FUJITSU S190

S190 BUSINESS SERVERS
Issue
November
S190-30, -40, -65, -80, -100, -120, -140, -150
Pages
4
The S190 Business Server models form a series of powerful computers specifically
designed for commercial applications. They run under the BS2000/OSD operating
system, which supports especially in the operating mode OLTP for the secure
handling of e-business application and batch processing. Highlights of the S190
Business Server range are its small footprint, its energy savings and its quiet
operation, thanks to the use of VLSI (Very Large Scale Integrated) CMOS
technology with Cu bonding and single chip modules, as well as compact rackmount technology.
The S190 Series consists of the following models: S190-30
(three CPUs), the S190-40 (four CPUs), S190-65 (six CPUs),
S190-80 (eight CPUs), S190-100 (ten CPUs), S190-120
(twelve CPUs) S190-140 (fourteen CPUs) and S190-150
(fifteen CPUs).
All models of the S190 series come with a spare CPU which,
in case of a CPU failure, will be activated dynamically to
replace the failed CPU. The data processing is thus continued
without interruption or performance degradation.
With OSD V5.0 (or higher) additional CPUs can be added or
removed dynamically while the system is running (Capacity
on Demand)
Field installation of upgrades can easily performed.
The S190 models support programs with virtual 31- or 24-bit
addresses.
A characteristic feature of new applications is the use of larger
and larger address spaces as a result of the implementation
of complex functions, object-oriented programming systems
and advanced program development methods.
When large address spaces are accessed by many tasks, an
appropriately large main memory capacity is required in order
to avoid intensive paging. At the same time there is an
increased requirement for main memory resources to support
input/ output caching in order to speed up file accesses in
performance-critical applications and increase input/output
throughput. In addition to ESA addressing, therefore, the
models in the S190 series provide a further addressing mode,
called the Real Address Extension Feature: With this, a virtual
address (31-bit) is converted with hardware support into an
extended real address (40-bit).
The main memory capacity of the models S190-30 and -40
can be expanded to 32 Gbytes and of the models
S190-65,-80, -100, -120, -140, -150 to 64 Gbytes.
For the increase of
throughput and access
to performance-critical
data a shared Global
Storage (GS) is
available optionaily. The
GS can be upgraded to
ma x 64B in size.
Two independently usable GS units, each with a capacity of
max. 64 Gbytes as well as remote installation (max. 70 m),
increase the fail-safe aracteristics of high-speed memory.
The GS units are directly connected to the computer-internal
memory control unit via fiber-optic cable.
Two optional GS battery units provide backup power to
ensure that the data in the GS is not lost as a result of a
mains power outage.
The input/output system (dynamic channel subsystem) offers
extensive and flexible expansion options. It is possible to
configure up to four input/output processors, providing a total
of max. 256 channels for connection of peripheral devices
with Type 2, Type S, Type F or Type FC channel interfaces.
In addition, thanks to the Type S channel converter, users are
assured of a flexible entry into Type S channel technology
while at the same time safe-guarding their existing
investment.
The service processor (SVP) and the external service/console
processor jointly support operation, monitoring, diagnostics
and maintenance of the computer, as well as TELESERVICE.
For the increase of the capability and the availability a number
of models of the S-series to a HIPLEX cluster can be
configured.
Data Sheet ⏐ Issue: November⏐ S190 BUSINESS SERVERS
Page 2 / 4
CENTRAL PROCESSORS
GLOBAL STORAGE
Model
Centralprocessors
S190-30
S190-40
S190-65
S190-80
S190-100
S190-120
S190-140
S190-150
1)
3
4
6
8
10
12
14
15
Per central processor
First-level cache (KB)
Second-level cache (Mbytes)
Addressing width (bit)
ESA addressing for dataspaces
Real address extension feature
256
2
24/31
yes
yes
INPUT/OUTPUT SYSTEM
Input/output processors
S190-30, -40, -65, -80, -100, -120, -140, -150
Module type
Type 2 channels
Type S channels
Type F channels
Type FC channels
GS module
Type A+B
Type B+C
A
128
B
256
C
512
Memory configuration (GB)
2, 3, 4, 6, 8
8, 12, 16, 24, 32, 48, 64
1) Symmetrical expansion of GS units A + B required.
SERVICE PROCESSOR
Optional port:
•
1 service processor LAN (CSMA/CD, 10Base-T)
max 4
Channels/increment
max. 64/4
max. 256/8 1)
max. 60/2
max. 32/2
Maximum data rates
Input/output processor
1.8 (GB/s)
Type 2 channel
Block multiplexer mode
4.5 (MB/s)
Type S channel
CNC, CTC mode
CVC mode
17 (MB/s)
4.5 (MB/s)
Type F/FC channel
Bridge mode/ FC mode
GS unit A and GS unit B
GS module type
Chip technology (Mbit)
Ports in basic configuration:
•
1 service processor LAN (CSMA/CD, 10Base-T)
•
1 service interface (FST)
•
1 Business Server S190 On/Off
1) All models are equipped with one hot-spare CPU.
Model
Number
0, 1, 2
0, 1, 2
yes 1)
max. 24
Global Storage units
Battery cabinets
Dual-write mode
Battery operation (h)
SERVICE/CONSOLE PROCESSOR
Based on a PC server with ports for:
•
1 main console ( monitor, keyboard, mouse)
•
1 printer with parallel interfaces
•
1 V.24 device (radio clock, ATOP, console)
•
1 TELESERVICE modem (V.24)
•
2 service processor LAN (CSMA/CD, 10Base-T)
•
1 channel type S of the basic cabinet
Optional ports for:
•
Max. 8 V.24- devices
TYPE S CHANNEL CONVERTER
100 (MB/s) full duplex
1) 1 type S channel is required for connection of the service/
console processor.
