ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Surface Mount Diode Array Product #: SP720APP Issue Date: January 22, 2007 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Environmental Data Coordinator> (1) Parts, sub-materials and unit parts This document covers the Surface Mount Diode Array RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Form 585-047 Rev. A 1 2/21/06 Table 1: List of Raw Materials covered by this report Total Parts 1 2 3 4 5 6 Raw Material Part Number Poonsang C194 84-1LMISR4 N/A EME 6300H N/A LF720Waf Raw Material Description Leadframe Epoxy Gold Wire Molding Compound Tin Plate Die 2 Page(s) 3–4 5–8 9 – 12 13 – 15 16 – 18 19 - 22 Test Report No. F690501/LF-CTS059797 To: Date : February 16, 2006 Page 1 of 2 POONGSAN MICROTEC CORP. 52, Banyeo 1-dong, Haeundae-gu, Busan, Korea The following merchandise was submitted and identified by the client as : - Commodity : Lead Frame (Cu Alloy - C194) SGS File No. : P-48/2006-0151 Country of Origin : Korea Received Date : February 09, 2006 Test Performing Date : February 10, 2006 Test Performed : SGS Testing Korea tested the sample(s) selected by applicant with following result. Test Results : For further details, please refer to following page. Buyer(s) : LG, SAMSUNG, SANYO & SONY SGS Testing Korea Co., Ltd. SBP/mss Thomas Hwang / Lab. Manager This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This Test Report cannot be reproduced, except in full, without prior written permission of the Company. Test Report No. F690501/LF-CTS059797 Date : February 16, 2006 Page 2 of 2 Heavy Metal Test Item(s) Unit Test Method MDL Result(s) Cadmium (Cd) mg/kg USEPA 3052, ICP-AES 1 N. D. Lead (Pb) mg/kg USEPA 3052, ICP-AES 20 N. D. Mercury (Hg) mg/kg USEPA 3052, ICP-AES 2 N. D. Hexavalent Chromium (Cr VI) mg/kg USEPA 3060A, UV-vis 1 N. D. MDL Result(s) Flame Retardants Test Item(s) Unit Test Method Monobromobiphenyl mg/kg USEPA 3540C, GC/MS 5 N. D. Dibromobiphenyl mg/kg USEPA 3540C, GC/MS 5 N. D. Tribromobiphenyl mg/kg USEPA 3540C, GC/MS 5 N. D. Tetrabromobiphenyl mg/kg USEPA 3540C, GC/MS 5 N. D. Heptabromobiphenyl mg/kg USEPA 3540C, GC/MS 5 N. D. Hexabromobiphenyl mg/kg USEPA 3540C, GC/MS 5 N. D. Pentabromobiphenyl mg/kg USEPA 3540C, GC/MS 5 N. D. Octabromobiphenyl mg/kg USEPA 3540C, GC/MS 5 N. D. Nonabromobiphenyl mg/kg USEPA 3540C, GC/MS 5 N. D. Decabromobiphenyl mg/kg USEPA 3540C, GC/MS 5 N. D. Monobromobiphenyl ether mg/kg USEPA 3540C, GC/MS 5 N. D. Dibromobiphenyl ether mg/kg USEPA 3540C, GC/MS 5 N. D. Tribromobiphenyl ether mg/kg USEPA 3540C, GC/MS 5 N. D. Tetrabromobiphenyl ether mg/kg USEPA 3540C, GC/MS 5 N. D. Heptabromobiphenyl ether mg/kg USEPA 3540C, GC/MS 5 N. D. Hexabromobiphenyl ether mg/kg USEPA 3540C, GC/MS 5 N. D. Pentabromobiphenyl ether mg/kg USEPA 3540C, GC/MS 5 N. D. Octabromobiphenyl ether mg/kg USEPA 3540C, GC/MS 5 N. D. Nonabromobiphenyl ether mg/kg USEPA 3540C, GC/MS 5 N. D. Decabromobiphenyl ether mg/kg USEPA 3540C, GC/MS 5 N. D. Note : (1) N.D. = Not detected. (<MDL) (2) MDL = Method Detection Limit This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This Test Report cannot be reproduced, except in full, without prior written permission of the Company. Test Report No. F690501/LF-CTSGP06-03316 To: Date: February 20, 2006 Page 1 of 4 HERAEUS ORIENTAL HITEC CO.,LTD 587-122 Hankik-dong Nam-gu INCHEON 402-040 Korea The following merchandise was submitted and identified by the client as : Commodity : Au wire(HA6)/HP SGS File No. : GP06-03316 Received Date : February 13, 2006 Test Performing Date : February 14, 2006 Test Performed : SGS Testing Korea tested the sample(s) selected by applicant with following results Test Results : For further details, please refer to following page(s) Buyer(s) : SONY SGS Testing Korea Co. Ltd. Brendan Lee Patrick An Monet Jeong Jinee Song /Testing Person Jeff Jang / Technical Mgr Jason Han / Lab Director This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. The results shown in this test report refer only to the sample (s) tested unless otherwise