ICPTest_SP720APP.pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
Surface Mount Diode Array
Product #:
SP720APP
Issue Date:
January 22, 2007
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive
2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Environmental Data Coordinator>
(1) Parts, sub-materials and unit parts
This document covers the Surface Mount Diode Array RoHS-Compliant series products
manufactured by Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:
Form 585-047 Rev. A
1
2/21/06
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
Raw Material Part Number
Poonsang C194
84-1LMISR4
N/A
EME 6300H
N/A
LF720Waf
Raw Material Description
Leadframe
Epoxy
Gold Wire
Molding Compound
Tin Plate
Die
2
Page(s)
3–4
5–8
9 – 12
13 – 15
16 – 18
19 - 22
Test Report No. F690501/LF-CTS059797
To:
Date : February 16, 2006
Page 1 of 2
POONGSAN MICROTEC CORP.
52, Banyeo 1-dong,
Haeundae-gu,
Busan,
Korea
The following merchandise was submitted and identified by the client as : -
Commodity
:
Lead Frame (Cu Alloy - C194)
SGS File No.
:
P-48/2006-0151
Country of Origin
:
Korea
Received Date
:
February 09, 2006
Test Performing Date
:
February 10, 2006
Test Performed
:
SGS Testing Korea tested the sample(s) selected by applicant with
following result.
Test Results
:
For further details, please refer to following page.
Buyer(s)
:
LG, SAMSUNG, SANYO & SONY
SGS Testing Korea Co., Ltd.
SBP/mss
Thomas Hwang / Lab. Manager
This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and
jurisdictional issues defined therein. The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This Test Report cannot be reproduced, except
in full, without prior written permission of the Company.
Test Report No. F690501/LF-CTS059797
Date : February 16, 2006
Page 2 of 2
Heavy Metal
Test Item(s)
Unit
Test Method
MDL
Result(s)
Cadmium (Cd)
mg/kg
USEPA 3052, ICP-AES
1
N. D.
Lead (Pb)
mg/kg
USEPA 3052, ICP-AES
20
N. D.
Mercury (Hg)
mg/kg
USEPA 3052, ICP-AES
2
N. D.
Hexavalent Chromium (Cr VI)
mg/kg
USEPA 3060A, UV-vis
1
N. D.
MDL
Result(s)
Flame Retardants
Test Item(s)
Unit
Test Method
Monobromobiphenyl
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Dibromobiphenyl
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Tribromobiphenyl
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Tetrabromobiphenyl
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Heptabromobiphenyl
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Hexabromobiphenyl
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Pentabromobiphenyl
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Octabromobiphenyl
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Nonabromobiphenyl
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Decabromobiphenyl
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Monobromobiphenyl ether
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Dibromobiphenyl ether
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Tribromobiphenyl ether
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Tetrabromobiphenyl ether
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Heptabromobiphenyl ether
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Hexabromobiphenyl ether
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Pentabromobiphenyl ether
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Octabromobiphenyl ether
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Nonabromobiphenyl ether
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Decabromobiphenyl ether
mg/kg
USEPA 3540C, GC/MS
5
N. D.
Note :
(1) N.D. = Not detected. (<MDL)
(2) MDL = Method Detection Limit
This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and
jurisdictional issues defined therein. The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This Test Report cannot be reproduced, except
in full, without prior written permission of the Company.
Test Report No. F690501/LF-CTSGP06-03316
To:
Date: February 20, 2006
Page 1 of 4
HERAEUS ORIENTAL HITEC CO.,LTD
587-122
Hankik-dong
Nam-gu
INCHEON 402-040
Korea
The following merchandise was submitted and identified by the client as :
Commodity
: Au wire(HA6)/HP
SGS File No.
: GP06-03316
Received Date
: February 13, 2006
Test Performing Date
: February 14, 2006
Test Performed
: SGS Testing Korea tested the sample(s) selected by applicant with following results
Test Results
: For further details, please refer to following page(s)
Buyer(s)
: SONY
SGS Testing Korea Co. Ltd.
Brendan Lee
Patrick An
Monet Jeong
Jinee Song
/Testing Person
Jeff Jang / Technical Mgr
Jason Han / Lab Director
This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and
jurisdictional issues defined therein. The results shown in this test report refer only to the sample (s) tested unless otherwise stated. This Test Report cannot be reproduced, except
in full, without prior written permission of the Company.
Test Report No. F690501/LF-CTSGP06-03316
Sample No.
