Derating Download

For Instructions, please see:
http://www.erni.com/DB/derating/DERATING-Instructions.pdf
DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b)
Current (A]
M12 connector with 4 contacts Male
max component temperature 85°C
12
10
8
6
4
Base curve [A]
Derating curve [A]
2
Temperature [°C]
0
0
20
30
40
50
60
70
80
Base curve [A]
8,5
7,8
7
6,15
5,2
4
2,2
Derating curve [A]
6,80
6,24
5,60
4,92
4,16
3,20
1,76
© ERNI Electronics GmbH 2008
10
90
100
110
120
130
All rights reserved. Only for information. Subject to modification without prior notice.
For Instructions, please see:
http://www.erni.com/DB/derating/DERATING-Instructions.pdf
DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b)
Current (A]
M12 connector with 4 contacts Male
max component temperature 105°C
12
10
8
6
4
Base curve [A]
Derating curve [A]
2
Temperature [°C]
0
0
20
30
40
50
60
70
80
90
100
Base curve [A]
9,75
9,15
8,5
7,8
7
6,15
5,2
4
2,2
Derating curve [A]
7,80
7,32
6,80
6,24
5,60
4,92
4,16
3,20
1,76
© ERNI Electronics GmbH 2008
10
110
120
130
All rights reserved. Only for information. Subject to modification without prior notice.
For Instructions, please see:
http://www.erni.com/DB/derating/DERATING-Instructions.pdf
DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b)
Current (A]
M12 connector with 4 contacts Male
max component temperature 125°C
12
10
8
6
4
Base curve [A]
Derating curve [A]
2
Temperature [°C]
0
0
10
20
30
40
50
60
70
80
90
100
110
120
Base curve [A]
10,85 10,3
9,75
9,15
8,5
7,8
7
6,15
5,2
4
2,2
Derating curve [A]
8,68
7,80
7,32
6,80
6,24
5,60
4,92
4,16
3,20
1,76
© ERNI Electronics GmbH 2008
8,24
130
All rights reserved. Only for information. Subject to modification without prior notice.
Similar pages