DYELEC DB202S Single phase 2.0amp surface mount glass passivated bridge rectifier Datasheet

DB201S THRU DB207S
SINGLE PHASE 2.0AMP SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER
Features
Glass passivated die construction
Low forward voltage drop
High current capability
High surge current capability
Designed for surface mount application
Plastic material-UL flammability 94V-0
DB-S
0.311(7.9)
0.043(1.1)
0.035(0.9 )
MIL-STD-202, Method 208
· Polarity: as marked on case
· Mounting position: Any
· Marking: type number
0.378(9.6)
0.0098 (0.25)
MAX 0.0079 (0.2)
· Case:DB-S, molded plastic
· Terminals: plated leads solderable per
~
0.402(10.2)
0.0059(0.15)
~
Mechanical Data
0.291(7.4)
0.240(6.1)
+
-
0.256(6.5)
·
·
·
·
·
·
0.329(8.35 )
0.313( 7.95)
0.098(2.50 )
0.083(2.10)
0.205(5.2)
· Lead Free: For RoHS / Lead Free Version
0.197(5.0)
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ ambient temperature unless otherwise specified.
Single Phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
SYMBOL DB201S DB202S DB203S DB204S DB205S DB206S DB207S UNITS
VRRM
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
VRWM
RMS Reverse Voltage
VRMS
Average Rectified Output Current (Note 1)@TC=100℃
IF(AV)
2.0
A
IFSM
60
A
100
200
400
600
800
1000
V
35
70
140
280
420
560
700
V
VDC
Non-Repetitive Peak Forward Surge Current 8.3ms
Single half sine-wave superimposed on rated load
(JEDEC Method)
I2t Rating for Fusing (t < 8.3ms)
Forward Voltage per element
50
I 2t
@IF=2.0A
14.94
A2s
VFM
1.0
V
Peak Reverse Current
@TA=25℃
At Rated DC Blocking Voltage @TA=125℃
IR
5.0
200
uA
Typical Junction Capacitance per leg (Note 2)
CJ
25
pF
RθJA
40
RθJL
15
TJ,TSTG
-55to+150
Typical Thermal Resistance per leg
Operating and Storage Temperature Range
℃/W
℃
2
Note:1. Mounted on glass epoxy PC board with 1.3mm solder pad.
2. Measured at 1.0 MHz and applied reverse voltage of 4.0V D.C.
version:02
1 of 3
www.dyelec.com
DB201S THRU DB207S
Fig. 2 Typical Forward Characteristics (per leg)
IF, INSTANTANEOUS FORWARD CURRENT (A)
I(AV), AVERAGE FORWARD RECTIFIED CURRENT (A)
Fig. 1 Output Current Derating Curve
2
1.99 5
1
0.5
0
0
40
80
120
10
1.0
0.1
TA = 25°C
Pulse Width = 300µs
0.01
0.2
160
60
40
20
TA = 25°C
Single Half Sine-Wave
Pulse Width =8.3ms
(JEDEC Method)
1.0
10
NUMBER OF CYCLES AT 60 Hz
Fig. 5
0.6
0.8
1.0
1.2
1.4
1.6
Fig. 4 Typical Reverse Characteristics (per element)
IR, INSTANTANEOUS REVERSE CURRENT (µA)
IFSM, PEAK FORWARD SURGE CURRENT (A)
Fig. 3 Maximum Peak Forward Surge Current (per leg)
0
0.4
VF, INSTANTANEOUS FORWARD VOLTAGE (V)
TC , CASE TEMPERATURE (°C)
100
TJ = 125°C
10
1.0
TJ = 25°C
0.1
0.01
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE (%)
Mounting Pad La yout
0.047 MIN.
(1.20 MIN.)
0.405 MAX.
(10.3 MAX.)
0.062 MIN.
(1.6 MIN.)
0.205 (5.2)
version:02
2 of 3
www.dyelec.com
DB201S THRU DB207S
Important Notice and Disclaimer
•Reproducing and modifying information of the document is prohibited without permission
from DIYI.
• DIYI reserves the right to make changes to this document and its products and
specifications at any time without notice. Customers should obtain and confirm the
latest product information and specifications before final design, purchase or use.
•DIYI disclaims any and all liability arising out of the application or use of
any product including damages incidentally and consequentially occurred.
•DIYI does not assume any and all implied warranties, including warranties of fitness for
particular purpose, non-infringement and merchantability.
Applications shown on the here in document are examples of standard use and
•
operation. Customers are responsible in comprehending the suitable use in particular
applications.
DIYI makes no representation or warranty that such applications will be suitable for the
specified use without further testing or modification.
•The products shown here in are not designed and authorized for equipments requiring high
level of reliability or relating to human life and for any applications concerning life-saving
or life-sustaining, such as medical instruments, transportation equipment, aerospace
machinery et cetera. Customers using or selling these products for use in such applications
do so at their own ris k andagree to fully indemnify DIYI for any damages resulting from such
improper use or sale.
•Since DIYI uses lot number as the tracking base, please provide the lot number for tracking
when complaining.
version:02
3 of 3
www.dyelec.com
Similar pages