Hirose LF10-WBR-4S Miniature waterproof shielded connector Datasheet

The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
NEW
Miniature Waterproof Shielded Connectors
LF Series
Mated dimensions
8.9 mm max. (3 pos.)
Ø13
36.4
Receptacle
Plug
Short turn bayonet lock
Mating:
Insert the plug, and then turn the locking collar clockwise,
as indicated by the coupling direction marking.
■Features
1. Ease of shielded termination and connector
assembly
All components are self-aligning and do not require complex
assembly tooling. The shield of the cable is connected with the
metal housing of the connector using simple shielding clamp,
supplied with the connector.
Receptacle
Locking collar
Coupling direction marking
Plug
Un-mating:
Turn the locking collar counter-clockwise
than pull off the plug.
2. Water and dust protected
IP67 protection rating. Complete protection against dust
penetration and against water penetration when mated
assembly is submerged at the depth of 1.8 meter for 48 hours.
Coupling direction marking
3. Bayonet lock
Short turn bayonet lock assures secure vibration resistant
mating of the connectors.
4. High current rating capacity
Number of contacts
Current rating
3
5A max.
4
10A max.
6, 12 and 20
2A max.
11
Shielding Connection - Plug
Built-in shield
connection spring
Cable shielding connection clamp
Cable
10A max.
2A max.
5. RoHS compliant
All components and materials comply with the requirements of
the EU Directive 2002/95/EC.
■Applications
Sensors, robots, injection molding machines, NC, factory
automation equipment, surveying instruments, measuring
instruments, medical equipment, surveillance cameras and
base stations.
2008.5
1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS
products
have been discontinued,
or will be discontinued
soon.Connectors
Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF
Series●Miniature
Waterproof
Shielded
■Product Specifications
Voltage rating
Rating
Current rating
Operating temperature range
Storage temperature range
Item
125V AC, 175V DC (3 pos.)
125V AC, 125V DC (4 pos.)
30V AC, 42V DC (6 pos. , 12pos. , 20pos.)
125V AC,
DC (11 pos. A to D)
30V AC, 42V DC (11 pos. 1 to 7)
5A max. (3 pos.)
10A max. (4 pos.)
2A max. (6 pos. , 12pos. , 20pos.)
10A(11 pos. A to D), 2A(11 pos. 1 to 7)
–25ç to +85ç (Note 1)
–25ç to +85ç (Note 2)
Specification
11.Contact resistance
Conditions
15 mø max. (3, 6, 12, 20 pos.)
15 mø max. (4 pos.)
15 mø max. (A to D), 15mø max. (1 to 7)(11 pos.)
12.Insulation resistance
1000 Mø min.
13.Withstanding voltage
No flashover or insulation breakdown.
500V DC (3, 4 pos.)
100V DC (6, 12, 20 pos.)
500V DC (A to D), 100V DC (1 to 7)(11pos.)
1250V AC/one minute (3, 4 pos.)
300V AC/one minute (6, 12, 20 pos.)
1250V AC(A to D),300V AC(1 to 7) / one minute(11pos.)
Frequency: 10 to 500Hz, single amplitude of 0.75mm,
14.Vibration
No electrical discontinuity for 10μs max.
15.Shock
No electrical discontinuity for 10μs max.
16.Durability
16.(Mating/un-mating)
30 mø max. (3, 6, 12, 20 pos.)
10 mø max. (4 pos.)
10 mø max.(A to D), 30 mø max.(1 to 7)(11pos.)
17.Temperature cycle
Insulation resistance: 100 Mø min.
acceleration of 98 m/s2 for 3 hours in 3 axis.
Acceleration of 490m/s2, 11ms duration,
sine half-wave waveform, 3 cycles in each of the 3 axis.
Insulation resistance: 100 Mø min. (Dray state)
19.Water / dust protection
When mated with corresponding connector.
1000 cycles
Temperature: -55ç ➝ Room temperature ➝ +125ç ➝ Room temperature
Time: 30 ➝ 10 to 15 ➝ 30 ➝ 10 to 15 (minutes) 5 cycles
Insulation resistance: 110 Mø min. (When temperature high)
18.Humidity
1A DC
96 hours at temperature of 40ç and humidity of 90% to 95%.
