FAIRCHILD HLMP-3315

T-1 3/4 (5 mm)
SOLID STATE LAMPS
HIGH EFF. RED
HIGH EFF. RED
HLMP-3300
HLMP-3301
PACKAGE DIMENSIONS
HIGH EFF. RED
HIGH EFF. RED
STANDARD RED
HLMP-3315
HLMP-3316
FLV110
FEATURES
• Popular, general purpose lamps
• Wide and narrow viewing angle devices for direct
view or backlighting
0.200 (5.08)
0.180 (4.57)
• Solid state reliability
CL
0.040 (1.02)
• Sturdy leads for easy assembly
SEE
NOTES
DESCRIPTION
1.00 (25.4)
MIN
The HLMP-33XX series consists of high efficiency red T-1 3/4
lamps with a viewing angle of 35° or 65°. FLV110 is a low profile
standard red T-1 3/4 lamp with a diffused lens, providing a
viewing angle of 70°.
NOTES:
1. ALL DIMENSIONS ARE IN INCHES (mm).
0.050 (1.27)
0.100 (2.54)
Ø 0.230 (5.84)
0.050 (1.27)
REF.
0.100 (2.54)
REF.
0.023 (0.58)
0.017 (0.43)
SQ. TYP. (2X)
ABSOLUTE MAXIMUM RATING
FLAT DENOTES
CATHODE
2. TOLERANCES ARE ±.010” INCH UNLESS SPECIFIED.
3. AN EPOXY MENISCUS MAY EXTEND ABOUT .040”
(1 mm) DOWN THE LEADS.
4. DIMENSIONS X.
PACKAGE HEIGHT HLMP = .330 (8.38)/.350 (8.89)
FLV = .275 (6.98)/.295 (7.49)
5. FLV FLANGE HEIGHT = 0.040 (1.02)
0.060 (1.53)
(TA =25°C)
Parameter
HLMP33XX
FLV110
UNITS
Power Dissipation
135
135
mW
Average Forward Current
30
30
mA
90
90
mA
5
5
V
Peak Forward Current
(1 µS pulsewidth, 0.3% duty cycle)(FLV110 1 amp)
Reverse Voltage
Lead Soldering Time at 260° C
5
5
sec
Operating Temperature
-55 to +100
-55 to +100
°C
Storage Temperature
-55 to +100
-55 to +100
°C
 2001 Fairchild Semiconductor Corporation
DS300005
2/27/01
1 OF 4
www.fairchildsemi.com
T-1 3/4 (5 mm)
SOLID STATE LAMPS
ELECTRICAL / OPTICAL CHARACTERISTICS
Part Number
HLMP-3300
(TA =25°C)
HLMP-3301
HLMP-3315
HLMP-3316
FLV110
Luminous Intensity (mcd)
IF = 10mA
Minimum
2.0
4.0
12
20
0.8*
Typical
3.5
7.0
18
35
3.0*
3.0
3.0
3.0
3.0
2.0
Forward Voltage (V)
Maximum
Typical
Peak Wavelength (nm)
Condition
IF = 10mA
2.2
2.2
2.2
2.2
1.6
635
635
635
635
660
IF = 10mA
Reverse Voltage (V)
5
5
5
5
5
IR = 100µA
Viewing Angle (°)
65
65
35
35
70
IF = 10mA
* For FLV110 Test IF = 20mA
www.fairchildsemi.com
2 OF 4
2/27/01
DS300005
T-1 3/4 (5 mm)
SOLID STATE LAMPS
TYPICAL PERFORMANCE CURVES
(TA =25°C)
2.5
90
IF - FORWARD CURRENT (mA)
80
RELATIVE LUMNOUS INTENSITY
(NORMALIZED AT 20 mA)
AlGaAs
RED
70
HER
60
50
40
30
20
10
2.0
1.5
HER
1.0
AlGaAs
RED
0.5
0.0
0
1.0
2.0
3.0
4.0
5.0
0
5
20
25
30
50
IF - FORWARD CURRENT (mA)
1.0
AlGaAs RED
RELATIVE INTENSITY
15
Fig. 2 Relative Luminous Intensity vs.
DC Forward Current
Fig. 1 Forward Current vs. Forward Voltage
0.5
HER
0
40
HER, AlGaAs RED
30
20
10
0
500
550
600
650
700
750
20
40
60
85
100
Fig. 4 Current Derating Curve
Fig. 3 Relative Intensity vs. Peak Wavelength
2/27/01
0
TA - AMBIENT TEMPERATURE (˚C)
WAVELENGTH (nm)
DS300005
10
IF - DC FORWARD CURRENT (mA)
VF - FORWARD VOLTAGE (V)
3 OF 4
www.fairchildsemi.com
T-1 3/4 (5 mm)
SOLID STATE LAMPS
DISCLAIMER
FAIRCHILD SEMICONDUCTOR RESERVES THE THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE
TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT
ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT
DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE
RIGHTS OF OTHERS.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical
implant into the body,or (b) support or sustain life,
and (c) whose failure to perform when properly
used in accordance with instructions for use provided
in labeling, can be reasonably expected to result in a
significant injury of the user.
www.fairchildsemi.com
2. A critical component in any component of a life support
device or system whose failure to perform can be
reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
4 OF 4
2/27/01
DS300005