Ports for:
Type S Channel
1)
Type 2 Channel
Number
2
2
1) For connection of peripherals; block multiplex mode
(data rate: 4.5 MB/s max.).
ON/OFF POWER CONTROL
Power Control Interface
PCI
ECI 1)
OCI
1) For power on/off control of GS.
Interfaces/increment
32 to 56/8
8
0; 2
MAIN MEMORY
Model
S190-30, -40,
S190-65, -80, -100, -120, -140, -150
MM Module No.
2
4
Memory Capacity (GB)
MM Module Type A
Type B
4, 8, 12, 16
8, 12, 16, 24, 32
4, 8, 12, 16, 24, 32
16, 24, 32, 48, 64
Data Sheet ⏐ Issue: November⏐ S190 BUSINESS SERVERS
Page 3 / 4
Installation Data:
Electrical
Rated voltage (V)
Rated frequency (Hz)
Power
Power consumption (kVA)
Effective Power (kW)
Fuse rating (A)
Connection type
Cabinet 1
1)
Cabinet 3to 6 1)
3x 200 – 240 ±10%
50/60 ±1
200 – 240 ±10%
50/60 ±1
Cabinet 1 1)
6.65)
1.8
30
2)
3x 3wire
Cabinet 3,4 1)
-
1.3
0.96
10
3-wire 2)
1)
Physical
Cabinet 1
Height (mm)
Width (mm)
Depth (mm)
Weight (kg)
Footprint (W x D) (mm) 3)
1800
1670
936
1000
1670 x 2450
Cabinet 3,4 1)
1800
1280
936
400
2450 x 1214
Noise emission
Sound pressure level
at workplace (dB(A))
Cabinet 1 to 6
Environmental
Cabinet 1 to 6
Operating environment to
DIN IEC 721
Temperature (°C)
Rel. humidity (%)
COMPLIANCE WITH STANDARDS
Safety
Radiation emission, RFI suppression
CE mark in accordance with EU Directive
Cabinet 5,6 1)
0.8
0.73
10
3-wire 2)
Cabinet 5,6 1)
1800
680
850
180
2680 x 2850
1)
≤60
1)
class 3K2
15 – 32
20 4) – 75
Cabinet 1 to 6
2)
EN 60950
In preparation: UL 1950 protection class 1
EN 55022 A, EN 50082-1 and EN 6100-3-2/3
In preparation: FCC class A
89/336/EEC (RFI) and 73/23/EEC (product safety)
1) Cabinet 1: Basic cabinet (2 frames; central processors, input/output processors, channels, SVP, PCI)
Cabinet 2 Global Storage (Unit A)
Cabinet 3 Global Storage (Unit B)
Cabinet 4 Battery for Global Storage Unit A
Cabinet 5 Battery for Global Storage Unit B
2) Permanently wired connection to commercially available power distributor or 3911 Power Distributor required.
3) Installation area incl. space for operating and maintenance access
4) Limited range compared to 3K2
5) Power consumption for max. configuration
Data Sheet ⏐ Issue: November⏐ S190 BUSINESS SERVERS
Page 4 / 4
Installation Data:
SCP
3970-2xx
OCI Converter
S180P-E65
TYPE S Channel Converter
3954-2
200 – 240 ±10%
50/60 ±1%
200 – 240 ±10%
50/60 ±1%
200 – 240 ±10%
50/60 ±1%
0.65
0.5
2x 10
2x 3-wire/grounding
outlet
0.1
0.05
10
3- wire/grounding
outlet
0.15
0.12
10
3- wire/grounding
outlet
460
280
685
20
280 x 685
159
500
580
20
2080 x 700
135
425
480
15
525 x 2080
≤40
-
≤50
Electrical
Rated voltage (V)
Rated frequency (Hz)
Power
Power consumption (kVA)
Effective power (kW)
Fuse rating (A)
Connection
Physical
Height (mm)
Width (mm)
Depth (mm)
Weight (kg)
Footprint (W x D) (mm) 1)
Noise Emission Values
Sound pressure level at workplace (dB(A)
Environmental
Operating environment to DIN IEC 721
Temperature (°C)
Rel. humidity (%)
COMPLIANCE WHITH STANDARDS
Safety
Radiation emissions, RFI suppression
CE mark in accordance with EU
Directive
Class 3K2
15 – 32
10 – 75
Class 3K2
15 – 32
20 2) – 75
SCP
OCI Converter + TYPE S Channel Converter
EN 60950
UL 1950 Protection
Class 1
EN 60950
In preparation:
UL 1950 Protection Class 1
EN 55022 B,
EN 50082-1
FCC Class A
EN 55022 B and EN 50082-1
In preparation: FCC Class A
89/336/EEC (RFI) (EMC) and 73/23/EEC (product safety)
1) Installation area incl. space for operating and maintenance access
2) Limited range compared to 3K2
All rights, including rights created by patent grant or registration of a utility model or design as well
as rights of technical modifications are reserved. Delivery subject to availability. Designations may
be trademarks, the use of which by third parties for their own purposes may violate the rights of the
trademark owners.
Copyright © Fujitsu Siemens Computers, 08/2004
Published by
Fujitsu Siemens Computers
http://www.fujitsu-siemens.com/
Company stamp