Complete dust protection. No water penetration
when submerged for 48 hours at the depth of 1.8 meter.
Note 1: Includes temperature rise caused by the current flow.
Note 2: The term “storage” refers to products stored for long period of time prior to mounting and use. Operating temperature range
and humidity range covers non-conducting condition of installed connectors in storage, shipment or during transportation.
■Materials / Finish
Components
Material
Finish / Color
Remarks
Body / back shell
Zinc alloy
Nickel plated
––––––––––
Insulator
PPS
Black
UL94V-0
Contacts
Copper alloy
Gold plated
––––––––––
Gasket
Chloroprene rubber
Black
––––––––––
■Ordering Information
1 Series name
2 Shell size
LF 07 - W B P - 6 S
1
2
3
4
5
6
7
3 Waterproof
4 Lock Mechanism
5 Connector type
6 Number of contacts
7 Contact type
2
: LF
07
10
13
W : Waterproof type
B : Bayonet lock
P : Plug
R : Receptacle
J : Jack
: 3, 4, 6, 11, 12, 20
P : Male contact
S : Female contact
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHSLF
search
at www.hirose-connectors.com,
or contact
your Hirose
sales representative.
Series●Miniature
Waterproof
Shielded
Connectors
(Cable dia.)
■Plugs
ØA
ØC
B
(Shown one example)
Unit:mm
Part number
CL No.
Contact
LF07WBP-3S
LF07WBP-3P
LF07WBP-6S
LF07WBP-6P
LF10WBP-4S
LF10WBP-4P
LF10WBP-12S
LF10WBP-12P
LF13WBP-20S
LF13WBP-20P
LF13WBP-11S
LF13WBP-11P
136-0003-7
136-0004-0
136-0001-1
136-0002-4
136-0005-2
136-0006-5
136-0007-8
136-0008-0
136-0009-3
136-0010-2
136-0011-5
136-0012-8
Female
Male
Female
Male
Female
Male
Female
Male
Female
Male
Female
Male
Number of contacts
ØA
B
ØC
Weight RoHS
12.3
35.3
5
11g
14.8
41.8
7.3
17g
17.9
51.9
8.7
29g
3
6
4
YES
12
20
11
■Receptacles
C
ØB
ØA
D
F(HEX)
E
(Shown one example)
Unit:mm
Part number
CL No.
Contact
LF07WBR-3P
LF07WBR-3S
LF07WBR-6P
LF07WBR-6S
LF10WBR-4P
LF10WBR-4S
LF10WBR-12P
LF10WBR-12S
LF13WBR-20P
LF13WBR-20S
LF13WBR-11P
LF13WBR-11S
136-1003-2
136-1004-5
136-1001-7
136-1002-0
136-1005-8
136-1006-0
136-1007-3
136-1008-6
136-1009-9
136-1010-8
136-1011-0
136-1012-3
Male
Female
Male
Female
Male
Female
Male
Female
Male
Female
Male
Female
Number of contacts
ØA
ØB
3
ØC
C
D
E
F
7.65
1M9∞0.75
11
7.75
M11∞0.75
13
7.75
M14∞0.75
17
Weight RoHS
15.15
10.3
13
12.8
15.3
6
4
15.05
15.25
19.05
12
6g
17.25
20
15.9
18.3
19.05
4g
11
5g
6g
9g
10g
9g
10g
YES
Note: Recommended hex nut tightening torque: 1.5 to 2 N·m (3,4,6, and 12 pos.), 2 to 2.5 N·m (11, 20 pos.)
3
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS
products
have been discontinued,
or will be discontinued
soon.Connectors
Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF
Series●Miniature
Waterproof
Shielded
ØD (Cable dia.)
■Jacks
ØB
ØA
C
(Shown one example)
Unit:mm
4
Part number
CL No.
Contact
LF07WBJ-3P
136-2003-8
Male
LF07WBJ-3S
136-2004-0
Female
LF07WBJ-6P
136-2001-2
Male
LF07WBJ-6S
136-2002-5
Female
LF10WBJ-4P
136-2005-3
Male
LF10WBJ-4S
136-2006-6
Female
LF10WBJ-12P
136-2007-9
Male
LF10WBJ-12S
136-2008-1
Female
LF13WBJ-20P
136-2009-4
Male
LF13WBJ-20S
136-2010-3
Female
LF13WBJ-11P
136-2011-6
Male
LF13WBJ-11S
136-2012-9
Female
Number of contacts
ØA
ØB
C
ØD
Weight RoHS
10.3
11.5
36.3
5.0
11g
12.8
13.8
42.4
7.3
16g
3
6
4
12
29g
20
15.9
11
16.9
52.4
8.7
30g
29g
30g
YES
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHSLF
search
at www.hirose-connectors.com,
or contact
your Hirose
sales representative.
Series●Miniature
Waterproof
Shielded
Connectors
■Applicable tools
Unit:mm
Description
Part number
Manual cable clamp crimp
CL No.
LF07BP-T01
LF07BJ-T01
LF10BP-T01
LF10BJ-T01
LF13BP-T01
LF13BJ-T01
150-0232-0
150-0233-3
150-0235-9
150-0236-1
150-0237-4
150-0238-7
LF series Applicable cable dia.
5 (Note)
150-0234-6
7.3 · 8.7
LF-TC-01
Note: Applicable cable dia. is only 5mm for LF series.
■Solder termination fixture
Part number
CL No.
HR10A-TC-02 150-0041-2
Applicable connectors
LF07WBP-6S,6P,3S,3P
LF07WBJ-6S,6P,3S,3P
LF10WBP-4S,4P,12S,12P
LF10WBJ-4S,4P,12S,12P
LF13WBP-20S,20P,11S,11P
LF13WBJ-20S,20P,11S,11P
5
.0
+0 0
A
■Panel Cutout
Alignment guide
unit (mm)
B
Panel thickness
LF07
Ø9.05
8.1
0.5 to 2
LF10
Ø11.05
10.2
0.7 to 2
LF13
Ø14.05
13.1
0.7 to 2
Shell size
B
+0.05
0
A
■Contact position arrangement and specifications
Shell size
LF07
LF10
LF13
Contact configuration
3
1
5
2
1
8
3
3
2
7 12 11 3
6
5 4
10
Number of contacts
3
6
4
12
Withstanding voltage
1250V AC
300V AC
1250V AC
300V AC
Current rating
5A
2A
10A
2A
Insulation resistance
1000Mø
1000Mø
1000Mø
Contact resistance
15mø
5mø
15mø
1.7mm
0.8mm
Solder pot inner diameter
1.15mm
0.8mm
B
2
4
2
4
1
1
9
1
6
C
A
2
D
2
1
5
3
6
4
7
11
4
AC1250V
4
10A
7
4
8
5
9 10
11 12 13 14 15
16 17 18 19
20
20
7
AC300V
7
2A
1000Mø
4
5mø
4
Ø1.7
6
3
7
15mø
7
Ø0.8
AC300V
2A
1000Mø
4mø
0.8mm
Note 1: The contact configuration as viewed from the female contact connector mating side.
Note 2: The ▼ symbol indicates polarizing key position.
Note 3: Withstanding voltages are test voltage values.
5
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS
products
have been discontinued,
or will be discontinued
soon.Connectors
Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF
Series●Miniature
Waterproof
Shielded
■Termination and Assembly Instructions
The connectors are delivered with pre-assembed condition and the disassembly as shown No.1.
1
Operation
Illustration
No.
Solder termination fixture
1
Plug
Plug disassembly
1
Insert the plug into securely held solder
termination fixture as shown.
Fixture Part No.
Applicable connector
LF07BP-T01 LF07WBP-6S,6P,3S,3P
LF10BP-T01 LF10WBP-4S,4P,12S,12P
LF13BP-T01 LF13WBP-20S,20P,11S,11P
Locking collar
Insertion direction
2
1
Body / insulator assembly
2
Backshell
Solder termination fixture
Jack
Loosen the backshell turning it counter
clockwise and remove it from the body/
insulator assembly.
Jack Disassembly
1
Insert the jack into the securely held solder
termination fixture as shown.
Fixture Part No.
Applicable connector
LF07BJ-T01 LF07WBJ-6S,6P,3S,3P
LF10BJ-T01 LF10WBJ-4S,4P,12S,12P
LF13BJ-T01 LF13WBJ-20S,20P,11S,11P
Insertion direction
2
Body / insulator assembly
2
Backshell
2
1
Connector Assembly
Backshell
1
Threaded section
Threaded section
Tightening collar
6
Loosen the backshell turning it
counterclockwise.
Apply a coating of Loctite 7649
(Manufactured by Henckel Japan, Ltd,)
primer to the threaded sections of the
backshell and the tightening collar.
Completely dry the coated surfaces.
Note
(1) Drying time at room temperature is
approximately 30 to 70 seconds.
(2) Ensure sufficient ventilation of the area at
time of drying.
(3) Take necessary steps to protect the coated
surfaces from contamination.
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHSLF
search
at www.hirose-connectors.com,
or contact
your Hirose
sales representative.
Series●Miniature
Waterproof
Shielded
Connectors
2
Operation
Illustration
No.
2
2
Strain relief collar
Backshell
Tightening collar
3
A
1
Cable
Seal bushing
Cable preparation end
Cable preparation
Cable outer jacket
1
Shielding mesh
11
20
A mm
8 to 9
13 to 14
14 to 15
22 to 23 (No.A to D)
23 to 24 (No.1 to 7)
23 to 24
2
Shielding mesh
Wires
Strip the cable’s outer jacket to the dimensions
illustrated in the table 1.
Note
Table 1. Stripping Dimensions
Number of Conductors
3
6
4
12
Thread the tightening collar, strain relief collar,
seal bushing and the backshell over the cable
as illustrated.
(1) Exercise caution not to damage the shielding
mesh.
(2) Any damage to the cable’s outer jacket may
affect the waterproof performance of the
assembled connector.
2
Fold back the shielding mesh over the cable’s
outer jacket assuring that it is uniform on its
diameter.
3
Strip the wires to the dimensions illustrated in
the Table 2.
Cable outer jacket
Shielding mesh
(Folded back)
4 to 5mm
Wires
Cable outer jacket
Stripping dimensions
3
Cable outer jacket
B
Wires
Note
When stripping the wires exercise caution not
to damage it’s insulation, folded over
shielding mesh or cable’s outer jacket.
Conductors
Table 2. Stripping Dimensions
Number of Conductors
3
6
4
12
11
20
B mm
2.5±0.5
2±0.5
3±0.5
2±0.5
3±0.5 (No.A to D)
2±0.5 (No.1 to 7)
2±0.5
7
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS
products
have been discontinued,
or will be discontinued
soon.Connectors
Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF
Series●Miniature
Waterproof
Shielded
Operation
Illustration
No.
Soldering
4
1
Soldering conditions
Soldering iron tip temperature: 350±10ç
Soldering time: within 5 sec.
Note
(1) Assure that the solder compound is
sufficiently melted on the soldering iron tip.
(2) When applying, make sure that the solder will
flow correctly at all the contact surfaces
between the conductor and the contact.
2
Cmm
–1
2
Wire
Insulator
Contact
Table 3
Number of
Conductors
Number of
contacts
C mm
6
1 to 6
1 to 9
10 to 12
1 to 5,16 to 20
6 to 15
1 to 4
5 to 7
4
4
6
4
6
6
4
12
Heat-shrink tubing
20
11
2
Insulator
–2
Insulator
Insulator wall
Contact
Contact Insulator wall
Wire insulation
– 1 6, 12, 20, 11(No.1〜7) Conductors
(1) Place a heat-shrink tubing (inside diameter of
1.1 mm min.) over every other wire.
