UTC-IC TL1093

UNISONIC TECHNOLOGIES CO., LTD
TL1093
LINEAR INTEGRATED CIRCUIT
PROGRAMMABLE PRECISION
REFERENCE
„
DESCRIPTION
The UTC TL1093 is a three-terminal adjustable regulator with
a guaranteed thermal stability over applicable temperature ranges.
The output voltage may be set to any value between VREF
(approximately 2.5V) and 36 V with two external resistors. It
provides very wide applications, including shunt regulator, series
regulator, switching regulator, voltage reference and others.
„
FEATURES
*Programmable output Voltage to 36V.
*Low dynamic output impedance 0.2Ω.
*Sink current capability of 1.0 to 100mA.
*Equivalent full-range temperature coefficient of 50ppm/ °C
typical for operation over full rated operating temperature range.
„
1
SOT-89
Lead-free:
TL1093L
Halogen-free:TL1093G
ORDERING INFORMATION
Ordering Number
Normal
Lead Free
TL1093-AB3-R
TL1093L-AB3-R
Note: Pin Code: K: Cathode
A: Anode
TL1093L-AB3-R
Halogen Free
TL1093G-AB3-R
R: Reference
Package
SOT-89
Pin Assignment
1
2
3
K
A
R
Packing
Tape Reel
(1)Packing Type
(1) R: Tape Reel
(2)Package Type
(2) AB3: SOT-89
(3)Lead Plating
(3) G: Halogen Free, L: Lead Free Plating, Blank: Pb/Sn
www.unisonic.com.tw
Copyright © 2009 Unisonic Technologies Co., Ltd
1 of 5
QW-R103-045.A
TL1093
LINEAR INTEGRATED CIRCUIT
BLOCK DIAGRAM
CATHODE
REFERENCE
CATHODE (K)
REFERENCE (R)
2.5V VREF
ANODE(A)
ANODE
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 5
QW-R103-045.A
TL1093
„
LINEAR INTEGRATED CIRCUIT
ABSOLUTE MAXIMUM RATINGS (Operating temperature range applies unless otherwise specified)
PARAMETER
SYMBOL
RATINGS
UNIT
Cathode Voltage
VKA
37
V
Cathode Current Range(Continuous)
IKA
-100 ~ +150
mA
Reference Input Current Range
IREF
-0.05 ~ +10
mA
Power Dissipation
PD
800
mW
Operating Junction Temperature
TJ
+150
°C
Operating Ambient Temperature
TOPR
-40 ~ +85
°C
Storage Temperature
TSTG
-65 ~ +150
°C
Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Note:
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
„
RECOMMENDED OPERATING CONDITIONS
PARAMETER
Cathode Voltage
Cathode Current
„
SYMBOL
VKA
IKA
MIN TYP MAX UNIT
VREF
36
V
1
100 mA
ELECTRICAL CHARACTERISTICS (TC= 25°C, unless otherwise specified.)
PARAMETER
SYMBOL
TEST CONDITIONS
Reference Input Voltage
VREF VKA=VREF,IKA=10mA
Deviation of reference Input Voltage Over ΔVREF VKA=VREF,IKA=10mA
ΔT
temperature
0°C≤Ta≤70°C
ΔVREF
Ratio of Change in Reference Input
ΔVKA=10V~VREF
IKA=10mA
Voltage to the Change in Cathode Voltage ΔVKA
ΔVKA=36V~10V
Reference Input Current
IREF
IKA=10mA, R1=10kΩ, R2=∞
Deviation of Reference Input Current Over ΔIREF IKA=10mA, R1=10kΩ, R2=∞
ΔT
Full Temperature Range
Ta =full Temperature
Minimum Cathode Current for Regulation
IKA(MIN) VKA=VREF
Off-State Cathode Current
IKA(OFF) VKA=36V, VREF=0
VKA=VREF, IKA=1 to 100mA
Dynamic Impedance
ZKA
f≤1.0kHz
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN TYP MAX UNIT
2.470 2.495 2.520 V
4.5
17
mV
-1.0
-0.5
1.5
-2.7 mV/V
-2.0 mV/V
4
µA
0.4
1.2
µA
0.19
0.05
0.5
1.0
mA
µA
0.15
0.5
Ω
3 of 5
QW-R103-045.A
TL1093
LINEAR INTEGRATED CIRCUIT
■ TYPICAL CHARACTERISTICS
Cathode Current vs. Cathode Voltage
Cathode Current vs. Cathode Voltage
150
800
Ta=25°C
125 V =V
KA
REF
600
Cathode Current (μA)
Cathode Current (mA)
100
Ta=25°C
VKA=VREF
75
50
25
0
-25
-50
400
IKA(MIN)
200
0
-75
-100
-2
-1
0
1
2
-200
-2
3
-1
0
Cathode Voltage (V)
Change in Reference Input Voltage vs.
Cathode Voltage
IKA=100mA
Ta=25°C
-5
3
Ta=25°C
6
-10
-15
-20
-25
-30
-35
-40
2
Pulse Response
7
Input and Output Voltage (V)
Change In Reference Input Voltage (mV)
0
1
Cathode Voltage (V)
5
4
3
2
1
0
0
5
10
15
20
25
30
35
40
Cathode Voltage (V)
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
-1
-1
0
1
2
3
4
5
6
7
Time (µs)
4 of 5
QW-R103-045.A
TL1093
„
LINEAR INTEGRATED CIRCUIT
TEST CIRCUIT
VKA
INPUT
VKA
INPUT
IKA
IKA(OFF)
UTC
TL1093
UTC
TL1093
VREF
VKA=VREF×(1+R1/R2)+IREF×R1
For VKA≥VREF
For VKA=VREF
„
For IKA(OFF)
APPLICATION CIRCUIT
VIN
IN
UTC7805
VOUT
OUT
COMMON
R1
VREF
R2
UTC
TL1093
Output Control of a Three
-Terminal Fixed Regulator
Shutdown Regulator
VOUT
VIN
VIN
IOUT
VOUT
R1
VREF
R2
UTC
TL1093
VOUT=(1+R1/R2)×VREF
Minimum VOUT=VREF+5V
VOUT=(1+R1/R2)×VREF
VIN
VOUT=(1+R1/R2)×VREF
Higher-current Shunt Regulator
IOUT
VOUT
RCL
RS
RS
UTC
TL1093
UTC
TL1093
IOUT=VREF/RS
RS=VREF/RCL
Constant-current Sink
Current Limiting or Current Source
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
5 of 5
QW-R103-045.A