TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Products contained in this shipment may be subject to ITAR regulations. Warning: The export of these commodity(ies), technology, or software are subject either to the U.S. Commerce Department Export Administration Regulations (E.A.R.), or to the U.S. State Department International Traffic In Arms Regulations (I.T.A.R.). Diversion, the shipment to unauthorized locations or entities, or the disclosure of related technical data or software to unauthorized foreign nationals is contrary to U.S. law and is prohibited. If export is authorized to a specific country or end-users, compliance with the U.S. export laws is required prior to transfer, transshipment on a non-continuous voyage, or disposal in any other country, or to any other end-user of these commodities, either in their original form or after being incorporated into other end-items. An ISO 9001:2008 and DSCC Certified Company 1 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Total Ionizing Dose (TID) Radiation Testing of the RH1499MW Quad Rail-toRail Input and Output Precision C-Load Op Amp for Linear Technology Customer: Linear Technology, PO# 5259J RAD Job Number: 12-370 Part Type Tested: RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp. Traceability Information: Fab Lot Number: W1046927.1, Wafer Number: 1, Assembly Lot Number:656718.1, Date Code: 1203A. See photograph of unit under test in Appendix A. Quantity of Units: 10 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 2 units for control. Serial numbers 284, 303, 314, 331 and 368 were biased during irradiation, serial numbers 404, 445, 474, 500 and 518 were unbiased during irradiation and serial numbers 524 and 558 were used as control. See Appendix B for the radiation bias connection table. Radiation and Electrical Test Increments: 50-300rad(Si)/s ionizing radiation with electrical test increments: pre-irradiation, 10krad(Si), 20krad(Si), 30krad(Si) and 50krad(Si). Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD Overtest and Post-Irradiation Anneal: No overtest. No anneal. Radiation Test Standard: MIL-STD-750E TM1019 and/or MIL-STD-883H TM1019 Condition A. Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS04, Calibration Date: 4/26/2012, Calibration Due: 4/26/2013. LTS2101 Family Board, Entity ID FB10. LTS0600 Test Fixture, Entity ID TF03. RH1499 BGSS-061114 DUT Board. Test Program: RH1499X.SRC Facility and Radiation Source: Aeroflex RAD's Longmire Laboratories, Colorado Springs, CO. Gamma rays provided by JLSA 81-24 Co60 source. Dosimetry performed by Air Ionization Chamber (AIC) traceable to NIST. Aeroflex RAD's dosimetry has been audited by DSCC and Aeroflex RAD has been awarded Laboratory Suitability for MIL-STD-750 and MIL-STD-883 TM 1019. Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and MIL-STD-750. Total Ionizing Dose Test Result: PASSED the total ionizing dose test to the maximum tested dose level of 50krad(Si) with all parameters remaining within their datasheet specifications. An ISO 9001:2008 and DSCC Certified Company 2 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 1.0. Overview and Background It is well known that total dose ionizing radiation can cause parametric degradation and ultimately functional failure in electronic devices. The damage occurs via electron-hole pair production, transport and trapping in the dielectric and interface regions. In discrete devices the bulk of the damage is frequently manifested as a reduction in the gain and/or breakdown voltage of the device. The damage will usually anneal with time following the end of the radiation exposure. Due to this annealing, and to ensure a worst-case test condition MIL-STD-883 TM1019.8 calls out a dose rate of 50 to 300rad(Si)/s as Condition A and further specifies that the time from the end of an incremental radiation exposure and electrical testing shall be 1-hour or less and the total time from the end of one incremental irradiation to the beginning of the next incremental radiation step should be 2-hours or less. The work described in this report was performed to meet MIL-STD-883 TM1019.8 Condition A. 2.0. Radiation Test Apparatus The total ionizing dose testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose (TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead. During the radiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 300rad(Si)/s, determined by the distance from the source. For high-dose rate experiments the bias boards are placed in a radial fashion equidistant from the raised Co-60 rods with the distance adjusted to provide the required dose rate. The irradiator calibration is maintained by Aeroflex RAD Longmire Laboratories using air ionization chamber (AIC) equipment calibrated with traceability to the National Institute of Standards and Technology (NIST). Figure 2.1 shows a photograph of the JLSA 81-24 Co-60 irradiator at Aeroflex RAD's Longmire Laboratory facility. Aeroflex RAD is currently certified by the Defense Supply Center Columbus (DLA) for Laboratory Suitability under MIL STD 750 and MIL-STD-883. Additional details regarding Aeroflex RAD dosimetry for TM1019 Condition A testing are available in Aeroflex RAD's report to DLA entitled: "Dose Rate Mapping of the J.L. Shepherd and Associates Model 81 Irradiator Installed by Radiation Assured Devices". An ISO 9001:2008 and DSCC Certified Company 3 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Figure 2.1. Aeroflex RAD's high dose rate Co-60 irradiator. The dose rate is obtained by positioning the deviceunder-test at a fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately 300rad(Si)/s close to the rods down to 1rad(Si)/s at a distance of approximately 2-feet. An ISO 9001:2008 and DSCC Certified Company 4 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 3.0. Radiation Test Conditions The RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp described in this final report were irradiated using a split 15V supply and with all pins tied to ground, that is biased and unbiased. See the TID Bias Table in Appendix B for the full bias circuits. In our opinion, this bias circuit satisfies the requirements of MIL-STD-883H TM1019.8 Section 3.9.3 Bias and Loading Conditions which states "The bias applied to the test devices shall be selected to produce the greatest radiation induced damage or the worst-case damage for the intended application, if known. While maximum voltage is often worst case some bipolar linear device parameters (e.g. input bias current or maximum output load current) exhibit more degradation with 0 V bias." The devices were irradiated to a maximum total ionizing dose level of 50krad(Si) with incremental readings at 10krad(Si), 20krad(Si) and 30krad(Si). Electrical testing occurred within one hour following the end of each irradiation segment. For intermediate irradiations, the parts were tested and returned to total dose exposure within two hours from the end of the previous radiation increment. The TID bias board was positioned in the Co-60 cell to provide the required minimum of 50rad(Si)/s and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019.8 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1) initially, (2) when the source is changed, or (3) when the orientation or configuration of the source, container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g., a TLD) in the device-irradiation container at the approximate test-device position. If it can be demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors due to dose enhancement, the Pb/Al container may be omitted." The final dose rate within the high dose rate lead-aluminum enclosure was determined using calibration calculations based on air ionization chamber (AIC) dosimetry performed just prior to beginning the total dose irradiations. The final dose rate for this work was 50.34rad(Si)/s with a precision of ±5%. An ISO 9001:2008 and DSCC Certified Company 5 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 4.0. Tested Parameters During the total ionizing dose characterization testing the following electrical parameters were measured pre- and post-irradiation: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. +Supply Current 15V (A) @ VS=+/-15V -Supply Current 15V (A) @ VS=+/-15V Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V An ISO 9001:2008 and DSCC Certified Company 6 TID Report 12-370 130125 R1.1 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. 70. 71. 72. 73. 74. 75. 76. 77. 78. 79. 80. 81. 82. 83. 84. 85. 86. 87. Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V An ISO 9001:2008 and DSCC Certified Company 7 TID Report 12-370 130125 R1.1 88. 89. 90. 91. 92. 93. 94. 95. 96. 97. 98. 99. 100. 101. 102. 103. 104. 105. 106. 107. 108. 109. 110. 111. 112. 113. 114. 115. 116. 117. 118. 119. 120. 121. 122. 123. 124. 125. 126. 127. 128. 129. 130. 131. 132. 133. CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V +Supply Current 5V (A) @ VS=+5V -Supply Current 5V (A) @ VS=+5V Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V An ISO 9001:2008 and DSCC Certified Company 8 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Report 12-370 130125 R1.1 134. 135. 136. 137. 138. 139. 140. 141. 142. 143. 144. 145. 146. 147. 148. 149. 150. 151. 152. 153. 154. 155. 156. 157. 158. 159. 160. 161. 162. 163. 164. 165. 166. 167. 168. 169. 170. 171. 172. 173. 174. 175. 176. 177. 178. 179. Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V +Short-Circuit Current2 1 5V (A) @ VS=+5V +Short-Circuit Current2 2 5V (A) @ VS=+5V +Short-Circuit Current2 3 5V (A) @ VS=+5V An ISO 9001:2008 and DSCC Certified Company 9 TID Report 12-370 130125 R1.1 180. 181. 182. 183. 184. 185. 186. 187. 188. 189. 190. 191. 192. 193. 194. 195. 196. Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 +Short-Circuit Current2 4 5V (A) @ VS=+5V -Short-Circuit Current2 1 5V (A) @ VS=+5V -Short-Circuit Current2 2 5V (A) @ VS=+5V -Short-Circuit Current2 3 5V (A) @ VS=+5V -Short-Circuit Current2 4 5V (A) @ VS=+5V Gain-Bandwidth Product_1 15V (MHz) @ VS=+/-15V, f=100kHz (Unintentionally Omitted) Gain-Bandwidth Product_2 15V (MHz) @ VS=+/-15V, f=100kHz (Unintentionally Omitted) Gain-Bandwidth Product_3 15V (MHz) @ VS=+/-15V, f=100kHz (Unintentionally Omitted) Gain-Bandwidth Product_4 15V (MHz) @ VS=+/-15V, f=100kHz (Unintentionally Omitted) +Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ (Unintentionally Omitted) +Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ (Unintentionally Omitted) +Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ (Unintentionally Omitted) +Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ (Unintentionally Omitted) -Slew Rate_1 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ (Unintentionally Omitted) -Slew Rate_2 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ (Unintentionally Omitted) -Slew Rate_3 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ (Unintentionally Omitted) -Slew Rate_4 15V (V/us) @ VS=+/-15, AV=-1, RL=10kΩ (Unintentionally Omitted) Appendix C details the measured parameters, test conditions, pre-irradiation specification and measurement resolution for each of the measurements. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the total ionizing dose test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. Further, MIL-STD-883H, TM 1019.8 Section 3.13.1.1 Characterization test to determine if a part exhibits ELDRS' states the following: Select a minimum random sample of 21 devices from a population representative of recent production runs. Smaller sample sizes may be used if agreed upon between the parties to the test. All of the selected devices shall have undergone appropriate elevated temperature reliability screens, e.g. burn-in and high temperature storage life. Divide the samples into four groups of 5 each and use the remaining part for a control. Perform pre-irradiation electrical characterization on all parts assuring that they meet the Group A electrical tests. Irradiate 5 samples under a 0 volt bias and another 5 under the irradiation bias given in the acquisition specification at 50300 rad(Si)/s and room temperature. Irradiate 5 samples under a 0 volt bias and another 5 under irradiation bias given in the acquisition specification at < 10mrad(Si)/s and room temperature. Irradiate all samples to the same dose levels, including 0.5 and 1.0 times the anticipated specification dose, and An ISO 9001:2008 and DSCC Certified Company 10 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 repeat the electrical characterization on each part at each dose level. Post irradiation electrical measurements shall be performed per paragraph 3.10 where the low dose rate test is considered Condition D. Calculate the radiation induced change in each electrical parameter (∆para) for each sample at each radiation level. Calculate the ratio of the median ∆para at low dose rate to the median ∆para at high dose rate for each irradiation bias group at each total dose level. If this ratio exceeds 1.5 for any of the most sensitive parameters then the part is considered to be ELDRS susceptible. This test does not apply to parameters which exhibit changes that are within experimental error or whose values are below the pre-irradiation electrical specification limits at low dose rate at the specification dose. Therefore, the data in this report can be analyzed along with the low dose rate report titled "Enhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp for Linear Technology" to demonstrate that these parts do not exhibit ELDRS as defined in the current test method. An ISO 9001:2008 and DSCC Certified Company 11 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 5.0. Total Ionizing Dose Test Results Based on this criterion the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp (from the lot traceability information provided on the first page of this test report) PASSED the total ionizing dose test to the maximum tested dose level of 50krad(Si) with all parameters remaining within their datasheet specifications. Figures 5.1 through 5.184 show plots of all the measured parameters versus total ionizing dose while Tables 5.1 - 5.184 show the corresponding raw data for each of these parameters. In the data plots the solid diamonds are the average of the measured data points for the sample irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the units irradiated with all pins tied to ground. The black lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. The control units, as expected, show no significant changes to any of the parameters. Therefore we can conclude that the electrical testing remained in control throughout the duration of the tests and the observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section to facilitate the location of a particular parameter. An ISO 9001:2008 and DSCC Certified Company 12 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Supply Current 15V (A) @ VS=+/-15V 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.1. Plot of +Supply Current 15V (A) @ VS=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 13 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.1. Raw data for +Supply Current 15V (A) @ VS=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Supply Current 15V (A) @ VS=+/-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 0 7.81E-03 7.71E-03 7.80E-03 7.74E-03 7.79E-03 7.77E-03 7.74E-03 7.70E-03 7.74E-03 7.66E-03 7.91E-03 7.91E-03 Total 10 7.79E-03 7.61E-03 7.72E-03 7.61E-03 7.68E-03 7.74E-03 7.69E-03 7.66E-03 7.70E-03 7.61E-03 7.87E-03 7.88E-03 Dose (krad(Si)) 20 30 7.70E-03 7.68E-03 7.59E-03 7.57E-03 7.71E-03 7.69E-03 7.63E-03 7.61E-03 7.67E-03 7.66E-03 7.74E-03 7.74E-03 7.69E-03 7.69E-03 7.65E-03 7.66E-03 7.69E-03 7.69E-03 7.62E-03 7.62E-03 7.90E-03 7.89E-03 7.89E-03 7.89E-03 50 7.66E-03 7.56E-03 7.67E-03 7.58E-03 7.63E-03 7.73E-03 7.68E-03 7.64E-03 7.68E-03 7.60E-03 7.91E-03 7.90E-03 Biased Statistics Average Biased 7.77E-03 7.68E-03 7.66E-03 7.64E-03 7.62E-03 Std Dev Biased 4.55E-05 7.50E-05 5.03E-05 5.14E-05 5.13E-05 Ps90%/90% (+KTL) Biased 7.89E-03 7.88E-03 7.80E-03 7.78E-03 7.76E-03 Ps90%/90% (-KTL) Biased 7.65E-03 7.47E-03 7.52E-03 7.50E-03 7.48E-03 Un-Biased Statistics Average Un-Biased 7.72E-03 7.68E-03 7.68E-03 7.68E-03 7.66E-03 Std Dev Un-Biased 4.35E-05 4.85E-05 4.47E-05 4.18E-05 4.73E-05 Ps90%/90% (+KTL) Un-Biased 7.84E-03 7.81E-03 7.80E-03 7.79E-03 7.79E-03 Ps90%/90% (-KTL) Un-Biased 7.60E-03 7.55E-03 7.55E-03 7.56E-03 7.53E-03 Specification MAX 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 14 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Supply Current 15V (A) @ VS=+/-15V 0.00E+00 -2.00E-03 -4.00E-03 -6.00E-03 -8.00E-03 -1.00E-02 -1.20E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.2. Plot of -Supply Current 15V (A) @ VS=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 15 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.2. Raw data for -Supply Current 15V (A) @ VS=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Supply Current 15V (A) @ VS=+/-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 0 -7.84E-03 -7.73E-03 -7.83E-03 -7.76E-03 -7.81E-03 -7.79E-03 -7.76E-03 -7.72E-03 -7.76E-03 -7.68E-03 -7.93E-03 -7.93E-03 Biased Statistics Average Biased -7.79E-03 Std Dev Biased 4.65E-05 Ps90%/90% (+KTL) Biased -7.66E-03 Ps90%/90% (-KTL) Biased -7.92E-03 Un-Biased Statistics Average Un-Biased -7.74E-03 Std Dev Un-Biased 4.27E-05 Ps90%/90% (+KTL) Un-Biased -7.63E-03 Ps90%/90% (-KTL) Un-Biased -7.86E-03 Specification MIN -1.00E-02 Status PASS Total 10 -7.81E-03 -7.63E-03 -7.74E-03 -7.63E-03 -7.70E-03 -7.76E-03 -7.71E-03 -7.68E-03 -7.72E-03 -7.63E-03 -7.89E-03 -7.90E-03 Dose (krad(Si)) 20 30 -7.72E-03 -7.70E-03 -7.62E-03 -7.59E-03 -7.74E-03 -7.71E-03 -7.65E-03 -7.63E-03 -7.69E-03 -7.68E-03 -7.76E-03 -7.76E-03 -7.71E-03 -7.71E-03 -7.67E-03 -7.68E-03 -7.71E-03 -7.71E-03 -7.64E-03 -7.65E-03 -7.92E-03 -7.92E-03 -7.92E-03 -7.91E-03 50 -7.69E-03 -7.58E-03 -7.70E-03 -7.60E-03 -7.65E-03 -7.75E-03 -7.69E-03 -7.66E-03 -7.70E-03 -7.62E-03 -7.94E-03 -7.92E-03 -7.70E-03 -7.68E-03 -7.66E-03 -7.64E-03 7.51E-05 5.04E-05 5.19E-05 5.26E-05 -7.49E-03 -7.54E-03 -7.52E-03 -7.50E-03 -7.91E-03 -7.82E-03 -7.80E-03 -7.79E-03 -7.70E-03 4.87E-05 -7.57E-03 -7.83E-03 -1.00E-02 PASS -7.70E-03 4.46E-05 -7.57E-03 -7.82E-03 -1.00E-02 PASS -7.70E-03 4.14E-05 -7.59E-03 -7.81E-03 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 16 -7.68E-03 4.79E-05 -7.55E-03 -7.82E-03 -1.00E-02 PASS Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.3. Plot of Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 17 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.3. Raw data for Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 -3.33E-04 -4.84E-05 -2.31E-04 -8.92E-05 7.58E-05 1.39E-06 -1.66E-04 -2.88E-04 -2.67E-04 -2.53E-04 3.78E-05 -2.53E-04 0 -2.99E-04 -3.48E-05 -2.15E-04 -6.62E-05 9.92E-05 1.27E-05 -1.57E-04 -2.79E-04 -2.50E-04 -2.41E-04 4.15E-05 -2.51E-04 Dose (krad(Si)) 20 30 -3.22E-04 -3.19E-04 -4.55E-05 -4.16E-05 -2.26E-04 -2.25E-04 -8.47E-05 -7.89E-05 7.80E-05 7.65E-05 -2.24E-06 -4.29E-06 -1.73E-04 -1.75E-04 -2.93E-04 -2.96E-04 -2.71E-04 -2.77E-04 -2.57E-04 -2.60E-04 4.15E-05 4.09E-05 -2.51E-04 -2.51E-04 50 -3.13E-04 -4.18E-05 -2.29E-04 -8.14E-05 7.30E-05 -1.13E-05 -1.78E-04 -3.06E-04 -2.82E-04 -2.66E-04 4.24E-05 -2.53E-04 -1.03E-04 -1.25E-04 -1.20E-04 -1.18E-04 -1.18E-04 1.56E-04 1.60E-04 1.57E-04 1.56E-04 1.53E-04 3.25E-04 3.12E-04 3.10E-04 3.10E-04 3.02E-04 -5.32E-04 -5.63E-04 -5.50E-04 -5.45E-04 -5.39E-04 -1.83E-04 1.18E-04 1.42E-04 -5.07E-04 -8.00E-04 PASS 8.00E-04 PASS -1.94E-04 1.19E-04 1.31E-04 -5.20E-04 -9.50E-04 PASS 9.50E-04 PASS -1.99E-04 1.19E-04 1.28E-04 -5.26E-04 -9.50E-04 PASS 9.50E-04 PASS -2.02E-04 1.20E-04 1.27E-04 -5.31E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 18 -2.09E-04 1.20E-04 1.22E-04 -5.39E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.4. Plot of Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 19 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.4. Raw data for Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 -2.88E-05 7.38E-05 -1.17E-04 -1.43E-05 1.15E-05 -2.08E-04 9.69E-05 -2.36E-04 -1.07E-04 -2.77E-04 -8.75E-05 -2.24E-04 0 -7.91E-06 8.40E-05 -1.03E-04 -2.84E-06 4.18E-05 -1.93E-04 1.15E-04 -2.26E-04 -9.58E-05 -2.68E-04 -8.45E-05 -2.24E-04 Dose (krad(Si)) 20 30 -2.64E-05 -2.16E-05 7.94E-05 8.29E-05 -1.10E-04 -1.09E-04 -1.11E-05 -8.15E-06 1.91E-05 2.02E-05 -2.13E-04 -2.16E-04 9.29E-05 9.01E-05 -2.40E-04 -2.43E-04 -1.10E-04 -1.13E-04 -2.81E-04 -2.86E-04 -8.48E-05 -8.57E-05 -2.23E-04 -2.24E-04 50 -1.87E-05 8.44E-05 -1.06E-04 -3.81E-06 1.78E-05 -2.19E-04 8.60E-05 -2.48E-04 -1.17E-04 -2.89E-04 -8.49E-05 -2.24E-04 2.42E-06 -1.49E-05 -9.82E-06 -7.19E-06 -5.26E-06 6.97E-05 6.91E-05 6.92E-05 6.98E-05 6.88E-05 1.94E-04 1.75E-04 1.80E-04 1.84E-04 1.83E-04 -1.89E-04 -2.04E-04 -1.99E-04 -1.99E-04 -1.94E-04 -1.33E-04 1.53E-04 2.86E-04 -5.52E-04 -8.00E-04 PASS 8.00E-04 PASS -1.46E-04 1.50E-04 2.64E-04 -5.57E-04 -9.50E-04 PASS 9.50E-04 PASS -1.50E-04 1.50E-04 2.61E-04 -5.61E-04 -9.50E-04 PASS 9.50E-04 PASS -1.54E-04 1.50E-04 2.59E-04 -5.66E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 20 -1.58E-04 1.50E-04 2.54E-04 -5.69E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.5. Plot of Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 21 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.5. Raw data for Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 4.30E-05 -5.36E-05 8.63E-06 -7.18E-05 1.82E-04 -1.53E-04 -4.53E-05 -2.62E-04 8.59E-05 -1.72E-05 3.08E-06 1.02E-05 0 6.74E-05 -3.33E-05 3.00E-05 -4.64E-05 2.14E-04 -1.39E-04 -3.12E-05 -2.50E-04 9.35E-05 -5.01E-06 6.94E-06 1.38E-05 Dose (krad(Si)) 20 30 2.94E-05 5.05E-05 -5.39E-05 -5.10E-05 1.27E-05 1.21E-05 -6.25E-05 -5.98E-05 1.87E-04 1.88E-04 -1.58E-04 -1.56E-04 -5.31E-05 -5.27E-05 -2.69E-04 -2.69E-04 7.97E-05 7.83E-05 -1.70E-05 -1.54E-05 5.49E-06 6.33E-06 1.20E-05 1.26E-05 50 5.89E-05 -5.11E-05 1.27E-05 -5.71E-05 1.89E-04 -1.60E-04 -5.83E-05 -2.72E-04 7.58E-05 -2.23E-05 6.82E-06 1.44E-05 4.63E-05 2.16E-05 2.25E-05 2.80E-05 3.05E-05 1.05E-04 1.01E-04 1.00E-04 1.00E-04 1.01E-04 3.33E-04 2.98E-04 2.97E-04 3.03E-04 3.07E-04 -2.40E-04 -2.55E-04 -2.52E-04 -2.47E-04 -2.46E-04 -6.63E-05 1.32E-04 2.95E-04 -4.28E-04 -8.00E-04 PASS 8.00E-04 PASS -7.82E-05 1.33E-04 2.87E-04 -4.43E-04 -9.50E-04 PASS 9.50E-04 PASS -8.35E-05 1.34E-04 2.84E-04 -4.51E-04 -9.50E-04 PASS 9.50E-04 PASS -8.30E-05 1.34E-04 2.83E-04 -4.49E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 22 -8.74E-05 1.33E-04 2.78E-04 -4.53E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.6. Plot of Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 23 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.6. Raw data for Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 2.39E-04 -2.05E-04 -1.61E-04 1.83E-04 1.17E-04 -1.90E-05 -1.22E-04 -4.18E-04 -2.26E-04 9.64E-05 1.01E-04 -1.49E-05 0 2.59E-04 -1.89E-04 -1.43E-04 2.07E-04 1.36E-04 -7.43E-06 -1.07E-04 -4.07E-04 -2.11E-04 1.12E-04 1.07E-04 -1.21E-05 Dose (krad(Si)) 20 30 2.42E-04 2.50E-04 -2.02E-04 -1.97E-04 -1.57E-04 -1.58E-04 1.87E-04 1.86E-04 1.22E-04 1.25E-04 -2.20E-05 -2.30E-05 -1.26E-04 -1.29E-04 -4.22E-04 -4.26E-04 -2.28E-04 -2.32E-04 9.47E-05 9.41E-05 1.05E-04 1.04E-04 -1.27E-05 -1.24E-05 50 2.55E-04 -1.96E-04 -1.57E-04 1.87E-04 1.28E-04 -2.60E-05 -1.33E-04 -4.28E-04 -2.36E-04 8.51E-05 1.05E-04 -1.15E-05 5.41E-05 3.45E-05 3.84E-05 4.11E-05 4.32E-05 2.06E-04 2.04E-04 2.04E-04 2.05E-04 2.06E-04 6.19E-04 5.94E-04 5.98E-04 6.04E-04 6.09E-04 -5.11E-04 -5.25E-04 -5.21E-04 -5.22E-04 -5.22E-04 -1.24E-04 1.98E-04 4.19E-04 -6.67E-04 -8.00E-04 PASS 8.00E-04 PASS -1.38E-04 1.97E-04 4.03E-04 -6.79E-04 -9.50E-04 PASS 9.50E-04 PASS -1.41E-04 1.98E-04 4.02E-04 -6.83E-04 -9.50E-04 PASS 9.50E-04 PASS -1.43E-04 1.99E-04 4.03E-04 -6.90E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 24 -1.48E-04 1.97E-04 3.93E-04 -6.89E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.7. Plot of Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 25 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.7. Raw data for Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 -2.59E-09 -1.75E-09 -3.49E-09 -4.20E-09 -1.58E-09 -8.30E-10 -2.96E-09 1.11E-09 -1.21E-09 -1.34E-09 5.10E-10 -1.32E-09 0 -2.24E-09 -1.90E-09 -3.25E-09 -4.63E-09 -1.39E-09 -1.19E-09 -3.21E-09 9.70E-10 -1.08E-09 -1.08E-09 5.10E-10 -1.26E-09 Dose (krad(Si)) 20 30 -2.49E-09 -3.37E-09 -1.22E-09 -9.30E-10 -3.38E-09 -3.78E-09 -4.13E-09 -4.38E-09 -1.74E-09 -2.02E-09 -6.00E-10 -1.03E-09 -2.85E-09 -3.22E-09 1.41E-09 1.56E-09 -1.10E-09 -1.76E-09 -1.83E-09 -1.98E-09 4.80E-10 5.00E-10 -1.31E-09 -1.26E-09 50 -3.12E-09 -1.16E-09 -3.55E-09 -4.32E-09 -1.96E-09 -6.20E-10 -3.50E-09 7.50E-10 -1.50E-09 -1.90E-09 5.10E-10 -1.23E-09 -2.68E-09 -2.72E-09 -2.59E-09 -2.90E-09 -2.82E-09 1.28E-09 1.12E-09 1.18E-09 1.40E-09 1.26E-09 8.38E-10 3.56E-10 6.54E-10 9.43E-10 6.38E-10 -6.20E-09 -5.80E-09 -5.84E-09 -6.74E-09 -6.28E-09 -1.12E-09 1.48E-09 2.94E-09 -5.17E-09 -7.00E-08 PASS 7.00E-08 PASS -1.05E-09 1.46E-09 2.94E-09 -5.04E-09 -1.00E-07 PASS 1.00E-07 PASS -9.94E-10 1.59E-09 3.36E-09 -5.35E-09 -1.00E-07 PASS 1.00E-07 PASS -1.29E-09 1.78E-09 3.58E-09 -6.15E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 26 -1.35E-09 1.57E-09 2.96E-09 -5.67E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.8. Plot of Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 27 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.8. Raw data for Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 1.38E-09 2.88E-09 -6.40E-10 2.00E-10 -1.83E-09 1.47E-09 4.47E-09 -2.24E-09 2.06E-09 -2.66E-09 5.26E-09 1.42E-09 0 1.48E-09 2.59E-09 -7.90E-10 -8.00E-10 -1.43E-09 1.20E-09 4.21E-09 -2.06E-09 2.19E-09 -2.55E-09 5.21E-09 1.39E-09 Dose (krad(Si)) 20 30 1.46E-09 1.02E-09 2.61E-09 2.99E-09 -1.06E-09 -5.80E-10 6.00E-11 1.60E-10 -1.73E-09 -1.33E-09 2.10E-09 1.94E-09 4.55E-09 5.07E-09 -2.07E-09 -2.56E-09 1.99E-09 1.36E-09 -2.72E-09 -2.79E-09 5.17E-09 5.23E-09 1.49E-09 1.49E-09 50 1.53E-09 3.12E-09 -4.00E-10 1.00E-11 -1.28E-09 2.14E-09 4.54E-09 -2.60E-09 1.55E-09 -3.23E-09 5.14E-09 1.46E-09 2.10E-10 3.98E-10 2.68E-10 4.52E-10 5.96E-10 1.73E-09 1.82E-09 1.78E-09 1.67E-09 1.74E-09 4.96E-09 5.38E-09 5.15E-09 5.02E-09 5.36E-09 -4.54E-09 -4.58E-09 -4.62E-09 -4.11E-09 -4.17E-09 5.98E-10 2.87E-09 8.46E-09 -7.27E-09 -7.00E-08 PASS 7.00E-08 PASS 6.20E-10 3.02E-09 8.91E-09 -7.67E-09 -1.00E-07 PASS 1.00E-07 PASS 7.70E-10 3.07E-09 9.20E-09 -7.66E-09 -1.00E-07 PASS 1.00E-07 PASS 6.04E-10 3.31E-09 9.68E-09 -8.47E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 28 4.80E-10 3.30E-09 9.54E-09 -8.58E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.9. Plot of Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 29 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.9. Raw data for Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 1.73E-09 1.30E-09 1.52E-09 1.64E-09 -2.75E-09 -2.59E-09 -2.75E-09 -2.68E-09 1.40E-10 8.00E-11 2.10E-10 3.30E-10 2.81E-09 2.76E-09 2.88E-09 3.09E-09 4.31E-09 3.80E-09 4.35E-09 4.05E-09 2.18E-09 2.27E-09 2.22E-09 2.27E-09 -1.77E-09 -2.23E-09 -1.92E-09 -1.72E-09 -3.47E-09 -3.41E-09 -3.68E-09 -2.97E-09 2.18E-09 2.48E-09 1.96E-09 2.39E-09 4.27E-09 4.11E-09 4.35E-09 4.80E-09 8.80E-10 9.40E-10 8.50E-10 9.20E-10 2.34E-09 2.42E-09 2.43E-09 2.40E-09 50 2.36E-09 -2.42E-09 -1.50E-10 2.70E-09 4.51E-09 2.10E-09 -2.05E-09 -3.96E-09 1.64E-09 4.48E-09 9.30E-10 2.35E-09 1.25E-09 1.07E-09 1.24E-09 1.29E-09 1.40E-09 2.70E-09 2.49E-09 2.71E-09 2.63E-09 2.71E-09 8.66E-09 7.89E-09 8.68E-09 8.50E-09 8.82E-09 -6.17E-09 -5.75E-09 -6.19E-09 -5.92E-09 -6.02E-09 6.78E-10 3.19E-09 9.42E-09 -8.06E-09 -7.00E-08 PASS 7.00E-08 PASS 6.44E-10 3.27E-09 9.61E-09 -8.32E-09 -1.00E-07 PASS 1.00E-07 PASS 5.86E-10 3.29E-09 9.60E-09 -8.43E-09 -1.00E-07 PASS 1.00E-07 PASS 9.54E-10 3.21E-09 9.75E-09 -7.84E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 30 4.42E-10 3.39E-09 9.75E-09 -8.86E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.10. Plot of Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 31 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.10. Raw data for Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 4.00E-09 3.70E-09 1.41E-09 1.60E-09 7.17E-09 1.30E-09 -3.27E-09 -1.10E-09 -2.89E-09 3.30E-10 -8.90E-10 3.21E-09 0 3.84E-09 3.85E-09 1.26E-09 1.88E-09 7.38E-09 1.29E-09 -3.41E-09 -7.00E-10 -3.24E-09 -1.20E-10 -8.70E-10 3.20E-09 Dose (krad(Si)) 20 30 50 4.21E-09 3.86E-09 4.85E-09 3.89E-09 4.05E-09 4.26E-09 1.96E-09 1.81E-09 2.21E-09 1.57E-09 2.00E-09 2.05E-09 6.96E-09 6.87E-09 7.46E-09 2.03E-09 2.06E-09 2.76E-09 -2.90E-09 -2.87E-09 -2.41E-09 -6.60E-10 -9.20E-10 2.20E-10 -3.03E-09 -3.26E-09 -3.70E-09 2.10E-10 8.20E-10 9.50E-10 -8.90E-10 -9.00E-10 -9.00E-10 3.18E-09 3.21E-09 3.22E-09 3.64E-09 3.58E-09 3.72E-09 3.72E-09 4.17E-09 2.39E-09 2.33E-09 2.15E-09 2.04E-09 2.22E-09 1.02E-08 9.96E-09 9.61E-09 9.31E-09 1.02E-08 -2.91E-09 -2.81E-09 -2.18E-09 -1.88E-09 -1.91E-09 -1.24E-09 2.04E-09 4.36E-09 -6.83E-09 -7.00E-08 PASS 7.00E-08 PASS -1.13E-09 1.98E-09 4.31E-09 -6.56E-09 -1.00E-07 PASS 1.00E-07 PASS -8.70E-10 2.15E-09 5.01E-09 -6.75E-09 -1.00E-07 PASS 1.00E-07 PASS -8.34E-10 2.30E-09 5.47E-09 -7.14E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 32 -4.36E-10 2.60E-09 6.70E-09 -7.58E-09 -1.00E-07 PASS 1.00E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.11. Plot of +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 33 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.11. Raw data for +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.98E-07 -3.14E-07 -3.06E-07 -3.30E-07 -2.91E-07 -3.00E-07 -2.72E-07 -3.19E-07 -3.29E-07 -3.04E-07 -3.15E-07 -2.82E-07 Total 10 -3.02E-07 -3.21E-07 -3.13E-07 -3.43E-07 -2.99E-07 -3.06E-07 -2.79E-07 -3.25E-07 -3.36E-07 -3.12E-07 -3.17E-07 -2.84E-07 Dose (krad(Si)) 20 30 -3.10E-07 -3.15E-07 -3.24E-07 -3.28E-07 -3.16E-07 -3.21E-07 -3.44E-07 -3.47E-07 -3.03E-07 -3.06E-07 -3.10E-07 -3.14E-07 -2.84E-07 -2.88E-07 -3.31E-07 -3.33E-07 -3.41E-07 -3.49E-07 -3.16E-07 -3.20E-07 -3.15E-07 -3.16E-07 -2.83E-07 -2.83E-07 50 -3.21E-07 -3.33E-07 -3.27E-07 -3.57E-07 -3.12E-07 -3.21E-07 -2.96E-07 -3.45E-07 -3.59E-07 -3.29E-07 -3.14E-07 -2.83E-07 -3.08E-07 -3.16E-07 -3.19E-07 -3.23E-07 -3.30E-07 1.50E-08 1.77E-08 1.59E-08 1.55E-08 1.66E-08 -2.67E-07 -2.67E-07 -2.76E-07 -2.81E-07 -2.84E-07 -3.49E-07 -3.64E-07 -3.63E-07 -3.66E-07 -3.76E-07 -3.05E-07 2.17E-08 -2.45E-07 -3.64E-07 -7.15E-07 PASS 7.15E-07 PASS -3.12E-07 2.14E-08 -2.53E-07 -3.70E-07 -7.65E-07 PASS 7.65E-07 PASS -3.17E-07 2.16E-08 -2.57E-07 -3.76E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 34 -3.21E-07 2.27E-08 -2.59E-07 -3.83E-07 -8.15E-07 PASS 8.15E-07 PASS -3.30E-07 2.37E-08 -2.65E-07 -3.95E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.12. Plot of +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 35 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.12. Raw data for +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.97E-07 -3.10E-07 -3.07E-07 -3.20E-07 -2.81E-07 -2.83E-07 -2.76E-07 -3.18E-07 -3.18E-07 -3.02E-07 -2.99E-07 -2.88E-07 Total 10 -3.01E-07 -3.18E-07 -3.14E-07 -3.31E-07 -2.90E-07 -2.90E-07 -2.84E-07 -3.25E-07 -3.25E-07 -3.10E-07 -3.01E-07 -2.90E-07 Dose (krad(Si)) 20 30 -3.10E-07 -3.15E-07 -3.22E-07 -3.25E-07 -3.17E-07 -3.22E-07 -3.29E-07 -3.34E-07 -2.93E-07 -2.97E-07 -2.94E-07 -2.98E-07 -2.89E-07 -2.92E-07 -3.30E-07 -3.34E-07 -3.31E-07 -3.35E-07 -3.14E-07 -3.18E-07 -2.99E-07 -2.99E-07 -2.89E-07 -2.89E-07 50 -3.22E-07 -3.31E-07 -3.29E-07 -3.40E-07 -3.04E-07 -3.05E-07 -3.00E-07 -3.47E-07 -3.49E-07 -3.26E-07 -2.98E-07 -2.88E-07 -3.03E-07 -3.11E-07 -3.14E-07 -3.19E-07 -3.25E-07 1.46E-08 1.56E-08 1.37E-08 1.40E-08 1.37E-08 -2.63E-07 -2.68E-07 -2.77E-07 -2.80E-07 -2.87E-07 -3.43E-07 -3.54E-07 -3.52E-07 -3.57E-07 -3.63E-07 -3.00E-07 1.94E-08 -2.46E-07 -3.53E-07 -7.15E-07 PASS 7.15E-07 PASS -3.07E-07 1.94E-08 -2.54E-07 -3.60E-07 -7.65E-07 PASS 7.65E-07 PASS -3.12E-07 1.97E-08 -2.58E-07 -3.66E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 36 -3.15E-07 1.99E-08 -2.61E-07 -3.70E-07 -8.15E-07 PASS 8.15E-07 PASS -3.26E-07 2.27E-08 -2.63E-07 -3.88E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.13. Plot of +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 37 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.13. Raw data for +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.98E-07 -3.14E-07 -3.04E-07 -3.19E-07 -2.79E-07 -2.78E-07 -2.80E-07 -3.24E-07 -3.13E-07 -2.99E-07 -3.02E-07 -2.86E-07 Total 10 -3.02E-07 -3.21E-07 -3.11E-07 -3.31E-07 -2.88E-07 -2.85E-07 -2.88E-07 -3.31E-07 -3.20E-07 -3.07E-07 -3.04E-07 -2.88E-07 Dose (krad(Si)) 20 30 -3.10E-07 -3.15E-07 -3.25E-07 -3.29E-07 -3.14E-07 -3.18E-07 -3.30E-07 -3.33E-07 -2.92E-07 -2.95E-07 -2.90E-07 -2.93E-07 -2.92E-07 -2.97E-07 -3.36E-07 -3.39E-07 -3.26E-07 -3.30E-07 -3.11E-07 -3.14E-07 -3.02E-07 -3.02E-07 -2.87E-07 -2.87E-07 50 -3.22E-07 -3.35E-07 -3.23E-07 -3.40E-07 -3.02E-07 -3.01E-07 -3.05E-07 -3.53E-07 -3.39E-07 -3.23E-07 -3.01E-07 -2.86E-07 -3.03E-07 -3.11E-07 -3.14E-07 -3.18E-07 -3.24E-07 1.55E-08 1.64E-08 1.48E-08 1.49E-08 1.46E-08 -2.60E-07 -2.66E-07 -2.73E-07 -2.77E-07 -2.84E-07 -3.45E-07 -3.56E-07 -3.55E-07 -3.59E-07 -3.65E-07 -2.99E-07 2.01E-08 -2.44E-07 -3.54E-07 -7.15E-07 PASS 7.15E-07 PASS -3.06E-07 2.00E-08 -2.51E-07 -3.61E-07 -7.65E-07 PASS 7.65E-07 PASS -3.11E-07 2.04E-08 -2.55E-07 -3.67E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 38 -3.14E-07 1.99E-08 -2.60E-07 -3.69E-07 -8.15E-07 PASS 8.15E-07 PASS -3.24E-07 2.21E-08 -2.64E-07 -3.85E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.14. Plot of +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 39 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.14. Raw data for +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.89E-07 -3.14E-07 -3.05E-07 -3.29E-07 -2.93E-07 -2.98E-07 -2.74E-07 -3.23E-07 -3.25E-07 -3.04E-07 -3.15E-07 -2.73E-07 Total 10 -2.93E-07 -3.21E-07 -3.12E-07 -3.43E-07 -3.03E-07 -3.05E-07 -2.82E-07 -3.30E-07 -3.31E-07 -3.11E-07 -3.17E-07 -2.75E-07 Dose (krad(Si)) 20 30 -3.01E-07 -3.06E-07 -3.25E-07 -3.29E-07 -3.15E-07 -3.19E-07 -3.40E-07 -3.47E-07 -3.07E-07 -3.11E-07 -3.10E-07 -3.14E-07 -2.86E-07 -2.90E-07 -3.35E-07 -3.38E-07 -3.36E-07 -3.39E-07 -3.15E-07 -3.18E-07 -3.15E-07 -3.15E-07 -2.74E-07 -2.74E-07 50 -3.12E-07 -3.34E-07 -3.25E-07 -3.55E-07 -3.19E-07 -3.22E-07 -2.98E-07 -3.49E-07 -3.52E-07 -3.26E-07 -3.14E-07 -2.73E-07 -3.06E-07 -3.14E-07 -3.17E-07 -3.23E-07 -3.29E-07 1.60E-08 1.89E-08 1.54E-08 1.63E-08 1.66E-08 -2.62E-07 -2.62E-07 -2.75E-07 -2.78E-07 -2.83E-07 -3.50E-07 -3.66E-07 -3.60E-07 -3.67E-07 -3.75E-07 -3.05E-07 2.05E-08 -2.48E-07 -3.61E-07 -7.15E-07 PASS 7.15E-07 PASS -3.12E-07 2.02E-08 -2.56E-07 -3.67E-07 -7.65E-07 PASS 7.65E-07 PASS -3.16E-07 2.05E-08 -2.60E-07 -3.73E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 40 -3.20E-07 2.02E-08 -2.64E-07 -3.75E-07 -8.15E-07 PASS 8.15E-07 PASS -3.29E-07 2.22E-08 -2.69E-07 -3.90E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.15. Plot of -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 41 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.15. Raw data for -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.95E-07 -3.11E-07 -3.02E-07 -3.25E-07 -2.89E-07 -2.98E-07 -2.68E-07 -3.19E-07 -3.27E-07 -3.02E-07 -3.15E-07 -2.81E-07 Total 10 -2.99E-07 -3.18E-07 -3.09E-07 -3.38E-07 -2.97E-07 -3.04E-07 -2.76E-07 -3.26E-07 -3.34E-07 -3.10E-07 -3.17E-07 -2.83E-07 Dose (krad(Si)) 20 30 -3.07E-07 -3.11E-07 -3.22E-07 -3.26E-07 -3.12E-07 -3.17E-07 -3.37E-07 -3.40E-07 -3.00E-07 -3.04E-07 -3.09E-07 -3.13E-07 -2.81E-07 -2.84E-07 -3.31E-07 -3.34E-07 -3.39E-07 -3.47E-07 -3.14E-07 -3.18E-07 -3.15E-07 -3.15E-07 -2.81E-07 -2.82E-07 50 -3.18E-07 -3.31E-07 -3.23E-07 -3.53E-07 -3.10E-07 -3.20E-07 -2.93E-07 -3.41E-07 -3.56E-07 -3.26E-07 -3.14E-07 -2.81E-07 -3.04E-07 -3.12E-07 -3.16E-07 -3.20E-07 -3.27E-07 1.40E-08 1.66E-08 1.42E-08 1.43E-08 1.64E-08 -2.66E-07 -2.67E-07 -2.77E-07 -2.80E-07 -2.82E-07 -3.43E-07 -3.58E-07 -3.55E-07 -3.59E-07 -3.72E-07 -3.03E-07 2.28E-08 -2.40E-07 -3.66E-07 -7.15E-07 PASS 7.15E-07 PASS -3.10E-07 2.24E-08 -2.48E-07 -3.71E-07 -7.65E-07 PASS 7.65E-07 PASS -3.15E-07 2.26E-08 -2.53E-07 -3.77E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 42 -3.19E-07 2.38E-08 -2.54E-07 -3.84E-07 -8.15E-07 PASS 8.15E-07 PASS -3.27E-07 2.38E-08 -2.62E-07 -3.92E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.16. Plot of -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 43 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.16. Raw data for -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.98E-07 -3.13E-07 -3.05E-07 -3.18E-07 -2.79E-07 -2.84E-07 -2.80E-07 -3.16E-07 -3.19E-07 -3.00E-07 -3.03E-07 -2.89E-07 Total 10 -3.02E-07 -3.20E-07 -3.13E-07 -3.31E-07 -2.88E-07 -2.91E-07 -2.88E-07 -3.23E-07 -3.27E-07 -3.07E-07 -3.05E-07 -2.91E-07 Dose (krad(Si)) 20 30 -3.11E-07 -3.15E-07 -3.24E-07 -3.28E-07 -3.16E-07 -3.21E-07 -3.29E-07 -3.34E-07 -2.91E-07 -2.95E-07 -2.95E-07 -2.99E-07 -2.93E-07 -2.97E-07 -3.28E-07 -3.31E-07 -3.32E-07 -3.35E-07 -3.11E-07 -3.15E-07 -3.04E-07 -3.04E-07 -2.90E-07 -2.90E-07 50 -3.23E-07 -3.34E-07 -3.28E-07 -3.40E-07 -3.02E-07 -3.07E-07 -3.04E-07 -3.39E-07 -3.49E-07 -3.23E-07 -3.03E-07 -2.89E-07 -3.03E-07 -3.11E-07 -3.14E-07 -3.19E-07 -3.25E-07 1.51E-08 1.63E-08 1.47E-08 1.48E-08 1.45E-08 -2.61E-07 -2.66E-07 -2.74E-07 -2.78E-07 -2.86E-07 -3.44E-07 -3.55E-07 -3.55E-07 -3.59E-07 -3.65E-07 -3.00E-07 1.79E-08 -2.51E-07 -3.49E-07 -7.15E-07 PASS 7.15E-07 PASS -3.07E-07 1.77E-08 -2.58E-07 -3.56E-07 -7.65E-07 PASS 7.65E-07 PASS -3.12E-07 1.81E-08 -2.62E-07 -3.61E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 44 -3.15E-07 1.77E-08 -2.67E-07 -3.64E-07 -8.15E-07 PASS 8.15E-07 PASS -3.24E-07 1.94E-08 -2.71E-07 -3.77E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.17. Plot of -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 45 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.17. Raw data for -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.99E-07 -3.11E-07 -3.04E-07 -3.21E-07 -2.83E-07 -2.80E-07 -2.77E-07 -3.20E-07 -3.15E-07 -3.03E-07 -3.02E-07 -2.88E-07 Total 10 -3.03E-07 -3.18E-07 -3.11E-07 -3.33E-07 -2.92E-07 -2.87E-07 -2.85E-07 -3.27E-07 -3.22E-07 -3.11E-07 -3.04E-07 -2.90E-07 Dose (krad(Si)) 20 30 -3.11E-07 -3.16E-07 -3.22E-07 -3.26E-07 -3.13E-07 -3.18E-07 -3.32E-07 -3.36E-07 -2.95E-07 -2.99E-07 -2.91E-07 -2.95E-07 -2.90E-07 -2.94E-07 -3.32E-07 -3.35E-07 -3.27E-07 -3.31E-07 -3.15E-07 -3.19E-07 -3.02E-07 -3.03E-07 -2.89E-07 -2.89E-07 50 -3.24E-07 -3.32E-07 -3.23E-07 -3.45E-07 -3.06E-07 -3.03E-07 -3.03E-07 -3.48E-07 -3.40E-07 -3.27E-07 -3.02E-07 -2.88E-07 -3.04E-07 -3.11E-07 -3.15E-07 -3.19E-07 -3.26E-07 1.42E-08 1.56E-08 1.36E-08 1.36E-08 1.43E-08 -2.65E-07 -2.69E-07 -2.78E-07 -2.82E-07 -2.87E-07 -3.43E-07 -3.54E-07 -3.52E-07 -3.56E-07 -3.65E-07 -2.99E-07 1.96E-08 -2.45E-07 -3.53E-07 -7.15E-07 PASS 7.15E-07 PASS -3.06E-07 1.95E-08 -2.53E-07 -3.60E-07 -7.65E-07 PASS 7.65E-07 PASS -3.11E-07 1.96E-08 -2.57E-07 -3.65E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 46 -3.15E-07 1.94E-08 -2.62E-07 -3.68E-07 -8.15E-07 PASS 8.15E-07 PASS -3.24E-07 2.07E-08 -2.67E-07 -3.81E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.18. Plot of -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 47 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.18. Raw data for -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.93E-07 -3.17E-07 -3.05E-07 -3.30E-07 -3.00E-07 -2.99E-07 -2.70E-07 -3.21E-07 -3.21E-07 -3.04E-07 -3.13E-07 -2.76E-07 Total 10 -2.97E-07 -3.25E-07 -3.13E-07 -3.46E-07 -3.09E-07 -3.06E-07 -2.78E-07 -3.28E-07 -3.28E-07 -3.11E-07 -3.16E-07 -2.78E-07 Dose (krad(Si)) 20 30 -3.05E-07 -3.10E-07 -3.28E-07 -3.32E-07 -3.16E-07 -3.21E-07 -3.41E-07 -3.48E-07 -3.13E-07 -3.17E-07 -3.11E-07 -3.16E-07 -2.83E-07 -2.87E-07 -3.33E-07 -3.36E-07 -3.33E-07 -3.36E-07 -3.15E-07 -3.18E-07 -3.14E-07 -3.14E-07 -2.76E-07 -2.77E-07 50 -3.17E-07 -3.38E-07 -3.27E-07 -3.58E-07 -3.26E-07 -3.24E-07 -2.95E-07 -3.48E-07 -3.48E-07 -3.27E-07 -3.13E-07 -2.76E-07 -3.09E-07 -3.18E-07 -3.21E-07 -3.26E-07 -3.33E-07 1.48E-08 1.84E-08 1.41E-08 1.50E-08 1.57E-08 -2.68E-07 -2.68E-07 -2.82E-07 -2.84E-07 -2.90E-07 -3.50E-07 -3.68E-07 -3.59E-07 -3.67E-07 -3.76E-07 -3.03E-07 2.09E-08 -2.46E-07 -3.60E-07 -7.15E-07 PASS 7.15E-07 PASS -3.10E-07 2.04E-08 -2.54E-07 -3.66E-07 -7.65E-07 PASS 7.65E-07 PASS -3.15E-07 2.05E-08 -2.59E-07 -3.71E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 48 -3.19E-07 2.02E-08 -2.63E-07 -3.74E-07 -8.15E-07 PASS 8.15E-07 PASS -3.28E-07 2.21E-08 -2.68E-07 -3.89E-07 -8.65E-07 PASS 8.65E-07 PASS Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.19. Plot of Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 49 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.19. Raw data for Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 -1.17E-04 5.49E-06 -5.36E-05 1.45E-04 2.21E-04 2.42E-04 -5.50E-07 -2.37E-04 -1.19E-04 7.73E-05 1.32E-04 6.09E-06 0 -9.80E-05 1.62E-05 -4.28E-05 1.61E-04 2.43E-04 2.48E-04 6.33E-06 -2.30E-04 -1.05E-04 8.81E-05 1.34E-04 6.82E-06 Dose (krad(Si)) 20 30 -1.09E-04 -1.06E-04 6.70E-06 1.08E-05 -4.82E-05 -4.49E-05 1.48E-04 1.54E-04 2.26E-04 2.26E-04 2.40E-04 2.38E-04 -2.84E-06 -5.13E-06 -2.41E-04 -2.44E-04 -1.21E-04 -1.24E-04 7.60E-05 7.47E-05 1.34E-04 1.33E-04 6.57E-06 7.18E-06 50 -1.01E-04 1.03E-05 -4.49E-05 1.54E-04 2.25E-04 2.33E-04 -4.53E-06 -2.50E-04 -1.28E-04 6.94E-05 1.34E-04 8.02E-06 5.59E-05 4.02E-05 4.49E-05 4.80E-05 4.86E-05 1.42E-04 1.40E-04 1.39E-04 1.38E-04 1.37E-04 4.46E-04 4.24E-04 4.26E-04 4.27E-04 4.24E-04 -3.35E-04 -3.44E-04 -3.36E-04 -3.31E-04 -3.26E-04 1.46E-06 1.82E-04 5.01E-04 -4.98E-04 -8.00E-04 PASS 8.00E-04 PASS -7.38E-06 1.83E-04 4.95E-04 -5.10E-04 -9.50E-04 PASS 9.50E-04 PASS -9.72E-06 1.84E-04 4.95E-04 -5.15E-04 -9.50E-04 PASS 9.50E-04 PASS -1.21E-05 1.85E-04 4.95E-04 -5.19E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 50 -1.58E-05 1.85E-04 4.91E-04 -5.23E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.20. Plot of Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 51 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.20. Raw data for Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 1.34E-04 3.03E-04 -2.92E-05 1.23E-04 5.75E-05 -8.88E-05 2.60E-04 -3.16E-05 1.20E-04 -1.53E-05 9.82E-05 4.11E-05 0 1.53E-04 3.16E-04 -1.88E-05 1.36E-04 8.28E-05 -7.50E-05 2.74E-04 -2.31E-05 1.30E-04 -7.67E-06 1.01E-04 4.05E-05 Dose (krad(Si)) 20 30 1.39E-04 1.46E-04 3.07E-04 3.11E-04 -2.37E-05 -2.20E-05 1.27E-04 1.31E-04 6.49E-05 6.47E-05 -9.30E-05 -9.53E-05 2.59E-04 2.57E-04 -3.38E-05 -3.70E-05 1.20E-04 1.19E-04 -1.53E-05 -1.77E-05 1.01E-04 9.98E-05 4.21E-05 4.15E-05 50 1.49E-04 3.13E-04 -1.90E-05 1.37E-04 6.50E-05 -9.99E-05 2.56E-04 -4.08E-05 1.16E-04 -2.05E-05 1.00E-04 4.18E-05 1.34E-04 1.18E-04 1.23E-04 1.26E-04 1.29E-04 1.22E-04 1.22E-04 1.22E-04 1.23E-04 1.23E-04 4.68E-04 4.53E-04 4.56E-04 4.63E-04 4.66E-04 -2.01E-04 -2.17E-04 -2.11E-04 -2.11E-04 -2.08E-04 5.96E-05 1.42E-04 4.48E-04 -3.29E-04 -8.00E-04 PASS 8.00E-04 PASS 4.88E-05 1.41E-04 4.34E-04 -3.37E-04 -9.50E-04 PASS 9.50E-04 PASS 4.73E-05 1.42E-04 4.35E-04 -3.41E-04 -9.50E-04 PASS 9.50E-04 PASS 4.51E-05 1.42E-04 4.34E-04 -3.44E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 52 4.23E-05 1.43E-04 4.36E-04 -3.51E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.21. Plot of Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 53 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.21. Raw data for Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 2.01E-04 1.82E-04 2.03E-04 1.89E-04 2.00E-04 1.43E-04 1.28E-04 1.32E-04 1.35E-04 1.35E-04 1.09E-04 9.64E-05 1.04E-04 1.03E-04 1.05E-04 2.19E-04 2.12E-04 2.05E-04 2.08E-04 2.12E-04 2.18E-04 1.90E-04 1.98E-04 1.96E-04 1.97E-04 -1.61E-04 -1.72E-04 -1.74E-04 -1.77E-04 -1.79E-04 6.04E-05 5.17E-05 5.15E-05 4.41E-05 4.07E-05 4.98E-05 3.97E-05 3.74E-05 3.25E-05 3.04E-05 -1.52E-05 -2.13E-05 -2.20E-05 -2.74E-05 -2.84E-05 1.91E-04 1.82E-04 1.83E-04 1.83E-04 1.78E-04 2.57E-04 2.60E-04 2.58E-04 2.55E-04 2.55E-04 1.62E-04 1.63E-04 1.61E-04 1.61E-04 1.61E-04 1.78E-04 4.91E-05 3.13E-04 4.33E-05 1.62E-04 4.80E-05 2.93E-04 3.01E-05 1.68E-04 4.73E-05 2.98E-04 3.88E-05 1.66E-04 4.51E-05 2.90E-04 4.26E-05 1.70E-04 4.70E-05 2.99E-04 4.06E-05 2.50E-05 1.28E-04 3.75E-04 -3.25E-04 -8.00E-04 PASS 8.00E-04 PASS 1.61E-05 1.28E-04 3.68E-04 -3.36E-04 -9.50E-04 PASS 9.50E-04 PASS 1.52E-05 1.30E-04 3.71E-04 -3.40E-04 -9.50E-04 PASS 9.50E-04 PASS 1.10E-05 1.30E-04 3.68E-04 -3.46E-04 -9.50E-04 PASS 9.50E-04 PASS 8.36E-06 1.29E-04 3.62E-04 -3.45E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 54 Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.22. Plot of Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 55 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.22. Raw data for Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 4.08E-04 3.88E-04 3.95E-04 4.01E-04 4.09E-04 7.50E-05 5.48E-05 5.63E-05 5.81E-05 5.90E-05 8.18E-05 6.47E-05 6.98E-05 6.88E-05 7.01E-05 2.11E-04 1.88E-04 1.92E-04 1.93E-04 1.93E-04 2.12E-04 1.94E-04 1.98E-04 2.01E-04 2.02E-04 3.40E-04 3.32E-04 3.30E-04 3.28E-04 3.26E-04 -1.15E-04 -1.28E-04 -1.32E-04 -1.34E-04 -1.36E-04 -1.98E-04 -2.08E-04 -2.12E-04 -2.15E-04 -2.15E-04 -5.61E-05 -7.20E-05 -7.37E-05 -7.50E-05 -7.72E-05 2.22E-04 2.09E-04 2.09E-04 2.07E-04 2.01E-04 3.27E-05 2.99E-05 3.19E-05 3.08E-05 3.08E-05 1.87E-04 1.85E-04 1.87E-04 1.87E-04 1.87E-04 1.98E-04 1.78E-04 1.82E-04 1.84E-04 1.87E-04 1.35E-04 1.35E-04 1.36E-04 1.38E-04 1.41E-04 5.68E-04 5.48E-04 5.55E-04 5.64E-04 5.73E-04 -1.73E-04 -1.92E-04 -1.91E-04 -1.95E-04 -2.00E-04 3.85E-05 2.31E-04 6.72E-04 -5.95E-04 -8.00E-04 PASS 8.00E-04 PASS 2.65E-05 2.32E-04 6.63E-04 -6.10E-04 -9.50E-04 PASS 9.50E-04 PASS 2.41E-05 2.33E-04 6.63E-04 -6.14E-04 -9.50E-04 PASS 9.50E-04 PASS 2.23E-05 2.33E-04 6.62E-04 -6.17E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 56 1.96E-05 2.32E-04 6.56E-04 -6.17E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.23. Plot of Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 57 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.23. Raw data for Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 -7.09E-09 -8.65E-09 -1.70E-09 -1.60E-10 -7.13E-09 9.38E-09 3.40E-10 -4.50E-09 1.40E-08 2.03E-09 1.02E-09 2.45E-09 0 -9.13E-09 -8.51E-09 -1.50E-09 1.18E-09 -7.29E-09 8.73E-09 5.90E-10 -4.48E-09 1.30E-08 2.60E-09 1.02E-09 2.15E-09 Dose (krad(Si)) 20 30 -5.16E-09 -5.69E-09 -9.41E-09 -9.72E-09 -7.70E-10 -6.00E-11 9.00E-10 1.05E-09 -7.73E-09 -7.72E-09 9.10E-09 8.71E-09 9.10E-10 1.23E-09 -4.71E-09 -4.96E-09 1.47E-08 1.40E-08 2.81E-09 3.11E-09 1.12E-09 1.09E-09 2.09E-09 2.29E-09 50 -5.33E-09 -1.02E-08 1.10E-10 1.08E-09 -8.23E-09 8.24E-09 1.42E-09 -4.91E-09 1.50E-08 3.59E-09 1.17E-09 2.44E-09 -5.05E-09 -4.95E-09 -4.43E-09 -4.43E-09 -4.51E-09 4.61E-09 3.76E-09 4.42E-09 4.73E-09 4.98E-09 7.59E-09 5.36E-09 7.68E-09 8.54E-09 9.14E-09 -1.77E-08 -1.53E-08 -1.65E-08 -1.74E-08 -1.82E-08 4.08E-09 6.86E-09 2.29E-08 -1.47E-08 -7.00E-08 PASS 7.00E-08 PASS 4.25E-09 7.38E-09 2.45E-08 -1.60E-08 -1.00E-07 PASS 1.00E-07 PASS 4.55E-09 7.50E-09 2.51E-08 -1.60E-08 -1.00E-07 PASS 1.00E-07 PASS 4.42E-09 7.24E-09 2.43E-08 -1.54E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 58 4.67E-09 7.47E-09 2.52E-08 -1.58E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.24. Plot of Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 59 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.24. Raw data for Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 1.93E-09 3.79E-09 4.64E-09 4.44E-09 4.85E-09 1.01E-09 8.50E-10 1.09E-09 9.70E-10 4.80E-10 8.21E-09 8.32E-09 7.80E-09 7.40E-09 6.88E-09 -4.00E-11 -1.05E-09 -6.00E-11 1.00E-11 1.57E-09 5.02E-09 4.86E-09 5.07E-09 5.01E-09 5.08E-09 -1.56E-09 -1.03E-09 -3.70E-10 -2.00E-11 -1.10E-10 1.07E-08 1.09E-08 1.23E-08 1.37E-08 1.46E-08 9.90E-10 9.00E-10 1.38E-09 7.50E-10 2.50E-10 5.65E-09 6.18E-09 7.62E-09 8.70E-09 9.23E-09 4.71E-09 4.86E-09 5.14E-09 5.94E-09 6.23E-09 5.89E-09 6.21E-09 6.11E-09 6.01E-09 5.96E-09 -4.90E-10 -5.60E-10 -4.80E-10 -5.90E-10 -5.60E-10 3.23E-09 3.35E-09 3.71E-09 3.57E-09 3.77E-09 3.37E-09 3.63E-09 3.18E-09 3.04E-09 2.66E-09 1.25E-08 1.33E-08 1.24E-08 1.19E-08 1.11E-08 -6.00E-09 -6.61E-09 -5.02E-09 -4.77E-09 -3.51E-09 4.10E-09 4.69E-09 1.70E-08 -8.77E-09 -7.00E-08 PASS 7.00E-08 PASS 4.37E-09 4.68E-09 1.72E-08 -8.47E-09 -1.00E-07 PASS 1.00E-07 PASS 5.22E-09 5.06E-09 1.91E-08 -8.66E-09 -1.00E-07 PASS 1.00E-07 PASS 5.81E-09 5.70E-09 2.14E-08 -9.81E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 60 6.05E-09 6.24E-09 2.31E-08 -1.10E-08 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.25. Plot of Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 61 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.25. Raw data for Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 5.46E-09 -3.10E-10 4.47E-09 1.22E-09 2.40E-10 -2.73E-09 1.78E-09 -5.70E-10 -4.83E-09 5.10E-10 1.12E-08 3.05E-09 0 2.99E-09 -1.04E-09 3.17E-09 1.63E-09 -7.00E-10 -2.18E-09 1.58E-09 3.10E-10 -4.46E-09 4.10E-10 1.02E-08 2.89E-09 Dose (krad(Si)) 20 30 50 6.88E-09 5.84E-09 6.26E-09 1.00E-11 1.13E-09 1.64E-09 4.68E-09 5.20E-09 4.95E-09 2.15E-09 1.88E-09 3.00E-09 3.00E-10 4.00E-11 3.50E-10 -2.52E-09 -3.40E-09 -2.93E-09 9.50E-10 1.42E-09 9.00E-10 -1.14E-09 -1.37E-09 -1.57E-09 -5.07E-09 -5.45E-09 -5.04E-09 1.09E-09 9.90E-10 6.20E-10 8.90E-09 8.94E-09 8.86E-09 2.95E-09 2.96E-09 2.88E-09 1.21E-09 2.22E-09 2.80E-09 2.82E-09 3.24E-09 1.99E-09 2.59E-09 2.94E-09 2.56E-09 2.40E-09 6.68E-09 9.32E-09 1.09E-08 9.84E-09 9.82E-09 -4.26E-09 -4.89E-09 -5.26E-09 -4.21E-09 -3.34E-09 -8.68E-10 2.43E-09 5.80E-09 -7.53E-09 -7.00E-08 PASS 7.00E-08 PASS -1.17E-09 2.63E-09 6.05E-09 -8.39E-09 -1.00E-07 PASS 1.00E-07 PASS -1.34E-09 2.57E-09 5.72E-09 -8.39E-09 -1.00E-07 PASS 1.00E-07 PASS -1.56E-09 2.91E-09 6.42E-09 -9.55E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 62 -1.60E-09 2.49E-09 5.22E-09 -8.43E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.26. Plot of Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 63 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.26. Raw data for Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 -3.31E-09 5.40E-10 6.19E-09 -7.33E-09 -8.85E-09 1.30E-09 -2.56E-09 -3.05E-08 0.00E+00 3.30E-09 -4.97E-09 1.41E-09 0 -4.78E-09 2.90E-10 6.08E-09 -6.41E-09 -8.13E-09 8.20E-10 -2.54E-09 -3.00E-08 -7.00E-11 3.48E-09 -4.83E-09 1.42E-09 Dose (krad(Si)) 20 30 -1.11E-09 -1.23E-09 1.00E-10 -3.90E-10 6.83E-09 6.90E-09 -6.45E-09 -6.67E-09 -8.94E-09 -1.02E-08 2.15E-09 1.64E-09 -2.45E-09 -3.65E-09 -3.13E-08 -3.05E-08 2.00E-11 -2.00E-11 3.47E-09 4.37E-09 -4.83E-09 -4.83E-09 1.43E-09 1.44E-09 50 -6.00E-11 -1.90E-10 7.04E-09 -8.09E-09 -1.04E-08 2.02E-09 -3.47E-09 -2.94E-08 2.80E-10 3.71E-09 -4.87E-09 1.50E-09 -2.59E-09 -2.55E-09 -1.91E-09 -2.31E-09 -2.34E-09 5.78E-09 6.10E-09 6.15E-09 6.52E-09 6.99E-09 1.33E-08 1.42E-08 1.49E-08 1.56E-08 1.68E-08 -1.84E-08 -1.93E-08 -1.88E-08 -2.02E-08 -2.15E-08 -5.67E-09 1.38E-08 3.21E-08 -4.35E-08 -7.00E-08 PASS 7.00E-08 PASS -5.70E-09 1.40E-08 3.28E-08 -4.42E-08 -1.00E-07 PASS 1.00E-07 PASS -5.63E-09 1.45E-08 3.43E-08 -4.55E-08 -1.00E-07 PASS 1.00E-07 PASS -5.64E-09 1.42E-08 3.33E-08 -4.46E-08 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 64 -5.38E-09 1.37E-08 3.22E-08 -4.30E-08 -1.00E-07 PASS 1.00E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.27. Plot of +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 65 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.27. Raw data for +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS2 1 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VCM=15V Device 0 10 20 30 50 284 3.40E-07 3.59E-07 3.80E-07 4.02E-07 4.29E-07 303 3.36E-07 3.51E-07 3.62E-07 3.77E-07 3.96E-07 314 3.38E-07 3.60E-07 3.74E-07 3.88E-07 4.08E-07 331 3.40E-07 3.77E-07 3.74E-07 3.86E-07 4.08E-07 368 3.26E-07 3.44E-07 3.59E-07 3.72E-07 3.95E-07 404 3.44E-07 3.63E-07 3.79E-07 3.94E-07 4.19E-07 445 3.33E-07 3.50E-07 3.65E-07 3.78E-07 4.06E-07 474 3.36E-07 3.50E-07 3.64E-07 3.78E-07 4.05E-07 500 3.57E-07 3.78E-07 3.93E-07 4.08E-07 4.38E-07 518 3.40E-07 3.55E-07 3.71E-07 3.86E-07 4.09E-07 524 3.44E-07 3.44E-07 3.46E-07 3.44E-07 3.44E-07 558 3.43E-07 3.43E-07 3.45E-07 3.42E-07 3.44E-07 Biased Statistics Average Biased 3.36E-07 3.58E-07 3.70E-07 3.85E-07 4.07E-07 Std Dev Biased 5.59E-09 1.24E-08 8.98E-09 1.15E-08 1.38E-08 Ps90%/90% (+KTL) Biased 3.51E-07 3.92E-07 3.94E-07 4.17E-07 4.45E-07 Ps90%/90% (-KTL) Biased 3.21E-07 3.24E-07 3.45E-07 3.53E-07 3.70E-07 Un-Biased Statistics Average Un-Biased 3.42E-07 3.59E-07 3.75E-07 3.89E-07 4.15E-07 Std Dev Un-Biased 9.41E-09 1.20E-08 1.21E-08 1.24E-08 1.39E-08 Ps90%/90% (+KTL) Un-Biased 3.68E-07 3.92E-07 4.08E-07 4.23E-07 4.53E-07 Ps90%/90% (-KTL) Un-Biased 3.17E-07 3.26E-07 3.41E-07 3.55E-07 3.77E-07 Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 66 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.28. Plot of +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 67 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.28. Raw data for +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS2 2 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VCM=15V Device 0 10 20 30 50 284 3.42E-07 3.67E-07 3.88E-07 4.08E-07 4.40E-07 303 3.40E-07 3.63E-07 3.73E-07 3.89E-07 4.08E-07 314 3.49E-07 3.71E-07 3.82E-07 3.98E-07 4.15E-07 331 3.39E-07 3.71E-07 3.66E-07 3.79E-07 4.01E-07 368 3.38E-07 3.54E-07 3.68E-07 3.78E-07 3.97E-07 404 3.47E-07 3.67E-07 3.83E-07 3.97E-07 4.20E-07 445 3.46E-07 3.69E-07 3.85E-07 3.99E-07 4.25E-07 474 3.42E-07 3.61E-07 3.75E-07 3.90E-07 4.15E-07 500 3.43E-07 3.63E-07 3.81E-07 3.98E-07 4.26E-07 518 3.40E-07 3.56E-07 3.74E-07 3.86E-07 4.11E-07 524 3.50E-07 3.51E-07 3.51E-07 3.50E-07 3.49E-07 558 3.39E-07 3.40E-07 3.41E-07 3.40E-07 3.39E-07 Biased Statistics Average Biased 3.42E-07 3.65E-07 3.76E-07 3.91E-07 4.12E-07 Std Dev Biased 4.27E-09 7.14E-09 9.28E-09 1.26E-08 1.70E-08 Ps90%/90% (+KTL) Biased 3.53E-07 3.85E-07 4.01E-07 4.25E-07 4.59E-07 Ps90%/90% (-KTL) Biased 3.30E-07 3.45E-07 3.50E-07 3.56E-07 3.66E-07 Un-Biased Statistics Average Un-Biased 3.44E-07 3.63E-07 3.80E-07 3.94E-07 4.19E-07 Std Dev Un-Biased 2.80E-09 5.10E-09 4.80E-09 5.42E-09 6.72E-09 Ps90%/90% (+KTL) Un-Biased 3.51E-07 3.77E-07 3.93E-07 4.09E-07 4.38E-07 Ps90%/90% (-KTL) Un-Biased 3.36E-07 3.49E-07 3.66E-07 3.79E-07 4.01E-07 Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 68 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.29. Plot of +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 69 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.29. Raw data for +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS2 3 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VCM=15V Device 0 10 20 30 50 284 3.44E-07 3.70E-07 3.90E-07 4.07E-07 4.37E-07 303 3.44E-07 3.64E-07 3.74E-07 3.91E-07 4.11E-07 314 3.43E-07 3.65E-07 3.75E-07 3.92E-07 4.10E-07 331 3.38E-07 3.69E-07 3.65E-07 3.77E-07 3.98E-07 368 3.39E-07 3.55E-07 3.68E-07 3.78E-07 3.99E-07 404 3.50E-07 3.70E-07 3.84E-07 3.98E-07 4.22E-07 445 3.32E-07 3.49E-07 3.64E-07 3.79E-07 4.06E-07 474 3.38E-07 3.57E-07 3.72E-07 3.86E-07 4.12E-07 500 3.41E-07 3.61E-07 3.78E-07 3.92E-07 4.21E-07 518 3.38E-07 3.53E-07 3.69E-07 3.82E-07 4.05E-07 524 3.48E-07 3.49E-07 3.47E-07 3.45E-07 3.46E-07 558 3.45E-07 3.46E-07 3.46E-07 3.46E-07 3.44E-07 Biased Statistics Average Biased 3.42E-07 3.64E-07 3.75E-07 3.89E-07 4.11E-07 Std Dev Biased 2.71E-09 5.98E-09 9.61E-09 1.25E-08 1.58E-08 Ps90%/90% (+KTL) Biased 3.49E-07 3.81E-07 4.01E-07 4.23E-07 4.55E-07 Ps90%/90% (-KTL) Biased 3.34E-07 3.48E-07 3.48E-07 3.55E-07 3.68E-07 Un-Biased Statistics Average Un-Biased 3.40E-07 3.58E-07 3.73E-07 3.87E-07 4.13E-07 Std Dev Un-Biased 6.63E-09 8.11E-09 8.06E-09 7.68E-09 8.12E-09 Ps90%/90% (+KTL) Un-Biased 3.58E-07 3.80E-07 3.95E-07 4.09E-07 4.35E-07 Ps90%/90% (-KTL) Un-Biased 3.21E-07 3.36E-07 3.51E-07 3.66E-07 3.91E-07 Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 70 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.30. Plot of +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 71 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.30. Raw data for +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS2 4 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VCM=15V Device 0 10 20 30 50 284 3.38E-07 3.59E-07 3.78E-07 3.96E-07 4.26E-07 303 3.38E-07 3.53E-07 3.63E-07 3.77E-07 3.98E-07 314 3.48E-07 3.68E-07 3.81E-07 3.96E-07 4.15E-07 331 3.46E-07 3.80E-07 3.78E-07 3.89E-07 4.12E-07 368 3.25E-07 3.42E-07 3.57E-07 3.69E-07 3.93E-07 404 3.38E-07 3.54E-07 3.69E-07 3.86E-07 4.10E-07 445 3.32E-07 3.50E-07 3.67E-07 3.79E-07 4.06E-07 474 3.36E-07 3.51E-07 3.64E-07 3.79E-07 4.05E-07 500 3.38E-07 3.56E-07 3.71E-07 3.84E-07 4.13E-07 518 3.36E-07 3.57E-07 3.74E-07 3.86E-07 4.11E-07 524 3.48E-07 3.49E-07 3.51E-07 3.48E-07 3.48E-07 558 3.35E-07 3.36E-07 3.35E-07 3.35E-07 3.35E-07 Biased Statistics Average Biased 3.39E-07 3.60E-07 3.71E-07 3.85E-07 4.09E-07 Std Dev Biased 9.01E-09 1.47E-08 1.05E-08 1.20E-08 1.35E-08 Ps90%/90% (+KTL) Biased 3.64E-07 4.01E-07 4.00E-07 4.18E-07 4.46E-07 Ps90%/90% (-KTL) Biased 3.14E-07 3.20E-07 3.43E-07 3.53E-07 3.72E-07 Un-Biased Statistics Average Un-Biased 3.36E-07 3.54E-07 3.69E-07 3.83E-07 4.09E-07 Std Dev Un-Biased 2.19E-09 2.92E-09 3.83E-09 3.47E-09 3.54E-09 Ps90%/90% (+KTL) Un-Biased 3.42E-07 3.62E-07 3.80E-07 3.92E-07 4.19E-07 Ps90%/90% (-KTL) Un-Biased 3.30E-07 3.46E-07 3.59E-07 3.73E-07 3.99E-07 Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 72 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.31. Plot of -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 73 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.31. Raw data for -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS2 1 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VCM=15V Device 0 10 20 30 50 284 3.43E-07 3.65E-07 3.83E-07 4.03E-07 4.34E-07 303 3.39E-07 3.57E-07 3.70E-07 3.84E-07 4.05E-07 314 3.40E-07 3.61E-07 3.72E-07 3.87E-07 4.07E-07 331 3.38E-07 3.73E-07 3.71E-07 3.84E-07 4.05E-07 368 3.33E-07 3.49E-07 3.64E-07 3.77E-07 4.01E-07 404 3.39E-07 3.53E-07 3.68E-07 3.84E-07 4.09E-07 445 3.33E-07 3.49E-07 3.64E-07 3.78E-07 4.01E-07 474 3.40E-07 3.53E-07 3.68E-07 3.82E-07 4.09E-07 500 3.43E-07 3.62E-07 3.77E-07 3.92E-07 4.21E-07 518 3.38E-07 3.52E-07 3.68E-07 3.81E-07 4.05E-07 524 3.42E-07 3.41E-07 3.43E-07 3.41E-07 3.41E-07 558 3.39E-07 3.41E-07 3.40E-07 3.39E-07 3.39E-07 Biased Statistics Average Biased 3.38E-07 3.61E-07 3.72E-07 3.87E-07 4.11E-07 Std Dev Biased 3.49E-09 8.94E-09 7.06E-09 9.67E-09 1.30E-08 Ps90%/90% (+KTL) Biased 3.48E-07 3.86E-07 3.91E-07 4.14E-07 4.46E-07 Ps90%/90% (-KTL) Biased 3.29E-07 3.37E-07 3.53E-07 3.61E-07 3.75E-07 Un-Biased Statistics Average Un-Biased 3.39E-07 3.54E-07 3.69E-07 3.84E-07 4.09E-07 Std Dev Un-Biased 3.88E-09 4.87E-09 5.00E-09 5.19E-09 7.48E-09 Ps90%/90% (+KTL) Un-Biased 3.49E-07 3.67E-07 3.83E-07 3.98E-07 4.30E-07 Ps90%/90% (-KTL) Un-Biased 3.28E-07 3.40E-07 3.55E-07 3.69E-07 3.89E-07 Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 74 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.32. Plot of -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 75 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.32. Raw data for -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS2 2 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VCM=15V Device 0 10 20 30 50 284 3.37E-07 3.60E-07 3.80E-07 4.00E-07 4.30E-07 303 3.38E-07 3.56E-07 3.69E-07 3.84E-07 4.04E-07 314 3.38E-07 3.59E-07 3.72E-07 3.87E-07 4.07E-07 331 3.39E-07 3.68E-07 3.66E-07 3.78E-07 3.98E-07 368 3.33E-07 3.46E-07 3.61E-07 3.70E-07 3.88E-07 404 3.46E-07 3.64E-07 3.81E-07 3.95E-07 4.18E-07 445 3.39E-07 3.54E-07 3.70E-07 3.82E-07 4.09E-07 474 3.39E-07 3.58E-07 3.73E-07 3.87E-07 4.13E-07 500 3.35E-07 3.54E-07 3.71E-07 3.85E-07 4.13E-07 518 3.35E-07 3.49E-07 3.66E-07 3.79E-07 4.03E-07 524 3.40E-07 3.42E-07 3.44E-07 3.42E-07 3.41E-07 558 3.37E-07 3.37E-07 3.38E-07 3.38E-07 3.37E-07 Biased Statistics Average Biased 3.37E-07 3.58E-07 3.70E-07 3.84E-07 4.05E-07 Std Dev Biased 2.41E-09 8.01E-09 7.36E-09 1.12E-08 1.55E-08 Ps90%/90% (+KTL) Biased 3.43E-07 3.80E-07 3.90E-07 4.15E-07 4.48E-07 Ps90%/90% (-KTL) Biased 3.30E-07 3.36E-07 3.49E-07 3.53E-07 3.63E-07 Un-Biased Statistics Average Un-Biased 3.39E-07 3.56E-07 3.72E-07 3.86E-07 4.11E-07 Std Dev Un-Biased 4.39E-09 5.44E-09 5.56E-09 6.21E-09 5.45E-09 Ps90%/90% (+KTL) Un-Biased 3.51E-07 3.71E-07 3.87E-07 4.03E-07 4.26E-07 Ps90%/90% (-KTL) Un-Biased 3.27E-07 3.41E-07 3.57E-07 3.69E-07 3.96E-07 Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 76 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.33. Plot of -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 77 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.33. Raw data for -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS2 3 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VCM=15V Device 0 10 20 30 50 284 3.40E-07 3.61E-07 3.80E-07 4.00E-07 4.30E-07 303 3.43E-07 3.62E-07 3.74E-07 3.89E-07 4.08E-07 314 3.39E-07 3.58E-07 3.71E-07 3.85E-07 4.05E-07 331 3.37E-07 3.65E-07 3.62E-07 3.74E-07 3.95E-07 368 3.40E-07 3.52E-07 3.66E-07 3.77E-07 3.96E-07 404 3.51E-07 3.71E-07 3.86E-07 4.01E-07 4.24E-07 445 3.30E-07 3.46E-07 3.61E-07 3.76E-07 4.03E-07 474 3.37E-07 3.56E-07 3.70E-07 3.86E-07 4.12E-07 500 3.43E-07 3.65E-07 3.82E-07 3.97E-07 4.27E-07 518 3.38E-07 3.51E-07 3.67E-07 3.81E-07 4.04E-07 524 3.36E-07 3.37E-07 3.37E-07 3.37E-07 3.36E-07 558 3.41E-07 3.42E-07 3.43E-07 3.41E-07 3.41E-07 Biased Statistics Average Biased 3.40E-07 3.60E-07 3.70E-07 3.85E-07 4.07E-07 Std Dev Biased 2.40E-09 4.67E-09 6.93E-09 1.03E-08 1.40E-08 Ps90%/90% (+KTL) Biased 3.46E-07 3.72E-07 3.89E-07 4.13E-07 4.45E-07 Ps90%/90% (-KTL) Biased 3.33E-07 3.47E-07 3.51E-07 3.57E-07 3.68E-07 Un-Biased Statistics Average Un-Biased 3.40E-07 3.58E-07 3.73E-07 3.88E-07 4.14E-07 Std Dev Un-Biased 7.89E-09 9.98E-09 1.05E-08 1.07E-08 1.10E-08 Ps90%/90% (+KTL) Un-Biased 3.61E-07 3.85E-07 4.02E-07 4.18E-07 4.44E-07 Ps90%/90% (-KTL) Un-Biased 3.18E-07 3.30E-07 3.45E-07 3.59E-07 3.84E-07 Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 78 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.34. Plot of -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 79 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.34. Raw data for -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS2 4 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VCM=15V Device 0 10 20 30 50 284 3.36E-07 3.58E-07 3.75E-07 3.95E-07 4.22E-07 303 3.37E-07 3.49E-07 3.60E-07 3.75E-07 3.94E-07 314 3.39E-07 3.60E-07 3.71E-07 3.85E-07 4.05E-07 331 3.49E-07 3.82E-07 3.81E-07 3.93E-07 4.16E-07 368 3.33E-07 3.47E-07 3.62E-07 3.75E-07 4.01E-07 404 3.37E-07 3.49E-07 3.65E-07 3.80E-07 4.06E-07 445 3.35E-07 3.50E-07 3.65E-07 3.81E-07 4.06E-07 474 3.58E-07 3.77E-07 3.91E-07 4.04E-07 4.29E-07 500 3.35E-07 3.53E-07 3.68E-07 3.84E-07 4.11E-07 518 3.38E-07 3.52E-07 3.68E-07 3.80E-07 4.04E-07 524 3.51E-07 3.52E-07 3.53E-07 3.52E-07 3.51E-07 558 3.33E-07 3.34E-07 3.33E-07 3.33E-07 3.33E-07 Biased Statistics Average Biased 3.39E-07 3.59E-07 3.70E-07 3.85E-07 4.08E-07 Std Dev Biased 6.26E-09 1.41E-08 8.98E-09 9.60E-09 1.13E-08 Ps90%/90% (+KTL) Biased 3.56E-07 3.98E-07 3.94E-07 4.11E-07 4.39E-07 Ps90%/90% (-KTL) Biased 3.22E-07 3.20E-07 3.45E-07 3.58E-07 3.77E-07 Un-Biased Statistics Average Un-Biased 3.40E-07 3.56E-07 3.71E-07 3.86E-07 4.11E-07 Std Dev Un-Biased 9.62E-09 1.18E-08 1.13E-08 1.05E-08 1.02E-08 Ps90%/90% (+KTL) Un-Biased 3.67E-07 3.89E-07 4.02E-07 4.14E-07 4.39E-07 Ps90%/90% (-KTL) Un-Biased 3.14E-07 3.24E-07 3.40E-07 3.57E-07 3.83E-07 Specification MIN -7.15E-07 -7.65E-07 -8.15E-07 -8.15E-07 -8.65E-07 Status PASS PASS PASS PASS PASS Specification MAX 7.15E-07 7.65E-07 8.15E-07 8.15E-07 8.65E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 80 Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.35. Plot of Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 81 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.35. Raw data for Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 -3.95E-04 -1.11E-05 -1.19E-04 -9.24E-06 8.61E-05 4.09E-05 -7.85E-05 -2.72E-04 -2.71E-04 -2.53E-04 4.74E-05 -2.48E-04 0 -3.62E-04 1.26E-06 -1.02E-04 1.06E-05 1.09E-04 5.19E-05 -6.95E-05 -2.64E-04 -2.55E-04 -2.42E-04 4.99E-05 -2.47E-04 Dose (krad(Si)) 20 30 -3.85E-04 -3.81E-04 -8.27E-06 -3.81E-06 -1.14E-04 -1.13E-04 -5.62E-06 -6.00E-08 8.89E-05 8.55E-05 3.75E-05 3.46E-05 -8.42E-05 -8.74E-05 -2.78E-04 -2.81E-04 -2.76E-04 -2.80E-04 -2.56E-04 -2.61E-04 5.00E-05 4.96E-05 -2.43E-04 -2.45E-04 50 -3.74E-04 -4.65E-06 -1.16E-04 -2.84E-06 8.29E-05 2.61E-05 -8.87E-05 -2.87E-04 -2.87E-04 -2.66E-04 5.06E-05 -2.45E-04 -6.86E-05 -8.95E-05 -8.48E-05 -8.25E-05 -8.30E-05 1.80E-04 1.85E-04 1.83E-04 1.81E-04 1.77E-04 4.25E-04 4.19E-04 4.16E-04 4.14E-04 4.03E-04 -5.62E-04 -5.98E-04 -5.85E-04 -5.79E-04 -5.70E-04 -1.56E-04 1.41E-04 2.31E-04 -5.42E-04 -8.00E-04 PASS 8.00E-04 PASS -1.67E-04 1.42E-04 2.21E-04 -5.55E-04 -9.50E-04 PASS 9.50E-04 PASS -1.71E-04 1.42E-04 2.18E-04 -5.61E-04 -9.50E-04 PASS 9.50E-04 PASS -1.75E-04 1.42E-04 2.16E-04 -5.66E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 82 -1.80E-04 1.42E-04 2.10E-04 -5.71E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.36. Plot of Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 83 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.36. Raw data for Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 -6.18E-05 5.41E-05 -5.05E-05 -3.56E-06 4.62E-05 -2.54E-04 7.74E-05 -2.41E-04 -8.96E-05 -2.54E-04 -1.31E-04 -2.48E-04 0 -4.12E-05 6.44E-05 -3.52E-05 9.59E-06 7.32E-05 -2.39E-04 9.42E-05 -2.31E-04 -7.73E-05 -2.44E-04 -1.29E-04 -2.47E-04 Dose (krad(Si)) 20 30 -5.89E-05 -5.25E-05 5.98E-05 6.39E-05 -4.47E-05 -4.39E-05 -7.00E-08 3.20E-06 5.21E-05 5.32E-05 -2.61E-04 -2.63E-04 7.38E-05 7.01E-05 -2.45E-04 -2.48E-04 -9.25E-05 -9.57E-05 -2.56E-04 -2.61E-04 -1.29E-04 -1.30E-04 -2.47E-04 -2.48E-04 50 -4.91E-05 6.60E-05 -4.06E-05 9.23E-06 5.25E-05 -2.67E-04 6.71E-05 -2.53E-04 -9.92E-05 -2.65E-04 -1.29E-04 -2.48E-04 1.42E-05 -3.11E-06 1.65E-06 4.79E-06 7.59E-06 5.37E-05 5.34E-05 5.42E-05 5.36E-05 5.23E-05 1.61E-04 1.43E-04 1.50E-04 1.52E-04 1.51E-04 -1.33E-04 -1.49E-04 -1.47E-04 -1.42E-04 -1.36E-04 -1.40E-04 1.48E-04 2.67E-04 -5.46E-04 -8.00E-04 PASS 8.00E-04 PASS -1.52E-04 1.46E-04 2.48E-04 -5.53E-04 -9.50E-04 PASS 9.50E-04 PASS -1.56E-04 1.46E-04 2.45E-04 -5.57E-04 -9.50E-04 PASS 9.50E-04 PASS -1.60E-04 1.46E-04 2.42E-04 -5.61E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 84 -1.64E-04 1.47E-04 2.40E-04 -5.67E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.37. Plot of Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 85 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.37. Raw data for Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 6.08E-05 -1.78E-05 4.93E-05 -2.66E-05 1.97E-04 -1.60E-04 1.36E-05 -2.51E-04 5.78E-05 -1.38E-05 -8.27E-06 4.07E-05 0 8.80E-05 2.23E-06 7.02E-05 -3.81E-06 2.26E-04 -1.45E-04 2.70E-05 -2.38E-04 6.82E-05 -3.20E-06 -5.50E-06 4.46E-05 Dose (krad(Si)) 20 30 5.79E-05 6.92E-05 -1.81E-05 -1.53E-05 5.20E-05 5.28E-05 -1.96E-05 -1.69E-05 2.03E-04 2.04E-04 -1.66E-04 -1.64E-04 6.45E-06 5.49E-06 -2.57E-04 -2.58E-04 5.33E-05 5.33E-05 -1.49E-05 -1.33E-05 -5.38E-06 -4.77E-06 4.33E-05 4.36E-05 50 7.77E-05 -1.58E-05 5.21E-05 -1.48E-05 2.04E-04 -1.67E-04 3.00E-07 -2.62E-04 4.84E-05 -1.99E-05 -4.53E-06 4.46E-05 7.66E-05 5.26E-05 5.49E-05 5.88E-05 6.07E-05 9.30E-05 8.99E-05 9.04E-05 9.00E-05 9.01E-05 3.32E-04 2.99E-04 3.03E-04 3.06E-04 3.08E-04 -1.78E-04 -1.94E-04 -1.93E-04 -1.88E-04 -1.86E-04 -5.83E-05 1.29E-04 2.94E-04 -4.11E-04 -8.00E-04 PASS 8.00E-04 PASS -7.07E-05 1.30E-04 2.85E-04 -4.26E-04 -9.50E-04 PASS 9.50E-04 PASS -7.56E-05 1.31E-04 2.82E-04 -4.34E-04 -9.50E-04 PASS 9.50E-04 PASS -7.52E-05 1.30E-04 2.82E-04 -4.33E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 86 -8.02E-05 1.30E-04 2.76E-04 -4.36E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.38. Plot of Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 87 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.38. Raw data for Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 2.20E-04 -2.75E-04 -1.77E-04 2.07E-04 6.09E-05 -3.86E-05 -1.10E-04 -3.85E-04 -1.82E-04 1.04E-04 1.32E-04 1.96E-05 0 2.41E-04 -2.60E-04 -1.60E-04 2.31E-04 7.73E-05 -2.78E-05 -9.57E-05 -3.74E-04 -1.66E-04 1.16E-04 1.37E-04 2.20E-05 Dose (krad(Si)) 20 30 2.25E-04 2.32E-04 -2.73E-04 -2.68E-04 -1.73E-04 -1.75E-04 2.11E-04 2.11E-04 6.48E-05 6.95E-05 -4.11E-05 -4.33E-05 -1.14E-04 -1.17E-04 -3.90E-04 -3.93E-04 -1.85E-04 -1.88E-04 1.01E-04 9.88E-05 1.37E-04 1.35E-04 2.30E-05 2.17E-05 50 2.37E-04 -2.67E-04 -1.75E-04 2.11E-04 6.98E-05 -4.80E-05 -1.21E-04 -3.96E-04 -1.90E-04 9.10E-05 1.37E-04 2.34E-05 2.59E-05 7.08E-06 1.11E-05 1.38E-05 1.53E-05 2.28E-04 2.25E-04 2.25E-04 2.26E-04 2.27E-04 6.50E-04 6.23E-04 6.29E-04 6.34E-04 6.38E-04 -5.98E-04 -6.09E-04 -6.07E-04 -6.07E-04 -6.08E-04 -1.10E-04 1.81E-04 3.86E-04 -6.05E-04 -8.00E-04 PASS 8.00E-04 PASS -1.23E-04 1.81E-04 3.73E-04 -6.19E-04 -9.50E-04 PASS 9.50E-04 PASS -1.26E-04 1.82E-04 3.72E-04 -6.24E-04 -9.50E-04 PASS 9.50E-04 PASS -1.28E-04 1.82E-04 3.71E-04 -6.27E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 88 -1.33E-04 1.80E-04 3.62E-04 -6.27E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.39. Plot of Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 89 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.39. Raw data for Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 -3.62E-09 -1.70E-09 -2.34E-09 -3.74E-09 -1.80E-09 -6.30E-10 -2.60E-09 1.19E-09 -1.51E-09 -1.54E-09 6.50E-10 -1.25E-09 0 -3.27E-09 -1.76E-09 -2.23E-09 -4.25E-09 -1.49E-09 -8.80E-10 -2.72E-09 1.30E-09 -1.39E-09 -1.23E-09 6.60E-10 -1.27E-09 Dose (krad(Si)) 20 30 -3.57E-09 -4.63E-09 -8.80E-10 -7.60E-10 -2.43E-09 -2.94E-09 -3.78E-09 -3.89E-09 -2.04E-09 -2.22E-09 -5.60E-10 -4.20E-10 -2.39E-09 -2.44E-09 1.74E-09 1.93E-09 -1.49E-09 -2.11E-09 -2.03E-09 -2.57E-09 6.20E-10 6.90E-10 -1.24E-09 -1.18E-09 50 -4.25E-09 -1.08E-09 -2.88E-09 -4.18E-09 -2.28E-09 -4.30E-10 -2.98E-09 1.48E-09 -1.84E-09 -1.78E-09 6.60E-10 -1.12E-09 -2.60E-09 -2.64E-09 -2.54E-09 -2.89E-09 -2.93E-09 1.15E-09 9.81E-10 1.18E-09 1.50E-09 1.34E-09 5.40E-10 5.00E-11 7.09E-10 1.23E-09 7.33E-10 -5.74E-09 -5.33E-09 -5.79E-09 -7.00E-09 -6.60E-09 -9.84E-10 1.45E-09 3.01E-09 -4.97E-09 -7.00E-08 PASS 7.00E-08 PASS -1.02E-09 1.42E-09 2.87E-09 -4.91E-09 -1.00E-07 PASS 1.00E-07 PASS -9.46E-10 1.65E-09 3.58E-09 -5.48E-09 -1.00E-07 PASS 1.00E-07 PASS -1.12E-09 1.91E-09 4.12E-09 -6.36E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 90 -1.11E-09 1.71E-09 3.57E-09 -5.79E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.40. Plot of Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 91 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.40. Raw data for Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 1.19E-09 1.06E-09 1.21E-09 7.10E-10 2.74E-09 3.06E-09 3.05E-09 3.08E-09 2.00E-11 1.30E-10 -8.00E-11 1.90E-10 -8.40E-10 3.20E-10 2.80E-10 2.30E-10 -1.03E-09 -1.69E-09 -1.27E-09 -9.60E-10 8.80E-10 1.04E-09 1.71E-09 1.67E-09 4.61E-09 4.87E-09 4.81E-09 5.48E-09 -2.29E-09 -2.37E-09 -2.45E-09 -2.90E-09 2.67E-09 2.47E-09 2.39E-09 1.72E-09 -2.51E-09 -2.55E-09 -2.55E-09 -2.54E-09 5.34E-09 5.45E-09 5.44E-09 5.42E-09 1.63E-09 1.68E-09 1.63E-09 1.68E-09 50 1.19E-09 3.41E-09 5.50E-10 -5.00E-11 -6.70E-10 2.30E-09 4.94E-09 -2.93E-09 1.89E-09 -3.03E-09 5.38E-09 1.67E-09 4.16E-10 5.76E-10 6.38E-10 6.50E-10 8.86E-10 1.57E-09 1.72E-09 1.61E-09 1.49E-09 1.57E-09 4.71E-09 5.29E-09 5.07E-09 4.74E-09 5.19E-09 -3.88E-09 -4.13E-09 -3.79E-09 -3.44E-09 -3.42E-09 6.72E-10 3.10E-09 9.17E-09 -7.83E-09 -7.00E-08 PASS 7.00E-08 PASS 6.92E-10 3.19E-09 9.43E-09 -8.05E-09 -1.00E-07 PASS 1.00E-07 PASS 7.82E-10 3.21E-09 9.58E-09 -8.02E-09 -1.00E-07 PASS 1.00E-07 PASS 6.86E-10 3.47E-09 1.02E-08 -8.84E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 92 6.34E-10 3.50E-09 1.02E-08 -8.97E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.41. Plot of Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 93 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.41. Raw data for Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 2.12E-09 1.57E-09 1.99E-09 1.94E-09 2.75E-09 -2.67E-09 -2.69E-09 -2.66E-09 -2.59E-09 -2.26E-09 6.30E-10 5.70E-10 5.80E-10 8.50E-10 1.00E-10 3.77E-09 3.99E-09 4.00E-09 4.31E-09 3.76E-09 5.20E-09 4.59E-09 5.33E-09 5.00E-09 5.29E-09 2.47E-09 2.44E-09 2.27E-09 2.78E-09 2.11E-09 -1.44E-09 -1.76E-09 -1.30E-09 -1.39E-09 -1.45E-09 -3.84E-09 -3.83E-09 -4.05E-09 -3.90E-09 -4.18E-09 2.08E-09 2.34E-09 1.88E-09 2.10E-09 1.39E-09 4.94E-09 4.74E-09 4.81E-09 5.56E-09 5.20E-09 8.50E-10 9.10E-10 8.50E-10 8.90E-10 8.90E-10 3.16E-09 3.23E-09 3.18E-09 3.20E-09 3.14E-09 1.81E-09 1.61E-09 1.85E-09 1.90E-09 1.93E-09 3.04E-09 2.92E-09 3.11E-09 3.03E-09 3.01E-09 1.01E-08 9.61E-09 1.04E-08 1.02E-08 1.02E-08 -6.52E-09 -6.40E-09 -6.68E-09 -6.40E-09 -6.32E-09 8.42E-10 3.47E-09 1.04E-08 -8.67E-09 -7.00E-08 PASS 7.00E-08 PASS 7.86E-10 3.48E-09 1.03E-08 -8.77E-09 -1.00E-07 PASS 1.00E-07 PASS 7.22E-10 3.44E-09 1.02E-08 -8.71E-09 -1.00E-07 PASS 1.00E-07 PASS 1.03E-09 3.70E-09 1.12E-08 -9.13E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 94 6.14E-10 3.57E-09 1.04E-08 -9.19E-09 -1.00E-07 PASS 1.00E-07 PASS Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-07 1.00E-07 5.00E-08 0.00E+00 -5.00E-08 -1.00E-07 -1.50E-07 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.42. Plot of Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 95 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.42. Raw data for Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total 10 4.40E-09 3.32E-09 1.46E-09 2.17E-09 7.65E-09 1.22E-09 -4.01E-09 -6.50E-10 -2.84E-09 7.00E-11 -7.10E-10 4.05E-09 0 4.27E-09 3.53E-09 1.27E-09 2.45E-09 7.68E-09 1.27E-09 -3.92E-09 -2.20E-10 -3.00E-09 -1.40E-10 -7.00E-10 4.00E-09 Dose (krad(Si)) 20 30 50 4.72E-09 4.39E-09 5.49E-09 3.44E-09 3.65E-09 3.97E-09 2.14E-09 1.91E-09 2.35E-09 2.17E-09 2.38E-09 2.33E-09 7.30E-09 7.12E-09 7.64E-09 1.92E-09 2.03E-09 2.31E-09 -3.21E-09 -2.99E-09 -2.80E-09 -1.30E-10 -2.80E-10 8.40E-10 -3.00E-09 -3.35E-09 -3.18E-09 4.00E-11 5.70E-10 9.00E-10 -6.60E-10 -6.70E-10 -6.50E-10 4.01E-09 4.03E-09 4.07E-09 3.84E-09 3.80E-09 3.95E-09 3.89E-09 4.36E-09 2.43E-09 2.43E-09 2.15E-09 2.06E-09 2.26E-09 1.05E-08 1.05E-08 9.85E-09 9.53E-09 1.05E-08 -2.82E-09 -2.85E-09 -1.95E-09 -1.75E-09 -1.83E-09 -1.20E-09 2.17E-09 4.75E-09 -7.15E-09 -7.00E-08 PASS 7.00E-08 PASS -1.24E-09 2.14E-09 4.63E-09 -7.11E-09 -1.00E-07 PASS 1.00E-07 PASS -8.76E-10 2.19E-09 5.13E-09 -6.88E-09 -1.00E-07 PASS 1.00E-07 PASS -8.04E-10 2.32E-09 5.55E-09 -7.15E-09 -1.00E-07 PASS 1.00E-07 PASS An ISO 9001:2008 and DSCC Certified Company 96 -3.86E-10 2.45E-09 6.34E-09 -7.11E-09 -1.00E-07 PASS 1.00E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.43. Plot of +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 97 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.43. Raw data for +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.53E-07 -3.67E-07 -3.61E-07 -3.85E-07 -3.47E-07 -3.58E-07 -3.27E-07 -3.72E-07 -3.83E-07 -3.61E-07 -3.71E-07 -3.37E-07 Total 10 -3.56E-07 -3.73E-07 -3.66E-07 -3.97E-07 -3.56E-07 -3.66E-07 -3.35E-07 -3.78E-07 -3.90E-07 -3.67E-07 -3.74E-07 -3.39E-07 Dose (krad(Si)) 20 30 -3.65E-07 -3.70E-07 -3.78E-07 -3.80E-07 -3.73E-07 -3.75E-07 -3.95E-07 -4.00E-07 -3.60E-07 -3.65E-07 -3.70E-07 -3.75E-07 -3.40E-07 -3.49E-07 -3.86E-07 -3.88E-07 -3.97E-07 -4.01E-07 -3.73E-07 -3.78E-07 -3.70E-07 -3.72E-07 -3.37E-07 -3.38E-07 50 -3.76E-07 -3.89E-07 -3.86E-07 -4.09E-07 -3.73E-07 -3.84E-07 -3.59E-07 -3.97E-07 -4.10E-07 -3.87E-07 -3.70E-07 -3.37E-07 -3.63E-07 -3.69E-07 -3.74E-07 -3.78E-07 -3.87E-07 1.44E-08 1.68E-08 1.38E-08 1.36E-08 1.43E-08 -3.23E-07 -3.23E-07 -3.37E-07 -3.41E-07 -3.47E-07 -4.02E-07 -4.15E-07 -4.12E-07 -4.15E-07 -4.26E-07 -3.60E-07 2.10E-08 -3.02E-07 -4.18E-07 -7.15E-07 PASS 7.15E-07 PASS -3.67E-07 2.06E-08 -3.11E-07 -4.23E-07 -7.65E-07 PASS 7.65E-07 PASS -3.74E-07 2.14E-08 -3.15E-07 -4.32E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 98 -3.78E-07 1.90E-08 -3.26E-07 -4.30E-07 -8.15E-07 PASS 8.15E-07 PASS -3.87E-07 1.88E-08 -3.36E-07 -4.39E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.44. Plot of +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 99 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.44. Raw data for +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.54E-07 -3.65E-07 -3.66E-07 -3.73E-07 -3.34E-07 -3.39E-07 -3.28E-07 -3.71E-07 -3.72E-07 -3.58E-07 -3.54E-07 -3.50E-07 Total 10 -3.57E-07 -3.70E-07 -3.72E-07 -3.84E-07 -3.46E-07 -3.50E-07 -3.35E-07 -3.78E-07 -3.79E-07 -3.65E-07 -3.56E-07 -3.51E-07 Dose (krad(Si)) 20 30 -3.66E-07 -3.72E-07 -3.77E-07 -3.79E-07 -3.79E-07 -3.81E-07 -3.83E-07 -3.88E-07 -3.51E-07 -3.55E-07 -3.56E-07 -3.61E-07 -3.46E-07 -3.51E-07 -3.87E-07 -3.90E-07 -3.87E-07 -3.92E-07 -3.71E-07 -3.75E-07 -3.53E-07 -3.54E-07 -3.48E-07 -3.50E-07 50 -3.79E-07 -3.87E-07 -3.93E-07 -3.96E-07 -3.63E-07 -3.68E-07 -3.59E-07 -3.99E-07 -4.02E-07 -3.84E-07 -3.54E-07 -3.49E-07 -3.59E-07 -3.66E-07 -3.71E-07 -3.75E-07 -3.84E-07 1.51E-08 1.47E-08 1.31E-08 1.25E-08 1.30E-08 -3.17E-07 -3.25E-07 -3.35E-07 -3.41E-07 -3.48E-07 -4.00E-07 -4.06E-07 -4.07E-07 -4.09E-07 -4.19E-07 -3.54E-07 1.98E-08 -3.00E-07 -4.08E-07 -7.15E-07 PASS 7.15E-07 PASS -3.62E-07 