VECTRON EX-2090-DES-002S

EX-209
Hi-Reliability Evacuated Miniature Crystal Oscillator
EX-209
Features
Applications
• 16 pin Double Dip Package
• Ruggedized hybrid thick film construction
• Low Power Consumption
• Frequency Range: 10 MHZ to 40 MHZ
• Previous Model: EX-245
• Severe Environmental Conditions
Performance Specifications
Parameter
Min
Typ
Max
Units
Condition
Frequency Stabilities1
[10 to 20 MHz]
vs. operating temperature range
(referenced to +25°C)
-50
-75
-100
+50
+75
+100
ppb
ppb
ppb
0… +60°C
-20… +70°C
-40… +85°C
Initial tolerance for fixed frequency
Settability
vs. supply voltage change
vs. load change
-1.0
-0.2
-15
-15
+1.0
+0.2
+15
+15
ppm
ppm
ppb
ppb
fixed, no adjust
vs. aging / day
vs. aging / 1 year
vs. aging / 10 year (10 to <12 MHz)
vs. aging / 10 year (12 to <16 MHz)
vs. aging / 10 year (16 to 20 MHz)
-2
-200
-1000
-1500
-2000
+2
+200
+1000
+1500
+2000
ppb
ppb
ppb
ppb
ppb
after 7 days of operation
120
180
seconds
seconds
to ± 1ppm of final freq. @+25°C
to ± 100ppb of final freq. @+25°C
Warm-up Time2
VS ± 5%
Load ± 5%
Frequency Stabilities1
[>20 to 40 MHz]
vs. operating temperature range
(referenced to +25°C)
-75
-100
-150
+75
+100
-150
ppb
ppb
ppb
0… +60°C
-20… +70°C
-40… +85°C
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Performance Specifications
Parameter
Initial tolerance for fixed frequency
Settability
vs. supply voltage change
vs. load change
vs. aging / day
vs. aging / 1 year
vs. aging / 10 year
Min
Typ
Max
Units
Condition
-1.5
-0.3
-25
-25
+1.5
+0.3
+25
+25
ppm
ppm
ppb
ppb
fixed, no adjust
-3
-300
-3000
+3
+300
+3000
ppb
ppb
ppb
after 7 days of operation
120
180
seconds
seconds
to ± 1ppm of final freq. @+25°C
to ± 100ppb of final freq. @+25°C
Warm-up Time2
VS ± 5%
Load ± 5%
Supply Voltage (Vs)
Supply voltage (Standard)
4.75
5.0
Power Consumption
5.25
VDC
2.2
0.7
1.2
Watts
Watts
Watts
during warm-up
steady state @ +25°C
steady state @ -40°C
RF Output
HCMOS
Signal [Standard]
15
Load
pF
0.1
Signal Level (Vol)
Vdd
0.9
Signal Level (Voh)
Vdd
Rise/Fall Time
40
Duty cycle
+7
ns
(10-90%)
60
%
(Voh-Vol)/2
Sinewave
Signal [Option]
50
Load
ohm
Output Power (Standard)
0.0
+2.0
+4.0
dBm
50 ohm load
Output Power (Option)
+3.0
+5.0
+7.0
dBm
50 ohm load
Harmonics
-25
dBc
Spurious
-60
dBc
Frequency Tuning (EFC)
Tuning Range
Fixed OCXO; No adjust
Tuning Range
Sufficient to compensate for 10 years
aging
Vref
+4.0
+4.1
+4.2
VDC
EFC (0V to 4V)
source current 1 mA maximum
Additional Parameters [10 to 20 MHz]
1
Phase Noise (10 to 20 MHZ)
-100
-125
-140
-145
-145
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
10 Hz
100 Hz
1 kHz
10 kHz
10 kHz
Phase Noise3 (>20 to 40 MHZ)
-90
-115
-130
-140
-140
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
10 Hz
100 Hz
1 kHz
10 kHz
10 kHz
1
ppb/g
Test at 10g sine vibration at 100Hz
3
G-Sensitivity
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Performance Specifications
Parameter
Min
Typ
Max
Units
Condition
Environmental Conditions (Designed to meet)
• Radiation Tolerant (operating):
Active devices are selected from a family of product that is inherently
radiation tolerant to meet 100krad (SI) total dose
• Mechanical Shock (survive)***:
MIL-STD-202, Test Method 213, Condition E (1000G, 0.5msec)
• Vibration Random (survive)***:
MIL-STD-202, Test Method 214, Condition I-F (20Grms, 3 minutes/axis)
• Vibration Sine (survive)***:
MIL-STD-202, Test Method 204, Condition D (20Grms, 20 minutes/axis)
Note: *** Met by design, not tested
Screening Options
Ordering Code
S
B
Test Inspection
