TI 6N136

6N135, 6N136, HCPL4502
OPTOCOUPLERS/OPTOISOLATORS
SOES022A – JULY 1986 – REVISED APRIL 1998
D
D
D
D
D
D
D
Compatible with TTL Inputs
High-Speed Switching . . . 1 Mbit/s Typ
Bandwidth . . . 2 MHz Typ
High Common-Mode Transient
Immunity . . . 1000 V/µs Typ
High-Voltage Electrical
Insulation . . . 3000 Vdc Min
Open-Collector Output
UL Recognized . . . File Number 65085
6N135, 6N136, OR HCPL4502 PACKAGE
(TOP VIEW)
NC
ANODE
CATHODE
NC
1
8
2
7
3
6
4
5
VCC
BASE/OPEN†
OUTPUT
GND
† Terminal 7 is BASE on the 6N135 and
6N136 and OPEN on the HCPL4502
NC – No internal connection
description
These high-speed optocouplers are designed for use in analog or digital interface applications that require
high-voltage isolation between the input and output. Applications include line receivers that require high
common-mode transient immunity, and analog or logic circuits that require input-to-output electrical isolation.
The 6N135, 6N136, and HCPL4502 optocouplers each consists of a light-emitting diode and an integrated
photon detector composed of a photodiode and an open-collector output transistor. Separate connections are
provided for the photodiode bias and the transistor-collector output. This feature, which reduces the transistor
base-to-collector capacitance, results in speeds up to one hundred times that of a conventional phototransistor
optocoupler.
The 6N135 is designed for TTL/CMOS, TTL/LSTTL, and wide-band analog applications.
The 6N136 and HCPL4502 are designed for high-speed TTL/TTL applications. The HCPL4502 has no base
connection.
schematic
ANODE
2
8
7
6
CATHODE
VCC
BASE: 6N135, 6N136
OPEN: HCPL4502
OUTPUT
3
5
GND
Copyright  1998, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
6N135, 6N136, HCPL4502
OPTOCOUPLERS/OPTOISOLATORS
SOES022A – JULY 1986 – REVISED APRIL 1998
absolute maximum ratings at 25°C free-air temperature (unless otherwise noted)†‡
Supply and output voltage range, VCC and VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 15 V
Reverse input voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 V
Emitter-base reverse voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 V
Peak input forward current (pulse duration = 1 ms, 50% duty cycle, see Note 1) . . . . . . . . . . . . . . . . . . 50 mA
Peak transient input forward current (pulse duration 1 µs, 300 Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A
Average forward input current(see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 mA
Peak output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 mA
Average output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 mA
Base current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 mA
Input power dissipation at (or below) 70°C free-air temperature (see Note 3) . . . . . . . . . . . . . . . . . . . . . 45 mW
Output power dissipation at (or below) 70°C free-air temperature (see Note 4) . . . . . . . . . . . . . . . . . . 100 mW
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 100°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
‡ JEDEC registered data for 6N135 and 6N136
NOTES: 1. Derate linearly above 70°C free-air temperature at the rate of 1.67 mA/°C.
2. Derate linearly above 70°C free-air temperature at the rate of 0.83 mA/°C.
3. Derate linearly above 70°C free-air temperature at the rate of 1.50 mW/°C.
4. Derate linearly above 70°C free-air temperature at the rate of 3.33 mW/°C.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
6N135, 6N136, HCPL4502
OPTOCOUPLERS/OPTOISOLATORS
SOES022A – JULY 1986 – REVISED APRIL 1998
electrical characteristics over operating free-air temperature range of 0°C to 70°C (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
6N135
MIN TYP†
MAX
1.6
1.7
6N136, HCPL4502
MIN
TYP†
MAX
UNIT
1.6
V
VF‡
Input forward voltage
IF = 16 mA,
∝VF
Temperature coefficient of
forward voltage
IF = 16 mA
VBR‡
Input breakdown voltage
IR = 10 µA,
TA = 25°C
VOL
Low level output voltage
Low-level
VCC = 4.5 V,
IF = 16 mA,
mA
IB = 0
IOL = 1.1 mA
High level output current
High-level
IF = 0,
IB = 0
0,
TA = 25°C
VCC = VO = 5.5 V
3
IOH‡
VCC = VO = 15 V
0.01
IOH
High-level output current
VCC = 15 V,
IF = 0,
VO = 15 V,
IB = 0
ICCH‡
Supply current, high-level
output
IO = 0,
IB = 0,
ICCH
Supply current, high-level
output
VCC = 15 V,
IF = 0,
TA = 25°C
VCC = 15 V,
IF = 0,
ICCL
Supply current, low-level
output
VCC = 15 V,
IF = 16 mA,
IO = 0,
IB = 0
hFE
Transistor forward current
transfer ratio
VO = 5 V,
IO = 3 mA
CTR‡
Current transfer ratio
VO = 0.4 V,
IB = 0,
See Note 5
CTR
Current transfer ratio
VCC = 4.5 V,
IF = 16 mA,
TA = 25°C,
VCC = 4.5 V,
IF = 16 mA,
See Note 5
rIO
Input-output resistance
VIO = 500 V,
See Note 6
TA = 25°C,
IIO‡
Input-output insulation
leakage current
VIO = 3000 V,
TA = 25°C,
See Note 6
t = 5 s,
RH = 45%,
Ci
Input capacitance
60
60
pF
Input-output capacitance
VF = 0,
f = 1 MHz,
f = 1 MHz
Cio
See Note 6
0.6
0.6
pF
TA = 25°C
– 1.8
– 1.8
5
mV/°C
5
0.1
V
0.4
V
IOL = 2.4 mA
0.1
0.4
500
3
500
nA
1
0.01
1
µA
50
µA
1
µA
2
µA
50
0.02
IO = 0,
IB = 0
VO = 0.5 V,
IB = 0,
1.7
1
0.02
2
40
100
(6N136
only)
100
7%
µA
40
18%
19%
5%
24%
15%
1012
Ω
1012
1
1
µA
† All typical values are at TA = 25°C.
‡ JEDEC registered data for 6N135 and 6N136
NOTES: 5. Current transfer ratio is defined as the ratio of output collector current IO to the forward LED input current IF times 100%.
6. These parameters are measured with terminals 2 and 3 shorted together and terminals 5, 6, 7, and 8 shorted together.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
6N135, 6N136, HCPL4502
OPTOCOUPLERS/OPTOISOLATORS
SOES022A – JULY 1986 – REVISED APRIL 1998
operating characteristics, VCC = 5 V, IF = 16 mA, TA = 25°C (unless otherwise noted)
PARAMETER
BW
Bandwidth (– 3 dB)
TEST CONDITIONS
RL = 100 Ω,
6N135
MIN
TYP
See Note 7
6N136, HCPL4502
MAX
MIN
2
TYP
MAX
2
UNIT
MHz
NOTE 7: Bandwidth is the range of frequencies within which the ac output voltage is not more than 3 dB below the low-frequency value.
switching characteristics at VCC = 5 V, IF = 16 mA, TA = 25°C
PARAMETER
tPLH†
tPHL†
dV
CM
(H)
dt
dV
CM
(L)
dt
Propagation delay
time low
time,
low-to-highto high
level output
Propagation delay
time high
time,
high-to-lowto low
level output
Common-mode
input transient
immunity,
high-level output
Common-mode
input transient
immunity,
low-level output
6N135
TEST CONDITIONS
MIN
RL = 4.1 kΩ,
See Figure 1
See Note 8,
RL = 1.9 kΩ,
See Figure 1
See Note 9,
RL = 4.1 kΩ,
See Figure 1
See Note 8,
RL = 1.9 kΩ,
See Figure 1
See Note 9,
∆VCM = 10 V,
RL = 4.1 kΩ,
See Figure 2
IF = 0,
See Notes 8 and 10,
∆VCM = 10 V,
RL = 1.9 kΩ,
See Figure 2
IF = 0,
See Notes 9 and 10,
∆VCM = 10 V,
See Notes 9 and 10,
RL = 4.1 kΩ,
See Figure 2
∆VCM = 10 V,
See Notes 9 and 10,
RL = 1.9 kΩ,
See Figure 2
6N136, HCPL4502
TYP
MAX
1
1.5
MIN
TYP
MAX
0.6
0.8
0.6
0.8
UNIT
µs
0.7
1.5
µs
1000
V/µs
1000
1000
V/µs
1000
† JEDEC registered data for 6N135 and 6N136
NOTES: 8. The 4.1-kΩ load represents one LSTTL unit load of 0.36 mA and a 6.1-kΩ pullup resistor.