1.89E-08 -3.10E-07 -4.13E-07 -7.65E-07 PASS 7.65E-07 PASS -3.69E-07 1.86E-08 -3.19E-07 -4.20E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 100 -3.74E-07 1.77E-08 -3.25E-07 -4.22E-07 -8.15E-07 PASS 8.15E-07 PASS -3.82E-07 1.88E-08 -3.31E-07 -4.34E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.45. Plot of +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 101 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.45. Raw data for +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.54E-07 -3.69E-07 -3.63E-07 -3.74E-07 -3.32E-07 -3.33E-07 -3.32E-07 -3.78E-07 -3.69E-07 -3.56E-07 -3.60E-07 -3.49E-07 Total 10 -3.56E-07 -3.75E-07 -3.69E-07 -3.84E-07 -3.46E-07 -3.41E-07 -3.40E-07 -3.84E-07 -3.75E-07 -3.63E-07 -3.62E-07 -3.51E-07 Dose (krad(Si)) 20 30 -3.67E-07 -3.72E-07 -3.81E-07 -3.83E-07 -3.74E-07 -3.77E-07 -3.83E-07 -3.88E-07 -3.50E-07 -3.55E-07 -3.50E-07 -3.56E-07 -3.51E-07 -3.55E-07 -3.93E-07 -3.96E-07 -3.84E-07 -3.87E-07 -3.69E-07 -3.73E-07 -3.57E-07 -3.59E-07 -3.48E-07 -3.49E-07 50 -3.81E-07 -3.93E-07 -3.86E-07 -3.98E-07 -3.64E-07 -3.66E-07 -3.64E-07 -4.05E-07 -3.97E-07 -3.81E-07 -3.58E-07 -3.48E-07 -3.59E-07 -3.66E-07 -3.71E-07 -3.75E-07 -3.84E-07 1.64E-08 1.54E-08 1.35E-08 1.26E-08 1.31E-08 -3.14E-07 -3.24E-07 -3.34E-07 -3.40E-07 -3.48E-07 -4.04E-07 -4.08E-07 -4.08E-07 -4.10E-07 -4.20E-07 -3.54E-07 2.09E-08 -2.96E-07 -4.11E-07 -7.15E-07 PASS 7.15E-07 PASS -3.61E-07 2.01E-08 -3.06E-07 -4.16E-07 -7.65E-07 PASS 7.65E-07 PASS -3.69E-07 1.93E-08 -3.16E-07 -4.22E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 102 -3.73E-07 1.84E-08 -3.23E-07 -4.24E-07 -8.15E-07 PASS 8.15E-07 PASS -3.83E-07 1.84E-08 -3.32E-07 -4.33E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.46. Plot of +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 103 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.46. Raw data for +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.39E-07 -3.65E-07 -3.60E-07 -3.84E-07 -3.49E-07 -3.56E-07 -3.30E-07 -3.73E-07 -3.77E-07 -3.60E-07 -3.72E-07 -3.27E-07 Total 10 -3.47E-07 -3.72E-07 -3.65E-07 -3.94E-07 -3.59E-07 -3.64E-07 -3.38E-07 -3.81E-07 -3.83E-07 -3.67E-07 -3.73E-07 -3.28E-07 Dose (krad(Si)) 20 30 -3.55E-07 -3.60E-07 -3.78E-07 -3.80E-07 -3.70E-07 -3.74E-07 -3.93E-07 -3.98E-07 -3.64E-07 -3.70E-07 -3.71E-07 -3.75E-07 -3.48E-07 -3.52E-07 -3.89E-07 -3.92E-07 -3.90E-07 -3.95E-07 -3.72E-07 -3.76E-07 -3.70E-07 -3.70E-07 -3.27E-07 -3.27E-07 50 -3.65E-07 -3.87E-07 -3.84E-07 -4.07E-07 -3.78E-07 -3.83E-07 -3.60E-07 -4.01E-07 -4.02E-07 -3.85E-07 -3.72E-07 -3.27E-07 -3.59E-07 -3.68E-07 -3.72E-07 -3.76E-07 -3.84E-07 1.72E-08 1.75E-08 1.45E-08 1.43E-08 1.52E-08 -3.12E-07 -3.19E-07 -3.32E-07 -3.37E-07 -3.42E-07 -4.07E-07 -4.16E-07 -4.12E-07 -4.15E-07 -4.26E-07 -3.59E-07 1.84E-08 -3.09E-07 -4.10E-07 -7.15E-07 PASS 7.15E-07 PASS -3.67E-07 1.80E-08 -3.17E-07 -4.16E-07 -7.65E-07 PASS 7.65E-07 PASS -3.74E-07 1.73E-08 -3.26E-07 -4.21E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 104 -3.78E-07 1.71E-08 -3.31E-07 -4.25E-07 -8.15E-07 PASS 8.15E-07 PASS -3.86E-07 1.70E-08 -3.40E-07 -4.33E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.47. Plot of -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 105 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.47. Raw data for -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.49E-07 -3.64E-07 -3.59E-07 -3.79E-07 -3.46E-07 -3.57E-07 -3.24E-07 -3.71E-07 -3.81E-07 -3.57E-07 -3.72E-07 -3.36E-07 Total 10 -3.52E-07 -3.71E-07 -3.65E-07 -3.93E-07 -3.53E-07 -3.64E-07 -3.32E-07 -3.77E-07 -3.87E-07 -3.63E-07 -3.74E-07 -3.37E-07 Dose (krad(Si)) 20 30 -3.61E-07 -3.65E-07 -3.77E-07 -3.79E-07 -3.70E-07 -3.71E-07 -3.92E-07 -3.95E-07 -3.58E-07 -3.61E-07 -3.70E-07 -3.74E-07 -3.37E-07 -3.47E-07 -3.86E-07 -3.89E-07 -3.93E-07 -3.97E-07 -3.69E-07 -3.74E-07 -3.70E-07 -3.71E-07 -3.36E-07 -3.36E-07 50 -3.72E-07 -3.86E-07 -3.82E-07 -4.04E-07 -3.69E-07 -3.82E-07 -3.55E-07 -3.98E-07 -4.06E-07 -3.84E-07 -3.71E-07 -3.36E-07 -3.59E-07 -3.67E-07 -3.72E-07 -3.74E-07 -3.83E-07 1.32E-08 1.68E-08 1.37E-08 1.36E-08 1.41E-08 -3.23E-07 -3.21E-07 -3.34E-07 -3.37E-07 -3.44E-07 -3.95E-07 -4.13E-07 -4.09E-07 -4.12E-07 -4.21E-07 -3.58E-07 2.16E-08 -2.99E-07 -4.17E-07 -7.15E-07 PASS 7.15E-07 PASS -3.65E-07 2.08E-08 -3.08E-07 -4.22E-07 -7.65E-07 PASS 7.65E-07 PASS -3.71E-07 2.16E-08 -3.12E-07 -4.30E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 106 -3.76E-07 1.90E-08 -3.24E-07 -4.28E-07 -8.15E-07 PASS 8.15E-07 PASS -3.85E-07 1.96E-08 -3.31E-07 -4.39E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.48. Plot of -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 107 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.48. Raw data for -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.55E-07 -3.68E-07 -3.68E-07 -3.73E-07 -3.33E-07 -3.40E-07 -3.32E-07 -3.70E-07 -3.76E-07 -3.55E-07 -3.61E-07 -3.53E-07 Total 10 -3.59E-07 -3.74E-07 -3.74E-07 -3.86E-07 -3.46E-07 -3.53E-07 -3.40E-07 -3.76E-07 -3.82E-07 -3.63E-07 -3.64E-07 -3.54E-07 Dose (krad(Si)) 20 30 -3.69E-07 -3.72E-07 -3.81E-07 -3.83E-07 -3.79E-07 -3.82E-07 -3.84E-07 -3.89E-07 -3.50E-07 -3.54E-07 -3.59E-07 -3.61E-07 -3.52E-07 -3.56E-07 -3.84E-07 -3.87E-07 -3.91E-07 -3.93E-07 -3.67E-07 -3.72E-07 -3.59E-07 -3.60E-07 -3.51E-07 -3.52E-07 50 -3.82E-07 -3.92E-07 -3.94E-07 -3.97E-07 -3.64E-07 -3.71E-07 -3.64E-07 -3.96E-07 -4.04E-07 -3.80E-07 -3.60E-07 -3.52E-07 -3.59E-07 -3.68E-07 -3.73E-07 -3.76E-07 -3.86E-07 1.61E-08 1.55E-08 1.41E-08 1.36E-08 1.36E-08 -3.15E-07 -3.25E-07 -3.34E-07 -3.39E-07 -3.48E-07 -4.04E-07 -4.10E-07 -4.11E-07 -4.13E-07 -4.23E-07 -3.55E-07 1.90E-08 -3.03E-07 -4.07E-07 -7.15E-07 PASS 7.15E-07 PASS -3.63E-07 1.70E-08 -3.16E-07 -4.09E-07 -7.65E-07 PASS 7.65E-07 PASS -3.71E-07 1.63E-08 -3.26E-07 -4.15E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 108 -3.74E-07 1.59E-08 -3.30E-07 -4.18E-07 -8.15E-07 PASS 8.15E-07 PASS -3.83E-07 1.67E-08 -3.37E-07 -4.29E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.49. Plot of -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 109 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.49. Raw data for -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.58E-07 -3.65E-07 -3.63E-07 -3.76E-07 -3.37E-07 -3.35E-07 -3.30E-07 -3.74E-07 -3.69E-07 -3.59E-07 -3.59E-07 -3.51E-07 Total 10 -3.60E-07 -3.72E-07 -3.70E-07 -3.87E-07 -3.49E-07 -3.48E-07 -3.38E-07 -3.80E-07 -3.76E-07 -3.65E-07 -3.62E-07 -3.54E-07 Dose (krad(Si)) 20 30 -3.69E-07 -3.73E-07 -3.79E-07 -3.81E-07 -3.74E-07 -3.77E-07 -3.86E-07 -3.91E-07 -3.54E-07 -3.59E-07 -3.53E-07 -3.57E-07 -3.48E-07 -3.52E-07 -3.88E-07 -3.92E-07 -3.85E-07 -3.88E-07 -3.71E-07 -3.75E-07 -3.57E-07 -3.58E-07 -3.50E-07 -3.52E-07 50 -3.79E-07 -3.89E-07 -3.86E-07 -4.01E-07 -3.67E-07 -3.66E-07 -3.61E-07 -3.99E-07 -3.99E-07 -3.84E-07 -3.59E-07 -3.50E-07 -3.60E-07 -3.68E-07 -3.72E-07 -3.76E-07 -3.84E-07 1.42E-08 1.44E-08 1.19E-08 1.16E-08 1.23E-08 -3.21E-07 -3.28E-07 -3.40E-07 -3.44E-07 -3.51E-07 -3.99E-07 -4.07E-07 -4.05E-07 -4.08E-07 -4.18E-07 -3.54E-07 1.98E-08 -2.99E-07 -4.08E-07 -7.15E-07 PASS 7.15E-07 PASS -3.61E-07 1.80E-08 -3.12E-07 -4.11E-07 -7.65E-07 PASS 7.65E-07 PASS -3.69E-07 1.80E-08 -3.20E-07 -4.18E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 110 -3.73E-07 1.77E-08 -3.24E-07 -4.22E-07 -8.15E-07 PASS 8.15E-07 PASS -3.82E-07 1.80E-08 -3.32E-07 -4.31E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.50. Plot of -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 111 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.50. Raw data for -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.48E-07 -3.70E-07 -3.63E-07 -3.87E-07 -3.56E-07 -3.57E-07 -3.26E-07 -3.75E-07 -3.76E-07 -3.62E-07 -3.71E-07 -3.31E-07 Total 10 -3.52E-07 -3.77E-07 -3.68E-07 -3.99E-07 -3.66E-07 -3.66E-07 -3.34E-07 -3.80E-07 -3.82E-07 -3.68E-07 -3.75E-07 -3.32E-07 Dose (krad(Si)) 20 30 -3.60E-07 -3.65E-07 -3.82E-07 -3.86E-07 -3.73E-07 -3.77E-07 -3.96E-07 -4.01E-07 -3.72E-07 -3.78E-07 -3.73E-07 -3.77E-07 -3.40E-07 -3.50E-07 -3.89E-07 -3.94E-07 -3.89E-07 -3.92E-07 -3.73E-07 -3.78E-07 -3.70E-07 -3.72E-07 -3.31E-07 -3.31E-07 50 -3.73E-07 -3.95E-07 -3.87E-07 -4.11E-07 -3.87E-07 -3.85E-07 -3.58E-07 -4.02E-07 -4.00E-07 -3.86E-07 -3.70E-07 -3.31E-07 -3.65E-07 -3.72E-07 -3.77E-07 -3.81E-07 -3.91E-07 1.48E-08 1.71E-08 1.34E-08 1.35E-08 1.40E-08 -3.24E-07 -3.26E-07 -3.40E-07 -3.44E-07 -3.52E-07 -4.05E-07 -4.19E-07 -4.13E-07 -4.18E-07 -4.29E-07 -3.59E-07 2.01E-08 -3.04E-07 -4.14E-07 -7.15E-07 PASS 7.15E-07 PASS -3.66E-07 1.91E-08 -3.13E-07 -4.18E-07 -7.65E-07 PASS 7.65E-07 PASS -3.73E-07 2.01E-08 -3.18E-07 -4.28E-07 -8.15E-07 PASS 8.15E-07 PASS An ISO 9001:2008 and DSCC Certified Company 112 -3.78E-07 1.76E-08 -3.30E-07 -4.26E-07 -8.15E-07 PASS 8.15E-07 PASS -3.86E-07 1.77E-08 -3.38E-07 -4.35E-07 -8.65E-07 PASS 8.65E-07 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.51. Plot of Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 113 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.51. Raw data for Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High1 1 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=0mA Device 0 10 20 30 50 284 6.51E-03 6.61E-03 6.57E-03 6.53E-03 6.87E-03 303 6.46E-03 6.47E-03 6.68E-03 6.74E-03 6.65E-03 314 6.49E-03 6.57E-03 6.57E-03 6.46E-03 6.67E-03 331 6.68E-03 6.71E-03 6.68E-03 6.78E-03 6.72E-03 368 6.36E-03 6.27E-03 6.43E-03 6.58E-03 6.62E-03 404 6.31E-03 6.36E-03 6.45E-03 6.37E-03 6.41E-03 445 6.31E-03 6.42E-03 6.40E-03 6.48E-03 6.48E-03 474 6.61E-03 6.66E-03 6.72E-03 6.58E-03 6.68E-03 500 6.59E-03 6.73E-03 6.72E-03 6.73E-03 6.89E-03 518 6.56E-03 6.47E-03 6.75E-03 6.71E-03 6.72E-03 524 6.63E-03 6.49E-03 6.53E-03 6.58E-03 6.45E-03 558 6.36E-03 6.41E-03 6.48E-03 6.44E-03 6.33E-03 Biased Statistics Average Biased 6.50E-03 6.53E-03 6.59E-03 6.62E-03 6.71E-03 Std Dev Biased 1.16E-04 1.67E-04 1.03E-04 1.37E-04 9.86E-05 Ps90%/90% (+KTL) Biased 6.82E-03 6.98E-03 6.87E-03 6.99E-03 6.98E-03 Ps90%/90% (-KTL) Biased 6.18E-03 6.07E-03 6.30E-03 6.24E-03 6.44E-03 Un-Biased Statistics Average Un-Biased 6.48E-03 6.53E-03 6.61E-03 6.57E-03 6.64E-03 Std Dev Un-Biased 1.53E-04 1.59E-04 1.68E-04 1.53E-04 1.93E-04 Ps90%/90% (+KTL) Un-Biased 6.89E-03 6.96E-03 7.07E-03 6.99E-03 7.17E-03 Ps90%/90% (-KTL) Un-Biased 6.06E-03 6.09E-03 6.15E-03 6.16E-03 6.11E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 114 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.52. Plot of Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 115 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.52. Raw data for Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High1 2 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=0mA Device 0 10 20 30 50 284 6.71E-03 6.76E-03 6.74E-03 6.74E-03 6.89E-03 303 6.64E-03 6.64E-03 6.63E-03 6.72E-03 6.82E-03 314 6.46E-03 6.46E-03 6.52E-03 6.56E-03 6.57E-03 331 6.90E-03 6.86E-03 6.63E-03 6.95E-03 7.14E-03 368 6.71E-03 6.59E-03 6.70E-03 6.68E-03 6.80E-03 404 6.63E-03 6.47E-03 6.55E-03 6.69E-03 6.62E-03 445 6.68E-03 6.66E-03 6.82E-03 6.75E-03 6.90E-03 474 6.58E-03 6.61E-03 6.79E-03 6.78E-03 6.87E-03 500 6.63E-03 6.61E-03 6.75E-03 6.80E-03 6.94E-03 518 6.64E-03 6.66E-03 6.74E-03 6.78E-03 6.85E-03 524 6.71E-03 6.62E-03 6.55E-03 6.83E-03 6.62E-03 558 6.39E-03 6.36E-03 6.53E-03 6.46E-03 6.53E-03 Biased Statistics Average Biased 6.68E-03 6.66E-03 6.64E-03 6.73E-03 6.84E-03 Std Dev Biased 1.58E-04 1.54E-04 8.38E-05 1.41E-04 2.05E-04 Ps90%/90% (+KTL) Biased 7.12E-03 7.09E-03 6.87E-03 7.12E-03 7.40E-03 Ps90%/90% (-KTL) Biased 6.25E-03 6.24E-03 6.41E-03 6.34E-03 6.28E-03 Un-Biased Statistics Average Un-Biased 6.63E-03 6.60E-03 6.73E-03 6.76E-03 6.84E-03 Std Dev Un-Biased 3.56E-05 7.79E-05 1.06E-04 4.30E-05 1.25E-04 Ps90%/90% (+KTL) Un-Biased 6.73E-03 6.82E-03 7.02E-03 6.88E-03 7.18E-03 Ps90%/90% (-KTL) Un-Biased 6.53E-03 6.39E-03 6.44E-03 6.64E-03 6.49E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 116 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.53. Plot of Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 117 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.53. Raw data for Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High1 3 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=0mA Device 0 10 20 30 50 284 6.79E-03 6.69E-03 6.63E-03 6.82E-03 6.94E-03 303 6.59E-03 6.64E-03 6.67E-03 6.70E-03 6.92E-03 314 6.36E-03 6.49E-03 6.55E-03 6.61E-03 6.58E-03 331 6.91E-03 6.93E-03 6.70E-03 6.90E-03 7.02E-03 368 6.61E-03 6.66E-03 6.79E-03 6.66E-03 6.75E-03 404 6.51E-03 6.54E-03 6.55E-03 6.56E-03 6.58E-03 445 6.69E-03 6.76E-03 6.70E-03 6.69E-03 6.95E-03 474 6.64E-03 6.69E-03 6.79E-03 6.83E-03 6.90E-03 500 6.64E-03 6.68E-03 6.82E-03 6.88E-03 6.90E-03 518 6.78E-03 6.64E-03 6.74E-03 6.86E-03 6.94E-03 524 6.76E-03 6.64E-03 6.72E-03 6.76E-03 6.67E-03 558 6.49E-03 6.49E-03 6.53E-03 6.63E-03 6.46E-03 Biased Statistics Average Biased 6.65E-03 6.68E-03 6.67E-03 6.74E-03 6.84E-03 Std Dev Biased 2.10E-04 1.59E-04 8.84E-05 1.19E-04 1.76E-04 Ps90%/90% (+KTL) Biased 7.23E-03 7.12E-03 6.91E-03 7.06E-03 7.33E-03 Ps90%/90% (-KTL) Biased 6.08E-03 6.25E-03 6.43E-03 6.41E-03 6.36E-03 Un-Biased Statistics Average Un-Biased 6.65E-03 6.66E-03 6.72E-03 6.76E-03 6.85E-03 Std Dev Un-Biased 9.78E-05 8.07E-05 1.06E-04 1.36E-04 1.55E-04 Ps90%/90% (+KTL) Un-Biased 6.92E-03 6.88E-03 7.01E-03 7.14E-03 7.28E-03 Ps90%/90% (-KTL) Un-Biased 6.38E-03 6.44E-03 6.43E-03 6.39E-03 6.43E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 118 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.54. Plot of Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 119 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.54. Raw data for Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High1 4 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=0mA Device 0 10 20 30 50 284 6.78E-03 6.74E-03 6.85E-03 6.90E-03 6.97E-03 303 6.66E-03 6.74E-03 6.72E-03 6.77E-03 6.94E-03 314 6.61E-03 6.76E-03 6.68E-03 6.66E-03 6.92E-03 331 6.83E-03 6.89E-03 6.80E-03 6.95E-03 7.04E-03 368 6.56E-03 6.57E-03 6.62E-03 6.59E-03 6.73E-03 404 6.52E-03 6.44E-03 6.52E-03 6.66E-03 6.55E-03 445 6.61E-03 6.44E-03 6.50E-03 6.46E-03 6.73E-03 474 6.52E-03 6.71E-03 6.70E-03 6.81E-03 6.95E-03 500 6.76E-03 6.88E-03 6.80E-03 6.85E-03 6.99E-03 518 6.71E-03 6.81E-03 6.70E-03 6.85E-03 6.92E-03 524 6.68E-03 6.76E-03 6.70E-03 6.71E-03 6.68E-03 558 6.54E-03 6.49E-03 6.58E-03 6.54E-03 6.43E-03 Biased Statistics Average Biased 6.69E-03 6.74E-03 6.73E-03 6.77E-03 6.92E-03 Std Dev Biased 1.14E-04 1.14E-04 9.21E-05 1.53E-04 1.16E-04 Ps90%/90% (+KTL) Biased 7.00E-03 7.05E-03 6.99E-03 7.19E-03 7.24E-03 Ps90%/90% (-KTL) Biased 6.38E-03 6.43E-03 6.48E-03 6.35E-03 6.60E-03 Un-Biased Statistics Average Un-Biased 6.62E-03 6.66E-03 6.64E-03 6.73E-03 6.83E-03 Std Dev Un-Biased 1.09E-04 2.06E-04 1.29E-04 1.68E-04 1.85E-04 Ps90%/90% (+KTL) Un-Biased 6.92E-03 7.22E-03 7.00E-03 7.19E-03 7.33E-03 Ps90%/90% (-KTL) Un-Biased 6.32E-03 6.09E-03 6.29E-03 6.27E-03 6.32E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 120 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.55. Plot of Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 121 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.55. Raw data for Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High2 1 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=1mA Device 0 10 20 30 50 284 7.47E-02 7.57E-02 7.57E-02 7.62E-02 7.69E-02 303 7.54E-02 7.60E-02 7.66E-02 7.70E-02 7.77E-02 314 7.40E-02 7.46E-02 7.53E-02 7.57E-02 7.62E-02 331 7.59E-02 7.71E-02 7.73E-02 7.77E-02 7.82E-02 368 7.33E-02 7.41E-02 7.48E-02 7.51E-02 7.55E-02 404 7.10E-02 7.12E-02 7.15E-02 7.18E-02 7.21E-02 445 7.19E-02 7.20E-02 7.23E-02 7.28E-02 7.29E-02 474 7.54E-02 7.54E-02 7.56E-02 7.59E-02 7.65E-02 500 7.60E-02 7.61E-02 7.63E-02 7.66E-02 7.70E-02 518 7.51E-02 7.52E-02 7.54E-02 7.59E-02 7.61E-02 524 7.40E-02 7.39E-02 7.41E-02 7.43E-02 7.40E-02 558 7.24E-02 7.24E-02 7.24E-02 7.24E-02 7.25E-02 Biased Statistics Average Biased 7.46E-02 7.55E-02 7.59E-02 7.63E-02 7.69E-02 Std Dev Biased 1.04E-03 1.18E-03 1.02E-03 1.04E-03 1.09E-03 Ps90%/90% (+KTL) Biased 7.75E-02 7.87E-02 7.87E-02 7.92E-02 7.99E-02 Ps90%/90% (-KTL) Biased 7.18E-02 7.23E-02 7.32E-02 7.35E-02 7.39E-02 Un-Biased Statistics Average Un-Biased 7.39E-02 7.40E-02 7.42E-02 7.46E-02 7.49E-02 Std Dev Un-Biased 2.25E-03 2.20E-03 2.16E-03 2.13E-03 2.24E-03 Ps90%/90% (+KTL) Un-Biased 8.01E-02 8.00E-02 8.02E-02 8.04E-02 8.11E-02 Ps90%/90% (-KTL) Un-Biased 6.77E-02 6.79E-02 6.83E-02 6.88E-02 6.88E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 122 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.56. Plot of Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 123 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.56. Raw data for Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High2 2 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=1mA Device 0 10 20 30 50 284 7.36E-02 7.48E-02 7.49E-02 7.52E-02 7.59E-02 303 7.44E-02 7.51E-02 7.59E-02 7.62E-02 7.67E-02 314 7.07E-02 7.13E-02 7.18E-02 7.22E-02 7.28E-02 331 7.62E-02 7.73E-02 7.77E-02 7.78E-02 7.83E-02 368 7.31E-02 7.37E-02 7.45E-02 7.47E-02 7.51E-02 404 7.20E-02 7.23E-02 7.27E-02 7.26E-02 7.31E-02 445 7.45E-02 7.46E-02 7.50E-02 7.54E-02 7.56E-02 474 7.39E-02 7.41E-02 7.43E-02 7.46E-02 7.49E-02 500 7.49E-02 7.53E-02 7.54E-02 7.58E-02 7.64E-02 518 7.49E-02 7.52E-02 7.54E-02 7.57E-02 7.60E-02 524 7.40E-02 7.39E-02 7.38E-02 7.38E-02 7.39E-02 558 7.09E-02 7.05E-02 7.07E-02 7.06E-02 7.09E-02 Biased Statistics Average Biased 7.36E-02 7.44E-02 7.49E-02 7.52E-02 7.57E-02 Std Dev Biased 2.00E-03 2.18E-03 2.15E-03 2.06E-03 2.04E-03 Ps90%/90% (+KTL) Biased 7.91E-02 8.04E-02 8.08E-02 8.09E-02 8.13E-02 Ps90%/90% (-KTL) Biased 6.81E-02 6.85E-02 6.90E-02 6.95E-02 7.01E-02 Un-Biased Statistics Average Un-Biased 7.40E-02 7.43E-02 7.46E-02 7.48E-02 7.52E-02 Std Dev Un-Biased 1.22E-03 1.23E-03 1.15E-03 1.30E-03 1.28E-03 Ps90%/90% (+KTL) Un-Biased 7.74E-02 7.77E-02 7.77E-02 7.84E-02 7.87E-02 Ps90%/90% (-KTL) Un-Biased 7.07E-02 7.09E-02 7.14E-02 7.13E-02 7.17E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 124 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.57. Plot of Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 125 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.57. Raw data for Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High2 3 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=1mA Device 0 10 20 30 50 284 7.39E-02 7.50E-02 7.51E-02 7.54E-02 7.61E-02 303 7.42E-02 7.48E-02 7.56E-02 7.58E-02 7.64E-02 314 7.06E-02 7.14E-02 7.20E-02 7.25E-02 7.30E-02 331 7.64E-02 7.77E-02 7.77E-02 7.78E-02 7.85E-02 368 7.31E-02 7.40E-02 7.46E-02 7.49E-02 7.52E-02 404 7.21E-02 7.20E-02 7.27E-02 7.28E-02 7.32E-02 445 7.44E-02 7.45E-02 7.48E-02 7.53E-02 7.56E-02 474 7.43E-02 7.47E-02 7.47E-02 7.50E-02 7.56E-02 500 7.48E-02 7.50E-02 7.53E-02 7.56E-02 7.60E-02 518 7.52E-02 7.52E-02 7.57E-02 7.57E-02 7.61E-02 524 7.43E-02 7.42E-02 7.45E-02 7.42E-02 7.43E-02 558 7.08E-02 7.07E-02 7.09E-02 7.07E-02 7.09E-02 Biased Statistics Average Biased 7.36E-02 7.46E-02 7.50E-02 7.53E-02 7.58E-02 Std Dev Biased 2.09E-03 2.26E-03 2.06E-03 1.92E-03 1.97E-03 Ps90%/90% (+KTL) Biased 7.94E-02 8.08E-02 8.06E-02 8.06E-02 8.12E-02 Ps90%/90% (-KTL) Biased 6.79E-02 6.84E-02 6.94E-02 7.00E-02 7.04E-02 Un-Biased Statistics Average Un-Biased 7.42E-02 7.43E-02 7.46E-02 7.49E-02 7.53E-02 Std Dev Un-Biased 1.19E-03 1.30E-03 1.17E-03 1.20E-03 1.19E-03 Ps90%/90% (+KTL) Un-Biased 7.75E-02 7.78E-02 7.78E-02 7.82E-02 7.85E-02 Ps90%/90% (-KTL) Un-Biased 7.09E-02 7.07E-02 7.14E-02 7.16E-02 7.20E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 126 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.58. Plot of Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 127 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.58. Raw data for Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High2 4 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=1mA Device 0 10 20 30 50 284 7.46E-02 7.59E-02 7.59E-02 7.63E-02 7.69E-02 303 7.58E-02 7.64E-02 7.68E-02 7.72E-02 7.76E-02 314 7.43E-02 7.52E-02 7.58E-02 7.63E-02 7.66E-02 331 7.59E-02 7.72E-02 7.72E-02 7.76E-02 7.80E-02 368 7.34E-02 7.39E-02 7.47E-02 7.50E-02 7.54E-02 404 7.10E-02 7.12E-02 7.15E-02 7.18E-02 7.21E-02 445 7.17E-02 7.17E-02 7.20E-02 7.24E-02 7.26E-02 474 7.48E-02 7.51E-02 7.53E-02 7.56E-02 7.59E-02 500 7.63E-02 7.66E-02 7.65E-02 7.71E-02 7.73E-02 518 7.48E-02 7.49E-02 7.54E-02 7.56E-02 7.60E-02 524 7.42E-02 7.41E-02 7.43E-02 7.44E-02 7.45E-02 558 7.21E-02 7.19E-02 7.23E-02 7.22E-02 7.22E-02 Biased Statistics Average Biased 7.48E-02 7.57E-02 7.61E-02 7.65E-02 7.69E-02 Std Dev Biased 1.04E-03 1.25E-03 9.71E-04 9.92E-04 1.02E-03 Ps90%/90% (+KTL) Biased 7.77E-02 7.91E-02 7.88E-02 7.92E-02 7.97E-02 Ps90%/90% (-KTL) Biased 7.19E-02 7.23E-02 7.34E-02 7.38E-02 7.41E-02 Un-Biased Statistics Average Un-Biased 7.37E-02 7.39E-02 7.41E-02 7.45E-02 7.48E-02 Std Dev Un-Biased 2.28E-03 2.33E-03 2.25E-03 2.30E-03 2.30E-03 Ps90%/90% (+KTL) Un-Biased 8.00E-02 8.03E-02 8.03E-02 8.08E-02 8.11E-02 Ps90%/90% (-KTL) Un-Biased 6.75E-02 6.75E-02 6.80E-02 6.82E-02 6.85E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 128 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.59. Plot of Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 129 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.59. Raw data for Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High3 1 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=10mA Device 0 10 20 30 50 284 3.78E-01 3.81E-01 3.80E-01 3.82E-01 3.84E-01 303 3.80E-01 3.82E-01 3.84E-01 3.85E-01 3.87E-01 314 3.75E-01 3.76E-01 3.78E-01 3.79E-01 3.82E-01 331 3.83E-01 3.85E-01 3.86E-01 3.87E-01 3.89E-01 368 3.72E-01 3.72E-01 3.75E-01 3.76E-01 3.77E-01 404 3.60E-01 3.60E-01 3.62E-01 3.63E-01 3.64E-01 445 3.67E-01 3.67E-01 3.68E-01 3.70E-01 3.71E-01 474 3.79E-01 3.80E-01 3.81E-01 3.82E-01 3.84E-01 500 3.83E-01 3.83E-01 3.84E-01 3.85E-01 3.87E-01 518 3.79E-01 3.79E-01 3.81E-01 3.82E-01 3.84E-01 524 3.76E-01 3.75E-01 3.76E-01 3.75E-01 3.76E-01 558 3.70E-01 3.69E-01 3.69E-01 3.69E-01 3.69E-01 Biased Statistics Average Biased 3.78E-01 3.79E-01 3.81E-01 3.82E-01 3.84E-01 Std Dev Biased 4.32E-03 5.15E-03 4.39E-03 4.66E-03 4.68E-03 Ps90%/90% (+KTL) Biased 3.89E-01 3.93E-01 3.93E-01 3.94E-01 3.97E-01 Ps90%/90% (-KTL) Biased 3.66E-01 3.65E-01 3.69E-01 3.69E-01 3.71E-01 Un-Biased Statistics Average Un-Biased 3.74E-01 3.74E-01 3.75E-01 3.76E-01 3.78E-01 Std Dev Un-Biased 9.52E-03 9.70E-03 9.62E-03 9.61E-03 9.79E-03 Ps90%/90% (+KTL) Un-Biased 4.00E-01 4.01E-01 4.02E-01 4.03E-01 4.05E-01 Ps90%/90% (-KTL) Un-Biased 3.48E-01 3.47E-01 3.49E-01 3.50E-01 3.51E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 130 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.60. Plot of Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 131 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.60. Raw data for Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High3 2 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=10mA Device 0 10 20 30 50 284 3.74E-01 3.78E-01 3.78E-01 3.79E-01 3.81E-01 303 3.77E-01 3.78E-01 3.80E-01 3.81E-01 3.83E-01 314 3.58E-01 3.59E-01 3.61E-01 3.62E-01 3.64E-01 331 3.85E-01 3.87E-01 3.88E-01 3.88E-01 3.91E-01 368 3.73E-01 3.74E-01 3.76E-01 3.77E-01 3.78E-01 404 3.69E-01 3.69E-01 3.71E-01 3.71E-01 3.73E-01 445 3.78E-01 3.78E-01 3.80E-01 3.81E-01 3.83E-01 474 3.74E-01 3.75E-01 3.75E-01 3.76E-01 3.79E-01 500 3.79E-01 3.80E-01 3.81E-01 3.82E-01 3.84E-01 518 3.79E-01 3.79E-01 3.81E-01 3.82E-01 3.83E-01 524 3.76E-01 3.74E-01 3.76E-01 3.75E-01 3.76E-01 558 3.62E-01 3.61E-01 3.62E-01 3.62E-01 3.62E-01 Biased Statistics Average Biased 3.73E-01 3.75E-01 3.76E-01 3.77E-01 3.79E-01 Std Dev Biased 9.48E-03 1.02E-02 9.80E-03 9.79E-03 9.88E-03 Ps90%/90% (+KTL) Biased 3.99E-01 4.03E-01 4.03E-01 4.04E-01 4.06E-01 Ps90%/90% (-KTL) Biased 3.47E-01 3.47E-01 3.50E-01 3.50E-01 3.52E-01 Un-Biased Statistics Average Un-Biased 3.76E-01 3.76E-01 3.78E-01 3.78E-01 3.80E-01 Std Dev Un-Biased 4.38E-03 4.33E-03 4.56E-03 4.86E-03 4.89E-03 Ps90%/90% (+KTL) Un-Biased 3.88E-01 3.88E-01 3.90E-01 3.92E-01 3.94E-01 Ps90%/90% (-KTL) Un-Biased 3.64E-01 3.64E-01 3.65E-01 3.65E-01 3.67E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 132 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.61. Plot of Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 133 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.61. Raw data for Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High3 3 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=10mA Device 0 10 20 30 50 284 3.75E-01 3.78E-01 3.78E-01 3.79E-01 3.81E-01 303 3.75E-01 3.77E-01 3.79E-01 3.80E-01 3.82E-01 314 3.59E-01 3.60E-01 3.62E-01 3.62E-01 3.64E-01 331 3.85E-01 3.87E-01 3.88E-01 3.89E-01 3.91E-01 368 3.74E-01 3.74E-01 3.77E-01 3.78E-01 3.79E-01 404 3.69E-01 3.69E-01 3.71E-01 3.71E-01 3.73E-01 445 3.78E-01 3.78E-01 3.80E-01 3.81E-01 3.83E-01 474 3.76E-01 3.76E-01 3.77E-01 3.78E-01 3.80E-01 500 3.79E-01 3.79E-01 3.80E-01 3.81E-01 3.83E-01 518 3.79E-01 3.80E-01 3.82E-01 3.83E-01 3.84E-01 524 3.77E-01 3.76E-01 3.77E-01 3.76E-01 3.77E-01 558 3.62E-01 3.61E-01 3.62E-01 3.61E-01 3.62E-01 Biased Statistics Average Biased 3.74E-01 3.75E-01 3.77E-01 3.78E-01 3.80E-01 Std Dev Biased 9.21E-03 9.87E-03 9.51E-03 9.61E-03 9.78E-03 Ps90%/90% (+KTL) Biased 3.99E-01 4.02E-01 4.03E-01 4.04E-01 4.07E-01 Ps90%/90% (-KTL) Biased 3.48E-01 3.48E-01 3.51E-01 3.51E-01 3.53E-01 Un-Biased Statistics Average Un-Biased 3.76E-01 3.77E-01 3.78E-01 3.79E-01 3.81E-01 Std Dev Un-Biased 4.29E-03 4.41E-03 4.37E-03 4.59E-03 4.71E-03 Ps90%/90% (+KTL) Un-Biased 3.88E-01 3.89E-01 3.90E-01 3.92E-01 3.94E-01 Ps90%/90% (-KTL) Un-Biased 3.64E-01 3.65E-01 3.66E-01 3.66E-01 3.68E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 134 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA 9.00E-01 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.62. Plot of Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 135 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.62. Raw data for Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High3 4 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=10mA Device 0 10 20 30 50 284 3.78E-01 3.82E-01 3.82E-01 3.83E-01 3.86E-01 303 3.81E-01 3.82E-01 3.84E-01 3.85E-01 3.88E-01 314 3.77E-01 3.78E-01 3.80E-01 3.81E-01 3.83E-01 331 3.83E-01 3.85E-01 3.86E-01 3.87E-01 3.90E-01 368 3.72E-01 3.72E-01 3.75E-01 3.76E-01 3.77E-01 404 3.60E-01 3.61E-01 3.62E-01 3.63E-01 3.64E-01 445 3.66E-01 3.66E-01 3.67E-01 3.69E-01 3.70E-01 474 3.77E-01 3.78E-01 3.78E-01 3.79E-01 3.82E-01 500 3.84E-01 3.84E-01 3.85E-01 3.86E-01 3.89E-01 518 3.78E-01 3.79E-01 3.81E-01 3.82E-01 3.83E-01 524 3.77E-01 3.75E-01 3.77E-01 3.76E-01 3.77E-01 558 3.68E-01 3.67E-01 3.68E-01 3.68E-01 3.68E-01 Biased Statistics Average Biased 3.78E-01 3.80E-01 3.81E-01 3.83E-01 3.85E-01 Std Dev Biased 4.30E-03 5.02E-03 4.40E-03 4.50E-03 4.76E-03 Ps90%/90% (+KTL) Biased 3.90E-01 3.94E-01 3.94E-01 3.95E-01 3.98E-01 Ps90%/90% (-KTL) Biased 3.66E-01 3.66E-01 3.69E-01 3.70E-01 3.72E-01 Un-Biased Statistics Average Un-Biased 3.73E-01 3.73E-01 3.75E-01 3.76E-01 3.78E-01 Std Dev Un-Biased 9.58E-03 9.68E-03 9.51E-03 9.62E-03 9.98E-03 Ps90%/90% (+KTL) Un-Biased 3.99E-01 4.00E-01 4.01E-01 4.02E-01 4.05E-01 Ps90%/90% (-KTL) Un-Biased 3.47E-01 3.47E-01 3.49E-01 3.49E-01 3.50E-01 Specification MAX 8.00E-01 8.00E-01 8.00E-01 8.00E-01 8.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 136 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.63. Plot of Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 137 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.63. Raw data for Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low1 1 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=0mA Device 0 10 20 30 50 284 1.86E-02 1.91E-02 1.91E-02 1.90E-02 1.93E-02 303 1.80E-02 1.82E-02 1.84E-02 1.84E-02 1.84E-02 314 1.83E-02 1.84E-02 1.86E-02 1.86E-02 1.87E-02 331 1.78E-02 1.79E-02 1.80E-02 1.80E-02 1.82E-02 368 1.83E-02 1.84E-02 1.87E-02 1.86E-02 1.87E-02 404 1.87E-02 1.85E-02 1.87E-02 1.90E-02 1.90E-02 445 1.88E-02 1.90E-02 1.89E-02 1.91E-02 1.93E-02 474 1.81E-02 1.82E-02 1.84E-02 1.85E-02 1.85E-02 500 1.80E-02 1.81E-02 1.82E-02 1.82E-02 1.85E-02 518 1.82E-02 1.83E-02 1.84E-02 1.85E-02 1.86E-02 524 1.82E-02 1.82E-02 1.81E-02 1.83E-02 1.82E-02 558 1.84E-02 1.85E-02 1.86E-02 1.85E-02 1.85E-02 Biased Statistics Average Biased 1.82E-02 1.84E-02 1.85E-02 1.85E-02 1.87E-02 Std Dev Biased 3.20E-04 4.29E-04 3.89E-04 3.66E-04 4.22E-04 Ps90%/90% (+KTL) Biased 1.91E-02 1.96E-02 1.96E-02 1.95E-02 1.98E-02 Ps90%/90% (-KTL) Biased 1.73E-02 1.72E-02 1.75E-02 1.75E-02 1.75E-02 Un-Biased Statistics Average Un-Biased 1.84E-02 1.84E-02 1.85E-02 1.87E-02 1.88E-02 Std Dev Un-Biased 3.55E-04 3.56E-04 2.82E-04 3.70E-04 3.36E-04 Ps90%/90% (+KTL) Un-Biased 1.93E-02 1.94E-02 1.93E-02 1.97E-02 1.97E-02 Ps90%/90% (-KTL) Un-Biased 1.74E-02 1.75E-02 1.77E-02 1.76E-02 1.78E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 138 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.64. Plot of Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 139 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.64. Raw data for Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low1 2 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=0mA Device 0 10 20 30 50 284 1.86E-02 1.89E-02 1.89E-02 1.90E-02 1.90E-02 303 1.81E-02 1.81E-02 1.82E-02 1.85E-02 1.85E-02 314 1.86E-02 1.87E-02 1.88E-02 1.89E-02 1.91E-02 331 1.82E-02 1.84E-02 1.84E-02 1.85E-02 1.87E-02 368 1.89E-02 1.91E-02 1.92E-02 1.92E-02 1.94E-02 404 1.90E-02 1.90E-02 1.92E-02 1.92E-02 1.94E-02 445 1.94E-02 1.94E-02 1.94E-02 1.97E-02 1.97E-02 474 1.79E-02 1.79E-02 1.80E-02 1.82E-02 1.83E-02 500 1.83E-02 1.83E-02 1.84E-02 1.85E-02 1.87E-02 518 1.85E-02 1.87E-02 1.87E-02 1.89E-02 1.90E-02 524 1.89E-02 1.89E-02 1.88E-02 1.89E-02 1.89E-02 558 1.84E-02 1.86E-02 1.86E-02 1.85E-02 1.86E-02 Biased Statistics Average Biased 1.85E-02 1.86E-02 1.87E-02 1.88E-02 1.89E-02 Std Dev Biased 3.32E-04 3.93E-04 3.83E-04 2.93E-04 3.66E-04 Ps90%/90% (+KTL) Biased 1.94E-02 1.97E-02 1.97E-02 1.96E-02 1.99E-02 Ps90%/90% (-KTL) Biased 1.75E-02 1.76E-02 1.76E-02 1.80E-02 1.79E-02 Un-Biased Statistics Average Un-Biased 1.86E-02 1.86E-02 1.87E-02 1.89E-02 1.90E-02 Std Dev Un-Biased 5.73E-04 5.73E-04 5.71E-04 6.07E-04 5.56E-04 Ps90%/90% (+KTL) Un-Biased 2.02E-02 2.02E-02 2.03E-02 2.06E-02 2.05E-02 Ps90%/90% (-KTL) Un-Biased 1.70E-02 1.71E-02 1.72E-02 1.72E-02 1.75E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 140 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.65. Plot of Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 141 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.65. Raw data for Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low1 3 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=0mA Device 0 10 20 30 50 284 1.81E-02 1.84E-02 1.84E-02 1.84E-02 1.86E-02 303 1.78E-02 1.79E-02 1.81E-02 1.83E-02 1.83E-02 314 1.85E-02 1.86E-02 1.88E-02 1.89E-02 1.90E-02 331 1.82E-02 1.83E-02 1.83E-02 1.84E-02 1.85E-02 368 1.88E-02 1.88E-02 1.90E-02 1.90E-02 1.91E-02 404 1.85E-02 1.85E-02 1.86E-02 1.88E-02 1.89E-02 445 1.87E-02 1.87E-02 1.88E-02 1.91E-02 1.93E-02 474 1.78E-02 1.79E-02 1.78E-02 1.79E-02 1.80E-02 500 1.81E-02 1.82E-02 1.82E-02 1.84E-02 1.85E-02 518 1.85E-02 1.84E-02 1.84E-02 1.86E-02 1.86E-02 524 1.86E-02 1.84E-02 1.87E-02 1.87E-02 1.85E-02 558 1.80E-02 1.78E-02 1.80E-02 1.80E-02 1.80E-02 Biased Statistics Average Biased 1.83E-02 1.84E-02 1.85E-02 1.86E-02 1.87E-02 Std Dev Biased 3.61E-04 3.21E-04 3.67E-04 3.24E-04 3.46E-04 Ps90%/90% (+KTL) Biased 1.93E-02 1.93E-02 1.95E-02 1.95E-02 1.96E-02 Ps90%/90% (-KTL) Biased 1.73E-02 1.75E-02 1.75E-02 1.77E-02 1.77E-02 Un-Biased Statistics Average Un-Biased 1.83E-02 1.83E-02 1.84E-02 1.86E-02 1.86E-02 Std Dev Un-Biased 3.90E-04 2.96E-04 3.82E-04 4.39E-04 4.52E-04 Ps90%/90% (+KTL) Un-Biased 1.94E-02 1.91E-02 1.94E-02 1.98E-02 1.99E-02 Ps90%/90% (-KTL) Un-Biased 1.72E-02 1.75E-02 1.73E-02 1.73E-02 1.74E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 142 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.66. Plot of Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 143 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.66. Raw data for Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low1 4 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=0mA Device 0 10 20 30 50 284 1.89E-02 1.91E-02 1.91E-02 1.93E-02 1.94E-02 303 1.84E-02 1.83E-02 1.85E-02 1.85E-02 1.88E-02 314 1.87E-02 1.88E-02 1.90E-02 1.91E-02 1.92E-02 331 1.81E-02 1.83E-02 1.83E-02 1.83E-02 1.86E-02 368 1.85E-02 1.85E-02 1.89E-02 1.88E-02 1.89E-02 404 1.86E-02 1.88E-02 1.89E-02 1.90E-02 1.91E-02 445 1.89E-02 1.91E-02 1.91E-02 1.92E-02 1.94E-02 474 1.81E-02 1.82E-02 1.82E-02 1.84E-02 1.88E-02 500 1.82E-02 1.84E-02 1.83E-02 1.84E-02 1.87E-02 518 1.85E-02 1.84E-02 1.84E-02 1.87E-02 1.86E-02 524 1.85E-02 1.83E-02 1.87E-02 1.85E-02 1.87E-02 558 1.88E-02 1.89E-02 1.88E-02 1.87E-02 1.89E-02 Biased Statistics Average Biased 1.85E-02 1.86E-02 1.87E-02 1.88E-02 1.90E-02 Std Dev Biased 3.13E-04 3.36E-04 3.48E-04 3.93E-04 3.10E-04 Ps90%/90% (+KTL) Biased 1.94E-02 1.95E-02 1.97E-02 1.99E-02 1.98E-02 Ps90%/90% (-KTL) Biased 1.77E-02 1.77E-02 1.78E-02 1.77E-02 1.81E-02 Un-Biased Statistics Average Un-Biased 1.85E-02 1.86E-02 1.86E-02 1.87E-02 1.89E-02 Std Dev Un-Biased 3.22E-04 3.51E-04 3.92E-04 3.38E-04 3.30E-04 Ps90%/90% (+KTL) Un-Biased 1.93E-02 1.95E-02 1.96E-02 1.97E-02 1.98E-02 Ps90%/90% (-KTL) Un-Biased 1.76E-02 1.76E-02 1.75E-02 1.78E-02 1.80E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 144 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.67. Plot of Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 145 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.67. Raw data for Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low2 1 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=1mA Device 0 10 20 30 50 284 5.31E-02 5.32E-02 5.33E-02 5.34E-02 5.36E-02 303 5.22E-02 5.23E-02 5.26E-02 5.28E-02 5.29E-02 314 5.25E-02 5.25E-02 5.26E-02 5.28E-02 5.30E-02 331 5.20E-02 5.22E-02 5.22E-02 5.22E-02 5.24E-02 368 5.21E-02 5.22E-02 5.25E-02 5.25E-02 5.28E-02 404 5.23E-02 5.22E-02 5.24E-02 5.24E-02 5.25E-02 445 5.26E-02 5.25E-02 5.26E-02 5.27E-02 5.29E-02 474 5.26E-02 5.24E-02 5.26E-02 5.27E-02 5.29E-02 500 5.24E-02 5.23E-02 5.23E-02 5.27E-02 5.28E-02 518 5.26E-02 5.26E-02 5.27E-02 5.26E-02 5.29E-02 524 5.22E-02 5.22E-02 5.25E-02 5.23E-02 5.23E-02 558 5.23E-02 5.22E-02 5.23E-02 5.20E-02 5.23E-02 Biased Statistics Average Biased 5.24E-02 5.25E-02 5.26E-02 5.27E-02 5.29E-02 Std Dev Biased 4.19E-04 4.18E-04 4.06E-04 4.50E-04 4.09E-04 Ps90%/90% (+KTL) Biased 5.35E-02 5.36E-02 5.37E-02 5.40E-02 5.41E-02 Ps90%/90% (-KTL) Biased 5.12E-02 5.13E-02 5.15E-02 5.15E-02 5.18E-02 Un-Biased Statistics Average Un-Biased 5.25E-02 5.24E-02 5.25E-02 5.26E-02 5.28E-02 Std Dev Un-Biased 1.28E-04 1.45E-04 1.40E-04 1.28E-04 1.64E-04 Ps90%/90% (+KTL) Un-Biased 5.28E-02 5.28E-02 5.29E-02 5.30E-02 5.32E-02 Ps90%/90% (-KTL) Un-Biased 5.21E-02 5.20E-02 5.21E-02 5.23E-02 5.23E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 146 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.68. Plot of Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 147 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.68. Raw data for Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low2 2 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=1mA Device 0 10 20 30 50 284 5.28E-02 5.33E-02 5.32E-02 5.31E-02 5.34E-02 303 5.23E-02 5.24E-02 5.27E-02 5.27E-02 5.28E-02 314 5.22E-02 5.24E-02 5.25E-02 5.27E-02 5.29E-02 331 5.31E-02 5.33E-02 5.32E-02 5.33E-02 5.36E-02 368 5.30E-02 5.30E-02 5.32E-02 5.34E-02 5.34E-02 404 5.28E-02 5.27E-02 5.29E-02 5.30E-02 5.31E-02 445 5.38E-02 5.37E-02 5.39E-02 5.41E-02 5.43E-02 474 5.24E-02 5.24E-02 5.25E-02 5.27E-02 5.28E-02 500 5.29E-02 5.28E-02 5.27E-02 5.29E-02 5.32E-02 518 5.30E-02 5.31E-02 5.31E-02 5.33E-02 5.36E-02 524 5.33E-02 5.32E-02 5.31E-02 5.33E-02 5.32E-02 558 5.23E-02 5.22E-02 5.24E-02 5.21E-02 5.23E-02 Biased Statistics Average Biased 5.27E-02 5.29E-02 5.29E-02 5.30E-02 5.32E-02 Std Dev Biased 4.14E-04 4.38E-04 3.44E-04 3.21E-04 3.51E-04 Ps90%/90% (+KTL) Biased 5.38E-02 5.41E-02 5.39E-02 5.39E-02 5.42E-02 Ps90%/90% (-KTL) Biased 5.16E-02 5.17E-02 5.20E-02 5.22E-02 5.23E-02 Un-Biased Statistics Average Un-Biased 5.30E-02 5.29E-02 5.30E-02 5.32E-02 5.34E-02 Std Dev Un-Biased 5.08E-04 4.84E-04 5.49E-04 5.51E-04 5.67E-04 Ps90%/90% (+KTL) Un-Biased 5.44E-02 5.43E-02 5.45E-02 5.47E-02 5.49E-02 Ps90%/90% (-KTL) Un-Biased 5.16E-02 5.16E-02 5.15E-02 5.17E-02 5.18E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 148 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.69. Plot of Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 149 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.69. Raw data for Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low2 3 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=1mA Device 0 10 20 30 50 284 5.22E-02 5.24E-02 5.22E-02 5.24E-02 5.25E-02 303 5.20E-02 5.19E-02 5.21E-02 5.22E-02 5.25E-02 314 5.21E-02 5.19E-02 5.23E-02 5.22E-02 5.25E-02 331 5.24E-02 5.25E-02 5.26E-02 5.28E-02 5.29E-02 368 5.24E-02 5.25E-02 5.28E-02 5.28E-02 5.30E-02 404 5.22E-02 5.21E-02 5.24E-02 5.25E-02 5.26E-02 445 5.28E-02 5.26E-02 5.28E-02 5.31E-02 5.32E-02 474 5.20E-02 5.18E-02 5.19E-02 5.22E-02 5.22E-02 500 5.23E-02 5.23E-02 5.23E-02 5.24E-02 5.27E-02 518 5.26E-02 5.25E-02 5.29E-02 5.30E-02 5.31E-02 524 5.28E-02 5.25E-02 5.28E-02 5.27E-02 5.29E-02 558 5.16E-02 5.14E-02 5.17E-02 5.15E-02 5.16E-02 Biased Statistics Average Biased 5.22E-02 5.23E-02 5.24E-02 5.25E-02 5.27E-02 Std Dev Biased 1.85E-04 3.16E-04 2.75E-04 3.13E-04 2.48E-04 Ps90%/90% (+KTL) Biased 5.27E-02 5.31E-02 5.32E-02 5.33E-02 5.34E-02 Ps90%/90% (-KTL) Biased 5.17E-02 5.14E-02 5.17E-02 5.16E-02 5.20E-02 Un-Biased Statistics Average Un-Biased 5.24E-02 5.23E-02 5.24E-02 5.26E-02 5.27E-02 Std Dev Un-Biased 3.40E-04 3.61E-04 3.95E-04 3.92E-04 4.16E-04 Ps90%/90% (+KTL) Un-Biased 5.33E-02 5.32E-02 5.35E-02 5.37E-02 5.39E-02 Ps90%/90% (-KTL) Un-Biased 5.14E-02 5.13E-02 5.14E-02 5.16E-02 5.16E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 150 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.70. Plot of Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 151 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.70. Raw data for Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low2 4 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=1mA Device 0 10 20 30 50 284 5.36E-02 5.41E-02 5.37E-02 5.38E-02 5.39E-02 303 5.29E-02 5.30E-02 5.32E-02 5.32E-02 5.33E-02 314 5.33E-02 5.32E-02 5.33E-02 5.33E-02 5.36E-02 331 5.28E-02 5.29E-02 5.28E-02 5.30E-02 5.32E-02 368 5.23E-02 5.24E-02 