VICOR VI

12 1-800-735-6200
Rev 3 1 of 2
VI-J00
MiniMod
DC-DC Converters
25 to 100 Watts
Converter Selection Chart
VI-J
Features
■
■
■
■
■
■
■
■
■
■
Output Voltage
Input Voltage
Up to 50W/Cubic Inch
UL, CSA, TÜV, VDE, BABT
CE Marked
Up to 90% Efficiency
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
Remote Sense and Current Limit
Logic Disable
Wide Range Output Adjust
ZCS Power Architecture
Low Noise FM Control
Nominal
0 =
1 =
W=
2 =
3 =
N =
4 =
T =
5 =
6 =
7 =
The VI-J00 MiniMod family establishes
a new standard in component-level
DC-DC converters. This “junior” size
complement to the higher power VI-200
family offers up to 100W of isolated and
regulated power in a board mounted
package. At one-half the size and twice
the power density of previous 100W
modules, and with a maximum operating
temperature rating of 100˚C, the MiniMod
opens new horizons for board-mounted
(distributed) power architectures.
Utilizing Vicor’s “zero-currentswitching” forward converter technology,
proven by an installed base of over
8 million units, the MiniMod family
combines state of the art power density
with the efficiency, low noise and
reliability required by next generation
power systems.
Range
12V
10 - 20V(5) n/a
24V
21 - 32V(2) 18V
24V
18 - 36V(2) n/a
36V
21 - 56V(6) 18V
48V
42 - 60V(3) 36V
48V
36 - 76V(2) n/a
72V
55 - 100V(2) 45V
110V
66 - 160V(2) n/a
150V
100 - 200V(2) 85V
300V
200 - 400V(3) 170V
150/300V 100 - 375V(6) 90V
Product Grade/
Operating Temp.
Product Highlights
E =
C =
I =
M=
-10°C
-25°C
-40°C
-55°C
to
to
to
to
+100°C
+100°C
+100°C
+100°C
Z =
2V
Y = 3.3V
0 =
5V
X = 5.2V
W = 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
22V
36V
n/a
60V
72V
n/a
110V
n/a
215V
425V
n/a
Product Grade/
Storage Temp.
E
C
I
M
=
=
=
=
-20°C
-40°C
-55°C
-65°C
2
N
3
L
J
K
4
H
F
D
B
= 15V
= 18.5V
= 24V
= 28V
= 36V
= 40V
= 48V
= 52V
= 72V
= 85V
= 95V
Output Power/Current
VOUT ≥ 5V
Z
=
25W
Y
=
50W
X
=
75W
W
= 100W
to +105°C
to +105°C
to +105°C
to +105°C
Max. Output For 5V Outputs > 5V Outputs < 5V Outputs
(1)
50W
50W
10A
(2)
75W
100W
20A
(3)
100W
100W
20A
Z
Y
X
W
VOUT < 5V
=
5A
=
10A
=
15A
=
20A
Max. Output For 5V Outputs > 5V Outputs < 5V Outputs
(4)
75W
75W
15A
(5)
50W
75W
15A
(6)
50W
75W
10A
*Brownout 75% of rated load; transient voltage for 1 second.
Mechanical Drawing
.49
(12,4)
.30±.015
(7,6)±(0,38)
2.28
(57,9)
1.30
(33,0)
.080 Dia (2) places
Solder plate
over copper alloy
.65
(16,5)
Pin #
1
4
9
3
8
VI-J00
2.10
(53,4)
2
Packaging Options
SlimMods™, high power density,
flangeless packages and FinMods™,
featuring integral finned heatsinks.
Brownout /
Transient*
1
.15
(3,8)
SlimMod: Option suffix: - S
Example: VI - JXX - XX - S
FinMod: Option suffix: - F1 and - F2
Examples:
VI - JXX - XX -F1, 0.75" height
VI - JXX - XX -F2, 1.00" height
7
6
5
1.40
1.00 (35,6)
.70 (25,4)
.40 (17,8)
(10,2)
.35± .015
(8,9)±(0,38)
FULL R
Function
+In
2
Gate In
3
Gate Out
4
-In
5
+Out
6
+Sense
7
Trim
8
–Sense
9
–Out
.040 (1,0) Dia (7) places
Solder plate
over copper alloy
.15
(3,8)
2.40
(61,0)
Product ID
this surface
1.90
(48,3)
.30
(7,6) Min.
.22
(5,6) Min.
.50
(12,7)
1.75
(44,4) Max.
+.030 (0,76)
-.000 (0)
.01
.12
(3,0)
Aluminum Base
For the latest Vicor Product Information: www.vicorpower.com
12 1-800-735-6200
Rev 3 2 of 2
Converter Specifications
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
VI-J00 E-Grade
PARAMETER
MIN.
■ Input Characteristics
Inrush charge
Input reflected ripple current – pp
Input ripple rejection
25+20Log
■ Output Characteristics
Setpoint accuracy
Load/line regulation
Load/line regulation
■ Control Pin Characteristics
Gate out impedance
Gate in impedance
Gate in high threshold
Gate in low threshold
Gate in low current
■ Dielectric Withstand Characteristics
Input to output
Output to baseplate
Input to baseplate
MAX.
VI-J00 C-, I-, M-Grade
MIN.
60x10 -6
10%
No load power dissipation
Output temperature drift
Long term drift
Output ripple - pp:
2V, 3.3V
5V
10-48V
Trim range1
Total remote sense compensation
Current limit
Short circuit current
TYP.
( )
TYP.
MAX.
UNITS
TEST CONDITIONS
60x10 -6
10%
100x10-6
Coulombs
IIN
Nominal line
Nominal line, full load
dB
120 Hz, nominal line
dB
2400 Hz, nominal line
( )
( )
Vin
Vout
30+20Log Vin
Vout
20+20Log Vin
Vout
1.35
2
1.35
2
Watts
1.0%
2.0%
0.5%
1.0%
0.5%
0.05%
0.2%
1.0%
0.2%
0.5%
VNOM
VNOM
VNOM
0.02
0.02
0.01
0.02
0.02
%/°C
%/1K hours
200
5%
3%
100
2%
0.75%
150
3%
1.5%
110%
mV
50%
0.5
105%
105%
110%
135%
140%
50%
0.5
105%
105%
50
10 3
6
125%
130%
50
10 3
6
0.65
0.65
6
3,000
500
1,500
6
3,000
500
1,500
Over rated temperature
20 MHz bandwidth
20 MHz bandwidth
20 MHz bandwidth
VNOM
Volts
INOM
INOM
0.25V max. neg. leg
Automatic restart
Ohms
Ohms
Volts
Volts
mA
Use open collector
VRMS
VRMS
VRMS
■ Thermal Characteristics
Efficiency
Baseplate to sink
78-88%
0.4
80-90%
0.4
°C/Watt
■ Mechanical Specifications
Weight
3.0 (85)
3.0 (85)
Ounces (Grams)
110V,
LL to HL, 10% to Full Load
LL to HL, No Load to 10%
Baseplate earthed
With Vicor P/N 04308
12V and 15V outputs, standard trim range ±10%. Consult factory for wider trim range.
For product compliance with agency standards please refer to pages 67 - 69.
For the latest Vicor Product Information: www.vicorpower.com
73