567 2.22E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01 2.23E-01 2.23E-01
569 2.22E-01 2.23E-01 2.23E-01 2.23E-01 2.22E-01 2.21E-01 2.22E-01
570 2.23E-01 2.23E-01 2.23E-01 2.23E-01 2.22E-01 2.22E-01 2.22E-01
571 2.21E-01 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01
572 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.19E-01 2.19E-01 2.19E-01
573 2.24E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01 2.23E-01 2.23E-01
574 2.19E-01 2.18E-01 2.19E-01 2.20E-01 2.19E-01 2.18E-01 2.18E-01
584 2.23E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01 2.22E-01 2.23E-01
585 2.23E-01 2.23E-01 2.25E-01 2.24E-01 2.24E-01 2.22E-01 2.22E-01
Biased Statistics
Average Biased
2.22E-01 2.22E-01 2.22E-01 2.23E-01 2.22E-01 2.21E-01 2.22E-01
Std Dev Biased
2.92E-03 3.30E-03 3.08E-03 3.21E-03 3.13E-03 2.96E-03 3.23E-03
Ps90%/90% (+KTL) Biased
2.30E-01 2.31E-01 2.31E-01 2.31E-01 2.31E-01 2.29E-01 2.31E-01
Ps90%/90% (-KTL) Biased
2.14E-01 2.13E-01 2.14E-01 2.14E-01 2.13E-01 2.13E-01 2.13E-01
Un-Biased Statistics
Average Un-Biased
2.21E-01 2.21E-01 2.22E-01 2.22E-01 2.21E-01 2.20E-01 2.20E-01
Std Dev Un-Biased
2.03E-03 2.25E-03 2.01E-03 1.95E-03 2.00E-03 2.09E-03 2.03E-03
Ps90%/90% (+KTL) Un-Biased
2.27E-01 2.27E-01 2.27E-01 2.27E-01 2.26E-01 2.26E-01 2.26E-01
Ps90%/90% (-KTL) Un-Biased
2.16E-01 2.15E-01 2.16E-01 2.16E-01 2.15E-01 2.15E-01 2.15E-01
Specification MAX
5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
156
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low3 3 15V (V)
@ VS=+/-15V IL=10mA
6.00E-01
5.00E-01
4.00E-01
3.00E-01
2.00E-01
1.00E-01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.73. Plot of Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
157
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.73. Raw data for Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low3 3 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=10mA
60
70
Device
0
10
20
30
50
557 2.14E-01 2.15E-01 2.15E-01 2.15E-01 2.15E-01 2.14E-01 2.14E-01
563 2.21E-01 2.22E-01 2.21E-01 2.22E-01 2.21E-01 2.20E-01 2.21E-01
564 2.21E-01 2.22E-01 2.22E-01 2.22E-01 2.22E-01 2.21E-01 2.22E-01
567 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01
569 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01 2.20E-01
570 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.19E-01 2.19E-01 2.19E-01
571 2.19E-01 2.19E-01 2.19E-01 2.20E-01 2.20E-01 2.18E-01 2.18E-01
572 2.18E-01 2.17E-01 2.18E-01 2.18E-01 2.17E-01 2.16E-01 2.17E-01
573 2.20E-01 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.21E-01 2.20E-01
574 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.16E-01 2.16E-01
584 2.20E-01 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.19E-01 2.19E-01
585 2.20E-01 2.20E-01 2.22E-01 2.21E-01 2.21E-01 2.20E-01 2.20E-01
Biased Statistics
Average Biased
2.19E-01 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.19E-01 2.19E-01
Std Dev Biased
2.88E-03 3.00E-03 3.02E-03 3.19E-03 2.92E-03 2.96E-03 3.16E-03
Ps90%/90% (+KTL) Biased
2.27E-01 2.28E-01 2.28E-01 2.29E-01 2.28E-01 2.27E-01 2.28E-01
Ps90%/90% (-KTL) Biased
2.11E-01 2.12E-01 2.12E-01 2.11E-01 2.12E-01 2.11E-01 2.11E-01
Un-Biased Statistics
Average Un-Biased
2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01
Std Dev Un-Biased
1.52E-03 1.67E-03 1.59E-03 1.74E-03 1.65E-03 1.82E-03 1.53E-03
Ps90%/90% (+KTL) Un-Biased
2.23E-01 2.23E-01 2.24E-01 2.24E-01 2.23E-01 2.23E-01 2.22E-01
Ps90%/90% (-KTL) Un-Biased
2.14E-01 2.14E-01 2.15E-01 2.14E-01 2.14E-01 2.13E-01 2.14E-01
Specification MAX
5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
158
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Output Voltage Swing Low3 4 15V (V)
@ VS=+/-15V IL=10mA
6.00E-01
5.00E-01
4.00E-01
3.00E-01
2.00E-01
1.00E-01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.74. Plot of Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
159
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.74. Raw data for Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low3 4 15V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+/-15V IL=10mA
60
70
Device
0
10
20
30
50
557 2.19E-01 2.18E-01 2.19E-01 2.19E-01 2.18E-01 2.18E-01 2.18E-01
563 2.21E-01 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.21E-01 2.21E-01
564 2.22E-01 2.23E-01 2.24E-01 2.24E-01 2.23E-01 2.22E-01 2.23E-01
567 2.22E-01 2.24E-01 2.23E-01 2.24E-01 2.23E-01 2.22E-01 2.23E-01
569 2.21E-01 2.22E-01 2.22E-01 2.22E-01 2.21E-01 2.21E-01 2.21E-01
570 2.22E-01 2.22E-01 2.22E-01 2.22E-01 2.21E-01 2.21E-01 2.21E-01
571 2.22E-01 2.22E-01 2.23E-01 2.23E-01 2.22E-01 2.21E-01 2.22E-01
572 2.24E-01 2.24E-01 2.25E-01 2.24E-01 2.24E-01 2.23E-01 2.24E-01
573 2.23E-01 2.24E-01 2.24E-01 2.24E-01 2.23E-01 2.22E-01 2.22E-01
574 2.21E-01 2.21E-01 2.22E-01 2.21E-01 2.21E-01 2.20E-01 2.21E-01
584 2.19E-01 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.18E-01 2.19E-01
585 2.21E-01 2.21E-01 2.23E-01 2.22E-01 2.21E-01 2.20E-01 2.21E-01
Biased Statistics
Average Biased
2.21E-01 2.22E-01 2.22E-01 2.22E-01 2.21E-01 2.21E-01 2.21E-01
Std Dev Biased
1.58E-03 2.07E-03 1.95E-03 2.03E-03 2.14E-03 1.67E-03 1.98E-03
Ps90%/90% (+KTL) Biased
2.25E-01 2.27E-01 2.27E-01 2.28E-01 2.27E-01 2.25E-01 2.27E-01
Ps90%/90% (-KTL) Biased
2.17E-01 2.16E-01 2.16E-01 2.17E-01 2.16E-01 2.16E-01 2.16E-01
Un-Biased Statistics
Average Un-Biased
2.23E-01 2.23E-01 2.23E-01 2.23E-01 2.22E-01 2.22E-01 2.22E-01
Std Dev Un-Biased
1.26E-03 1.34E-03 1.20E-03 1.30E-03 1.29E-03 1.04E-03 1.17E-03
Ps90%/90% (+KTL) Un-Biased
2.26E-01 2.26E-01 2.26E-01 2.26E-01 2.26E-01 2.24E-01 2.25E-01
Ps90%/90% (-KTL) Un-Biased
2.19E-01 2.19E-01 2.20E-01 2.19E-01 2.19E-01 2.19E-01 2.19E-01
Specification MAX
5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
160
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Large Signal Voltage Gain1 1 15V (V/mV)
@ VO=+/-14.5V, RL=10kΩ
1.50E+04
1.00E+04
5.00E+03
0.00E+00
-5.00E+03
-1.00E+04
-1.50E+04
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.75. Plot of Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
161
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.75. Raw data for Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain1 1 15V (V/mV)
@ VO=+/-14.5V, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Total Dose (krad(Si))
20
30
9.89E+03 9.65E+03
6.69E+03 6.25E+03
6.56E+03 6.24E+03
6.79E+03 6.07E+03
1.81E+04 1.39E+04
6.31E+03 5.93E+03
1.14E+04 9.22E+03
6.15E+03 7.49E+03
2.40E+04 2.30E+04
1.56E+04 1.33E+04
3.34E+04 2.94E+04
5.80E+03 5.69E+03
50
8.97E+03
7.06E+03
6.21E+03
6.14E+03
1.78E+04
6.41E+03
9.67E+03
7.14E+03
1.89E+04
1.33E+04
5.68E+04
6.68E+03
24 Hr
Anneal
60
9.92E+03
7.83E+03
6.98E+03
6.59E+03
2.22E+04
6.36E+03
1.04E+04
6.55E+03
2.45E+04
1.78E+04
5.24E+04
6.60E+03
168 Hr
Anneal
70
9.10E+03
7.06E+03
6.78E+03
6.55E+03
1.83E+04
6.62E+03
1.15E+04
5.88E+03
2.13E+04
1.52E+04
3.33E+04
5.94E+03
0
9.12E+03
6.54E+03
6.24E+03
6.32E+03
1.56E+04
6.24E+03
1.00E+04
6.19E+03
2.04E+04
1.41E+04
2.53E+04
5.76E+03
10
1.06E+04
6.82E+03
6.63E+03
6.43E+03
1.51E+04
6.06E+03
1.15E+04
5.81E+03
2.69E+04
1.71E+04
3.30E+04
5.98E+03
8.75E+03
3.99E+03
1.97E+04
-2.18E+03
9.11E+03
3.76E+03
1.94E+04
-1.19E+03
9.60E+03
4.93E+03
2.31E+04
-3.92E+03
8.42E+03
3.41E+03
1.78E+04
-9.37E+02
9.24E+03
4.94E+03
2.28E+04
-4.30E+03
1.07E+04
6.55E+03
2.87E+04
-7.26E+03
9.55E+03
4.98E+03
2.32E+04
-4.10E+03
1.14E+04
6.01E+03
2.79E+04
-5.08E+03
1.00E+03
PASS
1.35E+04
8.84E+03
3.77E+04
-1.07E+04
5.00E+02
PASS
1.27E+04
7.42E+03
3.30E+04
-7.67E+03
5.00E+02
PASS
1.18E+04
6.83E+03
3.05E+04
-6.95E+03
5.00E+02
PASS
1.11E+04
5.15E+03
2.52E+04
-3.02E+03
5.00E+02
PASS
1.31E+04
7.85E+03
3.46E+04
-8.40E+03
5.00E+02
PASS
1.21E+04
6.39E+03
2.96E+04
-5.40E+03
5.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
162
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Large Signal Voltage Gain1 2 15V (V/mV)
@ VO=+/-14.5V, RL=10kΩ
7.00E+03
6.00E+03
5.00E+03
4.00E+03
3.00E+03
2.00E+03
1.00E+03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.76. Plot of Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
163
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.76. Raw data for Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain1 2 15V (V/mV)
@ VO=+/-14.5V, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
3.82E+03
5.75E+03
5.77E+03
5.53E+03
3.55E+03
6.10E+03
6.36E+03
4.54E+03
6.17E+03
6.39E+03
3.70E+03
3.68E+03
24 Hr
Anneal
60
3.48E+03
5.84E+03
6.08E+03
5.58E+03
3.61E+03
6.06E+03
5.92E+03
4.33E+03
6.19E+03
6.45E+03
3.34E+03
3.65E+03
168 Hr
Anneal
70
3.59E+03
5.82E+03
5.97E+03
6.03E+03
3.60E+03
5.93E+03
6.21E+03
4.36E+03
6.08E+03
6.56E+03
3.67E+03
3.64E+03
0
3.74E+03
6.62E+03
5.82E+03
6.52E+03
3.82E+03
6.54E+03
6.62E+03
4.74E+03
6.88E+03
6.80E+03
5.55E+03
3.74E+03
10
3.70E+03
5.95E+03
6.18E+03
6.73E+03
3.65E+03
6.49E+03
6.90E+03
4.48E+03
6.51E+03
6.91E+03
3.70E+03
3.67E+03
Total Dose (krad(Si))
20
30
3.67E+03 3.68E+03
6.01E+03 5.87E+03
6.19E+03 5.92E+03
5.99E+03 5.88E+03
3.75E+03 3.74E+03
6.46E+03 6.29E+03
6.24E+03 6.33E+03
4.64E+03 4.43E+03
6.37E+03 6.44E+03
6.58E+03 6.76E+03
3.71E+03 3.71E+03
3.66E+03 3.65E+03
5.30E+03
1.42E+03
9.21E+03
1.40E+03
5.24E+03
1.46E+03
9.23E+03
1.25E+03
5.12E+03
1.29E+03
8.66E+03
1.58E+03
5.02E+03
1.20E+03
8.30E+03
1.74E+03
4.88E+03
1.10E+03
7.91E+03
1.86E+03
4.92E+03
1.27E+03
8.39E+03
1.44E+03
5.00E+03
1.29E+03
8.53E+03
1.47E+03
6.31E+03
8.90E+02
8.75E+03
3.87E+03
1.00E+03
PASS
6.26E+03
1.02E+03
9.05E+03
3.47E+03
5.00E+02
PASS
6.06E+03
8.03E+02
8.26E+03
3.85E+03
5.00E+02
PASS
6.05E+03
9.26E+02
8.59E+03
3.51E+03
5.00E+02
PASS
5.91E+03
7.78E+02
8.05E+03
3.78E+03
5.00E+02
PASS
5.79E+03
8.41E+02
8.10E+03
3.48E+03
5.00E+02
PASS
5.83E+03
8.53E+02
8.17E+03
3.49E+03
5.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
164
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Large Signal Voltage Gain1 3 15V (V/mV)
@ VO=+/-14.5V, RL=10kΩ
6.00E+03
5.00E+03
4.00E+03
3.00E+03
2.00E+03
1.00E+03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.77. Plot of Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
165
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.77. Raw data for Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain1 3 15V (V/mV)
@ VO=+/-14.5V, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
3.54E+03
3.41E+03
3.65E+03
4.59E+03
5.46E+03
3.63E+03
3.48E+03
3.68E+03
3.62E+03
5.21E+03
6.31E+03
3.68E+03
24 Hr
Anneal
60
3.42E+03
3.33E+03
3.61E+03
4.51E+03
5.46E+03
3.83E+03
3.84E+03
3.71E+03
3.81E+03
5.29E+03
6.19E+03
3.74E+03
168 Hr
Anneal
70
3.52E+03
3.51E+03
3.89E+03
4.82E+03
5.82E+03
3.73E+03
3.85E+03
3.78E+03
3.81E+03
5.52E+03
6.06E+03
3.76E+03
0
3.99E+03
4.02E+03
4.44E+03
5.70E+03
7.09E+03
4.20E+03
4.15E+03
4.22E+03
4.18E+03
6.30E+03
7.16E+03
4.00E+03
10
3.67E+03
3.55E+03
4.06E+03
5.02E+03
6.03E+03
3.78E+03
3.91E+03
3.78E+03
3.97E+03
5.65E+03
6.34E+03
3.82E+03
Total Dose (krad(Si))
20
30
3.65E+03 3.65E+03
3.39E+03 3.56E+03
3.91E+03 3.85E+03
4.88E+03 4.83E+03
5.90E+03 6.11E+03
3.83E+03 3.93E+03
3.68E+03 3.81E+03
3.88E+03 3.81E+03
3.95E+03 3.84E+03
5.74E+03 5.13E+03
6.31E+03 6.23E+03
3.84E+03 3.78E+03
5.05E+03
1.34E+03
8.71E+03
1.38E+03
4.46E+03
1.05E+03
7.34E+03
1.59E+03
4.34E+03
1.03E+03
7.18E+03
1.51E+03
4.40E+03
1.08E+03
7.36E+03
1.44E+03
4.13E+03
8.76E+02
6.53E+03
1.73E+03
4.07E+03
9.08E+02
6.56E+03
1.58E+03
4.31E+03
9.96E+02
7.04E+03
1.58E+03
4.61E+03
9.46E+02
7.20E+03
2.02E+03
1.00E+03
PASS
4.22E+03
8.06E+02
6.43E+03
2.01E+03
5.00E+02
PASS
4.22E+03
8.60E+02
6.57E+03
1.86E+03
5.00E+02
PASS
4.10E+03
5.75E+02
5.68E+03
2.53E+03
5.00E+02
PASS
3.92E+03
7.21E+02
5.90E+03
1.95E+03
5.00E+02
PASS
4.10E+03
6.70E+02
5.93E+03
2.26E+03
5.00E+02
PASS
4.14E+03
7.73E+02
6.26E+03
2.02E+03
5.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
166
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Large Signal Voltage Gain1 4 15V (V/mV)
@ VO=+/-14.5V, RL=10kΩ
8.00E+03
7.00E+03
6.00E+03
5.00E+03
4.00E+03
3.00E+03
2.00E+03
1.00E+03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.78. Plot of Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
167
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.78. Raw data for Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain1 4 15V (V/mV)
@ VO=+/-14.5V, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
6.37E+03
6.97E+03
4.50E+03
7.15E+03
6.55E+03
6.71E+03
3.95E+03
6.51E+03
4.15E+03
6.18E+03
4.48E+03
4.09E+03
24 Hr
Anneal
60
6.81E+03
6.92E+03
4.22E+03
6.69E+03
6.93E+03
6.77E+03
3.88E+03
7.15E+03
3.93E+03
6.16E+03
4.46E+03
4.18E+03
168 Hr
Anneal
70
6.41E+03
6.59E+03
4.17E+03
6.98E+03
6.64E+03
6.69E+03
4.08E+03
6.10E+03
4.09E+03
6.36E+03
4.44E+03
3.97E+03
0
7.10E+03
7.76E+03
4.39E+03
7.41E+03
7.41E+03
6.90E+03
4.24E+03
7.34E+03
4.17E+03
6.64E+03
4.56E+03
4.03E+03
10
6.78E+03
7.29E+03
4.34E+03
7.05E+03
6.88E+03
6.96E+03
4.34E+03
7.22E+03
4.08E+03
6.91E+03
4.32E+03
3.99E+03
Total Dose (krad(Si))
20
30
6.71E+03 7.09E+03
7.61E+03 7.14E+03
4.31E+03 4.04E+03
7.21E+03 6.61E+03
6.86E+03 6.63E+03
6.58E+03 6.54E+03
4.15E+03 4.07E+03
6.20E+03 6.56E+03
4.13E+03 4.03E+03
6.49E+03 6.71E+03
4.32E+03 4.42E+03
3.99E+03 3.95E+03
6.81E+03
1.38E+03
1.06E+04
3.04E+03
6.47E+03
1.21E+03
9.77E+03
3.16E+03
6.54E+03
1.29E+03
1.01E+04
2.99E+03
6.30E+03
1.29E+03
9.83E+03
2.77E+03
6.31E+03
1.06E+03
9.21E+03
3.40E+03
6.31E+03
1.17E+03
9.53E+03
3.10E+03
6.16E+03
1.13E+03
9.26E+03
3.06E+03
5.86E+03
1.53E+03
1.01E+04
1.66E+03
1.00E+03
PASS
5.90E+03
1.55E+03
1.02E+04
1.65E+03
5.00E+02
PASS
5.51E+03
1.26E+03
8.96E+03
2.05E+03
5.00E+02
PASS
5.58E+03
1.40E+03
9.42E+03
1.75E+03
5.00E+02
PASS
5.50E+03
1.34E+03
9.17E+03
1.83E+03
5.00E+02
PASS
5.58E+03
1.57E+03
9.88E+03
1.28E+03
5.00E+02
PASS
5.46E+03
1.28E+03
8.97E+03
1.96E+03
5.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
168
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Large Signal Voltage Gain2 1 15V (V/mV)
@ VO=+/-10V, RL=2kΩ
2.00E+03
1.50E+03
1.00E+03
5.00E+02
0.00E+00
-5.00E+02
-1.00E+03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.79. Plot of Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
169
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.79. Raw data for Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain2 1 15V (V/mV)
@ VO=+/-10V, RL=2kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Total Dose (krad(Si))
20
30
1.50E+03 1.46E+03
1.10E+03 1.08E+03
1.12E+03 1.11E+03
1.09E+03 1.08E+03
2.46E+03 2.46E+03
1.09E+03 1.09E+03
1.62E+03 1.59E+03
9.94E+02 9.68E+02
2.81E+03 2.65E+03
2.69E+03 2.53E+03
3.15E+03 3.09E+03
1.01E+03 1.01E+03
50
1.47E+03
1.08E+03
1.10E+03
1.10E+03
2.56E+03
1.07E+03
1.57E+03
9.75E+02
2.76E+03
2.56E+03
3.39E+03
1.04E+03
24 Hr
Anneal
60
1.46E+03
1.09E+03
1.11E+03
1.10E+03
2.59E+03
1.08E+03
1.63E+03
1.03E+03
2.74E+03
2.62E+03
3.19E+03
1.04E+03
168 Hr
Anneal
70
1.49E+03
1.10E+03
1.12E+03
1.10E+03
2.56E+03
1.09E+03
1.61E+03
1.03E+03
2.74E+03
2.60E+03
3.16E+03
1.01E+03
0
1.50E+03
1.11E+03
1.12E+03
1.12E+03
2.63E+03
1.08E+03
1.60E+03
1.08E+03
2.77E+03
2.58E+03
3.02E+03
1.00E+03
10
1.51E+03
1.10E+03
1.11E+03
1.11E+03
2.67E+03
1.10E+03
1.63E+03
1.01E+03
2.86E+03
2.73E+03
3.09E+03
1.01E+03
1.50E+03
6.57E+02
3.30E+03
-3.05E+02
1.50E+03
6.75E+02
3.35E+03
-3.50E+02
1.45E+03
5.91E+02
3.07E+03
-1.66E+02
1.44E+03
5.92E+02
3.06E+03
-1.89E+02
1.46E+03
6.35E+02
3.20E+03
-2.80E+02
1.47E+03
6.45E+02
3.24E+03
-2.98E+02
1.47E+03
6.30E+02
3.20E+03
-2.52E+02
1.82E+03
8.09E+02
4.04E+03
-3.95E+02
5.00E+02
PASS
1.87E+03
8.82E+02
4.28E+03
-5.54E+02
2.50E+02
PASS
1.84E+03
8.63E+02
4.21E+03
-5.29E+02
2.50E+02
PASS
1.77E+03
7.88E+02
3.93E+03
-3.95E+02
2.50E+02
PASS
1.79E+03
8.28E+02
4.06E+03
-4.85E+02
2.50E+02
PASS
1.82E+03
8.22E+02
4.07E+03
-4.32E+02
2.50E+02
PASS
1.81E+03
8.13E+02
4.04E+03
-4.15E+02
2.50E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
170
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Large Signal Voltage Gain2 2 15V (V/mV)
@ VO=+/-10V, RL=2kΩ
2.50E+03
2.00E+03
1.50E+03
1.00E+03
5.00E+02
0.00E+00
-5.00E+02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.80. Plot of Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
171
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.80. Raw data for Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain2 2 15V (V/mV)
@ VO=+/-10V, RL=2kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Total Dose (krad(Si))
20
30
9.60E+02 9.54E+02
2.08E+03 2.10E+03
2.12E+03 1.98E+03
2.23E+03 2.07E+03
9.33E+02 9.33E+02
2.31E+03 2.22E+03
2.28E+03 2.48E+03
1.31E+03 1.30E+03
2.34E+03 2.30E+03
2.30E+03 2.27E+03
9.61E+02 1.01E+03
9.33E+02 9.41E+02
50
9.28E+02
2.10E+03
2.02E+03
1.97E+03
9.31E+02
2.12E+03
2.19E+03
1.27E+03
2.14E+03
2.16E+03
9.63E+02
9.43E+02
24 Hr
Anneal
60
9.44E+02
2.02E+03
2.03E+03
2.03E+03
9.21E+02
2.21E+03
2.10E+03
1.28E+03
2.19E+03
2.18E+03
9.60E+02
9.44E+02
168 Hr
Anneal
70
9.45E+02
2.08E+03
2.01E+03
2.07E+03
9.25E+02
2.31E+03
2.17E+03
1.31E+03
2.30E+03
2.28E+03
9.66E+02
9.46E+02
0
9.79E+02
2.20E+03
2.18E+03
2.23E+03
9.55E+02
2.40E+03
2.38E+03
1.34E+03
2.44E+03
2.39E+03
9.64E+02
9.48E+02
10
9.69E+02
2.12E+03
2.16E+03
2.19E+03
9.48E+02
2.33E+03
2.36E+03
1.36E+03
2.36E+03
2.40E+03
9.66E+02
9.40E+02
1.71E+03
6.78E+02
3.57E+03
-1.49E+02
1.68E+03
6.57E+02
3.48E+03
-1.23E+02
1.66E+03
6.58E+02
3.47E+03
-1.39E+02
1.61E+03
6.06E+02
3.27E+03
-5.63E+01
1.59E+03
6.05E+02
3.25E+03
-6.77E+01
1.59E+03
5.97E+02
3.22E+03
-5.06E+01
1.61E+03
6.13E+02
3.29E+03
-7.54E+01
2.19E+03
4.74E+02
3.49E+03
8.89E+02
5.00E+02
PASS
2.16E+03
4.49E+02
3.39E+03
9.30E+02
2.50E+02
PASS
2.11E+03
4.49E+02
3.34E+03
8.79E+02
2.50E+02
PASS
2.11E+03
4.65E+02
3.39E+03
8.36E+02
2.50E+02
PASS
1.98E+03
3.96E+02
3.06E+03
8.93E+02
2.50E+02
PASS
1.99E+03
4.02E+02
3.09E+03
8.91E+02
2.50E+02
PASS
2.07E+03
4.30E+02
3.25E+03
8.91E+02
2.50E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
172
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Large Signal Voltage Gain2 3 15V (V/mV)
@ VO=+/-10V, RL=2kΩ
1.60E+03
1.40E+03
1.20E+03
1.00E+03
8.00E+02
6.00E+02
4.00E+02
2.00E+02
0.00E+00
-2.00E+02
-4.00E+02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.81. Plot of Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
173
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.81. Raw data for Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain2 3 15V (V/mV)
@ VO=+/-10V, RL=2kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Total Dose (krad(Si))
20
30
9.96E+02 9.70E+02
9.29E+02 9.37E+02
1.07E+03 1.06E+03
1.41E+03 1.44E+03
2.18E+03 2.20E+03
9.96E+02 9.59E+02
9.85E+02 9.88E+02
1.03E+03 1.01E+03
9.93E+02 9.72E+02
2.02E+03 2.06E+03
2.31E+03 2.30E+03
9.65E+02 9.70E+02
50
9.57E+02
9.24E+02
1.03E+03
1.37E+03
2.08E+03
9.71E+02
9.62E+02
1.01E+03
9.59E+02
1.90E+03
2.32E+03
9.71E+02
24 Hr
Anneal
60
9.62E+02
9.22E+02
1.04E+03
1.38E+03
2.06E+03
9.81E+02
9.54E+02
9.95E+02
9.52E+02
1.90E+03
2.29E+03
9.62E+02
168 Hr
Anneal
70
9.85E+02
9.13E+02
1.04E+03
1.41E+03
2.18E+03
9.77E+02
9.80E+02
1.01E+03
9.77E+02
1.95E+03
2.30E+03
9.70E+02
0
1.03E+03
9.72E+02
1.12E+03
1.54E+03
2.38E+03
1.06E+03
1.03E+03
1.07E+03
1.03E+03
2.17E+03
2.46E+03
9.82E+02
10
1.01E+03
9.41E+02
1.07E+03
1.43E+03
2.21E+03
1.02E+03
1.00E+03
1.04E+03
9.92E+02
2.10E+03
2.32E+03
9.64E+02
1.41E+03
5.86E+02
3.01E+03
-1.99E+02
1.33E+03
5.25E+02
2.77E+03
-1.09E+02
1.32E+03
5.15E+02
2.73E+03
-9.83E+01
1.32E+03
5.31E+02
2.78E+03
-1.34E+02
1.27E+03
4.84E+02
2.60E+03
-5.68E+01
1.27E+03
4.77E+02
2.58E+03
-3.52E+01
1.31E+03
5.25E+02
2.75E+03
-1.34E+02
1.27E+03
5.01E+02
2.65E+03
-1.01E+02
5.00E+02
PASS
1.23E+03
4.84E+02
2.56E+03
-9.82E+01
2.50E+02
PASS
1.20E+03
4.55E+02
2.45E+03
-4.40E+01
2.50E+02
PASS
1.20E+03
4.82E+02
2.52E+03
-1.26E+02
2.50E+02
PASS
1.16E+03
4.16E+02
2.30E+03
2.21E+01
2.50E+02
PASS
1.16E+03
4.17E+02
2.30E+03
1.45E+01
2.50E+02
PASS
1.18E+03
4.32E+02
2.36E+03
-6.84E+00
2.50E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
174
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Large Signal Voltage Gain2 4 15V (V/mV)
@ VO=+/-10V, RL=2kΩ
2.50E+03
2.00E+03
1.50E+03
1.00E+03
5.00E+02
0.00E+00
-5.00E+02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.82. Plot of Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
175
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.82. Raw data for Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain2 4 15V (V/mV)
@ VO=+/-10V, RL=2kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
2.20E+03
2.29E+03
1.05E+03
2.28E+03
2.25E+03
2.12E+03
1.01E+03
2.12E+03
9.49E+02
2.05E+03
1.08E+03
9.66E+02
24 Hr
Anneal
60
2.24E+03
2.22E+03
1.05E+03
2.24E+03
2.28E+03
2.13E+03
1.01E+03
2.16E+03
9.60E+02
2.01E+03
1.08E+03
9.76E+02
168 Hr
Anneal
70
2.27E+03
2.30E+03
1.05E+03
2.29E+03
2.28E+03
2.03E+03
1.02E+03
2.17E+03
9.68E+02
2.03E+03
1.07E+03
9.64E+02
0
2.40E+03
2.53E+03
1.09E+03
2.42E+03
2.49E+03
2.42E+03
1.03E+03
2.36E+03
9.85E+02
2.18E+03
1.08E+03
9.62E+02
10
2.34E+03
2.40E+03
1.06E+03
2.38E+03
2.30E+03
2.29E+03
1.04E+03
2.24E+03
9.91E+02
2.18E+03
1.07E+03
9.62E+02
Total Dose (krad(Si))
20
30
2.27E+03 2.24E+03
2.39E+03 2.34E+03
1.05E+03 1.05E+03
2.24E+03 2.22E+03
2.33E+03 2.29E+03
2.21E+03 2.15E+03
1.03E+03 1.02E+03
2.29E+03 2.17E+03
9.88E+02 9.59E+02
2.08E+03 2.03E+03
1.07E+03 1.06E+03
9.60E+02 9.64E+02
2.19E+03
6.14E+02
3.87E+03
5.04E+02
2.10E+03
5.81E+02
3.69E+03
5.03E+02
2.06E+03
5.66E+02
3.61E+03
5.03E+02
2.03E+03
5.49E+02
3.53E+03
5.22E+02
2.01E+03
5.38E+02
3.49E+03
5.38E+02
2.01E+03
5.37E+02
3.48E+03
5.34E+02
2.04E+03
5.55E+02
3.56E+03
5.16E+02
1.79E+03
7.24E+02
3.78E+03
-1.91E+02
5.00E+02
PASS
1.75E+03
6.72E+02
3.59E+03
-9.33E+01
2.50E+02
PASS
1.72E+03
6.52E+02
3.51E+03
-6.83E+01
2.50E+02
PASS
1.67E+03
6.19E+02
3.36E+03
-3.06E+01
2.50E+02
PASS
1.65E+03
6.15E+02
3.34E+03
-3.60E+01
2.50E+02
PASS
1.65E+03
6.13E+02
3.33E+03
-2.70E+01
2.50E+02
PASS
1.65E+03
5.98E+02
3.28E+03
5.92E+00
2.50E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
176
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio1 1 15V (dB)
@ VS=+/-15V, VCM=+/-15V
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.83. Plot of Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
177
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.83. Raw data for Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio1 1 15V (dB)
@ VS=+/-15V, VCM=+/-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.00E+02
1.06E+02
1.02E+02
1.25E+02
9.84E+01
1.12E+02
1.03E+02
1.01E+02
1.14E+02
1.08E+02
1.03E+02
1.08E+02
24 Hr
Anneal
60
1.00E+02
1.06E+02
1.02E+02
1.24E+02
9.84E+01
1.12E+02
1.03E+02
1.01E+02
1.14E+02
1.07E+02
1.03E+02
1.08E+02
168 Hr
Anneal
70
1.01E+02
1.06E+02
1.02E+02
1.24E+02
9.85E+01
1.13E+02
1.03E+02
1.02E+02
1.15E+02
1.07E+02
1.03E+02
1.08E+02
0
1.00E+02
1.06E+02
1.02E+02
1.23E+02
9.85E+01
1.13E+02
1.04E+02
1.02E+02
1.13E+02
1.08E+02
1.04E+02
1.09E+02
10
1.00E+02
1.06E+02
1.02E+02
1.24E+02
9.85E+01
1.13E+02
1.04E+02
1.02E+02
1.13E+02
1.08E+02
1.04E+02
1.08E+02
Total Dose (krad(Si))
20
30
1.00E+02 1.00E+02
1.06E+02 1.06E+02
1.02E+02 1.02E+02
1.25E+02 1.25E+02
9.85E+01 9.85E+01
1.13E+02 1.13E+02
1.03E+02 1.03E+02
1.02E+02 1.02E+02
1.13E+02 1.13E+02
1.08E+02 1.08E+02
1.04E+02 1.03E+02
1.08E+02 1.08E+02
1.06E+02
1.01E+01
1.34E+02
7.85E+01
1.06E+02
1.05E+01
1.35E+02
7.76E+01
1.06E+02
1.08E+01
1.36E+02
7.68E+01
1.07E+02
1.08E+01
1.36E+02
7.68E+01
1.06E+02
1.06E+01
1.36E+02
7.72E+01
1.06E+02
1.04E+01
1.35E+02
7.76E+01
1.06E+02
1.05E+01
1.35E+02
7.75E+01
1.08E+02
5.13E+00
1.22E+02
9.38E+01
9.00E+01
PASS
1.08E+02
5.20E+00
1.22E+02
9.36E+01
8.60E+01
PASS
1.08E+02
5.22E+00
1.22E+02
9.34E+01
8.60E+01
PASS
1.08E+02
5.29E+00
1.22E+02
9.32E+01
8.60E+01
PASS
1.08E+02
5.53E+00
1.23E+02
9.25E+01
8.60E+01
PASS
1.08E+02
5.55E+00
1.23E+02
9.24E+01
8.60E+01
PASS
1.08E+02
5.97E+00
1.24E+02
9.16E+01
8.60E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
178
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio1 2 15V (dB)
@ VS=+/-15V, VCM=+/-15V
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.84. Plot of Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
179
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.84. Raw data for Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio1 2 15V (dB)
@ VS=+/-15V, VCM=+/-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
9.97E+01
1.07E+02
1.05E+02
1.02E+02
9.75E+01
1.17E+02
1.17E+02
1.02E+02
9.97E+01
1.14E+02
9.69E+01
9.93E+01
24 Hr
Anneal
60
9.97E+01
1.07E+02
1.05E+02
1.02E+02
9.75E+01
1.17E+02
1.17E+02
1.02E+02
9.97E+01
1.15E+02
9.69E+01
9.92E+01
168 Hr
Anneal
70
9.96E+01
1.08E+02
1.05E+02
1.02E+02
9.76E+01
1.18E+02
1.17E+02
1.02E+02
9.98E+01
1.14E+02
9.69E+01
9.93E+01
0
9.96E+01
1.07E+02
1.05E+02
1.02E+02
9.74E+01
1.19E+02
1.18E+02
1.02E+02
1.00E+02
1.13E+02
9.70E+01
9.94E+01
10
9.96E+01
1.07E+02
1.05E+02
1.02E+02
9.74E+01
1.19E+02
1.18E+02
1.02E+02
9.99E+01
1.13E+02
9.69E+01
9.93E+01
Total Dose (krad(Si))
20
30
9.96E+01 9.97E+01
1.07E+02 1.07E+02
1.05E+02 1.05E+02
1.02E+02 1.02E+02
9.75E+01 9.75E+01
1.19E+02 1.18E+02
1.18E+02 1.18E+02
1.02E+02 1.02E+02
9.99E+01 9.98E+01
1.13E+02 1.13E+02
9.69E+01 9.69E+01
9.93E+01 9.93E+01
1.02E+02
3.96E+00
1.13E+02
9.13E+01
1.02E+02
3.90E+00
1.13E+02
9.14E+01
1.02E+02
3.89E+00
1.13E+02
9.15E+01
1.02E+02
3.89E+00
1.13E+02
9.15E+01
1.02E+02
3.83E+00
1.13E+02
9.16E+01
1.02E+02
3.82E+00
1.13E+02
9.16E+01
1.02E+02
4.06E+00
1.14E+02
9.12E+01
1.11E+02
9.07E+00
1.35E+02
8.56E+01
9.00E+01
PASS
1.10E+02
9.01E+00
1.35E+02
8.57E+01
8.60E+01
PASS
1.10E+02
8.95E+00
1.35E+02
8.58E+01
8.60E+01
PASS
1.10E+02
8.86E+00
1.35E+02
8.60E+01
8.60E+01
PASS
1.10E+02
8.53E+00
1.33E+02
8.66E+01
8.60E+01
PASS
1.10E+02
8.46E+00
1.33E+02
8.67E+01
8.60E+01
PASS
1.10E+02
8.70E+00
1.34E+02
8.63E+01
8.60E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
180
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio1 3 15V (dB)
@ VS=+/-15V, VCM=+/-15V
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.85. Plot of Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
181
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.85. Raw data for Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio1 3 15V (dB)
@ VS=+/-15V, VCM=+/-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.01E+02
1.02E+02
1.00E+02
1.02E+02
1.05E+02
9.85E+01
1.01E+02
1.20E+02
1.07E+02
1.21E+02
1.16E+02
1.06E+02
24 Hr
Anneal
60
1.01E+02
1.02E+02
1.00E+02
1.02E+02
1.05E+02
9.85E+01
1.01E+02
1.20E+02
1.07E+02
1.21E+02
1.16E+02
1.06E+02
168 Hr
Anneal
70
1.01E+02
1.02E+02
1.00E+02
1.02E+02
1.05E+02
9.88E+01
1.01E+02
1.20E+02
1.07E+02
1.25E+02
1.16E+02
1.06E+02
0
1.01E+02
1.02E+02
1.00E+02
1.02E+02
1.05E+02
9.86E+01
1.01E+02
1.26E+02
1.08E+02
1.18E+02
1.17E+02
1.06E+02
10
1.01E+02
1.02E+02
1.00E+02
1.02E+02
1.05E+02
9.85E+01
1.01E+02
1.23E+02
1.08E+02
1.18E+02
1.17E+02
1.06E+02
Total Dose (krad(Si))
20
30
1.01E+02 1.01E+02
1.02E+02 1.02E+02
1.00E+02 1.00E+02
1.02E+02 1.02E+02
1.05E+02 1.05E+02
9.85E+01 9.85E+01
1.01E+02 1.01E+02
1.23E+02 1.22E+02
1.08E+02 1.08E+02
1.19E+02 1.19E+02
1.17E+02 1.17E+02
1.06E+02 1.06E+02
1.02E+02
1.85E+00
1.07E+02
9.69E+01
1.02E+02
1.84E+00
1.07E+02
9.70E+01
1.02E+02
1.83E+00
1.07E+02
9.70E+01
1.02E+02
1.85E+00
1.07E+02
9.70E+01
1.02E+02
1.84E+00
1.07E+02
9.70E+01
1.02E+02
1.83E+00
1.07E+02
9.70E+01
1.02E+02
1.96E+00
1.07E+02
9.68E+01
1.10E+02
1.14E+01
1.41E+02
7.90E+01
9.00E+01
PASS
1.10E+02
1.08E+01
1.39E+02
8.03E+01
8.60E+01
PASS
1.10E+02
1.08E+01
1.40E+02
8.01E+01
8.60E+01
PASS
1.10E+02
1.07E+01
1.39E+02
8.05E+01
8.60E+01
PASS
1.10E+02
1.06E+01
1.39E+02
8.05E+01
8.60E+01
PASS
1.10E+02
1.07E+01
1.39E+02
8.02E+01
8.60E+01
PASS
1.10E+02
1.15E+01
1.42E+02
7.88E+01
8.60E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
182
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio1 4 15V (dB)
@ VS=+/-15V, VCM=+/-15V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.86. Plot of Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
183
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.86. Raw data for Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio1 4 15V (dB)
@ VS=+/-15V, VCM=+/-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.06E+02
1.09E+02
1.32E+02
1.24E+02
1.11E+02
1.17E+02
1.05E+02
1.07E+02
1.12E+02
1.00E+02
1.02E+02
1.03E+02
24 Hr
Anneal
60
1.07E+02
1.09E+02
1.38E+02
1.25E+02
1.11E+02
1.17E+02
1.05E+02
1.07E+02
1.12E+02
1.00E+02
1.02E+02
1.03E+02
168 Hr
Anneal
70
1.07E+02
1.10E+02
1.25E+02
1.22E+02
1.13E+02
1.16E+02
1.05E+02
1.08E+02
1.11E+02
1.00E+02
1.02E+02
1.03E+02
0
1.06E+02
1.10E+02
1.35E+02
1.23E+02
1.11E+02
1.19E+02
1.05E+02
1.09E+02
1.12E+02
1.00E+02
1.02E+02
1.04E+02
10
1.06E+02
1.10E+02
1.32E+02
1.23E+02
1.11E+02
1.19E+02
1.05E+02
1.08E+02
1.12E+02
1.00E+02
1.02E+02
1.03E+02
Total Dose (krad(Si))
20
30
1.06E+02 1.06E+02
1.10E+02 1.10E+02
1.32E+02 1.30E+02
1.23E+02 1.23E+02
1.11E+02 1.11E+02
1.18E+02 1.18E+02
1.05E+02 1.05E+02
1.08E+02 1.08E+02
1.12E+02 1.12E+02
1.00E+02 1.00E+02
1.02E+02 1.02E+02
1.03E+02 1.03E+02
1.17E+02
1.20E+01
1.50E+02
8.42E+01
1.16E+02
1.06E+01
1.45E+02
8.72E+01
1.16E+02
1.08E+01
1.46E+02
8.68E+01
1.16E+02
9.87E+00
1.43E+02
8.89E+01
1.17E+02
1.08E+01
1.46E+02
8.69E+01
1.18E+02
1.33E+01
1.54E+02
8.14E+01
1.15E+02
7.91E+00
1.37E+02
9.35E+01
1.09E+02
7.01E+00
1.28E+02
8.99E+01
9.00E+01
PASS
1.09E+02
6.96E+00
1.28E+02
8.99E+01
8.60E+01
PASS
1.09E+02
6.77E+00
1.27E+02
9.02E+01
8.60E+01
PASS
1.09E+02
6.81E+00
1.27E+02
9.00E+01
8.60E+01
PASS
1.08E+02
6.38E+00
1.26E+02
9.07E+01
8.60E+01
PASS
1.08E+02
6.39E+00
1.26E+02
9.07E+01
8.60E+01
PASS
1.08E+02
6.11E+00
1.25E+02
9.13E+01
8.60E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
184
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.20E+02
CMRR Match1 1 to 4 15V (dB)
@ VS=+/-15V, VCM=+/-15V
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.87. Plot of CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
185
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.87. Raw data for CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
CMRR Match1 1 to 4 15V (dB)
@ VS=+/-15V, VCM=+/-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
9.69E+01
1.16E+02
1.02E+02
1.18E+02
1.01E+02
1.19E+02
1.18E+02
1.08E+02
1.07E+02
1.05E+02
1.19E+02
1.10E+02
24 Hr
Anneal
60
9.70E+01
1.16E+02
1.02E+02
1.18E+02
1.01E+02
1.19E+02
1.18E+02
1.07E+02
1.07E+02
1.05E+02
1.19E+02
1.10E+02
168 Hr
Anneal
70
9.70E+01
1.14E+02
1.02E+02
1.17E+02
1.00E+02
1.24E+02
1.15E+02
1.08E+02
1.07E+02
1.05E+02
1.19E+02
1.10E+02
0
9.67E+01
1.16E+02
1.02E+02
1.17E+02
1.01E+02
1.19E+02
1.19E+02
1.07E+02
1.06E+02
1.05E+02
1.19E+02
1.10E+02
10
9.68E+01
1.16E+02
1.02E+02
1.17E+02
1.01E+02
1.19E+02
1.19E+02
1.07E+02
1.06E+02
1.05E+02
1.19E+02
1.10E+02
Total Dose (krad(Si))
20
30
9.68E+01 9.68E+01
1.16E+02 1.16E+02
1.02E+02 1.02E+02
1.18E+02 1.18E+02
1.01E+02 1.01E+02
1.19E+02 1.19E+02
1.18E+02 1.18E+02
1.07E+02 1.07E+02
1.06E+02 1.07E+02
1.05E+02 1.05E+02
1.19E+02 1.19E+02
1.10E+02 1.10E+02
1.06E+02
9.30E+00
1.32E+02
8.10E+01
1.07E+02
9.38E+00
1.32E+02
8.08E+01
1.07E+02
9.56E+00
1.33E+02
8.04E+01
1.07E+02
9.52E+00
1.33E+02
8.05E+01
1.07E+02
9.69E+00
1.33E+02
8.02E+01
1.07E+02
9.81E+00
1.34E+02
8.00E+01
1.06E+02
9.01E+00
1.31E+02
8.14E+01
1.11E+02
7.25E+00
1.31E+02
9.15E+01
8.40E+01
PASS
1.11E+02
7.10E+00
1.31E+02
9.18E+01
8.30E+01
PASS
1.11E+02
7.00E+00
1.30E+02
9.21E+01
8.30E+01
PASS
1.11E+02
6.89E+00
1.30E+02
9.24E+01
8.30E+01
PASS
1.11E+02
6.59E+00
1.29E+02
9.32E+01
8.30E+01
PASS
1.11E+02
6.52E+00
1.29E+02
9.33E+01
8.30E+01
PASS
1.12E+02
7.92E+00
1.33E+02
8.99E+01
8.30E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
186
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.40E+02
CMRR Match1 2 to 3 15V (dB)
@ VS=+/-15V, VCM=+/-15V
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.88. Plot of CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
187
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.88. Raw data for CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
CMRR Match1 2 to 3 15V (dB)
@ VS=+/-15V, VCM=+/-15V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.18E+02
1.08E+02
1.09E+02
1.25E+02
1.02E+02
9.96E+01
1.02E+02
1.03E+02
1.04E+02
1.20E+02
9.79E+01
1.05E+02
24 Hr
Anneal
60
1.18E+02
1.08E+02
1.09E+02
1.26E+02
1.02E+02
9.96E+01
1.02E+02
1.03E+02
1.04E+02
1.20E+02
9.79E+01
1.05E+02
168 Hr
Anneal
70
1.17E+02
1.08E+02
1.08E+02
1.40E+02
1.02E+02
9.98E+01
1.02E+02
1.03E+02
1.05E+02
1.17E+02
9.79E+01
1.05E+02
0
1.16E+02
1.08E+02
1.09E+02
1.33E+02
1.02E+02
9.94E+01
1.02E+02
1.03E+02
1.04E+02
1.20E+02
9.79E+01
1.05E+02
10
1.16E+02
1.08E+02
1.09E+02
1.30E+02
1.02E+02
9.94E+01
1.02E+02
1.03E+02
1.04E+02
1.20E+02
9.79E+01
1.05E+02
Total Dose (krad(Si))
20
30
1.17E+02 1.17E+02
1.08E+02 1.08E+02
1.09E+02 1.09E+02
1.31E+02 1.30E+02
1.02E+02 1.02E+02
9.94E+01 9.94E+01
1.02E+02 1.02E+02
