AIMTEC AMEOR30-5070AZ Up to 2.5a | ac-dc / dc-dc led driver Datasheet

Click on Series name for product info on aimtec.com
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
FEATURES:





Models
Single output
Model
AC-DC Constant current LED Driver
Input range 90-277VAC/47-440Hz
High Efficiency up to 86%
Operating temperature -40 to 80°C
Dimmable via analog / 0-10Vdc / PWM
(C version see table)
Max
Output
Power
(W) *
Output
Voltage
Range (V)
35
30.72
36
33.6
30
36-50
36-48
24-36
12-24
5-12
AMEOR30-5070AZ
AMEOR30-4864AZ
AMEOR30-36100AZ
AMEOR30-24140AZ
AMEOR30-12250AZ
Output
Current
(A)
0.7
0.64
1
1.4
2.5





Over Temperature Protection
Open frame
Power Factor Correction
SCP, Over Current Protection
5 Years Limited Warranty
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
Efficiency
(%)
90-277/47-440
90-277/47-440
90-277/47-440
90-277/47-440
90-277/47-440
130-390
130-390
130-390
130-390
130-390
86
86
85
84
83
*Exceeding the maximum output power will permanently damage the converter
All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to
part number when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMEOR30-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms
Leakage current
AC current
Power Factor
External fuse
Start up time
Surge voltage
Conditions
Typical
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
25
40
0.3
0.5
0.33
0.16
Maximum
Units
A
mA
A
0.99
0.97
250V/1A
450
2sec
440
ms
V
Maximum
Units
Output Specifications
Parameters
Current accuracy
Line regulation
Load regulation
Ripple & Noise *
Hold-up time
Current adjustment range
Minimum Load Voltage
Conditions
Typical
LL-HL
0-100% load
20MHz Bandwidth
±3
±1
±3
75
50
100-0
%
%
%
mV p-p
ms
%
See the models table
* Tested with 0.1µF (M/C) or (C/C) and 47µF (E/C) parallel capacitors at the end.
www.aimtec.com
F 052.1e R3.K
Tel: +1 514 620 2722
1 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation Resistance
Typical
3sec
Rated
Units
3000
VAC
MΩ
>1000
General Specifications
Parameters
Conditions
Typical
Switching frequency
Maximum
130
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Over temperature protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Wires
Weight
Dimensions (L X H X W)
MTBF
Units
KHz
AMEOR30-5070AZ
AMEOR30-4864AZ
AMEOR30-36100AZ
AMEOR30-24140AZ
AMEOR30-12250AZ
Refer to Constant Current vs. Constant Voltage Mode curve
Continuous
Auto recovery
>105°C
With derating over 60°C
-40 to +80
0.77
0.68
1.04
1.45
2.55
A
oC
100
oC
oC
% / oC
-40 to +95
±0.02
Free air convection
95
UL1015 18AWG * 20CM
220
5.83 x 1.97 x 1.3 inches
148 x 50 x 33 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
% RH
g
Environment Approval
Test
Shock
Vibration
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30 ms
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1 mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 052.1e R3.K
cULus, CE
UL8750, UL60950-1, EN55022, class B
Information Technology Equipment
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient / Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
EN55022 Class B
IEC/EN 61000-3-2, Class C
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 2
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 2
IEC 61000-4-8 Level 1
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