5.27E-02 5.28E-02 5.29E-02 404 5.26E-02 5.26E-02 5.27E-02 5.29E-02 5.31E-02 445 5.29E-02 5.29E-02 5.32E-02 5.34E-02 5.32E-02 474 5.29E-02 5.29E-02 5.28E-02 5.30E-02 5.34E-02 500 5.29E-02 5.30E-02 5.29E-02 5.31E-02 5.33E-02 518 5.29E-02 5.29E-02 5.30E-02 5.32E-02 5.34E-02 524 5.30E-02 5.27E-02 5.30E-02 5.30E-02 5.29E-02 558 5.30E-02 5.29E-02 5.29E-02 5.30E-02 5.30E-02 Biased Statistics Average Biased 5.30E-02 5.31E-02 5.31E-02 5.32E-02 5.34E-02 Std Dev Biased 4.97E-04 6.04E-04 4.17E-04 4.08E-04 3.84E-04 Ps90%/90% (+KTL) Biased 5.43E-02 5.48E-02 5.43E-02 5.43E-02 5.45E-02 Ps90%/90% (-KTL) Biased 5.16E-02 5.15E-02 5.20E-02 5.21E-02 5.24E-02 Un-Biased Statistics Average Un-Biased 5.29E-02 5.28E-02 5.29E-02 5.31E-02 5.33E-02 Std Dev Un-Biased 1.43E-04 1.32E-04 1.79E-04 1.98E-04 1.11E-04 Ps90%/90% (+KTL) Un-Biased 5.32E-02 5.32E-02 5.34E-02 5.37E-02 5.36E-02 Ps90%/90% (-KTL) Un-Biased 5.25E-02 5.25E-02 5.24E-02 5.26E-02 5.30E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 152 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.71. Plot of Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 153 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.71. Raw data for Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low3 1 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=10mA Device 0 10 20 30 50 284 2.22E-01 2.23E-01 2.22E-01 2.22E-01 2.23E-01 303 2.20E-01 2.20E-01 2.21E-01 2.21E-01 2.21E-01 314 2.22E-01 2.21E-01 2.21E-01 2.21E-01 2.22E-01 331 2.22E-01 2.21E-01 2.22E-01 2.22E-01 2.22E-01 368 2.17E-01 2.16E-01 2.18E-01 2.18E-01 2.18E-01 404 2.17E-01 2.17E-01 2.18E-01 2.18E-01 2.18E-01 445 2.19E-01 2.18E-01 2.19E-01 2.19E-01 2.19E-01 474 2.21E-01 2.21E-01 2.21E-01 2.21E-01 2.22E-01 500 2.22E-01 2.22E-01 2.21E-01 2.22E-01 2.22E-01 518 2.21E-01 2.21E-01 2.21E-01 2.22E-01 2.22E-01 524 2.22E-01 2.22E-01 2.22E-01 2.22E-01 2.22E-01 558 2.19E-01 2.18E-01 2.19E-01 2.19E-01 2.19E-01 Biased Statistics Average Biased 2.21E-01 2.20E-01 2.21E-01 2.21E-01 2.21E-01 Std Dev Biased 1.90E-03 2.43E-03 1.77E-03 1.85E-03 1.99E-03 Ps90%/90% (+KTL) Biased 2.26E-01 2.27E-01 2.26E-01 2.26E-01 2.27E-01 Ps90%/90% (-KTL) Biased 2.15E-01 2.14E-01 2.16E-01 2.16E-01 2.16E-01 Un-Biased Statistics Average Un-Biased 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.21E-01 Std Dev Un-Biased 1.96E-03 1.95E-03 1.73E-03 1.73E-03 1.93E-03 Ps90%/90% (+KTL) Un-Biased 2.25E-01 2.25E-01 2.25E-01 2.25E-01 2.26E-01 Ps90%/90% (-KTL) Un-Biased 2.15E-01 2.14E-01 2.15E-01 2.16E-01 2.15E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 154 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.72. Plot of Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 155 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.72. Raw data for Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low3 2 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=10mA Device 0 10 20 30 50 284 2.24E-01 2.24E-01 2.23E-01 2.23E-01 2.24E-01 303 2.22E-01 2.21E-01 2.21E-01 2.22E-01 2.23E-01 314 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.20E-01 331 2.25E-01 2.24E-01 2.25E-01 2.25E-01 2.25E-01 368 2.23E-01 2.22E-01 2.23E-01 2.23E-01 2.23E-01 404 2.21E-01 2.20E-01 2.21E-01 2.21E-01 2.21E-01 445 2.24E-01 2.23E-01 2.24E-01 2.24E-01 2.25E-01 474 2.23E-01 2.22E-01 2.23E-01 2.23E-01 2.24E-01 500 2.24E-01 2.23E-01 2.23E-01 2.24E-01 2.24E-01 518 2.24E-01 2.24E-01 2.24E-01 2.25E-01 2.25E-01 524 2.25E-01 2.24E-01 2.25E-01 2.25E-01 2.26E-01 558 2.21E-01 2.20E-01 2.21E-01 2.20E-01 2.21E-01 Biased Statistics Average Biased 2.22E-01 2.22E-01 2.22E-01 2.22E-01 2.23E-01 Std Dev Biased 2.07E-03 2.38E-03 2.21E-03 2.08E-03 2.05E-03 Ps90%/90% (+KTL) Biased 2.28E-01 2.29E-01 2.28E-01 2.28E-01 2.29E-01 Ps90%/90% (-KTL) Biased 2.17E-01 2.16E-01 2.16E-01 2.17E-01 2.17E-01 Un-Biased Statistics Average Un-Biased 2.23E-01 2.23E-01 2.23E-01 2.23E-01 2.24E-01 Std Dev Un-Biased 1.36E-03 1.43E-03 1.21E-03 1.43E-03 1.45E-03 Ps90%/90% (+KTL) Un-Biased 2.27E-01 2.27E-01 2.26E-01 2.27E-01 2.28E-01 Ps90%/90% (-KTL) Un-Biased 2.19E-01 2.19E-01 2.20E-01 2.19E-01 2.20E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 156 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.73. Plot of Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 157 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.73. Raw data for Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low3 3 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=10mA Device 0 10 20 30 50 284 2.21E-01 2.21E-01 2.21E-01 2.20E-01 2.21E-01 303 2.19E-01 2.19E-01 2.19E-01 2.20E-01 2.20E-01 314 2.17E-01 2.17E-01 2.17E-01 2.17E-01 2.18E-01 331 2.22E-01 2.21E-01 2.22E-01 2.22E-01 2.22E-01 368 2.20E-01 2.20E-01 2.21E-01 2.21E-01 2.21E-01 404 2.19E-01 2.19E-01 2.19E-01 2.19E-01 2.20E-01 445 2.21E-01 2.20E-01 2.21E-01 2.21E-01 2.21E-01 474 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.21E-01 500 2.21E-01 2.21E-01 2.21E-01 2.22E-01 2.22E-01 518 2.22E-01 2.21E-01 2.22E-01 2.22E-01 2.22E-01 524 2.23E-01 2.22E-01 2.23E-01 2.22E-01 2.23E-01 558 2.18E-01 2.17E-01 2.18E-01 2.18E-01 2.18E-01 Biased Statistics Average Biased 2.20E-01 2.20E-01 2.20E-01 2.20E-01 2.21E-01 Std Dev Biased 1.79E-03 2.00E-03 1.75E-03 1.79E-03 1.65E-03 Ps90%/90% (+KTL) Biased 2.25E-01 2.25E-01 2.25E-01 2.25E-01 2.25E-01 Ps90%/90% (-KTL) Biased 2.15E-01 2.14E-01 2.15E-01 2.15E-01 2.16E-01 Un-Biased Statistics Average Un-Biased 2.21E-01 2.20E-01 2.20E-01 2.21E-01 2.21E-01 Std Dev Un-Biased 1.13E-03 1.09E-03 1.15E-03 1.20E-03 1.05E-03 Ps90%/90% (+KTL) Un-Biased 2.24E-01 2.23E-01 2.24E-01 2.24E-01 2.24E-01 Ps90%/90% (-KTL) Un-Biased 2.17E-01 2.17E-01 2.17E-01 2.18E-01 2.18E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 158 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.74. Plot of Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 159 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.74. Raw data for Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low3 4 15V (V) Total Dose (krad(Si)) @ VS=+/-15V IL=10mA Device 0 10 20 30 50 284 2.25E-01 2.26E-01 2.25E-01 2.25E-01 2.26E-01 303 2.23E-01 2.23E-01 2.23E-01 2.23E-01 2.24E-01 314 2.24E-01 2.24E-01 2.25E-01 2.24E-01 2.25E-01 331 2.24E-01 2.24E-01 2.25E-01 2.25E-01 2.25E-01 368 2.20E-01 2.19E-01 2.20E-01 2.20E-01 2.20E-01 404 2.20E-01 2.19E-01 2.20E-01 2.20E-01 2.20E-01 445 2.22E-01 2.21E-01 2.22E-01 2.22E-01 2.23E-01 474 2.24E-01 2.23E-01 2.23E-01 2.24E-01 2.24E-01 500 2.25E-01 2.24E-01 2.24E-01 2.24E-01 2.25E-01 518 2.24E-01 2.24E-01 2.24E-01 2.25E-01 2.25E-01 524 2.25E-01 2.24E-01 2.25E-01 2.25E-01 2.25E-01 558 2.22E-01 2.21E-01 2.22E-01 2.22E-01 2.22E-01 Biased Statistics Average Biased 2.23E-01 2.23E-01 2.23E-01 2.23E-01 2.24E-01 Std Dev Biased 1.94E-03 2.57E-03 2.11E-03 2.16E-03 2.16E-03 Ps90%/90% (+KTL) Biased 2.29E-01 2.30E-01 2.29E-01 2.29E-01 2.30E-01 Ps90%/90% (-KTL) Biased 2.18E-01 2.16E-01 2.18E-01 2.17E-01 2.18E-01 Un-Biased Statistics Average Un-Biased 2.23E-01 2.22E-01 2.23E-01 2.23E-01 2.23E-01 Std Dev Un-Biased 1.95E-03 2.12E-03 1.92E-03 1.91E-03 1.89E-03 Ps90%/90% (+KTL) Un-Biased 2.28E-01 2.28E-01 2.28E-01 2.28E-01 2.29E-01 Ps90%/90% (-KTL) Un-Biased 2.18E-01 2.17E-01 2.17E-01 2.18E-01 2.18E-01 Specification MAX 5.00E-01 5.00E-01 5.00E-01 5.00E-01 5.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 160 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ 6.00E+03 5.00E+03 4.00E+03 3.00E+03 2.00E+03 1.00E+03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.75. Plot of Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 161 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.75. Raw data for Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 3.54E+03 3.96E+03 5.50E+03 3.88E+03 3.86E+03 5.75E+03 5.41E+03 3.43E+03 6.17E+03 3.59E+03 3.91E+03 3.86E+03 Total 10 3.50E+03 3.83E+03 5.39E+03 3.76E+03 3.37E+03 5.57E+03 6.56E+03 3.37E+03 5.90E+03 3.54E+03 3.93E+03 3.01E+03 Dose (krad(Si)) 20 30 3.46E+03 3.41E+03 3.72E+03 3.79E+03 5.09E+03 5.01E+03 3.80E+03 3.74E+03 3.50E+03 3.73E+03 5.60E+03 5.83E+03 4.72E+03 5.35E+03 3.34E+03 3.31E+03 5.88E+03 5.73E+03 3.62E+03 3.57E+03 3.98E+03 3.94E+03 3.15E+03 3.01E+03 50 3.35E+03 3.77E+03 5.05E+03 3.75E+03 3.37E+03 5.25E+03 5.05E+03 3.38E+03 5.93E+03 3.50E+03 3.91E+03 3.85E+03 4.15E+03 7.72E+02 6.26E+03 2.03E+03 3.97E+03 8.14E+02 6.20E+03 1.74E+03 3.91E+03 6.72E+02 5.75E+03 2.07E+03 3.94E+03 6.20E+02 5.64E+03 2.24E+03 3.86E+03 6.94E+02 5.76E+03 1.95E+03 4.87E+03 1.27E+03 8.36E+03 1.37E+03 1.00E+03 PASS 4.99E+03 1.44E+03 8.95E+03 1.03E+03 5.00E+02 PASS 4.63E+03 1.14E+03 7.77E+03 1.50E+03 5.00E+02 PASS 4.76E+03 1.22E+03 8.10E+03 1.41E+03 5.00E+02 PASS 4.62E+03 1.13E+03 7.72E+03 1.52E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 162 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ 7.00E+03 6.00E+03 5.00E+03 4.00E+03 3.00E+03 2.00E+03 1.00E+03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.76. Plot of Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 163 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.76. Raw data for Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 6.63E+03 4.02E+03 6.55E+03 6.79E+03 6.64E+03 4.14E+03 6.66E+03 6.18E+03 4.10E+03 5.71E+03 3.77E+03 5.52E+03 Total 10 6.41E+03 3.93E+03 5.95E+03 6.21E+03 6.31E+03 3.97E+03 6.15E+03 6.06E+03 3.96E+03 5.71E+03 3.82E+03 5.46E+03 Dose (krad(Si)) 20 30 5.98E+03 6.13E+03 3.88E+03 3.90E+03 6.26E+03 5.88E+03 6.07E+03 5.94E+03 6.30E+03 5.78E+03 4.18E+03 3.97E+03 6.52E+03 5.97E+03 5.99E+03 5.92E+03 3.96E+03 4.16E+03 5.63E+03 5.92E+03 3.75E+03 3.85E+03 5.31E+03 5.41E+03 50 6.11E+03 3.72E+03 6.11E+03 5.95E+03 5.67E+03 4.09E+03 5.71E+03 5.70E+03 3.91E+03 5.40E+03 3.91E+03 5.31E+03 6.13E+03 1.18E+03 9.36E+03 2.89E+03 5.76E+03 1.04E+03 8.61E+03 2.91E+03 5.70E+03 1.03E+03 8.51E+03 2.88E+03 5.53E+03 9.16E+02 8.04E+03 3.01E+03 5.51E+03 1.02E+03 8.30E+03 2.73E+03 5.36E+03 1.18E+03 8.59E+03 2.13E+03 1.00E+03 PASS 5.17E+03 1.11E+03 8.22E+03 2.12E+03 5.00E+02 PASS 5.25E+03 1.13E+03 8.35E+03 2.16E+03 5.00E+02 PASS 5.19E+03 1.03E+03 8.00E+03 2.37E+03 5.00E+02 PASS 4.96E+03 8.91E+02 7.41E+03 2.52E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 164 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ 1.50E+04 1.00E+04 5.00E+03 0.00E+00 -5.00E+03 -1.00E+04 -1.50E+04 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.77. Plot of Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 165 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.77. Raw data for Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 2.17E+04 6.28E+03 6.66E+03 6.58E+03 4.05E+03 6.31E+03 6.71E+03 4.08E+03 3.89E+03 3.72E+03 3.82E+03 6.31E+03 Total 10 3.95E+03 5.90E+03 6.61E+03 6.43E+03 3.88E+03 6.12E+03 6.40E+03 4.18E+03 3.88E+03 3.86E+03 3.74E+03 6.61E+03 Dose (krad(Si)) 20 30 1.49E+04 6.12E+03 5.76E+03 5.95E+03 6.32E+03 6.06E+03 6.56E+03 6.00E+03 3.90E+03 3.72E+03 6.11E+03 5.89E+03 6.71E+03 6.34E+03 3.90E+03 4.04E+03 3.80E+03 3.83E+03 3.75E+03 3.57E+03 3.77E+03 3.89E+03 6.32E+03 6.15E+03 50 5.92E+03 5.59E+03 6.08E+03 5.68E+03 3.67E+03 5.68E+03 6.23E+03 4.08E+03 3.68E+03 3.54E+03 3.96E+03 6.69E+03 9.05E+03 7.14E+03 2.86E+04 -1.05E+04 5.35E+03 1.34E+03 9.03E+03 1.68E+03 7.49E+03 4.27E+03 1.92E+04 -4.22E+03 5.57E+03 1.03E+03 8.41E+03 2.74E+03 5.39E+03 9.79E+02 8.07E+03 2.70E+03 4.94E+03 1.44E+03 8.89E+03 9.88E+02 1.00E+03 PASS 4.89E+03 1.26E+03 8.35E+03 1.42E+03 5.00E+02 PASS 4.85E+03 1.44E+03 8.79E+03 9.14E+02 5.00E+02 PASS 4.73E+03 1.28E+03 8.25E+03 1.22E+03 5.00E+02 PASS 4.64E+03 1.23E+03 8.01E+03 1.27E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 166 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ 6.00E+03 5.00E+03 4.00E+03 3.00E+03 2.00E+03 1.00E+03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.78. Plot of Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 167 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.78. Raw data for Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 3.61E+03 3.81E+03 4.03E+03 3.30E+03 3.81E+03 3.47E+03 5.74E+03 3.53E+03 7.07E+03 4.24E+03 4.36E+03 4.12E+03 Total 10 3.52E+03 3.77E+03 3.93E+03 3.26E+03 3.80E+03 3.57E+03 5.64E+03 3.51E+03 6.77E+03 4.14E+03 4.37E+03 4.09E+03 Dose (krad(Si)) 20 30 3.24E+03 3.41E+03 3.66E+03 3.75E+03 3.94E+03 3.93E+03 3.23E+03 3.21E+03 3.53E+03 3.59E+03 3.50E+03 3.29E+03 5.67E+03 5.20E+03 3.53E+03 3.43E+03 6.82E+03 6.85E+03 4.10E+03 4.23E+03 4.45E+03 4.45E+03 3.98E+03 4.18E+03 50 3.50E+03 3.63E+03 3.71E+03 3.19E+03 3.56E+03 3.38E+03 5.40E+03 3.43E+03 5.91E+03 4.24E+03 4.37E+03 3.95E+03 3.71E+03 2.73E+02 4.46E+03 2.96E+03 3.65E+03 2.67E+02 4.39E+03 2.92E+03 3.52E+03 3.00E+02 4.34E+03 2.70E+03 3.58E+03 2.84E+02 4.36E+03 2.80E+03 3.52E+03 1.99E+02 4.06E+03 2.97E+03 4.81E+03 1.56E+03 9.08E+03 5.35E+02 1.00E+03 PASS 4.72E+03 1.43E+03 8.64E+03 8.08E+02 5.00E+02 PASS 4.72E+03 1.47E+03 8.75E+03 7.03E+02 5.00E+02 PASS 4.60E+03 1.47E+03 8.64E+03 5.62E+02 5.00E+02 PASS 4.47E+03 1.15E+03 7.62E+03 1.32E+03 5.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 168 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.79. Plot of Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 169 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.79. Raw data for Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 9.70E+02 1.06E+03 2.33E+03 1.02E+03 9.70E+02 2.21E+03 2.43E+03 9.28E+02 2.36E+03 1.01E+03 1.03E+03 1.01E+03 Total 10 9.46E+02 1.04E+03 2.23E+03 9.97E+02 9.46E+02 2.17E+03 2.38E+03 9.08E+02 2.34E+03 9.87E+02 1.04E+03 9.57E+02 Dose (krad(Si)) 20 30 9.38E+02 9.29E+02 1.04E+03 1.03E+03 2.22E+03 2.15E+03 9.85E+02 9.68E+02 9.41E+02 9.16E+02 2.11E+03 2.13E+03 2.36E+03 2.37E+03 9.05E+02 9.10E+02 2.33E+03 2.23E+03 9.75E+02 9.84E+02 1.04E+03 1.03E+03 9.61E+02 9.79E+02 50 9.22E+02 9.99E+02 2.07E+03 9.85E+02 9.34E+02 2.05E+03 2.23E+03 8.89E+02 2.19E+03 9.80E+02 1.03E+03 9.40E+02 1.27E+03 5.96E+02 2.90E+03 -3.64E+02 1.23E+03 5.61E+02 2.77E+03 -3.07E+02 1.23E+03 5.59E+02 2.76E+03 -3.08E+02 1.20E+03 5.32E+02 2.66E+03 -2.61E+02 1.18E+03 4.96E+02 2.54E+03 -1.79E+02 1.79E+03 7.52E+02 3.85E+03 -2.78E+02 5.00E+02 PASS 1.76E+03 7.44E+02 3.80E+03 -2.82E+02 2.50E+02 PASS 1.74E+03 7.34E+02 3.75E+03 -2.76E+02 2.50E+02 PASS 1.72E+03 7.15E+02 3.68E+03 -2.36E+02 2.50E+02 PASS 1.67E+03 6.74E+02 3.52E+03 -1.79E+02 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 170 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.80. Plot of Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 171 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.80. Raw data for Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 2.34E+03 1.05E+03 2.30E+03 2.36E+03 2.31E+03 1.04E+03 2.22E+03 2.26E+03 1.03E+03 2.11E+03 9.28E+02 1.99E+03 Total 10 2.23E+03 1.01E+03 2.18E+03 2.10E+03 2.13E+03 1.05E+03 2.17E+03 2.21E+03 1.02E+03 2.09E+03 9.23E+02 2.05E+03 Dose (krad(Si)) 20 30 2.18E+03 2.14E+03 1.01E+03 1.01E+03 2.12E+03 2.08E+03 2.16E+03 2.02E+03 2.15E+03 1.97E+03 1.02E+03 1.01E+03 2.17E+03 2.13E+03 2.20E+03 2.14E+03 1.01E+03 1.02E+03 2.06E+03 2.01E+03 9.39E+02 9.45E+02 2.00E+03 2.01E+03 50 2.04E+03 1.00E+03 2.10E+03 2.01E+03 2.06E+03 1.02E+03 2.06E+03 2.15E+03 1.00E+03 2.01E+03 9.41E+02 1.99E+03 2.07E+03 5.71E+02 3.63E+03 5.05E+02 1.93E+03 5.14E+02 3.34E+03 5.20E+02 1.92E+03 5.09E+02 3.32E+03 5.28E+02 1.84E+03 4.70E+02 3.13E+03 5.53E+02 1.84E+03 4.70E+02 3.13E+03 5.52E+02 1.73E+03 6.37E+02 3.48E+03 -1.69E+01 5.00E+02 PASS 1.71E+03 6.14E+02 3.39E+03 2.34E+01 2.50E+02 PASS 1.69E+03 6.20E+02 3.39E+03 -9.10E+00 2.50E+02 PASS 1.66E+03 5.95E+02 3.29E+03 2.92E+01 2.50E+02 PASS 1.65E+03 5.85E+02 3.25E+03 4.44E+01 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 172 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 -1.00E+03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.81. Plot of Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 173 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.81. Raw data for Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 2.40E+03 2.31E+03 2.36E+03 2.54E+03 1.06E+03 2.35E+03 2.48E+03 1.07E+03 1.01E+03 9.82E+02 9.84E+02 2.39E+03 Total 10 2.22E+03 2.22E+03 2.23E+03 2.35E+03 1.03E+03 2.30E+03 2.36E+03 1.06E+03 1.02E+03 9.70E+02 9.99E+02 2.38E+03 Dose (krad(Si)) 20 30 2.22E+03 2.27E+03 2.19E+03 2.13E+03 2.15E+03 2.16E+03 2.31E+03 2.26E+03 1.01E+03 1.01E+03 2.22E+03 2.21E+03 2.43E+03 2.43E+03 1.05E+03 1.07E+03 1.01E+03 1.02E+03 9.67E+02 9.52E+02 9.98E+02 9.92E+02 2.35E+03 2.34E+03 50 2.13E+03 2.13E+03 2.22E+03 2.27E+03 9.95E+02 2.16E+03 2.32E+03 1.04E+03 1.00E+03 9.54E+02 9.99E+02 2.33E+03 2.13E+03 6.08E+02 3.80E+03 4.65E+02 2.01E+03 5.49E+02 3.51E+03 5.03E+02 1.98E+03 5.41E+02 3.46E+03 4.91E+02 1.97E+03 5.38E+02 3.44E+03 4.93E+02 1.95E+03 5.35E+02 3.41E+03 4.79E+02 1.58E+03 7.63E+02 3.67E+03 -5.14E+02 5.00E+02 PASS 1.54E+03 7.19E+02 3.51E+03 -4.29E+02 2.50E+02 PASS 1.53E+03 7.25E+02 3.52E+03 -4.54E+02 2.50E+02 PASS 1.54E+03 7.20E+02 3.51E+03 -4.38E+02 2.50E+02 PASS 1.49E+03 6.83E+02 3.37E+03 -3.79E+02 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 174 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 -1.00E+03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.82. Plot of Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 175 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.82. Raw data for Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 9.33E+02 1.02E+03 1.04E+03 8.96E+02 9.30E+02 8.98E+02 2.03E+03 8.88E+02 2.39E+03 1.05E+03 1.09E+03 1.02E+03 Total 10 9.04E+02 9.93E+02 1.02E+03 8.73E+02 9.11E+02 8.86E+02 2.00E+03 8.78E+02 2.33E+03 1.06E+03 1.10E+03 1.03E+03 Dose (krad(Si)) 20 30 9.09E+02 8.91E+02 9.86E+02 9.77E+02 9.84E+02 1.00E+03 8.71E+02 8.61E+02 9.10E+02 9.06E+02 8.91E+02 8.77E+02 1.96E+03 1.91E+03 8.92E+02 8.76E+02 2.29E+03 2.40E+03 1.02E+03 1.03E+03 1.08E+03 1.09E+03 1.03E+03 1.02E+03 50 8.89E+02 9.47E+02 9.80E+02 8.48E+02 8.85E+02 8.69E+02 1.82E+03 8.70E+02 2.22E+03 1.01E+03 1.09E+03 1.03E+03 9.63E+02 6.13E+01 1.13E+03 7.95E+02 9.40E+02 6.26E+01 1.11E+03 7.68E+02 9.32E+02 5.09E+01 1.07E+03 7.92E+02 9.27E+02 5.90E+01 1.09E+03 7.65E+02 9.10E+02 5.29E+01 1.05E+03 7.65E+02 1.45E+03 7.04E+02 3.38E+03 -4.81E+02 5.00E+02 PASS 1.43E+03 6.83E+02 3.30E+03 -4.44E+02 2.50E+02 PASS 1.41E+03 6.65E+02 3.23E+03 -4.15E+02 2.50E+02 PASS 1.42E+03 6.97E+02 3.33E+03 -4.93E+02 2.50E+02 PASS 1.36E+03 6.25E+02 3.07E+03 -3.53E+02 2.50E+02 PASS An ISO 9001:2008 and DSCC Certified Company 176 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V Specification MIN 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.83. Plot of Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 177 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.83. Raw data for Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.01E+02 1.24E+02 1.14E+02 1.06E+02 1.07E+02 1.04E+02 1.12E+02 1.20E+02 1.06E+02 9.92E+01 1.11E+02 1.01E+02 Total 10 1.01E+02 1.24E+02 1.14E+02 1.05E+02 1.07E+02 1.04E+02 1.12E+02 1.20E+02 1.06E+02 9.91E+01 1.11E+02 1.01E+02 Dose (krad(Si)) 20 30 1.01E+02 1.01E+02 1.24E+02 1.25E+02 1.13E+02 1.13E+02 1.05E+02 1.05E+02 1.06E+02 1.06E+02 1.03E+02 1.03E+02 1.12E+02 1.12E+02 1.19E+02 1.19E+02 1.06E+02 1.06E+02 9.91E+01 9.90E+01 1.11E+02 1.11E+02 1.01E+02 1.01E+02 50 1.01E+02 1.24E+02 1.13E+02 1.05E+02 1.06E+02 1.03E+02 1.11E+02 1.19E+02 1.06E+02 9.90E+01 1.11E+02 1.01E+02 1.10E+02 9.13E+00 1.36E+02 8.55E+01 1.10E+02 9.07E+00 1.35E+02 8.52E+01 1.10E+02 9.17E+00 1.35E+02 8.50E+01 1.10E+02 9.44E+00 1.36E+02 8.42E+01 1.10E+02 9.20E+00 1.35E+02 8.47E+01 1.08E+02 8.06E+00 1.30E+02 8.62E+01 9.00E+01 PASS 1.08E+02 7.97E+00 1.30E+02 8.62E+01 8.60E+01 PASS 1.08E+02 7.80E+00 1.29E+02 8.65E+01 8.60E+01 PASS 1.08E+02 7.75E+00 1.29E+02 8.65E+01 8.60E+01 PASS 1.08E+02 7.64E+00 1.29E+02 8.67E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 178 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V Specification MIN 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.84. Plot of Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 179 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.84. Raw data for Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.04E+02 1.01E+02 1.25E+02 1.08E+02 1.29E+02 1.05E+02 1.04E+02 1.03E+02 1.03E+02 1.02E+02 1.02E+02 1.00E+02 Total 10 1.04E+02 1.01E+02 1.23E+02 1.08E+02 1.26E+02 1.05E+02 1.04E+02 1.03E+02 1.03E+02 1.02E+02 1.02E+02 1.00E+02 Dose (krad(Si)) 20 30 1.04E+02 1.04E+02 1.01E+02 1.01E+02 1.23E+02 1.23E+02 1.08E+02 1.08E+02 1.26E+02 1.25E+02 1.05E+02 1.05E+02 1.04E+02 1.04E+02 1.03E+02 1.03E+02 1.03E+02 1.03E+02 1.02E+02 1.02E+02 1.02E+02 1.02E+02 1.01E+02 1.00E+02 50 1.04E+02 1.01E+02 1.22E+02 1.08E+02 1.24E+02 1.05E+02 1.04E+02 1.03E+02 1.03E+02 1.02E+02 1.02E+02 1.00E+02 1.13E+02 1.27E+01 1.48E+02 7.86E+01 1.12E+02 1.13E+01 1.43E+02 8.14E+01 1.12E+02 1.12E+01 1.43E+02 8.16E+01 1.12E+02 1.12E+01 1.43E+02 8.16E+01 1.12E+02 1.08E+01 1.41E+02 8.23E+01 1.04E+02 1.13E+00 1.07E+02 1.01E+02 9.00E+01 PASS 1.04E+02 1.10E+00 1.07E+02 1.01E+02 8.60E+01 PASS 1.03E+02 1.13E+00 1.06E+02 1.00E+02 8.60E+01 PASS 1.03E+02 1.14E+00 1.06E+02 1.00E+02 8.60E+01 PASS 1.03E+02 1.13E+00 1.06E+02 1.00E+02 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 180 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Specification MIN 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.85. Plot of Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 181 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.85. Raw data for Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.08E+02 1.06E+02 1.16E+02 1.03E+02 1.40E+02 1.24E+02 1.18E+02 1.00E+02 1.11E+02 1.04E+02 1.01E+02 1.08E+02 Total 10 1.08E+02 1.06E+02 1.15E+02 1.02E+02 1.62E+02 1.26E+02 1.17E+02 1.00E+02 1.12E+02 1.03E+02 1.01E+02 1.08E+02 Dose (krad(Si)) 20 30 1.07E+02 1.07E+02 1.06E+02 1.06E+02 1.14E+02 1.14E+02 1.02E+02 1.02E+02 1.43E+02 1.63E+02 1.28E+02 1.27E+02 1.16E+02 1.17E+02 9.99E+01 1.00E+02 1.12E+02 1.12E+02 1.03E+02 1.03E+02 1.01E+02 1.01E+02 1.08E+02 1.08E+02 50 1.08E+02 1.06E+02 1.14E+02 1.02E+02 1.53E+02 1.27E+02 1.16E+02 1.00E+02 1.12E+02 1.03E+02 1.01E+02 1.08E+02 1.15E+02 1.51E+01 1.56E+02 7.32E+01 1.19E+02 2.49E+01 1.87E+02 5.03E+01 1.14E+02 1.65E+01 1.60E+02 6.92E+01 1.19E+02 2.52E+01 1.88E+02 4.96E+01 1.16E+02 2.06E+01 1.73E+02 5.99E+01 1.12E+02 1.01E+01 1.39E+02 8.39E+01 9.00E+01 PASS 1.12E+02 1.05E+01 1.40E+02 8.29E+01 8.60E+01 PASS 1.12E+02 1.11E+01 1.42E+02 8.14E+01 8.60E+01 PASS 1.12E+02 1.06E+01 1.41E+02 8.26E+01 8.60E+01 PASS 1.12E+02 1.08E+01 1.41E+02 8.21E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 182 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V Specification MIN 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.86. Plot of Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 183 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.86. Raw data for Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.05E+02 9.89E+01 1.02E+02 1.29E+02 1.07E+02 9.81E+01 1.23E+02 1.04E+02 1.08E+02 1.08E+02 1.10E+02 1.05E+02 Total 10 1.05E+02 9.91E+01 1.02E+02 1.31E+02 1.07E+02 9.80E+01 1.24E+02 1.04E+02 1.09E+02 1.08E+02 1.10E+02 1.05E+02 Dose (krad(Si)) 20 30 1.05E+02 1.05E+02 9.91E+01 9.91E+01 1.02E+02 1.02E+02 1.31E+02 1.32E+02 1.07E+02 1.07E+02 9.80E+01 9.80E+01 1.24E+02 1.24E+02 1.04E+02 1.04E+02 1.08E+02 1.08E+02 1.08E+02 1.08E+02 1.09E+02 1.10E+02 1.05E+02 1.05E+02 50 1.05E+02 9.91E+01 1.02E+02 1.32E+02 1.07E+02 9.79E+01 1.25E+02 1.04E+02 1.08E+02 1.08E+02 1.09E+02 1.05E+02 1.08E+02 1.22E+01 1.42E+02 7.49E+01 1.09E+02 1.30E+01 1.44E+02 7.31E+01 1.08E+02 1.27E+01 1.43E+02 7.38E+01 1.09E+02 1.33E+01 1.45E+02 7.24E+01 1.09E+02 1.31E+01 1.45E+02 7.28E+01 1.08E+02 9.10E+00 1.33E+02 8.35E+01 9.00E+01 PASS 1.09E+02 9.43E+00 1.34E+02 8.27E+01 8.60E+01 PASS 1.09E+02 9.66E+00 1.35E+02 8.21E+01 8.60E+01 PASS 1.09E+02 9.71E+00 1.35E+02 8.19E+01 8.60E+01 PASS 1.09E+02 1.01E+01 1.36E+02 8.10E+01 8.60E+01 PASS An ISO 9001:2008 and DSCC Certified Company 184 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Specification MIN CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.87. Plot of CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 185 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.87. Raw data for CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.11E+02 9.94E+01 1.04E+02 1.05E+02 1.42E+02 1.04E+02 1.10E+02 1.06E+02 1.19E+02 1.03E+02 1.04E+02 1.12E+02 Total 10 1.10E+02 9.96E+01 1.04E+02 1.05E+02 1.48E+02 1.05E+02 1.10E+02 1.06E+02 1.19E+02 1.03E+02 1.04E+02 1.12E+02 Dose (krad(Si)) 20 30 1.10E+02 1.10E+02 9.96E+01 9.95E+01 1.04E+02 1.04E+02 1.05E+02 1.05E+02 1.37E+02 1.32E+02 1.05E+02 1.05E+02 1.10E+02 1.10E+02 1.06E+02 1.06E+02 1.18E+02 1.18E+02 1.03E+02 1.03E+02 1.04E+02 1.04E+02 1.11E+02 1.12E+02 50 1.10E+02 9.96E+01 1.04E+02 1.05E+02 1.30E+02 1.05E+02 1.10E+02 1.06E+02 1.18E+02 1.03E+02 1.04E+02 1.11E+02 1.12E+02 1.73E+01 1.60E+02 6.48E+01 1.13E+02 1.98E+01 1.67E+02 5.90E+01 1.11E+02 1.50E+01 1.52E+02 7.01E+01 1.10E+02 1.29E+01 1.45E+02 7.48E+01 1.10E+02 1.18E+01 1.42E+02 7.73E+01 1.08E+02 6.59E+00 1.27E+02 9.04E+01 8.40E+01 PASS 1.08E+02 6.38E+00 1.26E+02 9.09E+01 8.30E+01 PASS 1.08E+02 6.23E+00 1.25E+02 9.12E+01 8.30E+01 PASS 1.08E+02 6.22E+00 1.25E+02 9.12E+01 8.30E+01 PASS 1.08E+02 6.07E+00 1.25E+02 9.16E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 186 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Specification MIN CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.88. Plot of CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 187 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.88. Raw data for CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.12E+02 1.09E+02 1.20E+02 1.09E+02 1.27E+02 1.04E+02 1.06E+02 1.10E+02 1.00E+02 1.19E+02 1.19E+02 1.05E+02 Total 10 1.13E+02 1.09E+02 1.19E+02 1.08E+02 1.26E+02 1.04E+02 1.07E+02 1.10E+02 1.00E+02 1.20E+02 1.18E+02 1.06E+02 Dose (krad(Si)) 20 30 1.14E+02 1.13E+02 1.10E+02 1.10E+02 1.18E+02 1.18E+02 1.09E+02 1.09E+02 1.27E+02 1.25E+02 1.04E+02 1.04E+02 1.07E+02 1.06E+02 1.10E+02 1.10E+02 1.00E+02 1.00E+02 1.19E+02 1.18E+02 1.19E+02 1.20E+02 1.05E+02 1.05E+02 50 1.12E+02 1.10E+02 1.18E+02 1.09E+02 1.25E+02 1.04E+02 1.06E+02 1.10E+02 1.00E+02 1.18E+02 1.20E+02 1.05E+02 1.15E+02 7.79E+00 1.37E+02 9.41E+01 1.15E+02 7.34E+00 1.35E+02 9.50E+01 1.16E+02 7.31E+00 1.36E+02 9.56E+01 1.15E+02 6.74E+00 1.34E+02 9.66E+01 1.15E+02 6.61E+00 1.33E+02 9.68E+01 1.08E+02 7.14E+00 1.28E+02 8.84E+01 8.40E+01 PASS 1.08E+02 7.45E+00 1.29E+02 8.77E+01 8.30E+01 PASS 1.08E+02 6.91E+00 1.27E+02 8.89E+01 8.30E+01 PASS 1.08E+02 6.75E+00 1.26E+02 8.92E+01 8.30E+01 PASS 1.08E+02 6.67E+00 1.26E+02 8.94E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 188 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.89. Plot of Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 189 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.89. Raw data for Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.14E+02 1.18E+02 1.05E+02 1.12E+02 1.12E+02 1.24E+02 1.04E+02 1.07E+02 1.13E+02 1.18E+02 1.18E+02 1.15E+02 Total 10 1.14E+02 1.18E+02 1.05E+02 1.12E+02 1.12E+02 1.24E+02 1.04E+02 1.07E+02 1.13E+02 1.18E+02 1.19E+02 1.15E+02 Dose (krad(Si)) 20 30 1.14E+02 1.14E+02 1.19E+02 1.19E+02 1.05E+02 1.05E+02 1.12E+02 1.12E+02 1.12E+02 1.12E+02 1.24E+02 1.24E+02 1.04E+02 1.04E+02 1.07E+02 1.07E+02 1.13E+02 1.13E+02 1.18E+02 1.18E+02 1.18E+02 1.19E+02 1.15E+02 1.15E+02 50 1.14E+02 1.19E+02 1.05E+02 1.12E+02 1.12E+02 1.24E+02 1.04E+02 1.07E+02 1.13E+02 1.18E+02 1.19E+02 1.15E+02 1.12E+02 4.69E+00 1.25E+02 9.94E+01 1.12E+02 4.67E+00 1.25E+02 9.95E+01 1.12E+02 4.74E+00 1.25E+02 9.94E+01 1.12E+02 4.76E+00 1.25E+02 9.93E+01 1.12E+02 4.80E+00 1.26E+02 9.93E+01 1.13E+02 8.01E+00 1.35E+02 9.12E+01 9.00E+01 PASS 1.13E+02 8.12E+00 1.35E+02 9.09E+01 9.00E+01 PASS 1.13E+02 8.06E+00 1.35E+02 9.11E+01 9.00E+01 PASS 1.13E+02 8.05E+00 1.35E+02 9.11E+01 9.00E+01 PASS 1.13E+02 8.16E+00 1.36E+02 9.08E+01 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 190 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.90. Plot of Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 191 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.90. Raw data for Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.33E+02 1.29E+02 1.08E+02 1.14E+02 1.16E+02 1.16E+02 1.17E+02 1.14E+02 1.13E+02 1.15E+02 1.36E+02 1.11E+02 Total 10 1.33E+02 1.29E+02 1.08E+02 1.14E+02 1.16E+02 1.16E+02 1.17E+02 1.14E+02 1.13E+02 1.15E+02 1.36E+02 1.11E+02 Dose (krad(Si)) 20 30 1.33E+02 1.34E+02 1.29E+02 1.29E+02 1.08E+02 1.08E+02 1.14E+02 1.14E+02 1.16E+02 1.16E+02 1.17E+02 1.16E+02 1.17E+02 1.17E+02 1.14E+02 1.15E+02 1.13E+02 1.13E+02 1.15E+02 1.15E+02 1.36E+02 1.37E+02 1.11E+02 1.11E+02 50 1.34E+02 1.29E+02 1.08E+02 1.14E+02 1.16E+02 1.16E+02 1.17E+02 1.14E+02 1.13E+02 1.15E+02 1.37E+02 1.11E+02 1.20E+02 1.05E+01 1.49E+02 9.11E+01 1.20E+02 1.04E+01 1.48E+02 9.14E+01 1.20E+02 1.06E+01 1.49E+02 9.11E+01 1.20E+02 1.08E+01 1.50E+02 9.07E+01 1.20E+02 1.08E+01 1.50E+02 9.05E+01 1.15E+02 1.69E+00 1.20E+02 1.11E+02 9.00E+01 PASS 1.15E+02 1.73E+00 1.20E+02 1.11E+02 9.00E+01 PASS 1.15E+02 1.76E+00 1.20E+02 1.10E+02 9.00E+01 PASS 1.15E+02 1.73E+00 1.20E+02 1.11E+02 9.00E+01 PASS 1.15E+02 1.74E+00 1.20E+02 1.10E+02 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 192 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.91. Plot of Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 193 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.91. Raw data for Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.17E+02 1.16E+02 1.14E+02 1.11E+02 1.09E+02 1.15E+02 1.11E+02 1.10E+02 1.32E+02 1.22E+02 1.09E+02 1.17E+02 Total 10 1.17E+02 1.16E+02 1.14E+02 1.11E+02 1.10E+02 1.15E+02 1.11E+02 1.10E+02 1.32E+02 1.22E+02 1.09E+02 1.17E+02 Dose (krad(Si)) 20 30 1.18E+02 1.18E+02 1.16E+02 1.16E+02 1.14E+02 1.14E+02 1.11E+02 1.11E+02 1.10E+02 1.10E+02 1.15E+02 1.15E+02 1.11E+02 1.11E+02 1.10E+02 1.10E+02 1.31E+02 1.31E+02 1.22E+02 1.22E+02 1.09E+02 1.09E+02 1.17E+02 1.17E+02 50 1.18E+02 1.16E+02 1.14E+02 1.11E+02 1.10E+02 1.15E+02 1.11E+02 1.10E+02 1.31E+02 1.22E+02 1.09E+02 1.17E+02 1.13E+02 3.13E+00 1.22E+02 1.05E+02 1.14E+02 3.20E+00 1.22E+02 1.05E+02 1.14E+02 3.33E+00 1.23E+02 1.04E+02 1.14E+02 3.33E+00 1.23E+02 1.04E+02 1.14E+02 3.31E+00 1.23E+02 1.05E+02 1.18E+02 9.16E+00 1.43E+02 9.26E+01 9.00E+01 PASS 1.18E+02 9.11E+00 1.43E+02 9.28E+01 9.00E+01 PASS 1.18E+02 8.99E+00 1.42E+02 9.30E+01 9.00E+01 PASS 1.18E+02 9.03E+00 1.42E+02 9.29E+01 9.00E+01 PASS 1.18E+02 8.78E+00 1.42E+02 9.35E+01 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 194 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.92. Plot of Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 195 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.92. Raw data for Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.16E+02 1.18E+02 1.39E+02 1.09E+02 1.21E+02 1.13E+02 1.09E+02 1.21E+02 1.12E+02 1.11E+02 1.06E+02 1.12E+02 Total 10 1.16E+02 1.18E+02 1.42E+02 1.09E+02 1.21E+02 1.13E+02 1.09E+02 1.21E+02 1.12E+02 1.11E+02 1.06E+02 1.12E+02 Dose (krad(Si)) 20 30 1.16E+02 1.16E+02 1.18E+02 1.18E+02 1.43E+02 1.44E+02 1.09E+02 1.09E+02 1.21E+02 1.21E+02 1.13E+02 1.14E+02 1.09E+02 1.09E+02 1.21E+02 1.21E+02 1.12E+02 1.12E+02 1.11E+02 1.11E+02 1.06E+02 1.06E+02 1.12E+02 1.12E+02 50 1.16E+02 1.18E+02 1.46E+02 1.09E+02 1.22E+02 1.14E+02 1.09E+02 1.21E+02 1.12E+02 1.11E+02 1.06E+02 1.12E+02 1.20E+02 1.13E+01 1.51E+02 8.95E+01 1.21E+02 1.24E+01 1.55E+02 8.71E+01 1.21E+02 1.28E+01 1.56E+02 8.61E+01 1.21E+02 1.32E+01 1.58E+02 8.50E+01 1.22E+02 1.42E+01 1.61E+02 8.31E+01 1.13E+02 4.84E+00 1.26E+02 9.99E+01 9.00E+01 PASS 1.13E+02 4.79E+00 1.26E+02 1.00E+02 9.00E+01 PASS 1.13E+02 4.70E+00 1.26E+02 1.00E+02 9.00E+01 PASS 1.13E+02 4.75E+00 1.26E+02 1.00E+02 9.00E+01 PASS 1.13E+02 4.73E+00 1.26E+02 1.00E+02 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 196 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.93. Plot of PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 197 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.93. Raw data for PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V Device 284 303 314 331 368 404 445 474 500 518 524 558 0 1.09E+02 1.12E+02 1.06E+02 1.20E+02 1.09E+02 1.11E+02 1.00E+02 1.09E+02 1.28E+02 1.16E+02 1.08E+02 1.23E+02 Biased Statistics Average Biased 1.11E+02 Std Dev Biased 5.59E+00 Ps90%/90% (+KTL) Biased 1.27E+02 Ps90%/90% (-KTL) Biased 9.59E+01 Un-Biased Statistics Average Un-Biased 1.13E+02 Std Dev Un-Biased 1.03E+01 Ps90%/90% (+KTL) Un-Biased 1.41E+02 Ps90%/90% (-KTL) Un-Biased 8.44E+01 Specification MIN 8.30E+01 Status PASS Total 10 1.09E+02 1.12E+02 1.06E+02 1.20E+02 1.10E+02 1.11E+02 1.00E+02 1.09E+02 1.29E+02 1.16E+02 1.08E+02 1.24E+02 Dose (krad(Si)) 20 30 1.09E+02 1.09E+02 1.12E+02 1.12E+02 1.06E+02 1.06E+02 1.20E+02 1.20E+02 1.10E+02 1.10E+02 1.11E+02 1.11E+02 1.00E+02 1.00E+02 1.09E+02 1.09E+02 1.29E+02 1.28E+02 1.16E+02 1.16E+02 1.08E+02 1.08E+02 1.24E+02 1.23E+02 50 1.09E+02 1.12E+02 1.06E+02 1.20E+02 1.10E+02 1.11E+02 1.00E+02 1.09E+02 1.29E+02 1.16E+02 1.08E+02 1.23E+02 1.11E+02 5.55E+00 1.26E+02 9.60E+01 1.11E+02 5.53E+00 1.26E+02 9.61E+01 1.11E+02 5.46E+00 1.26E+02 9.62E+01 1.11E+02 5.48E+00 1.26E+02 9.63E+01 1.13E+02 1.04E+01 1.41E+02 8.42E+01 8.30E+01 PASS 1.13E+02 1.05E+01 1.42E+02 8.41E+01 8.30E+01 PASS 1.13E+02 1.02E+01 1.41E+02 8.47E+01 8.30E+01 PASS 1.13E+02 1.05E+01 1.42E+02 8.41E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 198 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.94. Plot of PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 199 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.94. Raw data for PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V Device 284 303 314 331 368 404 445 474 500 518 524 558 0 1.18E+02 1.14E+02 1.15E+02 1.22E+02 1.15E+02 1.30E+02 1.07E+02 1.17E+02 1.14E+02 1.21E+02 1.09E+02 1.08E+02 Biased Statistics Average Biased 1.17E+02 Std Dev Biased 3.19E+00 Ps90%/90% (+KTL) Biased 1.26E+02 Ps90%/90% (-KTL) Biased 1.08E+02 Un-Biased Statistics Average Un-Biased 1.18E+02 Std Dev Un-Biased 8.47E+00 Ps90%/90% (+KTL) Un-Biased 1.41E+02 Ps90%/90% (-KTL) Un-Biased 9.46E+01 Specification MIN 8.30E+01 Status PASS Total 10 1.19E+02 1.14E+02 1.15E+02 1.22E+02 1.15E+02 1.30E+02 1.08E+02 1.17E+02 1.14E+02 1.21E+02 1.09E+02 1.08E+02 Dose (krad(Si)) 20 30 1.19E+02 1.19E+02 1.14E+02 1.14E+02 1.15E+02 1.15E+02 1.22E+02 1.22E+02 1.16E+02 1.16E+02 1.29E+02 1.29E+02 1.08E+02 1.07E+02 1.17E+02 1.17E+02 1.14E+02 1.14E+02 1.21E+02 1.21E+02 1.09E+02 1.09E+02 1.08E+02 1.08E+02 50 1.19E+02 1.14E+02 1.15E+02 1.22E+02 1.16E+02 1.29E+02 1.07E+02 1.17E+02 1.14E+02 1.21E+02 1.09E+02 1.08E+02 1.17E+02 3.37E+00 1.26E+02 1.08E+02 1.17E+02 3.27E+00 1.26E+02 1.08E+02 1.17E+02 3.29E+00 1.26E+02 1.08E+02 1.17E+02 3.40E+00 1.27E+02 1.08E+02 1.18E+02 8.20E+00 1.40E+02 9.53E+01 8.30E+01 PASS 1.18E+02 7.79E+00 1.39E+02 9.61E+01 8.30E+01 PASS 1.18E+02 7.87E+00 1.39E+02 9.59E+01 8.30E+01 PASS 1.18E+02 7.92E+00 1.39E+02 9.59E+01 8.30E+01 PASS An ISO 9001:2008 and DSCC Certified Company 200 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.95. Plot of +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 201 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.95. Raw data for +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status Total 10 -3.58E-02 -3.40E-02 -3.59E-02 -3.41E-02 -3.48E-02 -3.58E-02 -3.71E-02 -3.44E-02 -3.46E-02 -3.49E-02 -3.69E-02 -3.76E-02 0 -3.67E-02 -3.48E-02 -3.68E-02 -3.54E-02 -3.58E-02 -3.63E-02 -3.76E-02 -3.47E-02 -3.49E-02 -3.53E-02 -3.70E-02 -3.77E-02 Dose (krad(Si)) 20 30 -3.53E-02 -3.49E-02 -3.36E-02 -3.34E-02 -3.56E-02 -3.53E-02 -3.44E-02 -3.40E-02 -3.47E-02 -3.43E-02 -3.56E-02 -3.54E-02 -3.68E-02 -3.66E-02 -3.40E-02 -3.39E-02 -3.43E-02 -3.41E-02 -3.47E-02 -3.45E-02 -3.72E-02 -3.71E-02 -3.79E-02 -3.77E-02 50 -3.46E-02 -3.30E-02 -3.49E-02 -3.36E-02 -3.39E-02 -3.50E-02 -3.63E-02 -3.35E-02 -3.38E-02 -3.41E-02 -3.71E-02 -3.78E-02 -3.59E-02 -3.49E-02 -3.47E-02 -3.44E-02 -3.40E-02 8.51E-04 9.11E-04 7.92E-04 7.69E-04 7.70E-04 -3.36E-02 -3.24E-02 -3.25E-02 -3.23E-02 -3.19E-02 -3.82E-02 -3.74E-02 -3.69E-02 -3.65E-02 -3.61E-02 -3.58E-02 1.23E-03 -3.24E-02 -3.91E-02 -1.50E-02 PASS -3.53E-02 1.12E-03 -3.23E-02 -3.84E-02 -1.00E-02 PASS -3.51E-02 1.15E-03 -3.19E-02 -3.82E-02 -1.00E-02 PASS -3.49E-02 1.12E-03 -3.18E-02 -3.80E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 202 -3.46E-02 1.12E-03 -3.15E-02 -3.76E-02 -1.00E-02 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.96. Plot of +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 203 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.96. Raw data for +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status Total 10 -3.69E-02 -3.55E-02 -3.60E-02 -3.39E-02 -3.73E-02 -3.81E-02 -3.58E-02 -3.64E-02 -3.59E-02 -3.54E-02 -3.73E-02 -4.00E-02 0 -3.79E-02 -3.64E-02 -3.68E-02 -3.52E-02 -3.84E-02 -3.87E-02 -3.63E-02 -3.67E-02 -3.62E-02 -3.58E-02 -3.74E-02 -4.02E-02 Dose (krad(Si)) 20 30 -3.65E-02 -3.61E-02 -3.51E-02 -3.49E-02 -3.57E-02 -3.55E-02 -3.42E-02 -3.38E-02 -3.72E-02 -3.68E-02 -3.79E-02 -3.77E-02 -3.55E-02 -3.53E-02 -3.60E-02 -3.58E-02 -3.55E-02 -3.54E-02 -3.52E-02 -3.50E-02 -3.76E-02 -3.74E-02 -4.03E-02 -4.02E-02 50 -3.58E-02 -3.45E-02 -3.50E-02 -3.33E-02 -3.64E-02 -3.74E-02 -3.50E-02 -3.55E-02 -3.50E-02 -3.46E-02 -3.75E-02 -4.03E-02 -3.69E-02 -3.59E-02 -3.57E-02 -3.54E-02 -3.50E-02 1.26E-03 1.35E-03 1.16E-03 1.15E-03 1.18E-03 -3.35E-02 -3.22E-02 -3.25E-02 -3.22E-02 -3.18E-02 -4.04E-02 -3.96E-02 -3.89E-02 -3.86E-02 -3.82E-02 -3.67E-02 1.12E-03 -3.37E-02 -3.98E-02 -1.50E-02 PASS -3.63E-02 1.05E-03 -3.34E-02 -3.92E-02 -1.00E-02 PASS -3.60E-02 1.09E-03 -3.30E-02 -3.90E-02 -1.00E-02 PASS -3.59E-02 1.08E-03 -3.29E-02 -3.88E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 204 -3.55E-02 1.10E-03 -3.25E-02 -3.85E-02 -1.00E-02 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.97. Plot of +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 205 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.97. Raw data for +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status Total 10 -3.72E-02 -3.63E-02 -3.65E-02 -3.41E-02 -3.76E-02 -3.88E-02 -3.64E-02 -3.62E-02 -3.65E-02 -3.59E-02 -3.75E-02 -4.06E-02 0 -3.81E-02 -3.72E-02 -3.74E-02 -3.55E-02 -3.87E-02 -3.94E-02 -3.69E-02 -3.65E-02 -3.69E-02 -3.62E-02 -3.76E-02 -4.07E-02 Dose (krad(Si)) 20 30 -3.67E-02 -3.64E-02 -3.59E-02 -3.56E-02 -3.62E-02 -3.60E-02 -3.44E-02 -3.40E-02 -3.74E-02 -3.71E-02 -3.86E-02 -3.84E-02 -3.60E-02 -3.59E-02 -3.57E-02 -3.56E-02 -3.61E-02 -3.60E-02 -3.57E-02 -3.55E-02 -3.78E-02 -3.76E-02 -4.09E-02 -4.07E-02 50 -3.61E-02 -3.52E-02 -3.55E-02 -3.36E-02 -3.66E-02 -3.81E-02 -3.55E-02 -3.53E-02 -3.56E-02 -3.51E-02 -3.77E-02 -4.08E-02 -3.74E-02 -3.63E-02 -3.61E-02 -3.58E-02 -3.54E-02 1.23E-03 1.35E-03 1.13E-03 1.13E-03 1.15E-03 -3.40E-02 -3.26E-02 -3.30E-02 -3.27E-02 -3.22E-02 -4.07E-02 -4.00E-02 -3.92E-02 -3.89E-02 -3.86E-02 -3.72E-02 1.28E-03 -3.36E-02 -4.07E-02 -1.50E-02 PASS -3.67E-02 1.19E-03 -3.35E-02 -4.00E-02 -1.00E-02 PASS -3.64E-02 1.24E-03 -3.30E-02 -3.98E-02 -1.00E-02 PASS -3.63E-02 1.23E-03 -3.29E-02 -3.96E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 206 -3.59E-02 1.24E-03 -3.25E-02 -3.93E-02 -1.00E-02 PASS TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 -3.50E-02 -4.