JDSU LPR-530DWC1SA

AGILE OPTICAL SWITCHES
WaveReady™ 3000 Series Path and Equipment Protection Switch
LPR-530DWC1SA
Key Features
• Highly configurable to fit network applications
• Compact, simple to install, rugged, plug-and-play module
• Low power consumption (2 W maximum)
• Convection cooled, no fans
• Automatic switch-back
• User-definable thresholds
• Supports redundant -48 V supplies through the
DenseMount™ Shelf
Applications
• SMF fiber link protection
• Equipment protection
Compliance
• NEBS Level 3
• UL 60950 Third Edition
JDSU's Agile Optical Switch family provides the broadest portfolio of ROADM
solutions designed to match the requirements of major market segments. They
are the building blocks of Agile Optical Networks and provide the flexibility to
remotely reconfigure any or all wavelengths, thereby reducing time-to-service,
simplifying the network and streamlining planning and management. This results
in significant Opex and Capex reductions and faster time to revenue. In addition,
they enable the cost effective creation and deployment of more complex
network architectures.
The JDSU WaveReady 3000 series LPR-530DWC1SA path and equipment
protection module is a rugged, plug-and-play, bi-directional protection switch for
single mode fiber (SMF). It can be used for both equipment or fiber protection. A
typical application would be the protection of multi-channel links on SMF.
The LPR-530DWC1SA continuously monitors optical power on both its primary
and secondary links. If optical power on the primary link drops below a certain
threshold, the module switches traffic to the secondary link in less than 15 ms.
Two switching schemes are available. Manual operation allows for on-site or
remote switching from one link to the other. Automatic operation in window
switching mode allows users to control both the lower and upper level switch
activation points. An automatic switch-back feature resets the module to its
original configuration when the primary link power levels return to normal.
LPR-530DWC1SA features are highly configurable to fit most any network
application. Remote configuration, using TL1 commands, is available through a
WaveReady Communications Module and Ethernet interface on the WaveReady
chassis. Local configuration is available through an RS-232 craft interface on a
WaveReady Communications Module.
NORTH AMERICA : 800 498-JDSU (5378)
WORLDWIDE : +800 5378-JDSU
WEBSITE : www.jdsu.com
WAVEREADY 3000 SERIES
2
Typical Application
50/50 Splitter
Port C
Port D
Switch
Primary Path
Port A
Port E
Port B
Port F
Secondary Path
Port D
Port C
Primary Path
Port F
Port B
Switch
Port E
Port A
Secondary Path
50/50 Splitter
Specifications
Parameter
General Optical Characteristics
Wavelength for all ports
Switch Optical Characteristics
Insertion loss (including connectors)
Return loss (including connectors)
Switching time
Window switching mode
Reference power level range (RPLR)
RPL accuracy
Upper window switching range (UWSR)
(user programmable, settable in 1 dB increments)
Lower window switching range (LWSR)
(user programmable, settable in 1 dB increments)
Upper window switching limit (UWSL) (UWSL = RPL + UWSR)
Lower window wwitching limit (LWSL) (LWSL = RPL - LWSR)
Auto-switch-back hysteresis
Switch-back hold time
Switch type
Received power monitor accuracy (Received power range: -35 to 0 dBm)
Maximum received power level (no damage to the module)
Coupler Optical Characteristics
Insertion loss (including connectors)
Return loss (including connectors)
Electrical Characteristics
DC supply voltage (Through the DenseMount Shelf.
The DC power supply must be certified by a nationally
recognizedtest laboratory (NRTL) with -48 V SELV output.)
Power dissipation
Alarm relay signals
Minimum
Typical
Maximum
1290 to 1350 nm and 1463 to 1630 nm
>40 dB
-
-
<2 dB
<15 ms
≥-29 dBm
-
±2 dB
≥6 dB
≤-6 dBm
-
-
≥6 dB
-
≥-35 dBm
2 dB
3s
Latching
-
±2 dB
-
≤0 dBm
<15 dBm
>40 dB
-
<4 dB
-
-
-48 V
-
-
2W
Dry contact. Relay closed when alarm is active.
WAVEREADY 3000 SERIES
Continued
Specifications
Parameter
Physical Dimensions
Size (H x W x L)
DenseMount Shelf compliant (one slot)
Weight (approximate)
Environmental Characteristics
Operating ambient temperature
Storage temperature
Relative humidity (non-condensing)
Interface
Optical
Electrical
Craft
Minimum
Typical
Maximum
-
-
-
6.8 x 1.0 x 8.8 inches
(17.27 x 2.54 x 22.35 cm)
1.4 lbs (0.635 kg)
-
-5 °C
-40 °C
5%
-
70 °C
85 °C
95 %
Six SC/PC bulkheads, single-mode fiber (SMF)
96-pin connector (power, alarms, craft/remote interface)
TL1 interface through a Communications Module 100 and
DenseMount Shelf.
Six LEDs: power (CARD), automatic operation mode (AUTO),
primary path (PRI), secondary path (SEC), major alarm (MAJ),
minor alarm (MIN).
Two pushbutton switches:AUTO/MAN to select automatic or
manual operation mode and THR/PRI/SEC to set the switching
threshold or select the primary or secondary path in manual mode.
Relay, dry contact, MAJ (major) and MIN (minor). Relay closed
when alarm is active.
Front Panel
Alarms
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at
[email protected].
Sample: LPR-530DWC1SA
Associated Parts
Product Code
LPR-530DWC1SA
Product Code
COM-100ET001Y
10129126
Model
LightProtector 530
Description
Communications Module 100
DenseMount Shelf
All statements, technical information and recommendations related to the products herein are based upon information believed to be
reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any
inaccuracies. The user assumes all risks and liability whatsoever in connection with the use of a product or its application. JDSU reserves
the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, including
withdrawal at any time of a product offered for sale herein. JDSU makes no representations that the products
herein are free from any intellectual property claims of others. Please contact JDSU for more information. BrightSwitch, FiberShelf,
JDSU and the JDSU logo are trademarks of JDS Uniphase Corporation. Other trademarks are the property of their respective holders.
©2006 JDS Uniphase Corporation. All rights reserved. 10143046 Rev. 004 03/06 WAVEREADY3000.DS.CMS.AE
NORTH AMERICA : 800 498-JDSU (5378)
WORLDWIDE : +800 5378-JDSU
WEBSITE : www.jdsu.com