EPCOS B59701A0140A062

PTC thermistors as
limit temperature sensors
SMD, EIA case sizes 0402, 0603 and 0805
with ±3 °C and ±5 °C tolerance
Series/Type:
The following products presented in this data sheet are being withdrawn.
Ordering Code
B59401A0115A062
Substitute Product
Date of
Withdrawal
2010-05-28
Deadline Last
Orders
2010-08-31
Last Shipments
2010-11-30
For further information please contact your nearest EPCOS sales office, which will also support
you in selecting a suitable substitute. The addresses of our worldwide sales network are
presented at www.epcos.com/sales.
© EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Applications
DC/DC converters
Home appliances
Dimmers
Electronic ballasts
Temperature management in automotive electronics
Over-temperature protection of power transistors and power ICs
(e.g. in battery pack, notebook)
SMPS
Features
Thermistor chip with lead-free tinned terminations
Small size
Fast and reliable response
Suitable for reflow soldering only
RoHS-compatible
Lead-free (total Pb content <0.1%), for Tsense ≤125 °C, except B59602A... and B59603A...
UL approval to UL 1434 for B59601A... and B59604A... (file number E69802)
Options
Other Tsense values on request
Delivery mode
Blister tape (case size 0805) or cardboard tape (case sizes 0402 and 0603), 180-mm reel
with 8-mm tape, taping to IEC 60286-3
General technical data
Max. operating voltage
Operating temperature range
Please read Cautions and warnings and
Important notes at the end of this document.
(TA= 40 °C ... Tsense +15 K) Vmax
(V ≤ Vmax)
Top
Page 2 of 18
32
40/ Tsense +15
V DC
°C
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Electrical specifications and ordering codes
Tsense RR
°C
Ω
∆RR R
(Tsense ∆T)
%
kΩ
R
R
R
Ordering code
(Tsense +∆T) (Tsense +10 K) (Tsense +15 K)
kΩ
kΩ
kΩ
Case size 0402, standard series, ∆T = ±5 °C
105 470
±50 ≤ 4.7
≥ 4.7
115 470
±50 ≤ 4.7
≥ 4.7
Case size 0603, high-ohmic series, ∆T = ±5 °C
120 10000
±50 ≤ 4700
≥ 4700
130 10000
±50 ≤ 4700
≥ 4700
Case size 0603, standard series, ∆T = ±5 °C
75
470
±50 ≤ 4.7
≥ 4.7
85
470
±50 ≤ 4.7
≥ 4.7
95
470
±50 ≤ 4.7
≥ 4.7
105 470
±50 ≤ 4.7
≥ 4.7
115 470
±50 ≤ 4.7
≥ 4.7
125 470
±50 ≤ 4.7
≥ 4.7
135 470
±50 ≤ 4.7
≥ 4.7
Case size 0603, tight resistance tolerance series, ∆T = ±5 °C
70
110
±15 ≤ 1.1
≥ 1.1
55
470
±15 ≤ 4.7
≥ 4.7
85
470
±15 ≤ 4.7
≥ 4.7
105 470
±15 ≤ 4.7
≥ 4.7
Case size 0603, tight temperature tolerance series, ∆T = ±3 °C
75
470
±50 ≤ 4.7
≥ 4.7
470
±50 ≤ 4.7
≥ 4.7
≥ 15
85
95
470
±50 ≤ 4.7
≥ 4.7
≥ 40
105 470
±50 ≤ 4.7
≥ 4.7
≥ 40
115 470
±50 ≤ 4.7
≥ 4.7
≥ 40
125 470
±50 ≤ 4.7
≥ 4.7
≥ 40
±50 ≤ 4.7
≥ 4.7
≥ 40
135 470
Case size 0805, standard series, ∆T = ±5 °C
70
< 1000
≤ 5.7
≥ 5.7
≥ 401)
90
< 1000
≤ 5.5
≥ 13.3
≥ 40
100 < 1000
≤ 5.5
≥ 13.3
≥ 40
110 < 1000
≤ 5.5
≥ 13.3
≥ 40
120 < 1000
≤ 5.5
≥ 13.3
≥ 40
130 < 1000
≤ 5.5
≥ 13.3
≥ 40
140 < 1000
≤ 5.5
≥ 13.3
≥ 40
B59401A0105A062
B59401A0115A062
B59604A0085A062
B59604A0090A062
B59601A0075A062
B59601A0085A062
B59601A0095A062
B59601A0105A062
B59601A0115A062
B59601A0125A062
B59601A0135A062
B59602A0055B062
B59603A0055A062
B59603A0085A062
B59603A0105A062
B59601A0075B062
B59601A0085B062
B59601A0095B062
B59601A0105B062
B59601A0115B062
B59601A0125B062
B59601A0135B062
B59701A0070A062
B59701A0090A062
B59701A0100A062
B59701A0110A062
B59701A0120A062
B59701A0130A062
B59701A0140A062
Note:
In order to limit self heating effects the electrical power during measurement should be below
2 mW for case size 0402, below 4 mW for case size 0603 and below 6 mW for case size 0805.