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.98. Plot of +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 207 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.98. Raw data for +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status Total 10 -3.62E-02 -3.45E-02 -3.60E-02 -3.48E-02 -3.56E-02 -3.64E-02 -3.83E-02 -3.59E-02 -3.50E-02 -3.58E-02 -3.75E-02 -3.87E-02 0 -3.71E-02 -3.53E-02 -3.69E-02 -3.62E-02 -3.67E-02 -3.70E-02 -3.89E-02 -3.62E-02 -3.53E-02 -3.61E-02 -3.76E-02 -3.89E-02 Dose (krad(Si)) 20 30 -3.57E-02 -3.54E-02 -3.41E-02 -3.39E-02 -3.58E-02 -3.55E-02 -3.51E-02 -3.48E-02 -3.55E-02 -3.51E-02 -3.63E-02 -3.60E-02 -3.80E-02 -3.78E-02 -3.55E-02 -3.54E-02 -3.47E-02 -3.45E-02 -3.56E-02 -3.54E-02 -3.78E-02 -3.77E-02 -3.90E-02 -3.89E-02 50 -3.50E-02 -3.35E-02 -3.50E-02 -3.43E-02 -3.47E-02 -3.57E-02 -3.75E-02 -3.50E-02 -3.42E-02 -3.50E-02 -3.77E-02 -3.89E-02 -3.64E-02 -3.54E-02 -3.53E-02 -3.49E-02 -3.45E-02 7.46E-04 7.63E-04 6.95E-04 6.56E-04 6.46E-04 -3.44E-02 -3.33E-02 -3.33E-02 -3.31E-02 -3.27E-02 -3.85E-02 -3.75E-02 -3.72E-02 -3.67E-02 -3.63E-02 -3.67E-02 1.35E-03 -3.30E-02 -4.04E-02 -1.50E-02 PASS -3.63E-02 1.25E-03 -3.29E-02 -3.97E-02 -1.00E-02 PASS -3.60E-02 1.26E-03 -3.25E-02 -3.94E-02 -1.00E-02 PASS -3.58E-02 1.25E-03 -3.24E-02 -3.92E-02 -1.00E-02 PASS An ISO 9001:2008 and DSCC Certified Company 208 -3.55E-02 1.24E-03 -3.21E-02 -3.89E-02 -1.00E-02 PASS TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 7.00E-02 -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.99. Plot of -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 209 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.99. Raw data for -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Short-Circuit Current1 1 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VOUT=0V Device 0 10 20 30 50 284 5.79E-02 5.77E-02 5.78E-02 5.77E-02 5.74E-02 303 5.88E-02 5.88E-02 5.87E-02 5.84E-02 5.82E-02 314 5.80E-02 5.80E-02 5.77E-02 5.76E-02 5.75E-02 331 5.84E-02 5.84E-02 5.80E-02 5.81E-02 5.80E-02 368 5.93E-02 5.96E-02 5.91E-02 5.91E-02 5.90E-02 404 5.85E-02 5.89E-02 5.87E-02 5.86E-02 5.85E-02 445 5.84E-02 5.86E-02 5.86E-02 5.85E-02 5.84E-02 474 5.83E-02 5.82E-02 5.85E-02 5.83E-02 5.81E-02 500 5.82E-02 5.82E-02 5.83E-02 5.81E-02 5.80E-02 518 5.82E-02 5.82E-02 5.80E-02 5.79E-02 5.78E-02 524 5.82E-02 5.84E-02 5.80E-02 5.82E-02 5.81E-02 558 5.88E-02 5.90E-02 5.85E-02 5.88E-02 5.86E-02 Biased Statistics Average Biased 5.85E-02 5.85E-02 5.82E-02 5.82E-02 5.80E-02 Std Dev Biased 5.71E-04 7.56E-04 5.85E-04 6.16E-04 6.56E-04 Ps90%/90% (+KTL) Biased 6.00E-02 6.06E-02 5.99E-02 5.99E-02 5.98E-02 Ps90%/90% (-KTL) Biased 5.69E-02 5.64E-02 5.66E-02 5.65E-02 5.62E-02 Un-Biased Statistics Average Un-Biased 5.83E-02 5.84E-02 5.84E-02 5.83E-02 5.82E-02 Std Dev Un-Biased 1.43E-04 3.23E-04 2.91E-04 2.82E-04 2.66E-04 Ps90%/90% (+KTL) Un-Biased 5.87E-02 5.93E-02 5.92E-02 5.90E-02 5.89E-02 Ps90%/90% (-KTL) Un-Biased 5.79E-02 5.75E-02 5.76E-02 5.75E-02 5.74E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 210 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 7.00E-02 -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.100. Plot of -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 211 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.100. Raw data for -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Short-Circuit Current1 2 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VOUT=0V Device 0 10 20 30 50 284 5.72E-02 5.71E-02 5.72E-02 5.71E-02 5.67E-02 303 5.80E-02 5.80E-02 5.79E-02 5.77E-02 5.75E-02 314 5.75E-02 5.75E-02 5.72E-02 5.72E-02 5.71E-02 331 5.69E-02 5.69E-02 5.65E-02 5.66E-02 5.65E-02 368 5.73E-02 5.76E-02 5.71E-02 5.72E-02 5.71E-02 404 5.73E-02 5.77E-02 5.75E-02 5.74E-02 5.73E-02 445 5.66E-02 5.69E-02 5.69E-02 5.67E-02 5.66E-02 474 5.70E-02 5.69E-02 5.71E-02 5.69E-02 5.68E-02 500 5.71E-02 5.71E-02 5.71E-02 5.70E-02 5.68E-02 518 5.66E-02 5.67E-02 5.65E-02 5.64E-02 5.64E-02 524 5.67E-02 5.68E-02 5.64E-02 5.67E-02 5.66E-02 558 5.74E-02 5.76E-02 5.72E-02 5.74E-02 5.73E-02 Biased Statistics Average Biased 5.74E-02 5.74E-02 5.72E-02 5.71E-02 5.70E-02 Std Dev Biased 4.43E-04 4.19E-04 5.06E-04 3.93E-04 3.77E-04 Ps90%/90% (+KTL) Biased 5.86E-02 5.86E-02 5.86E-02 5.82E-02 5.80E-02 Ps90%/90% (-KTL) Biased 5.62E-02 5.63E-02 5.58E-02 5.61E-02 5.59E-02 Un-Biased Statistics Average Un-Biased 5.69E-02 5.70E-02 5.70E-02 5.69E-02 5.68E-02 Std Dev Un-Biased 3.16E-04 3.84E-04 3.79E-04 3.72E-04 3.59E-04 Ps90%/90% (+KTL) Un-Biased 5.78E-02 5.81E-02 5.81E-02 5.79E-02 5.78E-02 Ps90%/90% (-KTL) Un-Biased 5.61E-02 5.60E-02 5.60E-02 5.59E-02 5.58E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 212 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 7.00E-02 -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.101. Plot of -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 213 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.101. Raw data for -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Short-Circuit Current1 3 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VOUT=0V Device 0 10 20 30 50 284 5.73E-02 5.72E-02 5.73E-02 5.72E-02 5.68E-02 303 5.79E-02 5.79E-02 5.78E-02 5.76E-02 5.74E-02 314 5.76E-02 5.76E-02 5.74E-02 5.73E-02 5.72E-02 331 5.70E-02 5.70E-02 5.66E-02 5.67E-02 5.66E-02 368 5.73E-02 5.76E-02 5.71E-02 5.72E-02 5.70E-02 404 5.76E-02 5.80E-02 5.78E-02 5.77E-02 5.76E-02 445 5.69E-02 5.71E-02 5.71E-02 5.69E-02 5.68E-02 474 5.71E-02 5.71E-02 5.73E-02 5.70E-02 5.69E-02 500 5.74E-02 5.74E-02 5.75E-02 5.73E-02 5.72E-02 518 5.67E-02 5.67E-02 5.65E-02 5.64E-02 5.64E-02 524 5.68E-02 5.70E-02 5.66E-02 5.68E-02 5.67E-02 558 5.76E-02 5.78E-02 5.74E-02 5.76E-02 5.75E-02 Biased Statistics Average Biased 5.74E-02 5.75E-02 5.72E-02 5.72E-02 5.70E-02 Std Dev Biased 3.70E-04 3.51E-04 4.25E-04 3.27E-04 3.03E-04 Ps90%/90% (+KTL) Biased 5.84E-02 5.84E-02 5.84E-02 5.81E-02 5.78E-02 Ps90%/90% (-KTL) Biased 5.64E-02 5.65E-02 5.60E-02 5.63E-02 5.62E-02 Un-Biased Statistics Average Un-Biased 5.72E-02 5.73E-02 5.72E-02 5.71E-02 5.70E-02 Std Dev Un-Biased 3.79E-04 4.77E-04 4.63E-04 4.65E-04 4.46E-04 Ps90%/90% (+KTL) Un-Biased 5.82E-02 5.86E-02 5.85E-02 5.84E-02 5.82E-02 Ps90%/90% (-KTL) Un-Biased 5.61E-02 5.59E-02 5.60E-02 5.58E-02 5.58E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 214 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.102. Plot of -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 215 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.102. Raw data for -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Short-Circuit Current1 4 15V (A) Total Dose (krad(Si)) @ VS=+/-15V, VOUT=0V Device 0 10 20 30 50 284 5.58E-02 5.56E-02 5.57E-02 5.56E-02 5.52E-02 303 5.65E-02 5.64E-02 5.63E-02 5.61E-02 5.59E-02 314 5.58E-02 5.57E-02 5.55E-02 5.54E-02 5.53E-02 331 5.61E-02 5.62E-02 5.58E-02 5.58E-02 5.57E-02 368 5.68E-02 5.71E-02 5.66E-02 5.66E-02 5.65E-02 404 5.59E-02 5.62E-02 5.61E-02 5.60E-02 5.58E-02 445 5.59E-02 5.61E-02 5.61E-02 5.60E-02 5.59E-02 474 5.60E-02 5.59E-02 5.61E-02 5.59E-02 5.58E-02 500 5.59E-02 5.58E-02 5.59E-02 5.57E-02 5.56E-02 518 5.59E-02 5.59E-02 5.57E-02 5.57E-02 5.56E-02 524 5.58E-02 5.60E-02 5.56E-02 5.58E-02 5.57E-02 558 5.62E-02 5.64E-02 5.60E-02 5.62E-02 5.61E-02 Biased Statistics Average Biased 5.62E-02 5.62E-02 5.60E-02 5.59E-02 5.57E-02 Std Dev Biased 4.50E-04 5.98E-04 4.68E-04 4.86E-04 5.20E-04 Ps90%/90% (+KTL) Biased 5.74E-02 5.78E-02 5.72E-02 5.72E-02 5.72E-02 Ps90%/90% (-KTL) Biased 5.49E-02 5.46E-02 5.47E-02 5.46E-02 5.43E-02 Un-Biased Statistics Average Un-Biased 5.59E-02 5.60E-02 5.60E-02 5.58E-02 5.57E-02 Std Dev Un-Biased 4.71E-05 1.81E-04 1.72E-04 1.58E-04 1.37E-04 Ps90%/90% (+KTL) Un-Biased 5.60E-02 5.65E-02 5.64E-02 5.63E-02 5.61E-02 Ps90%/90% (-KTL) Un-Biased 5.58E-02 5.55E-02 5.55E-02 5.54E-02 5.53E-02 Specification MIN 1.50E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 216 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Supply Current 5V (A) @ VS=+5V 9.00E-03 8.80E-03 8.60E-03 8.40E-03 8.20E-03 8.00E-03 7.80E-03 7.60E-03 7.40E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.103. Plot of +Supply Current 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 217 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.103. Raw data for +Supply Current 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Supply Current 5V (A) @ VS=+5V Device 284 303 314 331 368 404 445 474 500 518 524 558 0 7.85E-03 7.74E-03 7.81E-03 7.78E-03 7.80E-03 7.76E-03 7.73E-03 7.74E-03 7.79E-03 7.70E-03 7.93E-03 7.89E-03 Total 10 7.79E-03 7.65E-03 7.73E-03 7.66E-03 7.70E-03 7.73E-03 7.68E-03 7.72E-03 7.76E-03 7.67E-03 7.91E-03 7.87E-03 Dose (krad(Si)) 20 30 7.73E-03 7.70E-03 7.63E-03 7.60E-03 7.71E-03 7.69E-03 7.68E-03 7.65E-03 7.70E-03 7.67E-03 7.72E-03 7.72E-03 7.68E-03 7.68E-03 7.70E-03 7.70E-03 7.75E-03 7.74E-03 7.66E-03 7.66E-03 7.93E-03 7.92E-03 7.89E-03 7.88E-03 50 7.68E-03 7.58E-03 7.66E-03 7.62E-03 7.64E-03 7.70E-03 7.66E-03 7.68E-03 7.73E-03 7.63E-03 7.93E-03 7.89E-03 Biased Statistics Average Biased 7.79E-03 7.71E-03 7.69E-03 7.66E-03 7.63E-03 Std Dev Biased 4.19E-05 5.84E-05 4.03E-05 3.83E-05 3.85E-05 Ps90%/90% (+KTL) Biased 7.91E-03 7.87E-03 7.80E-03 7.77E-03 7.74E-03 Ps90%/90% (-KTL) Biased 7.68E-03 7.54E-03 7.58E-03 7.56E-03 7.53E-03 Un-Biased Statistics Average Un-Biased 7.74E-03 7.71E-03 7.70E-03 7.70E-03 7.68E-03 Std Dev Un-Biased 3.61E-05 3.74E-05 3.41E-05 3.37E-05 3.76E-05 Ps90%/90% (+KTL) Un-Biased 7.84E-03 7.81E-03 7.79E-03 7.79E-03 7.78E-03 Ps90%/90% (-KTL) Un-Biased 7.64E-03 7.61E-03 7.61E-03 7.61E-03 7.58E-03 Specification MAX 8.80E-03 8.80E-03 8.80E-03 8.80E-03 8.80E-03 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 218 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -7.40E-03 -Supply Current 5V (A) @ VS=+5V -7.60E-03 -7.80E-03 -8.00E-03 -8.20E-03 -8.40E-03 -8.60E-03 -8.80E-03 -9.00E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.104. Plot of -Supply Current 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 219 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.104. Raw data for -Supply Current 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Supply Current 5V (A) @ VS=+5V Device 284 303 314 331 368 404 445 474 500 518 524 558 0 -7.85E-03 -7.73E-03 -7.81E-03 -7.78E-03 -7.79E-03 -7.76E-03 -7.72E-03 -7.74E-03 -7.79E-03 -7.69E-03 -7.93E-03 -7.89E-03 Biased Statistics Average Biased -7.79E-03 Std Dev Biased 4.21E-05 Ps90%/90% (+KTL) Biased -7.68E-03 Ps90%/90% (-KTL) Biased -7.91E-03 Un-Biased Statistics Average Un-Biased -7.74E-03 Std Dev Un-Biased 3.65E-05 Ps90%/90% (+KTL) Un-Biased -7.64E-03 Ps90%/90% (-KTL) Un-Biased -7.84E-03 Specification MIN -8.80E-03 Status PASS Total 10 -7.79E-03 -7.65E-03 -7.72E-03 -7.66E-03 -7.70E-03 -7.72E-03 -7.68E-03 -7.71E-03 -7.76E-03 -7.66E-03 -7.91E-03 -7.87E-03 Dose (krad(Si)) 20 30 -7.73E-03 -7.70E-03 -7.62E-03 -7.60E-03 -7.71E-03 -7.68E-03 -7.68E-03 -7.65E-03 -7.69E-03 -7.67E-03 -7.72E-03 -7.71E-03 -7.68E-03 -7.68E-03 -7.69E-03 -7.69E-03 -7.74E-03 -7.74E-03 -7.66E-03 -7.65E-03 -7.93E-03 -7.92E-03 -7.89E-03 -7.88E-03 50 -7.68E-03 -7.57E-03 -7.66E-03 -7.62E-03 -7.64E-03 -7.70E-03 -7.66E-03 -7.68E-03 -7.73E-03 -7.63E-03 -7.93E-03 -7.89E-03 -7.70E-03 -7.68E-03 -7.66E-03 -7.63E-03 5.79E-05 3.98E-05 3.89E-05 3.94E-05 -7.54E-03 -7.58E-03 -7.55E-03 -7.52E-03 -7.86E-03 -7.79E-03 -7.77E-03 -7.74E-03 -7.71E-03 3.77E-05 -7.60E-03 -7.81E-03 -8.80E-03 PASS -7.70E-03 3.39E-05 -7.60E-03 -7.79E-03 -8.80E-03 PASS -7.69E-03 3.26E-05 -7.61E-03 -7.78E-03 -8.80E-03 PASS An ISO 9001:2008 and DSCC Certified Company 220 -7.68E-03 3.63E-05 -7.58E-03 -7.78E-03 -8.80E-03 PASS Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.105. Plot of Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 221 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.105. Raw data for Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.64E-04 2.57E-05 -3.87E-05 4.28E-05 1.79E-04 5.58E-05 3.08E-05 -1.52E-04 -1.82E-04 -2.01E-04 9.76E-05 -1.85E-04 Total 10 -2.96E-04 1.36E-05 -5.68E-05 2.25E-05 1.56E-04 4.50E-05 2.03E-05 -1.61E-04 -1.98E-04 -2.12E-04 9.53E-05 -1.85E-04 Dose (krad(Si)) 20 30 -2.87E-04 -2.83E-04 1.55E-05 1.93E-05 -5.21E-05 -5.14E-05 2.76E-05 3.13E-05 1.59E-04 1.56E-04 4.22E-05 3.82E-05 1.43E-05 1.25E-05 -1.67E-04 -1.70E-04 -2.03E-04 -2.07E-04 -2.16E-04 -2.20E-04 9.87E-05 9.77E-05 -1.81E-04 -1.84E-04 50 -2.75E-04 1.82E-05 -5.52E-05 2.77E-05 1.52E-04 2.99E-05 1.02E-05 -1.76E-04 -2.13E-04 -2.24E-04 9.82E-05 -1.84E-04 -1.09E-05 -3.21E-05 -2.73E-05 -2.54E-05 -2.63E-05 1.62E-04 1.66E-04 1.64E-04 1.62E-04 1.58E-04 4.33E-04 4.24E-04 4.23E-04 4.19E-04 4.06E-04 -4.55E-04 -4.88E-04 -4.77E-04 -4.70E-04 -4.59E-04 -8.98E-05 1.23E-04 2.48E-04 -4.27E-04 -8.00E-04 PASS 8.00E-04 PASS -1.01E-04 1.24E-04 2.38E-04 -4.40E-04 -9.50E-04 PASS 9.50E-04 PASS -1.06E-04 1.24E-04 2.35E-04 -4.46E-04 -9.50E-04 PASS 9.50E-04 PASS -1.09E-04 1.25E-04 2.32E-04 -4.51E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 222 -1.15E-04 1.24E-04 2.27E-04 -4.56E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.106. Plot of Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 223 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.106. Raw data for Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.59E-06 9.05E-05 3.16E-05 6.20E-05 1.21E-04 -1.37E-04 9.93E-05 -1.73E-04 -1.41E-05 -2.16E-04 -7.66E-05 -2.92E-04 Total 10 -1.81E-05 8.00E-05 1.61E-05 5.10E-05 9.28E-05 -1.53E-04 8.29E-05 -1.83E-04 -2.70E-05 -2.26E-04 -7.94E-05 -2.93E-04 Dose (krad(Si)) 20 30 -1.49E-05 -8.52E-06 8.49E-05 8.99E-05 2.09E-05 2.13E-05 5.38E-05 5.67E-05 1.00E-04 9.95E-05 -1.59E-04 -1.61E-04 7.88E-05 7.62E-05 -1.88E-04 -1.90E-04 -3.03E-05 -3.17E-05 -2.29E-04 -2.34E-04 -7.77E-05 -7.87E-05 -2.91E-04 -2.92E-04 50 -5.13E-06 9.28E-05 2.49E-05 6.09E-05 9.82E-05 -1.66E-04 7.24E-05 -1.96E-04 -3.83E-05 -2.36E-04 -7.81E-05 -2.91E-04 6.15E-05 4.44E-05 4.90E-05 5.18E-05 5.43E-05 4.67E-05 4.57E-05 4.69E-05 4.56E-05 4.43E-05 1.90E-04 1.70E-04 1.77E-04 1.77E-04 1.76E-04 -6.65E-05 -8.09E-05 -7.96E-05 -7.33E-05 -6.71E-05 -8.83E-05 1.29E-04 2.66E-04 -4.42E-04 -8.00E-04 PASS 8.00E-04 PASS -1.01E-04 1.27E-04 2.47E-04 -4.49E-04 -9.50E-04 PASS 9.50E-04 PASS -1.05E-04 1.27E-04 2.43E-04 -4.53E-04 -9.50E-04 PASS 9.50E-04 PASS -1.08E-04 1.28E-04 2.42E-04 -4.58E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 224 -1.13E-04 1.27E-04 2.36E-04 -4.62E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.107. Plot of Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 225 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.107. Raw data for Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 1.36E-04 1.08E-04 1.05E-04 1.14E-04 1.25E-04 3.70E-05 1.60E-05 1.54E-05 1.80E-05 1.71E-05 1.22E-04 1.02E-04 1.04E-04 1.04E-04 1.03E-04 5.28E-05 2.77E-05 3.43E-05 3.64E-05 4.05E-05 3.21E-04 2.93E-04 2.97E-04 2.98E-04 2.98E-04 -7.56E-05 -8.90E-05 -9.54E-05 -9.38E-05 -9.85E-05 8.09E-05 6.66E-05 6.03E-05 5.87E-05 5.39E-05 -1.42E-04 -1.55E-04 -1.61E-04 -1.61E-04 -1.67E-04 1.13E-04 1.01E-04 9.65E-05 9.68E-05 9.17E-05 3.52E-05 2.37E-05 2.36E-05 2.38E-05 1.73E-05 1.06E-04 1.03E-04 1.07E-04 1.07E-04 1.07E-04 8.01E-05 7.61E-05 7.93E-05 7.94E-05 8.06E-05 1.34E-04 1.09E-04 1.11E-04 1.14E-04 1.17E-04 1.13E-04 1.11E-04 1.12E-04 1.11E-04 1.11E-04 4.43E-04 4.13E-04 4.17E-04 4.18E-04 4.20E-04 -1.76E-04 -1.94E-04 -1.95E-04 -1.89E-04 -1.86E-04 2.32E-06 1.08E-04 2.97E-04 -2.93E-04 -8.00E-04 PASS 8.00E-04 PASS -1.06E-05 1.08E-04 2.85E-04 -3.07E-04 -9.50E-04 PASS 9.50E-04 PASS -1.53E-05 1.09E-04 2.83E-04 -3.14E-04 -9.50E-04 PASS 9.50E-04 PASS -1.52E-05 1.08E-04 2.82E-04 -3.13E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 226 -2.05E-05 1.08E-04 2.77E-04 -3.18E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.108. Plot of Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 227 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.108. Raw data for Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 2.36E-04 -2.30E-04 -1.28E-04 3.32E-04 1.18E-04 -4.30E-05 -1.79E-04 -3.63E-04 -1.12E-04 2.17E-04 2.72E-04 8.72E-05 Total 10 2.15E-04 -2.46E-04 -1.45E-04 3.08E-04 1.02E-04 -5.32E-05 -1.93E-04 -3.75E-04 -1.27E-04 2.05E-04 2.68E-04 8.52E-05 Dose (krad(Si)) 20 30 2.20E-04 2.27E-04 -2.43E-04 -2.38E-04 -1.42E-04 -1.43E-04 3.12E-04 3.11E-04 1.07E-04 1.11E-04 -5.66E-05 -5.74E-05 -1.97E-04 -1.99E-04 -3.79E-04 -3.81E-04 -1.30E-04 -1.34E-04 2.02E-04 2.00E-04 2.73E-04 2.71E-04 8.93E-05 8.83E-05 50 2.32E-04 -2.37E-04 -1.44E-04 3.12E-04 1.11E-04 -6.19E-05 -2.03E-04 -3.86E-04 -1.36E-04 1.92E-04 2.73E-04 9.00E-05 6.55E-05 4.68E-05 5.09E-05 5.34E-05 5.47E-05 2.39E-04 2.36E-04 2.36E-04 2.36E-04 2.37E-04 7.20E-04 6.93E-04 6.98E-04 7.02E-04 7.06E-04 -5.89E-04 -5.99E-04 -5.96E-04 -5.95E-04 -5.96E-04 -9.59E-05 2.12E-04 4.85E-04 -6.76E-04 -8.00E-04 PASS 8.00E-04 PASS -1.09E-04 2.12E-04 4.72E-04 -6.90E-04 -9.50E-04 PASS 9.50E-04 PASS -1.12E-04 2.12E-04 4.70E-04 -6.94E-04 -9.50E-04 PASS 9.50E-04 PASS -1.14E-04 2.12E-04 4.68E-04 -6.97E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 228 -1.19E-04 2.11E-04 4.60E-04 -6.98E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.109. Plot of Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 229 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.109. Raw data for Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -2.53E-09 -1.57E-09 -1.77E-09 -4.09E-09 -1.04E-09 -8.40E-10 -2.03E-09 2.16E-09 -8.50E-10 -9.80E-10 9.60E-10 -8.60E-10 Total 10 -3.02E-09 -1.41E-09 -2.00E-09 -3.52E-09 -1.31E-09 -4.40E-10 -2.02E-09 2.17E-09 -1.10E-09 -1.25E-09 9.60E-10 -8.20E-10 Dose (krad(Si)) 20 30 -2.80E-09 -3.88E-09 -7.50E-10 -3.70E-10 -1.94E-09 -2.40E-09 -3.45E-09 -3.77E-09 -1.44E-09 -1.76E-09 -6.60E-10 -2.60E-10 -1.66E-09 -1.64E-09 2.89E-09 3.07E-09 -7.50E-10 -1.43E-09 -1.79E-09 -1.98E-09 9.00E-10 8.60E-10 -8.00E-10 -7.50E-10 50 -3.55E-09 -7.90E-10 -2.31E-09 -3.69E-09 -1.70E-09 -7.10E-10 -1.92E-09 2.41E-09 -7.20E-10 -1.54E-09 9.20E-10 -7.80E-10 -2.20E-09 -2.25E-09 -2.08E-09 -2.44E-09 -2.41E-09 1.18E-09 9.82E-10 1.07E-09 1.47E-09 1.23E-09 1.05E-09 4.41E-10 8.62E-10 1.58E-09 9.72E-10 -5.45E-09 -4.94E-09 -5.01E-09 -6.45E-09 -5.79E-09 -5.08E-10 1.57E-09 3.80E-09 -4.82E-09 -6.50E-08 PASS 6.50E-08 PASS -5.28E-10 1.61E-09 3.89E-09 -4.94E-09 -6.50E-08 PASS 6.50E-08 PASS -3.94E-10 1.91E-09 4.83E-09 -5.62E-09 -6.50E-08 PASS 6.50E-08 PASS -4.48E-10 2.07E-09 5.23E-09 -6.12E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 230 -4.96E-10 1.71E-09 4.19E-09 -5.18E-09 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.110. Plot of Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 231 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.110. Raw data for Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 1.43E-09 1.31E-09 1.46E-09 1.14E-09 1.46E-09 2.90E-09 3.14E-09 3.09E-09 3.48E-09 3.51E-09 5.20E-10 7.50E-10 4.50E-10 8.20E-10 6.70E-10 -4.40E-10 7.60E-10 5.90E-10 4.60E-10 2.10E-10 -7.60E-10 -1.36E-09 -8.50E-10 -5.40E-10 -1.60E-10 1.53E-09 1.89E-09 2.48E-09 2.51E-09 3.18E-09 4.62E-09 4.86E-09 5.10E-09 5.38E-09 4.96E-09 -1.83E-09 -2.14E-09 -1.94E-09 -2.23E-09 -2.10E-09 3.10E-09 3.04E-09 2.83E-09 2.29E-09 2.09E-09 -2.36E-09 -2.29E-09 -2.56E-09 -2.50E-09 -3.17E-09 5.73E-09 5.79E-09 5.77E-09 5.78E-09 5.75E-09 1.25E-09 1.32E-09 1.36E-09 1.29E-09 1.31E-09 7.30E-10 9.20E-10 9.48E-10 1.07E-09 1.14E-09 1.49E-09 1.61E-09 1.45E-09 1.49E-09 1.46E-09 4.80E-09 5.33E-09 4.94E-09 5.15E-09 5.13E-09 -3.34E-09 -3.49E-09 -3.04E-09 -3.00E-09 -2.86E-09 1.01E-09 3.05E-09 9.36E-09 -7.34E-09 -6.50E-08 PASS 6.50E-08 PASS 1.07E-09 3.18E-09 9.80E-09 -7.65E-09 -6.50E-08 PASS 6.50E-08 PASS 1.18E-09 3.30E-09 1.02E-08 -7.86E-09 -6.50E-08 PASS 6.50E-08 PASS 1.09E-09 3.38E-09 1.04E-08 -8.19E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 232 9.92E-10 3.49E-09 1.06E-08 -8.57E-09 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.111. Plot of Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 233 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.111. Raw data for Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 2.38E-09 1.78E-09 2.29E-09 2.35E-09 3.31E-09 -2.49E-09 -2.45E-09 -2.42E-09 -2.43E-09 -1.82E-09 9.50E-10 7.90E-10 1.01E-09 9.60E-10 4.80E-10 4.20E-09 4.30E-09 4.35E-09 4.73E-09 4.41E-09 5.91E-09 5.30E-09 5.91E-09 5.41E-09 5.93E-09 2.88E-09 3.04E-09 3.00E-09 3.07E-09 2.87E-09 -1.11E-09 -1.56E-09 -8.70E-10 -1.26E-09 -1.16E-09 -3.12E-09 -2.90E-09 -3.32E-09 -3.27E-09 -3.15E-09 2.42E-09 2.65E-09 2.42E-09 2.66E-09 1.70E-09 5.17E-09 5.09E-09 4.95E-09 5.53E-09 5.25E-09 1.70E-09 1.74E-09 1.64E-09 1.73E-09 1.70E-09 3.39E-09 3.38E-09 3.42E-09 3.38E-09 3.36E-09 2.19E-09 1.94E-09 2.23E-09 2.20E-09 2.46E-09 3.22E-09 3.06E-09 3.21E-09 3.15E-09 3.11E-09 1.10E-08 1.03E-08 1.10E-08 1.08E-08 1.10E-08 -6.63E-09 -6.45E-09 -6.57E-09 -6.43E-09 -6.08E-09 1.25E-09 3.32E-09 1.03E-08 -7.85E-09 -6.50E-08 PASS 6.50E-08 PASS 1.26E-09 3.36E-09 1.05E-08 -7.94E-09 -6.50E-08 PASS 6.50E-08 PASS 1.24E-09 3.30E-09 1.03E-08 -7.81E-09 -6.50E-08 PASS 6.50E-08 PASS 1.35E-09 3.55E-09 1.11E-08 -8.38E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 234 1.10E-09 3.31E-09 1.02E-08 -7.98E-09 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.112. Plot of Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 235 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.112. Raw data for Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 4.21E-09 4.39E-09 4.68E-09 4.40E-09 5.14E-09 3.77E-09 3.30E-09 3.73E-09 3.91E-09 4.25E-09 1.52E-09 1.69E-09 2.01E-09 1.97E-09 2.36E-09 3.24E-09 3.07E-09 2.97E-09 3.35E-09 3.10E-09 8.04E-09 7.93E-09 7.63E-09 7.64E-09 7.77E-09 1.09E-09 1.15E-09 1.92E-09 1.92E-09 2.40E-09 -4.68E-09 -4.67E-09 -4.11E-09 -3.93E-09 -3.62E-09 -2.90E-10 -3.00E-10 -5.30E-10 -5.10E-10 5.20E-10 -2.59E-09 -2.38E-09 -2.58E-09 -3.03E-09 -2.67E-09 5.10E-10 8.60E-10 7.40E-10 1.31E-09 1.54E-09 3.00E-10 2.70E-10 3.30E-10 2.90E-10 3.10E-10 4.44E-09 4.48E-09 4.53E-09 4.47E-09 4.51E-09 4.16E-09 4.08E-09 4.20E-09 4.25E-09 4.52E-09 2.40E-09 2.36E-09 2.15E-09 2.10E-09 2.10E-09 1.07E-08 1.05E-08 1.01E-08 1.00E-08 1.03E-08 -2.42E-09 -2.39E-09 -1.70E-09 -1.50E-09 -1.24E-09 -1.19E-09 2.40E-09 5.39E-09 -7.77E-09 -6.50E-08 PASS 6.50E-08 PASS -1.07E-09 2.45E-09 5.64E-09 -7.77E-09 -6.50E-08 PASS 6.50E-08 PASS -9.12E-10 2.44E-09 5.79E-09 -7.62E-09 -6.50E-08 PASS 6.50E-08 PASS -8.48E-10 2.58E-09 6.24E-09 -7.93E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 236 -3.66E-10 2.64E-09 6.88E-09 -7.62E-09 -6.50E-08 PASS 6.50E-08 PASS +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.113. Plot of +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 237 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.113. Raw data for +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.58E-07 -3.72E-07 -3.65E-07 -3.88E-07 -3.54E-07 -3.63E-07 -3.31E-07 -3.75E-07 -3.87E-07 -3.64E-07 -3.74E-07 -3.41E-07 Total 10 -3.61E-07 -3.76E-07 -3.71E-07 -3.98E-07 -3.61E-07 -3.69E-07 -3.39E-07 -3.81E-07 -3.92E-07 -3.71E-07 -3.76E-07 -3.48E-07 Dose (krad(Si)) 20 30 -3.70E-07 -3.74E-07 -3.83E-07 -3.84E-07 -3.75E-07 -3.79E-07 -3.98E-07 -4.02E-07 -3.65E-07 -3.70E-07 -3.75E-07 -3.78E-07 -3.49E-07 -3.53E-07 -3.89E-07 -3.91E-07 -3.99E-07 -4.04E-07 -3.76E-07 -3.79E-07 -3.73E-07 -3.73E-07 -3.40E-07 -3.41E-07 50 -3.81E-07 -3.93E-07 -3.87E-07 -4.10E-07 -3.78E-07 -3.87E-07 -3.64E-07 -4.01E-07 -4.12E-07 -3.90E-07 -3.74E-07 -3.40E-07 -3.68E-07 -3.74E-07 -3.78E-07 -3.82E-07 -3.90E-07 1.37E-08 1.51E-08 1.29E-08 1.24E-08 1.29E-08 -3.30E-07 -3.32E-07 -3.43E-07 -3.48E-07 -3.55E-07 -4.05E-07 -4.15E-07 -4.13E-07 -4.16E-07 -4.25E-07 -3.64E-07 2.07E-08 -3.07E-07 -4.21E-07 -6.50E-07 PASS 6.50E-07 PASS -3.70E-07 2.00E-08 -3.15E-07 -4.25E-07 -7.00E-07 PASS 7.00E-07 PASS -3.78E-07 1.87E-08 -3.27E-07 -4.29E-07 -7.50E-07 PASS 7.50E-07 PASS An ISO 9001:2008 and DSCC Certified Company 238 -3.81E-07 1.88E-08 -3.30E-07 -4.33E-07 -7.50E-07 PASS 7.50E-07 PASS -3.91E-07 1.81E-08 -3.41E-07 -4.40E-07 -8.00E-07 PASS 8.00E-07 PASS +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.114. Plot of +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 239 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.114. Raw data for +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.59E-07 -3.70E-07 -3.71E-07 -3.79E-07 -3.39E-07 -3.45E-07 -3.33E-07 -3.77E-07 -3.77E-07 -3.63E-07 -3.60E-07 -3.52E-07 Total 10 -3.63E-07 -3.73E-07 -3.76E-07 -3.89E-07 -3.52E-07 -3.53E-07 -3.45E-07 -3.82E-07 -3.83E-07 -3.71E-07 -3.61E-07 -3.55E-07 Dose (krad(Si)) 20 30 -3.71E-07 -3.74E-07 -3.80E-07 -3.82E-07 -3.81E-07 -3.83E-07 -3.87E-07 -3.92E-07 -3.56E-07 -3.60E-07 -3.56E-07 -3.63E-07 -3.52E-07 -3.56E-07 -3.91E-07 -3.93E-07 -3.92E-07 -3.97E-07 -3.75E-07 -3.80E-07 -3.57E-07 -3.59E-07 -3.52E-07 -3.53E-07 50 -3.81E-07 -3.90E-07 -3.93E-07 -4.01E-07 -3.69E-07 -3.69E-07 -3.64E-07 -4.02E-07 -4.06E-07 -3.88E-07 -3.59E-07 -3.53E-07 -3.64E-07 -3.70E-07 -3.75E-07 -3.78E-07 -3.87E-07 1.52E-08 1.39E-08 1.23E-08 1.20E-08 1.21E-08 -3.22E-07 -3.32E-07 -3.41E-07 -3.45E-07 -3.54E-07 -4.05E-07 -4.09E-07 -4.09E-07 -4.11E-07 -4.20E-07 -3.59E-07 1.94E-08 -3.06E-07 -4.12E-07 -6.50E-07 PASS 6.50E-07 PASS -3.67E-07 1.73E-08 -3.19E-07 -4.14E-07 -7.00E-07 PASS 7.00E-07 PASS -3.73E-07 1.87E-08 -3.22E-07 -4.25E-07 -7.50E-07 PASS 7.50E-07 PASS An ISO 9001:2008 and DSCC Certified Company 240 -3.78E-07 1.82E-08 -3.28E-07 -4.28E-07 -7.50E-07 PASS 7.50E-07 PASS -3.86E-07 1.90E-08 -3.34E-07 -4.38E-07 -8.00E-07 PASS 8.00E-07 PASS +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.115. Plot of +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 241 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.115. Raw data for +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.60E-07 -3.74E-07 -3.68E-07 -3.78E-07 -3.38E-07 -3.36E-07 -3.38E-07 -3.84E-07 -3.74E-07 -3.60E-07 -3.64E-07 -3.52E-07 Total 10 -3.63E-07 -3.78E-07 -3.73E-07 -3.87E-07 -3.50E-07 -3.47E-07 -3.50E-07 -3.88E-07 -3.80E-07 -3.68E-07 -3.65E-07 -3.54E-07 Dose (krad(Si)) 20 30 -3.74E-07 -3.76E-07 -3.85E-07 -3.86E-07 -3.77E-07 -3.79E-07 -3.87E-07 -3.91E-07 -3.54E-07 -3.58E-07 -3.52E-07 -3.57E-07 -3.57E-07 -3.61E-07 -3.97E-07 -4.00E-07 -3.88E-07 -3.91E-07 -3.73E-07 -3.77E-07 -3.61E-07 -3.63E-07 -3.52E-07 -3.52E-07 50 -3.80E-07 -3.93E-07 -3.90E-07 -4.01E-07 -3.68E-07 -3.67E-07 -3.71E-07 -4.09E-07 -4.01E-07 -3.87E-07 -3.63E-07 -3.53E-07 -3.63E-07 -3.70E-07 -3.76E-07 -3.78E-07 -3.86E-07 1.59E-08 1.44E-08 1.31E-08 1.25E-08 1.26E-08 -3.20E-07 -3.31E-07 -3.40E-07 -3.44E-07 -3.52E-07 -4.07E-07 -4.10E-07 -4.12E-07 -4.12E-07 -4.21E-07 -3.58E-07 2.13E-08 -3.00E-07 -4.17E-07 -6.50E-07 PASS 6.50E-07 PASS -3.67E-07 1.80E-08 -3.17E-07 -4.16E-07 -7.00E-07 PASS 7.00E-07 PASS -3.73E-07 1.93E-08 -3.21E-07 -4.26E-07 -7.50E-07 PASS 7.50E-07 PASS An ISO 9001:2008 and DSCC Certified Company 242 -3.77E-07 1.87E-08 -3.26E-07 -4.28E-07 -7.50E-07 PASS 7.50E-07 PASS -3.87E-07 1.84E-08 -3.36E-07 -4.37E-07 -8.00E-07 PASS 8.00E-07 PASS +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.116. Plot of +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 243 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.116. Raw data for +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.50E-07 -3.74E-07 -3.67E-07 -3.90E-07 -3.56E-07 -3.61E-07 -3.37E-07 -3.81E-07 -3.85E-07 -3.66E-07 -3.76E-07 -3.32E-07 Total 10 -3.54E-07 -3.79E-07 -3.72E-07 -3.99E-07 -3.66E-07 -3.69E-07 -3.48E-07 -3.86E-07 -3.91E-07 -3.73E-07 -3.78E-07 -3.33E-07 Dose (krad(Si)) 20 30 -3.62E-07 -3.67E-07 -3.85E-07 -3.87E-07 -3.76E-07 -3.80E-07 -3.97E-07 -4.04E-07 -3.71E-07 -3.76E-07 -3.76E-07 -3.80E-07 -3.54E-07 -3.59E-07 -3.95E-07 -3.99E-07 -3.97E-07 -4.01E-07 -3.77E-07 -3.81E-07 -3.74E-07 -3.77E-07 -3.31E-07 -3.32E-07 50 -3.73E-07 -3.94E-07 -3.91E-07 -4.12E-07 -3.86E-07 -3.89E-07 -3.67E-07 -4.05E-07 -4.10E-07 -3.91E-07 -3.76E-07 -3.31E-07 -3.67E-07 -3.74E-07 -3.78E-07 -3.83E-07 -3.91E-07 1.57E-08 1.69E-08 1.33E-08 1.36E-08 1.40E-08 -3.24E-07 -3.28E-07 -3.42E-07 -3.45E-07 -3.52E-07 -4.11E-07 -4.20E-07 -4.15E-07 -4.20E-07 -4.30E-07 -3.66E-07 1.92E-08 -3.14E-07 -4.19E-07 -6.50E-07 PASS 6.50E-07 PASS -3.73E-07 1.67E-08 -3.28E-07 -4.19E-07 -7.00E-07 PASS 7.00E-07 PASS -3.80E-07 1.74E-08 -3.32E-07 -4.28E-07 -7.50E-07 PASS 7.50E-07 PASS An ISO 9001:2008 and DSCC Certified Company 244 -3.84E-07 1.68E-08 -3.38E-07 -4.30E-07 -7.50E-07 PASS 7.50E-07 PASS -3.92E-07 1.68E-08 -3.46E-07 -4.38E-07 -8.00E-07 PASS 8.00E-07 PASS -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.117. Plot of -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 245 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.117. Raw data for -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.57E-07 -3.71E-07 -3.65E-07 -3.84E-07 -3.53E-07 -3.61E-07 -3.31E-07 -3.79E-07 -3.87E-07 -3.64E-07 -3.76E-07 -3.46E-07 Total 10 -3.59E-07 -3.75E-07 -3.70E-07 -3.95E-07 -3.60E-07 -3.69E-07 -3.38E-07 -3.84E-07 -3.92E-07 -3.70E-07 -3.77E-07 -3.48E-07 Dose (krad(Si)) 20 30 -3.68E-07 -3.71E-07 -3.81E-07 -3.85E-07 -3.75E-07 -3.76E-07 -3.94E-07 -3.99E-07 -3.64E-07 -3.68E-07 -3.74E-07 -3.78E-07 -3.48E-07 -3.52E-07 -3.92E-07 -3.95E-07 -4.00E-07 -4.03E-07 -3.75E-07 -3.79E-07 -3.73E-07 -3.75E-07 -3.41E-07 -3.48E-07 50 -3.78E-07 -3.91E-07 -3.87E-07 -4.09E-07 -3.75E-07 -3.85E-07 -3.61E-07 -4.04E-07 -4.12E-07 -3.89E-07 -3.75E-07 -3.41E-07 -3.66E-07 -3.72E-07 -3.77E-07 -3.80E-07 -3.88E-07 1.23E-08 1.49E-08 1.19E-08 1.23E-08 1.32E-08 -3.32E-07 -3.31E-07 -3.44E-07 -3.46E-07 -3.52E-07 -4.00E-07 -4.13E-07 -4.09E-07 -4.14E-07 -4.24E-07 -3.64E-07 2.16E-08 -3.05E-07 -4.24E-07 -6.50E-07 PASS 6.50E-07 PASS -3.71E-07 2.07E-08 -3.14E-07 -4.27E-07 -7.00E-07 PASS 7.00E-07 PASS -3.78E-07 2.00E-08 -3.23E-07 -4.33E-07 -7.50E-07 PASS 7.50E-07 PASS -3.82E-07 1.94E-08 -3.28E-07 -4.35E-07 -7.50E-07 PASS 7.50E-07 PASS An ISO 9001:2008 and DSCC Certified Company 246 -3.90E-07 1.96E-08 -3.36E-07 -4.44E-07 -8.00E-07 PASS 8.00E-07 PASS -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.118. Plot of -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 247 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.118. Raw data for -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.61E-07 -3.73E-07 -3.71E-07 -3.79E-07 -3.40E-07 -3.47E-07 -3.39E-07 -3.77E-07 -3.82E-07 -3.63E-07 -3.67E-07 -3.55E-07 Total 10 -3.66E-07 -3.78E-07 -3.78E-07 -3.90E-07 -3.50E-07 -3.56E-07 -3.50E-07 -3.81E-07 -3.88E-07 -3.69E-07 -3.68E-07 -3.58E-07 Dose (krad(Si)) 20 30 -3.73E-07 -3.78E-07 -3.83E-07 -3.88E-07 -3.81E-07 -3.85E-07 -3.89E-07 -3.91E-07 -3.55E-07 -3.60E-07 -3.61E-07 -3.66E-07 -3.59E-07 -3.61E-07 -3.90E-07 -3.92E-07 -3.95E-07 -3.99E-07 -3.74E-07 -3.78E-07 -3.65E-07 -3.67E-07 -3.54E-07 -3.56E-07 50 -3.85E-07 -3.95E-07 -3.95E-07 -4.01E-07 -3.69E-07 -3.73E-07 -3.70E-07 -4.02E-07 -4.09E-07 -3.87E-07 -3.65E-07 -3.56E-07 -3.65E-07 -3.72E-07 -3.76E-07 -3.81E-07 -3.89E-07 1.51E-08 1.53E-08 1.30E-08 1.24E-08 1.27E-08 -3.24E-07 -3.30E-07 -3.41E-07 -3.46E-07 -3.54E-07 -4.06E-07 -4.14E-07 -4.12E-07 -4.15E-07 -4.24E-07 -3.62E-07 1.83E-08 -3.11E-07 -4.12E-07 -6.50E-07 PASS 6.50E-07 PASS -3.69E-07 1.60E-08 -3.25E-07 -4.13E-07 -7.00E-07 PASS 7.00E-07 PASS -3.76E-07 1.64E-08 -3.31E-07 -4.21E-07 -7.50E-07 PASS 7.50E-07 PASS -3.79E-07 1.63E-08 -3.35E-07 -4.24E-07 -7.50E-07 PASS 7.50E-07 PASS An ISO 9001:2008 and DSCC Certified Company 248 -3.88E-07 1.73E-08 -3.41E-07 -4.35E-07 -8.00E-07 PASS 8.00E-07 PASS -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.119. Plot of -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 249 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.119. Raw data for -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.63E-07 -3.72E-07 -3.70E-07 -3.83E-07 -3.48E-07 -3.41E-07 -3.38E-07 -3.82E-07 -3.78E-07 -3.66E-07 -3.66E-07 -3.57E-07 Total 10 -3.66E-07 -3.77E-07 -3.74E-07 -3.94E-07 -3.55E-07 -3.51E-07 -3.48E-07 -3.87E-07 -3.82E-07 -3.74E-07 -3.68E-07 -3.59E-07 Dose (krad(Si)) 20 30 -3.74E-07 -3.79E-07 -3.83E-07 -3.85E-07 -3.79E-07 -3.81E-07 -3.94E-07 -3.97E-07 -3.60E-07 -3.64E-07 -3.58E-07 -3.62E-07 -3.56E-07 -3.60E-07 -3.95E-07 -3.98E-07 -3.91E-07 -3.95E-07 -3.78E-07 -3.83E-07 -3.64E-07 -3.65E-07 -3.54E-07 -3.57E-07 50 -3.88E-07 -3.93E-07 -3.91E-07 -4.05E-07 -3.73E-07 -3.70E-07 -3.68E-07 -4.07E-07 -4.03E-07 -3.92E-07 -3.66E-07 -3.56E-07 -3.67E-07 -3.73E-07 -3.78E-07 -3.81E-07 -3.90E-07 1.29E-08 1.44E-08 1.23E-08 1.17E-08 1.14E-08 -3.32E-07 -3.34E-07 -3.44E-07 -3.49E-07 -3.59E-07 -4.03E-07 -4.13E-07 -4.12E-07 -4.13E-07 -4.21E-07 -3.61E-07 2.05E-08 -3.05E-07 -4.17E-07 -6.50E-07 PASS 6.50E-07 PASS -3.68E-07 1.78E-08 -3.20E-07 -4.17E-07 -7.00E-07 PASS 7.00E-07 PASS -3.76E-07 1.82E-08 -3.26E-07 -4.26E-07 -7.50E-07 PASS 7.50E-07 PASS -3.80E-07 1.80E-08 -3.30E-07 -4.29E-07 -7.50E-07 PASS 7.50E-07 PASS An ISO 9001:2008 and DSCC Certified Company 250 -3.88E-07 1.83E-08 -3.38E-07 -4.39E-07 -8.00E-07 PASS 8.00E-07 PASS -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.120. Plot of -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 251 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.120. Raw data for -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -3.56E-07 -3.78E-07 -3.70E-07 -3.92E-07 -3.66E-07 -3.64E-07 -3.34E-07 -3.83E-07 -3.82E-07 -3.68E-07 -3.76E-07 -3.38E-07 Total 10 -3.60E-07 -3.83E-07 -3.75E-07 -4.03E-07 -3.74E-07 -3.72E-07 -3.41E-07 -3.87E-07 -3.89E-07 -3.75E-07 -3.77E-07 -3.39E-07 Dose (krad(Si)) 20 30 -3.68E-07 -3.73E-07 -3.90E-07 -3.93E-07 -3.81E-07 -3.83E-07 -4.02E-07 -4.05E-07 -3.79E-07 -3.84E-07 -3.77E-07 -3.84E-07 -3.52E-07 -3.57E-07 -3.97E-07 -3.99E-07 -3.95E-07 -3.98E-07 -3.77E-07 -3.83E-07 -3.75E-07 -3.77E-07 -3.37E-07 -3.38E-07 50 -3.80E-07 -4.00E-07 -3.93E-07 -4.16E-07 -3.94E-07 -3.90E-07 -3.65E-07 -4.08E-07 -4.07E-07 -3.92E-07 -3.76E-07 -3.38E-07 -3.72E-07 -3.79E-07 -3.84E-07 -3.88E-07 -3.97E-07 1.34E-08 1.59E-08 1.26E-08 1.20E-08 1.31E-08 -3.36E-07 -3.36E-07 -3.49E-07 -3.55E-07 -3.61E-07 -4.09E-07 -4.22E-07 -4.19E-07 -4.21E-07 -4.32E-07 -3.66E-07 2.00E-08 -3.11E-07 -4.21E-07 -6.50E-07 PASS 6.50E-07 PASS -3.73E-07 1.91E-08 -3.20E-07 -4.25E-07 -7.00E-07 PASS 7.00E-07 PASS -3.80E-07 1.81E-08 -3.30E-07 -4.29E-07 -7.50E-07 PASS 7.50E-07 PASS -3.84E-07 1.71E-08 -3.37E-07 -4.31E-07 -7.50E-07 PASS 7.50E-07 PASS An ISO 9001:2008 and DSCC Certified Company 252 -3.92E-07 1.73E-08 -3.45E-07 -4.40E-07 -8.00E-07 PASS 8.00E-07 PASS Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.121. Plot of Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 253 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.121. Raw data for Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.36E-05 1.33E-05 -2.08E-05 1.63E-04 2.88E-04 2.14E-04 6.36E-05 -1.44E-04 -6.30E-05 1.06E-04 1.52E-04 4.20E-05 Total 10 -3.07E-05 4.04E-06 -3.13E-05 1.47E-04 2.69E-04 2.08E-04 5.66E-05 -1.51E-04 -7.69E-05 9.65E-05 1.51E-04 4.20E-05 Dose (krad(Si)) 20 30 -2.30E-05 -1.89E-05 4.52E-06 7.78E-06 -2.65E-05 -2.26E-05 1.51E-04 1.56E-04 2.75E-04 2.73E-04 2.07E-04 2.04E-04 5.38E-05 5.31E-05 -1.55E-04 -1.59E-04 -7.88E-05 -8.11E-05 9.42E-05 9.27E-05 1.54E-04 1.53E-04 4.51E-05 4.38E-05 50 -1.52E-05 6.94E-06 -2.26E-05 1.55E-04 2.72E-04 2.01E-04 5.26E-05 -1.64E-04 -8.32E-05 8.94E-05 1.53E-04 4.39E-05 8.60E-05 7.16E-05 7.62E-05 7.91E-05 7.93E-05 1.36E-04 1.33E-04 1.33E-04 1.31E-04 1.30E-04 4.58E-04 4.35E-04 4.41E-04 4.38E-04 4.35E-04 -2.86E-04 -2.92E-04 -2.88E-04 -2.80E-04 -2.77E-04 3.52E-05 1.41E-04 4.22E-04 -3.51E-04 -8.00E-04 PASS 8.00E-04 PASS 2.66E-05 1.42E-04 4.17E-04 -3.64E-04 -9.50E-04 PASS 9.50E-04 PASS 2.43E-05 1.43E-04 4.17E-04 -3.69E-04 -9.50E-04 PASS 9.50E-04 PASS 2.21E-05 1.44E-04 4.16E-04 -3.72E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 254 1.92E-05 1.44E-04 4.14E-04 -3.76E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.122. Plot of Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 255 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.122. Raw data for Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 1.64E-04 3.16E-04 7.90E-06 1.51E-04 9.10E-05 7.66E-06 2.45E-04 -1.27E-06 1.65E-04 -1.41E-05 1.32E-04 -3.94E-05 Total 10 1.45E-04 3.03E-04 -2.36E-06 1.42E-04 6.82E-05 -7.43E-06 2.33E-04 -9.00E-06 1.55E-04 -2.07E-05 1.30E-04 -3.95E-05 Dose (krad(Si)) 20 30 1.51E-04 1.59E-04 3.07E-04 3.12E-04 3.56E-06 5.01E-06 1.45E-04 1.47E-04 7.44E-05 7.43E-05 -1.15E-05 -1.36E-05 2.31E-04 2.29E-04 -1.26E-05 -1.47E-05 1.55E-04 1.55E-04 -2.12E-05 -2.39E-05 1.32E-04 1.30E-04 -3.87E-05 -3.92E-05 50 1.63E-04 3.13E-04 8.02E-06 1.55E-04 7.54E-05 -1.72E-05 2.29E-04 -1.82E-05 1.51E-04 -2.55E-05 1.31E-04 -3.82E-05 1.46E-04 1.31E-04 1.36E-04 1.40E-04 1.43E-04 1.13E-04 1.14E-04 1.13E-04 1.14E-04 1.14E-04 4.57E-04 4.42E-04 4.46E-04 4.54E-04 4.56E-04 -1.65E-04 -1.80E-04 -1.73E-04 -1.74E-04 -1.71E-04 8.05E-05 1.18E-04 4.03E-04 -2.42E-04 -8.00E-04 PASS 8.00E-04 PASS 7.01E-05 1.16E-04 3.89E-04 -2.49E-04 -9.50E-04 PASS 9.50E-04 PASS 6.81E-05 1.17E-04 3.89E-04 -2.53E-04 -9.50E-04 PASS 9.50E-04 PASS 6.64E-05 1.18E-04 3.89E-04 -2.56E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 256 6.38E-05 1.18E-04 3.89E-04 -2.61E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.123. Plot of Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 257 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.123. Raw data for Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 2.08E-04 1.90E-04 2.01E-04 2.01E-04 2.12E-04 1.42E-04 1.28E-04 1.33E-04 1.35E-04 1.35E-04 1.25E-04 1.13E-04 1.19E-04 1.19E-04 1.20E-04 2.35E-04 2.27E-04 2.24E-04 2.25E-04 2.30E-04 2.81E-04 2.57E-04 2.64E-04 2.62E-04 2.64E-04 -1.25E-04 -1.36E-04 -1.38E-04 -1.41E-04 -1.43E-04 7.12E-05 6.24E-05 6.13E-05 5.49E-05 5.25E-05 1.21E-04 1.11E-04 1.10E-04 1.04E-04 9.98E-05 1.80E-07 -7.55E-06 -7.67E-06 -1.17E-05 -1.52E-05 2.01E-04 1.94E-04 1.94E-04 1.91E-04 1.89E-04 3.45E-04 3.48E-04 3.47E-04 3.44E-04 3.44E-04 1.60E-04 1.61E-04 1.60E-04 1.60E-04 1.61E-04 1.98E-04 6.50E-05 3.76E-04 2.01E-05 1.83E-04 6.21E-05 3.53E-04 1.27E-05 1.88E-04 6.14E-05 3.57E-04 2.00E-05 1.88E-04 6.06E-05 3.54E-04 2.23E-05 1.92E-04 6.22E-05 3.63E-04 2.16E-05 5.36E-05 1.24E-04 3.93E-04 -2.86E-04 -8.00E-04 PASS 8.00E-04 PASS 4.48E-05 1.25E-04 3.87E-04 -2.98E-04 -9.50E-04 PASS 9.50E-04 PASS 4.38E-05 1.25E-04 3.87E-04 -3.00E-04 -9.50E-04 PASS 9.50E-04 PASS 3.96E-05 1.25E-04 3.82E-04 -3.03E-04 -9.50E-04 PASS 9.50E-04 PASS 3.66E-05 1.25E-04 3.79E-04 -3.06E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 258 Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.50E-03 1.00E-03 5.00E-04 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.124. Plot of Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 259 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.124. Raw data for Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 