Schurter DF12 Iec appliance inlet c14 or c18 with filter, circuit breaker ta45 Datasheet

DF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
IEC Appliance Inlet C14 or C18 with Filter, Circuit Breaker TA45 (recessed)
C14
C18
70° C
70° C
Approvals and Compliances
Description
- Panel Mount :
Screw-on mounting from front side
- 3 Functions :
Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole
, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
- All single elements are already wired
- Circuit Breaker non-illuminated or illuminated
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
-
Unwired versions
Other rocker marking
Medical version M80
Capacitance CX1
Variant with notch for V-Lock mating Cordsets
References
Alternative: version without line filter DF11
Substitute for type 5145
Alternative: Standard version
Weblinks
pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temperature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Material: Housing
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
Circuit Breakers
Line Filter
MTBF
C14 / C18 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I or II
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 100'000 h acc. to MIL-HB-217 F
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
EMC Products
1
DF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: DF12
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40012935
UL Approvals
UL
UL File Number: E72928
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
IEC 60939
Passive filters for suppressing electromagnetic interference
Designed according to
IEC 61058-1
Switches for appliances. Part 1. General requirements
Designed according to
UL 498
Standard for Attachment Plugs and Receptacles
Designed according to
UL 1283
Electromagnetic interference filters
Designed according to
CSA C22.2 no. 42
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Designed according to
CSA C22.2 no. 8
Electromagnetic interference (EMI) filters
Design
Standard
Description
Designed for applications acc.
IEC/UL 60950
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Designed for applications acc.
IEC 60601-1
Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS
SCHURTER AG
EU Directive RoHS 2011/65/EU
China RoHS
SCHURTER AG
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
REACH
SCHURTER AG
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
MicrositeV-Lock
SCHURTER AG
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
Medical Equipment
SCHURTER AG
Suitable for use in medical equipment according to IEC/UL 60601-1
Product standards
Product standards that are referenced
Organization
Application standards
Application standards where the product can be used
Organization
Compliances
The product complies with following Guide Lines
Identification
2
EMC Products
DF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Dimension [mm]
Screw-on Version
76.2
33.5
10.6
41.2
28.7
2.8
29.4
75.5 ±0.10
82.5 ±0.10
74.3
73.2
37.1
92.5
82.5
R
3.
05
36
R
Ø 6.4
9.7
47.2
29.8
3.
/M
3.5
0.8
Ø
±0.05
3
6
9.65
R6
.5
R
4.
7
5
3
3.
Ø 3.3
±0
R
9.2
R 2.8
10.15
9.7
21.1
.05
75
3.
30.8
±0.10
5.3
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
1
Standard
2 x 11
100
2.2
1
2
Standard
2x4
100
2.2
1
3
Standard
2 x 2.5
100
2.2
1
4
Standard
2 x 1.6
100
2.2
1
6
Standard
2 x 0.7
100
2.2
1
8
Standard
2 x 0.6
100
2.2
1
10
Standard
2 x 0.4
100
2.2
1
15
Standard
2 x 0.1
100
2.2
1
2
Medical (M5)
2x4
100
-
1
3
Medical (M5)
2 x 2.5
100
-
1
4
Medical (M5)
2 x 1.6
100
-
1
6
Medical (M5)
2 x 0.7
100
-
1
8
Medical (M5)
2 x 0.6
100
-
1
10
Medical (M5)
2 x 0.4
100
-
1
15
Medical (M5)
2 x 0.1
100
-
1
EMC Products
3
DF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Diagrams
Medical version (M5)
L’
L
P1
PE
Cy
Cx
N
L2
Cy
TA 45
L1
1)
PE’
N’
2)
PE
Cx
PE’
R
L2
N’
N
2)
P2
1) Line
2) Load
Attenuation Loss
- - - - 50Ω differential mode _____ 50Ω common mode
Standard version
1A
2A
3A
4A
6A
8A
10 A
15 A
1A
2A
3A
4A
6A
8A
10 A
15 A
Medical version (M5)
4
P1
L1
1)
P2
1) Line
2) Load
L’
L
TA 45
Standard version
EMC Products
DF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Table 1 Selection for type TA45
Order example
ABT
W
F
150
C0
• Circuit Breaker of Equipment
• 2-pole, rocker actuated
• Quick connect terminal
Other types on request
Diagram
Thermal overload protection
Without illumination
With illumination
1-pole
2-pole
P2
P2
P1
4
3
P1
3
6
220…240 V
110…120 V
ABT
ABD
A12
A14
A32
A34
}
Colours
Switch front
W
B
6
Rocker
black
black
black
white
black
–
–
–
orange transp.