Top View
Dimensions
148.00
(5.83)
139.00
(5.47)
50.00
(1.97)
41.00
(1.61)
4 Mounting Holes-M3
4.50
(0.18)
4.50
(0.18)
5.00
(0.20)
28.00
(1.10)
200.00
(8.00)
Side View
200.00
(8.00)
Input/Output Wires are 18 AWG 20cm
NOTE: to adjust the output current connect a 20K Ohm pot between blue and white wire
Wire connection:
Connection
Wire
Brown
Blue
Green
Red
Black
Blue (Dimming)
White (Dimming)
AC L
AC N
Ground
+V output
-V Output
+ Vs dimming
-Vs dimming
AMEOR30-AZ Analog (resistive) Dimming Application Circuit
BROWN
L
GREEN
+Vout
RED
1st LED
1
AC
AMEPR30-AZ
BLUE
-Vout
N
1
BLUE
WHITE
www.aimtec.com
F 052.1e R3.K
BLACK
Model Number
AMEPR30-5070AZ
AMEPR30-4864AZ
AMEPR30-36100AZ
AMEPR30-24140AZ
AMEPR30-12250AZ
Maximum Pot
Value (kΩ)
9.00
9.00
9.00
26.00
26.10
Pot
Tel: +1 514 620 2722
3 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
AMEOR30-AZ Analog (0-10V) Dimming Application Circuit
AMEOR30-AZ PWM (1KHz) Dimming Application Circuit
Temperature graph
Free Air Convection
55 º C
100
80
Safe Operating Area
60
40
20
0
-40
-20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 052.1e R3.K
Tel: +1 514 620 2722
4 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
Efficiency Vs. Input Voltage & Output Current (Constant current load)
AMEOR30-5070AZ
AMEOR30-4864AZ
(%)
Efficiency Vs. Input Voltage & Output Current
110Vac,
0.128, 73.8
230Vac,
0.128, 68.2
110Vac
230Vac, 0.64,
86.4
110Vac, 0.64,
230Vac
86.2
(A)
www.aimtec.com
F 052.1e R3.K
Tel: +1 514 620 2722
5 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
Efficiency Vs. Input Voltage & Output Current (Constant current load)
(continued)
AMEOR30-36100AZ
(%)
Efficiency Vs. Input Voltage & Output Current
110Vac, 0.2,
81.4
230Vac, 1,
88.0 1,
110Vac,
87.9
110Vac
230Vac
230Vac, 0.2,
74.6
(A)
AMEOR30-24140AZ
(%)
Efficiency Vs. Input Voltage & Output Current
230Vac, 1.7,
87.5
110Vac
110Vac, 1.7,230Vac
86.6
110Vac, 0.34,
81.6
230Vac, 0.34,
79.4
(A)
www.aimtec.com
F 052.1e R3.K
Tel: +1 514 620 2722
6 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
AMEOR30-12250AZ
PFC Value vs. Output Load Current (constant current mode)
AMEOR30-5070AZ
www.aimtec.com
F 052.1e R3.K
Tel: +1 514 620 2722
7 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
PFC Value vs. Output Load Current (constant current mode)
(continued)
AMEOR30-4864AZ
PFC value Vs. Output Load Current
(value)
115VAC, 50%,
0.98
230VAC, 50%,
0.77
115VAC, 115VAC
100%, 1.00230VAC
230VAC,
100%, 0.94
(load)
AMEOR30-36100AZ
PFC value Vs. Output Load Current
(value)
115VAC, 50%,
0.98
115VAC, 115VAC
100%, 0.99230VAC
230VAC,
100%, 0.96
230VAC, 50%,
0.88
www.aimtec.com
F 052.1e R3.K
(load)
Tel: +1 514 620 2722
8 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
PFC Value vs. Output Load Current (constant current mode)
(continued)
AMEOR30-24140AZ
(value)
PFC value Vs. Output Load Current
115VAC,
115VAC
100%, 1.00
230VAC
115VAC, 50%,
0.98
230VAC,
100%, 0.96
230VAC, 50%,
0.91
(load)
AMEOR30-12250AZ
PFC value Vs. Output Load Current
(value)
115VAC, 50%,
0.98
230VAC, 50%,
0.77
115VAC, 115VAC
100%, 1.00230VAC
230VAC,
100%, 0.94
(load)
www.aimtec.com
F 052.1e R3.K
Tel: +1 514 620 2722
9 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
Constant Current vs. Constant Voltage Mode
AMEOR30-5070AZ
0.80