1.03E+02 1.03E+02
1.04E+02 1.04E+02
1.20E+02 1.19E+02
9.78E+01 9.78E+01
1.05E+02 1.05E+02
1.14E+02
1.21E+01
1.47E+02
8.04E+01
1.13E+02
1.09E+01
1.43E+02
8.32E+01
1.13E+02
1.10E+01
1.43E+02
8.30E+01
1.13E+02
1.08E+01
1.43E+02
8.35E+01
1.12E+02
9.10E+00
1.37E+02
8.75E+01
1.13E+02
9.34E+00
1.38E+02
8.70E+01
1.15E+02
1.48E+01
1.56E+02
7.42E+01
1.06E+02
8.24E+00
1.28E+02
8.32E+01
8.40E+01
PASS
1.06E+02
8.11E+00
1.28E+02
8.34E+01
8.30E+01
PASS
1.06E+02
8.17E+00
1.28E+02
8.33E+01
8.30E+01
PASS
1.06E+02
7.89E+00
1.27E+02
8.39E+01
8.30E+01
PASS
1.06E+02
8.15E+00
1.28E+02
8.34E+01
8.30E+01
PASS
1.06E+02
8.02E+00
1.28E+02
8.38E+01
8.30E+01
PASS
1.05E+02
6.83E+00
1.24E+02
8.67E+01
8.30E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
188
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio1 1 (dB)
@ VS=+/-2V to +/-16V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.89. Plot of Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
189
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.89. Raw data for Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio1 1 (dB)
@ VS=+/-2V to +/-16V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.14E+02
1.08E+02
1.12E+02
1.30E+02
1.19E+02
1.09E+02
1.10E+02
1.10E+02
1.07E+02
1.26E+02
1.07E+02
1.24E+02
24 Hr
Anneal
60
1.14E+02
1.08E+02
1.12E+02
1.30E+02
1.19E+02
1.09E+02
1.10E+02
1.10E+02
1.07E+02
1.26E+02
1.07E+02
1.25E+02
168 Hr
Anneal
70
1.14E+02
1.07E+02
1.12E+02
1.31E+02
1.19E+02
1.09E+02
1.10E+02
1.10E+02
1.07E+02
1.26E+02
1.07E+02
1.24E+02
0
1.14E+02
1.07E+02
1.12E+02
1.30E+02
1.18E+02
1.09E+02
1.10E+02
1.10E+02
1.07E+02
1.26E+02
1.07E+02
1.24E+02
10
1.14E+02
1.07E+02
1.12E+02
1.30E+02
1.18E+02
1.09E+02
1.10E+02
1.10E+02
1.07E+02
1.26E+02
1.07E+02
1.24E+02
Total Dose (krad(Si))
20
30
1.14E+02 1.14E+02
1.07E+02 1.07E+02
1.12E+02 1.12E+02
1.30E+02 1.30E+02
1.18E+02 1.19E+02
1.09E+02 1.09E+02
1.10E+02 1.10E+02
1.10E+02 1.10E+02
1.07E+02 1.07E+02
1.26E+02 1.26E+02
1.07E+02 1.07E+02
1.24E+02 1.24E+02
1.16E+02
8.78E+00
1.40E+02
9.23E+01
1.16E+02
8.74E+00
1.40E+02
9.24E+01
1.16E+02
8.73E+00
1.40E+02
9.24E+01
1.16E+02
8.70E+00
1.40E+02
9.25E+01
1.16E+02
8.59E+00
1.40E+02
9.28E+01
1.17E+02
8.73E+00
1.40E+02
9.26E+01
1.16E+02
8.84E+00
1.41E+02
9.22E+01
1.12E+02
7.87E+00
1.34E+02
9.08E+01
9.00E+01
PASS
1.12E+02
7.88E+00
1.34E+02
9.09E+01
9.00E+01
PASS
1.12E+02
7.85E+00
1.34E+02
9.10E+01
9.00E+01
PASS
1.12E+02
7.67E+00
1.33E+02
9.13E+01
9.00E+01
PASS
1.13E+02
7.70E+00
1.34E+02
9.14E+01
9.00E+01
PASS
1.12E+02
7.59E+00
1.33E+02
9.17E+01
9.00E+01
PASS
1.13E+02
7.74E+00
1.34E+02
9.13E+01
9.00E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
190
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio1 2 (dB)
@ VS=+/-2V to +/-16V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.90. Plot of Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
191
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.90. Raw data for Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio1 2 (dB)
@ VS=+/-2V to +/-16V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.28E+02
1.16E+02
1.13E+02
1.13E+02
1.25E+02
1.08E+02
1.08E+02
1.14E+02
1.07E+02
1.05E+02
1.36E+02
1.14E+02
24 Hr
Anneal
60
1.27E+02
1.16E+02
1.13E+02
1.13E+02
1.25E+02
1.08E+02
1.08E+02
1.13E+02
1.07E+02
1.06E+02
1.35E+02
1.14E+02
168 Hr
Anneal
70
1.28E+02
1.16E+02
1.13E+02
1.13E+02
1.25E+02
1.08E+02
1.08E+02
1.14E+02
1.07E+02
1.06E+02
1.36E+02
1.14E+02
0
1.27E+02
1.16E+02
1.13E+02
1.13E+02
1.24E+02
1.08E+02
1.08E+02
1.13E+02
1.06E+02
1.05E+02
1.35E+02
1.14E+02
10
1.28E+02
1.16E+02
1.13E+02
1.13E+02
1.25E+02
1.08E+02
1.08E+02
1.14E+02
1.06E+02
1.05E+02
1.35E+02
1.14E+02
Total Dose (krad(Si))
20
30
1.27E+02 1.28E+02
1.16E+02 1.16E+02
1.13E+02 1.13E+02
1.13E+02 1.13E+02
1.25E+02 1.25E+02
1.08E+02 1.08E+02
1.08E+02 1.08E+02
1.14E+02 1.14E+02
1.06E+02 1.06E+02
1.05E+02 1.05E+02
1.35E+02 1.35E+02
1.14E+02 1.14E+02
1.19E+02
6.74E+00
1.37E+02
1.00E+02
1.19E+02
6.84E+00
1.38E+02
1.00E+02
1.19E+02
6.77E+00
1.37E+02
1.00E+02
1.19E+02
6.90E+00
1.38E+02
1.00E+02
1.19E+02
6.90E+00
1.38E+02
1.00E+02
1.19E+02
6.83E+00
1.38E+02
1.00E+02
1.19E+02
6.81E+00
1.38E+02
1.00E+02
1.08E+02
3.12E+00
1.17E+02
9.96E+01
9.00E+01
PASS
1.08E+02
3.12E+00
1.17E+02
9.97E+01
9.00E+01
PASS
1.08E+02
3.15E+00
1.17E+02
9.96E+01
9.00E+01
PASS
1.08E+02
3.16E+00
1.17E+02
9.95E+01
9.00E+01
PASS
1.08E+02
3.13E+00
1.17E+02
9.97E+01
9.00E+01
PASS
1.08E+02
3.07E+00
1.17E+02
9.99E+01
9.00E+01
PASS
1.08E+02
3.11E+00
1.17E+02
9.97E+01
9.00E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
192
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio1 3 (dB)
@ VS=+/-2V to +/-16V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.91. Plot of Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
193
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.91. Raw data for Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio1 3 (dB)
@ VS=+/-2V to +/-16V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.10E+02
1.18E+02
1.14E+02
1.21E+02
1.11E+02
1.13E+02
1.03E+02
1.13E+02
1.09E+02
1.22E+02
1.13E+02
1.13E+02
24 Hr
Anneal
60
1.10E+02
1.18E+02
1.14E+02
1.21E+02
1.11E+02
1.13E+02
1.03E+02
1.13E+02
1.09E+02
1.22E+02
1.13E+02
1.13E+02
168 Hr
Anneal
70
1.10E+02
1.18E+02
1.13E+02
1.21E+02
1.10E+02
1.13E+02
1.03E+02
1.12E+02
1.09E+02
1.22E+02
1.13E+02
1.13E+02
0
1.09E+02
1.18E+02
1.13E+02
1.21E+02
1.10E+02
1.13E+02
1.03E+02
1.12E+02
1.09E+02
1.22E+02
1.13E+02
1.13E+02
10
1.10E+02
1.18E+02
1.13E+02
1.21E+02
1.10E+02
1.13E+02
1.03E+02
1.12E+02
1.09E+02
1.22E+02
1.13E+02
1.13E+02
Total Dose (krad(Si))
20
30
1.10E+02 1.10E+02
1.18E+02 1.18E+02
1.13E+02 1.13E+02
1.21E+02 1.21E+02
1.10E+02 1.10E+02
1.13E+02 1.13E+02
1.03E+02 1.03E+02
1.12E+02 1.12E+02
1.09E+02 1.09E+02
1.22E+02 1.22E+02
1.13E+02 1.13E+02
1.13E+02 1.13E+02
1.14E+02
4.92E+00
1.28E+02
1.01E+02
1.15E+02
4.94E+00
1.28E+02
1.01E+02
1.15E+02
4.93E+00
1.28E+02
1.01E+02
1.15E+02
4.87E+00
1.28E+02
1.01E+02
1.15E+02
4.87E+00
1.28E+02
1.01E+02
1.15E+02
4.84E+00
1.28E+02
1.01E+02
1.15E+02
4.90E+00
1.28E+02
1.01E+02
1.12E+02
7.16E+00
1.31E+02
9.21E+01
9.00E+01
PASS
1.12E+02
7.07E+00
1.31E+02
9.24E+01
9.00E+01
PASS
1.12E+02
7.02E+00
1.31E+02
9.25E+01
9.00E+01
PASS
1.12E+02
7.02E+00
1.31E+02
9.25E+01
9.00E+01
PASS
1.12E+02
6.98E+00
1.31E+02
9.27E+01
9.00E+01
PASS
1.12E+02
7.02E+00
1.31E+02
9.27E+01
9.00E+01
PASS
1.12E+02
7.01E+00
1.31E+02
9.26E+01
9.00E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
194
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio1 4 (dB)
@ VS=+/-2V to +/-16V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.92. Plot of Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
195
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.92. Raw data for Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio1 4 (dB)
@ VS=+/-2V to +/-16V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.10E+02
1.08E+02
1.21E+02
1.14E+02
1.07E+02
1.10E+02
1.20E+02
1.11E+02
1.15E+02
1.19E+02
1.04E+02
1.07E+02
24 Hr
Anneal
60
1.10E+02
1.08E+02
1.21E+02
1.14E+02
1.07E+02
1.10E+02
1.20E+02
1.11E+02
1.15E+02
1.19E+02
1.04E+02
1.07E+02
168 Hr
Anneal
70
1.10E+02
1.08E+02
1.21E+02
1.14E+02
1.07E+02
1.10E+02
1.20E+02
1.11E+02
1.15E+02
1.19E+02
1.04E+02
1.07E+02
0
1.10E+02
1.08E+02
1.20E+02
1.14E+02
1.07E+02
1.10E+02
1.20E+02
1.10E+02
1.15E+02
1.19E+02
1.04E+02
1.07E+02
10
1.10E+02
1.08E+02
1.20E+02
1.14E+02
1.07E+02
1.10E+02
1.20E+02
1.10E+02
1.15E+02
1.19E+02
1.04E+02
1.07E+02
Total Dose (krad(Si))
20
30
1.10E+02 1.10E+02
1.08E+02 1.08E+02
1.21E+02 1.21E+02
1.14E+02 1.14E+02
1.07E+02 1.07E+02
1.10E+02 1.10E+02
1.20E+02 1.20E+02
1.10E+02 1.10E+02
1.15E+02 1.15E+02
1.19E+02 1.19E+02
1.04E+02 1.04E+02
1.07E+02 1.07E+02
1.12E+02
5.35E+00
1.27E+02
9.72E+01
1.12E+02
5.38E+00
1.27E+02
9.72E+01
1.12E+02
5.45E+00
1.27E+02
9.70E+01
1.12E+02
5.52E+00
1.27E+02
9.69E+01
1.12E+02
5.56E+00
1.27E+02
9.69E+01
1.12E+02
5.63E+00
1.28E+02
9.67E+01
1.12E+02
5.44E+00
1.27E+02
9.71E+01
1.15E+02
4.71E+00
1.28E+02
1.02E+02
9.00E+01
PASS
1.15E+02
4.69E+00
1.28E+02
1.02E+02
9.00E+01
PASS
1.15E+02
4.65E+00
1.28E+02
1.02E+02
9.00E+01
PASS
1.15E+02
4.66E+00
1.28E+02
1.02E+02
9.00E+01
PASS
1.15E+02
4.61E+00
1.28E+02
1.02E+02
9.00E+01
PASS
1.15E+02
4.56E+00
1.28E+02
1.02E+02
9.00E+01
PASS
1.15E+02
4.64E+00
1.28E+02
1.02E+02
9.00E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
196
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.93. Plot of PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
197
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.93. Raw data for PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
PSRR Match1 1 to 4 (dB)
@ VS=+/-2V to +/-16V
Device
557
563
564
567
569
570
571
572
573
574
584
585
0
1.06E+02
1.29E+02
1.16E+02
1.13E+02
1.10E+02
1.27E+02
1.13E+02
1.37E+02
1.11E+02
1.16E+02
1.14E+02
1.09E+02
Biased Statistics
Average Biased
1.15E+02
Std Dev Biased
8.89E+00
Ps90%/90% (+KTL) Biased
1.39E+02
Ps90%/90% (-KTL) Biased
9.03E+01
Un-Biased Statistics
Average Un-Biased
1.21E+02
Std Dev Un-Biased
1.10E+01
Ps90%/90% (+KTL) Un-Biased 1.51E+02
Ps90%/90% (-KTL) Un-Biased
9.09E+01
Specification MIN
8.30E+01
Status
PASS
50
1.06E+02
1.30E+02
1.16E+02
1.13E+02
1.10E+02
1.28E+02
1.13E+02
1.41E+02
1.11E+02
1.16E+02
1.14E+02
1.09E+02
24 Hr
Anneal
60
1.06E+02
1.29E+02
1.16E+02
1.13E+02
1.10E+02
1.27E+02
1.14E+02
1.38E+02
1.11E+02
1.16E+02
1.14E+02
1.09E+02
168 Hr
Anneal
70
1.06E+02
1.28E+02
1.16E+02
1.13E+02
1.10E+02
1.28E+02
1.13E+02
1.42E+02
1.11E+02
1.16E+02
1.14E+02
1.09E+02
1.15E+02
9.01E+00
1.39E+02
9.00E+01
1.15E+02
9.04E+00
1.40E+02
9.00E+01
1.15E+02
9.03E+00
1.40E+02
9.01E+01
1.15E+02
8.64E+00
1.38E+02
9.09E+01
1.21E+02
1.16E+01
1.53E+02
8.95E+01
8.30E+01
PASS
1.22E+02
1.25E+01
1.56E+02
8.77E+01
8.30E+01
PASS
1.21E+02
1.13E+01
1.52E+02
9.03E+01
8.30E+01
PASS
1.22E+02
1.27E+01
1.57E+02
8.71E+01
8.30E+01
PASS
10
1.06E+02
1.29E+02
1.16E+02
1.13E+02
1.10E+02
1.27E+02
1.13E+02
1.38E+02
1.11E+02
1.16E+02
1.13E+02
1.09E+02
Total Dose (krad(Si))
20
30
1.06E+02 1.06E+02
1.29E+02 1.29E+02
1.16E+02 1.16E+02
1.13E+02 1.13E+02
1.10E+02 1.10E+02
1.27E+02 1.27E+02
1.13E+02 1.13E+02
1.42E+02 1.39E+02
1.11E+02 1.11E+02
1.16E+02 1.16E+02
1.14E+02 1.13E+02
1.09E+02 1.09E+02
1.15E+02
8.72E+00
1.38E+02
9.06E+01
1.15E+02
9.01E+00
1.39E+02
9.00E+01
1.21E+02
1.12E+01
1.52E+02
9.05E+01
8.30E+01
PASS
1.22E+02
1.29E+01
1.57E+02
8.67E+01
8.30E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
198
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.94. Plot of PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
199
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.94. Raw data for PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
PSRR Match1 2 to 3 (dB)
@ VS=+/-2V to +/-16V
Device
557
563
564
567
569
570
571
572
573
574
584
585
0
1.08E+02
1.11E+02
1.45E+02
1.17E+02
1.09E+02
1.04E+02
1.10E+02
1.29E+02
1.19E+02
1.04E+02
1.14E+02
1.30E+02
Biased Statistics
Average Biased
1.18E+02
Std Dev Biased
1.56E+01
Ps90%/90% (+KTL) Biased
1.61E+02
Ps90%/90% (-KTL) Biased
7.54E+01
Un-Biased Statistics
Average Un-Biased
1.13E+02
Std Dev Un-Biased
1.06E+01
Ps90%/90% (+KTL) Un-Biased 1.42E+02
Ps90%/90% (-KTL) Un-Biased
8.42E+01
Specification MIN
8.30E+01
Status
PASS
50
1.09E+02
1.11E+02
1.43E+02
1.17E+02
1.09E+02
1.04E+02
1.10E+02
1.31E+02
1.19E+02
1.04E+02
1.14E+02
1.30E+02
24 Hr
Anneal
60
1.09E+02
1.11E+02
1.41E+02
1.17E+02
1.09E+02
1.04E+02
1.10E+02
1.33E+02
1.19E+02
1.04E+02
1.14E+02
1.29E+02
168 Hr
Anneal
70
1.09E+02
1.11E+02
1.47E+02
1.17E+02
1.09E+02
1.04E+02
1.10E+02
1.31E+02
1.19E+02
1.04E+02
1.14E+02
1.29E+02
1.18E+02
1.51E+01
1.60E+02
7.66E+01
1.18E+02
1.46E+01
1.58E+02
7.78E+01
1.17E+02
1.36E+01
1.55E+02
8.03E+01
1.19E+02
1.61E+01
1.63E+02
7.44E+01
1.13E+02
1.08E+01
1.43E+02
8.37E+01
8.30E+01
PASS
1.14E+02
1.15E+01
1.45E+02
8.23E+01
8.30E+01
PASS
1.14E+02
1.21E+01
1.47E+02
8.09E+01
8.30E+01
PASS
1.14E+02
1.12E+01
1.44E+02
8.28E+01
8.30E+01
PASS
10
1.09E+02
1.11E+02
1.47E+02
1.17E+02
1.09E+02
1.04E+02
1.10E+02
1.29E+02
1.19E+02
1.04E+02
1.14E+02
1.30E+02
Total Dose (krad(Si))
20
30
1.09E+02 1.09E+02
1.11E+02 1.11E+02
1.41E+02 1.44E+02
1.17E+02 1.17E+02
1.09E+02 1.09E+02
1.04E+02 1.04E+02
1.10E+02 1.10E+02
1.29E+02 1.29E+02
1.19E+02 1.19E+02
1.04E+02 1.04E+02
1.14E+02 1.14E+02
1.28E+02 1.30E+02
1.19E+02
1.63E+01
1.63E+02
7.40E+01
1.17E+02
1.38E+01
1.55E+02
7.96E+01
1.13E+02
1.08E+01
1.43E+02
8.37E+01
8.30E+01
PASS
1.13E+02
1.08E+01
1.43E+02
8.37E+01
8.30E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
200
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
0.00E+00
+Short-Circuit Current1 1 15V (A)
@ VS=+/-15V, VOUT=0V
-5.00E-03
-1.00E-02
-1.50E-02
-2.00E-02
-2.50E-02
-3.00E-02
-3.50E-02
-4.00E-02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.95. Plot of +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
201
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.95. Raw data for +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Short-Circuit Current1 1 15V (A)
@ VS=+/-15V, VOUT=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-3.71E-02
-3.59E-02
-3.58E-02
-3.61E-02
-3.70E-02
-3.53E-02
-3.54E-02
-3.70E-02
-3.47E-02
-3.55E-02
-3.63E-02
-3.73E-02
Total Dose (krad(Si))
20
30
-3.64E-02 -3.62E-02
-3.50E-02 -3.49E-02
-3.50E-02 -3.49E-02
-3.53E-02 -3.52E-02
-3.61E-02 -3.60E-02
-3.50E-02 -3.48E-02
-3.50E-02 -3.48E-02
-3.65E-02 -3.62E-02
-3.43E-02 -3.41E-02
-3.52E-02 -3.50E-02
-3.65E-02 -3.66E-02
-3.76E-02 -3.74E-02
10
-3.67E-02
-3.53E-02
-3.53E-02
-3.57E-02
-3.66E-02
-3.52E-02
-3.52E-02
-3.66E-02
-3.44E-02
-3.54E-02
-3.64E-02
-3.74E-02
50
-3.53E-02
-3.42E-02
-3.42E-02
-3.44E-02
-3.51E-02
-3.38E-02
-3.38E-02
-3.52E-02
-3.31E-02
-3.40E-02
-3.62E-02
-3.71E-02
24 Hr
Anneal
60
-3.52E-02
-3.40E-02
-3.39E-02
-3.43E-02
-3.51E-02
-3.38E-02
-3.38E-02
-3.51E-02
-3.31E-02
-3.39E-02
-3.61E-02
-3.69E-02
168 Hr
Anneal
70
-3.59E-02
-3.47E-02
-3.47E-02
-3.50E-02
-3.58E-02
-3.43E-02
-3.43E-02
-3.57E-02
-3.36E-02
-3.45E-02
-3.63E-02
-3.73E-02
-3.64E-02 -3.59E-02 -3.56E-02 -3.54E-02 -3.46E-02 -3.45E-02 -3.52E-02
6.14E-04 6.85E-04 6.31E-04 6.07E-04 5.53E-04 6.20E-04 5.72E-04
-3.47E-02 -3.40E-02 -3.38E-02 -3.38E-02 -3.31E-02 -3.28E-02 -3.37E-02
-3.80E-02 -3.78E-02 -3.73E-02 -3.71E-02 -3.61E-02 -3.62E-02 -3.68E-02
-3.56E-02
8.50E-04
-3.32E-02
-3.79E-02
-1.50E-02
PASS
-3.54E-02
8.11E-04
-3.32E-02
-3.76E-02
-1.00E-02
PASS
-3.52E-02
8.09E-04
-3.30E-02
-3.74E-02
-1.00E-02
PASS
-3.49E-02
7.82E-04
-3.28E-02
-3.71E-02
-1.00E-02
PASS
-3.40E-02
7.67E-04
-3.19E-02
-3.61E-02
-1.00E-02
PASS
An ISO 9001:2008 and DSCC Certified Company
202
-3.39E-02
7.48E-04
-3.19E-02
-3.60E-02
-1.00E-02
PASS
-3.45E-02
7.70E-04
-3.24E-02
-3.66E-02
-1.00E-02
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
0.00E+00
+Short-Circuit Current1 2 15V (A)
@ VS=+/-15V, VOUT=0V
-5.00E-03
-1.00E-02
-1.50E-02
-2.00E-02
-2.50E-02
-3.00E-02
-3.50E-02
-4.00E-02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.96. Plot of +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
203
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.96. Raw data for +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Short-Circuit Current1 2 15V (A)
@ VS=+/-15V, VOUT=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-3.95E-02
-3.63E-02
-3.63E-02
-3.58E-02
-3.62E-02
-3.63E-02
-3.55E-02
-3.73E-02
-3.41E-02
-3.72E-02
-3.64E-02
-3.59E-02
Total Dose (krad(Si))
20
30
-3.87E-02 -3.85E-02
-3.55E-02 -3.54E-02
-3.54E-02 -3.53E-02
-3.49E-02 -3.48E-02
-3.53E-02 -3.52E-02
-3.58E-02 -3.56E-02
-3.51E-02 -3.48E-02
-3.68E-02 -3.65E-02
-3.37E-02 -3.34E-02
-3.68E-02 -3.65E-02
-3.65E-02 -3.66E-02
-3.61E-02 -3.60E-02
10
-3.91E-02
-3.57E-02
-3.58E-02
-3.54E-02
-3.58E-02
-3.61E-02
-3.53E-02
-3.70E-02
-3.38E-02
-3.70E-02
-3.65E-02
-3.60E-02
50
-3.76E-02
-3.46E-02
-3.46E-02
-3.39E-02
-3.43E-02
-3.46E-02
-3.38E-02
-3.55E-02
-3.24E-02
-3.56E-02
-3.62E-02
-3.56E-02
24 Hr
Anneal
60
-3.75E-02
-3.44E-02
-3.44E-02
-3.39E-02
-3.43E-02
-3.46E-02
-3.38E-02
-3.55E-02
-3.24E-02
-3.55E-02
-3.61E-02
-3.54E-02
168 Hr
Anneal
70
-3.82E-02
-3.52E-02
-3.52E-02
-3.46E-02
-3.50E-02
-3.52E-02
-3.44E-02
-3.61E-02
-3.30E-02
-3.61E-02
-3.64E-02
-3.58E-02
-3.68E-02 -3.63E-02 -3.60E-02 -3.58E-02 -3.50E-02 -3.49E-02 -3.56E-02
1.52E-03 1.55E-03 1.55E-03 1.53E-03 1.48E-03 1.49E-03 1.47E-03
-3.26E-02 -3.21E-02 -3.17E-02 -3.17E-02 -3.10E-02 -3.08E-02 -3.16E-02
-4.10E-02 -4.06E-02 -4.02E-02 -4.00E-02 -3.91E-02 -3.90E-02 -3.97E-02
-3.61E-02
1.33E-03
-3.24E-02
-3.97E-02
-1.50E-02
PASS
-3.58E-02
1.35E-03
-3.21E-02
-3.95E-02
-1.00E-02
PASS
-3.56E-02
1.33E-03
-3.20E-02
-3.93E-02
-1.00E-02
PASS
-3.54E-02
1.31E-03
-3.18E-02
-3.90E-02
-1.00E-02
PASS
-3.44E-02
1.30E-03
-3.08E-02
-3.80E-02
-1.00E-02
PASS
An ISO 9001:2008 and DSCC Certified Company
204
-3.44E-02
1.28E-03
-3.08E-02
-3.79E-02
-1.00E-02
PASS
-3.49E-02
1.29E-03
-3.14E-02
-3.85E-02
-1.00E-02
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
0.00E+00
+Short-Circuit Current1 3 15V (A)
@ VS=+/-15V, VOUT=0V
-5.00E-03
-1.00E-02
-1.50E-02
-2.00E-02
-2.50E-02
-3.00E-02
-3.50E-02
-4.00E-02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.97. Plot of +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
205
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.97. Raw data for +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Short-Circuit Current1 3 15V (A)
@ VS=+/-15V, VOUT=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-4.01E-02
-3.62E-02
-3.71E-02
-3.66E-02
-3.69E-02
-3.65E-02
-3.63E-02
-3.80E-02
-3.44E-02
-3.82E-02
-3.65E-02
-3.64E-02
Total Dose (krad(Si))
20
30
-3.93E-02 -3.92E-02
-3.54E-02 -3.52E-02
-3.63E-02 -3.62E-02
-3.58E-02 -3.56E-02
-3.59E-02 -3.58E-02
-3.61E-02 -3.59E-02
-3.59E-02 -3.56E-02
-3.75E-02 -3.72E-02
-3.40E-02 -3.38E-02
-3.79E-02 -3.76E-02
-3.66E-02 -3.67E-02
-3.67E-02 -3.66E-02
10
-3.97E-02
-3.56E-02
-3.67E-02
-3.62E-02
-3.64E-02
-3.64E-02
-3.61E-02
-3.76E-02
-3.42E-02
-3.81E-02
-3.66E-02
-3.66E-02
50
-3.82E-02
-3.45E-02
-3.55E-02
-3.48E-02
-3.50E-02
-3.48E-02
-3.46E-02
-3.61E-02
-3.28E-02
-3.66E-02
-3.63E-02
-3.62E-02
24 Hr
Anneal
60
-3.81E-02
-3.43E-02
-3.52E-02
-3.47E-02
-3.49E-02
-3.48E-02
-3.46E-02
-3.61E-02
-3.28E-02
-3.65E-02
-3.63E-02
-3.60E-02
168 Hr
Anneal
70
-3.88E-02
-3.51E-02
-3.60E-02
-3.54E-02
-3.57E-02
-3.54E-02
-3.52E-02
-3.67E-02
-3.34E-02
-3.71E-02
-3.65E-02
-3.64E-02
-3.74E-02 -3.69E-02 -3.65E-02 -3.64E-02 -3.56E-02 -3.55E-02 -3.62E-02
1.57E-03 1.62E-03 1.59E-03 1.58E-03 1.51E-03 1.53E-03 1.50E-03
-3.31E-02 -3.25E-02 -3.22E-02 -3.21E-02 -3.14E-02 -3.13E-02 -3.21E-02
-4.17E-02 -4.14E-02 -4.09E-02 -4.07E-02 -3.97E-02 -3.97E-02 -4.03E-02
-3.67E-02
1.51E-03
-3.25E-02
-4.08E-02
-1.50E-02
PASS
-3.65E-02
1.53E-03
-3.23E-02
-4.06E-02
-1.00E-02
PASS
-3.63E-02
1.51E-03
-3.21E-02
-4.04E-02
-1.00E-02
PASS
-3.60E-02
1.48E-03
-3.19E-02
-4.01E-02
-1.00E-02
PASS
-3.50E-02
1.48E-03
-3.09E-02
-3.90E-02
-1.00E-02
PASS
An ISO 9001:2008 and DSCC Certified Company
206
-3.49E-02
1.45E-03
-3.10E-02
-3.89E-02
-1.00E-02
PASS
-3.55E-02
1.46E-03
-3.15E-02
-3.96E-02
-1.00E-02
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
0.00E+00
+Short-Circuit Current1 4 15V (A)
@ VS=+/-15V, VOUT=0V
-5.00E-03
-1.00E-02
-1.50E-02
-2.00E-02
-2.50E-02
-3.00E-02
-3.50E-02
-4.00E-02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.98. Plot of +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
207
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.98. Raw data for +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Short-Circuit Current1 4 15V (A)
@ VS=+/-15V, VOUT=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-3.77E-02
-3.67E-02
-3.64E-02
-3.71E-02
-3.76E-02
-3.63E-02
-3.62E-02
-3.76E-02
-3.53E-02
-3.64E-02
-3.71E-02
-3.83E-02
Total Dose (krad(Si))
20
30
-3.70E-02 -3.68E-02
-3.58E-02 -3.57E-02
-3.56E-02 -3.55E-02
-3.63E-02 -3.61E-02
-3.67E-02 -3.66E-02
-3.59E-02 -3.57E-02
-3.57E-02 -3.55E-02
-3.72E-02 -3.69E-02
-3.49E-02 -3.47E-02
-3.61E-02 -3.59E-02
-3.72E-02 -3.74E-02
-3.86E-02 -3.84E-02
10
-3.73E-02
-3.60E-02
-3.60E-02
-3.67E-02
-3.72E-02
-3.62E-02
-3.60E-02
-3.73E-02
-3.50E-02
-3.63E-02
-3.72E-02
-3.84E-02
50
-3.59E-02
-3.49E-02
-3.48E-02
-3.53E-02
-3.57E-02
-3.47E-02
-3.45E-02
-3.58E-02
-3.37E-02
-3.49E-02
-3.69E-02
-3.81E-02
24 Hr
Anneal
60
-3.59E-02
-3.47E-02
-3.45E-02
-3.52E-02
-3.57E-02
-3.47E-02
-3.45E-02
-3.58E-02
-3.37E-02
-3.48E-02
-3.69E-02
-3.79E-02
168 Hr
Anneal
70
-3.65E-02
-3.55E-02
-3.53E-02
-3.59E-02
-3.64E-02
-3.53E-02
-3.50E-02
-3.64E-02
-3.43E-02
-3.54E-02
-3.71E-02
-3.82E-02
-3.71E-02 -3.66E-02 -3.63E-02 -3.61E-02 -3.53E-02 -3.52E-02 -3.59E-02
5.71E-04 6.42E-04 5.82E-04 5.58E-04 4.98E-04 5.74E-04 5.26E-04
-3.55E-02 -3.49E-02 -3.47E-02 -3.46E-02 -3.40E-02 -3.36E-02 -3.45E-02
-3.87E-02 -3.84E-02 -3.79E-02 -3.77E-02 -3.67E-02 -3.68E-02 -3.74E-02
-3.64E-02
8.34E-04
-3.41E-02
-3.87E-02
-1.50E-02
PASS
-3.62E-02
8.15E-04
-3.39E-02
-3.84E-02
-1.00E-02
PASS
-3.60E-02
8.05E-04
-3.38E-02
-3.82E-02
-1.00E-02
PASS
-3.57E-02
7.81E-04
-3.36E-02
-3.79E-02
-1.00E-02
PASS
-3.47E-02
7.67E-04
-3.26E-02
-3.68E-02
-1.00E-02
PASS
An ISO 9001:2008 and DSCC Certified Company
208
-3.47E-02
7.57E-04
-3.26E-02
-3.68E-02
-1.00E-02
PASS
-3.53E-02
7.64E-04
-3.32E-02
-3.74E-02
-1.00E-02
PASS
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
7.00E-02
-Short-Circuit Current1 1 15V (A)
@ VS=+/-15V, VOUT=0V
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.99. Plot of -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
209
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.99. Raw data for -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
-Short-Circuit Current1 1 15V (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS=+/-15V, VOUT=0V
Device
0
10
20
30
50
60
70
557 5.83E-02 5.84E-02 5.83E-02 5.81E-02 5.86E-02 5.87E-02 5.85E-02
563 5.88E-02 5.90E-02 5.87E-02 5.85E-02 5.89E-02 5.92E-02 5.88E-02
564 5.81E-02 5.79E-02 5.78E-02 5.75E-02 5.79E-02 5.83E-02 5.79E-02
567 5.81E-02 5.77E-02 5.77E-02 5.76E-02 5.81E-02 5.83E-02 5.80E-02
569 5.88E-02 5.85E-02 5.86E-02 5.84E-02 5.90E-02 5.91E-02 5.88E-02
570 5.81E-02 5.80E-02 5.79E-02 5.77E-02 5.83E-02 5.83E-02 5.81E-02
571 5.79E-02 5.80E-02 5.78E-02 5.76E-02 5.81E-02 5.82E-02 5.80E-02
572 5.73E-02 5.76E-02 5.72E-02 5.71E-02 5.76E-02 5.77E-02 5.75E-02
573 5.75E-02 5.78E-02 5.73E-02 5.72E-02 5.77E-02 5.78E-02 5.76E-02
574 5.80E-02 5.80E-02 5.77E-02 5.75E-02 5.80E-02 5.82E-02 5.79E-02
584 5.82E-02 5.80E-02 5.80E-02 5.78E-02 5.85E-02 5.86E-02 5.82E-02
585 5.79E-02 5.77E-02 5.74E-02 5.77E-02 5.82E-02 5.86E-02 5.80E-02
Biased Statistics
Average Biased
5.84E-02 5.83E-02 5.82E-02 5.80E-02 5.85E-02 5.87E-02 5.84E-02
Std Dev Biased
3.67E-04 5.16E-04 4.58E-04 4.46E-04 4.82E-04 4.45E-04 4.12E-04
Ps90%/90% (+KTL) Biased
5.94E-02 5.97E-02 5.95E-02 5.93E-02 5.98E-02 5.99E-02 5.95E-02
Ps90%/90% (-KTL) Biased
5.74E-02 5.69E-02 5.70E-02 5.68E-02 5.71E-02 5.75E-02 5.73E-02
Un-Biased Statistics
Average Un-Biased
5.77E-02 5.79E-02 5.76E-02 5.74E-02 5.79E-02 5.80E-02 5.78E-02
Std Dev Un-Biased
3.58E-04 1.96E-04 3.07E-04 2.74E-04 3.04E-04 2.61E-04 2.90E-04
Ps90%/90% (+KTL) Un-Biased
5.87E-02 5.84E-02 5.84E-02 5.82E-02 5.88E-02 5.88E-02 5.86E-02
Ps90%/90% (-KTL) Un-Biased
5.68E-02 5.73E-02 5.67E-02 5.67E-02 5.71E-02 5.73E-02 5.70E-02
Specification MIN
1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
210
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
-Short-Circuit Current1 2 15V (A)
@ VS=+/-15V, VOUT=0V
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.100. Plot of -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
211
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.100. Raw data for -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
-Short-Circuit Current1 2 15V (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS=+/-15V, VOUT=0V
Device
0
10
20
30
50
60
70
557 5.73E-02 5.74E-02 5.73E-02 5.71E-02 5.76E-02 5.77E-02 5.75E-02
563 5.65E-02 5.67E-02 5.64E-02 5.62E-02 5.66E-02 5.69E-02 5.64E-02
564 5.64E-02 5.61E-02 5.60E-02 5.58E-02 5.61E-02 5.66E-02 5.62E-02
567 5.68E-02 5.65E-02 5.65E-02 5.64E-02 5.69E-02 5.71E-02 5.68E-02
569 5.62E-02 5.58E-02 5.59E-02 5.58E-02 5.63E-02 5.64E-02 5.61E-02
570 5.65E-02 5.65E-02 5.63E-02 5.61E-02 5.68E-02 5.68E-02 5.66E-02
571 5.63E-02 5.64E-02 5.62E-02 5.60E-02 5.65E-02 5.65E-02 5.64E-02
572 5.66E-02 5.69E-02 5.65E-02 5.64E-02 5.69E-02 5.71E-02 5.68E-02
573 5.59E-02 5.61E-02 5.57E-02 5.55E-02 5.61E-02 5.62E-02 5.59E-02
574 5.69E-02 5.70E-02 5.67E-02 5.65E-02 5.70E-02 5.72E-02 5.69E-02
584 5.62E-02 5.61E-02 5.61E-02 5.59E-02 5.65E-02 5.66E-02 5.62E-02
585 5.64E-02 5.62E-02 5.60E-02 5.62E-02 5.67E-02 5.70E-02 5.65E-02
Biased Statistics
Average Biased
5.66E-02 5.65E-02 5.64E-02 5.63E-02 5.67E-02 5.69E-02 5.66E-02
Std Dev Biased
4.48E-04 5.86E-04 5.51E-04 5.39E-04 5.65E-04 5.04E-04 5.60E-04
Ps90%/90% (+KTL) Biased
5.79E-02 5.81E-02 5.79E-02 5.78E-02 5.82E-02 5.83E-02 5.81E-02
Ps90%/90% (-KTL) Biased
5.54E-02 5.49E-02 5.49E-02 5.48E-02 5.51E-02 5.55E-02 5.51E-02
Un-Biased Statistics
Average Un-Biased
5.64E-02 5.66E-02 5.63E-02 5.61E-02 5.66E-02 5.67E-02 5.65E-02
Std Dev Un-Biased
3.86E-04 3.61E-04 3.63E-04 3.83E-04 3.65E-04 4.18E-04 3.85E-04
Ps90%/90% (+KTL) Un-Biased
5.75E-02 5.76E-02 5.73E-02 5.72E-02 5.76E-02 5.79E-02 5.76E-02
Ps90%/90% (-KTL) Un-Biased
5.54E-02 5.56E-02 5.53E-02 5.51E-02 5.56E-02 5.56E-02 5.55E-02
Specification MIN
1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
212
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
-Short-Circuit Current1 3 15V (A)
@ VS=+/-15V, VOUT=0V
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.101. Plot of -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
213
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.101. Raw data for -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
-Short-Circuit Current1 3 15V (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS=+/-15V, VOUT=0V
Device
0
10
20
30
50
60
70
557 5.73E-02 5.74E-02 5.73E-02 5.72E-02 5.76E-02 5.78E-02 5.74E-02
563 5.66E-02 5.68E-02 5.65E-02 5.63E-02 5.67E-02 5.69E-02 5.66E-02
564 5.64E-02 5.62E-02 5.61E-02 5.59E-02 5.62E-02 5.66E-02 5.62E-02
567 5.68E-02 5.65E-02 5.65E-02 5.64E-02 5.69E-02 5.70E-02 5.68E-02
569 5.61E-02 5.57E-02 5.58E-02 5.57E-02 5.62E-02 5.64E-02 5.60E-02
570 5.68E-02 5.67E-02 5.66E-02 5.64E-02 5.70E-02 5.70E-02 5.68E-02
571 5.66E-02 5.67E-02 5.65E-02 5.63E-02 5.68E-02 5.68E-02 5.67E-02
572 5.68E-02 5.71E-02 5.67E-02 5.66E-02 5.71E-02 5.72E-02 5.70E-02
573 5.58E-02 5.62E-02 5.57E-02 5.56E-02 5.61E-02 5.62E-02 5.60E-02
574 5.71E-02 5.72E-02 5.69E-02 5.67E-02 5.72E-02 5.74E-02 5.71E-02
584 5.64E-02 5.62E-02 5.62E-02 5.60E-02 5.67E-02 5.67E-02 5.64E-02
585 5.66E-02 5.63E-02 5.61E-02 5.64E-02 5.68E-02 5.72E-02 5.66E-02
Biased Statistics
Average Biased
5.66E-02 5.65E-02 5.64E-02 5.63E-02 5.67E-02 5.69E-02 5.66E-02
Std Dev Biased
4.59E-04 6.26E-04 5.73E-04 5.65E-04 5.80E-04 5.32E-04 5.63E-04
Ps90%/90% (+KTL) Biased
5.79E-02 5.82E-02 5.80E-02 5.78E-02 5.83E-02 5.84E-02 5.81E-02
Ps90%/90% (-KTL) Biased
5.54E-02 5.48E-02 5.49E-02 5.47E-02 5.51E-02 5.55E-02 5.50E-02
Un-Biased Statistics
Average Un-Biased
5.66E-02 5.68E-02 5.65E-02 5.63E-02 5.68E-02 5.69E-02 5.67E-02
Std Dev Un-Biased
4.84E-04 4.03E-04 4.43E-04 4.33E-04 4.44E-04 4.60E-04 4.42E-04
Ps90%/90% (+KTL) Un-Biased
5.79E-02 5.79E-02 5.77E-02 5.75E-02 5.80E-02 5.82E-02 5.79E-02
Ps90%/90% (-KTL) Un-Biased
5.53E-02 5.57E-02 5.53E-02 5.51E-02 5.56E-02 5.57E-02 5.55E-02
Specification MIN
1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
214
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
-Short-Circuit Current1 4 15V (A)
@ VS=+/-15V, VOUT=0V
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.102. Plot of -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
215
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.102. Raw data for -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
-Short-Circuit Current1 4 15V (A)
Anneal
Anneal
Total Dose (krad(Si))
@ VS=+/-15V, VOUT=0V
Device
0
10
20
30
50
60
70
557 5.59E-02 5.60E-02 5.60E-02 5.58E-02 5.62E-02 5.63E-02 5.61E-02
563 5.65E-02 5.67E-02 5.64E-02 5.62E-02 5.65E-02 5.69E-02 5.64E-02
564 5.58E-02 5.55E-02 5.54E-02 5.52E-02 5.55E-02 5.60E-02 5.56E-02
567 5.56E-02 5.53E-02 5.53E-02 5.52E-02 5.57E-02 5.58E-02 5.56E-02
569 5.65E-02 5.61E-02 5.62E-02 5.61E-02 5.66E-02 5.67E-02 5.63E-02
570 5.57E-02 5.56E-02 5.55E-02 5.53E-02 5.59E-02 5.59E-02 5.57E-02
571 5.55E-02 5.56E-02 5.54E-02 5.52E-02 5.57E-02 5.57E-02 5.56E-02
572 5.51E-02 5.54E-02 5.50E-02 5.49E-02 5.54E-02 5.55E-02 5.53E-02
573 5.51E-02 5.54E-02 5.50E-02 5.48E-02 5.53E-02 5.54E-02 5.52E-02
574 5.56E-02 5.56E-02 5.54E-02 5.53E-02 5.56E-02 5.59E-02 5.56E-02
584 5.57E-02 5.55E-02 5.55E-02 5.53E-02 5.60E-02 5.60E-02 5.57E-02
585 5.54E-02 5.51E-02 5.49E-02 5.51E-02 5.56E-02 5.59E-02 5.54E-02
Biased Statistics
Average Biased
5.61E-02 5.59E-02 5.59E-02 5.57E-02 5.61E-02 5.63E-02 5.60E-02
Std Dev Biased
4.01E-04 5.37E-04 4.72E-04 4.55E-04 4.90E-04 4.68E-04 4.16E-04
Ps90%/90% (+KTL) Biased
5.72E-02 5.74E-02 5.72E-02 5.69E-02 5.74E-02 5.76E-02 5.71E-02
Ps90%/90% (-KTL) Biased
5.50E-02 5.45E-02 5.46E-02 5.44E-02 5.48E-02 5.51E-02 5.49E-02
Un-Biased Statistics
Average Un-Biased
5.54E-02 5.55E-02 5.53E-02 5.51E-02 5.56E-02 5.57E-02 5.55E-02
Std Dev Un-Biased
2.85E-04 1.31E-04 2.45E-04 2.32E-04 2.50E-04 2.27E-04 2.25E-04
Ps90%/90% (+KTL) Un-Biased
5.62E-02 5.59E-02 5.59E-02 5.57E-02 5.63E-02 5.63E-02 5.61E-02
Ps90%/90% (-KTL) Un-Biased
5.46E-02 5.52E-02 5.46E-02 5.45E-02 5.49E-02 5.51E-02 5.49E-02
Specification MIN
1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
216
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Ps90%/90% (+KTL) Biased
+Supply Current 5V (A) @ VS=+5V
9.00E-03
8.80E-03
8.60E-03
8.40E-03
8.20E-03
8.00E-03
7.80E-03
7.60E-03
7.40E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.103. Plot of +Supply Current 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
217
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.103. Raw data for +Supply Current 5V (A) @ VS=+5V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
+Supply Current 5V (A)
@ VS=+5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
0
7.72E-03
7.79E-03
7.79E-03
7.73E-03
7.73E-03
7.72E-03
7.63E-03
7.79E-03
7.58E-03
7.71E-03
7.70E-03
7.76E-03
10
7.70E-03
7.75E-03
7.77E-03
7.72E-03
7.71E-03
7.71E-03
7.60E-03
7.76E-03
7.57E-03
7.69E-03
7.71E-03
7.76E-03
Total Dose (krad(Si))
20
30
7.68E-03 7.67E-03
7.74E-03 7.74E-03
7.75E-03 7.76E-03
7.69E-03 7.69E-03
7.68E-03 7.67E-03
7.69E-03 7.68E-03
7.59E-03 7.59E-03
7.75E-03 7.74E-03
7.55E-03 7.54E-03
7.69E-03 7.67E-03
7.71E-03 7.71E-03
7.80E-03 7.76E-03
50
7.62E-03
7.68E-03
7.70E-03
7.63E-03
7.62E-03
7.61E-03
7.53E-03
7.67E-03
7.47E-03
7.61E-03
7.68E-03
7.74E-03
24 Hr
Anneal
60
7.61E-03
7.67E-03
7.68E-03
7.62E-03
7.61E-03
7.61E-03
7.51E-03
7.66E-03
7.47E-03
7.60E-03
7.66E-03
7.71E-03
168 Hr
Anneal
70
7.63E-03
7.71E-03
7.72E-03
7.65E-03
7.64E-03
7.64E-03
7.53E-03
7.69E-03
7.49E-03
7.63E-03
7.68E-03
7.74E-03
Biased Statistics
Average Biased
7.75E-03 7.73E-03 7.71E-03 7.71E-03 7.65E-03 7.64E-03 7.67E-03
Std Dev Biased
3.57E-05 3.01E-05 3.44E-05 4.03E-05 3.90E-05 3.56E-05 4.13E-05
Ps90%/90% (+KTL) Biased
7.85E-03 7.81E-03 7.80E-03 7.82E-03 7.75E-03 7.73E-03 7.78E-03
Ps90%/90% (-KTL) Biased
7.65E-03 7.65E-03 7.61E-03 7.60E-03 7.54E-03 7.54E-03 7.56E-03
Un-Biased Statistics
Average Un-Biased
7.69E-03 7.67E-03 7.65E-03 7.64E-03 7.58E-03 7.57E-03 7.60E-03
Std Dev Un-Biased
8.32E-05 8.14E-05 8.18E-05 8.03E-05 7.98E-05 8.07E-05 8.26E-05
Ps90%/90% (+KTL) Un-Biased
7.91E-03 7.89E-03 7.88E-03 7.86E-03 7.80E-03 7.79E-03 7.82E-03
Ps90%/90% (-KTL) Un-Biased
7.46E-03 7.44E-03 7.43E-03 7.42E-03 7.36E-03 7.35E-03 7.37E-03
Specification MAX
8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
218
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
-7.40E-03
-Supply Current 5V (A) @ VS=+5V
-7.60E-03
-7.80E-03
-8.00E-03
-8.20E-03
-8.40E-03
-8.60E-03
-8.80E-03
-9.00E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.104. Plot of -Supply Current 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average
of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the
average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid
and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated
under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application
of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or
post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
219
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.104. Raw data for -Supply Current 5V (A) @ VS=+5V versus total dose, including the statistical
analysis, specification and the status of the testing (pass/fail).