: GP06-03316.001
Sample Description
: Au wire(HA6)/HP
Style/Item No.
: N/A
Comments
: Material is Au.
Date: February 20, 2006
Page 2 of 4
Heavy Metals
Test Items
Unit
Test Method
MDL
Results
Cadmium(Cd)
mg/kg
US EPA 3050B(1996), US EPA 6010B(1996)
0.5
N.D.
Lead (Pb)
mg/kg
US EPA 3050B(1996), US EPA 6010B(1996)
5
N.D.
Mercury (Hg)
mg/kg
US EPA 3052(1996), US EPA 6010B(1996)
2
N.D.
Hexavalent Chromium (Cr VI)
mg/kg
US EPA 3060A(1996), US EPA 7196A(1992)
1
N.D.
Flame Retardants-PBBs/PBDEs
Test Items
Unit
Test Method
MDL
Results
Monobromobiphenyl
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Dibromobiphenyl
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Tribromobiphenyl
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Tetrabromobiphenyl
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Heptabromobiphenyl
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Hexabromobiphenyl
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Pentabromobiphenyl
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Octabromobiphenyl
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Nonabromobiphenyl
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Decabromobiphenyl
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Monobromodiphenyl ether
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Dibromodiphenyl ether
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Tribromodiphenyl ether
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Tetrabromodiphenyl ether
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Heptabromodiphenyl ether
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Hexabromodiphenyl ether
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Pentabromodiphenyl ether
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Octabromodiphenyl ether
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Nonabromodiphenyl ether
mg/kg
US EPA 3540C, GC/MS
5
N.D.
Decabromodiphenyl ether
mg/kg
US EPA 3540C, GC/MS
5
N.D.
NOTE:
(1) N.D. = Not detected.(<MDL)
(2) ppm = mg/kg
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) ** = Qualitative analysis (No Unit)
(6) Negative = Undetectable / Positive = Detectable
This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and
jurisdictional issues defined therein. The results shown in this test report refer only to the sample (s) tested unless otherwise stated. This Test Report cannot be reproduced, except
in full, without prior written permission of the Company.
Test Report No. F690501/LF-CTSGP06-03316
Date: February 20, 2006
Page 3 of 4
Picture of Sample as Received:
NOTE:
(1) N.D. = Not detected.(<MDL)
(2) ppm = mg/kg
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) ** = Qualitative analysis (No Unit)
(6) Negative = Undetectable / Positive = Detectable
This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and
jurisdictional issues defined therein. The results shown in this test report refer only to the sample (s) tested unless otherwise stated. This Test Report cannot be reproduced, except
in full, without prior written permission of the Company.
Test Report No. F690501/LF-CTSGP06-03316
Date: February 20, 2006
Page 4 of 4
Flow Chart of Digestion
(EPA 3050B for Cd, Pb)
Cutting/Preparation
Sample Measurement (0.5g)
Add HNO3
Add H2O2
Add HCl
Total Digestion
ICP-AES
DATA
The samples were dissolved totally by pre-conditioning method according to above flow chart.
Operator
Lauren Kim
Section Chief
Jeff Jang
*** End ***
NOTE:
(1) N.D. = Not detected.(<MDL)
(2) ppm = mg/kg
(3) MDL = Method Detection Limit
(4) - = No regulation
(5) ** = Qualitative analysis (No Unit)
(6) Negative = Undetectable / Positive = Detectable
This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification and
jurisdictional issues defined therein. The results shown in this test report refer only to the sample (s) tested unless otherwise stated. This Test Report cannot be reproduced, except
in full, without prior written permission of the Company.
ALS TECHNICHEM (S) PTE LTD
14 Little Road, #07-01 & #08-01, Tropical Industrial Building
Singapore 536987
Phone: (65) 6283 9268 Fax: (65) 6283 9689
Website: www.als.com.au
ALS TECHNICHEM
REPORT
OUR REF NO :
DATE :
ATS/GENV/0575/06/lc
03 April, 2006
COMPANY :
Sumitomo Bakelite Singapore Pte Ltd
1 Senoko South Road
Singapore 758069
DATE SAMPLE RECEIVED :
DATE ANALYSED :
DATE COMPLETED :
28 March, 2006
28 March, 2006
03 April, 2006
SAMPLE DESCRIPTION :
One sample was received with references :Description
TEST REQUESTED :
1.
2.
3.
4.
5.
6.
TEST METHOD :
1.
2.
3.
4.
5.
6.