3.54E-04 3.35E-04 3.40E-04 3.47E-04 3.55E-04 8.18E-05 6.22E-05 6.44E-05 6.68E-05 6.69E-05 8.52E-05 7.02E-05 7.38E-05 7.35E-05 7.35E-05 2.84E-04 2.63E-04 2.67E-04 2.67E-04 2.66E-04 2.27E-04 2.11E-04 2.15E-04 2.17E-04 2.19E-04 2.56E-04 2.49E-04 2.47E-04 2.46E-04 2.42E-04 -2.41E-04 -2.53E-04 -2.57E-04 -2.59E-04 -2.60E-04 -2.16E-04 -2.27E-04 -2.29E-04 -2.31E-04 -2.32E-04 -3.75E-05 -5.28E-05 -5.26E-05 -5.57E-05 -5.71E-05 2.95E-04 2.84E-04 2.84E-04 2.81E-04 2.77E-04 1.35E-04 1.32E-04 1.35E-04 1.34E-04 1.34E-04 2.26E-04 2.25E-04 2.27E-04 2.26E-04 2.27E-04 2.06E-04 1.88E-04 1.92E-04 1.94E-04 1.96E-04 1.21E-04 1.20E-04 1.21E-04 1.22E-04 1.25E-04 5.37E-04 5.17E-04 5.23E-04 5.30E-04 5.38E-04 -1.25E-04 -1.40E-04 -1.39E-04 -1.42E-04 -1.46E-04 1.12E-05 2.54E-04 7.08E-04 -6.85E-04 -8.00E-04 PASS 8.00E-04 PASS 8.00E-09 2.55E-04 7.00E-04 -7.00E-04 -9.50E-04 PASS 9.50E-04 PASS -1.59E-06 2.56E-04 7.01E-04 -7.04E-04 -9.50E-04 PASS 9.50E-04 PASS -3.73E-06 2.56E-04 6.99E-04 -7.07E-04 -9.50E-04 PASS 9.50E-04 PASS An ISO 9001:2008 and DSCC Certified Company 260 -6.32E-06 2.55E-04 6.93E-04 -7.05E-04 -9.50E-04 PASS 9.50E-04 PASS Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.125. Plot of Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 261 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.125. Raw data for Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -8.08E-09 -8.28E-09 -1.20E-09 1.42E-09 -6.72E-09 8.19E-09 1.19E-09 -3.70E-09 1.30E-08 2.80E-09 1.45E-09 2.62E-09 Total 10 -5.64E-09 -8.10E-09 -1.20E-09 5.00E-10 -6.42E-09 8.65E-09 1.31E-09 -3.45E-09 1.35E-08 2.19E-09 1.31E-09 2.50E-09 Dose (krad(Si)) 20 30 -3.96E-09 -3.99E-09 -9.51E-09 -9.48E-09 -2.70E-10 4.30E-10 1.16E-09 1.80E-09 -6.63E-09 -6.50E-09 9.16E-09 8.39E-09 1.31E-09 1.52E-09 -3.86E-09 -4.32E-09 1.45E-08 1.37E-08 3.23E-09 3.93E-09 1.50E-09 1.49E-09 2.56E-09 2.60E-09 50 -3.61E-09 -9.80E-09 7.50E-10 1.03E-09 -7.19E-09 8.69E-09 2.63E-09 -4.11E-09 1.50E-08 4.54E-09 1.48E-09 2.57E-09 -4.57E-09 -4.17E-09 -3.84E-09 -3.55E-09 -3.76E-09 4.41E-09 3.65E-09 4.41E-09 4.70E-09 4.78E-09 7.53E-09 5.84E-09 8.24E-09 9.35E-09 9.35E-09 -1.67E-08 -1.42E-08 -1.59E-08 -1.64E-08 -1.69E-08 4.30E-09 6.47E-09 2.20E-08 -1.34E-08 -6.50E-08 PASS 6.50E-08 PASS 4.44E-09 6.64E-09 2.27E-08 -1.38E-08 -6.50E-08 PASS 6.50E-08 PASS 4.87E-09 7.12E-09 2.44E-08 -1.47E-08 -6.50E-08 PASS 6.50E-08 PASS 4.65E-09 6.84E-09 2.34E-08 -1.41E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 262 5.34E-09 7.09E-09 2.48E-08 -1.41E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.126. Plot of Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 263 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.126. Raw data for Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 2.19E-09 4.27E-09 5.40E-09 5.38E-09 5.82E-09 1.17E-09 1.03E-09 1.12E-09 9.00E-10 7.80E-10 8.24E-09 8.33E-09 8.40E-09 7.76E-09 6.84E-09 2.20E-10 -4.70E-10 4.20E-10 4.10E-10 1.18E-09 5.65E-09 5.80E-09 5.67E-09 5.17E-09 5.95E-09 -7.10E-10 0.00E+00 2.20E-10 5.10E-10 6.40E-10 1.08E-08 1.11E-08 1.30E-08 1.35E-08 1.51E-08 1.33E-09 1.30E-09 1.39E-09 1.29E-09 5.10E-10 6.21E-09 6.83E-09 8.35E-09 8.93E-09 9.64E-09 5.10E-09 4.83E-09 5.38E-09 6.25E-09 6.30E-09 6.14E-09 6.27E-09 6.19E-09 6.17E-09 6.04E-09 -8.70E-10 -9.30E-10 -8.90E-10 -1.01E-09 -9.00E-10 3.49E-09 3.79E-09 4.20E-09 3.92E-09 4.11E-09 3.35E-09 3.56E-09 3.35E-09 3.16E-09 2.89E-09 1.27E-08 1.35E-08 1.34E-08 1.26E-08 1.20E-08 -5.70E-09 -5.96E-09 -5.00E-09 -4.73E-09 -3.81E-09 4.54E-09 4.47E-09 1.68E-08 -7.71E-09 -6.50E-08 PASS 6.50E-08 PASS 4.81E-09 4.45E-09 1.70E-08 -7.39E-09 -6.50E-08 PASS 6.50E-08 PASS 5.67E-09 5.23E-09 2.00E-08 -8.66E-09 -6.50E-08 PASS 6.50E-08 PASS 6.10E-09 5.42E-09 2.10E-08 -8.77E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 264 6.44E-09 6.21E-09 2.35E-08 -1.06E-08 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.127. Plot of Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 265 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.127. Raw data for Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status Total Dose (krad(Si)) 0 10 20 30 50 3.11E-09 6.17E-09 6.92E-09 6.00E-09 6.76E-09 -7.80E-10 -1.50E-10 8.20E-10 1.35E-09 1.99E-09 3.07E-09 4.37E-09 5.09E-09 5.18E-09 5.43E-09 1.87E-09 2.15E-09 2.27E-09 2.37E-09 3.49E-09 -2.10E-10 6.00E-10 1.14E-09 9.70E-10 1.79E-09 -1.91E-09 -2.09E-09 -2.89E-09 -3.02E-09 -2.30E-09 1.93E-09 1.99E-09 1.34E-09 2.03E-09 1.81E-09 8.90E-10 1.20E-10 -2.80E-10 -5.50E-10 -7.00E-10 -4.38E-09 -4.60E-09 -5.38E-09 -5.27E-09 -5.27E-09 6.40E-10 1.01E-09 8.80E-10 9.00E-10 8.90E-10 1.16E-08 1.14E-08 9.52E-09 9.58E-09 9.62E-09 2.95E-09 3.18E-09 3.07E-09 3.15E-09 3.02E-09 1.41E-09 2.63E-09 3.25E-09 3.17E-09 3.89E-09 1.82E-09 2.63E-09 2.65E-09 2.28E-09 2.17E-09 6.41E-09 9.84E-09 1.05E-08 9.43E-09 9.83E-09 -3.58E-09 -4.58E-09 -4.03E-09 -3.08E-09 -2.05E-09 -5.66E-10 2.56E-09 6.45E-09 -7.58E-09 -6.50E-08 PASS 6.50E-08 PASS -7.14E-10 2.64E-09 6.54E-09 -7.97E-09 -6.50E-08 PASS 6.50E-08 PASS -1.27E-09 2.83E-09 6.48E-09 -9.01E-09 -6.50E-08 PASS 6.50E-08 PASS -1.18E-09 2.96E-09 6.95E-09 -9.31E-09 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 266 -1.11E-09 2.80E-09 6.57E-09 -8.80E-09 -6.50E-08 PASS 6.50E-08 PASS Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 8.00E-08 6.00E-08 4.00E-08 2.00E-08 0.00E+00 -2.00E-08 -4.00E-08 -6.00E-08 -8.00E-08 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.128. Plot of Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 267 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.128. Raw data for Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -5.07E-09 7.60E-10 6.28E-09 -5.56E-09 -7.93E-09 3.80E-10 -3.34E-09 -2.95E-08 2.30E-10 4.17E-09 -3.86E-09 1.94E-09 Total 10 -2.80E-09 8.40E-10 6.53E-09 -5.72E-09 -8.27E-09 9.20E-10 -3.31E-09 -2.98E-08 1.70E-10 3.99E-09 -3.93E-09 1.90E-09 Dose (krad(Si)) 20 30 -1.42E-09 -2.07E-09 8.00E-10 2.00E-11 7.22E-09 6.93E-09 -5.61E-09 -5.60E-09 -8.46E-09 -1.01E-08 1.78E-09 1.29E-09 -3.24E-09 -4.33E-09 -3.05E-08 -3.00E-08 4.60E-10 1.40E-10 4.38E-09 5.05E-09 -3.80E-09 -3.87E-09 1.87E-09 1.88E-09 50 -3.60E-10 4.40E-10 7.54E-09 -6.78E-09 -9.70E-09 1.55E-09 -3.72E-09 -2.88E-08 7.50E-10 4.78E-09 -3.96E-09 1.83E-09 -2.30E-09 -1.88E-09 -1.49E-09 -2.17E-09 -1.77E-09 5.77E-09 5.80E-09 6.06E-09 6.37E-09 6.74E-09 1.35E-08 1.40E-08 1.51E-08 1.53E-08 1.67E-08 -1.81E-08 -1.78E-08 -1.81E-08 -1.96E-08 -2.02E-08 -5.62E-09 1.36E-08 3.18E-08 -4.30E-08 -6.50E-08 PASS 6.50E-08 PASS -5.61E-09 1.38E-08 3.22E-08 -4.34E-08 -6.50E-08 PASS 6.50E-08 PASS -5.41E-09 1.43E-08 3.37E-08 -4.45E-08 -6.50E-08 PASS 6.50E-08 PASS -5.58E-09 1.41E-08 3.30E-08 -4.42E-08 -6.50E-08 PASS 6.50E-08 PASS An ISO 9001:2008 and DSCC Certified Company 268 -5.08E-09 1.36E-08 3.21E-08 -4.23E-08 -6.50E-08 PASS 6.50E-08 PASS +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.129. Plot of +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 269 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.129. Raw data for +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS5 1 5V (A) Total Dose (krad(Si)) @ VS=+5V, VCM=5V Device 0 10 20 30 50 284 3.47E-07 3.70E-07 3.92E-07 4.12E-07 4.41E-07 303 3.41E-07 3.59E-07 3.71E-07 3.86E-07 4.04E-07 314 3.48E-07 3.71E-07 3.83E-07 3.99E-07 4.17E-07 331 3.48E-07 3.83E-07 3.80E-07 3.93E-07 4.15E-07 368 3.38E-07 3.53E-07 3.67E-07 3.83E-07 4.05E-07 404 3.53E-07 3.72E-07 3.88E-07 4.03E-07 4.27E-07 445 3.42E-07 3.63E-07 3.77E-07 3.92E-07 4.17E-07 474 3.41E-07 3.59E-07 3.74E-07 3.88E-07 4.14E-07 500 3.67E-07 3.86E-07 4.01E-07 4.17E-07 4.46E-07 518 3.46E-07 3.65E-07 3.82E-07 3.96E-07 4.19E-07 524 3.51E-07 3.53E-07 3.53E-07 3.53E-07 3.51E-07 558 3.54E-07 3.53E-07 3.54E-07 3.53E-07 3.55E-07 Biased Statistics Average Biased 3.44E-07 3.67E-07 3.79E-07 3.94E-07 4.16E-07 Std Dev Biased 4.79E-09 1.17E-08 1.00E-08 1.16E-08 1.48E-08 Ps90%/90% (+KTL) Biased 3.58E-07 3.99E-07 4.06E-07 4.26E-07 4.57E-07 Ps90%/90% (-KTL) Biased 3.31E-07 3.35E-07 3.51E-07 3.63E-07 3.76E-07 Un-Biased Statistics Average Un-Biased 3.50E-07 3.69E-07 3.84E-07 3.99E-07 4.25E-07 Std Dev Un-Biased 1.07E-08 1.07E-08 1.08E-08 1.15E-08 1.27E-08 Ps90%/90% (+KTL) Un-Biased 3.79E-07 3.98E-07 4.14E-07 4.31E-07 4.59E-07 Ps90%/90% (-KTL) Un-Biased 3.21E-07 3.40E-07 3.55E-07 3.68E-07 3.90E-07 Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 270 +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.130. Plot of +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 271 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.130. Raw data for +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS5 2 5V (A) Total Dose (krad(Si)) @ VS=+5V, VCM=5V Device 0 10 20 30 50 284 3.49E-07 3.77E-07 3.98E-07 4.17E-07 4.47E-07 303 3.48E-07 3.68E-07 3.81E-07 3.94E-07 4.12E-07 314 3.57E-07 3.77E-07 3.88E-07 4.06E-07 4.23E-07 331 3.46E-07 3.78E-07 3.76E-07 3.89E-07 4.09E-07 368 3.47E-07 3.64E-07 3.79E-07 3.88E-07 4.07E-07 404 3.56E-07 3.76E-07 3.93E-07 4.06E-07 4.29E-07 445 3.58E-07 3.79E-07 3.96E-07 4.12E-07 4.38E-07 474 3.48E-07 3.70E-07 3.85E-07 4.00E-07 4.25E-07 500 3.52E-07 3.74E-07 3.91E-07 4.06E-07 4.35E-07 518 3.47E-07 3.66E-07 3.84E-07 3.97E-07 4.22E-07 524 3.57E-07 3.59E-07 3.61E-07 3.59E-07 3.58E-07 558 3.49E-07 3.47E-07 3.49E-07 3.48E-07 3.48E-07 Biased Statistics Average Biased 3.49E-07 3.73E-07 3.84E-07 3.99E-07 4.20E-07 Std Dev Biased 4.23E-09 6.37E-09 8.95E-09 1.25E-08 1.66E-08 Ps90%/90% (+KTL) Biased 3.61E-07 3.90E-07 4.09E-07 4.33E-07 4.65E-07 Ps90%/90% (-KTL) Biased 3.38E-07 3.55E-07 3.60E-07 3.65E-07 3.74E-07 Un-Biased Statistics Average Un-Biased 3.52E-07 3.73E-07 3.90E-07 4.04E-07 4.30E-07 Std Dev Un-Biased 4.78E-09 5.29E-09 5.39E-09 5.72E-09 6.56E-09 Ps90%/90% (+KTL) Un-Biased 3.65E-07 3.88E-07 4.05E-07 4.20E-07 4.48E-07 Ps90%/90% (-KTL) Un-Biased 3.39E-07 3.59E-07 3.75E-07 3.88E-07 4.12E-07 Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 272 +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.131. Plot of +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 273 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.131. Raw data for +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS5 3 5V (A) Total Dose (krad(Si)) @ VS=+5V, VCM=5V Device 0 10 20 30 50 284 3.54E-07 3.80E-07 3.98E-07 4.19E-07 4.45E-07 303 3.52E-07 3.72E-07 3.84E-07 3.99E-07 4.19E-07 314 3.51E-07 3.73E-07 3.83E-07 3.98E-07 4.18E-07 331 3.43E-07 3.77E-07 3.74E-07 3.87E-07 4.07E-07 368 3.48E-07 3.66E-07 3.79E-07 3.90E-07 4.13E-07 404 3.61E-07 3.80E-07 3.94E-07 4.10E-07 4.33E-07 445 3.40E-07 3.63E-07 3.76E-07 3.92E-07 4.19E-07 474 3.48E-07 3.67E-07 3.82E-07 3.96E-07 4.22E-07 500 3.50E-07 3.71E-07 3.89E-07 4.03E-07 4.32E-07 518 3.44E-07 3.64E-07 3.80E-07 3.94E-07 4.17E-07 524 3.56E-07 3.57E-07 3.58E-07 3.56E-07 3.55E-07 558 3.55E-07 3.56E-07 3.57E-07 3.55E-07 3.56E-07 Biased Statistics Average Biased 3.50E-07 3.73E-07 3.84E-07 3.98E-07 4.20E-07 Std Dev Biased 4.30E-09 5.24E-09 8.65E-09 1.24E-08 1.46E-08 Ps90%/90% (+KTL) Biased 3.61E-07 3.88E-07 4.07E-07 4.32E-07 4.60E-07 Ps90%/90% (-KTL) Biased 3.38E-07 3.59E-07 3.60E-07 3.64E-07 3.80E-07 Un-Biased Statistics Average Un-Biased 3.49E-07 3.69E-07 3.84E-07 3.99E-07 4.24E-07 Std Dev Un-Biased 7.70E-09 6.83E-09 7.24E-09 7.37E-09 7.26E-09 Ps90%/90% (+KTL) Un-Biased 3.70E-07 3.88E-07 4.04E-07 4.19E-07 4.44E-07 Ps90%/90% (-KTL) Un-Biased 3.28E-07 3.50E-07 3.64E-07 3.79E-07 4.05E-07 Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 274 +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.132. Plot of +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 275 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.132. Raw data for +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Input Bias Current BIAS5 4 5V (A) Total Dose (krad(Si)) @ VS=+5V, VCM=5V Device 0 10 20 30 50 284 3.45E-07 3.70E-07 3.88E-07 4.06E-07 4.37E-07 303 3.43E-07 3.63E-07 3.73E-07 3.86E-07 4.05E-07 314 3.57E-07 3.79E-07 3.90E-07 4.06E-07 4.24E-07 331 3.53E-07 3.87E-07 3.86E-07 3.97E-07 4.18E-07 368 3.37E-07 3.52E-07 3.67E-07 3.79E-07 4.04E-07 404 3.43E-07 3.62E-07 3.79E-07 3.95E-07 4.19E-07 445 3.42E-07 3.63E-07 3.78E-07 3.92E-07 4.18E-07 474 3.41E-07 3.59E-07 3.73E-07 3.87E-07 4.14E-07 500 3.47E-07 3.66E-07 3.82E-07 3.96E-07 4.24E-07 518 3.47E-07 3.67E-07 3.84E-07 3.99E-07 4.22E-07 524 3.57E-07 3.60E-07 3.58E-07 3.58E-07 3.57E-07 558 3.41E-07 3.41E-07 3.42E-07 3.41E-07 3.41E-07 Biased Statistics Average Biased 3.47E-07 3.70E-07 3.81E-07 3.95E-07 4.18E-07 Std Dev Biased 8.13E-09 1.34E-08 1.01E-08 1.22E-08 1.37E-08 Ps90%/90% (+KTL) Biased 3.70E-07 4.07E-07 4.08E-07 4.29E-07 4.55E-07 Ps90%/90% (-KTL) Biased 3.25E-07 3.33E-07 3.53E-07 3.61E-07 3.80E-07 Un-Biased Statistics Average Un-Biased 3.44E-07 3.63E-07 3.79E-07 3.94E-07 4.19E-07 Std Dev Un-Biased 2.77E-09 3.21E-09 4.13E-09 4.56E-09 3.82E-09 Ps90%/90% (+KTL) Un-Biased 3.52E-07 3.72E-07 3.91E-07 4.06E-07 4.30E-07 Ps90%/90% (-KTL) Un-Biased 3.37E-07 3.54E-07 3.68E-07 3.81E-07 4.09E-07 Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 276 -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.133. Plot of -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 277 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.133. Raw data for -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS5 1 5V (A) Total Dose (krad(Si)) @ VS=+5V, VCM=5V Device 0 10 20 30 50 284 3.57E-07 3.78E-07 3.97E-07 4.17E-07 4.46E-07 303 3.50E-07 3.67E-07 3.82E-07 3.95E-07 4.15E-07 314 3.51E-07 3.72E-07 3.86E-07 3.98E-07 4.18E-07 331 3.50E-07 3.84E-07 3.81E-07 3.92E-07 4.14E-07 368 3.43E-07 3.62E-07 3.75E-07 3.90E-07 4.14E-07 404 3.46E-07 3.65E-07 3.80E-07 3.95E-07 4.21E-07 445 3.41E-07 3.62E-07 3.78E-07 3.92E-07 4.17E-07 474 3.45E-07 3.64E-07 3.78E-07 3.92E-07 4.19E-07 500 3.55E-07 3.74E-07 3.89E-07 4.03E-07 4.32E-07 518 3.44E-07 3.63E-07 3.81E-07 3.94E-07 4.16E-07 524 3.51E-07 3.53E-07 3.52E-07 3.51E-07 3.50E-07 558 3.52E-07 3.52E-07 3.53E-07 3.52E-07 3.52E-07 Biased Statistics Average Biased 3.50E-07 3.72E-07 3.84E-07 3.98E-07 4.21E-07 Std Dev Biased 4.75E-09 8.59E-09 8.25E-09 1.09E-08 1.37E-08 Ps90%/90% (+KTL) Biased 3.63E-07 3.96E-07 4.07E-07 4.28E-07 4.59E-07 Ps90%/90% (-KTL) Biased 3.37E-07 3.49E-07 3.62E-07 3.68E-07 3.84E-07 Un-Biased Statistics Average Un-Biased 3.46E-07 3.65E-07 3.81E-07 3.95E-07 4.21E-07 Std Dev Un-Biased 5.07E-09 4.63E-09 4.59E-09 4.60E-09 6.58E-09 Ps90%/90% (+KTL) Un-Biased 3.60E-07 3.78E-07 3.94E-07 4.08E-07 4.39E-07 Ps90%/90% (-KTL) Un-Biased 3.32E-07 3.53E-07 3.69E-07 3.83E-07 4.03E-07 Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 278 -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.134. Plot of -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 279 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.134. Raw data for -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS5 2 5V (A) Total Dose (krad(Si)) @ VS=+5V, VCM=5V Device 0 10 20 30 50 284 3.49E-07 3.73E-07 3.93E-07 4.13E-07 4.41E-07 303 3.47E-07 3.71E-07 3.82E-07 3.96E-07 4.16E-07 314 3.51E-07 3.72E-07 3.82E-07 3.98E-07 4.17E-07 331 3.46E-07 3.80E-07 3.77E-07 3.89E-07 4.11E-07 368 3.42E-07 3.59E-07 3.73E-07 3.84E-07 4.03E-07 404 3.57E-07 3.77E-07 3.93E-07 4.07E-07 4.28E-07 445 3.48E-07 3.70E-07 3.84E-07 3.99E-07 4.25E-07 474 3.46E-07 3.69E-07 3.84E-07 3.99E-07 4.24E-07 500 3.46E-07 3.68E-07 3.84E-07 3.99E-07 4.28E-07 518 3.42E-07 3.62E-07 3.80E-07 3.94E-07 4.18E-07 524 3.54E-07 3.55E-07 3.57E-07 3.55E-07 3.54E-07 558 3.51E-07 3.50E-07 3.51E-07 3.50E-07 3.50E-07 Biased Statistics Average Biased 3.47E-07 3.71E-07 3.81E-07 3.96E-07 4.17E-07 Std Dev Biased 3.12E-09 7.57E-09 7.51E-09 1.10E-08 1.41E-08 Ps90%/90% (+KTL) Biased 3.56E-07 3.92E-07 4.02E-07 4.26E-07 4.56E-07 Ps90%/90% (-KTL) Biased 3.38E-07 3.50E-07 3.61E-07 3.66E-07 3.79E-07 Un-Biased Statistics Average Un-Biased 3.48E-07 3.69E-07 3.85E-07 4.00E-07 4.25E-07 Std Dev Un-Biased 5.68E-09 5.06E-09 4.84E-09 4.76E-09 4.28E-09 Ps90%/90% (+KTL) Un-Biased 3.64E-07 3.83E-07 3.99E-07 4.13E-07 4.36E-07 Ps90%/90% (-KTL) Un-Biased 3.33E-07 3.56E-07 3.72E-07 3.87E-07 4.13E-07 Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 280 -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.135. Plot of -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 281 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.135. Raw data for -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS5 3 5V (A) Total Dose (krad(Si)) @ VS=+5V, VCM=5V Device 0 10 20 30 50 284 3.53E-07 3.75E-07 3.94E-07 4.12E-07 4.42E-07 303 3.56E-07 3.73E-07 3.84E-07 3.98E-07 4.18E-07 314 3.50E-07 3.69E-07 3.79E-07 3.94E-07 4.15E-07 331 3.44E-07 3.76E-07 3.74E-07 3.86E-07 4.07E-07 368 3.50E-07 3.67E-07 3.80E-07 3.92E-07 4.11E-07 404 3.64E-07 3.82E-07 4.00E-07 4.13E-07 4.36E-07 445 3.39E-07 3.61E-07 3.75E-07 3.91E-07 4.18E-07 474 3.49E-07 3.69E-07 3.83E-07 3.98E-07 4.24E-07 500 3.56E-07 3.76E-07 3.94E-07 4.10E-07 4.39E-07 518 3.45E-07 3.63E-07 3.81E-07 3.94E-07 4.21E-07 524 3.47E-07 3.50E-07 3.49E-07 3.49E-07 3.46E-07 558 3.54E-07 3.54E-07 3.55E-07 3.53E-07 3.53E-07 Biased Statistics Average Biased 3.51E-07 3.72E-07 3.82E-07 3.96E-07 4.19E-07 Std Dev Biased 4.43E-09 3.78E-09 7.30E-09 9.85E-09 1.37E-08 Ps90%/90% (+KTL) Biased 3.63E-07 3.82E-07 4.02E-07 4.23E-07 4.56E-07 Ps90%/90% (-KTL) Biased 3.38E-07 3.61E-07 3.62E-07 3.69E-07 3.81E-07 Un-Biased Statistics Average Un-Biased 3.50E-07 3.70E-07 3.87E-07 4.01E-07 4.28E-07 Std Dev Un-Biased 9.62E-09 8.77E-09 9.92E-09 9.93E-09 9.47E-09 Ps90%/90% (+KTL) Un-Biased 3.77E-07 3.94E-07 4.14E-07 4.29E-07 4.54E-07 Ps90%/90% (-KTL) Un-Biased 3.24E-07 3.46E-07 3.59E-07 3.74E-07 4.02E-07 Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 282 -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-06 8.00E-07 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 -8.00E-07 -1.00E-06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.136. Plot of -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 283 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.136. Raw data for -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Input Bias Current BIAS5 4 5V (A) Total Dose (krad(Si)) @ VS=+5V, VCM=5V Device 0 10 20 30 50 284 3.53E-07 3.73E-07 3.90E-07 4.10E-07 4.38E-07 303 3.44E-07 3.62E-07 3.73E-07 3.87E-07 4.06E-07 314 3.55E-07 3.74E-07 3.85E-07 3.98E-07 4.19E-07 331 3.63E-07 3.94E-07 3.94E-07 4.04E-07 4.26E-07 368 3.43E-07 3.62E-07 3.77E-07 3.91E-07 4.15E-07 404 3.44E-07 3.63E-07 3.80E-07 3.95E-07 4.19E-07 445 3.46E-07 3.67E-07 3.82E-07 3.97E-07 4.23E-07 474 3.72E-07 3.91E-07 4.05E-07 4.19E-07 4.44E-07 500 3.50E-07 3.67E-07 3.81E-07 3.97E-07 4.24E-07 518 3.44E-07 3.65E-07 3.83E-07 3.95E-07 4.20E-07 524 3.63E-07 3.64E-07 3.65E-07 3.64E-07 3.63E-07 558 3.39E-07 3.40E-07 3.41E-07 3.42E-07 3.41E-07 Biased Statistics Average Biased 3.51E-07 3.73E-07 3.84E-07 3.98E-07 4.21E-07 Std Dev Biased 7.94E-09 1.31E-08 8.90E-09 9.48E-09 1.21E-08 Ps90%/90% (+KTL) Biased 3.73E-07 4.09E-07 4.08E-07 4.24E-07 4.54E-07 Ps90%/90% (-KTL) Biased 3.30E-07 3.37E-07 3.59E-07 3.72E-07 3.88E-07 Un-Biased Statistics Average Un-Biased 3.51E-07 3.71E-07 3.86E-07 4.01E-07 4.26E-07 Std Dev Un-Biased 1.19E-08 1.14E-08 1.07E-08 1.02E-08 1.04E-08 Ps90%/90% (+KTL) Un-Biased 3.84E-07 4.02E-07 4.16E-07 4.29E-07 4.55E-07 Ps90%/90% (-KTL) Un-Biased 3.19E-07 3.39E-07 3.57E-07 3.73E-07 3.98E-07 Specification MIN -6.50E-07 -7.00E-07 -7.50E-07 -7.50E-07 -8.00E-07 Status PASS PASS PASS PASS PASS Specification MAX 6.50E-07 7.00E-07 7.50E-07 7.50E-07 8.00E-07 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 284 Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.137. Plot of Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 285 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.137. Raw data for Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High4 1 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=0mA Device 0 10 20 30 50 284 5.28E-03 5.24E-03 5.39E-03 5.20E-03 5.35E-03 303 5.16E-03 5.14E-03 5.42E-03 5.29E-03 5.32E-03 314 5.24E-03 5.09E-03 5.19E-03 5.25E-03 5.30E-03 331 5.30E-03 5.34E-03 5.35E-03 5.47E-03 5.39E-03 368 5.09E-03 5.06E-03 4.98E-03 5.04E-03 5.15E-03 404 4.99E-03 5.04E-03 5.12E-03 5.03E-03 5.20E-03 445 5.01E-03 5.02E-03 5.14E-03 5.16E-03 5.10E-03 474 5.14E-03 5.33E-03 5.12E-03 5.45E-03 5.44E-03 500 5.30E-03 5.31E-03 5.37E-03 5.41E-03 5.59E-03 518 5.14E-03 5.19E-03 5.29E-03 5.20E-03 5.34E-03 524 5.31E-03 5.29E-03 5.34E-03 5.36E-03 5.42E-03 558 5.11E-03 5.08E-03 5.29E-03 5.16E-03 5.10E-03 Biased Statistics Average Biased 5.21E-03 5.17E-03 5.27E-03 5.25E-03 5.30E-03 Std Dev Biased 8.76E-05 1.15E-04 1.83E-04 1.55E-04 9.15E-05 Ps90%/90% (+KTL) Biased 5.45E-03 5.49E-03 5.77E-03 5.68E-03 5.55E-03 Ps90%/90% (-KTL) Biased 4.97E-03 4.86E-03 4.76E-03 4.82E-03 5.05E-03 Un-Biased Statistics Average Un-Biased 5.12E-03 5.18E-03 5.21E-03 5.25E-03 5.33E-03 Std Dev Un-Biased 1.25E-04 1.45E-04 1.15E-04 1.76E-04 1.93E-04 Ps90%/90% (+KTL) Un-Biased 5.46E-03 5.58E-03 5.52E-03 5.73E-03 5.86E-03 Ps90%/90% (-KTL) Un-Biased 4.77E-03 4.78E-03 4.89E-03 4.77E-03 4.80E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 286 Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.138. Plot of Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 287 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.138. Raw data for Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High4 2 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=0mA Device 0 10 20 30 50 284 5.28E-03 5.19E-03 5.37E-03 5.30E-03 5.52E-03 303 5.26E-03 5.14E-03 5.30E-03 5.37E-03 5.30E-03 314 5.14E-03 5.21E-03 5.29E-03 5.26E-03 5.30E-03 331 5.41E-03 5.38E-03 5.44E-03 5.35E-03 5.49E-03 368 5.36E-03 5.21E-03 5.32E-03 5.28E-03 5.30E-03 404 5.33E-03 5.08E-03 5.22E-03 5.30E-03 5.32E-03 445 5.13E-03 5.31E-03 5.29E-03 5.41E-03 5.39E-03 474 5.31E-03 5.28E-03 5.25E-03 5.47E-03 5.47E-03 500 5.28E-03 5.26E-03 5.39E-03 5.50E-03 5.54E-03 518 5.26E-03 5.31E-03 5.34E-03 5.40E-03 5.39E-03 524 5.26E-03 5.24E-03 5.20E-03 5.36E-03 5.28E-03 558 5.16E-03 5.28E-03 5.34E-03 5.23E-03 5.34E-03 Biased Statistics Average Biased 5.29E-03 5.23E-03 5.34E-03 5.31E-03 5.38E-03 Std Dev Biased 1.03E-04 9.07E-05 6.19E-05 4.66E-05 1.13E-04 Ps90%/90% (+KTL) Biased 5.57E-03 5.47E-03 5.51E-03 5.44E-03 5.69E-03 Ps90%/90% (-KTL) Biased 5.01E-03 4.98E-03 5.17E-03 5.18E-03 5.07E-03 Un-Biased Statistics Average Un-Biased 5.26E-03 5.25E-03 5.30E-03 5.42E-03 5.42E-03 Std Dev Un-Biased 7.85E-05 9.63E-05 6.83E-05 7.70E-05 8.47E-05 Ps90%/90% (+KTL) Un-Biased 5.48E-03 5.51E-03 5.49E-03 5.63E-03 5.65E-03 Ps90%/90% (-KTL) Un-Biased 5.05E-03 4.98E-03 5.11E-03 5.20E-03 5.19E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 288 Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.139. Plot of Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 289 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.139. Raw data for Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High4 3 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=0mA Device 0 10 20 30 50 284 5.21E-03 5.21E-03 5.27E-03 5.27E-03 5.28E-03 303 5.23E-03 5.26E-03 5.19E-03 5.25E-03 5.42E-03 314 5.04E-03 5.13E-03 5.03E-03 5.18E-03 5.15E-03 331 5.33E-03 5.23E-03 5.40E-03 5.41E-03 5.50E-03 368 5.31E-03 5.16E-03 5.29E-03 5.31E-03 5.27E-03 404 5.14E-03 5.06E-03 5.29E-03 5.26E-03 5.28E-03 445 5.35E-03 5.23E-03 5.34E-03 5.55E-03 5.44E-03 474 5.33E-03 5.24E-03 5.29E-03 5.47E-03 5.42E-03 500 5.28E-03 5.29E-03 5.40E-03 5.45E-03 5.54E-03 518 5.23E-03 5.19E-03 5.35E-03 5.40E-03 5.42E-03 524 5.30E-03 5.33E-03 5.39E-03 5.25E-03 5.40E-03 558 5.13E-03 5.26E-03 5.20E-03 5.26E-03 5.32E-03 Biased Statistics Average Biased 5.22E-03 5.20E-03 5.24E-03 5.28E-03 5.32E-03 Std Dev Biased 1.15E-04 5.26E-05 1.37E-04 8.47E-05 1.37E-04 Ps90%/90% (+KTL) Biased 5.54E-03 5.34E-03 5.61E-03 5.52E-03 5.70E-03 Ps90%/90% (-KTL) Biased 4.91E-03 5.05E-03 4.86E-03 5.05E-03 4.95E-03 Un-Biased Statistics Average Un-Biased 5.27E-03 5.20E-03 5.33E-03 5.43E-03 5.42E-03 Std Dev Un-Biased 8.44E-05 8.70E-05 4.62E-05 1.07E-04 9.27E-05 Ps90%/90% (+KTL) Un-Biased 5.50E-03 5.44E-03 5.46E-03 5.72E-03 5.67E-03 Ps90%/90% (-KTL) Un-Biased 5.03E-03 4.96E-03 5.21E-03 5.13E-03 5.17E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 290 Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.140. Plot of Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 291 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.140. Raw data for Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High4 4 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=0mA Device 0 10 20 30 50 284 5.28E-03 5.40E-03 5.34E-03 5.27E-03 5.30E-03 303 5.26E-03 5.24E-03 5.44E-03 5.30E-03 5.52E-03 314 5.28E-03 5.23E-03 5.14E-03 5.28E-03 5.44E-03 331 5.40E-03 5.21E-03 5.37E-03 5.41E-03 5.50E-03 368 5.18E-03 5.04E-03 5.27E-03 5.09E-03 5.22E-03 404 5.11E-03 4.99E-03 5.25E-03 5.18E-03 5.28E-03 445 5.30E-03 5.02E-03 5.24E-03 5.15E-03 5.27E-03 474 5.31E-03 5.40E-03 5.39E-03 5.40E-03 5.45E-03 500 5.24E-03 5.34E-03 5.40E-03 5.38E-03 5.50E-03 518 5.23E-03 5.40E-03 5.27E-03 5.41E-03 5.52E-03 524 5.23E-03 5.38E-03 5.27E-03 5.47E-03 5.57E-03 558 5.23E-03 5.21E-03 5.17E-03 5.20E-03 5.40E-03 Biased Statistics Average Biased 5.28E-03 5.22E-03 5.31E-03 5.27E-03 5.40E-03 Std Dev Biased 7.87E-05 1.28E-04 1.14E-04 1.15E-04 1.31E-04 Ps90%/90% (+KTL) Biased 5.50E-03 5.57E-03 5.62E-03 5.59E-03 5.75E-03 Ps90%/90% (-KTL) Biased 5.06E-03 4.87E-03 5.00E-03 4.95E-03 5.04E-03 Un-Biased Statistics Average Un-Biased 5.24E-03 5.23E-03 5.31E-03 5.30E-03 5.40E-03 Std Dev Un-Biased 7.98E-05 2.07E-04 7.84E-05 1.28E-04 1.21E-04 Ps90%/90% (+KTL) Un-Biased 5.46E-03 5.80E-03 5.53E-03 5.65E-03 5.73E-03 Ps90%/90% (-KTL) Un-Biased 5.02E-03 4.66E-03 5.09E-03 4.95E-03 5.07E-03 Specification MAX 1.00E-02 2.00E-02 2.00E-02 2.00E-02 2.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 292 Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.141. Plot of Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 293 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.141. Raw data for Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High5 1 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=1mA Device 0 10 20 30 50 284 7.24E-02 7.36E-02 7.40E-02 7.42E-02 7.49E-02 303 7.33E-02 7.39E-02 7.48E-02 7.53E-02 7.57E-02 314 7.19E-02 7.28E-02 7.34E-02 7.37E-02 7.44E-02 331 7.40E-02 7.54E-02 7.54E-02 7.56E-02 7.63E-02 368 7.15E-02 7.21E-02 7.28E-02 7.31E-02 7.36E-02 404 6.93E-02 6.93E-02 6.97E-02 6.99E-02 7.02E-02 445 7.00E-02 7.02E-02 7.03E-02 7.08E-02 7.10E-02 474 7.34E-02 7.37E-02 7.40E-02 7.42E-02 7.43E-02 500 7.40E-02 7.41E-02 7.43E-02 7.48E-02 7.50E-02 518 7.30E-02 7.32E-02 7.37E-02 7.38E-02 7.42E-02 524 7.23E-02 7.20E-02 7.23E-02 7.23E-02 7.24E-02 558 7.06E-02 7.03E-02 7.07E-02 7.05E-02 7.06E-02 Biased Statistics Average Biased 7.26E-02 7.36E-02 7.41E-02 7.44E-02 7.50E-02 Std Dev Biased 1.04E-03 1.26E-03 1.02E-03 1.07E-03 1.08E-03 Ps90%/90% (+KTL) Biased 7.55E-02 7.70E-02 7.69E-02 7.73E-02 7.79E-02 Ps90%/90% (-KTL) Biased 6.98E-02 7.01E-02 7.13E-02 7.15E-02 7.20E-02 Un-Biased Statistics Average Un-Biased 7.19E-02 7.21E-02 7.24E-02 7.27E-02 7.30E-02 Std Dev Un-Biased 2.15E-03 2.20E-03 2.19E-03 2.20E-03 2.19E-03 Ps90%/90% (+KTL) Un-Biased 7.78E-02 7.81E-02 7.84E-02 7.87E-02 7.90E-02 Ps90%/90% (-KTL) Un-Biased 6.60E-02 6.61E-02 6.64E-02 6.67E-02 6.70E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 294 Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.142. Plot of Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 295 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.142. Raw data for Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High5 2 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=1mA Device 0 10 20 30 50 284 7.17E-02 7.27E-02 7.30E-02 7.34E-02 7.41E-02 303 7.27E-02 7.34E-02 7.39E-02 7.43E-02 7.50E-02 314 6.87E-02 6.95E-02 7.01E-02 7.03E-02 7.11E-02 331 7.41E-02 7.54E-02 7.56E-02 7.60E-02 7.63E-02 368 7.12E-02 7.18E-02 7.23E-02 7.29E-02 7.34E-02 404 7.02E-02 7.04E-02 7.07E-02 7.09E-02 7.11E-02 445 7.24E-02 7.24E-02 7.28E-02 7.32E-02 7.36E-02 474 7.20E-02 7.21E-02 7.24E-02 7.28E-02 7.30E-02 500 7.32E-02 7.32E-02 7.36E-02 7.36E-02 7.41E-02 518 7.28E-02 7.31E-02 7.33E-02 7.37E-02 7.41E-02 524 7.19E-02 7.17E-02 7.18E-02 7.19E-02 7.19E-02 558 6.90E-02 6.87E-02 6.90E-02 6.88E-02 6.89E-02 Biased Statistics Average Biased 7.17E-02 7.25E-02 7.30E-02 7.34E-02 7.40E-02 Std Dev Biased 1.98E-03 2.16E-03 2.03E-03 2.08E-03 1.97E-03 Ps90%/90% (+KTL) Biased 7.71E-02 7.85E-02 7.86E-02 7.91E-02 7.94E-02 Ps90%/90% (-KTL) Biased 6.62E-02 6.66E-02 6.74E-02 6.77E-02 6.86E-02 Un-Biased Statistics Average Un-Biased 7.21E-02 7.22E-02 7.26E-02 7.28E-02 7.32E-02 Std Dev Un-Biased 1.15E-03 1.12E-03 1.15E-03 1.14E-03 1.24E-03 Ps90%/90% (+KTL) Un-Biased 7.53E-02 7.53E-02 7.57E-02 7.60E-02 7.66E-02 Ps90%/90% (-KTL) Un-Biased 6.89E-02 6.92E-02 6.94E-02 6.97E-02 6.98E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 296 Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.143. Plot of Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 297 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.143. Raw data for Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High5 3 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=1mA Device 0 10 20 30 50 284 7.18E-02 7.29E-02 7.33E-02 7.35E-02 7.43E-02 303 7.22E-02 7.31E-02 7.35E-02 7.41E-02 7.47E-02 314 6.90E-02 6.97E-02 7.02E-02 7.08E-02 7.11E-02 331 7.44E-02 7.58E-02 7.59E-02 7.61E-02 7.65E-02 368 7.12E-02 7.20E-02 7.27E-02 7.27E-02 7.34E-02 404 7.02E-02 7.03E-02 7.09E-02 7.10E-02 7.12E-02 445 7.24E-02 7.25E-02 7.26E-02 7.30E-02 7.32E-02 474 7.25E-02 7.26E-02 7.30E-02 7.30E-02 7.36E-02 500 7.29E-02 7.33E-02 7.33E-02 7.38E-02 7.39E-02 518 7.29E-02 7.32E-02 7.36E-02 7.38E-02 7.42E-02 524 7.21E-02 7.19E-02 7.23E-02 7.22E-02 7.22E-02 558 6.88E-02 6.88E-02 6.89E-02 6.88E-02 6.90E-02 Biased Statistics Average Biased 7.17E-02 7.27E-02 7.31E-02 7.34E-02 7.40E-02 Std Dev Biased 1.92E-03 2.18E-03 2.01E-03 1.93E-03 1.99E-03 Ps90%/90% (+KTL) Biased 7.70E-02 7.87E-02 7.86E-02 7.87E-02 7.95E-02 Ps90%/90% (-KTL) Biased 6.64E-02 6.67E-02 6.76E-02 6.81E-02 6.86E-02 Un-Biased Statistics Average Un-Biased 7.22E-02 7.24E-02 7.27E-02 7.29E-02 7.32E-02 Std Dev Un-Biased 1.15E-03 1.21E-03 1.07E-03 1.13E-03 1.18E-03 Ps90%/90% (+KTL) Un-Biased 7.53E-02 7.57E-02 7.56E-02 7.60E-02 7.64E-02 Ps90%/90% (-KTL) Un-Biased 6.90E-02 6.91E-02 6.97E-02 6.98E-02 7.00E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 298 Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.60E-01 1.40E-01 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.144. Plot of Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 299 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.144. Raw data for Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High5 4 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=1mA Device 0 10 20 30 50 284 7.24E-02 7.38E-02 7.37E-02 7.44E-02 7.49E-02 303 7.36E-02 7.44E-02 7.47E-02 7.52E-02 7.59E-02 314 7.23E-02 7.32E-02 7.37E-02 7.41E-02 7.48E-02 331 7.40E-02 7.54E-02 7.55E-02 7.58E-02 7.63E-02 368 7.14E-02 7.21E-02 7.28E-02 7.29E-02 7.36E-02 404 6.91E-02 6.91E-02 6.98E-02 6.98E-02 7.04E-02 445 6.97E-02 6.98E-02 6.98E-02 7.04E-02 7.06E-02 474 7.28E-02 7.29E-02 7.33E-02 7.36E-02 7.38E-02 500 7.41E-02 7.44E-02 7.46E-02 7.48E-02 7.52E-02 518 7.29E-02 7.31E-02 7.34E-02 7.38E-02 7.40E-02 524 7.24E-02 7.24E-02 7.24E-02 7.24E-02 7.24E-02 558 7.01E-02 7.01E-02 7.03E-02 7.01E-02 7.02E-02 Biased Statistics Average Biased 7.27E-02 7.38E-02 7.41E-02 7.45E-02 7.51E-02 Std Dev Biased 1.06E-03 1.21E-03 1.06E-03 1.13E-03 1.07E-03 Ps90%/90% (+KTL) Biased 7.56E-02 7.71E-02 7.70E-02 7.76E-02 7.80E-02 Ps90%/90% (-KTL) Biased 6.98E-02 7.04E-02 7.12E-02 7.14E-02 7.21E-02 Un-Biased Statistics Average Un-Biased 7.17E-02 7.19E-02 7.22E-02 7.25E-02 7.28E-02 Std Dev Un-Biased 2.19E-03 2.28E-03 2.22E-03 2.22E-03 2.18E-03 Ps90%/90% (+KTL) Un-Biased 7.77E-02 7.81E-02 7.82E-02 7.85E-02 7.88E-02 Ps90%/90% (-KTL) Un-Biased 6.57E-02 6.56E-02 6.61E-02 6.64E-02 6.68E-02 Specification MAX 1.50E-01 1.50E-01 1.50E-01 1.50E-01 1.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 300 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.145. Plot of Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 301 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.145. Raw data for Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High6 1 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=2.5mA Device 0 10 20 30 50 284 1.30E-01 1.31E-01 1.31E-01 1.31E-01 1.32E-01 303 1.31E-01 1.31E-01 1.32E-01 1.33E-01 1.33E-01 314 1.29E-01 1.30E-01 1.30E-01 1.31E-01 1.31E-01 331 1.32E-01 1.33E-01 1.33E-01 1.33E-01 1.34E-01 368 1.28E-01 1.28E-01 1.29E-01 1.30E-01 1.30E-01 404 1.25E-01 1.25E-01 1.25E-01 1.26E-01 1.26E-01 445 1.26E-01 1.26E-01 1.27E-01 1.27E-01 1.28E-01 474 1.31E-01 1.31E-01 1.31E-01 1.32E-01 1.32E-01 500 1.31E-01 1.31E-01 1.32E-01 1.32E-01 1.33E-01 518 1.30E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 524 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 558 1.27E-01 1.27E-01 1.27E-01 1.27E-01 1.27E-01 Biased Statistics Average Biased 1.30E-01 1.31E-01 1.31E-01 1.32E-01 1.32E-01 Std Dev Biased 1.36E-03 1.58E-03 1.49E-03 1.45E-03 1.45E-03 Ps90%/90% (+KTL) Biased 1.34E-01 1.35E-01 1.35E-01 1.36E-01 1.36E-01 Ps90%/90% (-KTL) Biased 1.26E-01 1.26E-01 1.27E-01 1.28E-01 1.28E-01 Un-Biased Statistics Average Un-Biased 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.30E-01 Std Dev Un-Biased 2.97E-03 3.09E-03 2.94E-03 2.98E-03 2.97E-03 Ps90%/90% (+KTL) Un-Biased 1.37E-01 1.37E-01 1.37E-01 1.38E-01 1.38E-01 Ps90%/90% (-KTL) Un-Biased 1.21E-01 1.20E-01 1.21E-01 1.21E-01 1.22E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 302 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.146. Plot of Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 303 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.146. Raw data for Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High6 2 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=2.5mA Device 0 10 20 30 50 284 1.29E-01 1.30E-01 1.30E-01 1.31E-01 1.31E-01 303 1.30E-01 1.30E-01 1.31E-01 1.32E-01 1.32E-01 314 1.24E-01 1.25E-01 1.26E-01 1.26E-01 1.27E-01 331 1.32E-01 1.33E-01 1.33E-01 1.34E-01 1.34E-01 368 1.28E-01 1.28E-01 1.29E-01 1.30E-01 1.30E-01 404 1.27E-01 1.27E-01 1.27E-01 1.28E-01 1.28E-01 445 1.30E-01 1.30E-01 1.30E-01 1.31E-01 1.31E-01 474 1.29E-01 1.29E-01 1.29E-01 1.30E-01 1.30E-01 500 1.30E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 518 1.30E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 524 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.29E-01 558 1.25E-01 1.25E-01 1.25E-01 1.25E-01 1.25E-01 Biased Statistics Average Biased 1.28E-01 1.29E-01 1.30E-01 1.30E-01 1.31E-01 Std Dev Biased 2.87E-03 2.98E-03 2.85E-03 2.90E-03 2.85E-03 Ps90%/90% (+KTL) Biased 1.36E-01 1.37E-01 1.38E-01 1.38E-01 1.39E-01 Ps90%/90% (-KTL) Biased 1.21E-01 1.21E-01 1.22E-01 1.22E-01 1.23E-01 Un-Biased Statistics Average Un-Biased 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 Std Dev Un-Biased 1.33E-03 1.37E-03 1.36E-03 1.38E-03 1.43E-03 Ps90%/90% (+KTL) Un-Biased 1.33E-01 1.33E-01 1.33E-01 1.34E-01 1.34E-01 Ps90%/90% (-KTL) Un-Biased 1.26E-01 1.26E-01 1.26E-01 1.26E-01 1.27E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 304 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.147. Plot of Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 305 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.147. Raw data for Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High6 3 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=2.5mA Device 0 10 20 30 50 284 1.29E-01 1.30E-01 1.30E-01 1.31E-01 1.32E-01 303 1.29E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 314 1.24E-01 1.25E-01 1.26E-01 1.26E-01 1.27E-01 331 1.32E-01 1.33E-01 1.33E-01 1.34E-01 1.35E-01 368 1.28E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 404 1.27E-01 1.27E-01 1.27E-01 1.28E-01 1.28E-01 445 1.30E-01 1.30E-01 1.30E-01 1.30E-01 1.31E-01 474 1.29E-01 1.30E-01 1.30E-01 1.30E-01 1.31E-01 500 1.30E-01 1.30E-01 1.30E-01 1.31E-01 1.32E-01 518 1.30E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 524 1.29E-01 1.29E-01 1.29E-01 1.29E-01 1.30E-01 558 1.25E-01 1.25E-01 1.25E-01 1.25E-01 1.25E-01 Biased Statistics Average Biased 1.28E-01 1.29E-01 1.30E-01 1.30E-01 1.31E-01 Std Dev Biased 2.78E-03 2.88E-03 2.77E-03 2.69E-03 2.82E-03 Ps90%/90% (+KTL) Biased 1.36E-01 1.37E-01 1.38E-01 1.38E-01 1.39E-01 Ps90%/90% (-KTL) Biased 1.21E-01 1.21E-01 1.22E-01 1.23E-01 1.23E-01 Un-Biased Statistics Average Un-Biased 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.31E-01 Std Dev Un-Biased 1.34E-03 1.43E-03 1.44E-03 1.41E-03 1.47E-03 Ps90%/90% (+KTL) Un-Biased 1.33E-01 1.33E-01 1.34E-01 1.34E-01 1.35E-01 Ps90%/90% (-KTL) Un-Biased 1.26E-01 1.25E-01 1.26E-01 1.26E-01 1.27E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 306 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.148. Plot of Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 307 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.148. Raw data for Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing High6 4 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=2.5mA Device 0 10 20 30 50 284 1.30E-01 1.31E-01 1.31E-01 1.31E-01 1.32E-01 303 1.31E-01 1.32E-01 1.32E-01 1.33E-01 1.34E-01 314 1.29E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 331 1.32E-01 1.33E-01 1.33E-01 1.33E-01 1.34E-01 368 1.28E-01 1.28E-01 1.29E-01 1.30E-01 1.30E-01 404 1.25E-01 1.25E-01 1.25E-01 1.26E-01 1.26E-01 445 1.26E-01 1.26E-01 1.26E-01 1.27E-01 1.27E-01 474 1.30E-01 1.30E-01 1.30E-01 1.31E-01 1.31E-01 500 1.32E-01 1.32E-01 1.32E-01 1.33E-01 1.33E-01 518 1.30E-01 1.30E-01 1.31E-01 1.31E-01 1.32E-01 524 1.29E-01 1.29E-01 1.30E-01 1.30E-01 1.30E-01 558 1.27E-01 1.26E-01 1.27E-01 1.27E-01 1.27E-01 Biased Statistics Average Biased 1.30E-01 1.31E-01 1.31E-01 1.32E-01 1.32E-01 Std Dev Biased 1.43E-03 1.78E-03 1.41E-03 1.41E-03 1.51E-03 Ps90%/90% (+KTL) Biased 1.34E-01 1.36E-01 1.35E-01 1.36E-01 1.37E-01 Ps90%/90% (-KTL) Biased 1.26E-01 1.26E-01 1.27E-01 1.28E-01 1.28E-01 Un-Biased Statistics Average Un-Biased 1.28E-01 1.28E-01 1.29E-01 1.29E-01 1.30E-01 Std Dev Un-Biased 2.93E-03 3.03E-03 3.04E-03 3.03E-03 3.10E-03 Ps90%/90% (+KTL) Un-Biased 1.36E-01 1.37E-01 1.37E-01 1.38E-01 1.38E-01 Ps90%/90% (-KTL) Un-Biased 1.20E-01 1.20E-01 1.20E-01 1.21E-01 1.21E-01 Specification MAX 2.50E-01 2.50E-01 2.50E-01 2.50E-01 2.50E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 308 Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.149. Plot of Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 309 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.149. Raw data for Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low4 1 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=0mA Device 0 10 20 30 50 284 1.55E-02 1.57E-02 1.58E-02 1.56E-02 