AIMTEC AMEPR60-24250AZ Up to 5a | ac-dc led driver Datasheet

Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
• AC-DC Constant Current or Constant
Voltage LED Driver
• Input range 90-305VAC/47-440Hz
• High Efficiency up to 89%
• Operating temperature -40 to 85°C
• Dimmable via analog / 0-10V dimming ②
Models
Single output
Model
Output
Voltage
③
Range (V)
AMEPR60-50120AZ
AMEPR60-36170AZ
AMEPR60-24250AZ
Output
Current
③
(A)
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
90-305/47-440
120-430
36-50
0-1.27
24-36
0-1.77
90-305/47-440
120-430
12-24
0-2.55
90-305/47-440
120-430
5-12
0-5.2
90-305/47-440
AMEPR60-12500AZ
120-430
•
•
•
•
•
Over Temperature Protection
Over Current Protection
Waterproof Case rated IP68
Power Factor Correction
Short Circuit Protection
Mode of
Operation
Constant
Current
Constant
Voltage ②
Constant
Current
Constant
Voltage ②
Constant
Current
Constant
Voltage ②
Constant
Current
Constant
Voltage ②
Max
Output
Power
(W) ①
Efficiency
(%)
60
89
63.8
86
59.8
88
63.7
86
60
87
61
85
60
85
62
82
Exceeding the maximum output power will permanently damage the converter
The dimming feature is not supported when units are used in Constant Voltage mode only.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
①
②
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
Power Factor
External fuse
Start up time
Surge voltage
Output Specifications
Parameters
Current accuracy (CC Mode)
Voltage accuracy (CV Mode)
Line regulation
Load regulation
Ripple & Noise ④
www.aimtec.com
F 052.1e R3.R
Conditions
Typical
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
30
50
0.5
0.7
0.73
0.33
250
2sec
Conditions
Typical
±3
±3
±1
±3
75
LL-HL
0-100% load
20MHz Bandwidth
Tel: +1 514 620 2722
1 of 12
Maximum
Units
A
mA
A
0.97
0.93
250V/1.5A
440
ms
V
Maximum
Units
%
%
%
%
mV p-p
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Output Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Conditions
Typical
Rated
Units
Hold-up time
90
Current adjustment range
100-0
Minimum Load Voltage
See the models table
④ Tested with 0.1µF (C/C) or (M/C) and 47µF (E/C) parallel capacitors at the end.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Isolation Capacitance
3 sec/3.5mA
500VDC
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Over temperature protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting
Wires
Weight
Dimensions (L X H X W)
MTBF
>1000
1000
Conditions
ms
%
3000
VAC
MΩ
pF
Typical
Maximum
130
95-110% of Iout
110% of Vout
Continuous
Auto recovery
>105°C
-40 to +85
With derating over 55°C
Units
KHz
o
100
-40 to +95
±0.02
Free air convection
Plastic
Epoxy (IP67 rated)
UL1015 18AWG *20CM
350
5.30 x 2.27 x 1.59 inches
134.80 x 57.68 x 40.50 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
95
C
C
o
C
% / oC
o
% RH
g
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 052.1e R3.R
cULus, CE
UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13
Information Technology Equipment
EN55022 Class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2
RF, Electromagnetic Field Immunity
IEC 61000-4-3
Electrical Fast Transient / Burst Immunity
IEC 61000-4-4
Surge Immunity
IEC 61000-4-5
RF, Conducted Disturbance Immunity
IEC 61000-4-6
Power frequency Magnetic Field Immunity
IEC 61000-4-8
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Dimensions
End View
40.50
(1.59)
Top View
16.75
(0.66)
137.33
(5.41)
60.00
(2.36)
32.00 60.00
(1.26) (2.36)
Side View
200.00
(8.00)
200.00
(8.00)
40.50
(1.59)
Input/Output Wires are 18 AWG 20cm
2.30
(0.09)
161.30
(6.35)
Analog (resistive) Dimming Application Circuit
AC
BROWN
L
GREEN
+Vout
AMEPR60-AZ
BLUE
N
F 052.1e R3.R
1
1st LED
-Vout
1
BLUE
WHITE
www.aimtec.com
Model Number
RED
AMEPR60-50120AZ
AMEPR60-36170AZ
AMEPR60-24250AZ
AMEPR60-12500AZ
Maximum Pot
Value (kΩ)
26.00
16.95
26.10
34.10
BLACK
Pot
Tel: +1 514 620 2722
3 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
0-10V Dimming Application Circuit
U1
+Vs
(Blue)
0-10Vdc
Pin 1
-Vs
(White)
Pin 2
R28
1K5, 0805
LTV-817C
GND
Temperature Graph
Free Air Convection
55 º C
Output Power %
100
80
Safe Operating Area
60
40
20
0
-40
-20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
4 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Efficiency Vs. Input Voltage & Output Current (Constant Current Mode)
AMEPR60-50120AZ
AMEPR60-36170AZ
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
5 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Efficiency Vs. Input Voltage & Output Current (Constant Current Mode)
Continued
AMEPR60-24250AZ
AMEPR60-12500AZ
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
6 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
PFC Value vs. Output Load Current (Constant Current Mode)
AMEPR60-50120AZ
AMEPR60-36170AZ
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
7 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
PFC Value vs. Output Load Current (Constant Current Mode)
Continued
AMEPR60-24250AZ
AMEPR60-12500AZ
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
8 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Constant Current vs. Constant Voltage Mode
AMEPR60-50120AZ
AMEPR60-36170AZ
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
9 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Constant Current vs. Constant Voltage Mode
Continued
AMEPR60-24250AZ
AMEPR60-12500AZ
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
10 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Dimming Control (Output Current vs. Radj)
AMEPR60-50120AZ
AMEPR60-36170AZ
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
11 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR60-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Dimming Control (Output Current vs. Radj)
Continued
AMEPR60-24250AZ
AMEPR60-12500AZ
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
12 of 12
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages