Astec LPS52 60 watt Datasheet

60 Watts
Total Power:
Input Voltage:
LPS50 Series
# of Outputs:
55-60 Watts
90-264 VAC
127-300 VDC
Single
Electrical Specs
Input
Input range
90-264 VAC (wide range)
127-300 VDC
47-440 Hz
<60 A peak @ 230 VAC,
cold start @ 25°C
<74 Watts
80-85% typical at full load
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 class B conducted
VDE 0878 PT3 class B conducted
Frequency
Inrush current
Input power
Efficiency
EMI RFI
Safety ground
leakage current
<0.5 mA @ 50/60 Hz,
264 VAC input for class I
<0.25mA@50/60Hz,
264 VAC input for class II
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Universal input
2” x 4” footprint
Remote sense
Overload and short circuit protection
Adjustable Output Voltage
High efficiency
High MTBF
Built in EMI filter (CISPR 22 Class B)
LED power good indicator
Input power <74 watts
Complies with EN61000-3-2
UL Class I approved
UL Class II available, consult factory
Output
Maximum power
60 W for convection (LPS52, 55W)
Adjustment range
Hold-up time
Overload protection
±20% minimum
10/20 ms 115/230 VAC Input line
Short circuit protection on all outputs.
Case overload protected @ 110-160% of
normal rating
30-50% above nominal output
Compensates for 0.5 V lead drop max.
Will operate without remote sense
connected. Reverse connection
protected.
Overvoltage protection
Remote sense
Environmental
Operating temperature: 0° to 50°C ambient derate
each output as 2.5% per degree from 50° to 70°C.
-20°C start up.
Storage temperature: -40°C to +85°C
Electromagnetic susceptibility:
designed to meetEN61000-4;
-2, -3, -4, -5, -6, -8, -11 Level 3
Humidity: Operating; non-condensing 10% to
95%RH
Safety
UL
CSA
NEMKO
TUV
CB
CE
CCC
UL 60950-1
CSA-C22.2 No. 60950-1
IEC/EN60950-1
EN60950-1
Certificate and report
LVD & EMC
GB4943
Vibration: IEC68-2-6 to the levels of IEC721-3-2
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions.
74
Americas: 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
rev 08.16.05
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44(1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
LPS50 Series
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Peak
Load1
Regulation2
Ripple
P/P (PARD)3
LPS52
LPS53
LPS54
LPS55
LPS58
5V
12 V
15 V
24 V
48 V
0A
0A
0A
0A
0A
11 A
5A
4A
2.5 A
1.25 A
12 A
5.4 A
4.4 A
2.75 A
1.35 A
±2%
±2%
±2%
±2%
±2%
50 mV
120 mV
150 mV
240 mV
480 mV
1. Peak current lasting <15 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
Pin Assignments
+24V
+24V
Common
Common
-Sense
+Sense
+48
+48
Common
Common
-Sense
+Sense
DC Outputs:
Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-58-0111
M1
C4
GRN/
YEL
+
~
~
R3
A
DB1
Q5
R3
VR1
GND
TP2
J4
L2
C32
24
C
TP1
T1
L3
C27
R1
D
4
SK2
F1
L1
C22
A
C5
1
1
C30
C2
Mating Connectors
AC Input:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-58-0111
VR1
(Output Voltage
Adjustment Pot) M2
1
3
B T2
SK1
T3.15A 2.5A
250VAC
F2
C1
C18 C9
Q6
R
TH
1
J3
22
2005
I
C17
3.75"
[95.3]
E
F
J1
J2
G
H
D2
1.75"
[44.5]
+15V
+15V
Common
Common
-Sense
+Sense
R26
+12 V
+12 V
Common
Common
-Sense
+Sense
+5 V
+5 V
Common
Common
-Sense
+Sense
DIP
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
T3.15A
2.5A
250VAC
LPS58
Line
Neutral
2.00"
[50.8]
LPS55
Line
Neutral
CN1
LPS54
Line
Neutral
3
LPS53
Line
Neutral
C
Connector LPS52
SK1-1
Line
SK1-3
Neutral
6
HTSK_SEC
D
J
LED1
Mounting Hole
Ø0.16"[4.0] 4 Places
4.00"
[101.6]
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02" (±0.5mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 VAC
input, 25°C unless otherwise stated.
6. Warranty: 1 year
7. Weight: .41lbs/.18kg
www.astecpower.com