POWER
NTS350 Series
350 Watts
Data Sheet
Total Power: 200 - 350 Watts
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Single
SPECIAL FEATURES
ƒƒ Active power factor correction
ƒƒ IEC EN6100-3-2 compliance
ƒƒ Remote sense
ƒƒ Power fail and remote inhibit
ƒƒ Single wire current sharing
ƒƒ Built-in EMI filter
ƒƒ Low output ripple
ƒƒ 5 V standby
ƒƒ 12 V fan output
ƒƒ Overvoltage protection
ƒƒ Overload protection
ƒƒ Thermal overload protection
ƒƒ DC power good
ƒƒ Built in OR-ing diode/FET
ƒƒ Optional fan cover (-CF suffix)
ƒƒ Optional end fan cover (-CEF suffix)
Electrical Specifications
SAFETY
ƒƒ TUV
ƒƒ UL
ƒƒ CSA
ƒƒ cULus
ƒƒ NEMKO
ƒƒ AUSTEL
ƒƒ CB
ƒƒ CE
ƒƒ CCC
60950
0950
60950
60950 (-CEF)
60950
60950
Certificate and report
Mark (LVD)
Certificate
Input
Input ra­nge:
85 - 264 Vac (wide range)
Frequency:
47 - 440 Hz (47- 63 Hz for -CEF versions)
Inrush current:
38 A max., cold start @ 25 °C
Efficiency:
85% typical at full load
EMI filter:
FCC Class B conducted and radiated; CISPR22 Class B conducted
and radiated; EN55022 Class B conducted and radiated;
VDE0878PT3 Class B conducted and radiated.
Safety ground leakage
current:
< 0.5 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power:
200 W for convection; 350 W with 30CFM forced air
Adjustment range:
± 5%
Standby output:
5 V @ 2 A regulated, ± 5%
Fan output:
12 V @ 1 A, -5 %, +7%, 0.5 A for -CF version
Hold-up time:
20 ms @ 350 W load, 115 Vac nominal line at factory voltage setting
Overload protection:
Short circuit protection on all outputs. Case overload protected @
115 - 130% of peak rating
Overvoltage protection:
20 - 35% above nominal output
LPS100-M
NTS350
Series
Series
Data
Data
Sheet
Sheet
Logic Control
Power failure
TTL logic signal goes high 100 - 500 msec after main output. It goes low at least 4 msec before loss of regulation
Remote on/off
Requires an external contact closure to inhibit outputs
DC OK
TTL logic goes high after the output is in regulation. It goes low when there is loss of regulation.
Remote sense
Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Environmental Specifications
Operating temperature:
0° to 50 °C ambient derate each output as 2.5% per degree from 50° to 70 °C.
Storage temperature:
-40 °C to +85 °C
Electromagnetic susceptibility:
Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity:
Operating; non-condensing 10% to 90% RH
Vibration:
Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances. 2 G peak 8 Hz to 500 Hz, operational
MTBF demonstrated:
1M hours at full load and 25 °C ambient conditions
Ordering Information
Maximum Load Maximum Load
Minimum Load with Convection with 30CFM
Cooling
Forced Air
Peak Load1
Regulation2
Ripple
P/P (PARD)3
29.2 A
33 A
± 2%
120 mV
14.6 A
16.5 A
± 2%
240 mV
4.2 A
7.3 A
8.2 A
± 2%
480 mV
3.7 A
6.5 A
7.4 A
± 2%
540 mV
Model Number
Output Voltage
NTS353
12 V
0A
16.6 A
NTS355
24 V
0A
8.3 A
NTS358
48 V
0A
NTS359
54 V
0A
1.
2­.
3­.
4­.
Peak current lasting < 30 seconds with a maximum 10% duty cycle.
At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
CF suffix added to the model number indicates cover with top fan. -CEF suffix added to the model number indicates cover with end mounted
fan cover and AC inlet
5. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated
as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and
System Integrators, including through Distribution Channels. It is not intended for sale to End Users.
LPS100-M
NTS350
Series
Series
Data
Data
Sheet
Sheet
Pin Assignments
Adjustment Potentiometers
Connector
P1
+V1 Output adjust
+5VSB adjust
SK1
SK5
1
5
6
10
PIN 1
Line
P3
PIN 3
Neutral
Mating Connectors
PIN 5
Ground
SK1 AC input
PIN 1
V1 swp
Molex 09-91-0500 (UK)
PIN 2
- Remote Sense
PINS:08-52-0113
PIN 3
+ Remote Sense
SK2,3,4
Molex BB-124-08
PIN 4
5VSB (standby)
SK5 Control signals
Molex 90142-0010
PIN 5
5VSB return
PIN 6
+12V
PIN 7
Common
PIN 8
Inhibit
PIN 9
DC power good (DC OK)
PIN 10 Power Fail (POK)
Molex 09-50-8051 (USA)
PINS: 90119-2110
Or
Amp: 87977-3
PINS: 87309-8
Artesyn Embedded Technologies Connector Kit #70-841-022 includes all of the above
1.Specifications subject to change without
2.All dimensions in inches (mm), tolerance is ± 0.2”.
3.Specifications are at factory settings
4.Mounting maximum insertion depth is 0.12”.
5.Warranty: 2 year
6.Weight: NTS35X 1.65 lbs/750g. NTS35X-CF 2 lbs/909g. NTS35X-CEF 2.25 lbs/1022g.
NTS350 Series Data Sheet
Mechanical Drawing - CEF option
b
a
a
b
AIR FLOW DIRECTION
1.61"
(40.9)
1.255"
(31.9)
0.862"
(21.9)
0.862"
(21.9)
4.0"
(101.6)
9.15"
(232.3)
a b
b
a
5.85"
(148.6)
2.40"
(61)
6.244"
(158.6)
a b
a b
a b
2.9"
(73.6)
4.7"
(119.6)
0.752"
(19.1)
6.437"
(63.5)
a b
5.5"
(139.7)
#6-32 (8 places)
M3 (8 places)
WORLDWIDE OFFICES
Americas
Europe (UK)
Asia (HK)
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc.
All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal.
www.artesyn.com
For more information: www.artesyn.com/power
For support: [email protected]
NTS350 DS 21Mar2016
NTS350 Series Data Sheet
Mechanical Drawing
+ V OR-ing out (Must be used in parallel operation)
(Do not use in parallel operation)
+ V out
Common
531
SK1
-CF option
(SEE NOTE 5)
1.27 (32.26)
1.14 (29.1)
P1
Voltage
ADJ POT
5
10
1
6
P1
P3
-CF option
a b
b
a
.75 (19.1) (3X)
1.5 (38.10)
5.85 (148.7)
6.25 (158.7)
6.4 (2X)
b a
a b
2.5 (63.5) (4X)
b a
4.0 (101.6)
a b
4.7 (119.6)(2X)
5.5 (139.7) (2X)
7.0 (177.8)
#6-32 (8 places)
M3 (8 places)
P1
P3