OMRON G3VM-61B1

MOS FET Relays
G3VM-61B1/E1
Analog-switching MOS FET Relay for
High Switching Currents, with Dielectric
Strength of 2.5 kVAC between I/O.
• Upgraded G3VM-61 B/E Series.
• Switches minute analog signals.
• Leakage current of 1 mA max. when output relay is open.
■ Application Examples
Approval pending
• Measurement devices
• Security systems
Note:
• Amusement machines
The actual product is marked differently from the image
shown here.
■ List of Models
Contact form
SPST-NO
Terminals
Load voltage (peak value)
PCB terminals
60 VAC
Model
G3VM-61B1
Surface-mounting
terminals
Number per stick
Number per tape
50
---
---
1,500
G3VM-61E1
G3VM-61E1(TR)
■ Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G3VM-61B1
G3VM-61E1
7.12±0.25
7.12±0.25
6.4±0.25
6.4±0.25
7.62±0.25
7.62±0.25
0.8±0.25
+0.15
3.65 −0.25
+0.15
3.65 −0.25
Note: The actual product
is marked differently from the image
shown here.
1.2±0.15
0.5±0.1
2.54±0.25
2.5 min.
7.85 to 8.80
Weight: 0.38 g
Note: The actual product
is marked differently from the image
shown here.
4.0 +0.25
−0.2
1.0
min.
+0.1
0.25 −0.05
1.2±0.15
1.0 min.
10.0 max.
2.54±0.25
Weight: 0.38 g
■ Terminal Arrangement/Internal Connections (Top View)
G3VM-61B1
6
5
4
1
2
3
■ PCB Dimensions (Bottom View)
G3VM-61B1
2.54
Six 0.8-dia. holes
(0.61)
G3VM-61E1
6
5
4
1
2
3
■ Actual Mounting Pad Dimensions
(Recommended Value, Top View)
G3VM-61E1
2.54
2.54
2.54
8.3 to 8.8
(1.52)
(0.61)
(1.52)
1.3
1.5
10
G3VM-61B1/E1
G3VM-61B1/E1
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Input
Output
Symbol
Rating
Unit
Measurement Conditions
Note:
LED forward current
IF
50
mA
Repetitive peak LED forward
current
IFP
1
A
100 ms pulses, 100 pps
LED forward current reduction
rate
D IF/°C
-0.5
mA/°C
Ta ³ 25°C
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
°C
Output dielectric strength
VOFF
60
V
Continuous
load current
IO
500
mA
Connection A
Connection B
Connection A
Connection
A
1,000
D ION/°C
-0.5
Ta ³ 25°C
mA/°C
Connection
B
-0.5
Connection B
-10.0
Connection C
Tj
125
°C
Dielectric strength between input and
output (See note 1.)
VI-O
2,500
Vrms
Operating temperature
Ta
Connection temperature
Connection Diagram
1
6
2
5
3
4
1
6
2
5
3
4
1
6
2
5
3
4
Load
AC
or
DC
500
Connection C
ON current
reduction
rate
1. The dielectric strength between the input and
output was checked by applying voltage between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
AC for 1 min
-40 to +85
°C
With no icing or condensation
Storage temperature
Tstg
-55 to +125
°C
With no icing or condensation
Soldering temperature (10 s)
---
260
°C
10 s
Connection
C
Load
DC
Load
DC
■ Electrical Characteristics (Ta = 25°C)
Item
Input
Symbol
Minimum
Typical
Maximum
Unit
Measurement
conditions
Note:
LED forward voltage
VF
1.0
1.15
1.3
V
IF = 10 mA
Reverse current
IR
---
---
10
mA
VR = 5 V
Capacity between terminals
CT
---
30
---
pF
V = 0, f = 1 MHz
Trigger LED forward current
IFT
---
1.6
3
mA
IO = 500 mA
Maximum resistance
with output ON
RON
---
1
2
W
IF = 5 mA,
IO = 500 mA
Connection B
---
0.5
1
W
IF = 5 mA,
IO = 500 mA
Connection C
---
0.25
---
W
IF = 5 mA,
IO = 1,000 mA
ILEAK
---
---
1.0
mA
VOFF = 60 V
Capacity between I/O terminals
CI-O
---
0.8
---
pF
f = 1 MHz, Vs = 0 V
Insulation resistance
RI-O
1,000
---
---
MW
VI-O = 500 VDC,
RoH £ 60%
IF = 5 mA, RL = 200 W,
VDD = 20 V (See note 2.)
Output
Connection A
Current leakage when the relay is
open
Turn-ON time
tON
---
0.8
2.0
ms
Turn-OFF time
tOFF
---
0.1
0.5
ms
2. Turn-ON and Turn-OFF
Times
IF
1
6
2
4
RL
VDD
VOUT
IF
VOUT
10%
t ON
90%
t OFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Output dielectric strength
VDD
---
---
Operating LED forward current
IF
5
Continuous load current
IO
---
Operating temperature
Ta
- 20
---
Maximum
Unit
48
V
7.5
25
mA
---
500
mA
65
°C
■ Engineering Data
■ Safety Precautions
Load Current vs. Ambient Temperature
Refer to page 6 for precautions common to all G3VM models.
Load current (mA)
G3VM-61B1(E1)
1,200
Connection C
1,000
800
600
Connection A or connection B
400
200
0
−20
0
20
40
60
80
100
Ambient temperature (°C)
11