S-Level Screening
B-Level Screening
Nondestructive Bond Pull
MIL-STD-883
Method 2023
N/A
Internal Visual Per Mil-PRF55310 Requirement
Internal Visual Per Mil-PRF-55310
Requirement
Internal Visual Per Mil-PRF-55310
Requirement
Stabilization Bake
MIL-STD-883
Method 1008,
Condition C
150°C for 48hrs
MIL-STD-883
Method 1008,
Condition C
Thermal Shock
MIL-STD-883
Method 1011,
Condition A
0°C to 100°C for
15cycles
N/A
Temperature Cycling (1)
MIL-STD-883
Method 1010,
Condition A
-55°C to 85°C (2)
for 10cycles
MIL-STD-883
Method 1010,
Condition A
-55°C to 85°C (2)
for 10cycles
Constant Acceleration (1)
MIL-STD-883
Method 2001
1000g’s (3)
Y1 Only
MIL-STD-883
Method 2001
1000g’s (3)
Y1 Only
PIND
MIL-STD-883
Method 2020,
Condition B
10g peak at 60Hz
minimum
N/A
Electrical Test
Per Mil-PRF-55310 Requirement
Per Mil-PRF-55310 Requirement
Burn-in (1)
85°C (2) for 240hrs
85°C (2) for 240hrs
Radiographic
MIL-STD-883
Method 2012
N/A
150°C for 48hrs
Note:
(1) These test inspections deviate from screening requirements for class 2 oscillator in MIL-PRF-55310.
(2) The maximum operating and storage temperature of the EX-209 is +85°C. The EX-209 shall not be exposed to temperature higher
than +85°C at length of time.
(3) The design and construction of the EX-209 can withstand up to 1000g’s constant acceleration
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Outline Drawing / Enclosure
Dimensions in inches (mm)
Type A
Code
Height “H”
Pin Length “L”
0
0.35 (8.9 mm)
0.17
Pin Connections
1
EFC \ No Connect
2-4
No Connect
8
Ground (Case)
9
Output
13-14
No Connect
15
Vref \ No Connect
16
Supply Voltage Input
Recommended Reflow Profile
TEMPERATURE (oC)
220
183
150
60s
60-90s
45-60s
TIME (s)
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Ordering Information
EX - 209 0 - D A J - 002S - 10M0000000
Frequency
Product Family
EX: EMXO
Platform Code
Tuning Option (1st digit):
0: Fixed Frequecy
1: Electrical Tuning
Package
25 x 25 mm
Height
0: A0.35”
Output Power (2nd digit)
0: 0 dBm
1: +3 dBm
Supply Voltage
D: 5 Vdc
Stability Code (3rd digit)
0: ±50ppb
1: ±75ppb
2: ±100ppb
3: ±150ppb
RF Output Code
A: HCMOS
E: Sinewave
Screening Option (4th digit)
S: “S” Level screening, Swept Quartz
C: “B” Level screening, Swept Quartz
B: “B” Level screening, Un-Swept Quartz
E: “EM” Engineering Model , Un-Swept Quartz
P: Proof of Design “POD-Prototype” , Un-Swept Quartz
Temperature Range
E: -40°C to +85°C
J: -20°C to +70°C
S: 0°C to +60°C
Notes:
1. Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies.
2. Unless other stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25°C).
3. Phase noise degrades with increasing output frequency.
4. Subject to technical modification.
5. Contact factory for availability.
For Additional Information, Please Contact
USA:
Vectron International
267 Lowell Road
Hudson, NH 03051
Tel: 1.888.328.7661
Fax: 1.888.329.8328
Europe:
Vectron International
Landstrasse, D-74924
Neckarbischofsheim, Germany
Tel: +49 (0) 3328.4784.17
Fax: +49 (0) 3328.4784.30
Asia:
Vectron International
1F-2F, No 8 Workshop, No 308 Fenju Road
WaiGaoQiao Free Trade Zone
Pudong, Shanghai, China 200131
Tel: 86.21.5048.0777
Fax: 86.21.5048.1881
Disclaimer
Vectron International reserves the right to make changes to the product(s) and or information contained herein without notice. No liability is assumed as a result of their use or application.
No rights under any patent accompany the sale of any such product(s) or information.
Rev: 5/7/2009 daf
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com