stated. This Test Report cannot be reproduced, except in full, without prior written permission of the Company. Test Report No. F690501/LF-CTSGP06-03316 Sample No. : GP06-03316.001 Sample Description : Au wire(HA6)/HP Style/Item No. : N/A Comments : Material is Au. Date: February 20, 2006 Page 2 of 4 Heavy Metals Test Items Unit Test Method MDL Results Cadmium(Cd) mg/kg US EPA 3050B(1996), US EPA 6010B(1996) 0.5 N.D. Lead (Pb) mg/kg US EPA 3050B(1996), US EPA 6010B(1996) 5 N.D. Mercury (Hg) mg/kg US EPA 3052(1996), US EPA 6010B(1996) 2 N.D. Hexavalent Chromium (Cr VI) mg/kg US EPA 3060A(1996), US EPA 7196A(1992) 1 N.D. Flame Retardants-PBBs/PBDEs Test Items Unit Test Method MDL Results Monobromobiphenyl mg/kg US EPA 3540C, GC/MS 5 N.D. Dibromobiphenyl mg/kg US EPA 3540C, GC/MS 5 N.D. Tribromobiphenyl mg/kg US EPA 3540C, GC/MS 5 N.D. Tetrabromobiphenyl mg/kg US EPA 3540C, GC/MS 5 N.D. Heptabromobiphenyl mg/kg US EPA 3540C, GC/MS 5 N.D. Hexabromobiphenyl mg/kg US EPA 3540C, GC/MS 5 N.D. Pentabromobiphenyl mg/kg US EPA 3540C, GC/MS 5 N.D. Octabromobiphenyl mg/kg US EPA 3540C, GC/MS 5 N.D. Nonabromobiphenyl mg/kg US EPA 3540C, GC/MS 5 N.D. Decabromobiphenyl mg/kg US EPA 3540C, GC/MS 5 N.D. Monobromodiphenyl ether mg/kg US EPA 3540C, GC/MS 5 N.D. Dibromodiphenyl ether mg/kg US EPA 3540C, GC/MS 5 N.D. Tribromodiphenyl ether mg/kg US EPA 3540C, GC/MS 5 N.D. Tetrabromodiphenyl ether mg/kg US EPA 3540C, GC/MS 5 N.D. Heptabromodiphenyl ether mg/kg US EPA 3540C, GC/MS 5 N.D. Hexabromodiphenyl ether mg/kg US EPA 3540C, GC/MS 5 N.D. Pentabromodiphenyl ether mg/kg US EPA 3540C, GC/MS 5 N.D. Octabromodiphenyl ether mg/kg US EPA 3540C, GC/MS 5 N.D. Nonabromodiphenyl ether mg/kg US EPA 3540C, GC/MS 5 N.D. Decabromodiphenyl ether mg/kg US EPA 3540C, GC/MS 5 N.D. NOTE: (1) N.D. = Not detected.(<MDL) (2) ppm = mg/kg (3) MDL = Method Detection Limit (4) - = No regulation (5) ** = Qualitative analysis (No Unit) (6) Negative = Undetectable / Positive = Detectable This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. The results shown in this test report refer only to the sample (s) tested unless otherwise stated. This Test Report cannot be reproduced, except in full, without prior written permission of the Company. Test Report No. F690501/LF-CTSGP06-03316 Date: February 20, 2006 Page 3 of 4 Picture of Sample as Received: NOTE: (1) N.D. = Not detected.(<MDL) (2) ppm = mg/kg (3) MDL = Method Detection Limit (4) - = No regulation (5) ** = Qualitative analysis (No Unit) (6) Negative = Undetectable / Positive = Detectable This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. The results shown in this test report refer only to the sample (s) tested unless otherwise stated. This Test Report cannot be reproduced, except in full, without prior written permission of the Company. Test Report No. F690501/LF-CTSGP06-03316 Date: February 20, 2006 Page 4 of 4 Flow Chart of Digestion (EPA 3050B for Cd, Pb) Cutting/Preparation Sample Measurement (0.5g) Add HNO3 Add H2O2 Add HCl Total Digestion ICP-AES DATA The samples were dissolved totally by pre-conditioning method according to above flow chart. Operator Lauren Kim Section Chief Jeff Jang *** End *** NOTE: (1) N.D. = Not detected.(<MDL) (2) ppm = mg/kg (3) MDL = Method Detection Limit (4) - = No regulation (5) ** = Qualitative analysis (No Unit) (6) Negative = Undetectable / Positive = Detectable This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and jurisdictional issues defined therein. The results shown in this test report refer only to the sample (s) tested unless otherwise stated. This Test Report cannot be reproduced, except in full, without prior written permission of the Company. ALS TECHNICHEM (S) PTE LTD 14 Little Road, #07-01 & #08-01, Tropical Industrial Building Singapore 536987 Phone: (65) 6283 9268 Fax: (65) 6283 9689 Website: www.als.com.au ALS TECHNICHEM REPORT OUR REF NO : DATE : ATS/GENV/0575/06/lc 03 April, 2006 COMPANY : Sumitomo Bakelite Singapore Pte Ltd 1 Senoko South Road Singapore 758069 DATE SAMPLE RECEIVED : DATE ANALYSED : DATE COMPLETED : 28 March, 2006 28 March, 2006 03 April, 2006 SAMPLE DESCRIPTION : One sample was received with references :Description TEST REQUESTED : 1. 