POWERBOX MI-PC6Z-IZ

MEDICAL & MILITARY
MI COMPAC Series
5 0 - 3 0 0 W AT T S M I L I TA R Y R E A D Y T O U S E C O M P O N E N T
Features
•
•
•
•
•
•
•
Inputs 28Vdc and 270Vdc
Outputs 1 to 3, 1 to 95Vdc
EMI Compliance: MIL-STD-461C&D/E
Transients & Spikes: MIL-STD-704A, 1275A/B
Quality System MIL-1-45208
Reverse polarity protected
Low noise FM control
Specifications
ENVIRONMENTAL
INPUT
Storage temperature
Nominal input
28Vdc
270Vdc
Input range
18 – 50Vdc
125V – 400Vdc
Input spike limit
MIL-STD-704A
MIL-STD-1275A/B
-600V to +600Vdc
-250V to +250Vdc
800Vdc max
-600V to +600Vdc
Input surge limit
100Vdc
500Vdc
Overvoltage shutdown
50Vdc
400Vdc
Inrush current
110%
110% of input typical
Reverse polarity protection
Recommended Fuse
10A
2A FO3A type
Operating temperature case
Shutdown temperature
270Vdc
Output power
250W
250W
Clamp voltage
60Vdc
420Vdc
Overload protection
20A
4A
Set point accuracy
0.5% V nom typical
Load/Line regulation
0.2-0.5% V nom typical
Output temperature drift
0.01%/°C
Output noise
1%pp V nom
Output voltage trimming
50%-110%
Remote sense compensation
Current Limit
INPUT POWER LEADS
Conduct emissions
CE01, CE03, CE07, CE101, CE102
MIL-STD-461C & D (1 Up)
CE101 MIL-STD-461E (2 Up & 3Up)
Conducted susceptibility
CS01, CS02, CS06, CS101, CS114, CS116
MIL-STD-461C & D (1 Up)
CS101, CS114, CS116 MIL-STD-461E (2 Up & 3Up)
Output to case
50–100W
200W
300W
100–200W
250–300W
MI-RC [a] [b] [b] [b] – [c] [d] [d] [d]
150–300W
A=INPUT VOLTAGE
105% – 125%
18-50V
Z = 2Vdc
2 = 15Vdc
6=270Vdc
125-475V(1)
Y = 3.3Vdc
3 = 24Vdc
28Vdc input: 2,121Vrms
270Vdc input: 2,500Vrms
500Vrms
O = 5Vdc
L = 28Vdc
M = 10Vdc
4 = 48Vdc
C=PRODUCT
GRADE
I = -40°C to +85°C
M = -55°C to +85°C
1 = 12Vdc
D=OUTPUT
POWER/CURRENT
4,242Vrms
B=OUTPUT
VOLTAGE
2=28Vdc
219x64x25mm
219x125x25mm
219x186x25mm
Isolation characteristics
Input to case
Dual output
MI-LC [a] [b] – [c] [d]
MI-MC [a] [b] – [c] [e]
MI-NC [a] [b] – [c] [f]
MI-PC [a] [b] [b] – [c] [d] [d]
MI-QC [a] [b] [b] – [c] [e] [d]
NOMINAL RANGE
OPERATING
Input – output
Selection Table
Single output
# For conduction cooled models add – cc at end of model number
Please substitute selection character (e.g. [a]) with value designator in the
appropriate table below.
0.5V
MI-LC
MI-MC, MI-PC
MI-NC, MI-QC, MIRC
+95°C typical
EMI/RFI characteristics (MIL-STD-461C, D &E)
Triple output
MECHANICAL
Dimensions
+85°C
STANDARDS AND APPROVALS
OUTPUT
28Vdc
+100°C
E=OUTPUT
POW./CUR.
5V
<5V
肁5V
F=OUTPUT
POW./CUR.
<5V
肁5V
<5V
Y = 50W
10A
U = 200W
–
S = 300W
–
X = 75W
15A
S= –
60A
P= –
90A
W= 100W
20A
V= –
30A
(1) These units rated at 75% load from 125-150Vin: 5Vout @ 100W; 2Vout and
3.3Vout @ 30A.
382
5 0 - 3 0 0 W AT T S M I L I TA R Y R E A D Y T O U S E C O M P O N E N T
Technical Illustrations
Your dependable power partner – www.powerbox.com.au
MEDICAL & MILITARY
MI COMPAC Series
383