9. The 1.9-kΩ load represents one TTL unit load of 1.6 mA and a 5.6-kΩ pullup resistor.
10. Common-mode transient immunity, high-level output, is the maximum rate of rise of the common-mode input voltage that does not
cause the output voltage to drop below 2 V. Common-mode input transient immunity, low-level output, is the maximum rate of fall
of the common-mode input voltage that does not cause the output voltage to rise above 0.8 V.
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
6N135, 6N136, HCPL4502
OPTOCOUPLERS/OPTOISOLATORS
SOES022A – JULY 1986 – REVISED APRIL 1998
PARAMETER MEASUREMENT INFORMATION
5V
Pulse
Generator
ZO = 50 Ω
tr = 5 ns
RL
Output
Input Current
Monitor
CL = 15 pF
(see Note A)
Open
100 Ω
GND
TEST CIRCUIT
Input
Current
IF
0V
5V
Output
Voltage
1.5 V
1.5 V
VOL
tPHL
tPLH
WAVEFORMS
NOTE A: CL includes probe and stray capacitance.
Figure 1. Switching Test Circuit and Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
6N135, 6N136, HCPL4502
OPTOCOUPLERS/OPTOISOLATORS
SOES022A – JULY 1986 – REVISED APRIL 1998
PARAMETER MEASUREMENT INFORMATION
IF
5V
RL
Output
A
B
Open
VFF
GND
Generator
TEST CIRCUIT
10 V
Generator
90%
dVCM
dt
90%
10%
10%
tr
0V
tf
Output
Switch at A: IF = 0
VOL
Switch at B: IF = 16 mA
VOLTAGE WAVEFORMS
Figure 2. Transient Immunity Test Circuit and Waveforms
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
8V
tr or tf
tr = 8 ns TYP
tf = 8 ns TYP
5V
Output
=
6N135, 6N136, HCPL4502
OPTOCOUPLERS/OPTOISOLATORS
SOES022A – JULY 1986 – REVISED APRIL 1998
TYPICAL CHARACTERISTICS
INPUT-DIODE FORWARD CURRENT
vs
FORWARD VOLTAGE
6N135
CURRENT TRANSFER CHARACTERISTICS
12
20
VCC = 5 V
TA = 25°C
11
18
10
16
I O – Output Current – mA
I F – Input-Diode Forward Current – mA
TA = 25°C
14
12
10
8
6
4
9
IF = 40 mA
IF = 35 mA
IF = 30 mA
8
7
6
5
4
IF = 25 mA
3
IF = 20mA
IF = 15mA
2
2
1
0
1.1
0
1.2
1.5
1.6
1.3
1.4
VF – Forward Voltage – V
1.7
IF = 10mA
0
2
IF = 5 mA
8
12
14
4
6
10
VO – Output Voltage – V
Figure 4
Figure 3
CURRENT TRANSFER RATIO (NORMALIZED)
vs
INPUT DIODE FORWARD CURRENT
CURRENT TRANSFER RATIO (NORMALIZED)
vs
FREE-AIR TEMPERATURE
1.1
1.1
CTR – Current Transfer Ratio (Normalized)
CTR – Current Transfer Ratio (Normalized)
1.2
6N136
HCPL4502
1
0.9
0.8
6N135
0.7
0.6
0.5
0.4
0.3
VCC = 5 V
VO = 0.4 V
TA = 25°C
Normalized to IF = 16 mA
0.2
0.1
0
1
2
4
7
10
16
20
40
70
100
VCC = 5 V
VO = 0.4 V
IF = 16 mA
6N135
6N136,
HCPL4502
1
0.9
0.8
0.7
0.6
– 60
– 40
IF – Input Diode Forward Current – mA
Figure 5
– 20
0
20
40
60
80
TA – Free-Air Temperature – °C
100
Figure 6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
7
6N135, 6N136, HCPL4502
OPTOCOUPLERS/OPTOISOLATORS
SOES022A – JULY 1986 – REVISED APRIL 1998
TYPICAL CHARACTERISTICS
DIFFERENTIAL CURRENT TRANSFER RATIO
vs
INPUT-DIODE QUIESCENT FORWARD CURRENT
HIGH-LEVEL OUTPUT CURRENT
vs
FREE-AIR TEMPERATURE
VCC = 5 V
VO = 5 V
IF = 0
4000
I OH – High-Level Output Current – nA
CTR(ac) – Differential Current Transfer Ratio – %
10,000
1000
400
100
40
10
4
1
0.4
0.1
– 75
– 50
–2 5
0
25
50
75
100
TA – Free-Air Temperature – °C
30
25
20
6N135
15
10
5
0
0
125
5
20
PROPAGATION DELAY TIME
vs
FREE-AIR TEMPERATURE
1.2
t PLH, t PHL– Propagation Delay Time – µ s
0
Frequency Response (Normalized)
15
Figure 8
FREQUENCY RESPONSE (NORMALIZED)
vs
FREQUENCY
–5
– 10
RL = 100 Ω
RL = 220 Ω
RL = 470 Ω
RL = 1 kΩ
– 15
– 20
– 25
IF = 16 mA
TA = 25°C
0.2
0.4
0.7 1
2
4
7
10
1.1
1
VCC = 5 V
