Technical Data Sheet RF_35/09.14/6.2 Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG 4.3-10 Calibration Adaptor 64K121-K20S3 Jack/Jack All dimensions are in mm; tolerances according to ISO 2768 m-H Interface According to IEC 61169-54 Documents Application note AN001 “Calibration Services” Material and plating Connector parts Center conductor Outer conductor Body Dielectric Material CuBe CuBe Stainless steel PTFE Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Plating Gold, min. 1.27 µm, over nickel Silver, 3-6 µm Passivated Tel. : +49 8684 18-0 Email : [email protected] Page 1/3 Technical Data Sheet 4.3-10 Calibration Adaptor 64K121-K20S3 Jack/Jack Electrical data RF_35/09.14/6.2 Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG Frequency range Return loss DC to 6 GHz ≥ 36 dB, DC to 4 GHz ≥ 28 dB, 4 GHz to 6 GHz Mechanical data Mating cycles Maximum torque Recommended torque Gauge ≥ 100 5 Nm 2 Nm 3.10 mm to 3.25 mm General standard definitions For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour of this calibration standard. The different models, units, and terms used will depend on the VNA type and they will have to be entered into the VNA. All values are based on typical geometry and plating. Offset Zo / Impedance / Zo Offset Delay Length (electrical) / Offset Length Offset Loss Loss 50 Ω 189,466 ps 56,80 mm 2.50 GΩ/s 0,0411 dB / GHz Environmental data Operating temperature range1 Rated temperature range of use2 Storage temperature range + 20 °C to +26 °C 0 °C to +50 °C - 40 °C to +85 °C RoHS compliant 1 2 Temperature range over which these specification are valid. This range is underneath and above the operating temperature range, within the calibration adaptor is fully functional and could be used without damage. Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Tel. : +49 8684 18-0 Email : [email protected] Page 2/3 Technical Data Sheet 4.3-10 Calibration Adaptor 64K121-K20S3 Jack/Jack RF_35/09.14/6.2 Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG Declaration of calibration options Factory Calibration Standard delivery for this calibration standard includes a Factory Calibration. The Calibration Certificate issued reports individual calibration results, traceable to Rosenberger standards, national / international standards are not available. Model based standard definitions are reported in an Agilent/Keysight, Rohde & Schwarz and Anritsu compatible VNA format. Accredited Calibration Not available. For further, more detailed information see application note AN001 on the Rosenberger homepage. Calibration interval Recommendation 12 months Packing Standard Weight 1 pce in box 100 g/pce While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our products, we reserve the right to make changes judged to be necessary. Draft Date Approved Date Rev. Engineering change number Name Date Marcel Panicke 11.02.16 Markus Müller 11.02.16 a00 16-s064 Marcel Panicke 11.02.16 Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Tel. : +49 8684 18-0 Email : [email protected] Page 3/3