-Supply Current 5V (A)
@ VS=+5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
0
-7.72E-03
-7.79E-03
-7.79E-03
-7.73E-03
-7.72E-03
-7.72E-03
-7.62E-03
-7.78E-03
-7.58E-03
-7.71E-03
-7.70E-03
-7.76E-03
Biased Statistics
Average Biased
-7.75E-03
Std Dev Biased
3.60E-05
Ps90%/90% (+KTL) Biased
-7.65E-03
Ps90%/90% (-KTL) Biased
-7.85E-03
Un-Biased Statistics
Average Un-Biased
-7.68E-03
Std Dev Un-Biased
8.20E-05
Ps90%/90% (+KTL) Un-Biased -7.46E-03
Ps90%/90% (-KTL) Un-Biased
-7.91E-03
Specification MIN
-8.80E-03
Status
PASS
10
-7.69E-03
-7.75E-03
-7.77E-03
-7.72E-03
-7.70E-03
-7.71E-03
-7.60E-03
-7.76E-03
-7.56E-03
-7.68E-03
-7.71E-03
-7.75E-03
Total Dose (krad(Si))
20
30
-7.68E-03 -7.67E-03
-7.74E-03 -7.73E-03
-7.75E-03 -7.75E-03
-7.69E-03 -7.68E-03
-7.68E-03 -7.67E-03
-7.69E-03 -7.68E-03
-7.59E-03 -7.58E-03
-7.75E-03 -7.74E-03
-7.55E-03 -7.54E-03
-7.69E-03 -7.67E-03
-7.71E-03 -7.72E-03
-7.80E-03 -7.76E-03
50
-7.61E-03
-7.68E-03
-7.70E-03
-7.62E-03
-7.61E-03
-7.61E-03
-7.53E-03
-7.67E-03
-7.47E-03
-7.61E-03
-7.68E-03
-7.74E-03
24 Hr
Anneal
60
-7.61E-03
-7.67E-03
-7.67E-03
-7.61E-03
-7.60E-03
-7.61E-03
-7.51E-03
-7.66E-03
-7.46E-03
-7.60E-03
-7.66E-03
-7.71E-03
168 Hr
Anneal
70
-7.63E-03
-7.71E-03
-7.72E-03
-7.64E-03
-7.64E-03
-7.63E-03
-7.53E-03
-7.69E-03
-7.48E-03
-7.62E-03
-7.68E-03
-7.74E-03
-7.72E-03 -7.70E-03 -7.70E-03 -7.64E-03 -7.63E-03 -7.67E-03
3.07E-05 3.42E-05 3.98E-05 3.95E-05 3.53E-05 4.11E-05
-7.64E-03 -7.61E-03 -7.59E-03 -7.54E-03 -7.54E-03 -7.56E-03
-7.81E-03 -7.80E-03 -7.81E-03 -7.75E-03 -7.73E-03 -7.78E-03
-7.66E-03
8.05E-05
-7.44E-03
-7.88E-03
-8.80E-03
PASS
-7.65E-03
8.06E-05
-7.43E-03
-7.87E-03
-8.80E-03
PASS
-7.64E-03
8.02E-05
-7.42E-03
-7.86E-03
-8.80E-03
PASS
-7.58E-03
7.90E-05
-7.36E-03
-7.79E-03
-8.80E-03
PASS
An ISO 9001:2008 and DSCC Certified Company
220
-7.57E-03
7.99E-05
-7.35E-03
-7.79E-03
-8.80E-03
PASS
-7.59E-03
8.15E-05
-7.37E-03
-7.82E-03
-8.80E-03
PASS
Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.105. Plot of Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
221
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.105. Raw data for Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage4 1 5V (V)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-1.97E-04
-7.81E-05
4.79E-05
5.03E-05
-1.40E-04
1.82E-04
-2.52E-04
2.48E-04
8.94E-05
-7.19E-06
-3.53E-04
1.81E-04
10
-2.05E-04
-8.42E-05
3.98E-05
4.15E-05
-1.44E-04
1.71E-04
-2.58E-04
2.35E-04
8.42E-05
-1.59E-05
-3.53E-04
1.75E-04
Total Dose (krad(Si))
20
30
-2.07E-04 -2.11E-04
-8.65E-05 -8.74E-05
4.09E-05 4.26E-05
3.76E-05 3.93E-05
-1.47E-04 -1.47E-04
1.68E-04 1.66E-04
-2.60E-04 -2.62E-04
2.33E-04 2.33E-04
8.18E-05 7.99E-05
-1.37E-05 -1.65E-05
-3.54E-04 -3.54E-04
1.81E-04 1.77E-04
50
-2.17E-04
-9.49E-05
3.34E-05
3.93E-05
-1.51E-04
1.57E-04
-2.68E-04
2.28E-04
7.30E-05
-2.70E-05
-3.55E-04
1.75E-04
24 Hr
Anneal
60
-2.15E-04
-9.35E-05
3.12E-05
3.76E-05
-1.52E-04
1.54E-04
-2.67E-04
2.24E-04
7.06E-05
-2.69E-05
-3.58E-04
1.71E-04
168 Hr
Anneal
70
-2.11E-04
-1.09E-04
3.53E-05
3.47E-05
-1.50E-04
1.59E-04
-2.71E-04
2.22E-04
6.11E-05
-2.66E-05
-3.57E-04
1.75E-04
-6.34E-05 -7.06E-05 -7.25E-05 -7.27E-05 -7.80E-05 -7.83E-05 -7.99E-05
1.11E-04 1.10E-04 1.10E-04 1.13E-04 1.13E-04 1.11E-04 1.11E-04
2.41E-04 2.32E-04 2.30E-04 2.36E-04 2.32E-04 2.27E-04 2.24E-04
-3.68E-04 -3.73E-04 -3.75E-04 -3.81E-04 -3.88E-04 -3.84E-04 -3.84E-04
5.21E-05
1.95E-04
5.87E-04
-4.83E-04
-8.00E-04
PASS
8.00E-04
PASS
4.32E-05
1.93E-04
5.73E-04
-4.86E-04
-9.50E-04
PASS
9.50E-04
PASS
4.19E-05
1.93E-04
5.70E-04
-4.86E-04
-9.50E-04
PASS
9.50E-04
PASS
4.01E-05
1.93E-04
5.69E-04
-4.89E-04
-9.50E-04
PASS
9.50E-04
PASS
3.26E-05
1.93E-04
5.62E-04
-4.96E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
222
3.09E-05
1.91E-04
5.54E-04
-4.93E-04
-9.50E-04
PASS
9.50E-04
PASS
2.91E-05
1.93E-04
5.57E-04
-4.99E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.106. Plot of Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
223
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.106. Raw data for Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage4 2 5V (V)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-1.64E-04
-1.81E-04
1.65E-05
-9.45E-05
-1.82E-05
4.40E-06
1.49E-04
4.59E-05
-7.76E-05
6.20E-05
-2.91E-04
9.88E-05
10
-1.71E-04
-1.89E-04
9.83E-06
-9.73E-05
-1.95E-05
-3.45E-06
1.43E-04
3.05E-05
-8.36E-05
5.49E-05
-2.92E-04
9.35E-05
Total Dose (krad(Si))
20
30
-1.72E-04 -1.71E-04
-1.89E-04 -1.92E-04
1.12E-05 1.20E-05
-9.94E-05 -9.73E-05
-2.10E-05 -2.04E-05
-4.54E-06 -5.62E-06
1.43E-04 1.46E-04
2.96E-05 2.76E-05
-8.25E-05 -8.48E-05
5.51E-05 5.43E-05
-2.95E-04 -2.93E-04
9.48E-05 9.27E-05
50
-1.72E-04
-1.93E-04
3.44E-06
-1.05E-04
-1.99E-05
-7.91E-06
1.42E-04
2.42E-05
-8.33E-05
4.62E-05
-2.93E-04
9.88E-05
24 Hr
Anneal
60
-1.72E-04
-1.89E-04
6.58E-06
-1.07E-04
-2.07E-05
-9.60E-06
1.43E-04
2.37E-05
-8.49E-05
4.97E-05
-2.89E-04
9.06E-05
168 Hr
Anneal
70
-1.79E-04
-1.84E-04
1.27E-05
-8.70E-05
-2.61E-05
-6.83E-06
1.28E-04
2.05E-05
-9.13E-05
4.96E-05
-2.91E-04
9.53E-05
-8.83E-05 -9.33E-05 -9.40E-05 -9.37E-05 -9.74E-05 -9.65E-05 -9.26E-05
8.70E-05 8.83E-05 8.87E-05 8.97E-05 8.81E-05 8.77E-05 8.85E-05
1.50E-04 1.49E-04 1.49E-04 1.52E-04 1.44E-04 1.44E-04 1.50E-04
-3.27E-04 -3.35E-04 -3.37E-04 -3.40E-04 -3.39E-04 -3.37E-04 -3.35E-04
3.68E-05
8.28E-05
2.64E-04
-1.90E-04
-8.00E-04
PASS
8.00E-04
PASS
2.83E-05
8.29E-05
2.56E-04
-1.99E-04
-9.50E-04
PASS
9.50E-04
PASS
2.81E-05
8.24E-05
2.54E-04
-1.98E-04
-9.50E-04
PASS
9.50E-04
PASS
2.74E-05
8.43E-05
2.59E-04
-2.04E-04
-9.50E-04
PASS
9.50E-04
PASS
2.43E-05
8.22E-05
2.50E-04
-2.01E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
224
2.43E-05
8.33E-05
2.53E-04
-2.04E-04
-9.50E-04
PASS
9.50E-04
PASS
1.99E-05
7.99E-05
2.39E-04
-1.99E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.107. Plot of Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
225
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.107. Raw data for Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage4 3 5V (V)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
3.74E-04
-7.14E-05
2.52E-05
5.23E-05
-9.87E-05
-1.65E-04
-1.90E-07
2.74E-04
1.74E-04
5.02E-05
4.19E-04
8.34E-05
10
3.64E-04
-7.67E-05
2.03E-05
5.08E-05
-1.03E-04
-1.72E-04
-9.97E-06
2.65E-04
1.70E-04
4.52E-05
4.22E-04
8.19E-05
Total Dose (krad(Si))
20
30
3.60E-04 3.53E-04
-7.95E-05 -8.57E-05
1.39E-05 1.25E-05
4.52E-05 4.04E-05
-1.07E-04 -1.13E-04
-1.74E-04 -1.75E-04
-1.25E-05 -1.72E-05
2.60E-04 2.54E-04
1.69E-04 1.68E-04
4.24E-05 3.78E-05
4.21E-04 4.21E-04
7.95E-05 7.66E-05
50
3.45E-04
-8.25E-05
5.97E-06
3.83E-05
-1.14E-04
-1.80E-04
-2.47E-05
2.45E-04
1.59E-04
3.17E-05
4.20E-04
8.17E-05
24 Hr
Anneal
60
3.43E-04
-8.25E-05
2.47E-06
3.62E-05
-1.22E-04
-1.82E-04
-2.45E-05
2.44E-04
1.60E-04
3.04E-05
4.17E-04
7.21E-05
168 Hr
Anneal
70
3.41E-04
-7.89E-05
-3.33E-06
3.28E-05
-1.12E-04
-1.77E-04
-1.21E-05
2.34E-04
1.57E-04
2.49E-05
4.19E-04
7.84E-05
5.64E-05 5.10E-05 4.65E-05 4.15E-05 3.86E-05 3.54E-05 3.59E-05
1.89E-04 1.86E-04 1.86E-04 1.85E-04 1.82E-04 1.83E-04 1.80E-04
5.74E-04 5.61E-04 5.58E-04 5.50E-04 5.38E-04 5.38E-04 5.30E-04
-4.61E-04 -4.59E-04 -4.65E-04 -4.67E-04 -4.61E-04 -4.67E-04 -4.58E-04
6.66E-05
1.68E-04
5.28E-04
-3.95E-04
-8.00E-04
PASS
8.00E-04
PASS
5.97E-05
1.68E-04
5.20E-04
-4.01E-04
-9.50E-04
PASS
9.50E-04
PASS
5.70E-05
1.67E-04
5.16E-04
-4.02E-04
-9.50E-04
PASS
9.50E-04
PASS
5.35E-05
1.66E-04
5.10E-04
-4.03E-04
-9.50E-04
PASS
9.50E-04
PASS
4.62E-05
1.65E-04
4.98E-04
-4.06E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
226
4.57E-05
1.65E-04
4.99E-04
-4.07E-04
-9.50E-04
PASS
9.50E-04
PASS
4.52E-05
1.59E-04
4.81E-04
-3.90E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.108. Plot of Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
227
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.108. Raw data for Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage4 4 5V (V)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
8.92E-06
7.00E-05
1.88E-04
1.99E-04
-2.09E-04
1.41E-04
1.75E-04
3.74E-05
1.41E-04
-2.16E-04
2.38E-04
-1.22E-04
10
-1.16E-06
6.11E-05
1.83E-04
1.94E-04
-2.12E-04
1.30E-04
1.67E-04
2.60E-05
1.34E-04
-2.23E-04
2.37E-04
-1.22E-04
Total Dose (krad(Si))
20
30
-3.45E-06 -4.90E-06
5.88E-05 5.98E-05
1.85E-04 1.84E-04
1.94E-04 1.95E-04
-2.14E-04 -2.19E-04
1.30E-04 1.32E-04
1.69E-04 1.66E-04
2.25E-05 2.28E-05
1.37E-04 1.40E-04
-2.22E-04 -2.22E-04
2.38E-04 2.38E-04
-1.21E-04 -1.20E-04
50
-1.03E-05
5.36E-05
1.75E-04
1.89E-04
-2.14E-04
1.37E-04
1.63E-04
1.65E-05
1.40E-04
-2.21E-04
2.34E-04
-1.21E-04
24 Hr
Anneal
60
-1.19E-05
5.05E-05
1.70E-04
1.86E-04
-2.16E-04
1.33E-04
1.59E-04
1.46E-05
1.35E-04
-2.23E-04
2.30E-04
-1.24E-04
168 Hr
Anneal
70
-6.35E-06
6.13E-05
1.75E-04
1.87E-04
-2.13E-04
1.29E-04
1.63E-04
2.08E-05
1.26E-04
-2.33E-04
2.34E-04
-1.22E-04
5.13E-05 4.50E-05 4.41E-05 4.29E-05 3.87E-05 3.58E-05 4.10E-05
1.66E-04 1.66E-04 1.67E-04 1.69E-04 1.64E-04 1.63E-04 1.63E-04
5.07E-04 5.00E-04 5.01E-04 5.06E-04 4.88E-04 4.84E-04 4.88E-04
-4.05E-04 -4.10E-04 -4.13E-04 -4.20E-04 -4.11E-04 -4.12E-04 -4.07E-04
5.56E-05
1.60E-04
4.95E-04
-3.84E-04
-8.00E-04
PASS
8.00E-04
PASS
4.68E-05
1.60E-04
4.86E-04
-3.92E-04
-9.50E-04
PASS
9.50E-04
PASS
4.72E-05
1.61E-04
4.87E-04
-3.93E-04
-9.50E-04
PASS
9.50E-04
PASS
4.81E-05
1.60E-04
4.88E-04
-3.92E-04
-9.50E-04
PASS
9.50E-04
PASS
4.71E-05
1.60E-04
4.87E-04
-3.93E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
228
4.35E-05
1.59E-04
4.80E-04
-3.93E-04
-9.50E-04
PASS
9.50E-04
PASS
4.12E-05
1.62E-04
4.86E-04
-4.03E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-08
6.00E-08
4.00E-08
2.00E-08
0.00E+00
-2.00E-08
-4.00E-08
-6.00E-08
-8.00E-08
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.109. Plot of Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
229
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.109. Raw data for Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current4 1 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
2.39E-09
-3.77E-09
3.00E-11
5.62E-09
1.96E-09
5.10E-10
-5.46E-09
2.93E-09
-1.83E-09
5.34E-09
-7.95E-09
1.96E-09
10
2.13E-09
-4.36E-09
-1.70E-10
5.36E-09
7.40E-10
3.70E-10
-5.73E-09
2.85E-09
-1.81E-09
5.08E-09
-8.68E-09
1.60E-10
Total Dose (krad(Si))
20
30
1.30E-09 8.90E-10
-4.45E-09 -5.06E-09
-1.01E-09 -1.93E-09
4.73E-09 5.01E-09
1.40E-10 -7.20E-10
7.70E-10 7.60E-10
-6.33E-09 -6.59E-09
2.77E-09 3.26E-09
-1.98E-09 -1.94E-09
5.26E-09 4.76E-09
-9.01E-09 -9.38E-09
1.30E-10 1.20E-10
50
-3.00E-10
-6.30E-09
-3.25E-09
3.99E-09
-2.13E-09
7.60E-10
-6.70E-09
2.80E-09
-2.05E-09
5.49E-09
-9.57E-09
4.00E-11
24 Hr
Anneal
60
-1.28E-09
-7.04E-09
-4.45E-09
3.68E-09
-2.59E-09
5.40E-10
-7.64E-09
2.00E-09
-3.22E-09
4.55E-09
-9.76E-09
-9.00E-11
168 Hr
Anneal
70
2.80E-10
-5.72E-09
-2.63E-09
3.48E-09
-1.16E-09
5.50E-10
-6.39E-09
1.96E-09
-2.41E-09
5.35E-09
-9.83E-09
-2.50E-10
1.25E-09 7.40E-10 1.42E-10 -3.62E-10 -1.60E-09 -2.34E-09 -1.15E-09
3.45E-09 3.54E-09 3.35E-09 3.71E-09 3.81E-09 4.00E-09 3.41E-09
1.07E-08 1.04E-08 9.32E-09 9.81E-09 8.85E-09 8.63E-09 8.20E-09
-8.21E-09 -8.97E-09 -9.03E-09 -1.05E-08 -1.20E-08 -1.33E-08 -1.05E-08
2.98E-10
4.19E-09
1.18E-08
-1.12E-08
-6.50E-08
PASS
6.50E-08
PASS
1.52E-10
4.19E-09
1.16E-08
-1.13E-08
-6.50E-08
PASS
6.50E-08
PASS
9.80E-11
4.47E-09
1.24E-08
-1.22E-08
-6.50E-08
PASS
6.50E-08
PASS
5.00E-11
4.50E-09
1.24E-08
-1.23E-08
-6.50E-08
PASS
6.50E-08
PASS
6.00E-11
4.68E-09
1.29E-08
-1.28E-08
-6.50E-08
PASS
6.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
230
-7.54E-10
4.77E-09
1.23E-08
-1.38E-08
-6.50E-08
PASS
6.50E-08
PASS
-1.88E-10
4.45E-09
1.20E-08
-1.24E-08
-6.50E-08
PASS
6.50E-08
PASS
Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-08
6.00E-08
4.00E-08
2.00E-08
0.00E+00
-2.00E-08
-4.00E-08
-6.00E-08
-8.00E-08
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.110. Plot of Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
231
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.110. Raw data for Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current4 2 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
2.81E-09
-2.27E-09
-2.33E-09
6.50E-10
2.72E-09
-1.63E-09
-1.60E-10
2.20E-09
1.46E-09
-1.14E-09
3.03E-09
2.51E-09
10
2.38E-09
-2.88E-09
-3.31E-09
-3.30E-10
2.78E-09
-1.53E-09
-8.60E-10
1.91E-09
1.08E-09
-1.25E-09
2.52E-09
7.50E-10
Total Dose (krad(Si))
20
30
2.05E-09 1.68E-09
-3.24E-09 -3.88E-09
-4.18E-09 -4.80E-09
-1.80E-10 -7.90E-10
3.30E-09 2.80E-09
-2.10E-09 -1.94E-09
-8.80E-10 -1.20E-10
2.23E-09 1.94E-09
8.00E-10 8.30E-10
-1.55E-09 -1.52E-09
1.98E-09 1.74E-09
6.50E-10 6.20E-10
50
7.30E-10
-4.26E-09
-5.29E-09
-1.69E-09
2.65E-09
-2.62E-09
-1.29E-09
2.97E-09
1.00E-09
-1.32E-09
1.64E-09
6.00E-10
24 Hr
Anneal
60
-2.10E-10
-5.31E-09
-6.13E-09
-2.16E-09
2.11E-09
-3.06E-09
-2.42E-09
1.84E-09
1.00E-10
-2.12E-09
1.41E-09
5.70E-10
168 Hr
Anneal
70
4.50E-10
-4.16E-09
-4.67E-09
-1.76E-09
1.37E-09
-2.47E-09
-1.83E-09
2.16E-09
6.60E-10
-1.75E-09
1.22E-09
5.20E-10
3.16E-10 -2.72E-10 -4.50E-10 -9.98E-10 -1.57E-09 -2.34E-09 -1.75E-09
2.54E-09 2.85E-09 3.24E-09 3.33E-09 3.32E-09 3.45E-09 2.69E-09
7.28E-09 7.53E-09 8.44E-09 8.14E-09 7.54E-09 7.11E-09 5.62E-09
-6.65E-09 -8.07E-09 -9.34E-09 -1.01E-08 -1.07E-08 -1.18E-08 -9.13E-09
1.46E-10
1.65E-09
4.66E-09
-4.37E-09
-6.50E-08
PASS
6.50E-08
PASS
-1.30E-10
1.53E-09
4.07E-09
-4.33E-09
-6.50E-08
PASS
6.50E-08
PASS
-3.00E-10
1.79E-09
4.60E-09
-5.20E-09
-6.50E-08
PASS
6.50E-08
PASS
-1.62E-10
1.61E-09
4.26E-09
-4.59E-09
-6.50E-08
PASS
6.50E-08
PASS
-2.52E-10
2.22E-09
5.84E-09
-6.35E-09
-6.50E-08
PASS
6.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
232
-1.13E-09
2.04E-09
4.47E-09
-6.74E-09
-6.50E-08
PASS
6.50E-08
PASS
-6.46E-10
1.97E-09
4.76E-09
-6.05E-09
-6.50E-08
PASS
6.50E-08
PASS
Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-08
6.00E-08
4.00E-08
2.00E-08
0.00E+00
-2.00E-08
-4.00E-08
-6.00E-08
-8.00E-08
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.111. Plot of Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
233
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.111. Raw data for Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current4 3 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
10
4.73E-09 2.83E-09
4.55E-09 3.34E-09
3.99E-09 1.70E-09
1.15E-08 1.01E-08
7.50E-10 -7.10E-10
7.39E-09 6.22E-09
2.69E-09 1.66E-09
5.46E-09 4.37E-09
9.14E-09 7.97E-09
-1.70E-10 -1.23E-09
5.95E-09 4.83E-09
-9.40E-10 -3.33E-09
Total Dose (krad(Si))
20
30
1.70E-09 3.40E-10
1.54E-09 3.90E-10
2.80E-10 -8.50E-10
8.22E-09 7.45E-09
-2.06E-09 -4.13E-09
5.05E-09 4.49E-09
4.20E-10 5.30E-10
3.47E-09 2.62E-09
7.10E-09 6.52E-09
-2.67E-09 -3.54E-09
3.44E-09 2.61E-09
-4.36E-09 -5.04E-09
50
-1.56E-09
-8.90E-10
-1.84E-09
6.40E-09
-5.63E-09
3.93E-09
-9.30E-10
2.10E-09
5.33E-09
-3.18E-09
2.01E-09
-5.68E-09
24 Hr
Anneal
60
-2.08E-09
-1.85E-09
-2.01E-09
6.26E-09
-6.56E-09
3.00E-09
-1.81E-09
1.01E-09
4.88E-09
-4.08E-09
1.89E-09
-5.80E-09
168 Hr
Anneal
70
-4.50E-10
-1.33E-09
-2.21E-09
6.65E-09
-4.48E-09
3.38E-09
-2.30E-10
1.86E-09
5.86E-09
-3.08E-09
1.79E-09
-5.77E-09
5.11E-09 3.45E-09 1.94E-09 6.40E-10 -7.04E-10 -1.25E-09 -3.64E-10
3.94E-09 4.03E-09 3.82E-09 4.23E-09 4.38E-09 4.64E-09 4.20E-09
1.59E-08 1.45E-08 1.24E-08 1.22E-08 1.13E-08 1.15E-08 1.11E-08
-5.69E-09 -7.61E-09 -8.54E-09 -1.10E-08 -1.27E-08 -1.40E-08 -1.19E-08
4.90E-09
3.71E-09
1.51E-08
-5.27E-09
-6.50E-08
PASS
6.50E-08
PASS
3.80E-09
3.66E-09
1.38E-08
-6.23E-09
-6.50E-08
PASS
6.50E-08
PASS
2.67E-09
3.86E-09
1.33E-08
-7.90E-09
-6.50E-08
PASS
6.50E-08
PASS
2.12E-09
3.87E-09
1.27E-08
-8.48E-09
-6.50E-08
PASS
6.50E-08
PASS
1.45E-09
3.49E-09
1.10E-08
-8.12E-09
-6.50E-08
PASS
6.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
234
6.00E-10
3.60E-09
1.05E-08
-9.28E-09
-6.50E-08
PASS
6.50E-08
PASS
1.56E-09
3.41E-09
1.09E-08
-7.80E-09
-6.50E-08
PASS
6.50E-08
PASS
Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-08
6.00E-08
4.00E-08
2.00E-08
0.00E+00
-2.00E-08
-4.00E-08
-6.00E-08
-8.00E-08
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.112. Plot of Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
235
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.112. Raw data for Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current4 4 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
2.12E-09
-1.00E-09
1.42E-08
7.32E-09
-2.74E-09
4.05E-09
7.65E-09
7.90E-10
1.02E-08
2.44E-09
3.78E-09
-1.65E-09
10
-1.99E-09
-4.87E-09
1.00E-08
3.42E-09
-4.97E-09
8.70E-10
4.31E-09
-2.28E-09
7.08E-09
-4.40E-10
8.50E-10
-5.97E-09
Total Dose (krad(Si))
20
30
-3.40E-09 -4.58E-09
-7.08E-09 -7.34E-09
6.98E-09 6.03E-09
1.16E-09 2.10E-10
-6.57E-09 -7.50E-09
-5.00E-10 -5.20E-10
3.14E-09 2.73E-09
-3.66E-09 -4.53E-09
6.28E-09 6.05E-09
-1.79E-09 -1.97E-09
-5.70E-10 -1.25E-09
-6.95E-09 -7.47E-09
50
-5.16E-09
-8.75E-09
4.88E-09
-1.07E-09
-8.09E-09
-1.01E-09
2.57E-09
-3.73E-09
5.41E-09
-2.70E-09
-1.73E-09
-8.06E-09
24 Hr
Anneal
60
-5.89E-09
-1.02E-08
4.26E-09
-1.56E-09
-9.08E-09
-1.67E-09
1.36E-09
-4.75E-09
4.14E-09
-3.73E-09
-1.89E-09
-8.23E-09
168 Hr
Anneal
70
-5.05E-09
-8.85E-09
5.46E-09
-7.20E-10
-9.07E-09
-9.50E-10
2.25E-09
-4.74E-09
5.62E-09
-3.26E-09
-2.12E-09
-8.19E-09
3.98E-09 3.26E-10 -1.78E-09 -2.64E-09 -3.64E-09 -4.50E-09 -3.65E-09
6.87E-09 6.41E-09 5.90E-09 5.76E-09 5.64E-09 5.94E-09 6.12E-09
2.28E-08 1.79E-08 1.44E-08 1.32E-08 1.18E-08 1.18E-08 1.31E-08
-1.49E-08 -1.72E-08 -1.79E-08 -1.84E-08 -1.91E-08 -2.08E-08 -2.04E-08
5.02E-09
3.84E-09
1.56E-08
-5.51E-09
-6.50E-08
PASS
6.50E-08
PASS
1.91E-09
3.76E-09
1.22E-08
-8.41E-09
-6.50E-08
PASS
6.50E-08
PASS
6.94E-10
3.99E-09
1.16E-08
-1.03E-08
-6.50E-08
PASS
6.50E-08
PASS
3.52E-10
4.13E-09
1.17E-08
-1.10E-08
-6.50E-08
PASS
6.50E-08
PASS
1.08E-10
3.81E-09
1.06E-08
-1.03E-08
-6.50E-08
PASS
6.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
236
-9.30E-10
3.67E-09
9.14E-09
-1.10E-08
-6.50E-08
PASS
6.50E-08
PASS
-2.16E-10
4.20E-09
1.13E-08
-1.17E-08
-6.50E-08
PASS
6.50E-08
PASS
+Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.113. Plot of +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
237
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.113. Raw data for +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS4 1 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.51E-07
-3.72E-07
-3.78E-07
-3.88E-07
-3.76E-07
-3.84E-07
-3.72E-07
-3.66E-07
-3.72E-07
-3.71E-07
-3.55E-07
-3.63E-07
10
-3.62E-07
-3.86E-07
-3.92E-07
-4.01E-07
-3.90E-07
-3.87E-07
-3.74E-07
-3.71E-07
-3.76E-07
-3.74E-07
-3.52E-07
-3.64E-07
Total Dose (krad(Si))
20
30
-3.68E-07 -3.74E-07
-3.93E-07 -3.97E-07
-4.01E-07 -4.04E-07
-4.13E-07 -4.16E-07
-4.01E-07 -4.05E-07
-3.93E-07 -4.01E-07
-3.83E-07 -3.89E-07
-3.78E-07 -3.86E-07
-3.83E-07 -3.89E-07
-3.81E-07 -3.88E-07
-3.53E-07 -3.55E-07
-3.62E-07 -3.63E-07
50
-3.91E-07
-4.13E-07
-4.20E-07
-4.30E-07
-4.20E-07
-4.17E-07
-4.07E-07
-4.04E-07
-4.06E-07
-4.04E-07
-3.57E-07
-3.62E-07
24 Hr
Anneal
60
-3.90E-07
-4.15E-07
-4.21E-07
-4.30E-07
-4.19E-07
-4.15E-07
-4.07E-07
-4.02E-07
-4.05E-07
-4.06E-07
-3.58E-07
-3.65E-07
168 Hr
Anneal
70
-3.75E-07
-3.95E-07
-4.03E-07
-4.12E-07
-4.03E-07
-4.03E-07
-3.91E-07
-3.86E-07
-3.90E-07
-3.89E-07
-3.58E-07
-3.67E-07
-3.73E-07 -3.86E-07 -3.95E-07 -3.99E-07 -4.15E-07 -4.15E-07 -3.98E-07
1.36E-08 1.48E-08 1.69E-08 1.54E-08 1.48E-08 1.53E-08 1.40E-08
-3.36E-07 -3.45E-07 -3.49E-07 -3.57E-07 -3.74E-07 -3.73E-07 -3.59E-07
-4.10E-07 -4.27E-07 -4.42E-07 -4.42E-07 -4.55E-07 -4.57E-07 -4.36E-07
-3.73E-07
6.62E-09
-3.55E-07
-3.91E-07
-6.50E-07
PASS
6.50E-07
PASS
-3.76E-07
6.38E-09
-3.59E-07
-3.94E-07
-7.00E-07
PASS
7.00E-07
PASS
-3.84E-07
5.62E-09
-3.68E-07
-3.99E-07
-7.50E-07
PASS
7.50E-07
PASS
-3.91E-07
5.78E-09
-3.75E-07
-4.06E-07
-7.50E-07
PASS
7.50E-07
PASS
-4.08E-07
5.24E-09
-3.93E-07
-4.22E-07
-8.00E-07
PASS
8.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
238
-4.07E-07
4.82E-09
-3.94E-07
-4.20E-07
-8.00E-07
PASS
8.00E-07
PASS
-3.92E-07
6.22E-09
-3.75E-07
-4.09E-07
-8.00E-07
PASS
8.00E-07
PASS
+Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.114. Plot of +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
239
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.114. Raw data for +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS4 2 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.44E-07
-3.92E-07
-3.77E-07
-3.74E-07
-3.61E-07
-3.77E-07
-3.71E-07
-3.64E-07
-3.64E-07
-3.68E-07
-3.74E-07
-3.73E-07
10
-3.54E-07
-4.03E-07
-3.90E-07
-3.87E-07
-3.75E-07
-3.80E-07
-3.75E-07
-3.67E-07
-3.66E-07
-3.70E-07
-3.73E-07
-3.75E-07
Total Dose (krad(Si))
20
30
-3.62E-07 -3.68E-07
-4.11E-07 -4.17E-07
-4.00E-07 -4.03E-07
-3.96E-07 -4.01E-07
-3.84E-07 -3.90E-07
-3.87E-07 -3.94E-07
-3.83E-07 -3.90E-07
-3.74E-07 -3.81E-07
-3.73E-07 -3.79E-07
-3.78E-07 -3.84E-07
-3.72E-07 -3.74E-07
-3.72E-07 -3.72E-07
50
-3.86E-07
-4.31E-07
-4.18E-07
-4.15E-07
-4.05E-07
-4.12E-07
-4.08E-07
-4.01E-07
-3.96E-07
-4.04E-07
-3.76E-07
-3.71E-07
24 Hr
Anneal
60
-3.85E-07
-4.32E-07
-4.21E-07
-4.16E-07
-4.05E-07
-4.10E-07
-4.07E-07
-4.00E-07
-3.95E-07
-4.05E-07
-3.79E-07
-3.75E-07
168 Hr
Anneal
70
-3.70E-07
-4.13E-07
-4.00E-07
-3.97E-07
-3.87E-07
-3.95E-07
-3.89E-07
-3.83E-07
-3.81E-07
-3.86E-07
-3.78E-07
-3.76E-07
-3.69E-07 -3.82E-07 -3.91E-07 -3.96E-07 -4.11E-07 -4.12E-07 -3.93E-07
1.81E-08 1.83E-08 1.89E-08 1.83E-08 1.68E-08 1.79E-08 1.63E-08
-3.20E-07 -3.32E-07 -3.39E-07 -3.46E-07 -3.65E-07 -3.63E-07 -3.49E-07
-4.19E-07 -4.32E-07 -4.42E-07 -4.46E-07 -4.57E-07 -4.61E-07 -4.38E-07
-3.69E-07
5.51E-09
-3.54E-07
-3.84E-07
-6.50E-07
PASS
6.50E-07
PASS
-3.72E-07
5.68E-09
-3.56E-07
-3.87E-07
-7.00E-07
PASS
7.00E-07
PASS
-3.79E-07
5.91E-09
-3.63E-07
-3.95E-07
-7.50E-07
PASS
7.50E-07
PASS
-3.86E-07
6.28E-09
-3.68E-07
-4.03E-07
-7.50E-07
PASS
7.50E-07
PASS
-4.04E-07
5.97E-09
-3.88E-07
-4.21E-07
-8.00E-07
PASS
8.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
240
-4.03E-07
5.74E-09
-3.88E-07
-4.19E-07
-8.00E-07
PASS
8.00E-07
PASS
-3.87E-07
5.62E-09
-3.71E-07
-4.02E-07
-8.00E-07
PASS
8.00E-07
PASS
+Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.115. Plot of +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
241
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.115. Raw data for +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS4 3 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.45E-07
-3.85E-07
-3.79E-07
-3.70E-07
-3.62E-07
-3.75E-07
-3.71E-07
-3.64E-07
-3.56E-07
-3.68E-07
-3.76E-07
-3.84E-07
10
-3.54E-07
-3.96E-07
-3.92E-07
-3.81E-07
-3.73E-07
-3.76E-07
-3.72E-07
-3.66E-07
-3.59E-07
-3.70E-07
-3.72E-07
-3.83E-07
Total Dose (krad(Si))
20
30
-3.60E-07 -3.67E-07
-4.04E-07 -4.09E-07
-4.01E-07 -4.06E-07
-3.92E-07 -3.97E-07
-3.85E-07 -3.89E-07
-3.84E-07 -3.90E-07
-3.80E-07 -3.87E-07
-3.72E-07 -3.80E-07
-3.65E-07 -3.71E-07
-3.77E-07 -3.84E-07
-3.73E-07 -3.74E-07
-3.81E-07 -3.82E-07
50
-3.83E-07
-4.23E-07
-4.22E-07
-4.11E-07
-4.04E-07
-4.09E-07
-4.03E-07
-3.97E-07
-3.90E-07
-4.01E-07
-3.77E-07
-3.81E-07
24 Hr
Anneal
60
-3.83E-07
-4.26E-07
-4.22E-07
-4.11E-07
-4.04E-07
-4.08E-07
-4.04E-07
-3.97E-07
-3.89E-07
-4.02E-07
-3.79E-07
-3.84E-07
168 Hr
Anneal
70
-3.68E-07
-4.06E-07
-4.03E-07
-3.93E-07
-3.86E-07
-3.94E-07
-3.87E-07
-3.82E-07
-3.73E-07
-3.86E-07
-3.78E-07
-3.86E-07
-3.68E-07 -3.79E-07 -3.88E-07 -3.94E-07 -4.09E-07 -4.09E-07 -3.91E-07
1.58E-08 1.68E-08 1.76E-08 1.69E-08 1.64E-08 1.72E-08 1.53E-08
-3.25E-07 -3.33E-07 -3.40E-07 -3.47E-07 -3.64E-07 -3.62E-07 -3.50E-07
-4.12E-07 -4.25E-07 -4.37E-07 -4.40E-07 -4.53E-07 -4.56E-07 -4.33E-07
-3.67E-07
7.15E-09
-3.47E-07
-3.86E-07
-6.50E-07
PASS
6.50E-07
PASS
-3.69E-07
6.78E-09
-3.50E-07
-3.87E-07
-7.00E-07
PASS
7.00E-07
PASS
-3.76E-07
7.13E-09
-3.56E-07
-3.95E-07
-7.50E-07
PASS
7.50E-07
PASS
-3.82E-07
7.38E-09
-3.62E-07
-4.03E-07
-7.50E-07
PASS
7.50E-07
PASS
-4.00E-07
7.14E-09
-3.80E-07
-4.20E-07
-8.00E-07
PASS
8.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
242
-4.00E-07
7.34E-09
-3.80E-07
-4.20E-07
-8.00E-07
PASS
8.00E-07
PASS
-3.84E-07
7.74E-09
-3.63E-07
-4.06E-07
-8.00E-07
PASS
8.00E-07
PASS
+Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.116. Plot of +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
243
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.116. Raw data for +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS4 4 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.56E-07
-3.74E-07
-3.71E-07
-3.89E-07
-3.81E-07
-3.81E-07
-3.70E-07
-3.73E-07
-3.78E-07
-3.75E-07
-3.50E-07
-3.65E-07
10
-3.66E-07
-3.86E-07
-3.85E-07
-4.02E-07
-3.93E-07
-3.83E-07
-3.72E-07
-3.76E-07
-3.80E-07
-3.78E-07
-3.46E-07
-3.66E-07
Total Dose (krad(Si))
20
30
-3.72E-07 -3.80E-07
-3.96E-07 -4.00E-07
-3.96E-07 -4.00E-07
-4.12E-07 -4.16E-07
-4.04E-07 -4.09E-07
-3.90E-07 -3.96E-07
-3.82E-07 -3.89E-07
-3.84E-07 -3.93E-07
-3.89E-07 -3.93E-07
-3.84E-07 -3.90E-07
-3.47E-07 -3.49E-07
-3.62E-07 -3.64E-07
50
-3.98E-07
-4.15E-07
-4.13E-07
-4.30E-07
-4.25E-07
-4.13E-07
-4.07E-07
-4.12E-07
-4.10E-07
-4.08E-07
-3.51E-07
-3.64E-07
24 Hr
Anneal
60
-3.98E-07
-4.18E-07
-4.15E-07
-4.32E-07
-4.22E-07
-4.11E-07
-4.05E-07
-4.11E-07
-4.09E-07
-4.10E-07
-3.53E-07
-3.66E-07
168 Hr
Anneal
70
-3.81E-07
-3.98E-07
-3.96E-07
-4.13E-07
-4.05E-07
-3.98E-07
-3.89E-07
-3.95E-07
-3.94E-07
-3.93E-07
-3.51E-07
-3.67E-07
-3.74E-07 -3.86E-07 -3.96E-07 -4.01E-07 -4.16E-07 -4.17E-07 -3.98E-07
1.21E-08 1.29E-08 1.48E-08 1.35E-08 1.24E-08 1.24E-08 1.19E-08
-3.41E-07 -3.51E-07 -3.55E-07 -3.64E-07 -3.82E-07 -3.83E-07 -3.66E-07
-4.07E-07 -4.22E-07 -4.36E-07 -4.38E-07 -4.50E-07 -4.51E-07 -4.31E-07
-3.75E-07
4.09E-09
-3.64E-07
-3.87E-07
-6.50E-07
PASS
6.50E-07
PASS
-3.78E-07
3.96E-09
-3.67E-07
-3.89E-07
-7.00E-07
PASS
7.00E-07
PASS
-3.86E-07
3.63E-09
-3.76E-07
-3.96E-07
-7.50E-07
PASS
7.50E-07
PASS
-3.92E-07
2.69E-09
-3.85E-07
-3.99E-07
-7.50E-07
PASS
7.50E-07
PASS
-4.10E-07
2.63E-09
-4.03E-07
-4.17E-07
-8.00E-07
PASS
8.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
244
-4.09E-07
2.54E-09
-4.02E-07
-4.16E-07
-8.00E-07
PASS
8.00E-07
PASS
-3.94E-07
3.11E-09
-3.85E-07
-4.02E-07
-8.00E-07
PASS
8.00E-07
PASS
-Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.117. Plot of -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
245
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.117. Raw data for -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS4 1 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.57E-07
-3.70E-07
-3.78E-07
-3.97E-07
-3.81E-07
-3.85E-07
-3.69E-07
-3.72E-07
-3.72E-07
-3.80E-07
-3.50E-07
-3.66E-07
10
-3.65E-07
-3.82E-07
-3.93E-07
-4.09E-07
-3.93E-07
-3.87E-07
-3.70E-07
-3.74E-07
-3.76E-07
-3.82E-07
-3.46E-07
-3.66E-07
Total Dose (krad(Si))
20
30
-3.71E-07 -3.78E-07
-3.90E-07 -3.94E-07
-4.01E-07 -4.04E-07
-4.18E-07 -4.22E-07
-4.03E-07 -4.07E-07
-3.95E-07 -4.03E-07
-3.77E-07 -3.85E-07
-3.80E-07 -3.88E-07
-3.82E-07 -3.88E-07
-3.89E-07 -3.94E-07
-3.45E-07 -3.48E-07
-3.63E-07 -3.64E-07
50
-3.91E-07
-4.08E-07
-4.20E-07
-4.35E-07
-4.20E-07
-4.19E-07
-4.04E-07
-4.08E-07
-4.06E-07
-4.12E-07
-3.50E-07
-3.63E-07
24 Hr
Anneal
60
-3.91E-07
-4.08E-07
-4.18E-07
-4.35E-07
-4.20E-07
-4.16E-07
-4.01E-07
-4.05E-07
-4.03E-07
-4.11E-07
-3.51E-07
-3.65E-07
168 Hr
Anneal
70
-3.77E-07
-3.92E-07
-4.02E-07
-4.18E-07
-4.02E-07
-4.02E-07
-3.88E-07
-3.90E-07
-3.90E-07
-3.96E-07
-3.49E-07
-3.67E-07
-3.77E-07 -3.88E-07 -3.96E-07 -4.01E-07 -4.15E-07 -4.15E-07 -3.98E-07
1.47E-08 1.61E-08 1.72E-08 1.63E-08 1.62E-08 1.62E-08 1.50E-08
-3.36E-07 -3.44E-07 -3.49E-07 -3.56E-07 -3.70E-07 -3.70E-07 -3.57E-07
-4.17E-07 -4.33E-07 -4.44E-07 -4.46E-07 -4.59E-07 -4.59E-07 -4.39E-07
-3.75E-07
6.68E-09
-3.57E-07
-3.94E-07
-6.50E-07
PASS
6.50E-07
PASS
-3.78E-07
6.91E-09
-3.59E-07
-3.97E-07
-7.00E-07
PASS
7.00E-07
PASS
-3.85E-07
7.14E-09
-3.65E-07
-4.04E-07
-7.50E-07
PASS
7.50E-07
PASS
-3.91E-07
7.04E-09
-3.72E-07
-4.11E-07
-7.50E-07
PASS
7.50E-07
PASS
-4.10E-07
5.98E-09
-3.93E-07
-4.26E-07
-8.00E-07
PASS
8.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
246
-4.07E-07
6.23E-09
-3.90E-07
-4.24E-07
-8.00E-07
PASS
8.00E-07
PASS
-3.93E-07
5.96E-09
-3.77E-07
-4.10E-07
-8.00E-07
PASS
8.00E-07
PASS
-Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.118. Plot of -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
247
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.118. Raw data for -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS4 2 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.50E-07
-3.92E-07
-3.76E-07
-3.75E-07
-3.66E-07
-3.76E-07
-3.72E-07
-3.67E-07
-3.66E-07
-3.67E-07
-3.81E-07
-3.77E-07
10
-3.59E-07
-4.03E-07
-3.89E-07
-3.87E-07
-3.78E-07
-3.79E-07
-3.75E-07
-3.71E-07
-3.69E-07
-3.70E-07
-3.77E-07
-3.76E-07
Total Dose (krad(Si))
20
30
-3.65E-07 -3.72E-07
-4.10E-07 -4.14E-07
-3.97E-07 -4.00E-07
-3.98E-07 -4.00E-07
-3.89E-07 -3.93E-07
-3.87E-07 -3.93E-07
-3.83E-07 -3.90E-07
-3.77E-07 -3.84E-07
-3.76E-07 -3.81E-07
-3.76E-07 -3.84E-07
-3.78E-07 -3.78E-07
-3.74E-07 -3.75E-07
50
-3.87E-07
-4.28E-07
-4.14E-07
-4.14E-07
-4.09E-07
-4.11E-07
-4.08E-07
-4.06E-07
-3.99E-07
-4.05E-07
-3.77E-07
-3.74E-07
24 Hr
Anneal
60
-3.88E-07
-4.28E-07
-4.14E-07
-4.15E-07
-4.07E-07
-4.08E-07
-4.06E-07
-4.04E-07
-3.97E-07
-4.03E-07
-3.81E-07
-3.77E-07
168 Hr
Anneal
70
-3.71E-07
-4.11E-07
-3.98E-07
-3.96E-07
-3.90E-07
-3.95E-07
-3.91E-07
-3.87E-07
-3.84E-07
-3.86E-07
-3.80E-07
-3.78E-07
-3.72E-07 -3.83E-07 -3.92E-07 -3.96E-07 -4.10E-07 -4.11E-07 -3.93E-07
1.55E-08 1.63E-08 1.66E-08 1.56E-08 1.49E-08 1.49E-08 1.47E-08
-3.30E-07 -3.39E-07 -3.46E-07 -3.53E-07 -3.70E-07 -3.70E-07 -3.53E-07
-4.14E-07 -4.28E-07 -4.37E-07 -4.39E-07 -4.51E-07 -4.51E-07 -4.34E-07
-3.69E-07
4.17E-09
-3.58E-07
-3.81E-07
-6.50E-07
PASS
6.50E-07
PASS
-3.73E-07
4.30E-09
-3.61E-07
-3.85E-07
-7.00E-07
PASS
7.00E-07
PASS
-3.80E-07
4.90E-09
-3.66E-07
-3.93E-07
-7.50E-07
PASS
7.50E-07
PASS
-3.86E-07
5.00E-09
-3.73E-07
-4.00E-07
-7.50E-07
PASS
7.50E-07
PASS
-4.05E-07
4.40E-09
-3.93E-07
-4.18E-07
-8.00E-07
PASS
8.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
248
-4.04E-07
4.30E-09
-3.92E-07
-4.15E-07
-8.00E-07
PASS
8.00E-07
PASS
-3.89E-07
4.51E-09
-3.76E-07
-4.01E-07
-8.00E-07
PASS
8.00E-07
PASS
-Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.119. Plot of -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
249
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.119. Raw data for -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS4 3 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.47E-07
-3.88E-07
-3.79E-07
-3.78E-07
-3.61E-07
-3.80E-07
-3.71E-07
-3.65E-07
-3.64E-07
-3.66E-07
-3.80E-07
-3.81E-07
10
-3.56E-07
-4.01E-07
-3.95E-07
-3.92E-07
-3.72E-07
-3.83E-07
-3.73E-07
-3.70E-07
-3.67E-07
-3.68E-07
-3.77E-07
-3.80E-07
Total Dose (krad(Si))
20
30
-3.62E-07 -3.68E-07
-4.07E-07 -4.11E-07
-4.01E-07 -4.05E-07
-4.00E-07 -4.04E-07
-3.82E-07 -3.85E-07
-3.89E-07 -3.97E-07
-3.81E-07 -3.88E-07
-3.74E-07 -3.82E-07
-3.73E-07 -3.79E-07
-3.75E-07 -3.80E-07
-3.77E-07 -3.77E-07
-3.76E-07 -3.77E-07
50
-3.83E-07
-4.25E-07
-4.19E-07
-4.18E-07
-4.00E-07
-4.14E-07
-4.03E-07
-3.99E-07
-3.96E-07
-4.00E-07
-3.79E-07
-3.76E-07
24 Hr
Anneal
60
-3.82E-07
-4.25E-07
-4.20E-07
-4.19E-07
-3.98E-07
-4.12E-07
-4.03E-07
-3.98E-07
-3.94E-07
-3.98E-07
-3.80E-07
-3.80E-07
168 Hr
Anneal
70
-3.68E-07
-4.07E-07
-4.03E-07
-4.00E-07
-3.83E-07
-3.99E-07
-3.89E-07
-3.84E-07
-3.80E-07
-3.85E-07
-3.80E-07
-3.81E-07
-3.70E-07 -3.83E-07 -3.90E-07 -3.95E-07 -4.09E-07 -4.09E-07 -3.92E-07
1.63E-08 1.88E-08 1.84E-08 1.79E-08 1.74E-08 1.82E-08 1.63E-08
-3.26E-07 -3.31E-07 -3.40E-07 -3.46E-07 -3.61E-07 -3.59E-07 -3.48E-07
-4.15E-07 -4.35E-07 -4.41E-07 -4.44E-07 -4.57E-07 -4.59E-07 -4.37E-07
-3.69E-07
6.64E-09
-3.51E-07
-3.88E-07
-6.50E-07
PASS
6.50E-07
PASS
-3.72E-07
6.32E-09
-3.55E-07
-3.89E-07
-7.00E-07
PASS
7.00E-07
PASS
-3.78E-07
6.49E-09
-3.61E-07
-3.96E-07
-7.50E-07
PASS
7.50E-07
PASS
-3.85E-07
7.41E-09
-3.65E-07
-4.06E-07
-7.50E-07
PASS
7.50E-07
PASS
-4.02E-07
6.93E-09
-3.83E-07
-4.21E-07
-8.00E-07
PASS
8.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
250
-4.01E-07
6.71E-09
-3.83E-07
-4.19E-07
-8.00E-07
PASS
8.00E-07
PASS
-3.87E-07
7.36E-09
-3.67E-07
-4.08E-07
-8.00E-07
PASS
8.00E-07
PASS
-Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.120. Plot of -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
251
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.120. Raw data for -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS4 4 5V (A)
@ VS=+5V, VCM=0V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-3.55E-07
-3.69E-07
-3.81E-07
-3.92E-07
-3.75E-07
-3.81E-07
-3.74E-07
-3.71E-07
-3.84E-07
-3.74E-07
-3.50E-07
-3.59E-07
10
-3.64E-07
-3.81E-07
-3.95E-07
-4.04E-07
-3.88E-07
-3.84E-07
-3.76E-07
-3.75E-07
-3.88E-07
-3.78E-07
-3.48E-07
-3.59E-07
Total Dose (krad(Si))
20
30
-3.71E-07 -3.76E-07
-3.89E-07 -3.95E-07
-4.02E-07 -4.06E-07
-4.12E-07 -4.15E-07
-3.98E-07 -4.02E-07
-3.90E-07 -3.96E-07
-3.84E-07 -3.92E-07
-3.80E-07 -3.88E-07
-3.93E-07 -3.99E-07
-3.82E-07 -3.90E-07
-3.47E-07 -3.48E-07