(A)
Constant Current Vs. Constant Voltage
50
36
Normal
Input
0.70
0.60
0.50
0.40
0.30
0.20
0.10
52
50.4
0.00
36
38
40
42
44
46
48
50
52
54 (V)
AMEOR30-4864AZ
(A)
Constant Current Vs. Constant Voltage
Normal Input,
36, 0.64
Normal Input,
48, 0.64
36
38
40
Normal Input,
Normal Input,
48.4, 0.00 50, 0.00
(V)
www.aimtec.com
F 052.1e R3.K
Tel: +1 514 620 2722
10 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
Constant Current vs. Constant Voltage Mode
(continued)
AMEOR30-36100AZ
(A)
Constant Current Vs. Constant Voltage
Normal Input,
36, 1.02
Normal Input,
24, 1.00
24
26
28
Normal Input,
Normal Input,
36.4, 0.00 38, 0.00
(V)
AMEOR30-24140AZ
Constant Current Vs Constant Voltage
(A)
1.6
12.0
1.4
24.0
115 &
230 Vac
1.2
1.0
0.8
0.6
0.4
0.2
24.7
0.0
12
14
www.aimtec.com
F 052.1e R3.K
16
18
20
22
24
26.0
26
28
(V)
Tel: +1 514 620 2722
11 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
Constant Current vs. Constant Voltage Mode
(continued)
AMEOR30-12250AZ
(A)
Constant Current Vs. Constant Voltage
Normal Input,
12, 2.54
Normal Input,
5, 2.51
5
6
7
Normal Input, Normal Input,
14, 0.00
12.3, 0.00
(V)
Dimming Control (Output Current vs. Radj)
AMEOR30-5070AZ
(A)
120%
Output Current vs. Resistance adjustment
100%
0.79
9.00
1.66
Normal
Input
80%
0.45
0.25
0.15
0.07
0.02
0.01
0.01
0.007
60%
40%
20%
0%
0
www.aimtec.com
F 052.1e R3.K
2
4
6
8
10 K(Ω)
Tel: +1 514 620 2722
12 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
Dimming Control (Output Current vs. Radj)
(continued)
AMEOR30-4864AZ
(A)
Output Current vs. Resistance adjustment
Normal Input,
0.007
9.00 , 100%
0.01
Normal Input,
Normal Input,
1.66 , 90%
0.79 , 80%
Normal Input,
Normal
0.45 ,Input,
70%
Normal
0.25 ,Input,
60%
Normal
0.15 , Input,
50%
Normal
0.07 , Input,
40%
Normal
Input,
0.02 , 30%
Normal
Input,
0.02 , 20%
Normal
Input,
0.01 , 10%
0.007, 0%
K(Ω)
AMEOR30-36100AZ
(A)
Output Current vs. Resistance adjustment
Normal Input,
Normal Input,
1.66 , 90%
0.79 , 80%
Normal Input,
Normal
0.45 ,Input,
70%
Normal
0.25 ,Input,
60%
Normal
0.15 , Input,
50%
Normal
0.07 , Input,
40%
Normal
Input,
0.02 , 30%
Normal
Input,
0.02 , 20%
Normal
Input,
0.01 , 10%
0.007, 0%
www.aimtec.com
F 052.1e R3.K
Normal Input,
0.007
9.00 , 100%
0.01
K(Ω)
Tel: +1 514 620 2722
13 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEOR30-AZ
up to 2.5A | AC-DC / DC-DC LED driver
Dimming Control (Output Current vs. Radj)
(continued)
AMEOR30-24140AZ
(A)
Output Current vs. Resistance adjustment
Normal Input,
0
26.00 , 100%
0.01
Normal Input,
Normal Input,
4.26 , 90%
1.50 , 80%
Normal Input,
Normal
0.88 ,Input,
70%
Normal
0.45 , Input,
60%
Normal
0.25 , Input,
50%
Normal
0.15 , Input,
40%
Normal
0.10 , Input,
30%
Normal
Input,
0.02 , 20%
Normal
Input,
0.01 , 10%
0, 0%
K(Ω)
AMEOR30-12250AZ
(A)
Output Current vs. Resistance adjustment
Normal Input,
Normal Input,
4.29 , 90%
1.84 , 80%
Normal Input,
Normal
0.88 ,Input,
70%
Normal
0.50 , Input,
60%
Normal
0.35 , Input,
50%
Normal
0.11 , Input,
40%
Normal
Input,
0.00 , 30%
Normal
Input,
0.00 , 20%
Normal
Input,
0.00 , 10%
0, 0%
Normal Input,
0
26.10 , 100%
0.00
K(Ω)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
.
www.aimtec.com
F 052.1e R3.K
Tel: +1 514 620 2722
14 of 14
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Similar pages