1.58E-02 303 1.50E-02 1.51E-02 1.53E-02 1.54E-02 1.55E-02 314 1.52E-02 1.52E-02 1.53E-02 1.55E-02 1.56E-02 331 1.50E-02 1.51E-02 1.53E-02 1.53E-02 1.54E-02 368 1.49E-02 1.52E-02 1.53E-02 1.52E-02 1.55E-02 404 1.52E-02 1.53E-02 1.54E-02 1.56E-02 1.56E-02 445 1.52E-02 1.52E-02 1.53E-02 1.55E-02 1.56E-02 474 1.53E-02 1.53E-02 1.54E-02 1.55E-02 1.56E-02 500 1.51E-02 1.50E-02 1.54E-02 1.54E-02 1.55E-02 518 1.53E-02 1.52E-02 1.53E-02 1.53E-02 1.56E-02 524 1.53E-02 1.53E-02 1.55E-02 1.54E-02 1.54E-02 558 1.51E-02 1.50E-02 1.50E-02 1.52E-02 1.52E-02 Biased Statistics Average Biased 1.51E-02 1.53E-02 1.54E-02 1.54E-02 1.56E-02 Std Dev Biased 2.29E-04 2.68E-04 2.03E-04 1.49E-04 1.61E-04 Ps90%/90% (+KTL) Biased 1.57E-02 1.60E-02 1.59E-02 1.58E-02 1.60E-02 Ps90%/90% (-KTL) Biased 1.45E-02 1.45E-02 1.48E-02 1.50E-02 1.51E-02 Un-Biased Statistics Average Un-Biased 1.52E-02 1.52E-02 1.54E-02 1.55E-02 1.56E-02 Std Dev Un-Biased 6.88E-05 1.31E-04 4.82E-05 1.15E-04 2.59E-05 Ps90%/90% (+KTL) Un-Biased 1.54E-02 1.56E-02 1.55E-02 1.58E-02 1.56E-02 Ps90%/90% (-KTL) Un-Biased 1.50E-02 1.49E-02 1.52E-02 1.52E-02 1.55E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 310 Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.150. Plot of Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 311 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.150. Raw data for Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low4 2 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=0mA Device 0 10 20 30 50 284 1.55E-02 1.56E-02 1.56E-02 1.57E-02 1.60E-02 303 1.51E-02 1.53E-02 1.52E-02 1.55E-02 1.56E-02 314 1.54E-02 1.54E-02 1.56E-02 1.55E-02 1.57E-02 331 1.54E-02 1.56E-02 1.55E-02 1.55E-02 1.57E-02 368 1.56E-02 1.58E-02 1.58E-02 1.57E-02 1.59E-02 404 1.55E-02 1.55E-02 1.57E-02 1.56E-02 1.58E-02 445 1.58E-02 1.57E-02 1.58E-02 1.59E-02 1.60E-02 474 1.52E-02 1.51E-02 1.53E-02 1.53E-02 1.56E-02 500 1.53E-02 1.53E-02 1.55E-02 1.55E-02 1.57E-02 518 1.53E-02 1.55E-02 1.57E-02 1.57E-02 1.59E-02 524 1.57E-02 1.56E-02 1.58E-02 1.55E-02 1.56E-02 558 1.53E-02 1.52E-02 1.52E-02 1.53E-02 1.55E-02 Biased Statistics Average Biased 1.54E-02 1.55E-02 1.55E-02 1.56E-02 1.58E-02 Std Dev Biased 1.89E-04 1.95E-04 2.19E-04 7.95E-05 1.69E-04 Ps90%/90% (+KTL) Biased 1.59E-02 1.60E-02 1.61E-02 1.58E-02 1.62E-02 Ps90%/90% (-KTL) Biased 1.49E-02 1.50E-02 1.49E-02 1.54E-02 1.53E-02 Un-Biased Statistics Average Un-Biased 1.54E-02 1.54E-02 1.56E-02 1.56E-02 1.58E-02 Std Dev Un-Biased 2.47E-04 2.35E-04 2.11E-04 2.32E-04 1.80E-04 Ps90%/90% (+KTL) Un-Biased 1.61E-02 1.61E-02 1.62E-02 1.62E-02 1.63E-02 Ps90%/90% (-KTL) Un-Biased 1.48E-02 1.48E-02 1.50E-02 1.50E-02 1.53E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 312 Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.151. Plot of Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 313 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.151. Raw data for Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low4 3 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=0mA Device 0 10 20 30 50 284 1.50E-02 1.51E-02 1.53E-02 1.53E-02 1.55E-02 303 1.49E-02 1.49E-02 1.49E-02 1.51E-02 1.54E-02 314 1.52E-02 1.52E-02 1.54E-02 1.54E-02 1.56E-02 331 1.50E-02 1.52E-02 1.52E-02 1.54E-02 1.56E-02 368 1.53E-02 1.53E-02 1.56E-02 1.55E-02 1.57E-02 404 1.50E-02 1.49E-02 1.53E-02 1.53E-02 1.54E-02 445 1.54E-02 1.54E-02 1.53E-02 1.57E-02 1.56E-02 474 1.49E-02 1.49E-02 1.49E-02 1.53E-02 1.53E-02 500 1.52E-02 1.52E-02 1.54E-02 1.54E-02 1.55E-02 518 1.51E-02 1.52E-02 1.53E-02 1.55E-02 1.56E-02 524 1.54E-02 1.54E-02 1.55E-02 1.55E-02 1.55E-02 558 1.48E-02 1.49E-02 1.48E-02 1.48E-02 1.48E-02 Biased Statistics Average Biased 1.51E-02 1.52E-02 1.53E-02 1.53E-02 1.55E-02 Std Dev Biased 1.67E-04 1.34E-04 2.24E-04 1.62E-04 1.08E-04 Ps90%/90% (+KTL) Biased 1.55E-02 1.55E-02 1.59E-02 1.58E-02 1.58E-02 Ps90%/90% (-KTL) Biased 1.46E-02 1.48E-02 1.47E-02 1.49E-02 1.52E-02 Un-Biased Statistics Average Un-Biased 1.51E-02 1.51E-02 1.52E-02 1.54E-02 1.55E-02 Std Dev Un-Biased 2.04E-04 1.92E-04 2.02E-04 1.69E-04 9.68E-05 Ps90%/90% (+KTL) Un-Biased 1.57E-02 1.57E-02 1.58E-02 1.59E-02 1.57E-02 Ps90%/90% (-KTL) Un-Biased 1.46E-02 1.46E-02 1.47E-02 1.50E-02 1.52E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 314 Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 7.00E-02 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.152. Plot of Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 315 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.152. Raw data for Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low4 4 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=0mA Device 0 10 20 30 50 284 1.56E-02 1.58E-02 1.59E-02 1.58E-02 1.61E-02 303 1.52E-02 1.53E-02 1.55E-02 1.55E-02 1.56E-02 314 1.55E-02 1.57E-02 1.58E-02 1.58E-02 1.60E-02 331 1.53E-02 1.56E-02 1.57E-02 1.54E-02 1.57E-02 368 1.53E-02 1.52E-02 1.56E-02 1.55E-02 1.54E-02 404 1.54E-02 1.53E-02 1.56E-02 1.55E-02 1.57E-02 445 1.54E-02 1.54E-02 1.55E-02 1.56E-02 1.57E-02 474 1.53E-02 1.53E-02 1.53E-02 1.55E-02 1.56E-02 500 1.54E-02 1.55E-02 1.55E-02 1.57E-02 1.58E-02 518 1.53E-02 1.53E-02 1.56E-02 1.57E-02 1.57E-02 524 1.55E-02 1.55E-02 1.57E-02 1.55E-02 1.56E-02 558 1.54E-02 1.54E-02 1.55E-02 1.55E-02 1.54E-02 Biased Statistics Average Biased 1.54E-02 1.55E-02 1.57E-02 1.56E-02 1.57E-02 Std Dev Biased 1.48E-04 2.58E-04 1.72E-04 1.73E-04 2.81E-04 Ps90%/90% (+KTL) Biased 1.58E-02 1.62E-02 1.62E-02 1.61E-02 1.65E-02 Ps90%/90% (-KTL) Biased 1.50E-02 1.48E-02 1.52E-02 1.51E-02 1.50E-02 Un-Biased Statistics Average Un-Biased 1.54E-02 1.54E-02 1.55E-02 1.56E-02 1.57E-02 Std Dev Un-Biased 3.21E-05 7.68E-05 9.37E-05 1.00E-04 7.54E-05 Ps90%/90% (+KTL) Un-Biased 1.54E-02 1.56E-02 1.57E-02 1.58E-02 1.59E-02 Ps90%/90% (-KTL) Un-Biased 1.53E-02 1.51E-02 1.52E-02 1.53E-02 1.55E-02 Specification MAX 3.00E-02 6.00E-02 6.00E-02 6.00E-02 6.00E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 316 Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.153. Plot of Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 317 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.153. Raw data for Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low5 1 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=1mA Device 0 10 20 30 50 284 3.42E-02 3.44E-02 3.46E-02 3.45E-02 3.48E-02 303 3.39E-02 3.41E-02 3.42E-02 3.42E-02 3.44E-02 314 3.40E-02 3.41E-02 3.43E-02 3.42E-02 3.45E-02 331 3.36E-02 3.39E-02 3.40E-02 3.40E-02 3.41E-02 368 3.36E-02 3.37E-02 3.42E-02 3.41E-02 3.42E-02 404 3.39E-02 3.38E-02 3.40E-02 3.40E-02 3.42E-02 445 3.38E-02 3.36E-02 3.38E-02 3.41E-02 3.42E-02 474 3.40E-02 3.42E-02 3.41E-02 3.42E-02 3.43E-02 500 3.41E-02 3.40E-02 3.40E-02 3.42E-02 3.42E-02 518 3.41E-02 3.41E-02 3.41E-02 3.41E-02 3.43E-02 524 3.40E-02 3.38E-02 3.39E-02 3.39E-02 3.39E-02 558 3.38E-02 3.36E-02 3.37E-02 3.36E-02 3.37E-02 Biased Statistics Average Biased 3.39E-02 3.41E-02 3.43E-02 3.42E-02 3.44E-02 Std Dev Biased 2.42E-04 2.80E-04 2.14E-04 1.87E-04 2.73E-04 Ps90%/90% (+KTL) Biased 3.45E-02 3.48E-02 3.48E-02 3.47E-02 3.51E-02 Ps90%/90% (-KTL) Biased 3.32E-02 3.33E-02 3.37E-02 3.37E-02 3.36E-02 Un-Biased Statistics Average Un-Biased 3.40E-02 3.39E-02 3.40E-02 3.41E-02 3.42E-02 Std Dev Un-Biased 1.39E-04 2.19E-04 1.41E-04 1.04E-04 6.73E-05 Ps90%/90% (+KTL) Un-Biased 3.44E-02 3.45E-02 3.44E-02 3.44E-02 3.44E-02 Ps90%/90% (-KTL) Un-Biased 3.36E-02 3.33E-02 3.36E-02 3.38E-02 3.40E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 318 Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.154. Plot of Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 319 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.154. Raw data for Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low5 2 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=1mA Device 0 10 20 30 50 284 3.43E-02 3.44E-02 3.46E-02 3.46E-02 3.49E-02 303 3.40E-02 3.41E-02 3.41E-02 3.42E-02 3.44E-02 314 3.41E-02 3.41E-02 3.43E-02 3.43E-02 3.44E-02 331 3.44E-02 3.47E-02 3.47E-02 3.48E-02 3.48E-02 368 3.41E-02 3.44E-02 3.45E-02 3.47E-02 3.47E-02 404 3.41E-02 3.42E-02 3.43E-02 3.43E-02 3.45E-02 445 3.49E-02 3.48E-02 3.48E-02 3.50E-02 3.51E-02 474 3.41E-02 3.41E-02 3.42E-02 3.42E-02 3.44E-02 500 3.41E-02 3.42E-02 3.44E-02 3.44E-02 3.46E-02 518 3.43E-02 3.45E-02 3.46E-02 3.47E-02 3.48E-02 524 3.46E-02 3.46E-02 3.46E-02 3.45E-02 3.45E-02 558 3.37E-02 3.37E-02 3.40E-02 3.37E-02 3.39E-02 Biased Statistics Average Biased 3.42E-02 3.43E-02 3.45E-02 3.45E-02 3.46E-02 Std Dev Biased 1.64E-04 2.49E-04 2.53E-04 2.32E-04 2.40E-04 Ps90%/90% (+KTL) Biased 3.46E-02 3.50E-02 3.51E-02 3.51E-02 3.53E-02 Ps90%/90% (-KTL) Biased 3.37E-02 3.37E-02 3.38E-02 3.39E-02 3.40E-02 Un-Biased Statistics Average Un-Biased 3.43E-02 3.43E-02 3.45E-02 3.45E-02 3.47E-02 Std Dev Un-Biased 3.50E-04 2.94E-04 2.22E-04 3.22E-04 2.89E-04 Ps90%/90% (+KTL) Un-Biased 3.53E-02 3.51E-02 3.51E-02 3.54E-02 3.55E-02 Ps90%/90% (-KTL) Un-Biased 3.33E-02 3.35E-02 3.38E-02 3.36E-02 3.39E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 320 Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.155. Plot of Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 321 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.155. Raw data for Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low5 3 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=1mA Device 0 10 20 30 50 284 3.37E-02 3.40E-02 3.39E-02 3.40E-02 3.42E-02 303 3.37E-02 3.37E-02 3.39E-02 3.40E-02 3.43E-02 314 3.37E-02 3.37E-02 3.39E-02 3.40E-02 3.42E-02 331 3.40E-02 3.41E-02 3.42E-02 3.43E-02 3.44E-02 368 3.38E-02 3.40E-02 3.43E-02 3.42E-02 3.43E-02 404 3.39E-02 3.37E-02 3.39E-02 3.39E-02 3.41E-02 445 3.40E-02 3.39E-02 3.40E-02 3.42E-02 3.45E-02 474 3.36E-02 3.36E-02 3.37E-02 3.39E-02 3.40E-02 500 3.40E-02 3.39E-02 3.40E-02 3.41E-02 3.42E-02 518 3.41E-02 3.42E-02 3.42E-02 3.44E-02 3.44E-02 524 3.42E-02 3.40E-02 3.43E-02 3.42E-02 3.43E-02 558 3.33E-02 3.33E-02 3.33E-02 3.33E-02 3.33E-02 Biased Statistics Average Biased 3.38E-02 3.39E-02 3.40E-02 3.41E-02 3.43E-02 Std Dev Biased 1.43E-04 1.77E-04 2.22E-04 1.34E-04 9.61E-05 Ps90%/90% (+KTL) Biased 3.42E-02 3.44E-02 3.46E-02 3.45E-02 3.45E-02 Ps90%/90% (-KTL) Biased 3.34E-02 3.34E-02 3.34E-02 3.37E-02 3.40E-02 Un-Biased Statistics Average Un-Biased 3.39E-02 3.39E-02 3.39E-02 3.41E-02 3.42E-02 Std Dev Un-Biased 2.19E-04 2.10E-04 1.98E-04 2.08E-04 1.90E-04 Ps90%/90% (+KTL) Un-Biased 3.45E-02 3.44E-02 3.45E-02 3.47E-02 3.47E-02 Ps90%/90% (-KTL) Un-Biased 3.33E-02 3.33E-02 3.34E-02 3.35E-02 3.37E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 322 Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased 1.20E-01 1.00E-01 8.00E-02 6.00E-02 4.00E-02 2.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.156. Plot of Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 323 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.156. Raw data for Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low5 4 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=1mA Device 0 10 20 30 50 284 3.47E-02 3.50E-02 3.49E-02 3.50E-02 3.53E-02 303 3.42E-02 3.44E-02 3.45E-02 3.46E-02 3.49E-02 314 3.44E-02 3.45E-02 3.47E-02 3.49E-02 3.48E-02 331 3.41E-02 3.43E-02 3.45E-02 3.45E-02 3.48E-02 368 3.38E-02 3.40E-02 3.43E-02 3.42E-02 3.43E-02 404 3.40E-02 3.40E-02 3.43E-02 3.42E-02 3.45E-02 445 3.42E-02 3.42E-02 3.41E-02 3.43E-02 3.46E-02 474 3.45E-02 3.43E-02 3.45E-02 3.46E-02 3.46E-02 500 3.43E-02 3.45E-02 3.44E-02 3.47E-02 3.48E-02 518 3.43E-02 3.43E-02 3.46E-02 3.47E-02 3.47E-02 524 3.44E-02 3.44E-02 3.44E-02 3.43E-02 3.43E-02 558 3.43E-02 3.42E-02 3.43E-02 3.41E-02 3.43E-02 Biased Statistics Average Biased 3.42E-02 3.44E-02 3.46E-02 3.46E-02 3.48E-02 Std Dev Biased 3.34E-04 3.68E-04 2.41E-04 3.42E-04 3.74E-04 Ps90%/90% (+KTL) Biased 3.52E-02 3.54E-02 3.53E-02 3.56E-02 3.58E-02 Ps90%/90% (-KTL) Biased 3.33E-02 3.34E-02 3.39E-02 3.37E-02 3.38E-02 Un-Biased Statistics Average Un-Biased 3.43E-02 3.43E-02 3.44E-02 3.45E-02 3.46E-02 Std Dev Un-Biased 1.65E-04 1.53E-04 1.83E-04 2.21E-04 1.26E-04 Ps90%/90% (+KTL) Un-Biased 3.47E-02 3.47E-02 3.49E-02 3.51E-02 3.50E-02 Ps90%/90% (-KTL) Un-Biased 3.38E-02 3.38E-02 3.39E-02 3.39E-02 3.43E-02 Specification MAX 1.00E-01 1.00E-01 1.00E-01 1.00E-01 1.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 324 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.157. Plot of Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 325 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.157. Raw data for Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low6 1 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=2.5mA Device 0 10 20 30 50 284 7.45E-02 7.47E-02 7.48E-02 7.49E-02 7.51E-02 303 7.41E-02 7.43E-02 7.42E-02 7.45E-02 7.48E-02 314 7.40E-02 7.41E-02 7.44E-02 7.45E-02 7.47E-02 331 7.37E-02 7.40E-02 7.42E-02 7.43E-02 7.46E-02 368 7.35E-02 7.32E-02 7.36E-02 7.38E-02 7.39E-02 404 7.35E-02 7.33E-02 7.36E-02 7.38E-02 7.39E-02 445 7.38E-02 7.36E-02 7.38E-02 7.40E-02 7.40E-02 474 7.43E-02 7.43E-02 7.43E-02 7.44E-02 7.46E-02 500 7.41E-02 7.42E-02 7.42E-02 7.45E-02 7.47E-02 518 7.40E-02 7.41E-02 7.42E-02 7.44E-02 7.46E-02 524 7.43E-02 7.40E-02 7.42E-02 7.40E-02 7.41E-02 558 7.35E-02 7.32E-02 7.36E-02 7.35E-02 7.35E-02 Biased Statistics Average Biased 7.40E-02 7.41E-02 7.42E-02 7.44E-02 7.46E-02 Std Dev Biased 3.93E-04 5.47E-04 4.19E-04 3.77E-04 4.56E-04 Ps90%/90% (+KTL) Biased 7.50E-02 7.56E-02 7.54E-02 7.54E-02 7.59E-02 Ps90%/90% (-KTL) Biased 7.29E-02 7.26E-02 7.31E-02 7.34E-02 7.34E-02 Un-Biased Statistics Average Un-Biased 7.39E-02 7.39E-02 7.40E-02 7.42E-02 7.43E-02 Std Dev Un-Biased 3.15E-04 4.15E-04 2.90E-04 2.99E-04 3.70E-04 Ps90%/90% (+KTL) Un-Biased 7.48E-02 7.51E-02 7.48E-02 7.50E-02 7.53E-02 Ps90%/90% (-KTL) Un-Biased 7.31E-02 7.28E-02 7.32E-02 7.34E-02 7.33E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 326 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.158. Plot of Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 327 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.158. Raw data for Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low6 2 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=2.5mA Device 0 10 20 30 50 284 7.44E-02 7.49E-02 7.47E-02 7.48E-02 7.52E-02 303 7.41E-02 7.41E-02 7.45E-02 7.44E-02 7.49E-02 314 7.37E-02 7.38E-02 7.39E-02 7.40E-02 7.43E-02 331 7.50E-02 7.51E-02 7.54E-02 7.54E-02 7.56E-02 368 7.44E-02 7.43E-02 7.46E-02 7.47E-02 7.47E-02 404 7.39E-02 7.40E-02 7.40E-02 7.42E-02 7.44E-02 445 7.53E-02 7.51E-02 7.53E-02 7.55E-02 7.56E-02 474 7.46E-02 7.43E-02 7.45E-02 7.47E-02 7.48E-02 500 7.47E-02 7.46E-02 7.47E-02 7.50E-02 7.51E-02 518 7.50E-02 7.49E-02 7.49E-02 7.53E-02 7.53E-02 524 7.50E-02 7.48E-02 7.51E-02 7.50E-02 7.51E-02 558 7.36E-02 7.35E-02 7.38E-02 7.37E-02 7.38E-02 Biased Statistics Average Biased 7.43E-02 7.44E-02 7.46E-02 7.47E-02 7.49E-02 Std Dev Biased 4.52E-04 5.29E-04 5.28E-04 5.05E-04 4.95E-04 Ps90%/90% (+KTL) Biased 7.55E-02 7.59E-02 7.61E-02 7.61E-02 7.63E-02 Ps90%/90% (-KTL) Biased 7.31E-02 7.30E-02 7.32E-02 7.33E-02 7.36E-02 Un-Biased Statistics Average Un-Biased 7.47E-02 7.46E-02 7.47E-02 7.49E-02 7.51E-02 Std Dev Un-Biased 5.07E-04 4.52E-04 4.68E-04 4.97E-04 4.63E-04 Ps90%/90% (+KTL) Un-Biased 7.61E-02 7.58E-02 7.59E-02 7.63E-02 7.63E-02 Ps90%/90% (-KTL) Un-Biased 7.33E-02 7.33E-02 7.34E-02 7.36E-02 7.38E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 328 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.159. Plot of Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 329 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.159. Raw data for Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low6 3 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=2.5mA Device 0 10 20 30 50 284 7.35E-02 7.39E-02 7.39E-02 7.39E-02 7.42E-02 303 7.36E-02 7.36E-02 7.39E-02 7.39E-02 7.43E-02 314 7.31E-02 7.32E-02 7.34E-02 7.35E-02 7.37E-02 331 7.42E-02 7.42E-02 7.45E-02 7.46E-02 7.46E-02 368 7.38E-02 7.37E-02 7.43E-02 7.40E-02 7.43E-02 404 7.35E-02 7.34E-02 7.36E-02 7.36E-02 7.38E-02 445 7.41E-02 7.39E-02 7.40E-02 7.42E-02 7.45E-02 474 7.37E-02 7.37E-02 7.36E-02 7.38E-02 7.39E-02 500 7.40E-02 7.39E-02 7.40E-02 7.39E-02 7.42E-02 518 7.42E-02 7.42E-02 7.43E-02 7.45E-02 7.47E-02 524 7.43E-02 7.41E-02 7.44E-02 7.43E-02 7.42E-02 558 7.29E-02 7.26E-02 7.29E-02 7.29E-02 7.29E-02 Biased Statistics Average Biased 7.37E-02 7.37E-02 7.40E-02 7.40E-02 7.42E-02 Std Dev Biased 4.11E-04 3.82E-04 4.16E-04 3.98E-04 3.22E-04 Ps90%/90% (+KTL) Biased 7.48E-02 7.48E-02 7.51E-02 7.51E-02 7.51E-02 Ps90%/90% (-KTL) Biased 7.25E-02 7.27E-02 7.29E-02 7.29E-02 7.34E-02 Un-Biased Statistics Average Un-Biased 7.39E-02 7.38E-02 7.39E-02 7.40E-02 7.42E-02 Std Dev Un-Biased 2.89E-04 2.90E-04 3.10E-04 3.60E-04 3.82E-04 Ps90%/90% (+KTL) Un-Biased 7.47E-02 7.46E-02 7.47E-02 7.50E-02 7.53E-02 Ps90%/90% (-KTL) Un-Biased 7.31E-02 7.30E-02 7.30E-02 7.30E-02 7.32E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 330 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.160. Plot of Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 331 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.160. Raw data for Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Voltage Swing Low6 4 5V (V) Total Dose (krad(Si)) @ VS=+5V IL=2.5mA Device 0 10 20 30 50 284 7.51E-02 7.57E-02 7.55E-02 7.56E-02 7.60E-02 303 7.47E-02 7.47E-02 7.49E-02 7.51E-02 7.54E-02 314 7.49E-02 7.47E-02 7.50E-02 7.52E-02 7.55E-02 331 7.47E-02 7.47E-02 7.50E-02 7.51E-02 7.54E-02 368 7.37E-02 7.37E-02 7.39E-02 7.38E-02 7.43E-02 404 7.39E-02 7.38E-02 7.41E-02 7.41E-02 7.44E-02 445 7.44E-02 7.42E-02 7.43E-02 7.45E-02 7.48E-02 474 7.49E-02 7.49E-02 7.49E-02 7.50E-02 7.51E-02 500 7.49E-02 7.49E-02 7.49E-02 7.50E-02 7.53E-02 518 7.50E-02 7.49E-02 7.50E-02 7.50E-02 7.52E-02 524 7.47E-02 7.46E-02 7.48E-02 7.48E-02 7.48E-02 558 7.43E-02 7.41E-02 7.44E-02 7.44E-02 7.43E-02 Biased Statistics Average Biased 7.46E-02 7.47E-02 7.49E-02 7.49E-02 7.53E-02 Std Dev Biased 5.18E-04 7.08E-04 5.94E-04 6.84E-04 6.23E-04 Ps90%/90% (+KTL) Biased 7.60E-02 7.66E-02 7.65E-02 7.68E-02 7.70E-02 Ps90%/90% (-KTL) Biased 7.32E-02 7.28E-02 7.32E-02 7.30E-02 7.36E-02 Un-Biased Statistics Average Un-Biased 7.46E-02 7.45E-02 7.46E-02 7.47E-02 7.50E-02 Std Dev Un-Biased 4.65E-04 5.01E-04 4.26E-04 4.10E-04 3.62E-04 Ps90%/90% (+KTL) Un-Biased 7.59E-02 7.59E-02 7.58E-02 7.58E-02 7.60E-02 Ps90%/90% (-KTL) Un-Biased 7.34E-02 7.32E-02 7.35E-02 7.36E-02 7.40E-02 Specification MAX 2.00E-01 2.00E-01 2.00E-01 2.00E-01 2.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 332 Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.00E+06 5.00E+05 0.00E+00 -5.00E+05 -1.00E+06 -1.50E+06 -2.00E+06 -2.50E+06 -3.00E+06 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.161. Plot of Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 333 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.161. Raw data for Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 2.46E+04 4.81E+03 1.39E+04 1.38E+04 3.72E+03 1.52E+04 6.43E+03 1.61E+04 1.28E+04 1.36E+04 3.87E+03 4.70E+03 Total 10 2.49E+04 4.11E+03 1.94E+04 2.95E+03 3.06E+03 1.22E+04 1.02E+04 2.73E+06 7.66E+03 2.04E+04 3.37E+03 3.40E+03 Dose (krad(Si)) 20 30 1.45E+04 9.79E+03 7.01E+03 5.34E+03 1.07E+04 1.95E+04 3.03E+03 2.94E+03 2.68E+03 2.70E+03 8.40E+03 1.46E+04 7.81E+03 5.35E+03 1.92E+04 8.02E+04 2.29E+04 8.69E+03 2.84E+04 1.62E+05 3.98E+03 3.52E+03 5.24E+03 3.73E+04 50 1.98E+04 3.88E+03 2.49E+04 3.35E+03 3.47E+03 9.07E+03 1.82E+04 1.24E+05 9.05E+04 3.44E+04 3.81E+03 7.11E+03 1.22E+04 8.46E+03 3.54E+04 -1.10E+04 1.09E+04 1.05E+04 3.96E+04 -1.78E+04 7.57E+03 5.05E+03 2.14E+04 -6.28E+03 8.06E+03 7.02E+03 2.73E+04 -1.12E+04 1.11E+04 1.04E+04 3.97E+04 -1.76E+04 1.28E+04 3.79E+03 2.32E+04 2.43E+03 6.00E+02 PASS 5.55E+05 1.21E+06 3.88E+06 -2.77E+06 3.00E+02 PASS 1.73E+04 9.06E+03 4.22E+04 -7.49E+03 3.00E+02 PASS 5.42E+04 6.78E+04 2.40E+05 -1.32E+05 3.00E+02 PASS 5.53E+04 4.99E+04 1.92E+05 -8.15E+04 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 334 Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.50E+04 1.00E+04 5.00E+03 0.00E+00 -5.00E+03 -1.00E+04 -1.50E+04 -2.00E+04 -2.50E+04 -3.00E+04 -3.50E+04 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.162. Plot of Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 335 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.162. Raw data for Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 5.68E+03 2.22E+03 3.59E+03 1.91E+03 2.81E+03 2.04E+03 2.62E+03 4.87E+03 2.62E+03 5.59E+03 2.19E+03 4.12E+03 Total 10 3.91E+03 2.36E+03 3.62E+03 3.57E+04 2.48E+03 1.72E+03 3.29E+03 4.56E+03 2.15E+03 6.55E+03 2.14E+03 5.05E+03 Dose (krad(Si)) 20 30 4.29E+03 4.12E+03 2.52E+03 2.16E+03 3.50E+03 3.01E+03 3.53E+03 1.98E+03 2.48E+03 2.53E+03 1.90E+03 1.80E+03 2.89E+03 3.13E+03 5.69E+03 4.28E+03 2.75E+03 2.19E+03 4.80E+03 8.36E+03 2.13E+03 2.24E+03 4.74E+03 4.65E+03 50 3.26E+03 2.25E+03 3.50E+03 5.27E+03 2.95E+03 1.80E+03 3.34E+03 5.70E+03 2.59E+03 7.56E+03 2.29E+03 5.12E+03 3.24E+03 1.51E+03 7.38E+03 -8.96E+02 9.60E+03 1.46E+04 4.96E+04 -3.04E+04 3.26E+03 7.63E+02 5.36E+03 1.17E+03 2.76E+03 8.58E+02 5.11E+03 4.07E+02 3.45E+03 1.12E+03 6.52E+03 3.71E+02 3.55E+03 1.57E+03 7.86E+03 -7.69E+02 6.00E+02 PASS 3.65E+03 1.96E+03 9.02E+03 -1.71E+03 3.00E+02 PASS 3.60E+03 1.58E+03 7.93E+03 -7.21E+02 3.00E+02 PASS 3.95E+03 2.64E+03 1.12E+04 -3.29E+03 3.00E+02 PASS 4.20E+03 2.38E+03 1.07E+04 -2.33E+03 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 336 Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 4.00E+03 3.50E+03 3.00E+03 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 -5.00E+02 -1.00E+03 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.163. Plot of Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 337 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.163. Raw data for Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 3.36E+03 3.19E+03 2.88E+03 4.39E+03 2.35E+03 4.33E+03 3.17E+03 2.31E+03 2.22E+03 2.42E+03 2.55E+03 3.18E+03 Total 10 2.72E+03 3.18E+03 3.10E+03 3.64E+03 2.06E+03 4.93E+03 2.94E+03 2.56E+03 2.57E+03 2.95E+03 2.54E+03 3.27E+03 Dose (krad(Si)) 20 30 3.51E+03 1.65E+03 3.75E+03 2.80E+03 3.99E+03 2.60E+03 4.44E+03 4.79E+03 2.25E+03 2.51E+03 4.27E+03 3.24E+03 2.87E+03 3.15E+03 2.23E+03 2.38E+03 2.21E+03 2.30E+03 2.33E+03 2.49E+03 2.28E+03 2.58E+03 2.89E+03 3.39E+03 50 2.80E+03 2.95E+03 2.93E+03 3.64E+03 1.97E+03 3.31E+03 3.41E+03 2.45E+03 2.97E+03 2.21E+03 2.87E+03 2.96E+03 3.23E+03 7.55E+02 5.30E+03 1.16E+03 2.94E+03 5.90E+02 4.56E+03 1.32E+03 3.59E+03 8.22E+02 5.84E+03 1.33E+03 2.87E+03 1.16E+03 6.05E+03 -3.06E+02 2.86E+03 5.95E+02 4.49E+03 1.23E+03 2.89E+03 8.88E+02 5.32E+03 4.52E+02 6.00E+02 PASS 3.19E+03 9.92E+02 5.91E+03 4.71E+02 3.00E+02 PASS 2.78E+03 8.76E+02 5.18E+03 3.81E+02 3.00E+02 PASS 2.71E+03 4.46E+02 3.93E+03 1.49E+03 3.00E+02 PASS 2.87E+03 5.25E+02 4.31E+03 1.43E+03 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 338 Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 3.50E+03 3.00E+03 2.50E+03 2.00E+03 1.50E+03 1.00E+03 5.00E+02 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.164. Plot of Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 339 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.164. Raw data for Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 2.26E+03 2.47E+03 2.52E+03 1.81E+03 2.20E+03 2.45E+03 3.77E+03 2.44E+03 3.32E+03 2.42E+03 2.24E+03 2.17E+03 Total 10 2.04E+03 2.67E+03 2.44E+03 1.80E+03 2.46E+03 2.22E+03 3.08E+03 3.30E+03 3.82E+03 2.03E+03 1.99E+03 1.89E+03 Dose (krad(Si)) 20 30 2.35E+03 2.18E+03 2.64E+03 2.37E+03 2.64E+03 2.22E+03 1.77E+03 1.61E+03 2.83E+03 2.41E+03 2.21E+03 2.25E+03 2.94E+03 3.67E+03 2.19E+03 2.16E+03 3.60E+03 3.66E+03 2.53E+03 1.96E+03 2.25E+03 2.40E+03 2.33E+03 2.07E+03 50 2.17E+03 2.66E+03 2.29E+03 1.67E+03 2.32E+03 2.31E+03 3.17E+03 2.31E+03 3.43E+03 1.94E+03 2.13E+03 1.98E+03 2.25E+03 2.85E+02 3.04E+03 1.47E+03 2.28E+03 3.55E+02 3.25E+03 1.31E+03 2.45E+03 4.15E+02 3.59E+03 1.31E+03 2.16E+03 3.21E+02 3.04E+03 1.28E+03 2.22E+03 3.58E+02 3.20E+03 1.24E+03 2.88E+03 6.29E+02 4.60E+03 1.15E+03 6.00E+02 PASS 2.89E+03 7.49E+02 4.94E+03 8.38E+02 3.00E+02 PASS 2.69E+03 5.91E+02 4.31E+03 1.07E+03 3.00E+02 PASS 2.74E+03 8.48E+02 5.07E+03 4.13E+02 3.00E+02 PASS 2.63E+03 6.36E+02 4.38E+03 8.88E+02 3.00E+02 PASS An ISO 9001:2008 and DSCC Certified Company 340 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.165. Plot of Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 341 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.165. Raw data for Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 8.57E+01 1.30E+02 1.05E+02 9.13E+01 9.22E+01 8.94E+01 1.02E+02 1.09E+02 9.17E+01 8.39E+01 9.72E+01 8.64E+01 Total 10 8.53E+01 1.25E+02 1.03E+02 9.10E+01 9.19E+01 8.91E+01 1.01E+02 1.08E+02 9.16E+01 8.39E+01 9.70E+01 8.64E+01 Dose (krad(Si)) 20 30 8.53E+01 8.53E+01 1.28E+02 1.42E+02 1.03E+02 1.02E+02 9.11E+01 9.09E+01 9.18E+01 9.16E+01 8.90E+01 8.90E+01 1.00E+02 9.99E+01 1.07E+02 1.07E+02 9.14E+01 9.13E+01 8.38E+01 8.38E+01 9.71E+01 9.70E+01 8.64E+01 8.64E+01 50 8.54E+01 1.32E+02 1.01E+02 9.08E+01 9.14E+01 8.88E+01 9.94E+01 1.07E+02 9.11E+01 8.38E+01 9.70E+01 8.64E+01 1.01E+02 1.78E+01 1.50E+02 5.21E+01 9.93E+01 1.59E+01 1.43E+02 5.57E+01 9.98E+01 1.68E+01 1.46E+02 5.36E+01 1.02E+02 2.30E+01 1.65E+02 3.95E+01 1.00E+02 1.88E+01 1.52E+02 4.87E+01 9.51E+01 9.91E+00 1.22E+02 6.79E+01 7.60E+01 PASS 9.46E+01 9.63E+00 1.21E+02 6.82E+01 7.00E+01 PASS 9.43E+01 9.36E+00 1.20E+02 6.87E+01 7.00E+01 PASS 9.43E+01 9.33E+00 1.20E+02 6.87E+01 7.00E+01 PASS 9.39E+01 9.03E+00 1.19E+02 6.92E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 342 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.166. Plot of Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 343 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.166. Raw data for Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 8.96E+01 8.66E+01 1.11E+02 9.44E+01 1.08E+02 9.02E+01 9.03E+01 8.90E+01 8.85E+01 8.78E+01 8.73E+01 8.59E+01 Total 10 8.94E+01 8.68E+01 1.14E+02 9.43E+01 1.11E+02 9.01E+01 9.01E+01 8.90E+01 8.84E+01 8.77E+01 8.73E+01 8.58E+01 Dose (krad(Si)) 20 30 8.93E+01 8.93E+01 8.68E+01 8.68E+01 1.15E+02 1.15E+02 9.43E+01 9.42E+01 1.11E+02 1.11E+02 9.00E+01 9.00E+01 8.99E+01 8.98E+01 8.89E+01 8.88E+01 8.83E+01 8.82E+01 8.76E+01 8.75E+01 8.73E+01 8.73E+01 8.59E+01 8.58E+01 50 8.92E+01 8.68E+01 1.16E+02 9.42E+01 1.13E+02 8.99E+01 8.96E+01 8.87E+01 8.81E+01 8.74E+01 8.73E+01 8.58E+01 9.79E+01 1.09E+01 1.28E+02 6.79E+01 9.89E+01 1.24E+01 1.33E+02 6.50E+01 9.92E+01 1.27E+01 1.34E+02 6.42E+01 9.93E+01 1.29E+01 1.35E+02 6.39E+01 9.99E+01 1.38E+01 1.38E+02 6.21E+01 8.92E+01 1.08E+00 9.21E+01 8.62E+01 7.60E+01 PASS 8.91E+01 1.04E+00 9.19E+01 8.62E+01 7.00E+01 PASS 8.89E+01 1.06E+00 9.18E+01 8.60E+01 7.00E+01 PASS 8.89E+01 1.06E+00 9.18E+01 8.59E+01 7.00E+01 PASS 8.88E+01 1.04E+00 9.16E+01 8.59E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 344 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.167. Plot of Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 345 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.167. Raw data for Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 9.59E+01 9.30E+01 1.13E+02 8.85E+01 1.04E+02 1.01E+02 1.21E+02 8.54E+01 9.34E+01 8.94E+01 8.62E+01 9.54E+01 Total 10 9.47E+01 9.26E+01 1.09E+02 8.78E+01 1.05E+02 1.01E+02 1.30E+02 8.53E+01 9.36E+01 8.92E+01 8.61E+01 9.49E+01 Dose (krad(Si)) 20 30 9.38E+01 9.45E+01 9.22E+01 9.22E+01 1.07E+02 1.07E+02 8.83E+01 8.84E+01 1.05E+02 1.04E+02 1.02E+02 1.01E+02 1.15E+02 1.21E+02 8.52E+01 8.53E+01 9.39E+01 9.37E+01 8.92E+01 8.93E+01 8.62E+01 8.63E+01 9.53E+01 9.54E+01 50 9.45E+01 9.22E+01 1.06E+02 8.83E+01 1.05E+02 1.02E+02 1.17E+02 8.52E+01 9.38E+01 8.92E+01 8.64E+01 9.54E+01 9.89E+01 9.68E+00 1.25E+02 7.23E+01 9.77E+01 8.63E+00 1.21E+02 7.40E+01 9.72E+01 8.21E+00 1.20E+02 7.47E+01 9.73E+01 7.97E+00 1.19E+02 7.54E+01 9.72E+01 7.84E+00 1.19E+02 7.57E+01 9.80E+01 1.42E+01 1.37E+02 5.91E+01 7.60E+01 PASS 9.98E+01 1.77E+01 1.48E+02 5.14E+01 7.00E+01 PASS 9.70E+01 1.18E+01 1.29E+02 6.48E+01 7.00E+01 PASS 9.82E+01 1.43E+01 1.37E+02 5.91E+01 7.00E+01 PASS 9.74E+01 1.25E+01 1.32E+02 6.30E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 346 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V 1.00E+02 9.00E+01 8.00E+01 7.00E+01 6.00E+01 5.00E+01 4.00E+01 3.00E+01 2.00E+01 1.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.168. Plot of Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 347 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.168. Raw data for Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 9.22E+01 8.40E+01 8.72E+01 1.02E+02 9.28E+01 8.43E+01 9.84E+01 9.05E+01 9.59E+01 9.52E+01 9.21E+01 9.06E+01 Total 10 9.21E+01 8.42E+01 8.71E+01 1.03E+02 9.28E+01 8.43E+01 9.88E+01 9.04E+01 9.59E+01 9.50E+01 9.21E+01 9.05E+01 Dose (krad(Si)) 20 30 9.20E+01 9.20E+01 8.42E+01 8.42E+01 8.71E+01 8.71E+01 1.02E+02 1.03E+02 9.28E+01 9.30E+01 8.42E+01 8.42E+01 9.90E+01 9.90E+01 9.04E+01 9.03E+01 9.57E+01 9.56E+01 9.49E+01 9.47E+01 9.19E+01 9.20E+01 9.06E+01 9.06E+01 50 9.19E+01 8.43E+01 8.70E+01 1.03E+02 9.29E+01 8.41E+01 9.92E+01 9.02E+01 9.55E+01 9.45E+01 9.20E+01 9.06E+01 9.17E+01 6.87E+00 1.11E+02 7.28E+01 9.18E+01 7.06E+00 1.11E+02 7.24E+01 9.17E+01 6.96E+00 1.11E+02 7.26E+01 9.18E+01 7.01E+00 1.11E+02 7.25E+01 9.18E+01 7.07E+00 1.11E+02 7.24E+01 9.29E+01 5.58E+00 1.08E+02 7.76E+01 7.60E+01 PASS 9.29E+01 5.67E+00 1.08E+02 7.73E+01 7.00E+01 PASS 9.28E+01 5.70E+00 1.08E+02 7.72E+01 7.00E+01 PASS 9.28E+01 5.71E+00 1.08E+02 7.71E+01 7.00E+01 PASS 9.27E+01 5.76E+00 1.09E+02 7.69E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 348 CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.00E+02 9.00E+01 8.00E+01 7.00E+01 6.00E+01 5.00E+01 4.00E+01 3.00E+01 2.00E+01 1.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.169. Plot of CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 349 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.169. Raw data for CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 9.13E+01 8.41E+01 8.84E+01 8.91E+01 1.15E+02 9.13E+01 9.38E+01 9.16E+01 9.99E+01 8.67E+01 8.82E+01 9.48E+01 Total 10 9.06E+01 8.43E+01 8.86E+01 8.90E+01 1.12E+02 9.16E+01 9.36E+01 9.17E+01 9.96E+01 8.68E+01 8.82E+01 9.48E+01 Dose (krad(Si)) 20 30 9.07E+01 9.06E+01 8.43E+01 8.42E+01 8.86E+01 8.87E+01 8.90E+01 8.89E+01 1.11E+02 1.09E+02 9.17E+01 9.17E+01 9.35E+01 9.34E+01 9.17E+01 9.16E+01 9.95E+01 9.95E+01 8.67E+01 8.67E+01 8.81E+01 8.81E+01 9.47E+01 9.48E+01 50 9.10E+01 8.43E+01 8.89E+01 8.89E+01 1.07E+02 9.17E+01 9.33E+01 9.16E+01 9.91E+01 8.68E+01 8.81E+01 9.48E+01 9.36E+01 1.24E+01 1.28E+02 5.96E+01 9.29E+01 1.09E+01 1.23E+02 6.29E+01 9.28E+01 1.07E+01 1.22E+02 6.35E+01 9.22E+01 9.45E+00 1.18E+02 6.63E+01 9.20E+01 8.80E+00 1.16E+02 6.79E+01 9.27E+01 4.80E+00 1.06E+02 7.95E+01 7.50E+01 PASS 9.26E+01 4.64E+00 1.05E+02 7.99E+01 7.00E+01 PASS 9.26E+01 4.59E+00 1.05E+02 8.00E+01 7.00E+01 PASS 9.26E+01 4.63E+00 1.05E+02 7.99E+01 7.00E+01 PASS 9.25E+01 4.44E+00 1.05E+02 8.03E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 350 CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.170. Plot of CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 351 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.170. Raw data for CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 9.53E+01 9.23E+01 1.06E+02 9.47E+01 1.12E+02 8.79E+01 9.00E+01 9.47E+01 8.46E+01 1.03E+02 1.05E+02 8.94E+01 Total 10 9.62E+01 9.29E+01 1.05E+02 9.35E+01 1.11E+02 8.79E+01 9.02E+01 9.45E+01 8.46E+01 1.04E+02 1.04E+02 8.96E+01 Dose (krad(Si)) 20 30 9.72E+01 9.62E+01 9.34E+01 9.35E+01 1.04E+02 1.04E+02 9.44E+01 9.45E+01 1.12E+02 1.10E+02 8.81E+01 8.79E+01 9.04E+01 9.01E+01 9.43E+01 9.49E+01 8.46E+01 8.45E+01 1.03E+02 1.02E+02 1.05E+02 1.06E+02 8.94E+01 8.94E+01 50 9.60E+01 9.35E+01 1.04E+02 9.45E+01 1.09E+02 8.79E+01 9.00E+01 9.48E+01 8.45E+01 1.02E+02 1.06E+02 8.93E+01 1.00E+02 8.37E+00 1.23E+02 7.70E+01 9.96E+01 7.77E+00 1.21E+02 7.83E+01 1.00E+02 7.69E+00 1.21E+02 7.90E+01 9.96E+01 7.02E+00 1.19E+02 8.03E+01 9.94E+01 6.87E+00 1.18E+02 8.05E+01 9.21E+01 7.26E+00 1.12E+02 7.22E+01 7.50E+01 PASS 9.23E+01 7.49E+00 1.13E+02 7.17E+01 7.00E+01 PASS 9.21E+01 7.04E+00 1.11E+02 7.28E+01 7.00E+01 PASS 9.19E+01 6.83E+00 1.11E+02 7.32E+01 7.00E+01 PASS 9.18E+01 6.78E+00 1.10E+02 7.33E+01 7.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 352 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.171. Plot of Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 353 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.171. Raw data for Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.09E+02 1.22E+02 1.14E+02 1.20E+02 1.12E+02 1.44E+02 1.10E+02 1.08E+02 1.13E+02 1.17E+02 1.16E+02 1.13E+02 Total 10 1.09E+02 1.23E+02 1.14E+02 1.21E+02 1.13E+02 1.42E+02 1.10E+02 1.08E+02 1.13E+02 1.17E+02 1.16E+02 1.14E+02 Dose (krad(Si)) 20 30 1.09E+02 1.09E+02 1.23E+02 1.23E+02 1.14E+02 1.14E+02 1.22E+02 1.21E+02 1.13E+02 1.13E+02 1.43E+02 1.45E+02 1.10E+02 1.10E+02 1.08E+02 1.08E+02 1.13E+02 1.13E+02 1.17E+02 1.17E+02 1.16E+02 1.16E+02 1.13E+02 1.14E+02 50 1.09E+02 1.23E+02 1.14E+02 1.22E+02 1.13E+02 1.44E+02 1.10E+02 1.08E+02 1.13E+02 1.17E+02 1.16E+02 1.14E+02 1.16E+02 5.29E+00 1.30E+02 1.01E+02 1.16E+02 5.57E+00 1.31E+02 1.01E+02 1.16E+02 5.77E+00 1.32E+02 1.00E+02 1.16E+02 5.64E+00 1.31E+02 1.01E+02 1.16E+02 5.87E+00 1.32E+02 1.00E+02 1.18E+02 1.48E+01 1.59E+02 7.77E+01 8.80E+01 PASS 1.18E+02 1.38E+01 1.56E+02 8.02E+01 8.80E+01 PASS 1.18E+02 1.42E+01 1.57E+02 7.91E+01 8.80E+01 PASS 1.19E+02 1.51E+01 1.60E+02 7.72E+01 8.80E+01 PASS 1.19E+02 1.49E+01 1.59E+02 7.77E+01 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 354 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.172. Plot of Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 355 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.172. Raw data for Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.18E+02 1.22E+02 1.14E+02 1.16E+02 1.17E+02 1.10E+02 1.38E+02 1.15E+02 1.14E+02 1.21E+02 1.15E+02 1.17E+02 Total 10 1.17E+02 1.23E+02 1.14E+02 1.16E+02 1.18E+02 1.10E+02 1.40E+02 1.14E+02 1.14E+02 1.21E+02 1.15E+02 1.17E+02 Dose (krad(Si)) 20 30 1.18E+02 1.18E+02 1.22E+02 1.23E+02 1.14E+02 1.14E+02 1.15E+02 1.15E+02 1.17E+02 1.18E+02 1.10E+02 1.10E+02 1.38E+02 1.37E+02 1.15E+02 1.14E+02 1.14E+02 1.14E+02 1.21E+02 1.21E+02 1.15E+02 1.15E+02 1.17E+02 1.17E+02 50 1.18E+02 1.23E+02 1.14E+02 1.15E+02 1.18E+02 1.10E+02 1.42E+02 1.15E+02 1.14E+02 1.21E+02 1.15E+02 1.17E+02 1.17E+02 3.09E+00 1.26E+02 1.09E+02 1.17E+02 3.26E+00 1.26E+02 1.08E+02 1.17E+02 3.26E+00 1.26E+02 1.08E+02 1.17E+02 3.37E+00 1.27E+02 1.08E+02 1.18E+02 3.33E+00 1.27E+02 1.08E+02 1.20E+02 1.13E+01 1.50E+02 8.87E+01 8.80E+01 PASS 1.20E+02 1.19E+01 1.53E+02 8.71E+01 8.80E+01 PASS 1.20E+02 1.13E+01 1.51E+02 8.86E+01 8.80E+01 PASS 1.19E+02 1.06E+01 1.48E+02 9.02E+01 8.80E+01 PASS 1.20E+02 1.26E+01 1.55E+02 8.56E+01 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 356 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.173. Plot of Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 357 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.173. Raw data for Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.17E+02 1.20E+02 1.16E+02 1.16E+02 1.10E+02 1.13E+02 1.16E+02 1.10E+02 1.17E+02 1.19E+02 1.09E+02 1.21E+02 Total 10 1.17E+02 1.20E+02 1.17E+02 1.16E+02 1.10E+02 1.13E+02 1.16E+02 1.10E+02 1.17E+02 1.19E+02 1.09E+02 1.21E+02 Dose (krad(Si)) 20 30 1.20E+02 1.18E+02 1.20E+02 1.21E+02 1.16E+02 1.16E+02 1.16E+02 1.16E+02 1.10E+02 1.10E+02 1.13E+02 1.13E+02 1.16E+02 1.17E+02 1.10E+02 1.10E+02 1.17E+02 1.17E+02 1.19E+02 1.19E+02 1.09E+02 1.09E+02 1.21E+02 1.21E+02 50 1.17E+02 1.21E+02 1.16E+02 1.16E+02 1.10E+02 1.13E+02 1.16E+02 1.10E+02 1.17E+02 1.19E+02 1.09E+02 1.21E+02 1.16E+02 3.69E+00 1.26E+02 1.06E+02 1.16E+02 3.64E+00 1.26E+02 1.06E+02 1.16E+02 4.03E+00 1.27E+02 1.05E+02 1.16E+02 3.81E+00 1.27E+02 1.06E+02 1.16E+02 3.71E+00 1.26E+02 1.06E+02 1.15E+02 3.50E+00 1.25E+02 1.06E+02 8.80E+01 PASS 1.15E+02 3.46E+00 1.25E+02 1.06E+02 8.80E+01 PASS 1.15E+02 3.43E+00 1.25E+02 1.06E+02 8.80E+01 PASS 1.15E+02 3.52E+00 1.25E+02 1.06E+02 8.80E+01 PASS 1.15E+02 3.46E+00 1.25E+02 1.06E+02 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 358 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.174. Plot of Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 359 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.174. Raw data for Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.25E+02 1.19E+02 1.19E+02 1.10E+02 1.17E+02 1.21E+02 1.11E+02 1.30E+02 1.16E+02 1.10E+02 1.07E+02 1.14E+02 Total 10 1.25E+02 1.19E+02 1.20E+02 1.10E+02 1.18E+02 1.21E+02 1.11E+02 1.30E+02 1.16E+02 1.10E+02 1.07E+02 1.14E+02 Dose (krad(Si)) 20 30 1.25E+02 1.24E+02 1.19E+02 1.20E+02 1.19E+02 1.20E+02 1.10E+02 1.10E+02 1.17E+02 1.17E+02 1.21E+02 1.21E+02 1.11E+02 1.11E+02 1.30E+02 1.30E+02 1.16E+02 1.16E+02 1.10E+02 1.10E+02 1.07E+02 1.07E+02 1.14E+02 1.13E+02 50 1.25E+02 1.19E+02 1.20E+02 1.10E+02 1.17E+02 1.21E+02 1.11E+02 1.30E+02 1.16E+02 1.10E+02 1.07E+02 1.14E+02 1.18E+02 5.27E+00 1.33E+02 1.04E+02 1.18E+02 5.36E+00 1.33E+02 1.04E+02 1.18E+02 5.38E+00 1.33E+02 1.03E+02 1.18E+02 5.08E+00 1.32E+02 1.04E+02 1.18E+02 5.30E+00 1.33E+02 1.04E+02 1.18E+02 8.33E+00 1.41E+02 9.49E+01 8.80E+01 PASS 1.18E+02 8.08E+00 1.40E+02 9.56E+01 8.80E+01 PASS 1.18E+02 8.16E+00 1.40E+02 9.54E+01 8.80E+01 PASS 1.18E+02 8.04E+00 1.40E+02 9.55E+01 8.80E+01 PASS 1.18E+02 8.11E+00 1.40E+02 9.54E+01 8.80E+01 PASS An ISO 9001:2008 and DSCC Certified Company 360 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.175. Plot of PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 361 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.175. Raw data for PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V Device 284 303 314 331 368 404 445 474 500 518 524 558 0 1.11E+02 1.31E+02 1.21E+02 1.13E+02 1.20E+02 1.22E+02 1.04E+02 1.09E+02 1.23E+02 1.15E+02 1.11E+02 1.41E+02 Biased Statistics Average Biased 1.19E+02 Std Dev Biased 7.98E+00 Ps90%/90% (+KTL) Biased 1.41E+02 Ps90%/90% (-KTL) Biased 9.74E+01 Un-Biased Statistics Average Un-Biased 1.15E+02 Std Dev Un-Biased 7.97E+00 Ps90%/90% (+KTL) Un-Biased 1.37E+02 Ps90%/90% (-KTL) Un-Biased 9.28E+01 Specification MIN 8.20E+01 Status PASS Total 10 1.11E+02 1.29E+02 1.21E+02 1.13E+02 1.21E+02 1.22E+02 1.04E+02 1.09E+02 1.23E+02 1.16E+02 1.11E+02 1.56E+02 Dose (krad(Si)) 20 30 1.11E+02 1.11E+02 1.29E+02 1.30E+02 1.21E+02 1.21E+02 1.13E+02 1.13E+02 1.21E+02 1.20E+02 1.22E+02 1.21E+02 1.04E+02 1.05E+02 1.09E+02 1.09E+02 1.23E+02 1.23E+02 1.16E+02 1.16E+02 1.11E+02 1.11E+02 1.39E+02 1.35E+02 50 1.11E+02 1.29E+02 1.21E+02 1.13E+02 1.21E+02 1.22E+02 1.05E+02 1.09E+02 1.23E+02 1.15E+02 1.11E+02 1.38E+02 1.19E+02 7.33E+00 