SANYO LA1065M

Ordering number : EN3312
Monolithic Linear IC
LA1065M
2 Tuner Diversity Circuit
for Car FM Tuner
Overview
Package Dimensions
The LA1065M is a multi-functional IC for 2 tuner
diversity, and is capable of multi-path distortion detection
with high sensitivity.
unit: mm
3036B-MFP20
[LA1065M]
Functions
• Noise amplifier.
• Noise AGC circuit.
• Noise density comparison counting circuit.
• MAIN/SUB switching output.
• Weak electric field detection and antenna fixing circuit.
• Very strong electric field detection and antenna fixing
circuit.
• S meter voltage comparison circuit.
SANYO: MFP20
• AGC voltage output.
• S meter switch.
Specifications
Maximum Ratings at Ta=25°C
Parameter
Maximum supply voltage
Maximum flow-out current
Maximum flow-in current
Maximum applied voltage
Symbol
Conditions
Ratings
Unit
VCC max
I(4)
13
Pin 4
1
mA
I(5)
Pin 5
1
mA
I(6)
Pin 6
1
mA
I(9)
Pin 9
10
mA
I(12)
Pin 12
100
µA
I(7)
Pin 7
1
mA
I(8)
Pin 8
1
mA
V(15)
V(16)
V(17)
V(13)
V(14)
Ta=25°C
V
VCC
VCC
V
VCC
VCC
V
VCC
230
V
V
V
Allowable power dissipation
Pd max
Operating temperature
Topr
–30 to +80
mW
°C
Storage temperature
Tstg
–40 to +125
°C
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
93097HA (KT)/2200TA, TS (AF) No.3312-1/8
LA1065M
Operating Conditions at Ta=25°C
Parameter
Symbol
Recommended supply voltage
VCC
Operating voltage range
VCC op
Conditions
Ratings
Unit
8
V
7 to 12
V
Operation Characteristics at Ta=25°C, VCC=8V, f=100kHz sine wave
Parameter
Symbol
Conditions
Ratings
min
typ
max
Unit
Current drain
ICC
No input, not including pin 9 current
10
16
22
Pin 9 high-level voltage
V9H
1kΩ resistance between pin 9 and GND
5.0
6.0
7.5
V
Noise amplifier gain
Gsub
Vsub in=10mVrms pin 6 output
33
36
39
dB
Noise amplifier gain
mA
GV1
Vmain in=Vsub in=1mVrms pin 6 output
33
36
39
dB
GV2
Vmain in=Vsub in=100mV pin 6 output
6
10
14
dB
Noise detection sensitivity
NDS
Noise AGC off
8
12
16 mVrms
Noise count number
NCN
Difference between MAIN and SUB noise
Gate time 1
tG
Noise AGC off
4
500
620
740
µs
Repeat cycle of pin 4 waveform
Pin 6 voltage
V6
Vmain=Vsub=200mVrms
Pin 5 voltage
V5
Vsub=100mVrms
0.4
1.1
2.0
V
2.50
2.85
3.20
V
Strong field detection level
Medium field detection level
V17
0.7
1.1
1.5
V
V14
2.4
2.7
3.1
V
Weak field detection level
V13
S meter switch residual
V12
1.7
2.1
2.4
V
Input=0V
130 mVrms
Equivalent Circuit Block Diagram
No.3312-2/8
LA1065M
Sample Application Circuit
Unit (resistance : Ω, capacitance : F)
Operating Principle
(1) Multi-path distortion detection
• Overview
The LA1065M compares the high frequency noise elements in the S meter output from the two tuners to perform
multi-path distortion detection.
In addition to the higher harmonic distortion due to multi-path, the S meter noise includes pulse noise such as car
engine ignition noise, distortion elements due to modulation, phase noise and so on. All of this noise causes
misoperation of multi-path distortion detection.
The LA1065M resolves this problem through use of a unique noise count comparison method and the bottom
detection-type noise AGC.
• Noise count comparison
The causes of misoperation in a diversity reception system, which are pulse noise, distortion elements caused by
modulation, and phase noise, exist almost equally for MAIN and SUB. Also, the multi-path distortion to be
detected tends to exist on either the MAIN or SUB side.
The LA1065M uses an up/down counter to compare the noise counts of MAIN and SUB and detect multi-path.
• Bottom detection noise AGC
As described above, the S meter noise also exists on both MAIN and SUB sides, so when there is noise on both
sides, AGC goes on to prevent misoperation. On the other hand, when multi-path is generated and noise is on one
side or the other, AGC does not go on, enabling high sensitivity detection.
• A combination of the above methods is used to make the LA1065M capable of accurate multi-path detection.
No.3312-3/8
LA1065M
(2) S meter voltage comparison
For a medium field, the sound may be better if the antenna is switched by comparing S meter DC voltage rather
than using multi-path distortion detection when, for example, there is quite a difference (more than 10dB) in
antenna sensitivity between MAIN and SUB. On the LA1065M, a built-in comparator detects the medium field,
and compares S meter DC voltage in order to switch the antenna.