1) R (Tsense +25 °C)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Dimensional drawings in mm
EIA case size 0402
Solder pad
EIA case size 0603
Solder pad
EIA case size 0805
Solder pad
Recommended maximum dimensions (mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 4 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Reliability data
Test
Electrical endurance,
constant at 85 °C
Standard
IEC 60738-1
Damp heat
IEC 60738-1
Rapid change
of temperature
IEC 60738-1
Vibration
IEC 60738-1
Shock
IEC 60738-1
Climatic sequence
IEC 60738-1
Bending test
EN 130000/4.35
Adhesive strength on
PCB
Please read Cautions and warnings and
Important notes at the end of this document.
Test conditions
Storage at Vmax /Top,max (Vmax)
T = 85 °C
Test duration: 1000 h
Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
T1 = Top,min (0 V), T2 = Top,max (0 V)
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, Test Na
Frequency: 10 to 55 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 × 2 h
Test according to IEC 60068-2-6, Test Fc
Acceleration: 390 m/s2
Pulse duration: 6 ms; 6 × 4000 pulses
Dry heat: T = Top,max (0 V)
Test duration: 16 h
Damp heat first cycle
Cold: T = Top,min (0 V)
Test duration: 2 h
Damp heat 5 cycles
Tests performed according to
IEC 60068-2-30
Components reflow-soldered to test board
Maximum bending: 2 mm
A shear force of 5 N is applied
perpendicular to the longitudinal axis of the
component which is soldered on PCB.
Page 5 of 18
∆R25/R25
< 25%
< 10%
< 10%
< 5%
< 5%
< 10%
< 10%
No visible
damage
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Characteristics (typical) for type A401
PTC resistance RPTC versus
PTC temperature TPTC
(measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Characteristics (typical) for type A601
PTC resistance RPTC versus
PTC temperature TPTC
(measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Characteristics (typical) for type A601
PTC resistance RPTC versus
PTC temperature TPTC
(measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Characteristics (typical) for type A602 and A603
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Characteristics (typical) for type A603
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Characteristics (typical) for type A604
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 11 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Characteristics (typical) for type A701
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 12 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Characteristics (typical) for type A701
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Cautions and warnings
General
EPCOS thermistors are designed for specific applications and should not be used for purposes
not identified in our specifications, application notes and data books unless otherwise agreed
with EPCOS during the design-in-phase.
Ensure suitability of thermistor through reliability testing during the design-in phase. The thermistors should be evaluated taking into consideration worst-case conditions.
Storage
Store thermistors only in original packaging. Do not open the package before storage.
Storage conditions in original packaging: storage temperature 25 °C ... +45 °C, relative humidity ≤75% annual mean, maximum 95%, dew precipitation is inadmissible.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environment with effect on function on long-term operation (examples given under operation precautions).