-3.55E-07 -3.58E-07
50
-3.93E-07
-4.08E-07
-4.18E-07
-4.30E-07
-4.16E-07
-4.13E-07
-4.12E-07
-4.09E-07
-4.16E-07
-4.08E-07
-3.50E-07
-3.56E-07
24 Hr
Anneal
60
-3.93E-07
-4.08E-07
-4.21E-07
-4.31E-07
-4.16E-07
-4.10E-07
-4.07E-07
-4.08E-07
-4.15E-07
-4.08E-07
-3.51E-07
-3.58E-07
168 Hr
Anneal
70
-3.76E-07
-3.89E-07
-4.02E-07
-4.14E-07
-3.98E-07
-3.97E-07
-3.92E-07
-3.91E-07
-4.00E-07
-3.92E-07
-3.50E-07
-3.61E-07
-3.74E-07 -3.87E-07 -3.94E-07 -3.99E-07 -4.13E-07 -4.14E-07 -3.96E-07
1.36E-08 1.51E-08 1.57E-08 1.45E-08 1.38E-08 1.43E-08 1.42E-08
-3.37E-07 -3.45E-07 -3.51E-07 -3.59E-07 -3.75E-07 -3.74E-07 -3.57E-07
-4.11E-07 -4.28E-07 -4.37E-07 -4.39E-07 -4.51E-07 -4.53E-07 -4.35E-07
-3.77E-07
5.37E-09
-3.62E-07
-3.91E-07
-6.50E-07
PASS
6.50E-07
PASS
-3.80E-07
5.55E-09
-3.65E-07
-3.95E-07
-7.00E-07
PASS
7.00E-07
PASS
-3.86E-07
5.62E-09
-3.70E-07
-4.01E-07
-7.50E-07
PASS
7.50E-07
PASS
-3.93E-07
4.56E-09
-3.80E-07
-4.06E-07
-7.50E-07
PASS
7.50E-07
PASS
-4.11E-07
3.43E-09
-4.02E-07
-4.21E-07
-8.00E-07
PASS
8.00E-07
PASS
An ISO 9001:2008 and DSCC Certified Company
252
-4.09E-07
3.08E-09
-4.01E-07
-4.18E-07
-8.00E-07
PASS
8.00E-07
PASS
-3.94E-07
3.95E-09
-3.84E-07
-4.05E-07
-8.00E-07
PASS
8.00E-07
PASS
Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.121. Plot of Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
253
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.121. Raw data for Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage5 1 5V (V)
@ VS=+5V, VCM=5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
10
7.15E-05 6.07E-05
3.80E-05 3.27E-05
2.51E-04 2.42E-04
4.70E-05 3.51E-05
1.84E-04 1.78E-04
2.16E-04 2.07E-04
-9.73E-05 -1.01E-04
4.61E-04 4.53E-04
-1.30E-05 -1.79E-05
7.93E-05 7.29E-05
-1.49E-04 -1.47E-04
2.61E-04 2.62E-04
24 Hr
168 Hr
Total Dose (krad(Si))
Anneal
Anneal
60
70
20
30
50
5.76E-05 5.22E-05 4.15E-05 4.61E-05 4.79E-05
2.90E-05 2.73E-05 2.34E-05 2.57E-05 1.91E-05
2.42E-04 2.43E-04 2.39E-04 2.38E-04 2.38E-04
3.05E-05 3.06E-05 3.11E-05 3.19E-05 2.88E-05
1.77E-04 1.79E-04 1.76E-04 1.77E-04 1.73E-04
2.06E-04 2.06E-04 2.02E-04 2.03E-04 1.95E-04
-9.86E-05 -9.79E-05 -9.76E-05 -9.60E-05 -9.63E-05
4.53E-04 4.54E-04 4.52E-04 4.50E-04 4.41E-04
-1.64E-05 -1.69E-05 -1.69E-05 -1.66E-05 -2.24E-05
7.55E-05 7.42E-05 7.06E-05 7.18E-05 7.38E-05
-1.45E-04 -1.45E-04 -1.44E-04 -1.46E-04 -1.44E-04
2.67E-04 2.65E-04 2.63E-04 2.61E-04 2.64E-04
1.18E-04 1.10E-04 1.07E-04 1.06E-04 1.02E-04 1.04E-04 1.01E-04
9.43E-05 9.50E-05 9.67E-05 9.85E-05 9.87E-05 9.73E-05 9.83E-05
3.77E-04 3.70E-04 3.72E-04 3.76E-04 3.73E-04 3.70E-04 3.71E-04
-1.40E-04 -1.51E-04 -1.58E-04 -1.64E-04 -1.69E-04 -1.63E-04 -1.68E-04
1.29E-04
2.19E-04
7.30E-04
-4.71E-04
-8.00E-04
PASS
8.00E-04
PASS
1.23E-04
2.17E-04
7.18E-04
-4.73E-04
-9.50E-04
PASS
9.50E-04
PASS
1.24E-04
2.16E-04
7.16E-04
-4.68E-04
-9.50E-04
PASS
9.50E-04
PASS
1.24E-04
2.16E-04
7.17E-04
-4.69E-04
-9.50E-04
PASS
9.50E-04
PASS
1.22E-04
2.15E-04
7.12E-04
-4.68E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
254
1.22E-04
2.14E-04
7.10E-04
-4.65E-04
-9.50E-04
PASS
9.50E-04
PASS
1.18E-04
2.11E-04
6.97E-04
-4.60E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.122. Plot of Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
255
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.122. Raw data for Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage5 2 5V (V)
@ VS=+5V, VCM=5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
10
1.27E-04 1.17E-04
-8.36E-05 -8.95E-05
1.54E-04 1.47E-04
1.20E-04 1.13E-04
3.64E-04 3.59E-04
-2.36E-06 -8.76E-06
1.52E-04 1.49E-04
2.54E-04 2.41E-04
1.92E-04 1.88E-04
-4.63E-05 -4.99E-05
1.10E-04 1.11E-04
3.90E-04 3.91E-04
24 Hr
168 Hr
Total Dose (krad(Si))
Anneal
Anneal
60
70
20
30
50
1.15E-04 1.14E-04 1.11E-04 1.13E-04 1.11E-04
-8.98E-05 -9.41E-05 -9.39E-05 -8.90E-05 -9.19E-05
1.47E-04 1.48E-04 1.43E-04 1.48E-04 1.46E-04
1.11E-04 1.14E-04 1.09E-04 1.11E-04 1.17E-04
3.55E-04 3.55E-04 3.52E-04 3.55E-04 3.47E-04
-8.16E-06 -5.99E-06 -2.84E-06 -1.75E-06 -5.98E-06
1.48E-04 1.49E-04 1.51E-04 1.55E-04 1.42E-04
2.40E-04 2.38E-04 2.34E-04 2.37E-04 2.30E-04
1.92E-04 1.91E-04 1.95E-04 1.95E-04 1.88E-04
-4.69E-05 -4.79E-05 -4.93E-05 -4.33E-05 -4.55E-05
1.11E-04 1.14E-04 1.13E-04 1.15E-04 1.16E-04
3.93E-04 3.91E-04 3.95E-04 3.88E-04 3.93E-04
1.36E-04 1.29E-04 1.28E-04 1.27E-04 1.24E-04 1.27E-04 1.26E-04
1.59E-04 1.59E-04 1.58E-04 1.59E-04 1.58E-04 1.58E-04 1.56E-04
5.72E-04 5.65E-04 5.61E-04 5.64E-04 5.58E-04 5.59E-04 5.52E-04
-2.99E-04 -3.07E-04 -3.05E-04 -3.10E-04 -3.10E-04 -3.05E-04 -3.01E-04
1.10E-04
1.29E-04
4.62E-04
-2.43E-04
-8.00E-04
PASS
8.00E-04
PASS
1.04E-04
1.27E-04
4.52E-04
-2.44E-04
-9.50E-04
PASS
9.50E-04
PASS
1.05E-04
1.26E-04
4.51E-04
-2.41E-04
-9.50E-04
PASS
9.50E-04
PASS
1.05E-04
1.25E-04
4.48E-04
-2.38E-04
-9.50E-04
PASS
9.50E-04
PASS
1.06E-04
1.25E-04
4.48E-04
-2.37E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
256
1.08E-04
1.24E-04
4.48E-04
-2.31E-04
-9.50E-04
PASS
9.50E-04
PASS
1.02E-04
1.21E-04
4.34E-04
-2.31E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.123. Plot of Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
257
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.123. Raw data for Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage5 3 5V (V)
@ VS=+5V, VCM=5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
10
5.97E-04 5.87E-04
1.41E-04 1.34E-04
2.77E-04 2.72E-04
2.61E-04 2.55E-04
3.02E-05 2.54E-05
1.58E-04 1.52E-04
2.23E-04 2.16E-04
2.49E-04 2.45E-04
2.60E-04 2.57E-04
-3.79E-05 -4.06E-05
4.16E-04 4.20E-04
1.93E-04 1.99E-04
24 Hr
168 Hr
Total Dose (krad(Si))
Anneal
Anneal
60
70
20
30
50
5.83E-04 5.77E-04 5.73E-04 5.72E-04 5.69E-04
1.33E-04 1.27E-04 1.29E-04 1.33E-04 1.32E-04
2.66E-04 2.65E-04 2.61E-04 2.58E-04 2.49E-04
2.49E-04 2.43E-04 2.40E-04 2.39E-04 2.35E-04
2.12E-05 1.68E-05 1.64E-05 1.36E-05 1.45E-05
1.51E-04 1.51E-04 1.47E-04 1.47E-04 1.36E-04
2.18E-04 2.15E-04 2.10E-04 2.13E-04 2.17E-04
2.41E-04 2.39E-04 2.34E-04 2.36E-04 2.24E-04
2.57E-04 2.57E-04 2.52E-04 2.55E-04 2.58E-04
-4.18E-05 -4.34E-05 -4.50E-05 -4.16E-05 -3.86E-05
4.21E-04 4.22E-04 4.24E-04 4.22E-04 4.24E-04
1.95E-04 1.94E-04 1.99E-04 1.93E-04 1.96E-04
2.61E-04 2.55E-04 2.50E-04 2.46E-04 2.44E-04 2.43E-04 2.40E-04
2.13E-04 2.11E-04 2.10E-04 2.10E-04 2.08E-04 2.08E-04 2.07E-04
8.45E-04 8.33E-04 8.27E-04 8.23E-04 8.15E-04 8.14E-04 8.06E-04
-3.22E-04 -3.23E-04 -3.26E-04 -3.31E-04 -3.27E-04 -3.28E-04 -3.27E-04
1.70E-04
1.23E-04
5.08E-04
-1.67E-04
-8.00E-04
PASS
8.00E-04
PASS
1.66E-04
1.22E-04
5.01E-04
-1.69E-04
-9.50E-04
PASS
9.50E-04
PASS
1.65E-04
1.22E-04
5.01E-04
-1.71E-04
-9.50E-04
PASS
9.50E-04
PASS
1.64E-04
1.22E-04
4.99E-04
-1.72E-04
-9.50E-04
PASS
9.50E-04
PASS
1.60E-04
1.21E-04
4.92E-04
-1.72E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
258
1.62E-04
1.21E-04
4.93E-04
-1.69E-04
-9.50E-04
PASS
9.50E-04
PASS
1.59E-04
1.19E-04
4.86E-04
-1.68E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.50E-03
1.00E-03
5.00E-04
0.00E+00
-5.00E-04
-1.00E-03
-1.50E-03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.124. Plot of Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
259
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.124. Raw data for Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V versus total dose, including
the statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Voltage5 4 5V (V)
@ VS=+5V, VCM=5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
10
-1.77E-04 -1.86E-04
1.19E-04 1.10E-04
1.49E-04 1.41E-04
1.37E-04 1.30E-04
-1.61E-04 -1.69E-04
1.35E-04 1.26E-04
2.94E-04 2.87E-04
1.04E-04 9.72E-05
1.83E-04 1.76E-04
3.34E-05 2.69E-05
4.24E-04 4.27E-04
3.74E-05 4.41E-05
24 Hr
168 Hr
Total Dose (krad(Si))
Anneal
Anneal
60
70
20
30
50
-1.89E-04 -1.90E-04 -1.94E-04 -1.92E-04 -1.85E-04
1.09E-04 1.08E-04 1.05E-04 1.06E-04 1.10E-04
1.42E-04 1.40E-04 1.34E-04 1.35E-04 1.24E-04
1.30E-04 1.30E-04 1.29E-04 1.31E-04 1.25E-04
-1.70E-04 -1.74E-04 -1.69E-04 -1.68E-04 -1.80E-04
1.29E-04 1.31E-04 1.40E-04 1.37E-04 1.37E-04
2.91E-04 2.91E-04 2.91E-04 2.91E-04 2.81E-04
9.64E-05 9.92E-05 1.01E-04 1.01E-04 1.01E-04
1.79E-04 1.81E-04 1.85E-04 1.82E-04 1.79E-04
2.78E-05 2.96E-05 3.16E-05 3.30E-05 3.05E-05
4.27E-04 4.30E-04 4.27E-04 4.25E-04 4.28E-04
4.48E-05 4.48E-05 4.58E-05 4.35E-05 4.46E-05
1.35E-05 5.29E-06 4.37E-06 2.80E-06 1.05E-06 2.21E-06 -1.18E-06
1.67E-04 1.67E-04 1.68E-04 1.69E-04 1.67E-04 1.67E-04 1.66E-04
4.71E-04 4.63E-04 4.66E-04 4.67E-04 4.59E-04 4.60E-04 4.53E-04
-4.44E-04 -4.53E-04 -4.57E-04 -4.61E-04 -4.57E-04 -4.55E-04 -4.55E-04
1.50E-04
9.74E-05
4.17E-04
-1.17E-04
-8.00E-04
PASS
8.00E-04
PASS
1.43E-04
9.72E-05
4.09E-04
-1.24E-04
-9.50E-04
PASS
9.50E-04
PASS
1.45E-04
9.84E-05
4.14E-04
-1.25E-04
-9.50E-04
PASS
9.50E-04
PASS
1.46E-04
9.78E-05
4.14E-04
-1.22E-04
-9.50E-04
PASS
9.50E-04
PASS
1.50E-04
9.69E-05
4.15E-04
-1.16E-04
-9.50E-04
PASS
9.50E-04
PASS
An ISO 9001:2008 and DSCC Certified Company
260
1.49E-04
9.63E-05
4.13E-04
-1.15E-04
-9.50E-04
PASS
9.50E-04
PASS
1.46E-04
9.32E-05
4.01E-04
-1.10E-04
-9.50E-04
PASS
9.50E-04
PASS
Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-08
6.00E-08
4.00E-08
2.00E-08
0.00E+00
-2.00E-08
-4.00E-08
-6.00E-08
-8.00E-08
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.125. Plot of Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
261
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.125. Raw data for Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current5 1 5V (A)
@ VS=+5V, VCM=5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-9.15E-09
-3.30E-10
-2.76E-09
-1.57E-09
1.16E-08
-3.70E-10
1.11E-08
-4.60E-10
-1.05E-09
1.09E-08
9.00E-11
1.37E-09
10
-1.07E-08
-2.45E-09
-4.75E-09
-4.30E-09
8.75E-09
6.10E-10
1.30E-08
1.80E-09
-2.80E-10
1.18E-08
3.15E-09
6.51E-09
Total Dose (krad(Si))
20
30
-1.35E-08 -1.54E-08
-4.59E-09 -7.14E-09
-7.30E-09 -6.96E-09
-6.31E-09 -7.34E-09
7.21E-09 7.16E-09
1.12E-09 1.30E-09
1.41E-08 1.45E-08
2.49E-09 3.40E-09
6.60E-10 2.10E-09
1.22E-08 1.30E-08
4.75E-09 5.69E-09
7.58E-09 7.77E-09
50
-2.15E-08
-9.79E-09
-8.90E-09
-1.00E-08
3.72E-09
1.30E-09
1.60E-08
4.37E-09
2.93E-09
1.44E-08
6.04E-09
7.36E-09
24 Hr
Anneal
60
-1.88E-08
-8.09E-09
-7.30E-09
-7.51E-09
6.40E-09
3.45E-09
1.83E-08
5.26E-09
4.17E-09
1.51E-08
6.68E-09
7.40E-09
168 Hr
Anneal
70
-1.85E-08
-8.88E-09
-8.93E-09
-8.62E-09
5.00E-09
6.70E-10
1.37E-08
3.46E-09
8.90E-10
1.33E-08
7.76E-09
8.15E-09
-4.52E-10 -2.70E-09 -4.90E-09 -5.94E-09 -9.30E-09 -7.05E-09 -7.98E-09
7.52E-09 7.11E-09 7.56E-09 8.16E-09 8.93E-09 8.94E-09 8.37E-09
2.02E-08 1.68E-08 1.58E-08 1.64E-08 1.52E-08 1.75E-08 1.50E-08
-2.11E-08 -2.22E-08 -2.56E-08 -2.83E-08 -3.38E-08 -3.16E-08 -3.09E-08
4.03E-09
6.38E-09
2.15E-08
-1.35E-08
-6.50E-08
PASS
6.50E-08
PASS
5.38E-09
6.45E-09
2.31E-08
-1.23E-08
-6.50E-08
PASS
6.50E-08
PASS
6.11E-09
6.49E-09
2.39E-08
-1.17E-08
-6.50E-08
PASS
6.50E-08
PASS
6.85E-09
6.34E-09
2.42E-08
-1.05E-08
-6.50E-08
PASS
6.50E-08
PASS
7.80E-09
6.86E-09
2.66E-08
-1.10E-08
-6.50E-08
PASS
6.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
262
9.25E-09
6.91E-09
2.82E-08
-9.69E-09
-6.50E-08
PASS
6.50E-08
PASS
6.39E-09
6.56E-09
2.44E-08
-1.16E-08
-6.50E-08
PASS
6.50E-08
PASS
Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-08
6.00E-08
4.00E-08
2.00E-08
0.00E+00
-2.00E-08
-4.00E-08
-6.00E-08
-8.00E-08
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.126. Plot of Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
263
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.126. Raw data for Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current5 2 5V (A)
@ VS=+5V, VCM=5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
10
5.69E-09 4.59E-09
1.67E-09 9.60E-10
3.29E-09 1.87E-09
1.22E-08 9.36E-09
2.99E-09 1.60E-10
-2.01E-09 -1.12E-09
5.86E-09 6.84E-09
2.48E-09 4.36E-09
5.63E-09 6.97E-09
1.62E-08 1.72E-08
2.75E-09 5.23E-09
1.40E-08 1.99E-08
Total Dose (krad(Si))
20
30
2.79E-09 1.20E-09
-2.40E-10 -2.09E-09
2.40E-10 -4.80E-10
7.33E-09 6.98E-09
-2.55E-09 -3.36E-09
-7.20E-10 -9.20E-10
7.12E-09 8.05E-09
4.76E-09 5.23E-09
8.64E-09 9.07E-09
1.84E-08 1.81E-08
6.57E-09 7.52E-09
2.01E-08 2.01E-08
50
-1.26E-09
-3.88E-09
-2.45E-09
5.17E-09
-5.70E-09
1.10E-10
6.90E-09
4.67E-09
9.85E-09
1.82E-08
7.86E-09
2.02E-08
24 Hr
Anneal
60
-2.50E-10
-2.08E-09
-7.60E-10
7.12E-09
-2.63E-09
1.74E-09
8.66E-09
7.05E-09
1.17E-08
1.99E-08
8.53E-09
2.06E-08
168 Hr
Anneal
70
-6.90E-10
-4.04E-09
-1.75E-09
4.72E-09
-4.74E-09
-7.80E-10
7.01E-09
2.53E-09
8.23E-09
1.79E-08
9.68E-09
2.10E-08
5.16E-09 3.39E-09 1.51E-09 4.50E-10 -1.62E-09 2.80E-10 -1.30E-09
4.17E-09 3.73E-09 3.76E-09 4.03E-09 4.14E-09 3.94E-09 3.75E-09
1.66E-08 1.36E-08 1.18E-08 1.15E-08 9.74E-09 1.11E-08 8.97E-09
-6.28E-09 -6.85E-09 -8.81E-09 -1.06E-08 -1.30E-08 -1.05E-08 -1.16E-08
5.64E-09
6.72E-09
2.41E-08
-1.28E-08
-6.50E-08
PASS
6.50E-08
PASS
6.86E-09
6.66E-09
2.51E-08
-1.14E-08
-6.50E-08
PASS
6.50E-08
PASS
7.63E-09
6.97E-09
2.67E-08
-1.15E-08
-6.50E-08
PASS
6.50E-08
PASS
7.91E-09
6.91E-09
2.68E-08
-1.10E-08
-6.50E-08
PASS
6.50E-08
PASS
7.95E-09
6.75E-09
2.64E-08
-1.05E-08
-6.50E-08
PASS
6.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
264
9.80E-09
6.70E-09
2.82E-08
-8.56E-09
-6.50E-08
PASS
6.50E-08
PASS
6.98E-09
7.08E-09
2.64E-08
-1.24E-08
-6.50E-08
PASS
6.50E-08
PASS
Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-08
6.00E-08
4.00E-08
2.00E-08
0.00E+00
-2.00E-08
-4.00E-08
-6.00E-08
-8.00E-08
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.127. Plot of Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
265
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.127. Raw data for Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current5 3 5V (A)
@ VS=+5V, VCM=5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
5.43E-09
1.70E-10
-2.68E-09
-1.06E-09
8.07E-09
2.26E-09
4.30E-10
-1.33E-08
-2.80E-10
-6.72E-09
1.04E-08
4.70E-10
10
8.56E-09
2.10E-09
-1.96E-09
-1.11E-09
7.67E-09
6.43E-09
4.14E-09
-8.16E-09
3.49E-09
-2.75E-09
1.62E-08
1.02E-08
Total Dose (krad(Si))
20
30
5.69E-09 3.87E-09
1.72E-09 4.70E-10
-3.67E-09 -3.38E-09
-2.53E-09 -3.33E-09
5.45E-09 4.17E-09
7.88E-09 8.56E-09
5.37E-09 6.11E-09
-7.39E-09 -5.97E-09
4.23E-09 4.94E-09
-1.90E-09 -1.88E-09
1.77E-08 1.89E-08
1.09E-08 1.11E-08
50
1.46E-09
-7.10E-10
-5.97E-09
-5.69E-09
9.70E-10
8.72E-09
5.07E-09
-6.50E-09
5.01E-09
-2.80E-09
1.92E-08
1.06E-08
24 Hr
Anneal
60
3.19E-09
1.03E-09
-3.53E-09
-3.69E-09
3.76E-09
1.04E-08
6.59E-09
-4.57E-09
6.23E-09
-8.10E-10
2.01E-08
1.10E-08
168 Hr
Anneal
70
1.58E-09
-2.40E-09
-2.04E-09
-5.25E-09
2.81E-09
8.02E-09
5.12E-09
-8.82E-09
3.63E-09
-1.99E-09
2.10E-08
1.14E-08
1.99E-09 3.05E-09 1.33E-09 3.60E-10 -1.99E-09 1.52E-10 -1.06E-09
4.56E-09 4.87E-09 4.36E-09 3.69E-09 3.60E-09 3.58E-09 3.25E-09
1.45E-08 1.64E-08 1.33E-08 1.05E-08 7.88E-09 9.98E-09 7.85E-09
-1.05E-08 -1.03E-08 -1.06E-08 -9.76E-09 -1.19E-08 -9.67E-09 -9.97E-09
-3.52E-09
6.42E-09
1.41E-08
-2.11E-08
-6.50E-08
PASS
6.50E-08
PASS
6.30E-10
5.98E-09
1.70E-08
-1.58E-08
-6.50E-08
PASS
6.50E-08
PASS
1.64E-09
6.20E-09
1.86E-08
-1.54E-08
-6.50E-08
PASS
6.50E-08
PASS
2.35E-09
6.05E-09
1.89E-08
-1.42E-08
-6.50E-08
PASS
6.50E-08
PASS
1.90E-09
6.30E-09
1.92E-08
-1.54E-08
-6.50E-08
PASS
6.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
266
3.57E-09
6.09E-09
2.03E-08
-1.31E-08
-6.50E-08
PASS
6.50E-08
PASS
1.19E-09
6.68E-09
1.95E-08
-1.71E-08
-6.50E-08
PASS
6.50E-08
PASS
Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
8.00E-08
6.00E-08
4.00E-08
2.00E-08
0.00E+00
-2.00E-08
-4.00E-08
-6.00E-08
-8.00E-08
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.128. Plot of Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
267
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.128. Raw data for Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
Input Offset Current5 4 5V (A)
@ VS=+5V, VCM=5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Specification MAX
Status
0
-4.60E-09
-6.21E-09
-3.07E-09
-2.15E-09
-7.48E-09
3.20E-09
-1.11E-08
1.27E-08
-4.92E-09
-1.10E-10
-3.16E-09
-9.97E-09
10
-1.98E-09
-4.65E-09
-2.33E-09
-1.45E-09
-8.13E-09
7.33E-09
-6.24E-09
1.89E-08
0.00E+00
4.69E-09
3.14E-09
9.00E-10
Total Dose (krad(Si))
20
30
-3.14E-09 -4.19E-09
-5.14E-09 -6.69E-09
-3.67E-09 -4.56E-09
-2.98E-09 -3.60E-09
-9.67E-09 -9.73E-09
1.02E-08 1.10E-08
-4.33E-09 -2.88E-09
2.11E-08 2.23E-08
1.37E-09 2.04E-09
5.48E-09 6.23E-09
5.80E-09 7.34E-09
3.10E-09 3.37E-09
50
-8.36E-09
-8.88E-09
-6.63E-09
-4.77E-09
-1.19E-08
1.27E-08
-1.57E-09
2.50E-08
3.41E-09
7.03E-09
8.00E-09
3.95E-09
24 Hr
Anneal
60
-6.05E-09
-7.05E-09
-4.58E-09
-2.02E-09
-9.93E-09
1.38E-08
3.30E-10
2.74E-08
4.69E-09
9.09E-09
8.49E-09
3.90E-09
168 Hr
Anneal
70
-7.08E-09
-6.92E-09
-5.67E-09
-3.31E-09
-1.13E-08
1.05E-08
-3.15E-09
2.27E-08
2.01E-09
6.55E-09
9.80E-09
4.22E-09
-4.70E-09 -3.71E-09 -4.92E-09 -5.75E-09 -8.11E-09 -5.93E-09 -6.85E-09
2.19E-09 2.76E-09 2.79E-09 2.51E-09 2.67E-09 2.93E-09 2.90E-09
1.30E-09 3.85E-09 2.73E-09 1.13E-09 -7.91E-10 2.11E-09 1.10E-09
-1.07E-08 -1.13E-08 -1.26E-08 -1.26E-08 -1.54E-08 -1.40E-08 -1.48E-08
-4.00E-11
8.95E-09
2.45E-08
-2.46E-08
-6.50E-08
PASS
6.50E-08
PASS
4.94E-09
9.36E-09
3.06E-08
-2.07E-08
-6.50E-08
PASS
6.50E-08
PASS
6.75E-09
9.61E-09
3.31E-08
-1.96E-08
-6.50E-08
PASS
6.50E-08
PASS
7.74E-09
9.63E-09
3.41E-08
-1.87E-08
-6.50E-08
PASS
6.50E-08
PASS
9.31E-09
1.02E-08
3.72E-08
-1.86E-08
-6.50E-08
PASS
6.50E-08
PASS
An ISO 9001:2008 and DSCC Certified Company
268
1.11E-08
1.04E-08
3.96E-08
-1.75E-08
-6.50E-08
PASS
6.50E-08
PASS
7.73E-09
9.82E-09
3.46E-08
-1.92E-08
-6.50E-08
PASS
6.50E-08
PASS
+Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.129. Plot of +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
269
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.129. Raw data for +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS5 1 5V (A)
@ VS=+5V, VCM=5V
Device
0
10
557 3.50E-07 3.61E-07
563 3.49E-07 3.71E-07
564 3.58E-07 3.86E-07
567 3.49E-07 3.75E-07
569 3.62E-07 3.92E-07
570 3.47E-07 3.55E-07
571 3.55E-07 3.65E-07
572 3.57E-07 3.68E-07
573 3.42E-07 3.47E-07
574 3.53E-07 3.58E-07
584 3.37E-07 3.42E-07
585 3.56E-07 3.64E-07
Biased Statistics
Average Biased
3.54E-07 3.77E-07
Std Dev Biased
6.18E-09 1.20E-08
Ps90%/90% (+KTL) Biased
3.70E-07 4.10E-07
Ps90%/90% (-KTL) Biased
3.37E-07 3.44E-07
Un-Biased Statistics
Average Un-Biased
3.51E-07 3.58E-07
Std Dev Un-Biased
5.89E-09 8.34E-09
Ps90%/90% (+KTL) Un-Biased
3.67E-07 3.81E-07
Ps90%/90% (-KTL) Un-Biased
3.35E-07 3.36E-07
Specification MIN
-6.50E-07 -7.00E-07
Status
PASS
PASS
Specification MAX
6.50E-07 7.00E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.83E-07 3.98E-07
3.92E-07 4.04E-07
4.06E-07 4.20E-07
3.95E-07 4.07E-07
4.12E-07 4.26E-07
3.71E-07 3.89E-07
3.80E-07 4.01E-07
3.86E-07 4.06E-07
3.65E-07 3.85E-07
3.74E-07 3.95E-07
3.43E-07 3.43E-07
3.61E-07 3.66E-07
3.97E-07
1.16E-08
4.29E-07
3.66E-07
4.11E-07
1.16E-08
4.43E-07
3.79E-07
168 Hr
Anneal
70
4.00E-07
4.00E-07
4.13E-07
4.01E-07
4.20E-07
3.95E-07
4.09E-07
4.17E-07
3.94E-07
4.04E-07
3.46E-07
3.66E-07
4.39E-07
1.04E-08
4.67E-07
4.10E-07
4.38E-07
1.14E-08
4.70E-07
4.07E-07
4.07E-07
9.51E-09
4.33E-07
3.81E-07
3.75E-07 3.95E-07 4.32E-07 4.32E-07 4.04E-07
8.20E-09 8.48E-09 8.79E-09 9.46E-09 9.38E-09
3.98E-07 4.18E-07 4.56E-07 4.58E-07 4.29E-07
3.53E-07 3.72E-07 4.08E-07 4.06E-07 3.78E-07
-7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07
PASS
PASS
PASS
PASS
PASS
7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
270
50
4.28E-07
4.34E-07
4.46E-07
4.32E-07
4.54E-07
4.25E-07
4.37E-07
4.44E-07
4.22E-07
4.33E-07
3.44E-07
3.70E-07
24 Hr
Anneal
60
4.28E-07
4.31E-07
4.46E-07
4.33E-07
4.55E-07
4.25E-07
4.38E-07
4.44E-07
4.21E-07
4.32E-07
3.45E-07
3.70E-07
+Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.130. Plot of +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
271
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.130. Raw data for +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS5 2 5V (A)
@ VS=+5V, VCM=5V
Device
0
10
557 3.46E-07 3.57E-07
563 3.54E-07 3.76E-07
564 3.58E-07 3.85E-07
567 3.53E-07 3.78E-07
569 3.47E-07 3.76E-07
570 3.46E-07 3.55E-07
571 3.43E-07 3.54E-07
572 3.45E-07 3.50E-07
573 3.37E-07 3.41E-07
574 3.62E-07 3.68E-07
584 3.51E-07 3.58E-07
585 3.62E-07 3.70E-07
Biased Statistics
Average Biased
3.51E-07 3.74E-07
Std Dev Biased
4.92E-09 1.03E-08
Ps90%/90% (+KTL) Biased
3.65E-07 4.03E-07
Ps90%/90% (-KTL) Biased
3.38E-07 3.46E-07
Un-Biased Statistics
Average Un-Biased
3.47E-07 3.54E-07
Std Dev Un-Biased
9.07E-09 9.65E-09
Ps90%/90% (+KTL) Un-Biased
3.72E-07 3.80E-07
Ps90%/90% (-KTL) Un-Biased
3.22E-07 3.27E-07
Specification MIN
-6.50E-07 -7.00E-07
Status
PASS
PASS
Specification MAX
6.50E-07 7.00E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.80E-07 3.99E-07
3.96E-07 4.07E-07
4.06E-07 4.16E-07
3.96E-07 4.09E-07
3.98E-07 4.11E-07
3.71E-07 3.92E-07
3.69E-07 3.89E-07
3.69E-07 3.87E-07
3.58E-07 3.78E-07
3.84E-07 4.06E-07
3.62E-07 3.59E-07
3.68E-07 3.71E-07
3.95E-07
9.25E-09
4.20E-07
3.70E-07
4.09E-07
6.15E-09
4.25E-07
3.92E-07
168 Hr
Anneal
70
3.97E-07
4.04E-07
4.13E-07
4.04E-07
4.04E-07
4.00E-07
3.96E-07
3.98E-07
3.87E-07
4.16E-07
3.62E-07
3.72E-07
4.36E-07
5.25E-09
4.50E-07
4.21E-07
4.37E-07
6.37E-09
4.55E-07
4.20E-07
4.05E-07
5.73E-09
4.20E-07
3.89E-07
3.70E-07 3.90E-07 4.27E-07 4.27E-07 3.99E-07
9.34E-09 1.00E-08 1.22E-08 1.05E-08 1.07E-08
3.96E-07 4.18E-07 4.60E-07 4.55E-07 4.29E-07
3.45E-07 3.63E-07 3.93E-07 3.98E-07 3.70E-07
-7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07
PASS
PASS
PASS
PASS
PASS
7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
272
50
4.31E-07
4.35E-07
4.45E-07
4.34E-07
4.35E-07
4.27E-07
4.23E-07
4.25E-07
4.13E-07
4.46E-07
3.61E-07
3.74E-07
24 Hr
Anneal
60
4.30E-07
4.36E-07
4.48E-07
4.35E-07
4.37E-07
4.28E-07
4.24E-07
4.25E-07
4.14E-07
4.43E-07
3.64E-07
3.76E-07
+Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.131. Plot of +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
273
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.131. Raw data for +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS5 3 5V (A)
@ VS=+5V, VCM=5V
Device
0
10
557 3.54E-07 3.69E-07
563 3.62E-07 3.86E-07
564 3.72E-07 4.01E-07
567 3.42E-07 3.65E-07
569 3.59E-07 3.88E-07
570 3.51E-07 3.59E-07
571 3.39E-07 3.50E-07
572 3.46E-07 3.58E-07
573 3.37E-07 3.37E-07
574 3.61E-07 3.69E-07
584 3.62E-07 3.68E-07
585 3.62E-07 3.72E-07
Biased Statistics
Average Biased
3.58E-07 3.82E-07
Std Dev Biased
1.08E-08 1.47E-08
Ps90%/90% (+KTL) Biased
3.87E-07 4.22E-07
Ps90%/90% (-KTL) Biased
3.28E-07 3.42E-07
Un-Biased Statistics
Average Un-Biased
3.47E-07 3.55E-07
Std Dev Un-Biased
9.66E-09 1.19E-08
Ps90%/90% (+KTL) Un-Biased
3.73E-07 3.87E-07
Ps90%/90% (-KTL) Un-Biased
3.20E-07 3.22E-07
Specification MIN
-6.50E-07 -7.00E-07
Status
PASS
PASS
Specification MAX
6.50E-07 7.00E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.90E-07 4.06E-07
4.03E-07 4.15E-07
4.21E-07 4.33E-07
3.86E-07 3.97E-07
4.07E-07 4.19E-07
3.76E-07 3.96E-07
3.64E-07 3.83E-07
3.75E-07 3.94E-07
3.53E-07 3.73E-07
3.85E-07 4.06E-07
3.68E-07 3.68E-07
3.68E-07 3.71E-07
4.01E-07
1.40E-08
4.40E-07
3.63E-07
4.14E-07
1.38E-08
4.52E-07
3.76E-07
168 Hr
Anneal
70
4.07E-07
4.11E-07
4.27E-07
3.91E-07
4.15E-07
4.03E-07
3.89E-07
4.02E-07
3.81E-07
4.15E-07
3.69E-07
3.71E-07
4.42E-07
1.31E-08
4.78E-07
4.06E-07
4.42E-07
1.29E-08
4.78E-07
4.07E-07
4.10E-07
1.33E-08
4.47E-07
3.74E-07
3.71E-07 3.90E-07 4.26E-07 4.26E-07 3.98E-07
1.23E-08 1.27E-08 1.44E-08 1.44E-08 1.34E-08
4.04E-07 4.25E-07 4.65E-07 4.65E-07 4.35E-07
3.37E-07 3.56E-07 3.86E-07 3.86E-07 3.61E-07
-7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07
PASS
PASS
PASS
PASS
PASS
7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
274
50
4.39E-07
4.43E-07
4.60E-07
4.23E-07
4.43E-07
4.29E-07
4.18E-07
4.31E-07
4.06E-07
4.44E-07
3.69E-07
3.74E-07
24 Hr
Anneal
60
4.38E-07
4.40E-07
4.60E-07
4.25E-07
4.48E-07
4.28E-07
4.19E-07
4.32E-07
4.06E-07
4.45E-07
3.70E-07
3.76E-07
+Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.132. Plot of +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
275
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.132. Raw data for +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Input Bias Current BIAS5 4 5V (A)
@ VS=+5V, VCM=5V
Device
0
10
557 3.48E-07 3.60E-07
563 3.53E-07 3.76E-07
564 3.56E-07 3.83E-07
567 3.58E-07 3.84E-07
569 3.56E-07 3.83E-07
570 3.62E-07 3.68E-07
571 3.42E-07 3.52E-07
572 3.74E-07 3.85E-07
573 3.47E-07 3.52E-07
574 3.51E-07 3.57E-07
584 3.42E-07 3.47E-07
585 3.58E-07 3.64E-07
Biased Statistics
Average Biased
3.54E-07 3.77E-07
Std Dev Biased
3.83E-09 1.02E-08
Ps90%/90% (+KTL) Biased
3.65E-07 4.05E-07
Ps90%/90% (-KTL) Biased
3.44E-07 3.49E-07
Un-Biased Statistics
Average Un-Biased
3.55E-07 3.63E-07
Std Dev Un-Biased
1.28E-08 1.40E-08
Ps90%/90% (+KTL) Un-Biased
3.90E-07 4.01E-07
Ps90%/90% (-KTL) Un-Biased
3.20E-07 3.24E-07
Specification MIN
-6.50E-07 -7.00E-07
Status
PASS
PASS
Specification MAX
6.50E-07 7.00E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.81E-07 3.94E-07
3.95E-07 4.08E-07
4.01E-07 4.14E-07
4.03E-07 4.16E-07
4.03E-07 4.15E-07
3.86E-07 4.02E-07
3.69E-07 3.87E-07
4.03E-07 4.23E-07
3.70E-07 3.89E-07
3.71E-07 3.93E-07
3.47E-07 3.49E-07
3.64E-07 3.67E-07
3.96E-07
9.44E-09
4.22E-07
3.70E-07
4.10E-07
9.13E-09
4.35E-07
3.85E-07
168 Hr
Anneal
70
3.96E-07
4.07E-07
4.09E-07
4.13E-07
4.10E-07
4.09E-07
3.97E-07
4.34E-07
3.98E-07
4.04E-07
3.52E-07
3.69E-07
4.38E-07
7.37E-09
4.58E-07
4.18E-07
4.38E-07
7.00E-09
4.58E-07
4.19E-07
4.07E-07
6.40E-09
4.24E-07
3.89E-07
3.80E-07 3.99E-07 4.37E-07 4.37E-07 4.09E-07
1.45E-08 1.46E-08 1.58E-08 1.53E-08 1.52E-08
4.20E-07 4.39E-07 4.80E-07 4.79E-07 4.50E-07
3.40E-07 3.59E-07 3.93E-07 3.95E-07 3.67E-07
-7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07
PASS
PASS
PASS
PASS
PASS
7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
276
50
4.26E-07
4.36E-07
4.41E-07
4.44E-07
4.43E-07
4.39E-07
4.25E-07
4.63E-07
4.25E-07
4.31E-07
3.49E-07
3.71E-07
24 Hr
Anneal
60
4.27E-07
4.36E-07
4.42E-07
4.44E-07
4.43E-07
4.37E-07
4.29E-07
4.64E-07
4.26E-07
4.31E-07
3.52E-07
3.71E-07
-Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.133. Plot of -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
277
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.133. Raw data for -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS5 1 5V (A)
@ VS=+5V, VCM=5V
Device
0
10
557 3.60E-07 3.74E-07
563 3.50E-07 3.76E-07
564 3.63E-07 3.92E-07
567 3.52E-07 3.78E-07
569 3.53E-07 3.84E-07
570 3.48E-07 3.54E-07
571 3.45E-07 3.53E-07
572 3.59E-07 3.67E-07
573 3.44E-07 3.48E-07
574 3.44E-07 3.48E-07
584 3.37E-07 3.40E-07
585 3.57E-07 3.59E-07
Biased Statistics
Average Biased
3.55E-07 3.81E-07
Std Dev Biased
5.61E-09 7.30E-09
Ps90%/90% (+KTL) Biased
3.71E-07 4.01E-07
Ps90%/90% (-KTL) Biased
3.40E-07 3.61E-07
Un-Biased Statistics
Average Un-Biased
3.48E-07 3.54E-07
Std Dev Un-Biased
6.42E-09 7.81E-09
Ps90%/90% (+KTL) Un-Biased
3.66E-07 3.75E-07
Ps90%/90% (-KTL) Un-Biased
3.31E-07 3.32E-07
Specification MIN
-6.50E-07 -7.00E-07
Status
PASS
PASS
Specification MAX
6.50E-07 7.00E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.97E-07 4.13E-07
3.97E-07 4.13E-07
4.16E-07 4.29E-07
4.01E-07 4.16E-07
4.07E-07 4.22E-07
3.71E-07 3.90E-07
3.68E-07 3.86E-07
3.84E-07 4.05E-07
3.64E-07 3.83E-07
3.64E-07 3.82E-07
3.39E-07 3.38E-07
3.57E-07 3.60E-07
4.04E-07
8.08E-09
4.26E-07
3.81E-07
4.19E-07
6.82E-09
4.37E-07
4.00E-07
168 Hr
Anneal
70
4.20E-07
4.12E-07
4.24E-07
4.12E-07
4.17E-07
3.96E-07
3.97E-07
4.16E-07
3.94E-07
3.92E-07
3.37E-07
3.59E-07
4.49E-07
5.41E-09
4.64E-07
4.34E-07
4.47E-07
6.96E-09
4.66E-07
4.28E-07
4.17E-07
5.23E-09
4.31E-07
4.03E-07
3.70E-07 3.89E-07 4.26E-07 4.25E-07 3.99E-07
8.47E-09 9.12E-09 9.62E-09 9.41E-09 9.53E-09
3.93E-07 4.14E-07 4.52E-07 4.51E-07 4.25E-07
3.47E-07 3.64E-07 3.99E-07 3.99E-07 3.73E-07
-7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07
PASS
PASS
PASS
PASS
PASS
7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
278
50
4.52E-07
4.43E-07
4.56E-07
4.44E-07
4.50E-07
4.26E-07
4.22E-07
4.42E-07
4.19E-07
4.20E-07
3.39E-07
3.63E-07
24 Hr
Anneal
60
4.49E-07
4.41E-07
4.57E-07
4.40E-07
4.48E-07
4.24E-07
4.22E-07
4.41E-07
4.19E-07
4.18E-07
3.39E-07
3.64E-07
-Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.134. Plot of -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
279
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.134. Raw data for -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS5 2 5V (A)
@ VS=+5V, VCM=5V
Device
0
10
557 3.39E-07 3.57E-07
563 3.53E-07 3.76E-07
564 3.56E-07 3.85E-07
567 3.41E-07 3.69E-07
569 3.45E-07 3.75E-07
570 3.52E-07 3.56E-07
571 3.40E-07 3.49E-07
572 3.42E-07 3.48E-07
573 3.37E-07 3.35E-07
574 3.46E-07 3.51E-07
584 3.51E-07 3.54E-07
585 3.50E-07 3.52E-07
Biased Statistics
Average Biased
3.47E-07 3.72E-07
Std Dev Biased
7.21E-09 1.04E-08
Ps90%/90% (+KTL) Biased
3.67E-07 4.01E-07
Ps90%/90% (-KTL) Biased
3.27E-07 3.44E-07
Un-Biased Statistics
Average Un-Biased
3.43E-07 3.48E-07
Std Dev Un-Biased
5.76E-09 7.85E-09
Ps90%/90% (+KTL) Un-Biased
3.59E-07 3.69E-07
Ps90%/90% (-KTL) Un-Biased
3.27E-07 3.26E-07
Specification MIN
-6.50E-07 -7.00E-07
Status
PASS
PASS
Specification MAX
6.50E-07 7.00E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.79E-07 3.98E-07
3.96E-07 4.11E-07
4.08E-07 4.20E-07
3.91E-07 4.03E-07
4.00E-07 4.11E-07
3.74E-07 3.92E-07
3.65E-07 3.81E-07
3.66E-07 3.83E-07
3.51E-07 3.68E-07
3.68E-07 3.88E-07
3.55E-07 3.53E-07
3.50E-07 3.52E-07
3.95E-07
1.09E-08
4.25E-07
3.65E-07
4.09E-07
8.42E-09
4.32E-07
3.86E-07
168 Hr
Anneal
70
4.00E-07
4.08E-07
4.18E-07
4.01E-07
4.09E-07
4.02E-07
3.91E-07
3.95E-07
3.80E-07
3.99E-07
3.53E-07
3.51E-07
4.39E-07
7.43E-09
4.59E-07
4.19E-07
4.37E-07
7.68E-09
4.58E-07
4.16E-07
4.07E-07
7.34E-09
4.27E-07
3.87E-07
3.65E-07 3.82E-07 4.20E-07 4.19E-07 3.93E-07
8.32E-09 9.16E-09 9.63E-09 1.01E-08 8.48E-09
3.88E-07 4.08E-07 4.46E-07 4.46E-07 4.17E-07
3.42E-07 3.57E-07 3.93E-07 3.91E-07 3.70E-07
-7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07
PASS
PASS
PASS
PASS
PASS
7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
280
50
4.33E-07
4.40E-07
4.49E-07
4.31E-07
4.42E-07
4.27E-07
4.18E-07
4.22E-07
4.04E-07
4.28E-07
3.53E-07
3.56E-07
24 Hr
Anneal
60
4.30E-07
4.36E-07
4.48E-07
4.29E-07
4.40E-07
4.29E-07
4.17E-07
4.19E-07
4.03E-07
4.26E-07
3.54E-07
3.57E-07
-Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.135. Plot of -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
281
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.135. Raw data for -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS5 3 5V (A)
@ VS=+5V, VCM=5V
Device
0
10
557 3.46E-07 3.61E-07
563 3.60E-07 3.82E-07
564 3.73E-07 4.03E-07
567 3.38E-07 3.67E-07
569 3.48E-07 3.79E-07
570 3.47E-07 3.53E-07
571 3.38E-07 3.45E-07
572 3.59E-07 3.67E-07
573 3.35E-07 3.39E-07
574 3.65E-07 3.71E-07
584 3.50E-07 3.50E-07
585 3.58E-07 3.61E-07
Biased Statistics
Average Biased
3.53E-07 3.78E-07
Std Dev Biased
1.39E-08 1.62E-08
Ps90%/90% (+KTL) Biased
3.91E-07 4.23E-07
Ps90%/90% (-KTL) Biased
3.15E-07 3.34E-07
Un-Biased Statistics
Average Un-Biased
3.49E-07 3.55E-07
Std Dev Un-Biased
1.32E-08 1.35E-08
Ps90%/90% (+KTL) Un-Biased
3.85E-07 3.92E-07
Ps90%/90% (-KTL) Un-Biased
3.13E-07 3.18E-07
Specification MIN
-6.50E-07 -7.00E-07
Status
PASS
PASS
Specification MAX
6.50E-07 7.00E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.83E-07 4.02E-07
4.01E-07 4.15E-07
4.25E-07 4.38E-07
3.88E-07 4.02E-07
4.02E-07 4.17E-07
3.68E-07 3.87E-07
3.60E-07 3.77E-07
3.85E-07 4.02E-07
3.49E-07 3.69E-07
3.87E-07 4.07E-07
3.51E-07 3.50E-07
3.58E-07 3.61E-07
4.00E-07
1.63E-08
4.45E-07
3.55E-07
4.15E-07
1.48E-08
4.55E-07
3.74E-07
168 Hr
Anneal
70
4.05E-07
4.16E-07
4.33E-07
3.99E-07
4.12E-07
3.96E-07
3.87E-07
4.11E-07
3.78E-07
4.19E-07
3.50E-07
3.60E-07
4.45E-07
1.44E-08
4.84E-07
4.05E-07
4.42E-07
1.53E-08
4.84E-07
4.00E-07
4.13E-07
1.26E-08
4.48E-07
3.78E-07
3.70E-07 3.88E-07 4.26E-07 4.24E-07 3.98E-07
1.62E-08 1.59E-08 1.79E-08 1.86E-08 1.67E-08
4.14E-07 4.32E-07 4.75E-07 4.75E-07 4.44E-07
3.25E-07 3.45E-07 3.76E-07 3.73E-07 3.52E-07
-7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07
PASS
PASS
PASS
PASS
PASS
7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
282
50
4.37E-07
4.45E-07
4.68E-07
4.30E-07
4.44E-07
4.24E-07
4.13E-07
4.39E-07
4.04E-07
4.48E-07
3.49E-07
3.65E-07
24 Hr
Anneal
60
4.36E-07
4.41E-07
4.67E-07
4.26E-07
4.41E-07
4.21E-07
4.12E-07
4.38E-07
4.00E-07
4.46E-07
3.51E-07
3.66E-07
-Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Biased
Ps90%/90% (-KTL) Un-Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (+KTL) Un-Biased
Specification MIN
Specification MAX
1.00E-06
8.00E-07
6.00E-07
4.00E-07
2.00E-07
0.00E+00
-2.00E-07
-4.00E-07
-6.00E-07
-8.00E-07
-1.00E-06
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.136. Plot of -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
