P-DUKE FEC40-48S3P3W 40 watts dc-dc converter Datasheet

FEC40W SERIES
40 WATTS
DC-DC CONVERTER
FEATURES
• 40 WATTS MAXIMUM OUTPUT POWER
• OUTPUT CURRENT UP TO 10A
• STANDARD 2.00 X 2.00 X 0.40 INCH PACKAGE
• HIGH EFFICIENCY UP TO 89%
• 4:1 ULTRA WIDE INPUT VOLTAGE RANGE
• SIX-SIDED CONTINUOUS SHIELD
• FIXED SWITCHING FREQUENCY
• UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
OPTIONS
Negative logic Remote On/Off
APPLICATIONS
Wireless Network
Telecom/Datacom
Industry Control System
Measurement Equipment
Semiconductor Equipment
DESCRIPTION
The FEC40W series offer 40 watts of output power from a 2.00 x 2.00 x 0.40
inch package. The FEC40W series with 4:1 ultra wide input voltage of
9~36VDC and 18~75VDC and features 2000VDC of isolation, short-circuit
and over-voltage protection.
T E C H N I C A L S P E C I F I C AT I O N
All specifications are typical at nominal input, full load and 25ºC otherwise noted
INPUT SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage accuracy
± 1%
Minimum load (Note 6)
See Table
Voltage adjustability (Note 7) Single and Dual output
Line regulation
LL to HL at Full Load
± 10%
Single/Dual
± 0.2%
Load regulation
Single
Min. Load to Full Load
(Note 8)
Dual
Load cross regulation (Note 9)
Dual
Ripple and noise
± 0.5%
± 1%
± 5%
20MHz bandwidth
See table
±0.02% / ºC, max.
Temperature coefficient
Transient response recovery time
25% load step change
3.3VDC output
5VDC output
Over voltage protection 12VDC output
Zener diode clamp
15VDC output
±12VDC output
±15VDC output
Over load protection
% of FL at nominal input
250µs
3.9VDC
6.2VDC
15VDC
18VDC
±15VDC
±18VDC
150%, max.
Efficiency
Input to Output
Input(Output) to Case
Case grounding
500VDC
Isolation capacitance
Switching frequency
Safety approvals
-40ºC ~ +50ºC (without derating)
+50ºC ~ +105ºC (with derating)
+105ºC
9
Storage temperature range
Over temperature protection
Thermal impedance
(Note 11)
Thermal shock
Dimensions
Weight
MIL-HDBK-217F
+110ºC
9.2ºC/Watt
7.6ºC/Watt
MIL-STD-810F
Without Heat-sink
With Heat-sink
MIL-STD-810F
5% to 95% RH
EMC CHARACTERISTICS
EMI (Note 12)
FR4 PCB ESD
Potting material
-55ºC ~ +125ºC
10 ohms, min.
Vibration
2500pF, max.
Relative humidity
300kHz±10%
Nickel-coated copper
Base material
Page 1 of 3
See table
1600VDC, min. 1minute
1600VDC, min. 1minute
Connect case to –INPUT
with decoupling Y Cap
IEC60950-1, UL60950-1, & EN60950-1
Case material
MTBF (Note 1)
ENVIRONMENTAL SPECIFICATIONS
Maximum case temperature
GENERAL SPECIFICATIONS
Isolation resistance
9 ~ 36VDC
18 ~ 75VDC
Input filter
Pi type
24VDC input
50VDC 100ms, max.
Input surge voltage
48VDC input
100VDC 100ms, max.
Input reflected ripple current
20mAp-p
Nominal Vin and
Power up
20ms, max.
Start up time
constant resistive load Remote ON/OFF
20ms, max.