IF = 16 mA
RL = 4.1 kΩ for 6N135
RL = 1.9 kΩ for 6N136
6N135 tPLH
0.9
0.8
6N135 tPHL
0.7
0.6
6N136 tPHL
HCPL4502
0.5
0.4
– 60
6N136 tPLH
HCPL4502
– 40
– 20
0
20
Figure 9
Figure 10
POST OFFICE BOX 655303
40
60
TA – Free-Air Temperature – °C
f – Frequency – MHz
8
10
IF – Input-Diode Quiescent Forward Current – mA
Figure 7
– 30
0.1
VCC = 5 V
VO = 0.4 V
TA = 25°C
6N136
HCPL4502
• DALLAS, TEXAS 75265
80
100
6N135, 6N136, HCPL4502
OPTOCOUPLERS/OPTOISOLATORS
SOES022A – JULY 1986 – REVISED APRIL 1998
MECHANICAL INFORMATION
9,91 (0.390)
9,49 (0.370)
8
7
6
5
1
2
3
4
Index Dot
C
L
7,87 (0.310)
7,37 (0.290)
C
L
6,60 (0.260)
6,10 (0.240)
1,78 (0,070)
1,14 (0.045)
0,89 (0.035) MIN
4,70 (0.185) MAX
105°
90°
8 Places
Seating Plane
Gauge Plane
0,76 (0.030)
0,00 (0.000)
0,84 (0.033) MIN
8 Places
0,51 (0.020)
MIN
3,17 (0.125) MIN
0,33 (0.013)
0,18 (0.007)
1,40 (0.055)
0,76 (0.030)
2,79 (0.110)
2,29 (0.090)
0, 457 ± 0,076
(0.018 ± 0.003)
8 Places
NOTES: A. JEDEC registered data. This data sheet contains all applicable registered data in effect at the time of publication.
B. All linear dimensions are given in millimeters and parenthetically given in inches.
Figure 11. Packaging Specifications
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
PACKAGE OPTION ADDENDUM
www.ti.com
8-Apr-2005
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
Package
Drawing
Pins Package Eco Plan (2)
Qty
6N135
OBSOLETE
PDIP
N
8
TBD
Call TI
Call TI
6N136
OBSOLETE
PDIP
N
8
TBD
Call TI
Call TI
HCPL4502
OBSOLETE
PDIP
N
8
TBD
Call TI
Call TI
Lead/Ball Finish
MSL Peak Temp (3)
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS) or Green (RoHS & no Sb/Br) - please check
http://www.ti.com/productcontent for the latest availability information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
Addendum-Page 1
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,
enhancements, improvements, and other changes to its products and services at any time and to discontinue
any product or service without notice. Customers should obtain the latest relevant information before placing
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms
and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI
deems necessary to support this warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for
their products and applications using TI components. To minimize the risks associated with customer products
and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process
in which TI products or services are used. Information published by TI regarding third-party products or services
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.
Use of such information may require a license from a third party under the patents or other intellectual property
of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for
such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that
product or service voids all express and any implied warranties for the associated TI product or service and
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Following are URLs where you can obtain information on other Texas Instruments products and application
solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
Telephony
www.ti.com/telephony
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Mailing Address:
Texas Instruments
Post Office Box 655303 Dallas, Texas 75265
Copyright  2005, Texas Instruments Incorporated