Rosenberger IEC61169-54 Calibration adaptor Datasheet

Technical Data Sheet
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
4.3-10
Calibration Adaptor
64K121-K20S3
Jack/Jack
All dimensions are in mm; tolerances according to ISO 2768 m-H
Interface
According to
IEC 61169-54
Documents
Application note
AN001 “Calibration Services”
Material and plating
Connector parts
Center conductor
Outer conductor
Body
Dielectric
Material
CuBe
CuBe
Stainless steel
PTFE
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Plating
Gold, min. 1.27 µm, over nickel
Silver, 3-6 µm
Passivated
Tel. : +49 8684 18-0
Email : [email protected]
Page
1/3
Technical Data Sheet
4.3-10
Calibration Adaptor
64K121-K20S3
Jack/Jack
Electrical data
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Frequency range
Return loss
DC to 6 GHz
≥ 36 dB, DC to 4 GHz
≥ 28 dB, 4 GHz to 6 GHz
Mechanical data
Mating cycles
Maximum torque
Recommended torque
Gauge
≥ 100
5 Nm
2 Nm
3.10 mm to 3.25 mm
General standard definitions
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this calibration standard. The different models, units, and terms used will depend on the VNA type and they
will have to be entered into the VNA. All values are based on typical geometry and plating.
Offset Zo / Impedance / Zo
Offset Delay
Length (electrical) / Offset Length
Offset Loss
Loss
50 Ω
189,466 ps
56,80 mm
2.50 GΩ/s
0,0411 dB / GHz
Environmental data
Operating temperature range1
Rated temperature range of use2
Storage temperature range
+ 20 °C to +26 °C
0 °C to +50 °C
- 40 °C to +85 °C
RoHS
compliant
1
2
Temperature range over which these specification are valid.
This range is underneath and above the operating temperature range, within the calibration adaptor is fully functional
and could be used without damage.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : [email protected]
Page
2/3
Technical Data Sheet
4.3-10
Calibration Adaptor
64K121-K20S3
Jack/Jack
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Declaration of calibration options
Factory Calibration
Standard delivery for this calibration standard includes a Factory Calibration. The Calibration Certificate issued
reports individual calibration results, traceable to Rosenberger standards, national / international standards
are not available. Model based standard definitions are reported in an Agilent/Keysight, Rohde & Schwarz and
Anritsu compatible VNA format.
Accredited Calibration
Not available.
For further, more detailed information see application note AN001 on the Rosenberger homepage.
Calibration interval
Recommendation
12 months
Packing
Standard
Weight
1 pce in box
100 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
Approved
Date
Rev.
Engineering change number
Name
Date
Marcel Panicke
11.02.16
Markus Müller
11.02.16
a00
16-s064
Marcel Panicke
11.02.16
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : [email protected]
Page
3/3
Similar pages