Rocker legend
K
printed / bedruckt
OFF OFF
black / schwarz
L
printed / bedruckt
O
white / weiss
white / weiss
Position of the rocker legend
e.g F
Illustration
Colour of print
M
printed
O
O
printed / bedruckt
Surface
l
embossed / Relief
H
l
F
l
Colour of print
ON
Illustration
ON
Surface
black
P
printed
I
O
white
printed
I
O
black
R
Rated current circuit breaker of equipment
In
Code
In
Code
In
Code
In
Code
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,1
1,2
J01
J02
J03
J04
J05
J06
J07
J08
J09
J10
J11
J12
1,3
1,4
1,5
1,6
1,7
1,8
1,9
2,0
2,1
2,2
2,3
2,5
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J25
2,8
3,0
3,5
4,0
4,5
5,0
6,0
6,5
7,0
7,5
8,0
9,0
J28
030
035
040
045
050
060
065
070
075
080
090
10,0
11,0
12,0
13,0
14,0
15,0
20,0
100
110
120
130
140
150
200
Without release: code C0
Undervoltage release
P2
P1
U<
P2
Remote trip release
b
U<
P1
P2
ba
P1
P2
c P1
U<
U
E
Z
A
Code
Rated
voltage Un
•
•
•
•
2
240 V AC
•
•
•
•
3
230 V AC
•
•
•
•
4
120 V AC
EMC Products
5
DF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Technical data (continued)
Circuit breaker
Tripping characteristics
In >_ 3… <_ 15 A
Tripping characteristics
In < 3 A
[ min ] [ sec ]
10’000
[ min ] [ sec ]
10’000
Typ
TA45
Nennstrom
In < 3 A
60
2000
30
20
1000
10
Umgebungstemp.
1-polig geschützt
60
2-polig geschützt
30
5
I n > 3... < 15 A
1-polig geschützt
2-polig geschützt
1’000
10
500
TA45
2’000
20
+23 °C
Typ
Nennstrom
Umgebungstemp.
+23 °C
500
5
200
200
100
1
100
1
50
20
20
10
10
5
5
2
2
1
1
0,5
0,5
0,3
0,3
Auslösezeit
Auslösezeit
50
0,2
0,1
1,05 1,32
2
3
4
5
8
10
0,1
1,05 1,32
2
3
4
5
Nennstrom-Vielfaches
[ x In ]
Nennstrom-Vielfaches
0,2
8
10
[ x In ]
Effect of ambient temperature 1)
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below.
* Temperature must be measured at the rear of the breaker next
to the terminals after equipment operating temperature has been
reached.
* Ambient temperature [°C] Correction factor
–10
0,89
– 5
0,91
0
0,92
+23
1,00
+30
1,03
+40
1,08
+55
1,16
1) Example
Configuration code (example)
Type
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at
+ 40 °C ambient temperature
Optional Variants
00 standard
21 V-Lock notch
Order code TA 45
(2-pole rocker-switch
without accessories)
DF12 - ABTWF150C0 - 000 - 1111 - 00 - 21
see table 1
Colour
0 black
Mounting
0 Screw mounting
Terminal PE
0 without (PCII)
1 QC 6.3x0.8
Terminal L and N
1 QC 6.3x0.8, without connection to TA45
3 Connection to TA45 non insulated
Type of mains filter / capacitor / bleed resistor
1 standard
X2, Y2
with bleed resistor
3 medical M5
X2
with bleed resistor
Rated current
1 1A
2 2A
3 3A
4 4A
5 6A
6 8A
7 10A
9 15A
1) The rated current of the line-filter must be equal
or more than the rated current of TA45
Packaging unit
6
20 Pcs
EMC Products
1)
6,0 A
+40 °C
1,08
6 A x 1,08 = 6,5 A
DF12
Power Entry Modules with Line Filter
https://www.schurter.com /PG06
Accessories
Description
Assorted Covers
Rear Cover
0859.0109
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
Appliance Outlet further types to DF12
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4300-06
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4012
Connector further types to DF12
...
Mating Outlets/Connectors shuttered
Power Cord Overview complete
VAC13KS, Overview, diverse Connector IEC C13, cord end:
VAC13KS
02.12.2017
Power Cord further types to DF12
The specifications, descriptions and illustrations indicated in this document are based on current