Bel ABC300 Ite safety agency approval Datasheet

The ABC300 Series of open-frame power supplies, with its wide
universal 90-264 VAC input range and high power density, is available
at 300 W of output power and a variety of single output voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory approvals
for environmentally-friendly end products.
These power supplies are ideal for telecom, datacom, industrial
equipment and other applications.
•
5 x 3 x 1.5 inch form factor
•
200 W convection cooled
•
-20 to 50°C full load operation
•
No minimum load required
•
12 V fan & 5 V standby outputs
•
Inhibit & Power Good signals
•
IEC Protection Class Options:
o Class I: Earth pin J4 (no suffix)
o Class II: No Earth pin (-2 suffix)
•
Conducted EMI EN 55022-B, FCC Part 15 Level B
•
ITE Safety Agency Approvals
•
RoHS Compliant
•
CE marked
•
Instrumentation
•
Renewable Energy
•
Lighting
•
Test and Measurement
•
Industrial Applications
•
Robotics
•
Applied Computing
•
Wireless Communication
ABC300 Series
2
Screw Terminal
OUTPUT
VOLTAGE
5 VDC
MAX LOAD
CONVECTION 1,2,3
28.0 A
MAX LOAD
300 LFM 1,2,3
40.0 A
MINIMUM
LOAD
0.0 A
RIPPLE &
NOISE4
2%
TOTAL
REGULATION
± 2.5%
Screw Terminal
12 VDC
16.67 A
25.0 A
0.0 A
2%
± 2.5%
Screw Terminal
15 VDC
13.33 A
20.0 A
0.0 A
2%
± 2.5%
ABC300-1T24G
Screw Terminal
24 VDC
7.5 A
13.54 A
0.0 A
2%
± 2.5%
ABC300-1T30G
Screw Terminal
30 VDC
6.0 A
10.83 A
0.0 A
2%
± 2.5%
ABC300-1T48G
Screw Terminal
48 VDC
3.75 A
6.77 A
0.0 A
2%
± 2.5%
Cover-300-XCB5
Metal cover kit accessory
MODEL
CONNECTOR
ABC300-1T05G
ABC300-1T12G
ABC300-1T15G
Specifications are for nominal input voltage, 25°C unless otherwise stated.
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Input Voltage
Universal
90-264 VAC / 120-390 VDC
Input Frequency
Input Current
120 VAC
230 VAC
No Load Power
Inrush Current
Leakage Current
Switching Frequency
120 VAC
230 VAC
120 VAC
230 VAC
PFC converter (fixed)
Resonant converter (variable)
47 to 63 Hz
3.2 A max
1.65 A max
0.8 W
35 A max
65 A max
< 150 μA
< 300 μA
80 kHz typical
35 to 250 kHz, 90 kHz typical
1
Peak current rating on main output is 120% of max., lasting < 30 s with a maximum 10% duty cycle.
Combined output power of main output, fan supply and standby supply shall not exceed max. power rating.
3
Derate output power linearly to 80% from 90 VAC to 80 VAC input.
4
Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage
and load ranges.
5
When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
2
[email protected]
ABC300 Series
3
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Output Power6, 7
Derate linearly to 80% from 90 VAC to 80 VAC input.
120 VAC
230 VAC
120 / 230 VAC
120 VAC
230 VAC
200 to 325 W
88% typical
92% typical
10 ms
0.98
0.95
+/-0.5%
Efficiency
Hold Up Time
Power Factor
Line Regulation
Load Regulation
Transient Response
+/-2%
50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/μs,
< 10%, recovery time < 5 ms
Rise Time
< 100 ms
Set Point Tolerance8
± 1%
Voltage Output Adjustment
Over Voltage Protection
±3%
Automatic recovery
110 to 150 %
Over Current Protection
110 to 150 %
Short Circuit Protection
Short term, automatic recovery
Over Temperature Protection
Automatic Recovery
PARAMETER
DESCRIPTION / CONDITION
Power Good9
TTL signal goes high after main output is within regulation band, delay is 0.1 to 0.3 s
Remote On/ Off
To turn on PSU short remote pin to ground
Remote Sense
Compensates for 200 mV cable drop
Conducted Emissions
EN55032-B, CISPR22-B, FCC PART15-B
Pass
Radiated Emissions
EN 55032 A;
with external core (King core K5B RC 25x12x15-M in input cable)
Pass
Level B
Input Current Harmonics
EN 61000-3-2
Class D
Voltage Fluctuation and Flicker
EN 61000-3-3
Pass
ESD Immunity
EN 61000-4-2
Level 3, Criterion A
Radiated Field Immunity
EN 61000-4-3
Level 3, Criterion A
Electrical Fast Transient Immunity
EN 61000-4-4
Level 3, Criterion A
Surge Immunity
EN 61000-4-5
Level 3, Criterion A
Conducted Immunity
EN 61000-4-6
Level 3, Criterion A
Magnetic Field Immunity
EN 61000-4-8
Level 3, Criterion A
Voltage Dips, Interruptions
EN 61000-4-11
Criterion A & B
110° C primary heat sink
6
Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-30% and needs min. 1% load on main
output to be within regulation band. Ripple and noise is less than 10%.