283
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.136. Raw data for -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Input Bias Current BIAS5 4 5V (A)
@ VS=+5V, VCM=5V
Device
0
10
557 3.47E-07 3.60E-07
563 3.54E-07 3.78E-07
564 3.55E-07 3.83E-07
567 3.57E-07 3.84E-07
569 3.58E-07 3.89E-07
570 3.54E-07 3.59E-07
571 3.51E-07 3.58E-07
572 3.57E-07 3.65E-07
573 3.48E-07 3.52E-07
574 3.48E-07 3.52E-07
584 3.41E-07 3.43E-07
585 3.62E-07 3.65E-07
Biased Statistics
Average Biased
3.54E-07 3.79E-07
Std Dev Biased
4.39E-09 1.09E-08
Ps90%/90% (+KTL) Biased
3.66E-07 4.09E-07
Ps90%/90% (-KTL) Biased
3.42E-07 3.49E-07
Un-Biased Statistics
Average Un-Biased
3.52E-07 3.57E-07
Std Dev Un-Biased
4.10E-09 5.47E-09
Ps90%/90% (+KTL) Un-Biased
3.63E-07 3.72E-07
Ps90%/90% (-KTL) Un-Biased
3.40E-07 3.42E-07
Specification MIN
-6.50E-07 -7.00E-07
Status
PASS
PASS
Specification MAX
6.50E-07 7.00E-07
Status
PASS
PASS
Total Dose (krad(Si))
20
30
3.83E-07 3.98E-07
4.00E-07 4.14E-07
4.07E-07 4.18E-07
4.08E-07 4.21E-07
4.14E-07 4.26E-07
3.76E-07 3.93E-07
3.75E-07 3.91E-07
3.83E-07 4.00E-07
3.68E-07 3.89E-07
3.69E-07 3.87E-07
3.44E-07 3.42E-07
3.61E-07 3.65E-07
4.02E-07
1.20E-08
4.35E-07
3.69E-07
4.15E-07
1.06E-08
4.45E-07
3.86E-07
168 Hr
Anneal
70
4.04E-07
4.15E-07
4.16E-07
4.16E-07
4.22E-07
3.98E-07
4.02E-07
4.12E-07
3.98E-07
3.95E-07
3.42E-07
3.61E-07
4.47E-07
7.09E-09
4.66E-07
4.27E-07
4.45E-07
7.85E-09
4.67E-07
4.24E-07
4.15E-07
6.33E-09
4.32E-07
3.97E-07
3.74E-07 3.92E-07 4.28E-07 4.27E-07 4.01E-07
5.94E-09 5.20E-09 5.86E-09 6.16E-09 6.88E-09
3.90E-07 4.06E-07 4.44E-07 4.44E-07 4.20E-07
3.58E-07 3.78E-07 4.12E-07 4.10E-07 3.82E-07
-7.50E-07 -7.50E-07 -8.00E-07 -8.00E-07 -8.00E-07
PASS
PASS
PASS
PASS
PASS
7.50E-07 7.50E-07 8.00E-07 8.00E-07 8.00E-07
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
284
50
4.35E-07
4.47E-07
4.49E-07
4.50E-07
4.53E-07
4.27E-07
4.27E-07
4.38E-07
4.23E-07
4.25E-07
3.43E-07
3.68E-07
24 Hr
Anneal
60
4.33E-07
4.45E-07
4.48E-07
4.46E-07
4.54E-07
4.24E-07
4.29E-07
4.37E-07
4.24E-07
4.22E-07
3.43E-07
3.69E-07
Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.137. Plot of Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
285
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.137. Raw data for Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High4 1 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=0mA
Device
0
10
20
30
50
60
70
557 4.92E-03 5.10E-03 5.16E-03 5.28E-03 5.24E-03 5.20E-03 5.14E-03
563 5.04E-03 5.42E-03 5.31E-03 5.28E-03 5.46E-03 5.61E-03 5.46E-03
564 5.14E-03 5.30E-03 5.44E-03 5.57E-03 5.55E-03 5.46E-03 5.49E-03
567 5.16E-03 5.42E-03 5.73E-03 5.42E-03 5.45E-03 5.66E-03 5.61E-03
569 5.01E-03 5.23E-03 5.21E-03 5.28E-03 5.55E-03 5.39E-03 5.26E-03
570 5.14E-03 5.18E-03 5.19E-03 5.22E-03 5.60E-03 5.30E-03 5.22E-03
571 5.29E-03 5.00E-03 5.19E-03 5.22E-03 5.67E-03 5.20E-03 5.22E-03
572 5.28E-03 5.25E-03 5.34E-03 5.40E-03 5.50E-03 5.42E-03 5.34E-03
573 5.18E-03 5.42E-03 5.48E-03 5.42E-03 5.55E-03 5.51E-03 5.32E-03
574 5.06E-03 5.00E-03 5.26E-03 4.98E-03 5.28E-03 5.30E-03 5.15E-03
584 4.82E-03 5.28E-03 5.17E-03 4.98E-03 5.14E-03 5.07E-03 4.87E-03
585 5.08E-03 5.08E-03 5.14E-03 5.15E-03 5.33E-03 5.10E-03 5.17E-03
Biased Statistics
Average Biased
5.05E-03 5.29E-03 5.37E-03 5.37E-03 5.45E-03 5.46E-03 5.39E-03
Std Dev Biased
9.84E-05 1.36E-04 2.28E-04 1.29E-04 1.27E-04 1.84E-04 1.89E-04
Ps90%/90% (+KTL) Biased
5.32E-03 5.67E-03 5.99E-03 5.72E-03 5.80E-03 5.97E-03 5.91E-03
Ps90%/90% (-KTL) Biased
4.78E-03 4.92E-03 4.75E-03 5.01E-03 5.10E-03 4.96E-03 4.87E-03
Un-Biased Statistics
Average Un-Biased
5.19E-03 5.17E-03 5.29E-03 5.25E-03 5.52E-03 5.35E-03 5.25E-03
Std Dev Un-Biased
9.70E-05 1.78E-04 1.22E-04 1.78E-04 1.48E-04 1.20E-04 7.87E-05
Ps90%/90% (+KTL) Un-Biased
5.46E-03 5.66E-03 5.63E-03 5.73E-03 5.93E-03 5.68E-03 5.47E-03
Ps90%/90% (-KTL) Un-Biased
4.92E-03 4.68E-03 4.96E-03 4.76E-03 5.11E-03 5.02E-03 5.03E-03
Specification MAX
1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
286
Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.138. Plot of Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
287
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.138. Raw data for Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High4 2 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=0mA
Device
0
10
20
30
50
60
70
557 4.86E-03 5.17E-03 5.09E-03 5.30E-03 5.31E-03 5.17E-03 5.09E-03
563 5.21E-03 5.65E-03 5.71E-03 5.50E-03 5.82E-03 5.68E-03 5.66E-03
564 5.34E-03 5.40E-03 5.71E-03 5.76E-03 5.63E-03 5.59E-03 5.49E-03
567 5.29E-03 5.40E-03 5.56E-03 5.54E-03 5.67E-03 5.57E-03 5.44E-03
569 5.11E-03 5.20E-03 5.29E-03 5.34E-03 5.51E-03 5.46E-03 5.32E-03
570 5.24E-03 5.37E-03 5.37E-03 5.39E-03 5.70E-03 5.36E-03 5.46E-03
571 5.14E-03 4.96E-03 5.16E-03 5.12E-03 5.68E-03 5.36E-03 5.10E-03
572 5.11E-03 5.20E-03 5.22E-03 5.23E-03 5.58E-03 5.25E-03 5.24E-03
573 5.21E-03 5.33E-03 5.64E-03 5.39E-03 5.46E-03 5.47E-03 5.24E-03
574 5.04E-03 5.06E-03 5.29E-03 4.98E-03 5.14E-03 5.37E-03 5.09E-03
584 5.31E-03 5.67E-03 5.48E-03 5.34E-03 5.43E-03 5.52E-03 5.32E-03
585 5.26E-03 5.35E-03 5.44E-03 5.42E-03 5.72E-03 5.37E-03 5.29E-03
Biased Statistics
Average Biased
5.16E-03 5.36E-03 5.47E-03 5.49E-03 5.59E-03 5.49E-03 5.40E-03
Std Dev Biased
1.90E-04 1.93E-04 2.74E-04 1.83E-04 1.91E-04 1.97E-04 2.12E-04
Ps90%/90% (+KTL) Biased
5.68E-03 5.89E-03 6.22E-03 5.99E-03 6.11E-03 6.04E-03 5.98E-03
Ps90%/90% (-KTL) Biased
4.64E-03 4.83E-03 4.72E-03 4.99E-03 5.06E-03 4.95E-03 4.82E-03
Un-Biased Statistics
Average Un-Biased
5.15E-03 5.18E-03 5.34E-03 5.22E-03 5.51E-03 5.36E-03 5.23E-03
Std Dev Un-Biased
7.98E-05 1.74E-04 1.87E-04 1.77E-04 2.29E-04 7.79E-05 1.50E-04
Ps90%/90% (+KTL) Un-Biased
5.37E-03 5.66E-03 5.85E-03 5.71E-03 6.14E-03 5.58E-03 5.64E-03
Ps90%/90% (-KTL) Un-Biased
4.93E-03 4.71E-03 4.82E-03 4.74E-03 4.88E-03 5.15E-03 4.82E-03
Specification MAX
1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
288
Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.139. Plot of Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
289
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.139. Raw data for Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High4 3 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=0mA
Device
0
10
20
30
50
60
70
557 4.81E-03 5.37E-03 5.21E-03 5.44E-03 5.28E-03 5.12E-03 5.31E-03
563 5.24E-03 5.64E-03 5.66E-03 5.60E-03 5.77E-03 5.94E-03 5.71E-03
564 5.23E-03 5.28E-03 5.64E-03 5.79E-03 5.62E-03 5.61E-03 5.54E-03
567 5.31E-03 5.35E-03 5.63E-03 5.54E-03 5.68E-03 5.51E-03 5.53E-03
569 5.16E-03 5.25E-03 5.29E-03 5.30E-03 5.48E-03 5.44E-03 5.26E-03
570 5.28E-03 5.33E-03 5.24E-03 5.44E-03 5.75E-03 5.39E-03 5.41E-03
571 5.13E-03 5.03E-03 5.43E-03 5.12E-03 5.68E-03 5.37E-03 5.22E-03
572 5.11E-03 5.13E-03 5.31E-03 5.30E-03 5.58E-03 5.22E-03 5.29E-03
573 5.26E-03 5.50E-03 5.51E-03 5.40E-03 5.72E-03 5.56E-03 5.29E-03
574 5.09E-03 5.03E-03 5.37E-03 5.18E-03 5.16E-03 5.25E-03 5.07E-03
584 5.29E-03 5.57E-03 5.54E-03 5.30E-03 5.43E-03 5.37E-03 5.31E-03
585 5.28E-03 5.38E-03 5.41E-03 5.42E-03 5.58E-03 5.37E-03 5.26E-03
Biased Statistics
Average Biased
5.15E-03 5.38E-03 5.49E-03 5.53E-03 5.57E-03 5.52E-03 5.47E-03
Std Dev Biased
1.97E-04 1.54E-04 2.18E-04 1.83E-04 1.92E-04 2.96E-04 1.84E-04
Ps90%/90% (+KTL) Biased
5.69E-03 5.80E-03 6.08E-03 6.03E-03 6.09E-03 6.34E-03 5.98E-03
Ps90%/90% (-KTL) Biased
4.61E-03 4.95E-03 4.89E-03 5.03E-03 5.04E-03 4.71E-03 4.96E-03
Un-Biased Statistics
Average Un-Biased
5.17E-03 5.20E-03 5.37E-03 5.29E-03 5.58E-03 5.36E-03 5.26E-03
Std Dev Un-Biased
8.91E-05 2.06E-04 1.04E-04 1.38E-04 2.42E-04 1.35E-04 1.24E-04
Ps90%/90% (+KTL) Un-Biased
5.42E-03 5.77E-03 5.66E-03 5.67E-03 6.24E-03 5.73E-03 5.60E-03
Ps90%/90% (-KTL) Un-Biased
4.93E-03 4.64E-03 5.09E-03 4.91E-03 4.91E-03 4.99E-03 4.91E-03
Specification MAX
1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
290
Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
2.50E-02
2.00E-02
1.50E-02
1.00E-02
5.00E-03
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.140. Plot of Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
291
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.140. Raw data for Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High4 4 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=0mA
Device
0
10
20
30
50
60
70
557 4.99E-03 5.23E-03 5.05E-03 5.30E-03 5.38E-03 5.15E-03 5.39E-03
563 5.08E-03 5.35E-03 5.39E-03 5.49E-03 5.50E-03 5.59E-03 5.46E-03
564 5.21E-03 5.32E-03 5.53E-03 5.86E-03 5.50E-03 5.62E-03 5.39E-03
567 5.24E-03 5.45E-03 5.75E-03 5.55E-03 5.75E-03 5.54E-03 5.54E-03
569 5.33E-03 5.27E-03 5.43E-03 5.23E-03 5.56E-03 5.64E-03 5.29E-03
570 5.26E-03 5.32E-03 5.34E-03 5.37E-03 5.75E-03 5.34E-03 5.29E-03
571 5.24E-03 5.03E-03 5.32E-03 5.25E-03 5.68E-03 5.37E-03 5.22E-03
572 5.28E-03 5.35E-03 5.51E-03 5.39E-03 5.60E-03 5.39E-03 5.41E-03
573 5.24E-03 5.37E-03 5.56E-03 5.34E-03 5.70E-03 5.66E-03 5.37E-03
574 5.06E-03 4.96E-03 5.39E-03 5.28E-03 5.28E-03 5.24E-03 5.31E-03
584 5.09E-03 5.23E-03 5.29E-03 5.07E-03 5.14E-03 5.22E-03 5.09E-03
585 5.09E-03 5.03E-03 5.09E-03 5.30E-03 5.50E-03 5.15E-03 5.15E-03
Biased Statistics
Average Biased
5.17E-03 5.32E-03 5.43E-03 5.49E-03 5.54E-03 5.51E-03 5.41E-03
Std Dev Biased
1.35E-04 8.41E-05 2.54E-04 2.47E-04 1.35E-04 2.04E-04 9.29E-05
Ps90%/90% (+KTL) Biased
5.54E-03 5.55E-03 6.13E-03 6.16E-03 5.91E-03 6.07E-03 5.67E-03
Ps90%/90% (-KTL) Biased
4.80E-03 5.09E-03 4.73E-03 4.81E-03 5.17E-03 4.95E-03 5.16E-03
Un-Biased Statistics
Average Un-Biased
5.22E-03 5.21E-03 5.42E-03 5.33E-03 5.60E-03 5.40E-03 5.32E-03
Std Dev Un-Biased
8.88E-05 1.95E-04 1.06E-04 5.94E-05 1.88E-04 1.56E-04 7.35E-05
Ps90%/90% (+KTL) Un-Biased
5.46E-03 5.74E-03 5.71E-03 5.49E-03 6.12E-03 5.83E-03 5.52E-03
Ps90%/90% (-KTL) Un-Biased
4.97E-03 4.67E-03 5.13E-03 5.16E-03 5.09E-03 4.97E-03 5.12E-03
Specification MAX
1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
292
Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
1.60E-01
1.40E-01
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.141. Plot of Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
293
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.141. Raw data for Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High5 1 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=1mA
Device
0
10
20
30
50
60
70
557 6.83E-02 6.84E-02 6.87E-02 6.93E-02 6.93E-02 6.92E-02 6.88E-02
563 7.21E-02 7.29E-02 7.32E-02 7.36E-02 7.36E-02 7.34E-02 7.35E-02
564 7.31E-02 7.40E-02 7.49E-02 7.52E-02 7.51E-02 7.48E-02 7.46E-02
567 7.35E-02 7.44E-02 7.46E-02 7.50E-02 7.49E-02 7.49E-02 7.46E-02
569 7.16E-02 7.22E-02 7.29E-02 7.31E-02 7.33E-02 7.31E-02 7.25E-02
570 7.24E-02 7.26E-02 7.33E-02 7.34E-02 7.37E-02 7.36E-02 7.32E-02
571 7.20E-02 7.21E-02 7.24E-02 7.27E-02 7.34E-02 7.30E-02 7.28E-02
572 7.21E-02 7.21E-02 7.24E-02 7.31E-02 7.34E-02 7.30E-02 7.30E-02
573 7.33E-02 7.39E-02 7.43E-02 7.42E-02 7.46E-02 7.47E-02 7.41E-02
574 7.11E-02 7.08E-02 7.16E-02 7.16E-02 7.21E-02 7.19E-02 7.15E-02
584 6.89E-02 6.91E-02 6.92E-02 6.89E-02 6.89E-02 6.85E-02 6.87E-02
585 6.87E-02 6.88E-02 6.90E-02 6.90E-02 6.90E-02 6.83E-02 6.86E-02
Biased Statistics
Average Biased
7.17E-02 7.24E-02 7.28E-02 7.32E-02 7.32E-02 7.31E-02 7.28E-02
Std Dev Biased
2.07E-03 2.36E-03 2.49E-03 2.35E-03 2.35E-03 2.33E-03 2.40E-03
Ps90%/90% (+KTL) Biased
7.74E-02 7.88E-02 7.97E-02 7.97E-02 7.97E-02 7.94E-02 7.94E-02
Ps90%/90% (-KTL) Biased
6.61E-02 6.59E-02 6.60E-02 6.68E-02 6.68E-02 6.67E-02 6.62E-02
Un-Biased Statistics
Average Un-Biased
7.22E-02 7.23E-02 7.28E-02 7.30E-02 7.35E-02 7.32E-02 7.29E-02
Std Dev Un-Biased
7.94E-04 1.11E-03 1.04E-03 9.84E-04 8.91E-04 1.03E-03 9.17E-04
Ps90%/90% (+KTL) Un-Biased
7.44E-02 7.53E-02 7.57E-02 7.57E-02 7.59E-02 7.60E-02 7.54E-02
Ps90%/90% (-KTL) Un-Biased
7.00E-02 6.92E-02 7.00E-02 7.03E-02 7.10E-02 7.04E-02 7.04E-02
Specification MAX
1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
294
Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
1.60E-01
1.40E-01
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.142. Plot of Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
295
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.142. Raw data for Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High5 2 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=1mA
Device
0
10
20
30
50
60
70
557 6.56E-02 6.60E-02 6.59E-02 6.65E-02 6.66E-02 6.62E-02 6.63E-02
563 7.36E-02 7.40E-02 7.44E-02 7.48E-02 7.51E-02 7.50E-02 7.47E-02
564 7.29E-02 7.37E-02 7.46E-02 7.49E-02 7.47E-02 7.45E-02 7.43E-02
567 7.39E-02 7.47E-02 7.53E-02 7.55E-02 7.54E-02 7.53E-02 7.51E-02
569 7.05E-02 7.14E-02 7.16E-02 7.17E-02 7.19E-02 7.18E-02 7.15E-02
570 7.21E-02 7.25E-02 7.28E-02 7.31E-02 7.36E-02 7.30E-02 7.30E-02
571 7.08E-02 7.09E-02 7.12E-02 7.16E-02 7.23E-02 7.18E-02 7.17E-02
572 6.88E-02 6.90E-02 6.94E-02 6.97E-02 7.01E-02 6.97E-02 6.97E-02
573 7.33E-02 7.37E-02 7.43E-02 7.42E-02 7.46E-02 7.45E-02 7.39E-02
574 6.85E-02 6.85E-02 6.89E-02 6.92E-02 6.95E-02 6.95E-02 6.90E-02
584 7.21E-02 7.27E-02 7.26E-02 7.26E-02 7.22E-02 7.20E-02 7.19E-02
585 7.23E-02 7.25E-02 7.28E-02 7.26E-02 7.29E-02 7.22E-02 7.24E-02
Biased Statistics
Average Biased
7.13E-02 7.20E-02 7.23E-02 7.27E-02 7.28E-02 7.25E-02 7.24E-02
Std Dev Biased
3.46E-03 3.56E-03 3.86E-03 3.74E-03 3.70E-03 3.83E-03 3.68E-03
Ps90%/90% (+KTL) Biased
8.08E-02 8.17E-02 8.29E-02 8.29E-02 8.29E-02 8.31E-02 8.24E-02
Ps90%/90% (-KTL) Biased
6.18E-02 6.22E-02 6.17E-02 6.24E-02 6.26E-02 6.20E-02 6.23E-02
Un-Biased Statistics
Average Un-Biased
7.07E-02 7.09E-02 7.13E-02 7.15E-02 7.20E-02 7.17E-02 7.15E-02
Std Dev Un-Biased
2.06E-03 2.22E-03 2.25E-03 2.16E-03 2.18E-03 2.12E-03 2.09E-03
Ps90%/90% (+KTL) Un-Biased
7.63E-02 7.70E-02 7.75E-02 7.74E-02 7.80E-02 7.75E-02 7.72E-02
Ps90%/90% (-KTL) Un-Biased
6.51E-02 6.48E-02 6.52E-02 6.56E-02 6.60E-02 6.59E-02 6.57E-02
Specification MAX
1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
296
Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
1.60E-01
1.40E-01
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.143. Plot of Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
297
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.143. Raw data for Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High5 3 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=1mA
Device
0
10
20
30
50
60
70
557 6.58E-02 6.60E-02 6.62E-02 6.67E-02 6.67E-02 6.65E-02 6.66E-02
563 7.40E-02 7.47E-02 7.50E-02 7.53E-02 7.54E-02 7.53E-02 7.53E-02
564 7.26E-02 7.34E-02 7.39E-02 7.47E-02 7.44E-02 7.42E-02 7.41E-02
567 7.37E-02 7.45E-02 7.51E-02 7.53E-02 7.53E-02 7.52E-02 7.49E-02
569 7.06E-02 7.12E-02 7.16E-02 7.16E-02 7.21E-02 7.19E-02 7.13E-02
570 7.23E-02 7.26E-02 7.30E-02 7.32E-02 7.38E-02 7.35E-02 7.34E-02
571 7.08E-02 7.07E-02 7.13E-02 7.16E-02 7.23E-02 7.18E-02 7.15E-02
572 6.88E-02 6.91E-02 6.95E-02 6.97E-02 7.01E-02 6.99E-02 6.97E-02
573 7.34E-02 7.35E-02 7.43E-02 7.43E-02 7.47E-02 7.45E-02 7.43E-02
574 6.83E-02 6.77E-02 6.89E-02 6.89E-02 6.93E-02 6.92E-02 6.89E-02
584 7.25E-02 7.29E-02 7.29E-02 7.26E-02 7.26E-02 7.21E-02 7.23E-02
585 7.22E-02 7.25E-02 7.28E-02 7.26E-02 7.24E-02 7.19E-02 7.23E-02
Biased Statistics
Average Biased
7.13E-02 7.20E-02 7.24E-02 7.27E-02 7.28E-02 7.26E-02 7.25E-02
Std Dev Biased
3.40E-03 3.61E-03 3.70E-03 3.69E-03 3.63E-03 3.68E-03 3.64E-03
Ps90%/90% (+KTL) Biased
8.07E-02 8.19E-02 8.25E-02 8.28E-02 8.27E-02 8.27E-02 8.24E-02
Ps90%/90% (-KTL) Biased
6.20E-02 6.21E-02 6.22E-02 6.26E-02 6.28E-02 6.25E-02 6.25E-02
Un-Biased Statistics
Average Un-Biased
7.07E-02 7.07E-02 7.14E-02 7.15E-02 7.20E-02 7.18E-02 7.15E-02
Std Dev Un-Biased
2.20E-03 2.38E-03 2.25E-03 2.27E-03 2.31E-03 2.27E-03 2.33E-03
Ps90%/90% (+KTL) Un-Biased
7.67E-02 7.72E-02 7.76E-02 7.78E-02 7.84E-02 7.80E-02 7.79E-02
Ps90%/90% (-KTL) Un-Biased
6.47E-02 6.42E-02 6.52E-02 6.53E-02 6.57E-02 6.55E-02 6.51E-02
Specification MAX
1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
298
Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
1.60E-01
1.40E-01
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.144. Plot of Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
299
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.144. Raw data for Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High5 4 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=1mA
Device
0
10
20
30
50
60
70
557 6.81E-02 6.86E-02 6.90E-02 6.94E-02 6.93E-02 6.92E-02 6.90E-02
563 7.21E-02 7.27E-02 7.32E-02 7.33E-02 7.36E-02 7.37E-02 7.32E-02
564 7.35E-02 7.41E-02 7.49E-02 7.54E-02 7.50E-02 7.48E-02 7.47E-02
567 7.32E-02 7.42E-02 7.47E-02 7.46E-02 7.47E-02 7.47E-02 7.44E-02
569 7.18E-02 7.25E-02 7.27E-02 7.29E-02 7.34E-02 7.30E-02 7.28E-02
570 7.23E-02 7.26E-02 7.30E-02 7.31E-02 7.36E-02 7.35E-02 7.32E-02
571 7.18E-02 7.20E-02 7.23E-02 7.27E-02 7.34E-02 7.30E-02 7.26E-02
572 7.22E-02 7.20E-02 7.24E-02 7.30E-02 7.34E-02 7.28E-02 7.28E-02
573 7.34E-02 7.36E-02 7.40E-02 7.43E-02 7.46E-02 7.43E-02 7.40E-02
574 7.08E-02 7.05E-02 7.14E-02 7.14E-02 7.18E-02 7.16E-02 7.14E-02
584 6.88E-02 6.93E-02 6.91E-02 6.90E-02 6.88E-02 6.85E-02 6.86E-02
585 6.85E-02 6.87E-02 6.89E-02 6.89E-02 6.88E-02 6.81E-02 6.84E-02
Biased Statistics
Average Biased
7.17E-02 7.24E-02 7.29E-02 7.31E-02 7.32E-02 7.31E-02 7.28E-02
Std Dev Biased
2.16E-03 2.28E-03 2.39E-03 2.30E-03 2.28E-03 2.33E-03 2.27E-03
Ps90%/90% (+KTL) Biased
7.76E-02 7.87E-02 7.94E-02 7.94E-02 7.94E-02 7.95E-02 7.90E-02
Ps90%/90% (-KTL) Biased
6.58E-02 6.62E-02 6.64E-02 6.68E-02 6.69E-02 6.67E-02 6.66E-02
Un-Biased Statistics
Average Un-Biased
7.21E-02 7.21E-02 7.26E-02 7.29E-02 7.34E-02 7.30E-02 7.28E-02
Std Dev Un-Biased
9.54E-04 1.11E-03 9.49E-04 1.07E-03 1.01E-03 1.01E-03 9.39E-04
Ps90%/90% (+KTL) Un-Biased
7.47E-02 7.52E-02 7.52E-02 7.58E-02 7.61E-02 7.58E-02 7.53E-02
Ps90%/90% (-KTL) Un-Biased
6.95E-02 6.91E-02 7.00E-02 7.00E-02 7.06E-02 7.03E-02 7.02E-02
Specification MAX
1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
300
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Swing High6 1 5V (V) @ VS=+5V
IL=2.5mA
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.145. Plot of Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
301
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.145. Raw data for Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High6 1 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=2.5mA
Device
0
10
20
30
50
60
70
557 1.23E-01 1.23E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01
563 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01
564 1.31E-01 1.32E-01 1.32E-01 1.33E-01 1.32E-01 1.32E-01 1.32E-01
567 1.30E-01 1.31E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01
569 1.28E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01
570 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.31E-01 1.30E-01 1.30E-01
571 1.28E-01 1.28E-01 1.29E-01 1.29E-01 1.30E-01 1.29E-01 1.29E-01
572 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.31E-01 1.30E-01 1.30E-01
573 1.30E-01 1.31E-01 1.31E-01 1.31E-01 1.32E-01 1.31E-01 1.31E-01
574 1.27E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01
584 1.24E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01
585 1.24E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01 1.23E-01 1.24E-01
Biased Statistics
Average Biased
1.28E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01
Std Dev Biased
3.09E-03 3.36E-03 3.45E-03 3.45E-03 3.34E-03 3.34E-03 3.35E-03
Ps90%/90% (+KTL) Biased
1.37E-01 1.38E-01 1.39E-01 1.39E-01 1.39E-01 1.39E-01 1.39E-01
Ps90%/90% (-KTL) Biased
1.20E-01 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.20E-01 1.20E-01
Un-Biased Statistics
Average Un-Biased
1.29E-01 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01
Std Dev Un-Biased
1.27E-03 1.44E-03 1.30E-03 1.34E-03 1.37E-03 1.28E-03 1.18E-03
Ps90%/90% (+KTL) Un-Biased
1.32E-01 1.33E-01 1.33E-01 1.33E-01 1.34E-01 1.33E-01 1.33E-01
Ps90%/90% (-KTL) Un-Biased
1.25E-01 1.25E-01 1.26E-01 1.26E-01 1.26E-01 1.26E-01 1.26E-01
Specification MAX
2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
302
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Swing High6 2 5V (V) @ VS=+5V
IL=2.5mA
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.146. Plot of Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
303
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.146. Raw data for Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High6 2 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=2.5mA
Device
0
10
20
30
50
60
70
557 1.19E-01 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.20E-01 1.20E-01
563 1.31E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01
564 1.30E-01 1.31E-01 1.32E-01 1.33E-01 1.32E-01 1.32E-01 1.32E-01
567 1.31E-01 1.32E-01 1.33E-01 1.33E-01 1.33E-01 1.33E-01 1.32E-01
569 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01
570 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01
571 1.27E-01 1.27E-01 1.27E-01 1.28E-01 1.29E-01 1.28E-01 1.27E-01
572 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.25E-01 1.25E-01
573 1.30E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 1.31E-01 1.31E-01
574 1.23E-01 1.23E-01 1.24E-01 1.25E-01 1.25E-01 1.24E-01 1.24E-01
584 1.29E-01 1.30E-01 1.30E-01 1.29E-01 1.29E-01 1.28E-01 1.29E-01
585 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.29E-01 1.28E-01 1.29E-01
Biased Statistics
Average Biased
1.28E-01 1.28E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01
Std Dev Biased
5.03E-03 5.24E-03 5.29E-03 5.30E-03 5.22E-03 5.40E-03 5.27E-03
Ps90%/90% (+KTL) Biased
1.41E-01 1.43E-01 1.44E-01 1.44E-01 1.44E-01 1.44E-01 1.43E-01
Ps90%/90% (-KTL) Biased
1.14E-01 1.14E-01 1.14E-01 1.15E-01 1.15E-01 1.14E-01 1.14E-01
Un-Biased Statistics
Average Un-Biased
1.27E-01 1.27E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.27E-01
Std Dev Un-Biased
2.86E-03 3.05E-03 2.95E-03 2.87E-03 2.92E-03 3.06E-03 2.90E-03
Ps90%/90% (+KTL) Un-Biased
1.35E-01 1.35E-01 1.35E-01 1.36E-01 1.36E-01 1.36E-01 1.35E-01
Ps90%/90% (-KTL) Un-Biased
1.19E-01 1.18E-01 1.19E-01 1.20E-01 1.20E-01 1.19E-01 1.19E-01
Specification MAX
2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
304
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Swing High6 3 5V (V) @ VS=+5V
IL=2.5mA
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.147. Plot of Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
305
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.147. Raw data for Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High6 3 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=2.5mA
Device
0
10
20
30
50
60
70
557 1.20E-01 1.20E-01 1.21E-01 1.21E-01 1.21E-01 1.21E-01 1.21E-01
563 1.31E-01 1.32E-01 1.33E-01 1.33E-01 1.33E-01 1.33E-01 1.33E-01
564 1.30E-01 1.31E-01 1.32E-01 1.32E-01 1.32E-01 1.31E-01 1.31E-01
567 1.31E-01 1.32E-01 1.33E-01 1.33E-01 1.33E-01 1.32E-01 1.32E-01
569 1.26E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01 1.28E-01
570 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.31E-01 1.30E-01 1.30E-01
571 1.26E-01 1.26E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.27E-01
572 1.24E-01 1.24E-01 1.25E-01 1.25E-01 1.26E-01 1.25E-01 1.25E-01
573 1.30E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 1.32E-01 1.31E-01
574 1.23E-01 1.23E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01
584 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.29E-01 1.29E-01 1.29E-01
585 1.29E-01 1.29E-01 1.30E-01 1.29E-01 1.29E-01 1.28E-01 1.29E-01
Biased Statistics
Average Biased
1.28E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01
Std Dev Biased
4.85E-03 5.10E-03 5.17E-03 5.14E-03 5.14E-03 5.11E-03 5.06E-03
Ps90%/90% (+KTL) Biased
1.41E-01 1.42E-01 1.43E-01 1.44E-01 1.43E-01 1.43E-01 1.43E-01
Ps90%/90% (-KTL) Biased
1.14E-01 1.15E-01 1.15E-01 1.15E-01 1.15E-01 1.15E-01 1.15E-01
Un-Biased Statistics
Average Un-Biased
1.27E-01 1.27E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.27E-01
Std Dev Un-Biased
3.08E-03 3.22E-03 2.93E-03 3.12E-03 3.22E-03 3.24E-03 3.13E-03
Ps90%/90% (+KTL) Un-Biased
1.35E-01 1.36E-01 1.35E-01 1.36E-01 1.37E-01 1.37E-01 1.36E-01
Ps90%/90% (-KTL) Un-Biased
1.18E-01 1.18E-01 1.19E-01 1.19E-01 1.19E-01 1.19E-01 1.19E-01
Specification MAX
2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
306
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Swing High6 4 5V (V) @ VS=+5V
IL=2.5mA
3.00E-01
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.148. Plot of Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
307
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.148. Raw data for Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing High6 4 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=2.5mA
Device
0
10
20
30
50
60
70
557 1.23E-01 1.23E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01
563 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01
564 1.31E-01 1.32E-01 1.32E-01 1.33E-01 1.33E-01 1.32E-01 1.32E-01
567 1.30E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01 1.32E-01
569 1.28E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01
570 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.30E-01
571 1.28E-01 1.28E-01 1.29E-01 1.29E-01 1.30E-01 1.29E-01 1.29E-01
572 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.29E-01 1.30E-01
573 1.30E-01 1.30E-01 1.31E-01 1.32E-01 1.32E-01 1.31E-01 1.31E-01
574 1.27E-01 1.26E-01 1.27E-01 1.28E-01 1.28E-01 1.28E-01 1.27E-01
584 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.24E-01 1.23E-01 1.24E-01
585 1.24E-01 1.24E-01 1.25E-01 1.24E-01 1.24E-01 1.23E-01 1.24E-01
Biased Statistics
Average Biased
1.28E-01 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.29E-01 1.29E-01
Std Dev Biased
3.13E-03 3.37E-03 3.54E-03 3.45E-03 3.45E-03 3.33E-03 3.41E-03
Ps90%/90% (+KTL) Biased
1.37E-01 1.38E-01 1.39E-01 1.39E-01 1.39E-01 1.39E-01 1.39E-01
Ps90%/90% (-KTL) Biased
1.20E-01 1.20E-01 1.20E-01 1.20E-01 1.20E-01 1.20E-01 1.20E-01
Un-Biased Statistics
Average Un-Biased
1.29E-01 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.29E-01 1.29E-01
Std Dev Un-Biased
1.31E-03 1.47E-03 1.38E-03 1.46E-03 1.46E-03 1.33E-03 1.35E-03
Ps90%/90% (+KTL) Un-Biased
1.32E-01 1.33E-01 1.33E-01 1.34E-01 1.34E-01 1.33E-01 1.33E-01
Ps90%/90% (-KTL) Un-Biased
1.25E-01 1.25E-01 1.26E-01 1.26E-01 1.26E-01 1.26E-01 1.26E-01
Specification MAX
2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
308
Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
7.00E-02
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.149. Plot of Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
309
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.149. Raw data for Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low4 1 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=0mA
Device
0
10
20
30
50
60
70
557 1.52E-02 1.53E-02 1.53E-02 1.56E-02 1.58E-02 1.56E-02 1.54E-02
563 1.49E-02 1.48E-02 1.51E-02 1.54E-02 1.54E-02 1.53E-02 1.51E-02
564 1.49E-02 1.51E-02 1.53E-02 1.54E-02 1.56E-02 1.53E-02 1.52E-02
567 1.49E-02 1.52E-02 1.53E-02 1.55E-02 1.55E-02 1.54E-02 1.53E-02
569 1.47E-02 1.50E-02 1.52E-02 1.52E-02 1.53E-02 1.53E-02 1.51E-02
570 1.50E-02 1.50E-02 1.52E-02 1.51E-02 1.53E-02 1.52E-02 1.51E-02
571 1.51E-02 1.51E-02 1.54E-02 1.54E-02 1.55E-02 1.54E-02 1.53E-02
572 1.52E-02 1.53E-02 1.55E-02 1.56E-02 1.57E-02 1.57E-02 1.54E-02
573 1.50E-02 1.51E-02 1.53E-02 1.53E-02 1.54E-02 1.53E-02 1.51E-02
574 1.50E-02 1.50E-02 1.52E-02 1.52E-02 1.55E-02 1.55E-02 1.51E-02
584 1.52E-02 1.53E-02 1.54E-02 1.52E-02 1.52E-02 1.51E-02 1.50E-02
585 1.51E-02 1.52E-02 1.56E-02 1.54E-02 1.54E-02 1.51E-02 1.50E-02
Biased Statistics
Average Biased
1.49E-02 1.51E-02 1.53E-02 1.54E-02 1.55E-02 1.54E-02 1.52E-02
Std Dev Biased
2.07E-04 2.05E-04 9.76E-05 1.30E-04 1.79E-04 1.39E-04 1.38E-04
Ps90%/90% (+KTL) Biased
1.55E-02 1.57E-02 1.55E-02 1.58E-02 1.60E-02 1.58E-02 1.56E-02
Ps90%/90% (-KTL) Biased
1.43E-02 1.45E-02 1.50E-02 1.50E-02 1.50E-02 1.50E-02 1.49E-02
Un-Biased Statistics
Average Un-Biased
1.51E-02 1.51E-02 1.53E-02 1.53E-02 1.55E-02 1.54E-02 1.52E-02
Std Dev Un-Biased
8.93E-05 1.36E-04 1.11E-04 1.72E-04 1.36E-04 1.89E-04 1.54E-04
Ps90%/90% (+KTL) Un-Biased
1.53E-02 1.55E-02 1.56E-02 1.58E-02 1.58E-02 1.59E-02 1.56E-02
Ps90%/90% (-KTL) Un-Biased
1.48E-02 1.47E-02 1.50E-02 1.49E-02 1.51E-02 1.49E-02 1.48E-02
Specification MAX
3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
310
Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
7.00E-02
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.150. Plot of Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
311
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.150. Raw data for Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low4 2 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=0mA
Device
0
10
20
30
50
60
70
557 1.51E-02 1.53E-02 1.55E-02 1.55E-02 1.59E-02 1.55E-02 1.55E-02
563 1.52E-02 1.53E-02 1.56E-02 1.58E-02 1.57E-02 1.57E-02 1.55E-02
564 1.50E-02 1.54E-02 1.58E-02 1.58E-02 1.58E-02 1.55E-02 1.55E-02
567 1.51E-02 1.54E-02 1.56E-02 1.57E-02 1.57E-02 1.57E-02 1.54E-02
569 1.51E-02 1.54E-02 1.57E-02 1.59E-02 1.57E-02 1.56E-02 1.55E-02
570 1.52E-02 1.52E-02 1.54E-02 1.55E-02 1.58E-02 1.57E-02 1.53E-02
571 1.52E-02 1.52E-02 1.55E-02 1.55E-02 1.55E-02 1.55E-02 1.53E-02
572 1.52E-02 1.53E-02 1.55E-02 1.55E-02 1.57E-02 1.56E-02 1.56E-02
573 1.56E-02 1.56E-02 1.59E-02 1.59E-02 1.60E-02 1.60E-02 1.58E-02
574 1.52E-02 1.53E-02 1.55E-02 1.55E-02 1.56E-02 1.56E-02 1.54E-02
584 1.52E-02 1.52E-02 1.54E-02 1.55E-02 1.52E-02 1.51E-02 1.53E-02
585 1.52E-02 1.53E-02 1.57E-02 1.54E-02 1.55E-02 1.51E-02 1.52E-02
Biased Statistics
Average Biased
1.51E-02 1.54E-02 1.56E-02 1.57E-02 1.58E-02 1.56E-02 1.55E-02
Std Dev Biased
8.72E-05 3.96E-05 1.17E-04 1.65E-04 8.38E-05 6.87E-05 6.62E-05
Ps90%/90% (+KTL) Biased
1.53E-02 1.55E-02 1.59E-02 1.62E-02 1.60E-02 1.58E-02 1.57E-02
Ps90%/90% (-KTL) Biased
1.49E-02 1.53E-02 1.53E-02 1.53E-02 1.55E-02 1.54E-02 1.53E-02
Un-Biased Statistics
Average Un-Biased
1.53E-02 1.53E-02 1.55E-02 1.56E-02 1.57E-02 1.57E-02 1.55E-02
Std Dev Un-Biased
1.72E-04 1.76E-04 1.83E-04 1.72E-04 1.90E-04 1.92E-04 1.97E-04
Ps90%/90% (+KTL) Un-Biased
1.57E-02 1.58E-02 1.60E-02 1.60E-02 1.62E-02 1.62E-02 1.60E-02
Ps90%/90% (-KTL) Un-Biased
1.48E-02 1.48E-02 1.50E-02 1.51E-02 1.52E-02 1.51E-02 1.49E-02
Specification MAX
3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
312
Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
7.00E-02
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.151. Plot of Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
313
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.151. Raw data for Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low4 3 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=0mA
Device
0
10
20
30
50
60
70
557 1.50E-02 1.50E-02 1.54E-02 1.52E-02 1.54E-02 1.53E-02 1.52E-02
563 1.49E-02 1.51E-02 1.51E-02 1.53E-02 1.54E-02 1.53E-02 1.51E-02
564 1.47E-02 1.51E-02 1.52E-02 1.53E-02 1.54E-02 1.53E-02 1.53E-02
567 1.47E-02 1.49E-02 1.51E-02 1.52E-02 1.52E-02 1.51E-02 1.49E-02
569 1.50E-02 1.53E-02 1.56E-02 1.56E-02 1.57E-02 1.55E-02 1.56E-02
570 1.47E-02 1.48E-02 1.50E-02 1.50E-02 1.49E-02 1.52E-02 1.49E-02
571 1.49E-02 1.52E-02 1.52E-02 1.53E-02 1.54E-02 1.54E-02 1.50E-02
572 1.48E-02 1.49E-02 1.52E-02 1.51E-02 1.52E-02 1.51E-02 1.51E-02
573 1.50E-02 1.51E-02 1.53E-02 1.54E-02 1.53E-02 1.54E-02 1.52E-02
574 1.50E-02 1.50E-02 1.53E-02 1.54E-02 1.56E-02 1.55E-02 1.54E-02
584 1.49E-02 1.49E-02 1.51E-02 1.52E-02 1.49E-02 1.49E-02 1.48E-02
585 1.49E-02 1.51E-02 1.54E-02 1.52E-02 1.52E-02 1.49E-02 1.49E-02
Biased Statistics
Average Biased
1.49E-02 1.51E-02 1.53E-02 1.53E-02 1.54E-02 1.53E-02 1.52E-02
Std Dev Biased
1.57E-04 1.57E-04 2.19E-04 1.31E-04 1.88E-04 1.40E-04 2.35E-04
Ps90%/90% (+KTL) Biased
1.53E-02 1.55E-02 1.59E-02 1.57E-02 1.60E-02 1.57E-02 1.59E-02
Ps90%/90% (-KTL) Biased
1.44E-02 1.47E-02 1.47E-02 1.50E-02 1.49E-02 1.49E-02 1.46E-02
Un-Biased Statistics
Average Un-Biased
1.49E-02 1.50E-02 1.52E-02 1.52E-02 1.53E-02 1.53E-02 1.51E-02
Std Dev Un-Biased
1.15E-04 1.54E-04 1.43E-04 1.74E-04 2.40E-04 1.61E-04 2.00E-04
Ps90%/90% (+KTL) Un-Biased
1.52E-02 1.54E-02 1.56E-02 1.57E-02 1.60E-02 1.58E-02 1.57E-02
Ps90%/90% (-KTL) Un-Biased
1.46E-02 1.46E-02 1.48E-02 1.47E-02 1.46E-02 1.49E-02 1.46E-02
Specification MAX
3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
314
Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
7.00E-02
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.152. Plot of Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
315
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.152. Raw data for Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low4 4 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=0mA
Device
0
10
20
30
50
60
70
557 1.52E-02 1.54E-02 1.56E-02 1.56E-02 1.60E-02 1.57E-02 1.55E-02
563 1.49E-02 1.52E-02 1.56E-02 1.55E-02 1.56E-02 1.54E-02 1.53E-02
564 1.50E-02 1.54E-02 1.56E-02 1.57E-02 1.58E-02 1.56E-02 1.55E-02
567 1.51E-02 1.53E-02 1.56E-02 1.55E-02 1.57E-02 1.57E-02 1.54E-02
569 1.50E-02 1.52E-02 1.54E-02 1.55E-02 1.56E-02 1.54E-02 1.54E-02
570 1.52E-02 1.53E-02 1.55E-02 1.56E-02 1.54E-02 1.56E-02 1.54E-02
571 1.52E-02 1.53E-02 1.56E-02 1.56E-02 1.58E-02 1.57E-02 1.55E-02
572 1.53E-02 1.54E-02 1.54E-02 1.54E-02 1.57E-02 1.57E-02 1.54E-02
573 1.53E-02 1.54E-02 1.57E-02 1.56E-02 1.57E-02 1.58E-02 1.55E-02
574 1.51E-02 1.51E-02 1.52E-02 1.52E-02 1.55E-02 1.55E-02 1.53E-02
584 1.52E-02 1.52E-02 1.52E-02 1.53E-02 1.50E-02 1.52E-02 1.50E-02
585 1.52E-02 1.53E-02 1.57E-02 1.54E-02 1.55E-02 1.53E-02 1.53E-02
Biased Statistics
Average Biased
1.51E-02 1.53E-02 1.56E-02 1.55E-02 1.57E-02 1.56E-02 1.54E-02
Std Dev Biased
1.10E-04 1.02E-04 7.22E-05 8.50E-05 1.54E-04 1.56E-04 7.77E-05
Ps90%/90% (+KTL) Biased
1.54E-02 1.56E-02 1.58E-02 1.58E-02 1.61E-02 1.60E-02 1.56E-02
Ps90%/90% (-KTL) Biased
1.48E-02 1.50E-02 1.54E-02 1.53E-02 1.53E-02 1.51E-02 1.52E-02
Un-Biased Statistics
Average Un-Biased
1.52E-02 1.53E-02 1.55E-02 1.55E-02 1.56E-02 1.57E-02 1.54E-02
Std Dev Un-Biased
9.71E-05 1.18E-04 1.93E-04 1.63E-04 1.52E-04 1.26E-04 9.72E-05
Ps90%/90% (+KTL) Un-Biased
1.55E-02 1.56E-02 1.60E-02 1.59E-02 1.60E-02 1.60E-02 1.57E-02
Ps90%/90% (-KTL) Un-Biased
1.49E-02 1.50E-02 1.49E-02 1.50E-02 1.52E-02 1.53E-02 1.51E-02
Specification MAX
3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
316
Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.153. Plot of Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
317
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.153. Raw data for Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low5 1 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=1mA
Device
0
10
20
30
50
60
70
557 3.37E-02 3.39E-02 3.41E-02 3.41E-02 3.42E-02 3.40E-02 3.41E-02
563 3.33E-02 3.35E-02 3.38E-02 3.40E-02 3.39E-02 3.38E-02 3.37E-02
564 3.36E-02 3.37E-02 3.40E-02 3.40E-02 3.41E-02 3.39E-02 3.39E-02
567 3.34E-02 3.37E-02 3.39E-02 3.40E-02 3.40E-02 3.38E-02 3.38E-02
569 3.34E-02 3.36E-02 3.38E-02 3.39E-02 3.39E-02 3.37E-02 3.36E-02
570 3.34E-02 3.36E-02 3.37E-02 3.38E-02 3.38E-02 3.38E-02 3.36E-02
571 3.38E-02 3.38E-02 3.42E-02 3.41E-02 3.42E-02 3.41E-02 3.39E-02
572 3.39E-02 3.39E-02 3.40E-02 3.41E-02 3.41E-02 3.39E-02 3.40E-02
573 3.39E-02 3.39E-02 3.41E-02 3.42E-02 3.42E-02 3.43E-02 3.40E-02
574 3.37E-02 3.35E-02 3.39E-02 3.39E-02 3.41E-02 3.39E-02 3.38E-02
584 3.36E-02 3.37E-02 3.38E-02 3.39E-02 3.38E-02 3.37E-02 3.35E-02
585 3.38E-02 3.35E-02 3.40E-02 3.40E-02 3.37E-02 3.35E-02 3.36E-02
Biased Statistics
Average Biased
3.35E-02 3.37E-02 3.39E-02 3.40E-02 3.40E-02 3.38E-02 3.38E-02
Std Dev Biased
1.76E-04 1.31E-04 1.44E-04 7.16E-05 1.39E-04 1.03E-04 1.95E-04
Ps90%/90% (+KTL) Biased
3.40E-02 3.40E-02 3.43E-02 3.42E-02 3.44E-02 3.41E-02 3.43E-02
Ps90%/90% (-KTL) Biased
3.30E-02 3.33E-02 3.35E-02 3.38E-02 3.36E-02 3.36E-02 3.33E-02
Un-Biased Statistics
Average Un-Biased
3.37E-02 3.37E-02 3.40E-02 3.40E-02 3.41E-02 3.40E-02 3.38E-02
Std Dev Un-Biased
1.82E-04 1.67E-04 1.97E-04 1.28E-04 1.70E-04 2.02E-04 1.77E-04
Ps90%/90% (+KTL) Un-Biased
3.42E-02 3.42E-02 3.45E-02 3.44E-02 3.45E-02 3.45E-02 3.43E-02
Ps90%/90% (-KTL) Un-Biased
3.32E-02 3.33E-02 3.34E-02 3.37E-02 3.36E-02 3.34E-02 3.33E-02
Specification MAX
1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
318
Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.154. Plot of Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
319
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.154. Raw data for Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low5 2 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=1mA
Device
0
10
20
30
50
60
70
557 3.37E-02 3.37E-02 3.39E-02 3.41E-02 3.42E-02 3.40E-02 3.39E-02
563 3.41E-02 3.41E-02 3.42E-02 3.44E-02 3.46E-02 3.46E-02 3.44E-02
564 3.41E-02 3.44E-02 3.46E-02 3.47E-02 3.46E-02 3.44E-02 3.45E-02
567 3.41E-02 3.45E-02 3.45E-02 3.46E-02 3.47E-02 3.46E-02 3.45E-02
569 3.42E-02 3.43E-02 3.45E-02 3.46E-02 3.47E-02 3.44E-02 3.45E-02
570 3.42E-02 3.45E-02 3.44E-02 3.44E-02 3.44E-02 3.45E-02 3.44E-02
571 3.39E-02 3.41E-02 3.44E-02 3.44E-02 3.42E-02 3.43E-02 3.40E-02
572 3.40E-02 3.40E-02 3.42E-02 3.44E-02 3.43E-02 3.43E-02 3.41E-02
573 3.50E-02 3.48E-02 3.50E-02 3.51E-02 3.51E-02 3.51E-02 3.49E-02
574 3.38E-02 3.39E-02 3.41E-02 3.41E-02 3.41E-02 3.39E-02 3.39E-02
584 3.40E-02 3.40E-02 3.43E-02 3.41E-02 3.40E-02 3.39E-02 3.39E-02
585 3.41E-02 3.43E-02 3.46E-02 3.44E-02 3.42E-02 3.41E-02 3.41E-02
Biased Statistics
Average Biased
3.40E-02 3.42E-02 3.43E-02 3.45E-02 3.45E-02 3.44E-02 3.44E-02
Std Dev Biased
2.17E-04 3.21E-04 2.87E-04 2.55E-04 1.82E-04 2.52E-04 2.72E-04
Ps90%/90% (+KTL) Biased
3.46E-02 3.51E-02 3.51E-02 3.52E-02 3.50E-02 3.51E-02 3.51E-02
Ps90%/90% (-KTL) Biased
3.34E-02 3.33E-02 3.36E-02 3.38E-02 3.40E-02 3.37E-02 3.36E-02
Un-Biased Statistics
Average Un-Biased
3.42E-02 3.42E-02 3.44E-02 3.45E-02 3.44E-02 3.44E-02 3.43E-02
Std Dev Un-Biased
4.63E-04 3.78E-04 3.51E-04 3.80E-04 3.95E-04 4.41E-04 3.85E-04
Ps90%/90% (+KTL) Un-Biased
3.54E-02 3.53E-02 3.53E-02 3.55E-02 3.55E-02 3.56E-02 3.53E-02
Ps90%/90% (-KTL) Un-Biased
3.29E-02 3.32E-02 3.34E-02 3.34E-02 3.33E-02 3.32E-02 3.32E-02
Specification MAX
1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
320
Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.155. Plot of Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
321
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.155. Raw data for Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low5 3 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=1mA
Device
0
10
20
30
50
60
70
557 3.34E-02 3.33E-02 3.38E-02 3.36E-02 3.38E-02 3.37E-02 3.36E-02
563 3.35E-02 3.37E-02 3.39E-02 3.42E-02 3.41E-02 3.41E-02 3.40E-02
564 3.37E-02 3.39E-02 3.41E-02 3.41E-02 3.41E-02 3.38E-02 3.40E-02
567 3.37E-02 3.40E-02 3.42E-02 3.42E-02 3.41E-02 3.42E-02 3.39E-02
569 3.41E-02 3.44E-02 3.45E-02 3.45E-02 3.47E-02 3.44E-02 3.43E-02
570 3.31E-02 3.35E-02 3.38E-02 3.38E-02 3.38E-02 3.39E-02 3.36E-02
571 3.39E-02 3.39E-02 3.41E-02 3.41E-02 3.42E-02 3.40E-02 3.42E-02
572 3.37E-02 3.36E-02 3.38E-02 3.39E-02 3.39E-02 3.39E-02 3.38E-02
573 3.40E-02 3.41E-02 3.43E-02 3.44E-02 3.44E-02 3.44E-02 3.41E-02
574 3.36E-02 3.36E-02 3.40E-02 3.39E-02 3.40E-02 3.38E-02 3.38E-02
584 3.33E-02 3.37E-02 3.37E-02 3.37E-02 3.35E-02 3.34E-02 3.35E-02
585 3.38E-02 3.40E-02 3.41E-02 3.39E-02 3.38E-02 3.36E-02 3.37E-02
Biased Statistics
Average Biased
3.37E-02 3.39E-02 3.41E-02 3.41E-02 3.41E-02 3.40E-02 3.39E-02
Std Dev Biased
2.62E-04 4.05E-04 2.57E-04 3.17E-04 3.17E-04 3.08E-04 2.60E-04
Ps90%/90% (+KTL) Biased
3.44E-02 3.50E-02 3.48E-02 3.50E-02 3.50E-02 3.49E-02 3.47E-02
Ps90%/90% (-KTL) Biased
3.30E-02 3.27E-02 3.34E-02 3.32E-02 3.33E-02 3.32E-02 3.32E-02
Un-Biased Statistics
Average Un-Biased
3.37E-02 3.37E-02 3.40E-02 3.40E-02 3.41E-02 3.40E-02 3.39E-02
Std Dev Un-Biased
3.29E-04 2.66E-04 2.05E-04 2.57E-04 2.53E-04 2.35E-04 2.33E-04
Ps90%/90% (+KTL) Un-Biased
3.46E-02 3.45E-02 3.46E-02 3.47E-02 3.48E-02 3.47E-02 3.45E-02
Ps90%/90% (-KTL) Un-Biased
3.28E-02 3.30E-02 3.34E-02 3.33E-02 3.34E-02 3.34E-02 3.33E-02
Specification MAX
1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
322
Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
1.20E-01
1.00E-01
8.00E-02
6.00E-02
4.00E-02
2.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.156. Plot of Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
323
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.156. Raw data for Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low5 4 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=1mA
Device
0
10
20
30
50
60
70
557 3.39E-02 3.41E-02 3.41E-02 3.43E-02 3.44E-02 3.42E-02 3.41E-02
563 3.40E-02 3.39E-02 3.40E-02 3.43E-02 3.43E-02 3.42E-02 3.41E-02
564 3.38E-02 3.41E-02 3.44E-02 3.44E-02 3.45E-02 3.42E-02 3.44E-02
567 3.39E-02 3.42E-02 3.43E-02 3.43E-02 3.44E-02 3.44E-02 3.42E-02
569 3.38E-02 3.40E-02 3.42E-02 3.42E-02 3.41E-02 3.41E-02 3.42E-02
570 3.42E-02 3.41E-02 3.43E-02 3.45E-02 3.44E-02 3.44E-02 3.42E-02
571 3.40E-02 3.43E-02 3.45E-02 3.45E-02 3.46E-02 3.44E-02 3.43E-02
572 3.41E-02 3.42E-02 3.42E-02 3.44E-02 3.45E-02 3.44E-02 3.42E-02
573 3.43E-02 3.44E-02 3.46E-02 3.47E-02 3.47E-02 3.48E-02 3.47E-02
574 3.39E-02 3.40E-02 3.42E-02 3.41E-02 3.44E-02 3.42E-02 3.40E-02
584 3.39E-02 3.40E-02 3.42E-02 3.40E-02 3.40E-02 3.38E-02 3.39E-02
585 3.39E-02 3.40E-02 3.45E-02 3.42E-02 3.41E-02 3.40E-02 3.40E-02
Biased Statistics
Average Biased
3.39E-02 3.41E-02 3.42E-02 3.43E-02 3.43E-02 3.42E-02 3.42E-02
Std Dev Biased
6.66E-05 1.03E-04 1.76E-04 9.76E-05 1.74E-04 8.73E-05 1.18E-04
Ps90%/90% (+KTL) Biased
3.40E-02 3.43E-02 3.47E-02 3.46E-02 3.48E-02 3.45E-02 3.45E-02
Ps90%/90% (-KTL) Biased
3.37E-02 3.38E-02 3.37E-02 3.40E-02 3.39E-02 3.40E-02 3.39E-02
Un-Biased Statistics
Average Un-Biased
3.41E-02 3.42E-02 3.43E-02 3.45E-02 3.45E-02 3.44E-02 3.43E-02
Std Dev Un-Biased
1.60E-04 1.63E-04 1.94E-04 2.10E-04 1.27E-04 2.04E-04 2.68E-04
Ps90%/90% (+KTL) Un-Biased
3.46E-02 3.47E-02 3.49E-02 3.50E-02 3.49E-02 3.50E-02 3.50E-02
Ps90%/90% (-KTL) Un-Biased
3.37E-02 3.38E-02 3.38E-02 3.39E-02 3.42E-02 3.39E-02 3.35E-02
Specification MAX
1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
324
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Swing Low6 1 5V (V)
@ VS=+5V IL=2.5mA
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.157. Plot of Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
325
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.157. Raw data for Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low6 1 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=2.5mA
Device
0
10
20
30
50
60
70
557 7.31E-02 7.32E-02 7.34E-02 7.36E-02 7.35E-02 7.33E-02 7.34E-02
563 7.32E-02 7.32E-02 7.36E-02 7.38E-02 7.36E-02 7.34E-02 7.35E-02
564 7.34E-02 7.36E-02 7.39E-02 7.43E-02 7.39E-02 7.37E-02 7.38E-02
567 7.32E-02 7.37E-02 7.40E-02 7.38E-02 7.37E-02 7.35E-02 7.35E-02
569 7.31E-02 7.35E-02 7.35E-02 7.36E-02 7.35E-02 7.33E-02 7.34E-02
570 7.31E-02 7.31E-02 7.33E-02 7.34E-02 7.32E-02 7.34E-02 7.32E-02
571 7.37E-02 7.36E-02 7.40E-02 7.41E-02 7.40E-02 7.38E-02 7.37E-02
572 7.39E-02 7.38E-02 7.41E-02 7.40E-02 7.40E-02 7.39E-02 7.41E-02
573 7.40E-02 7.41E-02 7.43E-02 7.43E-02 7.41E-02 7.40E-02 7.39E-02
574 7.35E-02 7.32E-02 7.37E-02 7.38E-02 7.36E-02 7.34E-02 7.33E-02
584 7.30E-02 7.34E-02 7.35E-02 7.34E-02 7.31E-02 7.29E-02 7.31E-02
585 7.31E-02 7.33E-02 7.40E-02 7.35E-02 7.32E-02 7.29E-02 7.31E-02
Biased Statistics
Average Biased
7.32E-02 7.34E-02 7.37E-02 7.38E-02 7.36E-02 7.34E-02 7.35E-02
Std Dev Biased
1.38E-04 2.29E-04 2.58E-04 2.68E-04 1.89E-04 1.53E-04 1.67E-04
Ps90%/90% (+KTL) Biased
7.36E-02 7.41E-02 7.44E-02 7.45E-02 7.42E-02 7.39E-02 7.39E-02
Ps90%/90% (-KTL) Biased
7.28E-02 7.28E-02 7.30E-02 7.31E-02 7.31E-02 7.30E-02 7.30E-02
Un-Biased Statistics
Average Un-Biased
7.36E-02 7.36E-02 7.39E-02 7.39E-02 7.38E-02 7.37E-02 7.36E-02
Std Dev Un-Biased
3.52E-04 3.93E-04 3.58E-04 3.66E-04 3.50E-04 2.88E-04 3.75E-04
Ps90%/90% (+KTL) Un-Biased
7.46E-02 7.47E-02 7.48E-02 7.49E-02 7.47E-02 7.45E-02 7.47E-02
Ps90%/90% (-KTL) Un-Biased
7.27E-02 7.25E-02 7.29E-02 7.29E-02 7.28E-02 7.29E-02 7.26E-02
Specification MAX
2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
326
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Swing Low6 2 5V (V)
@ VS=+5V IL=2.5mA
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.158. Plot of Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
327
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.158. Raw data for Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low6 2 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=2.5mA
Device
0
10
20
30
50
60
70
557 7.29E-02 7.30E-02 7.32E-02 7.32E-02 7.33E-02 7.30E-02 7.31E-02
563 7.44E-02 7.44E-02 7.47E-02 7.48E-02 7.47E-02 7.45E-02 7.47E-02
564 7.46E-02 7.47E-02 7.50E-02 7.52E-02 7.51E-02 7.46E-02 7.48E-02
567 7.46E-02 7.49E-02 7.51E-02 7.51E-02 7.50E-02 7.48E-02 7.48E-02
569 7.43E-02 7.46E-02 7.46E-02 7.48E-02 7.45E-02 7.45E-02 7.45E-02
570 7.44E-02 7.46E-02 7.47E-02 7.47E-02 7.46E-02 7.46E-02 7.44E-02
571 7.41E-02 7.40E-02 7.42E-02 7.43E-02 7.43E-02 7.42E-02 7.40E-02
572 7.38E-02 7.37E-02 7.40E-02 7.41E-02 7.41E-02 7.39E-02 7.37E-02
573 7.53E-02 7.52E-02 7.56E-02 7.56E-02 7.54E-02 7.54E-02 7.52E-02
574 7.32E-02 7.32E-02 7.35E-02 7.37E-02 7.37E-02 7.33E-02 7.33E-02
584 7.42E-02 7.43E-02 7.44E-02 7.45E-02 7.41E-02 7.39E-02 7.40E-02
585 7.42E-02 7.44E-02 7.50E-02 7.47E-02 7.47E-02 7.41E-02 7.42E-02
Biased Statistics
Average Biased
7.41E-02 7.43E-02 7.45E-02 7.46E-02 7.45E-02 7.43E-02 7.44E-02
Std Dev Biased
7.28E-04 7.62E-04 7.57E-04 8.26E-04 7.29E-04 7.46E-04 7.24E-04
Ps90%/90% (+KTL) Biased
7.61E-02 7.64E-02 7.66E-02 7.69E-02 7.65E-02 7.63E-02 7.64E-02
Ps90%/90% (-KTL) Biased
7.22E-02 7.22E-02 7.24E-02 7.23E-02 7.25E-02 7.22E-02 7.24E-02
Un-Biased Statistics
Average Un-Biased
7.42E-02 7.41E-02 7.44E-02 7.45E-02 7.44E-02 7.43E-02 7.41E-02
Std Dev Un-Biased
7.86E-04 7.82E-04 8.02E-04 7.36E-04 6.49E-04 7.95E-04 7.22E-04
Ps90%/90% (+KTL) Un-Biased
7.63E-02 7.63E-02 7.66E-02 7.65E-02 7.62E-02 7.64E-02 7.61E-02
Ps90%/90% (-KTL) Un-Biased
7.20E-02 7.20E-02 7.22E-02 7.25E-02 7.26E-02 7.21E-02 7.22E-02
Specification MAX
2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
328
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Swing Low6 3 5V (V) @ VS=+5V
IL=2.5mA
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.159. Plot of Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
329
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.159. Raw data for Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low6 3 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=2.5mA
Device
0
10
20
30
50
60
70
557 7.23E-02 7.24E-02 7.27E-02 7.25E-02 7.29E-02 7.25E-02 7.24E-02
563 7.37E-02 7.36E-02 7.40E-02 7.42E-02 7.42E-02 7.38E-02 7.39E-02
564 7.35E-02 7.38E-02 7.40E-02 7.44E-02 7.41E-02 7.39E-02 7.41E-02
567 7.38E-02 7.41E-02 7.41E-02 7.43E-02 7.43E-02 7.41E-02 7.39E-02
569 7.38E-02 7.43E-02 7.44E-02 7.43E-02 7.40E-02 7.42E-02 7.42E-02
570 7.33E-02 7.34E-02 7.35E-02 7.36E-02 7.36E-02 7.35E-02 7.32E-02
571 7.37E-02 7.36E-02 7.40E-02 7.39E-02 7.40E-02 7.37E-02 7.38E-02
572 7.32E-02 7.31E-02 7.33E-02 7.34E-02 7.34E-02 7.31E-02 7.31E-02
573 7.42E-02 7.42E-02 7.45E-02 7.45E-02 7.44E-02 7.43E-02 7.43E-02
574 7.30E-02 7.30E-02 7.34E-02 7.34E-02 7.33E-02 7.32E-02 7.31E-02
584 7.30E-02 7.34E-02 7.35E-02 7.35E-02 7.32E-02 7.29E-02 7.30E-02
585 7.36E-02 7.36E-02 7.44E-02 7.41E-02 7.36E-02 7.33E-02 7.34E-02
Biased Statistics
Average Biased
7.34E-02 7.36E-02 7.39E-02 7.39E-02 7.39E-02 7.37E-02 7.37E-02
Std Dev Biased
6.44E-04 7.25E-04 6.49E-04 8.10E-04 5.75E-04 7.03E-04 7.36E-04
Ps90%/90% (+KTL) Biased
7.52E-02 7.56E-02 7.56E-02 7.61E-02 7.55E-02 7.56E-02 7.57E-02
Ps90%/90% (-KTL) Biased
7.16E-02 7.16E-02 7.21E-02 7.17E-02 7.23E-02 7.18E-02 7.17E-02
Un-Biased Statistics
Average Un-Biased
7.35E-02 7.35E-02 7.37E-02 7.38E-02 7.37E-02 7.36E-02 7.35E-02
Std Dev Un-Biased
4.67E-04 4.71E-04 5.17E-04 4.50E-04 4.42E-04 4.74E-04 5.25E-04
Ps90%/90% (+KTL) Un-Biased
7.48E-02 7.48E-02 7.51E-02 7.50E-02 7.49E-02 7.49E-02 7.49E-02
Ps90%/90% (-KTL) Un-Biased
7.22E-02 7.22E-02 7.23E-02 7.25E-02 7.25E-02 7.23E-02 7.20E-02
Specification MAX
2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
330
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (+KTL) Biased
Output Voltage Swing Low6 4 5V (V) @ VS=+5V
IL=2.5mA
2.50E-01
2.00E-01
1.50E-01
1.00E-01
5.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.160. Plot of Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
331
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.160. Raw data for Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
Output Voltage Swing Low6 4 5V (V)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V IL=2.5mA
Device
0
10
20
30
50
60
70
557 7.34E-02 7.36E-02 7.38E-02 7.37E-02 7.38E-02 7.36E-02 7.34E-02
563 7.38E-02 7.37E-02 7.43E-02 7.44E-02 7.42E-02 7.40E-02 7.41E-02
564 7.40E-02 7.42E-02 7.46E-02 7.47E-02 7.47E-02 7.42E-02 7.45E-02
567 7.39E-02 7.44E-02 7.43E-02 7.46E-02 7.44E-02 7.43E-02 7.41E-02
569 7.37E-02 7.40E-02 7.41E-02 7.42E-02 7.39E-02 7.38E-02 7.40E-02
570 7.41E-02 7.44E-02 7.46E-02 7.45E-02 7.42E-02 7.44E-02 7.42E-02
571 7.42E-02 7.42E-02 7.47E-02 7.46E-02 7.47E-02 7.44E-02 7.43E-02
572 7.47E-02 7.45E-02 7.46E-02 7.46E-02 7.47E-02 7.45E-02 7.45E-02
573 7.49E-02 7.50E-02 7.51E-02 7.51E-02 7.49E-02 7.49E-02 7.48E-02
574 7.39E-02 7.39E-02 7.43E-02 7.43E-02 7.42E-02 7.39E-02 7.39E-02
584 7.35E-02 7.38E-02 7.39E-02 7.39E-02 7.37E-02 7.34E-02 7.35E-02
585 7.38E-02 7.38E-02 7.47E-02 7.42E-02 7.40E-02 7.36E-02 7.39E-02
Biased Statistics
Average Biased
7.38E-02 7.40E-02 7.42E-02 7.43E-02 7.42E-02 7.40E-02 7.40E-02
Std Dev Biased
2.35E-04 3.45E-04 2.97E-04 3.84E-04 3.67E-04 2.82E-04 3.78E-04
Ps90%/90% (+KTL) Biased
7.44E-02 7.49E-02 7.50E-02 7.53E-02 7.52E-02 7.48E-02 7.51E-02
Ps90%/90% (-KTL) Biased
7.31E-02 7.30E-02 7.34E-02 7.32E-02 7.32E-02 7.32E-02 7.30E-02
Un-Biased Statistics
Average Un-Biased
7.44E-02 7.44E-02 7.47E-02 7.46E-02 7.45E-02 7.44E-02 7.44E-02
Std Dev Un-Biased
4.28E-04 3.92E-04 3.10E-04 2.78E-04 3.30E-04 3.57E-04 3.16E-04
Ps90%/90% (+KTL) Un-Biased
7.55E-02 7.55E-02 7.55E-02 7.54E-02 7.54E-02 7.54E-02 7.52E-02
Ps90%/90% (-KTL) Un-Biased
7.32E-02 7.33E-02 7.38E-02 7.39E-02 7.36E-02 7.35E-02 7.35E-02
Specification MAX
2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
332
Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to
4.8V, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.50E+05
1.00E+05
5.00E+04
0.00E+00
-5.00E+04
-1.00E+05
-1.50E+05
-2.00E+05
-2.50E+05
-3.00E+05
-3.50E+05
-4.00E+05
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.161. Plot of Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
333
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.161. Raw data for Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain3 1 5V (V/mV)
@ VO=75mV to 4.8V, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Total Dose (krad(Si))
20
30
4.18E+03 7.12E+03
9.05E+04 2.83E+04
6.96E+03 8.23E+03
1.24E+04 1.37E+04
4.89E+03 5.26E+04
2.76E+03 2.75E+03
6.46E+03 5.48E+03
2.13E+03 7.46E+03
6.76E+03 1.04E+04
1.93E+04 2.07E+04
3.85E+03 3.92E+03
5.39E+03 6.88E+03
50
3.68E+03
4.63E+04
3.83E+03
1.48E+04
5.66E+03
2.35E+03
8.00E+03
3.25E+03
6.79E+03
1.07E+04
3.10E+03
1.07E+04
24 Hr
Anneal
60
7.65E+03
2.93E+04
7.53E+03
6.42E+03
9.16E+03
3.69E+03
8.99E+03
7.28E+03
5.49E+03
4.18E+04
3.05E+03
1.12E+04
168 Hr
Anneal
70
5.34E+03
1.74E+04
6.03E+03
3.79E+05
9.17E+03
3.33E+03
6.61E+03
4.20E+04
3.23E+03
1.28E+04
3.99E+03
7.21E+03
0
1.18E+04
3.67E+04
6.74E+03
1.53E+05
1.45E+04
2.49E+03
9.76E+03
1.27E+04
9.87E+03
1.21E+05
3.16E+03
5.11E+03
10
6.48E+03
9.32E+03
4.15E+03
2.25E+04
1.20E+04
3.13E+03
7.76E+03
5.68E+03
7.57E+03
4.18E+04
3.39E+03
6.59E+03
4.45E+04
6.16E+04
2.13E+05
-1.24E+05
1.09E+04
7.14E+03
3.05E+04
-8.67E+03
2.38E+04
3.74E+04
1.26E+05
-7.89E+04
2.20E+04
1.91E+04
7.43E+04
-3.03E+04
1.48E+04
1.82E+04
6.46E+04
-3.49E+04
1.20E+04
9.72E+03
3.87E+04
-1.46E+04
8.33E+04
1.65E+05
5.36E+05
-3.70E+05
3.12E+04
5.05E+04
1.70E+05
-1.07E+05
6.00E+02
PASS
1.32E+04
1.61E+04
5.74E+04
-3.10E+04
3.00E+02
PASS
7.48E+03
6.91E+03
2.64E+04
-1.15E+04
3.00E+02
PASS
9.36E+03
6.95E+03
2.84E+04
-9.68E+03
3.00E+02
PASS
6.22E+03
3.45E+03
1.57E+04
-3.23E+03
3.00E+02
PASS
1.35E+04
1.60E+04
5.73E+04
-3.04E+04
3.00E+02
PASS
1.36E+04
1.63E+04
5.84E+04
-3.12E+04
3.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
334
Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to
4.8V, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
6.00E+03
4.00E+03
2.00E+03
0.00E+00
-2.00E+03
-4.00E+03
-6.00E+03
-8.00E+03
-1.00E+04
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.162. Plot of Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
335
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.162. Raw data for Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain3 2 5V (V/mV)
@ VO=75mV to 4.8V, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.93E+03
1.38E+04
3.06E+03
2.73E+03
3.83E+03
2.20E+03
3.07E+03
2.73E+03
3.16E+03
3.60E+03
3.07E+03
1.92E+03
24 Hr
Anneal
60
1.61E+03
4.27E+03
3.57E+03
2.86E+03
3.08E+03
3.06E+03
4.19E+03
1.95E+03
3.32E+03
3.07E+03
2.88E+03
2.11E+03
168 Hr
Anneal
70
2.13E+03
4.30E+03
5.05E+03
2.68E+03
3.20E+03
2.56E+03
1.79E+03
2.19E+03
3.30E+03
3.01E+03
2.62E+03
1.94E+03
0
1.94E+03
5.73E+03
3.65E+03
2.88E+03
3.30E+03
3.05E+03
2.04E+03
2.24E+03
2.89E+03
3.03E+03
2.80E+03
2.00E+03
10
1.88E+03
4.10E+03
3.45E+03
2.75E+03
2.07E+03
2.99E+03
3.41E+03
2.13E+03
2.57E+03
3.16E+03
3.34E+03
2.09E+03
Total Dose (krad(Si))
20
30
1.88E+03 1.93E+03
3.73E+03 4.27E+03
6.50E+03 3.27E+03
2.57E+03 2.68E+03
3.43E+03 2.90E+03
2.92E+03 2.65E+03
2.14E+03 2.85E+03
2.36E+03 1.83E+03
2.60E+03 3.00E+03
2.81E+03 3.11E+03
3.59E+03 3.16E+03
2.04E+03 2.08E+03
3.50E+03
1.40E+03
7.35E+03
-3.50E+02
2.85E+03
9.30E+02
5.40E+03
3.00E+02
3.62E+03
1.77E+03
8.47E+03
-1.22E+03
3.01E+03
8.56E+02
5.36E+03
6.61E+02
5.06E+03
4.91E+03
1.85E+04
-8.40E+03
3.08E+03
9.84E+02
5.78E+03
3.80E+02
3.47E+03
1.19E+03
6.74E+03
2.06E+02
2.65E+03
4.73E+02
3.94E+03
1.35E+03
6.00E+02
PASS
2.85E+03
5.06E+02
4.24E+03
1.47E+03
3.00E+02
PASS
2.57E+03
3.20E+02
3.44E+03
1.69E+03
3.00E+02
PASS
2.69E+03
5.11E+02
4.09E+03
1.29E+03
3.00E+02
PASS
2.95E+03
5.26E+02
4.39E+03
1.51E+03
3.00E+02
PASS
3.12E+03
7.99E+02
5.31E+03
9.24E+02
3.00E+02
PASS
2.57E+03
6.09E+02
4.24E+03
9.00E+02
3.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
336
Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to
4.8V, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
3.00E+03
2.50E+03
2.00E+03
1.50E+03
1.00E+03
5.00E+02
0.00E+00
-5.00E+02
-1.00E+03
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.163. Plot of Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
337
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.163. Raw data for Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain3 3 5V (V/mV)
@ VO=75mV to 4.8V, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.76E+03
2.00E+03
2.58E+03
2.23E+03
3.35E+03
2.00E+03
2.03E+03
1.69E+03
2.47E+03
3.04E+03
2.58E+03
2.12E+03
24 Hr
Anneal
60
1.54E+03
2.15E+03
1.99E+03
2.49E+03
3.53E+03
3.64E+03
2.18E+03
1.60E+03
1.96E+03
3.16E+03
2.28E+03
2.32E+03
168 Hr
Anneal
70
1.72E+03
2.36E+03
1.76E+03
2.53E+03
4.14E+03
2.10E+03
2.45E+03
1.68E+03
1.97E+03
3.42E+03
2.65E+03
2.15E+03
0
1.91E+03
2.67E+03
1.88E+03
2.77E+03
4.78E+03
2.42E+03
2.11E+03
1.65E+03
1.99E+03
3.35E+03
2.64E+03
2.17E+03
10
1.70E+03
2.36E+03
1.93E+03
2.55E+03
3.32E+03
2.41E+03
2.15E+03
1.71E+03
1.82E+03
2.89E+03
2.69E+03
1.90E+03
Total Dose (krad(Si))
20
30
1.78E+03 2.08E+03
2.80E+03 3.08E+03
2.04E+03 2.05E+03
3.27E+03 2.40E+03
2.97E+03 3.27E+03
2.48E+03 2.18E+03
1.97E+03 2.11E+03
1.49E+03 1.94E+03
2.24E+03 1.88E+03
2.86E+03 3.07E+03
2.28E+03 2.22E+03
2.08E+03 2.41E+03
2.80E+03
1.18E+03
6.03E+03
-4.30E+02
2.37E+03
6.28E+02
4.09E+03
6.50E+02
2.57E+03
6.33E+02
4.31E+03
8.36E+02
2.58E+03
5.68E+02
4.14E+03
1.02E+03
2.38E+03
6.19E+02
4.08E+03
6.85E+02
2.34E+03
7.48E+02
4.39E+03
2.86E+02
2.50E+03
9.82E+02
5.20E+03
-1.91E+02
2.30E+03
6.49E+02
4.08E+03
5.24E+02
6.00E+02
PASS
2.20E+03
4.76E+02
3.50E+03
8.90E+02
3.00E+02
PASS
2.21E+03
5.19E+02
3.63E+03
7.84E+02
3.00E+02
PASS
2.24E+03
4.82E+02
3.56E+03
9.17E+02
3.00E+02
PASS
2.24E+03
5.24E+02
3.68E+03
8.09E+02
3.00E+02
PASS
2.51E+03
8.55E+02
4.85E+03
1.64E+02
3.00E+02
PASS
2.32E+03
6.71E+02
4.16E+03
4.84E+02
3.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
338
Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to
4.8V, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
8.00E+03
6.00E+03
4.00E+03
2.00E+03
0.00E+00
-2.00E+03
-4.00E+03
-6.00E+03
-8.00E+03
-1.00E+04
-1.20E+04
-1.40E+04
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.164. Plot of Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total
dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical
bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all
pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the
KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the
average of the data points after application of the KTL statistics on the samples irradiated in the unbiased
condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification
value as defined in the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
339
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.164. Raw data for Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus
total dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Large Signal Voltage Gain3 4 5V (V/mV)
@ VO=75mV to 4.8V, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
Total Dose (krad(Si))
20
30
3.72E+03 4.39E+03
2.96E+03 3.51E+03
1.98E+03 1.89E+03
3.67E+03 4.12E+03
7.56E+03 7.76E+03
4.41E+03 3.90E+03
2.97E+03 2.74E+03
4.48E+03 4.37E+03
2.17E+03 2.11E+03
5.15E+03 5.48E+03
2.10E+03 2.17E+03
2.63E+03 2.30E+03
50
3.25E+03
5.35E+03
2.10E+03
4.01E+03
1.33E+04
6.65E+03
2.62E+03
4.88E+03
2.06E+03
7.22E+03
1.95E+03
2.55E+03
24 Hr
Anneal
60
4.64E+03
2.64E+03
2.03E+03
3.08E+03
1.78E+04
6.34E+03
2.33E+03
3.77E+03
2.24E+03
4.72E+03
2.28E+03
2.27E+03
168 Hr
Anneal
70
3.25E+03
3.70E+03
2.11E+03
3.10E+03
5.50E+03
5.56E+03
2.66E+03
5.39E+03
2.23E+03
5.16E+03
1.99E+03
2.02E+03
0
4.80E+03
3.64E+03
2.39E+03
3.20E+03
4.69E+03
6.43E+03
2.65E+03
4.42E+03
2.39E+03
5.72E+03
2.13E+03
2.61E+03
10
3.44E+03
3.88E+03
2.17E+03
3.63E+03
7.44E+03
9.20E+03
2.56E+03
3.91E+03
2.36E+03
5.54E+03
1.95E+03
2.82E+03
3.74E+03
1.02E+03
6.54E+03
9.51E+02
4.11E+03
1.97E+03
9.52E+03
-1.30E+03
3.98E+03
2.12E+03
9.80E+03
-1.84E+03
4.33E+03
2.15E+03
1.02E+04
-1.55E+03
5.60E+03
4.46E+03
1.78E+04
-6.63E+03
6.03E+03
6.63E+03
2.42E+04
-1.21E+04
3.53E+03
1.24E+03
6.95E+03
1.21E+02
4.32E+03
1.80E+03
9.26E+03
-6.16E+02
6.00E+02
PASS
4.71E+03
2.81E+03
1.24E+04
-3.00E+03
3.00E+02
PASS
3.84E+03
1.22E+03
7.19E+03
4.77E+02
3.00E+02
PASS
3.72E+03
1.33E+03
7.38E+03
6.12E+01
3.00E+02
PASS
4.69E+03
2.32E+03
1.10E+04
-1.67E+03
3.00E+02
PASS
3.88E+03
1.72E+03
8.60E+03
-8.42E+02
3.00E+02
PASS
4.20E+03
1.62E+03
8.63E+03
-2.32E+02
3.00E+02
PASS
An ISO 9001:2008 and DSCC Certified Company
340
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio2 1 5V (dB)
@ VS=+5V, VCM=0 to +5V
1.00E+02
9.00E+01
8.00E+01
7.00E+01
6.00E+01
5.00E+01
4.00E+01
3.00E+01
2.00E+01
1.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.165. Plot of Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
341
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.165. Raw data for Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio2 1 5V (dB)
@ VS=+5V, VCM=0 to +5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
8.52E+01
9.16E+01
8.71E+01
1.19E+02
8.33E+01
9.84E+01
8.87E+01
8.63E+01
9.59E+01
9.31E+01
8.71E+01
9.39E+01
24 Hr
Anneal
60
8.52E+01
9.16E+01
8.71E+01
1.17E+02
8.33E+01
9.82E+01
8.87E+01
8.63E+01
9.60E+01
9.32E+01
8.71E+01
9.38E+01
168 Hr
Anneal
70
8.53E+01
9.11E+01
8.73E+01
1.17E+02
8.35E+01
1.00E+02
8.86E+01
8.66E+01
9.62E+01
9.30E+01
8.71E+01
9.39E+01
0
8.50E+01
9.18E+01
8.72E+01
1.15E+02
8.34E+01
1.00E+02
8.95E+01
8.67E+01
9.45E+01
9.41E+01
8.74E+01
9.46E+01
10
8.50E+01
9.18E+01
8.73E+01
1.17E+02
8.35E+01
1.00E+02
8.94E+01
8.66E+01
9.47E+01
9.40E+01
8.73E+01
9.41E+01
Total Dose (krad(Si))
20
30
8.51E+01 8.52E+01
9.18E+01 9.19E+01
8.73E+01 8.73E+01
1.18E+02 1.20E+02
8.34E+01 8.35E+01
9.98E+01 9.96E+01
8.92E+01 8.91E+01
8.65E+01 8.65E+01
9.48E+01 9.50E+01
9.39E+01 9.37E+01
8.72E+01 8.72E+01
9.41E+01 9.40E+01
9.25E+01
1.29E+01
1.28E+02
5.71E+01
9.29E+01
1.37E+01
1.31E+02
5.52E+01
9.32E+01
1.45E+01
1.33E+02
5.36E+01
9.35E+01
1.50E+01
1.35E+02
5.23E+01
9.33E+01
1.48E+01
1.34E+02
5.27E+01
9.28E+01
1.38E+01
1.31E+02
5.49E+01
9.28E+01
1.37E+01
1.30E+02
5.52E+01
9.30E+01
5.21E+00
1.07E+02
7.88E+01
7.60E+01
PASS
9.29E+01
5.19E+00
1.07E+02
7.87E+01
7.00E+01
PASS
9.28E+01
5.16E+00
1.07E+02
7.87E+01
7.00E+01
PASS
9.28E+01
5.14E+00
1.07E+02
7.87E+01
7.00E+01
PASS
9.25E+01
4.99E+00
1.06E+02
7.88E+01
7.00E+01
PASS
9.25E+01
4.99E+00
1.06E+02
7.88E+01
7.00E+01
PASS
9.29E+01
5.62E+00
1.08E+02
7.75E+01
7.00E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
342
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio2 2 5V (dB)
@ VS=+5V, VCM=0 to +5V
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.166. Plot of Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
343
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.166. Raw data for Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio2 2 5V (dB)
@ VS=+5V, VCM=0 to +5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
8.45E+01
9.36E+01
9.07E+01
8.70E+01
8.24E+01
1.13E+02
1.10E+02
8.71E+01
8.48E+01
9.49E+01
8.17E+01
8.43E+01
24 Hr
Anneal
60
8.45E+01
9.36E+01
9.06E+01
8.70E+01
8.23E+01
1.13E+02
1.09E+02
8.71E+01
8.48E+01
9.50E+01
8.16E+01
8.42E+01
168 Hr
Anneal
70
8.44E+01
9.43E+01
9.11E+01
8.75E+01
8.24E+01
1.19E+02
1.10E+02
8.72E+01
8.49E+01
9.47E+01
8.16E+01
8.42E+01
0
8.44E+01
9.38E+01
9.08E+01
8.71E+01
8.22E+01
1.39E+02
1.17E+02
8.73E+01
8.51E+01
9.37E+01
8.18E+01
8.44E+01
10
8.44E+01
9.36E+01
9.09E+01
8.72E+01
8.22E+01
1.34E+02
1.14E+02
8.72E+01
8.50E+01
9.39E+01
8.17E+01
8.43E+01
Total Dose (krad(Si))
20
30
8.45E+01 8.45E+01
9.37E+01 9.37E+01
9.08E+01 9.09E+01
8.72E+01 8.72E+01
8.23E+01 8.23E+01
1.27E+02 1.21E+02
1.14E+02 1.14E+02
8.72E+01 8.71E+01
8.50E+01 8.49E+01
9.41E+01 9.41E+01
8.17E+01 8.16E+01
8.43E+01 8.42E+01
8.76E+01
4.71E+00
1.01E+02
7.47E+01
8.77E+01
4.64E+00
1.00E+02
7.49E+01
8.77E+01
4.63E+00
1.00E+02
7.50E+01
8.77E+01
4.65E+00
1.00E+02
7.50E+01
8.76E+01
4.55E+00
1.00E+02
7.51E+01
8.76E+01
4.54E+00
1.00E+02
7.52E+01
8.79E+01
4.84E+00
1.01E+02
7.46E+01
1.04E+02
2.29E+01
1.67E+02
4.15E+01
7.60E+01
PASS
1.03E+02
2.07E+01
1.59E+02
4.60E+01
7.00E+01
PASS
1.02E+02
1.85E+01
1.52E+02
5.09E+01
7.00E+01
PASS
1.00E+02
1.64E+01
1.45E+02
5.53E+01
7.00E+01
PASS
9.80E+01
1.30E+01
1.34E+02
6.24E+01
7.00E+01
PASS
9.78E+01
1.27E+01
1.33E+02
6.29E+01
7.00E+01
PASS
9.92E+01
1.49E+01
1.40E+02
5.84E+01
7.00E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
344
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio2 3 5V (dB)
@ VS=+5V, VCM=0 to +5V
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.167. Plot of Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
345
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.167. Raw data for Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio2 3 5V (dB)
@ VS=+5V, VCM=0 to +5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
8.63E+01
8.72E+01
8.55E+01
8.75E+01
9.12E+01
8.35E+01
8.61E+01
1.29E+02
9.36E+01
9.71E+01
1.13E+02
9.20E+01
24 Hr
Anneal
60
8.63E+01
8.71E+01
8.55E+01
8.75E+01
9.11E+01
8.35E+01
8.61E+01
1.28E+02
9.37E+01
9.74E+01
1.12E+02
9.19E+01
168 Hr
Anneal
70
8.64E+01
8.73E+01
8.56E+01
8.75E+01
9.16E+01
8.39E+01
8.64E+01
1.34E+02
9.33E+01
9.83E+01
1.12E+02
9.20E+01
0
8.66E+01
8.72E+01
8.56E+01
8.72E+01
9.14E+01
8.36E+01
8.66E+01
1.12E+02
9.45E+01
9.56E+01
1.20E+02
9.26E+01
10
8.65E+01
8.72E+01
8.56E+01
8.74E+01
9.14E+01
8.35E+01
8.65E+01
1.16E+02
9.42E+01
9.59E+01
1.17E+02
9.21E+01
Total Dose (krad(Si))
20
30
8.66E+01 8.65E+01
8.71E+01 8.72E+01
8.56E+01 8.56E+01
8.74E+01 8.74E+01
9.13E+01 9.14E+01
8.35E+01 8.35E+01
8.64E+01 8.63E+01
1.17E+02 1.20E+02
9.42E+01 9.41E+01
9.61E+01 9.64E+01
1.16E+02 1.16E+02
9.22E+01 9.21E+01
8.76E+01
2.24E+00
9.38E+01
8.15E+01
8.76E+01
2.23E+00
9.38E+01
8.15E+01
8.76E+01
2.19E+00
9.36E+01
8.16E+01
8.76E+01
2.21E+00
9.37E+01
8.16E+01
8.75E+01
2.17E+00
9.35E+01
8.16E+01
8.75E+01
2.16E+00
9.34E+01
8.16E+01
8.77E+01
2.33E+00
9.41E+01
8.13E+01
9.43E+01
1.09E+01
1.24E+02
6.45E+01
7.60E+01
PASS
9.52E+01
1.27E+01
1.30E+02
6.03E+01
7.00E+01
PASS
9.55E+01
1.33E+01
1.32E+02
5.91E+01
7.00E+01
PASS
9.61E+01
1.46E+01
1.36E+02
5.62E+01
7.00E+01
PASS
9.80E+01
1.85E+01
1.49E+02
4.74E+01
7.00E+01
PASS
9.78E+01
1.79E+01
1.47E+02
4.86E+01
7.00E+01
PASS
9.92E+01
2.04E+01
1.55E+02
4.32E+01
7.00E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
346
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Common Mode Rejection Ratio2 4 5V (dB)
@ VS=+5V, VCM=0 to +5V
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.168. Plot of Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose.
The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias
while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied
to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
347
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.168. Raw data for Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total
dose, including the statistical analysis, specification and the status of the testing (pass/fail).
