Liebert Process Fluid Chiller Designed for Marconi Medical Eclipse, Polaris, PD100/150, PD200, Apollo; Medical Match-Up; 60Hz (R 7/00) (SL-16552)

Keeping Business in Business
•
•
•
•
•
•
•
•
Process Fluid Chiller Designed for Marconi Medical
Eclipse, Polaris, PD100/150, PD200, Apollo
Dedicated, equipment-matched cooling supplies the proper temperature and water flow year round.
Factory-tested, piped, wired and charged for hassle-free startup and operation.
Clean, non-ferrous cooling loop, required for sensitive medical equipment.
Local service and parts for quick and knowledgeable maintenance and service.
Optional switch-over to alternate water source provides redundant, continuous operation.
Optional remote monitoring systems keep you informed of chiller operation.
UL/CSA certified.
ISO 9001 certified company.
Eclipse/Polaris Specifications
Fluid Specified
Glycol
Max Heat Dissipation—BTUH (kW)
75,000 (22)
Fluid Temperature Range—°F (°C)
50-55 (10-13)
Fluid Flow Rate—GPM (l/m)
15.0 (57.0)
Fluid Pressure Drop—PSI (kPa)
65.0 (448.0)
Process Fluid Chiller Specifications
Model Number
PS096A
PS096A
PS096A
Fluid Circulated
Water
Ethylene Glycol
Propylene Glycol
Net Cooling Capacity—BTUH (kW)
83,400 (24.4)
79,000 (23.1)
75,600 (22.2)
Leaving Fluid Temperature—°F (°C)
50 (10)
50 (10)
50 (10)
Fluid Flow Rate—GPM (l/m)
15 (57)
15 (57)
15 (57)
Eclipse/Polaris Pressure Drop—PSI (kPa)
65 (448)
65 (448)
65 (448)
Chiller Pressure Drop—PSI (kPa)
7.6 (52.4)
10.2 (70.3)
12.0 (82.7)
Pump Total Head—PSI (kPa)
86.5 (596.4)
86.5 (596.4)
86.5 (596.4)
Head Available for Piping Circuit—PSI (kPa)
13.9 (95.8)
11.3 (77.9)
9.5 (65.5)
2 (1.5)
2 (1.5)
2 (1.5)
Pump HP (kW)
Process Fluid Chiller Designed for Marconi Medical Eclipse, Polaris, PD100/150, PD200, Apollo
1
D
B
A
C
Model No.
A - Width
Inches (mm)
B - Height
Inches (mm)
C - Depth
Inches (mm)
D
Weight
Lbs. (kg)
Voltage
(60 Hz)
PS096A
77 (1956)
40 (1016)
38.5 (978)
5.5 (140)
750 (340)
460, 3-phase; 208/230, 3-phase
PS096A
77 (1956)
40 (1016)
38.5 (978)
5.5 (140)
750 (340)
460, 3-phase; 208/230, 3-phase
Standard Features
Accessories
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Indoor/outdoor cabinet
Hermetic compressor
Refrigerant dehydrator
Expansion valve
Refrigerant receiver
Stainless steel fluid reservoir expansion tank
Pressure relief valve
Hot gas bypass valve capacity control
Stainless steel pump
Optional Features
• Refrigerant gauges and reservoir heater
Emergency water bypass
Enviro-source emergency bypass
Water level control and alarm system
Fluid pressure gauge
Check valve
Dial thermometer
Relief valve
Circuit Setter
Required Options
• Multistage, high-head pump
• Part #154650G1—Wallbox with flow meter, filter,
thermometers, flow switch and ball valves
Note: Contact Liebert Application Engineering for gradient upgrades or Medical Marconi systems without heat
exchangers.
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
Phone: 800.877.9222
Fax: 614.841.6022
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco
Italy
Phone: 39.049.9719.111
Fax: 39.049.5841257
Liebert Web Site—http://www.liebert.com
23/F Allied Kajima Bldg.
138 Gloucester Road
Wanchai
Hong Kong
Phone: 852.2.572.2201
Fax: 852.2.572.1182
©2000 Liebert Corporation. All rights
reserved throughout the world.
Specifications subject to change without
notice.
®Liebert and the Liebert logo are
registered trademarks of Liebert
Corporation. All names referred to are
trademarks or regisered trademarks of
their respective owners.
SL-16552 (07/00)