7
The de-rating curves are valid for input voltages of 115VAC to 264 VAC. Below 115 VAC to 90 VAC the convection rating is 180 W max.
8
Standby output voltage tolerance including set point accuracy, line and load regulation is +/-10%. Ripple and noise is less than 5%.
9
Power good signal cannot be used as a current source. Internal pull up resistor from PG signal to 5 V is 10K.
It is recommended to use external transistor if intended to source current.
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00285_AE
Asia-Pacific
+86 755 298 85888
ABC300 Series
4
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
-20 to 70°C
Operating Temperature
Refer to de-rating curves (Fig. 1) to determine output power over
the entire operating temperature range.
Start-up is guaranteed
Reliability
Non Condensing
Operating:
Non-Operating:
MTBF according to Telcordia –SR332-issue 3
-20 to 0°C
-40 to 85° C
140 W max
200 W max
200 W max
300 W max
325 W max
95% Rh
10,000 ft.
40,000 ft.
1.77 million hours
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Isolation Voltage
4242 VDC min
Agency Approvals
Input to Output:
Approved to the latest edition of the following standards:
CSA/UL60950-1, EN60950-1 and IEC60950-1
Nemko, Nemko-CCL
CE mark
Complies with LVD Directive
Storage Temperature
5 V model
12 V, 15 V, 24 V, 30 V & 48 V models
5 V model
12 V and 15 V models
24 V, 30V and 48 V models
Convection:
Cooling
With 300LFM:
Relative Humidity
Altitude
Safety Standards
CONNECTOR
PIN
DESCRIPTION / CONDITION
AC Input Connector
J1
Pin 1
Pin 2
AC LINE
AC NEUTRAL
DC Output Connector
J2
Pin 1
Pin 2
RTN
V1
Signals & Aux Power10
J3
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Earth
J4
REMOTE ON/OFF
RTN
VFAN (+12 V/0.5 A)
-VE REMOTE SENSE
VSTBY (+5 V/2 A, +/-5%)
+VE REMOTE SENSE
RTN
POWER GOOD
Spade Connector
(Class I product only)
MANUFACTURER / PN
Molex: 26-60-4030
Mating: 09-50-3031; Pins: 08-50-0106
6-32 inches Screw Pan HD
Mating: Designed to accept Ring Tongue Terminal AMP : 8-31886-1,
wherein one 16 AWG (max) wire can be crimped.
Note: One Ring Tongue Terminal with 16 AWG is recommended for
current up to 11 A only.
Use multiple tongue terminals with wire for more current.
Molex: 22-23-2081
Mating: 22-01-2087; Pins: 08-50-0113
Molex: 19705-4301
Mating: 190030001
PARAMETER
DESCRIPTION / CONDITION
Weight
450 g (0.99 lbs)
Dimensions
127.0 x 76.2 x 38.1 mm (5.0 x 3.0 x 1.5 inch)
10
PSU is supplied with J3 housing, pin-1 and pin-2 shorted to enable main output without remote on/off feature.
[email protected]
ABC300 Series
5
Convection load: 140 W up to 40 °C
De-rate above 40 °C @ 1.67% per °C
Forced air cooled load: 200 W up to 40°C
De-rate above 40 °C @ 1.67% per °C
Convection load: 200 W up to 40 °C
De-rate between 40-50 °C @ 1% per °C
De-rate above 50 °C @ 2.5% per °C
Forced air cooled load: 300 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Convection load: 200 W up to 40 °C
De-rate between 40-50 °C @ 1% per °C
De-rate above 50 °C @ 2.5% per °C
Forced air cooled load: 325 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Figure 1. Derating Curves
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00285_AE
Asia-Pacific
+86 755 298 85888
ABC300 Series
6
Figure 2. Mechanical Drawing
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
1
Stand off, used to mount PCB has OD of 5.4 mm max.
2
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
3
Washer, if used, to have dia of 6.5 mm max.
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.