Use thermistor within the following period after delivery:
Through-hole devices (housed and leaded PTCs): 24 months
Motor protection sensors, glass-encapsulated sensors and probe assemblies: 24 months
Telecom pair and quattro protectors (TPP, TQP): 24 months
Leadless PTC thermistors for pressure contacting: 12 months
Leadless PTC thermistors for soldering: 6 months
SMDs in EIA sizes 3225 and 4032, and for PTCs with metal tags: 24 months
SMDs in EIA sizes 0402, 0603, 0805 and 1210: 12 months
Handling
PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs.
Components must not be touched with bare hands. Gloves are recommended.
Avoid contamination of thermistor surface during handling.
Soldering (where applicable)
Use rosin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Standard PTC heaters are not suitable for soldering.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 14 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Mounting
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting. Especially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of
the thermistor and the clamping contact.
The minimum force of the clamping contacts pressing against the PTC must be 10 N.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Operation
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal atmospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, ammonia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any
liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
Please read Cautions and warnings and
Important notes at the end of this document.
Page 15 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
Symbols and terms
A
Cth
f
I
Imax
IR
IPTC
Ir
Ir,oil
Ir,air
IRMS
IS
ISmax
LCT
N
Nc
Nf
P
P25
Pel
Pdiss
Rmin
RR
∆RR
RP
RPTC
Rref
RS
R25
R25,match
∆R25
T
t
TA
ta
TC
Area
Heat capacity
Frequency
Current
Maximum current
Rated current
PTC current
Residual currrent
Residual currrent in oil (for level sensors)
Residual currrent in air (for level sensors)
Root-mean-square value of current
Switching current
Maximum switching current
Lower category temperature
Number (integer)
Operating cycles at Vmax, charging of capacitor
Switching cycles at Vmax, failure mode
Power
Maximum power at 25 °C
Electrical power
Dissipation power
Minimum resistance
Rated resistance
Tolerance of RR
Parallel resistance
PTC resistance
Reference resistance
Series resistance
Resistance at 25 °C
Resistance matching per reel/ packing unit at 25 °C
Tolerance of R25
Temperature
Time
Ambient temperature
Thermal threshold time
Ferroelectric Curie temperature
Please read Cautions and warnings and
Important notes at the end of this document.
Page 16 of 18
Sensors
Limit temperature sensors, EIA sizes 0402, 0603 and 0805
tE
TR
Tsense
Top
TPTC
tR
Tref
TRmin
tS
Tsurf
UCT
V or Vel
VRMS
VBD
Vins
Vlink,max
Vmax
Vmax,dyn
Vmeas
Vmeas,max
VR
VPTC
Settling time (for level sensors)
Rated temperature
Sensing temperature
Operating temperature
PTC temperature
Response time
Reference temperature
Temperature at minimum resistance
Switching time
Surface temperature
Upper category temperature
Voltage (with subscript only for distinction from volume)
Root-mean-square value of voltage
Breakdown voltage
Insulation test voltage
Maximum link voltage
Maximum operating voltage
Maximum dynamic (short-time) operating voltage
Measuring voltage
Maximum measuring voltage
Rated voltage
Voltage drop across a PTC thermistor
α
∆
δth
τth
λ
Temperature coefficient
Tolerance, change
Dissipation factor
Thermal cooling time constant
Failure rate
Lead spacing (in mm)
Abbreviations / Notes
Surface-mount devices
* To be replaced by a number in ordering codes, type designations etc.
+ To be replaced by a letter
All dimensions are given in mm.
The commas used in numerical values denote decimal points.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 17 of 18
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap,
DSSP, MiniBlue, MiniCell, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube,
PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer,
SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending
in Europe and in other countries. Further information will be found on the Internet at
www.epcos.com/trademarks.
Page 18 of 18