Omron D6F-PH5050AD3 D6f-ph series differential pressure sensor Datasheet

Innovation
D6F-PH Series
Differential Pressure
Sensor
High Impedance MEMS Mass Flow Technology
Economical
I2C Digital Output
Compact Package
High Accuracy, ±3% Reading
Linearized and Temperature Compensated
Resistant to Bypass Tube Length Variation
0-250 Pa, ±50 Pa, ± 500 Pa
www.components.omron.com
www.components.omron.com
ELECTRONICCOMPONENTS
COMPONENTS
ELECTRONIC
D6F-PH Series DIFFERENTIAL PRESSURE SENSOR
High Impedance MEMS Mass Flow Technology
• Economical
• I2C Digital Output
• Compact Package
• High Accuracy, ±3% Reading
• Linearized and Temperature Compensated
• Resistant to Bypass Tube Length Variation
Ordering Information
Measurement Range
0 to 250 Pa (0 to 1 in. H2O)
-50 to +50 Pa (± 0.2 in. H2O)
-500 to +500 Pa (± 2 in. H2O)
Applicable Fluid
Model
D6F-PH0025AD1
D6F-PH0505AD3
D6F-PH5050AD3
Air
Note: The Sensor can be calibrated for different gas types. Consult Omron.
Characteristics
Model
D6F-PH0025AD1
D6F-PH0505AD3
D6F-PH5050AD3
± 50 Pa
± 500 Pa
Measurement Range (See Note 1)
0 to 250 Pa
Calibration Gas (See Note 2)
Air
Port Type
Barb joint, Maximum outside diameter: 4.9mm
Power Supply
2.3 to 3.6 VDC
Current Consumption
6 mA max. with no load and VCC of 3.3 V, GND=0 VDC, 25°C
Resolution
12 bit
Zero Point Tolerance (See Note 4)
± 0.2 Pa
Span Tolerance (See Note 4)
± 3% R.D.
Temperature Compensation
Yes
Span shift due to Temperature Variation
± 0.5% R.D. per 10°C
Response Time
25 ms typical at 12 bit resolution (50 ms max). The processing time is 6 ms typical at 12 bit resolution.
Gas Flow through Sensor (See Note 3)
≤ 63 mL/min
≤ 23 mL/min
≤ 100 mL/min
Interface
I2C
Case Material
PPS
Degree of Protection
IEC IP40
Withstand Pressure
10 kPa
Operating Temperature
-20 to 80°C (with no condensation or icing)
Operating Humidity
35 to 85% RH (with no condensation or icing)
Storage Temperature
-40 to 80°C (with no condensation or icing)
Storage Humidity
35 to 85% RH (with no condensation or icing)
Insulation Resistance
Between Sensor outer cover and lead terminals: 20 MΩ min. (at 500 VDC)
Dielectric Strength
Between Sensor outer cover and lead terminals: 500 VAC, 50/60 Hz min. for 1 min (leakage current: 1 mA max.)
Weight
5.2 g
Note: 1. At standard atmospheric pressure (1013.25 hPa).
2. Dry gas must not contain large particles, e.g., dust, oil or mist.
3. Type D6F-PH is based on thermal flow principle. Air flow is needed to measure the differential pressure. Typical characteristic of air flow
by differential pressure is shown in the “Engineering Data” section.
4. The zero point tolerance and span tolerance are independent uncertainties and add according to the principles of error propagation.
Communication
Method
Master/Slave
Slave / Address: HEX: 0x6C
BIN: 110_1100 (7 bit)
Fast Mode 400kHz
Speed mode
Signals
SCL
SDA
Serial Clock
Data Signal
Flow Rate (sccm)
I2C
50
40
30
20
10
0
-10
-20
-30
-40
-50
Relationship Between
Pressure and Flow Rate
-600
-400
-200
0
200
Pressure (Pa)
400
600
Note: Additional information can be found on the Omron website
Phone: 847-882-2288
www.components.omron.com
©2013 Omron Electronic Components LLC, Printed in U.S.A. 5/2013