24VDC input
9VDC
Start-up voltage
48VDC input
18VDC
24VDC input
8VDC
Shutdown voltage
16VDC
48VDC input
Remote ON/OFF (Note 10)
Positive logic (standard)
DC-DC ON
Open or 3V < Vr < 12V
DC-DC OFF
Short or 0V < Vr < 1.2V
Negative logic (option)
DC-DC ON
Short or 0V < Vr < 1.2V
DC-DC OFF
Open or 3V < Vr < 12V
Input current of remote control pin Nominal input
-0.5mA ~ +0.5mA
24VDC input
10mA
Remote off state input current
48VDC input
5mA
Continuous, automatics recovery Operating ambient temperature
Short circuit protection
Isolation voltage
24VDC nominal input
48VDC nominal input
40 Watts, max. Input voltage range
Output power
Epoxy (UL94 V-0) Radiated immunity
2.00 X 2.00 X 0.40 Inch Fast transient (Note 13)
(50.8 X 50.8 X 10.2 mm)
Surge (Note 13)
60g (2.11oz)
Conducted immunity
5
6.617 x 10 hrs
www.pduke.com
EN55022
Class A, Class B
EN61000-4-2
Air ± 8kV
Contact ± 6kV
Perf. Criteria A
EN61000-4-3
10 V/m
Perf. Criteria A
EN61000-4-4
± 2kV Perf. Criteria B
EN61000-4-5
± 1kV
Perf. Criteria A
EN61000-4-6
10 Vr.m.s
Perf. Criteria A
2014/4/21
FEC40W SERIES
40 WATTS
Model
Number
Input
Range
Output
Voltage
Output Current
Min. load
FEC40-24S3P3W
FEC40-24S05W
FEC40-24S12W
FEC40-24S15W
FEC40-24D12W
FEC40-24D15W
FEC40-48S3P3W
FEC40-48S05W
FEC40-48S12W
FEC40-48S15W
FEC40-48D12W
FEC40-48D15W
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
± 12 VDC
± 15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
± 12 VDC
± 15 VDC
0mA
0mA
50mA
50mA
±65 mA
±50 mA
0mA
0mA
50mA
50mA
±65 mA
±60 mA
DC-DC CONVERTER
(2)
No load
(3)
(4)
(5)
Full load
Output
Ripple & Noise
Input Current
Eff
(%)
Capacitor
Load max
10000mA
8000mA
3333mA
2666mA
± 1667mA
± 1333mA
10000mA
8000mA
3333mA
2666mA
± 1667mA
± 1333mA
50mVp-p
50mVp-p
75mVp-p
75mVp-p
120mVp-p
150mVp-p
50mVp-p
50mVp-p
75mVp-p
75mVp-p
120mVp-p
150mVp-p
75mA
95mA
50mA
50mA
60mA
70mA
55mA
60mA
30mA
25mA
30mA
30mA
87
88
87
87
86
86
87
89
87
88
86
86
25750µF
13600µF
2360µF
1510µF
± 1200µF
± 750µF
25750µF
13600µF
2360µF
1510µF
± 1200µF
± 750µF
Note
1.
2.
3.
4.
5.
6.
MIL-HDBK-217F @Tc=70 ºC, Full load.
Typical value at nominal input and full load. (20MHz BW.)
Typical value at nominal input and no load.
Typical value at nominal input and full load.
Test by minimum input and constant resistive load.
The output requires minimum loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices,
however they may not meet all listed specification.
7. For the single output: Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +SENSE should be
connected to its corresponding +OUTPUT and likewise the -SENSE should be connected to its corresponding –OUTPUT.
8. Load regulation for dual output : Min load to 100% load balanced on all outputs.
9. Cross regulation for dual output : asymmetrical load 25% / 100% FL
10. The CTRL pin voltage is referenced to –INPUT
To order negative logic ON/OFF control add the suffix-N (Ex: FEC40-24S05W-N).
11. Heat-sink is optional and P/N:7G-0026C-F.
12. The FEC40W series standard module meets EN55022 Class A and Class B with external components.
For more detail information, please contact with P-DUKE.
13. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220µF/100V.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
FEC40-48S05W Derating Curve
FEC40-48S05W Derating Curve With Heat-sink(Note 11)
FEC40-48S05W Efficiency VS Input Voltage
FEC40-48S05W Efficiency VS Output Load
92
95
90
90
85
EFFICIENCY(%)
EFFICIENCY(%)
80
88
86
84
75
70
65
60
55
50
82
45
40
80
18
Page 2 of 3
24
30
36
42
48
54
INPUT VOLTAGE(V)
60
66
72
75
10
www.pduke.com
20
30
40
50
60
% OF FULL LOAD
70
80
90
100
2014/4/21
FEC40W SERIES
40 WATTS
DC-DC CONVERTER
MECHANICAL DRAWING
1. All dimensions in Inch (mm)
Tolerance: X.XX±0.02 (X.X±0.5)
X.XXX±0.01 (X.XX±0.25)
2. Pin pitch tolerance ±0.014(0.35)
3. Pin dimension tolerance ±0.004 (0.1)
EXTERNAL OUTPUT TRIMMING
PIN CONNECTION
PIN
SINGLE
DUAL
1
+INPUT
2
-INPUT
+INPUT
-INPUT
CTRL
+OUTPUT
COM
COM
-OUTPUT
TRIM
3
CTRL
4
-SENSE
+SENSE
+OUTPUT
-OUTPUT
TRIM
5
6
7
8
Page 3 of 3
Output can be externally trimmed by
using the method shown below.
( ) for dual output trim
TRIM UP
TRIM DOWN
4(7)
8(8)
RU
8(8)
www.pduke.com
RD
5(4)
2014/4/21
Similar pages