VECTRON TFS76

TFS 76.doc
Version 1.2
VI TELEFILTER
Filter Specification
01.03.2002
TFS 76
1/5
1. Measurement condition
Ambient temperature TA:
Input power level:
Terminating impedances at fc *):
23 °C
0 dBm
for input:
for output:
56 Ω // 28,5 pF
50 Ω // 0 pF
2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 76 is the minimum of the pass band attenuation amin. The minimum of the
pass band attenuation amin is defined as the insertion loss ae The centre frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 1 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the
reference frequency fc and the frequency response of the filter in the operating temperature range.
Data
typ. value
Insertion Loss
(Reference level)
ae
20,8
tolerance / limit
dB
max.
76,8 MHz ±
Centre Frequency at ambient temperature fC
Passband
PB
Relative Attenuation
arel
fc
75
kHz
fc ±
3,2 MHz
max.
0,7 dB
3,20 MHz
fc ±
3,20 MHz .......... fc ±
3,50 MHz
max.
1
dB
fc ±
3,65 MHz .......... fc ±
4,85 MHz
min.
1
dB
fc ±
4,85 MHz .......... fc ±
5,00 MHz
61
dB
min.
51
dB
fc -
71,8 MHz ......... fc -
5,00 MHz
65
dB
min.
50
dB
5,00 MHz ......... fc + 123,20 MHz
55
dB
min.
50
dB
°rms
max.
2
ns
max. 100
ns
µs
max.
3
µs
Operating Temperature Range
- 0 °C ... + 70
°C
Storage Temperature Range
- 20 °C ... + 80
°C
Deviation from Linear Phase in PB
Group Delay Ripple in PB
Average Group Delay in PB
Temperature Coefficient of Frequency
0,2
60
1,9
- 76
dB
dB
.......... fc ±
fc +
0,35
23
°rms
ppm/K
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
generated:
checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 76.doc
Version 1.2
VI TELEFILTER
Filter Specification
01.03.2002
TFS 76
2/5
3. Package
18
12,65 ±0,20
TFS 76
P10
year + week
2000
2001
2002
9
27,18 ±0,20
5,6±0,3
5,2 Max.
1 2
date code:
M
N
P
....
11 10
1
ø0,45±0,05
7,62 ±0,20
Pin Configuration
Input:
Input Return:
Output:
Output Return:
Ground:
1
18
10
9
2,11
2,54 ±0,20
20,32 ±0,20
4. 50 Ω matching network :
C1
Input
50 Ohm
1
10
Output
S AW
C2
50 Ohm
9
18
2,11
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 76.doc
Version 1.2
VI TELEFILTER
Filter Specification
TFS 76
01.03.2002
3/5
5. Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 76.doc
Version 1.2
VI TELEFILTER
Filter Specification
01.03.2002
TFS 76
4/5
7. Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS 76.doc
Version 1.2
VI TELEFILTER
Filter Specification
TFS 76
01.03.2002
5/5
8. History
Version
Reason of Changes
1.0
- generate specification according to customer requirements
1.1
1.2
Name
Pfeiffer
Date
14.06.2001
- typical values and terminating impedance added
- changing from nominal frequency attenuation related
to centre frequency attenuation related
- reducing max. insertion loss to 23 dB
Pfeiffer
20.02.2002
- changing package, matching configuration and terminating impedance
Pfeiffer
01.03.2002
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.