Perform the soldering of the contact and the
(2) conductor, with the wire’s insulation touching
the contact as shown.
After soldering, slide the heat shrink tubing
(3) over the soldered joint and shrink it. The
tubing should touch the insulator as shown.
2
– 2 3, 4, 11(No.A〜D) Conductors
(1) Perform the soldering of the contact and the
conductor, with the wire’s insulation touching
the contact as illustrated.
(2) When soldering, to maintain the insulation
between adjacent contacts. Make sure that
the wire’s insulation remains below the edge
of the insulator’s wall 0.5 mm min., as
illustrated.
Wire insulation
Solder
3
0.5 mm min.
D
Cable outer jacket
3
After the soldering, keep a distance of D
between the contact end and the cable’s
outer jacket as illustrated.
Note
Shielding mesh
(Folded back)
Table 4. Wire Dimensions
Number of Conductors
3
6
4
12
11
20
8
D mm
6 to 7
10 to 11
13 to 14
18 to 19
The distance of D is required in order to
assure correct assembly of the backshell.
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHSLF
search
at www.hirose-connectors.com,
or contact
your Hirose
sales representative.
Series●Miniature
Waterproof
Shielded
Connectors
Crimping of the Shielding Clamp
1
Solder termination fixture
Body / insulator assembly
1
After completion of the soldering operations
carefully remove (holding on the locking collar)
the body/insulator assembly from the solder
termination fixture.
Note
Soldered joints
2
Cable outer jacket
Exercise caution not to damage or deform the
solder joints.
2
Cable outer jacket
Wires
Shielding mesh
Copper tape
2 mm
max.
5
Operation
Illustration
No.
Note
5 to 6mm
Copper tape
After wrapping the copper tape, the tape
should overlap itself by 2 mm max.
3
3
Cable outer jacket
Ground clamp
Wrap the folded over shielding mesh with 5 to
6 mm wide copper tape to assure that it will
not become loose.
Apply the copper tape so that the shielding
mesh does not protrude from under it.
1±0.5mm
Copper tape
Cable outer jacket
Copper tape
Insert the “U” shaped shielding clamp over the
copper tape as shown on the illustration.
It is critical that the overlap of the copper tape
is located inside the shielding clamp as shown
on the illustration.
Note
Wires
When the end of the copper tape wrapping is
positioned at the open side of the ground
fitting, the end portion of the copper tape
wrapping will no longer be covered by the
ground fitting when the ground fitting is
crimped.
Shielding clamp
Shielding mesh
Overlap of the copper tape
4
4
Commercially
available pliers
E
Table 5
Shell size
Shielding clamp
Overlap of the copper tape
LF07
LF10
LF13
Using commercially available pliers bend the
open ends of the shielding clamp as illustrated,
assuring that it stays in place. The dimension
of E. between opposing edges of the shielding
clamp is necessary to assure correct final
crimp.
E
5mm max.
7mm max.
9
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS
products
have been discontinued,
or will be discontinued
soon.Connectors
Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF
Series●Miniature
Waterproof
Shielded
5
Operation
Illustration
No.
5
Crimping tool
Forming cavity
5
Both sides of the shielding clamp must be
placed in the forming cavity of the tool
(as shown on the illustration) and crimped
over the cable by closing the tool completely.
Crimping tool Forming cavity
6
1
,
7.0
5.3
HR10A-TC-02
LF-TC-01
5.3
Applicable cable
diameter
Shielding clamp
diameter after crimping
5mm
5.3mm to
5.5mm
7.0
–––
–––
7.9
7.3mm
9.1
8.7mm
7.9mm to
8.1mm
9.1mm to
9.3mm
Connector Assembly
2
Threaded section
1
Backshell
Place the body/insulator assembly in the
applicable solder termination fixture.
For plug assembly
Fixture Part No.
LF07BP-T01
LF10BP-T01
LF13BP-T01
Applicable connector
LF07WBP-6S,6P,3S,3P
LF10WBP-4S,4P,12S,12P
LF13WBP-20S,20P,11S,11P
For jack assembly
Fixture Part No.