:
Page 1 of 3
EME-6300 Type H
To determine the Cadmium Content in submitted sample in
accordance with EEC Directive 2002/95/EC.
To determine the Lead Content in submitted sample in
accordance with EEC Directive 2002/95/EC.
To determine the Mercury Content in submitted sample in
accordance with EEC Directive 2002/95/EC.
To determine the Hexavalent Chromium Content in submitted
sample in accordance with EEC Directive 2002/95/EC.
To determine the PBB in submitted sample in accordance with EEC
Directive 2002/95/EC.
To determine the PBDE in submitted sample in accordance with EEC
Directive 2002/95/EC.
The sample was pre-conditioned with reference to EPA3050B with
completely digestion. The analysis was performed by ICP-AES with
reference to EPA6010.
The sample was pre-conditioned with reference to EPA3050B with
completely digestion. The analysis was performed by ICP-AES with
reference to EPA6010.
The sample was pre-conditioned with reference to EPA3052B
with completely digestion. The analysis was performed by
Mercury Analyzer.
The sample was pre-conditioned with reference to EPA3060A.
The analysis was performed by UV-VIS with reference to EPA7196A.
The sample was pre-conditioned with reference to EPA 1614.
The analysis was preformed by GCMS with reference to EPA1614.
The sample was pre-conditioned with reference to EPA 1614.
The analysis was preformed by GCMS with reference to EPA1614.
… 2/-
This Report shall not be reproducted except in full without prior approval of the Management
 This Report may not be used for advertising purposes
ALS TECHNICHEM (S) PTE LTD
14 Little Road, #07-01 & #08-01, Tropical Industrial Building
Singapore 536987
Phone: (65) 6283 9268 Fax: (65) 6283 9689
Website: www.als.com.au
ALS TECHNICHEM
OUR REF NO :
DATE :
COMPANY :
(Continued)
Description
RESULTS :
ATS/GENV/0575/06/lc
03 April, 2006
Sumitomo Bakelite Singapore Pte Ltd
:
Page 2 of 3
EME-6300 Type H
On analysis and calculation from the components, the following results were obtained :-
TESTS
RESULTS
Cadmium (Cd), ppm wt
Not Detected
Lead (Pb), ppm wt
3.1
Mercury (Hg), ppm wt
Not Detected
Hexavalent Chromium (Cr6+), ppm wt
Not Detected
Polybrominated biphenyls (PBB), ppm wt
Not Detected
Polybrominated diphenyl ethers (PBDE), ppm wt
Not Detected
Note :
1) ppm wt : mg/kg
2) Detection Limit :
a)
b)
c)
d)
e)
f)
Cadmium
Lead
Mercury
Hexavalent Chromium
Polybrominated biphenyls
Polybrominated diphenyl ethers
: 2.0 ppm
: 2.0 ppm
: 2.0 ppm
: 2.0 ppm
: 5.0 ppm
: 5.0 ppm
3) Above tests were carried out by ALS chemists: Sin Min Hong, and Geok Cheng Lee
ALS TECHNICHEM (S) PTE LTD
YAO KAIWEN
B.SC., M.SC.
This Report shall not be reproducted except in full without prior approval of the Management
 This Report may not be used for advertising purposes
ALS TECHNICHEM (S) PTE LTD
14 Little Road, #07-01 & #08-01, Tropical Industrial Building
Singapore 536987
Phone: (65) 6283 9268 Fax: (65) 6283 9689
Website: www.als.com.au
ALS TECHNICHEM
OUR REF NO :
DATE :
COMPANY :
(Continued)
Description
ATS/GENV/0575/06/lc
03 April, 2006
Sumitomo Bakelite Singapore Pte Ltd
:
Page 3 of 3
EME-6300 Type H
Measurement Flowchart
Small size or powder by
grinding, milling or cutting
Sample
For Cd/Pb/Hg tests
Acid digestion with
methods: EN1122 or
EPA3050B or EPA3052
or EN13346
Homogenized test
specimens
For Cr(VI) test
Totally dissolved
Extraction with
method
EPA3060A
Solution
Residue appeared
Residue
Solution
Residue is treated with
other acids such as
HF, HBF4, HClO4 or
other methods such as
alkali dissolution, and
residue to be dissolved
into solution
Color
development and
UV-Vis
measurement
Combine two
solutions
ICP for Cd/Pb measurement and Mercury analyzer for Hg measurement
This Report shall not be reproducted except in full without prior approval of the Management
 This Report may not be used for advertising purposes