PACELEADER MBR20200FCT 20.0a schottky barrier rectifiers 200v Datasheet

MBR20200FCT
20.0A SCHOTTKY BARRIER RECTIFIERS 200V
ITO-220
Features
•
•
•
•
x
.406(10.30) .138(3.50)
.118(3.00)
.382(9.70)
High Junction Temperature Capability
Low Forward Voltage
Pb-Free package is available
RoHS product for packing code suffix ”G”
Halogen free product for packing code suffix “H”
Case Material: Molded Plastic. UL Flammability
Classification Rating 94V-0 and MSL Rating 1
.114(2.90)
.098(2.50)
.642(16.30)
Marking : type number
.571(14.50)
Maximum Ratings
•
•
.171(4.35)
.067(1.70)
Operating Junction Temperature: -50°C to +150°C
Storage Temperature: -50°C to +150°C
Catalog
Number
MBR20200FCT
Maximum
Recurrent
Peak Reverse
Voltage
200V
Maximum
RMS
Voltage
140V
.138(3.50)
.039(1.00)
Maximum
DC
Blocking
Voltage
200V
.035(1.00)
.022(0.55)
MAX.(1.80)
.108(2.75)
.091(2.30)
.189(4.80)
.169(4.30)
.134(3.40)
.110(2.54)
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IF(AV)
20 A
TC = 115°C
IFSM
150A
8.3ms, half sine
VF
.95V
IF = 10A;
TJ = 25°C
.80V
IF = 10A;
TJ = 125°C
.114(2.90)
.098(2.50)
.560(14.22)
.492(12.50)
IR
50uA
TJ = 25°C
.031(0.80)
.015(0.38)
Notes:1.High Temperature Solder Exemption Applied, see EU Directive Annex 7.
Dimensions in inches and (millimeters)
1
www.paceleader.tw
MBR20200FCT
20.0A SCHOTTKY BARRIER RECTIFIERS 200V
Figure 1
Typical Forward Characteristics
Figure 2
Typical Reverse Characteristics
100
10000
50
TJ = 150°C
1000
TJ = 125°C
20
100
TJ = 100°C
Amps
uAmps
10
5.0
10
1.0
25°C
2.0
1.0
TJ = 25°C
0.1
0
0.4
0.2
0.6
0.8
1.0
0.01
20
0
40 60
80 100 120 140 160 180 200
Volts
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current- MicroAmperes versus
Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
24
Figure 4
Peak Forward Surge Current
150
20
125
16
100
75
12
Amps
Amps
50
8
25
4
0
0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
25
50
75
100
125
4
6
8 10
20
40
60 80 100
Cycles
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
2
2
150
°C