(3) Weak field detection and antenna fixing (MAIN)
There is a difference in antenna sensitivity between MAIN and SUB in a weak field, so sensitivity will be
insufficient even if switched to SUB.
The LA1065M uses a comparator, as shown below, to detect the weak field and fix the switching signal to the
MAIN side.
Unit (resistance : Ω)
(4) Very strong field detection and antenna fixing (SUB)
Interference such as I.M. (intermodulation) and cross modulation is generated in a very strong field. One
countermeasure is to use a PIN diode for antenna damping, but here the lower antenna gain on the SUB side is
utilized to fix the antenna to the SUB side when the electric field is strong. Also, with LA1065M, operation
returns to normal when multi-path is generated.
(5) AGC voltage output
As described in the section on bottom detection-type noise AGC, AGC voltage goes high when there is a lot of
noise on both MAIN and SUB sides. This voltage can be used to apply SNC, HCC and so on when the conditions
are poor for both MAIN and SUB.
(6) S meter switch
The LA1065M has built-in S meter switch so that SNC can be applied according to the MAIN and SUB switching
output. When the antenna is on MAIN, SNC is applied by MAIN side S meter voltage, and when it is on SUB, by
SUB side meter voltage.
(7) Logic section
The LA1065M operation is shown in th table below.
MAIN multiSUB multiMAIN S meter SUB S meter
path detection path detection
voltage
voltage
No noise
*
Strong field
With noise
With noise
*
Strong field
No noise
*
*
Weak field
*
MAIN>SUB
Medium field
*
*
MAIN<SUB
Medium field
*
*
No noise
*
Strong field
*
With noise
*
Strong field
No noise
*
Strong field
Large noise Medium noise
*
Strong field
Small noise Medium noise
* : Under any conditions
FE AGC voltage
Weak-medium field
Weak-medium field
*
Weak-medium field
Weak-medium field
Very strong field
Very strong field
Very strong field
Very strong field
MAIN/SUB
switching output
SUB side
MAIN side
MAIN side
MAIN side
SUB side
SUB side
MAIN side
SUB side
MAIN side
No.3312-4/8
LA1065M
Unit (resistance : Ω, capacitance : F)
Pin Function
Pin No.
Function
External
The AC component of 114kHz in IF, S meter
output is taken by the BPF and input to pin 1 (or
pin 20) by C coupling.
Notes
1
(20)
MAIN IN
SUB IN
2
(19)
H.P.F.
Highpass filter
3
(18)
AGC
Increase this capacitor's
value if antenna switching
tends to misoperate.
4
Be advised that the
LA1065M input impedance
changes with input and can
go to a minimum of 10kΩ.
Monostable
multi-vibrator
Continued on next page.
No.3312-5/8
LA1065M
Unit (resistance : Ω, capacitance : F)
Continued from preceding page.
Pin No.
Function
5
SUB noise
detection for
strong field
6
AGC voltage
output
7
8
Multi-path
detection mode
switching
External
Notes
DC voltage corresponding
to the LA1065M AGC can
be taken.
Mode switching table
Pin No.
Pin 7
Pin 8
9
MAIN/SUB
switching
signal output
GND
Count method for strong
field (4 counts)
S meter comparison for
medium field
VCC
S meter 114kHz level
comparison for strong field
Count method for medium field
(8 counts)
MAIN is high (6V typ when
resistance bet-ween pin 9
and GND is 1kΩ) and SUB
is low.
Continued on next page.
No.3312-6/8
LA1065M
Unit (resistance : Ω, capacitance : F)
Continued from preceding page.
Pin No.
Function
10
GND
11
VCC
12
S meter output
13
Comparator
for weak field
detection
14
Comparator
for medium
field detection
15
SUB S meter
input
16
MAIN S meter
input
17
F.E.
AGC input
External
Notes
S meter input must be
sufficiently integrated
before input.
Comparison level is set at
approximately 1V.
No.3312-7/8
LA1065M
No products described or contained herein are intended for use in surgical implants, life-support systems,
aerospace equipment, nuclear power control systems, vehicles, disaster/crime-prevention equipment and
the like, the failure of which may directly or indirectly cause injury, death or property lose.
Anyone purchasing any products described or contained herein for an above-mentioned use shall:
Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates,
subsidiaries and distributors and all their officers and employees, jointly and severally, against any
and all claims and litigation and all damages, cost and expenses associated with such use:
Not impose any responsibilty for any fault or negligence which may be cited in any such claim or
litigation on SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors or any of
their officers and employees jointly or severally.
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for volume production. SANYO believes information herein is accurate and reliable, but no guarantees
are made or implied regarding its use or any infringements of intellectual property rights or other rights of
third parties.
This catalog provides information as of September, 1997. Specifications and information herein are
subject to change without notice.
No.3312-8/8