2. 3. 4. 5. 6. TEST METHOD : 1. 2. 3. 4. 5. 6. : Page 1 of 3 EME-6300 Type H To determine the Cadmium Content in submitted sample in accordance with EEC Directive 2002/95/EC. To determine the Lead Content in submitted sample in accordance with EEC Directive 2002/95/EC. To determine the Mercury Content in submitted sample in accordance with EEC Directive 2002/95/EC. To determine the Hexavalent Chromium Content in submitted sample in accordance with EEC Directive 2002/95/EC. To determine the PBB in submitted sample in accordance with EEC Directive 2002/95/EC. To determine the PBDE in submitted sample in accordance with EEC Directive 2002/95/EC. The sample was pre-conditioned with reference to EPA3050B with completely digestion. The analysis was performed by ICP-AES with reference to EPA6010. The sample was pre-conditioned with reference to EPA3050B with completely digestion. The analysis was performed by ICP-AES with reference to EPA6010. The sample was pre-conditioned with reference to EPA3052B with completely digestion. The analysis was performed by Mercury Analyzer. The sample was pre-conditioned with reference to EPA3060A. The analysis was performed by UV-VIS with reference to EPA7196A. The sample was pre-conditioned with reference to EPA 1614. The analysis was preformed by GCMS with reference to EPA1614. The sample was pre-conditioned with reference to EPA 1614. The analysis was preformed by GCMS with reference to EPA1614. … 2/- This Report shall not be reproducted except in full without prior approval of the Management This Report may not be used for advertising purposes ALS TECHNICHEM (S) PTE LTD 14 Little Road, #07-01 & #08-01, Tropical Industrial Building Singapore 536987 Phone: (65) 6283 9268 Fax: (65) 6283 9689 Website: www.als.com.au ALS TECHNICHEM OUR REF NO : DATE : COMPANY : (Continued) Description RESULTS : ATS/GENV/0575/06/lc 03 April, 2006 Sumitomo Bakelite Singapore Pte Ltd : Page 2 of 3 EME-6300 Type H On analysis and calculation from the components, the following results were obtained :- TESTS RESULTS Cadmium (Cd), ppm wt Not Detected Lead (Pb), ppm wt 3.1 Mercury (Hg), ppm wt Not Detected Hexavalent Chromium (Cr6+), ppm wt Not Detected Polybrominated biphenyls (PBB), ppm wt Not Detected Polybrominated diphenyl ethers (PBDE), ppm wt Not Detected Note : 1) ppm wt : mg/kg 2) Detection Limit : a) b) c) d) e) f) Cadmium Lead Mercury Hexavalent Chromium Polybrominated biphenyls Polybrominated diphenyl ethers : 2.0 ppm : 2.0 ppm : 2.0 ppm : 2.0 ppm : 5.0 ppm : 5.0 ppm 3) Above tests were carried out by ALS chemists: Sin Min Hong, and Geok Cheng Lee ALS TECHNICHEM (S) PTE LTD YAO KAIWEN B.SC., M.SC. This Report shall not be reproducted except in full without prior approval of the Management This Report may not be used for advertising purposes ALS TECHNICHEM (S) PTE LTD 14 Little Road, #07-01 & #08-01, Tropical Industrial Building Singapore 536987 Phone: (65) 6283 9268 Fax: (65) 6283 9689 Website: www.als.com.au ALS TECHNICHEM OUR REF NO : DATE : COMPANY : (Continued) Description ATS/GENV/0575/06/lc 03 April, 2006 Sumitomo Bakelite Singapore Pte Ltd : Page 3 of 3 EME-6300 Type H Measurement Flowchart Small size or powder by grinding, milling or cutting Sample For Cd/Pb/Hg tests Acid digestion with methods: EN1122 or EPA3050B or EPA3052 or EN13346 Homogenized test specimens For Cr(VI) test Totally dissolved Extraction with method EPA3060A Solution Residue appeared Residue Solution Residue is treated with other acids such as HF, HBF4, HClO4 or other methods such as alkali dissolution, and residue to be dissolved into solution Color development and UV-Vis measurement Combine two solutions ICP for Cd/Pb measurement and Mercury analyzer for Hg measurement This Report shall not be reproducted except in full without prior approval of the Management This Report may not be used for advertising purposes