1.39E+02 9.90E+01 1.19E+02 7.11E+00 1.38E+02 9.94E+01 1.19E+02 7.44E+00 1.39E+02 9.87E+01 1.19E+02 7.14E+00 1.38E+02 9.93E+01 1.15E+02 8.01E+00 1.37E+02 9.29E+01 8.20E+01 PASS 1.15E+02 7.88E+00 1.36E+02 9.31E+01 8.20E+01 PASS 1.15E+02 7.87E+00 1.36E+02 9.31E+01 8.20E+01 PASS 1.15E+02 7.84E+00 1.36E+02 9.32E+01 8.20E+01 PASS An ISO 9001:2008 and DSCC Certified Company 362 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V 1.60E+02 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.176. Plot of PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 363 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.176. Raw data for PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V Device 284 303 314 331 368 404 445 474 500 518 524 558 0 1.59E+02 1.33E+02 1.26E+02 1.42E+02 1.15E+02 1.19E+02 1.17E+02 1.19E+02 1.25E+02 1.33E+02 1.15E+02 1.13E+02 Biased Statistics Average Biased 1.35E+02 Std Dev Biased 1.67E+01 Ps90%/90% (+KTL) Biased 1.81E+02 Ps90%/90% (-KTL) Biased 8.92E+01 Un-Biased Statistics Average Un-Biased 1.22E+02 Std Dev Un-Biased 6.68E+00 Ps90%/90% (+KTL) Un-Biased 1.41E+02 Ps90%/90% (-KTL) Un-Biased 1.04E+02 Specification MIN 8.20E+01 Status PASS Total 10 1.76E+02 1.32E+02 1.25E+02 1.48E+02 1.15E+02 1.19E+02 1.17E+02 1.19E+02 1.25E+02 1.32E+02 1.15E+02 1.12E+02 Dose (krad(Si)) 20 30 1.32E+02 1.59E+02 1.33E+02 1.35E+02 1.26E+02 1.26E+02 1.45E+02 1.39E+02 1.15E+02 1.15E+02 1.19E+02 1.20E+02 1.17E+02 1.17E+02 1.19E+02 1.18E+02 1.25E+02 1.25E+02 1.33E+02 1.33E+02 1.15E+02 1.14E+02 1.12E+02 1.13E+02 50 1.35E+02 1.34E+02 1.26E+02 1.39E+02 1.15E+02 1.20E+02 1.17E+02 1.18E+02 1.25E+02 1.32E+02 1.15E+02 1.12E+02 1.39E+02 2.38E+01 2.05E+02 7.41E+01 1.30E+02 1.10E+01 1.61E+02 1.00E+02 1.35E+02 1.63E+01 1.79E+02 9.02E+01 1.30E+02 9.48E+00 1.56E+02 1.04E+02 1.22E+02 6.37E+00 1.40E+02 1.05E+02 8.20E+01 PASS 1.23E+02 6.58E+00 1.41E+02 1.04E+02 8.20E+01 PASS 1.23E+02 6.33E+00 1.40E+02 1.05E+02 8.20E+01 PASS 1.22E+02 6.26E+00 1.40E+02 1.05E+02 8.20E+01 PASS An ISO 9001:2008 and DSCC Certified Company 364 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Short-Circuit Current2 1 5V (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.177. Plot of +Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 365 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.177. Raw data for +Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 1 5V (A) @ VS=+5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status Total 10 -2.40E-02 -2.37E-02 -2.43E-02 -2.32E-02 -2.48E-02 -2.59E-02 -2.55E-02 -2.39E-02 -2.36E-02 -2.39E-02 -2.44E-02 -2.53E-02 0 -2.43E-02 -2.39E-02 -2.45E-02 -2.36E-02 -2.51E-02 -2.61E-02 -2.56E-02 -2.40E-02 -2.37E-02 -2.40E-02 -2.44E-02 -2.53E-02 Dose (krad(Si)) 20 30 -2.39E-02 -2.38E-02 -2.35E-02 -2.34E-02 -2.41E-02 -2.40E-02 -2.33E-02 -2.32E-02 -2.46E-02 -2.45E-02 -2.58E-02 -2.57E-02 -2.54E-02 -2.53E-02 -2.38E-02 -2.37E-02 -2.35E-02 -2.34E-02 -2.38E-02 -2.37E-02 -2.44E-02 -2.44E-02 -2.54E-02 -2.53E-02 50 -2.36E-02 -2.32E-02 -2.38E-02 -2.30E-02 -2.43E-02 -2.56E-02 -2.51E-02 -2.35E-02 -2.32E-02 -2.36E-02 -2.44E-02 -2.54E-02 -2.43E-02 -2.40E-02 -2.39E-02 -2.38E-02 -2.36E-02 5.48E-04 5.77E-04 5.32E-04 5.26E-04 5.21E-04 -2.28E-02 -2.24E-02 -2.24E-02 -2.23E-02 -2.22E-02 -2.58E-02 -2.56E-02 -2.53E-02 -2.52E-02 -2.50E-02 -2.47E-02 1.10E-03 -2.17E-02 -2.77E-02 -1.25E-02 PASS -2.45E-02 1.08E-03 -2.16E-02 -2.75E-02 -8.00E-03 PASS -2.44E-02 1.07E-03 -2.15E-02 -2.74E-02 -8.00E-03 PASS -2.44E-02 1.07E-03 -2.14E-02 -2.73E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 366 -2.42E-02 1.06E-03 -2.13E-02 -2.71E-02 -8.00E-03 PASS TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Short-Circuit Current2 2 5V (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.178. Plot of +Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 367 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.178. Raw data for +Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 2 5V (A) @ VS=+5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status Total 10 -2.43E-02 -2.39E-02 -2.59E-02 -2.31E-02 -2.47E-02 -2.53E-02 -2.42E-02 -2.46E-02 -2.39E-02 -2.39E-02 -2.45E-02 -2.62E-02 0 -2.47E-02 -2.42E-02 -2.62E-02 -2.36E-02 -2.50E-02 -2.54E-02 -2.43E-02 -2.47E-02 -2.40E-02 -2.40E-02 -2.46E-02 -2.62E-02 Dose (krad(Si)) 20 30 -2.42E-02 -2.41E-02 -2.38E-02 -2.37E-02 -2.57E-02 -2.56E-02 -2.32E-02 -2.30E-02 -2.46E-02 -2.45E-02 -2.52E-02 -2.51E-02 -2.41E-02 -2.40E-02 -2.44E-02 -2.44E-02 -2.38E-02 -2.37E-02 -2.38E-02 -2.37E-02 -2.46E-02 -2.46E-02 -2.62E-02 -2.62E-02 50 -2.39E-02 -2.35E-02 -2.54E-02 -2.29E-02 -2.43E-02 -2.50E-02 -2.38E-02 -2.42E-02 -2.36E-02 -2.36E-02 -2.46E-02 -2.62E-02 -2.47E-02 -2.44E-02 -2.43E-02 -2.42E-02 -2.40E-02 9.77E-04 1.01E-03 9.54E-04 9.51E-04 9.38E-04 -2.20E-02 -2.16E-02 -2.17E-02 -2.16E-02 -2.14E-02 -2.74E-02 -2.72E-02 -2.69E-02 -2.68E-02 -2.65E-02 -2.45E-02 5.84E-04 -2.29E-02 -2.61E-02 -1.25E-02 PASS -2.44E-02 5.84E-04 -2.28E-02 -2.60E-02 -8.00E-03 PASS -2.43E-02 5.79E-04 -2.27E-02 -2.58E-02 -8.00E-03 PASS -2.42E-02 5.85E-04 -2.26E-02 -2.58E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 368 -2.40E-02 5.98E-04 -2.24E-02 -2.57E-02 -8.00E-03 PASS TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Short-Circuit Current2 3 5V (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.179. Plot of +Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 369 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.179. Raw data for +Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 3 5V (A) @ VS=+5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status Total 10 -2.43E-02 -2.40E-02 -2.58E-02 -2.30E-02 -2.46E-02 -2.53E-02 -2.42E-02 -2.43E-02 -2.40E-02 -2.39E-02 -2.44E-02 -2.62E-02 0 -2.46E-02 -2.43E-02 -2.62E-02 -2.35E-02 -2.50E-02 -2.54E-02 -2.43E-02 -2.44E-02 -2.41E-02 -2.40E-02 -2.44E-02 -2.62E-02 Dose (krad(Si)) 20 30 -2.41E-02 -2.40E-02 -2.39E-02 -2.38E-02 -2.57E-02 -2.55E-02 -2.31E-02 -2.30E-02 -2.45E-02 -2.44E-02 -2.52E-02 -2.51E-02 -2.40E-02 -2.40E-02 -2.42E-02 -2.41E-02 -2.39E-02 -2.38E-02 -2.38E-02 -2.37E-02 -2.44E-02 -2.44E-02 -2.62E-02 -2.62E-02 50 -2.38E-02 -2.36E-02 -2.53E-02 -2.28E-02 -2.42E-02 -2.50E-02 -2.38E-02 -2.40E-02 -2.36E-02 -2.36E-02 -2.44E-02 -2.62E-02 -2.47E-02 -2.44E-02 -2.42E-02 -2.41E-02 -2.39E-02 9.85E-04 1.01E-03 9.50E-04 9.51E-04 9.40E-04 -2.20E-02 -2.16E-02 -2.16E-02 -2.15E-02 -2.14E-02 -2.74E-02 -2.71E-02 -2.68E-02 -2.67E-02 -2.65E-02 -2.44E-02 5.82E-04 -2.28E-02 -2.60E-02 -1.25E-02 PASS -2.43E-02 5.73E-04 -2.27E-02 -2.59E-02 -8.00E-03 PASS -2.42E-02 5.78E-04 -2.26E-02 -2.58E-02 -8.00E-03 PASS -2.41E-02 5.79E-04 -2.25E-02 -2.57E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 370 -2.40E-02 5.78E-04 -2.24E-02 -2.56E-02 -8.00E-03 PASS TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased +Short-Circuit Current2 4 5V (A) @ VS=+5V 0.00E+00 -5.00E-03 -1.00E-02 -1.50E-02 -2.00E-02 -2.50E-02 -3.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.180. Plot of +Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 371 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.180. Raw data for +Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). +Short-Circuit Current2 4 5V (A) @ VS=+5V Device 284 303 314 331 368 404 445 474 500 518 524 558 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status Total 10 -2.39E-02 -2.35E-02 -2.40E-02 -2.32E-02 -2.47E-02 -2.58E-02 -2.57E-02 -2.41E-02 -2.34E-02 -2.39E-02 -2.43E-02 -2.55E-02 0 -2.42E-02 -2.38E-02 -2.43E-02 -2.36E-02 -2.50E-02 -2.60E-02 -2.58E-02 -2.42E-02 -2.35E-02 -2.41E-02 -2.44E-02 -2.55E-02 Dose (krad(Si)) 20 30 -2.38E-02 -2.36E-02 -2.34E-02 -2.33E-02 -2.39E-02 -2.38E-02 -2.32E-02 -2.31E-02 -2.46E-02 -2.44E-02 -2.57E-02 -2.56E-02 -2.56E-02 -2.55E-02 -2.40E-02 -2.39E-02 -2.33E-02 -2.32E-02 -2.38E-02 -2.38E-02 -2.44E-02 -2.44E-02 -2.55E-02 -2.55E-02 50 -2.34E-02 -2.31E-02 -2.36E-02 -2.29E-02 -2.42E-02 -2.54E-02 -2.53E-02 -2.38E-02 -2.31E-02 -2.36E-02 -2.44E-02 -2.55E-02 -2.42E-02 -2.39E-02 -2.38E-02 -2.36E-02 -2.35E-02 5.34E-04 5.66E-04 5.21E-04 5.17E-04 5.04E-04 -2.27E-02 -2.23E-02 -2.23E-02 -2.22E-02 -2.21E-02 -2.57E-02 -2.54E-02 -2.52E-02 -2.51E-02 -2.48E-02 -2.47E-02 1.11E-03 -2.17E-02 -2.78E-02 -1.25E-02 PASS -2.46E-02 1.09E-03 -2.16E-02 -2.76E-02 -8.00E-03 PASS -2.45E-02 1.08E-03 -2.15E-02 -2.75E-02 -8.00E-03 PASS -2.44E-02 1.07E-03 -2.14E-02 -2.73E-02 -8.00E-03 PASS An ISO 9001:2008 and DSCC Certified Company 372 -2.42E-02 1.07E-03 -2.13E-02 -2.72E-02 -8.00E-03 PASS TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current2 1 5V (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 -1.00E-02 -2.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.181. Plot of -Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 373 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.181. Raw data for -Short-Circuit Current2 1 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Short-Circuit Current2 1 5V (A) Total Dose (krad(Si)) @ VS=+5V Device 0 10 20 30 50 284 4.82E-02 4.81E-02 4.81E-02 4.81E-02 4.77E-02 303 4.88E-02 4.88E-02 4.87E-02 4.84E-02 4.83E-02 314 4.86E-02 4.85E-02 4.83E-02 4.82E-02 4.82E-02 331 4.78E-02 4.79E-02 4.76E-02 4.77E-02 4.76E-02 368 5.02E-02 5.05E-02 5.00E-02 5.01E-02 5.00E-02 404 5.10E-02 5.12E-02 5.10E-02 5.10E-02 5.09E-02 445 5.00E-02 5.01E-02 5.02E-02 5.00E-02 5.00E-02 474 4.87E-02 4.87E-02 4.88E-02 4.87E-02 4.85E-02 500 4.79E-02 4.79E-02 4.79E-02 4.78E-02 4.77E-02 518 4.85E-02 4.85E-02 4.84E-02 4.84E-02 4.83E-02 524 4.83E-02 4.84E-02 4.81E-02 4.83E-02 4.82E-02 558 4.99E-02 5.00E-02 4.96E-02 4.98E-02 4.98E-02 Biased Statistics Average Biased 4.87E-02 4.87E-02 4.85E-02 4.85E-02 4.83E-02 Std Dev Biased 9.26E-04 1.03E-03 9.12E-04 9.53E-04 9.69E-04 Ps90%/90% (+KTL) Biased 5.12E-02 5.16E-02 5.10E-02 5.11E-02 5.10E-02 Ps90%/90% (-KTL) Biased 4.62E-02 4.59E-02 4.60E-02 4.59E-02 4.57E-02 Un-Biased Statistics Average Un-Biased 4.92E-02 4.93E-02 4.93E-02 4.92E-02 4.91E-02 Std Dev Un-Biased 1.23E-03 1.34E-03 1.28E-03 1.28E-03 1.30E-03 Ps90%/90% (+KTL) Un-Biased 5.26E-02 5.30E-02 5.28E-02 5.27E-02 5.26E-02 Ps90%/90% (-KTL) Un-Biased 4.58E-02 4.56E-02 4.57E-02 4.56E-02 4.55E-02 Specification MIN 1.25E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 374 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current2 2 5V (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 -1.00E-02 -2.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.182. Plot of -Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 375 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.182. Raw data for -Short-Circuit Current2 2 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Short-Circuit Current2 2 5V (A) Total Dose (krad(Si)) @ VS=+5V Device 0 10 20 30 50 284 4.82E-02 4.81E-02 4.81E-02 4.81E-02 4.78E-02 303 4.85E-02 4.85E-02 4.84E-02 4.83E-02 4.81E-02 314 5.05E-02 5.05E-02 5.04E-02 5.02E-02 5.01E-02 331 4.74E-02 4.75E-02 4.71E-02 4.72E-02 4.71E-02 368 4.87E-02 4.89E-02 4.85E-02 4.85E-02 4.84E-02 404 4.93E-02 4.95E-02 4.94E-02 4.93E-02 4.92E-02 445 4.82E-02 4.83E-02 4.83E-02 4.82E-02 4.81E-02 474 4.83E-02 4.82E-02 4.84E-02 4.82E-02 4.81E-02 500 4.77E-02 4.77E-02 4.77E-02 4.76E-02 4.75E-02 518 4.78E-02 4.78E-02 4.77E-02 4.77E-02 4.76E-02 524 4.79E-02 4.81E-02 4.78E-02 4.79E-02 4.79E-02 558 4.96E-02 4.98E-02 4.94E-02 4.95E-02 4.95E-02 Biased Statistics Average Biased 4.87E-02 4.87E-02 4.85E-02 4.85E-02 4.83E-02 Std Dev Biased 1.13E-03 1.14E-03 1.17E-03 1.11E-03 1.12E-03 Ps90%/90% (+KTL) Biased 5.17E-02 5.18E-02 5.17E-02 5.15E-02 5.14E-02 Ps90%/90% (-KTL) Biased 4.56E-02 4.56E-02 4.53E-02 4.54E-02 4.52E-02 Un-Biased Statistics Average Un-Biased 4.82E-02 4.83E-02 4.83E-02 4.82E-02 4.81E-02 Std Dev Un-Biased 6.15E-04 7.23E-04 6.83E-04 6.68E-04 6.52E-04 Ps90%/90% (+KTL) Un-Biased 4.99E-02 5.03E-02 5.02E-02 5.00E-02 4.99E-02 Ps90%/90% (-KTL) Un-Biased 4.66E-02 4.63E-02 4.64E-02 4.64E-02 4.63E-02 Specification MIN 1.25E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 376 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current2 3 5V (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 -1.00E-02 -2.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.183. Plot of -Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 377 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.183. Raw data for -Short-Circuit Current2 3 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Short-Circuit Current2 3 5V (A) Total Dose (krad(Si)) @ VS=+5V Device 0 10 20 30 50 284 4.89E-02 4.88E-02 4.89E-02 4.88E-02 4.85E-02 303 4.92E-02 4.91E-02 4.90E-02 4.89E-02 4.87E-02 314 5.13E-02 5.13E-02 5.11E-02 5.11E-02 5.10E-02 331 4.82E-02 4.82E-02 4.79E-02 4.79E-02 4.79E-02 368 4.93E-02 4.95E-02 4.92E-02 4.92E-02 4.91E-02 404 5.01E-02 5.04E-02 5.02E-02 5.01E-02 5.00E-02 445 4.89E-02 4.91E-02 4.92E-02 4.90E-02 4.89E-02 474 4.90E-02 4.89E-02 4.91E-02 4.89E-02 4.88E-02 500 4.86E-02 4.85E-02 4.87E-02 4.85E-02 4.84E-02 518 4.85E-02 4.85E-02 4.84E-02 4.83E-02 4.83E-02 524 4.87E-02 4.88E-02 4.85E-02 4.87E-02 4.87E-02 558 5.03E-02 5.05E-02 5.01E-02 5.02E-02 5.02E-02 Biased Statistics Average Biased 4.94E-02 4.94E-02 4.92E-02 4.92E-02 4.90E-02 Std Dev Biased 1.17E-03 1.19E-03 1.14E-03 1.15E-03 1.17E-03 Ps90%/90% (+KTL) Biased 5.26E-02 5.26E-02 5.24E-02 5.23E-02 5.22E-02 Ps90%/90% (-KTL) Biased 4.61E-02 4.61E-02 4.61E-02 4.60E-02 4.59E-02 Un-Biased Statistics Average Un-Biased 4.90E-02 4.91E-02 4.91E-02 4.90E-02 4.89E-02 Std Dev Un-Biased 6.15E-04 7.51E-04 6.72E-04 7.06E-04 6.83E-04 Ps90%/90% (+KTL) Un-Biased 5.07E-02 5.12E-02 5.09E-02 5.09E-02 5.07E-02 Ps90%/90% (-KTL) Un-Biased 4.73E-02 4.70E-02 4.73E-02 4.70E-02 4.70E-02 Specification MIN 1.25E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 378 TID Report 12-370 130125 R1.1 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased -Short-Circuit Current2 4 5V (A) @ VS=+5V 6.00E-02 5.00E-02 4.00E-02 3.00E-02 2.00E-02 1.00E-02 0.00E+00 -1.00E-02 -2.00E-02 0 10 20 30 40 50 Total Dose (krad(Si)) Figure 5.184. Plot of -Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 379 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.184. Raw data for -Short-Circuit Current2 4 5V (A) @ VS=+5V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). -Short-Circuit Current2 4 5V (A) Total Dose (krad(Si)) @ VS=+5V Device 0 10 20 30 50 284 4.78E-02 4.77E-02 4.78E-02 4.77E-02 4.74E-02 303 4.82E-02 4.82E-02 4.81E-02 4.79E-02 4.78E-02 314 4.81E-02 4.81E-02 4.78E-02 4.78E-02 4.77E-02 331 4.74E-02 4.75E-02 4.71E-02 4.72E-02 4.71E-02 368 4.96E-02 4.99E-02 4.94E-02 4.95E-02 4.94E-02 404 5.02E-02 5.04E-02 5.03E-02 5.02E-02 5.01E-02 445 4.95E-02 4.96E-02 4.96E-02 4.95E-02 4.94E-02 474 4.82E-02 4.82E-02 4.83E-02 4.82E-02 4.81E-02 500 4.75E-02 4.75E-02 4.75E-02 4.74E-02 4.73E-02 518 4.81E-02 4.81E-02 4.79E-02 4.79E-02 4.78E-02 524 4.77E-02 4.79E-02 4.76E-02 4.77E-02 4.77E-02 558 4.93E-02 4.94E-02 4.90E-02 4.93E-02 4.91E-02 Biased Statistics Average Biased 4.82E-02 4.82E-02 4.81E-02 4.80E-02 4.79E-02 Std Dev Biased 8.43E-04 9.52E-04 8.51E-04 8.74E-04 8.84E-04 Ps90%/90% (+KTL) Biased 5.05E-02 5.09E-02 5.04E-02 5.04E-02 5.03E-02 Ps90%/90% (-KTL) Biased 4.59E-02 4.56E-02 4.57E-02 4.56E-02 4.55E-02 Un-Biased Statistics Average Un-Biased 4.87E-02 4.88E-02 4.87E-02 4.86E-02 4.85E-02 Std Dev Un-Biased 1.12E-03 1.23E-03 1.18E-03 1.19E-03 1.18E-03 Ps90%/90% (+KTL) Un-Biased 5.18E-02 5.21E-02 5.20E-02 5.19E-02 5.18E-02 Ps90%/90% (-KTL) Un-Biased 4.56E-02 4.54E-02 4.55E-02 4.54E-02 4.53E-02 Specification MIN 1.25E-02 -8.00E-03 -8.00E-03 -8.00E-03 -8.00E-03 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 380 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 6.0. Summary / Conclusions The total ionizing dose testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose (TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead, during the radiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 300rad(Si)/s, determined by the distance from the source. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the total ionizing dose test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. Based on this criterion the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp (from the lot date code identified on the first page of this test report) PASSED the total ionizing dose test to the maximum tested dose level of 50krad(Si) with all parameters remaining within their datasheet specifications. Further, the data in this report can be analyzed along with the low dose rate report titled "Enhanced Low Dose Rate Sensitivity (ELDRS) Radiation Testing of the RH1499MW Quad Rail-toRail Input and Output Precision C-Load Op Amp for Linear Technology" to demonstrate that these parts do not exhibit ELDRS as defined in the current test method. An ISO 9001:2008 and DSCC Certified Company 381 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix A: Photograph of a Sample Unit-Under-Test to Show Part Traceability An ISO 9001:2008 and DSCC Certified Company 382 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix B: Radiation Bias Connections and Absolute Maximum Ratings TID Radiation Biased Conditions: Extracted from Linear Technology RH1499M datasheet, ID No 66-10-1499. Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Function OUT A -INPUT A +INPUT A V+ +INPUT B -INPUT B OUT B OUT C -INPUT C +INPUT C V+INPUT D -INPUT D OUT D Connection / Bias To Pin 2 via 5kΩ & 40pF, in Parallel To Pin 1 via 5kΩ & 40pF, in Parallel To 8V via 5kΩ Resistor To +15V using 0.1µF Decoupling To 8V via 5kΩ Resistor To Pin 7 via 5kΩ & 40pF, in Parallel To Pin 6 via 5kΩ & 40pF, in Parallel To Pin 9 via 5kΩ & 40pF, in Parallel To Pin 8 via 5kΩ & 40pF, in Parallel To 8V via 5kΩ Resistor To -15V using 0.1µF Decoupling To 8V via 10kΩ Resistor To Pin 14 via 5kΩ & 40pF, in Parallel To Pin 13 via 5kΩ & 40pF, in Parallel Figure B.1. Irradiation bias circuit. This figure was extracted from Linear Technology RH1499M datasheet, ID No 66-10-1499. An ISO 9001:2008 and DSCC Certified Company 383 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Radiation Unbiased Conditions: Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Function OUT A -INPUT A +INPUT A V+ +INPUT B -INPUT B OUT B OUT C -INPUT C +INPUT C V+INPUT D -INPUT D OUT D Connection / Bias GND GND GND GND GND GND GND GND GND GND GND GND GND GND Figure B.2. W package drawing (for reference only). This figure was extracted from Linear Technology RH1499M datasheet, ID No 66-10-1499. Absolute Maximum Ratings: Parameter Total Supply Voltage (V+ to V-) Input Current Output Short-Circuit Duration Max Rating 36V ±10mA Continuous An ISO 9001:2008 and DSCC Certified Company 384 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix C: Electrical Test Parameters and Conditions The expected ranges of values as well as the measurement conditions are taken from Linear Technology RH1499M datasheet. All electrical tests for this device are performed on one of Aeroflex RAD's LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that provides parameter measurements for a variety of digital, analog and mixed signal products including voltage regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System achieves accuracy and sensitivity through the use of software self-calibration and an internal relay matrix with separate family boards and custom personality adapter boards. The tester uses this relay matrix to connect the required test circuits, select the appropriate voltage / current sources and establish the needed measurement loops for all the tests performed. The measured parameters and test conditions are shown in Table C.1. A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020 for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90 KTL statistics were applied to the measured standard deviation to generate the final measurement range. This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020 mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the measurement resolution is limited by the internal DACs, which results in a measured standard deviation of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC. Note that the testing and statistics used in this document are based on an “analysis of variables” technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p. 91 for a discussion of statistical treatments). Not all measured parameters are well suited to this approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify these parameters using an “attributes” approach. An ISO 9001:2008 and DSCC Certified Company 385 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.1. Measured parameters and test conditions for the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp. Parameter Symbol Test Conditions +Supply Current 15V (A) +ICC15 VS=+/-15V -Supply Current 15V (A) -IEE15 VS=+/-15V Input Offset Voltage1 15V (V) VOS1_14 15V VS=+/-15V, VCM=0V Input Offset Current1 15V (A) IOS1_14 15V VS=+/-15V, VCM=0V +Input Bias Current BIAS1 15V (A) +IBIAS1_14 15V VS=+/-15V, VCM=0V -Input Bias Current BIAS1 15V (A) -IBIAS1_14 15V VS=+/-15V, VCM=0V Input Offset Voltage2 15V (V) VOS2_14 15V VS=+/-15V, VCM=15V Input Offset Current2 15V (A) IOS2_14 15V VS=+/-15V, VCM=15V +Input Bias Current BIAS2 15V (A) +IBIAS2_14 15V VS=+/-15V, VCM=15V -Input Bias Current BIAS2 15V (A) -IBIAS2_14 15V VS=+/-15V, VCM=15V Input Offset Voltage3 15V (V) VOS3_14 15V VS=+/-15V, VCM=-15V Input Offset Current3 15V (A) IOS3_14 15V VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 15V (A) +IBIAS3_14 15V VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 15V (A) -IBIAS3_14 15V VS=+/-15V, VCM=-15V Output Voltage Swing High1 15V (V) +VOUT1_14 15V VS=+/-15V IL=0mA Output Voltage Swing High2 15V (V) +VOUT2_14 15V VS=+/-15V IL=1mA Output Voltage Swing High3 15V (V) +VOUT3_14 15V VS=+/-15V IL=10mA Output Voltage Swing Low1 15V (V) -VOUT1_14 15V VS=+/-15V IL=0mA Output Voltage Swing Low2 15V (V) -VOUT2_14 15V VS=+/-15V IL=1mA Output Voltage Swing Low3 15V (V) -VOUT3_14 15V VS=+/-15V IL=10mA Large Signal Voltage Gain1 15V (V/mV) AVOL1_14 15V VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain2 15V (V/mV) AVOL2_14 15V VO=+/-10V, RL=2kΩ Common Mode Rejection Ratio1 15V (dB) CMRR1_14 15V VS=+/-15V, VCM=+/-15V CMRR Match1 1 to 4 15V (dB) CMRR1 MATCH 1 to 4 15V VS=+/-15V, VCM=+/-15V CMRR Match1 2 to 3 15V (dB) CMRR1 MATCH 2 to 3 15V VS=+/-15V, VCM=+/-15V Power Supply Rejection Ratio1 (dB) PSRR1_14 VS=+/-2V to +/-16V PSRR Match1 1 to 4 (dB) PSRR1 MATCH 1 to 4 VS=+/-2V to +/-16V PSRR Match1 2 to 3 (dB) PSRR1 MATCH 2 to 3 VS=+/-2V to +/-16V An ISO 9001:2008 and DSCC Certified Company 386 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 +Short-Circuit Current1 15V (A) +ISC1_14 15V VS=+/-15V, VOUT=0V -Short-Circuit Current1 15V (A) -ISC1_14 15V VS=+/-15V, VOUT=0V +Supply Current 5V (A) +ICC5 VS=+5V -Supply Current 5V (A) -IEE5 VS=+5V Input Offset Voltage4 5V (V) VOS4_14 5V VS=+5V, VCM=0V Input Offset Current4 5V (A) IOS4_14 5V VS=+5V, VCM=0V +Input Bias Current BIAS4 5V (A) +IBIAS4_14 5V VS=+5V, VCM=0V -Input Bias Current BIAS4 5V (A) -IBIAS4_14 5V VS=+5V, VCM=0V Input Offset Voltage5 5V (V) VOS5_14 5V VS=+5V, VCM=5V Input Offset Current5 5V (A) IOS5_14 5V VS=+5V, VCM=5V +Input Bias Current BIAS5 5V (A) +IBIAS5_14 5V VS=+5V, VCM=5V -Input Bias Current BIAS5 5V (A) -IBIAS5_14 5V VS=+5V, VCM=5V Output Voltage Swing High4 5V (V) +VOUT4_14 5V VS=+5V IL=0mA Output Voltage Swing High5 5V (V) +VOUT5_14 5V VS=+5V IL=1mA Output Voltage Swing High6 5V (V) +VOUT6_14 5V VS=+5V IL=2.5mA Output Voltage Swing Low4 5V (V) -VOUT4_14 5V VS=+5V IL=0mA Output Voltage Swing Low5 5V (V) -VOUT5_14 5V VS=+5V IL=1mA Output Voltage Swing Low6 5V (V) -VOUT6_14 5V VS=+5V IL=2.5mA Large Signal Voltage Gain3 5V (V/mV) AVOL3_14 5V VO=75mV to 4.8V, RL=10kΩ Common Mode Rejection Ratio2 5V (dB) CMRR2_14 5V VS=+5V, VCM=0 to +5V CMRR Match2 1 to 4 5V (dB) CMRR2 MATCH 1 to 4 5V VS=+5V, VCM=0 to +5V CMRR Match2 2 to 3 5V (dB) CMRR2 MATCH 2 to 3 5V VS=+5V, VCM=0 to +5V Power Supply Rejection Ratio2 (dB) PSRR2_14 VS=+4.5V to +12V PSRR Match2 1 to 4 (dB) PSRR2 MATCH 1 to 4 VS=+4.5V to +12V PSRR Match2 2 to 3 (dB) PSRR2 MATCH 2 to 3 VS=+4.5V to +12V +Short-Circuit Current2 5V (A) +ISC2_14 5V VS=+5V -Short-Circuit Current2 5V (A) -ISC2_14 5V VS=+5V Gain-Bandwidth Product 15V (MHz) GBW_14 15V +Slew Rate 15V (V/us) +SR_14 5V -Slew Rate 15V (V/us) -SR_14 5V VS=+/-15V, f=100kHz VS=+/-15V, AV=-1, RL=10K, VO=+/-10V VS=+/-15V, AV=-1, RL=10K, VO=+/-10V An ISO 9001:2008 and DSCC Certified Company 387 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH1499MW Quad Rail-to-Rail Input and Output Precision C-Load Op Amp. Pre-Irradiation Specification MIN MAX Parameter +Supply Current 15V (A) 1.00E-02 Measurement Precision/Resolution ±1.64E-04 -Supply Current 15V (A) -1.00E-02 ±1.61E-04 Input Offset Voltage1 15V (V) -8.00E-04 8.00E-04 ±2.51E-05 Input Offset Current1 15V (A) -7.00E-08 7.00E-08 ±9.10E-10 +Input Bias Current BIAS1 15V (A) -7.15E-07 7.15E-07 ±1.22E-08 -Input Bias Current BIAS1 15V (A) -7.15E-07 7.15E-07 ±1.13E-08 Input Offset Voltage2 15V (V) -8.00E-04 8.00E-04 ±1.28E-05 Input Offset Current2 15V (A) -7.00E-08 7.00E-08 ±9.67E-10 +Input Bias Current BIAS2 15V (A) -7.15E-07 7.15E-07 ±7.21E-09 -Input Bias Current BIAS2 15V (A) -7.15E-07 7.15E-07 ±6.44E-09 Input Offset Voltage3 15V (V) -8.00E-04 8.00E-04 ±1.65E-05 Input Offset Current3 15V (A) -7.00E-08 7.00E-08 ±7.00E-10 +Input Bias Current BIAS3 15V (A) -7.15E-07 7.15E-07 ±1.01E-08 -Input Bias Current BIAS3 15V (A) -7.15E-07 7.15E-07 ±8.88E-09 Output Voltage Swing High1 15V (V) 1.00E-02 ±2.81E-04 Output Voltage Swing High2 15V (V) 1.50E-01 ±1.19E-03 Output Voltage Swing High3 15V (V) 8.00E-01 ±6.15E-03 Output Voltage Swing Low1 15V (V) 3.00E-02 ±5.56E-04 Output Voltage Swing Low2 15V (V) 1.00E-01 ±1.03E-03 Output Voltage Swing Low3 15V (V) 5.00E-01 ±3.44E-03 Large Signal Voltage Gain1 15V (V/mV) 1.00E+03 ±2.28E+02 Large Signal Voltage Gain2 15V (V/mV) Common Mode Rejection Ratio1 15V (dB) CMRR Match1 1 to 4 15V (dB) 5.00E+01 ±1.55E+01 9.00E+01 3.00E+02 ±9.45E-02 8.40E+01 3.00E+02 ±6.79E-02 CMRR Match1 2 to 3 15V (dB) 8.40E+01 3.00E+02 ±1.71E-01 Power Supply Rejection Ratio1 (dB) 9.00E+01 ±3.82E-01 PSRR Match1 1 to 4 (dB) 8.30E+01 ±1.35E-01 An ISO 9001:2008 and DSCC Certified Company 388 TID Report 12-370 130125 R1.1 PSRR Match1 2 to 3 (dB) 8.30E+01 +Short-Circuit Current1 15V (A) -Short-Circuit Current1 15V (A) ±8.96E-02 -1.50E-02 1.50E-02 +Supply Current 5V (A) Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 ±4.01E-04 ±6.44E-04 8.80E-03 ±8.67E-05 -Supply Current 5V (A) -8.80E-03 ±8.59E-05 Input Offset Voltage4 5V (V) -8.00E-04 8.00E-04 ±1.49E-05 Input Offset Current4 5V (A) -6.50E-08 6.50E-08 ±5.28E-10 +Input Bias Current BIAS4 5V (A) -6.50E-07 6.50E-07 ±6.11E-09 -Input Bias Current BIAS4 5V (A) -6.50E-07 6.50E-07 ±6.24E-09 Input Offset Voltage5 5V (V) -8.00E-04 8.00E-04 ±8.65E-06 Input Offset Current5 5V (A) -6.50E-08 6.50E-08 ±5.15E-10 +Input Bias Current BIAS5 5V (A) -6.50E-07 6.50E-07 ±3.27E-09 -Input Bias Current BIAS5 5V (A) -6.50E-07 6.50E-07 ±2.91E-09 Output Voltage Swing High4 5V (V) 1.00E-02 ±2.53E-04 Output Voltage Swing High5 5V (V) 1.50E-01 ±8.19E-04 Output Voltage Swing High6 5V (V) 2.50E-01 ±1.46E-03 Output Voltage Swing Low4 5V (V) 3.00E-02 ±3.86E-04 Output Voltage Swing Low5 5V (V) 1.00E-01 ±4.14E-04 Output Voltage Swing Low6 5V (V) 2.00E-01 ±7.42E-04 Large Signal Voltage Gain3 5V (V/mV) 6.00E+02 ±5.72E+02 Common Mode Rejection Ratio2 5V (dB) 7.60E+01 ±1.49E-01 CMRR Match2 1 to 4 5V (dB) 7.50E+01 ±5.95E-02 CMRR Match2 2 to 3 5V (dB) 7.50E+01 ±3.80E-01 Power Supply Rejection Ratio2 (dB) 8.80E+01 ±4.26E+00 PSRR Match2 1 to 4 (dB) 8.20E+01 ±1.05E+00 PSRR Match2 2 to 3 (dB) 8.20E+01 ±6.39E-01 +Short-Circuit Current2 5V (A) -Short-Circuit Current2 5V (A) -1.25E-02 1.25E-02 An ISO 9001:2008 and DSCC Certified Company 389 ±4.02E-05 ±4.63E-04 TID Report 12-370 130125 R1.1 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix D: List of Figures Used in the Results Section (Section 5) 5.1. 5.2. 5.3. 5.4. 5.5. 5.6. 5.7. 5.8. 5.9. 5.10. 5.11. 5.12. 5.13. 5.14. 5.15. 5.16. 5.17. 5.18. 5.19. 5.20. 5.21. 5.22. 5.23. 5.24. 5.25. 5.26. 5.27. 5.28. 5.29. 5.30. 5.31. 5.32. 5.33. 5.34. 5.35. 5.36. 5.37. 5.38. 5.39. 5.40. 5.41. 5.42. 5.43. 5.44. +Supply Current 15V (A) @ VS=+/-15V -Supply Current 15V (A) @ VS=+/-15V Input Offset Voltage1 1 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 2 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 3 15V (V) @ VS=+/-15V, VCM=0V Input Offset Voltage1 4 15V (V) @ VS=+/-15V, VCM=0V Input Offset Current1 1 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 2 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 3 15V (A) @ VS=+/-15V, VCM=0V Input Offset Current1 4 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V +Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 1 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 2 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 3 15V (A) @ VS=+/-15V, VCM=0V -Input Bias Current BIAS1 4 15V (A) @ VS=+/-15V, VCM=0V Input Offset Voltage2 1 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 2 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 3 15V (V) @ VS=+/-15V, VCM=15V Input Offset Voltage2 4 15V (V) @ VS=+/-15V, VCM=15V Input Offset Current2 1 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 2 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 3 15V (A) @ VS=+/-15V, VCM=15V Input Offset Current2 4 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V +Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 1 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 2 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 3 15V (A) @ VS=+/-15V, VCM=15V -Input Bias Current BIAS2 4 15V (A) @ VS=+/-15V, VCM=15V Input Offset Voltage3 1 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 2 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 3 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Voltage3 4 15V (V) @ VS=+/-15V, VCM=-15V Input Offset Current3 1 15V (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 2 15V (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 3 15V (A) @ VS=+/-15V, VCM=-15V Input Offset Current3 4 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V An ISO 9001:2008 and DSCC Certified Company 390 TID Report 12-370 130125 R1.1 5.45. 5.46. 5.47. 5.48. 5.49. 5.50. 5.51. 5.52. 5.53. 5.54. 5.55. 5.56. 5.57. 5.58. 5.59. 5.60. 5.61. 5.62. 5.63. 5.64. 5.65. 5.66. 5.67. 5.68. 5.69. 5.70. 5.71. 5.72. 5.73. 5.74. 5.75. 5.76. 5.77. 5.78. 5.79. 5.80. 5.81. 5.82. 5.83. 5.84. 5.85. 5.86. 5.87. 5.88. 5.89. 5.90. +Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V +Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 1 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 2 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 3 15V (A) @ VS=+/-15V, VCM=-15V -Input Bias Current BIAS3 4 15V (A) @ VS=+/-15V, VCM=-15V Output Voltage Swing High1 1 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 2 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 3 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High1 4 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing High2 1 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 2 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 3 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High2 4 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing High3 1 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 2 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 3 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing High3 4 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low1 1 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 2 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 3 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low1 4 15V (V) @ VS=+/-15V IL=0mA Output Voltage Swing Low2 1 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 2 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 3 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low2 4 15V (V) @ VS=+/-15V IL=1mA Output Voltage Swing Low3 1 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 2 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 3 15V (V) @ VS=+/-15V IL=10mA Output Voltage Swing Low3 4 15V (V) @ VS=+/-15V IL=10mA Large Signal Voltage Gain1 1 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 2 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 3 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain1 4 15V (V/mV) @ VO=+/-14.5V, RL=10kΩ Large Signal Voltage Gain2 1 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 2 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 3 15V (V/mV) @ VO=+/-10V, RL=2kΩ Large Signal Voltage Gain2 4 15V (V/mV) @ VO=+/-10V, RL=2kΩ Common Mode Rejection Ratio1 1 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 2 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Common Mode Rejection Ratio1 4 15V (dB) @ VS=+/-15V, VCM=+/-15V CMRR Match1 1 to 4 15V (dB) @ VS=+/-15V, VCM=+/-15V CMRR Match1 2 to 3 15V (dB) @ VS=+/-15V, VCM=+/-15V Power Supply Rejection Ratio1 1 (dB) @ VS=+/-2V to +/-16V Power Supply Rejection Ratio1 2 (dB) @ VS=+/-2V to +/-16V An ISO 9001:2008 and DSCC Certified Company 391 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Report 12-370 130125 R1.1 5.91. 5.92. 5.93. 5.94. 5.95. 5.96. 5.97. 5.98. 5.99. 5.100. 5.101. 5.102. 5.103. 5.104. 5.105. 5.106. 5.107. 5.108. 5.109. 5.110. 5.111. 5.112. 5.113. 5.114. 5.115. 5.116. 5.117. 5.118. 5.119. 5.120. 5.121. 5.122. 5.123. 5.124. 5.125. 5.126. 5.127. 5.128. 5.129. 5.130. 5.131. 5.132. 5.133. 5.134. 5.135. 5.136. Power Supply Rejection Ratio1 3 (dB) @ VS=+/-2V to +/-16V Power Supply Rejection Ratio1 4 (dB) @ VS=+/-2V to +/-16V PSRR Match1 1 to 4 (dB) @ VS=+/-2V to +/-16V PSRR Match1 2 to 3 (dB) @ VS=+/-2V to +/-16V +Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V +Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 1 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 2 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 3 15V (A) @ VS=+/-15V, VOUT=0V -Short-Circuit Current1 4 15V (A) @ VS=+/-15V, VOUT=0V +Supply Current 5V (A) @ VS=+5V -Supply Current 5V (A) @ VS=+5V Input Offset Voltage4 1 5V (V) @ VS=+5V, VCM=0V Input Offset Voltage4 2 5V (V) @ VS=+5V, VCM=0V Input Offset Voltage4 3 5V (V) @ VS=+5V, VCM=0V Input Offset Voltage4 4 5V (V) @ VS=+5V, VCM=0V Input Offset Current4 1 5V (A) @ VS=+5V, VCM=0V Input Offset Current4 2 5V (A) @ VS=+5V, VCM=0V Input Offset Current4 3 5V (A) @ VS=+5V, VCM=0V Input Offset Current4 4 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V +Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 1 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 2 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 3 5V (A) @ VS=+5V, VCM=0V -Input Bias Current BIAS4 4 5V (A) @ VS=+5V, VCM=0V Input Offset Voltage5 1 5V (V) @ VS=+5V, VCM=5V Input Offset Voltage5 2 5V (V) @ VS=+5V, VCM=5V Input Offset Voltage5 3 5V (V) @ VS=+5V, VCM=5V Input Offset Voltage5 4 5V (V) @ VS=+5V, VCM=5V Input Offset Current5 1 5V (A) @ VS=+5V, VCM=5V Input Offset Current5 2 5V (A) @ VS=+5V, VCM=5V Input Offset Current5 3 5V (A) @ VS=+5V, VCM=5V Input Offset Current5 4 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V +Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 1 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 2 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 3 5V (A) @ VS=+5V, VCM=5V -Input Bias Current BIAS5 4 5V (A) @ VS=+5V, VCM=5V An ISO 9001:2008 and DSCC Certified Company 392 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Report 12-370 130125 R1.1 5.137. 5.138. 5.139. 5.140. 5.141. 5.142. 5.143. 5.144. 5.145. 5.146. 5.147. 5.148. 5.149. 5.150. 5.151. 5.152. 5.153. 5.154. 5.155. 5.156. 5.157. 5.158. 5.159. 5.160. 5.161. 5.162. 5.163. 5.164. 5.165. 5.166. 5.167. 5.168. 5.169. 5.170. 5.171. 5.172. 5.173. 5.174. 5.175. 5.176. 5.177. 5.178. 5.179. 5.180. 5.181. 5.182. Output Voltage Swing High4 1 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High4 2 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High4 3 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High4 4 5V (V) @ VS=+5V IL=0mA Output Voltage Swing High5 1 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High5 2 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High5 3 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High5 4 5V (V) @ VS=+5V IL=1mA Output Voltage Swing High6 1 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 2 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 3 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing High6 4 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low4 1 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 2 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 3 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low4 4 5V (V) @ VS=+5V IL=0mA Output Voltage Swing Low5 1 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 2 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 3 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low5 4 5V (V) @ VS=+5V IL=1mA Output Voltage Swing Low6 1 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 2 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 3 5V (V) @ VS=+5V IL=2.5mA Output Voltage Swing Low6 4 5V (V) @ VS=+5V IL=2.5mA Large Signal Voltage Gain3 1 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 2 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 3 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Large Signal Voltage Gain3 4 5V (V/mV) @ VO=75mV to 4.8V, RL=10kΩ Common Mode Rejection Ratio2 1 5V (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 2 5V (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 3 5V (dB) @ VS=+5V, VCM=0 to +5V Common Mode Rejection Ratio2 4 5V (dB) @ VS=+5V, VCM=0 to +5V CMRR Match2 1 to 4 5V (dB) @ VS=+5V, VCM=0 to +5V CMRR Match2 2 to 3 5V (dB) @ VS=+5V, VCM=0 to +5V Power Supply Rejection Ratio2 1 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 2 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 3 (dB) @ VS=+4.5V to +12V Power Supply Rejection Ratio2 4 (dB) @ VS=+4.5V to +12V PSRR Match2 1 to 4 (dB) @ VS=+4.5V to +12V PSRR Match2 2 to 3 (dB) @ VS=+4.5V to +12V +Short-Circuit Current2 1 5V (A) @ VS=+5V +Short-Circuit Current2 2 5V (A) @ VS=+5V +Short-Circuit Current2 3 5V (A) @ VS=+5V +Short-Circuit Current2 4 5V (A) @ VS=+5V -Short-Circuit Current2 1 5V (A) @ VS=+5V -Short-Circuit Current2 2 5V (A) @ VS=+5V An ISO 9001:2008 and DSCC Certified Company 393 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Report 12-370 130125 R1.1 5.183. -Short-Circuit Current2 3 5V (A) @ VS=+5V 5.184. -Short-Circuit Current2 4 5V (A) @ VS=+5V An ISO 9001:2008 and DSCC Certified Company 394 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800