Common Mode Rejection Ratio2 4 5V (dB)
@ VS=+5V, VCM=0 to +5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
8.90E+01
9.84E+01
1.03E+02
9.96E+01
1.00E+02
1.16E+02
9.11E+01
9.48E+01
9.91E+01
8.57E+01
8.78E+01
8.93E+01
24 Hr
Anneal
60
8.91E+01
9.80E+01
1.04E+02
9.98E+01
9.99E+01
1.16E+02
9.12E+01
9.49E+01
9.90E+01
8.57E+01
8.77E+01
8.91E+01
168 Hr
Anneal
70
8.91E+01
9.90E+01
1.01E+02
9.89E+01
1.03E+02
1.14E+02
9.19E+01
9.53E+01
9.84E+01
8.54E+01
8.77E+01
8.91E+01
0
8.88E+01
9.90E+01
1.04E+02
9.90E+01
9.97E+01
1.26E+02
9.18E+01
9.69E+01
1.00E+02
8.59E+01
8.80E+01
8.96E+01
10
8.88E+01
9.88E+01
1.03E+02
9.88E+01
1.00E+02
1.28E+02
9.18E+01
9.63E+01
9.97E+01
8.59E+01
8.79E+01
8.92E+01
Total Dose (krad(Si))
20
30
8.87E+01 8.88E+01
9.89E+01 9.92E+01
1.03E+02 1.03E+02
9.89E+01 9.89E+01
1.00E+02 1.00E+02
1.36E+02 1.33E+02
9.16E+01 9.15E+01
9.60E+01 9.57E+01
1.00E+02 1.00E+02
8.59E+01 8.58E+01
8.79E+01 8.78E+01
8.92E+01 8.92E+01
9.81E+01
5.63E+00
1.14E+02
8.27E+01
9.80E+01
5.45E+00
1.13E+02
8.30E+01
9.81E+01
5.55E+00
1.13E+02
8.29E+01
9.81E+01
5.41E+00
1.13E+02
8.32E+01
9.81E+01
5.42E+00
1.13E+02
8.32E+01
9.83E+01
5.66E+00
1.14E+02
8.27E+01
9.83E+01
5.41E+00
1.13E+02
8.34E+01
1.00E+02
1.56E+01
1.43E+02
5.74E+01
7.60E+01
PASS
1.00E+02
1.63E+01
1.45E+02
5.56E+01
7.00E+01
PASS
1.02E+02
1.99E+01
1.57E+02
4.73E+01
7.00E+01
PASS
1.01E+02
1.84E+01
1.52E+02
5.07E+01
7.00E+01
PASS
9.74E+01
1.16E+01
1.29E+02
6.55E+01
7.00E+01
PASS
9.74E+01
1.16E+01
1.29E+02
6.56E+01
7.00E+01
PASS
9.69E+01
1.05E+01
1.26E+02
6.82E+01
7.00E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
348
CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.00E+02
9.00E+01
8.00E+01
7.00E+01
6.00E+01
5.00E+01
4.00E+01
3.00E+01
2.00E+01
1.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.169. Plot of CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
349
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.169. Raw data for CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
CMRR Match2 1 to 4 5V (dB)
@ VS=+5V, VCM=0 to +5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
8.09E+01
9.69E+01
8.59E+01
9.87E+01
8.47E+01
9.96E+01
1.01E+02
9.05E+01
9.13E+01
9.05E+01
1.10E+02
9.70E+01
24 Hr
Anneal
60
8.09E+01
9.72E+01
8.60E+01
9.87E+01
8.47E+01
9.94E+01
1.01E+02
9.03E+01
9.14E+01
9.04E+01
1.10E+02
9.66E+01
168 Hr
Anneal
70
8.10E+01
9.56E+01
8.57E+01
9.79E+01
8.45E+01
1.03E+02
9.85E+01
9.05E+01
9.13E+01
9.02E+01
1.10E+02
9.67E+01
0
8.07E+01
9.68E+01
8.60E+01
9.77E+01
8.49E+01
9.99E+01
1.02E+02
9.00E+01
9.08E+01
9.02E+01
1.10E+02
9.67E+01
10
8.07E+01
9.68E+01
8.60E+01
9.78E+01
8.49E+01
9.97E+01
1.02E+02
9.00E+01
9.08E+01
9.02E+01
1.10E+02
9.64E+01
Total Dose (krad(Si))
20
30
8.07E+01 8.08E+01
9.69E+01 9.68E+01
8.60E+01 8.60E+01
9.80E+01 9.81E+01
8.48E+01 8.48E+01
9.99E+01 9.98E+01
1.02E+02 1.01E+02
9.01E+01 9.02E+01
9.10E+01 9.12E+01
9.03E+01 9.03E+01
1.10E+02 1.10E+02
9.65E+01 9.66E+01
8.92E+01
7.60E+00
1.10E+02
6.84E+01
8.92E+01
7.64E+00
1.10E+02
6.83E+01
8.93E+01
7.74E+00
1.10E+02
6.81E+01
8.93E+01
7.72E+00
1.10E+02
6.81E+01
8.94E+01
7.91E+00
1.11E+02
6.77E+01
8.95E+01
7.94E+00
1.11E+02
6.77E+01
8.89E+01
7.39E+00
1.09E+02
6.86E+01
9.46E+01
5.94E+00
1.11E+02
7.83E+01
7.50E+01
PASS
9.45E+01
5.80E+00
1.10E+02
7.86E+01
7.00E+01
PASS
9.46E+01
5.70E+00
1.10E+02
7.90E+01
7.00E+01
PASS
9.46E+01
5.56E+00
1.10E+02
7.93E+01
7.00E+01
PASS
9.46E+01
5.24E+00
1.09E+02
8.02E+01
7.00E+01
PASS
9.44E+01
5.17E+00
1.09E+02
8.03E+01
7.00E+01
PASS
9.46E+01
5.61E+00
1.10E+02
7.92E+01
7.00E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
350
CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.170. Plot of CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
351
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.170. Raw data for CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
CMRR Match2 2 to 3 5V (dB)
@ VS=+5V, VCM=0 to +5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
9.90E+01
9.28E+01
9.25E+01
1.11E+02
8.63E+01
8.38E+01
8.67E+01
8.72E+01
8.87E+01
1.08E+02
8.19E+01
8.88E+01
24 Hr
Anneal
60
9.90E+01
9.27E+01
9.24E+01
1.11E+02
8.63E+01
8.38E+01
8.67E+01
8.72E+01
8.86E+01
1.07E+02
8.19E+01
8.89E+01
168 Hr
Anneal
70
9.80E+01
9.24E+01
9.22E+01
1.30E+02
8.60E+01
8.40E+01
8.70E+01
8.73E+01
8.90E+01
1.04E+02
8.19E+01
8.88E+01
0
9.72E+01
9.27E+01
9.24E+01
1.21E+02
8.58E+01
8.36E+01
8.69E+01
8.68E+01
8.87E+01
1.08E+02
8.19E+01
8.87E+01
10
9.77E+01
9.29E+01
9.24E+01
1.19E+02
8.59E+01
8.36E+01
8.69E+01
8.69E+01
8.87E+01
1.08E+02
8.18E+01
8.88E+01
Total Dose (krad(Si))
20
30
9.79E+01 9.82E+01
9.26E+01 9.27E+01
9.25E+01 9.24E+01
1.18E+02 1.17E+02
8.61E+01 8.61E+01
8.36E+01 8.36E+01
8.67E+01 8.67E+01
8.69E+01 8.70E+01
8.86E+01 8.86E+01
1.08E+02 1.07E+02
8.18E+01 8.18E+01
8.87E+01 8.87E+01
9.79E+01
1.37E+01
1.35E+02
6.04E+01
9.76E+01
1.28E+01
1.33E+02
6.26E+01
9.74E+01
1.23E+01
1.31E+02
6.38E+01
9.73E+01
1.19E+01
1.30E+02
6.46E+01
9.63E+01
9.41E+00
1.22E+02
7.05E+01
9.64E+01
9.51E+00
1.22E+02
7.03E+01
9.96E+01
1.73E+01
1.47E+02
5.23E+01
9.08E+01
9.78E+00
1.18E+02
6.39E+01
7.50E+01
PASS
9.07E+01
9.66E+00
1.17E+02
6.42E+01
7.00E+01
PASS
9.07E+01
9.65E+00
1.17E+02
6.42E+01
7.00E+01
PASS
9.05E+01
9.33E+00
1.16E+02
6.49E+01
7.00E+01
PASS
9.08E+01
9.70E+00
1.17E+02
6.43E+01
7.00E+01
PASS
9.07E+01
9.43E+00
1.17E+02
6.49E+01
7.00E+01
PASS
9.03E+01
8.02E+00
1.12E+02
6.83E+01
7.00E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
352
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio2 1 (dB)
@ VS=+4.5V to +12V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.171. Plot of Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
353
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.171. Raw data for Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio2 1 (dB)
@ VS=+4.5V to +12V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.29E+02
1.12E+02
1.17E+02
1.18E+02
1.18E+02
1.10E+02
1.27E+02
1.11E+02
1.11E+02
1.22E+02
1.13E+02
1.15E+02
24 Hr
Anneal
60
1.29E+02
1.12E+02
1.17E+02
1.18E+02
1.18E+02
1.10E+02
1.27E+02
1.11E+02
1.11E+02
1.22E+02
1.13E+02
1.15E+02
168 Hr
Anneal
70
1.29E+02
1.12E+02
1.17E+02
1.18E+02
1.18E+02
1.10E+02
1.25E+02
1.11E+02
1.11E+02
1.22E+02
1.13E+02
1.15E+02
0
1.28E+02
1.12E+02
1.16E+02
1.18E+02
1.18E+02
1.10E+02
1.25E+02
1.11E+02
1.11E+02
1.22E+02
1.13E+02
1.15E+02
10
1.29E+02
1.12E+02
1.16E+02
1.18E+02
1.18E+02
1.10E+02
1.25E+02
1.11E+02
1.11E+02
1.22E+02
1.13E+02
1.15E+02
Total Dose (krad(Si))
20
30
1.29E+02 1.29E+02
1.12E+02 1.12E+02
1.17E+02 1.17E+02
1.18E+02 1.18E+02
1.18E+02 1.18E+02
1.10E+02 1.10E+02
1.25E+02 1.25E+02
1.11E+02 1.11E+02
1.11E+02 1.11E+02
1.22E+02 1.22E+02
1.13E+02 1.13E+02
1.15E+02 1.15E+02
1.18E+02
5.93E+00
1.35E+02
1.02E+02
1.18E+02
6.20E+00
1.35E+02
1.01E+02
1.19E+02
6.16E+00
1.35E+02
1.02E+02
1.19E+02
6.16E+00
1.35E+02
1.02E+02
1.19E+02
6.41E+00
1.36E+02
1.01E+02
1.19E+02
6.14E+00
1.35E+02
1.02E+02
1.19E+02
6.43E+00
1.36E+02
1.01E+02
1.16E+02
6.98E+00
1.35E+02
9.67E+01
8.80E+01
PASS
1.16E+02
6.79E+00
1.34E+02
9.72E+01
8.80E+01
PASS
1.16E+02
7.15E+00
1.36E+02
9.63E+01
8.80E+01
PASS
1.16E+02
7.00E+00
1.35E+02
9.67E+01
8.80E+01
PASS
1.16E+02
7.68E+00
1.37E+02
9.52E+01
8.80E+01
PASS
1.16E+02
7.53E+00
1.37E+02
9.57E+01
8.80E+01
PASS
1.16E+02
7.13E+00
1.36E+02
9.65E+01
8.80E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
354
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio2 2 (dB)
@ VS=+4.5V to +12V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.172. Plot of Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
355
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.172. Raw data for Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio2 2 (dB)
@ VS=+4.5V to +12V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.11E+02
1.18E+02
1.19E+02
1.14E+02
1.16E+02
1.13E+02
1.10E+02
1.18E+02
1.09E+02
1.10E+02
1.16E+02
1.10E+02
24 Hr
Anneal
60
1.11E+02
1.18E+02
1.18E+02
1.14E+02
1.16E+02
1.13E+02
1.10E+02
1.19E+02
1.09E+02
1.10E+02
1.16E+02
1.10E+02
168 Hr
Anneal
70
1.11E+02
1.18E+02
1.19E+02
1.14E+02
1.16E+02
1.13E+02
1.10E+02
1.18E+02
1.09E+02
1.10E+02
1.16E+02
1.10E+02
0
1.11E+02
1.17E+02
1.18E+02
1.14E+02
1.16E+02
1.13E+02
1.10E+02
1.18E+02
1.08E+02
1.10E+02
1.16E+02
1.10E+02
10
1.11E+02
1.18E+02
1.18E+02
1.13E+02
1.16E+02
1.13E+02
1.10E+02
1.18E+02
1.08E+02
1.10E+02
1.16E+02
1.10E+02
Total Dose (krad(Si))
20
30
1.11E+02 1.11E+02
1.17E+02 1.18E+02
1.18E+02 1.18E+02
1.13E+02 1.13E+02
1.16E+02 1.16E+02
1.13E+02 1.13E+02
1.10E+02 1.10E+02
1.18E+02 1.18E+02
1.08E+02 1.08E+02
1.10E+02 1.10E+02
1.16E+02 1.16E+02
1.10E+02 1.10E+02
1.15E+02
2.94E+00
1.23E+02
1.07E+02
1.15E+02
3.04E+00
1.24E+02
1.07E+02
1.15E+02
2.91E+00
1.23E+02
1.07E+02
1.15E+02
3.14E+00
1.24E+02
1.07E+02
1.15E+02
3.01E+00
1.24E+02
1.07E+02
1.15E+02
2.99E+00
1.24E+02
1.07E+02
1.15E+02
3.06E+00
1.24E+02
1.07E+02
1.12E+02
3.96E+00
1.23E+02
1.01E+02
8.80E+01
PASS
1.12E+02
3.96E+00
1.23E+02
1.01E+02
8.80E+01
PASS
1.12E+02
3.96E+00
1.23E+02
1.01E+02
8.80E+01
PASS
1.12E+02
3.91E+00
1.23E+02
1.01E+02
8.80E+01
PASS
1.12E+02
3.94E+00
1.23E+02
1.01E+02
8.80E+01
PASS
1.12E+02
4.02E+00
1.23E+02
1.01E+02
8.80E+01
PASS
1.12E+02
3.91E+00
1.23E+02
1.01E+02
8.80E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
356
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio2 3 (dB)
@ VS=+4.5V to +12V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.173. Plot of Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
357
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.173. Raw data for Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio2 3 (dB)
@ VS=+4.5V to +12V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.11E+02
1.43E+02
1.12E+02
1.11E+02
1.12E+02
1.24E+02
1.06E+02
1.17E+02
1.08E+02
1.14E+02
1.15E+02
1.16E+02
24 Hr
Anneal
60
1.11E+02
1.43E+02
1.12E+02
1.11E+02
1.12E+02
1.24E+02
1.06E+02
1.17E+02
1.08E+02
1.14E+02
1.15E+02
1.16E+02
168 Hr
Anneal
70
1.11E+02
1.43E+02
1.12E+02
1.11E+02
1.12E+02
1.24E+02
1.06E+02
1.17E+02
1.08E+02
1.14E+02
1.15E+02
1.16E+02
0
1.11E+02
1.40E+02
1.11E+02
1.11E+02
1.12E+02
1.24E+02
1.06E+02
1.17E+02
1.08E+02
1.14E+02
1.15E+02
1.16E+02
10
1.11E+02
1.37E+02
1.11E+02
1.11E+02
1.12E+02
1.25E+02
1.06E+02
1.17E+02
1.08E+02
1.14E+02
1.15E+02
1.16E+02
Total Dose (krad(Si))
20
30
1.11E+02 1.11E+02
1.43E+02 1.42E+02
1.11E+02 1.12E+02
1.11E+02 1.11E+02
1.12E+02 1.12E+02
1.26E+02 1.24E+02
1.06E+02 1.06E+02
1.17E+02 1.17E+02
1.08E+02 1.08E+02
1.14E+02 1.14E+02
1.15E+02 1.15E+02
1.16E+02 1.16E+02
1.17E+02
1.30E+01
1.53E+02
8.16E+01
1.17E+02
1.13E+01
1.48E+02
8.55E+01
1.18E+02
1.43E+01
1.57E+02
7.87E+01
1.18E+02
1.36E+01
1.55E+02
8.03E+01
1.18E+02
1.42E+01
1.57E+02
7.91E+01
1.18E+02
1.40E+01
1.56E+02
7.96E+01
1.18E+02
1.40E+01
1.56E+02
7.95E+01
1.14E+02
7.20E+00
1.33E+02
9.39E+01
8.80E+01
PASS
1.14E+02
7.63E+00
1.35E+02
9.30E+01
8.80E+01
PASS
1.14E+02
7.82E+00
1.35E+02
9.26E+01
8.80E+01
PASS
1.14E+02
7.23E+00
1.33E+02
9.38E+01
8.80E+01
PASS
1.14E+02
7.20E+00
1.34E+02
9.41E+01
8.80E+01
PASS
1.14E+02
7.41E+00
1.34E+02
9.36E+01
8.80E+01
PASS
1.14E+02
7.19E+00
1.33E+02
9.41E+01
8.80E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
358
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
Power Supply Rejection Ratio2 4 (dB)
@ VS=+4.5V to +12V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.174. Plot of Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
359
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.174. Raw data for Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Power Supply Rejection Ratio2 4 (dB)
@ VS=+4.5V to +12V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
50
1.13E+02
1.18E+02
1.15E+02
1.14E+02
1.13E+02
1.16E+02
1.26E+02
1.17E+02
1.12E+02
1.21E+02
1.06E+02
1.14E+02
24 Hr
Anneal
60
1.13E+02
1.18E+02
1.15E+02
1.14E+02
1.13E+02
1.16E+02
1.26E+02
1.17E+02
1.12E+02
1.21E+02
1.06E+02
1.14E+02
168 Hr
Anneal
70
1.13E+02
1.18E+02
1.15E+02
1.14E+02
1.13E+02
1.16E+02
1.27E+02
1.18E+02
1.12E+02
1.21E+02
1.06E+02
1.14E+02
0
1.13E+02
1.18E+02
1.15E+02
1.14E+02
1.13E+02
1.16E+02
1.26E+02
1.17E+02
1.12E+02
1.20E+02
1.06E+02
1.14E+02
10
1.13E+02
1.18E+02
1.15E+02
1.14E+02
1.13E+02
1.16E+02
1.26E+02
1.17E+02
1.12E+02
1.20E+02
1.06E+02
1.14E+02
Total Dose (krad(Si))
20
30
1.13E+02 1.13E+02
1.18E+02 1.18E+02
1.15E+02 1.15E+02
1.14E+02 1.14E+02
1.13E+02 1.13E+02
1.16E+02 1.16E+02
1.27E+02 1.26E+02
1.17E+02 1.17E+02
1.12E+02 1.12E+02
1.21E+02 1.20E+02
1.06E+02 1.06E+02
1.14E+02 1.14E+02
1.14E+02
2.10E+00
1.20E+02
1.09E+02
1.14E+02
2.13E+00
1.20E+02
1.09E+02
1.15E+02
2.11E+00
1.20E+02
1.09E+02
1.14E+02
2.13E+00
1.20E+02
1.09E+02
1.15E+02
2.25E+00
1.21E+02
1.09E+02
1.15E+02
2.28E+00
1.21E+02
1.08E+02
1.15E+02
2.15E+00
1.21E+02
1.09E+02
1.18E+02
5.40E+00
1.33E+02
1.04E+02
8.80E+01
PASS
1.18E+02
5.43E+00
1.33E+02
1.04E+02
8.80E+01
PASS
1.19E+02
5.45E+00
1.34E+02
1.04E+02
8.80E+01
PASS
1.18E+02
5.43E+00
1.33E+02
1.03E+02
8.80E+01
PASS
1.18E+02
5.14E+00
1.33E+02
1.04E+02
8.80E+01
PASS
1.18E+02
5.32E+00
1.33E+02
1.04E+02
8.80E+01
PASS
1.19E+02
5.44E+00
1.34E+02
1.04E+02
8.80E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
360
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.175. Plot of PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
361
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.175. Raw data for PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
PSRR Match2 1 to 4 (dB)
@ VS=+4.5V to +12V
Device
557
563
564
567
569
570
571
572
573
574
584
585
0
1.14E+02
1.17E+02
1.33E+02
1.23E+02
1.20E+02
1.17E+02
1.41E+02
1.17E+02
1.35E+02
1.34E+02
1.12E+02
1.35E+02
Biased Statistics
Average Biased
1.21E+02
Std Dev Biased
7.04E+00
Ps90%/90% (+KTL) Biased
1.41E+02
Ps90%/90% (-KTL) Biased
1.02E+02
Un-Biased Statistics
Average Un-Biased
1.29E+02
Std Dev Un-Biased
1.12E+01
Ps90%/90% (+KTL) Un-Biased 1.59E+02
Ps90%/90% (-KTL) Un-Biased
9.79E+01
Specification MIN
8.20E+01
Status
PASS
50
1.14E+02
1.17E+02
1.31E+02
1.23E+02
1.21E+02
1.17E+02
1.44E+02
1.16E+02
1.33E+02
1.38E+02
1.12E+02
1.33E+02
24 Hr
Anneal
60
1.14E+02
1.18E+02
1.31E+02
1.24E+02
1.20E+02
1.17E+02
1.53E+02
1.17E+02
1.33E+02
1.36E+02
1.12E+02
1.34E+02
168 Hr
Anneal
70
1.14E+02
1.18E+02
1.30E+02
1.23E+02
1.20E+02
1.17E+02
1.43E+02
1.16E+02
1.34E+02
1.36E+02
1.12E+02
1.36E+02
1.21E+02
6.06E+00
1.38E+02
1.04E+02
1.21E+02
6.49E+00
1.39E+02
1.04E+02
1.21E+02
6.26E+00
1.38E+02
1.04E+02
1.21E+02
5.94E+00
1.37E+02
1.05E+02
1.29E+02
1.15E+01
1.61E+02
9.76E+01
8.20E+01
PASS
1.30E+02
1.26E+01
1.64E+02
9.51E+01
8.20E+01
PASS
1.31E+02
1.49E+01
1.72E+02
9.02E+01
8.20E+01
PASS
1.29E+02
1.20E+01
1.62E+02
9.63E+01
8.20E+01
PASS
10
1.14E+02
1.18E+02
1.32E+02
1.23E+02
1.20E+02
1.17E+02
1.39E+02
1.17E+02
1.34E+02
1.38E+02
1.12E+02
1.35E+02
Total Dose (krad(Si))
20
30
1.14E+02 1.14E+02
1.18E+02 1.18E+02
1.30E+02 1.30E+02
1.24E+02 1.23E+02
1.20E+02 1.20E+02
1.17E+02 1.17E+02
1.42E+02 1.42E+02
1.16E+02 1.17E+02
1.33E+02 1.34E+02
1.37E+02 1.36E+02
1.12E+02 1.12E+02
1.34E+02 1.34E+02
1.21E+02
6.75E+00
1.40E+02
1.03E+02
1.21E+02
5.97E+00
1.37E+02
1.05E+02
1.29E+02
1.12E+01
1.60E+02
9.82E+01
8.20E+01
PASS
1.29E+02
1.17E+01
1.61E+02
9.66E+01
8.20E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
362
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V
1.40E+02
1.20E+02
1.00E+02
8.00E+01
6.00E+01
4.00E+01
2.00E+01
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.176. Plot of PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are
the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds
are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
363
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.176. Raw data for PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
PSRR Match2 2 to 3 (dB)
@ VS=+4.5V to +12V
Device
557
563
564
567
569
570
571
572
573
574
584
585
0
1.40E+02
1.18E+02
1.17E+02
1.24E+02
1.21E+02
1.16E+02
1.14E+02
1.31E+02
1.34E+02
1.06E+02
1.34E+02
1.15E+02
Biased Statistics
Average Biased
1.24E+02
Std Dev Biased
9.36E+00
Ps90%/90% (+KTL) Biased
1.49E+02
Ps90%/90% (-KTL) Biased
9.81E+01
Un-Biased Statistics
Average Un-Biased
1.20E+02
Std Dev Un-Biased
1.19E+01
Ps90%/90% (+KTL) Un-Biased 1.53E+02
Ps90%/90% (-KTL) Un-Biased
8.71E+01
Specification MIN
8.20E+01
Status
PASS
50
1.60E+02
1.18E+02
1.17E+02
1.24E+02
1.22E+02
1.16E+02
1.14E+02
1.32E+02
1.36E+02
1.06E+02
1.34E+02
1.15E+02
24 Hr
Anneal
60
1.45E+02
1.18E+02
1.17E+02
1.24E+02
1.22E+02
1.16E+02
1.14E+02
1.33E+02
1.34E+02
1.06E+02
1.34E+02
1.15E+02
168 Hr
Anneal
70
1.58E+02
1.18E+02
1.17E+02
1.24E+02
1.22E+02
1.16E+02
1.14E+02
1.33E+02
1.36E+02
1.06E+02
1.33E+02
1.15E+02
1.28E+02
1.78E+01
1.77E+02
7.94E+01
1.28E+02
1.81E+01
1.78E+02
7.86E+01
1.25E+02
1.15E+01
1.57E+02
9.39E+01
1.28E+02
1.72E+01
1.75E+02
8.06E+01
1.21E+02
1.28E+01
1.56E+02
8.55E+01
8.20E+01
PASS
1.21E+02
1.28E+01
1.56E+02
8.56E+01
8.20E+01
PASS
1.20E+02
1.24E+01
1.54E+02
8.64E+01
8.20E+01
PASS
1.21E+02
1.31E+01
1.57E+02
8.51E+01
8.20E+01
PASS
10
1.45E+02
1.19E+02
1.17E+02
1.25E+02
1.21E+02
1.15E+02
1.14E+02
1.32E+02
1.36E+02
1.06E+02
1.33E+02
1.15E+02
Total Dose (krad(Si))
20
30
1.48E+02 1.59E+02
1.18E+02 1.18E+02
1.17E+02 1.17E+02
1.25E+02 1.25E+02
1.22E+02 1.22E+02
1.15E+02 1.16E+02
1.14E+02 1.14E+02
1.33E+02 1.34E+02
1.34E+02 1.34E+02
1.06E+02 1.06E+02
1.32E+02 1.32E+02
1.15E+02 1.15E+02
1.25E+02
1.16E+01
1.57E+02
9.35E+01
1.26E+02
1.26E+01
1.60E+02
9.11E+01
1.20E+02
1.27E+01
1.55E+02
8.55E+01
8.20E+01
PASS
1.20E+02
1.26E+01
1.55E+02
8.59E+01
8.20E+01
PASS
An ISO 9001:2008 and DSCC Certified Company
364
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Ps90%/90% (+KTL) Biased
+Short-Circuit Current2 1 5V (A) @ VS=+5V
0.00E+00
-5.00E-03
-1.00E-02
-1.50E-02
-2.00E-02
-2.50E-02
-3.00E-02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.177. Plot of +Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
365
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.177. Raw data for +Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
+Short-Circuit Current2 1 5V (A)
@ VS=+5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-2.65E-02
-2.43E-02
-2.37E-02
-2.38E-02
-2.47E-02
-2.44E-02
-2.46E-02
-2.45E-02
-2.39E-02
-2.52E-02
-2.61E-02
-2.62E-02
Total Dose (krad(Si))
20
30
-2.62E-02 -2.61E-02
-2.40E-02 -2.40E-02
-2.34E-02 -2.33E-02
-2.35E-02 -2.34E-02
-2.43E-02 -2.42E-02
-2.42E-02 -2.41E-02
-2.45E-02 -2.43E-02
-2.43E-02 -2.42E-02
-2.37E-02 -2.36E-02
-2.50E-02 -2.49E-02
-2.61E-02 -2.61E-02
-2.62E-02 -2.62E-02
10
-2.64E-02
-2.42E-02
-2.35E-02
-2.36E-02
-2.45E-02
-2.44E-02
-2.46E-02
-2.44E-02
-2.38E-02
-2.51E-02
-2.61E-02
-2.62E-02
50
-2.58E-02
-2.37E-02
-2.31E-02
-2.32E-02
-2.40E-02
-2.39E-02
-2.41E-02
-2.39E-02
-2.34E-02
-2.46E-02
-2.61E-02
-2.62E-02
24 Hr
Anneal
60
-2.58E-02
-2.37E-02
-2.31E-02
-2.32E-02
-2.40E-02
-2.39E-02
-2.41E-02
-2.39E-02
-2.34E-02
-2.46E-02
-2.61E-02
-2.62E-02
168 Hr
Anneal
70
-2.60E-02
-2.39E-02
-2.33E-02
-2.34E-02
-2.42E-02
-2.41E-02
-2.42E-02
-2.41E-02
-2.35E-02
-2.48E-02
-2.61E-02
-2.62E-02
-2.46E-02 -2.44E-02 -2.43E-02 -2.42E-02 -2.40E-02 -2.40E-02 -2.42E-02
1.13E-03 1.16E-03 1.15E-03 1.14E-03 1.10E-03 1.10E-03 1.11E-03
-2.15E-02 -2.12E-02 -2.11E-02 -2.11E-02 -2.10E-02 -2.10E-02 -2.11E-02
-2.77E-02 -2.76E-02 -2.74E-02 -2.73E-02 -2.70E-02 -2.70E-02 -2.72E-02
-2.45E-02
4.57E-04
-2.32E-02
-2.58E-02
-1.25E-02
PASS
-2.45E-02
4.64E-04
-2.32E-02
-2.57E-02
-8.00E-03
PASS
-2.43E-02
4.56E-04
-2.31E-02
-2.56E-02
-8.00E-03
PASS
-2.42E-02
4.53E-04
-2.30E-02
-2.55E-02
-8.00E-03
PASS
-2.40E-02
4.41E-04
-2.27E-02
-2.52E-02
-8.00E-03
PASS
An ISO 9001:2008 and DSCC Certified Company
366
-2.40E-02
4.40E-04
-2.28E-02
-2.52E-02
-8.00E-03
PASS
-2.41E-02
4.48E-04
-2.29E-02
-2.54E-02
-8.00E-03
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Ps90%/90% (+KTL) Biased
+Short-Circuit Current2 2 5V (A) @ VS=+5V
0.00E+00
-5.00E-03
-1.00E-02
-1.50E-02
-2.00E-02
-2.50E-02
-3.00E-02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.178. Plot of +Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
367
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.178. Raw data for +Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
+Short-Circuit Current2 2 5V (A)
@ VS=+5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-2.80E-02
-2.38E-02
-2.38E-02
-2.35E-02
-2.51E-02
-2.44E-02
-2.51E-02
-2.62E-02
-2.38E-02
-2.63E-02
-2.44E-02
-2.43E-02
Total Dose (krad(Si))
20
30
-2.77E-02 -2.75E-02
-2.35E-02 -2.35E-02
-2.35E-02 -2.34E-02
-2.32E-02 -2.31E-02
-2.47E-02 -2.46E-02
-2.42E-02 -2.41E-02
-2.49E-02 -2.48E-02
-2.60E-02 -2.58E-02
-2.37E-02 -2.36E-02
-2.61E-02 -2.60E-02
-2.44E-02 -2.44E-02
-2.43E-02 -2.43E-02
10
-2.78E-02
-2.36E-02
-2.36E-02
-2.33E-02
-2.49E-02
-2.44E-02
-2.50E-02
-2.61E-02
-2.38E-02
-2.62E-02
-2.44E-02
-2.43E-02
50
-2.72E-02
-2.32E-02
-2.32E-02
-2.29E-02
-2.44E-02
-2.39E-02
-2.45E-02
-2.55E-02
-2.33E-02
-2.56E-02
-2.44E-02
-2.42E-02
24 Hr
Anneal
60
-2.72E-02
-2.32E-02
-2.32E-02
-2.29E-02
-2.44E-02
-2.39E-02
-2.45E-02
-2.55E-02
-2.33E-02
-2.56E-02
-2.43E-02
-2.42E-02
168 Hr
Anneal
70
-2.75E-02
-2.34E-02
-2.34E-02
-2.31E-02
-2.46E-02
-2.40E-02
-2.47E-02
-2.57E-02
-2.35E-02
-2.58E-02
-2.44E-02
-2.43E-02
-2.48E-02 -2.47E-02 -2.45E-02 -2.44E-02 -2.42E-02 -2.42E-02 -2.44E-02
1.86E-03 1.86E-03 1.86E-03 1.83E-03 1.79E-03 1.79E-03 1.80E-03
-1.97E-02 -1.95E-02 -1.94E-02 -1.94E-02 -1.93E-02 -1.93E-02 -1.95E-02
-2.99E-02 -2.98E-02 -2.96E-02 -2.94E-02 -2.91E-02 -2.91E-02 -2.93E-02
-2.52E-02
1.06E-03
-2.22E-02
-2.81E-02
-1.25E-02
PASS
-2.51E-02
1.07E-03
-2.22E-02
-2.80E-02
-8.00E-03
PASS
-2.50E-02
1.06E-03
-2.21E-02
-2.79E-02
-8.00E-03
PASS
-2.49E-02
1.05E-03
-2.20E-02
-2.77E-02
-8.00E-03
PASS
-2.45E-02
1.03E-03
-2.17E-02
-2.74E-02
-8.00E-03
PASS
An ISO 9001:2008 and DSCC Certified Company
368
-2.45E-02
1.03E-03
-2.17E-02
-2.74E-02
-8.00E-03
PASS
-2.47E-02
1.03E-03
-2.19E-02
-2.76E-02
-8.00E-03
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Ps90%/90% (+KTL) Biased
+Short-Circuit Current2 3 5V (A) @ VS=+5V
0.00E+00
-5.00E-03
-1.00E-02
-1.50E-02
-2.00E-02
-2.50E-02
-3.00E-02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.179. Plot of +Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
369
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.179. Raw data for +Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
+Short-Circuit Current2 3 5V (A)
@ VS=+5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-2.79E-02
-2.36E-02
-2.40E-02
-2.36E-02
-2.52E-02
-2.43E-02
-2.52E-02
-2.62E-02
-2.38E-02
-2.64E-02
-2.42E-02
-2.43E-02
Total Dose (krad(Si))
20
30
-2.76E-02 -2.75E-02
-2.33E-02 -2.32E-02
-2.36E-02 -2.35E-02
-2.32E-02 -2.32E-02
-2.48E-02 -2.47E-02
-2.42E-02 -2.41E-02
-2.51E-02 -2.49E-02
-2.60E-02 -2.59E-02
-2.36E-02 -2.35E-02
-2.63E-02 -2.61E-02
-2.42E-02 -2.43E-02
-2.43E-02 -2.43E-02
10
-2.78E-02
-2.34E-02
-2.38E-02
-2.34E-02
-2.50E-02
-2.43E-02
-2.52E-02
-2.61E-02
-2.37E-02
-2.64E-02
-2.42E-02
-2.43E-02
50
-2.71E-02
-2.30E-02
-2.34E-02
-2.30E-02
-2.45E-02
-2.38E-02
-2.46E-02
-2.56E-02
-2.32E-02
-2.58E-02
-2.42E-02
-2.43E-02
24 Hr
Anneal
60
-2.71E-02
-2.30E-02
-2.33E-02
-2.30E-02
-2.45E-02
-2.38E-02
-2.46E-02
-2.56E-02
-2.32E-02
-2.58E-02
-2.42E-02
-2.42E-02
168 Hr
Anneal
70
-2.74E-02
-2.32E-02
-2.35E-02
-2.32E-02
-2.47E-02
-2.40E-02
-2.48E-02
-2.58E-02
-2.34E-02
-2.60E-02
-2.42E-02
-2.43E-02
-2.48E-02 -2.47E-02 -2.45E-02 -2.44E-02 -2.42E-02 -2.42E-02 -2.44E-02
1.83E-03 1.85E-03 1.83E-03 1.81E-03 1.76E-03 1.76E-03 1.78E-03
-1.98E-02 -1.96E-02 -1.95E-02 -1.95E-02 -1.94E-02 -1.94E-02 -1.95E-02
-2.98E-02 -2.97E-02 -2.95E-02 -2.94E-02 -2.90E-02 -2.90E-02 -2.93E-02
-2.52E-02
1.16E-03
-2.20E-02
-2.84E-02
-1.25E-02
PASS
-2.51E-02
1.16E-03
-2.20E-02
-2.83E-02
-8.00E-03
PASS
-2.50E-02
1.15E-03
-2.19E-02
-2.82E-02
-8.00E-03
PASS
-2.49E-02
1.14E-03
-2.18E-02
-2.80E-02
-8.00E-03
PASS
-2.46E-02
1.12E-03
-2.15E-02
-2.77E-02
-8.00E-03
PASS
An ISO 9001:2008 and DSCC Certified Company
370
-2.46E-02
1.12E-03
-2.15E-02
-2.76E-02
-8.00E-03
PASS
-2.48E-02
1.13E-03
-2.17E-02
-2.79E-02
-8.00E-03
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (+KTL) Un-Biased
Specification MAX
Ps90%/90% (+KTL) Biased
+Short-Circuit Current2 4 5V (A) @ VS=+5V
0.00E+00
-5.00E-03
-1.00E-02
-1.50E-02
-2.00E-02
-2.50E-02
-3.00E-02
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.180. Plot of +Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
371
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.180. Raw data for +Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
+Short-Circuit Current2 4 5V (A)
@ VS=+5V
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MAX
Status
0
-2.63E-02
-2.43E-02
-2.36E-02
-2.38E-02
-2.46E-02
-2.44E-02
-2.46E-02
-2.44E-02
-2.38E-02
-2.52E-02
-2.60E-02
-2.62E-02
Total Dose (krad(Si))
20
30
-2.61E-02 -2.60E-02
-2.40E-02 -2.39E-02
-2.33E-02 -2.32E-02
-2.35E-02 -2.34E-02
-2.42E-02 -2.42E-02
-2.43E-02 -2.42E-02
-2.44E-02 -2.43E-02
-2.43E-02 -2.41E-02
-2.37E-02 -2.36E-02
-2.50E-02 -2.49E-02
-2.61E-02 -2.61E-02
-2.62E-02 -2.62E-02
10
-2.62E-02
-2.42E-02
-2.34E-02
-2.36E-02
-2.44E-02
-2.44E-02
-2.45E-02
-2.44E-02
-2.38E-02
-2.51E-02
-2.61E-02
-2.62E-02
50
-2.57E-02
-2.37E-02
-2.30E-02
-2.32E-02
-2.40E-02
-2.39E-02
-2.40E-02
-2.39E-02
-2.33E-02
-2.46E-02
-2.60E-02
-2.62E-02
24 Hr
Anneal
60
-2.56E-02
-2.37E-02
-2.30E-02
-2.32E-02
-2.40E-02
-2.39E-02
-2.40E-02
-2.39E-02
-2.33E-02
-2.46E-02
-2.60E-02
-2.62E-02
168 Hr
Anneal
70
-2.59E-02
-2.39E-02
-2.32E-02
-2.34E-02
-2.42E-02
-2.41E-02
-2.42E-02
-2.40E-02
-2.35E-02
-2.48E-02
-2.60E-02
-2.62E-02
-2.45E-02 -2.44E-02 -2.42E-02 -2.41E-02 -2.39E-02 -2.39E-02 -2.41E-02
1.09E-03 1.11E-03 1.11E-03 1.09E-03 1.05E-03 1.05E-03 1.07E-03
-2.15E-02 -2.13E-02 -2.12E-02 -2.11E-02 -2.10E-02 -2.10E-02 -2.12E-02
-2.75E-02 -2.74E-02 -2.73E-02 -2.71E-02 -2.68E-02 -2.68E-02 -2.70E-02
-2.45E-02
4.86E-04
-2.32E-02
-2.58E-02
-1.25E-02
PASS
-2.44E-02
4.86E-04
-2.31E-02
-2.58E-02
-8.00E-03
PASS
-2.43E-02
4.86E-04
-2.30E-02
-2.57E-02
-8.00E-03
PASS
-2.42E-02
4.82E-04
-2.29E-02
-2.55E-02
-8.00E-03
PASS
-2.39E-02
4.71E-04
-2.26E-02
-2.52E-02
-8.00E-03
PASS
An ISO 9001:2008 and DSCC Certified Company
372
-2.39E-02
4.67E-04
-2.26E-02
-2.52E-02
-8.00E-03
PASS
-2.41E-02
4.75E-04
-2.28E-02
-2.54E-02
-8.00E-03
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
-Short-Circuit Current2 1 5V (A) @ VS=+5V
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.181. Plot of -Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
373
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.181. Raw data for -Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
-Short-Circuit Current2 1 5V (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V
Device
0
10
20
30
50
60
70
557 5.10E-02 5.11E-02 5.10E-02 5.09E-02 5.12E-02 5.13E-02 5.11E-02
563 4.89E-02 4.90E-02 4.88E-02 4.87E-02 4.89E-02 4.91E-02 4.88E-02
564 4.79E-02 4.77E-02 4.77E-02 4.75E-02 4.77E-02 4.81E-02 4.77E-02
567 4.78E-02 4.75E-02 4.75E-02 4.74E-02 4.77E-02 4.78E-02 4.77E-02
569 4.89E-02 4.87E-02 4.87E-02 4.86E-02 4.89E-02 4.91E-02 4.88E-02
570 4.90E-02 4.89E-02 4.88E-02 4.87E-02 4.92E-02 4.91E-02 4.90E-02
571 4.89E-02 4.90E-02 4.88E-02 4.87E-02 4.90E-02 4.90E-02 4.90E-02
572 4.79E-02 4.82E-02 4.78E-02 4.78E-02 4.82E-02 4.83E-02 4.81E-02
573 4.81E-02 4.83E-02 4.80E-02 4.79E-02 4.83E-02 4.83E-02 4.82E-02
574 4.98E-02 4.98E-02 4.95E-02 4.94E-02 4.97E-02 4.99E-02 4.96E-02
584 5.10E-02 5.09E-02 5.08E-02 5.07E-02 5.12E-02 5.12E-02 5.10E-02
585 5.04E-02 5.02E-02 5.00E-02 5.02E-02 5.06E-02 5.08E-02 5.04E-02
Biased Statistics
Average Biased
4.89E-02 4.88E-02 4.87E-02 4.86E-02 4.89E-02 4.91E-02 4.88E-02
Std Dev Biased
1.28E-03 1.43E-03 1.39E-03 1.38E-03 1.42E-03 1.39E-03 1.38E-03
Ps90%/90% (+KTL) Biased
5.24E-02 5.27E-02 5.25E-02 5.24E-02 5.28E-02 5.29E-02 5.26E-02
Ps90%/90% (-KTL) Biased
4.54E-02 4.49E-02 4.49E-02 4.48E-02 4.50E-02 4.53E-02 4.50E-02
Un-Biased Statistics
Average Un-Biased
4.87E-02 4.88E-02 4.86E-02 4.85E-02 4.89E-02 4.89E-02 4.88E-02
Std Dev Un-Biased
7.33E-04 6.39E-04 6.76E-04 6.44E-04 6.59E-04 6.68E-04 6.54E-04
Ps90%/90% (+KTL) Un-Biased
5.08E-02 5.06E-02 5.04E-02 5.03E-02 5.07E-02 5.07E-02 5.06E-02
Ps90%/90% (-KTL) Un-Biased
4.67E-02 4.71E-02 4.67E-02 4.67E-02 4.71E-02 4.71E-02 4.70E-02
Specification MIN
1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
374
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
-Short-Circuit Current2 2 5V (A) @ VS=+5V
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.182. Plot of -Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
375
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.182. Raw data for -Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
-Short-Circuit Current2 2 5V (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V
Device
0
10
20
30
50
60
70
557 5.16E-02 5.16E-02 5.16E-02 5.15E-02 5.18E-02 5.19E-02 5.17E-02
563 4.70E-02 4.71E-02 4.69E-02 4.68E-02 4.70E-02 4.72E-02 4.69E-02
564 4.73E-02 4.71E-02 4.70E-02 4.68E-02 4.71E-02 4.74E-02 4.71E-02
567 4.73E-02 4.71E-02 4.70E-02 4.70E-02 4.73E-02 4.74E-02 4.73E-02
569 4.88E-02 4.85E-02 4.86E-02 4.85E-02 4.89E-02 4.89E-02 4.87E-02
570 4.80E-02 4.79E-02 4.78E-02 4.77E-02 4.82E-02 4.82E-02 4.80E-02
571 4.90E-02 4.91E-02 4.89E-02 4.88E-02 4.91E-02 4.92E-02 4.92E-02
572 4.99E-02 5.01E-02 4.99E-02 4.98E-02 5.01E-02 5.02E-02 5.01E-02
573 4.77E-02 4.79E-02 4.77E-02 4.75E-02 4.78E-02 4.79E-02 4.78E-02
574 5.04E-02 5.04E-02 5.01E-02 5.00E-02 5.04E-02 5.05E-02 5.03E-02
584 4.79E-02 4.78E-02 4.78E-02 4.77E-02 4.82E-02 4.82E-02 4.79E-02
585 4.82E-02 4.79E-02 4.78E-02 4.79E-02 4.83E-02 4.85E-02 4.82E-02
Biased Statistics
Average Biased
4.84E-02 4.83E-02 4.82E-02 4.81E-02 4.84E-02 4.86E-02 4.83E-02
Std Dev Biased
1.93E-03 1.98E-03 2.00E-03 2.00E-03 2.04E-03 2.00E-03 2.00E-03
Ps90%/90% (+KTL) Biased
5.37E-02 5.37E-02 5.37E-02 5.36E-02 5.40E-02 5.41E-02 5.38E-02
Ps90%/90% (-KTL) Biased
4.31E-02 4.29E-02 4.27E-02 4.26E-02 4.28E-02 4.31E-02 4.28E-02
Un-Biased Statistics
Average Un-Biased
4.90E-02 4.91E-02 4.89E-02 4.88E-02 4.91E-02 4.92E-02 4.91E-02
Std Dev Un-Biased
1.17E-03 1.15E-03 1.14E-03 1.13E-03 1.13E-03 1.17E-03 1.15E-03
Ps90%/90% (+KTL) Un-Biased
5.22E-02 5.22E-02 5.20E-02 5.19E-02 5.22E-02 5.24E-02 5.22E-02
Ps90%/90% (-KTL) Un-Biased
4.58E-02 4.59E-02 4.58E-02 4.56E-02 4.60E-02 4.60E-02 4.59E-02
Specification MIN
1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
376
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
-Short-Circuit Current2 3 5V (A) @ VS=+5V
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.183. Plot of -Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
377
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.183. Raw data for -Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
-Short-Circuit Current2 3 5V (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V
Device
0
10
20
30
50
60
70
557 5.23E-02 5.24E-02 5.23E-02 5.22E-02 5.26E-02 5.27E-02 5.24E-02
563 4.77E-02 4.78E-02 4.76E-02 4.74E-02 4.77E-02 4.79E-02 4.76E-02
564 4.79E-02 4.77E-02 4.77E-02 4.75E-02 4.77E-02 4.81E-02 4.77E-02
567 4.80E-02 4.77E-02 4.77E-02 4.77E-02 4.80E-02 4.81E-02 4.79E-02
569 4.94E-02 4.91E-02 4.93E-02 4.91E-02 4.95E-02 4.96E-02 4.93E-02
570 4.88E-02 4.88E-02 4.87E-02 4.85E-02 4.90E-02 4.90E-02 4.89E-02
571 5.00E-02 5.01E-02 4.99E-02 4.98E-02 5.01E-02 5.01E-02 5.00E-02
572 5.07E-02 5.10E-02 5.06E-02 5.06E-02 5.09E-02 5.11E-02 5.08E-02
573 4.84E-02 4.86E-02 4.83E-02 4.82E-02 4.86E-02 4.86E-02 4.84E-02
574 5.12E-02 5.12E-02 5.10E-02 5.09E-02 5.12E-02 5.14E-02 5.11E-02
584 4.87E-02 4.85E-02 4.85E-02 4.84E-02 4.89E-02 4.89E-02 4.87E-02
585 4.89E-02 4.87E-02 4.85E-02 4.87E-02 4.90E-02 4.93E-02 4.89E-02
Biased Statistics
Average Biased
4.90E-02 4.90E-02 4.89E-02 4.88E-02 4.91E-02 4.93E-02 4.90E-02
Std Dev Biased
1.94E-03 2.03E-03 2.03E-03 2.02E-03 2.07E-03 2.02E-03 2.03E-03
Ps90%/90% (+KTL) Biased
5.44E-02 5.45E-02 5.45E-02 5.43E-02 5.48E-02 5.48E-02 5.46E-02
Ps90%/90% (-KTL) Biased
4.37E-02 4.34E-02 4.33E-02 4.32E-02 4.34E-02 4.37E-02 4.34E-02
Un-Biased Statistics
Average Un-Biased
4.98E-02 4.99E-02 4.97E-02 4.96E-02 5.00E-02 5.00E-02 4.99E-02
Std Dev Un-Biased
1.20E-03 1.22E-03 1.18E-03 1.19E-03 1.16E-03 1.22E-03 1.18E-03
Ps90%/90% (+KTL) Un-Biased
5.31E-02 5.33E-02 5.29E-02 5.28E-02 5.31E-02 5.34E-02 5.31E-02
Ps90%/90% (-KTL) Un-Biased
4.65E-02 4.66E-02 4.65E-02 4.63E-02 4.68E-02 4.67E-02 4.66E-02
Specification MIN
1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
378
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Ps90%/90% (-KTL) Biased
-Short-Circuit Current2 4 5V (A) @ VS=+5V
6.00E-02
5.00E-02
4.00E-02
3.00E-02
2.00E-02
1.00E-02
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.184. Plot of -Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose. The solid diamonds are the
average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are
the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines
(solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples
irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after
application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the
pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test
plan.
An ISO 9001:2008 and DSCC Certified Company
379
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.184. Raw data for -Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose, including the
statistical analysis, specification and the status of the testing (pass/fail).