LF07BJ-T01
LF10BJ-T01
LF13BJ-T01
2
Wrench width : D
Table 6
Shell size Tightening torque Wrench width
LF07
LF10
LF13
3
,
4
1N·m~1.5N·m
1N·m~1.5N·m
10mm
1.5N·m~2N·m
16mm
13mm
Groove
Protrusion
It is critical that the cable itself will not turn or
twist during this operation.
3
Slide forward the seal bushing and insert it in
the backshell until fully seated.
4
Slide forward the strain relief collar and insert
it in the backshell, making sure that the
opposing protrusions fit inside the
corresponding grooves, as shown on the
illustration.
Note
Tightening collar
5
Threaded section
Tightening collar
10
Coat the thread section of the body/insulator
assembly with Loctite 271 compound
(manufactured by Henckel Japan, Ltd.) or
equivalent, tightening it with a torque
specified in the table 6.
Note
Seal bushing
Strain relief collar
Applicable connector
LF07WBJ-6S,6P,3S,3P
LF10WBJ-4S,4P,12S,12P
LF13WBJ-20S,20P,11S,11P
It is critical that the protrusions are inside the
corresponding grooves.
5
Verify that the Locktite 7649 primer
(or equivalent) on the threaded sections of the
backshell and tightening collar are dry.
Apply the Locktite 271 compound to the
tightening collar’s threaded section and attach
it to the backshell.
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHSLF
search
at www.hirose-connectors.com,
or contact
your Hirose
sales representative.
Series●Miniature
Waterproof
Shielded
Connectors
6
Operation
Illustration
No.
6
Tightening collar
6
Wrench width
Remove the connector from the solder
termination fixture, holding it by the locking
collar. Do not pull on the cable.
Shell size Tightening torque Wrench width
LF07
LF10
LF13
0.8N·m~1N·m
0.7N·m~1N·m
10mm
1 N·m~1.5 N·m
16mm
13mm
1. To maintain the water/dust protection performance and the cable clamp force, use a cable that is within the range of applicable diameter.
2. Consult HRS representative when using different cables.
■Cable Specifications (Reference)
Jacket
Shield
Insulator
Conductor
No. of contact
4 pos.
3 pos.
12 pos.
6 pos.
11 pos.
20 pos.
Material
Soft copper wire
Soft copper wire
Soft copper wire
Soft copper wire
Soft copper wire
Soft copper wire Soft copper wire
Size (mm)
Ø0.18
Ø0.26
Ø0.16
Ø0.16
Ø0.16
Ø0.26
Construction
20 /Ø0.18 mm dia. 20 /Ø0.26 mm dia. 7 /Ø0.16 mm dia.
7 /Ø0.16 mm dia.
7 /Ø0.16 mm dia.
26 /Ø0.26 mm dia. 7 /Ø0.16 mm dia.
Size (AWG)
AWG #20
AWG #16
AWG #26
AWG #26
AWG #26
AWG #16 AWG #26
Sectional area
–––––––
1.25
–––––––
0.14
0.14
1.25
0.14
Diameter (mm)
Ø0.98
Ø1.5
Ø0.48
Ø0.48
Ø0.48
Ø1.5
Ø0.48
Diameter (mm)
Ø1.5 (Standard)
Ø2.1 (Standard)
Ø0.88 (Standard) Ø0.9 (Standard)
Ø0.9 (Standard)
Ø2.1 (Standard) Ø0.95 (Standard)
Ø0.16
0.3
0.2
0.21
0.21
0.3
Material
Soft copper wire
Soft copper wire
Soft copper wire
Soft copper wire
Soft copper wire
Soft copper wire
Density
85%
80%
85%
80%
80%
80%
Diameter (mm)
Ø3.6
Ø5.5
Ø3.4
Ø4.2
Ø5.1
Ø6.7
Diameter (mm)
Ø5±0.2
Ø7.3±0.2
Ø5±0.2
Ø7.3±0.2
Ø8.7±0.2
Thickness (mm) 0.26
0.235
Ø8.7±0.2
11
Similar pages