TSC GP1004 10.0 amps. glass passivated rectifier Datasheet

GP1001 - GP1007
10.0 AMPS. Glass Passivated Rectifiers
TO-220AB
Features
Glass passivated chip junction.
High efficiency, Low VF
High current capability
High reliability
High surge current capability
Low power loss
Mechanical Data
Cases: TO-220AB molded plastic
Epoxy: UL 94V-0 rate flame retardant
Terminals: Pure tin plated, lead free.
solderable per MIL-STD-202, Method 208
guaranteed
Polarity: As marked
High temperature soldering guaranteed:
o
260 C /10 seconds .16”,(4.06mm) from
case.
Weight: 2.24 grams
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25 oC ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
GP
GP
GP
GP
GP
GP Units
Symbol GP
1001 1002 1003 1004 1005 1006 1007
Maximum Recurrent Peak Reverse Voltage VRRM
50
100 200 400 600 800 1000
V
Maximum RMS Voltage
VRMS
35
70
140 280 420 560 700
V
Maximum DC Blocking Voltage
VDC
50
100 200 400 600 800 1000
V
Type Number
Maximum Average Forward Rectified
Current .375”(9.5mm) Lead Length
@TC = 100 oC
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@5.0A
I(AV)
10.0
A
IFSM
125
A
VF
1.1
V
5.0
200
30
3.0
- 65 to + 150
uA
uA
pF
o
C/W
o
C
Maximum DC Reverse Current @ TC=25 oC
at Rated DC Blocking Voltage @ TC=125 oC
IR
Typical Junction Capacitance ( Note 1)
Cj
RθJC
Operating and Storage Temperature Range TJ ,TSTG
1. Measured at 1 MHz and Applied Reverse Voltage of 4.0 Volts D.C.
Notes:
2. Thermal Resistance from Junction to Case Mounted on Heatsink size 2” x 3” x 0.25” Al-Plate.
Typical Thermal Resistance ( Note 2 )
Version: A06
RATINGS AND CHARACTERISTIC CURVES (GP1001 THRU GP1007)
FIG.1- MAXIMUM FORWARD CURRENT DERATING
CURVE
100
10
40
8
6
Single Phase
Half Wave 60Hz
Resistive of
Inductive Load
4
2
0
50
100
150
o
CASE TEMPERATURE. ( C)
INSTANTANEOUS REVERSE CURRENT. ( A)
AVERAGE FORWARD CURRENT. (A)
12
FIG.2- TYPICAL REVERSE CHARACTERISTICS
PER LEG
FIG.3- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
10
Tj=125 0C
4
2
1.0
Tj=25 0C
.4
.2
PEAK FORWARD SURGE CURRENT. (A)
175
.1
150
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
125
100
8.3ms Single Half Sine Wave
JEDEC Method
75
50
FIG.5- TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
25
400
0
1
2
5
10
20
50
100
200
NUMBER OF CYCLES AT 60Hz
INSTANTANEOUS FORWARD CURRENT. (A)
100
FIG.4- TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE.(pF)
120
100
80
60
40
f=10 MHz
Vsig 50Mvp-p
Tj=25 0C
40
20
10
4
Tj=25oC
Pulse Width=300 s
1% Duty Cycle
2
1
0.4
20
0.2
0
0.1
0.5
1.0
4
10
40
REVERSE VOLTAGE. (V)
100
400
1000
0.1
.6
.8
1.0
1.2
1.4
1.6
1.8
2.0
FORWARD VOLTAGE. (V)
Version: A06