24 Hr
168 Hr
-Short-Circuit Current2 4 5V (A)
Total Dose (krad(Si))
Anneal
Anneal
@ VS=+5V
Device
0
10
20
30
50
60
70
557 5.05E-02 5.06E-02 5.05E-02 5.04E-02 5.07E-02 5.08E-02 5.06E-02
563 4.84E-02 4.85E-02 4.83E-02 4.82E-02 4.84E-02 4.87E-02 4.83E-02
564 4.75E-02 4.72E-02 4.72E-02 4.70E-02 4.72E-02 4.75E-02 4.73E-02
567 4.71E-02 4.69E-02 4.68E-02 4.68E-02 4.71E-02 4.72E-02 4.71E-02
569 4.84E-02 4.82E-02 4.82E-02 4.81E-02 4.84E-02 4.85E-02 4.83E-02
570 4.84E-02 4.83E-02 4.83E-02 4.81E-02 4.86E-02 4.85E-02 4.84E-02
571 4.83E-02 4.84E-02 4.82E-02 4.81E-02 4.84E-02 4.85E-02 4.84E-02
572 4.76E-02 4.78E-02 4.75E-02 4.74E-02 4.77E-02 4.79E-02 4.77E-02
573 4.76E-02 4.78E-02 4.75E-02 4.74E-02 4.77E-02 4.78E-02 4.77E-02
574 4.92E-02 4.91E-02 4.89E-02 4.88E-02 4.92E-02 4.93E-02 4.91E-02
584 5.03E-02 5.01E-02 5.01E-02 4.99E-02 5.05E-02 5.05E-02 5.02E-02
585 4.96E-02 4.94E-02 4.93E-02 4.94E-02 4.98E-02 5.01E-02 4.96E-02
Biased Statistics
Average Biased
4.84E-02 4.83E-02 4.82E-02 4.81E-02 4.84E-02 4.86E-02 4.83E-02
Std Dev Biased
1.32E-03 1.46E-03 1.42E-03 1.42E-03 1.44E-03 1.42E-03 1.41E-03
Ps90%/90% (+KTL) Biased
5.20E-02 5.23E-02 5.21E-02 5.20E-02 5.23E-02 5.25E-02 5.21E-02
Ps90%/90% (-KTL) Biased
4.48E-02 4.43E-02 4.43E-02 4.42E-02 4.44E-02 4.47E-02 4.44E-02
Un-Biased Statistics
Average Un-Biased
4.82E-02 4.83E-02 4.81E-02 4.79E-02 4.83E-02 4.84E-02 4.83E-02
Std Dev Un-Biased
6.52E-04 5.48E-04 5.97E-04 5.77E-04 5.97E-04 6.25E-04 6.07E-04
Ps90%/90% (+KTL) Un-Biased
5.00E-02 4.98E-02 4.97E-02 4.95E-02 5.00E-02 5.01E-02 4.99E-02
Ps90%/90% (-KTL) Un-Biased
4.64E-02 4.68E-02 4.65E-02 4.64E-02 4.67E-02 4.67E-02 4.66E-02
Specification MIN
1.25E-02 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03 8.00E-03
Status
PASS
PASS
PASS
PASS
PASS
PASS
PASS
An ISO 9001:2008 and DSCC Certified Company
380
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.80E+01
Gain-Bandwidth Product_1 15V (MHz)
@ VS=+/-15V, f=100kHz
1.60E+01
1.40E+01
1.20E+01
1.00E+01
8.00E+00
6.00E+00
4.00E+00
2.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.185. Plot of Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
381
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.185. Raw data for Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Gain-Bandwidth Product_1 15V (MHz)
@ VS=+/-15V, f=100kHz
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
1.61E+01
1.64E+01
1.66E+01
1.67E+01
1.65E+01
1.66E+01
1.61E+01
1.65E+01
1.63E+01
1.63E+01
1.57E+01
1.62E+01
10
1.61E+01
1.64E+01
1.66E+01
1.67E+01
1.65E+01
1.66E+01
1.61E+01
1.66E+01
1.63E+01
1.63E+01
1.57E+01
1.62E+01
Total Dose (krad(Si))
20
30
1.61E+01 1.61E+01
1.64E+01 1.64E+01
1.66E+01 1.65E+01
1.67E+01 1.66E+01
1.64E+01 1.64E+01
1.66E+01 1.66E+01
1.61E+01 1.60E+01
1.65E+01 1.65E+01
1.63E+01 1.63E+01
1.63E+01 1.63E+01
1.57E+01 1.57E+01
1.62E+01 1.62E+01
50
1.61E+01
1.63E+01
1.65E+01
1.66E+01
1.64E+01
1.65E+01
1.60E+01
1.65E+01
1.62E+01
1.62E+01
1.57E+01
1.62E+01
24 Hr
Anneal
60
1.61E+01
1.63E+01
1.65E+01
1.66E+01
1.64E+01
1.65E+01
1.60E+01
1.64E+01
1.62E+01
1.63E+01
1.57E+01
1.62E+01
168 Hr
Anneal
70
1.61E+01
1.63E+01
1.65E+01
1.66E+01
1.64E+01
1.65E+01
1.60E+01
1.64E+01
1.62E+01
1.63E+01
1.57E+01
1.62E+01
1.65E+01 1.65E+01 1.64E+01 1.64E+01 1.64E+01 1.64E+01 1.64E+01
2.26E-01 2.16E-01 2.15E-01 1.89E-01 2.05E-01 2.03E-01 2.14E-01
1.71E+01 1.71E+01 1.70E+01 1.69E+01 1.69E+01 1.69E+01 1.70E+01
1.58E+01 1.59E+01 1.58E+01 1.59E+01 1.58E+01 1.58E+01 1.58E+01
1.64E+01
2.00E-01
1.69E+01
1.58E+01
6.80E+00
PASS
1.64E+01
2.06E-01
1.69E+01
1.58E+01
4.50E+00
PASS
1.64E+01
1.98E-01
1.69E+01
1.58E+01
4.50E+00
PASS
1.63E+01
2.08E-01
1.69E+01
1.57E+01
4.50E+00
PASS
1.63E+01
1.95E-01
1.68E+01
1.57E+01
4.50E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
382
1.63E+01
1.86E-01
1.68E+01
1.58E+01
4.50E+00
PASS
1.63E+01
1.97E-01
1.68E+01
1.57E+01
4.50E+00
PASS
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.80E+01
Gain-Bandwidth Product_2 15V (MHz)
@ VS=+/-15V, f=100kHz
1.60E+01
1.40E+01
1.20E+01
1.00E+01
8.00E+00
6.00E+00
4.00E+00
2.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.186. Plot of Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
383
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.186. Raw data for Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Gain-Bandwidth Product_2 15V (MHz)
@ VS=+/-15V, f=100kHz
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
1.59E+01
1.68E+01
1.65E+01
1.64E+01
1.61E+01
1.64E+01
1.61E+01
1.62E+01
1.59E+01
1.61E+01
1.66E+01
1.65E+01
10
1.59E+01
1.68E+01
1.64E+01
1.63E+01
1.61E+01
1.64E+01
1.62E+01
1.62E+01
1.59E+01
1.61E+01
1.66E+01
1.65E+01
Total Dose (krad(Si))
20
30
1.59E+01 1.58E+01
1.68E+01 1.68E+01
1.64E+01 1.64E+01
1.63E+01 1.63E+01
1.61E+01 1.60E+01
1.64E+01 1.63E+01
1.61E+01 1.61E+01
1.62E+01 1.61E+01
1.58E+01 1.58E+01
1.61E+01 1.61E+01
1.66E+01 1.66E+01
1.65E+01 1.65E+01
50
1.58E+01
1.67E+01
1.63E+01
1.63E+01
1.60E+01
1.63E+01
1.61E+01
1.61E+01
1.58E+01
1.60E+01
1.65E+01
1.65E+01
24 Hr
Anneal
60
1.58E+01
1.67E+01
1.64E+01
1.63E+01
1.60E+01
1.63E+01
1.61E+01
1.61E+01
1.57E+01
1.60E+01
1.66E+01
1.66E+01
168 Hr
Anneal
70
1.58E+01
1.67E+01
1.64E+01
1.62E+01
1.60E+01
1.63E+01
1.60E+01
1.61E+01
1.58E+01
1.60E+01
1.66E+01
1.65E+01
1.63E+01 1.63E+01 1.63E+01 1.63E+01 1.62E+01 1.62E+01 1.62E+01
3.59E-01 3.71E-01 3.48E-01 3.50E-01 3.50E-01 3.52E-01 3.46E-01
1.73E+01 1.73E+01 1.72E+01 1.72E+01 1.72E+01 1.72E+01 1.72E+01
1.54E+01 1.53E+01 1.53E+01 1.53E+01 1.53E+01 1.53E+01 1.53E+01
1.61E+01
1.69E-01
1.66E+01
1.57E+01
6.80E+00
PASS
1.61E+01
1.85E-01
1.67E+01
1.56E+01
4.50E+00
PASS
1.61E+01
1.98E-01
1.67E+01
1.56E+01
4.50E+00
PASS
1.61E+01
1.89E-01
1.66E+01
1.56E+01
4.50E+00
PASS
1.61E+01
1.99E-01
1.66E+01
1.55E+01
4.50E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
384
1.61E+01
2.11E-01
1.66E+01
1.55E+01
4.50E+00
PASS
1.61E+01
1.93E-01
1.66E+01
1.55E+01
4.50E+00
PASS
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.80E+01
Gain-Bandwidth Product_3 15V (MHz)
@ VS=+/-15V, f=100kHz
1.60E+01
1.40E+01
1.20E+01
1.00E+01
8.00E+00
6.00E+00
4.00E+00
2.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.187. Plot of Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
385
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.187. Raw data for Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Gain-Bandwidth Product_3 15V (MHz)
@ VS=+/-15V, f=100kHz
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
1.58E+01
1.68E+01
1.65E+01
1.64E+01
1.60E+01
1.65E+01
1.61E+01
1.62E+01
1.58E+01
1.62E+01
1.64E+01
1.65E+01
10
1.58E+01
1.68E+01
1.65E+01
1.63E+01
1.59E+01
1.65E+01
1.61E+01
1.62E+01
1.58E+01
1.62E+01
1.64E+01
1.65E+01
Total Dose (krad(Si))
20
30
1.58E+01 1.58E+01
1.67E+01 1.67E+01
1.64E+01 1.64E+01
1.63E+01 1.63E+01
1.59E+01 1.59E+01
1.64E+01 1.64E+01
1.61E+01 1.60E+01
1.61E+01 1.61E+01
1.58E+01 1.58E+01
1.61E+01 1.61E+01
1.64E+01 1.64E+01
1.65E+01 1.65E+01
50
1.58E+01
1.67E+01
1.64E+01
1.63E+01
1.58E+01
1.64E+01
1.60E+01
1.61E+01
1.57E+01
1.61E+01
1.64E+01
1.65E+01
24 Hr
Anneal
60
1.58E+01
1.67E+01
1.64E+01
1.63E+01
1.59E+01
1.64E+01
1.60E+01
1.61E+01
1.58E+01
1.61E+01
1.64E+01
1.65E+01
168 Hr
Anneal
70
1.58E+01
1.67E+01
1.64E+01
1.63E+01
1.59E+01
1.64E+01
1.60E+01
1.61E+01
1.58E+01
1.61E+01
1.64E+01
1.65E+01
1.63E+01 1.63E+01 1.62E+01 1.62E+01 1.62E+01 1.62E+01 1.62E+01
3.84E-01 3.83E-01 3.75E-01 3.74E-01 3.69E-01 3.85E-01 3.78E-01
1.73E+01 1.73E+01 1.73E+01 1.72E+01 1.72E+01 1.72E+01 1.72E+01
1.52E+01 1.52E+01 1.52E+01 1.52E+01 1.52E+01 1.51E+01 1.51E+01
1.61E+01
2.34E-01
1.68E+01
1.55E+01
6.80E+00
PASS
1.61E+01
2.22E-01
1.68E+01
1.55E+01
4.50E+00
PASS
1.61E+01
2.23E-01
1.67E+01
1.55E+01
4.50E+00
PASS
1.61E+01
2.42E-01
1.67E+01
1.54E+01
4.50E+00
PASS
1.61E+01
2.53E-01
1.67E+01
1.54E+01
4.50E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
386
1.61E+01
2.25E-01
1.67E+01
1.55E+01
4.50E+00
PASS
1.61E+01
2.17E-01
1.66E+01
1.55E+01
4.50E+00
PASS
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
1.80E+01
Gain-Bandwidth Product_4 15V (MHz)
@ VS=+/-15V, f=100kHz
1.60E+01
1.40E+01
1.20E+01
1.00E+01
8.00E+00
6.00E+00
4.00E+00
2.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.188. Plot of Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose. The
solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while
the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
387
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.188. Raw data for Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
Gain-Bandwidth Product_4 15V (MHz)
@ VS=+/-15V, f=100kHz
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
1.60E+01
1.65E+01
1.65E+01
1.67E+01
1.65E+01
1.65E+01
1.62E+01
1.64E+01
1.64E+01
1.64E+01
1.57E+01
1.62E+01
10
1.60E+01
1.64E+01
1.65E+01
1.66E+01
1.65E+01
1.65E+01
1.62E+01
1.64E+01
1.64E+01
1.63E+01
1.57E+01
1.62E+01
Total Dose (krad(Si))
20
30
1.60E+01 1.60E+01
1.64E+01 1.64E+01
1.64E+01 1.64E+01
1.66E+01 1.66E+01
1.65E+01 1.65E+01
1.65E+01 1.65E+01
1.61E+01 1.61E+01
1.64E+01 1.63E+01
1.64E+01 1.63E+01
1.63E+01 1.63E+01
1.57E+01 1.57E+01
1.61E+01 1.61E+01
50
1.59E+01
1.63E+01
1.64E+01
1.66E+01
1.64E+01
1.65E+01
1.61E+01
1.63E+01
1.63E+01
1.63E+01
1.57E+01
1.62E+01
24 Hr
Anneal
60
1.60E+01
1.63E+01
1.64E+01
1.65E+01
1.64E+01
1.64E+01
1.61E+01
1.63E+01
1.63E+01
1.62E+01
1.57E+01
1.62E+01
168 Hr
Anneal
70
1.60E+01
1.63E+01
1.64E+01
1.66E+01
1.64E+01
1.64E+01
1.61E+01
1.63E+01
1.63E+01
1.63E+01
1.57E+01
1.62E+01
1.64E+01 1.64E+01 1.64E+01 1.64E+01 1.63E+01 1.63E+01 1.63E+01
2.37E-01 2.29E-01 2.25E-01 2.27E-01 2.27E-01 2.11E-01 2.27E-01
1.71E+01 1.70E+01 1.70E+01 1.70E+01 1.69E+01 1.69E+01 1.69E+01
1.58E+01 1.58E+01 1.58E+01 1.57E+01 1.57E+01 1.57E+01 1.57E+01
1.64E+01
1.16E-01
1.67E+01
1.61E+01
6.80E+00
PASS
1.64E+01
1.18E-01
1.67E+01
1.60E+01
4.50E+00
PASS
1.63E+01
1.36E-01
1.67E+01
1.60E+01
4.50E+00
PASS
1.63E+01
1.25E-01
1.66E+01
1.60E+01
4.50E+00
PASS
1.63E+01
1.45E-01
1.67E+01
1.59E+01
4.50E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
388
1.63E+01
1.16E-01
1.66E+01
1.60E+01
4.50E+00
PASS
1.63E+01
1.12E-01
1.66E+01
1.60E+01
4.50E+00
PASS
+Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
8.00E+00
7.00E+00
6.00E+00
5.00E+00
4.00E+00
3.00E+00
2.00E+00
1.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.189. Plot of +Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
389
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.189. Raw data for +Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Slew Rate_1 15V (V/us)
@ VS=+/-15, AV=-1, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
6.83E+00
6.91E+00
6.99E+00
7.08E+00
6.94E+00
6.99E+00
6.78E+00
7.04E+00
6.87E+00
6.87E+00
6.62E+00
6.83E+00
10
6.79E+00
6.89E+00
6.99E+00
7.15E+00
6.95E+00
6.98E+00
6.76E+00
6.97E+00
6.84E+00
6.89E+00
6.65E+00
6.82E+00
Total Dose (krad(Si))
20
30
6.80E+00 6.82E+00
6.89E+00 6.86E+00
6.98E+00 6.97E+00
7.05E+00 7.06E+00
6.91E+00 6.95E+00
6.98E+00 6.95E+00
6.72E+00 6.75E+00
6.97E+00 6.96E+00
6.82E+00 6.82E+00
6.86E+00 6.85E+00
6.63E+00 6.65E+00
6.85E+00 6.82E+00
50
6.76E+00
6.86E+00
6.93E+00
7.00E+00
6.87E+00
6.91E+00
6.67E+00
6.94E+00
6.76E+00
6.82E+00
6.63E+00
6.82E+00
24 Hr
Anneal
60
6.80E+00
6.81E+00
6.88E+00
7.02E+00
6.89E+00
6.92E+00
6.71E+00
6.92E+00
6.81E+00
6.81E+00
6.64E+00
6.80E+00
168 Hr
Anneal
70
6.77E+00
6.87E+00
6.92E+00
7.02E+00
6.89E+00
6.92E+00
6.70E+00
6.97E+00
6.80E+00
6.81E+00
6.65E+00
6.80E+00
6.95E+00 6.95E+00 6.93E+00 6.93E+00 6.88E+00 6.88E+00 6.89E+00
9.30E-02 1.33E-01 9.45E-02 9.47E-02 8.91E-02 8.80E-02 9.02E-02
7.21E+00 7.32E+00 7.19E+00 7.19E+00 7.13E+00 7.12E+00 7.14E+00
6.69E+00 6.59E+00 6.67E+00 6.67E+00 6.64E+00 6.64E+00 6.65E+00
6.91E+00
1.04E-01
7.20E+00
6.62E+00
3.50E+00
PASS
6.89E+00
9.20E-02
7.14E+00
6.64E+00
3.00E+00
PASS
6.87E+00
1.09E-01
7.17E+00
6.57E+00
3.00E+00
PASS
6.87E+00
8.91E-02
7.11E+00
6.62E+00
3.00E+00
PASS
6.82E+00
1.10E-01
7.12E+00
6.52E+00
3.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
390
6.83E+00
8.85E-02
7.08E+00
6.59E+00
3.00E+00
PASS
6.84E+00
1.07E-01
7.13E+00
6.55E+00
3.00E+00
PASS
+Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
8.00E+00
7.00E+00
6.00E+00
5.00E+00
4.00E+00
3.00E+00
2.00E+00
1.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.190. Plot of +Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
391
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.190. Raw data for +Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Slew Rate_2 15V (V/us)
@ VS=+/-15, AV=-1, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
6.96E+00
7.59E+00
7.16E+00
7.09E+00
7.03E+00
7.09E+00
6.97E+00
7.02E+00
6.87E+00
7.01E+00
7.30E+00
7.26E+00
10
6.96E+00
7.53E+00
7.17E+00
7.14E+00
7.03E+00
7.08E+00
6.97E+00
7.03E+00
6.83E+00
6.96E+00
7.35E+00
7.24E+00
Total Dose (krad(Si))
20
30
6.98E+00 6.97E+00
7.55E+00 7.54E+00
7.09E+00 7.11E+00
7.09E+00 7.14E+00
7.00E+00 6.99E+00
7.02E+00 7.02E+00
6.96E+00 6.96E+00
7.03E+00 7.01E+00
6.80E+00 6.81E+00
6.97E+00 6.97E+00
7.36E+00 7.30E+00
7.29E+00 7.26E+00
50
6.91E+00
7.45E+00
7.08E+00
7.10E+00
6.95E+00
7.00E+00
6.92E+00
6.98E+00
6.79E+00
6.90E+00
7.31E+00
7.26E+00
24 Hr
Anneal
60
6.90E+00
7.50E+00
7.07E+00
7.05E+00
6.93E+00
6.98E+00
6.90E+00
7.00E+00
6.81E+00
6.95E+00
7.30E+00
7.22E+00
168 Hr
Anneal
70
6.91E+00
7.46E+00
7.08E+00
7.10E+00
6.95E+00
7.00E+00
6.93E+00
6.96E+00
6.79E+00
6.95E+00
7.34E+00
7.26E+00
7.17E+00 7.17E+00 7.14E+00 7.15E+00 7.10E+00 7.09E+00 7.10E+00
2.48E-01 2.20E-01 2.34E-01 2.30E-01 2.13E-01 2.41E-01 2.17E-01
7.85E+00 7.77E+00 7.78E+00 7.78E+00 7.68E+00 7.75E+00 7.70E+00
6.49E+00 6.56E+00 6.50E+00 6.52E+00 6.51E+00 6.43E+00 6.50E+00
6.99E+00
8.07E-02
7.21E+00
6.77E+00
3.50E+00
PASS
6.97E+00
9.40E-02
7.23E+00
6.72E+00
3.00E+00
PASS
6.96E+00
9.24E-02
7.21E+00
6.70E+00
3.00E+00
PASS
6.95E+00
8.44E-02
7.19E+00
6.72E+00
3.00E+00
PASS
6.92E+00
8.26E-02
7.14E+00
6.69E+00
3.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
392
6.93E+00
7.60E-02
7.14E+00
6.72E+00
3.00E+00
PASS
6.93E+00
8.02E-02
7.15E+00
6.71E+00
3.00E+00
PASS
+Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
8.00E+00
7.00E+00
6.00E+00
5.00E+00
4.00E+00
3.00E+00
2.00E+00
1.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.191. Plot of +Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
393
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.191. Raw data for +Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Slew Rate_3 15V (V/us)
@ VS=+/-15, AV=-1, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
6.70E+00
7.18E+00
7.06E+00
7.00E+00
6.72E+00
7.02E+00
6.82E+00
6.80E+00
6.67E+00
6.83E+00
6.97E+00
6.94E+00
10
6.69E+00
7.09E+00
7.03E+00
6.98E+00
6.73E+00
7.00E+00
6.78E+00
6.82E+00
6.64E+00
6.82E+00
6.97E+00
6.93E+00
Total Dose (krad(Si))
20
30
6.65E+00 6.70E+00
7.15E+00 7.11E+00
7.05E+00 7.02E+00
6.98E+00 6.95E+00
6.74E+00 6.72E+00
6.97E+00 7.00E+00
6.75E+00 6.77E+00
6.81E+00 6.77E+00
6.61E+00 6.59E+00
6.83E+00 6.84E+00
7.01E+00 6.97E+00
6.99E+00 6.95E+00
50
6.67E+00
7.08E+00
6.99E+00
6.91E+00
6.71E+00
6.91E+00
6.71E+00
6.75E+00
6.58E+00
6.76E+00
6.94E+00
6.99E+00
24 Hr
Anneal
60
6.65E+00
7.06E+00
6.99E+00
6.90E+00
6.68E+00
6.92E+00
6.69E+00
6.75E+00
6.57E+00
6.78E+00
6.92E+00
6.93E+00
168 Hr
Anneal
70
6.66E+00
7.09E+00
7.00E+00
6.92E+00
6.70E+00
6.96E+00
6.69E+00
6.76E+00
6.60E+00
6.79E+00
6.97E+00
6.96E+00
6.93E+00 6.90E+00 6.91E+00 6.90E+00 6.87E+00 6.86E+00 6.87E+00
2.13E-01 1.82E-01 2.11E-01 1.83E-01 1.77E-01 1.84E-01 1.88E-01
7.52E+00 7.40E+00 7.49E+00 7.40E+00 7.36E+00 7.36E+00 7.39E+00
6.35E+00 6.41E+00 6.33E+00 6.40E+00 6.39E+00 6.35E+00 6.36E+00
6.83E+00
1.25E-01
7.17E+00
6.48E+00
3.50E+00
PASS
6.81E+00
1.29E-01
7.16E+00
6.46E+00
3.00E+00
PASS
6.79E+00
1.31E-01
7.15E+00
6.44E+00
3.00E+00
PASS
6.79E+00
1.48E-01
7.20E+00
6.39E+00
3.00E+00
PASS
6.74E+00
1.18E-01
7.07E+00
6.42E+00
3.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
394
6.74E+00
1.28E-01
7.09E+00
6.39E+00
3.00E+00
PASS
6.76E+00
1.34E-01
7.13E+00
6.39E+00
3.00E+00
PASS
+Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
8.00E+00
7.00E+00
6.00E+00
5.00E+00
4.00E+00
3.00E+00
2.00E+00
1.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.192. Plot of +Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
395
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.192. Raw data for +Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
+Slew Rate_4 15V (V/us)
@ VS=+/-15, AV=-1, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
6.91E+00
7.12E+00
7.24E+00
7.39E+00
7.25E+00
7.25E+00
6.91E+00
7.10E+00
7.12E+00
7.05E+00
6.72E+00
6.98E+00
10
6.92E+00
7.09E+00
7.15E+00
7.36E+00
7.23E+00
7.23E+00
6.91E+00
7.12E+00
7.10E+00
7.04E+00
6.78E+00
6.99E+00
Total Dose (krad(Si))
20
30
6.91E+00 6.90E+00
7.04E+00 7.10E+00
7.13E+00 7.14E+00
7.30E+00 7.31E+00
7.22E+00 7.17E+00
7.15E+00 7.16E+00
6.92E+00 6.90E+00
7.12E+00 7.10E+00
7.09E+00 7.09E+00
7.11E+00 7.05E+00
6.74E+00 6.75E+00
6.91E+00 6.95E+00
50
6.88E+00
7.08E+00
7.09E+00
7.22E+00
7.12E+00
7.09E+00
6.86E+00
7.07E+00
7.07E+00
6.98E+00
6.76E+00
6.93E+00
24 Hr
Anneal
60
6.88E+00
7.08E+00
7.07E+00
7.25E+00
7.12E+00
7.10E+00
6.84E+00
7.04E+00
7.02E+00
7.01E+00
6.73E+00
6.95E+00
168 Hr
Anneal
70
6.87E+00
7.05E+00
7.11E+00
7.23E+00
7.16E+00
7.12E+00
6.87E+00
7.08E+00
7.03E+00
7.03E+00
6.74E+00
6.95E+00
7.18E+00 7.15E+00 7.12E+00 7.12E+00 7.08E+00 7.08E+00 7.08E+00
1.80E-01 1.64E-01 1.52E-01 1.48E-01 1.24E-01 1.33E-01 1.37E-01
7.67E+00 7.60E+00 7.54E+00 7.53E+00 7.42E+00 7.44E+00 7.46E+00
6.69E+00 6.70E+00 6.70E+00 6.72E+00 6.74E+00 6.72E+00 6.71E+00
7.09E+00
1.23E-01
7.42E+00
6.75E+00
3.50E+00
PASS
7.08E+00
1.17E-01
7.40E+00
6.76E+00
3.00E+00
PASS
7.08E+00
9.09E-02
7.33E+00
6.83E+00
3.00E+00
PASS
7.06E+00
9.77E-02
7.33E+00
6.79E+00
3.00E+00
PASS
7.01E+00
9.61E-02
7.28E+00
6.75E+00
3.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
396
7.00E+00
9.71E-02
7.27E+00
6.74E+00
3.00E+00
PASS
7.03E+00
9.50E-02
7.29E+00
6.77E+00
3.00E+00
PASS
-Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
8.00E+00
7.00E+00
6.00E+00
5.00E+00
4.00E+00
3.00E+00
2.00E+00
1.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.193. Plot of -Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
397
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.193. Raw data for -Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Slew Rate_1 15V (V/us)
@ VS=+/-15, AV=-1, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
6.47E+00
6.64E+00
6.78E+00
6.78E+00
6.67E+00
6.74E+00
6.44E+00
6.77E+00
6.53E+00
6.55E+00
6.19E+00
6.51E+00
10
6.44E+00
6.60E+00
6.75E+00
6.79E+00
6.64E+00
6.72E+00
6.44E+00
6.72E+00
6.50E+00
6.57E+00
6.17E+00
6.51E+00
Total Dose (krad(Si))
20
30
6.43E+00 6.44E+00
6.55E+00 6.58E+00
6.75E+00 6.71E+00
6.80E+00 6.78E+00
6.64E+00 6.62E+00
6.72E+00 6.72E+00
6.43E+00 6.39E+00
6.71E+00 6.70E+00
6.50E+00 6.50E+00
6.53E+00 6.54E+00
6.18E+00 6.17E+00
6.57E+00 6.50E+00
50
6.40E+00
6.53E+00
6.72E+00
6.75E+00
6.59E+00
6.64E+00
6.33E+00
6.69E+00
6.43E+00
6.50E+00
6.20E+00
6.52E+00
24 Hr
Anneal
60
6.39E+00
6.51E+00
6.63E+00
6.73E+00
6.55E+00
6.65E+00
6.35E+00
6.64E+00
6.44E+00
6.47E+00
6.19E+00
6.50E+00
168 Hr
Anneal
70
6.38E+00
6.54E+00
6.70E+00
6.76E+00
6.57E+00
6.66E+00
6.35E+00
6.66E+00
6.47E+00
6.50E+00
6.21E+00
6.50E+00
6.67E+00 6.64E+00 6.63E+00 6.63E+00 6.60E+00 6.56E+00 6.59E+00
1.28E-01 1.38E-01 1.50E-01 1.30E-01 1.43E-01 1.28E-01 1.48E-01
7.02E+00 7.02E+00 7.04E+00 6.98E+00 6.99E+00 6.91E+00 7.00E+00
6.32E+00 6.27E+00 6.22E+00 6.27E+00 6.21E+00 6.21E+00 6.18E+00
6.61E+00
1.43E-01
7.00E+00
6.22E+00
3.50E+00
PASS
6.59E+00
1.27E-01
6.94E+00
6.24E+00
3.00E+00
PASS
6.58E+00
1.30E-01
6.94E+00
6.22E+00
3.00E+00
PASS
6.57E+00
1.39E-01
6.95E+00
6.19E+00
3.00E+00
PASS
6.52E+00
1.48E-01
6.92E+00
6.11E+00
3.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
398
6.51E+00
1.31E-01
6.87E+00
6.15E+00
3.00E+00
PASS
6.53E+00
1.33E-01
6.89E+00
6.16E+00
3.00E+00
PASS
-Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
8.00E+00
7.00E+00
6.00E+00
5.00E+00
4.00E+00
3.00E+00
2.00E+00
1.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.194. Plot of -Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
399
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.194. Raw data for -Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Slew Rate_2 15V (V/us)
@ VS=+/-15, AV=-1, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
6.66E+00
7.13E+00
6.91E+00
6.83E+00
6.70E+00
6.84E+00
6.69E+00
6.77E+00
6.46E+00
6.70E+00
6.97E+00
6.93E+00
10
6.62E+00
7.09E+00
6.86E+00
6.83E+00
6.68E+00
6.82E+00
6.65E+00
6.75E+00
6.43E+00
6.71E+00
6.99E+00
6.95E+00
Total Dose (krad(Si))
20
30
6.61E+00 6.59E+00
7.11E+00 7.12E+00
6.85E+00 6.84E+00
6.81E+00 6.80E+00
6.64E+00 6.64E+00
6.81E+00 6.81E+00
6.62E+00 6.67E+00
6.73E+00 6.75E+00
6.45E+00 6.44E+00
6.68E+00 6.67E+00
6.99E+00 6.95E+00
6.98E+00 6.96E+00
50
6.54E+00
7.05E+00
6.79E+00
6.73E+00
6.58E+00
6.76E+00
6.57E+00
6.68E+00
6.38E+00
6.65E+00
6.95E+00
6.92E+00
24 Hr
Anneal
60
6.54E+00
7.07E+00
6.81E+00
6.73E+00
6.62E+00
6.72E+00
6.58E+00
6.65E+00
6.36E+00
6.62E+00
6.96E+00
6.85E+00
168 Hr
Anneal
70
6.57E+00
7.09E+00
6.80E+00
6.76E+00
6.61E+00
6.75E+00
6.62E+00
6.68E+00
6.41E+00
6.67E+00
6.97E+00
6.92E+00
6.85E+00 6.82E+00 6.80E+00 6.80E+00 6.74E+00 6.75E+00 6.77E+00
1.88E-01 1.83E-01 2.00E-01 2.08E-01 2.03E-01 2.05E-01 2.05E-01
7.36E+00 7.32E+00 7.35E+00 7.37E+00 7.29E+00 7.31E+00 7.33E+00
6.33E+00 6.31E+00 6.26E+00 6.23E+00 6.18E+00 6.19E+00 6.20E+00
6.69E+00
1.43E-01
7.08E+00
6.30E+00
3.50E+00
PASS
6.67E+00
1.49E-01
7.08E+00
6.26E+00
3.00E+00
PASS
6.66E+00
1.36E-01
7.03E+00
6.29E+00
3.00E+00
PASS
6.67E+00
1.40E-01
7.05E+00
6.28E+00
3.00E+00
PASS
6.61E+00
1.44E-01
7.00E+00
6.21E+00
3.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
400
6.59E+00
1.36E-01
6.96E+00
6.21E+00
3.00E+00
PASS
6.63E+00
1.29E-01
6.98E+00
6.27E+00
3.00E+00
PASS
-Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
7.00E+00
6.00E+00
5.00E+00
4.00E+00
3.00E+00
2.00E+00
1.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.195. Plot of -Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
401
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.195. Raw data for -Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Slew Rate_3 15V (V/us)
@ VS=+/-15, AV=-1, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
6.44E+00
6.88E+00
6.77E+00
6.64E+00
6.38E+00
6.66E+00
6.53E+00
6.59E+00
6.28E+00
6.55E+00
6.68E+00
6.65E+00
10
6.43E+00
6.84E+00
6.75E+00
6.62E+00
6.36E+00
6.64E+00
6.52E+00
6.55E+00
6.26E+00
6.52E+00
6.69E+00
6.70E+00
Total Dose (krad(Si))
20
30
6.42E+00 6.41E+00
6.81E+00 6.79E+00
6.72E+00 6.71E+00
6.61E+00 6.58E+00
6.35E+00 6.35E+00
6.62E+00 6.63E+00
6.49E+00 6.47E+00
6.59E+00 6.55E+00
6.28E+00 6.26E+00
6.49E+00 6.49E+00
6.66E+00 6.70E+00
6.73E+00 6.70E+00
50
6.35E+00
6.80E+00
6.66E+00
6.54E+00
6.28E+00
6.57E+00
6.42E+00
6.51E+00
6.20E+00
6.47E+00
6.69E+00
6.69E+00
24 Hr
Anneal
60
6.37E+00
6.76E+00
6.64E+00
6.49E+00
6.27E+00
6.58E+00
6.43E+00
6.52E+00
6.19E+00
6.43E+00
6.65E+00
6.67E+00
168 Hr
Anneal
70
6.39E+00
6.80E+00
6.68E+00
6.55E+00
6.28E+00
6.57E+00
6.42E+00
6.51E+00
6.19E+00
6.47E+00
6.65E+00
6.70E+00
6.62E+00 6.60E+00 6.58E+00 6.57E+00 6.53E+00 6.51E+00 6.54E+00
2.12E-01 2.04E-01 1.95E-01 1.88E-01 2.15E-01 1.98E-01 2.11E-01
7.20E+00 7.16E+00 7.12E+00 7.08E+00 7.12E+00 7.05E+00 7.12E+00
6.04E+00 6.04E+00 6.05E+00 6.05E+00 5.94E+00 5.96E+00 5.96E+00
6.52E+00
1.44E-01
6.92E+00
6.13E+00
3.50E+00
PASS
6.50E+00
1.42E-01
6.89E+00
6.11E+00
3.00E+00
PASS
6.49E+00
1.33E-01
6.86E+00
6.13E+00
3.00E+00
PASS
6.48E+00
1.38E-01
6.86E+00
6.10E+00
3.00E+00
PASS
6.43E+00
1.42E-01
6.82E+00
6.04E+00
3.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
402
6.43E+00
1.48E-01
6.84E+00
6.02E+00
3.00E+00
PASS
6.43E+00
1.46E-01
6.83E+00
6.03E+00
3.00E+00
PASS
-Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
ELDRS Report
12-640 130125 R1.1
Average Biased
Average Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Ps90%/90% (-KTL) Biased
8.00E+00
7.00E+00
6.00E+00
5.00E+00
4.00E+00
3.00E+00
2.00E+00
1.00E+00
0.00E+00
0
10
20
30
40
50
24 Hr
60
Anneal
168 Hr
70
Anneal
Total Dose (krad(Si))
Figure 5.196. Plot of -Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose. The solid
diamonds are the average of the measured data points for the samples irradiated under electrical bias while the
shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to
ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL
statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average
of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The
red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in
the datasheet and/or test plan.
An ISO 9001:2008 and DSCC Certified Company
403
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table 5.196. Raw data for -Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ versus total dose,
including the statistical analysis, specification and the status of the testing (pass/fail).
-Slew Rate_4 15V (V/us)
@ VS=+/-15, AV=-1, RL=10kΩ
Device
557
563
564
567
569
570
571
572
573
574
584
585
Biased Statistics
Average Biased
Std Dev Biased
Ps90%/90% (+KTL) Biased
Ps90%/90% (-KTL) Biased
Un-Biased Statistics
Average Un-Biased
Std Dev Un-Biased
Ps90%/90% (+KTL) Un-Biased
Ps90%/90% (-KTL) Un-Biased
Specification MIN
Status
0
6.66E+00
6.91E+00
7.00E+00
7.11E+00
6.99E+00
6.95E+00
6.74E+00
6.90E+00
6.80E+00
6.82E+00
6.52E+00
6.79E+00
10
6.65E+00
6.87E+00
6.96E+00
7.08E+00
6.96E+00
6.95E+00
6.70E+00
6.92E+00
6.81E+00
6.78E+00
6.52E+00
6.81E+00
Total Dose (krad(Si))
20
30
6.61E+00 6.65E+00
6.87E+00 6.87E+00
6.90E+00 6.93E+00
7.06E+00 7.06E+00
6.91E+00 6.92E+00
6.93E+00 6.94E+00
6.71E+00 6.74E+00
6.87E+00 6.89E+00
6.78E+00 6.78E+00
6.81E+00 6.75E+00
6.53E+00 6.53E+00
6.81E+00 6.81E+00
50
6.56E+00
6.81E+00
6.88E+00
6.98E+00
6.88E+00
6.83E+00
6.68E+00
6.82E+00
6.73E+00
6.73E+00
6.50E+00
6.81E+00
24 Hr
Anneal
60
6.57E+00
6.81E+00
6.85E+00
6.93E+00
6.86E+00
6.83E+00
6.64E+00
6.80E+00
6.69E+00
6.74E+00
6.51E+00
6.77E+00
168 Hr
Anneal
70
6.59E+00
6.83E+00
6.91E+00
6.99E+00
6.90E+00
6.88E+00
6.67E+00
6.83E+00
6.74E+00
6.73E+00
6.52E+00
6.81E+00
6.93E+00 6.90E+00 6.87E+00 6.89E+00 6.82E+00 6.80E+00 6.84E+00
1.69E-01 1.60E-01 1.63E-01 1.49E-01 1.58E-01 1.38E-01 1.53E-01
7.40E+00 7.34E+00 7.32E+00 7.30E+00 7.26E+00 7.18E+00 7.26E+00
6.47E+00 6.46E+00 6.42E+00 6.48E+00 6.39E+00 6.43E+00 6.42E+00
6.84E+00
8.32E-02
7.07E+00
6.61E+00
3.50E+00
PASS
6.83E+00
1.03E-01
7.11E+00
6.55E+00
3.00E+00
PASS
6.82E+00
8.43E-02
7.05E+00
6.59E+00
3.00E+00
PASS
6.82E+00
8.97E-02
7.07E+00
6.57E+00
3.00E+00
PASS
6.76E+00
6.46E-02
6.94E+00
6.58E+00
3.00E+00
PASS
An ISO 9001:2008 and DSCC Certified Company
404
6.74E+00
7.78E-02
6.95E+00
6.53E+00
3.00E+00
PASS
6.77E+00
8.40E-02
7.00E+00
6.54E+00
3.00E+00
PASS
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
6.0. Summary / Conclusions
The low dose rate testing described in this final report was performed using the facilities at Aeroflex
RAD's Longmire Laboratories in Colorado Springs, CO. The low dose rate source is a GB-150 irradiator
modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily
shielded by lead. During the irradiation exposures the rod is raised by an electronic timer/controller and
the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from
approximately 1mrad(Si)/s to a maximum of approximately 50rad(Si)/s, determined by the distance
from the source.
The parametric data was obtained as "read and record" and all the raw data plus an attributes summary
are contained in this report as well as in a separate Excel file. The attributes data contains the average,
standard deviation and the average with the KTL values applied. The KTL value used in this work is
2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The
90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535
sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the
following criteria must be met for a device to pass the low dose rate test: following the radiation
exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units
irradiated without electrical bias and the KTL statistics are included in this report for reference only. If
any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet
specification limits, then the lot could be logged as a failure.
Based on this criterion the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp
(from the lot date code identified on the first page of this test report) PASSED the enhanced low dose
rate sensitivity test to the maximum tested dose level of 50krad(Si) with all parameters remaining within
their datasheet specifications. Further, the data in this report can be analyzed along with the high dose
rate report titled "Total Ionizing Dose (TID) Radiation Testing of the RH1499MW Quad Rail-to-Rail
Input and Output Precision C-Load Op Amp for Linear Technology" to demonstrate that these parts do
not exhibit ELDRS as defined in the current test method.
An ISO 9001:2008 and DSCC Certified Company
405
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix A: Photograph of Packing Label and a Sample Unit-Under-Test to Show Part
Traceability
An ISO 9001:2008 and DSCC Certified Company
406
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix B: Radiation Bias Connections and Absolute Maximum Ratings
ELDRS Radiation Biased Conditions: Extracted from Linear Technology RH1499M datasheet, ID No
66-10-1499.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Function
OUT A
-INPUT A
+INPUT A
V+
+INPUT B
-INPUT B
OUT B
OUT C
-INPUT C
+INPUT C
V+INPUT D
-INPUT D
OUT D
Connection / Bias
To Pin 2 via 5kΩ & 40pF, in Parallel
To Pin 1 via 5kΩ & 40pF, in Parallel
To 8V via 5kΩ Resistor
To +15V using 0.1µF Decoupling
To 8V via 5kΩ Resistor
To Pin 7 via 5kΩ & 40pF, in Parallel
To Pin 6 via 5kΩ & 40pF, in Parallel
To Pin 9 via 5kΩ & 40pF, in Parallel
To Pin 8 via 5kΩ & 40pF, in Parallel
To 8V via 5kΩ Resistor
To -15V using 0.1µF Decoupling
To 8V via 10kΩ Resistor
To Pin 14 via 5kΩ & 40pF, in Parallel
To Pin 13 via 5kΩ & 40pF, in Parallel
Figure B.1. Irradiation bias circuit. This figure was extracted from Linear Technology RH1499M datasheet, ID
No 66-10-1499.
An ISO 9001:2008 and DSCC Certified Company
407
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
ELDRS Radiation Unbiased Conditions:
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Function
OUT A
-INPUT A
+INPUT A
V+
+INPUT B
-INPUT B
OUT B
OUT C
-INPUT C
+INPUT C
V+INPUT D
-INPUT D
OUT D
Connection / Bias
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
Figure B.2. W package drawing (for reference only). This figure was extracted from Linear Technology
RH1499M datasheet, ID No 66-10-1499.
Absolute Maximum Ratings:
Parameter
Total Supply Voltage (V+ to V-)
Input Current
Output Short-Circuit Duration
Max Rating
36V
±10mA
Continuous
An ISO 9001:2008 and DSCC Certified Company
408
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix C: Electrical Test Parameters and Conditions
The expected ranges of values as well as the measurement conditions are taken from Linear Technology
RH1499M datasheet. All electrical tests for this device are performed on one of Aeroflex RAD's
LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that provides
parameter measurements for a variety of digital, analog and mixed signal products including voltage
regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System achieves
accuracy and sensitivity through the use of software self-calibration and an internal relay matrix with
separate family boards and custom personality adapter boards. The tester uses this relay matrix to
connect the required test circuits, select the appropriate voltage / current sources and establish the
needed measurement loops for all the tests performed. The measured parameters and test conditions are
shown in Table C.1.
A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The
precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020
for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table
C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between
tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90
KTL statistics were applied to the measured standard deviation to generate the final measurement range.
This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020
mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the
measurement resolution is limited by the internal DACs, which results in a measured standard deviation
of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC.
Note that the testing and statistics used in this document are based on an “analysis of variables”
technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p.
91 for a discussion of statistical treatments). Not all measured parameters are well suited to this
approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify
these parameters using an “attributes” approach.
An ISO 9001:2008 and DSCC Certified Company
409
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table C.1. Measured parameters and test conditions for the RH1499MW Quad Rail-to-Rail Input and Output
Precision C-Load Op Amp.
Parameter
Symbol
Test Conditions
+Supply Current 15V (A)
+ICC15
VS=+/-15V
-Supply Current 15V (A)
-IEE15
VS=+/-15V
Input Offset Voltage1 15V (V)
VOS1_14 15V
VS=+/-15V, VCM=0V
Input Offset Current1 15V (A)
IOS1_14 15V
VS=+/-15V, VCM=0V
+Input Bias Current BIAS1 15V (A)
+IBIAS1_14 15V
VS=+/-15V, VCM=0V
-Input Bias Current BIAS1 15V (A)
-IBIAS1_14 15V
VS=+/-15V, VCM=0V
Input Offset Voltage2 15V (V)
VOS2_14 15V
VS=+/-15V, VCM=15V
Input Offset Current2 15V (A)
IOS2_14 15V
VS=+/-15V, VCM=15V
+Input Bias Current BIAS2 15V (A)
+IBIAS2_14 15V
VS=+/-15V, VCM=15V
-Input Bias Current BIAS2 15V (A)
-IBIAS2_14 15V
VS=+/-15V, VCM=15V
Input Offset Voltage3 15V (V)
VOS3_14 15V
VS=+/-15V, VCM=-15V
Input Offset Current3 15V (A)
IOS3_14 15V
VS=+/-15V, VCM=-15V
+Input Bias Current BIAS3 15V (A)
+IBIAS3_14 15V
VS=+/-15V, VCM=-15V
-Input Bias Current BIAS3 15V (A)
-IBIAS3_14 15V
VS=+/-15V, VCM=-15V
Output Voltage Swing High1 15V (V)
+VOUT1_14 15V
VS=+/-15V IL=0mA
Output Voltage Swing High2 15V (V)
+VOUT2_14 15V
VS=+/-15V IL=1mA
Output Voltage Swing High3 15V (V)
+VOUT3_14 15V
VS=+/-15V IL=10mA
Output Voltage Swing Low1 15V (V)
-VOUT1_14 15V
VS=+/-15V IL=0mA
Output Voltage Swing Low2 15V (V)
-VOUT2_14 15V
VS=+/-15V IL=1mA
Output Voltage Swing Low3 15V (V)
-VOUT3_14 15V
VS=+/-15V IL=10mA
Large Signal Voltage Gain1 15V (V/mV)
AVOL1_14 15V
VO=+/-14.5V, RL=10kΩ
Large Signal Voltage Gain2 15V (V/mV)
AVOL2_14 15V
VO=+/-10V, RL=2kΩ
Common Mode Rejection Ratio1 15V (dB) CMRR1_14 15V
VS=+/-15V, VCM=+/-15V
CMRR Match1 1 to 4 15V (dB)
CMRR1 MATCH 1 to 4 15V VS=+/-15V, VCM=+/-15V
CMRR Match1 2 to 3 15V (dB)
CMRR1 MATCH 2 to 3 15V VS=+/-15V, VCM=+/-15V
Power Supply Rejection Ratio1 (dB)
PSRR1_14
VS=+/-2V to +/-16V
PSRR Match1 1 to 4 (dB)
PSRR1 MATCH 1 to 4
VS=+/-2V to +/-16V
PSRR Match1 2 to 3 (dB)
PSRR1 MATCH 2 to 3
VS=+/-2V to +/-16V
An ISO 9001:2008 and DSCC Certified Company
410
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
+Short-Circuit Current1 15V (A)
+ISC1_14 15V
VS=+/-15V, VOUT=0V
-Short-Circuit Current1 15V (A)
-ISC1_14 15V
VS=+/-15V, VOUT=0V
+Supply Current 5V (A)
+ICC5
VS=+5V
-Supply Current 5V (A)
-IEE5
VS=+5V
Input Offset Voltage4 5V (V)
VOS4_14 5V
VS=+5V, VCM=0V
Input Offset Current4 5V (A)
IOS4_14 5V
VS=+5V, VCM=0V
+Input Bias Current BIAS4 5V (A)
+IBIAS4_14 5V
VS=+5V, VCM=0V
-Input Bias Current BIAS4 5V (A)
-IBIAS4_14 5V
VS=+5V, VCM=0V
Input Offset Voltage5 5V (V)
VOS5_14 5V
VS=+5V, VCM=5V
Input Offset Current5 5V (A)
IOS5_14 5V
VS=+5V, VCM=5V
+Input Bias Current BIAS5 5V (A)
+IBIAS5_14 5V
VS=+5V, VCM=5V
-Input Bias Current BIAS5 5V (A)
-IBIAS5_14 5V
VS=+5V, VCM=5V
Output Voltage Swing High4 5V (V)
+VOUT4_14 5V
VS=+5V IL=0mA
Output Voltage Swing High5 5V (V)
+VOUT5_14 5V
VS=+5V IL=1mA
Output Voltage Swing High6 5V (V)
+VOUT6_14 5V
VS=+5V IL=2.5mA
Output Voltage Swing Low4 5V (V)
-VOUT4_14 5V
VS=+5V IL=0mA
Output Voltage Swing Low5 5V (V)
-VOUT5_14 5V
VS=+5V IL=1mA
Output Voltage Swing Low6 5V (V)
-VOUT6_14 5V
VS=+5V IL=2.5mA
Large Signal Voltage Gain3 5V (V/mV)
AVOL3_14 5V
VO=75mV to 4.8V, RL=10kΩ
Common Mode Rejection Ratio2 5V (dB)
CMRR2_14 5V
VS=+5V, VCM=0 to +5V
CMRR Match2 1 to 4 5V (dB)
CMRR2 MATCH 1 to 4 5V
VS=+5V, VCM=0 to +5V
CMRR Match2 2 to 3 5V (dB)
CMRR2 MATCH 2 to 3 5V
VS=+5V, VCM=0 to +5V
Power Supply Rejection Ratio2 (dB)
PSRR2_14
VS=+4.5V to +12V
PSRR Match2 1 to 4 (dB)
PSRR2 MATCH 1 to 4
VS=+4.5V to +12V
PSRR Match2 2 to 3 (dB)
PSRR2 MATCH 2 to 3
VS=+4.5V to +12V
+Short-Circuit Current2 5V (A)
+ISC2_14 5V
VS=+5V
-Short-Circuit Current2 5V (A)
-ISC2_14 5V
VS=+5V
Gain-Bandwidth Product 15V (MHz)
GBW_14 15V
+Slew Rate 15V (V/us)
+SR_14 5V
-Slew Rate 15V (V/us)
-SR_14 5V
VS=+/-15V, f=100kHz
VS=+/-15V, AV=-1, RL=10K,
VO=+/-10V
VS=+/-15V, AV=-1, RL=10K,
VO=+/-10V
An ISO 9001:2008 and DSCC Certified Company
411
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH1499MW
Quad Rail-to-Rail Input and Output Precision C-Load Op Amp.
Pre-Irradiation
Specification
MIN
MAX
Parameter
+Supply Current 15V (A)
1.00E-02
Measurement
Precision/Resolution
±1.64E-04
-Supply Current 15V (A)
-1.00E-02
±1.61E-04
Input Offset Voltage1 15V (V)
-8.00E-04
8.00E-04
±2.51E-05
Input Offset Current1 15V (A)
-7.00E-08
7.00E-08
±9.10E-10
+Input Bias Current BIAS1 15V (A)
-7.15E-07
7.15E-07
±1.22E-08
-Input Bias Current BIAS1 15V (A)
-7.15E-07
7.15E-07
±1.13E-08
Input Offset Voltage2 15V (V)
-8.00E-04
8.00E-04
±1.28E-05
Input Offset Current2 15V (A)
-7.00E-08
7.00E-08
±9.67E-10
+Input Bias Current BIAS2 15V (A)
-7.15E-07
7.15E-07
±7.21E-09
-Input Bias Current BIAS2 15V (A)
-7.15E-07
7.15E-07
±6.44E-09
Input Offset Voltage3 15V (V)
-8.00E-04
8.00E-04
±1.65E-05
Input Offset Current3 15V (A)
-7.00E-08
7.00E-08
±7.00E-10
+Input Bias Current BIAS3 15V (A)
-7.15E-07
7.15E-07
±1.01E-08
-Input Bias Current BIAS3 15V (A)
-7.15E-07
7.15E-07
±8.88E-09
Output Voltage Swing High1 15V (V)
1.00E-02
±2.81E-04
Output Voltage Swing High2 15V (V)
1.50E-01
±1.19E-03
Output Voltage Swing High3 15V (V)
8.00E-01
±6.15E-03
Output Voltage Swing Low1 15V (V)
3.00E-02
±5.56E-04
Output Voltage Swing Low2 15V (V)
1.00E-01
±1.03E-03
Output Voltage Swing Low3 15V (V)
5.00E-01
±3.44E-03
Large Signal Voltage Gain1 15V (V/mV)
1.00E+03
±2.28E+02
Large Signal Voltage Gain2 15V (V/mV)
Common Mode Rejection Ratio1 15V
(dB)
CMRR Match1 1 to 4 15V (dB)
5.00E+01
±1.55E+01
9.00E+01
3.00E+02
±9.45E-02
8.40E+01
3.00E+02
±6.79E-02
CMRR Match1 2 to 3 15V (dB)
8.40E+01
3.00E+02
±1.71E-01
Power Supply Rejection Ratio1 (dB)
9.00E+01
±3.82E-01
PSRR Match1 1 to 4 (dB)
8.30E+01
±1.35E-01
An ISO 9001:2008 and DSCC Certified Company
412
ELDRS Report
12-640 130125 R1.1
PSRR Match1 2 to 3 (dB)
8.30E+01
+Short-Circuit Current1 15V (A)
-Short-Circuit Current1 15V (A)
±8.96E-02
-1.50E-02
1.50E-02
+Supply Current 5V (A)
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
±4.01E-04
±6.44E-04
8.80E-03
±8.67E-05
-Supply Current 5V (A)
-8.80E-03
±8.59E-05
Input Offset Voltage4 5V (V)
-8.00E-04
8.00E-04
±1.49E-05
Input Offset Current4 5V (A)
-6.50E-08
6.50E-08
±5.28E-10
+Input Bias Current BIAS4 5V (A)
-6.50E-07
6.50E-07
±6.11E-09
-Input Bias Current BIAS4 5V (A)
-6.50E-07
6.50E-07
±6.24E-09
Input Offset Voltage5 5V (V)
-8.00E-04
8.00E-04
±8.65E-06
Input Offset Current5 5V (A)
-6.50E-08
6.50E-08
±5.15E-10
+Input Bias Current BIAS5 5V (A)
-6.50E-07
6.50E-07
±3.27E-09
-Input Bias Current BIAS5 5V (A)
-6.50E-07
6.50E-07
±2.91E-09
Output Voltage Swing High4 5V (V)
1.00E-02
±2.53E-04
Output Voltage Swing High5 5V (V)
1.50E-01
±8.19E-04
Output Voltage Swing High6 5V (V)
2.50E-01
±1.46E-03
Output Voltage Swing Low4 5V (V)
3.00E-02
±3.86E-04
Output Voltage Swing Low5 5V (V)
1.00E-01
±4.14E-04
Output Voltage Swing Low6 5V (V)
2.00E-01
±7.42E-04
Large Signal Voltage Gain3 5V (V/mV)
6.00E+02
±5.72E+02
Common Mode Rejection Ratio2 5V (dB)
7.60E+01
±1.49E-01
CMRR Match2 1 to 4 5V (dB)
7.50E+01
±5.95E-02
CMRR Match2 2 to 3 5V (dB)
7.50E+01
±3.80E-01
Power Supply Rejection Ratio2 (dB)
8.80E+01
±4.26E+00
PSRR Match2 1 to 4 (dB)
8.20E+01
±1.05E+00
PSRR Match2 2 to 3 (dB)
8.20E+01
±6.39E-01
+Short-Circuit Current2 5V (A)
-1.25E-02
±4.02E-05
-Short-Circuit Current2 5V (A)
1.25E-02
±4.63E-04
Gain-Bandwidth Product 15V (MHz)
6.80E+00
±3.78E-02
+Slew Rate 15V (V/us)
3.50E+00
±5.70E-02
-Slew Rate 15V (V/us)
3.50E+00
±5.70E-02
An ISO 9001:2008 and DSCC Certified Company
413
ELDRS Report
12-640 130125 R1.1
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
Appendix D: List of Figures Used in the Results Section (Section 5)
5.1.
5.2.
5.3.
5.4.
5.5.
5.6.
5.7.
5.8.
5.9.
5.10.
5.11.
5.12.
5.13.
5.14.
5.15.
5.16.
5.17.
5.18.
5.19.
5.20.
5.21.
5.22.
5.23.
5.24.
5.25.
5.26.
5.27.
5.28.
5.29.
5.30.
5.31.
5.32.
5.33.
5.34.
5.35.
5.36.
5.37.
5.38.
5.39.
5.40.
5.41.
5.42.
5.43.
5.44.
+Supply Current 15V (A) @ VS=+/-15V
-Supply Current 15V (A) @ VS=+/-15V
Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V
Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V
Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V
Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V
Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V
Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V
Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V
Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V
+Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V
+Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V
+Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V
+Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V
-Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V
-Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V
-Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V
-Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V
Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V
Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V
Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V
Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V
Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V
Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V
Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V
Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V
+Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V
+Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V
+Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V
+Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V
-Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V
-Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V
-Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V
-Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V
Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V
Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V
Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V
Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V
Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V
Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V
Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V
Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V
+Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V
+Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V
An ISO 9001:2008 and DSCC Certified Company
414
ELDRS Report
12-640 130125 R1.1
5.45.
5.46.
5.47.
5.48.
5.49.
5.50.
5.51.
5.52.
5.53.
5.54.
5.55.
5.56.
5.57.
5.58.
5.59.
5.60.
5.61.
5.62.
5.63.
5.64.
5.65.
5.66.
5.67.
5.68.
5.69.
5.70.
5.71.
5.72.
5.73.
5.74.
5.75.
5.76.
5.77.
5.78.
5.79.
5.80.
5.81.
5.82.
5.83.
5.84.
5.85.
5.86.
5.87.
5.88.
5.89.
5.90.
+Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V
+Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V
-Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V
-Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V
-Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V
-Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V
Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA
Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA
Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA
Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA
Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ
Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ
Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ
Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ
Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ
Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ
Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ
Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ
Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V
Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V
Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V
Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V
CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V
CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V
Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V
Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V
An ISO 9001:2008 and DSCC Certified Company
415
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
ELDRS Report
12-640 130125 R1.1
5.91.
5.92.
5.93.
5.94.
5.95.
5.96.
5.97.
5.98.
5.99.
5.100.
5.101.
5.102.
5.103.
5.104.
5.105.
5.106.
5.107.
5.108.
5.109.
5.110.
5.111.
5.112.
5.113.
5.114.
5.115.
5.116.
5.117.
5.118.
5.119.
5.120.
5.121.
5.122.
5.123.
5.124.
5.125.
5.126.
5.127.
5.128.
5.129.
5.130.
5.131.
5.132.
5.133.
5.134.
5.135.
5.136.
Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V
Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V
PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V
PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V
+Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V
+Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V
+Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V
+Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V
-Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V
-Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V
-Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V
-Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V
+Supply Current 5V (A) @ VS=+5V
-Supply Current 5V (A) @ VS=+5V
Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V
Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V
Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V
Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V
Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V
Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V
Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V
Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V
+Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V
+Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V
+Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V
+Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V
-Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V
-Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V
-Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V
-Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V
Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V
Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V
Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V
Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V
Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V
Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V
Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V
Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V
+Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V
+Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V
+Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V
+Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V
-Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V
-Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V
-Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V
-Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V
An ISO 9001:2008 and DSCC Certified Company
416
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
ELDRS Report
12-640 130125 R1.1
5.137.
5.138.
5.139.
5.140.
5.141.
5.142.
5.143.
5.144.
5.145.
5.146.
5.147.
5.148.
5.149.
5.150.
5.151.
5.152.
5.153.
5.154.
5.155.
5.156.
5.157.
5.158.
5.159.
5.160.
5.161.
5.162.
5.163.
5.164.
5.165.
5.166.
5.167.
5.168.
5.169.
5.170.
5.171.
5.172.
5.173.
5.174.
5.175.
5.176.
5.177.
5.178.
5.179.
5.180.
5.181.
5.182.
Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA
Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA
Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA
Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA
Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA
Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA
Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA
Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA
Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA
Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA
Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA
Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA
Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA
Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA
Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA
Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA
Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA
Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA
Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA
Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA
Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA
Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA
Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA
Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA
Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ
Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ
Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ
Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ
Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V
Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V
Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V
Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V
CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V
CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V
Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V
Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V
Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V
Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V
PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V
PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V
+Short-Circuit Current2 1 5V (A) @ VS=+5V
+Short-Circuit Current2 2 5V (A) @ VS=+5V
+Short-Circuit Current2 3 5V (A) @ VS=+5V
+Short-Circuit Current2 4 5V (A) @ VS=+5V
-Short-Circuit Current2 1 5V (A) @ VS=+5V
-Short-Circuit Current2 2 5V (A) @ VS=+5V
An ISO 9001:2008 and DSCC Certified Company
417
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800
ELDRS Report
12-640 130125 R1.1
5.183.
5.184.
5.185.
5.186.
5.187.
5.188.
5.189.
5.190.
5.191.
5.192.
5.193.
5.194.
5.195.
5.196.
-Short-Circuit Current2 3 5V (A) @ VS=+5V
-Short-Circuit Current2 4 5V (A) @ VS=+5V
Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz
Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz
Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz
Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz
+Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
+Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
+Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
+Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
-Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
-Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
-Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
-Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ
An ISO 9001:2008 and DSCC Certified Company
418
Aeroflex RAD
5017 N. 30th Street
Colorado Springs, CO 80919
(719) 531-0800